Product Guide. Latitude Series High-Performance Exterior Metal Wall Panels for Horizontal and Vertical Concealed Clip Application

Size: px
Start display at page:

Download "Product Guide. Latitude Series High-Performance Exterior Metal Wall Panels for Horizontal and Vertical Concealed Clip Application"

Transcription

1 Product Guide Latitude Series High-Performance Exterior Metal Wall Panels for Horizontal and Vertical Concealed Clip Application

2 Blank Text (800) Page 2

3 Contents Standard Profile... 4 Clip Interface 12-inch Standard Profile 16-inch Standard Profile Symmetrical Profile inch Symmetrical Profile 16-inch Symmetrical Profile Seam Styles... 6 Z Style Flange C Style Flange Accent Pattern Configuration Examples... 7 Material Selection and Comparison... 8 Testing Summary... 9 ASTM E330 Static Air Pressure (FBC TAS 202) Allowable Negative Wind Pressure, psf ASTM E283 Air Infiltration ASTM E331 Water Infiltration 5 Gallons/Minute per Square Foot ASTM E1886/E1996 Large Missile Impact and Cyclic Air Pressure (FBC TAS 201 & 203) 9 lb. SYP 2x4 at 50 ft./sec. Product Approvals Load Tables Latitude Series Specification Latitude Series Standard Details Parapet Cap Wall Cap Sill Detail at Slab Sill Detail at Curb Outside Corner with Metal Trim Outside Corner with Precision-Edge Miter Inside Corner with Metal Trim Inside Corner with Precision-Edge Miter Window Head Window Sill Window Jamb Soffit Transition Panel End Lap (800) Page 3

4 Standard 4-inch Module The Latitude series is suitable for horizontal and vertical applications. It is available in 12-inch and 16-inch coverage, each creating a 4-inch o.c. pattern in a variety of configurations that can be combined to create dynamic visual impact. 12-inch Standard Symmetrical Profile The standard profile features a symmetrical pattern, with the web elements of each 4-inch module at a consistent 45 o angle to provide aesthtic balance in vertical applications. Precision-edge factory mitered corners are also available. Clip Interface Latitude panels feature a concealed clips, available in 18 gauge galvanized or stainless steel, which accommodate unlimited thermal movement, while providing superior resistance to uplift, and to air and water infiltration. 7/8" 16-inch Standard Symmetrical Profile 57/64" 4" Typ. 119/32" 25/64" 11/8" (800) Page 4

5 Optional Asymmetrical Profile The Latitude series offers an optional asymmetrical profile that, like the standard profile, is available in 12- and 16-inch widths, and a variety of configurations that can be mixed and matched if desired. 12-inch Optional Assymetrical Profile Precision-edge factory mitered corners are also available. LW12A-4 LW12A-18F LW12A-12B LW12A-18B Standard Symmetrical Profile 16-inch Optional Assymetrical Profile LW16A-4 LW16A-18B LW16A-28B LW16A-12B Optional Asymmetrical Profile (800) Page 5

6 Seam Styles Latitude panels are manufactured with one of two concealed flange styles, depending on the material and thickness selected. Z Style Flange The Z-style flange is typically used for the following materials and thicknesses: y Steel 24 gauge 22 gauge y Aluminum y Copper 16 ounce C Style Flange The C-style flange is typically used for the following materials and thicknesses: y Steel 20 gauge 18 gauge y Aluminum y Zinc 0.7 mm 0.8 mm 1.0 mm y Copper 20 ounce 24 ounce (800) Page 6

7 Accent Pattern Configuration Examples LW16A-4 LW16A-4 LW16A-4 4" 4" 8" 4" 4" LW16A-18B LW16A-4 4" 8" 8" 4" LW16A-28B LW16A-4 4" 4" 12" 4" LW16A-12B LW16A-4 LW16A-4 LW16A-4 LW16A-4 4" 4" 8" 4" 4" LW16A-18F LW16A-4 4" 8" 8" 4" LW16A-28F LW16A-4 4" 4" 12" 4" LW16A-12F LW16A-4 (800) Page 7

8 Material Selection and Comparison Steel Aluminum Zinc Copper 24 ga 22 ga 20 ga 18 ga mm 0.8 mm 1.0 mm SEAM 16 oz 20 oz 24 oz Z-style Flange C-style Flange ASTM E-330 ASTM E TESTING ASTM E ASTM E-1886/1996 FBC TAS 201/203 Miami-Dade NOA 2 CLIPS OTHER 18-gauge Galvanized Steel 18-gauge Stainless Steel Standard colors/finishes in stock Thru-fastened Option 1 Air and water infiltration tests were conducted on specimens with field-applied seam sealant 2 Approval pending Minimum panel length = 3-0 Maximum panel length = (800) Page 8

9 Testing Summary ASTM E330 Static Air Pressure (FBC TAS 202) Allowable Negative Wind Pressure, psf Clip Spacing (inches) Gauge Steel " Aluminum mm Zinc Notes: 1. Based on ASTM E330 testing. 2. A safety factor of 1.65 has been applied to the ultimate load at failure. 3. Intermediate values have been interpolated between tested clip spacing. ASTM E283 Air Infiltration 22 Gauge Steel 1.57 PSF 0.05 CFM/SF 6.24 PSF 0.42 CFM/SF ASTM E331 Water Infiltration 5 Gallons/Minute per Square Foot 22 Gauge Steel 2.86 PSF No Leakage 6.24 PSF No Leakage 12.0 PSF No Leakage ASTM E1886/E1996 Large Missile Impact and Cyclic Air Pressure (FBC TAS 201 & 203) 9 lb. SYP 2x4 at 50 ft./sec. 22 Gauge Steel Impact: Panels over 16 GA 36" o.c. - No Rupture. Cyclic Air Pressure: 77 PSF Negative Design Pressure Product Approvals FBC: Pending Miami-Dade: Pending (800) Page 9

10 Load Table: Latitude Series 16" (max. coverage) - 22 Gauge (min.) Steel - Exposure B, I = 1.00, Gcpi = 0.18, roof slope >10 degrees Height Above Ground, feet Zone 4 Maximum On Center Clip Spacing, feet Zone 5 Maximum On Center Clip Spacing, feet Load Table: Latitude Series 16 (max. coverage) - 22 Gauge (min.) Steel - Exposure B, I = 1.15, Gcpi = 0.18, roof slope >10 degrees Height Above Ground, feet Zone 4 Maximum On Center Clip Spacing, feet Zone 5 Maximum On Center Clip Spacing, feet Notes: Panel capacity is based on ASTM E330 testing; A safety factor of 1.65 has been applied to the ultimate load at failure; Intermediate values have been interpolated between tested clip spacing; Wind pressure calculation is based on ASCE 7-05 Method 2. (800) Page 10

11 Load Table: Latitude Series 16" (max. coverage) - 22 Gauge (min.) Steel - Exposure C, I = 1.00, Gcpi = 0.18, roof slope >10 degrees Height Above Ground, feet Zone 4 Maximum On Center Clip Spacing, feet Zone 5 Maximum On Center Clip Spacing, feet Load Table: Latitude Series 16 (max. coverage) - 22 Gauge (min.) Steel - Exposure C, I = 1.15, Gcpi = 0.18, roof slope >10 degrees Height Above Ground, feet Zone 4 Maximum On Center Clip Spacing, feet Zone 5 Maximum On Center Clip Spacing, feet Notes: Panel capacity is based on ASTM E330 testing; A safety factor of 1.65 has been applied to the ultimate load at failure; Intermediate values have been interpolated between tested clip spacing; Wind pressure calculation is based on ASCE 7-05 Method 2. (800) Page 11

12 Load Table: Latitude Series 16" (max. coverage) (min.) Aluminum - Exposure B, I = 1.00, Gcpi = 0.18, roof slope >10 degrees Height Above Ground, feet Zone 4 Maximum On Center Clip Spacing, feet Zone 5 Maximum On Center Clip Spacing, feet Load Table: Latitude Series 16 (max. coverage) (min.) Aluminum - Exposure B, I = 1.15, Gcpi = 0.18, roof slope >10 degrees Height Above Ground, feet Zone 4 Maximum On Center Clip Spacing, feet Zone 5 Maximum On Center Clip Spacing, feet Notes: Panel capacity is based on ASTM E330 testing; A safety factor of 1.65 has been applied to the ultimate load at failure; Intermediate values have been interpolated between tested clip spacing; Wind pressure calculation is based on ASCE 7-05 Method 2. (800) Page 12

13 Load Table: Latitude Series 16 (max. coverage) (min.) Aluminum - Exposure C, I = 1.00, Gcpi = 0.18, roof slope >10 degrees Height Above Ground, feet Zone 4 Maximum On Center Clip Spacing, feet Zone 5 Maximum On Center Clip Spacing, feet Load Table: Latitude Series 16 (max. coverage) (min.) Aluminum - Exposure C, I = 1.15, Gcpi = 0.18, roof slope >10 degrees Height Above Ground, feet Zone 4 Maximum On Center Clip Spacing, feet Zone 5 Maximum On Center Clip Spacing, feet Notes: Panel capacity is based on ASTM E330 testing; A safety factor of 1.65 has been applied to the ultimate load at failure; Intermediate values have been interpolated between tested clip spacing; Wind pressure calculation is based on ASCE 7-05 Method 2. (800) Page 13

14 Load Table: Latitude Series 16" (max. coverage) - 0.8mm (min.) Zinc - Exposure B, I = 1.00, Gcpi = 0.18, roof slope >10 degrees Height Above Ground, feet Zone 4 Maximum On Center Clip Spacing, feet Zone 5 Maximum On Center Clip Spacing, feet Load Table: Latitude Series 16 (max. coverage) - 0.8mm (min.) Zinc - Exposure B, I = 1.15, Gcpi = 0.18, roof slope >10 degrees Height Above Ground, feet Zone 4 Maximum On Center Clip Spacing, feet Zone 5 Maximum On Center Clip Spacing, feet Notes: Panel capacity is based on ASTM E330 testing; A safety factor of 1.65 has been applied to the ultimate load at failure; Intermediate values have been interpolated between tested clip spacing; Wind pressure calculation is based on ASCE 7-05 Method 2. (800) Page 14

15 Load Table: Latitude Series 16 (max. coverage) - 0.8mm (min.) Zinc - Exposure C, I = 1.00, Gcpi = 0.18, roof slope >10 degrees Height Above Ground, feet Zone 4 Maximum On Center Clip Spacing, feet Zone 5 Maximum On Center Clip Spacing, feet Load Table: Latitude Series 16 (max. coverage) - 0.8mm (min.) Zinc - Exposure C, I = 1.15, Gcpi = 0.18, roof slope >10 degrees Height Above Ground, feet Zone 4 Maximum On Center Clip Spacing, feet Zone 5 Maximum On Center Clip Spacing, feet Notes: Panel capacity is based on ASTM E330 testing; A safety factor of 1.65 has been applied to the ultimate load at failure; Intermediate values have been interpolated between tested clip spacing; Wind pressure calculation is based on ASCE 7-05 Method 2. (800) Page 15

16 Blank Text (800) Page 16

17 Latitude Series Specification SECTION PREFORMED METAL WALL PANELS This specification is applicable for IMETCO LATITUDE concealed clip metal wall panel system. 1.0 GENERAL. 1.1 DESCRIPTION. **Modify as necessary** A. Work described in this section includes preformed metal wall panel system complete with clips, perimeter and penetration flashing, closures, gutters, and downspouts. B. Related work specified elsewhere: 1. Structural steel. 2. Steel joists, girts, and stud walls. 3. Metal fabrications. 4. Rough carpentry. 5. Insulation. 6. Flashing and sheet metal. (Not wall panel related). 7. Vapor barrier. 8. Insulation. 1.2 SUBMITTALS. A. Shop drawings: Show wall panel system with flashings and accessories in plan and elevation; sections and details. Include metal thicknesses and finishes, panel lengths, joining details, anchorage details, flashings and special fabrication provisions for termination and penetrations. Indicate relationships with adjacent and interfacing work. Shop drawings to be prepared by metal wall panel manufacturer. B. Warranty: Provide unexecuted specimen warranty documents for each warranty as required in specification section 1.7. C. Samples. 1. Submit sample of panel section, at least 6 x 6 showing seam profile and also a sample of color selected. 2. Submit sample of panel clip. 1.3 DELIVERY, STORAGE, AND HANDLING. A. Inspect materials upon delivery. B. Handle materials to prevent damage. C. Store materials off ground providing for drainage; under cover providing for air circulation; and protected from any debris. 1.4 REFERENCE STANDARDS. A. American Iron and Steel Institute (AISI): 1. SG02-1: 2001 Edition of the North American Specification for the Design of Cold-Formed Steel Structural Members. B. American Society for Testing and Materials (ASTM): 1. A653-09: Specification for Steel Sheet, Zinc-coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by thehot-dip Process. 2. A792-09: Specification for Steel Sheet, 55% Aluminum-Zinc Alloy-Coated by the Hot-Dip Process. 3. B69-08: Standard Specification for Rolled Zinc. 4. B209-07: Specification for Aluminum and Aluminum-Alloy Sheet and Plate. 5. D : Specification for Flexible Cellular Materials Sponge or Expanded Rubber. 6. D : Test Method for Flexible Cellular Materials made from Olefin Polymers. 7. E283-04: Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. 8. E330-02: Standard Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference. 9. E (2009): Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference. 10. E : Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials. C. Sheet Metal and Air Conditioning Contractors National Association (SMACNA): 1. Architectural Sheet Metal Manual, 5th edition. 1.5 QUALITY CRITERIA. A. Engage an experienced metal wall panel contractor (erector) to install wall panel system who has a minimum of three (3) years experience specializing in the installation of metal wall panel systems. B. Contractor must be certified by manufacturer specified as supplier of metal wall panel system and obtain written certification from manufacturer that installer is approved for installation of specified system. C. Successful contractor must obtain all components of wall panel system from a single manufacturer. Any secondary products that are required which cannot be supplied by the specified manufacturer must be recommended and approved in writing by primary manufacturer prior to bidding. D. Fabricator/Installer shall submit work experience and evidence of adequate financial responsibility. Architect reserves the right to inspect fabrication facilities in determining qualifications. E. Applicable erection tolerances: Maximum variation from true planes or lines: 1/4 in 20-0 ; 3/8 in 40-0 or more. 1.6 DESIGN AND PERFORMANCE CRITERIA. A. Thermal movement: 1. Interface between panel and clip shall provide for unlimited thermal movement in each direction along the longitudinal direction. 2. Location of metal wall panel rigid connector shall be designed, per job condition, by the wall panel system manufacturer. (800) Page 17

18 B. Uniform Wind Load Capacity. 1. Installed wall panel system shall withstand positive and negative wind pressures complying with the following criteria. a. Design Code: ASCE 7, Method 2 for Components and Cladding. b. Safety Factor: The panel system shall withstand a proof load equal to 150% of the design wind pressure, as per the ASTM E330 testing standard. c. Category **Select**<I, II, III, or IV> Building with an Importance Factor of **Select**<0.77, 1.00, or 1.15>. d. Wind Speed: mph. e. Exposure Category: **Select**<B, C, or D>. f. Maximum Wall Height: feet. g. Minimum Building Width: feet. h. Roof Pitch: inches per foot. Design Wind Pressure: Zone 4 - Field of Wall: + psf and - psf Zone 5 - Building Corners: + psf and - psf 2. Capacity shall be determined using defined method in accordance with ASTM E330. C. Air infiltration: The panel system shall be tested in accordance with ASTM E283, and meet or exceed the following performance requirements: Pressure Area Leakage Rate 1.57 PSF > 0.06 cfm/sq.ft. D. Static air pressure water infiltration: The panel system shall be tested in accordance with ASTM E331, and meet or exceed the following performance requirements: Pressure Result 5 Gal/Hr per S.F. and Static Air No Leakage Pressure of 12.0 psf for 15 minutes E. Missile Impact Test and Cyclic Wind Pressure Test: The panel system shall be tested in accordance with ASTM E1886 and E1996 <or FBC Test Protocols TAS 201 and TAS 203>. 1.7 WARRANTIES. A. Endorse and forward to owner the following warranties: year limited waterrtight warranty, jointly signed by the installer and the manufacturer. 2. Manufacturer s standard 20 year finish warranty covering checking, crazing, peeling, chalking, fading, and adhesion. 3. Installer s 2 year warranty covering wall panel system installation and watertightness. B. Warranties shall commence on date of substantial completion. 2.0 PRODUCTS. 2.1 METAL WALL PANEL SYSTEM. A. Panel shall be Imetco LATITUDE Wall system as manufactured by Innovative Metals Company, Inc. (Imetco), Tucker, Georgia, telephone B. Alternate manufacturers are subject to full compliance with specification requirements, and shall be submitted for approval as follows: 1. Manufacturers not listed above must submit for approval, ten (10) days prior to bid date, the following: Manufacturer s literature; certification of testing in accordance with specification requirements and sections 1.2 and 1.6; sample warranties in accordance with specification section 1.7; installer qualifications in accordance with specification section 1.5, and a list of five (5) similar projects in size and scope of work. 2. No substitutions will be permitted after the bid date of this project. C. Materials. 1. Panel materials: **Select Material** [24 or 22 or 20] gauge G90 galvanized steel, per ASTM A653 or AZ50 Galvalume steel, per ASTM A792 or [0.032 or or or ] aluminum, 3105-H14 aluminum alloy, per ASTM B209 or [0.7 mm or 0.8 mm or 1.0 mm] rolled zinc, Type 710, per ASTM B Flashing and flat stock material: Fabricate in profiles indicated on drawings of same material, thickness, and finish as wall panel system, unless indicated otherwise. **If Specifying Mill Finish Panels, Delete the Following Section** D. Finish on exposed surfaces. 1. Two coat coil applied, baked-on full-strength (70% resin) fluorocarbon coating system (polyvinylidene fluoride, PVF2), applied by manufacturer s approved applicator. 2. Coating system shall provide nominal 1.0 mil dry film thickness, consisting of primer and color coat. **Select Appropriate Color Option Below** a. Color shall be Imetco s. b. Color shall be selected from Imetco s Standard Colors. c. Color: Custom color selected by architect. d. Color shall be:. e. Zinc panels shall be furnished United Zinc preweathered Glacier Gray. 3. Unexposed surfaces of painted steel or aluminum materials shall be baked-on polyester coating with mil total dry film thickness (TDF). 4. Unexposed surface of Zinc panels shall be 5 mil minimum plastisol high performance coating system. **If Specifying Painted Panels, Delete the Following Section** (note: G90 galvanized material is only provided as a painted product) E. Finish on exposed and unexposed surfaces shall be bare, as delivered from the mill. F. Characteristics. 1. Fabrication: Panels shall be factory formed from specified metal. 2. Profiles shall be as indicated project drawings. a. The standard profile shall provide ribs at 4 on center. b. Alternate profile panels shall be used to provide reveals of single 8, double 8, or 12 accent bands as shown on project drawings. c. Web elements of the ribs shall be [asymmetrical or symmetrical] angle. 3. Panel orientation: [Horizontal or Vertical]. (800) Page 18

19 4. Configuration: Panel shall be [12 or 16 ] wide (nominal) with interlocking seams incorporating concealed anchor clips allowing thermal movement. 5. Panel Depth (Concealed Leg Height): 7/8 (nominal). 6. Anchor clips: Clips shall be 18 gauge galvanized steel designed to allow thermal movement of the panel in each direction along the longitudinal dimension. 7. Panel length: Up to 20 feet maximum length. G. Accessories. 1. Fasteners. Blank Text a. Concealed fasteners: Corrosion resistant steel screws, #14 x length appropriate for substrate, hex washer head. Use self-drilling, self-tapping for metal substrate or A-point for plywood substrate. b. Exposed fasteners: 300 series stainless steel screws (cadmium or zinc coatings are not acceptable) with neoprene sealing washer, or 1/8 diameter stainless steel rivets. 2. Sealants: Tripolymer or polyurethane sealant shall be field applied by installer in all panel seams, terminations, and penetrations. 3. Foam closures for inside corners, outside corners, door and window jambs, and batten reveal terminations: Factory precut closed cell foam meeting ASTM D1056 and/or D Precision Edge mitered corners: inside and outside corners shall be factory mitered and permanently joined from prefinished materials. 5. Provide all miscellaneous accessories for complete installation. 2.2 ACCESSORY PRODUCTS. A. Sealant. 1. Acceptable product. a. Concealed Application: Non-curling butyl sealant or equal. b. Exposed Application: Tripolymer or polurethane sealant or equal. c. Colors: As selected by architect from manufacturer s standard selection. B. Underlayment. 1. Underlayment shall be applied over entire wall substrate area. 2. Underlayment shall be one layer of 40 mil (minimum) self adhering bituminous waterproofing membrane. Seams shall be lapped in accordance with manufacturer s recommendations. 2.3 FABRICATION. A. Shop fabricate metal wall panels and flashing components to the maximum extent possible, forming metal work with clear, sharp, straight, and uniform bends and rises. Hem exposed edges of flashings. B. Form flashing components from full single width sheet in minimum 10-0 sections. Provide shop fabricated, mitered corners, joined using closed end pop rivets and joint sealant. C. Fabricate wall panels and related sheet metal work in accordance with approved shop drawings and applicable standards. 3.0 EXECUTION. 3.1 PREPARATION. A. Inspection: Examine the alignment and placement of the building structure and substrate. B. Correct any objectionable warp, waves or buckles in the substrate before proceeding with installation of the preformed metal wall panels. 3.2 WALL PANEL AND FLASHING INSTALLATION. A. Install wall panels and flashings in accordance with approved shop drawings and manufacturer s product data, within specified erection tolerances. B. Isolate dissimilar metals and masonry or concrete from metals with bituminous coating. Use gasketed fasteners where required to prevent corrosive action between fastener, substrate, and panels. C. Limit exposed fasteners to extent indicated on shop drawings. D. Anchorage shall allow for temperature expansion/contraction movement without stress or elongation of panels, clips, or anchors. Attach clips to substrate using fasteners of size and spacing as determined by manufacturer s design analysis to resist specified wind pressure and thermal movement forces. E. Seal laps and joints in accordance with wall panel system manufacturer s product data. F. Coordinate flashing and sheet metal work to provide weathertight conditions at wall panel terminations. Fabricate and install in accordance with standards of SMACNA Manual. G. Provide for temperature expansion/contraction movement of panels at wall panel penetrations and wall panel mounted equipment, in accordance with system manufacturer s product data and design calculations. H. Installed system shall be true to line and plane and free of dents, and physical defects. I. Form joints in linear sheet metal to allow for 1/4 minimum expansion at 20-0 o.c. maximum and 8-0 from corners. J. At joints in linear sheet metal items, set sheet metal items in two 1/4 beads of butyl sealant. Extend sealant over all metal surfaces. Mate components for positive seal. Allow no sealant to migrate onto exposed surfaces. K. Clean exposed surfaces of wall panels and accessories after completion of installation. Leave in clean condition at date of substantial completion. Touch up minor abrasions and scratches in finish. END OF SECTION (800) Page 19

20 Blank Text (800) Page 20

21 Latitude Series Standard Details Parapet Cap Wall Cap Sill Detail at Slab Sill Detail at Curb Outside Corner with Metal Trim Outside Corner with Precision-Edge Miter Inside Corner with Metal Trim Inside Corner with Precision-Edge Miter Window Head Window Sill Window Jamb Soffit Transition Panel End Lap... 34, 35 (800) Page 21

22 Parapet Cap (800) Page 22

23 Wall Cap (800) Page 23

24 Sill Detail at Slab (800) Page 24

25 Sill Detail at Curb (800) Page 25

26 Outside Corner with Metal Trim (800) Page 26

27 Outside Corner with Precision-Edge Miter (800) Page 27

28 Inside Corner with Metal Trim (800) Page 28

29 Inside Corner with Precision-Edge Miter (800) Page 29

30 Window Head (800) Page 30

31 Window Sill (800) Page 31

32 Window Jamb (800) Page 32

33 Soffit Transition (800) Page 33

34 Product Guide: Latitude Series Metal Wall Panels Panel End Lap (800) Page 34

35 Panel End Lap (800) Page 35

36 2070 Steel Drive Tucker, GA (800) Copyright 2009, Innovative Metals Company, Inc.

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION SHOWER AND BATH ENCLOSURES. Display hidden notes to specifier by using Tools / Options / View / Hidden Text. SECTION 10185 SHOWER AND BATH ENCLOSURES Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Bathtub wall enclosures. B. Shower wall

More information

PERFORMANCE TEST REPORT FOR AIR LEAKAGE AND DURABILITY OF BARRIER PRODUCTS ASTM E Rendered to: BAUTEX SYSTEMS

PERFORMANCE TEST REPORT FOR AIR LEAKAGE AND DURABILITY OF BARRIER PRODUCTS ASTM E Rendered to: BAUTEX SYSTEMS Architectural Testing PERFORMANCE TEST REPORT FOR AIR LEAKAGE AND DURABILITY OF BARRIER PRODUCTS ASTM E 2357 Rendered to: BAUTEX SYSTEMS SERIES/MODEL: AMB 20-WN PRODUCT TYPE: Air Barrier System Report

More information

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL SECTION 10801 - TOILET AND BATH ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions apply to this Section.

More information

TESTING APPLICATION STANDARD (TAS)

TESTING APPLICATION STANDARD (TAS) TESTING APPLICATION STANDARD (TAS) No. 00(A)-9 TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE AND/OR INCREASED WINDSPEED RESISTANCE OF SOFFIT VENTILATION STRIP AND CONTINUOUS OR INTERMITTENT VENTILATION

More information

1. Section Summary for loose climbing equipment provided by Owner. 2. Section "Cast in Place Concrete"

1. Section Summary for loose climbing equipment provided by Owner. 2. Section Cast in Place Concrete SECTION 131200 CLIMBING WALLS PART 1 - GENERAL 1.1 SUMMARY A. Work included: 1. Provide seamless textured substrate, panel-formed interior climbing wall system with internal structural support system,

More information

VICTORIAN AND CLASSIC SHINGLES INSTALLATION DETAILS BERRIDGE MANUFACTURING COMPANY

VICTORIAN AND CLASSIC SHINGLES INSTALLATION DETAILS BERRIDGE MANUFACTURING COMPANY VICTORIAN AND S INSTALLATION DETAILS MANUACTURING 800-669-0009 www.berridge.com INDEX INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS INTRODUCTION TO TYPICAL DETAILS OVERVIEW

More information

CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division

CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division 5023 HAZEL JONES ROAD, BOSSIER CITY, LA 71111 888.315.1561 800.877.8746 FAX SALES@GORDONCLEANROOM.COM GORDONCLEANROOM.COM AN EMPLOYEE OWNED COMPANY CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division

More information

Section GATE VALVES

Section GATE VALVES Section 02521 PART 1 GENERAL 1.01 SUMMARY This Section includes the furnishing and installation of gate valves for isolation and dead-end service as shown on Plans and as specified herein. 1.02 MEASUREMENT

More information

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A STRUCTURAL PERFORMANCE TEST REPORT SUMMARY RENDERED TO:

AAMA/WDMA/CSA 101/I.S.2/A AAMA/WDMA/CSA 101/I.S.2/A STRUCTURAL PERFORMANCE TEST REPORT SUMMARY RENDERED TO: AAMA/WDMA/CSA 101/I.S.2/A440-05 AAMA/WDMA/CSA 101/I.S.2/A440-08 STRUCTURAL PERFORMANCE TEST REPORT SUMMARY RENDERED TO: ALL SEASONS DOOR & WINDOW, INC. 28 EDGE ROAD EAST BRUNSWICK, NJ 08816 MODEL/ A-200

More information

LATICRETE International Inc. One LATICRETE Park North Bethany, CT USA

LATICRETE International Inc. One LATICRETE Park North Bethany, CT USA EVALUATION OF FRAMED WALL CONSTRUCTION SECTIONS UTILIZING LATICRETE INTERNATIONAL S LATICRETE BUILDING ENVELOPE SYSTEM AIR BARRIER SYSTEM IN ACCORDANCE WITH CAN/ULC S742-11 Report to: LATICRETE International

More information

for Cold-Formed Steel Framing Products

for Cold-Formed Steel Framing Products Technical Guide for Cold-Formed Steel Framing Products Technical Data in this publication is applicable to the following SFIA Member Company: For a complete directory of SFIA Members who are certified

More information

Summit Anchor Company, Inc.

Summit Anchor Company, Inc. Summit Anchor Company, Inc. Safety From The Top Down Roof and Wall Safety/Tie-Back Anchors Suspended Access Systems and Fall Protection Overview United States and Canadian national safety standards require

More information

ASTM E1886 and ASTM E1996 TEST REPORT. Report No.: E Rendered to: 3M COMPANY St. Paul, Minnesota 55144

ASTM E1886 and ASTM E1996 TEST REPORT. Report No.: E Rendered to: 3M COMPANY St. Paul, Minnesota 55144 ASTM E1886 and ASTM E1996 TEST REPORT Report No.: E6587.01 201 44 Rendered to: 3M COMPANY St. Paul, Minnesota 55144 PRODUCT TYPE: Safety and Security Window Film SERIES/MODEL: 3M Safety and Security Film

More information

provides an increased stiffness and strength compared with standard cee studs, resulting in lighter headers which require less labor to install.

provides an increased stiffness and strength compared with standard cee studs, resulting in lighter headers which require less labor to install. CURTAIN WALL SYSTEMS HEADER/SILL SOLUTIONS JAMSTUD HEADER/SILL ASSEMBLY VALUE delivers exceptional value when utilized as part of a header or sill assembly. s unique shape allows for the design and construction

More information

SECTION BUTTERFLY VALVES

SECTION BUTTERFLY VALVES SECTION 15112 BUTTERFLY VALVES PART 1 GENERAL 1.01 SUMMARY A. All butterfly valves shall be of the tight closing, rubber seated type and fully comply with the latest revision of AWWA Standard C504, Class

More information

NUWALL METAL WALL PANEL METL-SPAN CONCEALED FASTENER SINGLE-SKIN PANELS

NUWALL METAL WALL PANEL METL-SPAN CONCEALED FASTENER SINGLE-SKIN PANELS NUWALL METAL WALL PANEL NuWall combines the ease of installation in both new and retrofit applications with the pleasing aesthetic appeal of a clean, uninterrupted wall. For retrofit construction, all

More information

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS (Patent Pending) WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT

More information

INSTALLATION & OPERATION MANUAL AORCS ATLAS OPERATING ROOM CEILING SYSTEM. Redefine your comfort zone.

INSTALLATION & OPERATION MANUAL AORCS ATLAS OPERATING ROOM CEILING SYSTEM. Redefine your comfort zone. INSTALLATION & OPERATION MANUAL AORCS ATLAS OPERATING ROOM CEILING SYSTEM IOM AORCS ATLAS OPERATING ROOM CEILING SYSTEM Table of Contents Inspection...3 Examination...3 Preparation...3 Installation...4

More information

Now with SUPREME FRAMING SYSTEM! PRODUCT TECHNICAL GUIDE. Steel Stud Manufacturers Association

Now with SUPREME FRAMING SYSTEM! PRODUCT TECHNICAL GUIDE. Steel Stud Manufacturers Association Now with SUPREME FRAMING SYSTEM! PRODUCT TECHNICAL GUIDE Steel Stud Manufacturers Association 2507 3064P Product Identification "S" and "SFS" - C-STUD/JOIST S and SFS-SECTIONS* * For "S" and "SFS" members,

More information

INTRODUCTION. Disclaimer

INTRODUCTION. Disclaimer 3 INTRODUCTION The Steel Framing Industry Association (SFIA) was formed with the objective of assisting companies having interests in the cold-formed steel framing industry to be more successful by unifying

More information

Precision Duct Systems 4570 Commerce Cir SW Atlanta, GA Phone (404)

Precision Duct Systems 4570 Commerce Cir SW Atlanta, GA Phone (404) Project Name: Engineer: Contractor: Section Number: Date Submitted: Date Approved: Pressure Class: Material Type: Connections: 2005 Up to 10 wg 1995 2 wg pos 1995 4 wg pos 1995 10 wg 2005 neg WG: 1995

More information

MIL-STD-883H METHOD EXTERNAL VISUAL

MIL-STD-883H METHOD EXTERNAL VISUAL * EXTERNAL VISUAL 1. PURPOSE. The purpose of this test method is to verify the workmanship of hermetically packaged devices. This test method shall also be utilized to inspect for damage due to handling,

More information

LPCorp.com

LPCorp.com T R E A T E D E N G I N E E R E D W O O D C L A D D I N G E N G I N E E R E D F O R C O M M E R C I A L A P P L I C A T I O N S LPCorp.com 888.820.0325 1 LAP & SIDING CEDAR TEXTURE LAP The bold look of

More information

This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or

This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or This program is registered with the AIA/CES for continuing professional education. As such, it does not include content that may be deemed or construed to be an approval or endorsement by the AIA of any

More information

for Cold-Formed Steel Framing Products

for Cold-Formed Steel Framing Products Technical Guide for Cold-Formed Steel Framing Products The data in this guide is based upon the 2007 American Iron and Steel Institute s S00-07 North American Specification for the Design of Cold-Formed

More information

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT NOR-LAKE, INCORPORATED 800-955-5253 727 Second Street 715-386-2323 P.O. Box 248 866-961-5253 Parts Hudson, Wisconsin 54016 800-388-5253 Service 715-386-4290 FAX www.norlake.com Kold locker WalK-Ins Standard

More information

S Surge Arresters

S Surge Arresters Surge Arresters UltraSIL Polymer-Housed VariSTAR Type US, UH, and UX Station-Class Surge Arresters Installation and Maintenance Instructions Service Information S235-88-1 Contents Product Information...........................1

More information

EVALUATION SUBJECT: SPUNSTRAND STANDARD AND INSULATED UNDERSLAB DUCTS

EVALUATION SUBJECT: SPUNSTRAND STANDARD AND INSULATED UNDERSLAB DUCTS ICC-ES Report ESR-1681 Reissued 12/2017 This report is subject to renewal 12/2018 EVALUATION SUBJECT: SPUNSTRAND STANDARD AND INSULATED UNDERSLAB DUCTS DIVISION: 23 00 00 HEATING, VENTILATING AND AIR CONDITIONING

More information

SPIRAL PIPE - OVAL SINGLE WALL

SPIRAL PIPE - OVAL SINGLE WALL SPIRAL PIPE - OVAL SINGLE WALL Duct Direct Pipe and Fittings are manufactured in accordance with 2005 SMACNA Duct Construction Standards (1995 SMACNA Standards on request) OVAL SUBMITTAL Oval Single Wall

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Sample Procurement Specifications for Aluminum Traffic Control Signs and Components

Sample Procurement Specifications for Aluminum Traffic Control Signs and Components Sample Procurement Specifications for Aluminum Traffic Control Signs and Components These sample procurement Specifications were prepared by the American Traffic Safety Services Association (ATSSA) Sign

More information

REPORT HOLDER: FRAMECAD LICENSING LTD. POST OFFICE BOX 1292 AUCKLAND 1140 NEW ZEALAND EVALUATION SUBJECT: COLD FORMED STEEL C SHAPES AND TRACKS

REPORT HOLDER: FRAMECAD LICENSING LTD. POST OFFICE BOX 1292 AUCKLAND 1140 NEW ZEALAND EVALUATION SUBJECT: COLD FORMED STEEL C SHAPES AND TRACKS 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2361 Reissued 05/2017 This report is subject to renewal 05/2019. DIVISION: 05 00

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

ADDENDUM NO. 3 TO THE BIDDING DOCUMENTS FOR UNIVERSITY OF ILLINOIS COLLEGE OF MEDICINE PEORIA INTERIOR RENOVATIONS

ADDENDUM NO. 3 TO THE BIDDING DOCUMENTS FOR UNIVERSITY OF ILLINOIS COLLEGE OF MEDICINE PEORIA INTERIOR RENOVATIONS ADDENDUM NO. 3 TO THE BIDDING DOCUMENTS FOR UNIVERSITY OF ILLINOIS COLLEGE OF MEDICINE PEORIA INTERIOR RENOVATIONS DATE: October 10 TH 2016 TO ALL BIDDERS BIDDING ON THE ABOVE PROJECT: All Bidders submitting

More information

SECTION [ ] [02730] STABILIZED DECOMPOSED GRANITE SURFACING

SECTION [ ] [02730] STABILIZED DECOMPOSED GRANITE SURFACING SECTION [32 15 40] [02730] STABILIZED DECOMPOSED GRANITE SURFACING EDIT SPECIFICATION: Edit the following guide specification to comply with project requirements. This document is available in word processing

More information

6.0 ENGINEERING. Build Anything Better. REPRINTED 2017

6.0 ENGINEERING. Build Anything Better.  REPRINTED 2017 6.0 ENGINEERING TABLE OF CONTENTS 6.1 U.S. ENGINEERING ANALYSIS REPORT... P. 6-3 BELOW-GRADE WALL REINFORCEMENT TABLES... P. 6-5 ABOVE-GRADE WALL REINFORCEMENT TABLES.. P. 6-21 LINTEL REINFORCEMENT TABLES...P.

More information

Product Identification

Product Identification Product Identification All SCAFCO products have a four part identification code which identifies the size (both depth and flange width), style, and material thickness of each member. Example: Member Depth:

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Water Management Residential Podium Construction BSC Experts Session Overview. Overview

Water Management Residential Podium Construction BSC Experts Session Overview. Overview Building Science Experts' Seminar Water Management Residential Podium December 11-12, 2013 Peter Baker, P.Eng. Water Management Residential Podium BSC Experts Session 2013 Overview Building Enclosure Commissioning

More information

NO LAKE. Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

NO LAKE. Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 dinecompany.com 800-955-5253 715-386-2323 800-388-5253 Parts 715-386-4291 FAX www.norlake.com NO LAKE KOLD LOCKER WALK-INS

More information

Check with local zoning official for property line distance requirements.

Check with local zoning official for property line distance requirements. RESIDENTIAL POOL PLAN SUBMITTAL GUIDELINES The following guidelines are intended to assist municipal residents with the permit acquisition process with regard to pools, spas and hot tubs for single family

More information

RESIDENTIAL BUILDING PLAN REVIEW CHECKLIST

RESIDENTIAL BUILDING PLAN REVIEW CHECKLIST RESIDENTIAL BUILDING PLAN REVIEW CHECKLIST PERMIT # THREE (3) SETS OF PLANS REQUIRED. ONE (1) SET OF DIGITAL PLANS REQUIRED FOR ALL NEW STRUCTURES Plans Examiner: Date: Owner: Permit #: Contractor: Phone

More information

Made in U.S.A. Narrow-U Bike Rack Heavy Duty Submittal Sheet. Materials: Finishes: Mount Options: Setbacks:

Made in U.S.A. Narrow-U Bike Rack Heavy Duty Submittal Sheet. Materials: Finishes: Mount Options: Setbacks: Submittal Sheet Materials: 2 Schedule 40 Steel Pipe (2.375 OD) Finishes: Galvanized An after fabrication hot dipped galvanized finish is available Powder Coat Our powder coat finish assures a high level

More information

USG Ceiling Solutions. LOGIX Integrated Ceiling Systems INSTALLATION GUIDE

USG Ceiling Solutions. LOGIX Integrated Ceiling Systems INSTALLATION GUIDE USG Ceiling Solutions LOGIX Integrated Ceiling Systems INSTALLATION GUIDE LOGIX Integrated Ceiling Systems INSTALLATION GUIDE Logix Brand Integrated Ceiling Systems integrated ceiling systems from USG

More information

Originally Issued: 10/08/2010 Revised: 10/27/2017 Valid Through: 10/31/2018

Originally Issued: 10/08/2010 Revised: 10/27/2017 Valid Through: 10/31/2018 ITW BUILDING COMPONENTS GROUP INC. ITW ALPINE HANGERS AND ANCHORS CSI Section: 06 05 23 Wood, Plastic and Composite Fastenings 1.0 RECOGNITION ITW Alpine Hangers and Anchors recognized in this report has

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

TorqBolt Wedge Anchors Torque Controlled Expansion Anchor

TorqBolt Wedge Anchors Torque Controlled Expansion Anchor TorqBolt Wedge Anchors Torque Controlled Expansion Anchor Product Description The Torqbolt wedge anchor is a torque-controlled, wedge expansion anchor for heavy duty fastening applications where high pull

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Operations and Instruction Manual Might Swivel Model # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

Operations and Instruction Manual Might Swivel Model # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn Operations and Instruction Manual Might Swivel Model # 00238 Concrete and Steel Anchorage Connector ANSI Z359.1 10,000 lbs / 44kn Description: Zinc plated forged heat treated steel, Special design gives

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

Ford Service Saddles and Tapping Sleeves

Ford Service Saddles and Tapping Sleeves Section AA 5/2001 Ford Service Saddles and Tapping Sleeves The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 219/563-3171 FAX: 1-800-826-3487

More information

Moai Bike Rack Heavy Duty Submittal Sheet. Materials: 2.0 Schedule 40 Pipe (2.375 OD) Finishes: Capacity: Mount Options: Setbacks: 2 Bikes

Moai Bike Rack Heavy Duty Submittal Sheet. Materials: 2.0 Schedule 40 Pipe (2.375 OD) Finishes: Capacity: Mount Options: Setbacks: 2 Bikes Submittal Sheet Materials: 2.0 Schedule 40 Pipe (2.375 OD) Finishes: Galvanized An after fabrication hot dipped galvanized finish is available. Powder Coat Our powder coat finish assures a high level of

More information

Liquefied gas cargo tanks and process pressure vessels

Liquefied gas cargo tanks and process pressure vessels .1 -.3 Liquefied gas cargo tanks and process pressure vessels.1 General.1.1 The present texts give the general principles which are applied by Classification Societies for approval and survey of the relevant

More information

Installation and Operation Instruction Manual

Installation and Operation Instruction Manual Installation and Operation Instruction Manual Toggle Lok Anchor - Model #7442 Portable Concrete Anchorage Connector ANSI Z359.1 5,000 lbs / 22.24 kn FallTech, Inc 1306 Alameda Street Compton, CA 90221

More information

Roughneck TM Mesh Slings

Roughneck TM Mesh Slings Roughneck TM Slings ROUGHNECK WIRE MESH SLINGS Widely used in metalworking shops and steel warehouses where loads are abrasive, hot or tend to cut web slings Features and Benefits Promotes Safety Steel

More information

SECTION SWIMMING POOLS

SECTION SWIMMING POOLS SECTION 13 1100 SWIMMING POOLS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pool shell. 2. Pool mechanical system. 3. Pool heating system. 4. Interior pool finish. 5. Final testing and demonstration

More information

1688 Jean-Berchmans-Michaud Drummondville, Quebec. J2C 8E9. Mr. Marc-Etienne Mathieu,ing.

1688 Jean-Berchmans-Michaud Drummondville, Quebec. J2C 8E9. Mr. Marc-Etienne Mathieu,ing. EVALUATION OF FRAMED WALL CONSTRUCTION SECTIONS UTILIZING SOPREMA S SOPRASEAL STICK 1100T SELF-ADHERED AIR BARRIER SYSTEM IN ACCORDANCE WITH CAN/ULC S742-11 Report to: Soprema 1688 Jean-Berchmans-Michaud

More information

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product:

1.3 LIMITATIONS: The following application limitations must be recognized and considered before using this product: 3965 Pepin Avenue Red Wing, MN 55066-1837 Toll Free: (800) 328-6146 Phone: (651) 388-8282 Fax: (651) 388-5065 www.protecta.com User Instruction Manual AJ720A Concrete Anchor This manual is intended to

More information

SECTION FACILITY FALL PROTECTION PART I - GENERAL

SECTION FACILITY FALL PROTECTION PART I - GENERAL SECTION 11 24 29 - FACILITY FALL PROTECTION PART I - GENERAL 1.1 The Illinois Department of Labor (IDOL) regulates fall protection for general industry and construction in the public sector under the Illinois

More information

SECTION PRESSURE TESTING OF PIPING

SECTION PRESSURE TESTING OF PIPING SECTION 15044 PRESSURE TESTING OF PIPING PART 1 - GENERAL 1.01 DESCRIPTION A. Scope of Work: This section specifies the leakage and pressure testing of piping. B. Testing Records: PART 2 - PRODUCTS 2.01

More information

Originally Issued: 10/08/2010 Revised: 10/30/2015 Valid Through: 10/31/2016

Originally Issued: 10/08/2010 Revised: 10/30/2015 Valid Through: 10/31/2016 EVALUATION SUBJECT: ITW ALPINE HANGERS AND ANCHORS REPORT HOLDER: ITW Building Components Group Inc. 13825 W. Business Center Dr. Unit A Lake Forest, IL 60045 (800) 521-9790 www.alpineitw.com CSI Division:

More information

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HVAC DUCTS AND CASINGS.

EVALUATION SUBJECT: DIVISION: HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION: HVAC DUCTS AND CASINGS. ICC-ES Report PMG-1171 Reissued 11/2018 This report is subject to renewal 11/2019 EVALUATION SUBJECT: UNDERGROUND SINGLE WALL & DOUBLE WALL INSULATED DUCT FOR HVAC DIRECT BURIAL APPLICATIONS AND UNDERGROUND

More information

SECTION DOMESTIC WATER PIPING

SECTION DOMESTIC WATER PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. B. Related Sections

More information

hockey hockey Integral Weighted Goals Aluminium Goals Fence Folding Goals Premier Hockey Goals Folding Wheelaway Goals

hockey hockey   Integral Weighted Goals Aluminium Goals Fence Folding Goals Premier Hockey Goals Folding Wheelaway Goals hockey www.harrod.uk.com 67 Integral Weighted Goals Aluminium Goals Fence Folding Goals Premier Folding Wheelaway Goals Freestanding Goals Socketed Goals Backboards Nets Indoor Posts hockey setting the

More information

SPECIFICATIONS - DETAILED PROVISIONS Section Butterfly Valves C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Butterfly Valves C O N T E N T S SPECIFICATIONS - DETAILED PROVISIONS Section 15103 - Butterfly Valves C O N T E N T S PART 1 - GENERAL... 1 1.01 REQUIREMENT... 1 1.02 VALVE MANUFACTURER... 1 1.03 GUARANTEE... 1 PART 2 - PRODUCT... 1

More information

Airfix D-E-B Installation and operating instructions

Airfix D-E-B Installation and operating instructions www.flamco.nt-rt.ru Airfix D-E-B Installation and operating instructions Dear Customer, With the Airfix D-E-B membrane expansion vessel you have acquired a Flamco quality product. This expansion vessel

More information

Treated w/ mildew and UV inhibitors to keep its beauty through all seasons

Treated w/ mildew and UV inhibitors to keep its beauty through all seasons Cover Features Ideal Spa Covers Have Over 20 Points Of Reinforcement Ideal Spa Cover Features Marine Grade Vinyl Treated w/ mildew and UV inhibitors to keep its beauty through all seasons Double Reinforced

More information

MSA Cairns FIRE HELMET PRODUCT SPECIFICATION

MSA Cairns FIRE HELMET PRODUCT SPECIFICATION MSA Cairns FIRE HELMET PRODUCT SPECIFICATION PRODUCT TYPE: Structural Firefighting Helmet PRODUCT MODEL(S): PURPOSE: To supply a uniform, standard product specification for a thermoplastic structural fire

More information

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 257a. September 16, 2013 September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking

More information

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013 September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally

More information

mullen shower base LIFE TIME Suitable for: ALL Floor Types Floor Coverings V Vinyl Wood Flooring Concrete Slab C Ceramic Tiles

mullen shower base LIFE TIME Suitable for: ALL Floor Types Floor Coverings V Vinyl Wood Flooring Concrete Slab C Ceramic Tiles mullen shower base Suitable for: ALL Floor Types Wood Flooring Concrete Slab Floor Coverings V Vinyl C Ceramic Tiles L WA R R A N T Y The Mullen 49 7 /8 x 30 1 /8 installed with vinyl floor covering (Altro

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment

More information

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013 October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve

More information

SECTION 48 - TRAFFIC STRIPES AND PAVEMENT MARKINGS TABLE OF CONTENTS

SECTION 48 - TRAFFIC STRIPES AND PAVEMENT MARKINGS TABLE OF CONTENTS SECTION 48 - TRAFFIC STRIPES AND PAVEMENT MARKINGS TABLE OF CONTENTS Section Page 48-1 GENERAL... 48.1 48-2 THERMOPLASTIC TRAFFIC STRIPES AND PAVEMENT MARKINGS... 48.1 48-3 PAINTED TRAFFIC STRIPES AND

More information

XSPLATFORMS ROOFTOP SYSTEMS -

XSPLATFORMS ROOFTOP SYSTEMS - XSPLATFORMS Since 1995, XSPlatforms has built a compelling track record designing, manufacturing, assembling, inspecting, and managing rooftop fall protection systems worldwide. XSPlatforms systems are

More information

Item 404 Driving Piling

Item 404 Driving Piling Item Driving Piling 1. DESCRIPTION Drive piling. 2. EQUIPMENT 2.1. Driving Equipment. Use power hammers for driving piling with specified bearing resistance. Use power hammers that comply with Table 1.

More information

Kestrel Aluminium Systems Limited. Product Manual Section 10 Thermal Framing System. Manual Version

Kestrel Aluminium Systems Limited. Product Manual Section 10 Thermal Framing System. Manual Version Kestrel luminium Systems Limited Product Manual Section 10 Manual Version 23.0.1 Kestrel luminium Systems Section 10.01 Product Specification 10.01.01 sheet 1 Product specification 10.01.01 sheet 2 Product

More information

l DESCRIPTION l FEATURES l LIMITATIONS l TYPICAL APPLICATIONS l MATERIAL SPECIFICATIONS TECHNICAL MANUAL SECTION 2.3 PAGE 1 / 6

l DESCRIPTION l FEATURES l LIMITATIONS l TYPICAL APPLICATIONS l MATERIAL SPECIFICATIONS TECHNICAL MANUAL SECTION 2.3 PAGE 1 / 6 www.ucanfast.com TECHNICAL MANUAL SECTION 2.3 PAGE 1 / 6 l DESCRIPTION The UCAN WAG anchor is a fully threaded torque controlled expansion anchor assembled with a three segment expansion clip. All parts

More information

TABLE OF CONTENTS International Racquetball Federation officially approved specifications. Copyright 01/13/1983; rev.

TABLE OF CONTENTS International Racquetball Federation officially approved specifications. Copyright 01/13/1983; rev. Racquetball Court Specifications TABLE OF CONTENTS International Racquetball Federation officially approved specifications. Copyright 01/13/1983; rev. 1988; 1997, 2013 SECTION ONE: Performance and Specifications

More information

SECTION CLIMBING WALLS. PART 1 GENERAL 1.1 SUMMARY A. This section includes the following:

SECTION CLIMBING WALLS. PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: SECTION 131200 - CLIMBING WALLS PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: 1. GFRC Rock Realistic Climbing Wall System B. Related Sections 1. Division 04 Unit Masonry 2. Division

More information

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly

More information

WEDGE-ALL Wedge Anchors

WEDGE-ALL Wedge Anchors WEDGE-ALL Wedge Anchors The Wedge-All wedge anchors are a non-bottom bearing, wedge-style expansion anchor for use in solid concrete or grout-fi lled masonry. A one-piece clip ensures uniform holding capacity

More information

Bike-Shell Model 301P

Bike-Shell Model 301P Bike-Shell Model 301P NEW design, one piece FRP Composite bike locker NO ASSEMBLY required Specify the 300 Series lockers for the highest customer satisfaction from the no-assembly ready-touse delivery

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1048 - REVISED: 2009 Double Check Detector Fire Protection Backflow Prevention Assemblies Separate, complete laboratory

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR WATER HEATER SUPPLY SHUTOFF VALVE WITH A / THERMAL EXPANSION CONTROL VALVE IGC 128-2006a8 1. PURPOSE 1.1 The purpose

More information

MICHIGAN DEPARTMENT OF TRANSPORTATION 6" X 8" (NOMINAL POST) 3-1/2" DIA. 2 HOLES TAPERED HARD WOOD WEDGES (HARDWOOD WEDGE

MICHIGAN DEPARTMENT OF TRANSPORTATION 6 X 8 (NOMINAL POST) 3-1/2 DIA. 2 HOLES TAPERED HARD WOOD WEDGES (HARDWOOD WEDGE X (NOMINAL POST) 1-1/ DIA. 2 HOLES X 8" (NOMINAL POST) 3-1/ DIA. 2 HOLES TAPERED HARD WOOD WEDGES (HARDWOOD WEDGE TO BE OAK, MAPLE OR OTHER APPROVED DENSE HARDWOODS) TO HOLD POST IN A STABLE POSITION AFTER

More information

1. Hybrid: Seamless, Textured Substrate Climbing Wall System and GFRC Rock Realistic Climbing Wall System

1. Hybrid: Seamless, Textured Substrate Climbing Wall System and GFRC Rock Realistic Climbing Wall System SECTION 131200 CLIMBING WALLS PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: 1. Hybrid: Seamless, Textured Substrate Climbing Wall System and GFRC Rock Realistic Climbing Wall System

More information

BARRIER OFFSET 0" A 6" 6" A 12" 12" A 26" A 26" 3A OR 4A L OR S * ** L OR S L OR S

BARRIER OFFSET 0 A 6 6 A 12 12 A 26 A 26 3A OR 4A L OR S * ** L OR S L OR S ACCEPTABLE (TCB) TYPES AND ANCHORING DETAILS BASED ON UNDERLYING SURFACE TYPE AND BARRIER OFFSET FROM DROP-OFF BARRIER OFFSET UNDERLYING SURFACE 0" A 6" 6" A 12" 12" A 26" A 26" TCB TYPE DETAIL TCB TYPE

More information

OPERATION AND INSTRUCTION MANUAL

OPERATION AND INSTRUCTION MANUAL OPERATION AND INSTRUCTION MANUAL Swivel Anchor Model: SWS100N-316-CTS Patent US # 8,424,638 WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT

More information

FXT. FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS

FXT. FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS FXT FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS FXT Cooling Towers should be rigged and assembled as outlined in this bulletin. These procedures should be thoroughly reviewed prior to the actual

More information

FALL PROTECTION

FALL PROTECTION 115500 FALL PROTECTION PART 1 GENERAL 1.01 General A. Cornell University seeks to prevent exposures to fall hazards whenever possible and protect personnel that may be exposed to fall hazards. Therefore,

More information

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina TEST REPORT Report No.: G4124.02-109-44 Rendered to: VELUX America LLC Greenwood, South Carolina PRODUCT TYPE: Sun Tunnel Skylight SERIES/MODEL: TCC 022 SPECIFICATION(S): Occupational Safety and Health

More information

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL)

STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL) STANDARD SPECIFICATION FOR SPLIT TEES (HOT TAP MATERIAL) TEE (HOT TAPPING MATERIAL) S-04-02-040 Page 1 of 7 1.0 SCOPE This specification covers the basic requirements for the design, manufacture and supply

More information

Submittal / Substitution Request

Submittal / Substitution Request Submittal / Substitution Request SUBMITTED TO: To: Firm: Project: Submitted Product: SIMPSON STRONG-TIE WEDGE-ALL WEDGE ANCHOR Specified Product: Section: Page: Detail/Sheet No.: Description of Application:

More information

Safe Work Practices (SWP) SWP (6) FALL PROTECTION PROGRAM

Safe Work Practices (SWP) SWP (6) FALL PROTECTION PROGRAM SWP (6) FALL PROTECTION PROGRAM The following information on Fall Protection has been based around the BC OHS Regulations, standards, policies and guidelines. Prior to starting work outside of BC, the

More information

Engineering Data Sheet

Engineering Data Sheet Page 1 of 6 CE MARKING AND THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC Valves must be installed into a well designed system and it is recommended that the system be inspected in accordance with the appropriate

More information

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE

IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC PURPOSE INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR BALL VALVES IAPMO IGC 157-20067 1 PURPOSE 1.1 The purpose of this standard is to establish an acceptable standard

More information

CLEANING, INSPECTION, AND TESTING OF SEWERS

CLEANING, INSPECTION, AND TESTING OF SEWERS CLEANING, INSPECTION, AND TESTING OF SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Cleaning, Inspecting, and Testing Sanitary Sewers B. Cleaning, Inspecting, and Testing Storm Sewers C. Cleaning and

More information