C-21 C-22. Gases and liquids ~0.4 5 Rc 1/4 thread 0.9

Size: px
Start display at page:

Download "C-21 C-22. Gases and liquids ~0.4 5 Rc 1/4 thread 0.9"

Transcription

1 T MATA CNTANT FW C eries PURGE ET FWMETER WITH CNTANT FW VAVE GENERA C series Constant Flow Valves keep flow rate of gases or liquids even when the supply or load pressure changes. Control valve with diaphragm automatically acts following the change of pressure. They are normally delivered together with flowmeter as a "Purge set". Primary(Inlet) pressure variation control type and econdary(utlet) pressure variation control type are ready to meet all possible applications. EUP Type Applicable Fluid Max.Process Press (MPa) Max.Process Temp ( C) Controllable Dp range (MPa) Control Accuracy (%,F..) Process connection Approx. MA (kg) C- P(ET) Variation C- P(ET) Variation Gases only C- 0.03~0.3 C- 0.05~0.3 3 Rc /8 thread 0. C- P(ET) Variation C- P(ET) Variation Gases and liquids ~0. 5 Rc / thread 0.9 C-3 P(ET) Variation C-3 P(ET) Variation Gases and liquids ~0.5 5 Rc 3/8 thread.3 C- P(ET) Variation C- P(ET) Variation Gases and liquids ~0.6 5 Rc / thread 8.0 PERATIN PRCIPE In the PRIMARY (ET) PREURE VARIATIN CNTR TYPE, the fluid, of which inlet pressure varies, is introduced from to the lower chamber of the C series Constant Flow Valve. The load pressure (econdary pressure) is connected to the upper chamber. The differential pressure between the lower chamber and the upper chamber is always constant thanks to the function of the pring and the Diaphragm. The differential pressure across the needle valve is kept always constant and the flow rate of the fluid is proportional only to the opening of needle valve. The opposite action is taken for ECNDARY (ET) PREURE VARIATIN CNTR TYPE and the flow rate is kept also constant even when the load pressure changes. Upper chamber pring Upper chamber Diaphragm Diaphragm pring ower chamber Control Valve part ower chamber Control Valve part utlet (Pressure constant) Needle valve Inlet (Press. variation) Inlet (Pressure constant) Needle valve utlet (Press. variation) PRIMARY (ET) PREURE VARIATIN CNTR TYPE (C-M) ECNDARY (ET) PREURE VARIATIN CNTR TYPE (C-M) TG-F76-E TG-F76-6E JUN. 5K MAY. 03K

2 C eries PURGE ET APPICATIN UPPY PREURE VARIATIN EVE MEAUREMENT P Pressure Gauge/DP Transmitter Main valve Gus supply Branch valve Purge set H Purge set Air supply As shown above, in case one large supply line branches into several lines and the supply pressure changes because of stoppage of some branches. Primary Pressure Variation type Purge set will be suitable in keeping the purging volume of fluid. iquid level in tanks is measured by the Back-pressure at the edge of purging pipe. The outlet pressure at the tank bottom changes depending on the liquid level, and constant bubbling is required. Thus, econdary Pressure Variation type purge set is used for this application. A DP transmitter is often connected to pressure line instead of pressure gauge for remote transmission. Recommended Model of Purgeset: CP-M-MMM Recommended Model of Purgeset: P CP-M-MMM, CP--00-B H = PURGG FR RIFICE PATE APPICATIN DENITY MEAUREMENT rifice plate P P DP Transmitter DP Gauge/ DP Transmitter Purge set H H Purge set Refarence tank Air supply Air supply For the measurement of flow rate of corrosive liquids and/or liquids with solids by orifice plate, an equal pressure purging both to Hi and o pressure parts so as not to introduce liquid and/or solids into DP Pressure lead pipe. Dual mount type purge set used. For continuous measurement of density of liquid in tanks, Air purging system is used as shown above. (P-P)+ H = H Recommended Model of Purgeset: CP--AM Recommended Model of Purgeset: CP--AM TKY KEI C., TD. TG-F76-6E

3 C- TYPE TANDARD PECIFICATIN C eries PURGE ET DIMENTIN F CNTANT FW VAVE UNIT MDE IDENTIFICATIN: C- ET PREURE VARIATIN CNTR TYPE C- ET PREURE VARIATIN CNTR TYPE AVAIABE FW RANGE: 9 RC 8 GAE : Max. 3/min (nor) * MAX.P.PRE. : 0.7MPa TEMP. : Max. 0 o C *: It is general data, and the maximum temperature may change by terms of use and environment. Min. Required DP : 0.03MPa * Max. Controllable DP : 0.3MPa CNTR ACCURACY : 3%(F..) MATERIA CNTRUCTIN : PART NAME BDY DIAPHRAGM PRG EA TANDARD U U NBR MATERIA PTIN Aluminum,U36 U36 TANDARD PRCE CNNECTIN : Rc/8 Thread *: Air, 0 o C, 0MPa *: 0.05MPa for C- version EXAMPE F CMBATIN WITH FWMETER ET PREURE VARIATIN CNTR TYPE (7) RC 8 The above figure shows Type C- which is the primary pressure fluctuation type. For Type C- of the secondary pressure fluctuation type, the direction of and gets reverse, and the height shall be 35mm instead of mm. ET PREURE VARIATIN CNTR TYPE 8 CP--00 Air Min.0~00m/min (nor) (0 C, 0MPa) Max.0.3~3/min (nor) CP--00 Air Min.0~00m/min (nor) (0 C, 0MPa) Max.0.3~3/min (nor) -φ φ (00) (00) CP-- Air Min.0~00m/min (nor) (0 C, 0MPa) Max.0.3~3/min (nor) CP-- 8 Air Min.0~00m/min (nor) (0 C, 0MPa) Max.0.3~3/min (nor) -φ5.5 -φ (00) (00) TG-F76-6E TKY KEI C., TD. 3

4 C eries PURGE ET C- TYPE TANDARD PECIFICATIN MDE IDENTIFICATIN: C- ET PREURE VARIATIN CNTR TYPE C- ET PREURE VARIATIN CNTR TYPE AVAIABE FW RANGE: IQUID : Max. /min. * GAE : Max. 50/min (nor) * MAX.P.PRE. : MPa TEMP. : Max. 0 o C *: It is general data, and the maximum temperature may change by terms of use and environment. Min. Required DP : 0.06MPa Max. Controllable DP : 0.MPa CNTR ACCURACY : 5%(F..) MATERIA CNTRUCTIN : PART NAME BDY DIAPHRAGM PRG EA TANDARD C U NBR MATERIA PTIN - U36 TANDARD PRCE CNNECTIN : Thread *: Water (Density.0g/cm 3, Viscosity.0cP) *: Air, 0 o C, 0MPa CP--00 DIMENTIN F CNTANT FW VAVE UNIT RC RC RC [Without valve] 56 C- TYPE R C [With valve] C- TYPE C- TYPE EXAMPE F CMBATIN WITH FWMETER ET PREURE VARIATIN CNTR TYPE (Also used for ET PREURE VARIATIN in liquid applications) CP--00 Water Min.5~50m/min. Max.0.~/min. Air Min.0.~/min (nor) (0 C, 0MPa) Max.5~50/min (nor) CP-- Water Min.7~m/min. Max.0.~/min. Air Min.0.~/min (nor) (0 C, 0MPa) Max.5~50/min (nor) (5.5) MAX. 76 THICKNE: MAX. t HE: - φ9 (86) (5) 5 -M (.5) MAX. 76 THICKNE: MAX. t HE: - φ9 (86) 5 -M TKY KEI C., TD. TG-F76-6E

5 C eries PURGE ET CP--00 Water Min.7~m/min. Max.0.~/min. Air Min.0.~/min (nor) (0 C, 0MPa) Max.5~50/min (nor) CM--0 Wate Min.8~0m/min. Max.0.~/min. Air Min.0.~/min (nor) (0 C, 0MPa) Max.6~60/min (nor) 38 (60) (36) MAX. 7 THICKNE: MAX. t HE: -φ9 (87) 5 -M (50) MAX ET PREURE VARIATIN CNTR TYPE CP--00 Air Min.0.~/min (nor) (0 C, 0MPa) Max.5~50/min (nor) CP-- Air Min.0.~/min (nor) (0 C, 0MPa) Max.5~50/min (nor) -φ5.5 -φ CP--00 Air Min.0.~/min (nor) (0 C, 0MPa) Max.5~50/min (nor) CM--0 Air Min.0.~/min (nor) (0 C, 0MPa) Max.6~60/min (nor) -φ5.5 φ80 (MAX.6) (50) (50) TG-F76-6E TKY KEI C., TD. 5

6 C eries PURGE ET C-3 TYPE TANDARD PECIFICATIN MDE IDENTIFICATIN: C-3 ET PREURE VARIATIN CNTR TYPE C-3 ET PREURE VARIATIN CNTR TYPE AVAIABE FW RANGE: IQUID : Max. 5/min. * GAE : Max. 50/min (nor) * MAX.P.PRE. : 0.8MPa TEMP. : Max. 0 o C *: It is general data, and the maximum temperature may change by terms of use and environment. Min. Required DP : 0.MPa * Max. Controllable DP : 0.5MPa CNTR ACCURACY : 5%(F..) MATERIA CNTRUCTIN : PART NAME BDY DIAPHRAGM PRG EA TANDARD C/U U NBR MATERIA PTIN C/U36 U36 TANDARD PRCE CNNECTIN : Thread *: Water (Density.0g/cm 3, Viscosity.0cP) *: Air, 0 o C, 0MPa EXAMPE F CMBATIN WITH FWMETER ET PREURE VARIATIN CNTR TYPE (Also used for ET PREURE VARIATIN in liquid applications) CP Water Min.0.~/min. Max.0.5~5/min. Air Min.5~50/min (nor) (0 C, 0MPa) Max.5~50/min (nor) ET PREURE VARIATIN CNTR TYPE CP φ0 CP DIMENTIN F CNTANT FW VAVE UNIT C-3 φ0 Rc/8 Air Min.5~50/min (nor) (0 C, 0MPa) Max.5~50/min (nor) 65 (5) 7 (55) (3) (55) φ0 (MAX.65) (3) CM-3-0 Water Min.0.~/min. Max.0.5~5/min. Air Min.6~60/min (nor) (0 C, 0MPa) Max.5~50/min (nor) CM-3-0 φ0 Air Min.6~60/min (nor) (0 C, 0MPa) Max.5~50/min (nor) (MAX.6) (80) () 0 (50) 0 φ0 (MAX.6) (80) 6 TKY KEI C., TD. TG-F76-6E

7 C- TYPE TANDARD PECIFICATIN C eries PURGE ET DIMENTIN F CNTANT FW VAVE UNIT MDE IDENTIFICATIN: C- ET PREURE VARIATIN CNTR TYPE C- ET PREURE VARIATIN CNTR TYPE AVAIABE FW RANGE: IQUID : Max. 0/min. * GAE : Max. 0/min (nor) * φ85 MAX.P.PRE. TEMP. : 0.8MPa : Max. 0 o C 60 *: It is general data, and the maximum temperature may change by terms of use and environment. Min. Required DP : 0.MPa Max. Controllable DP : 0.6MPa CNTR ACCURACY : 5%(F..) Rc/ φ0 Rc/ MATERIA CNTRUCTIN : PART NAME BDY DIAPHRAGM PRG EA TANDARD U U NBR MATERIA PTIN U36 U36 C- TANDARD PRCE CNNECTIN : Rc/ Thread *: Water (Density.0g/cm 3, Viscosity.0cP) *: Air, 0 o C, atm EXAMPE F CMBATIN WITH FWMETER ET PREURE VARIATIN CNTR TYPE (Also used for ET PREURE VARIATIN in liquid applications) CP--500 Water Min.0.5~5/min. Max.~0/min. Air Min.5~50/min (nor) (0 C, 0MPa) Max.~0/min (nor) Rc/ ET PREURE VARIATIN CNTR TYPE CP--500 Air Min.5~50/min (nor) (0 C, 0MPa) Max.~0/min (nor) 65 Rc/ φ85 φ85 Rc/ MAX (65) () Rc/ TG-F76-6E TKY KEI C., TD. 7

8 C eries PURGE ET PECIA VERIN PANE MUNT TYPE E This is a combination of NE purge set, one filter regulator and inlet pressure gauge on one panel board. The necessary components for air purging are combined in one panel board that offers easy installation at site. table purging flow is maintained even when the secondary (load) pressure varies. BCK DIAGRAM F YTEM CNTANT FW VAVE PURGEMETER TANDARD PECIFICATIN Type : econdary pressure variation control type Refer to the specifications of each component. DIMENIN 0 ET FITER REGUATR () H PRE. GAUGE ET U bolt installation on inch pipe CP--AU 0 0 (0) () inch pipe U bolts and nuts (00) MDE CDE pecial ize Connection Panel M'tl Diaphragm M'tl Packing M'tl Wet part M'tl Mounting method Regulator and gauge Purge set Q'ty Purge meter model Constant flow valve CP- - A 0 - N C -R R 3 Rc -Z Z /8 / 3/8 / N NPT E PCC U Epoxy painting C F N C F NBR 6 Z U U36 pecial U Panel or wall mount inch pipe A ingle Dual P P--00 P C- () () () (3) () 35 3 (3) (35) () Wall or panel mount type CP--A Wall or panel mount type CP--A 8 TKY KEI C., TD. TG-F76-6E

9 C eries PURGE ET MDE CDE pecial ize Connection Panel M'tl Diaphragm M'tl Packing M'tl Wet part M'tl Mounting method Regulator and gauge Purge set Q'ty Purge meter model Constant flow valve CP- - A 0 - N C -R R 3 Rc -Z Z /8 / 3/8 / N NPT E PCC U Epoxy painting C F N C F NBR 6 Z U U36 pecial U Panel or wall mount inch pipe A ingle Dual P P--00 P C- DIMENIN U bolts and nuts M M () () (0) inch pipe Wall or panel mount type CP--A U bolt installation on inch pipe CP--AU TG-F76-6E TKY KEI C., TD. 9

10 C eries PURGE ET PECIA VERIN AIR PURGG EVE MEAUREMENT TYPE (With PGT Purging Pipe) CP--00-B E CP--00-B unit consist of a filter regulator, inlet/outlet pressure gauges and change-over valves used for changing of measuring mode or purging mode. These components are assembled into one panel board for easy installation. This unit, together with PGT purging pipe, serves for tank level measurement containing solids, particles and sticky liquids. BCK DIAGRAM F YTEM CNTANT FW VAVE PURGE METER PURGE PRE. GAUGE FITER REGUATR UPPY PRE. GAUGE AIR T UPPY PGT PURGG PIPE MDE CDE Purge set Q'ty MEAURE/BW WICH ( : ME, : BW) FRM T TRANMITTER/ PGT PURGG PIPE DICATR CP Mounting method Wet part M'tl Packing M'tl Diaphragm M'tl Panel M'tl Connection ize pecial - TANDARD PECIFICATIN Type : econdary pressure variation control type Fluid : Air upply air : 0.3~0.99MPa Primary press. : To be adjusted to 0.MPa econdary press. : 0~0.5MPa (This range shows the case when water level is 0 to 5000 mm) cale range : 0.~./min (std) (Air, 0 C, 0MPa) Indication accuracy : 5% F.. Control accuracy : 5% F.. pecial requirements ( specify the measuring length) Type : econdary pressure variation control type Fluid : Air, Nitrogen and others upply pressure : Max MPa etting press. (pressure gauge) : econdary pressure MPa econdary press. : 0~ (set press MPa) Available range (air, 0 C,atm) Min. : 0.~ /min (nor) Max. : 5~ 50 /min (nor) Indication accuracy : 5% F.. Control accuracy : 5% F. 0 TKY KEI C., TD. TG-F76-6E

11 N N N N C eries PURGE ET DIMENIN Wall or panel mount type CP--00-B U bolt installation on inch pipe CP--00-BU " Pipe ( 60.5) U bolts and nuts (00) ECNDARY REGUATR 80 0 PRIMARY BW MEAURE MAX 8 (60) MAX 8 (60) Box type CP--00-BZ Dual type CP--00-B (80) ECNDARY ECNDARY ECNDARY REGUATR 0 " Pipe ( 60.5) REGUATR REGUATR 00 PRIMARY PRIMARY Handling Remarks attached PRIMARY BW MEAURE BW MEAURE BW MEAURE (60) PANE CUT TG-F76-6E TKY KEI C., TD.

12 C eries PURGE ET PGT PURGG PIPE Material : U, U36 or PVC Pipe nominal dia. : tainless steel 0, 5, 0, 5mm PVC 8, 6mm Max. measuring length : tainless steel 6000mm (Connection of measuring length more than 000mm is socket type) PVC Max. 000mm Process connection : Fixed flange 0 mm ~ 5mm JI0K liding flange (Flange location is adjustable) 5 mm ~ 0 mm JI0K (ther flange standards are available) Connection of purging gas : Rc / screw (ther screw standards are available) PTIN DEVICE ptional parts to measure level are available. Contact us if required. FCX DIFFERENTA PREURE TRANMITTER PGT PURGG PIPE tainless steel material R T R R Tube size ( X) 0A (7.3) 5A (.7) 0A (7.) 5A (3) Fixed flange 5 d C D d X PVC material PUG R n h R D C T n h Flange std R T R 6 R liding flange 5 C D d X PUG n h FW0AJI0K F5AJI0K FW5AJI0K F0AJI0K FW0AJI0K F5AJI0K FW5AJI0K F0AJI0K Fixed flange PUG liding flange PUG n h () 3 WAY VAVE R R n h 5 R R E R T 5 R T C D C D d X d X Tube size ( X) d R R D C T E n h Flange std. 8A (8) 6A (6) FW0AJI0K F5AJI0K FW0AJI0K F0AJI0K * pecification is subject to change without notice. Head ffice : hiba Toho Building, 7 hibakoen, Minato-ku, Tokyo Tel : (KEY) ; Fax : overseas.sales@tokyokeiso.co.jp ; UR : TG-F76-6E

C-21 C-22. Gases and liquids ~0.4 ±5 Rc 1/ It is general data, and the maximum temperature may change by terms of use and environment.

C-21 C-22. Gases and liquids ~0.4 ±5 Rc 1/ It is general data, and the maximum temperature may change by terms of use and environment. TO MATA CONSTANT FOW C Series PURGE SET FOWMETER WITH CONSTANT FOW VAVE GENERA C series Constant Flow Valves keep flow rate of gases or liquids even when the supply or load pressure changes. Control valve

More information

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve) Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve) When working pressure change, inside diaphragm and needle valve operates in order to always keeping a fixed flow rate for exact

More information

FR-6000 Series OUTLINE FEATURES MAIN APPLICATIONS

FR-6000 Series OUTLINE FEATURES MAIN APPLICATIONS PREURE- TIGHT FAMEPROOF FOR HYDROGEN ATMOPHERE READY FR- eries FOAT TYPE EVE WITCH OUTINE FR- is a float-rod type level switch which applies for wide range of pressure and temperature. FR- is suitable

More information

Integral type Differential pressure flowmeter VNT Series

Integral type Differential pressure flowmeter VNT Series Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.

More information

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

ALL-IN-ONE MINI THERMAL MASS FLOWMETER INDICATION, TOTAIZATION, -POINT AARM, DC to ma AND PUSE OUTPUT BY ONE UNIT TF-T Series A-IN-ONE MINI TERMA MASS FOWMETER OUTINE TF-T MINI TERMA MASS FOWMETER is for the measurement of mass flow rate of

More information

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER GENERAL FEATURES OPERATION PRINCIPLE

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER GENERAL FEATURES OPERATION PRINCIPLE FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES TC Series THERMAL MASS FLOW CONTROLLER GENERAL TC series are thermal mass flow controllers, a combination of thermal mass flowmeter and control valve. TC

More information

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES TC Series THERMAL MASS FLOW CONTROLLER OUTLINE TC series are thermal mass flow controllers, a combination of thermal mass flowmeter and control valve. TC

More information

CASH VALVE TYPE KP BACK PRESSURE VALVES

CASH VALVE TYPE KP BACK PRESSURE VALVES A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or

More information

Flow control valves Series RFU - RFO 2/

Flow control valves Series RFU - RFO 2/ CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

Series MX pressure regulators 3/

Series MX pressure regulators 3/ CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges

More information

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following: PART 1 GENERAL 1.1 DESCRIPTION.1 This section includes the supply, delivery and installation, testing and placement into operation of a gas chlorination system, and appurtenances as specified herein and

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

Gas Pressure Regulator HON 502

Gas Pressure Regulator HON 502 Gas Pressure Regulator HON 502 Product information serving the gas industry worldwide Gas Pressure regulator HON 502 Application, Characteristics, Technical Data Application for offtake stations in gas

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class. Introduction RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class. The regulator is used for reducing and regulating the pressure of natural gases and LPG,

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

Pressure reducing valves Index

Pressure reducing valves Index Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel

More information

Bubble Tube Installations

Bubble Tube Installations Instruction MI 020-328 September 2013 Bubble Tube Installations For Liquid Level, Density, and Interface Level Measurements 2 Contents Introduction... 5 Abbreviations... 5 Principle of Operation... 5 Alternative

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

Pressure Reducing Valve DMV 750

Pressure Reducing Valve DMV 750 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Pressure Reducing Valve DMV 750 Advantages reduction

More information

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800 KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual Model GP-2000 PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

Measurement of Low GAS & Liquid Flows

Measurement of Low GAS & Liquid Flows Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300

More information

RR 16 Commercial & Industrial Regulator

RR 16 Commercial & Industrial Regulator Gas RR 16 Commercial & Industrial Regulator Applications The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations

More information

Pilot HON 630a, HON 640

Pilot HON 630a, HON 640 product information serving the gas industry worldwide pplication, characteristics, technical data pplication pilot for gas pressure regulators HON 0, HON 0, HON 0, HON 0 suitable for natural gas and all

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15 MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2012-11-11 Section 15 In order to consistently bring you the highest quality full featured products, we reserve the right

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Auto feed lube 00 00-0 00 00 00 900 - --IS- -9 AIR : OIL : Fluid Proof pressure Air. MPa 0. MPa.0 MPa (Note ) Operating pressure differential

More information

North American Orifice Metering System

North American Orifice Metering System Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual

More information

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 /

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 / SNAP-IN Purgemaster Series 0A600 Instruction Bulletin Replaceable Parts List D84B003U35 Rev. 0 / 03.200 You have purchased a high quality, modern instrument from ABB Automation Products. We thank you for

More information

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance DST100 / DST200 TYPE N2 Blanketing Valve INSTRUCTION MANUAL CONTENTS General Description Operation Installation Maintenance K.S.P.C 488-1 Wolha-ro, Tongjin-eup, Gimpo-si, Gyeonggi-Do, Korea Tel : +82-31-998-3825~7

More information

Glass tube flowmeters Series 2000

Glass tube flowmeters Series 2000 Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No

More information

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids HELYON 5 Chemin du Jubin 69570 DARDILLY Tél. +33 (0)4 72 52 16 70 - Fax +33 (0)4 72 52 16 71 R300 Brass high pressure regulator, for compressed air, gas and liquids FEATURES Pressure regulator for inlet

More information

BDT20 Safety process pressure gauge 100 & 160mm

BDT20 Safety process pressure gauge 100 & 160mm BDT20 Safety process pressure gauge 100 & 160mm Product description Badotherm pressure gauge model BDT20 is the solid front, safety pattern gauge according the highest class of the EN 837-1 / 9.7.2 and

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

RCD - Ultra-Rugged Differential Pressure Flowmeter

RCD - Ultra-Rugged Differential Pressure Flowmeter 0.15-1 to 85-600 GPM Liquids 2.5-25 to 300-1700 SCFM Gases 1/2 to 3 Line Sizes Bronze or 316-Ti Stainless Steel Mechanical Indicator, Digital Indicator, Transmitters and Switches Available Custom Calibrations

More information

Model 2851 CONSTANT FLOW REGULATOR

Model 2851 CONSTANT FLOW REGULATOR CONSTANT FLOW REGULATOR Model 2851 The model 2851 constant flow regulator is designed to provide constant flow of liquids or gases regardless of pressure variations. It is intended for low liquid flows

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

L21S/SR/ST Glass Level Gauges

L21S/SR/ST Glass Level Gauges L21S/SR/ST Glass Level Gauges Doc. no.: 150, en_cat_l21s/sr/st, 12/2014 Type of code Example: L21ST/1450/AANSI 3/4 150Lb RF/Large chamber Code 1 Basic type L21 2 Type of gauge S Tubular level gauge SR

More information

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide Pilot HON 62 Entwurf Product information serving the gas industry worldwide Pilot HON 62 Application, characteristics Application Pilot for the gas pressure regulator HON 02 Pilot for outlet pressure control

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD.

No E. General Information. Averaging Pitot Tube Flow Sensor HITROL CO., LTD. No. 2000-03E Averaging Pitot Tube Flow Sensor HITROL CO., LTD. M e a s u r e m e n t Pr i n c i p l e Measurement principle of Hitbar sensor is explained below. When a Hitbar is installed in the pipeline

More information

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting REDUING (ND HEK) VLVES RT/RG RT/RG -3// (3/8, 3/, -/) Threaded onnections / Mounting Up to MPa (5 PSI), 5 L /m in (3 U.S.GPM) Pub. E-3 Pressure Reducing Valves Pressure reducing valves are used to set

More information

Pilot Operated Check Valves

Pilot Operated Check Valves Pilot Operated Check Valves These check valves allow flow in one direction and prevent flow in the reverse direction, until operated by pilot pressure to allow free reverse flow. The specified cracking

More information

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler. Exercise 5-2 Bubblers EXERCISE OBJECTIVE Learn to measure the level in a vessel using a bubbler. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Bubblers How to measure

More information

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type. Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted

More information

Pressure Equalising Valves Model , for Differential Pressure Gauges

Pressure Equalising Valves Model , for Differential Pressure Gauges Accessories Pressure Equalising Valves Model 910.25, for Differential Pressure Gauges WIKA Data Sheet AC 09.11 Applications T Isolating, pressure equalising as well as purging and air bleeding valves to

More information

HICV Series Highly Intelligent Control Valve

HICV Series Highly Intelligent Control Valve HICV Series Highly Intelligent Control Valve Overview The HICV series (U.S. Patent No.: 6,199,582) was introduced to the t Semiconductor market in 1995, and is utilized by an array of Wet Clean and CMP

More information

Differential Pressure Transmiter

Differential Pressure Transmiter Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;

More information

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders The technical data described herein is for components of the Minimax Fire Products MX 30 Clean Agent System. For design, installation, and operation instructions, refer to the latest edition of the original

More information

Radar, Ultrasonic and RF Level Transmitters

Radar, Ultrasonic and RF Level Transmitters Radar, Ultrasonic and RF Level Transmitters Both measures the time it takes the wave to travel between the transmitter and that reflected wave off the surface of the material to reach the transmitter again.

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

Chlorinator. MODEL C-731 (Floor Mounted)

Chlorinator. MODEL C-731 (Floor Mounted) Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive

More information

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2 FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel L Compact /, High Flow / - / Air service equipment Series FEATURES Stainless Steel filter, regulator and filter regulator intended for corrosive environment

More information

Orifice Plate Flow Meter

Orifice Plate Flow Meter Orifice Plate Flow Meter FOFT Measuring Principle The principle of measuring the differential pressure is based on the fact that a differential pressure is created across that section of a pipe where its

More information

SINGLE VALVE WITH LOW-FLOW BYPASS

SINGLE VALVE WITH LOW-FLOW BYPASS CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size

More information

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES.

BULLETIN FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES. BULLETIN 20-7000 ROTAMETERS PURGE FOR ACCURATE INDICATION AND CONTROL OF GAS AND LIQUID FLOW IN LOW RANGES. INTRODUCTION McCrometer purge rotameters are precision-made instruments designed to accurately

More information

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Description Supply pressure Pressure range Connection Device Page max. bar bar thread Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4

More information

Excellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA

Excellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA Excellent Vortex meter INSERTION Type BATTERY POWERED EX DELTA GENERAL SPECIFICATION GS.No.GBD604E-6 GENERAL The battery-powered EX DELTA is a dedicated on site monitor with a wide variety of applications

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic

More information

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level

More information

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No

More information

Purge Device KPTD/KPTK/KPTH

Purge Device KPTD/KPTK/KPTH Purge Device KPTD/KPTK/KPTH KPTD/KPTK/KPTH 2: principle as shown in figure blow:(invariableness inlet pressure) elasticity membrane have the up power P2A+P1a(1) elasticity membrane have the down power:

More information

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder

More information

CLASS TLP Pressure Reducing Valve

CLASS TLP Pressure Reducing Valve CLASS TLP Pressure Reducing Valve CLASS TLP Direct Acting Pressure Reducing Valve The Class TLP balanced direct acting pressure regulator is designed for use on installations that have varying inlet pressures

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators 61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally

More information

EPOXY FITTINGS DIMENSIONS

EPOXY FITTINGS DIMENSIONS Bulletin No. A150 May 1, 2004 EPOXY FITTINGS DIMENSIONS 2"-16" GREEN THREAD fittings may be used with GREEN THREAD and RED THREAD II piping. Refer to Chemical Resistance Guide, Bulletin No. E5615, for

More information

B74G - EXCELON Modular System General purpose filter/regulator

B74G - EXCELON Modular System General purpose filter/regulator > Port size: /8... / (ISO G/PTF) > Excelon design allows in-line installation or modular installation with other Excelon products > Push to lock adjusting knob with optional tamper resistant accessory

More information

Variable area flowmeter F VA 250

Variable area flowmeter F VA 250 Fig. variable area flow meter pplication The V 5 variable area flowmeters with a standard length of 5 mm (9.84 inch) and a completely metal design can be used to measure many different types of liquids

More information

DANFLO Control Valves 400 Series Model 20

DANFLO Control Valves 400 Series Model 20 DANFLO Control Valves 400 Series Model 20 Back Pressure/Pressure Relief The DANFLO Model 20 is a pilot operated valve suitable for use in gas or liquid facilities and requires no outside power for operation.

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa 0. MPa.0 MPa (Note

More information

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 0 PROJECT : QUANTITY : 0 LOCATION : SERVICE : FOAM SYSTEM 0 05 CODE & STANDARDS

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES PRESSURE REGULATORS ALL MEDICAL GASES In this section we propose our pressure regulators (FM series, MU and MERCURY ) and our Rs flowmeters for applications other than oxygen therapy (presented in the

More information

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw. Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces

More information

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters Data Sheet DS/NDA-EN Rev. H Model NDA Differential pressure transmitter Deltapi N Series A complete range of pneumatic pressure transmitters Introduction The blind type differential pressure transmitter

More information

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New > Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,

More information

SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3

SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3 Contents SITRANS F I Gardex Flowmeter English General 1 SITRANS F I Gardex 2 SITRANS F I Intra/Prima 3 SITRANS F I Intra/Prima Flap Flowmeter Instructions A5E00129182 Version 02 09/2003 SITRANS F ED Automatic

More information

Rate of Flow Valve Series 120

Rate of Flow Valve Series 120 SPECIFICATIONS Rate of Flow Valve Series DIMENSIONS The OCV Series 120 Rate of Flow control valve is designed to control or limit flow to a predetermined rate, regardless offl uctuations in downstream

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening)

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Type Type Differential Pressure Regulators (opening) Self-operated Pressure Regulators Type 42-20 Type 42-25 Differential Pressure Regulators (opening) Translation of original instructions Type 42-20 Differential Pressure Regulator Type 42-25 Differential

More information

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator January 2009 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator Introduction The Type 310A pilot-operated high-pressure regulator (Figure 1) is used where high capacity

More information

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S06* Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

TECHNICAL ACCESSORIES

TECHNICAL ACCESSORIES A.R.I. VALVES S-050P AIR PLASTIC RELEASE 16 BAR Automatic Component A.R.I patent, Rolling Seal Mechanism: Dramatically reduces the possibility of obstruction by debris. Discharges high air flow rates upto

More information

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION

XDF BURNERS DUAL FUEL EXCESS AIR BURNER FEATURES DESCRIPTION EXCESS AIR OPERATION DUAL FUEL EXCESS AIR BURNER MODEL: 3610, 3651 Revision: 0 FEATURES Burns all fuel gases or light oils Nozzle mix design for on ratio control or excess air 350% excess air all sizes on gas or oil Turndown

More information

Mounting and Operating Instructions EB 9519 EN. Differential Pressure and Flow Meter Media 5. Zero adjuster

Mounting and Operating Instructions EB 9519 EN. Differential Pressure and Flow Meter Media 5. Zero adjuster Differential Pressure and Flow Meter Media 5 Zero adjuster Fig. 1 Media 5 with limit switches, attached valve block and pressure gauge Mounting and Operating Instructions EB 9519 EN Edition April 2004

More information

Airpel -FFR Overview PUB# FFRP-04R. Airpot, Airpel, and Anti-Stiction are registered trademarks of Airpot Corporation

Airpel -FFR Overview PUB# FFRP-04R. Airpot, Airpel, and Anti-Stiction are registered trademarks of Airpot Corporation Airpel -FFR Overview Airpot s pneumatic accessories and filter/regulator systems offer engineers, designers and manufacturing professionals the precise control, optimal air quality and properly sized components

More information

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators July 2010 W3716 W3507 Type 1808 Type 1808A Figure 1. Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

More information

Product Data Screwed Valves

Product Data Screwed Valves Screwed Valves Brass and Chrome PVC Stainless Steel Flow Control Check Valves - 15mm Flow Control Check Valves - 25mm AUSTRALIA Maric Brass & Chrome Screwed Valves p. 28 Availability & Specifications Maric

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to

More information

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94 Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ Compact Regulator 2 Series 2. MPa compatible, piston type compact regulator V SR X AP1 Compatible with inlet supply pressure of 2. MPa Employs a knob shape for easy operation Compact type (face to face

More information

T EK-COR 1100A. Coriolis Mass Flowmeter. FLOW. Technology Solutions

T EK-COR 1100A. Coriolis Mass Flowmeter.   FLOW. Technology Solutions Technology Solutions T EK-COR 1100A Coriolis Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction There can often be more than one type

More information

Mechanical Pressure Measurement

Mechanical Pressure Measurement Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement

More information