Library of Set Points for PVIGPS.M. Factory settings for Intelipro PV
|
|
- Christian Boyd
- 5 years ago
- Views:
Transcription
1 Library of Set Points for PVIGPS.M Factory settings for Intelipro PV Set Point Default Range Step Mains CT Ratio [A/5A] 400 1A/5A 25000A/5A A/5A Mains CT Polar Forward Forward Reverse EF CT Ratio [A/5A] 400 1A/5A 8000A/5A A/5A Mains PT Ratio [V/V] 1.0 V/V 0.01 V/V V/V Gen PT Ratio [V/V] 0.1 V/V V/V NomVolts Ph-N [V] 240V 80 V V NomVolts Ph-Ph [V] 416V 80 V V Nominal Freq [Hz] 50 Hz 45 V 65 Hz Nominal Power [kw] 26 kw 0 kw kw NominMainsCurr [A] 63A 0 A A Voltage Setup [Ph To N/Ph To Ph to N Ph To N Ph To Ph Ph] CB1 Prot Timer [s] 0 s 0 s 60 s CB2 Prot Timer [s] 0 s 0 s 60 s Start Trip Enabled DISABLED ENABLED COM1 Mode DIRECT DIRECT/MODEM/ [DIRECT/MODEM/] COM2 Mode DIRECT DIRECT/MODEM/ [DIRECT/MODEM/] ModbusComSpeed bps bps [9600/19200/38400/57600 bps bps] CAN Bus Mode [32C / 8C] 32C 8C 32C DIRECT/MODEM/ DIRECT/MODEM/
2 GENERAL ProtActiv Del [s] 2.0 s 0 s 30 s Backup Trp Del s s Comm Trp Del 0.0 s 0.0 s 20.0 s Comm Trp Len 1.0 s 0.1 s 20.0 s Auto FR DISABLED DISABLED/ ON DEACT/ CB1+CB2=0/ NOFAULT+DEL DISABLED/ ON DEACT/ CB1+CB2=0/ NOFAULT+DEL Auto FR Del [s] 10 s 1 s 3600 s Aux >V [V] 36V Aux <V 40 V Aux <V [V] 18V 8 v Aux >V Aux V Del [s] 1 s 0 s 600 s V <> V> V> Del V>> V>> Del V< V< Del V<< [V] V<< Del [s] RST V 257V 0 v V 5.00 s 0.00 s s 0V 0 v V 0s 0.00 s s 200 V 0 v V 2.50 s 0.00 s s 0V 0 v V 0s 0.00 s s +/- 0% V > +/- 0% V<> +/- 4% V<> AVG V > 255V 1 v V AVG V > Del 15s 1s V Trp BO Trp 1 /Trp 2 / Trp 1 /Trp 2 /
3 V Unb V Unb [%Un] 20% 0% Nom.V 150% Nom.V V < POS 1.0% 0.0% Un 100%Un V > NEG 1.0% 0.0% Un 100%Un V Unb Del [s] 5.00s 0.00 s s RST V +/- 0% +/- 0% V<> +/- 4% V<> V Unb Trp BO [Trp 1/Trp2/Trp 1+2/) PhaseRotation [CW/CCW/ANY] CW CW / CCW / ANY Ph Rot Trp BO CW / CCW / ANY Dyn Volt V Lim 1 V Lim 2 V Lim 3 [% Un] Delay 1 Delay 2 Delay 3 [s] 30% Un 0%Un 100%Un 70% Un 0%Un 100%Un 90% Un 0%Un 100%Un 0.15 s 0.70 s 1.50 s 0.01s 0.01s 0.01s Reset Time [s] 2.00 s 1 DynVoltBlockB1 DynVoltTrpBO Trp 1/Trp 2 Trp 1/Trp 2 /
4 QU V< [%Un] 85% Un 80%Un 90%Un Rst V< [%Un] 95% Un 90%Un 100%Un I Min [%In] 10% In 2%In 20%In Q Min [%S] 5% s <-10.0%S 10.0>%S QU Del 1 [s] 0.50 s 1.00s QU Del 2 [s] 1.50 s 1.00s 2.00s QU BlockBI [Block 1/Block 2/Block 1+2/] QU Trp Gen [Trp 1/Trp 2/Trp 1+2/] QU Trp Mns [Trp 1/Trp 2/Trp 1+2/] f<> f> f>> f< f<< [Hz] f> del f>> del f< del 52.5Hz 0.00Hz 70.00Hz 53 Hz 0.00Hz 70.00Hz 47.5 Hz 0.00Hz 70.00Hz 47 Hz 0.00Hz 70.00Hz s 5.00 s 0.5 s f<< del [s] RST F < 100% f < 100% f< / +0,2% f< / 47,5 Hz RST f > 100% f > 100% f>/ -0,2% f> / 50,05 Hz f Trp BO [Trp 1/Trp 2/Trp 1+2/] 100% f< / +0,2% f< / 47,5 Hz 100% f>/ -0,2% f> / 50,05 Hz
5 LOM Vs Lim [ 0 ] ROCOF [Hz/s] 0.4 Hz/s 0.00Hz 10.00Hz ROCOF filt [-] LOM Init Del [s] 2 s LOM Trip Del [s] 2 s 1s 3 LOM Trp BO [Trp 1/Trp 2/Trp 1+2/] I> Trp 1 / Trp 2 / Trp 1+2 / 200% 0% In 1000%In I> I>> [%In] I> Del I>> [s] I Block BI I Trp BO Trp 1 / Trp 2 / Trp 1+2 / 1 I> V I> V Del [s] 1.0s 0.1s 2 I> V Curve IDMT I> V Trp BO / Trp 1+2 / / Trp 1+2 / I Unb I Unb [%In] 50% 1%In 200%In IMinDiffEval [%In] 0% 0%In 100%In I Unb [s] 5.0 s 0.0s 600s I> V Trip BO / /
6 EFC EFC> Lim [%In] 0% 1%In 300%In EFC> Del [s] 10 s 0.0s EFC> T Lim [%In] 10% 1%In 300%In EFC> T Del [s] 1.0s 0.1s 2 EFC> T Curve IDMT EFC Trp BO / Trp 1+2 / / Trp 1+2 / IGS IGS> Lim [ma] 0 ma 0.0mA 100.0mA IGS> Del [s] 10 s 0.1s 2 IGS> T Lim [ma] 10 ma 0.00mA 50.0mA IGS> T Del [s] 1.0 s 0.1s 2 IGS> T Curve IDMT IGS Trp BO / Trp 1+2 / / Trp 1+2 / NVD NVD> Lim [V] 0V 0v 150 v NVD Del 60 s 0s 300s NVD >> 50V 0v 500 v NDV >> Del 60s 0s 300s RST NVD +/- 0% +/- 0% +/- 4% NVD Trp BO / NVD >> Trp BO /
7 P<> P>,P>> [%Pn] 10.00% -300%Pn 300%Pn P> Del, P>> Del [s] 5.00 s 15 P> Direction, P>> Direction Over Under Over Filter Delay 5s 0s 300s Trp BO Mains Power 1 % Pn 0 0%Pn 100%Pn Mains Power 2 % Pn 0 0%Pn 100%Pn Mains Power 3 % Pn 0 0%Pn 100%Pn Mains Power 4 % Pn 0 0%Pn 100%Pn Mains Power 5 % Pn 0 0%Pn 100%Pn Mains Power 6 % Pn 0 0%Pn 100%Pn Mains Power 7 % Pn 0 0%Pn 100%Pn Mains Power 8 % Pn 0 0%Pn 100%Pn PF Ind PF limit Ind PF Del 1s 0.0s 60.0s Cap PF limit Cap PF Del 1s 0.0s 60.0s PF Trp BO MaxParallTime MaxParallTime [s] 300.0s 0.1s s MaxPT Trp BO Trp 1 / Trp 2 / Trp 1+2 /
DESCRIPTION / REMARKS E40972 ROTATION (2).250 FLAG TYPE Q.C. TERMS. WITH INSUL. GRIP ON BROWN LEADS. LEADS SKINNED.750±.062
Dimensional Drawing MODEL REF CUSTOMER HP VOLTS AMPS HZ RPM ROTATION CUSTOMER PN DESCRIPTION / REMARKS K55HXRHM2147 E40972 DAYTON 1/6 208230 1.3 60 1075 C.CW. LEAD END REV BALL BEARING E40972 #16 GREEN
More informationGNX 20/21. Owner s Manual
GNX 20/21 Owner s Manual Table of Contents Introduction...1 Device Overview... 1 Using the Race Timer... 1 Profiles... 1 Selecting a Profile... 1 Restoring Profiles to their Default Settings... 1 Instrument
More informationT-02b2: Set Up/Adjust Drive (DC Full Range GE-Valutr
Page 1 of 13 T-02b2: Set Up/Adjust Drive (DC Full Range GE-Valutr alutrol) SAFETY FIRST o Follow all Caterpillar facility safety standards when performing this task. o Dangerous voltage levels of AC and
More informationSonoMeter 30 Energy Meters
Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationGNX 20/21. Owner s Manual
GNX 20/21 Owner s Manual March 2016 190-01659-00_0C All rights reserved. Under the copyright laws, this manual may not be copied, in whole or in part, without the written consent of Garmin. Garmin reserves
More informationPage 2 of 46 Prepared by: Engr. Ram Sankar
Page 2 of 46 CHAPTER 1 GETTING STARTED Page 3 of 46 Establishing Communication with Relay: 1. Open MICOM S1 studio and click on NEW SYSTEM. 2. Name it and save on desired location and click on OK. Page
More informationTVS Diodes Axial Leaded 30 kw > 30KPA-HRA series. Features. 30 kw 8.0 W 400 A. -55 to 175 C. Notes: 8.0 C/W
3KPA-HRA Series RoHS Pb e3 Descriptions AGENCY Uni-directional Agency Approvals Maximum Ratings and Thermal Characteristics (T A =25 O C unless otherwise noted) Parameter Symbol Value Unit Peak Pulse Power
More information5KP-HR Series. TVS Diodes Axial Leaded 5 kw > 5KP-HR series. Description. Uni-directional
5KP-HR Series RoHS Pb e3 AGENCY Uni-directional Agency Approvals AGENCY FILE NUMBER E2353 Bi-directional Maximum Ratings and Thermal Characteristics (T A =25 O C unless otherwise noted) Parameter Symbol
More information15KPA-HRA Series. TVS Diodes Axial Leaded 15 kw > 15KPA-HRA series. Descritions
5KPA-HRA Series RoHS Pb e3 Descritions Uni-directional The 5KPA-HRA High Reliability Series is designed specifically to protect sensitive electronic equipment from voltage transients induced by lightning
More informationPushbuttons, Indicating Light, and Rotary Switch Stations Series 4975
Series 4975 Series 4975 Pushbutton Stations are designed for shipboard control applications requiring heavy duty watertight master switches. Stations are available with one, two or three elements equipped
More informationHYDROCHLOR. Salt water pool chlorinator.
HYDROCHLOR Salt water pool chlorinator Ezy Timer Energy Saving Winter Mode Precision Chlorine Production Super Chlorination Function Self Cleaning, Electrolytic Cell Battery Backup 2 www.waterco.com How
More informationCertificate of compliance
Bureau Veritas Consumer Products Services Germany GmbH Businesspark A96 86842 Türkheim Germany + 49 (0) 40 740 41 0 cps-tuerkheim@de.bureauveritas.com Certification body of BV CPS GmbH Accredited according
More informationTR Electronic Pressure Regulator. User s Manual
TR Electronic Pressure Regulator Page 2 of 13 Table of Contents Warnings, Cautions & Notices... 3 Factory Default Setting... 4 Quick Start Procedure... 5 Configuration Tab... 8 Setup Tab... 9 Internal
More informationGNX 20/21 Owner s Manual
GNX 20/21 Owner s Manual February 2014 190-01659-00_0B Printed in Taiwan All rights reserved. Under the copyright laws, this manual may not be copied, in whole or in part, without the written consent of
More informationELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11
ELIMINATOR COMPETITION DRAG RACE Program Manual Firm Ver 4.11 The Portatree Eliminator Super 2000 Competition Track Timer can be used with an IBM Compatible Personal Computer connected through Com Port
More informationAHE58/59 AC Servo System
AHE58/59 AC Servo System HMI-12 User Manual Safely INstruction Please read this manual carefully, also with related manual for the machine head before use. For perfect operation and safety, installing
More informationDesign Envelope Booster. Sequence of operation
Design Envelope Booster Sequence of operation File No: 62.835 Date: february 11, 2015 Supersedes: 62.835 Date: july 11, 2014 sequence of operation Design Envelope Booster 2 general The packaged domestic
More informationRace Screen: Figure 2: Race Screen. Figure 3: Race Screen with Top Bulb Lock
Eliminator Competition Stand Alone Mode - Instruction Manual Main Menu: After startup, the Eliminator Competition will enter the Main Menu. Press the right/left arrow buttons to move through the menu.
More informationSR-242 USER S GUIDE. Table of Contents
User s Guide gfhf Table of Contents 1. Introduction...3 2. Faceplate...3 2.1 Parameter List...3 2.2 Parameter Buttons ( and )...4 2.3 Function Buttons ( and )...4 2.4 LED Status Window...4 2.5 Value Setting
More informationKIT. Small Automatic Water Boosters KIT MODELS
KIT Small Automatic Water Boosters The electronic controller KIT orders the automatic start and stop of the water pump when opening or closing any tap or valve in the installation. There are four main
More informationPIKO IQ 4.2, Plenticore plus 4.2 Rating: 10,0kW 8,5kW 7,0kW 5,5kW 4,2kW Rated voltage: PIKO IQ 8.5, Plenticore plus 8.5
Applicant: Product: Certificate of conformity Generating unit, NS-protection KOSTAL Solar Electric GmbH Hanferstraße 6 79108 Freiburg i. Br. Germany Photovoltaic Inverter with integrated NS-protection
More informationStand-Alone Bubble Detection System
Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When
More informationClub logins into My Swim Results can maintain the Club portion of the club fees through the Membership Fees Setup.
Membership Fees Club logins into My Swim Results can maintain the Club portion of the club fees through the Membership Fees Setup. On the Membership Tab click on Membership Fees Setup. My Swim Results
More informationTOSVERT VF-FS1 series APOGEE FLN option unit Function Manual APG002Z NOTICE
TOSVERT VF-FS1 series APOGEE FLN option unit Function Manual APG002Z NOTICE 1. Make sure that this instruction manual is delivered to the end user of APOGEE FLN option unit. 2. Read this manual before
More informationOld documentation - Only for your information! Product is not available anymore!
Double solenoid valve Regulator and safety combination Infinitely variable floating operation DM-EF 07-7. Printed in Germany Rösler Druck Edition 0.0 Nr. 9 Flanges, pressure switches, line sockets, pulse
More informationCBC2 performance with switched capacitor DC-DC converter. systems meeting, 12/2/14
CBC2 performance with switched capacitor DC-DC converter systems meeting, 12/2/14 1 reminder of results from CBC1 +2.5V GND 1n can power CBC from single +2.5V supply 1uF DC-DC diff. clock (CMOS) 1 MHz
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationCP-8400 AutoSampler and CP-8410 AutoInjector
Varian, Inc. 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA CP-8400 AutoSampler and CP-8410 AutoInjector Operator's Manual Varian, Inc. 2003 Printed in the Netherlands 03-914852-00:Rev. 4.1 Table
More information(A) ±.060 ±.060 (A) NAMEPLATE NAMEPLATE n.004 A TOP TOP CONNECTIONS SLINGER PROTECTOR CONNECTIONS LINE
Dimensional Drawing VAR MODEL CUST. T. NO. A B C D H VOLTS SF AMS HZ RM CONN VOLTS ROT. DESCRITION / REMARKS 00 C55JXKAL58.6 / 5/0.85 6./. 60 450 AUTO 56J,BALL BEARING 00 C55JXKAL58.6 / 5/0.85 6./. 60
More informationRoller AC Servo System
Safely Instruction Roller AC Servo System HMI-15 User Manual Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller
More informationUsers Group Conference 2018
Users Group Conference 2018 Compressor Analysis Special Circumstances Tracy Wimberly Sr. Reciprocating Equipment Analyst, Windrock 1 Topics, top compressor questions Ultrasound Baseline Cat Eyes Leak Index
More informationTFC TM - Touch Force Control
1. How is all the data that is displayed on the touch screen changed or originated? Data is entered or modifi ed using the TFC Data Management Tool which is provided as part of the TFC kit. 2. Can the
More informationTransformer Lifecycle Services. Container Id: Miscellaneous Id: Second Name: Sequence #:
Report # 173396 Sample # 1 Transformer Lifecycle Services Received 08/09/2016 Date August 10, 2016 Serial Number: 100413030004 Substation Name: Colorado Bend Design Type: Core Type Manufacturer: HicoA
More informationAPPLICATION NOTE. OJ-DV Modbus protocol. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS E 03/18 (PDJ) 2018 OJ Electronics A/S
APPLICATION NOTE 67467E 03/18 (PDJ) 2018 OJ Electronics A/S OJ-DV Modbus protocol OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS Introduction This protocol contains the Modbus addresses
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges
More informationMonsoon3V+ Multiple Pump VFD Control System. Please pass these instructions on to the operator of this equipment.
Monsoon3V+ Multiple Pump VFD Control System Please pass these instructions on to the operator of this equipment. INTRODUCTION MONSOON 3V+ Pump Controller The MONSOON 3V+ pump control system is a fully
More informationAPPLICATION NOTES DELOMATIC 4, DM-4 GAS
APPLICATION NOTES DELOMATIC 4, DM-4 GAS Emission control Lambda sensor p/t regulation Combustion chamber temperature regulation Emission control configuration Emission control curve Document no.: 4189340653C
More informationPROCESSOR UNIT - V3 WITH WIRING. Spring limit M180 and ROF 25bb/s
21 st century electronics for AEG weapons PROCESSOR UNIT - V3 WITH WIRING Spring limit M180 and ROF 25bb/s Installation of this device leave to expert He must know how to solder and disassemble airsoft
More informationVerdi G-Series Family
Verdi G-Series Family High-Power Pumps for Ti:Sapphire Lasers and Amplifiers Applications such as ultrafast spectroscopy, multiphoton microscopy, terahertz imaging, and Optical Coherence Tomography (OCT)
More informationEXTREME PROCESSOR UNIT
21 st century electronics for AEG weapons EXTREME PROCESSOR UNIT WITH WIRING GERMANY VERSION (no burst, no fullauto) Spring limit M190 Installation of this device leave to expert He must know how to solder
More informationSTAND alone & p.c. VERSION
STAND alone & p.c. VERSION ECONOMY TRACK SYSTEMS 1/4 & 1/8 Mile Asphalt Track Dirt / Sand Track Mud Track Snowmobile Track R/C Car Track Custom Track Systems Timing to.001 Accuracy Time Slip Printer Optional
More informationD e s c r i p t i o n
MPS Series D e s c r i p t i o n The MPS spin-on filter series is a complete product range suitable, for both suction and return applications. Utilising spin-on canisters, the MPS series are quick and
More informationProto Matrix Musashi 3 Upgrade Manual
Proto Matrix Musashi 3 Upgrade Manual Musashi 3 Upgrade Instructions for Proto Matrix FEATURES...3 LED INDICATOR...3 SOLID GREEN...3 SOLID RED...3 SLOW BLINKING GREEN...3 SLOW BLINKING RED...3 POWER OPERATION...3
More informationCTS-M1816 CARBON MONOXIDE TRANSMITTER/SENSOR
CTS-M1816 CARBON MONOXIDE TRANSMITTER/SENSOR INSTALLATION OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749 RICHMOND, ONTARIO CANADA K0A 2Z0 PHONE: (613) 838-4005
More informationSCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual
SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel DTLS Manual This document contains proprietary information. Copyright 2015 Scientific Data Systems, Inc. All rights reserved. 1 Depth Tension
More informationMONSOON 6V Pump Control System
MONSOON 6V Pump Control System Installation and Operating Instructions Please pass these instructions on to the operator of this equipment. INTRODUCTION MONSOON 6V Pump Controller The MONSOON 6V pump control
More informationUser s manual VCI07. For variable speed compressors ed00. Applicable as of Version 12. Bar PSI C F
User s manual EN VCI07 For variable speed compressors 62 205 930 11 ed00 Applicable as of Version 12 Bar PSI C F Table of contains 1 - GENERAL INFORMATION...3 2 - USER INTERFACE...3 2.1 DISPLAYS...3 2.2
More informationGNX 120/130. Owner s Manual
GNX 120/130 Owner s Manual March 2016 190-01846-00_0B All rights reserved. Under the copyright laws, this manual may not be copied, in whole or in part, without the written consent of Garmin. Garmin reserves
More informationTable of Contents. Sensor Calibration and Troubleshooting CDS4000 CO 2. Introduction 1. Handling Information. Calibration 2.
FANs 216, 1628.3 Technical Bulletin CDS4000 Issue Date 0797 CDS4000 CO 2 Sensor Calibration and Troubleshooting Table of Contents Introduction 1 Handling Information 1 Calibration 2 Preparation 2 Cautions
More informationECL Comfort 110, application 131 (valid as of software version 2.00)
Operating Guide ECL Comfort 110, application 131 (valid as of software version 2.00) English version www.danfoss.com How to navigate? Adjust temperatures and values. Switch between menu lines. Select /
More informationPush Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control
Setup Functions Guide MMTM/PB Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi-way control DIGINET.NET.AU Timer Setup Push Button Minute Timer The LEDsmart + push
More informationGHC 20 Owner s Manual
GHC 20 Owner s Manual Introduction See the Important Safety and Product Information guide in the product box for product warnings and other important information. You are responsible for the safe and prudent
More informationTroubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale
Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale Contents Description Refer To: Scale Troubleshooting Chart Troubleshooting Error Codes Error Messages Adjustments / Repair Procedures
More informationOperating instructions Pressure sensor. PN422x / / 2013
Operating instructions Pressure sensor PN422x 80002606 / 00 11 / 2013 Contents 1 Preliminary note...3 1.1 ymbols used...3 2 afety instructions...3 3 Functions and features...3 4 Function...5 4.1 witching
More informationMaster Control Systems, Inc. Variable Speed Fire Pump Controllers
Master Control Systems, Inc. Variable Speed Fire Pump Controllers Meets NFPA 20-2013 UL/FM Listed and Approved for fire protections 1 Why Variable Speed? Huge Sprinkler System and Standpipe Cost Savings
More informationCP3R Quick Start Manual
RUN MON PRM PU EXT NET RUN D700 3 200V RUN MON PRM PU EXT NET RUN D700 3 200V CP3R Quick Start Manual for Constant Pressure Applications This CP3R Drive has been factory pre-programmed for your specific
More informationCPN1 Quick Start Manual
RUN MON PRM PU EXT NET RUN RUN MON PRM PU EXT NET RUN CPN1 Quick Start Manual for Constant Pressure Applications This CPN1 Drive has been factory pre-programmed for your specific pressure control application.
More informationSensoric 4-20 ma Transmitter Board Operation Manual
Sensoric 4-20 ma Transmitter Board Operation Manual 1 Content Features Operation Manual Technical Data Mechanical Dimensions Remarks & Contact information 2 Features Soldered sensor cell (non replaceable)
More informationCOMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x
Electrical Installation Requirements Care should be taken to separate the power and signal cables to prevent electrical interference and possible damage due to inadvertent connection. SUPPLY E L N LN2
More informationTechnical Bulletin, Communicating with Gas Chromatographs
Last Updated: 13- July-2010 TB-080000C Technical Bulletin, Communicating with Gas Chromatographs OMNI FLOW COMPUTERS, INC. 12620 West Airport Boulevard, Suite 100 Sugar Land, Texas 77478 United States
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional
More informationName / Function FSUIPC
Fly The Maddog variables IOCP 1 Batt On 69833 2786 switch 20 APU run 69831 2770 30 APU start switch 40 APU Air Off 69830 2781 switch 50 APU Air On 60 APU Air Colder switch 70 APU Dors Auto 69832 2788 switch
More informationOwner s Manual Humiport 10/20
4201 Lien Rd Madison, WI 53704 Owner s Manual Humiport 10/20 Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix Humiport line of ThermoHygrometers offers the restoration
More informationEXTREME PROCESSOR UNIT
21 st century electronics for AEG weapons EXTREME PROCESSOR UNIT Spring limit M190 Installation of this device leave to expert He must know how to solder and disassemble airsoft gun Never use soldering
More information955730_1 4/17/18. FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays
955730_1 4/17/18 FlowSense Operator s Guide For Gen2 20/20 SeedSense Displays Contents System Setup and Operation...3 Configuring Monitor for FlowSense...3 FlowSense Setup...4 Liquid Alerts...8 Monitoring
More informationBI-680 Online Dissolved Oxygen Controller Instruction Manual
BI-680 Online Dissolved Oxygen Controller Instruction Manual BANTE INSTRUMENTS CO., LTD BI-680 Online Dissolved Oxygen Controller 1 Introduction Thank you for selecting the BI-680 online dissolved oxygen
More informationDGBOX rev Inverter electronic control panels for single pumps or pumping units OPERATOR S AND MAINTENANCE MANUAL
DGBOX rev. 60 EN Inverter electronic control panels for single pumps or pumping units OPERATOR S AND MAINTENANCE MANUAL Model V in V out A P (kw) P (HP) DGB MV 30 3 ~ 400V 3 ~ 400V 8 3 4 DGB MV 55 3 ~
More informationHeavy Duty Dissolved Oxygen Meter
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com Introduction Congratulations
More informationECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION
ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050
More informationControl units. Installation and operating instructions Series: Megacontrol
Control units Installation and operating instructions Series: Megacontrol Table of Contents 1 Introduction 1.1 Preface... 4 1.2 Icons and symbols... 4 2 Identification, service and technical support 2.1
More informationSOLENOID VALVES AND PNEUMATIC VALVES
9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated
More informationWind farm Simulink modelling and control through dynamic adjustment of wind turbines power set-point Saman Poushpas, Prof. W.
Wind farm Simulink modelling and control through dynamic adjustment of wind turbines power set-point Saman Poushpas, Prof. W.E Leithead Department of Electronics and Electrical Engineering, University
More informationACV-10 Automatic Control Valve
ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationType2 Oxygen probe system for Nexus NX6100 and PPC6000
Type2 Oxygen probe system for Nexus NX6100 and PPC6000 NXPK2244 MAY 7, 2018 Supplement to NEX6101 & PPC6001 1 of 27 1. Introduction This supplement is intended to be additional information to that contained
More informationUBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions
Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM
More informationCOMPACT Booster Sets Data Book 50Hz
Japanese Technology since 1912 COMPACT Booster Sets Data Book 50Hz 50Hz CONTENTS INDEX GP-GPE Page CONTENTS INDEX 2 DEFINITION AND USE OF PRESSURISATION UNITS 101 TYPICAL APPLICATIONS 101 PRINCIPLE OF
More informationInstallation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units
Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges
More informationWATER PRESSURE REDUCER (SBD)
WATER PRESSURE REDUCER (SBD) December 2016 PRODUCTS Product Code Connection Size Range of Products Max. Input Pressure Pressure Setting Range 340308 1/4" SBD 340315 1/2" SBD 340415 1/2" with sleeve coupling
More informationElectrical operating instructions
en Electrical operating instructions Door control panel TS 980 (Design and functions subject to change) 51171150 - b 07.2007 OPERATING AND INSTALLATION INSTRUCTIONS PAGE SAFETY DIRECTIONS...4 ENCLOSURE
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationWatts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available
-0 Watts AEH Series s from. V to 8 V xppower.com Non-standard s Available Universal Input Single & Multiple Versions 0 C to +60 C Operating Temperature Efficiency up to 80% Non-standard Connectors Available
More informationDifferential pressure controller (PN 16) AVPL - return mounting, adjustable setting
Data sheet Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting Description It can be used on primary side of house substations for smaller systems such as one and two-family
More informationGOLT! RED LIGHT DISTRICT
GOLT! RED LIGHT DISTRICT USER MANUAL v2.1 How RLD Works Signal Flow PROCESSOR The timing processor receives all clock signals and start stop commands. Its main function is to determine which timing signals
More informationType N-10, N-11 Hazardous Area Non-incendive Transmitters
Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial
More informationThe Regional Power Grid Team
The Regional Power Grid Team Presentation # 3: Network Results Karen Tapia-Ahumada Jehanzeb Noor Katherine Steel May 09, 2006 Power Grid Agenda Items Building Network Matrix and Images Network Level Results
More informationOperating instructions Pressure sensor. PP00xE /00 10/2011
Operating instructions Pressure sensor PP00xE 704962/00 0/20 Contents Preliminary note3. ymbols used 3 2 afety instructions 3 3 Functions and features 4 3. Application area 4 4 Function 4 4. Communication,
More informationVortex FlowmeterManual
Vortex Flowmeter Series MTGB Vortex FlowmeterManual Dalian Metern Measurement and Control System Co.,Ltd CONTENTS 1.GENERAL INFORMATION... 3 1.1 Product Description... 3 2.Technical Data... 4 3.Model and
More informationInstruction Manual. PLT Series. 1. General Specification. 2. Installation. 3. Wiring. 4. Function. 5. Setting & Calibration
4 Digit Display, 4-20mA Output Instruction Manual (Digital Differential Pressure Transmitter) 1. General Specification 2. Installation 3. Wiring 4. Function 5. Setting & Calibration 1 4 20 1 Differential
More informationCPE/EE 427, CPE 527 VLSI Design I L21: Sequential Circuits. Review: The Regenerative Property
CPE/EE 427, CPE 527 VLSI esign I L21: Sequential Circuits epartment of Electrical and Computer Engineering University of Alabama in Huntsville Aleksandar Milenkovic ( www.ece.uah.edu/~milenka ) www.ece.uah.edu/~milenka/cpe527-5f
More informationOC508 Programmable mv Calibrator
OC508_GBM_201609 OC508 Programmable mv Calibrator Owner s Manual Orbit Controls AG Zürcherstrasse 137 CH8952 Schlieren - ZH orbitcontrols.ch OC508 Programmable mv Calibrator Selection of DIN Thermocouples
More informationManual Weighingblock VB2 series and Uniscale
Manual Weighingblock VB2 series and Uniscale Note: At page 8 in this manual you will find a short form instruction. Normally the only instruction shipped together with the Scale. Overview different ranges.
More informationDimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)
Proportional damper actuator, non-spring return, Multi-Function Technology Torque min. Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) For proportional modulation of dampers in HVC systems. The is
More informationSRL Series. Oil-less Scroll Air Compressors. Pharmaceutical. Research & Development. Food & Beverage. Chemical. Electronic
Pharmaceutical SRL Series Oil-less Scroll Air Compressors Research & Development Food & Beverage Chemical Electronic Hitachi Industrial Equipment Product Brochure Hitachi SRL Series scroll compressors
More informationVLSI Design I; A. Milenkovic 1
Review: The Regenerative Property V i V o V i V o CPE/EE 47, CPE 57 VLSI esign I : Sequential Circuits epartment of Electrical and Computer Engineering University of labama in Huntsville leksandar Milenkovic
More informationTime Current Curves Series NRX NF and RF Circuit Breakers PXR 20/25 Trip Units
Series NRX NF and RF Circuit Breakers PXR 20/25 Trip Units Contents Description Page Revision notes....2 PXR catalog number convention....3 PXR 20 trip units....4 PXR 25 trip units....5 Curves Long Delay
More informationTie Breaking Procedure
Ohio Youth Basketball Tie Breaking Procedure The higher seeded team when two teams have the same record after completion of pool play will be determined by the winner of their head to head competition.
More informationunconventional-airsoft.com
unconventional-airsoft.com Congratulations on your new digital fire control computer! This unit will change the way you use and look at your electric gun. With this short document, you will know all you
More informationCalibration Summary of Test Report No.: Sample
Calibration Summary of Test Report No.:30043 Rion Type: NL52/EX Serial no: 00732122 Customer: Scantek, Inc. Address: 6430 Dobbin Rd., Suite C, Columbia MD, 21045 Contact Person: Mariana Buzduga Phone No.:
More information