LIQUID PUMPS ACCESSORIES OVERVIEW

Size: px
Start display at page:

Download "LIQUID PUMPS ACCESSORIES OVERVIEW"

Transcription

1 LIQUID PUMPS ACCESSORIES OVERVIEW

2 INDEX Pulsation damper, FPD 06 3 Pulsation damper, FPD 10 4 Pulsation damper, UFPD 06 5 Pulsation damper, UFPD 10 6 Pressure control valves, FDV 30 7 Pressure control valves, FDV Pressure control valves, UFDV 30 9 Pressure control valves, UFDV Filters 11 Electrics and Electronics 12 Mounting options 14 Hoses and hydraulic connectors 15 2

3 Pulsation damper, FPD 06 KNF diaphragm pulsation dampers can effectively reduce the pulsation after the pump by up to 97%. Please note that the type of pulsation damper selected and the correct installation are essential in ensuring an optimal performance. FPD 06 ALLOWED PRESSURE 2 BAR Orifice for pump type FPD 06 KPZ D 0.7 NFB 5 KP / FPD 06 KPZ D 1.0 NF 5 RP / FPD 06 KPZ D 1.2 NF 10 / 25 KP / NFB 25 KP / FPD 06 KPZ D 1.4 NF 30 / NF 60 KP / FPD 06 KPZ D 1.8 NF 100 KP / FPD 06 KP.51Z D 1.4 NF 30 / NF 60 KP / FPD 06 KTZ D 0.7 NFB 5 KT / FPD 06 KTZ D 1.0 NF 5 RT / FPD 06 KTZ D 1.2 NF 10 / 25 KT / NFB 25 KT / FPD 06 KTZ D 1.4 NF 30 / NF 60 KT / FPD 06 KTZ D 1.8 NF 100 KT / FPD 06 TTZ D 0.7 NFB 5 TT / FPD 06 TTZ D 1.0 NF 5 RT / FPD 06 TTZ D 1.2 NF 10 / 25 TT / NFB 25 TT / FPD 06 TTZ D 1.4 NF 30 / NF 60 TT / FPD 06 TTZ D 1.8 NF 100 TT / FPD 06 KPZ FPD 1.06 ALLOWED PRESSURE 6 BAR Orifice for pump type FPD 1.06 KPZ D 0.7 NF 1.5 KP / FPD 1.06 KPZ D 1.0 NF 1.11 KP / FPD 1.06 KPZ D 1.2 NF 1.25 RP / FPD 1.06 KPZ D 1.4 NF 1.60 KP / FPD 1.06 KTZ D 0.7 NF 1.5 KT / NF 1.30 KT / FPD 1.06 KTZ D 1.0 NF 1.11 KT / FPD 1.06 KTZ D 1.2 NF 1.25 RT / FPD 1.06 KTZ D 1.4 NF 1.60 KT / FPD 1.06 TTZ D 0.7 NF 1.5TT / NF 1.30 TT / FPD 1.06 TTZ D 1.0 NF 1.11 TT / FPD 1.06 TTZ D 1.2 NF 1.25 RT / FPD 1.06 TTZ D 1.4 NF 1.60 TT / FPD 06 KP.51Z 3

4 Pulsation damper, FPD 10 KNF diaphragm pulsation dampers can effectively reduce the pulsation after the pump by up to 97%. Please note that the type of pulsation damper selected and the correct installation are essential in ensuring an optimal performance. FPD 10 ALLOWED PRESSURE 2 BAR Orifice for pump type FPD 10 KPZ D 2.8 NF 300 KP / FPD 10 KPZ D 3.4 NF 600 KP / FPD 10 KPZ D 3.8 NFB 100 KP / FPD 10 KTZ D 2.8 NF 300 KT / FPD 10 KTZ D 3.4 NF 600 KT / FPD 10 KTZ D 3.8 NFB 100 KT / FPD 10 TTZ D 2.8 NF 300 TT / FPD 10 TTZ D 3.4 NF 600 TT / FPD 10 TTZ D 3.8 NFB 100 TT / FPD 1.10 ALLOWED PRESSURE 6 BAR Orifice for pump type FPD 1.10 KPZ D 1.6 NF KP / FPD 1.10 KPZ D 2.0 NF KP / FPD 1.10 KPZ D 2.8 NF KP / FPD 1.10 KTZ D 1.6 NF KT / FPD 1.10 KTZ D 2.0 NF KT / FPD 1.10 KTZ D 2.8 NF KT / FPD 1.10 TTZ D 1.6 NF TT / FPD 1.10 TTZ D 2.0 NF TT / FPD 1.10 TTZ D 2.8 NF TT / FPD 10 KPZ 4

5 Pulsation damper, UFPD 06 KNF diaphragm pulsation dampers can effectively reduce the pulsation after the pump by up to 97%. Please note that the type of pulsation damper selected and the correct installation are essential in ensuring an optimal performance. UFPD 06 ALLOWED PRESSURE 2 BAR Orifice for pump type UFPD 06 KPZ D 0.7 NFB 5 KP / UFPD 06 KPZ D 1.0 NF 5 RP / UFPD 06 KPZ D 1.2 NF 10 / 25 KP / NFB 25 KP / UFPD 06 KPZ D 1.4 NF 30 / NF 60 KP / UFPD 06 KPZ D 1.8 UNF 100 KP / UFPD 06 KP.51Z D 1.4 NF 30 / NF 60 KP / UFPD 06 KTZ D 0.7 NFB 5 KT / UFPD 06 KTZ D 1.0 NF 5 RT / UFPD 06 KTZ D 1.2 NF 10 / 25 KT / NFB 25 KT / UFPD 06 KTZ D 1.4 NF 30 / NF 60 KT / UFPD 06 KTZ D 1.8 UNF 100 KT / UFPD 06 TTZ D 0.7 NFB 5 TT / UFPD 06 TTZ D 1.0 NF 5 RT / UFPD 06 TTZ D 1.2 NF 10 / 25 TT / NFB 25 TT / UFPD 06 TTZ D 1.4 NF 30 / NF 60 TT / UFPD 06 TTZ D 1.8 UNF 100 TT / FPD 06 KPZ UFPD 1.06 ALLOWED PRESSURE 6 BAR Orifice for pump type UFPD 1.06 KPZ D 0.7 NF 1.5 KP / UFPD 1.06 KPZ D 1.0 NF 1.11 KP / UFPD 1.06 KPZ D 1.2 UNF 1.25 RP / UFPD 1.06 KPZ D 1.4 UNF 1.60 KP / UFPD 1.06 KTZ D 0.7 NF 1.5 KT / NF 1.30 KT / UFPD 1.06 KTZ D 1.0 NF 1.11 KT / UFPD 1.06 KTZ D 1.2 UNF 1.25 RT / UFPD 1.06 KTZ D 1.4 UNF 1.60 KT / UFPD 1.06 TTZ D 0.7 NF 1.5 TT / NF 1.30 TT / UFPD 1.06 TTZ D 1.0 NF 1.11 TT / UFPD 1.06 TTZ D 1.2 UNF 1.25 RT / UFPD 1.06 TTZ D 1.4 UNF 1.60 TT / FPD 06 KP.51Z 5

6 Pulsation damper, UFPD 10 KNF diaphragm pulsation dampers can effectively reduce the pulsation after the pump by up to 97%. Please note that the type of pulsation damper selected and the correct installation are essential in ensuring an optimal performance. UFPD 10 ALLOWED PRESSURE 2 BAR Orifice for pump type UFPD 10 KPZ D 2.8 UNF 300 KP / UFPD 10 KPZ D 3.4 UNF 600 KP / UFPD 10 KPZ D 3.8 UNFB 100 KP / UFPD 10 KTZ D 2.8 UNF 300 KT / UFPD 10 KTZ D 3.4 UNF 600 KT / UFPD 10 KTZ D 3.8 UNFB 100 KT / UFPD 10 TTZ D 2.8 UNF 300 TT / UFPD 10 TTZ D 3.4 UNF 600 TT / UFPD 10 TTZ D 3.8 UNFB 100 TT / FPD 10 KPZ UFPD 1.10 ALLOWED PRESSURE 6 BAR Orifice for pump type UFPD 1.10 KPZ D 1.6 UNF KP / UFPD 1.10 KPZ D 2.0 UNF KP / UFPD 1.10 KPZ D 2.8 UNF KP / UFPD 1.10 KTZ D 1.6 UNF KT / UFPD 1.10 KTZ D 2.0 UNF KT / UFPD 1.10 KTZ D 2.8 UNF KT / UFPD 1.10 TTZ D 1.6 UNF TT / UFPD 1.10 TTZ D 2.0 UNF TT / UFPD 1.10 TTZ D 2.8 UNF TT /

7 Pressure control valves, FDV 30 KNF diaphragm pressure valves can be used to keep the system pressure constant. Either as pressure relief valve to reduce pressure peaks or to prevent the liquid from being sucked directly through the pump. This accessory can be used in combination with a KNF diaphragm pump or as an individual product. The FDV pressure valves are suitable for use with liquids and gases. The required pressure can be set by using a spindle/spring combination. This presses down on a diaphragm which is in contact with the liquid or gas. FDV 30 Set value FDV 30 KPZ 0.5 bar / FDV 30 KVZ 0.5 bar / FDV 30 KP.51Z 0.5 bar / FDV 30 TVZ 0.5 bar / FDV 30 KTZ 0.5 bar / FDV 30 TTZ 0.5 bar / FDV 30 KPZ FDV 31 FDV 31 KPZ with turning knob / FDV 31 KVZ with turning knob / FDV 31 TVZ with turning knob / FDV 31 KTZ with turning knob / FDV 31 TTZ with turning knob / FDV 1.30 Set value FDV 1.30 KPZ 3.0 bar / FDV 1.30 KVZ 3.0 bar / FDV 1.30 TVZ 3.0 bar / FDV 1.30 KTZ 3.0 bar / FDV 1.30 TTZ 3.0 bar / FDV 31 KPZ FDV 1.31 FDV 1.31 KPZ with turning knob / FDV 1.31 KVZ with turning knob / FDV 1.31 TVZ with turning knob / FDV 1.31 KTZ with turning knob / FDV 1.31 TTZ with turning knob /

8 Pressure control valves, FDV 300 KNF diaphragm pressure valves can be used to keep the system pressure constant. Either as pressure relief valve to reduce pressure peaks or to prevent the liquid from being sucked directly through the pump. This accessory can be used in combination with a KNF diaphragm pump or as an individual product. The FDV pressure valves are suitable for use with liquids and gases. The required pressure can be set by using a spindle/spring combination. This presses down on a diaphragm which is in contact with the liquid or gas. FDV 300 Set value FDV 300 KPZ 1.0 bar / FDV 300 KVZ 1.0 bar / FDV 300 TVZ 1.0 bar / FDV 300 KTZ 1.0 bar / FDV 300 TTZ 1.0 bar / FDV 301 FDV 301 KPZ with turning knob / FDV 301 KVZ with turning knob / FDV 301 TVZ with turning knob / FDV 301 KTZ with turning knob / FDV 301 TTZ with turning knob / FDV 300 KPZ FDV Set value FDV KPZ 3.0 bar / FDV KVZ 3.0 bar / FDV TVZ 3.0 bar / FDV KTZ 3.0 bar / FDV TTZ 3.0 bar / FDV 301 KPZ FDV FDV KPZ with turning knob / FDV KVZ with turning knob / FDV TVZ with turning knob / FDV KTZ with turning knob / FDV TTZ with turning knob /

9 Pressure control valves, UFDV 30 KNF diaphragm pressure valves can be used to keep the system pressure constant. Either as pressure relief valve to reduce pressure peaks or to prevent the liquid from being sucked directly through the pump.. This accessory can be used in combination with a KNF diaphragm pump or as an individual product. The FDV pressure valves are suitable for use with liquids and gases. The required pressure can be set by using a spindle/spring combination. This presses down on a diaphragm which is in contact with the liquid or gas. UFDV 30 Set value UFDV 30 KPZ 0.5 bar / UFDV 30 KVZ 0.5 bar / UFDV 30 KTZ 0.5 bar / UFDV 30 TVZ 0.5 bar / UFDV 30 TTZ 0.5 bar / UFDV 31 UFDV 31 KPZ with turning knob / UFDV 31 KVZ with turning knob / UFDV 31 KTZ with turning knob / UFDV 31 TVZ with turning knob / UFDV 31 TTZ with turning knob / UFDV 30 KPZ UFDV 1.30 Set value UFDV 1.30 KPZ 3.0 bar / UFDV 1.30 KVZ 3.0 bar / UFDV 1.30 KTZ 3.0 bar / UFDV 1.30 TVZ 3.0 bar / UFDV 1.30 TTZ 3.0 bar / UFDV 31 KPZ UFDV 1.31 UFDV 1.31 KPZ with turning knob / UFDV 1.31 KVZ with turning knob / UFDV 1.31 KTZ with turning knob / UFDV 1.31 TVZ with turning knob / UFDV 1.31 TTZ with turning knob /

10 Pressure control valves, UFDV 300 KNF diaphragm pressure valves can be used to keep the system pressure constant. Either as pressure relief valve to reduce pressure peaks or to prevent the liquid from being sucked directly through the pump. This accessory can be used in combination with a KNF diaphragm pump or as an individual product. The FDV pressure valves are suitable for use with liquids and gases. The required pressure can be set by using a spindle/spring combination. This presses down on a diaphragm which is in contact with the liquid or gas. FDV 300 Set value UFDV 300 KPZ 1.0 bar / UFDV 300 KVZ 1.0 bar / UFDV 300 KTZ 1.0 bar / UFDV 300 TVZ 1.0 bar / UFDV 300 TTZ 1.0 bar / FDV 301 UFDV 301 KPZ with turning knob / UFDV 301 KVZ with turning knob / UFDV 301 KTZ with turning knob / UFDV 301 TVZ with turning knob / UFDV 301 TTZ with turning knob / UFDV 301 KPZ FDV Set value UFDV KPZ 3.0 bar / UFDV KVZ 3.0 bar / UFDV KTZ 3.0 bar / UFDV TVZ 3.0 bar / UFDV TTZ 3.0 bar / FDV UFDV KPZ with turning knob / UFDV KVZ with turning knob / UFDV KTZ with turning knob / UFDV TVZ with turning knob / UFDV TTZ with turning knob /

11 Filters Construction Filtration is performed by a high-quality uniform mesh. Porosity The two mesh sizes of 70 µm for the PVDF version and 35 µm for the PEEK version offer optimised protection while allowing sufficient flow rates up to 600 ml/min. FS 25 Material* Mesh opening Max flow rate (liquids) Connectors FS 25 T PVDF 70 µm 250 ml/min for tubes ID 3.2 / 4 mm FS 25 X PEEK 35 µm 250 ml/min for tubes ID 3.2 / 4 mm * housing and filter mesh FS 60 Material* Mesh opening Max flow rate (liquids) Connectors FS 60 T PVDF 70 µm 600 ml/min UNF 1/ FS 60 X PEEK 35 µm 600 ml/min UNF 1/ * housing and filter mesh 11

12 Electrics and Electronics CONTROL BOARD FOR FEM 1.02/1.09 PUMP Function FE Z4 Transfer CONTROL BOARD FOR FEM 1.02/ PUMP Function FE Z5 Dispense

13 Electrics and Electronics CONTROL BOARD FOR FMM 80 PUMP Functions FE Z6 Push button for single stroke function (at frequency setting 0Hz) Continous frequency adjustment (0-20Hz) STARTER-KIT FOR FMM 80 PUMP Kit contains FSK 4 - Control unit - Electrical connection to pump - Power supply

14 Mounting options MOUNTING PLATE SET (SCREWS INCLUDED) For pump types FL 10, NF 5, NF 1.5, NF 10, FF 12, FF 20, NF 25, NF 1.25, NF 30, NF 1.30, NF MOUNTING SET FOR FL 10 For pump types FL ANTI-VIBRATION MOUNTING Connection Round buffer M

15 Hoses and hydraulic connectors HOSE-SET Material Dimension Length Connector(s) FEP AD 1/ mm UNF 1/4 (1x) HOSE-SET Material Dimension Length Connector(s) FEP AD 1/ mm UNF 1/4 (2x) HOSE-SETS Material Dimension Length Connector(s) FEP AD 1/ mm UNF 1/4 (1x) FEP AD 1/ mm UNF 1/4 (1x) HOSES Material Dimension Length Connector(s) PA12 blue ID 2.5 X 0.75 per meter no PA12 red ID 2X1 no PA white ID 4X1 no PE white ID 4X1 no PTFE transparent ID 4X1 no SI 55SH transparent ID 4X1 no ADAPTER Material FIT.-G A/I NPT1/8 UNF1/4-28 PTFE

DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301

DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301 DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV 1.300 / 1.301 FDV 31 KP Z A: Pump Accessories KP/KP.51 / KV / KT / TV / TT 30 / 1.30 / 31 / 1.31 / 300 / 1.300 / 301 / 1.301

More information

SM Models Manual Control

SM Models Manual Control SM Models Manual Control Practical Choice for Solenoid-driven Pumps Models for chemical injection, high-pressure boiler feed, and outgassing fluids. Temperatures ranges (ambient and transferring liquid)

More information

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified

DataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument

More information

SM Models Manual Control

SM Models Manual Control SM Models Manual Control Practical Choice for Solenoid-driven Pumps Models for chemical injection, high-pressure boiler feed, and outgassing fluids. Temperatures ranges (ambient and transferring liquid)

More information

MICRO DIAPHRAGM GAS PUMPS

MICRO DIAPHRAGM GAS PUMPS MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP83KNE NMP85KPDC NMP85.1.2KPDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge, moves

More information

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 010 N 89 KNDC N 811 KNE N 814 KNE Concept The mini diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,

More information

MINI DIAPHRAGM VACUUM PUMPS

MINI DIAPHRAGM VACUUM PUMPS MINI DIAPHRAGM VACUUM PUMPS DATA SHEET E 024 N 815 KNE N 828 KNDC-B N 838 KNDC Concept The mini diaphragm gas sampling pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

Model 2851 CONSTANT FLOW REGULATOR

Model 2851 CONSTANT FLOW REGULATOR CONSTANT FLOW REGULATOR Model 2851 The model 2851 constant flow regulator is designed to provide constant flow of liquids or gases regardless of pressure variations. It is intended for low liquid flows

More information

Pressure Relief Valve DHV 718

Pressure Relief Valve DHV 718 Pressure Relief Valve DHV 718 Nominal size DN 8 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 0.5 to 10 bar diaphragm controlled pressure relief valve simple design,

More information

SP/ST/SA Models Pulse-input and Analog-input Control

SP/ST/SA Models Pulse-input and Analog-input Control SP/ST/SA Pulse-input and -input Control Smart and Intuitive Operation Simple key functions and user interface for ease of operation. Range can be set between 1 and 3 strokes per minute in 1-stroke units.

More information

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL

Beamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL Beamex PG PRESSURE GENERATORS 97 Beamex PGM PGV PGC PGHH PGPH PGL Beamex PG pressure generators are portable hand-operated pressure generators and ultimate field calibration pumps 98 Calibration pumps

More information

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE MAKING MODERN LIVING POSSIBLE Data sheet Water valve Type WVO Water valve type WVO is used for regulating the flow of water in refrigeration plant with water-cooled condensers. The water valve gives modulating

More information

MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET NF 100/1.100 NF 100 / 1.100

MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET NF 100/1.100 NF 100 / 1.100 MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET /1.100 / 1.100 KP.51 DC NF 1.100 KPE KP.27 AA Concept KNF diaphragm liquid pumps are based on the principle of the oscillating displacement pump which is remarkably

More information

Filtration FILTRATION PRODUCT TIPS

Filtration FILTRATION PRODUCT TIPS Filtration 195 18 Proved and tested, durable, optimally resistant against acids, caustic solutions and other aggressive chemicals: our solutions for efficient and safe filtration. PRODUCT TIPS BOLA Filtration

More information

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES PRESSURE REGULATORS ALL MEDICAL GASES In this section we propose our pressure regulators (FM series, MU and MERCURY ) and our Rs flowmeters for applications other than oxygen therapy (presented in the

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external

More information

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860

Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 PROCESS Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 Single & Twin-Head Designs OEM Installation Models UN860FTI EX UN726.3STI EX UN726.3FTI

More information

Electronic relative and differential pressure switch type 616

Electronic relative and differential pressure switch type 616 Electronic relative and differential pressure switch type 616 Pressure range 0... 0.1 25 bar The switching points of the pressure switch type 616 can be potentiometer adjusted by the customer, or set in

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 143 N 143 SP.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information

Pilot valves for pilot operated servo valves

Pilot valves for pilot operated servo valves Data sheet Pilot valves for pilot operated servo valves The range of pilot valves consists of: Constant-pressure pilot valve, type CVP (LP) and CVP (HP) Differential-pressure pilot valve, type CVPP (LP)

More information

Willkommen. Welcome to KNF - presentation

Willkommen. Welcome to KNF - presentation Willkommen Welcome to KNF - presentation KNF modular system, way to Project pump heads available in: - aluminium - plastics (PPS, Peek ) - stainless steel - PTFE diaphragms und valves available in: - Neopren

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

Pressure transmitters EMP 2

Pressure transmitters EMP 2 Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,

More information

SIMDOS 02 DIAPHRAGM METERING PUMP

SIMDOS 02 DIAPHRAGM METERING PUMP LAB FEM1.02.18 OPERATING INSTRUCTIONS SIMDOS 02 DIAPHRAGM METERING PUMP Before operating the pump and the accessories, please read the operating instructions and pay attention to the safety precautions.

More information

Schroeder Check Test Point System

Schroeder Check Test Point System Perforated polyamide / kevlar hose, 2 mm ID, 5 mm OD, plastic dust cap. L in (mm) P (max) psi (bar) 6 (150) 10,000 (680) 12 (300) 10,000 (680) 24 (610) 10,000 (680) 36 (915) 10,000 (680) 48 (1220) 10,000

More information

SIMDOS 10 DIAPHRAGM METERING PUMP

SIMDOS 10 DIAPHRAGM METERING PUMP LAB FEM1.10.18 2 OPERATING INSTRUCTIONS SIMDOS 10 DIAPHRAGM METERING PUMP Before operating the pump and the accessories, please read the operating instructions and pay attention to the safety precautions.

More information

Best Practices for Installation of Gaseous Sample Pumps

Best Practices for Installation of Gaseous Sample Pumps Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure

More information

B74G - EXCELON Modular System General purpose filter/regulator

B74G - EXCELON Modular System General purpose filter/regulator > Port size: /8... / (ISO G/PTF) > Excelon design allows in-line installation or modular installation with other Excelon products > Push to lock adjusting knob with optional tamper resistant accessory

More information

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar 692 Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle 0 0.1 25 bar E Technical overview The differential pressure transmitter of type series 692 with

More information

PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES

PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES 1 3 1 - ALPINOX: oxygen Regulator - Medical oxygen regulator with flowmeter. - Medical oxygen regulator with flowmeter and Quick

More information

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

TECHNOLOGIES. M Series. Positive return metering pumps [API675] M Series Positive return metering pumps [API675] Hydraulic double diaphragm metering pump in AISI 316L stainless steel A line of plunger and hydraulic double diaphragm metering pumps designed according

More information

Operating Instructions

Operating Instructions Operating Instructions Multifunction Valve Contents Page Safety Instructions... 2 Unpacking... 2 Introduction... 2 Dimensions... 4 Installation...2-3 Description of Controls & Operation... 3 Page Helpful

More information

RK LEL Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual 30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings

More information

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps

ROYTRONIC EXCEL TM Series AD Electronic Metering Pumps 0.20 5.1 ROYTRONIC EXCEL TM AD Electronic Metering Pumps LMI ROYTRONIC EXCEL AD pumps achieve a new level of innovation in solenoid-driven metering pump technology. Offering a robust design, micropressor

More information

Accessories. Valves. Adjustable Pressure Relief Valves

Accessories. Valves. Adjustable Pressure Relief Valves Valves djustable Pressure Relief Valves djustable pressure relief valves allow for variable operating pressures anywhere between PSI ( bar). In order to prevent overloading of the motor, however, the maximum

More information

High precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment

High precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment Fluid dose dispensing valve High precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment Provides the high productivity, stability, reliability,

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

3/4 MPT w/ MHT Flush & Cap (80 psi) (A2)

3/4 MPT w/ MHT Flush & Cap (80 psi) (A2) 4E PLASTIC FILTERS Debris Basin Typical Filter Components Shown 3/4 MPT w/ MHT Flush & Cap (80 psi) (A2) Note: All Plastic Filter models available drilled and tapped for 1/8 schrader valve. Contact customer

More information

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version 2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for

More information

Hip Air Operated Valves

Hip Air Operated Valves Hydraulic & Offshore Supplies Hip Air Operated s YOUR GATEWAY TO GLOBAL SUPPLY HOSE ASSEMBLIES PRESSURE TESTING WALFORM EQUIPMENT PACKAGES FLANGES PIPE & TUBE Air Operated s High Pressure Equipment Company

More information

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order Process Pump /5 Series Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted areas.

More information

SIMDOS 02 DIAPHRAGM METERING PUMP

SIMDOS 02 DIAPHRAGM METERING PUMP LAB FEM02.18 OPERATING INSTRUCTIONS SIMDOS 02 DIAPHRAGM METERING PUMP Before operating the pump and the accessories, please read the operating instructions and pay attention to the safety precautions.

More information

Precision Pressure Regulators

Precision Pressure Regulators hapter - Pressure Regulators Pressure range onnection thread Device Page 3 mm, high precision 0.0 2 / 8 bar G 1 8 RI.02 highly sensitive, max. 3 bar supply pressure 0.002 0.12 / 31 bar ¼"NPT R40.03 without

More information

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)

Features. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing) 1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings

More information

UsER manual for Watersens ph -REDOX

UsER manual for Watersens ph -REDOX UsER manual for Watersens -REDOX Cl 8 1 2 6 3 3 7 7 4 4 4 4 Parts List 1 Redox Probe 1 x 2 PH Probe 1 x 5 Tube Weight 2 x 6 Connection Valve 1 x chlorine 3 Chlorine and Pumps 2 x 7 Dosing Valve 2 x 5 5

More information

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids HELYON 5 Chemin du Jubin 69570 DARDILLY Tél. +33 (0)4 72 52 16 70 - Fax +33 (0)4 72 52 16 71 R300 Brass high pressure regulator, for compressed air, gas and liquids FEATURES Pressure regulator for inlet

More information

OXYGEN THERAPY FLOWMETERS, REUSABLE AND SINGLE-PATIENT HUMIDIFIERS, PRESSURE REGULATORS, FLOW SELECTORS

OXYGEN THERAPY FLOWMETERS, REUSABLE AND SINGLE-PATIENT HUMIDIFIERS, PRESSURE REGULATORS, FLOW SELECTORS OXYGEN THERAPY The line of oxygen therapy devices includes variable area flowmeters, calibrated holes dial flowmeters, pressure reducers with their cylinder connections, humidifiers, flow selectors and

More information

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology V-Major, V-Compact Reciprocating Compressors Intelligent Air Technology & Significant Energy Savings with Lower Running Costs Efficient. LOW POWER CONSUMPTION 75% of the running cost of an air compressor

More information

Pressure switches for air and water CS

Pressure switches for air and water CS Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the

More information

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119 Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

WaterSource Heat Pump Hose Kit Performance Specification-Summary

WaterSource Heat Pump Hose Kit Performance Specification-Summary WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo

More information

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司

X-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司 X-Flow Mass Flow Controller 2 Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow, a new easy to use general purpose mass flow controller for your instrument, lab, or

More information

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 9 N 9 FTE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #: ID-Cube Installation and Operations Manual For ID-Cube Source and Power Supply Revision 2 Document #: 7.1.002 IonSense Inc. 999 Broadway Suite 404 Saugus, MA 01906 Copyright 2014 by IonSense Inc. All rights

More information

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve) Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve) When working pressure change, inside diaphragm and needle valve operates in order to always keeping a fixed flow rate for exact

More information

Hydraulic Accumulators with Back-Up Nitrogen Bottles

Hydraulic Accumulators with Back-Up Nitrogen Bottles Hydraulic Accumulators with Back-Up Nitrogen Bottles 1. GENERAL To complete the accumulator range, HYDAC provides a variety of useful accessory products. They guarantee correct installation and optimum

More information

Description Pressure range Connection thread Device Page bar

Description Pressure range Connection thread Device Page bar Pressure Regulator Pressure range onnection thread Device Page bar factory-set pressure artridge regulator 2 / 3 / 4 / 6 artridge 233.02 without exhaust 7 x 25 2 / 3 / /0 G¼ia R3.03 for liquids 34 x 52

More information

215 Liquid Handler Up-Grade Manual

215 Liquid Handler Up-Grade Manual BRUKER NMR 220 25 Liquid Handler Up-Grade Manual For Up-Grade to Run with XWINNMR Vers.. Manual # H977 The kit will include: H9770 BEST NMR Up-Grade Kit to No. Article Bruker # Comment 500mm Capillary

More information

ELADOS EDP L Diaphragm Metering Pump Type

ELADOS EDP L Diaphragm Metering Pump Type ELADOS EDP L Diaphragm Metering Pump Type 04800-06700 Motor-driven diaphragm pump with integrated frequency converter High reserves due to a powerful asynchronous motor High flexibility due to variably

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

MICRO DIAPHRAGM GAS PUMPS

MICRO DIAPHRAGM GAS PUMPS MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP 83 KNE NMP 85 KNDC NMP 85.1.2 KNDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,

More information

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Description Supply pressure Pressure range Connection Device Page max. bar bar thread Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4

More information

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits

1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits /-Way Angle-Seat Valve Type 000 to - NPT; 0 to 30 Advantages / Benefits Spring return closed or open, double-acting Materials: bronze, stainless steel High flow rate Self-adjusting packing glands with

More information

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800 KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

SuperFinish 27. Available versions. Accessories. SuperFinish 27 Spraypack. Basic unit. Tip extensions / pole guns. Suction systems.

SuperFinish 27. Available versions. Accessories. SuperFinish 27 Spraypack. Basic unit. Tip extensions / pole guns. Suction systems. Available versions Spraypack Basic unit 0341 051 basic unit on trolley including pressure gauge system + QuickClean suction + 15 m high pressure hose + Airless gun G 12 + Wagner Tip holder with Airless

More information

Powers Controls D Day-Night Thermostats

Powers Controls D Day-Night Thermostats Powers Controls D Day-Night Thermostats Technical Instructions Document No. 155-073P25 TH 832-2 Description The D Day-Night or Two Temperature Thermostat is available as a room-type instrument. It is essentially

More information

Relative and differential pressure transmitter type 692

Relative and differential pressure transmitter type 692 Relative and differential pressure transmitter type 692 Pressure range 0... 0.1 25 bar Type 692 pressure transmitters have a unique, well proven ceramic technolgy. There are variety of pressure and electrical

More information

LPK1230 Hydraulic Crimping Tool 12 ton

LPK1230 Hydraulic Crimping Tool 12 ton SPECIFICATIONS AND PARTS LPK1230 Hydraulic Crimping Tool 12 ton Serial Code FYB Read and understand all of the instructions and safety information in this manual before operating or servicing this tool.

More information

WARNING. Work drop prevention check valves FPV series. Vacuum accessories. Safety handling of workpiece with several pads

WARNING. Work drop prevention check valves FPV series. Vacuum accessories. Safety handling of workpiece with several pads Work drop prevention check valves series Safety handling of workpiece with several pads Enable using one CONVUM ejector and several pads, in applications where some of the suction pads may not be in contact

More information

SPD310/SPD360 Air Differential

SPD310/SPD360 Air Differential SPD310/SPD360 Air Differential Pressure SPD310 / SPD360 SPD310 / SPD360 differential pressure transmitters are intended for use in air handling systems for the monitoring of air ducts, filters and fans.

More information

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17

Gas Filters DN15 DN300. delta-elektrogas.com EE151 03/17 FG Gas Filters DN15 DN300 delta-elektrogas.com EE151 03/17 FG Gas Filters Contents Description.. 2 Features.. 2 Functioning and application. 3 Technical specifications 4 Gas flow chart (pressure drop)

More information

LRS(H)4 Pressure-Reducing Regulator User Manual

LRS(H)4 Pressure-Reducing Regulator User Manual LRS(H)4 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be considered

More information

1200 Series Pressure Regulators

1200 Series Pressure Regulators SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of

More information

TF- & DM-Series. Turbineflowmeter

TF- & DM-Series. Turbineflowmeter Turbineflowmeter .. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation

More information

FLOWMETER UNITS FLOWMETER DEVICES, BY-PASS SYSTEMS

FLOWMETER UNITS FLOWMETER DEVICES, BY-PASS SYSTEMS FLOWMETER UNITS The range of anesthesia flowmeter units series FM, SF and RM, available in different configurations, makes it possible to offer many options to meet various requirements in the operating

More information

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology

Airless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology Airless-Spraying Equipment SuperFinish31 Fully equipped More power Innovative QLS technology New technology, fully equipped with even more power. This is the new SuperFinish 31 Airless spraying equipment,

More information

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.

BSP Pressure Sensor Balluff GmbH, BA Marco Zorcic. 1 2 Standard Pressure Sensor with display Overview Pressure Range Relative nominal Overload Burst Permitted negative -1..2 bar 2 bar 4 bar 10 bar -1..10 bar 10 bar 20 bar 35 bar 0..2 bar 2 bar 4 bar 10

More information

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products

More information

Additel 780 Series Pressure Controller

Additel 780 Series Pressure Controller Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale

More information

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at

More information

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder

More information

Low Pressure Diaphragm Sealed Pressure Gauges (571P & 573P Sereies)

Low Pressure Diaphragm Sealed Pressure Gauges (571P & 573P Sereies) Applications Low pressure measuring Specially designed for chemical, petrochemical, paper and food industry All gaseous and liquid media Corrode, Suspended solid, Viscous or Frozen medium Shock & vibration

More information

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical

More information

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual 30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

Pocket Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Pocket Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX: Pumps models are ideal for low flow, low pressure metering applications. The pump is constructed entirely of plastic and utilizes GRI s time-proven bellows technology to provide an accurate chemically-resistant

More information

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25

More information

Pressure relief valve DHV 718

Pressure relief valve DHV 718 Pressure relief valve DHV 78 Benefits diaphragm controlled pressure relief valve with piston guidance simple design, reliable function particularly suitable for oscillating pumps constant, frictionless

More information

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 / Air Line Kit AL - M1202 / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 002 1 Thank you for purchasing the Air Line Kit " AL - M1202 ". This Air Line Kit is designed to adjust the air supply

More information

Installation Instructions

Installation Instructions Installation Instructions S65-135 (Circular) S65-136 (Semi-Circular) Air Valve Retrofit For Non-Sectional Classic Washfountain Table of Contents.......................2-6 Metering Air Valve Parts List....................6

More information

INDUSTRIAL PNEUMATICS - air treatment units. FIL filter

INDUSTRIAL PNEUMATICS - air treatment units. FIL filter Due to its metal construction, the entire range of NEW DEAL elements is resistant to heavy duty working conditions. Designed for high pressure application (up to 18 bar). FIL filter Degree of filtration:

More information

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized

More information

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized

More information

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 922 N 922 FTE Concept The diaphragm pumps from KNF are based on a simple principle - an elastic diaphragm, ixed on its edge, moves up and

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 16 N 35 ANE with IP 2 motor Concept The diaphragm pumps from KNF are based on a simple principal - an elastic diaphragm, ixed on its edge, moves up and

More information