Application Note. ASTRON Remote Plasma Source Ignition Best Practices PROBLEM

Size: px
Start display at page:

Download "Application Note. ASTRON Remote Plasma Source Ignition Best Practices PROBLEM"

Transcription

1 PROBLEM The ASTRON family of remote plasma sources produce reactive gas species for semiconductor device fabrication applications. Reliable ignition of the plasma in the ASTRON depends strongly on the ambient conditions under which the plasma is being struck. Predictable ignition of the plasma can only be achieved when the ignition sequence for the plasma is appropriate for the process conditions and equipment configuration employed in a particular process. BACKGROUND ASTRON is a family of self contained, lid-mountable remote plasma sources that produce reactive downstream chemistries. These sources create reactive gas streams by the passage of precursor gases such as through MKS Instruments patented low-field toroidal plasma technology. ASTRON sources may be installed in a wide variety of configurations on Si wafer or large-area substrate process chambers. ASTRON sources have proven to be effective and economical in providing the reactive gases needed for CVD chamber clean, FPD chamber clean, solar chamber clean, photoresist bulk ash, oxidation, nitridation, and chemical abatement. The best results in the cleaning and other processes that use ASTRON sources can only be assured when reliable and predictable plasma ignition occurs in the process. There are several equipment and process configuration factors that will influence the predictability of the plasma ignition process. Reliable and accurate sensing of the process condition is critical for repeatable operation. Pressure and temperature within the equipment configuration must be accurately known in order to program the system to achieve repeatable plasma ignition. Any materials that are exposed to the reactive gas must be compatible with the harsh environment, otherwise component failure and subsequent leakage of air into the system can occur. The presence of air in the plasma gas will impact the conditions necessary to achieve ignition. Other contaminants in the gas used for plasma can shift the ignition conditions in the system and negatively affect reliable ignition. In addition, damage to materials caused by overheating in the system can produce leakage with concomitant degradation of ignition performance. ASTRON Remote Plasma Source Ignition Best Practices Typical ASTRON Ignition Sequence Figure 1 shows a typical equipment configuration that might employ an ASTRON remote plasma source. The following steps would constitute a typical ignition sequence for this system: 1) Initially, the Ar plasma gas flow is set to 1-4 slm and the pressure, as measured at the ASTRON plasma block exit, stabilized at 1-4 Torr. Flow and pressure specifications may differ depending on the ASTRON model (Table 1). Furthermore, depending on the gas conductance characteristics of the transport region in Figure 1, a significant pressure differential may exist between ASTRON source and the process chamber. Only careful selection and correlation of the process chamber pressure to the ASTRON source pressure, or the use of pressure readings taken close to the ASTRON source can ensure reliable ignition conditions. Model Ar Flow (slm) Pressure (Torr) ASTRON ASTRON i ASTRON e/ex ASTRON hf ASTRON hf-s ASTRON hf ASTRON G6/G Table 1 - Recommended Flow and Pressure for ignition on various ASTRON units Note: Pressure is measured at ASTRON unit exit flange 2) Once gas flow and pressure are stabilized, the operator sends a Plasma Enable signal to the ASTRON that initiates a series of automatic actions: a. The system applies power to an ignition assembly to initiate gas breakdown. b. The induced electric voltage in the plasma channel is raised, forming a toroidal plasma. c. The spark plug voltage is then disconnected and the power supply transitioned from ignition state to steady state by lowering the plasma loop voltage and raising plasma current. d. The plasma status (Plasma On and other information) is reported to the control system.

2 Page 2 BACKGROUND (CONT.) 3) The cleaning gas, typically, is then introduced and smoothly increased to the desired flow and pressure while simultaneously changing or eliminating argon if desired. This application note describes the best practices that can be used to ensure reliable ignition performance for the following ASTRON remote plasma sources: SOLUTION ASTRON (2L) ASTRON i (3L) ASTRON e/ex (4-8 L) ASTRON hf (15 L) ASTRON hf-s (15 L) ASTRON hf+ (22 L) Equipment Best Practice ASTRON G6/G7 (30 L) Properly executed system design can assure ignition predictability and success since there are certain components in an equipment configuration that can strongly impact ignition performance. These components include the transport device, chamber flange, and the gas distribution device (i.e. a baffle, a single-stage showerhead, or a multi-stage showerhead; see Figure 1). Following the guidelines below can help in avoiding common ignition problems and other process issues. 1) Materials Compatibility: Contamination due vacuum leaks or the corrosion of chamber components degrades ignition performance and other process characteristics. All materials in the system, including the transport device, flanges, O-rings, baffle or showerhead, vacuum valves, exhaust lines, as well as the chamber itself, must be compatible with the active gas. For example, stainless steel corrodes and Viton O-rings decompose when exposed to atomic fluorine. Aluminum is the metallic process chamber material of choice for active fluorine environments, and perfluorelastomer O-rings are more resistant than Viton to fluorine attack. Additionally, reactive gas recombination, thermal compatibility, and process contamination must be carefully considered when selecting system materials. To minimize activated gas recombination upstream of the chamber, use proper materials (i.e. aluminum for atomic fluorine), avoid sharp bends and keep the transport device as short as possible. 2) Gas Purity: The ASTRON source requires high purity argon as the working gas for plasma ignition. MKS validates ignition performance using % (Grade D) Argon and recommends this purity (or better) for the ignition gas; any contamination by electronegative gases (i.e. oxygen due to leakage or process gas residues due to poor purging) will reduce the probability of successful ignition. Therefore, the gas delivery system must be designed to avoid any contamination of the ignition argon by other gases. This can be accomplished, for example, by valving off all other process gases during the ignition cycle. Note that flow controllers ARE NOT shut-off valves - do not rely on them to completely stop any gas flow; particularly for high flow ASTRON units, the use of the flow control component for gas shut-off can allow electronegative process gases such as into the ASTRON chamber. Gas delivery designs must also provide provisions to purge gas delivery lines to eliminate residual air and adsorbed water after the line has been opened to ambient or to remove residual process gas (e.g. ) prior to introducing the argon gas in an ignition cycle. Note that, in the presence of silicon product wafers, the purity of argon is dictated by the needs of the product; this may be significantly higher than that needed for chamber etching/cleaning. Figure 1 - Typical ASTRON remote plasma source setup

3 Page 3 3) Gas Temperature: Since the activated gas exiting the ASTRON source transports a significant amount of heat and chemical energy (up to 500 W per slm of inlet gas) throughout the equipment gas path, it is good practice to monitor the equipment/gas temperature at a number of different downstream locations during initial equipment design testing. System overheating can damage seals, destroying leak integrity. For example, flange O-rings, may fail and leak if overheated. Active water cooling should be added to any areas at risk of material failures or burn hazards due to high gas temperatures. 4) System Pressure Differentials: Showerheads or baffles can create a significant pressure differential between the gas exit of the ASTRON source and the process chamber, where the pressure is typically measured. Because of the harsh chemical and thermal conditions that exist at the ASTRON exit, it is usually neither convenient nor desirable to monitor the pressure at this point. Instead, modeling or experimentation employing an inert gas at equivalent flows should be used to establish a reliable correlation between the ASTRON pressure and the process chamber pressure. 5) ASTRON Source Contamination: The adsorption of certain gases such as fluorine or CVD precursors on the interior surfaces of the ASTRON source may impede plasma ignition. Typically, electronegative process gases adsorbed in this manner exhibit the largest negative effect. While a purge gas can provide some protection for the ASTRON internal surfaces, in certain cases it may be necessary to install an isolation valve between the ASTRON and process chamber. Processes that use liquid precursors, in particular, benefit from an isolation valve. Since the location for this isolation valve experiences harsh conditions of temperature and reactive gas concentrations, only valves that can be properly cooled and that have components made from compatible materials e.g., fluorine-resistant O-rings should be used. Note 1: To determine pressure drop experimentally, add a second pressure measurement device to the transport device as close to the ASTRON exit as possible (see below). Flow inert gas through the ASTRON and record both chamber and ASTRON exit pressures. To correlate inert gas flow to, assume the latter completely dissociates to F and N atoms, with half the N recombining to N 2. For example, to reproduce the pressure drop associated with 4 slm of, use 15 slm of argon or N 2, to replicate the following condition: Note 2: Chamber Pressure ASTRON Exit Pressure P2 4 12F + 2N + N 2 P1 Gas Inlet Substrate ASTRON Transport Region (Cooling Jacket) Gas Baffle Process Chamber Figure 2 - Schematic for setup to determine the pressure drop between the ASTRON remote plasma source and the process chamber In this application note and in any ASTRON specifications, the pressures cited always refers to the pressure at the ASTRON outlet and does not consider any system-dependent pressure drops.

4 Page 4 Cleaning Process Best Practice A properly designed cleaning recipe can help to ensure successful plasma ignition. The use of the following guidelines can significantly increase the ignition success rate in an ASTRON plasma source that has been properly installed on a process chamber: Note: Even those steps that may seem unnecessary after limited testing in a controlled lab setting will increase the ignition success rate on a fleet of systems installed in a wide variety of manufacturing facilities. Therefore, always employ all of the steps defined below. Figure 3 - Pressure trace for a typical chamber clean 1) Allow sufficient stabilization time in the ignition step of the process recipe. The actual time needed for stabilization will depend on the characteristics of the gas delivery and process chamber pressure control components of the system. Figure 3 shows a typical trace for pressure stabilization in a process chamber where the pressure can be seen to stabilize over time following a set point change. During the development of the process recipe, monitor the pressure as a function of time following a step change. Fully characterize the dynamic pressure response of your process chamber configuration, and select a stabilization time that results in successful ASTRON ignition 100% of the time. The stabilization time can also be used for purging the system of residual trace gases that might impede ignition. Ensure that the purge flow is sufficient to adequately purge the environment in the time allowed. If using flow and/or pressure feedback control with a stabilization end point make sure the endpoint is not triggered during oscillations associated with overshoot. Attempting to ignite during a dynamic step, for example, while gas flow is ramping from one setpoint to another, may result in ignition delays or faults. Although the latter process will typically work on the original system on which it was developed, it will not be robust over time on a large number of systems. 2) Following pressure stabilization and ignition, the system should transition smoothly to the cleaning process. During this step, large gas bursts that may occur on introduction of the or other cleaning gas must be avoided since this could extinguish the plasma. Such bursts can occur when opening gas line valves if an upstream flow controller is fully open, for example. Plasma may also extinguish if the ignition argon flow ceases before the cleaning gas ramps to a level sufficient to sustain plasma. One effective method for avoiding these issues is the use of a 3-step transition in which each step lasts a few seconds: a. with the ignition argon flowing, introduce the cleaning gas at 1/3 of the target flow; b. turn the argon flow off; ramp the cleaning gas flow to 2/3 of the target value; c. ramp the flow of the cleaning gas to its final target value. 3) It is good practice to transition back to argon and continue running argon plasma for several seconds after completing the chamber clean. This is due to the fact that residues from the electronegative cleaning gas can impede the next ignition and a post-clean argon purge/ plasma step can remove these residues. Use the same pressure/flow condition in the post clean step as that employed during ignition.

5 Page 5 4) The remote plasma source should be purged during the chamber deposition or etch process. This prevents backstreaming by unwanted process gases from the process chamber into the ASTRON plasma block. Such gases can adsorb on ignition assembly components and impede ignition. To avoid this, flow an inert gas, preferably Ar, during process steps in which the ASTRON is not operating. Gas flow need only be sufficient to maintain the ASTRON plasma block at a higher pressure than that of the process chamber; often no more than 0.5 slm is necessary. If there is a risk that the inert gas might interfere with the process, purge with a carrier gas, such as N 2 or H 2. Contact MKS applications for an assessment of any other purge gases. 5) Examples of cleaning recipes for each model are shown below: Models 1 Pre-Ignition 2 Ignition ASTRON (2L) 3 Transition 1 4 Clean 5 Post Purge Ar (slm) 2 Same as step 1 Same as step 1 Same flow as 1-4 (slm) 0 0 1/2 of Total flow final flow 0 Press (Torr) 2.0 Same as step Same as step 1 ASTRON Off On On On On Time (seconds) > 10 s Up to 40 5 As required > 10 s Models 1 Pre-Ignition ASTRON i (3L) and ASTRON e/ex (4-8 L) 2 Ignition 3 Transition 1 4 Clean 5 Post Purge Ar (slm) 2 Same as step 1 Same as step (slm) 0 0 1/2 of Total flow final flow 0 Press (Torr) 2.0 Same as step Same as step 1 ASTRON Off On On On On Time (seconds) > 10 s Up to 40 5 As required > 10 s Models ASTRON hf (15 L), ASTRON hf-s (15 L), ASTRON hf+ (22 L) and ASTRON G6/G7 (30 L) 1 Pre-Ignition 2 Ignition 3 Transition 1 4 Transition 2 5 Clean 6 Post Purge Ar (slm) 1-4 Same as step 1 Same as step Same as step 1 (slm) 0 0 1/5 of Total flow 2/3 of Total flow final flow 0 Press (Torr) 1-4 Same as step Same as step 1 ASTRON Off On On On On On Time (seconds) > 10 s Up to As required > 10 s

6 Page 6 Maintenance and Troubleshooting Best Practice Ignition failures or delays may occur because of maintenancerelated factors. Listed below are some best practice maintenance procedures: 1) Following all maintenance procedures, leak-check the gas delivery and vacuum systems to ensure continuing high levels of gas purity within the ASTRON. A leak in the gas delivery line to the chamber will introduce air, water vapor, or other contaminants that can impede ignition. 2) Regularly calibrate all flow control and pressure measurement devices. This helps to reduce system-tosystem variation. 3) Allow the system to reset after a failed ignition attempt. The ASTRON will interrupt and reset if ignition has not occurred within its default time (up to 20 or 40 s, depending on the model). A Reset procedure may take as long as 80 s, during which time the unit will ignore all Plasma On commands. Always confirm that the unit displays Ready status before attempting another ignition. 4) Ignition may sometimes be more difficult under socalled cold-start conditions; that is, following an extended period during which the ASTRON has been idle. Residual vacuum species (or air if the unit has been vented) may adsorb on the ignition assembly during such idle periods. The following practices can help to avoid cold-start ignition delays. a. Maintain a constant low argon purge through the unit during long idles. b. During an extended idle periodically (approximately every minutes) ignite the unit and allow it to run at the ignition flow/pressure for ~2 minutes. Some systems include control settings that allow periodic running automatically. c. If an ASTRON does not ignite, purge it with the highest available argon flow for at least 1 minute, then stabilize the argon flow and pressure at the ignition values and attempt ignition. If ignition is still not successful, repeat the high-flow purge and attempt ignition at a different pressure within the specified ignition window (e.g., if ignition is not successful at 4 Torr, attempt ignition at 1 Torr). 5) A hardware malfunction may cause ignition failures. If the procedures above have not solved the problem, replace the unit: it may require repair by a qualified MKS service technician. CONCLUSION Following best practices in system design, process setup and maintenance procedures can improve ASTRON ignition performance and overall reliability. Mounting the ASTRON source close to the process chamber, using properly cooled, chemically compatible materials, and employing a stable, contamination-free gas delivery system are design best practices associated with reliable ignition. Using a robust process sequence, that includes a pre-ignition stabilization step, a smooth transition from ignition to the cleaning process, and a post-process purge step can also help ensure successful ignition in high volume manufacturing. For further information, call your local MKS Sales Engineer or contact the MKS Applications Engineering Group at ASTRON is a registered trademark of MKS Instruments, Inc., Andover, MA. Viton is a registered trademark of E.I. Dupont, Wilmington, DE. App. Note 04/11-7/ MKS Instruments, Inc. All rights reserved. MKS Global Headquarters 2 Tech Drive, Suite 201 Andover, MA (within USA)

Usage Policies Notebook for Xenon Difluoride (XeF 2 ) Isotropic Si Etch

Usage Policies Notebook for Xenon Difluoride (XeF 2 ) Isotropic Si Etch Usage Policies Notebook for Xenon Difluoride (XeF 2 ) Isotropic Si Etch Revision date September 2014 2 Emergency Plan for XeF 2 Si Etcher Standard Operating Procedures for Emergencies Contact information

More information

R I T. Title: STS ASE Semiconductor & Microsystems Fabrication Laboratory Revision: Original Rev Date: 01/21/ SCOPE 2 REFERENCE DOCUMENTS

R I T. Title: STS ASE Semiconductor & Microsystems Fabrication Laboratory Revision: Original Rev Date: 01/21/ SCOPE 2 REFERENCE DOCUMENTS Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the STS ASE. All users are expected to have read and understood this document. It is

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES

INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES INSTRUCTIONS FOR MODELS SG3897 AND SG3898 CROSS PURGE ASSEMBLIES THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE

More information

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL. SERIES 30 PROTECTOSEAL 1 2" NPT inlet and outlet standard Direct acting valve mechanism Optional flanged or threaded inlet and outlet connections available Inlet gas pressures from 10 PSIG to 200 PSIG

More information

STS ICP-RIE. Scott Munro (2-4826,

STS ICP-RIE. Scott Munro (2-4826, STS ICP-RIE LOCATION: Plasma Etch Area PRIMARY TRAINER: Scott Munro (2-4826, email@address.com) 1. OVERVIEW The STS ICP-RIE is available to users who require deep anisotropic silicon etching with near

More information

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION

BEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION BEST KNOWN METHODS Transpector XPR3 Gas Analysis System DESCRIPTION The Transpector XPR3 is a third-generation, quadrupole-based residual gas analyzer that operates at PVD process pressures and is the

More information

Technical Data Sheet MF010-O-LC

Technical Data Sheet MF010-O-LC Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the

More information

Optimizing Gas Supply for Industrial Lasers

Optimizing Gas Supply for Industrial Lasers Optimizing Gas Supply for Industrial Lasers Laser cutting of metals and other materials has grown rapidly due to developments in laser power, advancements in CNC automation, and decreasing costs. The industrial

More information

Oxygen Contamination

Oxygen Contamination MPMS Application Note 1014-210 Oxygen Contamination This application note describes potential sources for oxygen contamination in the sample chamber and discusses its possible effects. Molecular oxygen,

More information

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System) Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System) Revision date October 2014 2 Emergency Plan for Nano Furnace Standard Operating Procedures for Emergencies Contact information Person

More information

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS

RESOLUTION A.567(14) adopted on 20 November 1985 REGULATION FOR INERT GAS SYSTEMS ON CHEMICAL TANKERS INTERNATIONAL MARITIME ORGANIZATION A 14/Res.567 16 January 1986 Original: ENGLISH ASSEMBLY - 14th session Agenda item lo(b) IMO RESOLUTION A.567(14) adopted on 20 November 1985 THE ASSEMBLY, RECALLING

More information

Standard Operating Manual

Standard Operating Manual Standard Operating Manual ARC12M Sputter Copyright 11.2015 by Hong Kong University of Science & Technology. All rights reserved. Page 1 Contents 1. Picture and Location 2. Process Capabilities 2.1 Cleanliness

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

STS PECVD Instructions

STS PECVD Instructions STS PECVD Instructions I. Introduction A PECVD (Plasma Enhanced Chemical Vapor Deposition) reacts gases in a RF- (Radio Frequency) - induced plasma to deposit materials such as SiO 2 and Si X N Y. This

More information

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008

UNITY 2 TM. Air Server Series 2 Operators Manual. Version 1.0. February 2008 UNITY 2 TM Air Server Series 2 Operators Manual Version 1.0 February 2008 1. Introduction to the Air Server Accessory for UNITY 2...2 1.1. Summary of Operation...2 2. Developing a UNITY 2-Air Server method

More information

Improve Process Reliability

Improve Process Reliability Convenient Conductivity Calibration to Meet Pharmacopeia Regulations Pharmacopeias require that conductivity measurement systems be periodically calibrated to ensure their precision. The range of accessories

More information

Standard Operating Manual

Standard Operating Manual Standard Operating Manual Branson IPC 3000 O 2 Asher Page 1 of 14 Contents 1 Picture and Location 2 Process Capabilities 2.1 Cleanliness Standard 2.2 Recipes 2.3 Performance of Branson IPC 3000 O 2 Asher

More information

FT28_mks.qxp 21/11/ :06 Page 1

FT28_mks.qxp 21/11/ :06 Page 1 FT28_mks.qxp 21/11/2005 14:06 Page 1 The critical components of a production-worthy ALD system CRITICAL Jon Owyang, Jeff Bailey & Subrata Chatterji, Aviza Technology, Inc., CA, USA ABSTRACT Fundamentally,

More information

ACV-10 Automatic Control Valve

ACV-10 Automatic Control Valve ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,

More information

Standard Operating Manual

Standard Operating Manual Standard Operating Manual Branson IPC 3000 O 2 Asher Copyright 2014 by Hong Kong University of Science & Technology. All rights reserved. Page 1 Contents 1. Picture and Location 2. Process Capabilities

More information

5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts.

5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts. Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the PE4400. All users are expected to have read and understood this document. It is

More information

Leaks, contamination and closed loop control how RGAs make coating processes more profitable

Leaks, contamination and closed loop control how RGAs make coating processes more profitable Leaks, contamination and closed loop control how RGAs make coating processes more profitable Backup: What s an RGA Residual Gas Analyzer An instrument that is measuring the gas composition in a chamber

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Probe Instrument Regulator Model The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results. Laboratory Hardware Custom Gas Chromatography Solutions Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions

More information

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs.

Laboratory Hardware. Custom Gas Chromatography Solutions WASSON - ECE INSTRUMENTATION. Custom solutions for your analytical needs. Laboratory Hardware Custom Gas Chromatography Solutions Custom solutions for your analytical needs. Laboratory Hardware Wasson-ECE Instrumentation offers hardware-only solutions for advanced chromatography

More information

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features

Vortex flowmeters. Product family introduction Principle of operation Product review Applications Key product features Vortex flowmeters introduction Product review s Key product features This document should not be duplicated, used, distributed, or disclosed for any purpose unless authorized by Siemens. Page 1 Vortex

More information

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background

3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G Background 3-Way Decoking Valve Option - Installation and Operation Instructions Accessory G6600-60058 Background Accumulation of contaminants, such as column bleed, impurities in detector gases and even carbon from

More information

Notes-PECVD: Chamber 1

Notes-PECVD: Chamber 1 plasmatherm (EML) STANDARD OPERATING PROCEDURE CORAL Name: Plasmatherm Model Shuttlelock System VII SLR-770/734 Number: Location: EML What it Deposits the following films via Plasma-Enhanced Chemical Vapor

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,

More information

OPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9

OPERATION. Estimated kerf width compensation. HPR260 Manual Gas Instruction Manual 4-9 Estimated kerf width compensation The widths in the chart below are for reference. Differences between installations and material composition may cause the specific user results to vary from those shown

More information

Indian Institute of Technology Kanpur Samtel Centre for Display Technologies

Indian Institute of Technology Kanpur Samtel Centre for Display Technologies Fax: + 91-0512-2596620 Phones: + 91-0512-2596622,6088 Indian Institute of Technology Kanpur Samtel Centre for Display Technologies Enquiry number: SCDT/FlexE/2016-17/02 Date:05/05/2016 Sealed Quotations

More information

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS

INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS INSTRUCTIONS FOR MODEL SG6500 GAS HEATERS THIS BOOKLET CONTAINS PROPRIETARY INFORMATION OF ADVANCED SPECIALTY GAS EQUIPMENT CORP. AND IS PROVIDED TO THE PURCHASER SOLELY FOR USE IN CONJUNCTION WITH MODEL

More information

Petro-Chemical & Analyzer Sampling Systems

Petro-Chemical & Analyzer Sampling Systems Petro-Chemical & Analyzer Sampling Systems Pressure control solutions for your industry. The Tescom brand offers a comprehensive range of regulators, valves and changeover systems that are ideal for analyzer

More information

SF 6 Product Guide. Gas Analysis Instruments and Accessories

SF 6 Product Guide. Gas Analysis Instruments and Accessories SF 6 Product Guide Gas Analysis Instruments and Accessories Cambridge Sensotec Ltd specialises in the design and manufacture of gas analysis equipment under the Rapidox brand name. Based in the UK, the

More information

DESIGN AND INSTALLATION CONSIDERATIONS FOR TSI AEROTRAK VHP-RESISTANT REMOTE PARTICLE COUNTERS

DESIGN AND INSTALLATION CONSIDERATIONS FOR TSI AEROTRAK VHP-RESISTANT REMOTE PARTICLE COUNTERS DESIGN AND INSTALLATION CONSIDERATIONS FOR TSI AEROTRAK VHP-RESISTANT REMOTE PARTICLE COUNTERS APPLICATION NOTE CC-111 (A4) Introduction A widely used method to inactivate bio-contamination on surfaces

More information

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions L 100 Bubble-Tube Level System Installation, Operation and Maintenance Instructions Figure 1 Contents Section Description Page 1.0 Introduction 2 2.0 Specifications 3 3.0 Installation 3 4.0 Warranty 6

More information

Plasma Sources and Feedback Control in Pretreatment Web Coating Applications

Plasma Sources and Feedback Control in Pretreatment Web Coating Applications Plasma Sources and Feedback Control in Pretreatment Web Coating Applications Joseph Brindley, Benoit Daniel, Victor Bellido-Gonzalez, Dermot Monaghan Gencoa Ltd., Physics Rd, L24 9HP Liverpool, UK (+44)

More information

University of MN, Minnesota Nano Center Standard Operating Procedure

University of MN, Minnesota Nano Center Standard Operating Procedure Equipment name: STS Etcher Badger name: STS Revision number: 3 Model: 320 Revisionist: Paul Kimani Location: Bay 3 Date: 1 October 2013 A. Description The 320 is a manually loaded batch plasma etching

More information

BASICS of MAINTENANCE and TROUBLESHOOTING of VACUUM DIFFUSION PUMPS

BASICS of MAINTENANCE and TROUBLESHOOTING of VACUUM DIFFUSION PUMPS BASICS of MAINTENANCE and TROUBLESHOOTING of VACUUM DIFFUSION PUMPS Topics for Discussion Diffusion Pump Basics Maintenance Troubleshooting Topics for Discussion Diffusion Pump Fundamentals Maintenance

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer

OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer July 2011 OPERATOR S MANUAL Ar-Gone Weld Gas Analyzer WARNING! Before operating this product, read and understand this Operator s Manual. Become familiar with the potential hazards of this unit. Contact

More information

Improvements in the Reliability, Costs and Processing of WLP/RDL Circuits

Improvements in the Reliability, Costs and Processing of WLP/RDL Circuits Improvements in the Reliability, Costs and Processing of WLP/RDL Circuits Bill Moffat, Chief Executive Officer John Das, Ph.D., Process Engineer Wesley Lau, Senior Sales Engineer Kenneth Sautter, Senior

More information

Xactix XeF2 OPERATION MANUAL

Xactix XeF2 OPERATION MANUAL General Information The Xactix e-1 is a xenon difluoride (XeF 2) isotropic silicon etcher. XeF 2 is a vapor phase etch, which exhibits very high selectivity of silicon to photo-resist, silicon dioxide,

More information

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources

HOW TO NOT MEASURE GAS - ORIFICE. Dee Hummel. Targa Resources HOW TO NOT MEASURE GAS - ORIFICE Dee Hummel Targa Resources Introduction Measuring natural gas is both a science and an art. Guidelines and industry practices explain how to accurately measure natural

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.

More information

Petro-Chemical & Analyzer Sampling Systems

Petro-Chemical & Analyzer Sampling Systems Petro-Chemical & Analyzer Sampling Systems Pressure control solutions for your industry. The Tescom brand offers a comprehensive range of regulators, valves and changeover systems that are ideal for analyzer

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series

More information

Unaxis ICP/RIE SOP Revision 8 09/30/16 Page 1 of 5. NRF Unaxis ICP/RIE Etch SOP

Unaxis ICP/RIE SOP Revision 8 09/30/16 Page 1 of 5. NRF Unaxis ICP/RIE Etch SOP Page 1 of 5 NRF Unaxis ICP/RIE Etch SOP Unaxis Shuttlelock Reactive Ion Etcher with Inductively Coupled Plasma Module. Etch Capabilities: SiO2, Si3N4, Al, dielectrics and other commonly used materials.

More information

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4

More information

Operating Procedures for the. SAMCO ICP RIE System

Operating Procedures for the. SAMCO ICP RIE System Operating Procedures for the SAMCO ICP RIE System General Overview: The purpose of the SAMCO Model 200iP Inductively Coupled Plasma Reactive Ion Etcher (ICP RIE) is to etch III-V compound semiconductors

More information

RD(H)20/25 Pressure-Reducing Regulator User Manual

RD(H)20/25 Pressure-Reducing Regulator User Manual RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be

More information

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson

A Journal of Practical and Useful Vacuum Technology. By Phil Danielson A Journal of Practical and Useful Vacuum Technology From By Phil Danielson Thermal Conductivity Gauges Thermal conductivity pressure gauges are extremely common in vacuum technology, but an understanding

More information

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi

More information

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers 800 Series Mass Flow Meters and Controllers High Performance Mass Flow Meters and Controllers WHY MASS FLOW? In most processes it is mass, not volume, which is the critical variable. Volumetric flow measurements

More information

RAM Operation Manual

RAM Operation Manual RAM 4021-1 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-1 For Your Safety... 2 Description... 2 Setup Mode... 3 Lights/Alarms... 3 Operation... 4 Calibration...

More information

REPRODUCIBILITY IN OPTICAL THIN FILM PROCESSING PART 1, THE VACUUM AND PUMPING

REPRODUCIBILITY IN OPTICAL THIN FILM PROCESSING PART 1, THE VACUUM AND PUMPING ABSTRACT REPRODUCIBILITY IN OPTICAL THIN FILM PROCESSING PART 1, THE VACUUM AND PUMPING Ronald R. Willey Willey Optical, Consultants, 13039 Cedar Street, Charlevoix, MI 49720, USA Ph 231-237-9392, ron@willeyoptical.com

More information

APPLICATION NOTE. GC Integrated Permeation Device

APPLICATION NOTE. GC Integrated Permeation Device GC Integrated Permeation Device GC-integrated Design PPB to PPM Level Calibration No Cylinders or Regulators Required Option for Dual Ovens Cost Effective, Safe, Clean, Flexible, NIST Traceable Keywords:

More information

Model Series 62 Constant Differential Relay

Model Series 62 Constant Differential Relay Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION INTRODUCTION Model Series 62 Constant Differential Relay Rev 11 March 2011 Supersedes Rev 10 The Constant Differential Relay maintains a constant

More information

Standard Operating Manual

Standard Operating Manual Standard Operating Manual Allwin21 AW610 RTP Page 1 of 18 Contents 1 Picture and Location 2 Process Capabilities 2.1 Cleanliness Standard 2.2 Recipes 2.3 Performance of Allwin21 AW610 RTP 3 Contact List

More information

G96 Series BASOTROL Dual Operator Valve

G96 Series BASOTROL Dual Operator Valve Installation Instructions 9. Issue Date February 22, 2013 G96 Series BASOTROL Dual Operator Valve Applications The G96 valves are combination, dual operator, automatic valves available with or without

More information

WP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment

WP Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment Part 4 WP - 269 Eliminating Oxygen from the Purge Gas and the use of Monitoring Equipment Even using specialised weld purging equipment does not guarantee defect free welds. Control of the oxygen content

More information

6.6 Relief Devices. Introduction

6.6 Relief Devices. Introduction 6.6 Relief Devices Introduction Relief devices are used to help prevent a catastrophic failure of equipment and/or minimize the effects of any unanticipated or uncontrolled events. As such, relief devices

More information

PP-1, PP-1W, PP-2, & PP-3

PP-1, PP-1W, PP-2, & PP-3 Welker Pitot Probe Model PP-1, PP-1W, PP-2, & PP-3 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for the installation, operation, and maintenance

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

Bubble Tube Installations

Bubble Tube Installations Instruction MI 020-328 September 2013 Bubble Tube Installations For Liquid Level, Density, and Interface Level Measurements 2 Contents Introduction... 5 Abbreviations... 5 Principle of Operation... 5 Alternative

More information

Design DSA Steam-Atomized Desuperheater

Design DSA Steam-Atomized Desuperheater Instruction Manual DSA Desuperheater Design DSA Steam-Atomized Desuperheater Contents Introduction............................... 1 Scope of Manual......................... 1 Description..............................

More information

Plasma-Therm PECVD. Operating Characteristics. Operating Instructions. Typical Processes. I. Loading. II. Operating

Plasma-Therm PECVD. Operating Characteristics. Operating Instructions. Typical Processes. I. Loading. II. Operating Plasma-Therm PECVD A PECVD (plasma enhanced chemical vapor deposition) reacts gases in a RF (radio frequency) induced plasma to deposit materials such as silicon dioxide and silicon nitride. This PECVD

More information

Thermcraft Tube Furnace General Use

Thermcraft Tube Furnace General Use Page 1 of 9 Thermcraft Tube Furnace General Use The Thermcraft furnace is a general use, 3 zone tube furnace capable of reaching temperatures of 1200 C. The large 6 diameter quartz tube is capable of holding

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option MANUAL DIRECT PURGE OPTION UNION Instruments GmbH CWD2005 PLUS General information, safety standards and regulations for direct purge option Version: V1.00 Stand: 24.03.2010 Union Instruments GmbH Zeppelinstr.

More information

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax:

EASTERN ENERGY SERVICES PTE LTD. 60 Kaki Bukit Place #02-19 Eunos Tech Park Singapore, SG Singapore Telephone: Fax: 2 Table Of Contents 1. Introduction 3 2. About this Manual 3 3. Contacting YZ Systems 3 4. Vessel Components 4 5. Specifications 5 6. Application 6 7. Theory of Operation 7 8. DuraSite Installation & Use

More information

2 Sentry MCL Installation, Operation & Maintenance

2 Sentry MCL Installation, Operation & Maintenance Gas Liquid & Slurry Solid & Powder Steam & Water Installation, Operation & Maintenance Manual Original Instructions Liquid Sampling Manual Low-Emission Samplers S-GA-IOM-00249-7 11-17 Sentry MCL 966 Blue

More information

Series 203 Granville-Phillips Variable Leak Valve

Series 203 Granville-Phillips Variable Leak Valve Series 203 Granville-Phillips Variable Leak Valve Instruction Manual Instruction manual part number 203026 Revision B - November 2016 Series 203 Granville-Phillips Variable Leak Valve Customer Service

More information

CHEMICAL ENGINEERING SENIOR LABORATORY CHEG Initiated Chemical Vapor Deposition

CHEMICAL ENGINEERING SENIOR LABORATORY CHEG Initiated Chemical Vapor Deposition 1 CHEMICAL ENGINEERING SENIOR LABORATORY CHEG 4139 Initiated Chemical Vapor Deposition Objective: The objective of this experiment is to determine the effect of process variables on the deposition of thin

More information

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE ATEX CHEMISTRY DIAPHRAGM PUMPS. ATEX VARIO CHEMISTRY DIAPHRAGM PUMPS. Chemistry diaphragm pumps, vacuum systems and gauges for use in

More information

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G.

Plasma Cleaner. Yamato Scientific America. Contents. Innovating Science for Over 125 Years. Gas Plasma Dry Cleaner PDC200/210/510 PDC610G. Yamato Scientific America Innovating Science for Over 125 Years Plasma Cleaner Contents Gas Plasma Dry Cleaner PDC200/210/510 PDC610G Gas Plasma Reactor 145 146 147 149 144 Gas Plasma Dry Cleaner Plasma

More information

NGN Series nitrogen generator

NGN Series nitrogen generator NGN Series 8-64 nitrogen generator Applications how it works RK series 5-40 F Blanketing of Chemicals and Pharmaceuticals Gas Assisted Injection Moulding (GAIM) Laser Cutting Food Heat Treament of Ferrous

More information

SERIES 10. Pilot Operated Tank Blanketing Valve, 2" PROTECTOSEAL.

SERIES 10. Pilot Operated Tank Blanketing Valve, 2 PROTECTOSEAL. SERIES 10 PROTECTOSEAL 2" NPT inlet and outlet standard Pilot operated design provides tight operating band Optional inlet and outlet connections available Inlet gas pressures from 40 PSIG to 130 PSIG

More information

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

CRYOGENIC EXPERTS, INC. World Wide Web   Toll Free FOR CEXI Phone (805) Facsimile (805) CRYOGENIC EXPERTS, INC. World Wide Web http://www.cexi.com E-mail cexi@cexi.com Toll Free 1-800-FOR CEXI Phone (805) 981-4500 Facsimile (805) 981-4501 I. Installation Instructions Installation And Operating

More information

¾", 1", and 1 ¼" Integra Plus WS Manual and Pneumatic Valves

¾, 1, and 1 ¼ Integra Plus WS Manual and Pneumatic Valves ADVANCED MATERIALS HANDLING ¾", 1", and 1 ¼" Integra Plus WS Manual and Pneumatic Valves Excels in ultrapure bulk chemical and CMP slurry applications Entegris offers a complete line of valves specifically

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

MIL-STD-883G METHOD

MIL-STD-883G METHOD STEADY-STATE LIFE 1. PURPOSE. The steady-state life test is performed for the purpose of demonstrating the quality or reliability of devices subjected to the specified conditions over an extended time

More information

Standard Test Methods for Water Vapor Content of Electrical Insulating Gases by Measurement of Dew Point 1

Standard Test Methods for Water Vapor Content of Electrical Insulating Gases by Measurement of Dew Point 1 Designation: D 2029 97 (Reapproved 2003) Standard Test Methods for Water Vapor Content of Electrical Insulating Gases by Measurement of Dew Point 1 This standard is issued under the fixed designation D

More information

Plasma Asher: March PX-500 User guide (May-30, 2017)

Plasma Asher: March PX-500 User guide (May-30, 2017) Plasma Asher: March PX-500 User guide (May-30, 2017) This is a highly versatile plasma etch tool that can etch using a direct plasma configuration (Oxygen plasma cleaner), a downstream plasma (Remote plasma),

More information

M-06 Nitrogen Generator (Nitrogen Making Machine)

M-06 Nitrogen Generator (Nitrogen Making Machine) Guideline No.M-06 (201510) M-06 Nitrogen Generator (Nitrogen Making Machine) Issued date: 20 th October, 2015 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains

More information

Related Products: Auto Drain Valve. Model/Specifications. Model

Related Products: Auto Drain Valve. Model/Specifications. Model Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl

More information

Rate of Flow Valve Series 120

Rate of Flow Valve Series 120 SPECIFICATIONS Rate of Flow Valve Series DIMENSIONS The OCV Series 120 Rate of Flow control valve is designed to control or limit flow to a predetermined rate, regardless offl uctuations in downstream

More information

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound. MACH ONE MASS FLOW CONTROLLER MACH ONE SERIES flow control MASS FLOW CONTROLLERS at the speed of sound. MACH ONE SERIES MASS FLOW CONTROLLER FLOW CONTROL AT THE SPEED OF SOUND The Mach One revolutionary

More information

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller

Pressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller w w w. m k s i n s t. c o m Pressure & Vacuum Measurement Solutions Series 370 Stabil-Ion Vacuum gauge and Controller Features & Benefits All-metal, rack-mount controller for Stabil-Ion and Convectron

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA

SSI Solaris 150 RTA Revision /27/2016 Page 1 of 9. SSI Solaris 150 RTA Page 1 of 9 SSI Solaris 150 RTA The Solaris 150 RTA is a rapid thermal annealing system capable of handling sample sizes up to 100mm (4 diameter) or smaller. The system can anneal in N 2 and Forming gas

More information

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection

Type 1367 High-Pressure Instrument Supply System with Overpressure Protection Instruction Manual D100343X012 Type 1367 November 2017 Type 1367 High-Pressure Instrument Supply System with Overpressure Protection TYPE 252 FILTER 2ND-STAGE TYPE 67CF FILTER-STYLE REGULATOR INLET TYPE

More information

Standard Operating Manual

Standard Operating Manual Standard Operating Manual Oxford Plasmalab 80 Plus Plasma Etcher Page 1 of 24 Contents 1. Picture and Location 2. Process Capabilities 2.1 Cleanliness Standard 2.2 Available Etching Materials 2.3 Performance

More information

Scott Veirs September Safety and Environmental Impact for SubFab Operations

Scott Veirs September Safety and Environmental Impact for SubFab Operations Scott Veirs September - 2014 Safety and Environmental Impact for SubFab Operations In Collaboration with GLOBALFOUNDRIES New Leader in Foundry Technologies Fab 8, Malta NY 1 Motivation Ensure customer

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information