LIQUID PUMPS ACCESSORIES OVERVIEW
|
|
- Howard Webster
- 5 years ago
- Views:
Transcription
1 LIQUID PUMPS ACCESSORIES OVERVIEW
2 INDEX Pulsation damper, FPD 06 3 Pulsation damper, FPD 10 4 Pulsation damper, UFPD 06 5 Pulsation damper, UFPD 10 6 Pressure control valves, FDV 30 7 Pressure control valves, FDV Pressure control valves, UFDV 30 9 Pressure control valves, UFDV Filters 11 Electrics and Electronics 12 Mounting options 14 Hoses and hydraulic connectors 15 2
3 Pulsation damper, FPD 06 KNF diaphragm pulsation dampers can effectively reduce the pulsation after the pump by up to 97%. Please note that the type of pulsation damper selected and the correct installation are essential in ensuring an optimal performance. FPD 06 ALLOWED PRESSURE 2 BAR Orifice for pump type FPD 06 KPZ D 0.7 NFB 5 KP / FPD 06 KPZ D 1.0 NF 5 RP / FPD 06 KPZ D 1.2 NF 10 / 25 KP / NFB 25 KP / FPD 06 KPZ D 1.4 NF 30 / NF 60 KP / FPD 06 KPZ D 1.8 NF 100 KP / FPD 06 KP.51Z D 1.4 NF 30 / NF 60 KP / FPD 06 KTZ D 0.7 NFB 5 KT / FPD 06 KTZ D 1.0 NF 5 RT / FPD 06 KTZ D 1.2 NF 10 / 25 KT / NFB 25 KT / FPD 06 KTZ D 1.4 NF 30 / NF 60 KT / FPD 06 KTZ D 1.8 NF 100 KT / FPD 06 TTZ D 0.7 NFB 5 TT / FPD 06 TTZ D 1.0 NF 5 RT / FPD 06 TTZ D 1.2 NF 10 / 25 TT / NFB 25 TT / FPD 06 TTZ D 1.4 NF 30 / NF 60 TT / FPD 06 TTZ D 1.8 NF 100 TT / FPD 06 KPZ FPD 1.06 ALLOWED PRESSURE 6 BAR Orifice for pump type FPD 1.06 KPZ D 0.7 NF 1.5 KP / FPD 1.06 KPZ D 1.0 NF 1.11 KP / FPD 1.06 KPZ D 1.2 NF 1.25 RP / FPD 1.06 KPZ D 1.4 NF 1.60 KP / FPD 1.06 KTZ D 0.7 NF 1.5 KT / NF 1.30 KT / FPD 1.06 KTZ D 1.0 NF 1.11 KT / FPD 1.06 KTZ D 1.2 NF 1.25 RT / FPD 1.06 KTZ D 1.4 NF 1.60 KT / FPD 1.06 TTZ D 0.7 NF 1.5TT / NF 1.30 TT / FPD 1.06 TTZ D 1.0 NF 1.11 TT / FPD 1.06 TTZ D 1.2 NF 1.25 RT / FPD 1.06 TTZ D 1.4 NF 1.60 TT / FPD 06 KP.51Z 3
4 Pulsation damper, FPD 10 KNF diaphragm pulsation dampers can effectively reduce the pulsation after the pump by up to 97%. Please note that the type of pulsation damper selected and the correct installation are essential in ensuring an optimal performance. FPD 10 ALLOWED PRESSURE 2 BAR Orifice for pump type FPD 10 KPZ D 2.8 NF 300 KP / FPD 10 KPZ D 3.4 NF 600 KP / FPD 10 KPZ D 3.8 NFB 100 KP / FPD 10 KTZ D 2.8 NF 300 KT / FPD 10 KTZ D 3.4 NF 600 KT / FPD 10 KTZ D 3.8 NFB 100 KT / FPD 10 TTZ D 2.8 NF 300 TT / FPD 10 TTZ D 3.4 NF 600 TT / FPD 10 TTZ D 3.8 NFB 100 TT / FPD 1.10 ALLOWED PRESSURE 6 BAR Orifice for pump type FPD 1.10 KPZ D 1.6 NF KP / FPD 1.10 KPZ D 2.0 NF KP / FPD 1.10 KPZ D 2.8 NF KP / FPD 1.10 KTZ D 1.6 NF KT / FPD 1.10 KTZ D 2.0 NF KT / FPD 1.10 KTZ D 2.8 NF KT / FPD 1.10 TTZ D 1.6 NF TT / FPD 1.10 TTZ D 2.0 NF TT / FPD 1.10 TTZ D 2.8 NF TT / FPD 10 KPZ 4
5 Pulsation damper, UFPD 06 KNF diaphragm pulsation dampers can effectively reduce the pulsation after the pump by up to 97%. Please note that the type of pulsation damper selected and the correct installation are essential in ensuring an optimal performance. UFPD 06 ALLOWED PRESSURE 2 BAR Orifice for pump type UFPD 06 KPZ D 0.7 NFB 5 KP / UFPD 06 KPZ D 1.0 NF 5 RP / UFPD 06 KPZ D 1.2 NF 10 / 25 KP / NFB 25 KP / UFPD 06 KPZ D 1.4 NF 30 / NF 60 KP / UFPD 06 KPZ D 1.8 UNF 100 KP / UFPD 06 KP.51Z D 1.4 NF 30 / NF 60 KP / UFPD 06 KTZ D 0.7 NFB 5 KT / UFPD 06 KTZ D 1.0 NF 5 RT / UFPD 06 KTZ D 1.2 NF 10 / 25 KT / NFB 25 KT / UFPD 06 KTZ D 1.4 NF 30 / NF 60 KT / UFPD 06 KTZ D 1.8 UNF 100 KT / UFPD 06 TTZ D 0.7 NFB 5 TT / UFPD 06 TTZ D 1.0 NF 5 RT / UFPD 06 TTZ D 1.2 NF 10 / 25 TT / NFB 25 TT / UFPD 06 TTZ D 1.4 NF 30 / NF 60 TT / UFPD 06 TTZ D 1.8 UNF 100 TT / FPD 06 KPZ UFPD 1.06 ALLOWED PRESSURE 6 BAR Orifice for pump type UFPD 1.06 KPZ D 0.7 NF 1.5 KP / UFPD 1.06 KPZ D 1.0 NF 1.11 KP / UFPD 1.06 KPZ D 1.2 UNF 1.25 RP / UFPD 1.06 KPZ D 1.4 UNF 1.60 KP / UFPD 1.06 KTZ D 0.7 NF 1.5 KT / NF 1.30 KT / UFPD 1.06 KTZ D 1.0 NF 1.11 KT / UFPD 1.06 KTZ D 1.2 UNF 1.25 RT / UFPD 1.06 KTZ D 1.4 UNF 1.60 KT / UFPD 1.06 TTZ D 0.7 NF 1.5 TT / NF 1.30 TT / UFPD 1.06 TTZ D 1.0 NF 1.11 TT / UFPD 1.06 TTZ D 1.2 UNF 1.25 RT / UFPD 1.06 TTZ D 1.4 UNF 1.60 TT / FPD 06 KP.51Z 5
6 Pulsation damper, UFPD 10 KNF diaphragm pulsation dampers can effectively reduce the pulsation after the pump by up to 97%. Please note that the type of pulsation damper selected and the correct installation are essential in ensuring an optimal performance. UFPD 10 ALLOWED PRESSURE 2 BAR Orifice for pump type UFPD 10 KPZ D 2.8 UNF 300 KP / UFPD 10 KPZ D 3.4 UNF 600 KP / UFPD 10 KPZ D 3.8 UNFB 100 KP / UFPD 10 KTZ D 2.8 UNF 300 KT / UFPD 10 KTZ D 3.4 UNF 600 KT / UFPD 10 KTZ D 3.8 UNFB 100 KT / UFPD 10 TTZ D 2.8 UNF 300 TT / UFPD 10 TTZ D 3.4 UNF 600 TT / UFPD 10 TTZ D 3.8 UNFB 100 TT / FPD 10 KPZ UFPD 1.10 ALLOWED PRESSURE 6 BAR Orifice for pump type UFPD 1.10 KPZ D 1.6 UNF KP / UFPD 1.10 KPZ D 2.0 UNF KP / UFPD 1.10 KPZ D 2.8 UNF KP / UFPD 1.10 KTZ D 1.6 UNF KT / UFPD 1.10 KTZ D 2.0 UNF KT / UFPD 1.10 KTZ D 2.8 UNF KT / UFPD 1.10 TTZ D 1.6 UNF TT / UFPD 1.10 TTZ D 2.0 UNF TT / UFPD 1.10 TTZ D 2.8 UNF TT /
7 Pressure control valves, FDV 30 KNF diaphragm pressure valves can be used to keep the system pressure constant. Either as pressure relief valve to reduce pressure peaks or to prevent the liquid from being sucked directly through the pump. This accessory can be used in combination with a KNF diaphragm pump or as an individual product. The FDV pressure valves are suitable for use with liquids and gases. The required pressure can be set by using a spindle/spring combination. This presses down on a diaphragm which is in contact with the liquid or gas. FDV 30 Set value FDV 30 KPZ 0.5 bar / FDV 30 KVZ 0.5 bar / FDV 30 KP.51Z 0.5 bar / FDV 30 TVZ 0.5 bar / FDV 30 KTZ 0.5 bar / FDV 30 TTZ 0.5 bar / FDV 30 KPZ FDV 31 FDV 31 KPZ with turning knob / FDV 31 KVZ with turning knob / FDV 31 TVZ with turning knob / FDV 31 KTZ with turning knob / FDV 31 TTZ with turning knob / FDV 1.30 Set value FDV 1.30 KPZ 3.0 bar / FDV 1.30 KVZ 3.0 bar / FDV 1.30 TVZ 3.0 bar / FDV 1.30 KTZ 3.0 bar / FDV 1.30 TTZ 3.0 bar / FDV 31 KPZ FDV 1.31 FDV 1.31 KPZ with turning knob / FDV 1.31 KVZ with turning knob / FDV 1.31 TVZ with turning knob / FDV 1.31 KTZ with turning knob / FDV 1.31 TTZ with turning knob /
8 Pressure control valves, FDV 300 KNF diaphragm pressure valves can be used to keep the system pressure constant. Either as pressure relief valve to reduce pressure peaks or to prevent the liquid from being sucked directly through the pump. This accessory can be used in combination with a KNF diaphragm pump or as an individual product. The FDV pressure valves are suitable for use with liquids and gases. The required pressure can be set by using a spindle/spring combination. This presses down on a diaphragm which is in contact with the liquid or gas. FDV 300 Set value FDV 300 KPZ 1.0 bar / FDV 300 KVZ 1.0 bar / FDV 300 TVZ 1.0 bar / FDV 300 KTZ 1.0 bar / FDV 300 TTZ 1.0 bar / FDV 301 FDV 301 KPZ with turning knob / FDV 301 KVZ with turning knob / FDV 301 TVZ with turning knob / FDV 301 KTZ with turning knob / FDV 301 TTZ with turning knob / FDV 300 KPZ FDV Set value FDV KPZ 3.0 bar / FDV KVZ 3.0 bar / FDV TVZ 3.0 bar / FDV KTZ 3.0 bar / FDV TTZ 3.0 bar / FDV 301 KPZ FDV FDV KPZ with turning knob / FDV KVZ with turning knob / FDV TVZ with turning knob / FDV KTZ with turning knob / FDV TTZ with turning knob /
9 Pressure control valves, UFDV 30 KNF diaphragm pressure valves can be used to keep the system pressure constant. Either as pressure relief valve to reduce pressure peaks or to prevent the liquid from being sucked directly through the pump.. This accessory can be used in combination with a KNF diaphragm pump or as an individual product. The FDV pressure valves are suitable for use with liquids and gases. The required pressure can be set by using a spindle/spring combination. This presses down on a diaphragm which is in contact with the liquid or gas. UFDV 30 Set value UFDV 30 KPZ 0.5 bar / UFDV 30 KVZ 0.5 bar / UFDV 30 KTZ 0.5 bar / UFDV 30 TVZ 0.5 bar / UFDV 30 TTZ 0.5 bar / UFDV 31 UFDV 31 KPZ with turning knob / UFDV 31 KVZ with turning knob / UFDV 31 KTZ with turning knob / UFDV 31 TVZ with turning knob / UFDV 31 TTZ with turning knob / UFDV 30 KPZ UFDV 1.30 Set value UFDV 1.30 KPZ 3.0 bar / UFDV 1.30 KVZ 3.0 bar / UFDV 1.30 KTZ 3.0 bar / UFDV 1.30 TVZ 3.0 bar / UFDV 1.30 TTZ 3.0 bar / UFDV 31 KPZ UFDV 1.31 UFDV 1.31 KPZ with turning knob / UFDV 1.31 KVZ with turning knob / UFDV 1.31 KTZ with turning knob / UFDV 1.31 TVZ with turning knob / UFDV 1.31 TTZ with turning knob /
10 Pressure control valves, UFDV 300 KNF diaphragm pressure valves can be used to keep the system pressure constant. Either as pressure relief valve to reduce pressure peaks or to prevent the liquid from being sucked directly through the pump. This accessory can be used in combination with a KNF diaphragm pump or as an individual product. The FDV pressure valves are suitable for use with liquids and gases. The required pressure can be set by using a spindle/spring combination. This presses down on a diaphragm which is in contact with the liquid or gas. FDV 300 Set value UFDV 300 KPZ 1.0 bar / UFDV 300 KVZ 1.0 bar / UFDV 300 KTZ 1.0 bar / UFDV 300 TVZ 1.0 bar / UFDV 300 TTZ 1.0 bar / FDV 301 UFDV 301 KPZ with turning knob / UFDV 301 KVZ with turning knob / UFDV 301 KTZ with turning knob / UFDV 301 TVZ with turning knob / UFDV 301 TTZ with turning knob / UFDV 301 KPZ FDV Set value UFDV KPZ 3.0 bar / UFDV KVZ 3.0 bar / UFDV KTZ 3.0 bar / UFDV TVZ 3.0 bar / UFDV TTZ 3.0 bar / FDV UFDV KPZ with turning knob / UFDV KVZ with turning knob / UFDV KTZ with turning knob / UFDV TVZ with turning knob / UFDV TTZ with turning knob /
11 Filters Construction Filtration is performed by a high-quality uniform mesh. Porosity The two mesh sizes of 70 µm for the PVDF version and 35 µm for the PEEK version offer optimised protection while allowing sufficient flow rates up to 600 ml/min. FS 25 Material* Mesh opening Max flow rate (liquids) Connectors FS 25 T PVDF 70 µm 250 ml/min for tubes ID 3.2 / 4 mm FS 25 X PEEK 35 µm 250 ml/min for tubes ID 3.2 / 4 mm * housing and filter mesh FS 60 Material* Mesh opening Max flow rate (liquids) Connectors FS 60 T PVDF 70 µm 600 ml/min UNF 1/ FS 60 X PEEK 35 µm 600 ml/min UNF 1/ * housing and filter mesh 11
12 Electrics and Electronics CONTROL BOARD FOR FEM 1.02/1.09 PUMP Function FE Z4 Transfer CONTROL BOARD FOR FEM 1.02/ PUMP Function FE Z5 Dispense
13 Electrics and Electronics CONTROL BOARD FOR FMM 80 PUMP Functions FE Z6 Push button for single stroke function (at frequency setting 0Hz) Continous frequency adjustment (0-20Hz) STARTER-KIT FOR FMM 80 PUMP Kit contains FSK 4 - Control unit - Electrical connection to pump - Power supply
14 Mounting options MOUNTING PLATE SET (SCREWS INCLUDED) For pump types FL 10, NF 5, NF 1.5, NF 10, FF 12, FF 20, NF 25, NF 1.25, NF 30, NF 1.30, NF MOUNTING SET FOR FL 10 For pump types FL ANTI-VIBRATION MOUNTING Connection Round buffer M
15 Hoses and hydraulic connectors HOSE-SET Material Dimension Length Connector(s) FEP AD 1/ mm UNF 1/4 (1x) HOSE-SET Material Dimension Length Connector(s) FEP AD 1/ mm UNF 1/4 (2x) HOSE-SETS Material Dimension Length Connector(s) FEP AD 1/ mm UNF 1/4 (1x) FEP AD 1/ mm UNF 1/4 (1x) HOSES Material Dimension Length Connector(s) PA12 blue ID 2.5 X 0.75 per meter no PA12 red ID 2X1 no PA white ID 4X1 no PE white ID 4X1 no PTFE transparent ID 4X1 no SI 55SH transparent ID 4X1 no ADAPTER Material FIT.-G A/I NPT1/8 UNF1/4-28 PTFE
DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV / 1.301
DIAPHRAGM PRESSURE CONTROL VALVE FDV 30 / 31, FDV 1.30 / 1.30 FDV 300 / 301, FDV 1.300 / 1.301 FDV 31 KP Z A: Pump Accessories KP/KP.51 / KV / KT / TV / TT 30 / 1.30 / 31 / 1.31 / 300 / 1.300 / 301 / 1.301
More informationSM Models Manual Control
SM Models Manual Control Practical Choice for Solenoid-driven Pumps Models for chemical injection, high-pressure boiler feed, and outgassing fluids. Temperatures ranges (ambient and transferring liquid)
More informationDataSheet. Series AA Electronic Metering Pumps. Configuration Data. Dimensions. Specifications. Model AA HI. ISO 9001 Certified
DataSheet Series AA Electronic Metering Pumps Configuration Data Model AA 9 4 1-358HI Control Code 1 --- Manual Control: Speed (stroking frequency) and stroke length manually adjustable. 7 --- Instrument
More informationSM Models Manual Control
SM Models Manual Control Practical Choice for Solenoid-driven Pumps Models for chemical injection, high-pressure boiler feed, and outgassing fluids. Temperatures ranges (ambient and transferring liquid)
More informationMICRO DIAPHRAGM GAS PUMPS
MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP83KNE NMP85KPDC NMP85.1.2KPDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge, moves
More informationMINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS
MINI DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 010 N 89 KNDC N 811 KNE N 814 KNE Concept The mini diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,
More informationMINI DIAPHRAGM VACUUM PUMPS
MINI DIAPHRAGM VACUUM PUMPS DATA SHEET E 024 N 815 KNE N 828 KNDC-B N 838 KNDC Concept The mini diaphragm gas sampling pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its
More informationOPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP
This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!
More informationModel 2851 CONSTANT FLOW REGULATOR
CONSTANT FLOW REGULATOR Model 2851 The model 2851 constant flow regulator is designed to provide constant flow of liquids or gases regardless of pressure variations. It is intended for low liquid flows
More informationPressure Relief Valve DHV 718
Pressure Relief Valve DHV 718 Nominal size DN 8 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 0.5 to 10 bar diaphragm controlled pressure relief valve simple design,
More informationSP/ST/SA Models Pulse-input and Analog-input Control
SP/ST/SA Pulse-input and -input Control Smart and Intuitive Operation Simple key functions and user interface for ease of operation. Range can be set between 1 and 3 strokes per minute in 1-stroke units.
More informationBeamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL
Beamex PG PRESSURE GENERATORS 97 Beamex PGM PGV PGC PGHH PGPH PGL Beamex PG pressure generators are portable hand-operated pressure generators and ultimate field calibration pumps 98 Calibration pumps
More informationWater valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE
MAKING MODERN LIVING POSSIBLE Data sheet Water valve Type WVO Water valve type WVO is used for regulating the flow of water in refrigeration plant with water-cooled condensers. The water valve gives modulating
More informationMICRO DIAPHRAGM LIQUID PUMPS DATA SHEET NF 100/1.100 NF 100 / 1.100
MICRO DIAPHRAGM LIQUID PUMPS DATA SHEET /1.100 / 1.100 KP.51 DC NF 1.100 KPE KP.27 AA Concept KNF diaphragm liquid pumps are based on the principle of the oscillating displacement pump which is remarkably
More informationFiltration FILTRATION PRODUCT TIPS
Filtration 195 18 Proved and tested, durable, optimally resistant against acids, caustic solutions and other aggressive chemicals: our solutions for efficient and safe filtration. PRODUCT TIPS BOLA Filtration
More informationPRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES
PRESSURE REGULATORS ALL MEDICAL GASES In this section we propose our pressure regulators (FM series, MU and MERCURY ) and our Rs flowmeters for applications other than oxygen therapy (presented in the
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 2400 N 2400.15 ST.9 E Concept The diaphragm pumps from KNF arebased on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its
More informationDIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM
DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external
More informationDiaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860
PROCESS Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 Single & Twin-Head Designs OEM Installation Models UN860FTI EX UN726.3STI EX UN726.3FTI
More informationElectronic relative and differential pressure switch type 616
Electronic relative and differential pressure switch type 616 Pressure range 0... 0.1 25 bar The switching points of the pressure switch type 616 can be potentiometer adjusted by the customer, or set in
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATASHEET N 143 N 143 SP.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central
More informationPilot valves for pilot operated servo valves
Data sheet Pilot valves for pilot operated servo valves The range of pilot valves consists of: Constant-pressure pilot valve, type CVP (LP) and CVP (HP) Differential-pressure pilot valve, type CVPP (LP)
More informationWillkommen. Welcome to KNF - presentation
Willkommen Welcome to KNF - presentation KNF modular system, way to Project pump heads available in: - aluminium - plastics (PPS, Peek ) - stainless steel - PTFE diaphragms und valves available in: - Neopren
More informationSelf-operated Regulators Accessories Differential Pressure and Flow Regulators
Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application
More informationPressure transmitters EMP 2
Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,
More informationSIMDOS 02 DIAPHRAGM METERING PUMP
LAB FEM1.02.18 OPERATING INSTRUCTIONS SIMDOS 02 DIAPHRAGM METERING PUMP Before operating the pump and the accessories, please read the operating instructions and pay attention to the safety precautions.
More informationSchroeder Check Test Point System
Perforated polyamide / kevlar hose, 2 mm ID, 5 mm OD, plastic dust cap. L in (mm) P (max) psi (bar) 6 (150) 10,000 (680) 12 (300) 10,000 (680) 24 (610) 10,000 (680) 36 (915) 10,000 (680) 48 (1220) 10,000
More informationSIMDOS 10 DIAPHRAGM METERING PUMP
LAB FEM1.10.18 2 OPERATING INSTRUCTIONS SIMDOS 10 DIAPHRAGM METERING PUMP Before operating the pump and the accessories, please read the operating instructions and pay attention to the safety precautions.
More informationBest Practices for Installation of Gaseous Sample Pumps
Best Practices for Installation of Gaseous Sample Pumps Goal of the Gas Sample Pump Transport a clean, reliable, sample of the process gas to the analyzer, in the safest and easiest way possible, to ensure
More informationB74G - EXCELON Modular System General purpose filter/regulator
> Port size: /8... / (ISO G/PTF) > Excelon design allows in-line installation or modular installation with other Excelon products > Push to lock adjusting knob with optional tamper resistant accessory
More informationDifferenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar
692 Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle 0 0.1 25 bar E Technical overview The differential pressure transmitter of type series 692 with
More informationPRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES
PRESSURE REDUCTION FLOWMETERING, QUICK COUPLING PROBES AND ACCESSORIES 1 3 1 - ALPINOX: oxygen Regulator - Medical oxygen regulator with flowmeter. - Medical oxygen regulator with flowmeter and Quick
More informationTECHNOLOGIES. M Series. Positive return metering pumps [API675]
M Series Positive return metering pumps [API675] Hydraulic double diaphragm metering pump in AISI 316L stainless steel A line of plunger and hydraulic double diaphragm metering pumps designed according
More informationOperating Instructions
Operating Instructions Multifunction Valve Contents Page Safety Instructions... 2 Unpacking... 2 Introduction... 2 Dimensions... 4 Installation...2-3 Description of Controls & Operation... 3 Page Helpful
More informationRK LEL Sample Draw Aspirator Adapter Operator s Manual
30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment
More informationHAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS
HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings
More informationROYTRONIC EXCEL TM Series AD Electronic Metering Pumps
0.20 5.1 ROYTRONIC EXCEL TM AD Electronic Metering Pumps LMI ROYTRONIC EXCEL AD pumps achieve a new level of innovation in solenoid-driven metering pump technology. Offering a robust design, micropressor
More informationAccessories. Valves. Adjustable Pressure Relief Valves
Valves djustable Pressure Relief Valves djustable pressure relief valves allow for variable operating pressures anywhere between PSI ( bar). In order to prevent overloading of the motor, however, the maximum
More informationHigh precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment
Fluid dose dispensing valve High precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment Provides the high productivity, stability, reliability,
More informationCSA Sample Draw Aspirator Adapter Operator s Manual
30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More information3/4 MPT w/ MHT Flush & Cap (80 psi) (A2)
4E PLASTIC FILTERS Debris Basin Typical Filter Components Shown 3/4 MPT w/ MHT Flush & Cap (80 psi) (A2) Note: All Plastic Filter models available drilled and tapped for 1/8 schrader valve. Contact customer
More information2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version
2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for
More informationHip Air Operated Valves
Hydraulic & Offshore Supplies Hip Air Operated s YOUR GATEWAY TO GLOBAL SUPPLY HOSE ASSEMBLIES PRESSURE TESTING WALFORM EQUIPMENT PACKAGES FLANGES PIPE & TUBE Air Operated s High Pressure Equipment Company
More informationProcess Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order
Process Pump /5 Series Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted areas.
More informationSIMDOS 02 DIAPHRAGM METERING PUMP
LAB FEM02.18 OPERATING INSTRUCTIONS SIMDOS 02 DIAPHRAGM METERING PUMP Before operating the pump and the accessories, please read the operating instructions and pay attention to the safety precautions.
More informationPrecision Pressure Regulators
hapter - Pressure Regulators Pressure range onnection thread Device Page 3 mm, high precision 0.0 2 / 8 bar G 1 8 RI.02 highly sensitive, max. 3 bar supply pressure 0.002 0.12 / 31 bar ¼"NPT R40.03 without
More informationFeatures. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)
1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings
More informationUsER manual for Watersens ph -REDOX
UsER manual for Watersens -REDOX Cl 8 1 2 6 3 3 7 7 4 4 4 4 Parts List 1 Redox Probe 1 x 2 PH Probe 1 x 5 Tube Weight 2 x 6 Connection Valve 1 x chlorine 3 Chlorine and Pumps 2 x 7 Dosing Valve 2 x 5 5
More informationR300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids
HELYON 5 Chemin du Jubin 69570 DARDILLY Tél. +33 (0)4 72 52 16 70 - Fax +33 (0)4 72 52 16 71 R300 Brass high pressure regulator, for compressed air, gas and liquids FEATURES Pressure regulator for inlet
More informationOXYGEN THERAPY FLOWMETERS, REUSABLE AND SINGLE-PATIENT HUMIDIFIERS, PRESSURE REGULATORS, FLOW SELECTORS
OXYGEN THERAPY The line of oxygen therapy devices includes variable area flowmeters, calibrated holes dial flowmeters, pressure reducers with their cylinder connections, humidifiers, flow selectors and
More informationV-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology
V-Major, V-Compact Reciprocating Compressors Intelligent Air Technology & Significant Energy Savings with Lower Running Costs Efficient. LOW POWER CONSUMPTION 75% of the running cost of an air compressor
More informationPressure switches for air and water CS
Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the
More informationData sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119
Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,
More informationMaximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications
Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range
More informationWaterSource Heat Pump Hose Kit Performance Specification-Summary
WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo
More informationX-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司
X-Flow Mass Flow Controller 2 Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow, a new easy to use general purpose mass flow controller for your instrument, lab, or
More informationCHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS
CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 9 N 9 FTE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its
More informationID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:
ID-Cube Installation and Operations Manual For ID-Cube Source and Power Supply Revision 2 Document #: 7.1.002 IonSense Inc. 999 Broadway Suite 404 Saugus, MA 01906 Copyright 2014 by IonSense Inc. All rights
More informationPanel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)
Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve) When working pressure change, inside diaphragm and needle valve operates in order to always keeping a fixed flow rate for exact
More informationHydraulic Accumulators with Back-Up Nitrogen Bottles
Hydraulic Accumulators with Back-Up Nitrogen Bottles 1. GENERAL To complete the accumulator range, HYDAC provides a variety of useful accessory products. They guarantee correct installation and optimum
More informationDescription Pressure range Connection thread Device Page bar
Pressure Regulator Pressure range onnection thread Device Page bar factory-set pressure artridge regulator 2 / 3 / 4 / 6 artridge 233.02 without exhaust 7 x 25 2 / 3 / /0 G¼ia R3.03 for liquids 34 x 52
More information215 Liquid Handler Up-Grade Manual
BRUKER NMR 220 25 Liquid Handler Up-Grade Manual For Up-Grade to Run with XWINNMR Vers.. Manual # H977 The kit will include: H9770 BEST NMR Up-Grade Kit to No. Article Bruker # Comment 500mm Capillary
More informationELADOS EDP L Diaphragm Metering Pump Type
ELADOS EDP L Diaphragm Metering Pump Type 04800-06700 Motor-driven diaphragm pump with integrated frequency converter High reserves due to a powerful asynchronous motor High flexibility due to variably
More informationPressure Reducing Valve DMV 755
Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to
More informationMICRO DIAPHRAGM GAS PUMPS
MICRO DIAPHRAGM GAS PUMPS DATA SHEET E 5 NMP 83 KNE NMP 85 KNDC NMP 85.1.2 KNDC-B Concept The micro diaphragm gas pumps from KNF are based on a simple principle an elastic diaphragm, fixed on its edge,
More informationDescription Supply pressure Pressure range Connection Device Page max. bar bar thread
Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4
More information1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits
/-Way Angle-Seat Valve Type 000 to - NPT; 0 to 30 Advantages / Benefits Spring return closed or open, double-acting Materials: bronze, stainless steel High flow rate Self-adjusting packing glands with
More informationMiniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800
KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationSuperFinish 27. Available versions. Accessories. SuperFinish 27 Spraypack. Basic unit. Tip extensions / pole guns. Suction systems.
Available versions Spraypack Basic unit 0341 051 basic unit on trolley including pressure gauge system + QuickClean suction + 15 m high pressure hose + Airless gun G 12 + Wagner Tip holder with Airless
More informationPowers Controls D Day-Night Thermostats
Powers Controls D Day-Night Thermostats Technical Instructions Document No. 155-073P25 TH 832-2 Description The D Day-Night or Two Temperature Thermostat is available as a room-type instrument. It is essentially
More informationRelative and differential pressure transmitter type 692
Relative and differential pressure transmitter type 692 Pressure range 0... 0.1 25 bar Type 692 pressure transmitters have a unique, well proven ceramic technolgy. There are variety of pressure and electrical
More informationLPK1230 Hydraulic Crimping Tool 12 ton
SPECIFICATIONS AND PARTS LPK1230 Hydraulic Crimping Tool 12 ton Serial Code FYB Read and understand all of the instructions and safety information in this manual before operating or servicing this tool.
More informationWARNING. Work drop prevention check valves FPV series. Vacuum accessories. Safety handling of workpiece with several pads
Work drop prevention check valves series Safety handling of workpiece with several pads Enable using one CONVUM ejector and several pads, in applications where some of the suction pads may not be in contact
More informationSPD310/SPD360 Air Differential
SPD310/SPD360 Air Differential Pressure SPD310 / SPD360 SPD310 / SPD360 differential pressure transmitters are intended for use in air handling systems for the monitoring of air ducts, filters and fans.
More informationGas Filters DN15 DN300. delta-elektrogas.com EE151 03/17
FG Gas Filters DN15 DN300 delta-elektrogas.com EE151 03/17 FG Gas Filters Contents Description.. 2 Features.. 2 Functioning and application. 3 Technical specifications 4 Gas flow chart (pressure drop)
More informationLRS(H)4 Pressure-Reducing Regulator User Manual
LRS(H)4 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be considered
More information1200 Series Pressure Regulators
SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of
More informationTF- & DM-Series. Turbineflowmeter
Turbineflowmeter .. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation
More informationFLOWMETER UNITS FLOWMETER DEVICES, BY-PASS SYSTEMS
FLOWMETER UNITS The range of anesthesia flowmeter units series FM, SF and RM, available in different configurations, makes it possible to offer many options to meet various requirements in the operating
More informationAirless-Spraying Equipment. SuperFinish31. Fully equipped. More power. Innovative QLS technology
Airless-Spraying Equipment SuperFinish31 Fully equipped More power Innovative QLS technology New technology, fully equipped with even more power. This is the new SuperFinish 31 Airless spraying equipment,
More informationBSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.
1 2 Standard Pressure Sensor with display Overview Pressure Range Relative nominal Overload Burst Permitted negative -1..2 bar 2 bar 4 bar 10 bar -1..10 bar 10 bar 20 bar 35 bar 0..2 bar 2 bar 4 bar 10
More informationLocator Locator-D-Lux Air-Saver G1 Air-Saver G2
170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale
More informationPressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar
Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at
More informationR133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid
R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder
More informationLow Pressure Diaphragm Sealed Pressure Gauges (571P & 573P Sereies)
Applications Low pressure measuring Specially designed for chemical, petrochemical, paper and food industry All gaseous and liquid media Corrode, Suspended solid, Viscous or Frozen medium Shock & vibration
More informationGRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz
GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical
More informationRK-IR Sample Draw Aspirator Adapter Operator s Manual
30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment
More informationPocket Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:
Pumps models are ideal for low flow, low pressure metering applications. The pump is constructed entirely of plastic and utilizes GRI s time-proven bellows technology to provide an accurate chemically-resistant
More informationSKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function
SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25
More informationPressure relief valve DHV 718
Pressure relief valve DHV 78 Benefits diaphragm controlled pressure relief valve with piston guidance simple design, reliable function particularly suitable for oscillating pumps constant, frictionless
More information/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651
/ Air Line Kit AL - M1202 / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651 002 1 Thank you for purchasing the Air Line Kit " AL - M1202 ". This Air Line Kit is designed to adjust the air supply
More informationInstallation Instructions
Installation Instructions S65-135 (Circular) S65-136 (Semi-Circular) Air Valve Retrofit For Non-Sectional Classic Washfountain Table of Contents.......................2-6 Metering Air Valve Parts List....................6
More informationINDUSTRIAL PNEUMATICS - air treatment units. FIL filter
Due to its metal construction, the entire range of NEW DEAL elements is resistant to heavy duty working conditions. Designed for high pressure application (up to 18 bar). FIL filter Degree of filtration:
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationCHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS
CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 922 N 922 FTE Concept The diaphragm pumps from KNF are based on a simple principle - an elastic diaphragm, ixed on its edge, moves up and
More informationOperating Instructions Models and Hydrostatic Test Pumps
Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex
More informationDIAPHRAGM VACUUM PUMPS AND COMPRESSORS
DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 16 N 35 ANE with IP 2 motor Concept The diaphragm pumps from KNF are based on a simple principal - an elastic diaphragm, ixed on its edge, moves up and
More information