New developed Insulator Selection Tool (IST) software: results of application using known Russian service experience

Size: px
Start display at page:

Download "New developed Insulator Selection Tool (IST) software: results of application using known Russian service experience"

Transcription

1 Proceedings of the 12th Asian Conference on Electrical Discharge, Graduate School of Shenzhen, Tsinghua University Shenzhen, China, November 19-22, 2004, p.p New developed Insulator Selection Tool (IST) software: results of application using known Russian service experience Igor Gutman 1* Kjell Halsan 2 Dan Hübinette 3 Evgenij Solomonik and Lev Vladimirsky 4 1 STRI AB, Box 707, 77180, Ludvika, Sweden 2 Statnett, Box 5182, Oslo, Norway 3 Svenska Kraftnät, Box 526, Vällingby, Sweden 4 HVDC Transmission Research Institute, St. Petersburg, , Russia igor.gutman@stri.se Abstract: Insulator Selection Tool (IST) and Line Performance Estimator (LPE) programs have been recently developed at STRI. Norwegian power utility Statnett has already used the LPE program for the practical evaluation of insulation alternatives to upgrade 300 kv transmission lines to 400 kv. In this particular case different future insulation options were compared based on pollution/ice performance data obtained in the laboratory. To increase level of confidence of the statistical dimensioning provided by the programs, it was decided to use the IST program (which is a part of the LPE program) to calculate the reliability of the overhead lines with known service experience. Russian pollution flashover performance data obtained in the laboratory was used as an input in the IST program to calibrate Russian guide for insulator selection. This Guide prescribes the number of cap-and-pin insulators for different pollution levels and is based on the long-time service experience. The results of the statistical dimensioning using IST program show very good agreement with demands of the Russian guide for insulator selection. Generally, without any additional corrections, the deviation is less than 10%. INTRODUCTION Insulator Selection Tool (IST) and Line Performance Estimator (LPE) programs have been developed at STRI with the support of Norwegian power utility Statnett and Swedish power utility Svenska Kraftnät. Statnett has already used the LPE program for the evaluation of insulation alternatives to upgrade 300 kv transmission lines to 400 kv [1]. In this case different future insulation options were compared based on pollution/ice performance data obtained in the laboratory. To increase level of confidence of the statistical dimensioning provided by the programs, it was decided to use the IST program (which is a part of the LPE program) to calculate the reliability of the overhead lines with known service experience. It was then suggested to use Russian pollution flashover performance data obtained in the laboratory as an input in the IST program to calibrate Russian guide for insulator selection [2]. This Guide prescribes the number of cap-and-pin insulators for different pollution levels and is based on the long-time service experience. The general statistical level of reliability behind the Guide is known as 1 outage/100 km/year. The required number of insulators in the string is calculated using IST program for the required reliability and compared with the demands of the Guide [2]. STATISTICAL DIMENSIONING OF INSULATORS WITH RESPECT TO POLLUTED CONDITIONS The IST program uses the so-called probabilistic approach for the insulation selection in respect to pollution conditions [3]-[5], where the main parameters are considered as statistical variables, defined by average values and dispersions. This is different to the commonly used deterministic approach, where the parameters are assumed to be constant. The statistical dimensioning of insulators entails the selection of the dielectric strength of an insulator, with respect to the voltage and environmental stresses, to fulfill a specific performance requirement [5]. This selection is performed by evaluating the risk of flashover of the candidate insulation options and selecting those with an acceptable performance. With reference to Figure 1, the risk for flashover can be calculated as follows [5]: Figure 1 Illustration of the input data needed for the calculation of the risk for flashover with respect to pollution conditions. It is assumed that the insulators are energized at a voltage with constant amplitude, corresponding to the maximum continuous operating voltage.

2 The variation of the pollution environmental stress (Equivalent Salt Deposit Density ESDD in our case) at the site of interest is represented by the probability density function f (ESDD). This data is normally provided by in-service measurements. A cumulative distribution function P (ESDD) describes the strength of the insulation, which is, the probability for flashover as a function of the same measure of pollution environmental stress ESDD. This data is normally provided by laboratory pollution flashover tests. The multiplication of the f (ESDD) and P (ESDD) functions gives the probability density for flashover of the insulator at the given site, and the area under this curve expresses the risk for flashover. AVAILABILITY CALCULATIONS Geometrical parameters The geometrical parameters of Russian glass cap-and-pin insulators used for the calculations are shown in Table 1 and some typical profiles for the so-called standard, anti-fog and double-ribbed insulators are shown in Figure 2 and Figure 3. Table 1 Geometrical parameters of Russian insulators used for the calculations. Insulator type Insulator profile Mechanical load [kn] Creepage [mm] Axial length [mm] PS 40 Standard PSV 40 Anti-fog PSD 70 Double ribbed PSV 70 Anti-fog PS 120 Standard PSV 120 Anti-fog PSV 160 Anti-fog PSV 210 Anti-fog PS 300 Standard Figure 2 Example of standard profile (left) and anti-fog profile (right) for 120 kn insulator. Figure 3 Example of double-ribbed profile for 70 kn insulator. flashover data The pollution flashover data from [6] is presented in Table 9-2 as constants (A and α) of the approximation curves U 50% =A SDD -α, where U 50% is 50%-flashover voltage per insulator and ESDD is the Salt Deposit Density. The test method was Solid Layer according IEC 60507; the only difference was NSDD close to 3 mg/cm 2. Table 2 Approximation constants for the pollution flashover laboratory data of Russian insulators. Insulator Insulator type profile A [kv/m] α PS 40 Standard 17,4 0,271 PSV 40 Anti-fog 31,8 0,322 PSD 70 Double-ribbed 37,0 0,415 PSV 70 Anti-fog 39,2 0,391 PS 120 Standard 35,4 0,421 PSV 120 Anti-fog 39,2 0,390 PSV 160 Anti-fog 36,4 0,317 PSV 210 Anti-fog 38,9 0,358 PS 300 Standard 34,7 0,359 Input parameters for the calculations According to the latest edition of the Russian Guide materials the pollution level and the average pollution parameters (surface conductivity) are related as shown in Table 3. The ESDD is not a primarily used parameter in Russian Guide and therefore it was recalculated in Table 3 from surface conductivity (SC) as: ESDD=SCx150. This is derived from the results of measurements of both pollution parameters performed independently in Russia and in South Africa. Table 3 Relation between pollution level and pollution parameters. level Surface ESDD conductivity [µs] [mg/cm 2 ] I-Light 5 0,033 II-Medium 10 0,067 III-Heavy 20 0,133 IV-Very heavy 30 0,20 The following input parameters were used for the calculation using IST program: Standard deviation: minimum 0,3 and

3 maximum 0,4. This data is derived from Russian long-time measurements in the areas with agricultural and industrial pollution Number of events: 100. This data is typically used in Russia for evaluation of average temperate European climate, for example [3] Maximum system operation voltage for Russian overhead lines is: 126 kv for 110 kv; 252 kv for 220 kv; 362 kv for 330 kv; 525 kv for 500 kv and 787 kv for 750 kv Mean time between failures (MTBF) is 1 year which corresponds to the 1 outage per 100 km per year Typical span length is 250 m for Russian overhead lines of kv; m for overhead lines of 330 kv and 420 m for overhead lines of kv. Then 3x3x4x100(km) will give 1200 parallel insulators on 100 km of kv line; 3x3x100(km) will give 900 insulators on 100 km of 330 kv line and 2,5x3x100(km) will give 750 insulators on 100 km of kv line. Results of availability calculations The standard version of the IST 2.0 program was used for the calculations. Example of the standard IST windows is shown in Figure 4 and Figure 5. Figure 4 Example of start window in Insulator Selection Tool (IST) program. Figure 5 Illustration of the calculation in IST program for the line equipped by standard insulators PS 120. The calculations were performed for the voltage classes kv, see Table 4. The results of the calculations are compared with the recommendations of the Russian Guide as they were presented in [6]. Not all the cells of are filled in Table 4; this is due to the fact that the Russian Guide recommends certain profiles depending on the level of pollution. For example, no anti-pollution profiles are recommended for relatively clean areas, because their effectiveness is small (partial arcs often bridges the air gaps between the ribs and the creepage distance is not use 100%). Also, not all types of the insulators are recommended for all voltage classes, the mechanical class of the insulators was taken into account according to the design practice. Table 4 Required numbers of cap-and-pin insulators according to the Russian Guide and calculated by IST program (Guide/IST). Number of insulators Insulator type level I level II level III level IV 110 kv overhead lines PS 40 10/10 13/12 PSV 40 9/8 9/10 11/10 PSD 70 9/10 11/12 13/14 PSV 70 8/8 9/10 11/ kv overhead lines PS 40 20/20 24/23 PSV 40 16/16 18/19 22/21 PSD 70 16/18 21/23 26/26 PSV 70 14/15 18/20 22/ kv overhead lines PSD 70 22/24 30/32 37/38 PSV 70 20/21 26/28 32/33 PS /19 24/26 PSV /22 26/28 32/ kv overhead lines

4 PSD 70 32/36 43/47 53/54 PSV 70 29/32 38/41 46/47 PS /30 34/38 PSV /32 38/41 46/47 PSV /27 33/35 39/39 PSV /30 35/38 42/ kv overhead lines PS /42 51/57 PSV /48 56/60 69/70 PSV /40 49/51 58/58 PSV /43 52/54 63/63 PS /48 DISCUSSION The results of the calculation using IST program show very good agreement with demands of the Russian Guide. The average deviation from the demands indicated by solid line in Figure 6 is less than 10%. The deviation is calculated as the number of the required insulators obtained by the Insulator Selection Tool program divided by the number of the insulators demanded by the Guide. Thus, 1,00 means that the fit was perfect. It can be seen that the deviation for the pollution levels 1, 2 and 3 is slightly higher than for the pollution level 4. This can be explained by some inaccuracy in defined input ESDD values used for the calculations. The input ESDD levels for the pollution classes 1, 2 and 3 (see Table 3) calculated from the Russian data are still under consideration of the IEC working group and may be further corrected. Another observation is that the deviation is systematically positive, which means that the insulators are slightly over-dimensioned in comparison with the Guide and thus the selection may be further corrected by some constant. Figure 6 Deviation in the selection of the number of the insulators depending on the pollution level. The result 1,00 means perfect fit with zero deviation. EXAMPLES OF FUTURE APPLICATIONS OF THE INSULATOR SELECTION TOOL PROGRAM The IST program can be applied for different practical cases of statistical dimensioning which are briefly described below. Selection of insulation in ice&snow environment The same basic approach is used. The main pollution parameter in this case will be conductivity of the dripping water from the ice, see Figure 7. This parameter can be obtained by service measurements of the melted ice samples. The flashover voltage over the conductivity of the dripping water can be obtained in the laboratory using e.g. Ice Progressive Stress test method [9]. Example for the calculations for the freezing rain case, i.e. flashover during ice accretion, is shown in Figure 8. Figure 7 Illustration of the input parameters needed for the calculation of the risk for flashover with respect to ice&snow conditions.

5 different. This data was used for statistical dimensioning of outdoor insulation of the breakers in Scandinavia using IST program, see example in Figure 10. Figure 8 Example of availability calculation: Risk for flashover over the insulator length for the freezing rain service case for composite and glass insulators. Selection of insulation based on test station results Insulator test stations are normally equipped by leakage current measurement systems. Using leakage current data and geometrical parameters of the tested insulators, density function of pollution stress, e.g. surface conductivity can be obtained as shown in Figure 9. These are test results for a specially developed set of composite/porcelain apparatus insulators tested during 5-8 years. The results shown in Figure 9 are completely applicable for the statistical dimensioning if laboratory pollution flashover data is also available. Similar test data is at present investigated for the South African power utility ESKOM. Figure 10 Example of the normalized required pollution test severity as a function of exposure time for a certain required performance. Observe the difference in requirements for line and shunt reactor breaker. Part of the Line Performance Estimator (LPE) The IST program is the part of other STRI-developed software program called Line Performance Estimator (LPE). The LPE program calculates the total risk for flashover of the line or its section, which covers: lightning performance, pollution and ice flashover performance, switching performance. Examples of the standard LPE windows are shown in Figure 11 and Figure 12. Figure 9 Illustration of the input data for the IST calculations obtained from test station: density functions of surface conductivity. Selection of insulation with different pollution exposed time (e.g. breakers in open position) Figure 11 Example of start window in Line Performance Estimator (LPE) program. The survey of breaker energization times for different types of breakers, e.g. shunt reactor, generator, line and transformer showed that this time could be very

6 [4] V.V. Ivanov, E.A. Solomonik: Statistical flashover voltage studies of wet polluted high voltage insulators, Proceedings of ISH-1995, Graz, Austria, Aug Sept , Paper 3227 [5] C.S. Engelbrecht, R. Hartings, J. Lundquist: On the statistical dimensioning of insulators with respect to pollution conditions, IEE Proceedings - Generation, Transmission and Distribution, Volume 151, Issue 03, May 2004, p [6] D.S. Pechalin, O.V. Timofeeva, T.V. Yakovleva and V.N. Golovin, Investigation of flashover performance and establishment of the optimal areas of the use of modern glass cap-and-pin and porcelain line post insulators at overhead lines, Proceedings of TRAVEK Conference, Moscow, 2001 (in Russian) [7] L.L. Vladimirsky and E.A. Solomonik, Comparison of the specific surface conductivity and ESDD approaches to assessment of salt deposits on naturally polluted insulators, IEC 36-WG 11/Nberg/158, 2003 Figure 12 Illustration of the calculation in LPE program for line equipped by standard insulators F12/146. CONCLUSIONS The results of the statistical dimensioning using Insulator Selection Tool program show very good agreement with demands of the Russian guide for insulator selection. The deviation is less than 10%. [8] I. Gutman, R. Hartings and W.L. Vosloo, Insulation selection in the coastal Kelso area in South Africa, Proceedings of 12th ISH-2001, Bangalore, India, August 20-24, 2001, paper 5-4 [9] I. Gutman, K. Halsan and D. Hübinette: Application of Ice Progressive Stress method for selection of different insulation options, Proceedings of 13th ISH-2003, Netherlands 2003, Smit (ed.), 2003 Millpress, Rotterdam, ISBN , p. 179 [10] K. Halsan, D. Loudon, C. Engelbrecht and I. Gutman, Norwegian Utility Evaluates Insulation Alternatives to Upgrade 300 kv Transmission Network, Insulator News and Marker Report Quarterly Review, Issue 64, Quarter Two-2004, Volume 12, Number 2, 2004 The difference in the dimensioning using the IST program and the Russian Guide is explained by the difficulties in defining the ESDD value corresponding to the pollution levels from one to four. This issue is at present under consideration of the IEC TC 36 working group. A few further applications of the IST program are suggested. ACKNOWLEDGMENT The authors wish to acknowledge the contributions and support from Statnett, Svenska Kraftnät and NIIPT that made this work possible. REFERENCES [1] K. Halsan, D. Loudon, C. Engelbrecht and I. Gutman, Ice and pollution testing of compact insulator strings in Statnett, 2003 World Conference on Insulators, Arresters & Bushings, Marbela, Spain, November 16-19, 2003 [2] Guide : A guide for selection of outdoor insulation of electrical installations, Moscow, 1990 (in Russian) [3] N.N. Tikhodeev; S.S. Shur: Insulation of electrical network, Leningrad, Energy, 1979 (in Russian)

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION IEC TS 61245 Edition 2.0 2015-03 Artificial pollution tests on high-voltage ceramic and glass insulators to be used on d.c. systems INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS

More information

Nordel GRID DISTURBANCE AND FAULT STATISTICS

Nordel GRID DISTURBANCE AND FAULT STATISTICS Nordel GRID DISTURBANCE AND FAULT STATISTICS Table contents Table contents Page 1 Introduction... 3 1.1 Contact persons... 4 1.2 Guidelines the statistics... 4 1.3 Voltage levels in the Nordel network...

More information

NORDIC AND BALTIC GRID DISTURBANCE STATISTICS 2014

NORDIC AND BALTIC GRID DISTURBANCE STATISTICS 2014 NORDIC AND BALTIC GRID DISTURBANCE STATISTICS 2014 21.10.2015 REGIONAL GROUP NORDIC 1 INTRODUCTION... 4 1.1 DESCRIPTION OF THE REPORT... 4 1.2 CONTACT PERSONS... 5 1.3 VOLTAGE LEVELS IN THE NORDIC AND

More information

Recent Advances in Transmission Insulators Prof.B. Subba Reddy Department of Electrical Engineering Indian Institute of Science Bangalore

Recent Advances in Transmission Insulators Prof.B. Subba Reddy Department of Electrical Engineering Indian Institute of Science Bangalore Recent Advances in Transmission Insulators Prof.B. Subba Reddy Department of Electrical Engineering Indian Institute of Science Bangalore Module No # 02 Lecture No # 07 Environment issues with of Transmission

More information

C I R E D 18 th International Conference on Electricity Distribution Turin, 6 th to 9 th June 2005

C I R E D 18 th International Conference on Electricity Distribution Turin, 6 th to 9 th June 2005 RELIABILITY AND LONG TIME BEHAVIOUR OF MV-DISTRIBUTION SWITCHGEAR IN SEVERE ENVIRONMENTAL CONDITIONS - EXAMINATION OF SF 6 -INSULATED RING MAIN UNITS (RMU) UP TO 20 YEARS IN SERVICE. B. I. Oftedal, Siemens

More information

About ABB Micafil Facts

About ABB Micafil Facts About ABB Micafil Facts Location Zurich Employees ~ 200 Switzerland Revenues 2008 85 MUSD Production area 11 000 m 2 Export > 80%. About ABB Micafil History 1918 1939 1946 1960 1970 1972 1993 1996 1998

More information

Development and Evolution of an Asset Management Organization

Development and Evolution of an Asset Management Organization Development and Evolution of an Asset Management Organization Art Kruppenbacher Manager Asset Management October 21, 2015 About the Iberdrola Group Headquartered in Spain 109-year history 28,000 employees

More information

Innovation Electrical Industry

Innovation Electrical Industry Position Paper Potential for Optimising the Use of SF6 in Switchgear Automotive Industry 4.0 Energy Efficiency Digitalisation 4.0 Innovation Electrical Industry 16 November 2016 ZVEI German Electrical

More information

DISSOLVED GAS ANALYSIS OF NATURAL ESTER FLUIDS UNDER ELECTRICAL AND THERMAL STRESS

DISSOLVED GAS ANALYSIS OF NATURAL ESTER FLUIDS UNDER ELECTRICAL AND THERMAL STRESS DISSOLVED GAS ANALYSIS OF NATURAL ESTER FLUIDS UNDER ELECTRICAL AND THERMAL STRESS M. Jovalekic 1*, D. Vukovic 1 and S. Tenbohlen 1 1 Institute of Power Transmission and High Voltage Technology (IEH) University

More information

Modelling of Extreme Waves Related to Stability Research

Modelling of Extreme Waves Related to Stability Research Modelling of Extreme Waves Related to Stability Research Janou Hennig 1 and Frans van Walree 1 1. Maritime Research Institute Netherlands,(MARIN), Wageningen, the Netherlands Abstract: The paper deals

More information

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter

Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter Nitrogen subtraction on reported CO 2 emission using ultrasonic flare gas meter Kjell-Eivind Frøysa, Christian Michelsen Research AS, Bergen, Norway Henning Ekerhovd, StatoilHydro ASA, Kollsnes, Norway

More information

arxiv: v1 [physics.ins-det] 16 Aug 2014

arxiv: v1 [physics.ins-det] 16 Aug 2014 Preprint typeset in JINST style - HYPER VERSION RPC Gap Production and Performance for CMS RE4 Upgrade arxiv:1408.3720v1 [physics.ins-det] 16 Aug 2014 Sung Keun Park, Min Ho Kang and Kyong Sei Lee Korea

More information

CFD AND EXPERIMENTAL STUDY OF AERODYNAMIC DEGRADATION OF ICED AIRFOILS

CFD AND EXPERIMENTAL STUDY OF AERODYNAMIC DEGRADATION OF ICED AIRFOILS Colloquium FLUID DYNAMICS 2008 Institute of Thermomechanics AS CR, v.v.i., Prague, October 22-24, 2008 p.1 CFD AND EXPERIMENTAL STUDY OF AERODYNAMIC DEGRADATION OF ICED AIRFOILS Vladimír Horák 1, Dalibor

More information

Comparison on Wind Load Prediction of Transmission Line between Chinese New Code and Other Standards

Comparison on Wind Load Prediction of Transmission Line between Chinese New Code and Other Standards Available online at www.sciencedirect.com Procedia Engineering 14 (011) 1799 1806 The Twelfth East Asia-Pacific Conference on Structural Engineering and Construction Comparison on Wind Load Prediction

More information

KMU SUBSTATION WORKSHOP

KMU SUBSTATION WORKSHOP Rick Aguilar, Director of Job Training & Safety KMU SUBSTATION WORKSHOP JUNE 29-30, 2016 OTTAWA, KS Hazards & Safety Rules Qualified Personnel & Task-Based Hazard Mitigation Worksite Applications & Considerations

More information

Roundabouts along Rural Arterials in South Africa

Roundabouts along Rural Arterials in South Africa Krogscheepers & Watters 0 0 Word count: 00 text + figures = 0 equivalent words including Title and Abstract. Roundabouts along Rural Arterials in South Africa Prepared for: rd Annual Meeting of Transportation

More information

You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services

You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services Why Failures Occur Insulation Failure - Every electrical component is comprised of

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration

Paper 2.2. Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration Paper 2.2 Operation of Ultrasonic Flow Meters at Conditions Different Than Their Calibration Mr William Freund, Daniel Measurement and Control Mr Klaus Zanker, Daniel Measurement and Control Mr Dale Goodson,

More information

" High Voltage Switch Yards & How Safe are these really" <Peter Rhodes> <Principal and High Voltage Solution. Com Ltd>

 High Voltage Switch Yards & How Safe are these really <Peter Rhodes> <Principal and High Voltage Solution. Com Ltd> " High Voltage Switch Yards & How Safe are these really" High Voltage Forum Brisbane 2013 Duty of Care As part of an asset owner Duty of care

More information

Infrared Thermography Inspection Guidelines. Date Issued:

Infrared Thermography Inspection Guidelines. Date Issued: Infrared Thermography Inspection Guidelines Date Issued: 2002 01 29 Created By: Approved By: L. Henderson G. Durnford Table Of Contents Table Of Contents...i POLICY STATEMENT...1 APPLICABLE INTERNATIONAL

More information

Using Perfluorocarbon Tracers (PFT) for detecting oil leakages in LPOF cable systems. J.C.M. VAN ROSSUM * Prysmian Group NL The Netherlands

Using Perfluorocarbon Tracers (PFT) for detecting oil leakages in LPOF cable systems. J.C.M. VAN ROSSUM * Prysmian Group NL The Netherlands 21, rue d Artois, F-75008 PARIS CIGRE US National Committee 2012 Grid of the Future Symposium http : //www.cigre.org Using Perfluorocarbon Tracers (PFT) for detecting oil leakages in LPOF cable systems

More information

P Oskarshamn site investigation. Borehole: KAV01 Results of tilt testing. Panayiotis Chryssanthakis Norwegian Geotechnical Institute, Oslo

P Oskarshamn site investigation. Borehole: KAV01 Results of tilt testing. Panayiotis Chryssanthakis Norwegian Geotechnical Institute, Oslo P-04-42 Oskarshamn site investigation Borehole: KAV01 Results of tilt testing Panayiotis Chryssanthakis Norwegian Geotechnical Institute, Oslo March 2004 Svensk Kärnbränslehantering AB Swedish Nuclear

More information

Guidelines to the standard IEC60601

Guidelines to the standard IEC60601 EUROPEAN POWER SUPPLY MANUFACTURERS ASSOCIATION (Visit the EPSMA website at www.epsma.org) Medical Approvals for Power Supplies Guidelines to the standard IEC60601 Revision Date: 2009-09-12 This document

More information

Optimized Maintenance Planning for Transmission Power Systems.

Optimized Maintenance Planning for Transmission Power Systems. Optimized aintenance Planning for Transmission Power Systems. Improvement of the condition indexing process Name : - Adesh Soemeer Thesis committee: - Prof. dr. Johan Smit - Ing. Peter Oomens (Joulz) -

More information

Dynamic Network Behavior of Offshore Wind Parks

Dynamic Network Behavior of Offshore Wind Parks Dynamic Network Behavior of Offshore Wind Parks Thomas Ahndorf, M.Eng. Prof. Dr.-Ing. Rolf Witzmann TU- München Associated Institute of Power Transmission Systems 80333 Munich, Germany E-Mail: thomas.ahndorf@mytum.de

More information

Advanced Test Equipment Rentals ATEC (2832) OMS 600

Advanced Test Equipment Rentals ATEC (2832) OMS 600 Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMS 600 Continuous partial discharge monitoring system for power generators and electrical motors Condition monitoring

More information

Analysis of Shear Lag in Steel Angle Connectors

Analysis of Shear Lag in Steel Angle Connectors University of New Hampshire University of New Hampshire Scholars' Repository Honors Theses and Capstones Student Scholarship Spring 2013 Analysis of Shear Lag in Steel Angle Connectors Benjamin Sawyer

More information

Power Unit 075. Maintain Substation Circuit Breakers

Power Unit 075. Maintain Substation Circuit Breakers Power Unit 075 Maintain Substation Circuit Breakers The specification details the required skills, knowledge and behaviours to establish competence to carry out the maintenance of high voltage power circuit

More information

HiPerMax LuK tooth chain for transmissions Reliable Power Flow in the Drive Train

HiPerMax LuK tooth chain for transmissions Reliable Power Flow in the Drive Train HiPerMax LuK tooth chain for transmissions Reliable Power Flow in the Drive Train Andreas Englisch Michael Pichura LuK SYMPOSIUM 2006 87 6 LuK tooth chain for transmissions Introduction A modern drive

More information

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience - Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience - Dr. Wolfgang Jockel, Martin Schneider, TÜV Rheinland Group, D-51105 Cologne / Germany 1. Introduction A new basis for the certification

More information

Online DGA-monitoring of power transformers

Online DGA-monitoring of power transformers Online DGA-monitoring of power transformers Senior Industry Expert, Vaisala Finland Member of CIGRE A2/D1.47 and D1.52 WGs April 2018 Vaisala Webinar content 1. Dissolved gases why and which gases 2. Fault

More information

Determination of the Design Load for Structural Safety Assessment against Gas Explosion in Offshore Topside

Determination of the Design Load for Structural Safety Assessment against Gas Explosion in Offshore Topside Determination of the Design Load for Structural Safety Assessment against Gas Explosion in Offshore Topside Migyeong Kim a, Gyusung Kim a, *, Jongjin Jung a and Wooseung Sim a a Advanced Technology Institute,

More information

MODERN APPROACH FOR CONDITION MONITORING OF POWER TRANSFORMERS USING DISSOLVED GAS ANALYSIS

MODERN APPROACH FOR CONDITION MONITORING OF POWER TRANSFORMERS USING DISSOLVED GAS ANALYSIS MODERN APPROACH FOR CONDITION MONITORING OF POWER TRANSFORMERS USING DISSOLVED GAS ANALYSIS Zohra Khan 1, Avinash Paranjpe 2 1 ME Student, Electrical Power System, PES COE/ Dr. B.A.M. University, (India)

More information

Predicting Medium-Voltage Underground-Distribution Cable Failures John P. Ainscough P. E., Member IEEE Ian W. Forrest P. E.

Predicting Medium-Voltage Underground-Distribution Cable Failures John P. Ainscough P. E., Member IEEE Ian W. Forrest P. E. Predicting Medium-Voltage Underground-Distribution Cable Failures Nov. 11, 2009, Scottsdale, AZ Introduction The Birth of Suburbia - Starting in the 1950 s White House Conference on Natural Beauty Discussion

More information

TECHNICAL PAPER PRESENTATION

TECHNICAL PAPER PRESENTATION 1 W E L C O M E T O A C O M E T 2 0 1 7 TECHNICAL PAPER PRESENTATION 2 INSULATION AND SWITCHING IN ENVIRONMENTALLY FRIENDLY GASES BY JAVIER MANTILLA 3 A B O U T T H E A U T H O R BRIEF BIO JAVIER MANTILLA

More information

Testing Distribution Switchgear for Partial Discharge

Testing Distribution Switchgear for Partial Discharge Testing Distribution Switchgear for Partial Discharge Mr. Neil Davies Affiliation: EA Technology Ltd, UK; neil.davies@eatechnology.com ABSTRACT Over the past 30 years handheld instrumentation has been

More information

Safety and Design Alternatives for Two-Way Stop-Controlled Expressway Intersections

Safety and Design Alternatives for Two-Way Stop-Controlled Expressway Intersections Safety and Design Alternatives for Two-Way Stop-Controlled Expressway Intersections Thomas H. Maze Center for Transportation Research and Education Iowa State University 2901 South Loop Drive, Suite 3100

More information

PARAMETRIZATION OF WAVE TRANSFORMATION ABOVE SUBMERGED BAR BASED ON PHYSICAL AND NUMERICAL TESTS

PARAMETRIZATION OF WAVE TRANSFORMATION ABOVE SUBMERGED BAR BASED ON PHYSICAL AND NUMERICAL TESTS Proceedings of the 6 th International Conference on the Application of Physical Modelling in Coastal and Port Engineering and Science (Coastlab16) Ottawa, Canada, May 10-13, 2016 Copyright : Creative Commons

More information

TR Test Report Complementary Testing RKN e1 Container (+5 C) Protection by Insulation Version: 01 Page: 2 (22)

TR Test Report Complementary Testing RKN e1 Container (+5 C) Protection by Insulation Version: 01 Page: 2 (22) RKN e1 Container (+5 C) Protection by Insulation Version: 01 Page: 2 (22) Document History Version Date of issue Revision(s) Issued by 01 16OCT2012 N/A (First version of document) David Graaf, Envirotainer

More information

Tightening Evaluation of New 400A Size Metal Gasket

Tightening Evaluation of New 400A Size Metal Gasket Proceedings of the 8th International Conference on Innovation & Management 307 Tightening Evaluation of New 400A Size Metal Gasket Moch. Agus Choiron 1, Shigeyuki Haruyama 2, Ken Kaminishi 3 1 Doctoral

More information

Evaluation passenger car unit for motorcycle in Indonesia Highway Capacity Manual (Case study: Bandung and Semarang)

Evaluation passenger car unit for motorcycle in Indonesia Highway Capacity Manual (Case study: Bandung and Semarang) Evaluation passenger car unit for motorcycle in Indonesia Highway Capacity Manual (Case study: Bandung and Semarang) Najid 1,* 1 Tarumanegara University, Department Civil Engineering, Jakarta, Indonesia

More information

Reference wind speed anomaly over the Dutch part of the North Sea

Reference wind speed anomaly over the Dutch part of the North Sea Reference wind speed anomaly over the Dutch part of the North Sea A.J. Brand This report has been presented at the European Offshore Wind 2009 Conference, Stockholm, 4-6 September, 2009 ECN-M--09-28 2

More information

CONTROL and INSTRUMENTATION

CONTROL and INSTRUMENTATION CONTROL and INSTRUMENTATION COURSE 500: 5 DAYS: Max 8 Candidates This course covers the key aspects of current instrumentation and process control technology and is designed to enable maintenance personnel

More information

WP2 Fire test for toxicity of fire effluents

WP2 Fire test for toxicity of fire effluents Pagina 3 di 89 TRA SFEU VTT 22.6.2009 v.2 WP2 Fire test for toxicity of fire effluents Task 2.1.2 Development of small-scale test method for fire effluents Step 1: Use of modeling Plans according to DoW:

More information

Investigating the effects of interchanging components used to perform ripple assessments on calibrated vector network analysers

Investigating the effects of interchanging components used to perform ripple assessments on calibrated vector network analysers Abstract Investigating the effects of interchanging components used to perform ripple assessments on calibrated vector network analysers Andrew G Morgan and Nick M Ridler Centre for Electromagnetic and

More information

EFFECTS OF SIDEWALL OPENINGS ON THE WIND LOADS ON PIPE-FRAMED GREENHOUSES

EFFECTS OF SIDEWALL OPENINGS ON THE WIND LOADS ON PIPE-FRAMED GREENHOUSES The Seventh Asia-Pacific Conference on Wind Engineering, November 8-12, 29, Taipei, Taiwan EFFECTS OF SIDEWALL OPENINGS ON THE WIND LOADS ON PIPE-FRAMED GREENHOUSES Yasushi Uematsu 1, Koichi Nakahara 2,

More information

Queue analysis for the toll station of the Öresund fixed link. Pontus Matstoms *

Queue analysis for the toll station of the Öresund fixed link. Pontus Matstoms * Queue analysis for the toll station of the Öresund fixed link Pontus Matstoms * Abstract A new simulation model for queue and capacity analysis of a toll station is presented. The model and its software

More information

Plaice (Pleuronectes platessa) in Division 7.e (western English Channel)

Plaice (Pleuronectes platessa) in Division 7.e (western English Channel) Celtic Seas and Greater North Sea ecoregions Published 30 June 2016 Version 2: 15 May 2017 5.3.51 Plaice (Pleuronectes platessa) in Division 7.e (western English Channel) ICES stock advice ICES advises

More information

Inspection Recommendations

Inspection Recommendations S&C Vista SD Underground Distribution Switchgear Pad-Mounted and Vault-Mounted Styles Outdoor Distribution (17.5 kv and 29 kv) With Visi-Gap Load Interrupter Switches and Visi-Gap Fault Inetrrupters Inspection

More information

Axpo Power Ltd. 2) GE Grid Solutions

Axpo Power Ltd. 2) GE Grid Solutions PS 3 SF6-free 123 kv Substation Solution to meet Axpo s sustainability strategy C. LINDNDER 1), D. GAUTSCHI 2) 1) Axpo Power Ltd. 2) GE Grid Solutions SUMMARY As it is the strategic goal of Axpo Power

More information

Evaluation of Effectiveness and Safety of CO 2 Cleaning of Energized Contaminated Pad-Mounted Gear

Evaluation of Effectiveness and Safety of CO 2 Cleaning of Energized Contaminated Pad-Mounted Gear 1 Evaluation of Effectiveness and Safety of CO 2 Cleaning of Energized Contaminated Pad-Mounted Gear Peter Tyschenko Manager, Distribution Standards Commonwealth Edison Company Shay Bahramirad and Terry

More information

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12

LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/12 LOW PRESSURE EFFUSION OF GASES revised by Igor Bolotin 03/05/ This experiment will introduce you to the kinetic properties of low-pressure gases. You will make observations on the rates with which selected

More information

Service Test Unit for ROSS Proportional Valves RESK

Service Test Unit for ROSS Proportional Valves RESK Service Unit for Proportional Valves Page 1 Technical Description ROSS 04.08.2015 Service Test Unit for ROSS Proportional Valves Technical Description V 1.0 / 2015 RESK 4591.40 For all Prop Valve Models

More information

EXAMINING THE EFFECT OF HEAVY VEHICLES DURING CONGESTION USING PASSENGER CAR EQUIVALENTS

EXAMINING THE EFFECT OF HEAVY VEHICLES DURING CONGESTION USING PASSENGER CAR EQUIVALENTS EXAMINING THE EFFECT OF HEAVY VEHICLES DURING CONGESTION USING PASSENGER CAR EQUIVALENTS Ahmed Al-Kaisy 1 and Younghan Jung 2 1 Department of Civil Engineering, Montana State University PO Box 173900,

More information

REQUIREMENTS AND HAND-OVER DOCUMENTATION FOR ENERGY-OPTIMAL DEMAND-CONTROLLED VENTILATION

REQUIREMENTS AND HAND-OVER DOCUMENTATION FOR ENERGY-OPTIMAL DEMAND-CONTROLLED VENTILATION REQUIREMENTS AND HAND-OVER DOCUMENTATION FOR ENERGY-OPTIMAL DEMAND-CONTROLLED VENTILATION Mads Mysen* 1, Axel Cablé 1, Peter G. Schild 1, and Kari Thunshelle 1 1 SINTEF Building and Infrastructure Forskningsveien

More information

ISO 1977 INTERNATIONAL STANDARD. Conveyor chains, attachments and sprockets. Chaînes de manutention, plaques-attaches et roues dentées

ISO 1977 INTERNATIONAL STANDARD. Conveyor chains, attachments and sprockets. Chaînes de manutention, plaques-attaches et roues dentées INTERNATIONAL STANDARD ISO 1977 Second edition 2006-08-15 Conveyor chains, attachments and sprockets Chaînes de manutention, plaques-attaches et roues dentées Reference number ISO 1977:2006(E) ISO 2006

More information

ISO 6570 INTERNATIONAL STANDARD. Natural gas Determination of potential hydrocarbon liquid content Gravimetric methods

ISO 6570 INTERNATIONAL STANDARD. Natural gas Determination of potential hydrocarbon liquid content Gravimetric methods INTERNATIONAL STANDARD ISO 6570 First edition 2001-06-15 Natural gas Determination of potential hydrocarbon liquid content Gravimetric methods Gaz naturel Détermination de la teneur en hydrocarbures liquides

More information

BUYER S GUIDE AQUAlogger 530WTD

BUYER S GUIDE AQUAlogger 530WTD OCEAN & ENVIRONMENTAL BUYER S GUIDE AQUAlogger 530WTD Wireless Temperature and Depth Logger AQUAlogger 530WTD The AQUAlogger 530WTD has an innovative design that includes the ability to transfer stored

More information

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version

User Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version User Manual Heads-Up Display (HUD) Mechanical Button Version DiveCAN Table of Contents 1. Introduction...4 1.1 Features...4 2. Physical Description...5 3. Reading the PPO2...6 3.1 Modified Smither s Code...7

More information

CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ. Semester 2 Examinations 2010

CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ. Semester 2 Examinations 2010 CORK INSTITUTE OF TECHNOLOGY INSTITIÚID TEICNEOLAÍOCHTA CHORCAÍ Semester 2 Examinations 2010 School: Mechanical & Process Engineering Programme Title: Bachelor of Science (Honours) in Advanced Manufacturing

More information

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter

Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)

More information

Assessment of correlations between NDE parameters and tube structural integrity for PWSCC at U-bends

Assessment of correlations between NDE parameters and tube structural integrity for PWSCC at U-bends Assessment of correlations between NDE parameters and tube structural integrity for PWSCC at U-bends S. Bakhtiari, T. W. Elmer, Z. Zeng and S. Majumdar Nuclear Engineering Division Argonne National Laboratory

More information

BUYER S GUIDE AQUAlogger 520

BUYER S GUIDE AQUAlogger 520 OCEAN & ENVIRONMENTAL BUYER S GUIDE AQUAlogger 520 Mini Temperature and Pressure Logger AQUAlogger 520 Aquatec s primary temperature and depth model, the AQUAlogger 520, combines years of product development

More information

ARC FLASH HAZARD ANALYSIS

ARC FLASH HAZARD ANALYSIS I. ARC FLASH HAZARD ANALYSIS IS REQUIRED ARC FLASH HAZARD ANALYSIS By Mike Lang Principal Field Engineer OSHA s 29 CFR Part 1910.132(d) states: The employer shall assess the workplace to determine if hazards

More information

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven.

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven. Reference series Composite leading indicators OECD Composite Leading Indicators AREA TOTALS 7-03- 19 OECD Total 19 OECD + Major 6 Non Member Countries 19 Major Seven 19 Major Five Asia 19 Euro area 19

More information

Pedestrian crossings survey in Europe

Pedestrian crossings survey in Europe Pedestrian crossings survey in Europe Introduction The issue of accidents on pedestrian crossings is highly emotional and raises a very strong interest within the public opinion and the media, mainly because

More information

CERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB Audio, video and similar electronic apparatus Safety requirements

CERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB Audio, video and similar electronic apparatus Safety requirements Page 1 of 7 CERTIFICATION IMPACT ANALYSIS: IEC 60065, SEVENTH EDITION vs. GB 8898 2011 Audio, video and similar electronic apparatus Safety requirements This analysis is intended to identify and analyze

More information

THE HORNS REV WIND FARM AND THE OPERATIONAL EXPERIENCE WITH THE WIND FARM MAIN CONTROLLER

THE HORNS REV WIND FARM AND THE OPERATIONAL EXPERIENCE WITH THE WIND FARM MAIN CONTROLLER Copenhagen Offshore Wind 25, 26-28 October 25 1 THE HORNS REV WIND FARM AND THE OPERATIONAL EXPERIENCE WITH THE WIND FARM MAIN CONTROLLER Jesper Runge Kristoffersen M.Sc.EE Elsam Engineering A/S, Kraftværksvej

More information

LIFE TIME OF FREAK WAVES: EXPERIMENTAL INVESTIGATIONS

LIFE TIME OF FREAK WAVES: EXPERIMENTAL INVESTIGATIONS Proceedings of the 6 th International Conference on the Application of Physical Modelling in Coastal and Port Engineering and Science (Coastlab16) Ottawa, Canada, May 10-13, 2016 Copyright : Creative Commons

More information

ROUNDABOUT CAPACITY: THE UK EMPIRICAL METHODOLOGY

ROUNDABOUT CAPACITY: THE UK EMPIRICAL METHODOLOGY ROUNDABOUT CAPACITY: THE UK EMPIRICAL METHODOLOGY 1 Introduction Roundabouts have been used as an effective means of traffic control for many years. This article is intended to outline the substantial

More information

ASSESSING THE RELIABILITY OF FAIL-SAFE STRUCTURES INTRODUCTION

ASSESSING THE RELIABILITY OF FAIL-SAFE STRUCTURES INTRODUCTION ASSESSING THE RELIABILITY OF FAIL-SAFE STRUCTURES Abraham Brot * Abstract: A computer simulation method is described, that can be used to assess the reliability of a dual-path fail-safe design. The method

More information

Cod (Gadus morhua) in subdivisions 24 32, eastern Baltic stock (eastern Baltic Sea) *

Cod (Gadus morhua) in subdivisions 24 32, eastern Baltic stock (eastern Baltic Sea) * ICES Advice on fishing opportunities, catch, and effort Baltic Sea Ecoregion Published 31 May 2017 Version 2: 1 June 2017 Version 3: 8 June 2017 Version 4: 8 March 2018 DOI: 10.17895/ices.pub.3096 Cod

More information

Residual Stresses in Railway Axles

Residual Stresses in Railway Axles Residual Stresses in Railway Axles ŘEHA BOHUSLAV 1,a,*, VÁCLAVÍK JAROSLAV 2,b NÁVRAT TOMÁŠ 3,c and DAVID HALABUK 3,d 1 GHH-BONATRANS GROUP a.s., Revoluční 1234, 735 94 Bohumín, Czech Republic 2 Výzkumný

More information

Micro Motion 3098 Gas Specific Gravity Meter

Micro Motion 3098 Gas Specific Gravity Meter Product Data Sheet PS-001188, Rev. B April 2009 Micro Motion 3098 Gas Specific Gravity Meter Micro Motion density and concentration meters are built to tackle the most demanding process and fiscal applications.

More information

COOPER POWER. SERIES VariSTAR type composite light-duty under-oil (CLU) MOV arrester installation instructions. Surge Arresters MN235023EN

COOPER POWER. SERIES VariSTAR type composite light-duty under-oil (CLU) MOV arrester installation instructions. Surge Arresters MN235023EN Surge Arresters MN235023EN Effective November 2016 Supersedes October 2006 (S235-95-1) COOPER POWER SERIES VariSTAR type composite light-duty under-oil (CLU) MOV arrester installation instructions HIGH

More information

Aerodynamic Performance of Trains with Different Longitudinal Section Lines under Crosswind

Aerodynamic Performance of Trains with Different Longitudinal Section Lines under Crosswind 2017 2nd International Conference on Industrial Aerodynamics (ICIA 2017) ISBN: 978-1-60595-481-3 Aerodynamic Performance of Trains with Different Longitudinal Section Lines under Crosswind Taizhong Xie

More information

CORESTA RECOMMENDED METHOD N 6

CORESTA RECOMMENDED METHOD N 6 CORESTA RECOMMENDED METHOD N 6 DETERMINATION OF VENTILATION DEFINITIONS AND MEASUREMENT PRINCIPLES (2015 Revision September 2016) 1. SCOPE This CORESTA Recommended Method specifies a method for the determination

More information

ISO INTERNATIONAL STANDARD. Fluid power systems O-rings Part 2: Housing dimensions for general applications

ISO INTERNATIONAL STANDARD. Fluid power systems O-rings Part 2: Housing dimensions for general applications INTERNATIONAL STANDARD ISO 3601-2 First edition 2008-06-15 Fluid power systems O-rings Part 2: Housing dimensions for general applications Transmissions hydrauliques et pneumatiques Joints toriques Partie

More information

TECHNICAL DIAGNOSTICS FOR POWER APPARATUS. H. Sander, J. Schwab, M. Muhr

TECHNICAL DIAGNOSTICS FOR POWER APPARATUS. H. Sander, J. Schwab, M. Muhr TECHNICAL DIAGNOSTICS FOR POWER APPARATUS H. Sander, J. Schwab, M. Muhr Kärntner Elektrizitäts-AG, Grazer Stadtwerke, Technische Universität Graz, Austria Summary In the deregulating environment facing

More information

Modeling of thin strip profile during cold rolling on roll crossing and shifting mill

Modeling of thin strip profile during cold rolling on roll crossing and shifting mill University of Wollongong Research Online Faculty of Engineering and Information Sciences - Papers: Part A Faculty of Engineering and Information Sciences 2013 Modeling of thin strip profile during cold

More information

MINUTES OF MEETING BUSHING SUBCOMMITTEE OF THE IEEE/PES TRANSFORMER COMMITTEE MINNEAPLOS, MN OCT 17, 2007

MINUTES OF MEETING BUSHING SUBCOMMITTEE OF THE IEEE/PES TRANSFORMER COMMITTEE MINNEAPLOS, MN OCT 17, 2007 MINUTES OF MEETING BUSHING SUBCOMMITTEE OF THE IEEE/PES TRANSFORMER COMMITTEE MINNEAPLOS, MN OCT 17, 2007 8.9 Bushing Subcommittee Fred Elliott, Chair 8.9.1 Introduction/Attendance Fred Elliott - Chair

More information

Competition Jumping Horses: Effects of Age, Sex and Breed on the Fei/Wbfsh World Ranking

Competition Jumping Horses: Effects of Age, Sex and Breed on the Fei/Wbfsh World Ranking Competition Jumping Horses: Effects of Age, Sex and Breed on the Fei/Wbfsh World Ranking Anca ROMAN-POPOVICI *, Dan SUMOVSCHI, Ioan GÎLCĂ Faculty of Animal Science, University of Agricultural Science and

More information

Gas insulated wall bushing, type GGFL Installation and maintenance guide

Gas insulated wall bushing, type GGFL Installation and maintenance guide 2770 501-8 en, Rev. 3 Gas insulated wall bushing, type GGFL Installation and maintenance guide This document must not be copied without our written permission, and the contents thereof must not be imparted

More information

Micafil RIP bushings High-voltage Resin Impregnated Paper bushings. Power and productivity for a better world TM ABB

Micafil RIP bushings High-voltage Resin Impregnated Paper bushings. Power and productivity for a better world TM ABB Micafil RIP bushings High-voltage Resin Impregnated Paper bushings Power and productivity for a better world TM ABB Leading in Bushings Technology: ABB Micafil ABB Micafil has been closely associated with

More information

Power Transformer Maintenance. Maintenance Practices & Procedures for Substation Class Distribution Power Transformers

Power Transformer Maintenance. Maintenance Practices & Procedures for Substation Class Distribution Power Transformers Maintenance Practices & Procedures for Substation Class Distribution Power Transformers Why should special maintenance practices be applied to power transformers? Power transformers utilize active cooling

More information

Guide for the Sampling of Oil from Trench COTA Bushings for DGA

Guide for the Sampling of Oil from Trench COTA Bushings for DGA Instruction Guide for the Sampling of Oil from Trench COTA Bushings for DGA Forward This instruction is protected by copyright. Imparting to any third party and reproduction of any kind without written

More information

New IEC and Site Conditions in Reality

New IEC and Site Conditions in Reality New IEC 61400-1 and Site Conditions in Reality Udo Follrichs Windtest Kaiser-Wilhelm-Koog GmbH Sommerdeich 14b, D-25709 Kaiser-Wilhelm-Koog Tel.: +49-4856-901-0, Fax: +49-4856-901-49 Axel Andreä, Kimon

More information

(TRCM) Wire Wound RF SMD Inductor

(TRCM) Wire Wound RF SMD Inductor Version: February 17, 2017 (TRCM) Wire Wound RF SMD Inductor Token Electronics Industry Co., Ltd. Web: www.token.com.tw Email: rfq@token.com.tw Taiwan: No.137, Sec. 1, Zhongxing Rd., Wugu District, New

More information

Comparing the calculated coefficients of performance of a class of wind turbines that produce power between 330 kw and 7,500 kw

Comparing the calculated coefficients of performance of a class of wind turbines that produce power between 330 kw and 7,500 kw World Transactions on Engineering and Technology Education Vol.11, No.1, 2013 2013 WIETE Comparing the calculated coefficients of performance of a class of wind turbines that produce power between 330

More information

B kv pilot installation with a ketone based insulation gas with first experience from operation in the grid. D. TEHLAR ABB - Switzerland

B kv pilot installation with a ketone based insulation gas with first experience from operation in the grid. D. TEHLAR ABB - Switzerland 2016 Paris Session http : //www.cigre.org B3-105 170 kv pilot installation with a ketone based insulation gas with first experience from operation in the grid T. DIGGELMANN ABB - Switzerland D. TEHLAR

More information

Micafil RIP bushings High-voltage Resin-Impregnated Paper bushings. Power and productivity for a better world TM ABB

Micafil RIP bushings High-voltage Resin-Impregnated Paper bushings. Power and productivity for a better world TM ABB Micafil RIP bushings High-voltage Resin-Impregnated Paper bushings Power and productivity for a better world TM ABB Leading in Bushings Technology ABB Switzerland Ltd has been closely associated with innovation

More information

Introduction to Roundabout Analysis Using ARCADY

Introduction to Roundabout Analysis Using ARCADY Introduction to Roundabout Analysis Using ARCADY Toronto SimCap User Group Technical Event and ITE Toronto Section Social Event July 22, 2014 Phil Weber, P.Eng. GHD Inc. (The Home of Ourston Roundabout

More information

CS10 # Network Safety Performance Objectives (2016)

CS10 # Network Safety Performance Objectives (2016) CS10 #4384287 Network Safety Performance Objectives (2016) Context & Purpose The Horizon Power Network Safety Objectives (2016) (Objective Statement) has been prepared for each of network safety performance

More information

ESTIMATION OF THE DESIGN WIND SPEED BASED ON

ESTIMATION OF THE DESIGN WIND SPEED BASED ON The Seventh Asia-Pacific Conference on Wind Engineering, November 8-12, 2009, Taipei, Taiwan ESTIMATION OF THE DESIGN WIND SPEED BASED ON UNCERTAIN PARAMETERS OF THE WIND CLIMATE Michael Kasperski 1 1

More information

Control Strategies for operation of pitch regulated turbines above cut-out wind speeds

Control Strategies for operation of pitch regulated turbines above cut-out wind speeds Control Strategies for operation of pitch regulated turbines above cut-out wind speeds Helen Markou 1 Denmark and Torben J. Larsen, Risø-DTU, P.O.box 49, DK-4000 Roskilde, Abstract The importance of continuing

More information

Row / Distance from centerline, m. Fan side Distance behind spreader, m 0.5. Reference point. Center line

Row / Distance from centerline, m. Fan side Distance behind spreader, m 0.5. Reference point. Center line 1 Standardisation of test method for salt spreader: Air flow experiments Report 7: Effect of crosswind on salt distribution by Jan S. Strøm, Consultant Aarhus University, Engineering Centre Bygholm, Test

More information

P.O.Box 43 Blindern, 0313 Oslo, Norway Tel.: , Fax: Statkraft,Postboks 200 Lilleaker, 0216 Oslo, Norway ABSTRACT

P.O.Box 43 Blindern, 0313 Oslo, Norway Tel.: , Fax: Statkraft,Postboks 200 Lilleaker, 0216 Oslo, Norway ABSTRACT A NEW TESTSITE FOR WIND CORRECTION OF PRECIPITATION MEASUREMENTS AT A MOUNTAIN PLATEAU IN SOUTHERN NORWAY Mareile Wolff 1, Ragnar Brækkan 1, Ketil Isaaksen 1, Erik Ruud 2 1 Norwegian Meteorological Institute,

More information

Breakdown Performance of Vacuum Circuit Breakers Using Alternative CF 3 I-CO 2 Insulation Gas Mixture

Breakdown Performance of Vacuum Circuit Breakers Using Alternative CF 3 I-CO 2 Insulation Gas Mixture 14 P. Widger et al.: Breakdown Performance of Vacuum Circuit Breakers Using Alternative CF 3 I-CO 2 Insulation Gas Mixture Breakdown Performance of Vacuum Circuit Breakers Using Alternative CF 3 I-CO 2

More information

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS

ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS XIX IMEKO World Congress Fundamental and Applied Metrology September 6, 9, Lisbon, Portugal ENVIRONMENTAL AND POLLUTANTS GAS ANALYZERS Ana Madeira, Florbela A. Dias and Eduarda Filipe 3 Instituto Português

More information