C-21 C-22. Gases and liquids ~0.4 ±5 Rc 1/ It is general data, and the maximum temperature may change by terms of use and environment.

Size: px
Start display at page:

Download "C-21 C-22. Gases and liquids ~0.4 ±5 Rc 1/ It is general data, and the maximum temperature may change by terms of use and environment."

Transcription

1 TO MATA CONSTANT FOW C Series PURGE SET FOWMETER WITH CONSTANT FOW VAVE GENERA C series Constant Flow Valves keep flow rate of gases or liquids even when the supply or load pressure changes. Control valve with diaphragm automatically acts following the change of pressure. They are normally delivered together with flowmeter as a "Purge set". Primary(Inlet) pressure variation control type and Secondary(Outlet) pressure variation control type are ready to meet all possible applications. EUP Type Measuring Fluid Max. Fluid Press. (MPa) Max. Fluid Temp. ( O C) Controllable Dp range (MPa) Control Accuracy (%,F.S.) Process connection Approx. MASS (kg) C-11 P1(ET) Variation C-12 P2(ET) Variation Gases only C ~0.3 C ~0.3 ±3 Rc 1/8 0.2 C-21 P1(ET) Variation C-22 P2(ET) Variation Gases and liquids ~0.4 ±5 Rc 1/4 0.9 C-31 P1(ET) Variation C-32 P2(ET) Variation Gases and liquids It is general data, and the maximum temperature may change by terms of use and environment. 0.1~0.5 ±5 Rc 3/8 2.3 C-41 P1(ET) Variation C-42 P2(ET) Variation Gases and liquids ~0.6 ±5 Rc 1/2 8.0 OPERATION PRCIPE In the PRIMARY (ET) PRESSURE VARIATION CONTRO TYPE, the fluid, of which inlet pressure varies, is introduced from to the lower chamber of the C series Constant Flow Valve. The load pressure (Secondary pressure) is connected to the upper chamber. The differential pressure between the lower chamber and the upper chamber is always constant thanks to the function of the Spring and the Diaphragm. The differential pressure across the needle valve is kept always constant and the flow rate of the fluid is proportional only to the opening of needle valve. The opposite action is taken for SECONDARY (ET) PRESSURE VARIATION CONTRO TYPE and the flow rate is kept also constant even when the load pressure changes. Upper chamber Spring Upper chamber Diaphragm Diaphragm Spring ower chamber Control Valve part ower chamber Control Valve part Outlet (Pressure constant) Needle valve Inlet (Press. variation) Inlet (Pressure constant) Needle valve Outlet (Press. variation) PRIMARY (ET) PRESSURE VARIATION CONTRO TYPE (C- 1) SECONDARY (ET) PRESSURE VARIATION CONTRO TYPE (C- 2)

2 C Series PURGE SET APPICATIONS SUPPY PRESSURE VARIATION EVE MEASUREMENT P Pressure Gauge/DP Transmitter Main valve Gus supply H Purge set Branch valve Purge set Air supply As shown above, in case one large supply line branches into several lines and the supply pressure changes because of stoppage of some branches. Primary Pressure Variation type Purge set will be suitable in keeping the purging volume of fluid. iquid level in tanks is measured by the Back-pressure at the edge of purging pipe. The outlet pressure at the tank bottom changes depending on the liquid level, and constant bubbling is required. Thus, Secondary Pressure Variation type purge set is used for this application. A DP transmitter is often connected to pressure line instead of pressure gauge for remote transmission. Recommended Model of Purgeset: CP- 1- Recommended Model of Purgeset: CP- 2-, CP B P H = ρ PURGG FOR ORIFICE PATE APPICATION DENSITY MEASUREMENT Orifice plate P1 P2 DP Transmitter DP Gauge/ DP Transmitter Purge set H1 H2 Purge set 1 2 Refarence tank Air supply Air supply For the measurement of flow rate of corrosive liquids and/or liquids with solids by orifice plate, an equal pressure purging both to Hi and o pressure parts so as not to introduce liquid and/or solids into DP Pressure lead pipe. Dual mount type purge set used. For continuous measurement of density of liquid in tanks, Air purging system is used as shown above. (P1-P2)+ ρ2h2 ρ 1 = H1 Recommended Model of Purgeset: CP-221-2A Recommended Model of Purgeset: CP-221-2A 2 TOKYO KEISO CO., TD. TG-F746-11E

3 C-1 TYPE STANDARD SPECIFICATION MODE IDENTIFICATION: C-11 ET PRESSURE VARIATION CONTRO TYPE C-12 ET PRESSURE VARIATION CONTRO TYPE AVAIABE FOW RANGES: GASES : Max. 3/min (nor) (Air 0 o C, 0MPa) FUID PRESS. : MAX. 0.7MPa FUID TEMP. : Max. 1 o C It is general data, and the maximum temperature may change by terms of use and environment. Min. Required DP : 0.03MPa (C-11) 0.05MPa (C-12) Max. Controllable DP : 0.3MPa CONTRO ACCURACY : ±3%(F.S.) PROCESS CONNECTION : Rc1/8 MATERIA CONSTRUCTION : PART NAME BODY DIAPHRAGM SPRG SEA STANDARD SUS4 Chloroprene rubber (CR) SUS4 Nitrile rubber (NBR) MATERIA OPTION Aluminum,SUS316 Fluoro rubber SUS316 Fluoro rubber C Series PURGE SET DIMENTION OF CONSTANT FOW VAVE UNIT C-11 C-12 Rc1/ (72) Rc1/8 28 Rc1/ (72) Rc1/8 28 EXAMPES OF COMBATION WITH FOWMETER ET PRESSURE VARIATION CONTRO TYPE ET PRESSURE VARIATION CONTRO TYPE CP Air Min.10~100m/min (nor) (0 C, 0MPa) Max.0.3~3/min (nor) CP Air Min.10~100m/min (nor) (0 C, 0MPa) Max.0.3~3/min (nor) () (1) (100) (1) (100) () CP-11- Air Min.10~100m/min (nor) (0 C, 0MPa) Max.0.3~3/min (nor) CP-12- Air Min.10~100m/min (nor) (0 C, 0MPa) Max.0.3~3/min (nor) () (225) (100) (225) (100) () TG-F746-11E TOKYO KEISO CO., TD. 3

4 C Series PURGE SET C-2 TYPE STANDARD SPECIFICATION MODE IDENTIFICATION: C-21 ET PRESSURE VARIATION CONTRO TYPE C-22 ET PRESSURE VARIATION CONTRO TYPE AVAIABE FOW RANGES: IQUIDS : Max. 2/min. (Water Density 1.0g/cm 3, Viscosity 1.0mPa s) GASES : Max. 50/min (nor) (Air 0 o C, 0MPa) FUID PRESS. : MAX. 1MPa FUID TEMP. : Max. 1 o C It is general data, and the maximum temperature may change by terms of use and environment. Min. Required DP : 0.06MPa Max. Controllable DP : 0.4MPa CONTRO ACCURACY : ±5%(F.S.) STANDARD PROCESS CONNECTION : MATERIA CONSTRUCTION : PART NAME MATERIA STANDARD OPTION BODY SCS14 DIAPHRAGM Chloroprene rubber (CR) Fluoro rubber SPRG SUS4 SUS316 SEA Nitrile rubber (NBR) Fluoro rubber In the C-22 type, standard material for the diaphragm is fluoro rubber. Chloroprene rubber (CR) is optional C O (67) CP DIMENTION OF CONSTANT FOW VAVE UNIT [Without valve] C-21 TYPE C O (67) 93 (MAX.35) 2 M5 (MAX.35) 2 M5 C-22 TYPE [With valve] C-21 TYPE EXAMPES OF COMBATION WITH FOWMETER ET PRESSURE VARIATION CONTRO TYPE (Also used for ET PRESSURE VARIATION in liquid applications) CP Water Min.5~50m/min. Max.0.4~2/min. Air Min.0.1~1/min (nor) (0 C, 0MPa) Max.5~50/min (nor) CP-21- Water Min.7~m/min. Max.0.2~2/min. Air Min.0.1~1/min (nor) (0 C, 0MPa) Max.5~50/min (nor) O S (1.5) MAX. 76 THICKNESS: MAX. t 4 HOE: 2 - ϕ19 (86) (115) 25 4-M O 56 S (2.5) MAX. 76 THICKNESS: MAX. t 4 HOE: 2 - ϕ19 (86) 25 4-M TOKYO KEISO CO., TD. TG-F746-11E

5 C Series PURGE SET CP-21-0 Water Min.7~m/min. Max.0.2~2/min. Air Min.0.1~1/min (nor) (0 C, 0MPa) Max.5~50/min (nor) CM-21-0 Wate Min.8~m/min. Max.0.2~2/min. Air Min.0.2~1/min (nor) (0 C, 0MPa) Max.6~/min (nor) 38 (1) O 56 S (236) MAX. 71 THICKNESS: MAX. t 4 HOE: 2 -ϕ19 (87) 25 4-M (250) MAX ET PRESSURE VARIATION CONTRO TYPE CP Air Min.0.1~1/min (nor) (0 C, 0MPa) Max.5~50/min (nor) CP-22- Air Min.0.1~1/min (nor) (0 C, 0MPa) Max.5~50/min (nor) 4-ϕ5.5 4-ϕ CP-22-0 Air Min.0.1~1/min (nor) (0 C, 0MPa) Max.5~50/min (nor) CM-22-0 Air Min.0.2~1/min (nor) (0 C, 0MPa) Max.6~/min (nor) 4-ϕ ϕ80 (MAX.61) (150) 2- (250) TG-F746-11E TOKYO KEISO CO., TD. 5

6 OPEN SHUT OPEN SHUT C Series PURGE SET C-3 TYPE STANDARD SPECIFICATION MODE IDENTIFICATION: C-31 ET PRESSURE VARIATION CONTRO TYPE C-32 ET PRESSURE VARIATION CONTRO TYPE AVAIABE FOW RANGES: IQUIDS : Max. 5/min. (Water Density 1.0g/cm3, Viscosity 1.0mPa s) GASES : Max. 150/min (nor) (Air 0 C, 0MPa) FUID PRESS. : MAX. 0.8MPa FUID TEMP. : Max. 1 C It is general data, and the maximum temperature may change by terms of use and environment. Min. Required DP : 0.1MPa Max. Controllable DP : 0.5MPa CONTRO ACCURACY : ±5%(F.S.) STANDARD PROCESS CONNECTION : MATERIA CONSTRUCTION : PART NAME BODY DIAPHRAGM SPRG SEA STANDARD SCS14/SUS4 Chloroprene rubber (CR) SUS4 Nitrile rubber (NBR) MATERIA OPTION SCS14/SUS316 Fluoro rubber SUS316 Fluoro rubber CP DIMENTION OF CONSTANT FOW VAVE UNIT C-31 Rc1/8 EXAMPES OF COMBATION WITH FOWMETER ET PRESSURE VARIATION CONTRO TYPE (Also used for ET PRESSURE VARIATION in liquid applications) CP Water Min.0.2~2/min. Max.0.5~5/min. Air Min.5~50/min (nor) (0 C, 0MPa) Max.15~150/min (nor) (75) ET PRESSURE VARIATION CONTRO TYPE CP Air Min.5~50/min (nor) (0 C, 0MPa) Max.15~150/min (nor) 110 (MAX.65) (154) (236) (155) (2) (1) 110 (MAX.65) (154) (75) CM-31-0 Water Min.0.2~2/min. Max.0.5~5/min. Air Min.6~/min (nor) (0 C, 0MPa) Max.15~150/min (nor) CM-32-0 ϕ110 Air Min.6~/min (nor) (0 C, 0MPa) Max.15~150/min (nor) (MAX.61) (180) (2) 2 (250) 2 72 ϕ110 ϕ110 (MAX.61) (180) 6 TOKYO KEISO CO., TD. TG-F746-11E

7 OPEN SHUT OPEN SHUT C-4 TYPE STANDARD SPECIFICATION C Series PURGE SET DIMENTION OF CONSTANT FOW VAVE UNIT MODE IDENTIFICATION: C-41 ET PRESSURE VARIATION CONTRO TYPE C-42 ET PRESSURE VARIATION CONTRO TYPE AVAIABE FOW RANGES: IQUIDS : Max. 10/min. (Water Density 1.0g/cm3, Viscosity 1.0mPa s) GASES : Max. 0/min (nor) (Air 0 C, 0MPa) FUID PRESS. : MAX. 0.8MPa FUID TEMP. : Max. 1 o C It is general data, and the maximum temperature may change by terms of use and environment. Min. Required DP : 0.1MPa Max. Controllable DP : 0.6MPa CONTRO ACCURACY : ±5%(F.S.) STANDARD PROCESS CONNECTION : Rc1/2 MATERIA CONSTRUCTION : Rc1/2 ϕ185 ϕ1 Rc1/2 1 PART NAME BODY DIAPHRAGM SPRG O-ring STANDARD SUS4 Chloroprene rubber (CR) SUS4 Nitrile rubber (NBR) MATERIA OPTION SUS316 Fluoro rubber SUS316 Fluoro rubber C-41 EXAMPES OF COMBATION WITH FOWMETER ET PRESSURE VARIATION CONTRO TYPE (Also used for ET PRESSURE VARIATION in liquid applications) CP Water Min.0.5~5/min. Max.1~10/min. Air Min.15~150/min (nor) (0 C, 0MPa) Max.~0/min (nor) ET PRESSURE VARIATION CONTRO TYPE CP Air Min.15~150/min (nor) (0 C, 0MPa) Max.~0/min (nor) (75) Rc1/2 185 (MAX.65) Rc1/2 (239) (2) 185 (MAX.65) Rc1/2 (75) Rc1/2 TG-F746-11E TOKYO KEISO CO., TD. 7

8 H H C Series PURGE SET SPECIA VERSIONS PANE MOUNT TYPE E This is a combination of ONE purge set, one filter regulator and inlet pressure gauge on one panel board. The necessary components for air purging are combined in one panel board that offers easy installation at site. Stable purging flow is maintained even when the secondary (load) pressure varies. BOCK DIAGRAM OF SYSTEM CONSTANT FOW VAVE PURGEMETER ET FITER REGUATOR PRESS. GAUGE ET STANDARD SPECIFICATION Type : Secondary pressure variation control type Refer to the specifications of each component. (The maximum fluid temperature is C. Models for higher fluid temperature are available as option.) DIMENSION (42) inch pipe () U-Bolts and Nuts MODE CODE * For Epoxy painting, specify S/E or 4/E. 2 U bolt installation on 2 inch pipe CP-121-1AU (68) (42) (42) (42) H (68) (35) (68) (35) Wall or panel mount type CP-121-1AO Wall or panel mount type CP-121-2AO 8 TOKYO KEISO CO., TD. TG-F746-11E

9 H C Series PURGE SET MODE CODE * For Epoxy painting, specify S/E or 4/E. DIMENSION (42) (42) H (35) (68) (35) (68) Wall or panel mount type CP-221-1AO U bolt installation on 2 inch pipe CP-221-1AU TG-F746-11E TOKYO KEISO CO., TD. 9

10 C Series PURGE SET SPECIA VERSIONS AIR PURGG EVE MEASUREMENT TYPE (With PGT Purging Pipe) CP B E CP B unit consist of a filter regulator, inlet/outlet pressure gauges and change-over valves used for changing of measuring mode or purging mode. These components are assembled into one panel board for easy installation. This unit, together with PGT purging pipe, serves for tank level measurement containing solids, particles and sticky liquids. BOCK DIAGRAM OF SYSTEM CONSTANT FOW VAVE PURGE METER PURGE PRESS. GAUGE FITER REGUATOR STANDARD SPECIFICATION Type : Secondary pressure variation control type SUPPY PRESS. GAUGE MEASURE/BOW SWICH ( : MES, : BOW) Fluid Supply air Primary press. : Air : 0.3~1 MPa : To be adjusted to 0.2 MPa Secondary press. : 0~0.15 MPa AIR TO SUPPY PGT PURGG PIPE FROM TO TRANSMITTER/ PGT PURGG PIPE DICATOR Scale range (This range shows the case when water level is 0 to mm) : 0.12~1.2/min (std) (Air, C, 0MPa) MODE CODE * For Epoxy painting, specify S/E or 4/E. Indication accuracy : ±5% F.S. Control accuracy : ±5% F.S. Fluid temp. : Max. C (models for higher fluid temperature are available as option.) Paint color : Munsell 7.5BG4/1.5 Special requirements (specify the measuring length) Type : Secondary pressure variation control type Fluid : Air, Nitrogen and others Supply pressure : Max. 1 MPa Setting press. (pressure gauge) : Secondary pressure MPa Secondary press. : 0~ (set press MPa) Available range (air, 0 C, 0MPa) Min. : 0.1~1 /min (nor) Max. : 5~ 50 /min (nor) Indication accuracy : ±5% F.S. Control accuracy : ±5% F.S. 10 TOKYO KEISO CO., TD. TG-F746-11E

11 N N N N C Series PURGE SET DIMENSION Wall or panel mount type CP B U bolt installation on 2 inch pipe CP BU 2" Pipe (.5) U bolts and nuts (SS0) SECONDARY REGUATOR PRIMARY BOW MEASURE MAX 48 (1) PANE CUT MAX 48 (1) Box type CP BZ Dual type CP B 2 (280) SECONDARY SECONDARY 1 SECONDARY REGUATOR 0 2" Pipe (.5) REGUATOR REGUATOR 0 PRIMARY PRIMARY Handling Remarks attached PRIMARY 1 BOW MEASURE BOW MEASURE BOW MEASURE (1) PANE CUT TG-F746-11E TOKYO KEISO CO., TD. 11

12 C Series PURGE SET PGT PURGG PIPE Material : SUS4, SUS316 or PVC Pipe size : Stainless steel 10, 15,, 25mm PVC 18, 26mm Max. measuring length : Stainless steel 100mm (Connection of measuring length more than 00mm is socket type) PVC Max.00mm Process connection : Fixed flange 10 to 25mm JIS10K Sliding flange (Flange location is adjustable) 15 to mm JIS10K (Other flange standards are available) Connection of purging gas : Rc 1/4 (Other screw standards are available) OPTION DEVICES Optional parts to measure level are available. Contact us if required. FKC DIFFERENTA PRESSURE TRANSMITTER PGT PURGG PIPE Stainless steel material 2 T 1 Size ( X) 10A (17.3) 15A (21.7) A (27.2) 25A (34) Fixed flange (FW) d C D d X PUG n h D C T n h Flange std T Sliding flange (FS) C D d X PUG 1 n h FW10AJIS10K FS15AJIS10K FW15AJIS10K FSAJIS10K FWAJIS10K FS25AJIS10K FW25AJIS10K FSAJIS10K PVC material Fixed flange (FW) PUG Sliding flange (FS) PUG 3 WAY VAVE n h 2 n h (112) 1 E 2 T T C D C D 1 d X d X Size ( X) 18A (18) 26A (26) d D C T E n h Flange std FW10AJIS10K FS25AJIS10K FWAJIS10K FSAJIS10K * Specification is subject to change without notice. Head Office : Shiba Toho Building, Shibakoen, Minato-ku, Tokyo Tel : (KEY) ; Fax : overseas.sales@tokyokeiso.co.jp ; UR : 12 TG-F746-11E

C-21 C-22. Gases and liquids ~0.4 5 Rc 1/4 thread 0.9

C-21 C-22. Gases and liquids ~0.4 5 Rc 1/4 thread 0.9 T MATA CNTANT FW C eries PURGE ET FWMETER WITH CNTANT FW VAVE GENERA C series Constant Flow Valves keep flow rate of gases or liquids even when the supply or load pressure changes. Control valve with diaphragm

More information

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve)

Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve) Panel-Mounting Flowmeters Purge Set (Flowmeter with Constant Flow Valve) When working pressure change, inside diaphragm and needle valve operates in order to always keeping a fixed flow rate for exact

More information

ALL-IN-ONE MINI THERMAL MASS FLOWMETER

ALL-IN-ONE MINI THERMAL MASS FLOWMETER INDICATION, TOTAIZATION, -POINT AARM, DC to ma AND PUSE OUTPUT BY ONE UNIT TF-T Series A-IN-ONE MINI TERMA MASS FOWMETER OUTINE TF-T MINI TERMA MASS FOWMETER is for the measurement of mass flow rate of

More information

Integral type Differential pressure flowmeter VNT Series

Integral type Differential pressure flowmeter VNT Series Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.

More information

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER GENERAL FEATURES OPERATION PRINCIPLE

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER GENERAL FEATURES OPERATION PRINCIPLE FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES TC Series THERMAL MASS FLOW CONTROLLER GENERAL TC series are thermal mass flow controllers, a combination of thermal mass flowmeter and control valve. TC

More information

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE

TC Series FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES THERMAL MASS FLOW CONTROLLER OUTLINE FEATURES OPERATION PRINCIPLE FOR THE MASS FLOW CONTROL OF ALL KIND OF GASES TC Series THERMAL MASS FLOW CONTROLLER OUTLINE TC series are thermal mass flow controllers, a combination of thermal mass flowmeter and control valve. TC

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

Gas Pressure Regulator HON 502

Gas Pressure Regulator HON 502 Gas Pressure Regulator HON 502 Product information serving the gas industry worldwide Gas Pressure regulator HON 502 Application, Characteristics, Technical Data Application for offtake stations in gas

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

CASH VALVE TYPE KP BACK PRESSURE VALVES

CASH VALVE TYPE KP BACK PRESSURE VALVES A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

TH-1800-T TRX-700-CNG Converter

TH-1800-T TRX-700-CNG Converter TH-1800-T TRX-700-CNG Converter low detector The CNG fuel gas flowmeter is so accurate as to meet a demand of measuring the CNG directly by making the most use of our well-established mini-thermal flowmeter

More information

Pressure reducing valves Index

Pressure reducing valves Index Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel

More information

Bubble Tube Installations

Bubble Tube Installations Instruction MI 020-328 September 2013 Bubble Tube Installations For Liquid Level, Density, and Interface Level Measurements 2 Contents Introduction... 5 Abbreviations... 5 Principle of Operation... 5 Alternative

More information

CLASS TLP Pressure Reducing Valve

CLASS TLP Pressure Reducing Valve CLASS TLP Pressure Reducing Valve CLASS TLP Direct Acting Pressure Reducing Valve The Class TLP balanced direct acting pressure regulator is designed for use on installations that have varying inlet pressures

More information

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class. Introduction RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class. The regulator is used for reducing and regulating the pressure of natural gases and LPG,

More information

Norval Pressure regulator

Norval Pressure regulator Norval Pressure regulator NORVAL Classification and Field of Application The NORVAL is a downstream pressure regulator, self actuated, spring loaded for medium and low pressure applications. It is suitable

More information

Flow control valves Series RFU - RFO 2/

Flow control valves Series RFU - RFO 2/ CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5

More information

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type. Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted

More information

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following: PART 1 GENERAL 1.1 DESCRIPTION.1 This section includes the supply, delivery and installation, testing and placement into operation of a gas chlorination system, and appurtenances as specified herein and

More information

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators 61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally

More information

RR 16 Commercial & Industrial Regulator

RR 16 Commercial & Industrial Regulator Gas RR 16 Commercial & Industrial Regulator Applications The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

Excellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA

Excellent Vortex Flowmeter INSERTION Type BATTERY POWERED EX DELTA Excellent Vortex meter INSERTION Type BATTERY POWERED EX DELTA GENERAL SPECIFICATION GS.No.GBD604E-6 GENERAL The battery-powered EX DELTA is a dedicated on site monitor with a wide variety of applications

More information

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

Series MX pressure regulators 3/

Series MX pressure regulators 3/ CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges

More information

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual Model GP-2000 PRESSURE REDUCING VALVE Installation & Operation Manual Please read this bulletin thoroughly before using the pressure reducing valve, so that you may do so correctly and safely. Please carefully

More information

SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3

SITRANS F I Gardex. Flowmeter. SITRANS F I Intra/Prima. Flap Flowmeter. Contents. English. General 1. SITRANS F I Gardex 2. SITRANS F I Intra/Prima 3 Contents SITRANS F I Gardex Flowmeter English General 1 SITRANS F I Gardex 2 SITRANS F I Intra/Prima 3 SITRANS F I Intra/Prima Flap Flowmeter Instructions A5E00129182 Version 02 09/2003 SITRANS F ED Automatic

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions

The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions The M-Series Eletta Flow Meter High accuracy DP Flow Meter with multiple functions Flow Meter with multiple functions for gases and liquids M3 The M-series Flow Meter, with its versatile and user-friendly

More information

FR-6000 Series OUTLINE FEATURES MAIN APPLICATIONS

FR-6000 Series OUTLINE FEATURES MAIN APPLICATIONS PREURE- TIGHT FAMEPROOF FOR HYDROGEN ATMOPHERE READY FR- eries FOAT TYPE EVE WITCH OUTINE FR- is a float-rod type level switch which applies for wide range of pressure and temperature. FR- is suitable

More information

B74G - EXCELON Modular System General purpose filter/regulator

B74G - EXCELON Modular System General purpose filter/regulator > Port size: /8... / (ISO G/PTF) > Excelon design allows in-line installation or modular installation with other Excelon products > Push to lock adjusting knob with optional tamper resistant accessory

More information

Actuator HON 670 / 671

Actuator HON 670 / 671 Actuator HON 670 / 67 Product information serving the gas industry worldwide Applications, characteristics, technical data Application The actuators HON 670 (K6, K8) and HON 67 (K7) are used to trigger

More information

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level

More information

Pilot HON 630a, HON 640

Pilot HON 630a, HON 640 product information serving the gas industry worldwide pplication, characteristics, technical data pplication pilot for gas pressure regulators HON 0, HON 0, HON 0, HON 0 suitable for natural gas and all

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

Rate of Flow Valve Series 120

Rate of Flow Valve Series 120 SPECIFICATIONS Rate of Flow Valve Series DIMENSIONS The OCV Series 120 Rate of Flow control valve is designed to control or limit flow to a predetermined rate, regardless offl uctuations in downstream

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

B84G - Excelon Plus Modular System General purpose filter/regulator

B84G - Excelon Plus Modular System General purpose filter/regulator > Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant

More information

Chlorinator. MODEL C-731 (Floor Mounted)

Chlorinator. MODEL C-731 (Floor Mounted) Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive

More information

Safety Shut-Off Valve HON 720

Safety Shut-Off Valve HON 720 Safety Shut-Off Valve HON 70 Product information serving the gas industry worldwide Application, Characteristics, Technical Data Application main safety device for gas pressure regulating stations suitable

More information

RTG 25. Introduction

RTG 25. Introduction Introduction RTG 25 pressure regulator is included within the direct acting and balanced valve regulator class. These regulators have a large range of applications both in industrial and domestic installations.

More information

FLOW CONTROL VALVES FLOW CONTROL VALVE HF WITH PRESSURE COMPENSATION SIZE 01 E 4. Description of the model designation. Outside dimensions

FLOW CONTROL VALVES FLOW CONTROL VALVE HF WITH PRESSURE COMPENSATION SIZE 01 E 4. Description of the model designation. Outside dimensions FLOW CONTROL VALV HF WITH PRSSUR COMPNSATION SIZ it incorporates a pressure compensation mechanism, the flow is kept constant even if the pressure varies at the and/or port. When equipped with a check

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

GAS PRESSURE REGULATORS AP

GAS PRESSURE REGULATORS AP A Long Experience in Energy Equipment and one Goal: The Customer s satisfaction. GAS PRESSURE REGULATORS AP (High Pressure) ALPHARD P/AP Pressure Regulator Applications It is designed for use in transmission

More information

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3, 4, 6 Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with

More information

Glass tube flowmeters Series 2000

Glass tube flowmeters Series 2000 Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No

More information

Pressure Reducing Valve DMV 750

Pressure Reducing Valve DMV 750 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Pressure Reducing Valve DMV 750 Advantages reduction

More information

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators July 2010 W3716 W3507 Type 1808 Type 1808A Figure 1. Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

More information

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide Pilot HON 62 Entwurf Product information serving the gas industry worldwide Pilot HON 62 Application, characteristics Application Pilot for the gas pressure regulator HON 02 Pilot for outlet pressure control

More information

ASX 176 Axial Pressure regulator

ASX 176 Axial Pressure regulator ASX 176 Axial Pressure regulator ASX 176 Classification and Area of Application ASX 176 is a downstream pressure regulator, pilot controlled, for medium and high pressure applications. It is particularly

More information

T208VR Series Tank Blanketing Vacuum Regulator

T208VR Series Tank Blanketing Vacuum Regulator February 2014 T208VR Series Tank Blanketing Vacuum Regulator Figure 1. Typical T208VR Series Vacuum Regulator Introduction The T208VR Series direct-operated vacuum regulators are used where a decrease

More information

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications Outstanding performance in extremely low pressure and low pressure ranges from 0.003 to. Realizing high performance, energy saving, and compact size. Realize precise pressure control in a pressure range

More information

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800 KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

AIR FOAM CHAMBER DATA SHEET

AIR FOAM CHAMBER DATA SHEET FIRE FIGHTING EQUIPMENT DATA SHEET AIR FOAM CHAMBER DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 02 PROJECT : QUANTITY : 03 LOCATION : SERVICE : FOAM SYSTEM 04 05 CODE & STANDARDS

More information

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance

N2 Blanketing Valve DST100 / DST200 TYPE INSTRUCTION MANUAL CONTENTS K.S.P.C. General Description Operation. Installation Maintenance DST100 / DST200 TYPE N2 Blanketing Valve INSTRUCTION MANUAL CONTENTS General Description Operation Installation Maintenance K.S.P.C 488-1 Wolha-ro, Tongjin-eup, Gimpo-si, Gyeonggi-Do, Korea Tel : +82-31-998-3825~7

More information

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/2) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 02 PROJECT : QUANTITY : 03 LOCATION : SERVICE : FOAM SYSTEM 04 05 CODE & STANDARDS

More information

FILTER BYPASS CONTROL

FILTER BYPASS CONTROL Differential Control Valve Series 110 The Series 110 Differential Control Valve is designed to accurately control the pressure difference between any two points. In some systems this means the valve remains

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic

More information

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912 Water VAG DUOJET Automatic Air Valve Single-chamber type Product characteristics and benefits Resilient seated With flange end acc. to EN 1092-2 Single chamber air valve in compact design Very high discharge

More information

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator January 2009 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator Introduction The Type 310A pilot-operated high-pressure regulator (Figure 1) is used where high capacity

More information

Smooth Vent Valve XVD. Series

Smooth Vent Valve XVD. Series Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

200A Series ELECTRONIC LEVEL TRANSMITTER

200A Series ELECTRONIC LEVEL TRANSMITTER MARINE - WATER AND PROCESS INDUSTRIES LIQUID LEVEL AND CONTENTS APPLICATIONS HYDROSTATIC OPERATION 200A Series ELECTRONIC LEVEL TRANSMITTER INTRINSICALLY SUBMERSIBLE - SCREWED MARINE SAFE FLANGED - HYGIENIC

More information

Pressure Equalising Valves Model , for Differential Pressure Gauges

Pressure Equalising Valves Model , for Differential Pressure Gauges Accessories Pressure Equalising Valves Model 910.25, for Differential Pressure Gauges WIKA Data Sheet AC 09.11 Applications T Isolating, pressure equalising as well as purging and air bleeding valves to

More information

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

1805 Series Relief Valves

1805 Series Relief Valves October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications

More information

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases

Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Glass tube flowmeters Series 2000 Variable area flowmeter for low flows of liquids and gases Short mounting length and compact construction, especially indicated for control panels Easy installation. No

More information

Air preparation units

Air preparation units Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 44, 45, 48 52 6 unit two piece 44, 45, 48 52 6 Filter-regulator 44, 45, 48 53 6 Filter-water-separator

More information

Variable Area Flow Meters

Variable Area Flow Meters Variable Area Flow Meters Over sixty years of variable area meter expertise Brooks started designing and manufacturing variable area (VA) meters, also referred to as rotameters, in 1946. Now, with more

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Smooth Vent Valve. XVD Series

Smooth Vent Valve. XVD Series Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

RR 16 Commercial & Industrial Regulator

RR 16 Commercial & Industrial Regulator RR 16 Commercial & Industrial Regulator The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations where accurate

More information

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE MAKING MODERN LIVING POSSIBLE Data sheet Water valve Type WVO Water valve type WVO is used for regulating the flow of water in refrigeration plant with water-cooled condensers. The water valve gives modulating

More information

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 /

Purgemaster Series 10A6100 SNAP-IN. Instruction Bulletin Replaceable Parts List. D184B003U35 Rev. 01 / SNAP-IN Purgemaster Series 0A600 Instruction Bulletin Replaceable Parts List D84B003U35 Rev. 0 / 03.200 You have purchased a high quality, modern instrument from ABB Automation Products. We thank you for

More information

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order Process Pump /5 Series Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted areas.

More information

Industrial Filter. FGD series

Industrial Filter. FGD series 1/8 P r o d u c t N a m e Industrial Filter Model/ Series/ Product Number FGD series FGD - - - Material Accessory Element length Element Port size Contents 2/8 Safety Instructions 3 Safety Instructions

More information

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Description Supply pressure Pressure range Connection Device Page max. bar bar thread Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

2 I All-Flo Pump Co.

2 I All-Flo Pump Co. 2 I All-Flo Pump Co. 3I All-Flo Pump Co. Model Designation Matrix PRODUCT SERIES PUMP SIZE FLUID CONNECTI INTERM INNER CHAM ON TYPE FLUID C HAMBER MANIFOLDS EDI A TE/ BER O-RINGS VAL VE SEAT VALVE/BAL

More information

Foam Chamber Model-FC

Foam Chamber Model-FC Tel: 00-44-8450751042 Fax: 00-44-8450751043 Email: info@fireguard-uk.com 2nd FLOOR 145-157 ST.JOHNS STREET LONDON EC1V 4PY UNITED KINGDOM Foam Chamber Model-FC TECHNICAL DATA : MODEL SIZE inlet WORKING

More information

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1 Pressure reducing valve, direct operated, type DR 5 DP Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pressure reducing valve, direct operated, type DR 5 DP Size 5 up to 31.5MPa up to

More information

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids

R300 HELYON. Brass high pressure regulator, for compressed air, gas and liquids HELYON 5 Chemin du Jubin 69570 DARDILLY Tél. +33 (0)4 72 52 16 70 - Fax +33 (0)4 72 52 16 71 R300 Brass high pressure regulator, for compressed air, gas and liquids FEATURES Pressure regulator for inlet

More information

Rev. A Jul 07 Part # SS VD510-SS INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510-SS INSTRUCTION MANUAL

Rev. A Jul 07 Part # SS VD510-SS INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510-SS INSTRUCTION MANUAL DISPENSING VALVE MODEL VD510-SS INSTRUCTION MANUAL CONTENTS 1 Introduction page 3 2 Specifications page 3 3 Part Description page 4 4 Operation Principles page 5 5 Operating Procedure page 6 5-1 Setup

More information

Nikuni KTM Series Pumps

Nikuni KTM Series Pumps Nikuni KTM Series Pumps ( Micro Bubble Generator for DAF System ) Client : Project : Model : KTM2N- (SS34 Material) Doc. No. : Date : Revision No. : Japan Headquarters : 843-5, Kuji, Takatsu-Ku, Kawasaki-Shi,

More information

Liquid Level Indicating Controller

Liquid Level Indicating Controller OVERVIEW KF Series Liquid Level Indicating Controller The KF Series instruments are field-mounted type pnematic indicating controllers which are used to measure and control various types of process variables

More information

Pump Relief, Pressure Tank/

Pump Relief, Pressure Tank/ CIRCUIT VALVE ( PRIMARY PRESSURE REGULATING VALVE ) (for Water Air or Oil) Pump Relief, Pressure Tank/ Piping etc. High-performance relief valve that can respond to load change, relieve excessive pressure,

More information

High precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment

High precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment Fluid dose dispensing valve High precision dispensing valve that is an uncompromising response to the need for sophisticated dispensing equipment Provides the high productivity, stability, reliability,

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

Variable area flowmeter F VA 250

Variable area flowmeter F VA 250 Fig. variable area flow meter pplication The V 5 variable area flowmeters with a standard length of 5 mm (9.84 inch) and a completely metal design can be used to measure many different types of liquids

More information

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters Data Sheet DS/NDA-EN Rev. H Model NDA Differential pressure transmitter Deltapi N Series A complete range of pneumatic pressure transmitters Introduction The blind type differential pressure transmitter

More information

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012

V DFX Series. Direct-Operated Tank Blanketing Regulator Manual D103808X012 V2015.2 DFX Series Direct-Operated Tank Blanketing Regulator Manual D103808X012 Contents 1. Introduction... 3 2. Specifications... 3 3. Features... 3 4. Dimensions... 4 5. Principle of Operation... 4 6.

More information

VESSELS. DIAPHRAGM OR BLADDER TANKS For expansion and pressure boosting applications. Temperature range : -10 to C* Operating pressure :

VESSELS. DIAPHRAGM OR BLADDER TANKS For expansion and pressure boosting applications. Temperature range : -10 to C* Operating pressure : operating limits Temperature range : -10 to + C* Operating pressure : to 20 bar* * according to models. VESSES IAPHRAGM OR BAER TANKS For expansion and pressure boosting applications AdVANTAGES APPICATIONS

More information

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC

Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC Flow measurement Orifice plate, model FLC-OP Orifice flange, model FLC-FL Annular chamber, model FLC-AC WIKA data sheet FL 10.01 Applications Power generation Oil production and refining Water treatment

More information

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø Series RM/ End lock RME Port Plug End block End block type Mounting position L Left side R Right side L side end block 0. L VVQ0000 Single unit regulator / Port plug for regulator block ø0 0 Options Note

More information

Tank Blanketing Pressure Regulators RHPS Series

Tank Blanketing Pressure Regulators RHPS Series www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22

More information