FR-6000 Series OUTLINE FEATURES MAIN APPLICATIONS

Size: px
Start display at page:

Download "FR-6000 Series OUTLINE FEATURES MAIN APPLICATIONS"

Transcription

1 PREURE- TIGHT FAMEPROOF FOR HYDROGEN ATMOPHERE READY FR- eries FOAT TYPE EVE WITCH OUTINE FR- is a float-rod type level switch which applies for wide range of pressure and temperature. FR- is suitable for the monitoring of liquid levels in various process tanks, boiler feeding water, etc. FEATURE Wide selection range for temperature and pressure. Variety of material selection for float and chambers for suitable anti-corrosive capability. Perfect isolation between pressurized part and electric component by magnetic coupling for high reliability and safety. In addition to watertight construction, pressure tight and intrinsically safe versions are ready to meet hazardous application. Especially, pressure-tight flameproof suitable for Hydrogen atmosphere (Ex d IIC T) is available which eliminates the necessity of safety barriers. MAIN APPICATION Boiler Feeding drum water control Fuel oil tank level control Process control for petrochemical plants Water treatment plants Oil rig's platform ealing liquid level control for generators and turbines Other liquid level control

2 FR- FOAT TYPE EVE WITCH TANDARD PECIFICATION Detection method : By float Measurement object : iquids (evel) Viscosity : Max. mpa s. iquid without sticking, crystallization, or freezing Density range : For level detection.5 to.g/cm 3 Pressure rating : K (5#), K (3#) Accuracy : ±mm (Density.g/cm 3 ) Repeatability : For level detection ±5mm Reset span : Within 5mm, but more than 5mm, depending on the switch specification and the density. iquid temp. : -5 to + C One cooling fin will be provided for the version for higher temp. than 5 C. Two cooling fins will be provided for the version for higher temp. than 8 C. Contact capacity of such high temp. versions will differ from standard version. Refer to "CONTACT CAPACITY" for further details. Enclosure : Watertight IP5 equ. FR-9 W Pressure-tight flameproof Ex d IIC T FR-9 EX Intrinsically afe Ex ia IIC T FR- 9 (afety relay to be separately installed) Ambient temperature: - C to +8 C, but Flameproof type: - C to +55 C Intrinsically safe ex-proof type: - C to +8 C Installation : Tank top flange connection or Tank side connection through chamber Connection : For tank top installation Through B flange JIK, ANI#5, JPI#5 JIK, ANI#3, JPI#3 or For tank side connection through chamber "W,Rc,"NPT 5AJIKRF, "ANI#5, "JPI#5 5AJIKRF, "ANI#3, "JPI#3 other "flange or others Material : Float / U3, U3, or TP3) ead pipe / U3, U3, or U3 Top flange / Carbon steel, U3, U3, or U3 Housing / Aluminium alloy casting Chamber / Carbon steel U3 / U3 U3 / U3 or U3 / U3 Painting : For liquid temp.upto 5 C Polyurethan resin painting For liquid temp.more than 5 C ilicone resin painting (Only the exterior side of iron and aluminium is painted.) Color : ilver (std.) Alarm point : point (High or ow) Contact : x PDT or PDT (Equ. to DPDT) Contact capacity : Refer to Model code Cable entry : Model Classification Cable entry Remarks FR-9 W (Watertight) G3/ FR-9 EX FR-9 Ex d IIC T Ex ia IIC T G3/ G/ Cable dia. ø9 to G3/ Cable dia. ø to NPT and other threads are available by adapters. Cable termination : By M3.5 screw terminal (M3 screw terminal for high temp. versions) TOKYO KEIO CO., TD. TG-3-3E

3 FR- ERIE FOAT TYPE EVE WITCH MODE CODE Basic code Detection part Chamber FR-9 Pressure rating 5#(K)class 3#(K)class Enclosure W EX Watertight(IP5equ.) Pressure-tight flameproof(ex d IIC T) Intrinsically safe(i3ng5) Top flange size Top flange rating Top flange/ead pipe material Float material JIKRF JPI#5 ANI#5 JIKRF JPI#3 ANI#3 Carbon steel/u3 U3/U3 U3/U3 U3/U3 T "(mm) U3 U3 Titanium witch type, Temp. class etc. C IQUID ON/OFF O CONTACT WITCH WITCH DE TEMP MECHANIM TYPE MODE UPPER ( C) TYPE 5~5 VX-5-A 5~3 V5-A3T PDT 3 3~8 GENERA T-GV 8~ PURPOE OMRON 5 5~5 VX-5-A 5~3 V5-A3T PDT 7 3~8 EARTHQUAKE PROOF T-GV 8 8~ (3G) TYPE A 5~5 B 5~8 PDT M C 8~35 D 5~5 PDT M3A E 5~ HERMETIC (GOD PATED) EA Azbil F 5~5 TYPE G 5~8 PDT M H 8~35 I 5~5 PDT M3A J 5~ (GOD PATED) K 5~5 VX-5-A PDT 5~3 EARTHQUAKE V5-A3T PROOF OMRON M 5~5 (3G) TYPE VX-5-A PDT N 5~3 V5-A3T PECIA CONTACT CAPACITY AC5V, 5A DC5V,.A AC5V, A DC5V,.A AC5V, 5A DC5V,.A AC5V, A DC5V,.A AC5V, 5A DC5V,.3A DC3V, 5A AC5V,.A DC3V,.A AC5V, 5A DC5V,.3A DC3V, 5A AC5V,.A DC3V,.A AC5V, 5A DC5V,.A MINIMUM APPICABE OAD ma ma ma ma ma ma ma ma ma * : For applications with lower temperature than - C, an extension unit will be added and the external dimension will be diferrent from the standard versions. Conslut fectory for details. NO. OF COOING FIN D A B Gasket material VORTEX(U3) VORTEX(U3) Bolts, nuts and gaskets for process connection are to be supplied by the customer. Chamber connection Chamber material Chamber material "W Rc "NPT "JIKRF "JPI#5 "ANI#5 BJIK "JPI#3 "ANI#3 Other "(5mm)flange Carbon steel U3 U3 U3 ide-ide ide-bottom witch action H High alarm ow alarm TG-3-3E TOKYO KEIO CO., TD. 3

4 FR- FOAT TYPE EVE WITCH FOAT TYPE AND DIMENION Float No Table : Float Table Minimum possible density (g/cm 3 ) Maximum possible pressure (MPa) tandard design Purged The content of this table may differ for alam point and switch type. Float design Table : Float dimension Float No. Dimension (mm) - T - 3- T TOKYO KEIO CO., TD. TG-3-3E

5 FR- ERIE FOAT TYPE EVE WITCH EXTERNA DIMENION. Detection part TG-3-3E TOKYO KEIO CO., TD. 5

6 FR- FOAT TYPE EVE WITCH ACTUATING The standard alarm actuating point of FR- level switches is as follows. Other actuating point is available as special order. Please ordering. ) For Top flange installation type TERMINA ARRANGEMENT PDT Terminal No. PDT Terminal No. NC NC NO NO COM COM 3 3 NC M3.5* NO 5 COM * M3 terminal for high temp. version Figures show the switch action at Normal level (witch is not actuated). M3.5* INTRINICAY AFE REAY (EB3C) 35 ) For External chamber installation type Explosion protection Rated operating voltage Rated operating current Installation location Contact configuration Relay output (Resistance load) Contact allowable power (Resistance load) Insulation resistance Withstand voltage Intrinsically safe Ex ia IIC DCV±% DCmA±% Non-hazardous area a contact AC5V, 3A DCV, 3A AC75VA DC7W at MΩ AC5V ( min.) 7 Intrinsically safe relay is to be inserted into the contact loop of F- type level switch. to 3 points use relays are available. elect suitable I relay considering the total number of contacts. tandard pecification Model code Description EB3C- Output type R R Model Relay output No. of contact Power supply 3 A D point use points use 3 points use ACV to V, 5/Hz DCV EB3C Dimensions 7mm below the center line of upper nozzle both for side~side and side~bottom type chambers. EB3C-R EB3C-R, R CAUTION FOR WIRING In case of the flameproof type (FR-9 EX) and intrinsically safe (FR-9 ) to be used in Japan, the cable wiring is to be conducted in accordance with the enforcement regulations of Cable Wiring system in FAMEPROOF TYPE CABE WIRING as specified in Industrial afety and Health aw. For details, refer to UER GUIDEINE for Electrical Installation for Explosive Gas Atmospheres in General Industry edited by MINITRY OF HEATH, ABOR AND WEFARE REEARCH INTITUTE OF IN- DUTRIA AFETY JAPAN. 75 MAX. MIN.ø3 () 5 Applicable crimping terminal FR-9 EX type pressure tight flameproof version is certified for Exd IICT classification under the condition of using our designated pressure-tight cable glands which are delivered together with level switches. They are to be properly installed. MAX.3 MIN.5. Terminal screw size : M3 TOKYO KEIO CO., TD. TG-3-3E

7 FR- ERIE FOAT TYPE EVE WITCH ORDERING PECIFICATION pecify the following for order/inquiry: TAG No. Model Q' TY FR-9 iquid name Density Pressure NOR. Max. MPa ( ) TEMP. NOR. Max. C ( ) ACTUATING TANDARD CUTOM ORDER (pecify length) TANDARD CUTOM ORDER (pecify l length) CHAMBER IE OTHER EVE WITCHE Different types of level switches are available to meet the requirements. Consult factory for further details. FB-5 Ball float type FB-7 Ball float type FP- ead plpe type F- Displacer type IN CAE PREURE TIGHT CABE GAN- D ARE INCUDED: Outer diameter of cable mm For I version (FR-9 ) I relay to be included I relay not included Q'ty point use ( ), 3 points use ( ) Power supply AC/V, AC/V OTHER PECIA INTRUCTION, IF ANY FM- Metal tube magnetic float type * pecification is subject to change without notice. Head Office : hiba Toho Building, 7 hibakoen, Minato-ku, Tokyo 5 58 Tel : (KEY) ; Fax : overseas.sales@tokyokeiso.co.jp ; UR : TG-3-3E TOKYO KEIO CO., TD. 7

C-21 C-22. Gases and liquids ~0.4 5 Rc 1/4 thread 0.9

C-21 C-22. Gases and liquids ~0.4 5 Rc 1/4 thread 0.9 T MATA CNTANT FW C eries PURGE ET FWMETER WITH CNTANT FW VAVE GENERA C series Constant Flow Valves keep flow rate of gases or liquids even when the supply or load pressure changes. Control valve with diaphragm

More information

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

ALL-IN-ONE MINI THERMAL MASS FLOWMETER INDICATION, TOTAIZATION, -POINT AARM, DC to ma AND PUSE OUTPUT BY ONE UNIT TF-T Series A-IN-ONE MINI TERMA MASS FOWMETER OUTINE TF-T MINI TERMA MASS FOWMETER is for the measurement of mass flow rate of

More information

C-21 C-22. Gases and liquids ~0.4 ±5 Rc 1/ It is general data, and the maximum temperature may change by terms of use and environment.

C-21 C-22. Gases and liquids ~0.4 ±5 Rc 1/ It is general data, and the maximum temperature may change by terms of use and environment. TO MATA CONSTANT FOW C Series PURGE SET FOWMETER WITH CONSTANT FOW VAVE GENERA C series Constant Flow Valves keep flow rate of gases or liquids even when the supply or load pressure changes. Control valve

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER GENERAL FEATURES OPERATION PRINCIPLE

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER GENERAL FEATURES OPERATION PRINCIPLE FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES TC Series THERMAL MASS FLOW CONTROLLER GENERAL TC series are thermal mass flow controllers, a combination of thermal mass flowmeter and control valve. TC

More information

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES TC Series THERMAL MASS FLOW CONTROLLER OUTLINE TC series are thermal mass flow controllers, a combination of thermal mass flowmeter and control valve. TC

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

TH-1800-T TRX-700-CNG Converter

TH-1800-T TRX-700-CNG Converter TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter

More information

Torque Tube TB300 Digital Transmitters

Torque Tube TB300 Digital Transmitters Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

Electro-Pneumatic Converter YT-940 SERIES

Electro-Pneumatic Converter YT-940 SERIES Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product

More information

NEW TYPE M PRESSURE RELIEF DEVICE

NEW TYPE M PRESSURE RELIEF DEVICE NEW TYPE M PRESSURE RELIEF DEVICE M PRESSURE RELIEF DEVICE ACCORDING TO EN 50216-5/A2 PATENTED 2 PRESSURE RELIEF DEVICE TYPE 50 M Section A-A 170 139 Transformer tank F 41.5 3 ø48.3 ø166 A P.R.D. TAG A

More information

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765 Application Single-acting positioner for attachment to pneumatic control valves. Supplied with either an electric input signal from

More information

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER

TFE-LINED VAREA-METER PVC-TUBE VAREA-METER TFE-Lined Varea-Meter PVC-Tube Varea-Meter USFilter s Wallace & Tiernan Products offers a choice of two straight-through rotameters for metering difficult fluids and gases. The TFE-lined Varea-Meter is

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

Features. Description

Features. Description Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter

More information

Liquid level instruments BM 24 /BM 51

Liquid level instruments BM 24 /BM 51 KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Monitoring device NTS 30

Monitoring device NTS 30 P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit

More information

Mobrey MLT100 Displacer Level Transmitter

Mobrey MLT100 Displacer Level Transmitter Product Data Sheet Mobrey MLT100 Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting Two-wire 24 Vdc loop-powered 4 20 ma HART output ATEX

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS Flow Pressure Level Temperature measurement monitoring control N Available Materials: Brass, Stainless Steel, Buna-N, Polypropylene and PVC Maximum Pressure: 400

More information

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 March, 2004 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: - CENELEC EEx ia IIC - Class I Div. I Gr. B, C, D (pending) Operates at

More information

INSTRUCTION MANUAL. FLOAT TYPE LEVEL TRANSMITTER HT-100R Series HITROL CO., LTD.

INSTRUCTION MANUAL. FLOAT TYPE LEVEL TRANSMITTER HT-100R Series HITROL CO., LTD. HITROL CO., LTD. HEAD OFFICE.FACTORY.R&D INSTITUDE HITROL CO.,LTD 141, Palhakgol-gil, Jori-eup Paju-si, Gyeonggi-do, Korea TEL. : (00)-82-31-950-9700 FAX. : (00)-82-31-943-5600 www.hitrol.com INSTRUCTION

More information

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.: Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

Digital Flow Switch. Series PFM7

Digital Flow Switch. Series PFM7 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow

More information

OFFICINE OROBICHE S.p.A. 1/9

OFFICINE OROBICHE S.p.A. 1/9 OFFICINE OROBICHE S.p.A. 1/9 INSTRUCTIONS MANUAL FOR LEVEL SWITCHES SERIES 7000 mod. 7250 AND 7400 Electric 1. INSTRUMENT DESCRIPTION Series 7000 level switches have been designed for external lateral

More information

Flow Sensors & Hydrometers Specification Sheet

Flow Sensors & Hydrometers Specification Sheet Baseline Flow s and Hydrometers Baseline s smart flow sensors and hydrometers are two-wire ready flow measurement and control devices that are pre-programmed with the correct K and Offset values. In addition,

More information

How to Order. Finger material. Carbon steel 1 Stainless steel. Dust cover material Chloroprene rubber (CR) Fluoro rubber (FKM) Silicon rubber (Si)

How to Order. Finger material. Carbon steel 1 Stainless steel. Dust cover material Chloroprene rubber (CR) Fluoro rubber (FKM) Silicon rubber (Si) Wedge Cam Operation lide Guide Air Gripper (2 inger) ø2, ø, ø2, ø2 How to Order tandard model 2 2 D N ong stroke model 2 2 D N Number of fingers 2 2 fingers Number of auto switches _ 2 D C 2 2 2 Bore size

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

MAGNETIC FLOAT SENSOR

MAGNETIC FLOAT SENSOR TS02-0143 I N S T R U C T I O N M A N U A L F O R MAGNETIC FLOAT SENSOR MODEL:FR Revision 2015-04-17 Read and understand this manual for safely usage. This manual describes the product of standard specification.

More information

KF Series Liquid Level Indicating Controller

KF Series Liquid Level Indicating Controller KF Series Liquid Level Indicating Controller OVERVIEW The KF Series instruments are field-mounted type pneumatic indicating controllers which are used to measure and control various types of process variables

More information

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800 KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual WIKA FLR-SBDF / BLR-SBDF Magnetic Level Transmitter (Please retain for future usage) Contact: Gayesco-WIKA USA, L.P. 229 Beltway Green Boulevard Pasadena, TX 77503 www.wika.com

More information

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4 to 1 NPT SERIES. qwer Air and Inert Gas Valves Brass, or Stainless Steel Bodies 1/" to 1" NPT Features Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting

More information

Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters

Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters Product Data Sheet Mobrey 9700 Transmitter Mobrey 9700 Transmitter Submersible Hydrostatic Level Transmitters Hydrostatic electronic level transmitters Factory sealed and tested for submersed duty 4 20

More information

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure

Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure Mechanical Pressure Switches for overpressure, vacuum pressure and differential pressure Switching range: -250 +100 mbar, 1 16 mbar to 16 63 bar Temperature: max. 70 C Material: Copper, brass, stainless

More information

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or

More information

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15 MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2012-11-11 Section 15 In order to consistently bring you the highest quality full featured products, we reserve the right

More information

Z, Y, and X PURGE INDICATORS / CONTROLLERS

Z, Y, and X PURGE INDICATORS / CONTROLLERS PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories

More information

SSL. Smart Valve Positioner.

SSL. Smart Valve Positioner. Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

GAS FUEL VALVE FORM AGV5 OM 8-03

GAS FUEL VALVE FORM AGV5 OM 8-03 ALTRONIC AGV5 OPERATING MANUAL GAS FUEL VALVE FORM AGV5 OM 8-03 WARNING: DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE PERSONAL INJURY TO OPERATORS

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

ISO 9001/ Model SDT-420. Torque Tube, Displacement Type Level Transmitter

ISO 9001/ Model SDT-420. Torque Tube, Displacement Type Level Transmitter ISO 9001/14001 Model SDT-420 Torque Tube, Displacement Type Level Transmitter SDT-420 Introduction The SEOJIN INSTECH model SDT-420 Displacement Level Transmitter is one of the most advanced level instruments

More information

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD. SUMP PUMP PIT UNIT FEATURES All needed parts are assembled and united as a sump pit and easy to install for short period. Sump tank is made of SUS with epoxy coating and pipe is integrated by stainless

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

Compact Pressure Switch

Compact Pressure Switch Compact Pressure Switch Series 2 (For Vacuum)/ 2 (For Positive Pressure) For General Pneumatics Can be integrated with ZX or ZR ejector system. A Easy and simple wiring Connector type 77 Compact Pressure

More information

VG5 Supplementary instructions

VG5 Supplementary instructions VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

General Specifications

General Specifications General Specifications DOG Optical Dissolved Oxygen Sensor GENERA DOG optical dissolved oxygen sensor is designed for using in water treatment plants such as sewage treatment works and effl uent activated

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

Model 4000 Pressure Controller

Model 4000 Pressure Controller FEATURES Multiple Configurations The 4000 series pressure controller can be configured into either proportional only or proportional plus reset mode with a minimum of parts. Rugged Design Die cast aluminum

More information

TF- & DM-Series. Turbineflowmeter

TF- & DM-Series. Turbineflowmeter Turbineflowmeter .. are the ideal solution for measuring applications in liquids when high accuracy, very fast response times, compact design, high reliability are also required in continuous operation

More information

Pressure Switches Application Guideline

Pressure Switches Application Guideline Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment

More information

Tightness controls TC 1 3 and TC 4

Tightness controls TC 1 3 and TC 4 Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems

More information

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983 Product information Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69 Document ID: 29983 Contents Contents 1 Description of the measuring principle... 3 2 Type overview...

More information

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres Drawing 1 VA Di ZG1 Ex-d Measured variables actual flow rate

More information

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive

More information

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL MOYNO Section: ACCESSORIES Page: 1 of 8 Date: May 1, 1998 SERVICE MANUAL FLUID DETECTION CONTROL GENERAL The Moyno Fluid Detection Control prevents unnecessary loss of production time or repair costs to

More information

VA40 - VA45 Technical Datasheet

VA40 - VA45 Technical Datasheet VA40 - VA45 Technical Datasheet Variable area flowmeter Local indication without auxiliary power Adaptable to meet customers' requirements Replaceable mounting parts KROHNE CONTENTS VA40 - VA45 1 Product

More information

Wafer type. the product

Wafer type. the product . VFM5 Vortex Flow Meter Flanged type Wafer type Insertion type VFM5 is a powerful flow meter utilizing Karman vortex theory, which can meet the requirement of measuring the flow rate of various fluids

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1. > Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to

More information

Liquid Level Indicating Controller

Liquid Level Indicating Controller OVERVIEW KF Series Liquid Level Indicating Controller The KF Series instruments are field-mounted type pnematic indicating controllers which are used to measure and control various types of process variables

More information

SSR. Smart Valve Positioner.

SSR. Smart Valve Positioner. Smart Valve Positioner Smartest valve control device meeting a dynamic performance and a precise setting with a piezoelectric technology and an optimized auto-calibration program Features Auto-Calibration

More information

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C)

Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Product Data Sheet PDS 106-581.A01 September, 2007 Model 5081FG Two-Wire In Situ Oxygen Analyzer (550 to 1400 C) Intrinsically safe: ATEX, Zone 1, EEx ia IIC T4 Class I, Div. I, Gr. A, B, C, D T4 Operates

More information

Booster Regulator/Air Tank

Booster Regulator/Air Tank Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed

More information

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS

ADVANTAGES DESCRIPTION MECHANICAL FITTINGS AND DIMENSIONS 03304 Float Gauge: Level measurement Application: LNG tanks Level 03304 E 1 ADVANTAGES - High level accuracy - Local mechanical counter read out. - High reliability - Suitable for 12 and 8 still well.

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

KDV HIGH ACCURACY GLASS TUBE ROTAMETER KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design

More information

Pressure transmitter PASCAL Ci4

Pressure transmitter PASCAL Ci4 Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal

More information

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS

NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS NC MAGNETIC FLOAT SWITCHES FOR LIQUIDS Flow Pressure Level Temperature measurement monitoring control N1 Available Materials: Brass, Stainless Steel, Buna-N, Polypropylene and PVC Maximum Pressure: 400

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Integral type Differential pressure flowmeter VNT Series

Integral type Differential pressure flowmeter VNT Series Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.

More information

Hidrostatic Level DATASHEET

Hidrostatic Level DATASHEET Hidrostatic Level DATASHEET JUNHO 2013 Hydrostatic level probes SGE-25 and SGE-16 SG cable hanger Red (+) Capillary Black ( ) PP junction box Any measurement range from 1 up to 500 m H 2 O Integrated internal

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

Pressure & Temperature Switches

Pressure & Temperature Switches Pressure & Temperature Switches The User Friendly Generation General Bulletin TEMPERATURE SWITCHES BETA TEMPERATURE SWITCH The BETA Temperature Switch is a pressure switch incorporating a sealed 2-phase

More information

Electronic Turbine Meter TERZ 94

Electronic Turbine Meter TERZ 94 Electronic Turbine Meter TERZ 9 PRODUT INFORMTION Reliable Measurements of Gas EETRONI TURINE METER TERZ 9 Methode of operation, construction 2 Methode of operation The TERZ 9 electronic turbine meter

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/EA ZSE E RoHS New IP65 ZSE E ZSE0 E0 M8 connector type E70 ZSE E E Applicable Air, Non-corrosive gas, Non-flammable gas fluid Can copy

More information

Excellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA

Excellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA Excellent Vortex meter INSERTION Type BATTERY POWERED EX DELTA GENERAL SPECIFICATION GS.No.GBD604E-6 GENERAL The battery-powered EX DELTA is a dedicated on site monitor with a wide variety of applications

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,

More information

Glass tube flowmeters Series 2000

Glass tube flowmeters Series 2000 Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No

More information

Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch

Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch Technical Note ommunicate Rosemount 2130 Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch The Rosemount 2130 Vibrating Fork Level Switch, based on vibrating short fork technology,

More information

RTD Temperature sensor TH11

RTD Temperature sensor TH11 RTD Temperature sensor TH11 Compact Instructions Measuring System General purpose RTD with connection head TH11 for process and laboratory applications. The single element RTD is specifi cally designed

More information

Ultrasonic level transmitter and indicator

Ultrasonic level transmitter and indicator Ultrasonic level transmitter and indicator No contact with the product Compact design with polycarbonate housing (electronics and display). Remote display available on request Very good resistance in corrosive

More information

KDV HIGH ACCURACY GLASS TUBE ROTAMETER

KDV HIGH ACCURACY GLASS TUBE ROTAMETER KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design

More information