Ocean Observatories Initiative Cabled Array Observatory Extension Cables/Connectors

Size: px
Start display at page:

Download "Ocean Observatories Initiative Cabled Array Observatory Extension Cables/Connectors"

Transcription

1 Ocean Observatories Initiative Cabled Array Observatory Extension Cables/Connectors Mike Harrington

2 Infrastructure Cable Laying Problem: Get to the interesting stuff. Laying interconnection (instrument and between nodes) cables with lengths between 150m and 4+ km. (Cables up to 200m have been deployed from tool basket/undervators) Solution: Key Enabling Technology - a cable laying system (ROCLS) has been used to successfully lay 80+ km of interconnect cable on OOI/CA. Description: the ROCLS system is composed of a drum inside a frame that is hung beneath the ROV. However, difficult to monitor and control cable tension. The system is subject to ship/rov motions, so restricted in sea state.

3 Axial Caldera Layout

4 Extension Cable Deployments 18 Electrical Optical Cables > 1Km long - 64km Total 42 Electrical Extension Cables with Wet Mate Connectors < 1km Lengths to 4800m installed by ROV Lengths to 17km installed by cable ship One failure during installation Hockle

5

6 Lessons Learned Plan Plan Plan Detailed surveys/route plan 2 years in advance Lots of meetings with vendors (ROPOS/ODI) Detailed loading of the spools Run the route before the lay Visual inspection of wet mate connectors. Test Test Test

7 ROV Cable Deployment

8 One Event.. X = 0 Z = 0 Secondary Cable UHMWPE 12-strand core with braided jacket 1.9 cm" OD x 3051 m EM Cable 4x #24 AWG and 2x #18 AWG conductors, Vectran strain member, urethane jackets 1.27 cm OD x 285 m 46" Float 474k g buoyancy Secondary Leg Releases Science Pod 182 kg buoyancy Z = -200 m VM Platform 2120 kg buoyancy EOM Cable 6x #10 AWG conductors, 6x SM fibers, Kevlar strain member, HDPE jacket 2.54 cm OD x 3085 m Cable Floats 94 syntactic floats attached to EOM cable 9 kg buoyancy/each Secondary Anchor 5455 kg Air / 4745 kg SW X = m EOM Anchor 5455 kg Air / 4745 kg SW EOM Leg Releases X = 1528 m Z = m

9 One Event Installed Mooring Turned it on Overcurrent Event Doh! How to debug with limited time/hardware? Output Port? Flooded Package? Bad Connector? Left to do other work for a couple of days.

10 One Event James Tilley Could the 200 Meter extension 2 conductor cable be wired backward? Seemed very unlikely but we had spare on board. Sure enough simple fix but could have been very ugly if we went down some other diag paths.

11 Control System

12 Problem: What is the right balance for redundancy backup systems versus simple? (why to planes have 2 engines now and not 4?) It is very expensive to service the infrastructure when there is a failure in the system so the tendency is to add more redundant and backup systems but this makes the system more complex, harder to fully test, more difficult to configure correctly, harder to operate so it is not clear that the final system is always more reliable or not. Solution: Focus on simple redundant systems where possible that do not rely on overly complex control circuits and are simple to test without adding new failure points.

13 Example: Overcurrent Protection We added many different points for overcurrent detect and port shut off in the secondary nodes but the logic and characteristics for each one are different and can make it difficult to test. In the end the DC/DC converters themselves have protection circuitry that probably was good enough to prevent hardware damage. Care must be taken to fully characterize power needs of instruments in all modes- many have large inrush needs but small overall power requirements because they are typically used with batteries. may need to add inline resistors or output caps. Fully testing all features in all cases can be difficult because they all have different set points/ response times etc. May end up with latent issues that don t show up until final integration testing (or worse after deployment)

14 Example: Loopback Testing We added a loopback configuration on the instrument ports to test the port when the relays were open to the outside world. Caused an issue in the Network Switch for Ethernet Instruments when the signals were looped back. Issue did not show up until after deployments because system used slightly differently than during testing.

NT10-18 NATSUSHIMA / HYPER-DOLPHIN

NT10-18 NATSUSHIMA / HYPER-DOLPHIN NT10-18 NATSUSHIMA / HYPER-DOLPHIN Kumano-Nada October 2010 Earthquake and Tsunami Research Project for Disaster Prevention JAMSTEC TABLE OF CONTENTS 1. INTRODUCTION 2. SCHEDULE 3. DIVE RESULTS 4. CONCLUSIONS

More information

KAIYO Cruise Report. KY15-05Leg2. Construction of DONET2 system. Off Kii Channel. Kumano-nada. March.12 March.29, 2015

KAIYO Cruise Report. KY15-05Leg2. Construction of DONET2 system. Off Kii Channel. Kumano-nada. March.12 March.29, 2015 KAIYO Cruise Report KY15-05Leg2 Construction of DONET2 system Off Kii Channel Kumano-nada March.12 March.29, 2015 Japan Agency for Marine-Earth Science and Technology (JAMSTEC) Contents 1. Cruise Information...

More information

RAMSTM. 360 Riser and Anchor-Chain Integrity Monitoring for FPSOs

RAMSTM. 360 Riser and Anchor-Chain Integrity Monitoring for FPSOs RAMS 360 Riser and Anchor-Chain Integrity Monitoring for FPSOs Introduction to RAMS Tritech s RAMS is a 360 anchor-chain and riser integrity monitoring system for Floating Production Storage and Offloading

More information

NT09-21 Cruise Report SURUGA-BAY Cable Laying Experiment / VBCS Function Test

NT09-21 Cruise Report SURUGA-BAY Cable Laying Experiment / VBCS Function Test NT09-21 Cruise Report SURUGA-BAY Cable Laying Experiment / VBCS Function Test December 2009 Table of Contents 1. Overview 2. Schedule 3. Dive Summary 4. Concluding Remarks 1. Overview A unique development

More information

ALOHA CABLED OBSERVATORY. PHASE 2 Installation Cruise. Preliminary Report. Fred Duennebier, David Harris, James Jolly. November 2, Rev.

ALOHA CABLED OBSERVATORY. PHASE 2 Installation Cruise. Preliminary Report. Fred Duennebier, David Harris, James Jolly. November 2, Rev. ALOHA CABLED OBSERVATORY PHASE 2 Installation Cruise Preliminary Report Fred Duennebier, David Harris, James Jolly November 2, 2008 Rev. 2 ACO Report page 1 of 10 Summary: The purpose of cruise TGT 226,

More information

Sensor Platform Project Marine Trials Bidders Conference. Fundy Ocean Research Center for Energy fundyforce.ca

Sensor Platform Project Marine Trials Bidders Conference. Fundy Ocean Research Center for Energy fundyforce.ca Sensor Platform Project Marine Trials Bidders Conference Fundy Ocean Research Center for Energy fundyforce.ca 1 Project Team FORCE OceanWorks International Preliminary Design, Operational Procedures Murray

More information

Chapter 9: Sea operations

Chapter 9: Sea operations Chapter 9: Sea operations ANTARES takes advice from IFREMER for the sea operations, which concern the installation and recovery of the different components of the detector : Junction Box, Strings, Interconnecting

More information

Ocean Observatories Initiative (OOI) Moorings: New Capabilities for Seagoing Science

Ocean Observatories Initiative (OOI) Moorings: New Capabilities for Seagoing Science Ocean Observatories Initiative Ocean Observatories Initiative (OOI) Moorings: New Capabilities for Seagoing Science presented by Ed Dever and Walt Waldorf November 20, 2014 OOI Science Themes Coastal and

More information

Product Overview. Product Description CHAPTER

Product Overview. Product Description CHAPTER CHAPTER 1 This chapter provides a functional overview of the Cisco Redundant Power System 2300 and covers these topics: Product Description, page 1-1 Features, page 1-3 Supported Devices, page 1-4 Deployment

More information

Successful completion of the course leads to the award of the Technical Training Solutions Certificate of Competence 510: Instrumentation.

Successful completion of the course leads to the award of the Technical Training Solutions Certificate of Competence 510: Instrumentation. INSTRUMENTATION COURSE 510: 3 DAYS: Max 8 Candidates This course covers the key aspects of industrial instrumentation and is designed to enable maintenance personnel to carry out commissioning, calibration

More information

Summary of Architecture Parallel Session. G. Hallewell/CPP Marseille P. Piattelli/ LNS Catania

Summary of Architecture Parallel Session. G. Hallewell/CPP Marseille P. Piattelli/ LNS Catania Summary of Architecture Parallel Session G. Hallewell/CPP Marseille P. Piattelli/ LNS Catania Parallel Session A1.2: Architecture: First session mainly devoted to undersea connectivity Chair: G. HALLEWELL,

More information

ANTARES MECHANICS: A CRITICAL ANALYSIS IN VIEW OF A LARGE SCALE DETECTOR

ANTARES MECHANICS: A CRITICAL ANALYSIS IN VIEW OF A LARGE SCALE DETECTOR ANTARES MECHANICS: A CRITICAL ANALYSIS IN VIEW OF A LARGE SCALE DETECTOR (thanks to M. Anghinolfi, M. Jaquet, P. Lagier, P. Lamare, M. Musumeci, P. Vernin) NIKHEF - 07/10/03 Stefano CUNEO - INFN-GE 1/11

More information

RPS900W Redundant Power Supply. Installation Guide.

RPS900W Redundant Power Supply. Installation Guide. RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A

More information

ROPES. Material Nylon. Construction 8 12 strand, plaited Measure Metric U.S.

ROPES. Material Nylon. Construction 8 12 strand, plaited Measure Metric U.S. Catenary curve moorings are rigged from a combination of sinking and buoyant ropes. The properties of each rope perform specific functions or impart specific features to the mooring. As more than 90 per

More information

The below identified patent application is available for licensing. Requests for information should be addressed to:

The below identified patent application is available for licensing. Requests for information should be addressed to: DEPARTMENT OF THE NAVY NAVAL UNDERSEA WARFARE CENTER DIVISION NEWPORT OFFICE OF COUNSEL PHONE: (401) 832-3653 FAX: (401) 832-4432 NEWPORT DSN: 432-3653 Attorney Docket No. 96811 Date: 14 May 2008 The below

More information

Safe hydraulics for hydroforming presses. more finished product to be created from less raw material.

Safe hydraulics for hydroforming presses. more finished product to be created from less raw material. profile Drive & Control Safe hydraulics for hydroforming presses Safety Standard Guidelines for Hydraulic Presses In several western regions, safety standards exist that describe how to achieve safe control

More information

Location: Barkley Canyon Date: September 9, 2013 Constraints: none

Location: Barkley Canyon Date: September 9, 2013 Constraints: none Page 1 of 11 DIVE PLAN R1650 Location: Barkley Canyon Date: September 9, 2013 Constraints: none Objectives Deploy POD 1 autonomous CTD Survey POD 3 for sediment enrichment sites; deposit cages; collect

More information

NSF's Ocean Observatories Initiative: Building Research Infrastructure for the Pacific Northwest and the Broader Community

NSF's Ocean Observatories Initiative: Building Research Infrastructure for the Pacific Northwest and the Broader Community Agenda Item B.3.b Supplemental OOI PowerPoint April 2013 Ocean Observatories Initiative NSF's Ocean Observatories Initiative: Building Research Infrastructure for the Pacific Northwest and the Broader

More information

A NEW APPROACH TO BUCKLING DETECTION IN OFFSHORE PIPELINE LAYING

A NEW APPROACH TO BUCKLING DETECTION IN OFFSHORE PIPELINE LAYING A NEW APPROACH TO BUCKLING DETECTION IN OFFSHORE PIPELINE LAYING By Marian Copilet, Durham Pipeline Technology Ltd., Gateshead, UK & Prof. Ernie Appleton, University of Durham 1. ABSTRACT This paper discusses

More information

CONTROL and INSTRUMENTATION

CONTROL and INSTRUMENTATION CONTROL and INSTRUMENTATION COURSE 500: 5 DAYS: Max 8 Candidates This course covers the key aspects of current instrumentation and process control technology and is designed to enable maintenance personnel

More information

DIVE PLAN Leg 1 Dive 11 Recover Wally 1

DIVE PLAN Leg 1 Dive 11 Recover Wally 1 DIVE PLAN Leg 1 Dive 11 Recover Wally 1 Page 1 of 6 Location: Barkley Canyon Date: 9 May, 2014 14:00 Constraints: Weather, Sufficient deck space ROV Dive # OE 114 Objectives Prepare Wally I cable for recovery

More information

APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL

APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL ROV & AUV PRODUCTS GRE (Glass Reinforced Epoxy) CS-MS 55 & 66 SERIES MINI-CON HUMMER GLOBE-CON ALL-WET

More information

Technical Literature. Plasma. Rope Quick Q & A

Technical Literature. Plasma. Rope Quick Q & A Technical Literature Plasma Rope Quick Q & A Plasma Rope Properties & Performance Plasma Rope "Quick" Q & A This brief guide is designed as a quick reference guide to basic questions on Cortland s Plasma

More information

Pioneer Array Micro-siting Public Input Process Frequently Asked Questions

Pioneer Array Micro-siting Public Input Process Frequently Asked Questions Pioneer Array Micro-siting Public Input Process Frequently Asked Questions The National Science Foundation (NSF) has completed the micro-siting of the moored array of the Ocean Observatories Initiative

More information

Noise Experiment #2. Marine Physical Laboratory Scripps Institution of Oceanography La Jolla, CA February 22 February 2010

Noise Experiment #2. Marine Physical Laboratory Scripps Institution of Oceanography La Jolla, CA February 22 February 2010 Noise Experiment #2 Marine Physical Laboratory Scripps Institution of Oceanography La Jolla, CA 92093-0701 16 February 22 February 2010 1. Objective The objective of the noise experiment is to observe

More information

Alvin Debrief Summary Seven Cruises for 91 dives. Southern California Juan de Fuca Costa Rica Guaymas Basin Galapagos

Alvin Debrief Summary Seven Cruises for 91 dives. Southern California Juan de Fuca Costa Rica Guaymas Basin Galapagos Seven Cruises for 91 dives Southern California Juan de Fuca Costa Rica Guaymas Basin Galapagos Overview All the PIs were very satisfied with their Alvin experience and felt that their scientific goals

More information

IBU3 Manual Addendum 1

IBU3 Manual Addendum 1 This addendum covers the follow items. Connection of airsoft micro switch Connection of Taigen airsoft recoil units Selecting airsoft mode Settings for clutch style gearboxes Motor enable selection Confirmation

More information

National Report of China

National Report of China National Report of China Yu Ting (NMDIS), State Oceanic Administration (SOA), China DBCP 29, 27 Sep. 2013, Paris, France Contents 1 Current program status 2 Future deployment plan 3 Technical development

More information

Sewable LED kits Teaching Notes Issue 1.1

Sewable LED kits Teaching Notes Issue 1.1 Teaching Notes Issue 1.1 Product information: www.kitronik.co.uk/quicklinks/2702/ TEACHER Sewable LED kits Introduction About the project kit This project kit has been carefully designed for use by textiles

More information

ROV Development ROV Function. ROV Crew Navigation IRATECH SUB SYSTEMS 2010

ROV Development ROV Function. ROV Crew Navigation IRATECH SUB SYSTEMS 2010 IR AT EC H SU B SY ST EM S 20 10 Remotely Operated Vehicle ROV INTRODUCTORY 2008 2008 1 KEY POINTS ROV Introductory ROV Development ROV Function Types of ROV ROV Crew Navigation ROV Components 2 ROV Development

More information

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President

Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President Lowell Instruments Application Note #TCMA Deploying the TCM-1 Tilt Current Meter in an Inverted (Hanging) Orientation By: Nick Lowell, Founder & President 1 Introduction The TCM-1 Tilt Current Meter (TCM)

More information

TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box

TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box TANKTRONIC STANDARD CONFIGURATION Single Tank control unit Twin Tank (common valve) control unit Twin Tank (separate valves) control unit ADVANCED CONFIGURATION Multiple Tanks control unit S-Module Tanktronic

More information

KY10-15 KAIYO / HYPER-DOLPHIN

KY10-15 KAIYO / HYPER-DOLPHIN KY10-15 KAIYO / HYPER-DOLPHIN Kumano-Nada January 2011 Earthquake and Tsunami Research Project for Disaster Prevention JAMSTEC TABLE OF CONTENTS 1. INTRODUCTION 2. SCHEDULE 3. DIVE RESULTS 4. CONCLUSIONS

More information

The Next Generation Easy-to-Deploy (ETD) Tsunami Assessment Buoy

The Next Generation Easy-to-Deploy (ETD) Tsunami Assessment Buoy The Next Generation Easy-to-Deploy (ETD) Tsunami Assessment Buoy R.A. Lawson and D. Graham Science Applications International Corporation 4025 Hancock Street San Diego, CA 92110 USA S. Stalin, C. Meinig,

More information

Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB

Optical Time Domain Reflectometer. Operating System 2 Windows XPe Windows XP Pro with desktop option 256 MB CMA 4500 Series Optical Time Domain Reflectometer The CMA 4500 continues NetTest s tradition as the industry s premier OTDR solution designed with the high performance and scalability necessary to meet

More information

GAS FUEL VALVE FORM AGV5 OM 8-03

GAS FUEL VALVE FORM AGV5 OM 8-03 ALTRONIC AGV5 OPERATING MANUAL GAS FUEL VALVE FORM AGV5 OM 8-03 WARNING: DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE PERSONAL INJURY TO OPERATORS

More information

Session Objectives. At the end of the session, the participants should: Understand advantages of BFD implementation on S9700

Session Objectives. At the end of the session, the participants should: Understand advantages of BFD implementation on S9700 BFD Features Session Objectives At the end of the session, the participants should: Understand advantages of BFD implementation on S9700 Understand when to use BFD on S9700 1 Contents BFD introduction

More information

Seaeye Falcon powerful portable versatile

Seaeye Falcon powerful portable versatile Seaeye Falcon 12170 powerful portable versatile The powerful, portable and versatile Seaeye Falcon designed for coastal and inshore operations to 300 metres water depth or for fly away operations offshore.

More information

TSC developed the practical use of magnetostrictive method for strain measurement and it is embodied in the StressProbe instrument.

TSC developed the practical use of magnetostrictive method for strain measurement and it is embodied in the StressProbe instrument. TSC StressProbe StressProbe Background OVERVIEW OF TECHNIQUE Magnetisation of ferromagnetic materials such as iron and mild steel have an interaction with elastic strain called magnetostriction, that is,

More information

Electrical. OSHA Office of Training and Education 1

Electrical. OSHA Office of Training and Education 1 Electrical OSHA Office of Training and Education 1 Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due

More information

QUICK START GUIDE TO DRINKING WATER MONITORING

QUICK START GUIDE TO DRINKING WATER MONITORING APPENDIX F QUICK START GUIDE TO DRINKING WATER MONITORING Introduction: This Quick Start guide is designed to allow users who are already familiar with the basic use of YSI 6-series sondes for surface

More information

For ELECTRIC ANCHOR WINCH Models: T Pontoon 35 T sw Salt Water Series Coastal 35

For ELECTRIC ANCHOR WINCH Models: T Pontoon 35 T sw Salt Water Series Coastal 35 INSTALLATION AND OPERATING INSTRUCTIONS ANCHOR WINCHES For ELECTRIC ANCHOR WINCH Models: T10109-35 Pontoon 35 T10102-35sw Salt Water Series Coastal 35 If you have any questions or difficulty installing

More information

INSTALLATION AND OPERATING INSTRUCTIONS. T10219-AD Deckboat 40 with AutoDeploy and Wireless Remote Control

INSTALLATION AND OPERATING INSTRUCTIONS. T10219-AD Deckboat 40 with AutoDeploy and Wireless Remote Control INSTALLATION AND OPERATING INSTRUCTIONS ANCHOR WINCH T10219-AD Deckboat 40 with AutoDeploy and Wireless Remote Control If you have any questions or difficulty installing this product, we are here to help!

More information

RVSS Appendix A Overview

RVSS Appendix A Overview RVSS Appendix A Overview Presented at RVTEC 2008 by Rich Findley rfindley@rsmas.miami.edu Definitions WINCH OWNER: The party or their representative who is normally responsible for the operation, inspection,

More information

LVU2800 Series. Ultrasonic Level Transmitter

LVU2800 Series. Ultrasonic Level Transmitter LVU2800 Series Ultrasonic Level Transmitter 2 of 23 INTRODUCTION / TABLE OF CONTENTS Step One The LVU2800 Series is a general purpose ultrasonic level transmitter that provides a loop powered 4 20 ma output.

More information

Life Cycle Testing of 3x19 Wire Rope

Life Cycle Testing of 3x19 Wire Rope Life Cycle Testing of 3x19 Wire Rope Shipboard Scientific Support Equipment: Oceanographic Cable NSF Grant No. 0555000 Presented by Rick Trask (WHOI) Topics Results of Bending Fatigue Tests conducted on

More information

TECHNICAL SPECIFICATION SCHILLING UHD III WORK CLASS ROV SYSTEM

TECHNICAL SPECIFICATION SCHILLING UHD III WORK CLASS ROV SYSTEM TECHNICAL SPECIFICATION SCHILLING UHD III WORK CLASS ROV ROVOP, Silvertrees Drive, Westhill, Aberdeen AB32 6BH, Scotland, UK T +44 (0) 1224 472565 E rov@rovop.com www.rovop.com TECHNICAL SPECIFICATION

More information

Array Solutions 350 Gloria Rd Sunnyvale, TX Phone FAX

Array Solutions 350 Gloria Rd Sunnyvale, TX Phone FAX Array Solutions 350 Gloria Rd Sunnyvale, TX 75182 Phone 972-203 2008 FAX 972-203 8811 E-mail: info@arraysolutions.com Installation Instructions AS-AYL-4 WM Array Solutions K9AY Loop Wire/Mast Kit Thank

More information

SENSAPHONE APPLICATION NOTE. Functions: C Programming, Pump Control, Data Logging

SENSAPHONE APPLICATION NOTE. Functions: C Programming, Pump Control, Data Logging SENSAPHONE APPLICATION NOTE Application: Pump Station Volumetric Flow Calculation Functions: C Programming, Pump Control, Data Logging Sensaphone Model: SCADA 3000 Who needs to perform Volumetric Flow

More information

Stand-Alone Bubble Detection System

Stand-Alone Bubble Detection System Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When

More information

PURA. Pure Gas Dewpoint Transmitter. Users Guide

PURA. Pure Gas Dewpoint Transmitter. Users Guide PURA Pure Gas Dewpoint Transmitter Users Guide Issue January 2003 Page 2 Table of Contents SECTION PAGE 1 Product Overview 3 2 Preparation 3 3 Installation 3 3.1 PURA Premium & OEM Dewpoint Transmitter

More information

Baseline Two-Wire Technology

Baseline Two-Wire Technology Baseline Two-Wire Technology Baseline s bicoders work with Baseline s biline two-wire technology to create the only true bi-direc onal two-wire devices in the industry. Baseline s bicoders not only receive

More information

Operating Manual for the Evance Iskra R9000 Wind Turbine

Operating Manual for the Evance Iskra R9000 Wind Turbine L3 CS-01 Operating Manual Operating Manual for the Evance Iskra R9000 Wind Turbine //Level 3 Procedures/L3-CS-01 Operating Manual Date of Issue : 8 th December 2009 Page 1 of 13 Description Author Checked

More information

Power Supply Facilities Failure (Units 3-4 Temporary M/C (A), etc.) March 22, 2013 Tokyo Electric Power Company

Power Supply Facilities Failure (Units 3-4 Temporary M/C (A), etc.) March 22, 2013 Tokyo Electric Power Company < Reference > Power Supply Facilities Failure (Units 3-4 Temporary M/C (A), etc.) March 22, 2013 Tokyo Electric Power Company Occurrence of Events in a Chronological Order At around 6:57 PM on March 18,

More information

The TRV series has sufficient thrust to allow operations in currents up to 3 knots and down to depths of 3,300. Wolfgang Burnside

The TRV series has sufficient thrust to allow operations in currents up to 3 knots and down to depths of 3,300. Wolfgang Burnside The TRV series has sufficient thrust to allow operations in currents up to 3 knots and down to depths of 3,300 Wolfgang Burnside TRV-005 Series: Standard Features and Benefits Frame The TRV 005 Series

More information

ISE Subsea Tools and Toolsleds

ISE Subsea Tools and Toolsleds 1734 Broadway St. Port Coquitlam, B.C. V3C 2M8, Canada +1.604.942.5223 +1.604.942.7577 info@ise.bc.ca www.ise.bc.ca ISE Subsea Tools and Toolsleds 1 INTRODUCTION The value of an ROV is increased by its

More information

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version User Manual Heads-Up Display (HUD) Mechanical Button Version DiveCAN Table of Contents 1. Introduction...4 1.1 Features...4 2. Physical Description...5 3. Reading the PPO2...6 3.1 Modified Smither s Code...7

More information

Electrical Shore Connections

Electrical Shore Connections RULES FOR CLASSIFICATION OF Ships / High Speed, Light Craft and Naval Surface Craft PART 6 CHAPTER 29 NEWBUILDINGS SPECIAL EQUIPMENT AND SYSTEMS ADDITIONAL CLASS Electrical Shore Connections JULY 2014

More information

Aasta Hansteen. Operational Experiences. FFU Seminar 28 th January Tom-Erik Henriksen

Aasta Hansteen. Operational Experiences. FFU Seminar 28 th January Tom-Erik Henriksen Aasta Hansteen Operational Experiences FFU Seminar 28 th January 2016 Tom-Erik Henriksen Agenda Introduction to Aasta Hansteen Main Challenges & Risks Operational Experiences - 2015 Campaigns 2 seabed-to-surface

More information

frequently asked questions

frequently asked questions Hydra Pilot Fault Codes What do the fault codes for the Hydra Pilot mean? Fault Cause FAULT 100 FAULT 101 FAULT 102 FAULT 103 FAULT 104 FAULT 105 FAULT 106 FAULT 108 FAULT 109 FAULT 110 FAULT 111 FAULT

More information

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE 1 These instructions generally describe the installation, operation, and maintenance of subject equipment. The manufacturer reserves the right

More information

QUICK START GUIDE CB-450 DATA BUOY PLATFORM

QUICK START GUIDE CB-450 DATA BUOY PLATFORM What s Included (1) Buoy hull with data well, 450 lb buoyancy (1) Buoy tower (3) 10W Solar panels (1) Data well lid (isic-cb or pass-through) (3) Top-side lifting eyes (3) Bottom-side mooring eyes (1)

More information

BENNEX Advanced Cable Termination ACT Subsea Electrical Termination

BENNEX Advanced Cable Termination ACT Subsea Electrical Termination Doc ID 101008 rev 1 BENNEX Advanced Cable Termination ACT Subsea Electrical Termination Key Business Areas Seismic ROV Distribution & Monitoring Umbilical Terminations Process Monitoring Valves Design

More information

Job Safety Analysis. Macau PuiChing Middle School Ranger - Delphinus MATE ROV 2016

Job Safety Analysis. Macau PuiChing Middle School Ranger - Delphinus MATE ROV 2016 Job Safety Analysis Ranger - Delphinus MATE ROV 2016 Job safety analysis and control measures Prevention is better than cure, so prior to starting any task, evaluate the potential hazards and take the

More information

Water Samplers, Water Sampling with Internal Recording, Cabling, and Deployment

Water Samplers, Water Sampling with Internal Recording, Cabling, and Deployment Water Samplers, Water Sampling with Internal Recording, Cabling, and Deployment Water Samplers Care and feeding SeatermAF User interface for internally recording instruments firing water samplers with

More information

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING

ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING ACCURATE PRESSURE MEASUREMENT FOR STEAM TURBINE PERFORMANCE TESTING Blair Chalpin Charles A. Matthews Mechanical Design Engineer Product Support Manager Scanivalve Corp Scanivalve Corp Liberty Lake, WA

More information

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum

Chapter 2 Rigging. Cutting Wire Rope. Anchoring Wire Rope to Drum. Winding Wire Rope Onto Drum Chapter 2 Rigging Cutting Wire Rope The wire rope must be tightly seized on both sides of the point where the wire rope will be cut, as shown in Figure 2-1. Seize the wire rope with either seizing wire

More information

Isis Deployment. TMS and Live Boating. Inmartech08. Dave Turner Operations Co-ordinator.

Isis Deployment. TMS and Live Boating. Inmartech08. Dave Turner Operations Co-ordinator. Isis Deployment TMS and Live Boating Inmartech08 Dave Turner Operations Co-ordinator TMS Operations Why Why do do we we have have aa TMS? TMS? ItIt was was deemed deemed an an essential essential part

More information

ADDENDUM. Page iii, replace Foreword with: FOREWORD

ADDENDUM. Page iii, replace Foreword with: FOREWORD Date of Issue: May 2007 Affected Publication: API Recommended Practice 2SM, Recommended Practice for Design, Manufacture, Installation, and Maintenance of Synthetic Fiber Ropes for Offshore Mooring, First

More information

Geo-Vibro Corer

Geo-Vibro Corer High Frequency Vibro Coring System Operational Features Proven performance & high quality cores 30 kn impulse at 30 Hz for fast penetration Reliable, lightweight & cost effective Modular construction (cores

More information

GUIDELINES FOR USE GUARD

GUIDELINES FOR USE GUARD GUIDELINES FOR USE GUARD G Guard Range of Load Arrestors Retractable Fall Arrest Safety Line for Protection of Machinery & Sensitive Loads GLOBESTOCK MILE OAK INDUST. ESTATE, MAESBURY ROAD, OSWESTRY, SHROPSHIRE

More information

GV Standard X-Vent. Setup, Commissioning & Installation Guide

GV Standard X-Vent. Setup, Commissioning & Installation Guide GV Standard X-Vent Setup, Commissioning & Installation Guide Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings.

More information

DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG

DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG DIVATOR THE COMPLETE DIVING SYSTEM INTERSPIRO PRODUCT CATALOG 2009 Interspiro AB, Sweden. This publication contains or refers to proprietary information which is protected by copyright. All rights are

More information

Mooring Modifications for the Reduction of Losses to Vandalism

Mooring Modifications for the Reduction of Losses to Vandalism Mooring Modifications for the Reduction of Losses to Vandalism H. Paul Freitag Chris Meinig Andrew J. Shepherd Pacific Marine Environmental Laboratory Seattle, Washington, USA Linda D. Stratton JISAO/University

More information

QUICK START GUIDE CB-950 DATA BUOY PLATFORM

QUICK START GUIDE CB-950 DATA BUOY PLATFORM What s Included (1) Buoy hull with data well, 950 lb buoyancy (1) Buoy tower (3) 40W Solar panels (1) Data well lid (isic-cb or pass-through) (3) Top-side lifting eyes (3) Bottom-side mooring eyes (1)

More information

RR10106 Cruise Plan ITOP Mooring Recovery and PhilSea10 Seaglider Operation (R/V Revelle November 6-26, 2010)

RR10106 Cruise Plan ITOP Mooring Recovery and PhilSea10 Seaglider Operation (R/V Revelle November 6-26, 2010) RR10106 Cruise Plan ITOP Mooring Recovery and PhilSea10 Seaglider Operation (R/V Revelle November 6-26, 2010) Chief Scientist: Ren-Chieh Lien, Applied Physics Lab, University of Washington Co-Chief Scientist:

More information

Warning CABLE REPLACEMENT INSTRUCTIONS. Questions? - Call Telpro Inc. Customer Service at or

Warning CABLE REPLACEMENT INSTRUCTIONS. Questions? - Call Telpro Inc. Customer Service at or CABLE REPLACEMENT INSTRUCTIONS Warning Read and follow these warnings and the instructions that follow. Failure to do so could result in serious property damage and/or serious bodily injury. BEFORE operating

More information

GUIDELINES FOR USE -GUARD

GUIDELINES FOR USE -GUARD GUIDELINES FOR USE -GUARD G-Guard Range of Load Arresters Retractable able Fall Arrest Safety Line for Protection on of Machinery & Sensitive Loads Directive 2006/42/EC GLOBESTOCK Ltd MILE OAK INDUST.

More information

Procedure Troubleshooting the Interconnect Cables

Procedure Troubleshooting the Interconnect Cables Procedure 6.1 - Troubleshooting the Interconnect Cables Troubleshooting the upper interconnect cable 1. Remove the display housing per Procedure 7.13. Disconnect the upper interconnect cable from the upper

More information

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection SG33KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG33KTL-M. In no case shall this guide substitute for the user manual or related notes on

More information

GigaBIX Multi System 케이블콘 ( 주 ) 기술지원팀 :: 콘넥터문의 케이블문의 Termination Kits and Basic Components

GigaBIX Multi System 케이블콘 ( 주 ) 기술지원팀 :: 콘넥터문의 케이블문의 Termination Kits and Basic Components C O M M E R C I A L N E T W O R K I N G C O P P E R 15.9 Termination Kits and Basic Components AX101985 GigaBIX Rack Mount Termination Kit, 48-port GigaBIX Termination Kits The GigaBIX Termination Kits

More information

For ANCHOR WINCH Model: T Big Water 45 T sw Salt Water Series Big Water 45

For ANCHOR WINCH Model: T Big Water 45 T sw Salt Water Series Big Water 45 INSTALLATION AND OPERATING INSTRUCTIONS ANCHOR WINCHES For ANCHOR WINCH Model: T10110-45 Big Water 45 T10103-45sw Salt Water Series Big Water 45 If you have any questions or difficulty installing this

More information

SOUTH TOTO ACOUSTIC MEASUREMENT FACILITY (STAFAC) IN-WATER SYSTEMS DESIGN

SOUTH TOTO ACOUSTIC MEASUREMENT FACILITY (STAFAC) IN-WATER SYSTEMS DESIGN SOUTH TOTO ACOUSTIC MEASUREMENT FACILITY (STAFAC) IN-WATER SYSTEMS DESIGN Phil DeNolfo Mike Harrison Naval Undersea Warfare Center Division Sound & Sea Technology Newport, RI Ventura, CA Hugh Thomson Naval

More information

The TURTLE Concept Contents:

The TURTLE Concept Contents: The TURTLE Concept Contents: General Assumptions The Turtle In Brief Why Developing the Turtle Turtle Lay Outs A Field Presentation The Delta TURTLE Concept General assumptions It must be possible to develop

More information

INSTALLATION PROCEDURE FOR OPGW FIBER OPTIC CABLES

INSTALLATION PROCEDURE FOR OPGW FIBER OPTIC CABLES Page 1 of 15 INSTALLATION PROCEDURE FOR OPGW FIBER OPTIC CABLES Page 2 of 15 1. PURPOSE 2. SCOPE 3. REFERENCES 4. GENERAL INDEX 5. PROCEDURES 5.1 Line survey 5.2 Transport, loading, unloading and storage

More information

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT

MODEL ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT MODEL 862-000-200 ANALOG ALTIMETER USER'S MANUAL 330KHZ, 1000M DEPTH RATED 0.2 TO 100FT OPERATING RANGE ANALOG OUTPUT DOCUMENT NO. 430-007H September 20, 2005 S/N IMAGENEX TECHNOLOGY CORP. 209-1875 BROADWAY

More information

AFT OVERBOARD HANDLING SYSTEM: STORAGE WINCHES R/V SIKULIAQ Maximum Capability Document

AFT OVERBOARD HANDLING SYSTEM: STORAGE WINCHES R/V SIKULIAQ Maximum Capability Document AFT OVERBOARD HANDLING SYSTEM: STORAGE WINCHES R/V SIKULIAQ Maximum Capability Document Manufactured By: Rapp Hydema Model: RW-2326BS Reference Drawing Number: RH314163 Prepared By: The Glosten Associates

More information

The topics I will briefly cover, are; Stack Configurations Wellhead Connector Considerations Control Systems Tensioning Systems will be discussed by

The topics I will briefly cover, are; Stack Configurations Wellhead Connector Considerations Control Systems Tensioning Systems will be discussed by Thank you Greg. 1 The topics I will briefly cover, are; Stack Configurations Wellhead Connector Considerations Control Systems Tensioning Systems will be discussed by Mr. Muhammad Sadiq, however in short,

More information

Custom Cables and Ropes. Oceanographic and Research Solutions

Custom Cables and Ropes. Oceanographic and Research Solutions Custom Cables and Ropes Oceanographic and Research Solutions Deep Ocean Research 2 cortlandcompany.com Custom solutions that meet the challenges posed by harsh environments, hydrostatic pressures, and

More information

DP Station Keeping Event Bulletin

DP Station Keeping Event Bulletin DP Station Keeping Event Bulletin IMCA DP Station Keeping Event Bulletin 04/17 October 2017 The following event trees have been compiled from recent reports received by IMCA. The originators granted IMCA

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual Content Page For your Safety 3 General Description 3 Detection Principle 4 Operational Notes 4 Design 4 Mounting Position of CS21 5 Mounting 6 Installation of Electrical

More information

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual

SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel. DTLS Manual SCIENTIFIC DATA SYSTEMS, INC. Depth Tension Line Speed Panel DTLS Manual This document contains proprietary information. Copyright 2015 Scientific Data Systems, Inc. All rights reserved. 1 Depth Tension

More information

AFT OVERBOARD HANDLING SYSTEM R/V SIKULIAQ Top Level Maximum Capability Document

AFT OVERBOARD HANDLING SYSTEM R/V SIKULIAQ Top Level Maximum Capability Document AFT OVERBOARD HANDLING SYSTEM R/V SIKULIAQ Top Level Maximum Capability Document Manufactured By: XXX Reference Drawing Number: XXX-XXX Prepared By: [Company Name] [Engineer s Name/Stamp] [Date] Page 1

More information

Timm Signal Safety. Very durable indeed.

Timm Signal Safety. Very durable indeed. Timm Signal Safety Very durable indeed. TIMM Signal Safety is our high quality mixed polyolefin rope with a combination of high strength, great handling and superb buoyancy. It has a clear advantage over

More information

Standard League Robot Soccer EV3 Compass Training Curriculum Brian Thomas

Standard League Robot Soccer EV3 Compass Training Curriculum Brian Thomas Standard League Robot Soccer EV3 Compass Training Curriculum Brian Thomas RoboCup Junior Australia Inc Copyright 2018 1 Standard League Robot Soccer EV3 Compass Training Welcome! The aim of this curriculum

More information

HST-3000 VDSL QUICK CARD

HST-3000 VDSL QUICK CARD HST-3000 VDSL QUICK CARD ( ) March 2012 Technical Assistance: 1-866-228-3762 TAC@jdsu.com Resistive Fault Location (RFL) Test Purpose The purpose of this test is to identify and locate resistive fault

More information

Ch.5 Reliability System Modeling.

Ch.5 Reliability System Modeling. Certified Reliability Engineer. Ch.5 Reliability System Modeling. Industrial Engineering & Management System Research Center. - 1 - Reliability Data. [CRE Primer Ⅵ 2-6] Sources of Reliability Data. Successful

More information

Polatrak ROV II - Tip Contact Probe Operation Manual

Polatrak ROV II - Tip Contact Probe Operation Manual This PDF document contains Live Web Links Click them for more information from the web Polatrak ROV II - Tip Contact Probe Operation Manual A Cathodic Protection Probe with dual Ag/AgCl reference cells

More information

PRODUCT MANUAL. Diver-MOD

PRODUCT MANUAL. Diver-MOD PRODUCT MANUAL Diver-MOD Contents 1 Introduction... 1 1.1 Scope and Purpose... 1 1.2 Features... 1 1.3 System Overview... 1 1.4 Specifications... 2 2 Getting Started... 2 2.1 Supported Equipment... 2 2.2

More information

Go further, go deeper

Go further, go deeper Go further, go deeper Small footprint 13X16 m Deck layout reduced on minimum 46-9 1/2 From 6 to 12 divers Easily modifiable 1 to 3 chambers can be set up 43-11 Less expensive than a DSV Mobilized in 4

More information