Watthour Meter (Transducer Type) - PWK

Size: px
Start display at page:

Download "Watthour Meter (Transducer Type) - PWK"

Transcription

1 Watthour Meter (Transducer Type) PWK WATTHOUR METER (Transducer AllInOne Type) (1) Application Type Rating (2) Voltage side Current side PWK120NC12 110V, 5A (1A) 2VA 1VA PWK100NC12 220V, 5A (1A) 3.5VA 1VA 3wire 3wire PWK120NC13 PWK100NC13 110V, 5A (1A) 2VA 1VA PWK120NC33 110V, 5A (1A) 2VA 1VA PWK100NC33 220V, 5A (1A) 3.5VA 1VA 4wire PWK120NC34 110/ 3V, 5A (1A) 2VA 1VA PWK100NC V, 5A (1A) 3.5VA 1VA (1) Please refer to (page 18) for manufacture limit and max. scale value. (2) Please use external CT, 5A(1A) or VT, 110V respectively if above rating is exceeds. watthour meter 3wire watthour meter 3wire watthour meter 4wire watthour meter Type A B C D F1 F2 G1 G2 weight (g) PWK120NC Ф 112ФHole M5 Screw 7ФHole 510 PWK100NC Ф 87ФHole M4 Screw 5.5ФHole

2 VAR METER (Transducer AllInOne Type) (1) Var Meter (Transducer Type) PWVK 3wire 4wire PWVK120NC12 110V, 5A (1A) 2VA 1VA PWVK100NC12 220V, 5A (1A) 3.5VA 1VA PWVK120NC33 110V, 5A (1A) 2VA 1VA PWVK100NC33 220V, 5A (1A) 3.5VA 1VA PWVK120NC34 110V, 5A (1A) 2VA 1VA PWVK100NC34 220V, 5A (1A) 3.5VA 1VA (1) Please refer to (page 18) for manufacture limit and max. scale value. Standard scale: Lead var~0~lag var (2) Please use external CT, 5A(1A) or VT, 110V respectively if above rating is exceeds. var meter 3wire var meter 4wire var meter Type A B C D F1 F2 G1 G2 weight (g) PWVK120NC Ф 112ФHole M5 Screw 7ФHole 510 PWVK100NC Ф 87ФHole M4 Screw 5.5ФHole

3 Watthour Meter (Transducer Type) PWK WATTHOUR METER (External with Transducer Type) (1) (Transducer) PWK80C12 110V, 5A (1A) 2VA 1VA 60C12 220V, 5A (1A) 3.5VA 1VA WT62M12 3wire PWK80C13 60C13 110V, 5A (1A) Each phase 2VA Each phase 1VA WT83M13 PWK80C33 110V, 5A (1A) Each phase 2VA Each phase 1VA 60C33 220V, 5A (1A) Each phase 3.5VA Each phase 1VA WT83M33 4wire (3) PWK80C34 110/ 3V, 5A (1A) Each phase 1.5VA Each phase 1VA 60C34 220/ 3V, 5A (1A) Each phase 3VA Each phase 1VA WT83M34 (1) Please refer to (page 18) for manufacture limit and Max. scale value. (2) If above rating is exceeds, please use external CT, 5A(1A) or VT, 110V respectively. Usable voltage range: 110V: 90~130V; 220V: 180~260V (3) 4wire is voltage balanced. For High harmonic ware use, please specify the frequency. For SCR Wareform Meter PWK CH Aux. power is necessary. ( 4wire can not manufacture) watthour meter external with WT62M12 3wire & watthour meter external with WT83M13/ 33 4wire watthour meter WT83M34 For Type: T62M For Type: T 83M Type A B C D E F1 F2 G1 G2 K weight (g) PWK80C Ф 67ФHole M3 Screw 4ФHole PWK60C Ф 54ФHole M3 Screw 4ФHole

4 Var Meter (Transducer Type) PWVK VAR METER (External with Transducer Type) (1) (3) PWVK80C12 110V, 5A (1A) 2VA 1.5VA 60C12 220V, 5A (1A) 3.5VA 1.5VA (Transducer) WVT62M12 (balanced) (4) (unbalanced) (4) 4wire (unbalanced) (4)(5) PWVBK80C33 110V, 5A (1A) Each phase 2VA Each phase 1VA 60C33 220V, 5A (1A) Each phase 3.5VA Each phase 1VA PWVK80C33 110V, 5A (1A) Each phase 2VA Each phase 1VA 60C33 220V, 5A (1A) Each phase 3.5VA Each phase 1VA PWVK80C34 110V, 5A (1A) Each phase 2VA Each phase 1VA 60C34 220V, 5A (1A) Each phase 3.5VA Each phase 1VA WVBT83M33 WVT83M33 WVT83M34 (1) Please refer to (page 18) for Manufacture limit and Max. scale value. Standard scale: Lead var~0~lag var (2) If above rating is exceeds, Please use external CT, 5A(1A) or VT, 110V respectively. (3) Please specify the frequency (50Hz or 60Hz) for single phase circuit. (4) Please use, 4wire in positive phase sequence. (5) 4wire is voltage balanced. var meter external with WVT62M12 3wire & var meter external with WVT83M13/ 33 4wire var meter external with WVT83M34 For Type: T62M For Type: T 83M Type A B C D E F1 F2 G1 G2 K weight (g) PWV(B)K80C Ф 67ФHole M3 Screw 4ФHole PWV(B)K60C Ф 54ФHole M3 Screw 4ФHole

5 Watthour Meter & Var Meter (Transducer Type) PWK / PWVK MANUFACTURABLE RANGE MAX. SCALE VALUE FOR INTRINSIC METER Manufacturable range will be limited where intrinsic max. scale value is within the scope as shown in the right list. But in the case, the meter is used with external CV or VT, max. scale value will be calculated as following formula: Intrinsic Max. scale value = Max. scale value VT ratio CT ratio Type Name Rating Manufacturable Intrinsic Max. Scale Value Watthour Meter Var Meter 110V / 5A(1A) 350~600W (70~120W) 350~600var (70~120var) 220V/ 5A(1A) 700~1200W (140~240W) 700~1200var (140~240var) 3wire 110V / 5A(1A) 600~1200W (120~240W) 3wire 110V / 5A(1A) 600~1200W (120~240W) 600~1200var (120~240var) 220V / 5A(1A) 1200~2400W (240~480W) 1200~2400var (240~480var) Line Phase Current 4wire 110V 110/ 3V 5A(1A) 600~1200W (120~240W) 600~1200var (120~240var) 220V 220/ 3V 5A(1A) 1200~2400W (240~480W) 1200~2400var (240~480var) REFERENCE LIST FOR STANDARD MAX. SCALE VALUE THREE PHASE WATTMETER The following table is the standard of wattmeter. This table also applies for 4wire wattmeter, single pahse 3wire watthour meter and var meter. Standard for single phase wattmeter calculation is: the listed value 1/2 Line vol. CT ratio 5/5A V (VT6600/110V) V (VT3300/110V) V (VT440/110V) 7.5/5A /5A /5A /5A /5A /5A /5A /5A /5A /5A /5A /5A /5A /5A /5A /5A /5A /5A /5A /5A /5A /5A 10MW /5A 12MW 10MW /5A 15MW 12MW 10MW /5A 20MW 15MW 12MW 10MW V V

Current transformers Measurement devices from 5 to 5000 A

Current transformers Measurement devices from 5 to 5000 A Metering, monitoring & power quality trafo_108_a_1_cat Current transformers Three-phase CT trafo_012_a_1_cat The solution for > ndustry. > Service sector. Strong points trafo_077_b_1_cat trafo_010_a_1_cat

More information

Current transformers. Measurement devices. 2 General Catalogue SOCOMEC. Measurement devices NEW. ÂÂEnergy efficiency

Current transformers. Measurement devices. 2 General Catalogue SOCOMEC. Measurement devices NEW. ÂÂEnergy efficiency NEW trafo_108_a_1_cat Three-phase CT trafo_010_a_1_cat trafo_077_b_1_cat trafo_012_a_1_cat ÂÂEnergy efficiency 0.2s We offer class 0.2s for your energy efficiency or MD applications. appli_294_a ÂÂFunction

More information

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42

More information

trafo_011_a_1_cat Bar or cable-through Multiple applications per: - cables: Ø 17 to Ø 100 mm, - bars: 20 x 5 mm to 2 x 125 x 10 mm.

trafo_011_a_1_cat Bar or cable-through Multiple applications per: - cables: Ø 17 to Ø 100 mm, - bars: 20 x 5 mm to 2 x 125 x 10 mm. Current transformers Measurement devices trafo_012_a_1_cat trafo_077_b_1_cat trafo_010_a_1_cat trafo_008_a_1_cat trafo_011_a_1_cat Functions SOCOMEC current transformers deliver to the secondary a standard

More information

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a ATMOSPHERE APS TM Series Haze Generator MAX APS TM Series Fog Generator USER GUIDE No: 120815, Revision A/a MADE IN CANADA FABRIQUÉ AU CANADA Les Générateurs de Brouillard Ltée / Fog Generators Ltd 10301

More information

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

References 6 k thermal overload relays, adjustable from 0.11 to 16 A s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure

More information

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners 7 634 VGS1... with AGA67 connector VGS2... with AGA67 connector Solenoid gas valve VGS The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners The VGS and

More information

Electrical Shore Connections

Electrical Shore Connections RULES FOR CLASSIFICATION OF Ships / High Speed, Light Craft and Naval Surface Craft PART 6 CHAPTER 29 NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS Electrical Shore Connections JULY 2014

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary

More information

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,

More information

Electronic Turbine Meter TERZ 94

Electronic Turbine Meter TERZ 94 Electronic Turbine Meter TERZ 9 PRODUT INFORMTION Reliable Measurements of Gas EETRONI TURINE METER TERZ 9 Methode of operation, construction 2 Methode of operation The TERZ 9 electronic turbine meter

More information

Speed Controller ADR 40 Condensing pressure controller SPEED REGULATORS FOR ASYNCHRONOUS SINGLE PHASE MOTORS SERIES ADR 40 ADR 40 ADR 40 PP

Speed Controller ADR 40 Condensing pressure controller SPEED REGULATORS FOR ASYNCHRONOUS SINGLE PHASE MOTORS SERIES ADR 40 ADR 40 ADR 40 PP SPEED REGULATORS FOR ASYNCHRONOUS SINGLE PHASE MOTORS SERIES ADR 40 ADR 40 ADR 40 PP Control by pressure or temperature Pressure control 0-50 bar for all refrigerants Temperature control -20 to +100 C

More information

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual

陕西创威科技有限公司. Shaanxi Creat Wit Technology Co., Ltd. Precision pressure calibrator-cwy300 Operating Manual Precision pressure calibrator-cwy300 Operating Manual 陕西创威科技有限公司 Shaanxi Creat Wit Technology Co., Ltd Tel: +86 029 86690023 Fax: +86 029 86690023 Mob: +86 18202956927 Email: sales@creatwit.com Content

More information

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications. Sanitary RTD Temperature sensor TH17 Compact Instructions Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications. The single element RTD is specifi cally designed

More information

RMG Meßtechnik GmbH. Publication No E

RMG Meßtechnik GmbH. Publication No E Electronic Turbine Meter TERZ 94 RMG Meßtechnik GmbH Publication No. 3.174-E P.O.ox 280 35502 utzbach (Germany) Tel.: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Internet: http://www.rmg.de

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e Mounting instructions Strain transducer SLB-700A B 26.SLB700A.10 e SLB700A 3 Contents Page Safety instructions.............................................. 4 1 Applications..................................................

More information

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual

More information

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters

More information

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS CONSTRUCTION FEATURES ENCLOSURE OPERATING TEMPERATURE 20 C/+60 C COVER Diecast aluminium (anodised) WEIGHT CSN 5 3.5 kg CSN 8 5 kg CSN

More information

TECHNICAL MANUAL CALIBRATION INSTRUCTIONS FUEL PRESSURIZING & DUMP VALVE TEST STAND 1TL

TECHNICAL MANUAL CALIBRATION INSTRUCTIONS FUEL PRESSURIZING & DUMP VALVE TEST STAND 1TL TECHNICAL MANUAL CALIBRATION INSTRUCTIONS FUEL PRESSURIZING & DUMP VALVE TEST STAND 1TL32-6228-1 Rev 1.0 3-Oct-2008 PWA 15090G-OC001 DISCLOSURE NOTICE: This information is furnished upon the condition

More information

Note: All batteries are supplied with only a residual charge and should be charged at the continuous charge rate before use.

Note: All batteries are supplied with only a residual charge and should be charged at the continuous charge rate before use. RS Stock number 199-769 Description: For use in emergency lighting units and back-up applications. Voltage is 1.2V Note: All batteries are supplied with only a residual charge and should be charged at

More information

FMU4X, FMC4X FMU4P, FMC4P

FMU4X, FMC4X FMU4P, FMC4P ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

Item Parameter Min Typical Max Unit. VCC Working Voltage V. PH Heating consumption mw. RH Heater resistance - 31±10% - Ω

Item Parameter Min Typical Max Unit. VCC Working Voltage V. PH Heating consumption mw. RH Heater resistance - 31±10% - Ω Gas Sensor (MQ5) Description The AZL- Gas Sensor (MQ5) module is useful for gas leakage detection (in home and industry). It is suitable for detecting H2, LPG, CH4, CO, Alcohol. Due to its high sensitivity

More information

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES

TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES ALL PICTURES SHOWN ARE FOR REFERENCE ONLY ACTUAL PRODUCT MAY VARY

More information

MaxSB - Low Voltage Switchboard

MaxSB - Low Voltage Switchboard BU 3101 Low Voltage Systems, March 2009 Low Voltage Systems MaxSB - Low Voltage Switchboard May 5, 2009 Slide 1 MaxSB Product Overview Description Value Rated Main bus current 1600A, 2000A, 3000A, 3200A,

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 10770-3 First edition 2007-10-15 Hydraulic fluid power Electrically modulated hydraulic control valves Part 3: Test methods for pressure control valves Transmissions hydrauliques

More information

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA S06 & S02 Valve Proving System Installation Instructions USA CDN Table of Contents Table of Contents... Page 1 Approvals... Page 1 Attention... Page 1 Specification... Page 2 Mounting.... Page 3 Wiring...

More information

Aquavar SOLO 2 Frequently Asked Questions

Aquavar SOLO 2 Frequently Asked Questions Aquavar SOLO 2 Frequently Asked Questions How do I size the Aquavar SOLO 2 for the appropriate pump/motor combination? Can I use a 208 Volt motor? Can I run the Aquavar SOLO 2 up to 80HZ? What are the

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

CP3R Quick Start Manual

CP3R Quick Start Manual RUN MON PRM PU EXT NET RUN D700 3 200V RUN MON PRM PU EXT NET RUN D700 3 200V CP3R Quick Start Manual for Constant Pressure Applications This CP3R Drive has been factory pre-programmed for your specific

More information

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11

Safety. Operating instructions Magnetic relief valve VAN DANGER. Contents WARNING CAUTION. Changes to edition 11.11 0084 Edition 0. D F L I E DK S P GR TR CZ PL RUS H www.docuthek.com Operating instructions Magnetic relief valve Translation from the German 0 Elster GmbH Contents Magnetic relief valve... Contents...

More information

LEA_EN_PZL Dynamometric Scale. Instruments and Systems for Geotechnical and Structural Monitoring

LEA_EN_PZL Dynamometric Scale.   Instruments and Systems for Geotechnical and Structural Monitoring LEA_EN_PZL8001001 Dynamometric Scale LEA_EN_PZL8001001 Dynamometric Scale Description _ The dynamometric scale is a precise, reliable and rugged instrument. The instrument was installed on different dams

More information

Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.

Process Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE. Process Solutions Electronic Turbine Meter TERZ 9 PROVEN TEHNOOGY. SUPERIOR PERFORMNE. Electronic Turbine Meter TERZ 9 Method of Operation The TERZ 9 electronic turbine meter is a flow meter which directly

More information

CERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB Audio, video and similar electronic apparatus Safety requirements

CERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB Audio, video and similar electronic apparatus Safety requirements Page 1 of 7 CERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB 8898 2011 Audio, video and similar electronic apparatus Safety requirements This analysis is intended to identify and analyze

More information

System Pressure Manager Standard & System Pressure Manager Plus

System Pressure Manager Standard & System Pressure Manager Plus System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

700 SERIES BMS II BUBBLER MONITORING SYSTEM

700 SERIES BMS II BUBBLER MONITORING SYSTEM 1 700 SERIES BMS II BUBBLER MONITORING SYSTEM VISIT OUR WEBSITE AT SIGMACONTROLS.COM 700 SERIES BMS II MANUAL 062114 2 TABLE OF CONTENTS INTRODUCTION 3 Physical Specifications WIRING 5 PROGRAMMING & SETUP..

More information

CPN1 Quick Start Manual

CPN1 Quick Start Manual RUN MON PRM PU EXT NET RUN RUN MON PRM PU EXT NET RUN CPN1 Quick Start Manual for Constant Pressure Applications This CPN1 Drive has been factory pre-programmed for your specific pressure control application.

More information

Pressure switch KP-E. Data sheet

Pressure switch KP-E. Data sheet Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches

More information

Service Instructions. Syntron Control Model: CSCR-1-B (115V)

Service Instructions. Syntron Control Model: CSCR-1-B (115V) Service Instructions Syntron Control Model: CSCR-1-B (115V) Syntron CSCR-1-B (115V) Control INSTALLATION OPERATION MAINTENANCE Thank you for buying your equipment from Syntron Material Handling. This manual

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories

More information

D e s c r i p t i o n

D e s c r i p t i o n MPS Series D e s c r i p t i o n The MPS spin-on filter series is a complete product range suitable, for both suction and return applications. Utilising spin-on canisters, the MPS series are quick and

More information

FENCER Under Cabinet LED Light Fixture

FENCER Under Cabinet LED Light Fixture 1.877.817.6028 www.diodeled.com FENCER Under Cabinet LED Light SABER Traditional design FOIL Modern slim design The FENCER fixture represents a new generation of under cabinet lighting for kitchens and

More information

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4 to 1 NPT SERIES. qwer Air and Inert Gas Valves Brass, or Stainless Steel Bodies 1/" to 1" NPT Features Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting

More information

Ripple Tank. Equipment:

Ripple Tank. Equipment: Ripple Tank Two point source interference patterns Purpose: A single vibration applied to the surface of water produces circular waves that propagate out from that point. If two identical vibrations are

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) DOCUMENT NO: STP 2203 VERSION: 2008-07-01 Page 1 of 6 1.0 PURPOSE This test procedure is used by the Electrical Safety

More information

GAS FUEL VALVE FORM AGV5 OM 8-03

GAS FUEL VALVE FORM AGV5 OM 8-03 ALTRONIC AGV5 OPERATING MANUAL GAS FUEL VALVE FORM AGV5 OM 8-03 WARNING: DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE PERSONAL INJURY TO OPERATORS

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Unlimited possibilities. Get started in no time

Unlimited possibilities. Get started in no time Unlimited possibilities The patented KCFiLL machine is designed by Kosan Crisplant s engineers for easy, safe and accurate LPG filling, and offers the best value for money on the market for low-capacity

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:

More information

Product Specification

Product Specification Ultrasonic Cold Water Meter Body Part Number: HS0014-000 Model Number: RC15/HS-US0004-000-01 Overview The Ultrasonic Cold Water Meter Body is comprised of a pair of ultrasonic flow sensors and a DN15 polymer

More information

Automatic Valve Proving Control

Automatic Valve Proving Control ISO 9001 Automatic Valve Proving Control 7 696 LDU11 UL recognized FM approved Features Performs leak test of the gas shut-off valves before start-up and/or immediately after burner shut-down No inlet

More information

Smart Water Application Technologies (SWAT)

Smart Water Application Technologies (SWAT) Smart Water Application Technologies (SWAT) Turf and Landscape Irrigation Equipment PRESSURE REGULATING SPRAY HEAD SPRINKLERS Equipment Functionality Test Testing Protocol Version 3.0 (May 2012) Developed

More information

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions

COOPER POWER SERIES. 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles installation instructions Voltage Regulators MN800013EN Effective February 2016 Supersedes S800-70-1 August 2012 COOPER POWER SERIES 50 A 2:1 series multiple (dual voltage) switch cap/wrench, lever or hotstick operable handles

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Application of CHE100 in Frequency Conversion Alteration of Air Compressor System

Application of CHE100 in Frequency Conversion Alteration of Air Compressor System Application of CHE100 in Frequency Conversion Alteration of Air Compressor System Abstract: This paper describes application of CHE100 in frequency conversion alteration of the air compressor system and

More information

Welcome to a NECA Webinar based on the National Electrical Code. This seminar is the second in a series of electrical grounding and bonding Webinars

Welcome to a NECA Webinar based on the National Electrical Code. This seminar is the second in a series of electrical grounding and bonding Webinars Welcome to a NECA Webinar based on the National Electrical Code. This seminar is the second in a series of electrical grounding and bonding Webinars presented by NECA. This Webinar topic is system grounding.

More information

Pneumatic pressure switch 20DD

Pneumatic pressure switch 20DD Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better

More information

TH3M TM48S SH3C and SH3BA Series Multi Range Timer

TH3M TM48S SH3C and SH3BA Series Multi Range Timer TH3M TM48S SH3C and SH3BA Series Multi Range Timer Features 1. Products Classification: Multi range timer. 2. Surface mount (N type) or flush mount (Y type) Compatible with standard 8 hole socket. 3. 15

More information

Certificate of compliance

Certificate of compliance Bureau Veritas Consumer Products Services Germany GmbH Businesspark A96 86842 Türkheim Germany + 49 (0) 40 740 41 0 cps-tuerkheim@de.bureauveritas.com Certification body of BV CPS GmbH Accredited according

More information

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers

Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers Summary of Substantive Changes between the 2004 e1 and 2017 editions of ASSE 1011, Hose Connection Vacuum Breakers Presented to the IAPMO Standards Review Committee on October 15, 2018 General: The changes

More information

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Type 0404 / 5404 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

speed monitor swe-compact

speed monitor swe-compact speed monitor swe-compact opto-electronic leaflet no. Kiepe 114 general The electronic rotational speed monitor SWE-compact comprises constructively the opto-electronic pulse transducer, the speed analysing

More information

DK46 - DK800 Supplementary instructions

DK46 - DK800 Supplementary instructions DK46 - DK800 Supplementary instructions Variable area flowmeter Device category II2G with electrical internals Additional Ex manual KROHNE CONTENTS DK46 - DK800 1 Safety instructions 3 1.1 General... 3

More information

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical

More information

Columbus Instruments

Columbus Instruments 0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011

More information

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014 Air Purge Unit Series: LSP-compact Type: EJG 2-2 (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014 Headquarters Sales Office BENELUX Intra-Automation GmbH B. V. Intra-Automation HTP

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S06* Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Digital Mass Flow Meters and Controllers for Gases

Digital Mass Flow Meters and Controllers for Gases Digital Mass Flow Meters and Controllers for Gases A Bronkhorst company. M+W Instruments. Your specialists for inline measurement WORTH KNOWING M+W Instruments was founded in 1988 and has always specialised

More information

SEMEM3-65 Servicing anaesthetic and ventilation equipment

SEMEM3-65 Servicing anaesthetic and ventilation equipment Overview This unit identifies the competences you need to carry out servicing activities on anaesthetic and ventilation equipment, in accordance with approved procedures. You will be required to service

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2419437 Master Contract: 203012 Issued to: ABB Automation Products GmbH 72 Schillerstrasse Minden, 32425 Germany Attention: Ralf Schaffer The products listed below

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S02 Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

Orifice Plate Flow Meter

Orifice Plate Flow Meter Orifice Plate Flow Meter FOFT Measuring Principle The principle of measuring the differential pressure is based on the fact that a differential pressure is created across that section of a pipe where its

More information

Tie Breaking Procedure

Tie Breaking Procedure Ohio Youth Basketball Tie Breaking Procedure The higher seeded team when two teams have the same record after completion of pool play will be determined by the winner of their head to head competition.

More information

2-jaw self-centering pneumatic parallel gripper (series SX)

2-jaw self-centering pneumatic parallel gripper (series SX) SX 2-jaw self-centering pneumatic parallel gripper (series SX) Double acting (normally closed on request). High gripping force. Protection class: IP67. Double O-Ring sealing on the columns. Suitable for

More information

Product Specification Spring Finger

Product Specification Spring Finger Product Specification 108-115008-3 Spring Finger Restricted to Sony Ericsson Mobile Communications 1. SCOPE 1.1. Content This specification covers the requirements for product performance test methods

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm

Dimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element

More information

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800 KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Airox Supportair Ventilator

Airox Supportair Ventilator Airox Supportair Ventilator A versatile hospital ventilator with a titration platform that enables a smooth transition to the patient s home care ventilator Titration Platform The Supportair ventilator

More information

Diaphragm pressure switches, 42 V

Diaphragm pressure switches, 42 V 0166 Diaphragm pressure switches, 42 V Zinc-plated steel body With push-on terminals Overpressure safe to 300 bar *) 0166 Diaphragm pressure switches Adjustment range Thread Normally open (no) : Normally

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

RTD Temperature sensor TH11

RTD Temperature sensor TH11 RTD Temperature sensor TH11 Compact Instructions Measuring System General purpose RTD with connection head TH11 for process and laboratory applications. The single element RTD is specifi cally designed

More information

(A) ±.060 ±.060 (A) NAMEPLATE NAMEPLATE n.004 A TOP TOP CONNECTIONS SLINGER PROTECTOR CONNECTIONS LINE

(A) ±.060 ±.060 (A) NAMEPLATE NAMEPLATE n.004 A TOP TOP CONNECTIONS SLINGER PROTECTOR CONNECTIONS LINE Dimensional Drawing VAR MODEL CUST. T. NO. A B C D H VOLTS SF AMS HZ RM CONN VOLTS ROT. DESCRITION / REMARKS 00 C55JXKAL58.6 / 5/0.85 6./. 60 450 AUTO 56J,BALL BEARING 00 C55JXKAL58.6 / 5/0.85 6./. 60

More information

INSTALLATION & MAINTENANCE INSTRUCTIONS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X

More information

HS653 Negative Pressure Ventilation Controller

HS653 Negative Pressure Ventilation Controller HS653 Negative Pressure Ventilation Controller General Installation Notes: Make sure that power is disconnected from system prior to servicing. Installation of this equipment and related OEM equipment

More information

Transformer Lifecycle Services. Container Id: Miscellaneous Id: Second Name: Sequence #:

Transformer Lifecycle Services. Container Id: Miscellaneous Id: Second Name: Sequence #: Report # 173396 Sample # 1 Transformer Lifecycle Services Received 08/09/2016 Date August 10, 2016 Serial Number: 100413030004 Substation Name: Colorado Bend Design Type: Core Type Manufacturer: HicoA

More information

MANUAL KPS Pressure Control Valve

MANUAL KPS Pressure Control Valve TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006

More information

2-Phase Filters(Direct IEC Connector) RoHS. 250V AC 50/60Hz 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, 25 / 85 / 21

2-Phase Filters(Direct IEC Connector) RoHS. 250V AC 50/60Hz 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, 25 / 85 / 21 2-Phase Filters(Direct IEC Connector) IG IM IL IX ID Rated Voltage/ Frequency 1,2,3,6,10A KC, UL, CSA, VDE+ENEC, TÜV, CQC, Climatic Category IG, IX, ID : IM, IL : Plastic Case IG, IX, ID : Screw and PCB

More information

Magnetic measurements (Pt. III) - AC

Magnetic measurements (Pt. III) - AC Magnetic measurements (Pt. III) - AC Ruslan Prozorov 24 February 2014 Physics 590B lock-in amplifier 24 February 2014 Basics of Magnetic Measurements. Part III (AC). Prof. Ruslan Prozorov 2 24 February

More information

MIL-STD-883G METHOD

MIL-STD-883G METHOD STEADY-STATE LIFE 1. PURPOSE. The steady-state life test is performed for the purpose of demonstrating the quality or reliability of devices subjected to the specified conditions over an extended time

More information

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d ATMOSPHERE APS Series Haze Generator MAX APS Series Fog Generator USER GUIDE No: 120815, Revision A/d MADE IN CANADA FABRIQUÉ AU CANADA Les Générateurs de Brouillard Ltée / Fog Generators Ltd 10301 avenue

More information

Tightness controls TC 1 3 and TC 4

Tightness controls TC 1 3 and TC 4 Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems

More information

Operation Manual Air Saver Unit ASV5000 Series

Operation Manual Air Saver Unit ASV5000 Series 9IM-V066-b Operation Manual Air Saver Unit ASV5000 Series Thank you for your choice of Kuroda Pneumatics LTDs product on this time. Please read this operation manual carefully and use the product correctly.

More information

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. General specifications. Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation

More information