LABORATORY TEST AND CALIBRATION EQUIPMENT

Size: px
Start display at page:

Download "LABORATORY TEST AND CALIBRATION EQUIPMENT"

Transcription

1 WATER METER TEST BENCH LABORATORY TEST AND CALIBRATION EQUIPMENT 62

2 WATER METER STATIC PRESSURE TESTING EQUIPMENT Statik Basınç Test Ekipmanı Static Pressure Test Equipment Series: AYSU SBT AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to OIML R49 and EN standards. All of the devices are traceable and it's calibration certified by ISO / IEC Water Meters "Water Pressure Test" Static Pressure Test Equipment TRADEMARK MODEL/TYPE EUROTEST AY-40SPT YEAR 2016 SERIAL NR A test shall be performed, the results of which are capable of demonstrating leakproof performance, equivalent to an applied pressure of at least 1,6 MAP for one minute. (230 V, bar, 6l/min), Meters should be able to show without any breakdown, any leak, infiltration in their walls and permanent deormation when the maximum working pressure for which the meters are enforced continuously and correctly. Test bench is capable of executing the tests detailed in EN Standart Hydraulics pressure is raised up to 1,6 times higher than that of meter (IB highest) and kept in this level for 15 minutes. It is controlled whether there is a physical damage or water leak through outside and display unit in meters. Hydraulics pressure is raised to 2 times of the meter's (IB highest) value and kept in this level for one minute, the flow rate during the examination should be zero. info@euro-met.com.tr 63

3 Loss of Pressure Test Equipment Aysu-Basınç Kaybı Test Cihazı Loss of Pressure Test Equipment Series: AYSU BKT AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to OIML R49 and EN standards. All of the devices are traceable and it's calibration certified by ISO / IEC Water Meters; "Loss of Pressure" Test Testing Equipment TRADEMARK MODEL/TYPE EUROTEST AY40LP YEAR 2016 SERIAL NR The highest loss of pressure should not be above 63 kpa (0,63 bar) under the rated operating conditions (ROC) If the meter has any filter or strainer, these are also evaluated with the meters. The test is completed by measuring the loss of pressure in Q3 flow if the hydrodynamic law which is described as "loss of pressure is proportional to the square ofis determined to be valid for the meter. The equipment is designed to be able to make the loss of pressure test of meters in acordance with related standarts info@euro-met.com.tr

4 WATER METER ENDURANCE (ABRASION) TESTING EQUIPMENT Aysu-Dayanıklılık (Aşındırma) Test Cihazı Endurance (Abrasion) Test Equipment Series: AYSU DT AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to OIML R49 and EN standards. All of the devices are traceable and it's calibration certified by ISO / IEC Water Meter Endurance (Abrasion) Test Bench TRADEMARK MODEL/TYPE EUROTEST AY40ET YEAR 2016 SERIAL NR It is a testing equipment for the test of continuous flow for 100 hours of the Q3 16m3/h meters in T30 and T50 Temperature Classes between DN 15-DN40 in Q4 Test Flow and 20 C Water Temperature Q3 TestFlow with interruptions as X15 seconds It is equipped with Electromagnetic Flow Meter that can show the Q3 and Q4 Test Flows momentarily in ó 02% Measurement Uncertanity Bidirectional Test Band (It is possible to test two different family group meters having equivalence Q3 flow) info@euro-met.com.tr 65

5 HEAT METER DURABILITY TEST EQUIPMENT Isı Sayaçları Dayanıklık(Aşındırma) Test Cihazı Heat meter DurabilityTest Equipment Series: AYSU HDT AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to OIML R75 and EN 1434 standards. All of the devices are traceable and it's calibration certified by ISO / IEC Heat Meter "Durability" Test and Calibration Bench TRADEMARK MODEL/TYPE EUROTEST-40HMD YEAR 2015 SERIAL NR ORIJIN TURKEY (1,5xqi) ± 5 %qp ± 5 % and qs 0-5 %; The basic wear test shall be carried out at the upper limit of the temperature range. After the test the error of indication shall be determined at the flow rates stated in of EN (for the flow sensor) at: For heating aplications (50±5) C or at ( max 0-5) C if max < 50 C. For cooling applications (15±5) C No significant error shall occur. Measurement Range 10 l/h~20m3/h Nominal Diameter DN15~Dn40 Air Temperature 20±5 C Relative Humidity 45~75%,rh 66 info@euro-met.com.tr

6 DOMESTIC WATER METER TEST AND CALIBRATION EQUIPMENT Domestic Water Meters Test and Calibration Bench In the scope of OIML R 49 and TS EN standards, water meters should operate truly in seven distinct flow intervals described below within the allowed error margins. Equipment to make these tests should have k=2ó 02% measurement uncertainty. Structural index error of the meters should be determined by comparing with the real volume in at least seven flows below and making examination in each flow for two times: Between Q1-1, Q1 Between 0,5(Q1 + Q2)-0,55(Q1 + Q2) (if Q2/Q1>1,6), Between Q2-1,1 Q2, Between 0,33(Q2 + Q3)-0,37(Q2 + Q3) Between 0,67(Q2 + Q3)-0,74(Q2 + Q3) Between 0,9 Q3 - Q3 Between 0,95 Q4 - Q4 info@euro-met.com.tr 67

7 WOLTMAN WATER METER TESTING EQUIPMENT AYSU WTB200 AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to OIML R49 and EN standards. All of the devices are traceable and it's calibration certified by ISO / IEC WOLTMAN WATER METER TEST AND CALIBRATION BENCH SPECIFICATION TRADEMARK MODEL/TYPE AYTEST-W300SE YEAR 2014 SERIAL NR. 2016W Nominal Diameter DN50~300 Test Line Capacity 1 to 3 Meter Test Line Sensitivity D5 Test Line Sensitivity U15 Minimum Flowrate, 100l/h Overload Flowrate, 1000 m 3 /h Referans Temperature 20 C Water Pressure Classes MAP16 In the scope of (MID) Council directive 2004/22/EC, OIML R 49 and TS EN standards, water meters should operate truly in seven distinct flow intervals described below within the allowed error margins. Equipment to make these tests should have k=2 0,2% measurement uncertainty. Structural index error of the meters should be determined by comparing with the real volume in at least seven flows below and making examination in each flow for two times: Between Q1-1,1 Q1, Between 0,5 (Q1 + Q2) -0,55 (Q1 + Q2) (if Q2/ Q1 > 1,6), Between Q2-1,1 Q2, Between 0,33 (Q2 + Q3)- 0,37 (Q2 + Q3), Between 0,67 (Q2 + Q3) -0,74 (Q2 + Q3), Between 0,9 Q3 - Q3, Between 0,95 Q4 - Q info@euro-met.com.tr

8 HEAT METER TEST AND CALIBRATION EQUIPMENT AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to 2014/32/ EU (MID), OIML R75 and EN 1434 standards. All of the devices are traceable and it's calibration certified by ISO / IEC Heat Meter Test and Calibration Bench In the scope of (MID) Council directive 2004/22/EC, OIML R 75 and EN 1434 standards, water meters should operate truly in seven distinct flow intervals described below within the allowed error margins. Equipment to make these tests should have k=2 0,2% measurement uncertainty. Structural index error of the meters should be determined by comparing with the real volume in at least seven flows below and making examination in each flow for two times: Complete meter The verification of the complete meter shall be carried out, at least within each of the following ranges For heating applications: a) Δ0min Δ 1,2 Δ0min and 0,9 qp q qp b) 10 K Δ 20 K and 0,1 qp q 0,11 qp c) Δ max - 5 K Δ Δ0max and qi q 1,1 qi SPECIFIC REQUIREMENTS Rated operating conditions The values of the rated operating conditions shall be specified by the manufacturer as follows: 1.1. For the temperature of the liquid: max, min, for the temperature differences: Δ max, Δ min, subject to the following restrictions: Δ max/δ min 10; Δ min = 3 K or 5 K or 10 K For the pressure of the liquid: The maximum positive internal pressure that the heat meter can withstand permanently at the upper limit of the temperature For the flow rates of the liquid: qs, qp, qi, where the values of qp and qi are subject to the following restriction: qp/qi For the thermal power: Ps. info@euro-met.com.tr 69

9 AYSU LABORATORY TEST EQUIPMENT AYSU LABORATORY TEST EQUIPMENT AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to OIML R49, 75 and R120; EN and EN 1434 standards. All of the devices are traceable and it's calibration certified by ISO / IEC *Domestic Water Meter Test and Calibration Bench *Woltman Water meter Test and Calibration Bench *Heat Meter Test and Calibration Bench *Test Measure for to Fuel Dispenser and Tanker Meter *Energy Meter Test Bench 70 info@euro-met.com.tr

10 AMR SYSTEM AND ALL PRODUCTS 71

11 Bu katalog kosgeb desteği ile basılmıştır. Basım Tarihi: 27 Nisan 2016 BETİMOFSET / studyo@superonline.com Ölçü Aletleri Lab. ve Test Ekip.Dan.İmalat San.Tic.Ltd.Şti. Anadolu Bulvarı ATB İş Merkezi C Blok No:84 Yenimahalle - Ankara / TÜRKİYE - 16 F: info@euro-met.com.tr

Organisation Internationale de Métrologie Légale. Direct mass flow measuring systems for quantities of liquids Annex C: Test report format

Organisation Internationale de Métrologie Légale. Direct mass flow measuring systems for quantities of liquids Annex C: Test report format Organisation Internationale de Métrologie Légale OIML INTERNATIONAL RECOMMENDATION Direct mass flow measuring systems for quantities of liquids Annex C: Test report format Ensembles de mesurage massiques

More information

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities Specific Accreditation Criteria Calibration ISO IEC 17025 Annex Mass and related quantities January 2018 Copyright National Association of Testing Authorities, Australia 2014 This publication is protected

More information

pren CEN standard-draft pr EN 12261

pren CEN standard-draft pr EN 12261 CEN standard-draft pr EN 12261 CEN standard-draft according to engl version from 06/1998 Meter Classification Pressure ratings, gas meter sizes, dimensions, temperature ranges Metrological performance

More information

INTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

INTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION INTERNATIONAL OIML R 32 RECOMMENDATION Edition 1989 (E) Rotary piston gas meters and turbine gas meters Compteurs de volume de gaz à pistons rotatifs et compteurs de volume de gaz à turbine OIML R 32 Edition

More information

Mass Flowmeters. Mass Flowmeters for Gases

Mass Flowmeters. Mass Flowmeters for Gases Mass Flowmeters Mass Flowmeters for Gases Fast, Accurate, Low Pressure Drop for critical measurement applications! Flow (Std l/min) Response to a step change in flowrate 300 200 100 4 Milliseconds 63%

More information

PRESSURE TRANSDUCERS WITH UNIFIED (4-20) ma OR (10-50) ma OUTPUT SIGNAL

PRESSURE TRANSDUCERS WITH UNIFIED (4-20) ma OR (10-50) ma OUTPUT SIGNAL PRESSURE TRANSDUCERS WITH UNIFIED (4-0) ma OR (10-50) ma OUTPUT SIGNAL 4 th Draft OIML Recommendation TC10-SC1 English version 4.0 Prepared by: Mgr. Jiří Tesař, PhD., Mgr. Dominik Pražák Pressure Department

More information

SonoSelect 10 and SonoSafe 10 energy meters

SonoSelect 10 and SonoSafe 10 energy meters SonoSelect 10 and SonoSafe 10 energy meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

JOS 15 JOS 25 JOS 40. Manual and semiautomatic test benches from DN 25 to DN 40. Characteristics. Basic characteristics. Test bench using balances

JOS 15 JOS 25 JOS 40. Manual and semiautomatic test benches from DN 25 to DN 40. Characteristics. Basic characteristics. Test bench using balances TEST BENCHES JOS 15 JOS 25 JOS 40 Manual and semiautomatic test benches from DN 25 to DN 40 02 Characteristics Compact test benches - all in one room Designation - for residential and apartment meters

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

UNDERSTANDING, ACCELERATED

UNDERSTANDING, ACCELERATED UNDERSTANDING, ACCELERATED MEASURE FLOW, PRESSURE, AND TEMPERATURE ALL IN ONE INSTRUMENT! Designed for Performance TSI thermal mass flowmeters incorporate a proprietary platinum film sensor design for

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

GMC-I Service GmbH Calibration Center

GMC-I Service GmbH Calibration Center 2016 GMC-I Service GmbH Calibration Center DAkkS, ISO & Factorycalibration www.gmci-service.com From spare parts, reparation, rental service, maintenance of industrial health and safety standards, calibration

More information

Organisation Internationale de Métrologie Légale

Organisation Internationale de Métrologie Légale Organisation Internationale de Métrologie Légale OIML INTERNATIONAL RECOMMENDATION Pressure balances Manomètres à piston OIML R 110 Edition 1994 (E) CONTENTS Foreword... 3 1 Scope... 4 2 Terminology...

More information

FPG8601 Force Balanced Piston Gauge

FPG8601 Force Balanced Piston Gauge FPG8601 Force Balanced Piston Gauge Reference Level Calibration System for very low pressure Pressure range: 0 to 15 kpa gauge, absolute and absolute differential Standard resolution: 0.010 Pa, high resolution

More information

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.

TRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Volumeter TRZ 0-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Turbine Gas Flowmeter continues the tradition of Honeywell s field-proven turbine meter technology, delivering

More information

United Kingdom of Great Britain and Northern Ireland

United Kingdom of Great Britain and Northern Ireland (UK/0126/0074) MI-005 United Kingdom of Great Britain and Northern Ireland Certificate of EC type-examination of a measuring instrument Number: UK/0126/0074 issued by the Secretary of State for Business,

More information

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)

CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34) CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE (+34) 968 162 005 www.sensovant.com comercial@sensovant.com www.epluse.com CALIBRATION AT THE HIGHEST LEVEL The

More information

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated. Asset #: 123 Calibration - Certificate No: 2083.01 Customer: Condition: Action Taken: Sample Inc. 123 Sample Rd. Sample, MA 01234 The instrument was operational upon receipt. The instrument was adjusted

More information

CTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration

CTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration CTAG:ebdaf8e87fbb5996aefb9 Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 6858 Instrument Description Manufacturer Model Serial Number Inventory Number CABLE ANALYZER FLUKE NETWORKS DTX-8

More information

United Kingdom of Great Britain and Northern Ireland

United Kingdom of Great Britain and Northern Ireland (UK/0126/0026) MI-005 United Kingdom of Great Britain and Northern Ireland Certificate of EC type-examination of a measuring instrument Number: UK/0126/0065 issued by the Secretary of State for Business,

More information

TESTING BENCHES for watermeters

TESTING BENCHES for watermeters TESTING BENCHES for watermeters +372 6 480 235 Haljas tee 25, 12012 TALLINN Fax +372 6 480 125 Testing benches are designed by Tepso Ltd. for using in calibration laboratories and also in watermeter production

More information

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website:  Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

Technical Information Conducal CLY421

Technical Information Conducal CLY421 TI00496C/07/EN/01.12 71142150 Products Solutions Services Technical Information Conducal CLY421 Conductivity calibration set for ultrapure water applications Factory calibrated measurement box Certified

More information

CTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration

CTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration CTAG:b997e6abfa98cebb6b Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 79 Instrument Description Manufacturer Model Serial Number Inventory Number CABLE ANALYZER FLUKE NETWORKS DTX-8

More information

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1 HANDBOOK Ed. 2017 DS-ED 01/2017 - ENG 1 CHAPTER 9 BURSTING DISC DEVICES IN SERIES 3070 SCOPE Use: protection against possible overpressure of the apparatuses listed below, with regard to the operating

More information

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER

METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER 1250 METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER 1.0 Scope and Application. 1.1 Analytes. Analyte CAS No. Sensitivity Total Organic Compounds N/A

More information

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy. Bulletin Category: GAS Bulletin: G-23 Page: 1 of 7 The copy of this document located on Measurement Canada s website is considered to be the controlled copy. Recognition of data from specialty gas suppliers

More information

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0 High Accuracy Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

Certified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS

Certified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS Certified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS Regular verification of laboratory instrumentation is of primary importance in a modern manufacturing facility, not only for reasons of

More information

ali-q TM Gravimetric Verification Procedure

ali-q TM Gravimetric Verification Procedure ali-q TM Gravimetric Verification Procedure Introduction This document describes the recommended procedure for verifying performance of the ali-q aliquoting pipet controller using the industry standard-

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

NMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013

NMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013 NMISA NEW GAS FLOW CALIBRATION FACILITY Deona Jonker 7 October 2013 Introduction Flow the total volume of a fluid that flows past a fixed point in a given time Flow measurements used in industry as a means

More information

Automatic Isokinetic Sampler. ST5 Evo

Automatic Isokinetic Sampler. ST5 Evo Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,

More information

Pressure is our Business

Pressure is our Business Pressure is our Business Count on gauges and calibrators that perform Wherever you work Reduce Measurement Error Protect against diminished accuracy from environmental conditions, accidental damage, and

More information

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

Beamex. Calibration White Paper.  Weighing scale calibration - How to calibrate weighing instruments Beamex Calibration White Paper info@beamex.com Weighing scale calibration - How to calibrate weighing instruments Weighing scale calibration - How to calibrate weighing instruments Weighing scales, weighing

More information

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor.  Type: ETd 04. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)

Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA) Int. J. Metrol. Qual. Eng. 5, 303 (2014) c EDP Sciences 2014 DOI: 10.1051/ijmqe/2014012 Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA) D. Jonker and E.P. Tarnow

More information

Light Lab. Reliable Measurements through Regular Calibration. DAkkS

Light Lab. Reliable Measurements through Regular Calibration. DAkkS Light Lab Reliable Measurements through Regular Calibration QM DAkkS ARS 85 EYREIENCEG QM EXP Benefits of Calibration PERFECTION THROUGH CALIBRATION RIN EASU HT M OLOGY IG L IN ECHN T LEGAL CERTAINTY Avoidance

More information

KENYA ACCREDITATION SERVICE

KENYA ACCREDITATION SERVICE KENAS-GUD-016 01 16/03/2013 16 / 04/2013 GUD Page 1 of 18 Approval and Authorisation Completion of the following signature blocks signifies the review and approval of this Document. Name Job Title / Role

More information

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT

General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (09) 64 R5 QUALIFICATION OF EQUIPMENT ANNEX 6: QUALIFICATION OF PISTON PIPETTES Full document title and reference Document type

More information

CALIBRATION CERTIFICATE # 500

CALIBRATION CERTIFICATE # 500 CALIBRATION CERTIFICATE # 5 Calibration date : -- Certificate issued : --8 Company name Company address City, Province, Canada CLAS 9- Calibration of Mass flow meter Brooks SLA585S S/N : ABCD QUALITY PROGRAM

More information

National Health Service Model engineering Specification

National Health Service Model engineering Specification National Health Service Model engineering Specification D 08 Thermostatic mixing valves (Healthcare premises) Issue date: Issue 4 Page 2 Contents Page No 0. Introduction 4 1. Scope 4 2. Definitions 6 3.

More information

NMISA New Gas Flow Calibration Facility

NMISA New Gas Flow Calibration Facility NMISA New Gas Flow Calibration Facility Speaker / Author: D. Jonker Co-author: E.P. Tarnow National Metrology Institute of South Africa (NMISA) Private Bag X34, Lynnwood Ridge, Pretoria, 0040, South Africa

More information

EN ISO/IEC Technical Requirements

EN ISO/IEC Technical Requirements EN ISO/IEC 17025 - Technical Requirements Wolfgang Garche Environmental Protection Agency Department Air Quality Monitoring, Information, Assessment 1 What means accreditation in accordance to EN ISO/IEC

More information

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience - Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience - Dr. Wolfgang Jockel, Martin Schneider, TÜV Rheinland Group, D-51105 Cologne / Germany 1. Introduction A new basis for the certification

More information

Towards ISO Koos van Helden, B.ASc. International Account Manager Eastern Hemisphere mailto:

Towards ISO Koos van Helden, B.ASc. International Account Manager Eastern Hemisphere mailto: Towards ISO 17089-1 Koos van Helden, B.ASc. International Account Manager Eastern Hemisphere mailto: koos.vanhelden@kpnmail.nl Who am I? My name: Koos van Helden International Account Manager Eastern Hemisphere

More information

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN

PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN METRIC 17 May 2013 SUPERSEDING MIL-PRF-27201D 07 February 2007 PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN This specification is approved for use by all Departments and Agencies of the Department of

More information

ISO 3724 INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using particulate contaminant

ISO 3724 INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using particulate contaminant INTERNATIONAL STANDARD ISO 3724 Second edition 2007-08-15 Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using particulate contaminant Transmissions hydrauliques Éléments

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

ZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids

ZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids www.kem-kueppers.com Technical Datasheet ZHM ST Series Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids Certified zertifiziert according gemäß to DIN DIN EN EN ISO ISO 9001

More information

OIML R 140 RECOMMENDATION. Edition 2007 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Measuring systems for gaseous fuel

OIML R 140 RECOMMENDATION. Edition 2007 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Measuring systems for gaseous fuel INTERNATIONAL RECOMMENDATION OIML R 140 Edition 2007 (E) Measuring systems for gaseous fuel Systèmes de mesurage de gaz OIML R 140 Edition 2007 (E) ORGANISATION INTERNATIONALE DE MÉTROLOGIE LÉGALE INTERNATIONAL

More information

EC type-examination certificate UK/0126/0065 Revision 1

EC type-examination certificate UK/0126/0065 Revision 1 UK/0126/0065 MI-005 EC type-examination certificate UK/0126/0065 Revision 1 issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments

More information

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid

COMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid Volumetric flow Compressed Air Mass flow Gas Net volumetric flow Steam Liquid Universal compact orifice flow meter combines a compact orifice flow sensor and sotiphicated converter One-piece flow sensor,

More information

White Paper August , Rev AA

White Paper August , Rev AA Section 1 Automatic Tank Gauging in Custody Transfer Applications Abstract Today Automatic Tank Gauges (ATG s) are commonly used world wide for custody transfer of petroleum products. International standards

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 8655-4 First edition 2002-09-15 Piston-operated volumetric apparatus Part 4: Dilutors Appareils volumétriques à piston Partie 4: Diluteurs Reference number ISO 8655-4:2002(E)

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Metering Code Gas TSO, measurement by connected party Effective from to the present

Metering Code Gas TSO, measurement by connected party Effective from to the present Please note that although Gasunie Transport Services B.V. translated the Dutch network codes with utmost care, Gasunie Transport Services B.V. would like to point out that only the decisions of the Dutch

More information

LM LUMEN MAINTENANCE TEST REPORT

LM LUMEN MAINTENANCE TEST REPORT Version: B LM-80-08 LUMEN MAINTENANCE TEST REPORT Company :UNISTARS Corporation Ltd. Sample Name :VENUS 3535 Sample Received :May 29 2012 Sample Tested :Feb 14 2013 TESTING LABORATORY IS ACCREDITED BY:

More information

Particulate Emission Monitor Correlation. Camden Power Station Stack No RSL152

Particulate Emission Monitor Correlation. Camden Power Station Stack No RSL152 Particulate Emission Monitor Correlation Camden Power Station Stack No. 3 2011 P.O. Box 2459 Noordheuwel ext 4 Krugersdorp 1756 Vat No. 4670254459 STACKLABS ENVIRONMENTAL SERVICES 10 Chisel Street Boltonia

More information

Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices

Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices Status as of 2014-01 Principles of testing Insulating hose assemblies on cable cutting devices

More information

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter

Technical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter Technical Data Sheet KROHNE 12/2004 7.02516.21.00 CH/GR OPTIMASS 7000 Custody Transfer Mass Flowmeter with single straight measuring tube OIML R117 Pattern Approval Accuracy classes 0.3 / 0.5 / 1.0 / 1.5

More information

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1 High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

STAINLESS STEEL OVERFLOW VALVE TYPE 417

STAINLESS STEEL OVERFLOW VALVE TYPE 417 MAIN CHARACTERISTICS The 417 valve is intended for the discharge of fluids overflow when an upstream limitation of pressure is looked for, for example downstream to a pump. This valve also works in presence

More information

Ships tank - General requirements

Ships tank - General requirements INTERNATIONAL OIML R 95 RECOMMENDATION Edition 1990 (E) Ships tank - General requirements Bateaux-citernes - Prescriptions générales OIML R 95 Edition 1990 (E) ORGANISATION INTERNATIONALE DE MÉTROLOGIE

More information

Specification For Water Meters. Pr10068

Specification For Water Meters. Pr10068 Specification For Water Meters Pr10068 Documents Details This document is only valid on the day it was printed. Version Review Revision Date issued Reviewed by Approved by Date approved Revision type 0.1

More information

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL

Improved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL Improved Reliability in Natural Gas Energy Measurement with the Revised ISO 10723 Standard Gerard Nieuwenkamp - VSL Improved reliability in natural gas energy measurement with the revised ISO 10723 standard

More information

Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media

Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media www.kem-kueppers.com Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media Certified zertifiziert according gemäß to DIN DIN EN EN ISO ISO 9001 9001 2

More information

General Accreditation Guidance. User checks and maintenance of laboratory balances

General Accreditation Guidance. User checks and maintenance of laboratory balances General Accreditation Guidance User checks and maintenance of laboratory balances January 2018 Copyright National Association of Testing Authorities, Australia 2010 All intellectual property rights in

More information

Technical Procedure for General Laboratory Equipment

Technical Procedure for General Laboratory Equipment Technical Procedure for General Laboratory Equipment 1.0 Purpose - This procedure specifies the required elements for the use of general laboratory equipment. 2.0 Scope - This procedure applies to all

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid INTERNATIONAL STANDARD ISO 23181 First edition 2007-08-15 Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid Transmissions hydrauliques Éléments

More information

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.

INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION. Andrzej Hantz RADWAG BALANCES AND SCALES INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION. The article presents the influence of comparison process automatization

More information

Pressure Metrology in Mexico

Pressure Metrology in Mexico Pressure Metrology in Mexico Jorge C. TORRES G., Benjamin SORIANO C. and Victor ARANDA C. Centro Nacional de Metrologia-CENAM km 4,5 Carretera a Los Cues, El Marques, Queretaro, MEXICO e-mail: jorge.torres@cenam.mx

More information

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)

A Rationale for Pressure Relief Device(s) Qualification Requirements (LH2) UN-GTR PART A INSERTION Stand 09.02.2011, 17:20 Uhr A.3.3 HYDROGEN STORAGE SYSTEM The hydrogen storage system consists of all components that form the primary pressure boundary of the stored hydrogen in

More information

Calibration Summary of Test Report No.: Sample

Calibration Summary of Test Report No.: Sample Calibration Summary of Test Report No.:30043 Rion Type: NL52/EX Serial no: 00732122 Customer: Scantek, Inc. Address: 6430 Dobbin Rd., Suite C, Columbia MD, 21045 Contact Person: Mariana Buzduga Phone No.:

More information

Materials : Stainless steel ASTM A351 CF8M

Materials : Stainless steel ASTM A351 CF8M Certificat 3.1 Size: Ends : Min Temperature : Max Temperature : DN 15 to DN 200 PN16 Flanges R.F. - 20 C + 200 C Max Pressure : 16 Bars Specifiations : Removable stainless steel filter Bolted bonnet with

More information

Road and rail tankers with level gauging Part 2 Metrological controls and tests. Page 1 of 42 OIML TC8/SC1/WG3/R 80-2 CD1 Draft of July

Road and rail tankers with level gauging Part 2 Metrological controls and tests. Page 1 of 42 OIML TC8/SC1/WG3/R 80-2 CD1 Draft of July Page 1 of 42 OIML TC8/SC1/WG3 Circulated to Members of OIML TC8/SC1/WG3 Title Revision R 80-2 Road and rail tankers with level gauging. Metrological controls and tests Discussion by e-mail and at the meeting

More information

Rotary valves HRB 3, HRB 4

Rotary valves HRB 3, HRB 4 Data sheet Rotary valves HRB 3, HRB 4 Description HRB rotary valves can be used in combination with electric actuators AMB 162 and AMB 182. Features: Lowest leakage in class Unique position indicator (visible

More information

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel KROHNE 04/2003 7.02445.71.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel One tube no limits No limits with tube material No limits with

More information

Electronic Volume Correctors

Electronic Volume Correctors Electronic Volume Correctors Ben Manson Landis+Gyr October 14, 2016 PUBLIC Agenda Customer Types and suitable equipment Volume corrector standards / regulations Basics of volume correction Gauge v Absolute

More information

BS12N Piezoresistive OEM Pressure Sensor

BS12N Piezoresistive OEM Pressure Sensor BS12N Piezoresistive OEM Pressure Sensor Model: BS12N-1 Model: BS12N-2 Feature Pressure range (-0.1~60)Mpa; Pressure reference: Gauge, absolute and sealed gauge; Constant current power supply; Isolated

More information

Model 601CV. Mass Flow Controller. Product Features:

Model 601CV. Mass Flow Controller. Product Features: Model 601CV Mass Flow Controller Porter s Model 601CV Series II Mass Flow Controller (MFCs) is designed for precise control of virtually all conventional process gases. The MFC consists of a thermal mass

More information

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in

More information

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma

More information

Bursting strength of paper. 1. Scope

Bursting strength of paper. 1. Scope T 403 om-97 OFFICIAL STANDARD 1926 TENTATIVE STANDARD 1952 OFFICIAL STANDARD 1974 CORRECTED 1976 OFFICIAL TEST METHOD 1985 CORRECTED 1985 REVISED 1991 REVISED 1997 1997 TAPPI The information and data contained

More information

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions

Continuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions Continuous Gas Analysis In situ laser gas analyzers Compact Operating Instructions 1 LDS 6 TÜV/MCERTS certified analyzers for NH3/H2O, NH3 and H2O 1.1 Operation requirements Please observe the following:

More information

OIML R 126 RECOMMENDATION. Edition 1998 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Evidential breath analyzers DE MÉTROLOGIE LÉGALE

OIML R 126 RECOMMENDATION. Edition 1998 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Evidential breath analyzers DE MÉTROLOGIE LÉGALE INTERNATIONAL RECOMMENDATION OIML R 126 Edition 1998 (E) Evidential breath analyzers Éthylomètres OIML R 126 Edition 1998 (E) ORGANISATION INTERNATIONALE DE MÉTROLOGIE LÉGALE INTERNATIONAL ORGANIZATION

More information

Application Note AN-107

Application Note AN-107 SPEC Sensor TM Characterization & Calibration Considerations Scope This document is provided to describe the considerations needed to characterize, calibrate, verify and validate the measurement performance

More information

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?

Chapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service? Pipette specifications according to ISO 8655 Chapter 5 5.1 The ISO 8655 standard gives the accuracy and precision limits as both absolute and relative values. Specifications will depend on the technique

More information

Technote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits.

Technote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits. Page 1 of 15 - Dynamic Pressure and Regulation Valve Application system can be installed in domestic and commercial heating and cooling systems. system is a dynamic valve arrangement designed to regulate

More information

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

Seated valve for steam (PN 25) VFS 2 2-way valve, flange Data sheet Seated valve for steam (PN 25) VFS 2 2-way valve, flange Description VFS 2 valve is a range of 2 port flanged valve for chilled water, PHW, MPHW, HPHW (low, medium or high pressure hot water)

More information

Standard Operating Procedure Measuring & Testing Equipment

Standard Operating Procedure Measuring & Testing Equipment Standard Operating Procedure Measuring & Testing Equipment Purpose: 7.6 Responsibility: 7.6d Scope To have a procedure to ensure that all is controlled, maintained and calibrated to ensure that Product

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CAPSTONE CALIBRATION 7016 Baker Blvd Richland Hills, TX 76118 Jon T. Cappa Phone: 817 284 2707 CALIBRATION Valid To: January 31, 2020

More information

Informal document regarding progress of CEN standards for reference in RID/ADR

Informal document regarding progress of CEN standards for reference in RID/ADR Joint Meeting of the RID Safety Committee and the Working Party on the Transport of Dangerous Goods (Berne, 13-24 March 2000) Informal document regarding progress of CEN standards for reference in RID/ADR

More information

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)

Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G) Institut fédéral de métrologie METAS METAS-N001/EN Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T (15 000 G) This document is a translation

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PRECISION MEASURING CORP Groesbeck Hwy. Fraser, MI Robert Meyer Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PRECISION MEASURING CORP Groesbeck Hwy. Fraser, MI Robert Meyer Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 PRECISION MEASURING CORP. 33250 Groesbeck Hwy. Fraser, MI 48026 Robert Meyer Phone: 586 293 4420 CALIBRATION Valid To: September 30, 2019 Certificate Number:

More information

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass Introduction Fig. 1 Basic version - A Fig. * Self-acting version with automatic disinfection function - B * thermometer is an accessory

More information

Digital pressure gauge Model CPG500

Digital pressure gauge Model CPG500 Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 for further approvals see page 3 Applications Calibration service companies and service industry Measurement and control laboratories Quality

More information

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas Vortex Flow Meter Wafer or Flange Connection - Steam - Liquid - Gas Working Principle & Circuit Diagram Working Principle When a column body placed in flowing fluids in pipe, a series of vortices will

More information