LABORATORY TEST AND CALIBRATION EQUIPMENT
|
|
- Alexis Nichols
- 5 years ago
- Views:
Transcription
1 WATER METER TEST BENCH LABORATORY TEST AND CALIBRATION EQUIPMENT 62
2 WATER METER STATIC PRESSURE TESTING EQUIPMENT Statik Basınç Test Ekipmanı Static Pressure Test Equipment Series: AYSU SBT AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to OIML R49 and EN standards. All of the devices are traceable and it's calibration certified by ISO / IEC Water Meters "Water Pressure Test" Static Pressure Test Equipment TRADEMARK MODEL/TYPE EUROTEST AY-40SPT YEAR 2016 SERIAL NR A test shall be performed, the results of which are capable of demonstrating leakproof performance, equivalent to an applied pressure of at least 1,6 MAP for one minute. (230 V, bar, 6l/min), Meters should be able to show without any breakdown, any leak, infiltration in their walls and permanent deormation when the maximum working pressure for which the meters are enforced continuously and correctly. Test bench is capable of executing the tests detailed in EN Standart Hydraulics pressure is raised up to 1,6 times higher than that of meter (IB highest) and kept in this level for 15 minutes. It is controlled whether there is a physical damage or water leak through outside and display unit in meters. Hydraulics pressure is raised to 2 times of the meter's (IB highest) value and kept in this level for one minute, the flow rate during the examination should be zero. info@euro-met.com.tr 63
3 Loss of Pressure Test Equipment Aysu-Basınç Kaybı Test Cihazı Loss of Pressure Test Equipment Series: AYSU BKT AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to OIML R49 and EN standards. All of the devices are traceable and it's calibration certified by ISO / IEC Water Meters; "Loss of Pressure" Test Testing Equipment TRADEMARK MODEL/TYPE EUROTEST AY40LP YEAR 2016 SERIAL NR The highest loss of pressure should not be above 63 kpa (0,63 bar) under the rated operating conditions (ROC) If the meter has any filter or strainer, these are also evaluated with the meters. The test is completed by measuring the loss of pressure in Q3 flow if the hydrodynamic law which is described as "loss of pressure is proportional to the square ofis determined to be valid for the meter. The equipment is designed to be able to make the loss of pressure test of meters in acordance with related standarts info@euro-met.com.tr
4 WATER METER ENDURANCE (ABRASION) TESTING EQUIPMENT Aysu-Dayanıklılık (Aşındırma) Test Cihazı Endurance (Abrasion) Test Equipment Series: AYSU DT AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to OIML R49 and EN standards. All of the devices are traceable and it's calibration certified by ISO / IEC Water Meter Endurance (Abrasion) Test Bench TRADEMARK MODEL/TYPE EUROTEST AY40ET YEAR 2016 SERIAL NR It is a testing equipment for the test of continuous flow for 100 hours of the Q3 16m3/h meters in T30 and T50 Temperature Classes between DN 15-DN40 in Q4 Test Flow and 20 C Water Temperature Q3 TestFlow with interruptions as X15 seconds It is equipped with Electromagnetic Flow Meter that can show the Q3 and Q4 Test Flows momentarily in ó 02% Measurement Uncertanity Bidirectional Test Band (It is possible to test two different family group meters having equivalence Q3 flow) info@euro-met.com.tr 65
5 HEAT METER DURABILITY TEST EQUIPMENT Isı Sayaçları Dayanıklık(Aşındırma) Test Cihazı Heat meter DurabilityTest Equipment Series: AYSU HDT AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to OIML R75 and EN 1434 standards. All of the devices are traceable and it's calibration certified by ISO / IEC Heat Meter "Durability" Test and Calibration Bench TRADEMARK MODEL/TYPE EUROTEST-40HMD YEAR 2015 SERIAL NR ORIJIN TURKEY (1,5xqi) ± 5 %qp ± 5 % and qs 0-5 %; The basic wear test shall be carried out at the upper limit of the temperature range. After the test the error of indication shall be determined at the flow rates stated in of EN (for the flow sensor) at: For heating aplications (50±5) C or at ( max 0-5) C if max < 50 C. For cooling applications (15±5) C No significant error shall occur. Measurement Range 10 l/h~20m3/h Nominal Diameter DN15~Dn40 Air Temperature 20±5 C Relative Humidity 45~75%,rh 66 info@euro-met.com.tr
6 DOMESTIC WATER METER TEST AND CALIBRATION EQUIPMENT Domestic Water Meters Test and Calibration Bench In the scope of OIML R 49 and TS EN standards, water meters should operate truly in seven distinct flow intervals described below within the allowed error margins. Equipment to make these tests should have k=2ó 02% measurement uncertainty. Structural index error of the meters should be determined by comparing with the real volume in at least seven flows below and making examination in each flow for two times: Between Q1-1, Q1 Between 0,5(Q1 + Q2)-0,55(Q1 + Q2) (if Q2/Q1>1,6), Between Q2-1,1 Q2, Between 0,33(Q2 + Q3)-0,37(Q2 + Q3) Between 0,67(Q2 + Q3)-0,74(Q2 + Q3) Between 0,9 Q3 - Q3 Between 0,95 Q4 - Q4 info@euro-met.com.tr 67
7 WOLTMAN WATER METER TESTING EQUIPMENT AYSU WTB200 AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to OIML R49 and EN standards. All of the devices are traceable and it's calibration certified by ISO / IEC WOLTMAN WATER METER TEST AND CALIBRATION BENCH SPECIFICATION TRADEMARK MODEL/TYPE AYTEST-W300SE YEAR 2014 SERIAL NR. 2016W Nominal Diameter DN50~300 Test Line Capacity 1 to 3 Meter Test Line Sensitivity D5 Test Line Sensitivity U15 Minimum Flowrate, 100l/h Overload Flowrate, 1000 m 3 /h Referans Temperature 20 C Water Pressure Classes MAP16 In the scope of (MID) Council directive 2004/22/EC, OIML R 49 and TS EN standards, water meters should operate truly in seven distinct flow intervals described below within the allowed error margins. Equipment to make these tests should have k=2 0,2% measurement uncertainty. Structural index error of the meters should be determined by comparing with the real volume in at least seven flows below and making examination in each flow for two times: Between Q1-1,1 Q1, Between 0,5 (Q1 + Q2) -0,55 (Q1 + Q2) (if Q2/ Q1 > 1,6), Between Q2-1,1 Q2, Between 0,33 (Q2 + Q3)- 0,37 (Q2 + Q3), Between 0,67 (Q2 + Q3) -0,74 (Q2 + Q3), Between 0,9 Q3 - Q3, Between 0,95 Q4 - Q info@euro-met.com.tr
8 HEAT METER TEST AND CALIBRATION EQUIPMENT AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to 2014/32/ EU (MID), OIML R75 and EN 1434 standards. All of the devices are traceable and it's calibration certified by ISO / IEC Heat Meter Test and Calibration Bench In the scope of (MID) Council directive 2004/22/EC, OIML R 75 and EN 1434 standards, water meters should operate truly in seven distinct flow intervals described below within the allowed error margins. Equipment to make these tests should have k=2 0,2% measurement uncertainty. Structural index error of the meters should be determined by comparing with the real volume in at least seven flows below and making examination in each flow for two times: Complete meter The verification of the complete meter shall be carried out, at least within each of the following ranges For heating applications: a) Δ0min Δ 1,2 Δ0min and 0,9 qp q qp b) 10 K Δ 20 K and 0,1 qp q 0,11 qp c) Δ max - 5 K Δ Δ0max and qi q 1,1 qi SPECIFIC REQUIREMENTS Rated operating conditions The values of the rated operating conditions shall be specified by the manufacturer as follows: 1.1. For the temperature of the liquid: max, min, for the temperature differences: Δ max, Δ min, subject to the following restrictions: Δ max/δ min 10; Δ min = 3 K or 5 K or 10 K For the pressure of the liquid: The maximum positive internal pressure that the heat meter can withstand permanently at the upper limit of the temperature For the flow rates of the liquid: qs, qp, qi, where the values of qp and qi are subject to the following restriction: qp/qi For the thermal power: Ps. info@euro-met.com.tr 69
9 AYSU LABORATORY TEST EQUIPMENT AYSU LABORATORY TEST EQUIPMENT AYSU is a registered trademark and trademark assurance and manufactured with advanced technology and unique design according to OIML R49, 75 and R120; EN and EN 1434 standards. All of the devices are traceable and it's calibration certified by ISO / IEC *Domestic Water Meter Test and Calibration Bench *Woltman Water meter Test and Calibration Bench *Heat Meter Test and Calibration Bench *Test Measure for to Fuel Dispenser and Tanker Meter *Energy Meter Test Bench 70 info@euro-met.com.tr
10 AMR SYSTEM AND ALL PRODUCTS 71
11 Bu katalog kosgeb desteği ile basılmıştır. Basım Tarihi: 27 Nisan 2016 BETİMOFSET / studyo@superonline.com Ölçü Aletleri Lab. ve Test Ekip.Dan.İmalat San.Tic.Ltd.Şti. Anadolu Bulvarı ATB İş Merkezi C Blok No:84 Yenimahalle - Ankara / TÜRKİYE - 16 F: info@euro-met.com.tr
Organisation Internationale de Métrologie Légale. Direct mass flow measuring systems for quantities of liquids Annex C: Test report format
Organisation Internationale de Métrologie Légale OIML INTERNATIONAL RECOMMENDATION Direct mass flow measuring systems for quantities of liquids Annex C: Test report format Ensembles de mesurage massiques
More informationSpecific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities
Specific Accreditation Criteria Calibration ISO IEC 17025 Annex Mass and related quantities January 2018 Copyright National Association of Testing Authorities, Australia 2014 This publication is protected
More informationpren CEN standard-draft pr EN 12261
CEN standard-draft pr EN 12261 CEN standard-draft according to engl version from 06/1998 Meter Classification Pressure ratings, gas meter sizes, dimensions, temperature ranges Metrological performance
More informationINTERNATIONAL OIML R 32 RECOMMENDATION. Rotary piston gas meters and turbine gas meters ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION
INTERNATIONAL OIML R 32 RECOMMENDATION Edition 1989 (E) Rotary piston gas meters and turbine gas meters Compteurs de volume de gaz à pistons rotatifs et compteurs de volume de gaz à turbine OIML R 32 Edition
More informationMass Flowmeters. Mass Flowmeters for Gases
Mass Flowmeters Mass Flowmeters for Gases Fast, Accurate, Low Pressure Drop for critical measurement applications! Flow (Std l/min) Response to a step change in flowrate 300 200 100 4 Milliseconds 63%
More informationPRESSURE TRANSDUCERS WITH UNIFIED (4-20) ma OR (10-50) ma OUTPUT SIGNAL
PRESSURE TRANSDUCERS WITH UNIFIED (4-0) ma OR (10-50) ma OUTPUT SIGNAL 4 th Draft OIML Recommendation TC10-SC1 English version 4.0 Prepared by: Mgr. Jiří Tesař, PhD., Mgr. Dominik Pražák Pressure Department
More informationSonoSelect 10 and SonoSafe 10 energy meters
SonoSelect 10 and SonoSafe 10 energy meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationJOS 15 JOS 25 JOS 40. Manual and semiautomatic test benches from DN 25 to DN 40. Characteristics. Basic characteristics. Test bench using balances
TEST BENCHES JOS 15 JOS 25 JOS 40 Manual and semiautomatic test benches from DN 25 to DN 40 02 Characteristics Compact test benches - all in one room Designation - for residential and apartment meters
More informationSonoMeter 30 Energy Meters
Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationUNDERSTANDING, ACCELERATED
UNDERSTANDING, ACCELERATED MEASURE FLOW, PRESSURE, AND TEMPERATURE ALL IN ONE INSTRUMENT! Designed for Performance TSI thermal mass flowmeters incorporate a proprietary platinum film sensor design for
More informationIDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05
IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger
More informationGMC-I Service GmbH Calibration Center
2016 GMC-I Service GmbH Calibration Center DAkkS, ISO & Factorycalibration www.gmci-service.com From spare parts, reparation, rental service, maintenance of industrial health and safety standards, calibration
More informationOrganisation Internationale de Métrologie Légale
Organisation Internationale de Métrologie Légale OIML INTERNATIONAL RECOMMENDATION Pressure balances Manomètres à piston OIML R 110 Edition 1994 (E) CONTENTS Foreword... 3 1 Scope... 4 2 Terminology...
More informationFPG8601 Force Balanced Piston Gauge
FPG8601 Force Balanced Piston Gauge Reference Level Calibration System for very low pressure Pressure range: 0 to 15 kpa gauge, absolute and absolute differential Standard resolution: 0.010 Pa, high resolution
More informationTRZ 03-K Volumeter. Proven Technology. Superior Performance. TRZ 03-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering.
TRZ 0-K Volumeter TRZ 0-K Volumeter is a Turbine Gas Flowmeter for Secondary Gas Metering. TRZ 0-K Turbine Gas Flowmeter continues the tradition of Honeywell s field-proven turbine meter technology, delivering
More informationUnited Kingdom of Great Britain and Northern Ireland
(UK/0126/0074) MI-005 United Kingdom of Great Britain and Northern Ireland Certificate of EC type-examination of a measuring instrument Number: UK/0126/0074 issued by the Secretary of State for Business,
More informationCALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE. (+34)
CALIBRATION SERVICES HUMIDITY DEW POINT AIR VELOCITY MASS FLOW TEMPERATURE CO 2 PRESSURE (+34) 968 162 005 www.sensovant.com comercial@sensovant.com www.epluse.com CALIBRATION AT THE HIGHEST LEVEL The
More informationVaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.
Asset #: 123 Calibration - Certificate No: 2083.01 Customer: Condition: Action Taken: Sample Inc. 123 Sample Rd. Sample, MA 01234 The instrument was operational upon receipt. The instrument was adjusted
More informationCTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration
CTAG:ebdaf8e87fbb5996aefb9 Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 6858 Instrument Description Manufacturer Model Serial Number Inventory Number CABLE ANALYZER FLUKE NETWORKS DTX-8
More informationUnited Kingdom of Great Britain and Northern Ireland
(UK/0126/0026) MI-005 United Kingdom of Great Britain and Northern Ireland Certificate of EC type-examination of a measuring instrument Number: UK/0126/0065 issued by the Secretary of State for Business,
More informationTESTING BENCHES for watermeters
TESTING BENCHES for watermeters +372 6 480 235 Haljas tee 25, 12012 TALLINN Fax +372 6 480 125 Testing benches are designed by Tepso Ltd. for using in calibration laboratories and also in watermeter production
More informationDM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationTechnical Information Conducal CLY421
TI00496C/07/EN/01.12 71142150 Products Solutions Services Technical Information Conducal CLY421 Conductivity calibration set for ultrapure water applications Factory calibrated measurement box Certified
More informationCTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration
CTAG:b997e6abfa98cebb6b Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 79 Instrument Description Manufacturer Model Serial Number Inventory Number CABLE ANALYZER FLUKE NETWORKS DTX-8
More informationHANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1
HANDBOOK Ed. 2017 DS-ED 01/2017 - ENG 1 CHAPTER 9 BURSTING DISC DEVICES IN SERIES 3070 SCOPE Use: protection against possible overpressure of the apparatuses listed below, with regard to the operating
More informationMETHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER
1250 METHOD 25A - DETERMINATION OF TOTAL GASEOUS ORGANIC CONCENTRATION USING A FLAME IONIZATION ANALYZER 1.0 Scope and Application. 1.1 Analytes. Analyte CAS No. Sensitivity Total Organic Compounds N/A
More informationSupersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.
Bulletin Category: GAS Bulletin: G-23 Page: 1 of 7 The copy of this document located on Measurement Canada s website is considered to be the controlled copy. Recognition of data from specialty gas suppliers
More informationHUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0
High Accuracy Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationCertified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS
Certified Reference Materials FOR REFRACTOMETERS AND POLARIMETERS Regular verification of laboratory instrumentation is of primary importance in a modern manufacturing facility, not only for reasons of
More informationali-q TM Gravimetric Verification Procedure
ali-q TM Gravimetric Verification Procedure Introduction This document describes the recommended procedure for verifying performance of the ali-q aliquoting pipet controller using the industry standard-
More informationDM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø
More informationNMISA NEW GAS FLOW CALIBRATION FACILITY. Deona Jonker 7 October 2013
NMISA NEW GAS FLOW CALIBRATION FACILITY Deona Jonker 7 October 2013 Introduction Flow the total volume of a fluid that flows past a fixed point in a given time Flow measurements used in industry as a means
More informationAutomatic Isokinetic Sampler. ST5 Evo
Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,
More informationPressure is our Business
Pressure is our Business Count on gauges and calibrators that perform Wherever you work Reduce Measurement Error Protect against diminished accuracy from environmental conditions, accidental damage, and
More informationBeamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments
Beamex Calibration White Paper info@beamex.com Weighing scale calibration - How to calibrate weighing instruments Weighing scale calibration - How to calibrate weighing instruments Weighing scales, weighing
More informationETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05
Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing
More informationGas flow calibrations performed at the National Metrology Institute of South Africa (NMISA)
Int. J. Metrol. Qual. Eng. 5, 303 (2014) c EDP Sciences 2014 DOI: 10.1051/ijmqe/2014012 Gas flow calibrations performed at the National Metrology Institute of South Africa (NMISA) D. Jonker and E.P. Tarnow
More informationLight Lab. Reliable Measurements through Regular Calibration. DAkkS
Light Lab Reliable Measurements through Regular Calibration QM DAkkS ARS 85 EYREIENCEG QM EXP Benefits of Calibration PERFECTION THROUGH CALIBRATION RIN EASU HT M OLOGY IG L IN ECHN T LEGAL CERTAINTY Avoidance
More informationKENYA ACCREDITATION SERVICE
KENAS-GUD-016 01 16/03/2013 16 / 04/2013 GUD Page 1 of 18 Approval and Authorisation Completion of the following signature blocks signifies the review and approval of this Document. Name Job Title / Role
More informationHUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationGeneral European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT
General European OMCL Network (GEON) QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (09) 64 R5 QUALIFICATION OF EQUIPMENT ANNEX 6: QUALIFICATION OF PISTON PIPETTES Full document title and reference Document type
More informationCALIBRATION CERTIFICATE # 500
CALIBRATION CERTIFICATE # 5 Calibration date : -- Certificate issued : --8 Company name Company address City, Province, Canada CLAS 9- Calibration of Mass flow meter Brooks SLA585S S/N : ABCD QUALITY PROGRAM
More informationNational Health Service Model engineering Specification
National Health Service Model engineering Specification D 08 Thermostatic mixing valves (Healthcare premises) Issue date: Issue 4 Page 2 Contents Page No 0. Introduction 4 1. Scope 4 2. Definitions 6 3.
More informationNMISA New Gas Flow Calibration Facility
NMISA New Gas Flow Calibration Facility Speaker / Author: D. Jonker Co-author: E.P. Tarnow National Metrology Institute of South Africa (NMISA) Private Bag X34, Lynnwood Ridge, Pretoria, 0040, South Africa
More informationEN ISO/IEC Technical Requirements
EN ISO/IEC 17025 - Technical Requirements Wolfgang Garche Environmental Protection Agency Department Air Quality Monitoring, Information, Assessment 1 What means accreditation in accordance to EN ISO/IEC
More informationCertification of AMS acc. EN 15267, Part 3 - Overview and First Experience -
Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience - Dr. Wolfgang Jockel, Martin Schneider, TÜV Rheinland Group, D-51105 Cologne / Germany 1. Introduction A new basis for the certification
More informationTowards ISO Koos van Helden, B.ASc. International Account Manager Eastern Hemisphere mailto:
Towards ISO 17089-1 Koos van Helden, B.ASc. International Account Manager Eastern Hemisphere mailto: koos.vanhelden@kpnmail.nl Who am I? My name: Koos van Helden International Account Manager Eastern Hemisphere
More informationPERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN
METRIC 17 May 2013 SUPERSEDING MIL-PRF-27201D 07 February 2007 PERFORMANCE SPECIFICATION PROPELLANT, HYDROGEN This specification is approved for use by all Departments and Agencies of the Department of
More informationISO 3724 INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using particulate contaminant
INTERNATIONAL STANDARD ISO 3724 Second edition 2007-08-15 Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using particulate contaminant Transmissions hydrauliques Éléments
More informationJUMO dtrans p30 Pressure Transmitter
609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure
More informationZHM ST Series. Technical Datasheet. Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids
www.kem-kueppers.com Technical Datasheet ZHM ST Series Gear Flow Meters for lubricating, non lubricating, abrasive and corrosive fluids Certified zertifiziert according gemäß to DIN DIN EN EN ISO ISO 9001
More informationOIML R 140 RECOMMENDATION. Edition 2007 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Measuring systems for gaseous fuel
INTERNATIONAL RECOMMENDATION OIML R 140 Edition 2007 (E) Measuring systems for gaseous fuel Systèmes de mesurage de gaz OIML R 140 Edition 2007 (E) ORGANISATION INTERNATIONALE DE MÉTROLOGIE LÉGALE INTERNATIONAL
More informationEC type-examination certificate UK/0126/0065 Revision 1
UK/0126/0065 MI-005 EC type-examination certificate UK/0126/0065 Revision 1 issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments
More informationCOMPAFLOW. Compressed Air. Volumetric flow. Gas. Mass flow. Steam. Net volumetric flow. Liquid
Volumetric flow Compressed Air Mass flow Gas Net volumetric flow Steam Liquid Universal compact orifice flow meter combines a compact orifice flow sensor and sotiphicated converter One-piece flow sensor,
More informationWhite Paper August , Rev AA
Section 1 Automatic Tank Gauging in Custody Transfer Applications Abstract Today Automatic Tank Gauges (ATG s) are commonly used world wide for custody transfer of petroleum products. International standards
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 8655-4 First edition 2002-09-15 Piston-operated volumetric apparatus Part 4: Dilutors Appareils volumétriques à piston Partie 4: Diluteurs Reference number ISO 8655-4:2002(E)
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More informationMetering Code Gas TSO, measurement by connected party Effective from to the present
Please note that although Gasunie Transport Services B.V. translated the Dutch network codes with utmost care, Gasunie Transport Services B.V. would like to point out that only the decisions of the Dutch
More informationLM LUMEN MAINTENANCE TEST REPORT
Version: B LM-80-08 LUMEN MAINTENANCE TEST REPORT Company :UNISTARS Corporation Ltd. Sample Name :VENUS 3535 Sample Received :May 29 2012 Sample Tested :Feb 14 2013 TESTING LABORATORY IS ACCREDITED BY:
More informationParticulate Emission Monitor Correlation. Camden Power Station Stack No RSL152
Particulate Emission Monitor Correlation Camden Power Station Stack No. 3 2011 P.O. Box 2459 Noordheuwel ext 4 Krugersdorp 1756 Vat No. 4670254459 STACKLABS ENVIRONMENTAL SERVICES 10 Chisel Street Boltonia
More informationTranslation Principles of testing and certification for insulating hose assemblies on cable cutting devices
Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices Status as of 2014-01 Principles of testing Insulating hose assemblies on cable cutting devices
More informationTechnical Data Sheet. OPTIMASS 7000 Custody Transfer Mass Flowmeter
Technical Data Sheet KROHNE 12/2004 7.02516.21.00 CH/GR OPTIMASS 7000 Custody Transfer Mass Flowmeter with single straight measuring tube OIML R117 Pattern Approval Accuracy classes 0.3 / 0.5 / 1.0 / 1.5
More informationHUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationSTAINLESS STEEL OVERFLOW VALVE TYPE 417
MAIN CHARACTERISTICS The 417 valve is intended for the discharge of fluids overflow when an upstream limitation of pressure is looked for, for example downstream to a pump. This valve also works in presence
More informationShips tank - General requirements
INTERNATIONAL OIML R 95 RECOMMENDATION Edition 1990 (E) Ships tank - General requirements Bateaux-citernes - Prescriptions générales OIML R 95 Edition 1990 (E) ORGANISATION INTERNATIONALE DE MÉTROLOGIE
More informationSpecification For Water Meters. Pr10068
Specification For Water Meters Pr10068 Documents Details This document is only valid on the day it was printed. Version Review Revision Date issued Reviewed by Approved by Date approved Revision type 0.1
More informationImproved Reliability in Natural Gas Energy Measurement with the Revised ISO Standard. Gerard Nieuwenkamp - VSL
Improved Reliability in Natural Gas Energy Measurement with the Revised ISO 10723 Standard Gerard Nieuwenkamp - VSL Improved reliability in natural gas energy measurement with the revised ISO 10723 standard
More informationTechnical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media
www.kem-kueppers.com Technical Datasheet ZHA Series Gear Flow Meters Aluminum Version with ball bearing for lubricating media Certified zertifiziert according gemäß to DIN DIN EN EN ISO ISO 9001 9001 2
More informationGeneral Accreditation Guidance. User checks and maintenance of laboratory balances
General Accreditation Guidance User checks and maintenance of laboratory balances January 2018 Copyright National Association of Testing Authorities, Australia 2010 All intellectual property rights in
More informationTechnical Procedure for General Laboratory Equipment
Technical Procedure for General Laboratory Equipment 1.0 Purpose - This procedure specifies the required elements for the use of general laboratory equipment. 2.0 Scope - This procedure applies to all
More informationDesign Features. General Description
Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design
More informationISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid
INTERNATIONAL STANDARD ISO 23181 First edition 2007-08-15 Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid Transmissions hydrauliques Éléments
More informationINFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION.
Andrzej Hantz RADWAG BALANCES AND SCALES INFLUENCE OF MEASURING PROCESS AUTOMATION ON UNCERTAINTY OF MASS STANDARD AND WEIGHTS CALIBRATION. The article presents the influence of comparison process automatization
More informationPressure Metrology in Mexico
Pressure Metrology in Mexico Jorge C. TORRES G., Benjamin SORIANO C. and Victor ARANDA C. Centro Nacional de Metrologia-CENAM km 4,5 Carretera a Los Cues, El Marques, Queretaro, MEXICO e-mail: jorge.torres@cenam.mx
More informationA Rationale for Pressure Relief Device(s) Qualification Requirements (LH2)
UN-GTR PART A INSERTION Stand 09.02.2011, 17:20 Uhr A.3.3 HYDROGEN STORAGE SYSTEM The hydrogen storage system consists of all components that form the primary pressure boundary of the stored hydrogen in
More informationCalibration Summary of Test Report No.: Sample
Calibration Summary of Test Report No.:30043 Rion Type: NL52/EX Serial no: 00732122 Customer: Scantek, Inc. Address: 6430 Dobbin Rd., Suite C, Columbia MD, 21045 Contact Person: Mariana Buzduga Phone No.:
More informationMaterials : Stainless steel ASTM A351 CF8M
Certificat 3.1 Size: Ends : Min Temperature : Max Temperature : DN 15 to DN 200 PN16 Flanges R.F. - 20 C + 200 C Max Pressure : 16 Bars Specifiations : Removable stainless steel filter Bolted bonnet with
More informationRoad and rail tankers with level gauging Part 2 Metrological controls and tests. Page 1 of 42 OIML TC8/SC1/WG3/R 80-2 CD1 Draft of July
Page 1 of 42 OIML TC8/SC1/WG3 Circulated to Members of OIML TC8/SC1/WG3 Title Revision R 80-2 Road and rail tankers with level gauging. Metrological controls and tests Discussion by e-mail and at the meeting
More informationRotary valves HRB 3, HRB 4
Data sheet Rotary valves HRB 3, HRB 4 Description HRB rotary valves can be used in combination with electric actuators AMB 162 and AMB 182. Features: Lowest leakage in class Unique position indicator (visible
More information7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel
KROHNE 04/2003 7.02445.71.00 GR 7000 Series OPTIMASS Mass Flowmeters with single straight measuring tube Titanium Hastelloy Stainless Steel One tube no limits No limits with tube material No limits with
More informationElectronic Volume Correctors
Electronic Volume Correctors Ben Manson Landis+Gyr October 14, 2016 PUBLIC Agenda Customer Types and suitable equipment Volume corrector standards / regulations Basics of volume correction Gauge v Absolute
More informationBS12N Piezoresistive OEM Pressure Sensor
BS12N Piezoresistive OEM Pressure Sensor Model: BS12N-1 Model: BS12N-2 Feature Pressure range (-0.1~60)Mpa; Pressure reference: Gauge, absolute and sealed gauge; Constant current power supply; Isolated
More informationModel 601CV. Mass Flow Controller. Product Features:
Model 601CV Mass Flow Controller Porter s Model 601CV Series II Mass Flow Controller (MFCs) is designed for precise control of virtually all conventional process gases. The MFC consists of a thermal mass
More informationDifferential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting
Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in
More informationGFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features
Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma
More informationBursting strength of paper. 1. Scope
T 403 om-97 OFFICIAL STANDARD 1926 TENTATIVE STANDARD 1952 OFFICIAL STANDARD 1974 CORRECTED 1976 OFFICIAL TEST METHOD 1985 CORRECTED 1985 REVISED 1991 REVISED 1997 1997 TAPPI The information and data contained
More informationContinuous Gas Analysis In situ laser gas analyzers TÜV and MCERTS add-on for LDS 6 operating instructions Compact Operating Instructions
Continuous Gas Analysis In situ laser gas analyzers Compact Operating Instructions 1 LDS 6 TÜV/MCERTS certified analyzers for NH3/H2O, NH3 and H2O 1.1 Operation requirements Please observe the following:
More informationOIML R 126 RECOMMENDATION. Edition 1998 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION. Evidential breath analyzers DE MÉTROLOGIE LÉGALE
INTERNATIONAL RECOMMENDATION OIML R 126 Edition 1998 (E) Evidential breath analyzers Éthylomètres OIML R 126 Edition 1998 (E) ORGANISATION INTERNATIONALE DE MÉTROLOGIE LÉGALE INTERNATIONAL ORGANIZATION
More informationApplication Note AN-107
SPEC Sensor TM Characterization & Calibration Considerations Scope This document is provided to describe the considerations needed to characterize, calibrate, verify and validate the measurement performance
More informationChapter Pipette service & maintenance. Pipette specifications according to ISO Repair in the lab or return for service?
Pipette specifications according to ISO 8655 Chapter 5 5.1 The ISO 8655 standard gives the accuracy and precision limits as both absolute and relative values. Specifications will depend on the technique
More informationTechnote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits.
Page 1 of 15 - Dynamic Pressure and Regulation Valve Application system can be installed in domestic and commercial heating and cooling systems. system is a dynamic valve arrangement designed to regulate
More informationSeated valve for steam (PN 25) VFS 2 2-way valve, flange
Data sheet Seated valve for steam (PN 25) VFS 2 2-way valve, flange Description VFS 2 valve is a range of 2 port flanged valve for chilled water, PHW, MPHW, HPHW (low, medium or high pressure hot water)
More informationStandard Operating Procedure Measuring & Testing Equipment
Standard Operating Procedure Measuring & Testing Equipment Purpose: 7.6 Responsibility: 7.6d Scope To have a procedure to ensure that all is controlled, maintained and calibrated to ensure that Product
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 CAPSTONE CALIBRATION 7016 Baker Blvd Richland Hills, TX 76118 Jon T. Cappa Phone: 817 284 2707 CALIBRATION Valid To: January 31, 2020
More informationInformal document regarding progress of CEN standards for reference in RID/ADR
Joint Meeting of the RID Safety Committee and the Working Party on the Transport of Dangerous Goods (Berne, 13-24 March 2000) Informal document regarding progress of CEN standards for reference in RID/ADR
More informationRequirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T ( G)
Institut fédéral de métrologie METAS METAS-N001/EN Requirements for the certification of movements and mechanical watches resistant to magnetic fields of 1.5 T (15 000 G) This document is a translation
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. PRECISION MEASURING CORP Groesbeck Hwy. Fraser, MI Robert Meyer Phone:
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 PRECISION MEASURING CORP. 33250 Groesbeck Hwy. Fraser, MI 48026 Robert Meyer Phone: 586 293 4420 CALIBRATION Valid To: September 30, 2019 Certificate Number:
More informationMultifunctional Thermostatic Circulation Valve MTCV - Lead free brass
Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass Introduction Fig. 1 Basic version - A Fig. * Self-acting version with automatic disinfection function - B * thermometer is an accessory
More informationDigital pressure gauge Model CPG500
Digital pressure gauge Model CPG500 WIKA data sheet CT 09.01 for further approvals see page 3 Applications Calibration service companies and service industry Measurement and control laboratories Quality
More informationVortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas
Vortex Flow Meter Wafer or Flange Connection - Steam - Liquid - Gas Working Principle & Circuit Diagram Working Principle When a column body placed in flowing fluids in pipe, a series of vortices will
More information