Manual retractable fitting with safe-to-operate rotary drive
|
|
- Louise Harvey
- 5 years ago
- Views:
Transcription
1 Manual Retractable Fittings SensoGate W M Manual retractable fitting with safe-to-operate rotary drive Revolutionary operation The SensoGate W M has a manual rotary drive, which enables the fitting to be operated up to a counter pressure of 45 psi ( bar) and this in less than two rotations. Regardless of how unfavorable the angle or the operating height at which the fitting is installed. Little rotary force is required and is easily applied manually. This is not possible with the sliding motion of conventional retractable fittings. Maximum process safety The configuration of the O-rings means that there is never any connection between the drain opening of the cleaning chamber and the process, even during inward and outward movement of the sensor. For maximum process safety, the sensor can only be removed in the service position. utomatic insertion protection reliably blocks the movement of the fitting and prevents extension into the process position without a sensor. Facts ompact, buildup resistant design Low maintenance Simple replacement of seals due to divided calibration/cleaning chamber Increased service life and reduced seal wear TEX approval II G c II for the complete fitting Low cost, simple installation, operation, and maintenance SensoLock for high operational safety Integrated limit switches Fast and easy replacement of calibration chamber and insertion tube ll maintenance can be performed on site yclone cleaning effect Standard sensor length (5 mm) even for large immersion depths Multiple process connections available Flange version with scraping ring Modular design allows specific replacement of the process-wetted materials: PEEK, PVF, PP, 6 SS, Hastelloy Plastic versions with high pressure and temperature resistance due to carbonfiber-reinforced plastics Special version for sensors with pressurized liquid electrolyte 56
2 For up-to-date information, please visit Specifications Permissible process pressure and temperature during movement Process material 6 SS/ 45 psi ( bar) (at ( 84 F) 4 )) Hastelloy Process material PEEK H Process material PVF H Process material PEEK / PVF Process material PP Permissible process pressure and temperature, in service position mbient temperature 45 psi ( bar) (at ( 84 F) 4 )) 45 psi ( bar) ( 48 F ( )), 6 bar (84 F (4 )) min 87 psi (6 bar) ( 4 F ( 4 )), falling linearly to 9 psi ( bar) (48 F ( )) 87 psi (6 bar) (4 86 F (5 )), falling linearly to 4.5 psi ( bar) (76 F (8 )) psi (6 bar) (at 4 F ( 4 )), PP bars (at 5 ) 4 58 F ( 7 ) Ingress protection IP 66 Housing material Permissible pressure for probe control s With gel electrolyte With liquid electrolyte Stainless steel /PP or stainless steel/peek 58 psi (4 7 bar) Ø mm, length 5 mm with temp detector, Pg.5 thread Ø mm, length 5 mm with temp detector Process connections Flanges, IN EN 9- N Flanges, NSI 6.5 /; to ; Threaded ; NPT airy pipe, IN 85 N 5 Ingold socket, 5 mm G /4; onnections Rinse and calibration media (optional) Outlet (optional) For pressurized sensors Immersion depths/ Installation dimensions Process-wetted materials 5 mm for Knick RF/X internal thread G /8;, hose coupling G /8;-N 4/6 outlet hose, NW 8 EPM m hose connection NW 6, pressure in sensor chamber.5 bar above process pressure (max. 7 bar) see dimensional drawings see order code 57
3 Manual Retractable Fittings SensoGate W M for process applications Product Line Order No. Process sensor lock-gate, pneumatic W M / _ Explosion protection for hazardous area Zone without X N solid electrolyte liquid electrolyte (pressurization possible) Gasket material elastomeric ring set, FKM (Viton) elastomeric ring set, EPM elastomeric ring set E, EPM F elastomeric ring set K, FFKM, compl. (Kalrez) E K Process-wetted materials*} 6 SS /6 SS /6 SS Hastelloy / Hastelloy / Hastelloy PEEK / PEEK / PEEK PVF / PVF / PVF PEEK H / PEEK H / PEEK H PVF H / PVF H / PVF H PP reinforced E F P Process adaptation flange, steel, 6 SS, N flange, steel, 6 SS, N 4 flange, steel, 6 SS, N 5 flange, steel, 6 SS, N 65 flange, steel, 6 SS, N 8!} flange, steel, 6 SS, N!} dairy pipe, N 5 dairy pipe, N 65 dairy pipe, N 8 dairy pipe, N flange, NSI 6 SS, /; flange, NSI 6 SS, ; flange, NSI 6 SS, /; flange, NSI 6 SS, ;!} 4 4 Immersion depth Ingold socket, 5 mm H G /4; for RF /xxxxx K NPT " (male) N short long Electrical limit signal with without Rinse-medium connection G /8; complete with outlet hose ( m) G /8; complete with outlet hose ( m), inlet G /8; G /8; complete with outlet hose ( m), inlet G /8; and inlet hose (5 m) complete with coupling nut Housing material stainless steel / PP (< 6 bars operating pressure) stainless steel / PEEK (< bars operating pressure) Special variant without equipped with special grease (provided by customer) with scraper ring, reinforced version, PTFE/PEEK (ZU 76) reduced stroke (shortened immersion depth) 4 58 * ) Material combinations: Process-wetted part of calibration chamber/rinse-wetted part of calibration chamber/immersion tube ) With the lower calibration chamber made of plastic, you require one of the following flange protectors: ZU 755, ZU 756, ZU 757, ZU 758
4 For up-to-date information, please visit ccessories Order No. Service set basic equipment ZU 68 maintenance, repair, retrofit ZU 74 calibration chamber ZU 754 mounting wrench, 9 mm ZU 647 Mounting aid for x.5 O-rings ZU 747 for scraper ring ZU 746 ellows version for liquid-electrolyte sensors ZU 79 Protective cap version for sensors with polymeric electrolyte ZU 759 Scraper ring reinforced version, PTFE/PEEK ZU 76 Material ertificate. ZU 78 ir supply for pressurized sensors, 7 58 psi (.5 4 bar) ZU 67/ for pressurized sensors, 4.5 psi ( 7 bar) ZU 67/ Hose m (extension for ZU 67) ZU 7 Flange protectors PEEK / FFKM N 8 ZU 755 PEEK / FFKM N ZU 756 PVF / FFKM N 8 ZU 757 PVF / FFKM N ZU 758 Weld-in socket, beveled 5, PP, length 6 mm Safety weld-in socket, straight, 4 mm ZU 8 for tank wall ZU 77 for pipe, N 5 ZU 77/N5 for pipe, N 65 for pipe, N 8 for pipe, N ZU 77/N65 ZU 77/N8 ZU 77/N Safety weld-in socket, beveled 5, 4 mm for tank wall ZU 78 for pipe, N 5 ZU 78/N5 for pipe, N 65 for pipe, N 8 for pipe, N ZU 78/N65 ZU 78/N8 ZU 78/N for tank wall, Hastelloy ZU 78/ Retainer clamp for 5-mm socket ZU 88 59
5 Manual Retractable Fittings SensoGate W M for process applications Gaskets Set ontact (process/rinse medium) Order No. Flange or dairy pipe / / / / E/ E/ K/ K/ Ingold socket H / / FKM: Viton FFKM: Kalrez, hemraz, Perlast / / E/ E/ K/ K/ FKM FKM / FKM EPM EPM / EPM EPM F EPM F / EPM FFKM FFKM / FFKM FKM FKM / FKM EPM EPM / EPM EPM F EPM F / EPM FFKM FFKM / FFKM ZU 689/ ZU 89 ZU 69/ ZU 8 ZU 69/ ZU 8 ZU 69/ ZU 8 ZU 69/ ZU 8 ZU 694/ ZU 84 ZU 696/ ZU 85 ZU 695/ ZU 86 Spare Parts Order No. Immersion tube, short 6 SS ZU 7 Hastelloy ZU 85 PEEK ZU 74 PVF ZU 76 PP ZU 85 Immersion tube, long 6 SS ZU 7 Hastelloy ZU 854 PEEK ZU 75 PVF ZU 77 PP ZU 86 6
6 For up-to-date information, please visit imensional rawings Installation dimensions for SensoGate W M with short immersion depth for sensors with gel electrolyte Installation dimensions for SensoGate W M with long immersion depth for sensors with gel electrolyte Installation dimensions for SensoGate W M for sensors with liquid electrolyte Pg.5 Pg.5 5 mm pprox. 5 mm clearance for sensor installation 7 5 mm Ø pprox. 5 mm clearance for sensor installation 76 Ø pprox. 855 mm clearance for sensor installation 5 mm Ø SensoGate W M Process adaptation for flange, N N NSI 6 SS, /; ;, short and long immersion depth (I) SensoGate W M Process adaption for 5 mm Ingold socket, short and long immersion depth (I) SensoGate W M Process adaptation for dairy pipe, IN 85 N 5 N, short and long immersion depth (I) 65 (short I) (long I) 88 (short I) 4 (long I) 7 (short I) 6 (long I) (short I) 49 (long I) 65 (short I) (long I) 88 (short I) 4 (long I) 6
Pneumatic retractable fitting for simple commercially available control units or process applications
Pneumatic Retractable Fittings hem Energy Pharm Food Water SensoGate W 3 Pneumatic retractable fitting for simple commercially available control units or process applications Variable and reasonably priced
More informationPneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems
Pneumatic Retractable Fittings SensoGate WA 3 Pneumatic retractable fitting for use with Unical 9 and Uniclean 9 automated control systems Easy installation SensoGate WA 3 offers genuine plug & play. The
More informationSanitary pneumatic retractable fitting for use with Unical 9000 and Uniclean 900 automated control systems
Pneumatic Retractable Fittings SensoGate W 3 H Sanitary pneumatic retractable fitting for use with Unical 9 and Uniclean 9 automated control systems Easy installation offers genuine plug & play. The central
More informationPneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas
Pneumatic Retractable Fittings Pharm Food SensoGate W 3 H Pneumatic sensor lock-gate for demanding fully automated process applications in hygienic areas Easy installation and clear hose connections offers
More informationArmatures for analytical probes
Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type
More informationTechnical Information Cleanfit CUA451
TI00369C/07/EN/13.13 71238305 Products Solutions Services Technical Information Cleanfit CUA451 Manually operated retractable assembly for water, wastewater and process media Application Drinking water
More informationph measuring system for hygienic process applications
ph measuring system for hygienic process applications Sterile design, CIP-compatible, in-line sterilizable Extremely robust and unbreakable construction Extremely long service life Long calibration intervals
More informationKDV HIGH ACCURACY GLASS TUBE ROTAMETER
KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design
More informationExpansion Thermometers Stainless Steel Series, Model 70
Mechanical Temperature Measurement Expansion Thermometers Stainless Steel Series, Model 70 WIKA Data Sheet TM 81.01 Applications General-purpose temperature measuring instruments for gaseous, liquid and
More informationOPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER
OPERATING MANUAL CHEMTRAC 840M MANUAL RETRACTABLE PROCESS HOLDER Table of contents 1 Security and safety measures... 5 1.1 General safety instructions... 5 1.2 Intended use... 5 1.3 Danger zones and residual
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option
ABB MEASUREMENT & ANALYTICS DATA SHEET AP100 ph/redox (ORP) cartridge sensors with water-wash option 2 AP100 P H / R EDOX ( ORP ) CART RI D GE SE NSORS WITH WATE R-WASH OPTION DS/AP100-E N RE V. K Measurement
More informationVSR modulating valves with membrane actuator
Modulating valves are used in process technology to control process parameters such as temperature, pressure or flow when handling liquid and gaseous media. uth's team of design and process engineers have
More informationKDV HIGH ACCURACY GLASS TUBE ROTAMETER
KDV HIGH ACCURACY GLASS TUBE ROTAMETER Flow Pressure Level Temperature measurement monitoring control S2 Industrial and Sanitary Designs Body Sizes 1/2 Through 2 Reliable, Time Proven Glass Tube Design
More informationNeotecha SAPRO - Tank Valve Type ST for aseptic sampling with bottles Installation, Operation and Maintenance Instruction
7 Before installation these instructions must be fully read and understood 1.4 Illegal technical changes It is illegal to do mechanical changes of the design of the Sapro tank valve, or to use parts of
More informationNeotecha SAPRO - Aseptic sampling valve SV Installation, operation and maintenance instructions
Before installation these instructions must be fully read and understood 2 Safety Please read these instructions carefully. 2.1 General danger potential Not paying attention to this instruction Incautious
More informationSupplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968
Supplementary instructions Rod and cable components for VEGAFEX series 80 Document ID: 44968 Contents Contents 1 Product description 1.1 Extensions... 3 2 Mounting 2.1 General instructions... 6 2.2 Rod
More informationATM/GR. Electronic pressure switches CUSTOMER BENEFITS
Electronic pressure switches ATM/GR CUSTOMER BENEFITS Pressure sensor with integrated switching contacts Modular sensor structure (any process and electrical connections can be combined) Manual readjustment
More informationTest pumps. Pressure sources. Good reasons for proper and reliable calibration
Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even
More informationTank Blanketing Pressure Regulators RHPS Series
www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22
More informationHydraulic comparison test pump Models CPP1000-X, CPP1600-X
Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance
More informationCorporation Stops Technical Bulletin
Corporation Stops Technical Bulletin Available in ½", ¾", 1", 1¼", 1½", 2" Sizes The information contained in this manual was current at the time of printing. The most current versions of all Hydro Instruments
More informationBall Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"
Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with
More informationCable Glands. Special Applications. RoHS Compliance. Plastic & Metal Cable Glands Adapters Reducers & Enlargers Grommets & Accessories
able Glands RoHS ompliance Plastic & Metal able Glands dapters Reducers & Enlargers Grommets & ccessories L File #: E363825 cable gland is a device that allows the user to pass a cable, wire or tube into
More informationRetractable Process Assembly
BA 223C/07/en/07.03 51517648 CleanFit P CPA 472 Retractable Process Assembly Operating Instructions Quality made by Endress+Hauser ISO 9001 CleanFit P CPA 472 Table of contents 1 Safety instructions..............
More informationMUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.
Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read
More informationINSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION
INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic
More informationDescription Supply pressure Pressure range Connection Device Page max. bar bar thread
Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4
More informationHydraulic hand spindle pump Models CPP1000-M, CPP1000-L
Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations
More informationInstruction Manual. PE-25/32/37 Tapping Machines. POLYTAPP Valves
Instruction Manual PE-25/32/37 Tapping Machines & POLYTAPP Valves Nov 2016, Revision 2 Document Number 3000111 2 M.T. Deason Company, Inc. PO Box 101807 Birmingham, AL 35210 Phone: 205 956 2266 Fax: 205
More informationInstruction presentation Special valves
Instruction presentation Special valves 1 Special Valves 2 Special Valves Index of contents 1. Overview special valves 2. Description Gauge Guard 3. Description Water Jet Pumps 4. Description Venting and
More informationUltrasonic. 58 Overview VEGASON 60 VEGASON 61, 62, 63
Ultrasonic 58 Overview VEGASON 60 VEGASON 61, 62, 63 57 Overview VEGASON Area of application The ultrasonic sensors of the VEGASON series are suitable for non-contact level measurement of liquids and bulk
More informationBall Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65
Data Sheet 819346-02 Issue Date: 05/17 Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300, 50, 65 UNA 45hl MAX, UNA 46hl MAX, UNA 46Ahl MAX UNA 45v MAX with cover for mounting electrode
More informationCost effective. Smooth. Reliable. LOG Internal Hole Gripper
LOG Cost effective. Smooth. Reliable. LOG Internal Hole Gripper Light gripper made of very resistant polyamide with closed diaphragm system Field of Application Particularly suited to highly dynamic applications
More informationFILTER TYPE PRESSURE SNUBBER
FILTER TYPE PRESSURE SNUBBER Pressure oscillations and other sudden pressure changes can affect the delicate mechanisms of a pressure gauge or pressure transmitter. This can result in either complete failure
More informationINDUSTRIAL EXCESS ESS FLOW VALVES
INDUSTRIAL EXCESS ESS FLOW VALVES H-911 SERIES FEATURES n Stainless Steel Construction n MAWP 6000 psi (413 bar) n MAWT 400 F (204 C) n Variable connection sizes (1/8 to 1/2'' & 6 to 12mm) n Cv = 0.5 ;
More informationHydrostatic. Continuous level measurement. Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 AL-EN
Hydrostatic Continuous level measurement 8 Overview Page 188 VEGAWELL 52 Page 190 VEGABAR 86, 87 Page 192 Accessory Page 196 187 Hydrostatic Level and pressure measurement Measuring principle The pressure
More informationMounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators
Supply Pressure Regulator Type 4708 Type 4708-5352 on Type 3730 Positioner Type 4708-52 with filter receptacle Type 4708-6252 on Type 3372 ctuator Fig. Supply pressure regulators Mounting and Operating
More informationHIGH-PRESSURE RELIEF VALVES
HIGH-PRESSURE RELIEF VALVES H-9HP SERIES FEATURES n St.St. 316 Construction n MAWT up to 6 psi n Set Pressure from 5 psig to 6 psig ( 3.5 to 4 bar) n Identifying colored springs for each pressure range
More informationInflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer
Inflatable Packer Single & Double Single & Double Packer Dimension Wireline Packer Water Testing Packer (WTP) Packer Packer Working Pressure & Depth Chart Packer Water Hand Pump Packer Air Driven Pump
More informationTWO POST RAM PACKAGE 5 GALLON READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.
OPERATOR S MANUAL TP0411G2XXXXXXXX INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE. RELEASED: 2-15-10 INCLUDE MANUALS: AF0411GXXXXXX-XX-X Two-Ball Pump (97999-1496), 66731-X Follower Assembly (pn REVISED:
More informationPressure Dump Valve Service Kit for Series 2300 Units
Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit
More informationTHE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401
THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More informationDM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationMounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type
Type 4708 Supply Pressure Regulators Translation of original instructions Type 4708-53 Type 4708-64 Type 4708-12 Mounting and Operating Instructions Edition March 2018 Note on these mounting and operating
More informationHOVAP SERIES 9600 BASICFLOW PROCESS VALVES INSTRUCTION MANUAL
1 CONTENTS 2 Introduction 2 2.1 Valve use 2 2.2 Application area 2 2.3 Incorrect use 2 3 Safety 2 4 Transport and storage 2 5 Installation instructions 2 5.1 Mounting 2 5.2 Installation into pipework 2
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More informationInstructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO
Instructions for Use Plug connection for medical gas and vacuum acc. to DIN 13260-2 / 2004 DIN EN ISO 9170-1 Table of Contents Page 1. MANUFACTURER S DATA... 3 2. INTRODUCTION... 4 3. APPLICATION... 5
More informationBray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual
Bray/ VAAS Knife Gate Valve 770/780 Series Operations and Maintenance Manual Table of Contents Definition of Terms 1 Safety Instructions 1 Introduction 2 Unpacking 2 Storage 2 Installation 2 Commissioning
More informationETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationPressure Transmitter P41
SENSORS FOR AND BIOPHARMA. Product Information P41 Pressure Transmitter P41 Application/Specified usage Pressure measurement in pipes and tanks For process temperatures up to 250 C (428 F) with optional
More informationB84G - Excelon Plus Modular System General purpose filter/regulator
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant
More informationSchroeder Check Test Point System
Perforated polyamide / kevlar hose, 2 mm ID, 5 mm OD, plastic dust cap. L in (mm) P (max) psi (bar) 6 (150) 10,000 (680) 12 (300) 10,000 (680) 24 (610) 10,000 (680) 36 (915) 10,000 (680) 48 (1220) 10,000
More informationSITRANS P measuring instruments for pressure
Remote seals for transmitters and pressure gauges Technical description Overview In many cases the pressure transmitter and the measured medium have to be physically separated. It is then necessary to
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More information1/2 to 2-1/2 NPT; 0 to 230 PSI Advantages / Benefits
/-Way Angle-Seat Valve Type 000 to - NPT; 0 to 30 Advantages / Benefits Spring return closed or open, double-acting Materials: bronze, stainless steel High flow rate Self-adjusting packing glands with
More informationTECHNICAL BULLETIN. Sigma-Aldrich Pure-Pac II System. Technical Bulletin AL-236
Sigma-Aldrich Pure-Pac II System Technical Bulletin AL-236 TECHNICAL BULLETIN Product The Sigma-Aldrich Pure-Pac II packaging/dispensing system provides a convenient method for storing and dispensing laboratory
More informationOxygen Measurement Systems High Reliability and Wide Application Coverage
Introduction High Process Efficiency Under Any Condition Oxygen Measurement Systems High Reliability and Wide Application Coverage METTLER TOLEDO provides sensors to measure dissolved oxygen (DO) in demanding
More informationPVC FASTTAP SADDLES for IPS Mains. Main Size OUTLET 1 FPT 3/4 CTS (7/8 OD) COMPRESSION 1 CTS (1 1/8 OD) COMPRESSION 3/4 IPS COMPRESSION
PVC FASTTAP SADDLES PVC FASTTAP SADDLES for IPS Mains THE ULTIMATE CONNECTION OUTLET 3/4 IPS FEMALE SLIP OR 1 IPS MALE SLIP SOLVENT WELD 1 IPS FEMALE SLIP SOLVENT WELD 3/4 MPT 1 MPT 3/4 FPT MAIN 13/16
More informationVCO O-ring Face Se al Fit tings
www.swagelok.com O-ring Face Se al Fit tings /8 to sizes 36 or 36L stainless steel, NPT, S thread, and weld connections 2 O-ring Face Seal Fittings ontents Features........................................
More informationTechnical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3
Technical data sheet R2.. Open-close ball valves, 2-way, with internal thread for open and closed cold and warm water systems for shut-off functions on the water side and 2-point controls in air-handling
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationR84G - Excelon Plus Modular System Pressure regulators
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Easy to read flush mounted integrated pressure gauge as
More informationL21S/SR/ST Glass Level Gauges
L21S/SR/ST Glass Level Gauges Doc. no.: 150, en_cat_l21s/sr/st, 12/2014 Type of code Example: L21ST/1450/AANSI 3/4 150Lb RF/Large chamber Code 1 Basic type L21 2 Type of gauge S Tubular level gauge SR
More informationOverview. VARICOVER product recovery systems. Special features. Recover the value, reduce the waste! Design with no dead-zones.
Overview Recover the value, reduce the waste! Special features Design with no dead-zones CIP/SIP-able Reduced product loss Reduced cleaning media and water consumption Reduced waste water load Reduced
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulators used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to. bar ( to 4 psi). to bar (8 to 9 psi)
More informationATS430 turbidity sensor Retractable insertion assembly
A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion
More informationOperating instructions - Translation of the original -
Operating instructions - Translation of the original - Overflow valves Typ 5076 DN 10 - DN100 KIESELMANN GmbH Paul-Kieselmann-Str.4-10 D - 75438 Knittlingen +49 (0) 7043 371-0 Fax: +49 (0) 7043 371-125
More informationSITRANS P measuring instruments for pressure
SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and
More informationMounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity
Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating
More informationPneumatic Powered - Plunger Pumps
Models 42/62/82 D Series P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pumps Suggested Installation & Operating Instructions
More informationRobolux Multiway Multiport Diaphragm Valve, standard product range
Robolux Multiway Multiport iaphragm Valve, standard product range Increased process efficiency Reduced installation costs Reduced number of valves and welds Zero dead volume and no contamination Type 2035
More informationType 4708 Supply Pressure Regulator
Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to
More informationMagnetic Level Gauges
Bulletin B 03 04 Magnetic Level Gauges Remote Reading Systems Magnetic Level Switches Magnetic level gauges OPERATING PRINCIPLE The operation of the magnetic level gauge is based on some elementary physical
More informationshutoff valves 900 Series psig Manual Shutoff Valves
0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on
More informationCompany Profile.. About Sammi Machinery
Company Profile.. About Sammi Machinery What is Line Blind Valve? Line blinding has been used to pipe lines in various indutries wherever either positive shut-off is most concerned or full flow should
More informationFIELD DEVICES ANALYTICAL Product Specifications
FIELD DEVICES ANALYTICAL Product Specifications PSS 6-1C6 A EP462 Series ph Sensors - Twist-Lock Mount OVERVIEW The EP462 Series is a family of twist-lock style combination ph sensors designed for quick
More informationPressure Reducing Valve DMV 755
Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to
More informationBeamex PG PRESSURE GENERATORS. Beamex PGM PGV PGC PGHH PGPH PGL
Beamex PG PRESSURE GENERATORS 97 Beamex PGM PGV PGC PGHH PGPH PGL Beamex PG pressure generators are portable hand-operated pressure generators and ultimate field calibration pumps 98 Calibration pumps
More informationHydraulic hand test pump Models CPP700-H and CPP1000-H
Calibration technology Hydraulic hand test pump Models CPP700-H and CPP1000-H WIKA data sheet CT 91.07 for further approvals see page 2 Applications Simple test pressure generation on site, in the laboratory
More informationCPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846
CPVC Transition Fittings - Female Adapter STD4703BTLF12 1/2 CPVC X 1/2 FIP 25 250 CPVC Transition Fittings - Female Adapter STD4703BTLF34 3/4 CPVC X 3/4 FIP 25 250 CPVC Transition Fittings - Female Adapter
More informationUltrasonic. Continuous level measurement. Overview Page 64 VEGASON series 60 Page 66 AL-EN
Ultrasonic Continuous level measurement Overview Page 64 VEGASON series 60 Page 66 6 VEGASON Non-contact measurement with ultrasonics Measuring principle Short ultrasonic pulses in the range of 5 to 70
More informationMyControl Bathing System Signature Series
MyControl Bathing System Signature Series Touch Assist Touch Pad and CM Technologies Seal Pressure Regulation Instructions Acceptable seal inflation pressure setting must be varified, and adjusted if necessary,
More informationType Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN
Type 4708-45 Pressure Regulator for increased air capacity Fig. 1: Type 4708-45 Pressure Regulator Mounting and Operating Instructions EB 8546-1 EN Edition March 2010 Definition of the signal words used
More informationHow to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø
Series RM/ End lock RME Port Plug End block End block type Mounting position L Left side R Right side L side end block 0. L VVQ0000 Single unit regulator / Port plug for regulator block ø0 0 Options Note
More informationB-Too Drilling and Tapping Machine
Material Specifications Powered by hand or with Ridgid 690 (TM-29) High strength, modular aluminum and steel components Inserts any 3 /4" to 1" corporation stop under pressure Extracts threaded corporation
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More informationCLARK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe Sizes, Rugged Molded PPA Construction
www.clarksol.com LRK 200 Series Vortex Flow Transmitter Frequency Output, 1/4 to 1.0 Pipe s, Rugged Molded PP onstruction DESRIPTION The series 200 vortex flow transmitters are designed with equipment
More informationCoiling Tube with Twist-Proof Fitting
http://www.pisco.co.jp FITTING CONTROLLER VALVE TUBE MAKE-TO-ORDER PRODUCTS Push-In Fitting Type Anti-Twisting Coiling Tube for Air Tool Coiling Tube with Twist-Proof Fitting 306 Avoid Twisted Tube Problem
More informationContinental Industries STEEL SERVICE TEES or FAX Visit
Continental Industries STEEL SERVICE TEES 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and
More informationPneumatic Gripping Modules. Pneumatic 2-Finger Radial Grippers
Pneumatic Gripping Modules Pneumatic 2-Finger Radial Grippers Pneumatic Gripping Modules Pneumatic 2-Finger Radial Grippers 2-FINGER RADIAL GRIPPERS Series Size Page Universal Grippers GWB 676 GWB 34 680
More informationDTG - LCD Digital Temperature Gauge USER MANUAL
DTG - LCD USER MANUAL Page 1 of 7 USERS GUIDE page 1. Description 3 2. Function 3 3. Safety Instruction 3 3.1. Safety Conventions 3 3.2. Proper Use 3 4. Installation 4 4.1. Unpacking 4 4.2. Storage 4 4.3.
More informationAluminium, white with black lettering. Bar. Option with unit bar/pa, bar/psi, kpa, MPa, psi
Ed.17.01 Application Industrial pressure gauge with liquid filling. Intented where pulsation or vibration exists. Suitable for media that will not attack copper alloy parts Design EN 837-1 Series Serie
More informationALF400 to 900, ALT-5/-9
uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa 0. MPa.0 MPa (Note
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationVarea-Meter Flowmeters. For Metering and Controlling Flows of Process Fluids
Varea-Meter Flowmeters For Metering and Controlling Flows of Process Fluids Product Descriptions Our broad line of rotametertype flowmeters provides reliable readout, transmission, and control of liquids
More informationStirred Reactors and Pressure Vessels
P a r r I n s t r u m e n t C o m p a n y Stirred Reactors and Pressure Vessels Designing and Building Quality Pressure Apparatus for Over 100 Years Bulletin 4500 Volume 12 Start Chapter Six This pdf is
More informationPilot valves for pilot operated servo valves
Data sheet Pilot valves for pilot operated servo valves The range of pilot valves consists of: Constant-pressure pilot valve, type CVP (LP) and CVP (HP) Differential-pressure pilot valve, type CVPP (LP)
More informationINDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES
INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts
More information