1 EB/EE Status & Plans Status: Recent Highlights Status: Interesting re-discovery Status: To-Do List Principal items EB/EE Plans for remainder of CRAFT Preliminary Shutdown Schedule 1
2 Recent Highlights 1) EE very rapidly & successfully integrated into CMS global data-taking 2) All EB/EE services basically running reliably: LV, HV, cooling, DCS 3) DAQ running stably in CRAFT: EB: Gain=200 good for seeing Cosmics Gain=50 better for LASER and is final configuration ~255M cosmics at B=3.8T, ~30M at B=0, ~60/40 with Gain=50/200 EE: less data, due to DCC/LED/TCC improvements (magnet trips: HV 0) 4) LASER sequence now routine : many hundreds of cycles recorded 5) Channel LASER timings now good to +/- 2ns 6) 9 EB TTs recently recovered (Dead Good) 7) EB Trigger: Rate stable & as expected, timed-in with other subdetectors 8) Central CMS DCS can now control EB-DCS; EB LV/HV archiving in Cond-DB 9) EB/EE cooling regulation improved: e.g. all EB/EE switched On/Off together 10) EE VPTs much more (x20) stable at B=3.8T than at B=0T 2
3 Interesting re-discovery of effect of magnetic field EB Pedestal Value increases systematically with increasing magnetic field EB Pedestal RMS is independent of B ~10% of the shift depends on B direction with respect to VFE Card orientation! Effect much reduced in EE (<1 ADC count) Confirmation of MTCC shift, but still not actually understood Calibrate away when re-do Pedestal Offset Scan at B=3.8T 3
4 To-Do List: LV Overheating at power distribution cabinets recabling/cooling necessary Recabling of power into OPFCs for improved safety margin OPFC upgrade for better monitoring Finish upgrade of Maratons (MEM-type partially remaining) EB+7: 2 short-circuits (hopefully outside SM!) EB+16: 1 channel doesn t like B=3.8T! EB-11 TT60 VFE1-3: 15-channels lost EE-5 TT32 (D3): LVR problem 25-channels lost (repair?) Finish EE-LV integration into central DCS and commission archiving 4
5 To-Do List: HV, LASER & LED Systems HV: EB pattern noise : much better after closing CMS, but EE HV distribution boxes: go to final version EE HV problem channels: 1 Super-Crystal (D1) doesn t get Anode HV (lost inside Dee) 1 Super-Crystal (D1) has short on Anode (to be investigated) 2-3 S-Cs draw very little current when LEDs pulsed (to be investigated) Integrate EE-HV into central DCS and commission archiving LASER System: Finish upgrade to cooling of LASERs; add monitoring Upgrades inside barrack to cope with B=3.8T! Control PC needs remote reboot capability Automation ti of LASER analysis/musecal/fastlasercheck/fill-db l/f EE LED System: Add missing hardware (control boxes etc.) Integration into ECAL Calibration Sequence 5
6 To-Do List: DAQ & Trigger CCS: QPLL locking issues in a few TTs Development of configuration to cope with dead FE cards Add masking of single hot channels from Trigger sums Try to develop concurrent DAQ & DCU data-taking t DCC: Finalisation of firmware for EB/EE TCC/SRP: VME crate upgrade (power distribution) Finalisation of firmware for EB-TCCs Installation & commissioning of EE TCC68 system Finalisation of TCC/SRP/DCC communications DAQ: Improve monitoring of DAQ/Trigger components Orbit Gap Issues, eg: Test-pulse undershoot tail, event-type flagging g LED data-taking, LED pulsing for VPT stability 6
7 To-Do List: And also DCS/ESS: Integrate Temperature/Humidity monitoring into central DCS Integrate DCU data into DCS Finalise application for Maraton-cooling temperature EE D3: noise on Precision temperature Monitoring (Tracker?) Finalise ESS system, e.g. Twido-interlocks i DSS: Commission CMS sniffer system for ECAL ECAL ELOGs: ECAL already at #4400 So important ones get overlooked Should limit the content to information of long-term interest Rest /HyperNews/Chat svp! 7
8 CRAFT: Aims & Modus Operandi 1) Aims: Get EB/EE LASER system running reliably in beam orbit gaps Commission EE LED system; study behaviour of VPTs at B=3.8T Commission EE Trigger (doesn t need Global Run or B=3.8T) DCS: progress towards final system 2) EB/EE Modus Operandi in the last 2 weeks of CRAFT: EB and one Endcap 100% in Global Run for LASER studies at B=3.8T One Endcap 100% in Local mode for R&D: LEDs(3.8T) & TCC68 8
9 Preliminary Shutdown Schedule (1) 9
10 Preliminary Shutdown Schedule (2) 10
11 Key Shutdown Dates for EB/EE Global CMS Shutdown Planning Concept Maintenance of Cooling/Power in parallel with opening of CMS Start as early as possible, in case access to UXC curtailed to improve personnel safety during LHC Cooling/Powering, following 19-Sep Even without this, shutdown barely long enough (no contingency) 0) End of CRAFT/Start of local running: 11-Nov (short el. Cuts 19-Nov & 22-Nov) 1) No IP5 Cooling: 24-Nov 10-Dec 2) Limited IP5 Cooling: 10-Dec 19-Dec 3) No IP5 Cooling: 20-Dec 05-Jan 4) Limited IP5 Cooling: 09-Jan 19-Jan 1) No EB/EE LV power: 24-Nov 10-Dec 2) LV OK: 10-Dec 19-Dec 3) No EB/EE LV power: 20-Dec 05-Jan 4) Limited CMS power: 05-Jan 19-Jan NB: This is a PLAN; it will change; we must remain flexible, as in the past 11
Top Level of CSC DCS UI
Top Level of CSC DCS UI - CSC normally in central DCS control -cdcs - Central DCS shifter monitors the CSC system, but doesn't take any action without consulting with the CSC shifter - CSC Shifter also
More informationTHE WONDERLAND OF OPERATING THE ALICE EXPERIMENT. The Challenges of Operating a Large Physics Experiment
THE WONDERLAND OF OPERATING THE ALICE EXPERIMENT The Challenges of Operating a Large Physics Experiment Introduction and context The evolution of the experiment The challenges and how to master them How
More informationMDT Status: Installation and Commissioning
MDT Status: Installation and Commissioning 5 3 4 6 7 2 8 Missing 9 stations 1 9 1 6 1 0 1 5 1 4 1 2 1 1 L. Pontecorvo Outline Installation and infrastructure status Commissioning Status Sector Commissioning
More informationSiPM readout experience and prospects
SiPM readout experience and prospects Felix Sefkow DESY CALICE collaboration ALCPG workshop at Snowmass August 23, 2005 This talk SiPM mass production and tests Experience with multi-channel readout Future
More informationCBC2 performance with switched capacitor DC-DC converter. systems meeting, 12/2/14
CBC2 performance with switched capacitor DC-DC converter systems meeting, 12/2/14 1 reminder of results from CBC1 +2.5V GND 1n can power CBC from single +2.5V supply 1uF DC-DC diff. clock (CMOS) 1 MHz
More informationAnalysis of RPC Performance with Different Gas Mixture
Analysis of RPC Performance with Different Gas Mixture Cern Summer Student Programme Report Xing FAN xfan@icepp.s.u-tokyo.ac.jp 11/Sep/2015 Supervisor: Beatrice Mandelli (CERN PH-DT) 1 Introduction 1.1
More informationOptonPro. High-power laser up to 7000 mw. Laser therapy natural healing with the power of light
GB High-power laser up to 7000 mw Laser therapy natural healing with the power of light Application of high-power light for targeted penetration of high amounts of energy deep into the tissue. Initiates
More informationSorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply
Sensen DCS Series General Purpose Systems Power Supply High power density / low ripple and noise High programming resolution with Ethernet interface Constant voltage and current mode Remote sensing Isolated
More informationThe Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad
The Resistive Plate Chamber detectors at the Large Hadron Collider experiments Roberto Guida PH-DT-DI Danube School, September 8-13, 2014 Novi Sad Ionization chambers Ionizing particles are producing primary
More informationWELCOME TO THE REVOLUTION
USER GUIDE WELCOME TO THE REVOLUTION THANK YOU FOR CHOOSING THE GCQUAD We listened to what you wanted - and created the most accurate, versatile and game-enhancing ball and club analysis solution available
More informationHOT SPOT MONITOR (HSM)
HOT SPOT MONITOR (HSM) EDS FILE TECHNICAL NOTE INSERTING EDS TO ROCKWELL STUDIO 5000 Follow the below steps to add GraceSense TM Hot Spot Monitor (HSM) product via Ethernet IP to your project. Download
More informationThese Terms and conditions apply to audit trails incorporated in weighing and measuring devices and systems 1.
Title: Terms and Conditions for the Approval of Metrological Audit Trails Effective Date: 2006-03-16 Page: 1 of 9 Revision: 1.0 Application These Terms and conditions apply to audit trails incorporated
More informationNeles trunnion mounted ball valve Series D Rev. 2. Safety Manual
Neles trunnion mounted ball valve Series D Rev. 2 Safety Manual 10SM D en 1/2017 2 Neles trunnion mounted ball valve, Series D Table of Contents 1 Introduction...3 2 Structure of the D series trunnion
More informationAssembly and Testing of RPCs in Pakistan. Hafeez Hoorani National Centre for Physics
Assembly and Testing of RPCs in Pakistan Hafeez Hoorani National Centre for Physics 1 Layout Introduction RPCs in CMS RPC: From Lab to Detector Assembly Testing QA & QC Installation and Commissioning 2
More informationTEC Petal Integration & Lt Pilot Centres
TEC Petal Integration & Lt Pilot Centres Wim Beaumont 4, Guido Dirkes 1, Stefan Heier 1, Thomas Keutgen 3, Otilia Militaru 3, Benjamin Trocme 2, Valery Zhukov 1 1 Karlsruhe --- Institut fur Experimentelle
More informationPositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible
Change from one to two columns Technical Information TI/EDP300_ED-EN Rev. A PositionMaster EDP300 Extended Diagnostics Compact, well-proven, and flexible The benefits of the extended diagnostics feature
More informationPRC CO ² -LASER PRESENTATION
Page 1 of 7 PRC CO ² -LASER PRESENTATION GENERAL CHARACTERISTICS - Embedded PC104 Electronics with exchangeable software allowing very easy integration of customer specified functions: such as eg. specific
More informationSeries 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST)
Series 3730 and Series 3731 EXPERTplus Valve Diagnostics with Partial Stroke Test (PST) Application Positioner firmware for early detection of control valve faults giving maintenance recommendations. Valid
More informationUK Opportunities in SiD Calorimetry
UK Opportunities in SiD Calorimetry Paul Dauncey Imperial College London 7 Sept 2007 Paul Dauncey - Calorimetry 1 Overview SiD is designed for particle flow Calorimeters will be optimised using particle
More informationScan of Recent high MET events
Scan of Recent high MET events Jordan Damgov, Chiyoung Jeong Sung-Won Lee Texas Tech University MET working group meeting 12 Nov, 2010 Data sets, Events selection Dataset (PD): /METFwd/Run2010B-PromptReco-v2/RECO
More informationSurface Tracking Feature
TELEDYNE RD INSTRUM ENTS A Teledyne Technologies Company Application Note FSA-022 (June 2008) Surface Tracking Feature 1 Introduction The following Application Note serves as a guide of how to use the
More informationBurner Management System DEMO Operating instructions
Burner Management System DEMO Operating instructions Burner Management System DEMO Operating Instructions Startup Summary - Normal startup is accomplished in four basic steps: 1. Leak Test a. Safety Valve
More informationLEADER SEARCH RADAR LIFE LOCATOR
INTRODUCTION OF: Ultra Wide Band Victims detector & Locator V30.09.13.00 Product Concept i. The is designed to be simplistic in use whilst producing reliable and accurate information in the search for
More informationHyperSecureLink V6.0x User Guide
HyperSecureLink V6.0x User Guide Note: This software works with the LS-30 Version (06.0x or later) 1, Hardware Installation: 1-1, Connection Diagram for USB or RS-232 Computer Interface To LS-30 CM1 To
More informationKARL SUSS MJB3 UV400 Mask Aligner Standard Operating Procedure
KARL SUSS MJB3 UV400 Mask Aligner Standard Operating Procedure Version: 1.0 February 2014 UNIVERSITY OF TEXAS AT ARLINGTON Nanotechnology Research Center (NRC) 1 TABLE OF CONTENTS 1 Introduction 3 1.1
More informationATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502
ATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
More informationReferences, characteristics. References (1) Complementary characteristics not shown under general characteristics (page 30395/3)
References, characteristics Electromechanical pressure switches For power circuits, type XMP. IP degree of protection Size (87 psi). Adjustable differential, for regulation between thresholds Switches
More informationBuilt-in Purge Control Functions
Built-in Purge Control Functions Why clean a sensor? As the velocity sensor was calibrated clean, operating it clean also preserves the best calibration. Any build up of material on a thermal sensor tends
More informationarxiv: v1 [physics.ins-det] 16 Aug 2014
Preprint typeset in JINST style - HYPER VERSION RPC Gap Production and Performance for CMS RE4 Upgrade arxiv:1408.3720v1 [physics.ins-det] 16 Aug 2014 Sung Keun Park, Min Ho Kang and Kyong Sei Lee Korea
More informationEasyTouch. Pool and Spa Control Systems By Pentair Water Pool and Spa. Because automation makes it all so simple
EasyTouch Pool and Spa Control Systems By Pentair Water Pool and Spa Because automation makes it all so simple EasyTouch Pool and Spa Control Systems Who says pool automation has to be costly and complicated?
More informationPartial Stroke Testing for SRD991 and SRD960
Technical Information 09.11 TI EVE0105 PST-(en) Partial Stroke Testing for SRD991 and SRD960 Final control elements in Emergency Shutdown (ESD) applications such as ON-OFF-, Blow Down and Venting-Valves
More informationEASYTOUCH. Because automation makes it all so simple. pentairpool.com
EASYTOUCH EASYTOUCH CONTROL SYSTEMS PAIRED WITH AUTOMATED CHEMICAL MANAGEMENT Because automation makes it all so simple pentairpool.com EASYTOUCH CONTROL SYSTEMS Who says pool automation has to be costly
More informationTRANSFER SYSTEM DESCRIPTION...3
Pa mphl e t57 Eme r g e n c ys h u t-of f S y s t e msf o rbu l ktr a n s f e r o fch l o r i n e Ed i t i o n5-re v i s i o n1 Ma r c h2009 Table of Contents 1. INTRODUCTION...1 1.1 SCOPE...1 1.2 CHLORINE
More informationJamesbury Pneumatic Rack and Pinion Actuator
Jamesbury Pneumatic Rack and Pinion Actuator Valv-Powr Series VPVL Rev. 3.0 Safety Manual 10SM VPVL en 5/2017 2 Jamesbury Pneumatic Rack and Pinion Actuator, Valv-Powr Series VPVL, Rev 3.0, Safety Manual
More informationThe Race Director. IPICO Integration Direct Connect [IPICO INTEGRATION]
2017 The Race Director IPICO Integration Direct Connect [IPICO INTEGRATION] This document explains how to manage the results data between your IPCIO readers and Race Director using a direct connection
More informationUSER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a
ATMOSPHERE APS TM Series Haze Generator MAX APS TM Series Fog Generator USER GUIDE No: 120815, Revision A/a MADE IN CANADA FABRIQUÉ AU CANADA Les Générateurs de Brouillard Ltée / Fog Generators Ltd 10301
More informationThe benefits of the extended diagnostics feature. Compact, well-proven, and flexible
ABB MEASUREMENT & ANALYTICS TECHNICAL INFORMATION PositionMaster EDP300 Extended Diagnostics Compact, well-proven, and flexible The benefits of the extended diagnostics feature The PositionMaster EDP300
More informationRICK FAUSEL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES
RICK FAUL, BUSINESS DEVELOPMENT ENGINEER TURBOMACHINERY CONTROL SYSTEM DESIGN OBJECTIVES The primary design objective for any turbomachinery control system should be to maintain or maximize machine and
More informationarxiv: v1 [hep-ex] 18 Sep 2012
Preprint typeset in JINST style - HYPER VERSION arxiv:109.3893v1 [hep-ex] 18 Sep 01 Performance of the Gas Gain Monitoring system of the CMS RPC muon detector and effective working point fine tuning S.
More informationEasyTouch. Because automation makes it all so simple. Pool and Spa Control Systems. by Pentair Water Pool and Spa
EasyTouch Pool and Spa Control Systems by Pentair Water Pool and Spa Because automation makes it all so simple EasyTouch Pool and Spa Control Systems Who says pool automation has to be costly and complicated?
More informationUSER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d
ATMOSPHERE APS Series Haze Generator MAX APS Series Fog Generator USER GUIDE No: 120815, Revision A/d MADE IN CANADA FABRIQUÉ AU CANADA Les Générateurs de Brouillard Ltée / Fog Generators Ltd 10301 avenue
More informationImproving the Measurement Accuracy of Water Partial Pressure Using the Major Constituent Analyzer
Improving the Measurement Accuracy of Water Partial Pressure Using the Major Constituent Analyzer Ben D. Gardner, Phillip M. Erwin, Wai Tak Lee, Amber M. Tissandier, Souzan M. Thoresen Hamilton Sundstrand
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More informationSpecifications and information are subject to change without notice. Up-to-date address information is available on our website.
www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is available on our website. web: www.smar.com/contactus.asp LD302 - AssetView HMI LD302
More informationBSP Pressure Sensor Balluff GmbH, BA Marco Zorcic.
1 2 Standard Pressure Sensor with display Overview Pressure Range Relative nominal Overload Burst Permitted negative -1..2 bar 2 bar 4 bar 10 bar -1..10 bar 10 bar 20 bar 35 bar 0..2 bar 2 bar 4 bar 10
More informationCryostream 800 Series
Cryostream 800 Series Cryostream 800 Series Nearly 30 years after the invention of the first Cryostream Cooler, Oxford Cryosystems is proud to announce the launch of the new 800 series Cryostream. The
More informationData Sheet T 8389 EN. Series 3730 and 3731 Types , , , and. EXPERTplus Valve Diagnostic
Data Sheet T 8389 EN Series 3730 and 3731 Types 3730-2, 3730-3, 3730-4, 3730-5 and Type 3731-3 Electropneumatic Positioners EXPERTplus Valve Diagnostic Application Positioner firmware to detect potential
More informationInspection of CANDU Reactor Pressure Tubes Using Ultrasonics
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Inspection of CANDU Reactor Pressure Tubes Using Ultrasonics Michael TRELINSKI Inspection & Maintenance Services Ontario
More informationStatus of MDT Production and Testing
Sandra Horvat Max-Planck-Institut für Physik Status of MDT Production and Testing September 13-19, 2003 // ATLAS Overview Week // Praha, Czech Republic Outline Introduction: MDT Chambers (Monitored Drift
More informationDimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)
Proportional damper actuator, non-spring return, Multi-Function Technology Torque min. Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) For proportional modulation of dampers in HVC systems. The is
More informationDrift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer
Drift-Chamber Gas System Controls Development for the CEBAF Large Acceptance Spectrometer M. F. Vineyard, T. J. Carroll, and M. N. Lack Department of Physics University of Richmond, VA 23173 ABSTRACT The
More informationPHOENIX L300i Best-in-class Helium Leak Detectors
180.85.02 Best-in-class Helium Leak Detectors The perfect Helium leak detector matching your demands The helium leak detector opens up new dimensions of productivity and reliability for your applications.
More informationThe HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator
The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Universal pycnometer, no
More informationPoint level switches for safety systems
Point level switches for safety systems By: Bill Sholette Level Products Business Manager Northeast US - Endress+Hauser Point level switches are often used in applications designed to prevent accidents.
More informationAirborne Coherent Wind Lidar measurements of vertical and horizontal wind speeds for the investigation of gravity waves
Airborne Coherent Wind Lidar measurements of vertical and horizontal wind speeds for the investigation of gravity waves 18 th Coherent Laser Radar Conference, Boulder, CO, USA 27 June to 1 July 2016 Benjamin
More information7250 Sys. Ruska Multi-Range Pressure Calibration System. GE Sensing & Inspection Technologies. Features. Applications
GE Sensing & Inspection Technologies 7250 Sys Ruska Multi-Range Pressure Calibration System Features Fully integrated multi-range pressure test and calibration systems Select either an eight range or the
More informationPLANNED LIGHTING MAINTENANCE LTD METHOD STATEMENT & RISK ASSESSMENT REPLACEMENT OF LAMPS OR REPAIRS TO HIGH LEVEL LIGHT UNITS
PLANNED LIGHTING MAINTENANCE LTD METHOD STATEMENT & RISK ASSESSMENT REPLACEMENT OF LAMPS OR REPAIRS TO HIGH LEVEL LIGHT UNITS Project: (insert Client) Replacement/ Repair of high level light units/ high
More informationWATER CONTROL SYSTEM QUICK START
SETTINGS MENU SYSTEM OPTIONS WATER LEVEL BAR GRAPH 3 DS SPRAY ON/OFF CS SPRAY ON/OFF BEACON WATER CONTROL SYSTEM QUICK START WWW.GFWORLDWIDE.COM +1 (208) 664-9291 SERVICE@GFWORLDWIDE.COM DISPLAY SCREEN
More informationSHELL FLAGS INSPECTION CASE STUDY
SHELL FLAGS INSPECTION CASE STUDY J. Nonemaker, Solution Engineer, ROSEN T. Steinvoorte, Business Development, ROSEN R. Subramanian, Pipelines & Subsea Technical Support Engineer, Shell U.K. Limited Introduction
More informationINNOVATIVE MOORING SYSTEMS
INNOVATIVE MOORING SYSTEMS VESSEL AUTOMOORING MODULES QUAY AUTOMOORING INSTALLATIONS DOCKLOCK brings mooring to a next level PAGE 2 FOR OVER A CENTURY THE WORLD S LEADING EXPERT IN MOORING, BERTHING AND
More informationGas System Status Report
Gas System Status Report UGPS qualification Rome Control Electronics production schedule Gas circuit testing Software commands and safety Report from MIT B. Borgia TIM April 2006 Gas Circuit B. Borgia
More informationFlexibility Enhancements for Gas Turbines
Flexibility Enhancements for Gas Turbines 7/11/2016 Situation Renewable Energy installed capacity is still increasing currently >13% of US total installed capacity. Wind and Solar with their characteristic
More informationIn Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure
PPMS Service Note 1099-412 In Response to a Planned Power Outage: PPMS EverCool II Shut Down and Re-start Procedure Introduction: Loss of electricity to the PPMS EverCool II should not cause damage to
More informationManaging for Liability Avoidance. (c) Lewis Bass
Managing for Liability Avoidance (c) Lewis Bass 2005 1 Staying Safe in an Automated World Keys to Automation Safety and Liability Avoidance Presented by: Lewis Bass, P.E. Mechanical, Industrial and Safety
More informationRPS900W Redundant Power Supply. Installation Guide.
RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A
More informationElectronic Volume Correctors
Electronic Volume Correctors Ben Manson Landis+Gyr October 14, 2016 PUBLIC Agenda Customer Types and suitable equipment Volume corrector standards / regulations Basics of volume correction Gauge v Absolute
More informationNational Robotics Competition 2018 NRC WRO Challenge Manual
National Robotics Competition 2018 NRC WRO Challenge Manual Page 1 of 13 A. Competition Categories World Robot Olympiad has three regular competition categories, and an Open category: 1. Regular Category
More informationFigure 1 The LHC cryogenic islands and plants layout
The LHC cryogenic operation for first collisions and physics run Brodzinski K, Barth K, Benda V, Bremer J, Casas-Cubillos J, Claudet S, Delikaris D, Ferlin G, Fernandez Penacoba G, Perin A, Pirotte O,
More informationOLED vacuum deposition cluster system Sunicel Plus 400 / Plus 400L (Sunic Systems)
OLED vacuum deposition cluster system Sunicel Plus 400 / Plus 400L (Sunic Systems) Gen2 substrate size : 370 (+/- 0.2) mm x 470 (+/- 0.2) mm. Thickness : 0.55 to 2.0mm. Supports the following deposition
More informationFuel Gas Pressure Control Solutions for Fired Heaters and Boilers
Fuel Gas Control Solutions for Fired Heaters and Boilers Solutions for safer and more reliable operation of fired heater fuel gas systems. Prevent process downtime by keeping your critical heaters online.
More informationNew Thinking in Control Reliability
Doug Nix, A.Sc.T. Compliance InSight Consulting Inc. New Thinking in Control Reliability Or Your Next Big Headache www.machinerysafety101.com (519) 729-5704 Control Reliability Burning Questions from the
More informationProvider ICD 10 Compliant Release A S K E S I S W E B I N A R F E B R U A R Y 1 9,
Provider 7.2.6 ICD 10 Compliant Release A S K E S I S W E B I N A R F E B R U A R Y 1 9, 2 0 1 4 Agenda ICD 10 overview Application development path to compliance Objectives Components CMS 1500 Documentation
More informationOperating Instructions EB EN. Series 373x Electropneumatic Positioner Type 373x-5 EXPERT + with FOUNDATION fieldbus communication
Series 373x Electropneumatic Positioner Type 373x-5 EXPERT + with FOUNDATION fieldbus communication Fig. 1 Valve diagnostics with TROVIS-VIEW Operator Interface Operating Instructions EB 8388-5 EN Firmware
More informationINSPECTION OF RECOVERY BOILERS
INSPECTION OF RECOVERY BOILERS W. B. A. (Sandy) Sharp SharpConsultant, Columbia, Maryland, U.S.A. TAPPI Kraft Recovery Short Course St. Petersburg, Florida, January 7-10, 2008 OUTLINE Purpose of inspections
More informationSafety and Risk Engineering. HSE Case Implementation Clive Rawson
Safety and Risk Engineering HSE Case Implementation Clive Rawson Purpose ALARP Risk Assessment Major Accident Events Bowties Safety Critical Systems Performance Standards Implementation Getting HSE Case
More informationTEK-THERMAL 1700B. Thermal Mass Flowmeter. FLOW. Technology Solutions
Technology Solutions TEK-THERMAL 1700B Thermal Mass Flowmeter FLOW www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Thermal 1700B Thermal Mass Flowmeters,
More informationICES advice on fishing opportunities
ICES Advice on fishing opportunities, catch, and effort Greater North Sea Ecoregion Published 29 June 2018 Version 2: 3 July 2018 Version 3: 14 November 2018 https://doi.org/10.17895/ices.pub.4458 Sole
More informationHigh performance disc valves Series Type BA, BK, BW, BM, BN, BO, BE, BH Rev Safety Manual
High performance disc valves Series Type BA, BK, BW, BM, BN, BO, BE, BH Rev. 2.0 Safety Manual 10SM B Disc en 4/2018 2 High performance disc valves Series, Type BA, BK, BW, BM, BN, BO, BE, BH, Rev. 2.0
More informationGLAST Large Area Telescope Monthly Mission Review
GLAST Large Area Telescope Monthly Mission Review Gamma-ray Large Area Space Telescope LAT DAQ and Flight Software Status July 28, 2006 Gunther Haller Stanford Linear Accelerator Center Topics Hardware
More informationistart Owner s Manual
istart Owner s Manual istart Whistle istart Pro istart Controller Introduction The istart Whistle, istart Pro and istart Controller are self-contained automatic sailboat race starters using the latest
More informationUniversity of Aberdeen
University of Aberdeen Ionising Radiation Safety Arrangements APPENDIX 9 X-ray Equipment form Version 1 May 2017 Authorised by Radiation Hazards Sub Committee Appendix 9 Version1 X-Ray form Page 1 of 5
More informationThe HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator
The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Temperature controlled, multi-technique volumetric
More informationUser Manual. Heads-Up Display (HUD) DiveCAN. Mechanical Button Version
User Manual Heads-Up Display (HUD) Mechanical Button Version DiveCAN Table of Contents 1. Introduction...4 1.1 Features...4 2. Physical Description...5 3. Reading the PPO2...6 3.1 Modified Smither s Code...7
More informationOxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument
OxyScan Graphic Operating Instructions UMS Micro-oxygen sensor 501 Microprocessor instrument Introduction Thank you for choosing the UMS Micro Oxygen Sensor 501 - a highly advanced product! Please read
More informationUniversity of Minnesota Center for Magnetic Resonance Research Standard Operating Procedure Human System Magnet Operator Training
University of Minnesota Center for Magnetic Resonance Research Standard Operating Procedure Human System Magnet Operator Training SOP Number / Version: SOP001 / Version 2 Approval Date: Implementation
More informationEasyTouch. Because automation makes it all so simple. Pool and Spa Control Systems. By Pentair Water Pool and Spa
EasyTouch Pool and Spa Control Systems By Pentair Water Pool and Spa Because automation makes it all so simple EasyTouch Pool and Spa Control Systems Who says pool automation has to be costly and complicated?
More informationIMCA DP Station Keeping Bulletin 04/18 November 2018
DP STATION KEEPING BULLETIN IMCA DP Station Keeping Bulletin 04/18 November 2018 The following event trees have been compiled from recent reports received by IMCA. The originators granted IMCA permission
More informationPRELIMINARY Presented at the SLSD 7S SORR 9/9/03
PRELIMINARY Presented at the SLSD 7S SORR 9/9/03 Space and Life Sciences Directorate ISS Flight 7 Soyuz Stage Operations Readiness Review Certification of Flight Readiness September 24, 2003 J. B. Walters
More informationThe Best Use of Lockout/Tagout and Control Reliable Circuits
Session No. 565 The Best Use of Lockout/Tagout and Control Reliable Circuits Introduction L. Tyson Ross, P.E., C.S.P. Principal LJB Inc. Dayton, Ohio Anyone involved in the design, installation, operation,
More informationT i m i n g S y s t e m s. RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA (408)
RACEAMERICA T i m i n g S y s t e m s Demo Tree Controller Owner s Manual Models 3204D, 3204DW & 3204DX Rev D RACEAMERICA, Inc. P.O. Box 3469 Santa Clara, CA 95055-3469 (408) 988-6188 http://www.raceamerica.com
More informationHydro-Control V User Guide
Hydro-Control V User Guide Hydronix Part no: HD0193 Version 2.3.0 Revision date: July 2006 1 COPYRIGHT Neither the whole or any part of the information contained in nor the product described in this documentation
More informationRequirements For The Construction Of The LCLS Magnetic Measurements Laboratory
LCLS-TN-04-1 Requirements For The Construction Of The LCLS Magnetic Measurements Laboratory Zachary Wolf, Robert Ruland SLAC February 9, 2004 Abstract A magnetic measurements laboratory will be built at
More informationHumiSys HF High Flow RH Generator
HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously
More informationOverview. Front Panel: Keypad and Display
Overview The GA-200B is an analyzer that integrates a gas sampling system with sensors to measure and display the concentrations of oxygen and carbon dioxide in a sample as the percentage of a gas in the
More informationIMPACT LOCATION SETUP. Updated July 2018
IMPACT LOCATION SETUP Updated July 2018 HOW TM4 DETERMINES IMPACT LOCATION TO DETERMINE IMPACT LOCATION FOUR PARAMETERS ARE NEEDED The ball position before impact, the precise time of impact, the position
More informationPressure calibration. 20
Pressure calibration Pressure calibration is the comparison of the output of a device used to measure pressure with that of another pressure measurement device, or pressure measurement standard. This usually
More informationDistributed Control Systems
Unit 41: Unit code Distributed Control Systems M/615/1509 Unit level 5 Credit value 15 Introduction With increased complexity and greater emphasis on cost control and environmental issues, the efficient
More informationLGP Pneumatic 2-Finger Parallel Gripper Universal Gripper Sizes Weight Gripping force Stroke per finger Workpiece weight
LGP Sizes 8.. 4 Weight.34 kg.. 1.5 kg 27 N.. 19 N Stroke per finger 2 mm.. 13 mm Workpiece weight.65 kg.. 2.5 kg Application example pneumatic double transfer unit 2-Finger Parallel Gripper LGP 2 Universal
More informationSF 6 Product Guide. Gas Analysis Instruments and Accessories
SF 6 Product Guide Gas Analysis Instruments and Accessories Cambridge Sensotec Ltd specialises in the design and manufacture of gas analysis equipment under the Rapidox brand name. Based in the UK, the
More informationCITREX H4 Mobile gas flow analyser. The ideal mobile device for flow and pressure analysing.»
CITREX H4 Mobile gas flow analyser «The ideal mobile device for flow and pressure analysing.» Ventilator tester for mobile use CITREX is designed for mobile and easy use while still meeting all requirements
More information