D e s c r i p t i o n

Size: px
Start display at page:

Download "D e s c r i p t i o n"

Transcription

1 MPS Series

2 D e s c r i p t i o n The MPS spin-on filter series is a complete product range suitable, for both suction and return applications. Utilising spin-on canisters, the MPS series are quick and easy to service and provide a clean solution when changing elements. The filter elements are either resin-impregnated paper (ßx>), glass fibre (ßx³ ) or square wire mesh. The unique filter head is designed for both European CS and American CG standard canister series. One head design series accomodates both styles of elements. Also available is a new design utilizing a pressure differential visual and electrical indicators - ideal for lubrication applications. MPS filters are specifically designed for contamination control in hydraulic and lubrication circuits for mobile applications, agricultural and machine tool systems. The CW series of canister removes water from oil while filtering the oil at the same time. Water absorbent polymers up to 8 times their own weight, provide this major feature. Water holding capacities: - CW - 4 ml. CW ml. DIFFERENTIAL INDICATORS For Use with series 1 filter heads. New absolute filter elements independently tested in the following Institutes: For Use with series filter head. SUCTION INDICATORS ELECTRICAL VISUAL RETURN LINE INDICATORS VISUAL UNI EN ISO 91 N 37/98 ELECTRICAL MPS /3./UK

3 F i l t r a t i o n t e c h n o l og y element: Materials End caps: Galvanized steel Support tube: Galvanized steel Support frames: Galvanized steel with an epoxy coating A Series Inorganic microfibre Pre-filtration and External support media External wire mesh Inner support tube Internal wire mesh Microfibre filtration media Internal support media MP elements - Conform to the following ISO standards ISO Verification of collapse/burst resistance. ISO 94 - Verification of fabrication integrity and determination of the first bubble point. ISO Verification of material compatibility with fluids. ISO Method for end load test. ISO Verification of flow fatigue characteristics. ISO Evaluation of pressure drop versus flow characteristics. ISO Multi-pass method for evaluating filtration performance. Element material Absolute filtration A Series Inorganic microfibre with acrilic support Contamination retention as per ISO 16889: Multi-pass test. New improved ß ³ filter elements with greater efficiency and increased dirt holding capacity elements A3 A6 A1 Dimensions for ß (µm) values ß ³ ß ³ ß ³ 7 ß ³ (%) (9%) (98,7%) (99,%), , , N.B. Other materials giving different degrees of filtration are available on request. ß 8 1, Filtration ratios ß 1 ß > 1. > 1. >. > 1. ³ > 1. > 1, > 3 D P (bar) ing area elements CS-CG-CT A3/A6 A1/ Values in cm Element material Nominal filtration P Series Resin - impregnated paper M Series Square wire mesh (filtration degree is defined in microns by the maximum diameter of a sphere corresponding to the mesh size) ing area elements CS-CG-CT P1/P M CWSeries Resin - impregnated paper M6 M Values in cm CW 1 P1/P 3

4 S p e c i f i c a t i o n Materials Head Aluminium Bypass valve Nylon Working temperature Pressure filter body Collapse pressure filter elements Seals A Series: Nitrile (Buna-N) V Series: Viton Maximum working pressure up to Indicator Brass From - to +11 C For temperatures outside this range, please consult our Sales Network Organization 1 bar 4 bar Bypass valve Calibration pressure s of indicators for MPS series (MPS -7-1 ) and MST series Visual indicator Electrical indicator Bypass valve, differential opening pressure: S series:,3 bar ± 1% (MPS series only) R series: 1,7 bar ± 1% Description: MPS series filters are fitted with indicators 1 Kpa =.1 bar switching: Suction filters at a pressure of: kpa ± 1% Line filters at a pressure of: 1,3 bar ± 1% (MPS series only) Return filter at a pressure of: 1,3 bar ± 1% (MPS-MST series only) Suction filter: (MPS series only) VS vacuum switch Return and line filter VA Pressure gauge VR colour coded pressure gauge Suction filter (MPS series only) E Vacuum switch with change over contact Return filter ER Pressure switch with N.O. contacts EC Pressure switch with N.C. contacts s of indicators for MPS series 1 (MPS ) MPS filter series 1 ( and so on) are fitted with, differential style indicators. Visual indicator Electrical indicator Visual-electrical indicator scale - 76 cm Hg scale - 1 bar scale - 6 bar Operational information: 1V - Z1 Series for with bypass set switching at 1, bar ± 1% to 1,7 bar V6 - Z6 Series for without bypass switching at bar ± 1% N1 Series for with bypass set switching at 1, bar ± 1% to 1,7 bar N6 Series for without bypass switching at bar ± 1% 1E - K1* Series for with bypass set switching at 1, bar ± 1% to 1,7 bar E6 - K6* Series for without bypass switching at bar ± 1% *For K visual-electrical indicator, specify the voltage (il. K61 = LED: 4 volt) Switching at kpa ± 1% Max voltage: V 6 Hz Max current: A resistive, A inductive Protection degree IP6 Switching at 1,3 bar ± 1% Max voltage: 48V 6 Hz Max current:,a resistive,a inductive * 1-4 Volt { - 11 Volt 3-3 Volt

5 S p e c i f i c a t i o n Pressure differential indicator option K - E - N Series Supply voltage (/6 Hz) (V) Vca 1 Vca Vcc 3 Vcc 1 Vcc Resistive load (A),, Inductive load (A) 3,3,3 CONNECTOR DIN 436 ELECTRICAL CONNECTION E - N SERIES N.C. N.O. ELECTRICAL CONNECTION K SERIES N.C. N.O. Visual V series Visual Z series Ø16 G1/ Ø16 G1/ Electrical N series Visual led - Electrical K series Led Visual - Electrical E series, Ø16 G1/ Ø16 G1/ Ø16 G1/

6 S p e c i f i c a t i o n Fluid Compatibility head and bowls compatible for use with: mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 6743/4) water-based emulsions (types HFAE-HFAS as per ISO 6743/4) synthetic fluids (types HS-HFDR-HFDS-HFDU as per ISO 6743/4) water-glycol (types HFC as per ISO 6743/4) Seals A Series Nitrile (Buna-N) compatible with mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 6743/4) water-based emulsions (types HFAE-HFAS as per ISO 6743/4) water - glycol (types HFC as per ISO 6743/4) V Series Viton compatible with synthetic fluids (types HS-HFDR-HFDS-HFDU as per ISO 6743/4) elements As per ISO 943; suitable for mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 6743/4) and synthetic fluids (A and M series only) (types HS-HFDR-HFDS-HFDU as per ISO 6743/4) For water-based emulsions (types HFAE-HFAS as per ISO 6743/4) and fluids other than those mentioned, please consult our Sales Network Organization. International standards for contamination fluid control A general (no direct) comparison between ISO 446 and NAS 16 is given in table below. Contamination Correspondent Recommended Typical applications codes codes filtration ISO 446 NAS 16 degree 4µm(c) 6µm(c) 14µm(c) B x ³ High precision and laboratory servo-systems Robotic and servo-systems Very sensitive - high reliability systems Sensitive - reliable systems General equipment of limited reliability Low - pressure equipment not in continuous service

7 S e l e c t i o n & i n s t a l l a t i o n i n f o r m a t i o n elements types Pl eas e r e fe r t o A Series P Series M Series Absolute inorganic microfibre Nominal cellulose impregnated Metal mesh media, available in filtration media, available in paper media, available in 1, 6, and 9 micron. 3, 6, 1 and micron and micron. Example - M, M6 or M9. Example - A3, A6, A1 or Example - P1 or P in div i d ual pr e ss ur e dr o p cu r ve s t o ob t ai n f ilt er a ss emb ly pre ss ur e dr o p i n fo r mat io n The following filter sizing recommendations are based using a mineral oil fluid at 3 mm /s (cst) with a maximum total filter (housing and filter element) pressure drop of 3% of the filter condition indicator (.4 bar) for line and return filter and 8 kpa for suction filter. Indicator port for return line filter IN MPS -7 Series C - No. Threaded holes Ø 96 OUT Indicator port for suction line filter Lengths MPS 1-71 Series Indicator for suction filter MPS -7 (only for option G1-G) ø 4 B VS 9 9 EO 4 1/8 BSP Revolving PG 11 ø Cable 8/1 H H Indicator port Indicator for return filter MPS -7 (only for option G1-G) VR - VA A/F.14 ER - EC 6 43 A/F.4 Pg 7 MPS -71 Thread connections MPS SERIES -1 SIZES A3 A6 A1 P1 M6-M9 Flow rates with 3 mm /s fluid viscosity including filter element A B C G1 3/4 BSP 1/8 BSP M6 G 3/4 NPT 1/8 NPT 1/4 UNC G3 SAE 1-1 1/16-1 UN 1/8 NPT 1/4 UNC G4 SAE 8-3/4-16 UNF 1/8 NPT 1/4 UNC G 1 BSP 1/8 BSP M6 G6 1 NPT 1/8 NPT 1/4 UNC 1 7, MPS SERIES 7-71 SIZES A3 A6 A1 P1 M6-M SEE TABLE BELOW SEE TABLE BELOW 1, 1,3 Suction filter - Housing pressure drop ø 4, Indicator for line filter MPS 1-71 Led., Return line filter - Housing pressure drop,3, Z V N K E,

8 S e l e c t i o n & i n s t a l l a t i o n i n f o r m a t i o n Pl eas e r e fe r t o in div id ual pr e ss ur e dr o p cu r ve s t o o b t ai n f ilt er a ss e mb ly pre ss ur e dr o p i n fo r mat io n The following filter sizing recommendations are based using a mineral oil fluid at 3 mm /s (cst) with a maximum total filter (housing and filter element) pressure drop of 3% of the filter condition indicator (.4 bar) for line and return filter and 8 kpa for suction filter. Indicator por t for return line filter C - No. Threaded holes MPS SERIES 1-11 SIZES IN OUT Indicator por t for suction line filter Lengths MPS 1-11 H H A3 A6 A1 P1 M6-M /4 MPS SERIES 1-11 SIZES, Ø 19 MPS 1-1 Series 16 3 B MPS Series 8 Indicator port A3 A6 A /4,3 P1 M6-M /8 BSP Indicator for return filter MPS 1-1 (only for option G1) ø Indicator for suction filter MPS 1-1 (only for option G1) ø 4 VS VR - VA A/F.14 Indicator for line filter MPS EO ER - EC 6 43 A/F Thread connections Led Revolving PG 11 ø Cable 8/1 Pg 7. Flow rates with 3 mm /s fluid viscosity including filter element A B C G1 1 1/4 BSP 1/8 BSP M8 G 1 1/4 NPT 1/8 NPT /16 UNC G3 SAE - 1 /8-1 UN 1/8 NPT /16 UNC Suction filter - Housing pressure drop 1 7,, Return line filter - Housing pressure drop,4,3,, Z V N K E

9 & S e l e c t i o n i n s t a l l a t i o n i n f o r m a t i o n Pl e as e r e fe r t o in div i d ual pr e ss ur e dr o p cu r ve s t o o b t ai n f ilt e r a ss emb ly pre ss ur e dr o p i n fo r mat io n The following filter sizing recommendations are based using a mineral oil fluid at 3 mm /s (cst) with a maximum total filter (housing and filter element) pressure drop of 3% of the filter condition indicator (.4 bar) for line and return filter and 8 kpa for suction filter. MPS SERIES SIZES MPS - A A A / 4, P1 M6-M IN OUT MPS SERIES SIZES indicator (return) indicator (suction) A3 A6 Line Flow rate l/min * 18 1 Suction Flow rate l/min * 6 A / 4, P1 M6-M Flow rates with 3 mm /s fluid viscosity including filter element Ø 19 Lengths H H Thread connections G1 G G3 1 A 1 1/ BSP 1/8 BSP 1 1/ NPT 1/8 NPT SAE 4-1 7/8-1 UN B 1/8 NPT Suction filter - Housing pressure drop C M1 3/8 UNC 3/8 UNC Indicator for suction filter (only for option G1) VS 9 EO Revolving 7,, ø 4 PG 11 ø Cable 8/1 1/8 BSP Return line filter - Housing pressure drop,4,3 Indicator for return filter (only for option G1) ø 4 VR - VA A/F.14 ER - EC 6 43 A/F.4 Pg 7,,

10 S e l e c t i o n & i n s t a l l a t i o n i n f o r m a t i o n Please r e fe r t o in di v id ua l pr e ss ur e d r o p c ur ves t o o bt ai n f i l t e r a ss e m bl y p re ss ur e d r o p i n f or ma t io n The following filter sizing recommendations are based using a mineral oil fluid at 3 mm /s (cst) with a maximum total filter (housing and filter element) pressure drop of 3% of the filter condition indicator (.4 bar) for line and return filter and 8 kpa for suction filter. indicator (suction) indicator (return line) D indicator (suction) Indicator port for MPS indicator (return line) indicator (return line) Lengths Indicator for suction filter MPS 3-3 (only for option G1-G-F1) ø 4 VS Ø A OUT IN A 186 F - No. 4 Threaded holes 9 EO Revolving PG 11 ø Cable 8/1 MPS 3-31 H H Thread connections Flange MPS SERIES 3-31 SIZES A3 A6 A1 P1 M6-M9 Flow rates with 3 mm /s fluid viscosity A B C D E F connections F1 1 1/ SAE 3 PSI/M 1/8 BSP M1 69,8 3,71 M1 F 1 1/ SAE 3 PSI/UNC 1/8 NPT 1/ UNC 69,8 1 MPS SERIES 3-31 SIZES A3 A6 A1 P1 M6-M Line Flow rate l/min * Suction Flow rate l/min * including filter element 1 1/ 1 1/ A B G1 1 1/ BSP 1/8 BSP G 1 1/ NPT 1/8 NPT G3 SAE 4-1 7/8-1 UN 1/8 NPT,4,6 Suction filter - Housing pressure drop C M1 3/8 UNC 3/8 UNC 3,71 1/ UNC 1/8 BSP Indicator for return filter MPS 3-3 (only for option G1-G-F1) VR - VA A/F.14 ER - EC 6 43 A/F.4 Pg 7 7,, ø 4 Indicator for line filter MPS Led.,4,3, Return line filter - Housing pressure drop, Z V N K E Datasheet Reference: HM-19

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN Maximum working pressure 1 bar Flow rates to l/min D e s c r i p t i o n MPS/MST The spin-on filter series is a complete product range suitable, for both

More information

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I.

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I. LMP 900-90 Filter element in according to D 550 Style S Style D.I. D.I. Maximum pressure 30 bar F l o w r a t e s t o 0 0 0 l / m i n 6 Technical data Filter housing (Materials) Head: nodised luminium

More information

SPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER

SPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER PM Pressure Filters MEDIUM PREURE INLINE FILTER Pressure Filters PM PM MPa (0 bar) Port sizes: 1/ 1 Flow rates: 10 l/min TECHNICAL DATA Max. working pressure: MPa (0 bar) Max. test pressure: MPa (0 bar)

More information

Spin-On Filters SSF 24,25

Spin-On Filters SSF 24,25 Spin-On Filters SSF,5 Technical Specification Construction Die cast aluminium head Seals NBR (Buna-N ) Port connections Flow rate Working pressure Operating temperature By-pass valve Clogging indicators

More information

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min Pressure Filters D D 6 In-line mounting Operating pressure up to 1 bar Nominal flow rate up to 9 l/min Description Application In the pressure circuits of hydraulic and lubrication systems. Performance

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to: LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are

More information

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21 Desiccant Air Breathers DBE Section 3: SCHROEDER INDUSTRIES ACCESSORIES 21 Reservoir Accessories A hydraulic systems reservoir can play a significant role in the ingression of contamination into the system.

More information

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min Return Filters E E E 6 E 6 E 7 Tank mounting Nominal flow rate up to 8 l/min Description Application In the return line circuits of hydraulic systems. Performance features Protectionagainst wear: By means

More information

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min Return Filters E E Tank top mounting Connection up to G¼ ominal flow rate up to l/min Description pplication In the return line circuits of hydraulic systems. Performance features Protection against wear:

More information

LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n

LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n LMP Maximum pressure 8 bar F l o w r a t e s t o 6 l / m i n Technical data Filter housing (Materials) Head: luminium Housing: ataphoresis Painting ypass valve: rass - luminium Pressure LMP length: - -

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:

More information

Change-Over Pressure Filter DFDK

Change-Over Pressure Filter DFDK Change-Over Pressure Filter up to 8 l/min, up to 35 bar 3 6 4 6 4 8 33 5 66.x 66.x 99.x 3.x 3 3.x 64 3.x 396 3.x. TECHNICAL SPECIFICATIONS. FILTER HOUSING Construction The filter housings are designed

More information

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in

More information

Flow rates to 200 l/min

Flow rates to 200 l/min LMP MULTIPORT - - Maximum pressure bar low rates to l/min Technical data ilter housing (Materials) Head: luminium Housing: ataphoresis-painted Steel ypass valve: rass - luminium Pressure Working pressure:

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters Suction fi lters SF 5 series Flow rate up to 8 l/min Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example, for

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm DFDK Series Inline Duplex Filters 4568 psi up to 9 gpm Hydraulic Symbol DFDK QL L Ball Valve A DFDK QT T Ball Valve (sizes 33 or larger) A B B Features The DFDK Filters have a filter head of ductile iron

More information

Principles of Filtration. Filter Elements. High Pressure Filters. Section 4. Tank-Mounted, Return Line and Medium Pressure Filters

Principles of Filtration. Filter Elements. High Pressure Filters. Section 4. Tank-Mounted, Return Line and Medium Pressure Filters Principles of Filtration s High Pressure s Section 4 Tank-, Return Line and Medium Pressure s Water Service s Reservoir Accessories SCHROEDER INDURIES 125 Principles of Filtration s Section 4 Section 4

More information

PLD 03 T A CASAPPA S.p.A.

PLD 03 T A CASAPPA S.p.A. GEAR FLOW DIVIDERS INDEX Section Page GENERAL FEATURES... 3 GENERAL DATA... 5 FLOW EQUALIZER... 6 FLOW DIVIDERS... 8 TYPICAL CIRCUITS... 10 NOTES ABOUT COMPOSITION... 12 PORTS DIMENSIONS.... 14 GROUP DIMENSIONS...

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

HNP-021 Oil Purifier. Description. Specifications. Features. Contact Us:

HNP-021 Oil Purifier. Description. Specifications. Features. Contact Us: HNP-021 Oil Purifier Contact Us: www.pall.com/contact Description The HNP-021 has been developed as a conditioner for hydraulic, lubrication and dielectric oils. It removes free and dissolved water, dirt,

More information

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC Publ. 1 - EN0709 - A 01 / 2000 / 2500 / FB Replaces : 1 - EN 084 - B L25-10709 - 1 CONTENTS GENERAL CHARACTERISTICS T67GB T6GC - T6ZC T67GB

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

Tank-Mounted Suction Filter

Tank-Mounted Suction Filter Tank- Suction 20 gpm 75 L/min 6.25 MAX. (159) OPTIONAL DI ALARM OR ELECTRIC SWITCH 4.06 MAX. (103) 1.88 (48).12 (3) THICK GASKET 5.06 (129) Ø HOLE TANK FOR ALLATION 6.38 PO TO PO (162) 45 TYP.44 (11) Ø

More information

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. DIRECTIONAL VALVES CV08-20 Check Valve DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. OPERATION The CV08-20 allows flow passage from 1 to 2,

More information

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI GP1 & GP2 Electropneumatic Regulators FOR PRESSURE CONTROL TO 1, PSI GP1 & GP2 Functional Description The GP series control valve is an electronic pressure regulator designed to precisely control the pressure

More information

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES 52 000/110 ED This series of modular subplates has been designed to make hydraulic circuits and can be used directly on power packs or on any other section of the machine. The subplates are assembled by

More information

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar single stage pumps M/5811 Very high induced air capacity % lower air consumption than comparable single stage units No wearing parts Compatible with a wide range of line contaminants llows direct connection

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

VALVES ISO 5599/1, SERIES IPV-ISV

VALVES ISO 5599/1, SERIES IPV-ISV VALVES ISO 99/1, SERIES IPV-ISV The assembly surface dimensions of ISO1 and ISO2 valves are to ISO99-1. They are available in the -way versions with 2 and 3 positions and with pneumatic or solenoid actuation.

More information

FILTRATION TECHNOLOGY STAUFF. Spin On Filters. Quality and Service Worldwide

FILTRATION TECHNOLOGY STAUFF. Spin On Filters. Quality and Service Worldwide FILTRATION TECHNOLOGY 2 STAUFF Spin On Filters Quality and Service Worldwide Spin-On Filters Australia Stauff Corporation (Pty.) Ltd. P.O.Box 227, 2-2 Doyle Avenue, Unanderra Wollongong, N.S.W 252 AUSTRALIA

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

Schroeder Check Test Point System

Schroeder Check Test Point System Perforated polyamide / kevlar hose, 2 mm ID, 5 mm OD, plastic dust cap. L in (mm) P (max) psi (bar) 6 (150) 10,000 (680) 12 (300) 10,000 (680) 24 (610) 10,000 (680) 36 (915) 10,000 (680) 48 (1220) 10,000

More information

PRESSURE COMPENSATORS TECNORD

PRESSURE COMPENSATORS TECNORD PRESSURE COMPENSATORS 2-way, Compensating / Reducing Valves GPM PSI LPM BAR MODEL CAVITY PAGE 8 3500 30 245 DF-CP2 7/8 14 UNF 60 16 3500 60 245 QC-CP2 Special 62 Typical Schematic Typical application for

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated

More information

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid INTERNATIONAL STANDARD ISO 23181 First edition 2007-08-15 Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid Transmissions hydrauliques Éléments

More information

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar. 00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment

More information

Quality filter cartridges and customized housings.

Quality filter cartridges and customized housings. Single Cartridge & Plastic Housings Multi Cartridge Housings Bag Housings & MicroSentry Bags Jumbo Housings & Cartridges Quality filter cartridges and customized housings. www.shelco.com Stacked Disc Housings

More information

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking: direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting

More information

SUCTION FILTERS. BYPASS VALVE Setting: 30 kpa (0,30 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

SUCTION FILTERS. BYPASS VALVE Setting: 30 kpa (0,30 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C COMPONNTS SUCTION ILTRS S MATRIALS Head: Aluiniu alloy Spinon cartridge: Steel ypass valve: Polyaide Seals: NR Nitrile (KM on request fl uoroelastoer) Indicator housing: rass APPLICATION XAMPL PRSSUR (ISO

More information

Pneumatic valve islands

Pneumatic valve islands Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented

More information

Diaphragm pressure switches, 42 V

Diaphragm pressure switches, 42 V 0166 Diaphragm pressure switches, 42 V Zinc-plated steel body With push-on terminals Overpressure safe to 300 bar *) 0166 Diaphragm pressure switches Adjustment range Thread Normally open (no) : Normally

More information

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B

KEYSTONE. A C E C O E n v i r o n m e n t a l C o m p a n y. Bulletin 10-B KEYSTONE Filtration Solutions A C E C O E n v i r o n m e n t a l C o m p a n y Bulletin 10-B Standard Housings The 11N, 21N and 23N filter housings are tested and certified by NSF International under

More information

Pressure-Relief Cartridge Valve, Size 4

Pressure-Relief Cartridge Valve, Size 4 Pressure-Relief Cartridge Valve, Size 4 Q max = 30 l/min, p max = 420 bar Seated design, direct acting, with mechanical operation Compact construction for cavity type AL 3/4-16 UNF High flow rates 7 pressure

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW ILTRS YRAULI IVISIO TAK AR - Return filters R TIAL ATA ORRIG A OPTIOS ART LOGGIG IIATORS PRSSUR ROP ( p) URVS ROSS UTIOAL VI SPAR PARTS ORRIG IORMATIO IMSIOS O T ILTR LMT ILTRS YRAULI IVISIO R TAK AR RTUR

More information

Bladder Accumulators High pressure

Bladder Accumulators High pressure Bladder Accumulators High pressure 1. DESCRIPTION 1.1. FUNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas (nitrogen) is utilised in

More information

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries HYDRAULIC APPLICATION Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries Special vehicles Plastic and rubber machinery etc. CONTENTS Specification

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

OFFICINE OROBICHE S.p.A. 1/9

OFFICINE OROBICHE S.p.A. 1/9 OFFICINE OROBICHE S.p.A. 1/9 INSTRUCTIONS MANUAL FOR LEVEL SWITCHES SERIES 7000 mod. 7250 AND 7400 Electric 1. INSTRUMENT DESCRIPTION Series 7000 level switches have been designed for external lateral

More information

Series BLK Oil - air cooler

Series BLK Oil - air cooler Series BLK Oil - air cooler maintenance friendly design broad performance range compact dimensions rugged cooling matrix low noise emissions comprehensive accessories DE 35 0001 04/2004 Bühler Meß- und

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety

More information

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application: MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators HYDAC Diaphragm Accumulators Index Page 1. Description 3 Introduction 3 Construction 3 2. Applications 4 3. Technical Data 6 Operation 6 Technical Specifications 6 Temperature Effect

More information

D62 - D63 Directional Control Valve l/min

D62 - D63 Directional Control Valve l/min D62 - D63 Table of Contents 1 1.1 1.2 Product Description... 2 Function... 2 Properties... 2 2 Technical Data... 3 3 3.1 3.2 Ordering Information... 4 Type code... 4 Versions currently available... 4 4

More information

Cover headline. Cover subheadline. Check Valves

Cover headline. Cover subheadline. Check Valves Check Valves Cover headline Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Cover subheadline EATON Screw-In Cartridge Valves E-VLSC-MC-E December

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

directional control valve series cv691

directional control valve series cv691 directional control valve series cv691 Contents Page 3 Page 4 Page 5 Page 6-7 Page 8 Page 9 Page 10 Page 11-12 General Information Technical Data Performance Curves Dimensions Relief Valve Advantages

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

hyprofiltration.com/fsw

hyprofiltration.com/fsw A compact, dedicated off-line contamination solution ideal for small reservoirs, gearboxes and diesel engine crankcase conditioning. Element media options for every application including particulate removal,

More information

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary

More information

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request www.atos.com Table TA60obs/E Axial piston pumps type PVPY- (-R, -) variable displacement, with mechanical controls obsolete components - availability on request PVPY are variable displacement axial piston

More information

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

BUTTERFLY VALVES. Toll Free (877) - ICFLUID  -2- BUTTERFLY VALVES 1. General HyrdoWer is a globally recognized manufacturer of power unit accessories. They have become specialists in the design of Butterfly Valves and Hydraulic Compensators. The shut

More information

SDM to 8 sections monoblock valve D1WWDA02A

SDM to 8 sections monoblock valve D1WWDA02A SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

SEALED CONNECTORS FOR THE LIMIT SWITCHES

SEALED CONNECTORS FOR THE LIMIT SWITCHES SEALED CONNECTORS FOR THE LIMIT SWITCHES LIST OF MODELS / Sealed connectors are used at the cable-connecting section of limit switches. Type and appearance Materials Features Target market Applications

More information

Diaphragm Accumulators

Diaphragm Accumulators Diaphragm Accumulators. DESCRIPTION.. FNCTION Fluids are practically incompressible and cannot therefore store pressure energy. The compressibility of a gas is utilised in HYDAC diaphragm accumulators

More information

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6 Úprava stlačeného vzduchu EWO VMA List of Contents System description Individual Units Pre-Filters 3 Micro-Filters 4 Activated-Charcoal-Filters 5 Combinations 6 Accessories and Main spare parts 6 Service

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is

More information

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK CONTINENTAL HYDRAULICS F05MSV-N* FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400

More information

Pilot valves for pilot operated servo valves

Pilot valves for pilot operated servo valves Data sheet Pilot valves for pilot operated servo valves The range of pilot valves consists of: Constant-pressure pilot valve, type CVP (LP) and CVP (HP) Differential-pressure pilot valve, type CVPP (LP)

More information

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm

Single and double acting, magnetic, self-centering Bores: ø 16, 20, 25, 32, 40 mm > Series CGPT self-centering parallel grippers with T-guide Series CGPT self-centering parallel grippers with T-guide Single and double acting, magnetic, self-centering Bores: ø 6, 20, 25, 32, 40 mm New

More information

Monoblock Directional Control Valve RMB 202

Monoblock Directional Control Valve RMB 202 Monoblock Directional Control Valve RMB 202 Key valve features RMB 202 is a 2-section mono block valve, especially designed for front-end loaders. The valve is prepared for quick connecting couplings,

More information

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US

More information

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP 00134428 Type Miniature compact injector Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / +0 C Working pressure min./max. 2. bar / 6 bar Medium Compressed air Max. particle

More information

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES PRESSURE REGULATORS ALL MEDICAL GASES In this section we propose our pressure regulators (FM series, MU and MERCURY ) and our Rs flowmeters for applications other than oxygen therapy (presented in the

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed ir Cleaning Filter Series M /FF Series For Water Droplet, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the

More information

BS ml Bottle Sampling Unit

BS ml Bottle Sampling Unit BS500 500ml Bottle Sampling Unit User Guide www.mpfiltri.co.uk 200.307-EN Covers Model Numbers BS500 SAFETY WARNING Hydraulic systems contain dangerous fluids at high pressures and temperatures. Installation,

More information

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2 FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel L Compact /, High Flow / - / Air service equipment Series FEATURES Stainless Steel filter, regulator and filter regulator intended for corrosive environment

More information