Nobeyama 45m telescope Summary of the last season & Plan for the next season

Size: px
Start display at page:

Download "Nobeyama 45m telescope Summary of the last season & Plan for the next season"

Transcription

1 Nobeyama 45m telescope Summary of the last season & Plan for the next season

2 45m Organization and member Director Kuno Science manager Takano Instrument manager Kanzawa Mitaka Umemoto Mikoshiba Open use secretary Hatakeyama & Ide Computing group Takahashi Maekawa Miyazawa, K. Oya Tatamidani Kinugasa Nishitani Receiver, IF group Iwashita Miyazawa, C. Ishikawa Saitoh Morokuma Minamidani Antenna, PANDA, AOS group Kanzawa Handa Wada (Morokuma)

3 Summary of the last season (Dec June 2013) Start up measurements, adjustment, & internal use: November 5, 2012 TZ1 released to the open use T100 decommissioned T70 FOREST mounted (1st): December 5, st open use: January 7, 2013 June 8 Z45 mounted: March 26, 2013 End of the operation: June 11, 2013 Start of the maintenance: Computer replace: until July 31, 2013

4 Number of proposals Category Submitted Accepted General: 1st period (3 from abroad) General: 2nd period (4 from abroad) Short Program 15 9 (1 from abroad) Education Program 3 1 Back-up Program 1 1 See also a report of the time allocation sub-committee

5 Number of hours (last season) Open use Trouble, Bad weather Additional allocations VERA open use 2061 (661.5) (288) (646.5) (395) (658) (325) 58 Open use: TOTAL Internal use Calibration, Development, Test Internal use: TOTAL Maintenance (Tuesday) Blank (short slots) open use To

6 Big troubles October 2012: Rusty subrefrector (X axis) guides Replaced by antenna group March 1, 2013: Water leak onto the Mitsubishi rack

7 Other troubles, problems Spurious from PANDA (AD converter) (continued) Originated from the AD chips Unstable nature of the new system (SW BOX + New IF + PANDA + SAM45) (continued) Number of troubles decreased, but sometimes it happens. Please continue to follow the instructions in the website of zobs (Use of arrays with pairs, etc).

8 Results from the questionnaires Achievement (%) Then, additional observational time allocated. 19 projects Based on their achievement reports (due to trouble, bad weather, etc.)

9 Others Remote observations (1st year) From Mitaka (ALMA building) Limited open for experienced users 1 project + test obs. Open for observations only with the SAM45 spectrometers Summer schools Summer school for radioastronomy (NRO) July 30-August 3, 2012 Number of students: 12 Summer school (Joetsu University of Education) August 6-8, 2012 Number of students: 4 Summer school (University of Tokyo) August 8-11, 2012 Number of students: 5

10 Plan for the next season (Dec June 2014) The 32nd open use: Deadlines (fixed to date) Category Deadline (2013) 15:00 JST [06:00 UT] General Proposal: 1st period September 1 General Proposal: 2nd period December 10 Short Program December 22 Education Program September 1 & December 10 Back-up Program September 15 Please use a revised cover sheet cut & paste results of the time estimator (explain input parameters, and refer the output results) check the list of legacy projects in the 45m website before writing your proposals

11 Instruments & software Roughly the same system as the last season (New system: Maximum number of IF 16), but computers replaced! TZ2 receiver released for ON-ON observations Two beam receiver with TZ1 Beam separation ~ 46 arcsec Mainly for a point source T70 receiver released for sensitive observations in the 70 GHz region (risk share) GHz FOREST (4 beam receiver) is not released

12 Instruments & software (2) PANDA spurious The AD chips are the origin of the spurious. We replace the chips and prepare an additional PANDA. In December, 2 IFs will be in good condition. Until March 10 IFs in total will be in good condition. Remote observations From Mitaka, NAOJ (ALMA building) Open to experienced users Open for observations only with the SAM45 spectrometers Please contact Dr. Umemoto at Mitaka in advance (~ 2 weeks) (cc: to Takano)

13 AC45 spectrometer Uneven intensity nature was re-recognized. From our website In addition, season dependence may exist. With respect to AOS: About 20-30% weak About 0-20% weak

14 AC45 spectrometer Uneven intensity nature was re-recognized. From our website In addition, season dependence may exist. BEARS (+AC45) scaling factor will be obtained by us as before. For single beam RX + AC45: (1) We recommend not to use. (2) But, if you use (e.g., S100 OTF), please calibrate by yourself (Sorry). With respect to AOS: About 20-30% weak About 0-20% weak

15 About the 45m assistant Same as before, but policy or scope of the assistant was documented. NRO recommends that observers learn basic operations with technical support from the NRO assistant so that they can conduct observations by themselves. 1 hr break Occasionally work at the main building To be uploaded in the 45m website

16 Others Summer schools Summer school for radioastronomy (NRO) September 17-21, 2013 Number of students: 8 or 12 Deadline July 29 Summer school (University of Tokyo) October, 2013 Summer school (Joetsu University of Education) October, 2013

17 Others Taurus: Close to the Sun after the middle of April Additional observational time is hard to allocate for General Proposal: 2nd period Sometimes the control room is in disorder some garbage (including the remains left after a meal and refreshments, and gum) So we request the observers to

18 Number of papers (red lines: 45m) Number of Papers total 45 NMA/RAINBOW ASTE other Number of Papers year

19 Number of papers (red lines: 45m) Number of Papers 70 Please send your scientific and technical results 60 to introduce in the NRO website! Title 30 A figure (about 150 by 150 pixels) and its caption 20 Abstract (about 100 words) 10 0 Number of Papers For details, please see below or contact us year total 45 NMA/RAINBOW ASTE other

NRO Report and Plans for 2016/2017. Masao Saito (Nobeyama Radio Observatory)

NRO Report and Plans for 2016/2017. Masao Saito (Nobeyama Radio Observatory) NRO Report and Plans for 2016/2017 Masao Saito (Nobeyama Radio Observatory) Outline 1. NRO Missions 2. NRO Activities 2015 2016 2016 3. NRO Open use 1. 2015 2016 2. 2016 2017 4. Summary 2016/12/20 ALMA/NRO/ASTE

More information

New Technological Guidelines Required for Pipette Management (Proposal of a Pipette Management Method)

New Technological Guidelines Required for Pipette Management (Proposal of a Pipette Management Method) New Technological Guidelines Required for Pipette Management (Proposal of a Pipette Management Method) R&D Division 5 A&D Company, Limited 2010/9/2 First of All Differences in dispensing volume of pipettes

More information

ALMA Status Update. October ALMA Doc 1.17, ver. 1.1 October 02, 2013

ALMA Status Update. October ALMA Doc 1.17, ver. 1.1 October 02, 2013 ALMA Doc 1.17, ver. 1.1 October 02, 2013 ALMA Status Update October 2013 ALMA, an international astronomy facility, is a partnership of Europe, North America and East Asia in cooperation with the Republic

More information

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING Blair Chalpin Charles A. Matthews Mechanical Design Engineer Product Support Manager Scanivalve Corp Scanivalve Corp Liberty Lake, WA

More information

Specifications and information are subject to change without notice. Up-to-date address information is available on our website.

Specifications and information are subject to change without notice. Up-to-date address information is available on our website. www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp LD302 - AssetView HMI LD302

More information

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator

Title: Standard Operating Procedure for R&R Environmental Devices Model MFC201 Gas Dilution Calibrator Procedure No: SOP-029 Revision No: 1.1 (December 29, 2010) Page No.: 1 of 7 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting, air quality

More information

Remote Control Bait Boat

Remote Control Bait Boat CARPIO 2.0 User Manual All pictures shown are for illustration purpose only. Actual product may vary due to product enhancement Remote Control Bait Boat (Smart Remote Control at 868 MHz) 1 Table of Contents

More information

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM

Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters

More information

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW

AC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi

More information

Artificial Intelligence for the EChO Mission Scheduler

Artificial Intelligence for the EChO Mission Scheduler Artificial Intelligence for the EChO Mission Scheduler Álvaro García Piquer Ignasi Ribas Josep Colomé Institute of Space Sciences (CSIC/IEEC), Barcelona, Spain SCIOPS 2013 September 10 13, 2013 Introduction

More information

Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers

Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers Mayda Velasco 1 Gianni Tassotto 3 on behalf of the SIC team P. Ball 2, A.Dabrowsky 1, G. Graham 2, C. Kendziora 3,

More information

Midland Junior Premier League

Midland Junior Premier League Midland Junior Premier League Guide to General Administration Louise Roden Contents How to Register Players... 2 FA Full Time Player Registration... 4 Transfers... 5 Arranging the Game... 6 Match Day...

More information

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73

USER MANUAL. Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * 1/73 USER MANUAL Intelligent Diagnostic Controller IDC24-A IDC24-AF IDC24-AFL IDC24-F IDP24-A * IDP24-AF * IDP24-AFL * IDP24-F * *) Require software ID: DID-SW-001 1/73 Table of contents 1 General... 3 1.1

More information

Air Diving Inspection of ABC Mock-Up Caisson Project 123

Air Diving Inspection of ABC Mock-Up Caisson Project 123 Air Diving Inspection of ABC Caisson Project 123 Client: CLIENT Facility: CDE, Norway Item Inspected: ABC Caisson Inspection Method: Manual Surface Eddy Current Date Commenced: 04 November 2013 Date of

More information

HYDROGRAPHIC AND SITE SURVEY REPORT

HYDROGRAPHIC AND SITE SURVEY REPORT HYDROGRAPHIC AND SITE SURVEY REPORT Proposed Pen Site at Dounie, Sound of Jura Prepared for: Kames Fish Farming Ltd Kilmelford Argyll PA34 4XA Tel: +44 (0)1631 720699 TransTech Limited www.transtechltd.com

More information

Monthly Mission Review. Project Status Overview. June 6, Ken Fouts SLAC Gamma-ray Large Area Space Telescope

Monthly Mission Review. Project Status Overview. June 6, Ken Fouts SLAC Gamma-ray Large Area Space Telescope Gamma-ray Large Area Space Telescope Monthly Project Status Overview Ken Fouts SLAC kfouts@slac.stanford.edu K.A. Fouts, SLAC 1 LAT Project Status 5/7 LAT EMI Closeout complete 5/12-13 Supported Observatory

More information

Oxygen sounding thermal profiler for ALMA

Oxygen sounding thermal profiler for ALMA Oxygen sounding thermal profiler for ALMA Bojan Nikolic & Emily Curtis Cavendish Laboratory, University of Cambridge August 2010 OSF Nikolic & Curtis (University of Cambridge) O2 sounder for ALMA August

More information

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #:

ID-Cube. Installation and Operations Manual For ID-Cube Source and Power Supply. Revision 2 Document #: ID-Cube Installation and Operations Manual For ID-Cube Source and Power Supply Revision 2 Document #: 7.1.002 IonSense Inc. 999 Broadway Suite 404 Saugus, MA 01906 Copyright 2014 by IonSense Inc. All rights

More information

The PyMca Application and Toolkit V.A. Solé - European Synchrotron Radiation Facility 2009 Python for Scientific Computing Conference

The PyMca Application and Toolkit V.A. Solé - European Synchrotron Radiation Facility 2009 Python for Scientific Computing Conference The PyMca Application and Toolkit V.A. Solé - European Synchrotron Radiation Facility 2009 Python for Scientific Computing Conference Slide: 1 The ESRF: Just an X-Ray Source Slide: 2 (Partial) Synchrotron

More information

COMPARISON OF CONTEMPORANEOUS WAVE MEASUREMENTS WITH A SAAB WAVERADAR REX AND A DATAWELL DIRECTIONAL WAVERIDER BUOY

COMPARISON OF CONTEMPORANEOUS WAVE MEASUREMENTS WITH A SAAB WAVERADAR REX AND A DATAWELL DIRECTIONAL WAVERIDER BUOY 31 Bishop Street, Jolimont Western Australia 6014 T +61 8 9387 7955 F +61 8 9387 6686 E info@rpsmetocean.com W rpsmetocean.com & rpsgroup.com.au COMPARISON OF CONTEMPORANEOUS WAVE MEASUREMENTS WITH A SAAB

More information

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve

Acoustic Emission Testing of The Shell 0f Electromagnetic Valve 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Acoustic Emission Testing of The Shell 0f Electromagnetic Valve guozhen XU 1, yiwei CHEN 1, zhihua CAO 2 ABSTRACT Shanghai

More information

Standard Operating Procedures (SOP) for Desert Locust Ground Control. 2 Desert Locust Ground Control SOP. 1. Control process.

Standard Operating Procedures (SOP) for Desert Locust Ground Control. 2 Desert Locust Ground Control SOP. 1. Control process. Standard Operating Procedures (SOP) for Desert Locust Ground Control Objective The objective of the Standard Operating Procedures (SOP) for Desert Locust Control is to give concise instructions for good

More information

SPIRIT III Radiometer Saturation Effect

SPIRIT III Radiometer Saturation Effect Utah State University DigitalCommons@USU Space Dynamics Lab Publications Space Dynamics Lab 1-1-1997 SPIRIT III Radiometer Saturation Effect Joseph J. Tansock Follow this and additional works at: https://digitalcommons.usu.edu/sdl_pubs

More information

Standard Operating Procedure for H 2 S and SO 2 Converter

Standard Operating Procedure for H 2 S and SO 2 Converter Procedure No: SOP-001 Revision No: 1.0 January 24, 2011 Page No.: 1 of 6 1. INTRODUCTION AND SCOPE This procedure describes the operation and configuration of heated converters used in continuous ambient

More information

ROSE-HULMAN INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering. Mini-project 3 Tennis ball launcher

ROSE-HULMAN INSTITUTE OF TECHNOLOGY Department of Mechanical Engineering. Mini-project 3 Tennis ball launcher Mini-project 3 Tennis ball launcher Mini-Project 3 requires you to use MATLAB to model the trajectory of a tennis ball being shot from a tennis ball launcher to a player. The tennis ball trajectory model

More information

COSMO INSTRUMENTS CO., LTD.

COSMO INSTRUMENTS CO., LTD. Specification Sheet COSMO AIR LEAK TESTER ModelLS-1861 Meets SI Unit Requirement Improved accuracy with the new Master-Preset compensation feature Compensates for environmental changes Improves cycle time

More information

Paper Session II-C - Verification of International Space Station Component Leak Rates by Helium Accumulation Method

Paper Session II-C - Verification of International Space Station Component Leak Rates by Helium Accumulation Method The Space Congress Proceedings 2003 (40th) Linking the Past to the Future - A Celebration of Space May 1st, 1:30 PM - 4:30 PM Paper Session II-C - Verification of International Space Station Component

More information

Windcube FCR measurements

Windcube FCR measurements Windcube FCR measurements Principles, performance and recommendations for use of the Flow Complexity Recognition (FCR) algorithm for the Windcube ground-based Lidar Summary: As with any remote sensor,

More information

Improving distillation tower operation

Improving distillation tower operation Improving distillation tower operation Measuring differential pressure across long sections of distillation columns has always been challenging, but purpose-built sensor systems provide a solution Fast

More information

COMPARISON OF CONTEMPORANEOUS WAVE MEASUREMENTS WITH A SAAB WAVERADAR REX AND A DATAWELL DIRECTIONAL WAVERIDER BUOY

COMPARISON OF CONTEMPORANEOUS WAVE MEASUREMENTS WITH A SAAB WAVERADAR REX AND A DATAWELL DIRECTIONAL WAVERIDER BUOY COMPARISON OF CONTEMPORANEOUS WAVE MEASUREMENTS WITH A SAAB WAVERADAR REX AND A DATAWELL DIRECTIONAL WAVERIDER BUOY Scott Noreika, Mark Beardsley, Lulu Lodder, Sarah Brown and David Duncalf rpsmetocean.com

More information

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions L 100 Bubble-Tube Level System Installation, Operation and Maintenance Instructions Figure 1 Contents Section Description Page 1.0 Introduction 2 2.0 Specifications 3 3.0 Installation 3 4.0 Warranty 6

More information

Newsletter nº 2 May 2015

Newsletter nº 2 May 2015 Newsletter nº 2 May 2015 Measurement system setup Ajdovščina Fig. 1: The measurement system in Ajdovščina 1 Wind Risk project is being implemented with the contribution of the Civil Protection Financial

More information

Laboratory 2(a): Interfacing WiiMote. Authors: Jeff C. Jensen (National Instruments) Trung N. Tran (National Instruments)

Laboratory 2(a): Interfacing WiiMote. Authors: Jeff C. Jensen (National Instruments) Trung N. Tran (National Instruments) Laboratory 2(a): Interfacing WiiMote Authors: Jeff C. Jensen (National Instruments) Trung N. Tran (National Instruments) Instructors: Edward A. Lee Sanjit A. Seshia University of California, Berkeley EECS

More information

Changes to Rules for Print and PDI Leagues

Changes to Rules for Print and PDI Leagues Changes to Rules for Print and PDI Leagues A number of changes are required to reflect updated procedures for uploading entries, appointment of judges, and to cover issues which arose during the course

More information

Anemometry. Anemometry. Wind Conventions and Characteristics. Anemometry. Wind Variability. Anemometry. Function of an anemometer:

Anemometry. Anemometry. Wind Conventions and Characteristics. Anemometry. Wind Variability. Anemometry. Function of an anemometer: Anemometry Anemometry Function of an anemometer: Measure some or all of the components of the wind vector In homogeneous terrain, vertical component is small express wind as -D horizontal vector For some

More information

Development of Large Capacity CO2 Scroll Compressor

Development of Large Capacity CO2 Scroll Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2008 Development of Large Capacity CO2 Scroll Compressor Kenji Yano Mitsubishi Electric

More information

Design of Matched H-Plane Tee

Design of Matched H-Plane Tee Advances in Wireless and Mobile Communications. ISSN 973-6972 Volume 1, Number 1 (217), pp. 79-87 Research India Publications http://www.ripublication.com Design of Matched H-Plane Tee Debendra Kumar Panda

More information

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology:

White Paper. Chemical Sensor vs NDIR - Overview: NDIR Technology: Title: Comparison of Chemical Sensor and NDIR Technologies TSN Number: 25 File:\\MII- SRV1\Metron\Bridge_Analyzers\Customer_Service_Documentation\White_Papers\25_G en EGA NDIR vs Chemical Sensor.docx Created

More information

APPLICATION NOTES DELOMATIC 4, DM-4 GAS

APPLICATION NOTES DELOMATIC 4, DM-4 GAS APPLICATION NOTES DELOMATIC 4, DM-4 GAS Emission control Lambda sensor p/t regulation Combustion chamber temperature regulation Emission control configuration Emission control curve Document no.: 4189340653C

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

How to use the PBM Flow Calculator Spreadsheet (V2.04)

How to use the PBM Flow Calculator Spreadsheet (V2.04) How to use the PBM Flow Calculator Spreadsheet (V2.04) o Navigate to the F:\Common\ENGINEERING\Common Design Calculations folder o o Open PBM FLOW CALC 2.04.xlsm On the title page, the version, version

More information

I/P Transducer Positioner Module

I/P Transducer Positioner Module I/P Transducer Positioner Module VRC P/N: 7958032 Installation, Operation and Maintenance Instructions 2.09 [53.1] 1.30 [32.9] 2.97 [75.5] 0.78 [19.8] 0.18 [4.4] 1.42 [36.1] n.18 MOUNTING HOLES (2) PLACES

More information

Quadruple mass spectrometers (transducer type)

Quadruple mass spectrometers (transducer type) Quadruple mass spectrometers that meet the need for sensitive analysis and low outgassing which were specifically designed to be controlled by PCs Quadruple mass spectrometers (transducer type) M-070QA-TDF,

More information

FLUORESCENCE DETERMINATION OF OXYGEN

FLUORESCENCE DETERMINATION OF OXYGEN FLUORESCENCE DETERMINATION OF OXYGEN Objectives This experiment will familiarize the students with the principles of fluorescence quenching as well as the Ocean Optics FOXY Fiber Optic Sensor System. Spectra

More information

Doc. no.dit om005 PRODUCT NAME. IO-Link/ELECTRO-PNEUMATIC REGULATOR. MODEL / Series / Product Number ITV*0*0-IO****-X395

Doc. no.dit om005 PRODUCT NAME. IO-Link/ELECTRO-PNEUMATIC REGULATOR. MODEL / Series / Product Number ITV*0*0-IO****-X395 Doc. no.dit-69900-om005 PRODUCT NAME IO-Link/ELECTRO-PNEUMATIC REGULATOR MODEL / Series / Product Number ITV*0*0-IO****-X395 This is the operation manual for the IO-Link compliant ITV. For other contents

More information

Water Samplers, Water Sampling with Internal Recording, Cabling, and Deployment

Water Samplers, Water Sampling with Internal Recording, Cabling, and Deployment Water Samplers, Water Sampling with Internal Recording, Cabling, and Deployment Water Samplers Care and feeding SeatermAF User interface for internally recording instruments firing water samplers with

More information

Miris Ultrasonic Processor

Miris Ultrasonic Processor Installation Qualification & Operational Qualification Figure 1. The 1. Sound reducing cabinet 2. Power supply unit Miris AB Kungsgatan 115 753 18 UPPSALA SWEDEN Tel: +46 18 14 69 07 e-mail: support@mirissolutions.com

More information

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience - Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience - Dr. Wolfgang Jockel, Martin Schneider, TÜV Rheinland Group, D-51105 Cologne / Germany 1. Introduction A new basis for the certification

More information

Lap Count Display Owner s Manual

Lap Count Display Owner s Manual Lap Count Display Owner s Manual Model 6673AW -Rev A Model 6673AX -Rev A RaceAmerica Corporation 105 Bonaventura Drive San Jose, CA 95134 (408) 988-6188 www.raceamerica.com info@raceamerica.com Copyright

More information

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300

Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300 Standard Operating Procedure Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) - Thermo Scientific icap 6300 The Thermo Scientific icap 6300 Inductively Coupled Plasma Optical Emission

More information

sensors ISSN

sensors ISSN Sensors 2010, 10, 9799-9807; doi:10.3390/s101109799 OPEN ACCESS sensors SSN 1424-8220 www.mdpi.com/journal/sensors Communication A Dipping Duration Study for Optimization of Anodized-Aluum Pressure-Sensitive

More information

Cover Page for Lab Report Group Portion. Pump Performance

Cover Page for Lab Report Group Portion. Pump Performance Cover Page for Lab Report Group Portion Pump Performance Prepared by Professor J. M. Cimbala, Penn State University Latest revision: 02 March 2012 Name 1: Name 2: Name 3: [Name 4: ] Date: Section number:

More information

In Vivo Scientific, LLC INSTRUCTION MANUAL

In Vivo Scientific, LLC INSTRUCTION MANUAL CO 2 Controller In Vivo Scientific, LLC INSTRUCTION MANUAL CONTENTS CONTENTS...1 ABOUT THIS MANUAL...2 INTRODUCTION...2 Cautions and Warnings...2 Parts List...2 Unpacking...2 INSTRUMENT DESCRIPTION...3

More information

Objectives Topics Resources & Notes GAIN ATTENTION Review homework answers for chapter 8 Slide 1 OBJECTIVE

Objectives Topics Resources & Notes GAIN ATTENTION Review homework answers for chapter 8 Slide 1 OBJECTIVE 9 Marine Steering Systems 83 COURSE LESSON TITLE PRESENTATION TIME PRESENTATION METHOD MATERIALS REQUIRED Chapter 9 Marine Steering Systems 2 hours Participative Lecture Ch9 PPT slides, computer, projector

More information

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers

A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers A Depletion Compensated Wet Bath Simulator For Calibrating Evidential Breath Alcohol Analyzers Slemeyer, A. University of Applied Sciences of Giessen, Dept. of Electrical Engineering 1 Wiesenstr. 14, D-35390

More information

The MRL Furnaces USED FOR THIS MANUAL COVERS

The MRL Furnaces USED FOR THIS MANUAL COVERS The MRL Furnaces USED FOR 1. Making Silicon Oxide films from 10nm to 2um thickness 2. Annealing with temperatures from 30 800C and times from 5min to 2days 3. Diffusion with temperatures from 30 1100C

More information

Horsham Indoor Bowls Club A Guide For New Members

Horsham Indoor Bowls Club A Guide For New Members Horsham Indoor Bowls Club A Guide For New Members On behalf of the Board of Directors & Club Committee we would like to welcome you to the Horsham District Indoor Bowls Club, and hope that your association

More information

ANALYSIS FOR WIND CHARACTERISTICS IN TELUK KALUNG, KEMAMAN, TERENGGANU Muhammad Hisyam Abdullah 1, Mohamad Idris Bin Ali 1 and Ngien Su Kong 1

ANALYSIS FOR WIND CHARACTERISTICS IN TELUK KALUNG, KEMAMAN, TERENGGANU Muhammad Hisyam Abdullah 1, Mohamad Idris Bin Ali 1 and Ngien Su Kong 1 International Journal of Science, Environment and Technology, Vol. 5, No 6, 2016, 3827 3833 ISSN 2278-3687 (O) 2277-663X (P) ANALYSIS FOR WIND CHARACTERISTICS IN TELUK KALUNG, KEMAMAN, TERENGGANU Muhammad

More information

ACV-10 Automatic Control Valve

ACV-10 Automatic Control Valve ACV-10 Automatic Control Valve Installation, Operation & Maintenance General: The Archer Instruments ACV-10 is a precision automatic feed rate control valve for use in vacuum systems feeding Chlorine,

More information

FOURIER TRANSFORM INFRARED SPECTROSCOPY

FOURIER TRANSFORM INFRARED SPECTROSCOPY Purpose and Scope: This document describes the procedures and policies for using the MSE Bruker FTIR Spectrometer. The scope of this document is to establish user procedures. Instrument maintenance and

More information

The latest automotive systems require innovative leak test methods and fixturing.

The latest automotive systems require innovative leak test methods and fixturing. Leak Testing Auto Parts The latest automotive systems require innovative leak test methods and fixturing. In the past, automobile manufacturers only required basic forms of leak testing to check standard

More information

Thermo Scientific Model 146i Principle of Operation

Thermo Scientific Model 146i Principle of Operation Thermo Scientific Model 146i Principle of Operation The Model 146i Multi-gas Calibrator dilutes calibration gases to precise concentrations. The diluted gases are used to perform zero, precision and Level

More information

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK

INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK INSTALLATION PROCEDURE 1/4 & 1/8 MILE PERMANENT TRACK 1) Unpack all of the equipment and immediately inspect for shipping damage. Damages should be immediately reported to the carrier and noted on the

More information

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator Procedure No: SOP-034 Revision No: 1.0 Revised Dec. 29, 2010 Page No.: 1 of 10 1. INTRODUCTION AND SCOPE This procedure is intended to describe the operations of the Dasibi model 5008 calibrator. The Dasibi

More information

Wind turbine Varying blade length with wind speed

Wind turbine Varying blade length with wind speed IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: 2278-1676,p-ISSN: 2320-3331, PP 01-05 www.iosrjournals.org Wind turbine Varying blade length with wind speed Mohammed Ashique

More information

PUSHOVER ANALYSIS OF STEEL STRUCTURE Santosh shet 1, Dr.Akshatha shetty 2 1

PUSHOVER ANALYSIS OF STEEL STRUCTURE Santosh shet 1, Dr.Akshatha shetty 2 1 PUSHOVER ANALYSIS OF STEEL STRUCTURE Santosh shet 1, Dr.Akshatha shetty 2 1 P.G Student, NMAMIT Engineering college Nitte Karkala, Karnataka,India 2 Assistant Professor NMAMIT Engineering college Nitte

More information

Revision Number Revision Date Insertion Date/Initials 1 st Ed. Oct 26, 00 2nd Ed. Jan 15, 08

Revision Number Revision Date Insertion Date/Initials 1 st Ed. Oct 26, 00 2nd Ed. Jan 15, 08 List of Effective Pages * Asterisk indicates pages changed, added, or deleted by current revision. Retain this record in front of handbook. Upon receipt of a Record of Revisions revision, insert changes

More information

Neil Kane Managing Director EMT UK

Neil Kane Managing Director EMT UK Neil Kane Managing Director EMT UK SF6 Measurement, Analysis, Diagnostics and Leak Detection Our goals at EMT are to supply Maintenance Operatives with the very best tools to protect both personnel and

More information

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230 Instruction Manual Digital Thermocouple Gauge Control Units Models DTC-531-115 & DTC-531-230 Models DTC-06M-115 & DTC-06M-230 Copyright 1998 by Duniway Stockroom Corp. 021315lh 1 of 7 Table of Contents

More information

Significant Change to Dairy Heat Treatment Equipment and Systems

Significant Change to Dairy Heat Treatment Equipment and Systems Significant to Dairy Heat Treatment September 2008 Page 1 Significant to Dairy Heat Treatment Equipment and Systems September 2008 1 Background Requirements for the assessment of dairy heat treatment equipment

More information

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR)

Title: Standard Operating Procedure for Elemental and Organic Carbon (EC and OC) using Non-Dispersive Infrared Detection (NDIR) Procedure No: SOP-025 Revision No: 1.0 (January 21, 2011) Page No.: 1 of 8 1. INTRODUCTION AND SCOPE To obtain timely data for the purpose of air quality assessment, air quality trend reporting and to

More information

Control Valve : The Final Control Element. Nimish Shah

Control Valve : The Final Control Element. Nimish Shah Control Valve : The Final Control Element Nimish Shah VALVES How to select Control Valve??? selection parameters for the valve : size, material of construction, pressure and temperature ratings, and End

More information

Top Level of CSC DCS UI

Top Level of CSC DCS UI Top Level of CSC DCS UI - CSC normally in central DCS control -cdcs - Central DCS shifter monitors the CSC system, but doesn't take any action without consulting with the CSC shifter - CSC Shifter also

More information

05-341r0: Updated Test and Simulation Results in Support of SAS-2. Kevin Witt, Mahbubul Bari, Brad Holway

05-341r0: Updated Test and Simulation Results in Support of SAS-2. Kevin Witt, Mahbubul Bari, Brad Holway 05-341r0: Updated Test and Simulation Results in Support of SAS-2 Kevin Witt, Mahbubul Bari, Brad Holway Equalization Overview Equalizers enable longer reach and higher data rates over band-limited channels.

More information

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale

Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale Troubleshooting Guide: 640 Pediatric Exam Table with Midmark Scale Contents Description Refer To: Scale Troubleshooting Chart Troubleshooting Error Codes Error Messages Adjustments / Repair Procedures

More information

LED Down Light (8 ) Dimension:

LED Down Light (8 ) Dimension: LED Down Light (8 ) Dimension: Specification Model No. LOR-DLC218R24F8-8 LOR-DLN218R24F8-8 LOR-DLW218R24F8-8 Input Voltage AC100-240V Rated Power 24W 24W 24W Luminous Flux 2040lm 1920lm 1800lm Luminous

More information

Lecture 04 ( ) Hazard Analysis. Systeme hoher Qualität und Sicherheit Universität Bremen WS 2015/2016

Lecture 04 ( ) Hazard Analysis. Systeme hoher Qualität und Sicherheit Universität Bremen WS 2015/2016 Systeme hoher Qualität und Sicherheit Universität Bremen WS 2015/2016 Lecture 04 (02.11.2015) Hazard Analysis Christoph Lüth Jan Peleska Dieter Hutter Where are we? 01: Concepts of Quality 02: Legal Requirements:

More information

What is ultrasonic plethysmography and how can we use it in airway disease?

What is ultrasonic plethysmography and how can we use it in airway disease? What is ultrasonic plethysmography and how can we use it in airway disease? Christian Buess ndd Medizintechnik AG, Zürich, Switzerland ERS 2007-1/19 Background Until approx. the year 2000 mainly the following

More information

Wicket Cards & Tags For Cashless Stored Value Payment Systems Rev: 10/2008

Wicket Cards & Tags For Cashless Stored Value Payment Systems Rev: 10/2008 Wicket Cards & Tags For Cashless Stored Value Payment Systems Rev: 10/2008 General Description: Wickets are laminated cards or tags having an ISO 15693 RFID (radio frequency identification) inlay in the

More information

Ref. no FUNCTIONS AND FEATURES

Ref. no FUNCTIONS AND FEATURES EN DIGITAL WIRELESS FUNCTIONS AND FEATURES 1. Current speed 2. Trip distance 3. Ride time 4. Average speed (2 decimal places) 5. Max. speed (2 decimal places) 6. Trip section counter (manual stopwatch

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at

More information

T6 FOR DUMMIES. version 1.0. Jan van Die

T6 FOR DUMMIES. version 1.0. Jan van Die T6 FOR DUMMIES version 1.0 Jan van Die INTRODUCTION Congratulations! You just bought a Suunto T6, one of the most sophisticated wristopcomputers for runners, and a footpod, a clever device to measure your

More information

Tutorial for the. Total Vertical Uncertainty Analysis Tool in NaviModel3

Tutorial for the. Total Vertical Uncertainty Analysis Tool in NaviModel3 Tutorial for the Total Vertical Uncertainty Analysis Tool in NaviModel3 May, 2011 1. Introduction The Total Vertical Uncertainty Analysis Tool in NaviModel3 has been designed to facilitate a determination

More information

ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN

ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN (This page intentionally blank) ATTACHMENT O WIPP MINE VENTILATION RATE MONITORING PLAN TABLE OF CONTENTS O- Definitions... O- Objective... O- Design

More information

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION Exercise 2-2 Second-Order Interacting Processes EXERCISE OBJECTIVE Familiarize yourself with second-order interacting processes and experiment with the finer points of controller tuning to gain a deeper

More information

This instruction is concerned with the monitoring of items in order to demonstrate that they are Exempt material. It describes:

This instruction is concerned with the monitoring of items in order to demonstrate that they are Exempt material. It describes: Clearance of materials, some experience from the UK Pete Burgess, Nuvia Ltd Symposium Recycling of Metals arising from Operation and Decommissioning of Nuclear Facilities Studsvik, Nyköping, Sweden, April

More information

Login to ilab Kiosk. Revised 05/22/2018. Load your sample:

Login to ilab Kiosk. Revised 05/22/2018. Load your sample: Login to ilab Kiosk Load your sample: 1. Check: The analysis chamber pressure is

More information

RESPIRATORY PHYSIOLOGY, PHYSICS AND

RESPIRATORY PHYSIOLOGY, PHYSICS AND Course n : Course 3 Title: RESPIRATORY PHYSIOLOGY, PHYSICS AND PATHOLOGY IN RELATION TO ANAESTHESIA AND INTENSIVE CARE Sub-category: Techniques Topic: Respiratory monitoring Date: May 05-07, 2016 Language:

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

LSG Single Point Failure Analysis

LSG Single Point Failure Analysis NO. I RIEV. NC j ATM-929 1._&11..1 DATE 5/18/71 The purpose of this ATM is to comment on the results of the single point failure analysis conducted on the lunar surface gravimeter experiment. It is to

More information

Team Manager's Manual

Team Manager's Manual Introduction: Team Managers Duties: Overview Team Manager's Manual Team Manager's Tasks Get your ScoreBook ID and Password from your League Administrator. Enter Your "Team Administration" Page Setting

More information

CNC Communication Protocol

CNC Communication Protocol CNC Communication Protocol Commands and Serial/Discrete Signals for the XPR Cutting System 809810 Revision 3 January 2018 CNC Communication Protocol for the XPR Cutting System 1 Contents Before you begin...

More information

Temperature Controllers

Temperature Controllers IM0004 April 2013 CONTENTS T-12 Thermostat PAGE Introduction 1 Scope 1 Description 1 Specification 1 Temperature Controllers 2 INTRODUCTION CAUTION Prior to installing, the instructions provided herein

More information

1)! DO NOT PROCEED BEYOND THIS MARK

1)! DO NOT PROCEED BEYOND THIS MARK Operating Instructions for X-ray Photoelectron Spectrometer: Physical Electronics Model 555 XPS/AES (John H. Thomas, III, Ph.D., Electron Spectroscopy) Sample Insertion: figure 1. Sample insertion rod

More information

This report includes:

This report includes: REPORT SUMMARY Page 1 of 15 In addition to this summary, this report includes the following forms: Report Summary al Failure Analysis Failure Categorization (One per ) Maintenance Task Selection (One per

More information

RAM 4021 Operation Manual

RAM 4021 Operation Manual RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For your safety...3 Description...3 Set-up mode...4 Annunciator lights/alarms...4 Operation...5 Calibration...6

More information

GN21 Frequently Asked Questions For Golfers

GN21 Frequently Asked Questions For Golfers Posting Scores (My Score Center) 1. Click on the Enter Score button to enter an adjusted gross score or click on the Enter Hole-By-Hole Score button to enter your score hole-by-hole. NOTE: to use the Game

More information

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features)

The Crossvent 2i+ 2. Ventilator Concept (brief theory of operation and features) The Crossvent 2i+ 1. How is this ventilator classified 2. Ventilator Concept (brief theory of operation and features) -Your Two Choices with this Ventilator 3. An overview of the device (an in-service)

More information

Determination of the wind pressure distribution on the facade of the triangularly shaped high-rise building structure

Determination of the wind pressure distribution on the facade of the triangularly shaped high-rise building structure Determination of the wind pressure distribution on the facade of the triangularly shaped high-rise building structure Norbert Jendzelovsky 1,*, Roland Antal 1 and Lenka Konecna 1 1 STU in Bratislava, Faculty

More information

ERS-1/2 Scatterometer new products: mission reprocessing and data quality improvement

ERS-1/2 Scatterometer new products: mission reprocessing and data quality improvement ERS-1/2 Scatterometer new products: mission reprocessing and data quality improvement Giovanna De Chiara (1), Raffaele Crapolicchio (1), Pascal Lecomte (2) (1) Serco SpA Via Sciadonna 22-24 Frascati (Roma),

More information