FR-6000 Series OUTLINE FEATURES MAIN APPLICATIONS
|
|
- Clementine Hudson
- 5 years ago
- Views:
Transcription
1 PREURE- TIGHT FAMEPROOF FOR HYDROGEN ATMOPHERE READY FR- eries FOAT TYPE EVE WITCH OUTINE FR- is a float-rod type level switch which applies for wide range of pressure and temperature. FR- is suitable for the monitoring of liquid levels in various process tanks, boiler feeding water, etc. FEATURE Wide selection range for temperature and pressure. Variety of material selection for float and chambers for suitable anti-corrosive capability. Perfect isolation between pressurized part and electric component by magnetic coupling for high reliability and safety. In addition to watertight construction, pressure tight and intrinsically safe versions are ready to meet hazardous application. Especially, pressure-tight flameproof suitable for Hydrogen atmosphere (Ex d IIC T) is available which eliminates the necessity of safety barriers. MAIN APPICATION Boiler Feeding drum water control Fuel oil tank level control Process control for petrochemical plants Water treatment plants Oil rig's platform ealing liquid level control for generators and turbines Other liquid level control
2 FR- FOAT TYPE EVE WITCH TANDARD PECIFICATION Detection method : By float Measurement object : iquids (evel) Viscosity : Max. mpa s. iquid without sticking, crystallization, or freezing Density range : For level detection.5 to.g/cm 3 Pressure rating : K (5#), K (3#) Accuracy : ±mm (Density.g/cm 3 ) Repeatability : For level detection ±5mm Reset span : Within 5mm, but more than 5mm, depending on the switch specification and the density. iquid temp. : -5 to + C One cooling fin will be provided for the version for higher temp. than 5 C. Two cooling fins will be provided for the version for higher temp. than 8 C. Contact capacity of such high temp. versions will differ from standard version. Refer to "CONTACT CAPACITY" for further details. Enclosure : Watertight IP5 equ. FR-9 W Pressure-tight flameproof Ex d IIC T FR-9 EX Intrinsically afe Ex ia IIC T FR- 9 (afety relay to be separately installed) Ambient temperature: - C to +8 C, but Flameproof type: - C to +55 C Intrinsically safe ex-proof type: - C to +8 C Installation : Tank top flange connection or Tank side connection through chamber Connection : For tank top installation Through B flange JIK, ANI#5, JPI#5 JIK, ANI#3, JPI#3 or For tank side connection through chamber "W,Rc,"NPT 5AJIKRF, "ANI#5, "JPI#5 5AJIKRF, "ANI#3, "JPI#3 other "flange or others Material : Float / U3, U3, or TP3) ead pipe / U3, U3, or U3 Top flange / Carbon steel, U3, U3, or U3 Housing / Aluminium alloy casting Chamber / Carbon steel U3 / U3 U3 / U3 or U3 / U3 Painting : For liquid temp.upto 5 C Polyurethan resin painting For liquid temp.more than 5 C ilicone resin painting (Only the exterior side of iron and aluminium is painted.) Color : ilver (std.) Alarm point : point (High or ow) Contact : x PDT or PDT (Equ. to DPDT) Contact capacity : Refer to Model code Cable entry : Model Classification Cable entry Remarks FR-9 W (Watertight) G3/ FR-9 EX FR-9 Ex d IIC T Ex ia IIC T G3/ G/ Cable dia. ø9 to G3/ Cable dia. ø to NPT and other threads are available by adapters. Cable termination : By M3.5 screw terminal (M3 screw terminal for high temp. versions) TOKYO KEIO CO., TD. TG-3-3E
3 FR- ERIE FOAT TYPE EVE WITCH MODE CODE Basic code Detection part Chamber FR-9 Pressure rating 5#(K)class 3#(K)class Enclosure W EX Watertight(IP5equ.) Pressure-tight flameproof(ex d IIC T) Intrinsically safe(i3ng5) Top flange size Top flange rating Top flange/ead pipe material Float material JIKRF JPI#5 ANI#5 JIKRF JPI#3 ANI#3 Carbon steel/u3 U3/U3 U3/U3 U3/U3 T "(mm) U3 U3 Titanium witch type, Temp. class etc. C IQUID ON/OFF O CONTACT WITCH WITCH DE TEMP MECHANIM TYPE MODE UPPER ( C) TYPE 5~5 VX-5-A 5~3 V5-A3T PDT 3 3~8 GENERA T-GV 8~ PURPOE OMRON 5 5~5 VX-5-A 5~3 V5-A3T PDT 7 3~8 EARTHQUAKE PROOF T-GV 8 8~ (3G) TYPE A 5~5 B 5~8 PDT M C 8~35 D 5~5 PDT M3A E 5~ HERMETIC (GOD PATED) EA Azbil F 5~5 TYPE G 5~8 PDT M H 8~35 I 5~5 PDT M3A J 5~ (GOD PATED) K 5~5 VX-5-A PDT 5~3 EARTHQUAKE V5-A3T PROOF OMRON M 5~5 (3G) TYPE VX-5-A PDT N 5~3 V5-A3T PECIA CONTACT CAPACITY AC5V, 5A DC5V,.A AC5V, A DC5V,.A AC5V, 5A DC5V,.A AC5V, A DC5V,.A AC5V, 5A DC5V,.3A DC3V, 5A AC5V,.A DC3V,.A AC5V, 5A DC5V,.3A DC3V, 5A AC5V,.A DC3V,.A AC5V, 5A DC5V,.A MINIMUM APPICABE OAD ma ma ma ma ma ma ma ma ma * : For applications with lower temperature than - C, an extension unit will be added and the external dimension will be diferrent from the standard versions. Conslut fectory for details. NO. OF COOING FIN D A B Gasket material VORTEX(U3) VORTEX(U3) Bolts, nuts and gaskets for process connection are to be supplied by the customer. Chamber connection Chamber material Chamber material "W Rc "NPT "JIKRF "JPI#5 "ANI#5 BJIK "JPI#3 "ANI#3 Other "(5mm)flange Carbon steel U3 U3 U3 ide-ide ide-bottom witch action H High alarm ow alarm TG-3-3E TOKYO KEIO CO., TD. 3
4 FR- FOAT TYPE EVE WITCH FOAT TYPE AND DIMENION Float No Table : Float Table Minimum possible density (g/cm 3 ) Maximum possible pressure (MPa) tandard design Purged The content of this table may differ for alam point and switch type. Float design Table : Float dimension Float No. Dimension (mm) - T - 3- T TOKYO KEIO CO., TD. TG-3-3E
5 FR- ERIE FOAT TYPE EVE WITCH EXTERNA DIMENION. Detection part TG-3-3E TOKYO KEIO CO., TD. 5
6 FR- FOAT TYPE EVE WITCH ACTUATING The standard alarm actuating point of FR- level switches is as follows. Other actuating point is available as special order. Please ordering. ) For Top flange installation type TERMINA ARRANGEMENT PDT Terminal No. PDT Terminal No. NC NC NO NO COM COM 3 3 NC M3.5* NO 5 COM * M3 terminal for high temp. version Figures show the switch action at Normal level (witch is not actuated). M3.5* INTRINICAY AFE REAY (EB3C) 35 ) For External chamber installation type Explosion protection Rated operating voltage Rated operating current Installation location Contact configuration Relay output (Resistance load) Contact allowable power (Resistance load) Insulation resistance Withstand voltage Intrinsically safe Ex ia IIC DCV±% DCmA±% Non-hazardous area a contact AC5V, 3A DCV, 3A AC75VA DC7W at MΩ AC5V ( min.) 7 Intrinsically safe relay is to be inserted into the contact loop of F- type level switch. to 3 points use relays are available. elect suitable I relay considering the total number of contacts. tandard pecification Model code Description EB3C- Output type R R Model Relay output No. of contact Power supply 3 A D point use points use 3 points use ACV to V, 5/Hz DCV EB3C Dimensions 7mm below the center line of upper nozzle both for side~side and side~bottom type chambers. EB3C-R EB3C-R, R CAUTION FOR WIRING In case of the flameproof type (FR-9 EX) and intrinsically safe (FR-9 ) to be used in Japan, the cable wiring is to be conducted in accordance with the enforcement regulations of Cable Wiring system in FAMEPROOF TYPE CABE WIRING as specified in Industrial afety and Health aw. For details, refer to UER GUIDEINE for Electrical Installation for Explosive Gas Atmospheres in General Industry edited by MINITRY OF HEATH, ABOR AND WEFARE REEARCH INTITUTE OF IN- DUTRIA AFETY JAPAN. 75 MAX. MIN.ø3 () 5 Applicable crimping terminal FR-9 EX type pressure tight flameproof version is certified for Exd IICT classification under the condition of using our designated pressure-tight cable glands which are delivered together with level switches. They are to be properly installed. MAX.3 MIN.5. Terminal screw size : M3 TOKYO KEIO CO., TD. TG-3-3E
7 FR- ERIE FOAT TYPE EVE WITCH ORDERING PECIFICATION pecify the following for order/inquiry: TAG No. Model Q' TY FR-9 iquid name Density Pressure NOR. Max. MPa ( ) TEMP. NOR. Max. C ( ) ACTUATING TANDARD CUTOM ORDER (pecify length) TANDARD CUTOM ORDER (pecify l length) CHAMBER IE OTHER EVE WITCHE Different types of level switches are available to meet the requirements. Consult factory for further details. FB-5 Ball float type FB-7 Ball float type FP- ead plpe type F- Displacer type IN CAE PREURE TIGHT CABE GAN- D ARE INCUDED: Outer diameter of cable mm For I version (FR-9 ) I relay to be included I relay not included Q'ty point use ( ), 3 points use ( ) Power supply AC/V, AC/V OTHER PECIA INTRUCTION, IF ANY FM- Metal tube magnetic float type * pecification is subject to change without notice. Head Office : hiba Toho Building, 7 hibakoen, Minato-ku, Tokyo 5 58 Tel : (KEY) ; Fax : overseas.sales@tokyokeiso.co.jp ; UR : TG-3-3E TOKYO KEIO CO., TD. 7
C-21 C-22. Gases and liquids ~0.4 5 Rc 1/4 thread 0.9
T MATA CNTANT FW C eries PURGE ET FWMETER WITH CNTANT FW VAVE GENERA C series Constant Flow Valves keep flow rate of gases or liquids even when the supply or load pressure changes. Control valve with diaphragm
More informationALL-IN-ONE MINI THERMAL MASS FLOWMETER
INDICATION, TOTAIZATION, -POINT AARM, DC to ma AND PUSE OUTPUT BY ONE UNIT TF-T Series A-IN-ONE MINI TERMA MASS FOWMETER OUTINE TF-T MINI TERMA MASS FOWMETER is for the measurement of mass flow rate of
More informationC-21 C-22. Gases and liquids ~0.4 ±5 Rc 1/ It is general data, and the maximum temperature may change by terms of use and environment.
TO MATA CONSTANT FOW C Series PURGE SET FOWMETER WITH CONSTANT FOW VAVE GENERA C series Constant Flow Valves keep flow rate of gases or liquids even when the supply or load pressure changes. Control valve
More informationMagnetic level switch type MR783 Instruction Manual
Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2
More informationLevel transmitter LT 100
KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationTC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER GENERAL FEATURES OPERATION PRINCIPLE
FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES TC Series THERMAL MASS FLOW CONTROLLER GENERAL TC series are thermal mass flow controllers, a combination of thermal mass flowmeter and control valve. TC
More informationTC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE
FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES TC Series THERMAL MASS FLOW CONTROLLER OUTLINE TC series are thermal mass flow controllers, a combination of thermal mass flowmeter and control valve. TC
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationTH-1800-T TRX-700-CNG Converter
TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter
More informationTorque Tube TB300 Digital Transmitters
Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationElectro-Pneumatic Converter YT-940 SERIES
Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product
More informationNEW TYPE M PRESSURE RELIEF DEVICE
NEW TYPE M PRESSURE RELIEF DEVICE M PRESSURE RELIEF DEVICE ACCORDING TO EN 50216-5/A2 PATENTED 2 PRESSURE RELIEF DEVICE TYPE 50 M Section A-A 170 139 Transformer tank F 41.5 3 ø48.3 ø166 A P.R.D. TAG A
More informationElectropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765
Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from
More informationTFE-LINED VAREA-METER PVC-TUBE VAREA-METER
TFE-Lined Varea-Meter PVC-Tube Varea-Meter USFilter s Wallace & Tiernan Products offers a choice of two straight-through rotameters for metering difficult fluids and gases. The TFE-lined Varea-Meter is
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationFeatures. Description
Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter
More informationLiquid level instruments BM 24 /BM 51
KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More informationMobrey MLT100 Displacer Level Transmitter
Product Data Sheet Mobrey MLT100 Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting Two-wire 24 Vdc loop-powered 4 20 ma HART output ATEX
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More informationNC MAGNETIC FLOAT SWITCHES FOR LIQUIDS
NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS Flow Pressure Level Temperature measurement monitoring control N Available Materials: Brass, Stainless Steel, Buna-N, Polypropylene and PVC Maximum Pressure: 400
More informationUser s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E
User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at
More informationINSTRUCTION MANUAL. FLOAT TYPE LEVEL TRANSMITTER HT-100R Series HITROL CO., LTD.
HITROL CO., LTD. HEAD OFFICE.FACTORY.R&D INSTITUDE HITROL CO.,LTD 141, Palhakgol-gil, Jori-eup Paju-si, Gyeonggi-do, Korea TEL. : (00)-82-31-950-9700 FAX. : (00)-82-31-943-5600 www.hitrol.com INSTRUCTION
More informationL (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:
Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationOSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide
OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature
More information9700 Transmitter Submersible hydrostatic level transmitter
Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous
More informationLevel switches Series LD Vibrating fork level switch for liquids and solids
Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant
More informationDigital Flow Switch. Series PFM7
Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow
More informationOFFICINE OROBICHE S.p.A. 1/9
OFFICINE OROBICHE S.p.A. 1/9 INSTRUCTIONS MANUAL FOR LEVEL SWITCHES SERIES 7000 mod. 7250 AND 7400 Electric 1. INSTRUMENT DESCRIPTION Series 7000 level switches have been designed for external lateral
More informationFlow Sensors & Hydrometers Specification Sheet
Baseline Flow s and Hydrometers Baseline s smart flow sensors and hydrometers are two-wire ready flow measurement and control devices that are pre-programmed with the correct K and Offset values. In addition,
More informationHow to Order. Finger material. Carbon steel 1 Stainless steel. Dust cover material Chloroprene rubber (CR) Fluoro rubber (FKM) Silicon rubber (Si)
Wedge Cam Operation lide Guide Air Gripper (2 inger) ø2, ø, ø2, ø2 How to Order tandard model 2 2 D N ong stroke model 2 2 D N Number of fingers 2 2 fingers Number of auto switches _ 2 D C 2 2 2 Bore size
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More informationMAGNETIC FLOAT SENSOR
TS02-0143 I N S T R U C T I O N M A N U A L F O R MAGNETIC FLOAT SENSOR MODEL:FR Revision 2015-04-17 Read and understand this manual for safely usage. This manual describes the product of standard specification.
More informationKF Series Liquid Level Indicating Controller
KF Series Liquid Level Indicating Controller OVERVIEW The KF Series instruments are field-mounted type pneumatic indicating controllers which are used to measure and control various types of process variables
More informationMiniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800
KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential
More informationInstallation and Operation Manual
Installation and Operation Manual WIKA FLR-SBDF / BLR-SBDF Magnetic Level Transmitter (Please retain for future usage) Contact: Gayesco-WIKA USA, L.P. 229 Beltway Green Boulevard Pasadena, TX 77503 www.wika.com
More information4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.
qwer Air and Inert Gas Valves Brass, or Stainless Steel Bodies 1/" to 1" NPT Features Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting
More informationMobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters
Product Data Sheet Mobrey 9700 Transmitter Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters Hydrostatic electronic level transmitters Factory sealed and tested for submersed duty 4 20
More informationMechanical Pressure Switches for overpressure, vacuum pressure and differential pressure
Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure Switching range: -250 +100 mbar, 1 16 mbar to 16 63 bar Temperature: max. 70 C Material: Copper, brass, stainless
More informationTechnical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications
Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or
More informationMLS Series Liquid Level Switches. Installation and Operations Manual Section 15
MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2012-11-11 Section 15 In order to consistently bring you the highest quality full featured products, we reserve the right
More informationZ, Y, and X PURGE INDICATORS / CONTROLLERS
PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories
More informationSSL. Smart Valve Positioner.
Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationIntrinsically safe solenoid valves on/off controls - ATEX certification
www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6
More informationAuto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9
Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance
More informationGAS FUEL VALVE FORM AGV5 OM 8-03
ALTRONIC AGV5 OPERATING MANUAL GAS FUEL VALVE FORM AGV5 OM 8-03 WARNING: DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE PERSONAL INJURY TO OPERATORS
More informationE2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information
Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.
More informationISO 9001/ Model SDT-420. Torque Tube, Displacement Type Level Transmitter
ISO 9001/14001 Model SDT-420 Torque Tube, Displacement Type Level Transmitter SDT-420 Introduction The SEOJIN INSTECH model SDT-420 Displacement Level Transmitter is one of the most advanced level instruments
More informationVERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.
SUMP PUMP PIT UNIT FEATURES All needed parts are assembled and united as a sump pit and easy to install for short period. Sump tank is made of SUS with epoxy coating and pipe is integrated by stainless
More informationOperating Instructions
LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.
More informationCompact Pressure Switch
Compact Pressure Switch Series 2 (For Vacuum)/ 2 (For Positive Pressure) For General Pneumatics Can be integrated with ZX or ZR ejector system. A Easy and simple wiring Connector type 77 Compact Pressure
More informationVG5 Supplementary instructions
VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...
More informationTECHNICAL DATA. Q = C v P S
Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction
More informationGeneral Specifications
General Specifications DOG Optical Dissolved Oxygen Sensor GENERA DOG optical dissolved oxygen sensor is designed for using in water treatment plants such as sewage treatment works and effl uent activated
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated
More informationModel 4000 Pressure Controller
FEATURES Multiple Configurations The 4000 series pressure controller can be configured into either proportional only or proportional plus reset mode with a minimum of parts. Rugged Design Die cast aluminum
More informationTF- & DM-Series. Turbineflowmeter
Turbineflowmeter .. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation
More informationPressure Switches Application Guideline
Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment
More informationTightness controls TC 1 3 and TC 4
Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems
More informationProduct information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983
Product information Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69 Document ID: 29983 Contents Contents 1 Description of the measuring principle... 3 2 Type overview...
More informationVortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres
Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Drawing 1 VA Di ZG1 Ex-d Measured variables actual flow rate
More informationEx-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC
www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive
More informationMOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL
MOYNO Section: ACCESSORIES Page: 1 of 8 Date: May 1, 1998 SERVICE MANUAL FLUID DETECTION CONTROL GENERAL The Moyno Fluid Detection Control prevents unnecessary loss of production time or repair costs to
More informationVA40 - VA45 Technical Datasheet
VA40 - VA45 Technical Datasheet Variable area flowmeter Local indication without auxiliary power Adaptable to meet customers' requirements Replaceable mounting parts KROHNE CONTENTS VA40 - VA45 1 Product
More informationWafer type. the product
. VFM5 Vortex Flow Meter Flanged type Wafer type Insertion type VFM5 is a powerful flow meter utilizing Karman vortex theory, which can meet the requirement of measuring the flow rate of various fluids
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
More informationE10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.
> Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to
More informationLiquid Level Indicating Controller
OVERVIEW KF Series Liquid Level Indicating Controller The KF Series instruments are field-mounted type pnematic indicating controllers which are used to measure and control various types of process variables
More informationSSR. Smart Valve Positioner.
Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration
More informationTwo-Wire In Situ Oxygen Analyzer (550 to 1400 C)
Product Data Sheet PDS 106-581.A01 September, 2007 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: ATEX, Zone 1, EEx ia IIC T4 Class I, Div. I, Gr. A, B, C, D T4 Operates
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS
03304 Float Gauge: Level measurement Application: LNG tanks Level 03304 E 1 ADVANTAGES - High level accuracy - Local mechanical counter read out. - High reliability - Suitable for 12 and 8 still well.
More informationPressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview
f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection
More informationKDV HIGH ACCURACY GLASS TUBE ROTAMETER
KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design
More informationPressure transmitter PASCAL Ci4
Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationThe Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal
More informationNC MAGNETIC FLOAT SWITCHES FOR LIQUIDS
NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS Flow Pressure Level Temperature measurement monitoring control N1 Available Materials: Brass, Stainless Steel, Buna-N, Polypropylene and PVC Maximum Pressure: 400
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationIntegral type Differential pressure flowmeter VNT Series
Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.
More informationHidrostatic Level DATASHEET
Hidrostatic Level DATASHEET JUNHO 2013 Hydrostatic level probes SGE-25 and SGE-16 SG cable hanger Red (+) Capillary Black ( ) PP junction box Any measurement range from 1 up to 500 m H 2 O Integrated internal
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationSafety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions
More informationGA24 Technical Datasheet
GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features
More informationPressure & Temperature Switches
Pressure & Temperature Switches The User Friendly Generation General Bulletin TEMPERATURE SWITCHES BETA TEMPERATURE SWITCH The BETA Temperature Switch is a pressure switch incorporating a sealed 2-phase
More informationElectronic Turbine Meter TERZ 94
Electronic Turbine Meter TERZ 9 PRODUT INFORMTION Reliable Measurements of Gas EETRONI TURINE METER TERZ 9 Methode of operation, construction 2 Methode of operation The TERZ 9 electronic turbine meter
More information10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor
2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/EA ZSE E RoHS New IP65 ZSE E ZSE0 E0 M8 connector type E70 ZSE E E Applicable Air, Non-corrosive gas, Non-flammable gas fluid Can copy
More informationExcellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA
Excellent Vortex meter INSERTION Type BATTERY POWERED EX DELTA GENERAL SPECIFICATION GS.No.GBD604E-6 GENERAL The battery-powered EX DELTA is a dedicated on site monitor with a wide variety of applications
More informationTECHNICAL DATA OBSOLETE
April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,
More informationGlass tube flowmeters Series 2000
Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No
More informationRosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch
Technical Note ommunicate Rosemount 2130 Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch The Rosemount 2130 Vibrating Fork Level Switch, based on vibrating short fork technology,
More informationRTD Temperature sensor TH11
RTD Temperature sensor TH11 Compact Instructions Measuring System General purpose RTD with connection head TH11 for process and laboratory applications. The single element RTD is specifi cally designed
More informationUltrasonic level transmitter and indicator
Ultrasonic level transmitter and indicator No contact with the product Compact design with polycarbonate housing (electronics and display). Remote display available on request Very good resistance in corrosive
More informationKDV HIGH ACCURACY GLASS TUBE ROTAMETER
KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design
More information