trafo_011_a_1_cat Bar or cable-through Multiple applications per: - cables: Ø 17 to Ø 100 mm, - bars: 20 x 5 mm to 2 x 125 x 10 mm.
|
|
- Andrew Neal
- 6 years ago
- Views:
Transcription
1 Current transformers Measurement devices trafo_012_a_1_cat trafo_077_b_1_cat trafo_010_a_1_cat trafo_008_a_1_cat trafo_011_a_1_cat Functions SOCOMEC current transformers deliver to the secondary a standard current proportional to the primary current and adapted to the rating of the associated device. They are equipped as standard with removable terminal covers, double terminals allowing the secondary to be short-circuited without any ris. They are mounted using two screw-on metal bracets or, in certain cases, by a clip-on DN rail fastening. The connections are made by screws or by fast-on terminals. Accuracy class: 0.5. Accuracy class: 1 or 3 for higher required powers. Dielectric quality: 3 V - 50 Hz - 1 mn. Operating frequency: Hz. Permanent overload: 1.2 n. Conformity to standards EC 185 (EC 44-1) VDE 0414 Abbreviated description Primary wound moulder case transformer: TRB xxx (xxx = CT width). Cable-through transformer: TCA xx (xx = cable diameter). Bar or cable-through transformer: TCB xx-yy (xx = cable diameter, yy = bar width). Bar-through transformer: TBA yy (yy = bar width). Sectioned split-core transformer: TO xx-yy (xx = inside width, yy = inside height). Other products available Accuracy class: 0.2 S. 1 A secondary. Frequency 400 Hz. Double or triple primary ratio. Summation. Voltage transformer. The range trafo_013_a_1_x_cat trafo_014_a_1_x_cat trafo_015_a_1_x_cat Coiled primary Low primary current. Wide power range available. Primary and secondary connection on CT. Bar or cable-through Multiple applications per: - cables: Ø 17 to Ø 100 mm, - bars: 20 x 5 mm to 2 x 125 x 10 mm. Sectioned split-core transformer Avoid power supply disconnections. Modify an installation. Wide range of openings: 20 x 30 to 160 x 80 mm. B. 12
2 Current transformers References Primary TC toprimaire wound bobiné moulded case CT Cable-through CT trafo_076_a_2_cat trafo_076_a_1_cat trafo_017_a_1_cat trafo_018_a_1_cat trafo_018_a_2_cat TRB 60 TRB 70 TRB 135 TCA 21 TCA 22 Primary CT Secondary References HT References HT References HT 5 A 5 A 192T T A 5 A 192T T A 5 A 192T T A 5 A 192T T A 5 A 192T T ,00 30 A 5 A 192T T ,00 40 A 5 A 192T T ,00 50 A 5 A 192T ,00 60 A 5 A 192T ,00 75 A 5 A 192T , A 5 A 192T , A 5 A 192T A 5 A 192T A 5 A 250 A 5 A 300 A 5 A 400 A 5 A 500 A 5 A 600 A 5 A DN rail mounting 192T ,76 192T ,76 Sealed cover 192T ,40 192T ,40 192T ,40 References HT References HT 192T ,60 192T ,60 192T ,60 192T ,70 192T ,40 192T ,70 192T ,40 192T ,70 192T , A 5 A 192T ,70 31,40 Accessories 192T ,70 192T ,40 192T ,70 192T ,40 192T ,70 192T ,40 192T ,70 192T ,70 192T ,70 192T ,76 192T ,76 no no Plug-in transducer trafo_074_a_2_cat Power supply Output References HT References Self supplied 0-20 ma / 0-10 VDC 192Y ,00 192Y , C 0-20 ma / 0-10 VDC 192Y ,00 192Y ,00 24 VDC 0-20 ma / 0-10 VDC 192Y ,00 192Y ,00 trafo_064_a_1_cat CEA- for TRB 60 CEA- for TRB 70 HT CEA-4 for TRB 60 CEA-4 for TRB 70 Power supply Output References HT References 230 C 4-20 ma / 0-10 VDC 192Y ,00 192Y VDC 4-20 ma / 0-10 VDC 192Y ,00 192Y 0165 HT 334,00 334,00 B. 13
3 Current transformers Measurement devices References Bar or cable-through CT trafo_019_a_2_cat trafo_020_a_1_cat trafo_021_a_2_cat trafo_011_a_2_cat trafo_020_a_2_cat TCB TCB TCB TCB TCB Primary CT Secondary References HT References HT References HT References HT References HT 50 A 5 A 192T ,80 192T ,30 192T ,10 60 A 5 A 192T ,20 192T ,80 192T ,30 192T ,10 75 A 5 A 192T ,20 192T ,80 192T ,30 192T , A 5 A 192T ,20 192T ,80 192T ,30 192T T , A 5 A 192T ,20 192T ,80 192T ,30 192T T , A 5 A 192T ,20 192T ,80 192T ,30 192T T , A 5 A 192T ,20 29,80 38,30 192T , A 5 A 192T ,20 192T ,80 192T ,30 192T T , A 5 A 192T ,20 192T ,40 192T ,30 192T T , A 5 A 192T ,20 192T ,40 192T ,30 192T ,30 192T A 5 A 192T ,20 192T ,70 192T T ,30 192T A 5 A 192T ,70 192T T ,30 192T A 5 A 192T ,70 192T T ,30 192T A 5 A 192T ,00 192T T , A 5 A 192T T , A 5 A 192T ,60 Accessoires DN rail mounting 192T ,00 192T ,76 no 192T ,00 192T ,76 Sealed cover no 192T ,40 no 192T ,40 192T ,40 Plug-in transducer trafo_074_a_2_cat trafo_064_a_1_cat trafo_064_a_1_cat CEA- for TCB CEA- for TCB CEA- for TCB Power supply Output References HT References HT References HT Self supplied 0-20 ma / 0-10 VDC 192Y ,00 192Y ,00 192Y , C 0-20 ma / 0-10 VDC 192Y ,00 192Y ,00 192Y ,00 24 VDC 0-20 ma / 0-10 VDC 192Y ,00 192Y ,00 192Y ,00 CEA-4 for TCB CEA-4 for TCB CEA-4 for TCB Power supply Output References HT References HT References HT 230 C 4-20 ma / 0-10 VDC 192Y ,00 192Y ,00 192Y ,00 24 VDC 4-20 ma / 0-10 VDC 192Y ,00 192Y ,00 192Y ,00 B. 14
4 Current transformers References Bar or cable-through CT Plug-in transducer trafo_074_a_2_cat trafo_023_a_2_cat trafo_024_a_2_cat trafo_025_a_2_cat trafo_026_a_2_cat trafo_026_a_2_cat TCB TCB TCB TCB TCB Primary CT Secondary References HT References HT References HT References HT References HT 100 A 5 A 192T , A 5 A 192T , A 5 A 192T ,30 192T , A 5 A 192T ,30 192T , A 5 A 192T ,30 192T , A 5 A 192T ,30 192T ,30 192T , A 5 A 192T ,20 192T ,90 192T , A 5 A 192T ,20 192T ,90 192T , A 5 A 192T ,90 192T ,20 192T ,80 192T A 5 A 192T ,90 192T ,20 192T ,80 192T A 5 A 192T ,90 192T ,20 192T ,80 192T T , A 5 A 192T T ,30 192T ,10 192T ,00 192T , A 5 A 192T T ,30 192T ,10 192T ,00 192T , A 5 A 192T 64 90,30 192T 81 82,10 192T ,00 192T 175, A 5 A 192T ,30 192T ,10 192T ,00 175, A 5 A 192T T ,00 192T , A 5 A 192T ,00 192T , A 5 A 192T ,00 192T , A 5 A 192T ,00 Accessories Sealed cover 192T ,40 192T ,40 192T ,40 192T ,80 192T ,80 trafo_064_a_1_cat CEA- for TCB CEA- for TCB Power supply Output References HT References HT Autoalimenté 0-20 ma / 0-10 VDC 192Y ,00 192Y , C 0-20 ma / 0-10 VDC 192Y ,00 192Y ,00 24 VDC 0-20 ma / 0-10 VDC 192Y ,00 192Y ,00 CEA-4 for TCB CEA-4 for TCB Power supply Output References HT References HT 230 C 4-20 ma / 0-10 VDC 192Y ,00 192Y ,00 24 VDC 4-20 ma / 0-10 VDC 192Y ,00 192Y ,00 B. 15
5 Current transformers Measurement devices References Bar-through CT trafo_027_a_2_cat trafo_028_a_2_cat trafo_012_a_2_cat trafo_012_a_2_cat TBA 60 TBA 100 TBA 103 TBA 127 Primary CT Secondary References HT References HT References HT References HT 200 A 5 A 192T , A 5 A 192T , A 5 A 192T , A 5 A 192T ,70 192T T , A 5 A 192T ,70 192T T , A 5 A 192T ,70 192T ,00 192T T A 5 A 192T ,40 192T ,00 192T T A 5 A 192T ,40 192T ,00 192T ,70 192T A 5 A 192T ,40 192T ,00 192T ,90 192T , A 5 A 192T ,00 192T ,00 192T ,90 192T , A 5 A 192T ,00 192T ,00 192T ,00 192T , A 5 A 192T ,00 192T ,00 192T ,00 192T , A 5 A 192T ,00 192T ,00 192T ,00 192T , A 5 A 192T ,00 192T ,00 192T ,00 192T , A 5 A 192T ,00 192T , A 5 A 192T ,00 182T 9798 (2) 167, A 5 A 192T 8099 (1) 192,00 182T 9799 (2) 167,00 (1) The dimensions are different for model TBA 100 to 4000 A primary. (2) Replacement model TRA 127 for this rating. Accessories Sealed cover 192T ,40 192T ,40 192T ,40 192T ,40 Summation TC sommateur CT trafo_067_a_2_cat BSA 02 BSA 03 BSA 04 Primary CT Secondary Reference HT Reference HT Reference HT / 5 A 5 A 192T , / 5 A 5 A 192T , / 5 A 5 A 192T ,00 B. 16
6 Current transformers References Three-phase CT DN rail mounted trafo_008_a_2_cat Primary Secondary (1) Operating frequency Max. operating voltage Number of modules References HT 3 x 50 A 5 A Hz C 6 192T ,70 3 x 60 A 5 A Hz C 6 192T ,70 3 x 75 A 5 A Hz C 6 192T ,70 3 x 80 A 5 A Hz C 6 192T ,70 3 x 100 A 5 A Hz C 6 192T ,70 3 x 125 A 5 A Hz C 6 192T ,70 3 x 150 A 5 A Hz C 6 192T ,70 3 x 160 A 5 A Hz C 6 192T ,70 (1) 1 A secondary: on request. TCA 13-3P Split TC ouvrable core CT trafo_079_b_1_cat trafo_077_b_2_cat trafo_080_b_1_cat trafo_081_b_1_cat TO 23 TO 58 TO 812 TO 816 Primary CT Secondary References HT References HT References HT References HT 100 A 5 A 192T , A 5 A 192T , A 5 A 192T , A 5 A 192T ,00 192T ,00 192T , A 5 A 192T ,00 192T ,00 192T , A 5 A 192T ,00 192T ,00 192T , A 5 A 192T ,00 192T , A 5 A 192T ,00 192T , A 5 A 192T ,00 192T , A 5 A 192T ,00 192T , A 5 A 192T ,00 192T ,00 192T , A 5 A 192T ,00 192T , A 5 A 192T ,00 192T , A 5 A 192T , A 5 A 192T , A 5 A 192T , A 5 A 192T , A 5 A 192T ,00 B. 17
7 Electrical measurement Current transformers Electrical characteristics Primary TC toprimaire wound bobiné moulded case CT Primary TRB 60 TRB 70 TRB A A A A A A A A 60 A 75 A 100 A 125 A 150 A Bar or cable-through CT Measurement devices TCA A A A A A A A A A 1200 A 1250 A 1500 A Converter (type) DN rail mounted yes yes yes yes Bar (mm) 20x5 30x10 30x10 40x10 40x10 Ø cable (mm) HxWxD (mm) 65x49.5x x61x48 70x49.9x x61x x71x58 Cable-through CT 50x x86x58 TCA A A A A A A A Converter (type) 1 2 DN rail mounted yes yes yes yes Ø cable (mm) HxWxD (mm) 78.5x61x x71x45 85x135x60 65x45x30 65x49.5x35 Primary TCB TCB TCB TCB TCB TCB TCB A A A A A A A x x96x58 B. 18
8 Current transformers Electrical characteristics Bar TC tobarre or cable-through câble passants. CT Primary TCB TCB TCB TBA 60 TBA 100 TBA 103 TBA A 250 A 300 A 400 A A A A A A A 1250 A 1500 A Bar-through CT A A A A A Converter (type) 3 Bar (mm) 80x10 2x100x10 2x120x10 60x30 100x30 100x35 125x35 HxWxD (mm) 126.5x120x x172x x172x52 132x88x78 170x129x78 (1) 150x99x55 175x100x55 (1) TBA 100 to 4000 A primary: 217x129x78mm. Summation TC ouvrablect Please consult us. Three-phase TC ouvrable CT DN rail mounted Please consult us. Split TC ouvrable core CT Primary TO 23 TO 58 TO 812 TO A A A A A A A A A A A A A A A A A A HxWxD (mm) 106 x 93 x x 125 x x 155 x x 1 x 79 B. 19
9 Current transformers Measurement devices Dimensions Primary TC tobarre wound câble moulded passants case CT TRB 60 TRB 70 TRB K L K L l K L 5 trafo_036_a_1_x_cat trafo_038_a_1_x_cat trafo_037_a_1_x_cat Cable-through CT to 100 A: M8x to 150 A: M10x30 TCA 21 TCA trafo_039_a_1_x_cat ø trafo_042_a_1_x_cat ø Bar or cable-through CT TCB TCB TCB TCB trafo_041_a_1_x_cat ø 17.5 trafo_044_a_1_x_cat ø trafo_045_a_1_x_cat ø trafo_055_b_1_x_cat ø TCB TCB TCB trafo_040_a_1_x_cat ø trafo_043_a_1_x_cat ø 44 K P trafo_046_a_1_x_cat ø 44 K P B. 20
10 Current transformers Dimensions Bar or cable-through CT TCB TCB TCB trafo_048_a_1_x_cat ø 55 K P trafo_047_a_1_x_cat ø 85 -P trafo_049_a_1_x_cat Ø 100 -P Bar-through TC toprimaire CTbobiné TBA 60 TBA to 3000 A TBA A trafo_050_a_1_x_cat P trafo_059_a_1_x_cat P1 100, trafo_082_a_1_x_cat P , TBA 103 TBA 127 S2 S1 trafo_054_a_1_x_cat L P trafo_052_a_1_x_cat B. 21
11 Current transformers Measurement devices Dimensions Plug-in TC toprimaire transducer bobiné trafo_074_a_1_cat Transducer to be associated with adapted current transformers: - input: 1 or 5 A. - output: 0-20 ma, 0-10 V (type CEA-), 4-20 ma, 0-10 V (type CEA-4). - self-supplied or auxiliary power supply 24 VDC or 230 C. - 3 sizes according to the CT: type 1, 2 or 3. trafo_060_a_1_x_cat l U H A A U A + - trafo_071_a_1_gb_cat H W D Dimensions (mm) Type 1 TRB 60, TCB 26-30, TCB Type 2 TRB 70, TCB Type 3 TCB 44-63, TCB H W D Summation TC tobarre passante CT BSA 02 - BSA 03 BSA trafo_073_a_1_x_cat trafo_069_a_1_x_cat B. 22
12 Current transformers Dimensions Three-phase CT DN rail mounted W 7 K/P2 K/P2 K/P2 K K K 58,2 44 Number of modules Front protection rating Terminal bloc protection rating W (mm) Mounting 6 P65 P mm DN rail Split TC ouvrable core CT trafo_078_b_1_gb_cat trafo_009_a_1_gb_cat K/P1 K/P1 K/P1 13,5 H W A B D Dimensions (mm) Type A B H W TO TO TO TO D Fixed by M5 new B. 23
Current transformers. Measurement devices. 2 General Catalogue SOCOMEC. Measurement devices NEW. ÂÂEnergy efficiency
NEW trafo_108_a_1_cat Three-phase CT trafo_010_a_1_cat trafo_077_b_1_cat trafo_012_a_1_cat ÂÂEnergy efficiency 0.2s We offer class 0.2s for your energy efficiency or MD applications. appli_294_a ÂÂFunction
More informationCurrent transformers Measurement devices from 5 to 5000 A
Metering, monitoring & power quality trafo_108_a_1_cat Current transformers Three-phase CT trafo_012_a_1_cat The solution for > ndustry. > Service sector. Strong points trafo_077_b_1_cat trafo_010_a_1_cat
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationPrewired position switches FA series
Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:
More information2/2-Way Solenoid Control Valve
2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital
More informationMANUAL KPS Pressure Control Valve
TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006
More information2/2-way proportional valve
2/2-way proportional valve High sensitivity Type can be combined with 0... 16 bar DN 0.8... 4 mm 1/8, 1/4 or sub-base EEx approvals optional Type 8605 Digital control electronics Cable plug version Type
More informationInductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm
Inductive Linear Displacement Transducers Model IW 260 Measuring strokes 80, 170, 240, 360 Document no. IW 100 HE Date 1.07.201 Contactless, robust sensor system Infinite resolution, no hysteresis Calibrated
More informationSonoMeter 30 Energy Meters
Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationIP65 Air Differential Pressure Switch
Page 1 of 5 PA-DPS-9x IP65 Air Differential Pressure Switch Features: Benefits: Close switching differential IP65 Housing Duct fixing kit included Switching point easily adjusted with scale in One screw
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationThe accuracy and safety of the connected measuring devices are directly regulated. of the introduced current transformers.
Product family Current transformers Current transformers (CTs) are introduced where it is difficult to access a direct measuring ot network current. Current transformer transforms the high network current
More information2/2-way proportional valve
2/2-way proportional valve General purpose 0... 12 bar DN 0.8... 2.0 mm 1/8 or sub-base version Type 2824 can be combined with Type 805 Digital control electronics DIN-rail version Type 07 Cable plug Typ
More informationAir Differentail Pressure Switch
Page 1 of 5 PA-DPS-8x Air Differentail Pressure Switch Features: Benefits: Close switching differential Duct fixing kit included Switching point easily adjusted with scale in Pascals Conduit entry can
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More information2/2-Way Solenoid Control Valve
2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm ort connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital
More information3M Telecommunications Solutions for Networks. Quante QSA (= LSA plus) System Catalogue. Innovation
3M Telecommunications Solutions for Networks Quante QSA (= LSA plus) System Catalogue Innovation IDC Modules Overview 3M Quante Cross Connect System QSA QSA Series 1 Connection modules for screw fixing
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1
ATH 500 M Compact integrated drive Installation in any orientation Water or air cooled CE marked and ROHS compliant Heated version (MT) available for corrosive applicaitons. Pumping speed N 2 He H 2 Ar
More informationPrewired position switches FA series
2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45
More informationHydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN
Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure
More informationVLT 2000 Series. How to size your VLT
Selection of frequency converter Usually the size of frequency converter is chosen on the basis of the shaft output, as this may be the only value known. However, if the data are known for both the application,
More informationMiniature controls. Contactors. Overload relays. Starters. Control relays
Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power
More informationGRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide
GRUNDFOS alldos product information Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide Construction and function Modular system Vacuum regulator for direct mounting
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More informationReferences 6 k thermal overload relays, adjustable from 0.11 to 16 A
s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure
More informationPosition switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
More informationTABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES
TABLE OF CONTENTS 2 TALAS DRYER 4 TALAS MEASURER 7 TALAS PORTABLE DRYER 9 TALAS LEAKER 11 TALAS STARTER 14 TALAS AUXILIARY 17 APPENDICES ALL PICTURES SHOWN ARE FOR REFERENCE ONLY ACTUAL PRODUCT MAY VARY
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic
More informationLEVEL Transmitters. ) of the liquid column above it and the atmospheric pressure (P atm
Hydrostatic level transmitters nivopress N GENERAL DESCRITION The NIVORESS N hydrostatic level transmitters are designed to measure the level of clean or contaminated liquids. The pressure sensor at the
More informationATM.ECO - Analog Pressure Transmitter
Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationEPRB-2 Pressure Transducer
Small size with amplified output Any liquid or gas media compatible with stainless steel Operating temperature up to 150 C (300 F) Variety of pressure ports Available as gage and absolute CE approved DESCRIPTION
More informationRelative and differential pressure module type 698
Relative and differential pressure module type 698-5... 5 mbar / 0... 1 10000 mbar The pressure modules type 698 are suitable for monitoring pressure and flow in air conditioning systems and in the laboratory
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationDifferenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar
692 Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle 0 0.1 25 bar E Technical overview The differential pressure transmitter of type series 692 with
More informationDSB, DSF: Pressure monitors and pressure switches
roduct data sheet 23.760 DSB, DSF: ressure monitors and pressure switches How energy efficiency is improved Control and monitoring according to needs and with no auxiliary energy Features For regulating
More informationGFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features
Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma
More informationATM.ECO/IS - Analog Transmitter with Temperature compensation
Pressure Transmitter - FM / FM-C certified ATM.ECO/IS - Analog Transmitter with Temperature compensation CUSTOMER BENEFITS Certificate: FM, FM-C & IECEx & ATEX Entry level series into precision pressure
More informationClimatic Independent Level Sensor LAR
1 Product Information LAR-361 LAR-761 Climatic Independent Level Sensor LAR Application / Specified usage Authorizations Hydrostatic level measurement in humid ambiance Special applicable for exterior
More informationOPTIBAR P 1010 C Technical Datasheet
Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability
More information3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.
3G Operating instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 01. July 2011/Rev. 0 Operating Instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 1 July 2011 / Rev.
More informationSESI SMD Power Inductors and Transformers
39 SESI SMD Power Inductors and Transformers Microspire upgraded aircoil grid transfer + transfer moulding technology by using PLNR ferrites ; which lead to the SESI product range (SMD Energy Storage Inductors).
More informationCircuit breakers PR 60
Circuit breakers PR series are mechanical switching devices able to switch, conduct and switch-off the current under normal conditions and able to switch, conduct and automatically switch-off the current
More informationATM/GR. Electronic pressure switches CUSTOMER BENEFITS
Electronic pressure switches ATM/GR CUSTOMER BENEFITS Pressure sensor with integrated switching contacts Modular sensor structure (any process and electrical connections can be combined) Manual readjustment
More informationCompact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min
Compact Ejectors Suitability for Industry-Specific Applications Applications Handling of air-tight as well as porous workpieces supply and vacuum monitoring in automated systems For use in sheet metal
More informationG SERIES METRIC MACHINE SCREW ACTUATOR
G SERIES METRIC MACHINE SCREW ACTUATOR kn to 0kN Duff-Norton metric actuators are manufactured to the same high quality standards and include all the same features and benefits as the standard line of
More informationLimit switches OsiSense XC Special For material handling applications, type XC1 AC
Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics
More information2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version
2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for
More informationElectropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765
Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from
More informationOperating instructions Capacitive sensor KIA (M30) / / 2010
Operating instructions Capacitive sensor KIA (M30) UK 704182 / 03 07 / 2010 Contents 1 Preliminary note 3 2 Safety instructions 3 3 Functions and features 3 3.1 Application examples 4 4 Installation 4
More informationJET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE
JET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE i Read the instructions 1. Installation mounting By purchaising the ELEGANCE device, you obtained a high-quality product that will help you to enjoy the
More informationUltrasonic. Continuous level measurement. Overview Page 64 VEGASON series 60 Page 66 AL-EN
Ultrasonic Continuous level measurement Overview Page 64 VEGASON series 60 Page 66 6 VEGASON Non-contact measurement with ultrasonics Measuring principle Short ultrasonic pulses in the range of 5 to 70
More informationATM.1ST. Pressure transmitters CUSTOMER BENEFITS
Pressure transmitters ATM.1ST CUSTOMER BENEFITS High precision pressure sensor over the whole temperature range Electronic compensation Modular sensor structure (any process and electrical connections
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationTeSys protection components
Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively
More informationAlhambra Arabic design, British engineering
Alhambra Arabic design, British engineering A UNIQUE STYLE FOR ANY ENVIRONMENT / 036 / /// Unique inspiration and expertise Inspired by the original decorations of the Alhambra Palace in Granada, Spain,
More informationDigital electro-pneumatic regulators Series ER100
CATALOGUE > Release 8.2 Digital electro-pneumatic regulators Series ER100 TREATMENT > Digital electro-pneumatic regulators Series ER100 Port G1/4» Compact design» Digital display» Analog and digital input»
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationMULTIPOL - VDMA. PNEUMATIC SPOOL VALVE ISLANDS VDMA ISO 02 - ISO 01 (G1/8 - G1/4) designed for connection to a PLC by multiwire cable
P8.G.R PEUATIC SPOOL VALVE ISLADS VDA - ISO - ISO (G/8 - G/) designed for connection to a PLC by multiwire cable ULTIPOL - VDA IPUT IPUT OUTPUT OUTPUT OUTPUT IPUT IPUT ULTIPOL - VDA Pneumatic spool valve
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationInstallation, use and maintenance instructions. Gas burner (5)
Installation, use and maintenance instructions Gas burner MODEL GAS 4 TYPE 516 T80 291 (5) TECHNICAL FEATURES Thermal output 180-470 kw 154.800-404.200 kcal/h Fuel Natural gas Pci 8-10 kwh/m 3 = 7000-8600
More informationOSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide
OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature
More informationInstruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor
Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com
More informationFeatures. RP011 - Compact Multimedia X-Slim Keyboard. Brief Specification Product Dimension: Keyboard:320(L) 160(W) 14.5(H)mm
RP011 - Compact Multimedia X-Slim Keyboard Features X slim keyboard 7 hot keys Brief Specification Product Dimension: Keyboard:320(L) 160(W) 14.5(H)mm Package Includes:.X-Slim Keyboard System Requirements
More informationDo not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.
Installation and Operation Instructions Directional MR6 and MR6MC directional s are bright and versatile warning lights that are suited to a wide variety of applications. Their low profile, narrow shape
More informationPneumatic valve islands
Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented
More informationZelio Relays RSL Slim Interface Plug-In Relays
Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition
Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationFlamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps
Airfix D-E 6442.eps GB Installation and operating instructions 1999, Exclusion of liability All operation and maintenance related technical information, data and instructions contained in these installation
More informationMPRM1690 MPRM2590 MPRM3290
Pinze elettriche radiali a 2 griffe 2-jaw radial electric grippers MPRM 2-jaw radial self-centering electric gripper Plug & play user friendly gripper. No electricity consumption when gripper is engaged.
More information2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure
Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationSonoSelect 10 and SonoSafe 10 energy meters
SonoSelect 10 and SonoSafe 10 energy meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationTransmitter CS 21 Operation Manual
Transmitter CS 21 Operation Manual Content Page For your Safety 3 General Description 3 Detection Principle 4 Operational Notes 4 Design 4 Mounting Position of CS21 5 Mounting 6 Installation of Electrical
More informationAvailable models Devices Color White sealing bellows Black sealing bellows NDT SW NDT GB NDT RT NDT GN NDT WS NDT BL NDT GR
Pushbuttons Left: type series N with sealing bellows, color white (standard). Right: type series N with sealing bellows, color black. Protective collar against unintentional actuation: refer to page 58
More informationMODELS (2 foot Version) (4 foot Version)
INSTALLATION AND MAINTENANCE MANUAL DUROSITE LED LINEAR FIXTURE Document No: 9100-127-2571-99 Rev A April, 2016 MODELS (2 foot Version) (4 foot Version) ALL LAE ALL LBE These instructions contain important
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationATM - Analog Pressure Transmitter
Pressure Transmitter ATM - Analog Pressure Transmitter CUSTOMER BENEFITS Fast customization thanks to configurable product design Demountable electrical connector option to allow adjustment of zero and
More informationOEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE
OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE 1 These instructions generally describe the installation, operation, and maintenance of subject equipment. The manufacturer reserves the right
More informationInstrumentation & Data Acquisition Systems
Instrumentation & Data Acquisition Systems Section 4 - Pressure Robert W. Harrison, PE Bob@TheHarrisonHouse.com Made in USA 1 Definition of Pressure Pressure is the amount of force applied perpendicular
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm
Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationMASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS
MASS FLOW SYSTEMS MASS FLOW MEASURING, CONTROLLING AND BLENDING SYSTEMS Using state-of-the-art measuring and microprocessor technologies, Advanced has assembled a series of systems which can measure mass
More informationOperating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
More informationHERZ-Motorised flow controler
HERZ-Motorised flow controler Control and regulating valve Data sheet 46, Issue 214 Dimensions in mm 4 close dimension 9,35 M DN G H1 H2 H2 + Actuator B1 B2 1 2 M 1 46 11 15 3/4 G 66 59 73 134 49 63 48
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified
Intrinsically safe pressure transmitters ATM/Ex - Intrinsically Safe Analog Pressure Transmitter - ATEX / IECEx Certified CUSTOMER BENEFITS Certificate: ATEX & IECEx Fast customization thanks to configurable
More informationUltrasonic level transmitter and indicator
Ultrasonic level transmitter and indicator No contact with the product Compact design with polycarbonate housing (electronics and display). Remote display available on request Very good resistance in corrosive
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable
More informationOperating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry
Operating Instructions for Intrinsically Safe ressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Contents 1. Introduction 2. Abbreviations, symbols 3. Important
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition
Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.
More informationPressure Transmitters 36 F-27839
Pressure Transmitters 36 F-27839 SPD310/SPD360 Air Differential schneider-electric.com 37 SPD310/SPD360 SPD310/SPD360 differential pressure transmitters are intended for use in air handling systems for
More informationElectronic relative and differential pressure switch type 616
Electronic relative and differential pressure switch type 616 Pressure range 0... 0.1 25 bar The switching points of the pressure switch type 616 can be potentiometer adjusted by the customer, or set in
More information