MDT Status: Installation and Commissioning

Size: px
Start display at page:

Download "MDT Status: Installation and Commissioning"

Transcription

1 MDT Status: Installation and Commissioning Missing 9 stations L. Pontecorvo

2 Outline Installation and infrastructure status Commissioning Status Sector Commissioning i strategyt Integration with other ATLAS sub-detectors Results from Toroid run in November 2

3 Installation and services 3

4 Installation and Positioning 673/682 installed: missing 6 sidea + 3 side C After installation on the rails must be positioned specs:~2mm; 2mrad Main limitations: Interference with other sub- systems services and access Very tricky: BIR/BIM in sectors 11 and 15 and BMS all sectors and BOL/BOS external chambers It goes very fast once we have access + OK from TC 575/682~84% of the barrel is positioned Gray: not installed Light green: installed Dark green: installed AND positioned 4

5 Cables and Gas All MDT optical and control cables (~200) from USA15 to barrel PP installed in All patch panels installed - All Alignment, - All CANBUS DCS cables - All MDT RO and TTC fibers All LV and HV cables installed All DCS daisy chain installed on positioned sectors Rack dressing for upper sectors well under way > 70 % of Optical patch cords installed 5

6 Gas system status All manifolds and valves installed 15 UX racks operational All (~300) pneumatic valves ok; All barrel racks equipped with zeolite filters Systematic leak tests of combined system using PVSS control: Connection of chambers to Leaks found in: BIS S2: two chambers manifold following chamber BIS S8: one chamber Repaired positioning BIS S10: five chambers BOL S1: not identified yet BOLS15 Repaired 6

7 Power supply: LV/HV In 2007 CAEN will deliver: 80% of RPC and barrel LVL1 PS (HV/LV) 80% of TGC 40% of the LV for MDT 25% of the HV for MDT-CSC MDT Commissioning issues: HV/LV boards for sectors 5 & 6 Available Need more boards for the commissioning of other sectors 7

8 Commissioning 8

9 USA15 - DCS and Alignment TTC Crates ready both for Barrel and End-Cap p( (E. Pasqualucci) All ROD-ROB fibers routed (Italian Techs) CANbus PS and DCS PCs for all Barrel Full Barrel alignment system HV-LV DCS-PCs for Barrel (also for RPCs) (P. Valente, G. Aielli) Sectors 5, 6, 3A & 4A RODS are available and cabled 9

10 Commissioning Strategy All stations arrived at ATLAS after cosmic ray certification and retested at SX1 (now dismissed) Due to late availability of services level-by-level strategy adopted in the pit Level I: fast test of station integrity: gas tightness, broken wires Level II: check basic functionalities with provisional services: DCS, FE elx. behavior, in some cases also noise runs Level III: check full functionality and sign-off of complete sectors done only when final services available MDT+RPC/LVL1: Full test up to cosmic ray run First determination of optimal working point Dead channels maps, After Level III Full SECTORS ready to be integrated in ATLAS: commissioning Phase II 10

11 MDT test up to Level II MDT: 216/630 tested Mainly Inner chamber difficult to access later (BIL and BIS) Up to now test done using provisional services Since January moved to final services sector 5 and 6 DONE with hfinal services Many problems found and fixed: mainly damaged components: ELMB, CSM, cables, fibers, 11

12 LVL III -Full Sectors commissioning schedule Constraints Possibility/Access to position stations Availability of services + CAEN Power supplies Strategy: start from top sectors Schedule Sector 5 and 6: April/May (Under way) Sectors: Month: June July Aug Sept Oct. Nov. PS schedule: October 07 ~80% of RPC/LVL1 and only 40% of fmdtlv expected: After sector 5/6 move around Jolly set of CAEN boards to commission all other sectors (depending on delivery from CAEN) Only part of the barrel integrated in ATLAS by fall

13 Phase II commissioning: Integration in ATLAS Integration of sector 13 in March combined ATLAS run: MDT: ROD-ROS readout HV/LV DCS integrated RPC/LVL1: VME readout muon trigger via MUTCPI-CTP Starting from June integrate sector 5A & 6A (after we have commissioned it): Use these sectors as benchmark for phase II to include all final features needed in ATLAS: DCS, DSS, chamber initialization, configuration DB, high level muon trigger, Data analisys 1 FULL CAEN PS set left on this sector Other sectors can be added later once are signed off depending on PS availability 13

14 MDT HV-LV DCS integration MDT HV-LV DCS succesfully integrated in Central DCS. 1 PC, 1 branch controller, 6 boards in 4 crates in UX15 Controlled from ATLAS Global Control Station Project almost completed still to be finalized: Archiving Configuration database Condition database INFN- University of Athens joint project 14

15 Results from Sector 13 cosmic ray test with Magnetic Field

16 Sector 13 run: set up Full weekend of data taking with 13 feet chambers during the Barrel Toroid test in November 13 Muon stations read-out BIL BML BOL Side A BOL 3 BIL 3 BIL 2 BML 3 BIL 1 η=0 BOF BOF BOF3 BOF1 LVL1 muon Trigger provided by 3 BML RPC/LVL1 and distributed via MUCTPI + CTP to muon system 16

17 Sector 13 data Sector 13 cosmic data used as benchmark to test commissioning procedures for sector sign-off MDT: Noise Dead channels Drift behavior Preliminary alignment RPC/LVL1: Noise Efficiency Working point optimization LVL1 timing Automatic tools to perform stations sign-off under preparation 17

18 MDT Inefficient tubes from chamber profile dead tubes Silvia Franchino (INFN Pavia) 18

19 MDT Noise rates Offline analysis per ogni tubo: t< t 0 Typical physical background in barrel ~10kHz GNAM result Online monitoring Silvia Franchino (INFN Pavia) 15 / 12 /

20 Impact of magnetic field on MDT drift B field expected to change drift-to to-radius relationship by Lorentz angle 20

21 Installation and Commissioning Coordination Overall coordination: F. Cerutti (INFN) & L. Pontecorvo (INFN) Run coordination: S. Vlachos (CERN) & D. Boscherini (INFN) MDT DCS: P.Valente (INFN) S. Zimmermann (Friburg) Gas MDT: T. Meyer (CERN) RPC DCS : G. Aielli (INFN) Gas RPC: R. De Asmundis (INFN) DAQ: E. Pasqualucci (INFN) Trigger: S. Veneziano (INFN) Service Installation: A. Lanza (INFN) 21

22 Conclusions Installation almost completed left over only due to interference with other detectors or unavailability of BOG chambers Services Installation: Cabling almost finished moving to rack dressing DCS, Alignment and DAQ systems well under way. Level III Sector commissioning starting now Very tight schedule and shortage of final power supply. Sectors will be available for integration in ATLAS Toroid test with cosmic rays showed good results 22

23 Richieste finanziarie Nuovo finanziamento per contratti con CAEN (Lettera Referee di A. Lanza): 55 KEuro per contratto per manutenzione software e aggiornamento firmaware 12.5 KEuro per Filtri i sul sistema di potenza Costruzioni apparati : Pavia 23

24 Back Up-Slides 24

25 Alignment Commissioning Systematic ti check of the 5817 optical lines has started: Difficulties: l mainly conflicts with gas-pipes, cable trays, support structure, Main i emphasis now on the 117 projective lines (backbone of the Barrel alignment) ~only 20 lines are working today Clashes with struts found in 28 cases 25

26 Cabling II Inner Layer Cabling of inner layer is mostly done 244 LV, 488 HV cables, 244 alignment, 448 pairs of optical patch cords in total All HV, LV alignment cables installed DCS daisy chain installed on positioned sectors Almost all of RO&TTC patch cords installed. Midlle Layer 178 LV, 356 HV, 178 alignment cables, 356 pairs of optical patch cords All LV and HV cables installed DCS Daisy chain installed on positioned sectors ~75% of RO&TTC patch cords installed, installation is ongoing 26

27 Cabling III Outer Layer Cabling of MDT outer layer is mostly done 202 LV, 404 HV cables, 202 alignment, 404 pairs of optical patch cords in total All HV, LV and alignment cables installed, few HV cables still to be re-arranged DCS Daisy chain installed on positioned sectors ~75% of RO&TTC patch cords installed, installation i is ongoing 27

28 Leak Test Systematic leak tests of combined system using PVSS control: Tested until now: (red = test currently underway) (315 in total) BIS: S2, S4, S6, S8, S10, S16 BMS: S2, S4, S6, S8, S10, S16 BML: S3, S5, S7, S13 BOL: S1, S3, S5, S7, S9, S11, S15 BOF/BOG: S14 Work still to start on : BIL, BIR, BIM, BOS, EIL4 Leaks found in: BIS S2: two chambers BIS S8: one chamber Repaired BIS S10: five chambers BOL S1: not identified yet BOLS15 Repaired All other leaks (mostly in plumbing) identified and corrected. Ongoing work: Connect remaining chambers (~33%) to valves (ongoing g - 3 months). Finish leak tests (synchronous with chamber connection) Repair work according to damage found. 28

29 Muon DAQ Integration Sector 13A + 2 chambers of sector 5 22 crates, 3MROD 11 MDT chamber 2 ROS, 3 s-link RPC SL board, 1 crate ROD emulator used TTC signals sent through ROD prototype Connected to ROS via Ethernet Muons + Calorimeters +CTP+MUCTPI partition built MDT online histogram viewed by OHP Connection to Data Quality desk 29

Status of MDT Production and Testing

Status of MDT Production and Testing Sandra Horvat Max-Planck-Institut für Physik Status of MDT Production and Testing September 13-19, 2003 // ATLAS Overview Week // Praha, Czech Republic Outline Introduction: MDT Chambers (Monitored Drift

More information

ATLAS RPC QA results at INFN Lecce

ATLAS RPC QA results at INFN Lecce ATLAS RPC QA results at INFN Lecce M. Bianco,, I. Borjanovic, G. Cataldi, A. Cazzato,, G. Chiodini, M.R. Coluccia,, P. Creti, E. Gorini,, F. Grancagnolo, R. Perrino, M. Primavera, S. Spagnolo,, G. Tassielli,,

More information

LS2 Activities for the ATLAS Gas Systems

LS2 Activities for the ATLAS Gas Systems EP-DT Detector Technologies LS2 Activities for the ATLAS Gas Systems On behalf of the Gas Team CERN ATLAS Gas System Status Meeting 5 Oct 2018 1 Outline ATLAS Gas Systems - Maintenance and Operation -

More information

Assembly and Testing of RPCs in Pakistan. Hafeez Hoorani National Centre for Physics

Assembly and Testing of RPCs in Pakistan. Hafeez Hoorani National Centre for Physics Assembly and Testing of RPCs in Pakistan Hafeez Hoorani National Centre for Physics 1 Layout Introduction RPCs in CMS RPC: From Lab to Detector Assembly Testing QA & QC Installation and Commissioning 2

More information

ISR workflow Tests status

ISR workflow Tests status ISR workflow Tests status CMS week September 05, DT session Jesús Puerta-Pelayo, News & status Surface installation for YB+2, YB+1 finished (only feet MB4 chambers missing, to be installed after cabling)

More information

EB/EE. Status: Recent Highlights Status: Interesting re-discovery Status: To-Do List Principal items. Preliminary Shutdown Schedule

EB/EE. Status: Recent Highlights Status: Interesting re-discovery Status: To-Do List Principal items. Preliminary Shutdown Schedule EB/EE Status & Plans Status: Recent Highlights Status: Interesting re-discovery Status: To-Do List Principal items EB/EE Plans for remainder of CRAFT Preliminary Shutdown Schedule 1 Recent Highlights 1)

More information

Assembly and measurements of a mechanical prototype of the BIS MDT chamber

Assembly and measurements of a mechanical prototype of the BIS MDT chamber ATLAS Internal Note MUON NO 243 9 June 1998 Assembly and measurements of a mechanical prototype of the BIS MDT chamber K. Ekonomou Physics Department, Aristotle University of Thessaloniki, Thessaloniki,

More information

Top Level of CSC DCS UI

Top Level of CSC DCS UI Top Level of CSC DCS UI - CSC normally in central DCS control -cdcs - Central DCS shifter monitors the CSC system, but doesn't take any action without consulting with the CSC shifter - CSC Shifter also

More information

Monitored Drift Tubes in ATLAS. Michele LIVAN 1. Dipartimento di Fisica Nucleare e Teorica, Universita di Pavia

Monitored Drift Tubes in ATLAS. Michele LIVAN 1. Dipartimento di Fisica Nucleare e Teorica, Universita di Pavia Monitored Drift Tubes in ATLAS Michele LIVAN 1 Dipartimento di Fisica Nucleare e Teorica, Universita di Pavia and INFN Sezione di Pavia, Pavia, Italy on behalf of the ATLAS Muon Group Abstract The precision

More information

Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer

Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer M. F. Vineyard, T. J. Carroll, and M. N. Lack Department of Physics University of Richmond, VA 23173 ABSTRACT The

More information

Long term stability tests of INO RPC prototypes

Long term stability tests of INO RPC prototypes Long term stability tests of INO RPC prototypes While the problem of sudden aging in the glass RPC prototypes is being investigated, a few RPCs of dimension 40 cm 30 cm were fabricated, using glass procured

More information

HV-LV, cabling & services

HV-LV, cabling & services HV-LV, cabling & services Introduction Detector description HV-LV requirements HV-LV systems description Cables and connectors DCS Conclusions F. Loddo 2, P. Paolucci 1, A. Ranieri 2 1) I.N.F.N. of Naples,

More information

arxiv: v1 [hep-ex] 18 Sep 2012

arxiv: v1 [hep-ex] 18 Sep 2012 Preprint typeset in JINST style - HYPER VERSION arxiv:109.3893v1 [hep-ex] 18 Sep 01 Performance of the Gas Gain Monitoring system of the CMS RPC muon detector and effective working point fine tuning S.

More information

Using PV Diagram Synchronized With the Valve Functioning to Increase the Efficiency on the Reciprocating Hermetic Compressors

Using PV Diagram Synchronized With the Valve Functioning to Increase the Efficiency on the Reciprocating Hermetic Compressors Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 21 Using PV Diagram Synchronized With the Valve Functioning to Increase the Efficiency on

More information

UK Opportunities in SiD Calorimetry

UK Opportunities in SiD Calorimetry UK Opportunities in SiD Calorimetry Paul Dauncey Imperial College London 7 Sept 2007 Paul Dauncey - Calorimetry 1 Overview SiD is designed for particle flow Calorimeters will be optimised using particle

More information

Analysis of RPC Performance with Different Gas Mixture

Analysis of RPC Performance with Different Gas Mixture Analysis of RPC Performance with Different Gas Mixture Cern Summer Student Programme Report Xing FAN xfan@icepp.s.u-tokyo.ac.jp 11/Sep/2015 Supervisor: Beatrice Mandelli (CERN PH-DT) 1 Introduction 1.1

More information

TEC Petal Integration & Lt Pilot Centres

TEC Petal Integration & Lt Pilot Centres TEC Petal Integration & Lt Pilot Centres Wim Beaumont 4, Guido Dirkes 1, Stefan Heier 1, Thomas Keutgen 3, Otilia Militaru 3, Benjamin Trocme 2, Valery Zhukov 1 1 Karlsruhe --- Institut fur Experimentelle

More information

LST Gas System. R. Messner May 2004 Readiness Review

LST Gas System. R. Messner May 2004 Readiness Review LST Gas System R. Messner May 2004 Readiness Review 1 Will cover a few of the items below Gas Mix the issue of what gas mixtures will be allowed in the LST system has been resolved FHA: O Neill, Budnick

More information

I sistemi di gas dei rivelatori. I sistemi di gas dei rivelatori. (DT e RPC) di muoni del barrel di CMS. Paolo Giacomelli - INFN Bologna

I sistemi di gas dei rivelatori. I sistemi di gas dei rivelatori. (DT e RPC) di muoni del barrel di CMS. Paolo Giacomelli - INFN Bologna I sistemi di gas dei rivelatori I sistemi di gas dei rivelatori di muoni del barrel di CMS (DT e RC) aolo Giacomelli - INFN Bologna Il rivelatore di muoni di CMS FORWARD CALORIMETER CMS A Compact Solenoidal

More information

Yoke Instrumentation: ILD Muon System / Tail Catcher. Valeri Saveliev IAM, RAS, Russia DESY, Germany 3 June, 2016

Yoke Instrumentation: ILD Muon System / Tail Catcher. Valeri Saveliev IAM, RAS, Russia DESY, Germany 3 June, 2016 Yoke Instrumentation: ILD Muon System / Tail Catcher Valeri Saveliev IAM, RAS, Russia DESY, Germany 3 June, 2016 ILD Muon System/Tail Catcher µ - µ + Events/0.2 [GeV] 150 + Zh µ µ - X 100 50 s = 250 GeV

More information

Status update of Beam pipe. S. Tanaka KEK

Status update of Beam pipe. S. Tanaka KEK Status update of Beam pipe S. Tanaka KEK 1 Gold peel-off problem: Phase 3 Beam pipe Gold peel-off has discovered after the sputtering. Considerable reason of this issue 1, The pipe is an double tube with

More information

The Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad

The Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad The Resistive Plate Chamber detectors at the Large Hadron Collider experiments Roberto Guida PH-DT-DI Danube School, September 8-13, 2014 Novi Sad Ionization chambers Ionizing particles are producing primary

More information

arxiv: v1 [physics.ins-det] 16 Aug 2014

arxiv: v1 [physics.ins-det] 16 Aug 2014 Preprint typeset in JINST style - HYPER VERSION RPC Gap Production and Performance for CMS RE4 Upgrade arxiv:1408.3720v1 [physics.ins-det] 16 Aug 2014 Sung Keun Park, Min Ho Kang and Kyong Sei Lee Korea

More information

The Transition Radiation Detector of the AMS-02 Experiment

The Transition Radiation Detector of the AMS-02 Experiment The Transition Radiation Detector of the AMS-02 Experiment Simonetta Gentile Università di Roma La Sapienza, INFN (Italy) for: RWTH Aachen, MIT, KNU Daegu, IEKP Karlsruhe, Universita La Sapienza, & INFN

More information

SiD VXD Geometry Update Su Dong SLAC

SiD VXD Geometry Update Su Dong SLAC SiD VXD Geometry Update Su Dong SLAC Aug/16/05 Su Dong SiD Vertexing: Snowmass 05 SiD trk+vtx 1 General Strategy The barrel + endcap layout is aimed a reducing the various effects at shallow entrance angles

More information

The Gas Team and the LHC gas systems: introduction. 11/10/2018 R. Guida on behalf of the Gas Team 1

The Gas Team and the LHC gas systems: introduction. 11/10/2018 R. Guida on behalf of the Gas Team 1 The Gas Team and the LHC gas systems: introduction 11/10/2018 R. Guida on behalf of the Gas Team 1 Outlook The Gas Team Experiment/detectors contact persons, egroups M&O Budget update Beyond M&O funds

More information

Residual Gas Analysis Systems for Industry

Residual Gas Analysis Systems for Industry HIDEN RC SYSTEMS QUADRUPOLE MASS SPECTROMETERS FOR RGA, GAS ANALYSIS AND PROCESS MONITORING The HAL RC systems are designed for RGA, gas analysis and process monitoring applications including leak detection,

More information

A Closer Look at Fiber Optic Cable Assemblies

A Closer Look at Fiber Optic Cable Assemblies A Closer Look at Fiber Optic Cable Assemblies Many network performance problems occurring at the physical layer are directly related to cable assembly quality. In fact, the overall performance and reliability

More information

Gas System Status Report

Gas System Status Report Gas System Status Report UGPS qualification Rome Control Electronics production schedule Gas circuit testing Software commands and safety Report from MIT B. Borgia TIM April 2006 Gas Circuit B. Borgia

More information

User s Guide. Vacuum Controller for liquid delivery systems

User s Guide. Vacuum Controller for liquid delivery systems Flow Control User s Guide Vacuum Controller for liquid delivery systems Precise Vacuum Control throughout the experiment Flow control Compatible with any perfusion system Ideal for Small Volume Delivery

More information

RPC CHARACTERIZATION AND TESTING ( by S. Mathimalar, INO Student)

RPC CHARACTERIZATION AND TESTING ( by S. Mathimalar, INO Student) RPC CHARACTERIZATION AND TESTING ( by S. Mathimalar, INO Student) Introduction: RPC are the Resistive Plate Chamber which consists of gas mixture in the gap between two glass plates (coated with pigment

More information

SiPM readout experience and prospects

SiPM readout experience and prospects SiPM readout experience and prospects Felix Sefkow DESY CALICE collaboration ALCPG workshop at Snowmass August 23, 2005 This talk SiPM mass production and tests Experience with multi-channel readout Future

More information

FUEL GAS FIRING CONTROL RJ (Dick) Perry Safety Systems Consultant 6 June 2016

FUEL GAS FIRING CONTROL RJ (Dick) Perry Safety Systems Consultant 6 June 2016 INTRODUCTION Fired equipment such as Heaters and Boilers, normally have to comply with either NFPA 85/86 or API 556 for North America and some other countries which apply such standards, or EN 746-2 for

More information

GIF++ A New Gamma Irradiation Facility

GIF++ A New Gamma Irradiation Facility EDMS No. Rev Validity 1280118 0.6 REFERENCE GIF++ Project 2013-01 CERN CH-1211 Geneve 23, Switzerland Date: 26/04/13 REQUIREMENTS GIF++ A New Gamma Irradiation Facility Abstract GIF++ (Gamma Irradiation

More information

PHENIX RPC in China. Xiaomei LI. Science and Technology on Nuclear Data Laboratory China Institute of Atomic Energy

PHENIX RPC in China. Xiaomei LI. Science and Technology on Nuclear Data Laboratory China Institute of Atomic Energy PHENIX RPC in China Xiaomei LI Science and Technology on Nuclear Data Laboratory China Institute of Atomic Energy 2010. 07 Outline 1.Motivation of the PHENIX Forward Upgrade 2.Study of PHENIX-RPC in China

More information

LNG TANDEM OFFLOADING A KEY ENABLING TECHNOLOGY TO MAKE LNG PRODUCTION OFFSHORE HAPPEN

LNG TANDEM OFFLOADING A KEY ENABLING TECHNOLOGY TO MAKE LNG PRODUCTION OFFSHORE HAPPEN LNG TANDEM OFFLOADING A KEY ENABLING TECHNOLOGY TO MAKE LNG PRODUCTION OFFSHORE HAPPEN Fabrice Dumortier 1, Jean-Pierre Queau 1, Jean-Robert Fournier 2 1. SBM Offshore 2. SBM Offshore Keywords: 1. LNG;

More information

SoLID Heavy Gas Cherenkov Update

SoLID Heavy Gas Cherenkov Update SoLID Heavy Gas Cherenkov Update Zhiwen Zhao, Chao Gu Garth Huber, Rory Evans SoLID Collaboration Meeting, March 5, 2017 HGC Prototyping Update 1Garth Huber, huberg@uregina.ca C$100k grants allow the U.Regina

More information

Police Pistol Combat Program Bulletin

Police Pistol Combat Program Bulletin NRA Law Enforcement s Police Pistol Combat Program Bulletin ISSUE: As produced from the factory is the pistol with the 5 inch barrel eligible for; Open Class PPC Matches Distinguished PPC Matches Stock

More information

Dry Gas Seal Rack CH-3185 Schmitten Tel Mail:

Dry Gas Seal Rack CH-3185 Schmitten Tel Mail: Dry Gas Seal Rack CH-3185 Schmitten Tel. +41 26 497 55 66 Mail: info@felcon.ch Usually, compressor modifications are carried out because of adaptations to new operating parameters. However, in cases of

More information

Installing ASI Umbilical Delivery Systems

Installing ASI Umbilical Delivery Systems Rev A 05 Nov 2015 Page 1 of 10 PURPOSE This guide provides an overview of tubing connections into an ASI wall-mounted Junction Box that has already been plumbed with a compressed air connection including

More information

Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment

Preliminary results of Resistive Plate Chambers operated with eco-friendly gas mixtures for application in the CMS experiment Prepared for submission to JINST 13 th workshop on resistive plate chambers and related detectors 22-26 february 2016 ghent university, belgium Preliminary results of Resistive Plate Chambers operated

More information

Product Overview. Product Description CHAPTER

Product Overview. Product Description CHAPTER CHAPTER 1 This chapter provides a functional overview of the Cisco Redundant Power System 2300 and covers these topics: Product Description, page 1-1 Features, page 1-3 Supported Devices, page 1-4 Deployment

More information

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010

LUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010 LUDLUM MODEL 239-1F FLOOR MONITOR Revised LUDLUM MEASUREMENTS, INC. 501 OAK ST., P.O. BOX 810 SWEETWATER, TX 79556 325/235-5494 FAX: 325/235-4672 STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants

More information

The TOTEM Gas System

The TOTEM Gas System Total Cross Section, Elastic Scattering and Diffraction Dissociation at the LHC EDMS No.: TOTEM-DI-ER-0001 TOTEM Experiment document No.: IN-2000/02 The TOTEM Gas System M. Bozzo (1), M. Castoldi (2),

More information

Development of small, easy to build and low gas consumming timing RPCs

Development of small, easy to build and low gas consumming timing RPCs Development of small, easy to build and low gas consumming timing RPCs LabCAF/Univ. de Santiago de Compostela, Spain. E-mail: miguel.morales@usc.es J.L. Rodríguez-Sánchez Department of Particle Phisics/Univ.

More information

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER

1 SE/P-02. Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER 1 SE/P-2 Experimental and Analytical Studies on Thermal-Hydraulic Performance of a Vacuum Vessel Pressure Suppression System in ITER K. Takase 1), H. Akimoto 1) 1) Japan Atomic Energy Research Institute,

More information

GLAST Large Area Telescope Monthly Mission Review

GLAST Large Area Telescope Monthly Mission Review GLAST Large Area Telescope Monthly Mission Review Gamma-ray Large Area Space Telescope LAT DAQ and Flight Software Status July 28, 2006 Gunther Haller Stanford Linear Accelerator Center Topics Hardware

More information

Finding Leak Testing Success Through Calibration and Validation. Paul Chamberlain President, CEO

Finding Leak Testing Success Through Calibration and Validation. Paul Chamberlain President, CEO Finding Leak Testing Success Through Calibration and Validation Paul Chamberlain President, CEO 2 Overview Confidence in Your Leak Test Results Sources of Uncertainty Pressure decay leak testing Helium

More information

OUS31. Technical Information

OUS31. Technical Information Technical Information OUS Turbidity sensor Installation and immersion sensor for drinking water and industrial water according to the 90 scattered light method Application All phases of drinking water

More information

Advanced Test Equipment Rentals ATEC (2832) OMS 600

Advanced Test Equipment Rentals ATEC (2832) OMS 600 Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) OMS 600 Continuous partial discharge monitoring system for power generators and electrical motors Condition monitoring

More information

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation.

Gas Check. Short testing time, with automatic start-up if no leakage was detected from previous operation. Quality Products at Competitive Prices Gas Check Automatic testing of the down-stream installation to check that all valves are closed and that pipework and fittings are gas tight before each system start-up.

More information

Status of the Hall B Gas Systems

Status of the Hall B Gas Systems Status of the Hall B Gas Systems George Jacobs, Physics DSG Group 9/6/2017 Hall B Gas Systems 1. DC Gas Mixing and Supply System 2. DC Gas Pressure Control and Safety System 3. HTCC CO 2 Purge Supply System

More information

The Discussion of this exercise covers the following points:

The Discussion of this exercise covers the following points: Exercise 5-3 Wet Reference Leg EXERCISE OBJECTIVE Learn to measure the level in a vessel using a wet reference leg. DISCUSSION OUTLINE The Discussion of this exercise covers the following points: Measuring

More information

Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers

Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers Mayda Velasco 1 Gianni Tassotto 3 on behalf of the SIC team P. Ball 2, A.Dabrowsky 1, G. Graham 2, C. Kendziora 3,

More information

Chamber Calibration Data

Chamber Calibration Data Statistical analysis of Chamber Calibration Data Z. Szillási 1,2, N. Béni 1,2, P. Raics 2, Zs. Szabó 2, J. Molnár 3 G. Bencze 2,4 1 Author for correspondence, editor 2 Institute of Experimental Physics,University

More information

Study of Mixed Gas Flow Pattern Inside RPC

Study of Mixed Gas Flow Pattern Inside RPC Study of Mixed Gas Flow Pattern Inside RPC S. D. Kalmani a,1, P.V. Verma a, R. P. SHINDE b and P. V. Hunagund c a Dept. of High Energy Physics, Tata Institute of Fundamental Research, Mumbai, India. b

More information

a division of Enviro Safety Products

a division of Enviro Safety Products www.minutemanvac.com, a division of Enviro Safety Products.800.637.6606 Chassis 3 4 5 3 4 6 7 8 5 0 0 6 8 0 7 4 3 5 6 7 E 7e www.minutemanvac.com, a division of Enviro Safety Products.800.637.6606 Page

More information

A Longterm Aging Study of the Honeycomb Drift Tubes of HERA-B Using a Circulated and Purified CF -Gas Mixture

A Longterm Aging Study of the Honeycomb Drift Tubes of HERA-B Using a Circulated and Purified CF -Gas Mixture A Longterm Aging Study of the Honeycomb Drift Tubes of HERA-B Using a Circulated and Purified CF -Gas Mixture 4 M. Capeáns, K. Dehmelt, M. Hohlmann, B. Schmidt a c b b c a CERN (Geneva) b DESY (Hamburg)

More information

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 The following tasks parallel the Jr. Tech (JT-1, 2, 3) description and development plan and use the Refrigeration and Air conditioning

More information

MoveRoll Conveyor Operating and Maintenance Manual

MoveRoll Conveyor Operating and Maintenance Manual MoveRoll Conveyor Operating and Maintenance Manual 1. Read this first! This manual contains information for protection of personnel in the roll handling area from possible injury and/or equipment damage.

More information

Developing a Portwide Asset Management Program

Developing a Portwide Asset Management Program Developing a Portwide Asset Management Program American Association of Port Authorities Marine Terminal Management Training Program September 17, 2015 Colin Chung, PhD President, Kayuga Solution Asset

More information

arxiv: v1 [physics.ins-det] 6 May 2016

arxiv: v1 [physics.ins-det] 6 May 2016 Preprint typeset in JINST style - HYPER VERSION Effect of water vapor on the performance of glass RPCs in avalanche mode operation arxiv:15.67v1 [physics.ins-det] 6 May 16 K. Raveendrababu a,d, P. K. Behera

More information

THE WONDERLAND OF OPERATING THE ALICE EXPERIMENT. The Challenges of Operating a Large Physics Experiment

THE WONDERLAND OF OPERATING THE ALICE EXPERIMENT. The Challenges of Operating a Large Physics Experiment THE WONDERLAND OF OPERATING THE ALICE EXPERIMENT The Challenges of Operating a Large Physics Experiment Introduction and context The evolution of the experiment The challenges and how to master them How

More information

Integrated test of the TRD Gas System electronics

Integrated test of the TRD Gas System electronics Integrated test of the TRD Gas System electronics A. Bartoloni, B. Borgia, F. Bucci, F.R. Spada Dipartimento di Fisica, University of Rome La Sapienza and INFN Sezione di Roma Piazzale Aldo Moro, 2 I-00185,

More information

Minutes of the ALICE Technical Board, CERN The draft minutes of the March 2013 TB meeting were approved without any changes.

Minutes of the ALICE Technical Board, CERN The draft minutes of the March 2013 TB meeting were approved without any changes. ALICE MIN-2013-4 TB-2013 Date 25.04.2013 Minutes of the ALICE Technical Board, CERN 25.04.2013 1. Minutes The draft minutes of the March 2013 TB meeting were approved without any changes. 2. Status of

More information

Max Planck Institute, Munich. January 10, Because of the concern about long-term silicon contamination of MDTs, we

Max Planck Institute, Munich. January 10, Because of the concern about long-term silicon contamination of MDTs, we ATLAS Internal Note MUON-N0-104 Eect of Vacuum Grease on Helium Leak Rate Through O-Rings T. Ferbel and A. Manz Max Planck Institute, Munich January 10, 1995 Abstract: Because of the concern about long-term

More information

GLAST Large Area Telescope: I & T Input to Monthly Technical/Cost/Schedule Review 09/27/05

GLAST Large Area Telescope: I & T Input to Monthly Technical/Cost/Schedule Review 09/27/05 Gamma-ray Large Area Space Telescope GLAST Large Area Telescope: I & T Input to Monthly Technical/Cost/Schedule Review 09/27/05 Elliott Bloom SU-SLAC Subsystem Manager Ken Fouts SU-SLAC Subsystem Engineering

More information

RAMSTM. 360 Riser and Anchor-Chain Integrity Monitoring for FPSOs

RAMSTM. 360 Riser and Anchor-Chain Integrity Monitoring for FPSOs RAMS 360 Riser and Anchor-Chain Integrity Monitoring for FPSOs Introduction to RAMS Tritech s RAMS is a 360 anchor-chain and riser integrity monitoring system for Floating Production Storage and Offloading

More information

CCT-7320/ROC-2313 Reverse Osmosis Controller

CCT-7320/ROC-2313 Reverse Osmosis Controller CCT-7320/ROC-2313 Reverse Osmosis Controller 1 General The instrument is a combined control instrument of a reverse osmosis controller and an on-line conductivity instrument. It can perform the operation

More information

User s Guide. Pressure Controller for liquid delivery systems

User s Guide. Pressure Controller for liquid delivery systems Flow Control User s Guide Pressure Controller for liquid delivery systems Precise Pressure Control throughout the experiment Flow control Compatible with any perfusion system Ideal for Small Volume Delivery

More information

AUTOMATIC GAS MANIFOLDS

AUTOMATIC GAS MANIFOLDS AUTOMATIC GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com

More information

Performance of a triple-gem detector for high rate charged particle triggering

Performance of a triple-gem detector for high rate charged particle triggering Performance of a triple-gem detector for high rate charged particle triggering G. Bencivenni a,p.desimone a,f.murtas a, M. Poli Lener a1, W. Bonivento b, A. Cardini b,c.deplano b,d.pinci b,c, D. Raspino

More information

Tri-Tech Medical Inc.

Tri-Tech Medical Inc. Introduction Tri-Tech Medical manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists

More information

Introduction GUIDELINES FOR INSTALLATION PREINSULATED TUBE UNITHERM... Principal of Operation

Introduction GUIDELINES FOR INSTALLATION PREINSULATED TUBE UNITHERM... Principal of Operation GUIDELINES FOR INSTALLATION PREINSULATED TUBE UNITHERM... Introduction Principal of Operation The use of DEKORON/UNITHERM pre-insulated steam supply and condensate return lines offers cost savings features

More information

CBC2 performance with switched capacitor DC-DC converter. systems meeting, 12/2/14

CBC2 performance with switched capacitor DC-DC converter. systems meeting, 12/2/14 CBC2 performance with switched capacitor DC-DC converter systems meeting, 12/2/14 1 reminder of results from CBC1 +2.5V GND 1n can power CBC from single +2.5V supply 1uF DC-DC diff. clock (CMOS) 1 MHz

More information

Installation, use and maintenance instructions. Gas burner (5)

Installation, use and maintenance instructions. Gas burner (5) Installation, use and maintenance instructions Gas burner MODEL GAS 4 TYPE 516 T80 291 (5) TECHNICAL FEATURES Thermal output 180-470 kw 154.800-404.200 kcal/h Fuel Natural gas Pci 8-10 kwh/m 3 = 7000-8600

More information

GLAST Large Area Telescope:

GLAST Large Area Telescope: Gamma-ray Large Area Space Telescope GLAST Large Area Telescope: Electronics, Data Acquisition & Flight Software W.B.S 4.1.7 Face-To-Face June 15 Meeting Gunther Haller haller@slac.stanford.edu (650) 926-4257

More information

Slide and Turn System SF35

Slide and Turn System SF35 Profile system Framed slide and turn system Non-thermally insulated aluminum profiles with insulated glass Option of flush or weathered bottom track The flush bottom track is particularly suitable for

More information

MURAVES muography project

MURAVES muography project MURAVES muography project Giovanni Macedonio (on behalf of the MURAVES Collaboration) Istituto Nazionale di Geofisica e Vulcanologia Osservatorio Vesuviano, Naples, Italy Tokyo, 7 November 2016 G.Macedonio

More information

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG)

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG) Page 1 of 10 CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG) 1. SCOPE 1.1 To provide definitive requirements for HIGH PRESSURE PNEUMATIC testing of piping systems according to ASME B31.3. This

More information

5 Channel Calibrator

5 Channel Calibrator 212 N. Woodwork Lane Palatine, IL 60067 800-223-3977 5 Channel Calibrator Part # 0724 User Manual Questions? Contact us at 800-223-3977 or online at http://www.cleanair.com/equipment/express/main.html

More information

INSTALLATION PROCEDURE FOR OPGW FIBER OPTIC CABLES

INSTALLATION PROCEDURE FOR OPGW FIBER OPTIC CABLES Page 1 of 15 INSTALLATION PROCEDURE FOR OPGW FIBER OPTIC CABLES Page 2 of 15 1. PURPOSE 2. SCOPE 3. REFERENCES 4. GENERAL INDEX 5. PROCEDURES 5.1 Line survey 5.2 Transport, loading, unloading and storage

More information

INTRODUCTION TO THE SERVICE RIFLE AND MAINTENANCE

INTRODUCTION TO THE SERVICE RIFLE AND MAINTENANCE INTRODUCTION TO THE SERVICE RIFLE AND MAINTENANCE 1 OVERVIEW DISASSEMBLY MAINTENANCE ASSEMBLY 2 TERMINAL LEARNING OBJECTIVE Given a service rifle, Common Combat Sling, and cleaning gear maintain a service

More information

PH01 Perfusion Cannula Manual

PH01 Perfusion Cannula Manual PH01 Perfusion Cannula Manual Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted without the express written permission of Multi

More information

Quadair. Air Hockey Table Owners Manual. Assembly operation and care instuctions. Serial # Distributed By. Sales Person. Technical Service #

Quadair. Air Hockey Table Owners Manual. Assembly operation and care instuctions. Serial # Distributed By. Sales Person. Technical Service # Version 12.1.11 Quadair Air Hockey Table Owners Manual Assembly operation and care instuctions. Serial # Distributed By Sales Person Technical Service # QUADAIR PATENTED WORLDWIDE Forward First, we would

More information

Assembling and testing fluid power systems

Assembling and testing fluid power systems Unit 020 Assembling and testing fluid power systems Level: 2 Credit value: 14 NDAQ number: 500/9514/6 Unit aim This unit covers the skills and knowledge needed to prove the competences required to cover

More information

THE ADVANCED DIGITAL SNOW SONDE

THE ADVANCED DIGITAL SNOW SONDE THE ADVANCED DGTAL SNOW SONDE Osamu ABE*, Hiroo SATO**, Mitsuharu CHBA** and Shizuo TANASAWA** * Shinjo Branch of Snow and ce Studies, NED, Shinjo, 996-0091 Japan ** ADTEX Co. Ltd., Takasaki, 370-1201

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Engineering Design Challenge 3. Mars Colonization. Rules & Game Description

Engineering Design Challenge 3. Mars Colonization. Rules & Game Description 3 Mars Colonization Rules & Game Description Congratulations! Your job application to Lebanese Rocket Society Mars Division has been accepted! As head of the Robotics team, you are in charge of building

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

Technical Service Bulletin March 2015 TSB142.01

Technical Service Bulletin March 2015 TSB142.01 Technical Service Bulletin March 2015 TSB142.01 Commissioning Procedure for HYDRAcap This Technical Service Bulletin provides information for commissioning of a HYDRAcap membrane system in a water treatment

More information

GLAST Large Area Telescope:

GLAST Large Area Telescope: Gamma-ray Large Area Space Telescope GLAST Large Area Telescope: Electronics, Data Acquisition & Flight Software W.B.S 4.1.7 June Monthly Review Gunther Haller haller@slac.stanford.edu (650) 926-4257 4.1.7

More information

RM-80 respiration monitor

RM-80 respiration monitor RM-80 respiration monitor User Manual September 18, 2015 0025-003M 950 North Hague Avenue Columbus, Ohio 43204-2121 USA Sales: sales@colinst.com Service: service@colinst.com Phone: (614) 276-0861 Fax:

More information

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION Exercise 2-2 Second-Order Interacting Processes EXERCISE OBJECTIVE Familiarize yourself with second-order interacting processes and experiment with the finer points of controller tuning to gain a deeper

More information

Part 1 General Information Part 2 Outdoor Units... 8

Part 1 General Information Part 2 Outdoor Units... 8 Contents Part 1 General Information... 1 Part 2 Outdoor Units... 8 Part 3 Installation... 71 Part 4 Part 5 Trouble shooting 99 Control system. 126 Manufacture reserves the right to discontinue, or change

More information

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series

Installation Operating Instructions for Duplex Manual Manifolds PX-TMD Series Introduction Powerex manifolds are cleaned, tested and prepared for the indicated gas service and are built in accordance with the Compressed Gas Association guidelines. The manifold consists of a regulator

More information

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations

INSTALLATION, CARE & USE MANUAL. EMASMB & LMASMB Surface Mount Bottle Filling Stations INSTALLATION, CARE & USE MANUAL EMASMB & LMASMB Surface Mount Bottle Filling Stations IMPORTANT THIS IS AN INDOOR APPLICATION ONLY! ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSONNEL. TOOLS/ITEMS

More information

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 0700 67 Registered in England and Wales No. 05058855

More information

2 Switching off ECRIS 3. 4 Acquire Beam Spectrum 4. 6 Vent Instrument Chamber 5. 7 Pump down Chamber 5. 8 Baking out Chamber 5.

2 Switching off ECRIS 3. 4 Acquire Beam Spectrum 4. 6 Vent Instrument Chamber 5. 7 Pump down Chamber 5. 8 Baking out Chamber 5. Contents 1 Starting the ECR ion source (ECRIS) 2 2 Switching off ECRIS 3 3 Starting Mefisto Beam Analyzer 4 4 Acquire Beam Spectrum 4 5 Open Valve ECRIS/Chamber (Gate valve) 4 6 Vent Instrument Chamber

More information

TIPPMANN 98 CUSTOM. Owner s Manual CO2 POWERED PAINTBALL GUN

TIPPMANN 98 CUSTOM. Owner s Manual CO2 POWERED PAINTBALL GUN TIPPMANN PNEUMATICS, INC. Get Your ur Heart t Pound unding With h A Tippmann! WARNING: This paintball marker/gun is not a toy nor is it intended for unsupervised use by persons under the age of 18 years.

More information