DigiTRON + and DigiTRON e Controls & Instrumentation connectors
|
|
- Gwendoline Reed
- 6 years ago
- Views:
Transcription
1 DigiTRON and Controls & Instrumentation connectors DigiTRON Evolution The next generation DigiTRON subsea electrical connectors has arrived
2 DigiTRON Evolution The next generation DigiTRON connectors has arrived Design Test Manufacture Qualification Installation
3 The DigiTRON Evolution Siemens Subsea has an established global reputation for the manufacture and delivery marketleading subsea connector and measurement technology. The enhanced next generation DigiTRON connectors has arrived. Introducing and from Siemens Subsea. Backward compatability, refined enhancements and increased reliability make and the most technically advanced and reliable subsea connectors on the market. The Siemens Subsea product name is recognised throughout the global subsea oil and gas industry as a leader in the design, manufacture and installation reliable subsea mateable electrical and optical connection systems. Siemens Subsea products are marketleading, high integrity, subsea power and data connection systems. Combined with our sensors they fer a convenient integrated scope supply with our customers benefitting from a single source supply for complete jumper assemblies and flying leads. This gives the advantage a simplified supply chain coupled with a single warranty. 11 Way ROV REDU (Retrievable Electrical Distribution Unit) 4000 metres depth rating Contents Technical Specification...7 Termination Methods...8 DigiTRON Range Product Selection...10 ing System...12 ROV Connectors...14 Stab Plate Connectors...25 Diver Connectors...35 Subsea Cable...45 Junction Boxes...46 ROV Retrievable EDU...47 quatron Oil Tube...48 quatron Junction Boxes...49 quatron Isolated Chamber Junction Boxes...50 Harness ssemblies...51 Interface Drawings...52 Coon Modular Diagram...54 Junction Boxes, Penetrators & Splices...56 Glossary Terms...57 ftermarket Services
4 The DigiTRON Evolution The DigiTRON range subsea instrumentation connectors combines the many field proven features the Mini CE connector with the latest in design technology. DigiTRON benefits include faster lead times and improved flexibility. This is achieved by DigiTRON s modular design specification using fewer components. Technically, DigiTRON retains the highdensity pin configurations for more compact 7 and 12 way connectors. PEEK and Ultem moulded inserts and pins eliminate potential leak paths around the termination area, while new louvred contacts minimise contact resistance. DigiTRON connectors for ROV operation are considerably simpler, stronger and more compliant to avoid damage while mating. new debris seal gives positive indication successful mating. High integrity is ensured by pressure compensation, two completely independent oil chambers and builtin redundancy. DigiTRON connectors are rated at 1000V ac (pin to earth) and up to 40. They are primarily used for instrumentation and low power distribution. DigiTRON Range Highlights 4, 7 & 12 ways for deployment by ROV, stab plate or diver Up to 1000 subsea mating cycles in a heavily contaminated sand / silt environment 30 year design life Inhouse testing to 4000 metres DigiTRON Continuous Improvements Partial demate ability Sulphamic compatible Cutaway model a 4 way plug assembly EMC screening available (oil tube only) Best practices document Qualified to: NHT Rev 04H (Norsk Hydro) RSNØ00182 Rev 01 (Statoil) TD0153 (Statoil) TR1233 (Statoil) GP EP SPS 021 (Total) BP Compliant 4
5 The DigiTRON Evolution Technology Overview Controlled Environment (CE) Principle DigiTRON connectors are based around the unique and patented Controlled Environment (CE) Principle. This arrangement ensures the highest level integrity for long life and repeated subsea mating capability. The CE plug features an oilfilled primary diaphragm to prevent water ingress. Each electrical socket is further protected within an individual secondary oilfilled diaphragm Both diaphragms have individual seals, failure either seal would not compromise the connector s integrity Shuttle pins prevent water ingress or loss oil when the connector is not mated Insulated pins on the receptacle connector displace the shuttle pins during the mating process. The conductive tips the pins are wiped twice before making contact with the electrical socket 7 way pin & socket insert assemblies The whole assembly is pressure balanced to minimise stress within the sealing areas 4 way plug front end 7 way plug front end 12 way plug front end 7 way socket insert assembly Technical Philosophy 1 Use pressure balancing to minimise material stress. CE Principle Sequence Operations 2 Use modular systems to achieve maximum flexibility whilst utilising proven components. 3 Include at least one level redundancy on high integrity connectors. 4 Mechanical gland sealing avoids many problems associated with moulding to cable sheaths. 1 & plug prior to mating 2 pin engages with shuttle pin plug assembly 5 Ensure material compatibility and traceability the majority Siemens Subsea subsea connectors have a 30 year design life with no requirement for servicing. 3 pin enters first oil chamber the primary diaphragm and pushes back the shuttle pin 4 pin enters secondary diaphragm and makes full contact with plug socket 5
6 DigiTRON Evolution The enhanced, next generation DigiTRON connectors has arrived. Introducing and from Siemens Subsea. Backward compatability, refined enhancements and increased reliability make and the most technically advanced and reliable subsea connectors on the market. We have a history providing reliability where you need it most subsea. With over 110,000 connectors in service on over 400 projects worldwide, the DigiTRON range connectors provides trusted quality and long lasting reliability. We strive for reliability in everything we do. and low voltage subsea connectors now redefine not only Siemens Subsea but also the subsea connector market. These two pinnacle products are manufactured and tested at our headquarters in Great Britain where cutting edge technology and advanced proven testing methods come together to provide the level service and reliability you would expect from a world leader in subsea connectors. When reliability counts, count on our experience. The refined and enhanced DigiTRON connector What is a connector? connector is a DigiTRON connector with enhanced capabilities. Backward compatible with the existing DigiTRON range Fully qualified to operate at 4000 metres (13,123 feet) depth pressure at full differential Fully qualified for 30 years design life PD (Partial Discharge) 1.73Uo & 2.50Uo giving longterm integrity 1000 mate / demates (750 dry followed by 250 turbid at 4000 metres depth pressure) Fully machined connector body which removes the need for welding Paddle handle with increased versatility Ethernet Connector The market s first ethernet connector with all the functionality What is a connector? connector is a connector with ethernet capability. When would there be a need for a connector? Where there is a requirement for higher data rates for real time control. The benefit a connector is that it allows you to react quickly to real time subsea situations. Fully qualified to operate at 4000 metres (13,123 feet) depth pressure at full differential Qualified in compliance with IEEE and the SIIS level 3 document which includes traffic generator and cable analyser tests Harnesses up to 160 metres in length (including test harness) capable handling 100 Mbps full duplex data 4000 metres (13,123 feet) depth pressure Multiple harnesses mated together to create a total length up to 160 metres (including test harness), capable handling 100 Mbps full duplex data 4000 metres (13,123 feet) depth pressure vailable for 12 way connectors only. 6
7 and Technical Specification Electrical Specification Maximum working voltage (pin to earth) Maximum working voltage (pin to pin) Maximum working current Working current in air Typical contact resistance Typical pin to pin resistance (connectors only) Ethernet Specification Typical pin to pin resistance (harness) Maximum data rate <100 metres (including test harness) IEEE Cable analyser 4 way connector 7 way connector 12 way connector 1000V rms (1414V peak) 1000V rms (1414V peak) 1000V rms (1414V peak) 2000V rms (2828V peak) 2000V rms (2828V peak) 2000V rms (2828V peak) 3540 mps 2232 mps 2028 mps 18 mps 14 mps 11 mps <4 milliohms <4 milliohms <4 milliohms >100 Gigaohms >100 Gigaohms >100 Gigaohms 4 way connector 7 way connector 12 way connector >10 Gigaohms 100 Mbps Full duplex CT 5E Mechanical Specification 4 way connector 7 way connector 12 way connector Depth rating 4000 metres (13,123 feet) 4000 metres (13,123 feet) 4000 metres (13,123 feet) Test pressure 440 bar (6382 psi) 440 bar (6382 psi) 440 bar (6382 psi) Maximum conductor size (standard) 4 2 (12 awg) 4 2 (12 awg) 4 2 (12 awg) Maximum conductor size (with crimps and extended cable gland) 25 2 (4 awg) 25 2 (4 awg) 25 2 (4 awg) Storage temperature range 40 C to 70 C 40 C to 70 C 40 C to 70 C Working temperature range 5 C to 60 C 5 C to 60 C 5 C to 60 C Onshore testing temperature range 20 C to 50 C 20 C to 50 C 20 C to 50 C Oil Tube Specification 4 way connector 7 way connector 12 way connector Standard conductors within the oil tube Ethernet cable Oil type Raychem Spec 44, 1000V, ø2.06 (0.08 inch), 16awg CT 5E Dow Corning 200/ 1000 (silicone oil) ROV Mating 4 way connector 7 way connector 12 way connector Mating force <30 f (<66 lbf) <30 f (<66 lbf) <50 f (<110 lbf) Demating force f (53 79 lbf) f (53 79 lbf) f ( lbf) Maximum radial misalignment ±20 (±0.79 inch) ±20 (±0.79 inch) ±20 (±0.79 inch) Maximum angular misalignment ±20 ±20 ±20 Maximum rotational misalignment ±15 ±15 ±15 7
8 Termination Methods Cable Termination fter termination and helium pressure testing, the gland housing is filled with hydrophobic dielectric gel. When deployed, a diaphragm subjects the gel to ambient seawater pressure, preventing water ingress and minimising material stress. Termination sleeves over the solder cups provide the conductors with a continuous insulating layer cabletoconductor boot seals the gland cavity from the cable. This prevents water ingress from the spaces between the conductors in the event cable sheath damage The compression cable seal performs consistently even when assembled in difficult conditions Tolerance jumpers is: Jumper length <10 metres 0 / metres Jumper length >10 metres 0 / +2% nominal length. Cable gland Gland Size / Cable Sheath Capacity Gland Minimum Maximum size sheath Ø sheath Ø G G Gland Options Gland extension modules can be used to accoodate crimps and tailing wire where the cable conductors are larger than the solder cups (4 2 ). For details see page 27. Cable sealing / gripping components Some configurations armoured cables can be terminated using armour termination modules. Please contact our Customer Support Department for more details. 10 DigiTRON connectors with standard cable glands 8
9 Termination Methods Oil Tube Termination Oilfilled quatron hose containing a number sheathed conductors can be used as an alternative to cable and glands. Connectors and oil tube are supplied as a complete harness. Pressure compensation is provided by the flexibility the tube Short oil tube jumpers are significantly simpler and less expensive than cable equivalents Oil tube termination Jumpers are available from a minimum length 1 metre to a maximum length 200 metres (excluding ethernet) Complex quatron hose harnesses can be constructed from connectors, tee pieces and junction boxes Tolerance jumpers is: Jumper length <10 metres 0 / metres Jumper length >10 metres 0 / +2% nominal length. Bulkhead Termination Bulkhead mounted connectors are used where a disconnectable interface is required at the boundary an environmentally sealed enclosure. Example applications include: subsea control modules, junction boxes and subsea power distribution modules. DigiTRON connectors for quatron oil tube Rear view a bulkhead connector with termination sleeves 9
10 and Product Selection This catalogue describes the standard connectors within the and range. Standard connectors are generally available at shorter lead times than less coon or bespoke connectors. Nonstandard configurations include: ngled cable / hose entry Extended glands to accoodate crimps facilitating termination to conductors bigger than 4 2 Multi cable / hose entry or? and plug connectors contain electrical sockets (female) protected by pressure balanced dielectric fluid. connectors contain pin inserts (male). s are inserted into receptacles hence their respective names. The choice between plug and receptacle is usually dictated by system configuration. There are three primary considerations: 1 If a voltage is to be applied to the connector whilst unmated, then a plug must be used. s must NEVER be live whilst unmated. 2 connector pins must not be left exposed to seawater. The advised maximum cumulative exposure over the life the system is 28 days, although some pin deterioration may occur in a shorter period. duy plug connector should be used wherever practical. Inline Connector () Inline plug connectors are fitted with socket contacts within an oilfilled environment and are terminated to a segment cable or oil tube. Inline Connector (B) Inline receptacle connectors are fitted with male pin contacts and are terminated to a segment cable or oil tube. When mated, the receptacle's pins are protected by the plug's dielectric fluid. The use duy connectors is advised if the pins on receptacles are likely to be exposed to seawater for any significant period. The advised maximum cumulative exposure over the life the system is 28 days, although some pin deterioration may occur in a shorter period. Bulkhead Connectors (G&H) Bulkhead connectors are used where a disconnectable interface is required at the boundary an environmentally sealed enclosure. pplications include oilfilled subsea control modules, junction boxes and instrument housings. The environmental seal is achieved by face and barrel 'O' rings. Solder cups are provided at the inboard side the connector for enduser termination. Inboard tails and / or termination sleeves can be specified at time order. 3 Some system designers prefer to use plug connectors (the more complicated component) on recoverable equipment. Connector End Views 4 way 7 way 12 way
11 and Product Selection Duy Connectors Fullfunction duy connectors are similar to inline connectors with a blank backshell replacing the cable gland or oil tube adaptor. Duies can be supplied with three distinct wiring configurations: 1 Open circuit. 2 Specified contacts shorted. 3 Specified contacts wired together with resistors. Wiring and resistor requirements are specified at time order. Duy / Shorting / Parking (M) The three principal uses for duy / shorting / parking receptacles are: 1 To provide a loop across the sockets a plug connector for subsea testing e.g. monitoring the condition an umbilical during deployment. 2 Somewhere to fix (park) a spare plug on a subsea installation. 3 To prevent marine growth and sand / silt deposits on an unmated plug. Duy / Shorting / Parking (L) There are four principal uses for duy plugs: 1 To mechanically and electrically protect the pins on a receptacle that might otherwise be exposed to seawater. 2 To provide a loop across the pins a receptacle connector for subsea test purposes e.g. monitoring the condition an umbilical during deployment. 3 To prevent marine growth and sand / silt deposits on an unmated receptacle. 4 Somewhere to fix (park) a spare receptacle on a subsea installation. Protective Caps (P&R) The use black acetal caps is recoended to protect connectors during transport and storage prior to subsea deployment. Test s and s (T) Test plugs and receptacles are used for costeffective factory testing a system without risk damage to the goldplated connector contacts. Notes: Please note letter in brackets e.g. () refers to the type connector (item 3) on pages 12 & 13. Wiring and resistor requirements are specified at time order. Connector End Views 11
12 ing System BROV10001BQG10MC04SVT CONNECTOR FMILY Indicates the connector family: BROV: ROV mated BDIV: Diver mated BST: Stab Plate mated SERIES Indicates the size (series) within the DigiTRON range and which insert they can accoodate: 10: 4 way Mini CE compatible inserts & 7 way high density inserts 20: 12 way high density inserts TYPE CONNECTOR Indicates the type connector as follows: : connector (socket contacts) B: connector (pin contacts) G: Flange mounted bulkhead receptacle connector (pin contacts) H: Flange mounted bulkhead plug connector (socket contacts) L: Duy plug connector (socket contacts) M: Duy receptacle connector (pin contacts) P: Protective cap for plug R: Protective cap for receptacle T: Test connector TERMINTION Indicates the type termination: G10: 10 gland G20: 20 gland EGxx: Extended gland Gxx: Gland with armour termination GxxB: Bend restrictor DB: quatron / quatron +* ( 0.5" NB) Oil Tube DC: quatron / quatron +* (0.75" NB) Oil Tube F: 3 0.5" NB 4 " 16 JIC fitting H: 0.75" NB 1 " 12 JIC fitting Indicates the contact insert density: MC: HD: NUMBER WYS Mini CE compatible High density pin configuration Indicates the number ways: 04: 4 Way 07: 7 Way 12: 12 Way CONTCT Indicates the type contact: S: Socket P: Pin 1 16 CONTCT INSERT DENSITY 4 The number iediately following the connector type distinguishes different variations represent different configurations plug connector for a particular shell size (series). MTERIL Indicates the material: : Stainless Steel (UNS S31603) BQ: Super Duplex Stainless Steel (UNS S32550) C: Black cetal CD: White cetal 9 ROV HNDLES Suffix indicates ROV handle: HP: Horizontal Paddle VT: Vertical T Bar HT: Horizontal T Bar VF: Vertical Fishtail HF: Horizontal Fishtail XY: XYZ Handle * quatron + to be available in
13 ing System EROV10001BQG10HD12SVT CONNECTOR FMILY 1 5 Indicates the connector family: TERMINTION Indicates the type termination: EROV: EDIV: EST: ROV mated Diver mated Stab Plate mated G10: 10 gland G20: 20 gland DC: quatron / quatron +* (0.75" NB) Oil Tube H: " NB 16 " 12 JIC fitting 2 SERIES Indicates the size (series) within the DigiTRON range and which insert they can accoodate: 6 CONTCT INSERT DENSITY Indicates the contact insert density: 20: 12 way high density inserts HD: High density pin configuration 3 TYPE CONNECTOR Indicates the type connector as follows: : connector (socket contacts) B: connector (pin contacts) G: Flange mounted bulkhead receptacle connector (pin contacts) H: Flange mounted bulkhead plug connector (socket contacts) L: Duy plug connector (socket contacts) refer to M: Duy receptacle connector refer to P: Protective cap for plug R: Protective cap for receptacle T: Test connector The number iediately following the connector type distinguishes different variations represent different configurations plug connector for a particular shell size (series) NUMBER WYS Indicates the number ways: 12: 12 Way CONTCT Indicates the type contact: S: Socket P: Pin ROV HNDLES Suffix indicates ROV handle: HP: VT: HT: VF: HF: XY: Horizontal Paddle Vertical T Bar Horizontal T Bar Vertical Fishtail Horizontal Fishtail XYZ Handle 4 MTERIL Indicates the material: : Stainless Steel (UNS S31603) BQ: Super Duplex Stainless Steel (UNS S32550) * quatron + to be available in
14 ROV Connectors ROV (Remotely Operated Vehicle) Deployment Large primary catchment area and built in compliance facilitate mating in difficult conditions ROV Connectors can cope with considerable misalignment during the initial stages mating but alignment is ensured before the pins meet the seals (Please refer to page 7 ROV Mating in the Technical Specification) Straight push / pull operation facilitated by the snap ring Manufactured from Super Duplex Stainless Steel (UNS S32550) for improved strength and corrosion resistance and giving a 30 year design life ROV Notes 1 4 way DigiTRON ROV connectors are compatible with 4 way Mini CE ROV connectors. ROV compliantly mounted receptacle 2 7 and 12 way DigiTRON ROV connectors utilise highdensity inserts and are NOT Mini CE compatible. 3 Siemens Subsea strongly recoend that ROV connectors are isolated from CP systems to minimise calcareous growth. 4 The use duy connectors is advised if the pins on receptacles are likely to be exposed to seawater. The advised maximum cumulative exposure over the life the connector is 28 days, although some pin deterioration may occur in a shorter period. ROV bulkhead mounted plug & receptacle Two views ROV flying plug with machined backshell and enhanced paddle handle for quatron oil tube 14
15 ROV Connectors ROV Connectors ROV Connectors ROV Connectors ROV Connectors ROV Connectors ROV Connectors Page 17 RECEPTCLE ROV FLYING FOR CBLE (001) ROV FLYING RECEPTCLE FOR CBLE (B001) Page 17 ROV COMPLINTLY MOUNTED FOR CBLE (002) ROV COMPLINTLY MOUNTED RECEPTCLE FOR CBLE (B002) ROV COMPLINTLY MOUNTED FOR CBLE (005) 90 ROV COMPLINTLY MOUNTED RECEPTCLE FOR CBLE (B005) ROV FLYING FOR QUTRON OIL TUBE (003) ROV FLYING RECEPTCLE FOR QUTRON OIL TUBE (B003) ROV COMPLINTLY MOUNTED FOR QUTRON OIL TUBE (004) ROV COMPLINTLY MOUNTED RECEPTCLE FOR QUTRON OIL TUBE (B004) ROV COMPLINTLY MOUNTED FOR QUTRON OIL TUBE (006) 90 ROV COMPLINTLY MOUNTED RECEPTCLE FOR QUTRON OIL TUBE (B006)
16 ROV Connectors ROV Connectors ROV Connectors Page ROV BULKHED MOUNTED (H001) ROV FLYING DUMMY (L001) ROV FIXED DUMMY (L002) RECEPTCLE ROV BULKHED MOUNTED RECEPTCLE (G001) ROV FLYING DUMMY RECEPTCLE (M002) ROV FIXED DUMMY RECEPTCLE (M004) Page ROV COMPLINTLY MOUNTED DUMMY (L003) ROV COMPLINTLY MOUNTED DUMMY RECEPTCLE (M003) ROV Connectors 22 ROV PRKING (L004) ROV PRKING RECEPTCLE (M001) ROV Connectors 23 MNULLY OPERTED PROTECTIVE CP FOR ROV RECEPTCLE (R001) ROV OPERTED PROTECTIVE CP FOR RECEPTCLE (R002) MNULLY OPERTED PROTECTIVE CP FOR ROV (P001) ROV OPERTED PROTECTIVE CP FOR (P002) 23 ROV Connectors ROV TEST (T001) ROV TEST RECEPTCLE (T002) ROV Connectors 16
17 ROV Connectors ROV FLYING CONNECTORS FOR CBLE RECEPTCLE Gland Cable Ø 10 4 G10 8 to BROV10001BQG10MC04S 10 7 G10 8 to BROV10001BQG10HD07S G20 23 to BROV20001BQG20HD12S 10 4 G10 8 to BROV10B001BQG10MC04P 10 7 G10 8 to BROV10B001BQG10HD07P G20 23 to BROV20B001BQG20HD12P ROV series [10 / 20] flying plug/receptacle with [4 / 7 / 12] pins/sockets and size [10 / 20] cable gland. ROV series 20 flying plug /receptacle with 12 pins/sockets and size [10 / 20] cable gland. EROV20001BQG20HD12S EROV20B001BQG20HD12P ROV COMPLINTLY MOUNTED CONNECTORS FOR CBLE Compliant Mount Compliant Mount RECEPTCLE Gland Cable Ø Flange Ø Interface Drg No G10 8 to T BROV10002BQG10MC04S 10 7 G10 8 to T BROV10002BQG10HD07S 10 4 G20 23 to T BROV10002BQG20MC04S 10 7 G20 23 to T BROV10002BQG20HD07S G20 23 to T BROV20002BQG20HD12S EROV20002BQG20HD12S 10 4 G10 8 to T BROV10B002BQG10MC04P 10 7 G10 8 to T BROV10B002BQG10HD07P 10 4 G20 23 to T BROV10B002BQG20MC04P 10 7 G20 23 to T BROV10B002BQG20HD07P G20 23 to T BROV20B002BQG20HD12P EROV20B002BQG20HD12P ROV series [10 / 20] compliantly mounted plug/receptacle with [4 / 7 / 12] pins/sockets and size [10 / 20] cable gland. ROV series 20 compliantly mounted plug/receptacle with 12 pins/sockets and size [10 / 20] cable gland. 17
18 ROV Connectors 90 ROV FLYING CONNECTORS FOR CBLE Compliant Mount Compliant Mount RECEPTCLE Gland Cable Ø Flange Ø Interface Drg No G10 8 to T BROV10005BQG10MC04S 10 7 G10 8 to T BROV10005BQG10HD07S G10 8 to T BROV20005BQG10HD12S 10 4 G20 23 to T BROV10005BQG20MC04S 10 7 G20 23 to T BROV10005BQG20HD07S G20 23 to T BROV20005BQG20HD12S 10 4 G10 8 to T BROV10B005BQG10MC04P 10 7 G10 8 to T BROV10B005BQG10HD07P G10 8 to T BROV20B005BQG10HD12P 10 4 G20 23 to T BROV10B005BQG20MC04P 10 7 G20 23 to T BROV10B005BQG20HD07P G20 23 to T BROV20B006BQG20HD12P ROV series [10 / 20] 90 flying plug/receptacle with [4 / 7 / 12] pins/sockets and size [10 / 20] cable gland. ROV series flying plug/receptacle with 12 pins/sockets and size [10 / 20] cable gland. EROV20005BQG10HD12S EROV20006BQG20HD12S EROV20B005BQG10HD12P EROV20B005BQG20HD12P 18
19 ROV Connectors ROV FLYING CONNECTORS FOR QUTRON OIL TUBE Please Note: connectors shown RECEPTCLE Hose internal Ø Hose outside Ø Hose Code DB BROV10003BQDBMC04S DB BROV10003BQDBHD07S DB BROV20003BQDBHD12S DB BROV10B003BQDBMC04P DB BROV10B003BQDBHD07P DB BROV20B003BQDBHD12P ROV series [10 / 20] flying plug/receptacle with [4 / 7 / 12] pins/sockets and quatron oil tube fitting. ROV series 20 flying plug /receptacle with 12 pins/sockets and quatron oil tube fitting. EROV20003BQDBHD12S EROV20B003BQDBHD12P ROV COMPLINTLY MOUNTED CONNECTORS FOR QUTRON OIL TUBE Compliant Mount Compliant Mount RECEPTCLE Hose internal Ø Hose outside Ø Flange Ø Interface Drg No T BROV10004BQDBMC04S T BROV10004BQDBHD07S T BROV20004BQDBHD12S T BROV10B004BQDBMC04P T BROV10B004BQDBHD07P T BROV20B004BQDBHD12P ROV series [10 / 20] flying plug/receptacle with [4 / 7 / 12] pins/sockets and quatron oil tube fitting. ROV series 20 flying plug/receptacle with 12 pins/sockets and quatron oil tube fitting. EROV20004BQDBHD12S EROV20B004BQDBHD12P 19
20 ROV Connectors Compliant Mount Compliant Mount RECEPTCLE Hose internal Ø Hose outside Ø Flange Ø Interface Drg No T BROV10006BQDBMC04S T BROV10006BQDBHD07S T BROV20006BQDBHD12S T BROV10B006BQDBMC04P T BROV10B006BQDBHD07P T BROV20B006BQDBHD12P ROV series [10 / 20] compliantly mounted 90 plug/receptacle with [4 / 7 / 12] pins/sockets and quatron oil tube fitting. ROV series 20 compliantly mounted 90 plug/receptacle with 12 pins/sockets and quatron oil tube fitting. EROV20006BQDBHD12S EROV20B006BQDBHD12P 20
21 ROV Connectors ROV BULKHED MOUNTED CONNECTORS RECEPTCLE Flange Ø Interface Drg No T BROV10H001BQMC04S T BROV10H001BQHD07S T BROV20H001BQHD12S T BROV10G001BQMC04P T BROV10G001BQHD07P T BROV20G001BQHD12P ROV series [10 / 20] bulkhead plug/receptacle with [4 / 7 / 12] pins/sockets. ROV series 20 bulkhead plug/receptacle with 12 pins/sockets. EROV20H001BQHD12S EROV20G001BQHD12P ROV FLYING DUMMY CONNECTORS Please Note: connectors shown RECEPTCLE BROV10L001BQMC04S BROV10L001BQHD07S BROV20L001BQHD12S BROV10M002BQMC04P BROV10M002BQHD07P BROV20M002BQHD12P ROV series [10 / 20] duy plug/receptacle with [4 / 7 / 12] pins/sockets. ROV series 20 duy plug plug/receptacle with 12 pins/sockets. Please specify internal shorting requirements if required for continuity testing. EROV20L001BQHD12S EROV20M002BQHD12P 21
22 ROV Connectors ROV FIXED DUMMY CONNECTORS Please Note: connectors shown RECEPTCLE Flange Ø Interface Drg No & 120 T BROV10L002BQMC04S & 120 T BROV10L002BQHD07S & 120 T BROV20L002BQHD12S & 120 T BROV10M004BQMC04P & 120 T BROV10M004BQHD07P & 120 T BROV20M004BQHD12P EROV20L002BQHD12S EROV20M004BQHD12P ROV COMPLINTLY MOUNTED DUMMY CONNECTORS Compliant Mount Please Note: DigiTRON+ connectors shown Compliant Mount RECEPTCLE Flange Ø Interface Drg No T BROV10L003BQMC04S T BROV10L003BQHD07S T BROV20L003BQHD12S T BROV10M003BQMC04P T BROV10M003BQHD07P T BROV20M003BQHD12P EROV20L003BQHD12S EROV20M003BQHD12P 22
23 ROV Connectors ROV PRKING CONNECTORS RECEPTCLE Flange Ø Interface Drawing 10 not applicable T13234 BROV10L004C 20 not applicable T11161 BROV20L004C 10 not applicable T13234 BROV10M001CD 20 not applicable T11161 BROV20M001CD & e ROV series [10 / 20] parking plug used for very short term parking flying receptacle. & e ROV series 20 parking receptacle used for long term parking flying plug. EROV20L004C EROV20M001CD MNULLY OPERTED PROTECTIVE CPS FOR ROV CONNECTORS Cap for Cap for CP FOR RECEPTCLE CP FOR 10 not applicable BROV10R001C 20 not applicable BROV20R001C 10 not applicable BROV10P001C 20 not applicable BROV20P001C EROV20R001C EROV20P001C Cap for ROV series [10 / 20] plug/receptacle used for marine growth / transport protection. Cap for ROV series 20 plug/receptacle used for marine growth / transport protection. 23
24 ROV Connectors ROV OPERTED PROTECTIVE CPS Cap for Cap for CP FOR RECEPTCLE CP FOR 10 not applicable BROV10R002C 20 not applicable BROV20R002C 10 not applicable BROV10P002C 20 not applicable BROV20P002C Cap for ROV series [10 / 20] receptacle used for very short term subsea protection. Cap for ROV series 20 plug used to protect against marine growth. EROV20R002C EROV20P002C ROV TEST CONNECTORS Please Note: connectors shown RECEPTCLE BROV10T001CDMC04S BROV10T001CDHD07S BROV20T001CDHD12S EROV20T001BQHD12S BROV10T002CMC04P BROV10T002CHD07P BROV20T002CHD12P EROV20T002BQHD12P ROV series [10 / 20] test plug/r eceptacle with [4 / 7 / 12] pins/sockets used for factory testing in air. ROV series 20 test plug/receptacle with 12 pins/sockets used for factory testing in air. Standard wiring convention to SIIS level 3 unless specified by customer. 24
25 Stab Plate Connectors Stab Plate Deployment The stab plates provide movement and clamping force for mate / demate Floating mounts on one connector accoodate misalignment Standard connectors suit popular hydraulic coupler stab plate stack up distances Stab Plate Notes 1 Stab plate connectors are manufactured from 316L stainless steel (UNS S31603), and must be connected to a cathodic protection system (UNS S32550 available). 2 Due to the number different stab plate connector configurations, Siemens Subsea recoend that stab plate connectors are specified and purchased in pairs. For this reason, DigiTRON stab plate connectors are not always compatible with Mini CE. 7 way 90 Stab Plate plug for cable 3 The use duy connectors is advised if the pins on receptacles are likely to be exposed to seawater. The advised maximum cumulative exposure over the life the connector is 28 days, although some pin deterioration may occur in a shorter period. 7 way Stab Plate plug & receptacle for oil tube 4 way Stab Plate receptacle 25
26 Stab Plate Connectors Stab Plate Connectors Page STB PLTE FOR CBLE (001/002) STB PLTE FOR QUTRON OIL TUBE (003/004) 90 STB PLTE FOR CBLE (005/006) RECEPTCLE STB PLTE RECEPTCLE FOR CBLE (B001/B002) STB PLTE RECEPTCLE FOR QUTRON OIL TUBE (B003/B004) 90 STB PLTE RECEPTCLE FOR CBLE (B005/B006) Page Stab Plate Connectors STB PLTE FOR QUTRON OIL TUBE (007/008) 90 STB PLTE RECEPTCLE FOR QUTRON OIL TUBE (B007/B008) 32 Stab Plate Connectors STB PLTE BULKHED MOUNTED (H001) STB PLTE DUMMY (L001/L002) STB PLTE BULKHED MOUNTED RECEPTCLE (G001) STB PLTE DUMMY RECEPTCLE (M001/M002) PROTECTIVE CP FOR STB PLTE (P001) PROTECTIVE CP FOR STB PLTE RECEPTCLE (R001) Stab Plate Connectors 34 STB PLTE TEST (T001) STB PLTE TEST RECEPTCLE (T002) STB PLTE PRKING RECEPTCLE (M006/M007)
27 Stab Plate Connectors Fixed & Floating Mounts One connector in a stab plate pair is normally fitted with floating mounts, the other is fixed. Floating mounts allow approximately ±1 movement laterally. The following tables include a reference to fixed or floating to differentiate the two types mounting. Fixed Flange Floating Flange Split Flanges Split flanges can be provided so that preterminated harnesses can be passed through the hole in the stab plate and then fixed from the other side. Split Flange Large Conductors DigiTRON solder cups can accoodate conductors up to 4 2 (12 awg). Termination to a cable with larger conductors is achieved by using crimps and tailing wires. gland extension piece is used to accoodate this arrangement. Please contact our Customer Support Department for more details. Solid Flange Sleeve Crimp CRIMP DPTOR Large Conductors Gland Extension / Crimps Extension Pieces Crimp daptor 27
28 Stab Plate Connectors Inside Faces Stab Plate Distances DigiTRON Stab Plate connectors are designed to be compatible with coon hydraulic couplers. Flanges on stab plate connectors are 10 thick. If both connectors are mounted on the inside face the plates, the closed distance between the inside the plates must be 100 to / 101 Outside Faces If both connectors are mounted on the outside face the plates, the closed distance between the outside the plates must be 80 to 81. If one connector is mounted on an outside face, and the other on the inside face, the distance between the two faces to which the connectors are fitted must be 90 to / 81 One / Other Faces 90 / 91 28
29 Stab Plate Connectors STB PLTE CONNECTORS FOR CBLE RECEPTCLE Gland Cable Ø Flange Size Flange Interface Drg No G10 8 to x 70 Fixed T BST10001G10MC04S 10 7 G10 8 to x 70 Fixed T BST10001G10HD07S 10 4 G10 8 to x 70 Floating T BST10002G10MC04S 10 7 G10 8 to x 70 Floating T BST10002G10HD07S 10 4 G20 23 to x 70 Fixed T BST10001G20MC04S 10 7 G20 23 to x 70 Fixed T BST10001G20HD07S 10 4 G20 23 to x 70 Floating T BST10002G20MC04S 10 7 G20 23 to x 70 Floating T BST10002G20HD07S G20 23 to x 74 Fixed T BST20001G20HD12S G20 23 to x 74 Floating T BST20002G20HD12S 10 4 G10 8 to x 70 Fixed T BST10B001G10MC04P 10 7 G10 8 to x 70 Fixed T BST10B001G10HD07P 10 4 G10 8 to x 70 Floating T BST10B002G10MC04P 10 7 G10 8 to x 70 Floating T BST10B002G10HD07P 10 4 G20 23 to x 70 Fixed T BST10B001G20MC04P 10 7 G20 23 to x 70 Fixed T BST10B001G20HD07P 10 4 G20 23 to x 70 Floating T BST10B002G20MC04P 10 7 G20 23 to x 70 Floating T BST10B002G20HD07P G20 23 to x 74 Fixed T BST20B001G20HD12P G20 23 to x 74 Floating T BST20B002G20HD12P Stab Plate series [10 / 20] plug/receptacle with [4 / 7 / 12] pins/sockets and size [10 / 20] cable gland. Stab Plate series 20 plug/receptacle with12 pins/sockets and size [10 / 20] cable gland. EST20001G20HD12S EST20002G20HD12S EST20B001G20HD12P EST20B002G20HD12P 29
30 Stab Plate Connectors STB PLTE CONNECTORS FOR QUTRON OIL TUBE RECEPTCLE Hose internal Ø Hose external Ø Flange Size Flange Interface Drg No x 70 Fixed T BST10003DBMC04S x 70 Fixed T BST10003DBHD07S x 70 Floating T BST10004DBMC04S x 70 Floating T BST10004DBHD07S x 74 Fixed T BST20003DBHD12S EST20003DBHD12S x 74 Floating T BST20004DBHD12S EST20004DBHD12S x 70 Fixed T BST10B003DBMC04P x 70 Fixed T BST10B003DBHD07P x 70 Floating T BST10B004DBMC04P x 70 Floating T BST10B004DBHD07P x 74 Fixed T BST20B003DBHD12P EST20B003DBHD12P x 74 Floating T BST20B004DBHD12P EST20B004DBHD12P Stab Plate series [10 / 20] plug/receptacle with [4 / 7 / 12] pins/sockets and quatron oil tube fitting. Stab Plate series 20 plug/receptacle with 12 pins/sockets and quatron oil tube fitting. STB PLTE PRKING RECEPTCLE RECEPTCLE Flange Size Interface Drg No. 10 not applicable x 70 T BST10M not applicable x 70 T BST10M not applicable x 70 T BST20M not applicable x 70 T BST20M007 Stab Plate series [10 / 20] flange mounted parking receptacle. Stab Plate series 20 flange mounted parking receptacle. EST20M006 EST20M007 30
31 Stab Plate Connectors RECEPTCLE Gland Cable Ø Flange Size Flange Interface Drg No G10 8 to x 70 Fixed T BST10005G10MC04S 10 7 G10 8 to x 70 Fixed T BST10005G10HD07S 10 4 G10 8 to x 70 Floating T BST10006G10MC04S 10 7 G10 8 to x 70 Floating T BST10006G10HD07S 10 4 G20 23 to x 70 Fixed T BST10005G20MC04S 10 7 G20 23 to x 70 Fixed T BST10005G20HD07S 10 4 G20 23 to x 70 Floating T BST10006G20MC04S 10 7 G20 23 to x 70 Floating T BST10006G20HD07S G20 23 to x 74 Fixed T BST20005G20HD12S G20 23 to x 74 Floating T BST20006G20HD12S 10 4 G10 8 to x 70 Fixed T BST10B005G10MC04P 10 7 G10 8 to x 70 Fixed T BST10B005G10HD07P 10 4 G10 8 to x 70 Floating T BST10B006G10MC04P 10 7 G10 8 to x 70 Floating T BST10B006G10HD07P 10 4 G20 23 to x 70 Fixed T BST10B005G20MC04P 10 7 G20 23 to x 70 Fixed T BST10B005G20HD07P 10 4 G20 23 to x 70 Floating T BST10B006G20MC04P 10 7 G20 23 to x 70 Floating T BST10B006G20HD07P G20 23 to x 74 Fixed T BST20B005G20HD12P G20 23 to x 74 Floating T BST20B006G20HD12P 90 Stab Plate series [10 / 20] plug/receptacle with [4 / 7 / 12] pins/sockets and size [10 / 20] cable gland. 90 Stab Plate series 20 plug/receptacle with 12 pins/sockets and size [10 / 20] cable gland. EST20005G20HD12S EST20006G20HD12S EST20B005G20HD12P EST20B006G20HD12P 31
32 Stab Plate Connectors RECEPTCLE Hose internal Ø Hose external Ø Flange Size Flange Interface Drg No x 70 Fixed T BST10007DBMC04S x 70 Fixed T BST10007DBHD07S x 70 Floating T BST10008DBMC04S x 70 Floating T BST10008DBHD07S x 74 Fixed T BST20007DBHD12S EST20007DBHD12S x 74 Floating T BST20008DBHD12S EST20008DBHD12S x 70 Fixed T BST10B007DBMC04P x 70 Fixed T BST10B007DBHD07P x 70 Floating T BST10B008DBMC04P x 70 Floating T BST10B008DBHD07P x 74 Fixed T BST20B007DBHD12P EST20B007DBHD12P x 74 Floating T BST20B008DBHD12P EST20B008DBHD12P 90 Stab Plate series [10 / 20] plug/receptacle with [4 / 7 / 12] pins/sockets and quatron oil tube fitting. 90 Stab Plate series 20 plug/receptacle with 12 pins/sockets and quatron oil tube fitting. 32
33 Stab Plate Connectors STB PLTE BULKHED MOUNTED CONNECTORS RECEPTCLE Flange Size Interface Drg No x 70 T BST10H001MC04S x 70 T BST10H001HD07S EST10H001HD07S x 70 T BST20H001HD12S EST20H001HD12S x 70 T BST10G001MC04P x 70 T BST10G001HD07P EST20G001HD07P x 70 T BST20G001HD12P EST20G001HD12P Stab Plate bulkhead mounted series [10 / 20] plug/receptacle with [4 / 7 / 12] pins/sockets. Stab Plate bulkhead mounted series [10 / 20] plug/receptacle with [7 / 12] pins/sockets. STB PLTE DUMMY CONNECTORS Please Note: connectors shown RECEPTCLE Flange Size Flange Interface Drg No x 70 Fixed T BST10L001MC04S x 70 Fixed T BST10L001HD07S x 70 Floating T BST10L002MC04S x 70 Floating T BST10L002HD07S x 74 Fixed T BST20L001HD12S EST20L001HD12S x 74 Floating T BST20L002HD12S EST20L002HD12S x 70 Fixed T BST10M001MC04P x 70 Fixed T BST10M001HD07P x 70 Floating T BST10M002MC04P x 70 Floating T BST10M002HD07P x 74 Fixed T BST20M001HD12P EST20M001HD12P x 74 Floating T BST20M002HD12P EST20M002HD12P Stab Plate series [10 / 20] duy plug/receptacle with [4 / 7 / 12] pins/sockets. Stab Plate series 20 duy plug/receptacle with 12 pins/sockets. Please specify internal shorting requirements if required for continuity testing. 33
34 Stab Plate Connectors PROTECTIVE CPS FOR STB PLTE CONNECTORS Cap for plug Cap for receptacle CP FOR CP FOR RECEPTCLE 10 not applicable BST10P001C 20 not applicable BST20P001C 10 not applicable BST10R001C 20 not applicable BST20R001C Manually operated cap for & e Stab Plate series [10 / 20] plug used for transport / storage / subsea protection. Manually operated cap for & e Stab Plate series 20 receptacle used for transport and storage but NOT subsea protection. EST20P001C EST20R001C STB PLTE TEST CONNECTORS Please Note: connectors shown RECEPTCLE BST10T001CDMC04S BST10T001CDHD07S BST20T001CDHD12S EST20T001HD12S BST10T002CMC04P BST10T002CHD07P BST20T002CHD12P EST20T002HD12P Stab Plate series [10 / 20] test plug/receptacle with [4 / 7 / 12] pins/sockets used for factory testing in air. Stab Plate series 20 test plug/receptacle with 12 pins/sockets used for factory testing in air. 34
35 Diver Connectors Diver Deployment threaded clamp ring ensures secure, lowforce clamping connector pairs without galling Connectors are manufactured from UNS S31603 stainless steel (also available in UNS S32550) for a 30 year design life when deployed in conjunction with a cathodic protection system Diver Notes 1 DigiTRON Diver connectors are not compatible with the Mini CE Range. Mini CE diver connectors were always manufactured with dual keys whereas DigiTRON have a single key. In emergencies, it may be useful to note that a 4 way DigiTRON diver plug will physically fit into a 4 way Mini CE receptacle. Severe damage to both connectors will occur unless care is taken to ensure that the single key on the DigiTRON plug is fitted into the 12 o'clock keyway on the Mini CE receptacle. 4 way Diver plug & receptacle for cable 2 7 and 12 way DigiTRON connectors are NOT Mini CE compatible. 3 Diver connectors are manufactured from UNS S31603 stainless steel and must be connected to a corrosion protection system (e.g. via internal earth ring, earth straps etc.). 4 The use duy connectors is advised if the pins on receptacles are likely to be exposed to seawater for any significant period. The advised maximum cumulative exposure over the life the connector is 28 days, although some pin deterioration may occur in a shorter period. 12 way Diver plug and receptacle for cable Diver bulkhead receptacle 35
36 Diver Connectors Diver Connectors Page DIVER FOR CBLE (001) 90 DIVER FOR CBLE (006) RECEPTCLE DIVER RECEPTCLE FOR CBLE (B001) 90 DIVER RECEPTCLE FOR CBLE (B006) Page Diver Connectors 39 DIVER FLNGE MOUNTED FOR CBLE (002) 90 DIVER FLNGE MOUNTED FOR CBLE (008) DIVER FLNGE MOUNTED RECEPTCLE FOR CBLE (B002) 90 DIVER FLNGE MOUNTED RECEPTCLE FOR CBLE (B008) Diver Connectors DIVER FOR QUTRON OIL TUBE (003) DIVER RECEPTCLE FOR QUTRON OIL TUBE (B003) Diver Connectors DIVER FOR QUTRON OIL TUBE (007) 90 DIVER RECEPTCLE FOR QUTRON OIL TUBE (B007) 40 Diver Connectors 41 DIVER FLNGE MOUNTED FOR QUTRON OIL TUBE (004) DIVER FLNGE MOUNTED RECEPTCLE FOR QUTRON OIL TUBE (B004) 41 36
37 Diver Connectors Page DIVER FLNGE MOUNTED FOR QUTRON OIL TUBE (009) RECEPTCLE 90 DIVER FLNGE MOUNTED RECEPTCLE FOR QUTRON OIL TUBE (B009) Page 41 Diver Connectors DIVER BULKHED MOUNTED (H001) DIVER FLYING DUMMY (L001) DIVER BULKHED MOUNTED RECEPTCLE (G001) DIVER FLYING DUMMY RECEPTCLE (M001) Diver Connectors DIVER FIXED DUMMY (L002) DIVER FIXED DUMMY RECEPTCLE (M002) PROTECTIVE CP FOR DIVER (P001) PROTECTIVE CP FOR DIVER RECEPTCLE (R001) Diver Connectors DIVER TEST (T001) DIVER TEST RECEPTCLE (T002) DIVER PRKING RECEPTCLE (M003) 44 Diver Connectors Diver Connectors 37
38 Diver Connectors DIVER CONNECTORS FOR CBLE RECEPTCLE Gland Cable Ø 10 4 G10 8 to BDIV10001G10MC04S 10 7 G10 8 to BDIV10001G10HD07S 10 4 G20 23 to BDIV10001G20MC04S 10 7 G20 23 to BDIV10001G20HD07S G20 23 to BDIV20001G20HD12S 10 4 G10 8 to BDIV10B001G10MC04P 10 7 G10 8 to BDIV10B001G10HD07P 10 4 G20 23 to BDIV10B001G20MC04P 10 7 G20 23 to BDIV10B001G20HD07P G20 23 to BDIV20B001G20HD12P Diver series [10 / 20] plug/receptacle with [4 / 7 / 12] pins/sockets and size [10 / 20] cable gland. Diver series 20 plug/receptacle with 7 / 12 pins/sockets and size [10 / 20] cable gland. EDIV20001G20HD12S EDIV20B001G20HD12P RECEPTCLE Gland Cable Ø 10 4 G10 8 to BDIV10006G10MC04S 10 7 G10 8 to BDIV10006G10HD07S 10 4 G20 23 to BDIV10006G20MC04S 10 7 G20 23 to BDIV10006G20HD07S G20 23 to BDIV20006G20HD12S 10 4 G10 8 to BDIV10B006G10MC04P 10 7 G10 8 to BDIV10B006G10HD07P 10 4 G20 23 to BDIV10B006G20MC04P 10 7 G20 23 to BDIV10B006G20HD07P G20 23 to BDIV20B006G20HD12P Diver series [10 / 20] 90 plug/receptacle with [4 / 7 / 12] pins/sockets and size [10 / 20] cable gland. Diver series plug/receptacle with 12 pins/sockets and size [10 / 20] cable gland. EDIV20006G20HD12S EDIV20B006G20HD12P 38
39 Diver Connectors DIVER FLNGE DIVER MOUNTED CONNECTORS CONNECTORS FOR CBLE FOR CBLE B B RECEPTCLE RECEPTCLE Gland Cable Gland Gland Cable Cable Ø Flange Interface DigiTRON DigiTRON + + DigiTRON DigiTRON e e Ø Ø Ø B Drg No G10 8 to BDIV10001G10MC04S to BDIV10001G10MC04S G10 G10 8 to to T8399BDIV10001G10HD07S BDIV10002G10MC04S to BDIV10001G10HD07S EDIV10001G10HD07S G10 G20 8 to to T8399BDIV10001G20MC04S BDIV10002G10HD07S to BDIV10001G20MC04S G20 G20 23 to to T8399BDIV10001G20HD07S BDIV10002G20MC04S to BDIV10001G10HD07S EDIV10001G10HD07S G20 G20 23 to to T8399BDIV20001G20HD12S BDIV10002G20HD07S EDIV20001G20HD12S to BDIV20001G20HD12S DIV20001G20HD12S G20 G10 23 to to T15470 BDIV10B001G10MC04P BDIV20002G20HD12S EDIV20002G20HD12S to BDIV10B001G10MC04P G10 G10 8 to to T8399BDIV10B001G10HD07P BDIV10B002G10MC04P to BDIV10B001G10HD07P DIV10B001G10HD07P G10 G20 8 to to T8399BDIV10B001G20MC04P BDIV10B002G10HD07P to BDIV10B001G20MC04P G20 G20 23 to to T8399BDIV10B001G20HD07P BDIV10B002G20MC04P to BDIV10B001G20HD07P EDIV10B001G20HD07P G20 G20 23 to to T8399BDIV20B001G20HD12P BDIV10B002G20HD07P EDIV20B001G20HD12P to ? 3.00 BDIV20B001G20HD12P EDIV20B001G20HD12P 20 DigiTRON 12 + Diver series G20[10 / 23 20] to plug/receptacle with 93 [4 / / 12] pins/sockets T15470 and BDIV20B002G20HD12P size [10 / 20] cable gland. EDIV20B002G20HD12P DigiTRON Diver series [10 20] plug/receptacle with [4 / 7 / 12] pins/sockets and size [10 / 20] cable gland. DigiTRON Diver e Diver series series [10 / 20 20] plug/receptacle flange mounted with plug/receptacle 7 / 12 pins/sockets with [4 and / 7 size / 12] [10 pins/sockets / 20] cable gland. size [10 / 20] cable gland. DigiTRON Diver series [10 20] plug/receptacle with [7 / 12] pins/sockets and size [10 / 20] cable gland. Diver series 20 flange mounted plug/receptacle with 12 pins/sockets and size [10 / 20] cable gland. DIVER FLNGE MOUNTED CONNECTORS FOR CBLE RECEPTCLE RECEPTCLE RECEPTCLE Gland Cable Flange Interface Ø Ø Drg No to T8399 BROV10002BQG10MC04S to T8399 BROV10002BQG10HD07S EROV10002BQG10HD07S Gland Cable to Ø 2.50 T8399 BROV10002BQG20MC04S to T8399 Gland Cable Flange Interface BROV10002BQG20HD07S EROV10002BQG20HD07S Ø23 to Ø 3.00 Drg T15470 No. BROV20002BQG20HD12S EROV20002BQG20HD12S 10 4 G10 8 to BDIV10006G10MC04S to T8399 BROV10B002BQG10MC04P 10 7 G10 8 to to T8399 BDIV10006G10HD07S BROV10B002BQG10HD07P EROV10B002BQG10HD07P G10 8 G20 to to T8399BDIV10006G20MC04S BDIV10008G10MC04S to T8399 BROV10B002BQG20MC04P G10 8 G20 to to T8399BDIV10006G20HD07S BDIV10008G10HD07S to T8399 BROV10B002BQG20HD07P EROV10B002BQG20HD07P G20 23 G20 to to T8399BDIV20006G20HD12S BDIV10008G20MC04S EDIV20006G20HD12S to T15470 BROV20B002BQG20HD12P EROV20B002BQG20HD12P G20 23 G10 to to T8399 BDIV10B006G10MC04P BDIV10008G20HD07S Diver series [10 / 20] flange mounted plug/receptacle with [4 / 7 / 12] pins/sockets and size [10 / 20] cable gland Diver 7 G20 23 series [10 / G10 to 35 20] flange mounted to plug/receptacle with 2.25 T15470 [7 / 12] pins/sockets BDIV10B006G10HD07P BDIV20008G20HD12S EDIV20008G20HD12S and size [10 / 20] cable gland G10 8 G20 to to T8399BDIV10B006G20MC04P BDIV10B008G10MC04P G10 8 G20 to to T8399BDIV10B006G20HD07P BDIV10B008G10HD07P G20 23 G20 to to T8399BDIV20B006G20HD12P BDIV10B008G20MC04P EDIV20B006G20HD12P 10 DigiTRON 7+ Diver G20 series [10 23 to / 20] plug/receptacle with [43.00 / 7 / 12] pins/sockets T8399 and BDIV10B008G20HD07P size [10 / 20] cable gland. 20 DigiTRON 12e Diver G20 series to 90 35plug/receptacle 187 with 9312 pins/sockets 3.20 T15470 and size [10 / BDIV20B008G20HD12P 20] cable gland. EDIV20B008G20HD12P Diver series [10 / 20] 90 flange mounted plug/receptacle with [4 / 7 / 12] pins/sockets and size [10 / 20] cable gland. Diver series flange mounted plug/receptacle with 12 pins/sockets and size [10 / 20] cable gland. 39
40 Diver Connectors DIVER CONNECTORS FOR QUTRON OIL TUBE RECEPTCLE Hose internal Ø Hose outside Ø Hose Code DB BDIV10003DBMC04S DB BDIV10003DBHD07S DB BDIV20003DBHD12S DB BDIV10B003DBMC04P DB BDIV10B003DBHD07P DB BDIV20B003DBHD12P Diver series [10 / 20] plug/receptacle with [4 / 7 / 12] pins/sockets and quatron oil tube fitting. Diver series20 plug /receptacle with 12 pins/sockets and quatron oil tube fitting. EDIV20003DBHD12S EDIV20B003DBHD12P RECEPTCLE Hose internal Ø Hose outside Ø BDIV10007DBMC04S BDIV10007DBHD07S BDIV10007DBHD12S BDIV10B007DBMC04P BDIV10B007DBHD07P BDIV20B007DBHD12P Diver series [10 / 20] 90 flange mounted plug/receptacle with [4 / 7 / 12] pins/sockets and quatron oil tube fitting. Diver series flange mounted plug/receptacle with 12 pins/sockets and quatron oil tube fitting. EDIV20007DBHD12S EDIV20B007BQHD12P 40
41 Diver Connectors DIVER FLNGE MOUNTED CONNECTORS FOR QUTRON OIL TUBE RECEPTCLE Hose internal Ø Hose outside Ø Flange Ø Interface Drg No T BDIV10004DBMC04S T BDIV10004DBHD07S T BDIV20004DBHD12S T BDIV10B004DBMC04P T BDIV10B004DBHD07P T BDIV20B004DBHD12P Diver series [10 / 20] flange mounted plug/receptacle with [4 / 7 / 12] pins/sockets and quatron oil tube fitting. Diver series 20 flange mounted plug/receptacle with 12 pins/sockets and quatron oil tube fitting. EDIV20004DBHD12S EDIV20B004DBHD12P RECEPTCLE Hose internal Ø Hose external Ø Flange Ø Interface Drg No T8399 BDIV10009G10MC04S T8399 BDIV10009G10HD07S T15470 BDIV20009G20HD12S T8399 BDIV10B009G10MC04P T8399 BDIV10B009G10HD07P T15470 BDIV20B009G20HD12P Diver series [10 / 20] 90 flange mounted plug/receptacle with [4 / 7 / 12] pins/sockets and quatron oil tube fitting. Diver series flange mounted plug/receptacle with 12 pins/sockets and quatron oil tube fitting. EDIV20009G20HD12S EDIV20B009G20HD12P 41
42 Diver Connectors DIVER BULKHED MOUNTED CONNECTORS RECEPTCLE Flange Ø Interface Drg No T BDIV10H001MC04S T BDIV10H001HD07S T BDIV20H001HD12S EDIV20H001HD12S T BDIV10G001MC04P T BDIV10G001HD07P T BDIV20G001HD12P EDIV20G001HD12P Diver series [10 / 20] bulkhead mounted plug/receptacle with [4 / 7 / 12] pins/sockets. Diver series 20 bulkhead mounted plug/receptacle with 12 pins/ sockets. DIVER FLYING DUMMY CONNECTORS Please Note: connectors shown RECEPTCLE BDIV10L001MC04S BDIV10L001HD07S BDIV20L001HD12S EDIV20L001HD12S BDIV10M001MC04P BDIV10M001HD07P BDIV20M001HD12P EDIV20M001HD12P Diver series [10 / 20] duy plug/receptacle with [4 / 7 / 12] pins/sockets. Diver series 20 duy plug/receptacle with 12 pins/sockets. Please specify internal shorting requirements if required for continuity testing. 42
43 Diver Connectors DIVER FIXED DUMMY CONNECTORS Please Note: connectors shown RECEPTCLE Flange Ø Interface Drg No T BDIV10L002MC04S T BDIV10L002HD07S T BDIV20L002HD12S EDIV20L002HD12S T BDIV10M002MC04P T BDIV10M002HD07P T BDIV20M002HD12P EDIV20M002HD12P Diver series [10 / 20] flange mounted duy plug/receptacle with [4 / 7 / 12] pins/sockets. Diver series 20 flange mounted duy plug plug/receptacle with 12 pins/sockets. Please specify internal shorting requirements if required for continuity testing. PROTECTIVE CPS FOR DIVER CONNECTORS Cap for Cap for Cap for Cap for RECEPTCLE 10 not applicable BDIV10P001C 20 not applicable BDIV20P001C EDIV20P001C 10 not applicable BDIV10R001C 20 not applicable BDIV20R001C EDIV20R001C Protective cap for & e Diver series [10 / 20] plug. Protective cap for & e Diver series 20 receptacle. 43
44 Diver Connectors DIVER TEST CONNECTORS Please Note: connectors shown RECEPTCLE BDIV10T001CDMC04S BDIV10T001CDHD07S BDIV20T001CDHD12S EDIV20T001HD12S BDIV10T002CMC04P BDIV10T002CHD07P BDIV20T002CHD12P EDIV20T002HD12P Diver series [10 / 20] Test plug/receptacle with [4 / 7 / 12] pins/sockets and size [10 / 20] cable gland. Diver series 20 Test plug/receptacle with 12 pins/sockets and size 20 cable gland. DIVER PRKING RECEPTCLE RECEPTCLE Flange Ø Interface Drg No. 10 not applicable T BDIV10M not applicable T BDIV20M003 EDIV20M003 & e Diver series [10 / 20] flange mounted receptacle. 44
45 Subsea Cable Siemens Subsea are pleased to fer complete harnesses made up from connectors and subsea cable. Our standard screened cables are always available from stock and specifically designed for extended life subsea. Other cable specifications are available on request. 4 way cable Part 75004TR Sheath Drain Wire Outside diameter Sheath material 18.2 Polyurethane Screen Minimum static bend radius 182 Minimum dynamic bend radius 273 in air 371 /km in water 105 /km Conductor Voltage rating 600V ac/1000v dc Resistance Conductor size 13.3 /km Braid Bedding Sheath Depth rating 3000 metres 7 way cable Part 75007TR Sheath Braid Outside diameter 18.2 Sheath material Minimum static bend radius Polyurethane 200 Screen Minimum dynamic bend radius 300 in air 399 /km in water Voltage rating 132 /km 600V ac/1000v dc Conductor Resistance Conductor size 13.3 /km Drain Wire Bedding Sheath Depth rating 3000 metres Part 12 way cable 75012TR Sheath Braid Outside diameter Sheath material 22.3 Polyurethane Screen Minimum static bend radius 300 Minimum dynamic bend radius 400 in air 565 /km in water Voltage rating 164 /km 600V ac/1000v dc Conductor Resistance Conductor size 13.3 /km Drain Wire Bedding Sheath Depth rating 3000 metres 45
46 DigiTRON Junction Boxes 3000 metres depth rating Junction Boxes for cable lthough not as simple as oil tube junction boxes, cable junction boxes are available in a wide range configurations. Cable junction boxes are usually gel filled and pressure compensated. For permanent fixtures, cables enter through penetrators fitted with pressure compensated cable glands. Disconnectable Junction Boxes Disconnectable junction boxes can be provided through standard DigiTRON bulkhead connectors fitted to a gel filled pressurecompensated acetal chamber. Connection is made via inline DigiTRON connectors terminated to cable or quatron oil tube. Please contact our Customer Support Department for specific Junction Box requirements. ROV Retrievable Electrical Distribution Units Connector Manifold Siemens Subsea can now fer various ROV Retrievable Electrical Distribution Units (REDU s). These can be base plate mounted on client structure and are available in a range connector configurations. The units have cathodic protection through the mating connectors on the Electrical Distribution Unit and base plate. Disconnectable Junction Boxes (horizontally mounted only) typical example an ROV Retrievable Electrical Distribution Unit (REDU) (horizontally mounted only) 46
47 and ROV REDU (Retrievable Electrical Distribution Unit) 4000 metres depth rating This is the evolution from our current standard REDU (see previous page). This does not replace the existing REDU but fers 4000 metres operation with a higher specification up to 11 connections. The units have full cathodic protection through the input connector on the base plate which can be configured as the CP connection only Improved compensated design rated to 4000 metres Coon input connector Coon guide posts Standard base plate for all variants Please contact our Customer Support Department for specific REDU requirements. REDU ing System: REDU DB Part Connector BCDEF REDU 004G2002 REDU 004DB03 REDU 004DB04 REDU 004DB05 REDU 004DB06 Connector configuration for REDU 6 way. Ghosted connectors C,D,E & F are the additional connector options available PRODUCT FMILY REDU: Retrievable Electrical Distribution Unit TYPE OF REDU represents the different configurations Tronic Technical Department to advise on placement order MTERIL Indicates the type material: : Stainless Steel (UNS S31603) standard BSE PLTE CONNECTOR TYPE This connector is always a 12 way stab plate connector. Make selection from table, bottom left page. 004DB: Straight quatron 50 oil tube termination NUMBER OF CONNECTOR OUTPUTS 08: 8f connector outputs Base Plate Connector 002G10: Straight G10 cable termination 002G20: Straight G20 cable termination 004DB: Straight quatron 50 oil tube termination 004DC: Straight quatron 75 oil tube termination 006G10: Right angled G10 cable termination 006G20: Right angled G20 cable termination 008DB: Right angled quatron 50 oil tube termination 008DC: Right angled quatron 75 oil tube termination L002*: Duy / CP connector * If L002 connector is used the input connector is to be included in the number outputs. Part REDU 004DB07 REDU 004DB08 REDU 004DB09 REDU 004DB10 REDU 004DB11 Connector configuration for REDU 11 way. Ghosted connectors G, H, J & K are the additional connector options available. Connector BCDEFGH I JK 47
48 quatron Oil Tube 4000 metres depth rating Oil tube jumpers and harnesses are an alternative to cable. They are formed by pulling conductors through the quatron hose, cutting to length, terminating the conductors to the solder cups, fixing the oil tube to the connector backshells, leak testing and filling with oil. quatron is more flexible than cable and is ten more convenient for short jumpers and / or complex harnesses consisting several oil tube segments, connectors, sensors, actuators and marshalling or junction boxes. Complex harnesses and jumpers can be procured on a single purchase order, factory assembled in ideal conditions and delivered with full warranty. quatron hose is available in two sizes; 12.7 (0.5 ) and 19 (0.75 ) diameter bore. PVC / Nitrile cover Polyester yarn braid ramid fibre longitudinal strain member Styrene Butadiene (SBR) inner tube quatron 50 & 75 oil tube size comparison 48
49 and quatron Junction Boxes 4000 metres depth rating Junction Boxes for quatron Oil Tube major advantage quatron oil tube is the ease with which complex harnesses can be factory assembled. Harnesses can include connectors, actuators, sensors and junction boxes. The junction box usually serves one two purposes: 1 Distribution One input signal is distributed to several outputs. n insert facilitates insulation around the conductor junctions. 2 Marshalling One input connector has it s conductors marshalled to several output connectors. In this configuration, no inserts are required. Part JB01DB02DBC JB01DB03DBC JB01DB04DBC JB02DB03DBC JB02DB04DBC JB03DB04DBC JB04DB04DBC JB01DC02DBC JB01DC03DBC JB01DC04DBC JB02DC03DBC JB02DC04DBC JB01DC02DCC JB02DC02DCC Description 3 ports (1 to 2), to suit 12.7 (0.5 ) hose 4 ports (1 to 3), to suit 12.7 (0.5 ) hose 5 ports (1 to 4), to suit 12.7 (0.5 ) hose 5 ports (2 to 3), to suit 12.7 (0.5 ) hose 6 ports (2 to 4), to suit 12.7 (0.5 ) hose 7 ports (3 to 4), to suit 12.7 (0.5 ) hose 8 ports (4 to 4), to suit 12.7 (0.5 ) hose 1 x 19 (0,75 ) hose to 2 x 12.7 (0.5 ) hose 1 x 19 (0,75 ) hose to 3 x 12.7 (0.5 ) hose 1 x 19 (0,75 ) hose to 4 x 12.7 (0.5 ) hose 2 x 19 (0,75 ) hose to 3 x 12.7 (0.5 ) hose 2 x 19 (0,75 ) hose to 4 x 12.7 (0.5 ) hose 1 x 19 (0,75 ) hose to 2 x 19 (0.75 ) hose 2 x 19 (0,75 ) hose to 2 x 19 (0.75 ) hose Please Note: Other options available. Junction Box Harness ssembly (1 x quatron 75 to 3 x quatron 50) Junction Box Harness ssembly (1 x quatron 75 to 2 x quatron 75) 49
50 and quatron Isolated Chamber Junction Boxes 4000 metres depth rating ICJB (Isolated Chamber Junction Box) This is the evolution from our current standard quatron Junction Box. This new product does not replace the existing design but fers an alternative solution giving customers a higher specification design which is pressure compensated, isolated and will work to a depth 4000 metres. Currently available in Stainless Steel (UNS S31603) as standard (cathodic protection required). Compensated design Rated to 4000 metres Each leg has a penetrator separating the hoses from the internals the box JIC 3 /4 and 1 1 /16 interface fittings now available Standard DigiTRON connector block parts used internally Can operate in any orientation Hose Interface Fittings We can now fer JIC and the standard Omnitec / quatron hose fittings in two sizes. Below is a typical table for the number variations available from 1 in and 1 out, to 4 in and 4 out for JIC fitting for 0.5 NB quatron hose. This option allows a customer to specify any the hose fittings in a combination to suit their requirements. Please contact our Customer Support Department for part numbers and specific Junction Box requirements. Part ICJB01F01F ICJB01F02F ICJB01F03F ICJB01F04F ICJB02F02F ICJB02F03F ICJB02F04F ICJB03F03F ICJB03F04F ICJB04F04F Description 2 ports (1 to 1), to suit 12.7 (0.5 ) hose 3 ports (1 to 2), to suit 12.7 (0.5 ) hose 4 ports (1 to 3), to suit 12.7 (0.5 ) hose 5 ports (1 to 4), to suit 12.7 (0.5 ) hose 4 ports (2 to 2), to suit 12.7 (0.5 ) hose 5 ports (2 to 3), to suit 12.7 (0.5 ) hose 6 ports (2 to 4), to suit 12.7 (0.5 ) hose 6 ports (3 to 3), to suit 12.7 (0.5 ) hose 7 ports (3 to 4), to suit 12.7 (0.5 ) hose 8 ports (4 to 4), to suit 12.7 (0.5 ) hose DB quatron (0.5" NB) Oil Tube (Omnitec M25 fitting) DC quatron (0.75" NB) Oil Tube (Omnitec M32 fitting) F quatron (0.5" NB) Oil Tube ( " 16 JIC fitting) H quatron (0.75" NB) Oil Tube (1 " 12 JIC fitting) 50
51 and Harness ssemblies Integrated Scope Supply Siemens Subsea can supply high quality, high reliability packages with a single warranty. These can range from single legged harnesses to multilegged harness assemblies utilising pressure and temperature transducers designed to suit our clients requirements. The harnesses in an integrated scope supply will consist and Connectors, quatron Hose and sensors. Our hose facility has been purpose built for assembling oil filled harnesses in controlled conditions. The length the internal clean working area is ideal for the longest harness assemblies. The working environment is fully climate controlled (temperature and humidity) with a full clean air filtration system. The pictures shown on this page show typical examples harness assemblies supplied as integrated packages / scopes. Please contact our Customer Support Department for specific harness requirements. 51
52 and Interface Drawings SECTION Interface Drawing No: T f HOLES M6 x 1.06H 15 Ø TYP SECTION BB Interface Drawing No: T8399 B TYP 4f THRO' HOLES M6 x 1.06H Ø 0.13 Ø Ø Ø Ø Ø TYP Ø ± TYP MIN 0.8 SURFCE FINISH TO BE MINTINED OVER Ø MIN MX B Ø SECTION CC Interface Drawing No: T Ø Ø Ø Ø f HOLES M6 x 1.06H TYP Ø 0.13 C TYP f Ø6 DOWEL Ø f Ø6 DOWEL Ø f HOLES M6 x 1.06H Ø 0.13 Ø65.00 ± TYP TYP TYP Ø SECTION DD Interface Drawing No: T Ø Ø Ø Ø f HOLES M6 x 1.06H Ø 0.13 D f Ø6 DOWEL Ø 0.13 (OPTIONL) TYP D C MIN 0.8 SURFCE FINISH TO BE MINTINED OVER Ø TYP MIN TYP 0.8 SURFCE FINISH TO BE MINTINED OVER Ø95 Interface Drawing No: T11127 Interface Drawing No: T11161 SECTION EE E SECTION FF F F E MIN TYP 4f HOLES M6 x 1.06H Ø MIN TYP DRWINGS FOR INFORMTION ONLY ll dimensions in millimetres 52
53 and Interface Drawings 53
54 and Coon Modular Diagram TEE PIECE EXTENSION DIVER BODY BULKHED FLNGE RIGHT NGLE EXTENSION Diver DIVER RECEPTCLE BODY SPCER FLNGE (For ) FLNGE (For ) DUMMY BCKSHELL QUTRON BCKSHELL Protective Caps STB PLTE BULKHED FIXED FLNGE Stab Plate Protective Caps STB PLTE BODY STB PLTE RECEPTCLE BODY STB PLTE BULKHED RECEPTCLE FLOTING FLNGE SPLIT FLNGE FIXED SPLIT FLNGE FLOTING COMPLINT FLNGE FOR GLNDED BCKSHELL 3 /4 JIC BCKSHELL ROV BULKHED 1 1 /16 JIC BCKSHELL FRONT RING ROV BODY COMPLINT FLNGE FOR RECEPTCLE STOP END FITTING QUTRON HOSE ROV Protective Caps ROV RECEPTCLE BODY ROV BULKHED RECEPTCLE SPCER DUMMY/ PRKING FLNGE PROTECTIVE CP FOR STOP END FITTING GLNDED BCK SHELL PROTECTIVE CP FOR RECEPTCLE 54
55 and Examples QUTRON HOSE FITTING G10 CBLE GLND ROV CONNECTOR WITH DUL QUTRON HOSE EXITS G20 CBLE GLND DUMMY BCKSHELL DIVER MTE CONNECTOR WITH EXTENDED G20 CBLE GLND FLNGED DUMMY BCKSHELL JIC HOSE FITTING OMNITEC HOSE FITTING 1IN, 3OUT QUTRON HOSE SPLITTER FISH TIL HNDLE G10 TO G10 CBLE SPLICE TBR HNDLE STB PLTE RECEPTCLE CONNECTOR WITH 90 QUTRON HOSE FITTING PDDLE HNDLE ROV RECEPTCLE CONNECTOR WITH COMPLINT FLNGE & G10 CBLE GLND XYZ HNDLE 55
56 and Junction Boxes, Penetrators & Splices Size 10 Connector Front End RIGHT NGLE EXTENSION Size 20 Connector Front End DPTOR JUNCTION BOX FITTING QUTRON HOSE QUTRON HOSE FITTING HLF ENDED G10 CBLE GLND (No diaphragm) G10 CBLE GLND BULKHED FLNGE JUNCTION BOX FITTING GLNDED BCK SHELL G20 CBLE GLND FOR SIZE 10 CONNECTORS QUTRON HOSE FITTING PENETRTOR BLOCK JIC HOSE FITTING OMNITEC HOSE FITTING G10 CBLE GLND STOP END JUNCTION BOX FITTING QUTRON HOSE G10 CBLE SPLICE G20 CBLE SPLICE G20 CBLE GLND FOR SIZE 10 CONNECTORS JIC HOSE FITTING STOP END JUNCTION BOX FITTING GLNDED BCK SHELL OMNITEC HOSE FITTING 56
57 Glossary Terms Term quatron... Bulkhead... Description The oil tube system used as an alternative to cable. boundary wall separating fluids on either side. There may be a pressure difference between the two sides. Bulkhead mounted connector... Cable to conductor boot... Cathodic protection... CE / Controlled Environment... Connector... Half a connector pair. Duy connector... connector that fits into, and seals against, a bulkhead. The mating end the connector points to the external side, while the internal side is fitted with tails to facilitate termination within the enclosure. Note that a bulkhead connector is similar to a penetrator except that a connector is easily demated. n elastomeric component that seals over the cable sheath and the individual conductors. Usually located within a cable gland where the individual conductors emerge from the cable. n electrochemical method controlling corrosion, achieved by making a metal cathodic by means impressed current or attachment to a sacrificial anode (usually magnesium, aluminium or zinc). patented fluid filled Siemens Subsea connector principle. The electrical sockets contained within the plug are protected within oil chambers (the 'Controlled Environment'). During mating, the receptacle pins enter the controlled environment through seals, before the electrical connection is made in the controlled environment. Connector having a fully operating mating front end but a blank backshell at the termination end. Duies have two main uses: 1) Protecting contacts that might otherwise be exposed to seawater. 2) Creating a loop between a pair conductors for test purposes e.g. when pulling through an umbilical. Field assembled gland... cable gland that can be assembled on site / fshore. Flange mounted... connector with a flange. Note: This is not the same as a bulkhead mounted connector. Gel... self repairing, hydrophobic gel used by Siemens Subsea to fill subsea glands. The gel allows pressure balancing and is electrically inert. Gland... The part the connector / penetrator where a cable is terminated. Inline connector... Connectors that terminate to a cable or oil tube segment. Insert... The centre part the connector / penetrator containing the electrical contacts. Instrumentation... Typically the range catered for by the DigiTRON connector e.g: up to 1000V and 40. Junction box... component used in subsea systems where several cables / conductors are joined together. junction box contains an insert which performs a multiple conductor joint whilst maintaining conductor sheath integrity. Marshalling box... component used in oil tube systems to collect the inputs from several 4 way connectors to a 7 or 12 way connector. Unlike a junction box, signals are not duplicated. Oil tube... n alternative to cable for subsea jumpers. The conductors are contained within a pressurebalanced oilfilled hose rather than within a cable. Parking receptacle... Parking receptacles are very simple devices that allow a loose CE plug connector to be 'parked' or fixed. CE plug connectors do not need duy connectors as the sockets are protected from seawater by the oil chambers. PEEK (Victrex Limited)... PolyEtherEtherKetone. n engineering thermoplastic with excellent insulation properties. Penetrator... permanent connection through a bulkhead.... The connector half which fits inside the receptacle. In CE terminology, the plug contains electrical sockets within oilfilled chambers.... The connector half into which the plug is inserted. In CE terminology, the receptacle contains the electrical pins. Redundancy... chieved by supplying a back up to key system components so that failure one component will not result in electrical failure. ROV... Subsea Remotely Operated Vehicle. Used to carry out tasks that are beyond economic diver depth, range or capability. Shuttle pin... The pin that seals the oil chambers within CE plug connectors when unmated. The shuttle pin is displaced by the receptacle pin during mating. Stab plates... Two plates which contain hydraulic and/or electrical connectors. Enables remote mating the connectors when the distance between the plates is reduced. Termination sleeve... sleeve that fits over terminations, providing a continuous insulation path. Test connectors... Low cost connectors, specifically manufactured for system testing. They are not waterpro and are usually fitted with long tails for connecting to test equipment. If a system terminates in a true subsea receptacle, a test plug is used to prevent damage to the pins. UNS S The standard grade stainless steel used for most subsea connectors when a corrosion protection system is in operation. UNS S superior specification stainless steel (super duplex) used to achieve long life where protection systems are not available/reliable. 57
58 ftermarket Services Siemens Subsea are recognised throughout the global subsea oil and gas industry as leading in the design, manufacture and installation reliable subsea electrical and optical connection systems. Our ftermarket Services Group provides a range postsales support to the industry. We have a dedicated Field Service team 22 qualified and fullytrained UK installation engineers along with teams based in Brazil, US and Malaysia, whose expertise is utilised around the world, supporting our customers at both onshore and fshore locations. Our ftermarket Services Connector installation and test Offshore deployment support Spares and inventory management Investigation support Condition reports / inspections Umbilical test Test connector hire Capabilities Termination, installation and test the complete connector range 24 hour access to inventory for spares and emergency scenarios Priority Service Response mobilisation within hours Fully equipped vehicles and installation containers for large on site project requirements Onsite system interrogation and applications advice 24 hour 7 days a week telephone emergency response service Paperless documentation system available to complement hard copy project records Installations assured by warranty Global Capabilities Our UK based service team has extensive experience installing the full range connectors at onshore and fshore locations around the world. dditionally, we provide growing and dedicated incountry support utilising locally based personnel. This not only provides focused incountry resource but also fers indigenous workforces where local content is required. In country support is available in the UK, Europe, US, Brazil, West frica and Malaysia. Service Team Prile Over 20 years experience in the provision onshore and fshore support on a global basis. Today, our installation engineers boast a combined experience over 100 manyears and we continue to grow in order to meet market demand. Only our Engineers are certified for the installation and test the Siemens Subsea connector range, ensuring the highest possible electrical performance throughout the connector life time. 58
59 February 2013
Subsea Instrumentation Systems
Subsea Instrumentation Systems subsurface systems TM The DigiTRON range subsea instrumentation connectors combines the many field proven features the Mini CE connector with the latest in design technology.
More informationSiemens Subsea Connectors Data Sheets (Feb 2014)
Siemens Subsea Connectors Data Sheets (Feb 2014) Contents 1. DigiTRON+ and e Connectors...2 1.1 ROV Connectors...3 1.2 Stab Plate Connectors...4 1.3 Diver Connectors...5 1.4 Subsea Cable...6 1.5 Junction
More informationHandling instructions for GISMA connectors HI
Content 1. GENERAL... 3 2. SCOPE... 3 3. PROTECTION, HANDLING AND SHIPMENT... 3 4. UNPACKING... 4 5. STORAGE... 4 5.1. Short Term Connector Storage... 4 5.2. Long Term Connector Storage... 4 6. Jumper
More informationConnector Operations Manual
Document No: 0071 Connector Operations Manual For Siemens Subsea Connectors & Sensors - Protection, Storage, Shipment, Unpacking, Deployment & Maintenance Instructions www.siemens.com/energy/connector-operations-manual
More informationDigiTRON Single Connectors Installation, Operations and Maintenance Manual
Document No: IOM-002 DigiTRON Single Connectors Installation, Operations and Maintenance Manual Protection, Storage, Shipment, Unpacking, Deployment & Maintenance Instructions www.siemens.com/energy/connector-operations-manual
More informationHandling instructions for GISMA connectors HI
Content 1. GENERAL... 3 2. SCOPE... 3 3. PROTECTION, HANDLING AND SHIPMENT... 3 4. UNPACKING... 4 5. STORAGE... 4 5.1. Short Term Connector Storage... 4 5.2. Long Term Connector Storage... 4 6. Jumper
More informationAPPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL
APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL ROV & AUV PRODUCTS GRE (Glass Reinforced Epoxy) CS-MS 55 & 66 SERIES MINI-CON HUMMER GLOBE-CON ALL-WET
More informationSpecTRON 10 Connector Operations Manual
Document No: 0074 SpecTRON 10 Connector Operations Manual Protection, Storage, Shipment, Unpacking, Deployment & Maintenance Instructions www.siemens.com/energy/connector-operations-manual Page 1 SpecTRON
More informationTeledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)
PER CO # 33537 Approved By: M. Bartell Originator: Checked By: S. Jackson B. Cornelius 1 of 8 ODN-084-23 23 TITLE: Installation and Operation Manual for Dry- Teledyne Oil & Gas 1026 North Williamson Blvd.
More information32374 R. Jazowski 4/4/ D. W. Mudge G. Sivik 1 of 8 ODN TITLE: Installation & Operation Manual for Nautilus G2 Connectors
PER CO # Approved By: 32374 R. Jazowski Originator: Checked By: W. Mudge G. Sivik 1 of 8 ODN-342-23 23 TITLE: Installation & Operation Manual for Nautilus Teledyne Oil & Gas 1026 North Williamson Blvd.
More informationS. Jackson B. Cornelius 1 of 16 ODN TITLE: Installation and Operation Manual for Nautilus Connectors. Teledyne Oil & Gas
PER CO # 38393 Approved By: T. Sidenstricker Originator: Checked By: S. Jackson B. Cornelius 1 of 16 ODN-004-23 23 TITLE: Installation and Operation Manual for Teledyne Oil & Gas 1026 North Williamson
More informationMay08 Rev B
Qualification Test Report 0.64 mm Generation Y Terminal 501-657 20May08 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on the Tyco Electronics 0.64 mm Generation Y Terminal to determine its conformance
More informationPlok. Rapid Mating Multi-Pin Industrial Connector. Amphenol Industrial Sine Systems * Pyle Connectors Corporation
- Plok Rapid Mating Multi-Pin Industrial onnector mphenol Industrial Sine Systems * Pyle onnectors orporation eatures and enefits Rapid mate spring loaded, push to mate, pull to unmate coupling system
More informationDigiTRON Electrical Flying Leads, Jumpers and Harness Assemblies Site Received Test Manual
1 Document No: SRT-001 DigiTRON Electrical Flying Leads, Jumpers and Harness Assemblies Site Received Test Manual www.siemens.com/energy/connector-operations-manual 2 This page records the revision status
More informationGENERAL APPLICATION NOTES
GENERAL APPLICATION NOTES There are common considerations when using our connectors. Additional considerations may apply based on the particular connector being used, the application, and conditions in
More informationSpecTRON 5 PROTECTION, STORAGE, SHIPMENT, UNPACKING, DEPLOYMENT & MAINTENANCE INSTRUCTIONS
Page 1 SpecTRON 5 PROTECTION, STORAGE, SHIPMENT, UNPACKING, DEPLOYMENT & MAINTENANCE INSTRUCTIONS General Thank you for purchasing a Siemens Subsea SpecTRON 5 product. The information that follows is an
More informationSummary of Architecture Parallel Session. G. Hallewell/CPP Marseille P. Piattelli/ LNS Catania
Summary of Architecture Parallel Session G. Hallewell/CPP Marseille P. Piattelli/ LNS Catania Parallel Session A1.2: Architecture: First session mainly devoted to undersea connectivity Chair: G. HALLEWELL,
More informationBENNEX Advanced Cable Termination ACT Subsea Electrical Termination
Doc ID 101008 rev 1 BENNEX Advanced Cable Termination ACT Subsea Electrical Termination Key Business Areas Seismic ROV Distribution & Monitoring Umbilical Terminations Process Monitoring Valves Design
More informationwww.siemens.com/energy/connector-operations-manual Created C.Plant General Thank you for purchasing a Siemens Subsea Connectors SpecTRON 10 Mk II product. The information that follows is an overview of
More informationFigure 1: Hydrostatic Pressure Forces Are Perpendicular to the Surface
Pressure Hulls and Canisters 2 Cornerstone Electronics Technology and Robotics III (Notes primarily from Underwater Robotics Science Design and Fabrication, an excellent book for the design, fabrication,
More informationHydro Bond Engineering Ltd Electrical Penetrators: Manned and Unmanned Systems HPS (Hydro Bond Penetrator Series)
Hydro Bond Engineering Ltd Electrical Penetrators: sales@hydrogroup.uk www.hydrogroupcom tel: +44 (0)1224 822996 fax: +44 (0)1224 825142. sales@hydrogroup.uk www.hydrogroup-asia.com tel: +65 63343566 fax:
More informationellison sensors international
PR3900 HAZARDOUS AREA PRESSURE TRANSMITTER ATEX CERTIFIED AND ALL EQUIVALENTS FOR HAZARDOUS AREAS: ZONE 0 GAS GROUP IIC, TEMPERATURE CLASS T4 AND ZONE 20 DUST PROTECTION BY INTRINSIC SAFETY TO EEXIA IIC
More informationL3 Pressure and Level transmitter
SENSORS FOR AND BIOPHARMA. Product Information L3 L3 Pressure and Level transmitter Range of applications Hydrostatic Level measurement in dynamic temperature environments Pressure measurement in pipes
More informationIECEx Certificate of Conformity Annexe
for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment
More informationvalves and actuators SUBSEA ACTUATION
valves and actuators SUBSEA ACTUATION 100 C 55 M 20 Y 0 K 0 C 0 M 0 Y 80 K subsea PetrolValves offers a complete single-source integrated solution for manual or actuated high integrity ball, check, slab
More informationOuter contact 1.0 milliohm max.
MCX.4 11/27/01 5:17 PM Page 17 Connex MCX Series connectors are ideal for applications and designs where weight and space savings are critical. This series has a 50 ohm impedance structure which operates
More informationMODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT
MODEL 862-000-200 ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT DOCUMENT NO. 430-007H September 20, 2005 S/N IMAGENEX TECHNOLOGY CORP. 209-1875 BROADWAY
More information38999 Space grade ESA/SCC Section. MIL-DTL Space Grade Circular Connectors
38999 Space grade ESA/SCC 3401 Section II MI-DT 38999 Space Grade Circular Connectors 59 38999 Space Grade ESA/SCC 3401 Contents 38999 Space Grade ESA/SCC 3401 SCC Specification.......................................................61
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk WIRE ROPE CUTTER RCO40LP PRODUCT CODE No. 980503 INSTRUCTIONS FOR
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HOSE/UMBILICAL CUTTER HCV100 PRODUCT CODE No. 980292 INSTRUCTIONS
More informationSubsea Safety Systems
Subsea Safety Systems The ELSA-HP has been developed to service the high pressure horizontal tree completion and intervention market. With systems designed and qualified up to 15,000 psi, 250 degf and
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More information*NOTE: 75 OHM SERIES CONNECTORS ARE NOT INTERMATEABLE WITH THE 50 OHM SERIES.
The Connex N connectors with screw coupling are fully interchangeable with N connectors made to the MIL-C-39012 specification. Designed for use in all systems where very good R.F. and mechanical performance
More informationMODEL DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT
MODEL 863-000-200 DIGITAL ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.5 TO 100FT (0.15 TO 30M) OPERATING RANGE SERIAL OUTPUT DOCUMENT NO. 430-017C April 14, 2005 S/N IMAGENEX TECHNOLOGY CORP. 209-1875
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk WIRE ROPE CUTTER WCS75HDZ PRODUCT CODE No. 980482 INSTRUCTIONS FOR
More informationSELTEC FZC. OFFSHORE & SUBSEA TECHNOLOGY
SELTEC FZC. www.seltecuae.com OFFSHORE & SUBSEA TECHNOLOGY The Company Carl Kurt Walther GmbH & Co. KG was founded in 1931 as a mechanical engineering company in Wuppertal. Since 1951, the WALTHER PRÄZISION
More informationPegasus Series Amphenol Pcd
Pegasus Series Amphenol Pcd Amphenol Pcd is one of the world s leading suppliers of interconnect products for Military, Commercial Aerospace and Industrial applications. Located north of Boston in Beverly,
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk WIRE ROPE CUTTER RCO40 PRODUCT CODE No. 980502 INSTRUCTIONS FOR INSTALLATION,
More informationSATURNSERIES INTERCHANGE > ISO (for the couplings)
Saturn Block INTERCHANGE > ISO 16028 (for the couplings) PATENTED ISO 16028 TECHNICAL FEATURES AND OPTIONS Interchange ISO 16028 (for the couplings) Sealing description Nitrile NBR Connection system Push
More informationPolatrak ROV II - Tip Contact Probe Operation Manual
This PDF document contains Live Web Links Click them for more information from the web Polatrak ROV II - Tip Contact Probe Operation Manual A Cathodic Protection Probe with dual Ag/AgCl reference cells
More informationFTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL
FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL TABLE OF CONTENTS PRODUCT OVERVIEW 2 I - USE AND CARE: 3 II - INSTALLATION: 5 III - GENERAL MAINTENANCE TIPS: 5 IV - APPENDIX: A-1 2-WIRE CURRENT LOOP
More informationPULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING
PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering
More informationCP10 Sensor Installation and Maintenance Instructions
4030150/9 IM-P403-26 EMM Issue 9 CP10 Sensor Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Maintenance 5. Spare parts Copyright 2017
More information5k Slickline Lightweight Pressure Control Equipment 4 ID
5k Slickline Lightweight Pressure Control Equipment 4 ID Table of Contents 5k Slickline Lightweight Pressure Control Equipment 4 ID... 1 Hydraulic Slickline Stuffing Box... 3 Wireline Lubricators... 4
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HP690A Intensifier Panel including the following versions: Model Intensification
More informationDIVERLESS SUBSEA HOT TAPPING OF PRODUCTION PIPELINES
DIVERLESS SUBSEA HOT TAPPING OF PRODUCTION PIPELINES Dale Calkins Senior Project Engineer, TD Williamson Inc Biography Dale Calkins joined TD Williamson Inc in November of 1999 after working as a consulting
More informationCOOPER POWER SERIES. DS250 deadbreak straight connector installation instructions interface A. Connectors MN650027EN
Connectors MN650027EN Effective November 2016 Supersedes January 2014 (IS550-11-1) DS250 deadbreak straight connector installation instructions interface A COOPER POWER SERIES DISCLAIMER OF WARRANTIES
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationTotal Pressure Regulator Solutions.
Total Pressure Regulator Solutions www.pressure-tech.com Working with customers to support their exact needs A pressure regulator is a critical component in any fluid control system. At Pressure Tech,
More informationINDEX OF REVISIONS DESCRIPTION AND/OR AFFECTED SHEETS
E&P-CORP/ ENGP/ISP TECHNICAL SPECIFICATION I-ET-3500.00-1500-896-PAZ-002 Rev. 0 E&P Pag. 1 / 13 UN-BC e UN-RIO SUBSEA CONTROL UMBILICAL (Manifold Standard) INDEX OF REVISIONS REV DESCRIPTION AND/OR AFFECTED
More informationRapidmain Installation Guide
Rapidmain Installation Guide Aluminium Compressed Air Pipe Work Installation Guide Trafalgar Court, Waterloo Ind Estate, Widnes Cheshire. UK. Ref: Rapidmain installation guide 4b Index 1. Rapidmain fittings:
More informationTypes and approvals. Page 1/6. Data Sheet
Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description
More informationDIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG
DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG 2009 Interspiro AB, Sweden. This publication contains or refers to proprietary information which is protected by copyright. All rights are
More informationAutoChanger Installation & User Guide Issue 2
1 INDEX Page 1. Introduction... 3 2. AutoChanger Components Guide 4 3. Installation. 5-11 a) Installation Guidelines.. 5 b) Installation Retrofit... 6-11 c) Installation New... 11 4. AutoChanger User Guide
More informationCheck with local zoning official for property line distance requirements.
RESIDENTIAL POOL PLAN SUBMITTAL GUIDELINES The following guidelines are intended to assist municipal residents with the permit acquisition process with regard to pools, spas and hot tubs for single family
More informationCOOPER POWER SERIES. DE250 deadbreak elbow connector installation instructions interface A. Screened Separable Connectors MN650025EN
Screened Separable Connectors MN650025EN Effective November 2016 Supersedes September 2013 (IS550-10-1) DE250 deadbreak elbow connector installation instructions interface A COOPER POWER SERIES DISCLAIMER
More informationSMB/SMC Coaxial Connectors
The Amphenol SMB/SMC subminiature coaxial connectors with 50 ohm impedance are for applications to 4 GHz (SMB) or 10 GHz (SMC). Generally less expensive then SMA, these connectors are used primarily in
More informationPRODUCT SPECIFICATION. SFP+ Cage and Cage Assembly 1 of 8 A
SFP+ Cage and Cage Assembly 1 of 8 A 1.0 Objective This specification defines the performance, test, quality and reliability requirements of the _Small Form-factor Pluggage (SFP+) product. 2.0 Scope This
More informationCVI Valve Line. Exceeds the industry s highest standards for reliability and performance
CVI Valve Line Exceeds the industry s highest standards for reliability and performance Available in the most standard models with the shortest lead times in the industry Exceptional quality every CVI
More informationSubsea Tooling Services Range of Dredgers
Subsea Tooling Services Range of Dredgers Subsea Tooling Services UK Ltd (STS) has a large selection of ROV / Diver operated dredgers. The range includes 3 4 6 8 10 and 12 dredgers. We are confident we
More informationCONTENTS PAGE. Introduction... HUM 2 Availability... HUM 2 Applications... HUM 2
CONTENTS PAGE SECTION PAGE erjjboseries Introduction... HUM 2 Availability... HUM 2 Applications... HUM 2 Testing... HUM 2 Part Number System... HUM 2 General Information... HUM 2 Ampacity Chart for Standard
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationEASIDEW TRANSMITTER with Current Source Output
EASIDEW TRANSMITTER with Current Source Output INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue March 2002 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element
More informationFlorida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement
Board of Rules and Appeals FBC 6 th Edition (2017)- Residential - Supplement No. 1 January 1, 2018 Florida Building Code 6 th Edition (2017) Residential File removed pages for reference. Broward County
More informationCOMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW
COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW JUN 200 CONTENTS: SECTION TITLE PAGE Description of Connector and Intended Application 2 2 Marking of Connector and/or Package 2 3 Ratings
More informationCONTENTS PAGE. Introduction... CSMS 2 Availability... CSMS 2 Applications... CSMS 2
CONTENTS PAGE SECTION PAGE `pjjpseries Introduction... CSMS 2 Availability... CSMS 2 Applications... CSMS 2 Testing... CSMS 2 Special Assemblies... CSMS 2 Part Number System... CSMS 2 General Information...
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationAnderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions
Before installation these instructions must be fully read and understood Installation and maintenance instructions for Series 93 Positive Pressure Pilot Operated Safety Relief Valves (POSRV). The intent
More informationPURA. Pure Gas Dewpoint Transmitter. Users Guide
PURA Pure Gas Dewpoint Transmitter Users Guide Issue January 2003 Page 2 Table of Contents SECTION PAGE 1 Product Overview 3 2 Preparation 3 3 Installation 3 3.1 PURA Premium & OEM Dewpoint Transmitter
More informationSEMME2135 Assisting in modifying and adding electrical circuits in yachts and boats
Assisting in modifying and adding electrical circuits in yachts and boats Overview This standard identifies the competences you need to assist with the modification or addition of electrical circuits in
More informationGM Series Dual-Block Multi-Function Gas Control Valves
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series
More informationPreferred Instruments Danbury, CT USA
Tank Level Sensor Model TG-EL-WF-xx Installation & Operation Instructions SDI-TG-EL-WF March 6, 2006 Preferred Instruments Danbury, CT USA www.preferredinstruments.com CONTENTS Installation Pg. 2 Calibration
More informationINDEX OF REVISIONS DESCRIPTION AND/OR AFFECTED SHEETS
E&P-ENGP/IPMI/ES TECHNICAL SPECIFICATION I-ET-3500.00-1500-896-PAZ-010 Rev. 0 E&P Pag. 1 / 13 UN-BC, UN-ES, UN-RIO SUBSEA ELECTR. POWER & CONTROL UMBILICAL This Technical Specification applies for umbilicals
More informationATS430 turbidity sensor Retractable insertion assembly
A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion
More informationC&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.
C&G 2395 Exam Paper June 2013 Section A-All questions carry equal marks. Answer all three questions. Show all calculations. 1. The electrical installation in an industrial unit is scheduled for a periodic
More informationSubsea Tooling Services Range of Dredgers
Subsea Tooling Services Range of Dredgers (STS) has a large selection of ROV / Diver operated dredgers. The range includes 3 4 6 8 10 and 12 dredgers. We are confident we have a dredger that will suit
More informationHT Series. 1500kW to 5500kW
HT Series 1500kW to 5500kW HamiltonJet HT Series. HamiltonJet HT series waterjets represent the next evolution in waterjet propulsion technology. Developed from the highly successful HamiltonJet HM waterjet
More informationP9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6
P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationPRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
More informationInfrared Linescanners
Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories LSPHD Mountings and Accessories
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk SOFT LINE CUTTER SL55 PRODUCT CODE No. 980504 INSTRUCTIONS FOR INSTALLATION,
More informationGFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features
Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma
More informationACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION
Application Note Doc. G8108-001 Rev. A - 23-Jul-02 ACCURACY, PERFORMANCE, AND HANDLING OF OIL-FILLED DIGIQUARTZ PRESSURE INSTRUMENTATION For more information regarding Digiquartz products contact: Paroscientific,
More informationPressure and Vacuum Switches for Process Applications
for Process Applications Form 216 SOR Pressure are rugged field-mounted instruments. The pressure sensing element of the SOR pressure switch is a force-balance, piston-actuated assembly. The sensing element
More informationThe Push-fit Solution for Blown Fibre & Cable Systems
The Push-fit Solution for Blown Fibre & Cable Systems January 2017 Quality Manufacture The John Guest Group has a long established reputation as a world leading manufacturer of push-fit fittings, tube
More informationEMERGENCY PIPELINE REPAIR SYSTEMS DEVELOPED TO FACILITATE PIPELINE REPAIR OF UNPIGGABLE DEFECTS. By: Dale Millward, STATS Group, United Kingdom
EMERGENCY PIPELINE REPAIR SYSTEMS DEVELOPED TO FACILITATE PIPELINE REPAIR OF UNPIGGABLE DEFECTS By: Dale Millward, STATS Group, United Kingdom Introduction The term Double Block and Bleed is mostly used
More informationjáåêçtbqj`lkpmifqseries
UNDERWATER ELECTRICAL WET-MATE CONNECTORS CONTENTS PAGE SECTION PAGE tbqj`lkpmifqseries Introduction... MWC 19 Availability... MWC 19 Applications... MWC 19 Testing... MWC 19 Special Assemblies... MWC
More informationMULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE
SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous
More informationOperating Procedure TITON SUBSEA BOLT TENSIONER
Operating Procedure TITON SUBSEA BOLT TENSIONER B & A Hydraulics Ltd Block 1, Units 1 & 2 Souter Head Industrial Centre Souter Head Road Altens Aberdeen Phone: 01224 898955 Fax: 01224 898787 E-Mail: TITON@bahyd.co.uk
More informationQUICK START GUIDE CB-450 DATA BUOY PLATFORM
What s Included (1) Buoy hull with data well, 450 lb buoyancy (1) Buoy tower (3) 10W Solar panels (1) Data well lid (isic-cb or pass-through) (3) Top-side lifting eyes (3) Bottom-side mooring eyes (1)
More informationTITAN 4. The Industry Standard for Seven-Function Dexterous Manipulators
TITAN 4 Manipulator Systems The Industry Standard for Seven-Function Dexterous Manipulators Hundreds of TITAN 4 manipulator systems are in use worldwide every day. TITAN manipulators are the highest quality
More information2-port seat valves PN25 with externally threaded connections
4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
More informationAllspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)
Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk SOFTLINE CUTTER SL80 PRODUCT CODE No. 980248 INSTRUCTIONS FOR INSTALLATION,
More informationHyquest Solutions Pty Ltd
INSTRUCTION MANUAL BUBBLERS MODELS HS23SL / HS23DL / HS23DO QUALITY SYSTEM ISO: 9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.)
More information3.0 Pressure Transmitter Selection
3.0 Pressure Transmitter Selection Each Tronic Line pressure transmitter has different features to meet specific performance, environmental, and price requirements. It is not possible to describe every
More informationБерг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC.
Turning Ideas Into Engineered Solutions RING & SEAL, INC. K-CBS Series Circumferential Barrier Seals Kaydon s high performance circumferential barrier seals back up DGS systems with performance & economy.
More information