Airfield Lighting. Product Description. Omnidirectional Elevated Obstruction Light (F2.1, F22)
|
|
- Eustacia Hood
- 5 years ago
- Views:
Transcription
1 Product Description Omnidirectional Elevated Obstruction Light (F2.1, F22)
2 Note: This page is blank for convenient double-sided printing.
3 Safegate Group 1. INTRODUCTION Obstruction lighting is intended to reduce the hazards to aircraft by indicating the presence of obstructions. Fixed or mobile objects on super structures should be marked when they are in certain positions which might cause a collision risk near airports or heliports that can be used at night. Apart from the areas around an airport, it may be necessary to mark very high obstacles protruding into aircraft or helicopter traffic zones, such as radio antenna, chimney stacks or high voltage lines. Instructions concerning these requirements can be obtained from local airport authorities or navigation departments. The minimum requirements for obstruction lighting are specified by ICAO in Annex 14 Volume I Paragraph 6.3. According to these requirements, the protruding object must be marked using Low Intensity Obstruction Red Lights. F2.1 and F22 are omnidirectional elevated light. Utilisation Obstruction light Compliance ICAO: Annex 14 Volume I Paragraph 6.3 French STNA 2. MAIN ADVANTAGES Low cost. Low power consumption: Only 55 Watts. Power Supply: 230 Vac 50 / 60 Hz Lamp life greater than 8,000 hours (16,000 for the two lamps/f22). High speed lamp replacement by unscrewing the glass dome. Simple but sturdy design. Easy Installation and Maintenance. For F22: - Power Supply: A version of the F22 for supply in + 48 Vdc is available. - Security of the obstruction due to the 2nd safety lamp (automatic switching). - Main Lamp out back indication is possible, feed back of the voltage (230 Vac) present on the Safety Lamp. Page 1 of 8
4 Safegate Group 3. TECHNICAL CHARACTERISTICS Component Description Lamp: E27 socket lamps of 55 Watts. Lamp life of one lamp greater than 8,000 hours. Power supply: 230 Vac / (50-60 Hz) + 48 Vdc is possible for the F22. Photometry: Distribution and homogeneity comply with ICAO Annex 14. Colour: Obtained by full coloured glass dome. Chromaticity complies with Appendix 1 of ICAO Annex 14 Volume I. Finish: Body (F2.1 and F22) is made of aviation yellow full coloured polyamide reinforced with fibre glass. The supply / Switching box of the F22 is made in Aluminium alloy casting painted in aviation yellow. All fixings and fastening are stainless steel. Mounting: The Body of the F2.1 comprise a 21 Gas thread fixation hole at its bottom. The F22 have to be mounted on flange with four holes. Protection Class: IP34. Net weight: With the lamps Less than 1.5 kg for the F2.1 and less than 5 kg for the F22. Packing Data Designation Volume m3 Dimensions mm F2.1 fitting without optical glass or lamp x 270 x 270 Weight kg Red optical glass dome for E27 lamp (x 6) x 260 x Long frangible tube (x X) Short frangible tube (x X) Special tripod stand frangible tube (x X) 60 mm tube fixing accessory (x X) F22 fitting without lamp x E27 lamp (x 25) x 260 x Page 2 of 8
5 Safegate Group 4. INSTALLATION OPTIONS For F2.1: Surface level mounting on Tripod Stand with Long Frangible Holding Tube Stand (see Fig 1). Surface level mounting on Tripod Stand with Short Frangible Holding Tube Stand (see Fig 2). Up to 1.8 m on a Pole, a Frangible Coupling and Tripod Stand (see Fig 3). For F22: Mounting on all support using its four fixing holes (see Fig 4). Page 3 of 8
6 Safegate Group 5. PHOTOMETRICS This section includes photometric examples of different light configurations. Photometric examples Low Intensity Obstruction Light ICAO F2.1 and F22 (1 x 55 Watts) Red Light 6. DESIGN Components F F2-1 mounting support fixing screws 2. F2-1 mounting 3. E27 lamp holder 4. Lamp holder fixing screws 5. F2-1 gasket Watts 230 Vac E27 lamp 7. F2-1 red optical glass with Fresnel prism screwed in the mounting 8. Long frangible tube with locking screws 9. Short frangible tube with locking screws 10. F2.1 special tripod stand with fixing screw for frangible tube F Complete F F22 cover 13. F22 closing screw and washer 14. Connection terminal 15. Switching relay Vdc / 230 Vac power supply converter (option) 17. Components holding plate 18. F22 body with compression packers Page 4 of 8
7 Safegate Group 8. ORDER CODES The table below is a guide to order codes for a fitting with available component parts. Description F2.1 Fitting F2.1 mounting (without optical glass and lamp) Components F2.1+E27 Red optical glass dome for E27 lamp F2.1/FILTER/R Frangible tube Long frangible tube F2.1/LONG_FT Short frangible tube F2.1/SHORT_FT Special tripod stand for frangible tube F2.1/TRIPODE STAND 60 mm tube fixing accessory F2.1/60mm COUPLING Frangible coupling, 60 mm tube and standard tripod stand * F22 Fitting 230 Vac F22 Fitting (without lamps) F22/230Vac 48 Vdc F22 Fitting (without lamps) F22/48Vdc Lamp (x 1 for F2.1, x 2 for F22) E27 55 W Lamp E27/55W Note: An asterisk * denotes for more information, contact Safegate Group or see Page 5 of 8
8 Safegate Group 9. SPECIFICATION The F2.1 and F22 low intensity obstruction lights shall comply with ICAO recommendations in Annex 14, Volume I, paragraph 6.3 and with STNA standards concerning lighting of obstacles. These fittings shall be fitted with one (F2-1) or two (F22) E Vac lamp not exceeding 55 Watts. Lamp life of each lamp shall be greater than 8,000 hours (= 16,000 for the two lamps of F22). The optical systems shall comprise of just optical glass domes with Fresnel prisms, directly full coloured in red. The mounting of the F2.1 (used also on the F22) shall be made of polyamide reinforced with glass fibre, full coloured in yellow aviation. The water tightness between the optical glass dome and the F2.1 mounting is obtained using a flat gasket. The F22 Supply / Switching box is made in Aluminium alloy casting painted in aviation yellow. All fixings and fastening shall be stainless steel. They shall be design to allow easy installation and maintenance operations. With the lamps the weight shall not exceed 1.5 kg for the F2.1 and 5 kg for the F22. Their protection classes shall be IP34. The F2.1 shall be mounted at the level of the surface to mark, on tripod stand with a frangible holding tube, up to 1.8 m using a pole, a frangible coupling and a tripod stand or on any support ended by a 21 Gas Thread. The F22 shall be mounted on flange with four holes. Note: All descriptions and photometric characteristics in this publication present only general particulars and shall not form part of any contract. The right is reserved to change them without prior notification. Page 6 of 8
9 Safegate Group Note: This page is blank for convenient double-sided printing. Page 7 of 8
10 Safegate Group Check in to the future How many aircraft can your airport handle today? Can this number be increased without adverse effects on the airport s safety level? It is a known fact that traffic volume will rise in the foreseeable future. More movements will demand monitoring of the entire airport. Requirements will be sharpened and the development of an integrated system controlling not only ground movements but also air traffic close to the airport is of the highest interest. The International Civil Aviation Organization (ICAO) already describes A-SMGCS, Advanced Surface Movement Guidance and Control System, as the answer to the future modern airport need to control the entire airport space in one superior system. To a larger extent than today s systems, A-SMGCS will rely on automated processes to give both pilots and traffic controllers exact information about positions and directions. Safegate Group delivers complete A-SMGCS solutions already, as well as all vital parts relating to it. Safegate Group can check your airport into the future today! Safegate Group HQ Djurhagegatan 19 SE Malmö, Sweden Phone: +46 (0) Fax: +46 (0) market@safegate.com Brazil brazil@safegate.com Finland finland@safegate.com +358 (0) India india@safegate.com Malaysia malaysia@safegate.com Singapore singapore@safegate.com Spain spain@safegate.com Australia australia@safegate.com +61 (0) China china@safegate.com France france@safegate.com +33 (0) Qatar qatar@safegate.com UK uk@safegate.com +44 (0) Austria office@avibit.com Dubai dubai@safegate.com Germany germany@safegate.com +49 (0) Russia russia@safegate.com USA usa@safegate.com Safegate Group offers solutions for increased safety, efficiency and environmental benefits to airports worldwide. The company was founded in 1973 and has its headquarters in Malmö, Sweden. Safegate Group has more than 70 partners around the globe in order to be close to its customers. Earlier members of Safegate Group include Thorn AFL and Idman, who Page both 8 have of 8 over 40 years of experience in airfield lighting solutions for airports and heliports. The latest member of Safegate Group is Avibit, a leading provider of next generation software applications and integration of efficient air traffic control systems. Safegate Group s complete range of products and services, a one-stop shop, provides solutions to customers and airborne travellers around the globe.
Airfield Lighting. Omnidirectional Elevated Light (F2.1) Product Description
Product Description Omnidirectional Elevated Light (F2.1) F.A.T.O: Final Approach and Take Off area T.L.O.F: Touchdown and Lift Off area Heliport Approach Taxiway Edge Apron Edge Note: This page is blank
More informationAirfield Lighting Product Description F2.1
F2.1 Omni-directional elevated light F.A.T.O: Final Approach and Take Off area T.L.O.F: Touchdown and Lift Off area Heliport Approach Taxiway Edge Apron Edge Low Intensity Obstruction Note: This page is
More informationLess power great performances
148 SMART SMART Less power great performances SMART is the answer to the increasing demand for both low energy consumption and high efficiency. Based on many years experience in road lighting, it offers
More informationWINDSOCK MASTS TECHNICAL INFORMATION
WINDSOCK MASTS TECHNICAL INFORMATION CONTENTS are one of the largest manufactures of fibreglass masts in Europe with an international presence that spans across Europe, Asia, USA, The Middle East, and
More informationTECHNICAL MANUAL. DHR70N Polar. Den Haan Rotterdam
TECHNICAL MANUAL DHR70N Polar SINCE 1922 Den Haan Rotterdam WARNING! - Turn power off before inspection, installation or removal - Keep combustible materials away from lamp - Allow lamp/fixture to cool
More informationINSTRUCTION MANUAL Pressure Relief Device LPT
INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF
More information1000/13.02 KOBSERT. Thread inserts for metals
1000/13.02 KOBSERT Thread inserts for metals Contents KOBSERT Thread inserts for metals Page The principle 3 The benefits 3 Product types 3 Applications in the Automotive and General industry 4 Technical
More informationNEW TYPE M PRESSURE RELIEF DEVICE
NEW TYPE M PRESSURE RELIEF DEVICE M PRESSURE RELIEF DEVICE ACCORDING TO EN 50216-5/A2 PATENTED 2 PRESSURE RELIEF DEVICE TYPE 50 M Section A-A 170 139 Transformer tank F 41.5 3 ø48.3 ø166 A P.R.D. TAG A
More informationJunction Boxes Series 8118
> Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. WaterMaster FEW530 Electromagnetic water meter
ABB MEASUREMENT & ANALYTICS DATA SHEET WaterMaster FEW530 Electromagnetic water meter 2 WATE RMASTE R F E W 530 ELECT ROMAGNE TIC WATE R ME TE R DS/FE W530/FE T3 -E N RE V. A Measurement made easy Cost
More informationSafety Rope Pull Switches SR and SRM
Safety Rope Pull Switches SR and SRM Safety Rope Pull Switches For more safety on the production line Whether on the conveyor belt or on the machine when maximum safety is required, BERNSTEIN rope pull
More informationMounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity
Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating
More informationTECHNICAL MANUAL DHR70N. Den Haan Rotterdam
TECHNICAL MANUAL DHR70N SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete or incorrect.
More informationTHIS IS INDRA NAVIA COMPANY HISTORY. Gustav A Ring AS established (GAREX) Norsk Marconikompani AS established (NORMARC)
THIS IS INDRA NAVIA Indra Navia is a dedicated air traffic management technology company. We design, produce, integrate and support airport communication, navigation and tower systems. Our highly customized
More informationKGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2
KGW - ISOTHERM Germany 76185 Karlsruhe Gablonzer Straße 6 Tel. 0049 / 721 / 95897-0 Fax. 0049 / 721 / 95897-77 email:info@kgw-isotherm.de Internet: www.kgw-isotherm.de Operating Instructions Level controlling
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationPRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel
PRODUCT SUPPORT MANUAL YACHT BEAM 6M Searchlight Remote Control System with Joystick Remote Control Panel The Yacht Group - 4545 Ponce de Leon Blvd. Coral Gables FL 33146 Tel. 305.667.5811 - Fax. 305.663.5551
More informationTECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam
TECHNICAL MANUAL DHR80 LED SIN CE 922 Den Haan Rotterdam TABLE OF CONTENTS Disclaimer Technical data Product photos Dimensions Available models Exploded view - base mounting Electrical specification Electrical
More informationGas Pressure Regulator HON 200
Product information serving the gas industry worldwide Applications, characteristics, technical data Application Gas supply to municipal, industrial and individual consumers Regulator for low-load rails
More informationAutoChanger Installation & User Guide Issue 2
1 INDEX Page 1. Introduction... 3 2. AutoChanger Components Guide 4 3. Installation. 5-11 a) Installation Guidelines.. 5 b) Installation Retrofit... 6-11 c) Installation New... 11 4. AutoChanger User Guide
More informationMounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type
Type 4708 Supply Pressure Regulators Translation of original instructions Type 4708-53 Type 4708-64 Type 4708-12 Mounting and Operating Instructions Edition March 2018 Note on these mounting and operating
More informationCFSW. Hinges with built-in safety multiple switch
CFSW. Hinges with built-in safety multiple switch ELESA Original design Elesa Standards Main dimensions Fitting Weight Code Description L B f ±0.2 f 1 ±0.2 H h 1 h 2 d 3 d 4 C [Nm]# g 426601 CFSW.110-6-2NO+2NC-C-A
More informationOPTIMUM 700 BRATT PANS GAS & ELECTRIC BUILDER S SPECIFICATIONS. Part D: Maintenance instructions 3BE390838NM
OPTIMUM 700 BRATT PANS GAS & ELECTRIC BUILDER S SPECIFICATIONS Part D: Maintenance instructions - WARRANTY - In order to guarantee this equipment, we recommend that you comply with the MANUFACTURER S INSTRUCTIONS
More informationModel NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters
Data Sheet DS/NDA-EN Rev. H Model NDA Differential pressure transmitter Deltapi N Series A complete range of pneumatic pressure transmitters Introduction The blind type differential pressure transmitter
More informationPLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions
PLAQUE MFM0680 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM0680... 4 Power Supply Unit MPS021000
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic
More informationMUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.
Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read
More informationMasoneilan* Model 78-80H & 08-80H Transfer Valves
GE Oil & Gas Masoneilan* Model 78-80H & 08-80H Transfer Valves Instruction Manual GE Data Classification: Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE
More informationFEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG
PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG TECHNICAL CHARACTERISTICS Number of ways / positions : 3/2, 3/3, 5/2, 5/3, 5/4 Nominal sizes (ND) : 4, 6, 9, 12 Medium : compressed
More informationmicrotec 865 New from Beissbarth: wheel-balancing with the electronic easyfix data recording arm. All the best for your automobile service.
New from Beissbarth: wheel-balancing with the electronic easyfix data recording arm. All the best for your automobile service. Technology and user convenience guarantee high performance in your workshop.
More informationCFSW. Hinges with built-in safety multiple switch
CFSW. Hinges with built-in safety multiple switch ELESA Original design technical informations Material - Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black colour. Resistant to solvents,
More informationCABRIO LAMPS REFLECTORS CHARACTERISTICS LUMINAIRES LIGHT DISTRIBUTION THREE SIZES, MULTIPLE PHOTOMETRIC SOLUTIONS
H CHARACTERISTICS LUMINAIRES LAMPS REFLECTORS Models Mini Midi Maxi Reflectors 1627 1954 1552 (*) 1289 1552 1954 High-pressure 150 W 250 W 250 W 400 W 250 W 250 W sodium Metal halide 150 W 250 W 250 W
More informationType Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN
Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used
More informationOperating Instructions
LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More informationDialight LED Conveyor Light - CE / RCM. for Indoor and Outdoor Industrial Applications
Dialight LED Conveyor Light - CE / RCM for Indoor and Outdoor Industrial Applications Conveyor Light Products Vigilant LED Conveyor Light - CE / RCM Standard Model Mechanical Information: Fixture weight:
More informationFlamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps
Airfix D-E 6442.eps GB Installation and operating instructions 1999, Exclusion of liability All operation and maintenance related technical information, data and instructions contained in these installation
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)
More informationMECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET
CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS CONSTRUCTION FEATURES ENCLOSURE OPERATING TEMPERATURE 20 C/+60 C COVER Diecast aluminium (anodised) WEIGHT CSN 5 3.5 kg CSN 8 5 kg CSN
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to
More informationTECHNICAL MANUAL DHR80 LED. Den Haan Rotterdam MED96/98/EC
TECHNICAL MANUAL DHR80 LED MED96/98/EC SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete
More informationenclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)
enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) Stainless steel and plastic enclosures for use in potentially explosive environments R Rittal system partners Perfect
More informationPressure switch and Thermostat CAS
Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to
More informationRobLight FL 1500 B-2. User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn. Phone:
98082129 22-08-2018 Rev. 2.6 User manual FL 1500 B-2 A/S Nordhavnsvej 1A DK - 9900 Frederikshavn Applies to: + 0130 0058 FL 1500 B-2 3000K CRI 90+ + 0130 0068 FL 1500 B-2 4000K CRI 90+ + 0130 0658 FL 1500
More informationDHR40 LED TECHNICAL MANUAL
DHR0 LED TECHNICAL MANUAL SIN CE 9 Den Haan Rotterdam TABLE OF CONTENTS Disclaimer Technical data Dimensions Available models Exploded view - base mounting Exploded view - side mounting Exploded view -
More informationIECEx Certificate of Conformity Annexe
for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment
More informationSECTION 2 RING MOUNT
SECTION 2 RING MOUNT Rotax aircraft engines are manufactured and supported by Rotax GmbH of Austria. Read and understand the Rotax manuals completely before starting with the engine installation, as they
More information1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
More informationTERMINAL BLOCK SUMMARY
TERMINAL BLOCK SUMMARY TERMINAL BLOCK SUMMARY TERMINAL BLOCK SUMMARY FEEDTHROUGH TERMINALS FUSE TERMINALS DISCONNECT TERMINALS MICRO TERMINALS CIRCUIT BREAKERS PRODUCT INFORMATION Feedthrough Terminals
More information61 Series Pilots for Pilot-Operated Pressure Reducing Regulators
61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally
More informationAlhambra Arabic design, British engineering
Alhambra Arabic design, British engineering A UNIQUE STYLE FOR ANY ENVIRONMENT / 036 / /// Unique inspiration and expertise Inspired by the original decorations of the Alhambra Palace in Granada, Spain,
More informationInfrared Linescanners
Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories LSPHD Mountings and Accessories
More informationDräger RZ 7000 Test Equipment
Dräger RZ 7000 Test Equipment Easy to use: With the Dräger RZ 7000 you can carry out the function and leak tests of the Dräger PSS BG 4 plus easier and faster than ever before. 02 Dräger RZ 7000 Benefits
More informationspeed monitor swe-compact
speed monitor swe-compact opto-electronic leaflet no. Kiepe 114 general The electronic rotational speed monitor SWE-compact comprises constructively the opto-electronic pulse transducer, the speed analysing
More informationMounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators
Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationWater Flow Regulators. The Leading Water Flow Regulator Worldwide. Essential Equipment For every injection and blow molding machine
The Leading Water Flow Regulator Worldwide Essential Equipment For every injection and blow molding machine Why You Should Use Wittmann Water Flow Regulators: Instant indication of blocked mold cooling
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION Model No. Description RP2300FC, RP2301FC Router CONCEPT AND MAIN APPLICATIONS Models RP2300FC and RP2301FC are upgraded sister tools of our current plunge-type electronic router Model
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:
More informationE10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.
> Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to
More informationTANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR
SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE
More informationAdjustable swirl diffuser ODZA TECHNICAL DATA
Adjustable swirl diffuser ODZA TECHNICAL DATA 2 Adjustable swirl diffuser ODZA Adjustable ceiling swirl diffuser ODZA is intended for commercial and industrial buildings with a large room volume and high
More informationTECHNICAL MANUAL DHR60 LED. Den Haan Rotterdam MED96/98/EC
TECHNICAL MANUAL DHR60 LED MED96/98/EC SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete
More informationCONUS MSR0680 UNDERWATER LIGHT. Registered Community Design. Operating Instructions
CONUS MSR0680 UNDERWATER LIGHT Registered Community Design Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light CONUS MSR0680... 4 Power
More informationDatasheet liniled Handrail 48.3 V1017 IK10 IP68. F RoHS IP40/IP65 FROST CLEANING AGENTS RESISTANT UV RESISTANT
Datasheet liniled Handrail 4 V1017 F RoHS IP40/IP65 IP68 IK10 AISI 316 UV RESISTANT FROST CLEANING AGENTS RESISTANT Handrail 4 Product information Technical specifications Product specifcations Required
More informationType 4708 Supply Pressure Regulator
Type 708 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point range 0.5 to bar (8 to 90 psi) The pressure regulator
More informationFisher 2625 and 2625NS Volume Boosters
Product Bulletin D200071X012 2625 and 2625NS Volume Boosters Fisher 2625 and 2625NS Volume Boosters A Fisher 2625 or 2625NS volume booster (figure 1) is used in conjunction with a positioner on a throttling
More informationRate of Flow Valve Series 120
SPECIFICATIONS Rate of Flow Valve Series DIMENSIONS The OCV Series 120 Rate of Flow control valve is designed to control or limit flow to a predetermined rate, regardless offl uctuations in downstream
More informationPLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions
PLAQUE MFM18240 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM18240... 4 Power Supply Unit MPS061000
More informationARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments
ARCA cabinet NEW High performance polycarbonate cabinet Protection in demanding environments NEW Fibox ARCA Fibox ARCA non corrosive electrical cabinets for use in extremely harsh and demanding environments
More informationData Distribution Cabinets. Exclusive CD edition March 2006
Exclusive CD edition March 2006 Introduction: The development of distribution cabinets is the practical reply from KRONE to the ever increasing demands on the data, telephone, and network technology. Cost-effective,
More informationModel DE-1, VDE-1 and DE-2 Air Release Heads
SPECIFICATIONS Model DE-1, VDE-1 and DE-2 Air Release Heads Bulletin SS03030 Issue/Rev. 0.7 (8/17) Smith Meter Air Eliminator The Smith Meter Model DE Air Release Heads are dual-electric float switch devices
More informationOPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson
Page 1 (6) Our Ref: PSE, Bernt Andersson OPTIPOW 105 OPTIPOW 105, the compact pulse valve for the Optipulse fabric filters of different types: is a result of many years of experiences within the fabric
More informationTECHNICAL MANUAL DHR40 LED. Den Haan Rotterdam MED96/98/EC
TECHNICAL MANUAL DHR40 LED MED96/98/EC SINCE 19 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete
More informationBACK PRESSURE / SUSTAINING
In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.
More informationenclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)
lri030784900.eps lri031083400.eps enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) fri040466500.eps Stainless steel and plastic enclosures for use in potentially explosive
More informationBACK PRESSURE / SUSTAINING
SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series
More informationThe OCV Series 8000 float control valves are designed to maintain a SERIES FEATURES
The OCV Series 8000 float control valves are designed to maintain a desired level in a tank or reservoir by opening for filling the tank when fluid is below the high level point and closing tightly when
More information- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted.
SPECIFICATIONS - All material is solid brass with a #8 mirror finish unless otherwise noted. - All material sold by length is priced in one foot increments. ORDERING PROCEDURE - Use a Purchase Order number.
More informationSUPPLEMENT TO AIRCRAFT FLIGHT MANUAL FOR MOTOR-DRIVEN ROPE WINCH TYPE RPM 11/01
SUPPLEMENT TO AIRCRAFT FLIGHT MANUAL FOR MOTOR-DRIVEN ROPE WINCH TYPE RPM 11/01 (Langenthaler-Winch) Aircraft-Manufacturer: Avions Robin SA Type of Aircraft: Robin DR 300-180R DR400-180R DR 400-200R DR
More informationExtra wide viewing angle from single indicator lamp. Lenses made from polycarbonate and hardened glass. 10mm Panel Hole.
NORDIC N5 Headlamp The N5 integrates head light, indicator and park light in one assembly. This heavy duty light incorporates an adaptable single bolt mount featuring over 1 o of adjustment. ADR compliant
More informationDepth sensor. Product reference : REV 1. USER GUIDE and INSTALLATION GUIDE. nke Sailing competition
Depth sensor Product reference : 90-60-456 REV 1 USER GUIDE and INSTALLATION GUIDE nke Sailing competition Z.I. Kerandré Rue Gutenberg 56700 HENNEBONT- FRANCE http://www.nke.fr After sale service n 33
More informationMounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator
Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering
More informationFisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves
Instruction Manual Lever-Lock Handlever Actuator Fisher Lever Lock Handlever Actuators for POSI SEAL A81 Rotary Valves Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications...
More informationSpecialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions
The Area Value Service Units and Module format (AVSU) provide a local gas isolation facility for use during normal installation and maintenance or in the event of an emergency. They are built in accordance
More informationTECHNICAL MANUAL DHR55N. Den Haan Rotterdam MED96/98/EC
TECHNICAL MANUAL DHR55N MED96/98/EC SINCE 1922 Den Haan Rotterdam DISCLAIMER Despite constant care and attention DHR puts in its manuals it is still possible that information in this manual is incomplete
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION Models No. TD0101, TD0101F Description Impact Driver L PRODUCT P 1/ 14 CONCEPT AND MAIN APPLICATIONS Models TD0101 and TD0101F are cost-competitive 100N.m-class impact driver developed
More information1805 Series Relief Valves
Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion
More informationFlow and check valves Logic valves series 551. Brochure
Flow and check valves Logic valves series 551 Brochure 2 Flow and check valves Logic valves series 551 3/2-directional valve, low pressure operated Qn = 2-120 l/min 3 3/2-directional valve, Qn = 120 l/min
More informationMV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:
MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve
More informationD05T Compact Design Pressure Regulating Valves
D05T Compact Design Pressure Regulating Valves FEATURES PRODUCT DATA Non-corroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass.
More informationDräger HPS 3500 Head Protection System
Dräger HPS 3500 Head Protection System The Dräger HPS 3500 a multifunctional and universal helmet for the diverse requirements of rescue teams during search and rescue, forest and bush fire fighting, traffic
More informationArran LED Floodlight Luminaire
Arran LED Floodlight Luminaire INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment. Good electrical
More information299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012
Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of
More informationSIROCCO. Robust high-pressure diecast aluminium housing. Computer aided design reflector. Graduated scale for accurate aiming.
SIROCCO is a family of floodlight, surface washer and area lighting. Three (3) types of light distribution, asymmetric, bi-symmetric, and road optic. Available in 2 sizes with a range of mounting accessories
More informationOPERATING INSTRUCTIONS
0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0
More informationMasoneilan* 78 Model Air Filter Regulator
GE Oil & Gas Masoneilan* 78 Model Air Filter Regulator Instruction Manual [Rev. D] GE Data Classification : Public THESE INSTRUCTIONS PROVIDE THE CUSTOMER/OPERATOR WITH IMPORTANT PROJECT-SPECIFIC REFERENCE
More information64 Series Pressure Reducing Regulators
Instruction Manual Form 1245 64 Series March 2006 64 Series Pressure Reducing Regulators W1943 Figure 1. 64 Series Regulator Introduction Scope of Manual This manual provides instructions for the installation,
More informationBSS 2 Bottle Sampling System. Instruction manual Version 1.8
BSS 2 Bottle Sampling System Instruction manual Version 1.8 Serial-No.:... Version-/Rev.-Date : 12.06.2012 Contents 1. General... 3 2. Safety Instructions... 4 3. Extent of Delivery... 5 4. Switch Panel...
More informationHAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR DEH SERIES
HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR PASSION TO PERFORM Filter elements are efficient only if their dirt holding capacity is fully exploited. This is achieved by using filter housings equipped
More information