CFH Series High Efficiency Filters

Size: px
Start display at page:

Download "CFH Series High Efficiency Filters"

Transcription

1 FH Series High fficiency Filters Intelligent ir Technology

2 Save energy, dollars & protect your air system The ompressed ir hallenge, a government/ industry sponsored energy savings awareness program, estimates that $1.5 billion dollars a year is spent in the US to compress air. Over 20% of this could be saved by better design and management of compressed air systems. xcessive filter pressure drop is a key target to achieve this goal. Your compressed air is contaminated! irborne water vapor and dust are drawn into your compressor intake. The compressor adds oil aerosols, vapors and wear metals. Piping can add rust and scale. ompir FH Industrial High fficiency Filters can save energy dollars because they have a lower pressure drop throughout the Filter lement life, when compared to competitive filters using older wrapped / pleated element technology. on t be fooled by calculated savings from competitive de-mister filter modules. They do not have the efficiency of the ompir lement, so tiny particulates flow downstream to pneumatic equipment, causing the wear and damage that a filter should prevent. ontaminated ir Multi-Wrap Media & Fibreglass Support / Prefiltration Reticulated Foam rainage layer lean ir 10 Typical Pressure rop urves for 0.01 micron ompressed ir Filters 9 8 Wrapped or Pleated lements with ated technology Real ollars xample: With a 200 HP ir ompressor running 24 hours per day, at 93% motor efficiency, and an electrical cost of $0.10/kW-HR, the 3 psid lower average pressure drop of a ompir filter would represent an annual saving of over $3,000! system that has three filters can save up to $9,000 per year. verage Pressure rop (psid) nergy ost Savings FH ompir Technology with 3 psid lower average pressure drop over element life 0 New lement lement Life Recommended lement hange

3 Introducing ompir s High Technology Filter lements Unique Push-Fit, ouble O-Ring Seal Filter-to-head chamfered connection for ease of installation and removal. liminates tie rods. Steel Support Fiberglass Support Provides prefiltration. eep ed Multi-Wrap orosilicate Glass Microfiber Large flow passages prevent high pressure drop and allow for a high dirt holding capacity. Wrap tension prevents channeled air flow. Suitable for temperatures up to 140 F. Low average pressure drop over life of element. Regular replacement suggested for best performance and energy cost savings. Fiberglass Support Provides prefiltration. Steel Support Foam Sock - anti re-entrainment barrier for collected liquid drainage prevents carryover. nd ap is a durable and non-corrosive glass filled nylon which is attached to the element with a multi part urethane resin. The element is then held in place by internal ribs within the filter housing. Low Operating ost RGULR FILTR LMNT RPLMNT SVS MONY. IT MINIMIZS PRSSUR ROP N NSURS PROTTION OF YOUR OMPRSS IR SYSTM, PNUMTI QUIPMNT, N FINISH PROUT.

4 21st century filtration Pop-up Indicator RQUIR LRN FOR LMNT RMOVL ON OMPTITIV FILTR PROUTS Only 4-7" clearance for element removal Modular NPT onnections Option to bolt multiple filters together with Hi-Nitrile O-ring connection for ease of installation, eliminate leaks and space saving. Heavy luminum onstruction astings 100% leak-tested, 300 psi pressure and 250 F temperature ratings. nnular Seal and aptive O-Ring between head and bowl with threaded connection to prevent leaks. xternal Ribs for easy bowl removal. Internal Ribs secure element in-place and form dead-air zone to prevent condensate re-entrainment. Large apacity ondensate sump with automatic drain valve is standard so coalesced condensate is always removed. Hexagon on bottom for easy bowl removal. Threaded ottom Port external auto or manual drain.

5 Features & enefits Performance Monitoring asy indication of excessive pressure drop to reduce energy costs. Pop-up P Indicators Standard on FH0015 and FH0030, optional on other models Nylon pop-up is compatible with synthetic oils and lubricants. elta-p Gauge Standard on FH0065 thru FH16100 P gauge face is not pressurized. Unique magnetic sensor survives high impact. P gauge can be remote or panel mounted. Remote ontact P larm (Optional) ry contacts close at 6 psid to send a notification signal to a bell, light, or control panel. an be field installed. Modular Head esign ( scfm) Multiple filters can be bolted together with O-ring seal. Minimizes threaded connections leak points. Simplifies installation. Saves space. Modular mounting kits available with high tensile strength cap screws with nuts and O-ring. ccessories K - onnecting Kits vailable for models SFM. Side Port ( scfm) Side mounting of external auto drain for low clearance applications. an be used as a separate manual drain or as a vent line connection to an external demand drain mounted to bottom connection. ottom rain dapter Plate ( scfm) Releases drain adapter for ease of float drain maintenance. asy disconnect of external drain when element is changed.

6 Typical ompressed ir Treatment System ISO : 2001() System Ratings Filter Grade Selection ISO System Quality lass pplications Rating i ir Tools, ir Motors ii utomated quipment, Robotics, Rough Paintings iii Injection Molding, lectronics iv or Semi-onductors, Instrumentation v or Food Processing, Hospital Grade, reathing ir WRNING: ompir reathable ir systems are designed to offer the user protection in potentially harmful environments, as such it is imperative that these products are correctly installed and properly controlled by a competent person. Proper control means the equipment installed should be fully checked prior to every use, should any fault be discovered it must be repaired or the failed component replaced to guarantee full working order before use. ompir reathable ir systems are not designed to remove O, O 2,NO x and SO 2. If in doubt do not use the system until it has been confirmed to be fit for purpose by the ompir technical department. I. II. Intake Filter III. ir ompressor fter ooler Wet Receiver To II, III, IV or V Recommended ryer / Filter ypass (Typical) ypass ypass WS Refrigerated ryer Refrigerated ryer General Purpose, oalescing and ulk ontaminant Removal; point- of-use. Prefiltration to refrigerated dryer; higher efficiency, coalescing point-of-use. High efficiency coalescing oil removal after refrigerated dryer; upstream of desiccant dryers. Oil vapors / odor / taste removal downstream of filter. IV. Heatless esiccant ryer ypass Reverse Flow P fterfilter to heatless desiccant dryer. V. Heatless esiccant ryer 3 ISO : 2001() Quality lass Solid ntmnts Max. Pressure Max. Oil ontent Quality (max. particle ew Point (droplets, aerosols lass size in microns) F & vapor) ppm not specified sk ompir about applying condensate management systems, dry air storage and flow controllers. Specifications General Purpose Prefiltration/ High ctivated?? Point-of-Use oalescing fficiency harcoal Particle removal micron Maximum carryover at 68 F ppm N/ Maximum recommended temperature F Pressure drop - clean and dry psid Pressure drop - oil saturated psid N/ N/ Pressure drop - change element psid N/ 5.8 lement media borosilicate microfiber multi-wrap carbon impregnated paper comb. &V Housing material high quality aluminum/sm high carbon steel Maximum working pressure psig Note: ctivated charcoal filters must not operate in oil saturated conditions and will not remove certain types of gases including carbon monoxide and carbon dioxide. hange interval depends on application, please contact ompir. lso see WRNING NOT above for reathable ir systems. orrection Factors For maximum flow rate, multiply model flow rate shown in the top chart by the correction factor corresponding to the working pressure. See specifications for maximum pressure. Operating Pressure (psig) orrection Factor Note: To reduce pressure drop by 50%, reduce flow rate by 30%.

7 imensions 3.0" 1.6" Model FH0015 thru FH0030 Models FH0065 thru FH650 (Pop-up option shown) Models FH1000 thru FH1500 Models F700* thru F16100* ual certified SM and RN coded vessels are standard. Model Flow Rate imensions inches NPT onnections Weight Replacement Number SFM Nm 3 /h In/Out Side ottom** lbs lement Model FH0015* " 12.00" 4.00" 6.00" 7.00" 1/4" N/ 1/8" MPT 2.0 F0015 [ * ] SM & RN ode Vessels luminum Housings FH0030* " 7.50" 4.00" 1.50" N/ 3/8" N/ 1/8" MPT 1.5 F0030 [ * ] FH0065* " 10.50" 6.00" 1.50" 1.25" 1/2" 1/4" 1/8" MPT 4.5 F0065 [ * ] FH0085* " 10.50" 6.00" 1.50" 1.25" 3/4" 1/4" 1/8" MPT 4.5 F0075 [ * ] FH0125* " 14.00" 6.00" 1.50" 1.25" 1" 1/4" 1/8" MPT 5.5 F0100 [ * ] FH0175* " 14.00" 6.00" 1.50" 1.25" 1" 1/4" 1/8" MPT 5.5 F0150 [ * ] FH0250* " 19.00" 6.50" 2.00" 1.50" 1 1/2" 1/2" 1/4" 12.0 F0225 [ * ] FH0325* " 19.00" 6.50" 2.00" 1.50" 1 1/2" 1/2" 1/4" 12.0 F0300 [ * ] FH0450* " 19.00" 6.50" 2.00" 1.50" 2" 1/2" 1/4" 12.0 F0450 [ * ] FH0650* " 26.75" 6.50" 2.00" 1.50" 2" 1/2" 1/4" 12.5 F0650 [ * ] FH1000* " 27.50" 7.00" 2.50" 1.50" 3" 1/2" 1/2" 32.0 F1000 [ * ] FH1250* " 32.50" 7.00" 2.50" 1.50" 3" 1/2" 1/2" 33.5 F1250 [ * ] FH1500* " 38.50" 7.00" 2.50" 1.50" 3" 1/2" 1/2" 35.5 F1500 [ * ] F2100* " 10.80" 32.00" 48.20" 38.40" 4" flg 1/2" 1/2" 326 F700 [ * ] (3 ea.) F2800* " 12.80" 32.00" 50.30" 39.30" 6" flg 1/2" 1/2" 439 F700 [ * ] (4 ea.) F3500* " 12.80" 32.00" 50.30" 39.30" 6" flg 1/2" 1/2" 439 F700 [ * ] (5 ea.) F4200* " 14.00" 32.00" 54.30" 40.40" 6" flg 1/2" 1" 536 F700 [ * ] (6 ea.) F5600* " 16.00" 32.00" 55.10" 40.60" 8" flg 1/2" 1" 647 F700 [ * ] (8 ea.) F7000* " 18.00" 32.00" 58.10" 42.60" 8" flg 1/2" 1" 778 F700 [ * ] (10 ea.) F8400* " 18.00" 32.00" 58.10" 42.60" 10" flg 1/2" 1" 778 F700 [ * ] (12 ea.) F9800* " 20.00" 32.00" 59.40" 42.80" 10" flg 1/2" 1" 936 F700 [ * ] (14 ea.) F11200* " 24.00" 32.00" 61.00" 43.20" 10" flg 1/2" 1" 1214 F700 [ * ] (16 ea.) F12600* " 24.00" 32.00" 61.00" 43.20" 10" flg 1/2" 1" 1214 F700 [ * ] (18 ea.) F16100* F F 32.00" F F 12" flg 1/2" 1" F F700 [ * ] (23 ea.) * Fill in element grade ( ) to appropriate model number. ** ottom drain, 1/8" MPT with mechanical float drain. Ordering Information FH / / / luminum Housings SM & RN ode Vessels lement Grade Options * 0065* 0075* * * * * G - 5 micron bulk liquid / particulate P - 1 micron coalescing / particulate micron coalescing V - ctivated charcoal / vapor removal RP - Reverse flow P afterfilter P - Pop-up Indicator (available on SFM models, only on G, P,, and RP grades) R - ifferential pressure gauge with remote alarm (available on SFM G, P,, RP grades)

8 Intelligent ir Technology ompressed air solutions for every application OMPRSSORS cfm 1-350HP LURIT Rotary Vane Single Stage Screw Speed Regulated Screw Piston Portable OMPLT SSORIS PROGRM Filters and ryers ooling Systems Heat Recovery ondensate Management ir Receivers Multi-Set ontrollers Lubricants VLU SRVIS ir udit Performance Reporting Utility ir Performance ontracting OMPLT SRVI FOR OMPRSS IR THNOLOGY ngineering of omplete ompressor Stations Local Service enters Guaranteed Parts vailability OIL-FR Two Stage Screw Water-Sealed Screw Piston Portable ompir anada Inc 871 ranberry ourt Oakville, Ontario L6L 6JY anada ompir anada Inc 4875 Rue ourg Ville St. Laurent, Montreal, Quebec H4T 1H9 anada Tel: Fax: Tel: Fax: compair@compair.ca web: compair@compair.ca web: ompir is an ISO 9001 registered company ompir policy is one of continuous improvement and we therefore reserve the right to alter specifications and prices without prior notice. ll products are sold subject to the ompany s conditions of sale. rochure re-order ref: -101F

SULLAIR SX Filtration Series ,000 scfm

SULLAIR SX Filtration Series ,000 scfm SULLAIR SX Filtration Series 25 21,000 scfm The Importance of Reliable Filtration Contaminants are introduced at various stages of the air compression cycle. Removing these contaminants is vital to help

More information

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators Page 1 of 6 TI-P510-01 H Issue 5 IP2, IP2 and IP2D ISO 9001 Spirax-Monnier International ompressed ir Filter/ Regulators ert. No. LRQ 0963008 Description The IP range of Spirax-Monnier international compressed

More information

exceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr)

exceeds global breathing air quality standards B 1 breathing air systems flow capacity: scfm flow capacity: scfm ( Nm 3 /hr) exceeds global breathing air quality standards B 1 breathing air systems flow capacity: 6-486 scfm flow capacity: 8-1500 scfm (13-2550 Nm 3 /hr) breathing air systems flow capacity: 6-486 scfm B 1 Leading

More information

B-Series. breathing air systems flow capacity: scfm

B-Series. breathing air systems flow capacity: scfm B-Series breathing air systems flow capacity: 14-486 scfm B 1 B-Series breathing air systems flow capacity: 14-486 scfm B 1 Leading edge technology and more than 100 years of experience nano-purification

More information

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2/05 GENERAL

More information

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL 1 SERVICE MANUAL MODEL BA200AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2 GENERAL

More information

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators L ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification

More information

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA200AA-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 1/00 2 GENERAL

More information

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6

List of Contents vma. Compressed Air Conditioning 2. System description 2. Individual Units Pre-Filters 3. Combinations 6 Úprava stlačeného vzduchu EWO VMA List of Contents System description Individual Units Pre-Filters 3 Micro-Filters 4 Activated-Charcoal-Filters 5 Combinations 6 Accessories and Main spare parts 6 Service

More information

Guardian Membrane Separators

Guardian Membrane Separators Guardian Membrane Separators Our Guardian Membrane Separators and Spin Clean filters offer superb protection with easy field maintenance. The Guardian Membranes are ideal for protecting GC s, O 2 Analyzers,

More information

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL www.modsafe.com SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device.

More information

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100 Clean Air Filter Variations SFD SFD SFD SFD Made to Order Type Disposable (non-replaceable element) Cartridge (replaceable element) Flow rate L/min (ANR) (at inlet pressure.7 MPa) Up to 6 Up to 8 Up to

More information

Compressed Air Cleaning Filter Series

Compressed Air Cleaning Filter Series Compressed ir Cleaning Filter Series M /FF Series For Water Droplet, Solid/Oil Separation and Deodorization Modular connection, Space-saving design, Labor-saving in piping! Uses the same spacer as the

More information

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6 List of Contents VMA System description Individual Units Pre-Filters 3 Micro-Filters Activated-Charcoal-Filters 5 Combinations Accessories and Main spare parts Service Units G 1 / Pre-Filter Micro-Filter

More information

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL Product Manual MST Portable Air Filtration System SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the

More information

Related Products: Auto Drain Valve. Model/Specifications. Model

Related Products: Auto Drain Valve. Model/Specifications. Model Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

www.ompressedairsystems.com ultra-high purity nitrogen generators nitrogen purity: 95% to 99.999% www.ompressedairsystems.com ultra-high purity nitrogen generators nitrogen purity: 95% to 99.999% Leading

More information

MAINTENANCE AND OPERATING MANUAL

MAINTENANCE AND OPERATING MANUAL MAINTENANCE AND OPERATING MANUAL Cyclone condensate separator Type ASA EN EN Maintenance and operating manual Purpose and appropriate use Dear Customer, thank you for choosing our product. In order to

More information

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL

SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL SERVICE MANUAL MODEL BA020AMST BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 5/08 2 GENERAL

More information

AIRLINE-SERIES HELMET AIR FILTER

AIRLINE-SERIES HELMET AIR FILTER OWNER S MANUAL AIRLINE-SERIES HELMET AIR FILTER IMPORTANT WARNING FOR SAFER BLAST CLEANING 1. Use protective equipment: Abrasive-resistant clothing, safety shoes, leather gloves, ear protection, CE-approved

More information

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of. 3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems Work in a World of Comfort 3M TM Versaflo TM AP-600 Series Air Filtration Panels (AFP)

More information

3/8" Dr. Air Butterfly Impact Wrench

3/8 Dr. Air Butterfly Impact Wrench 8192106 3/8" Dr. Air Butterfly Impact Wrench Owner s Manual Read and understand all instructions before use. Retain this manual for future reference. Specifications Construction: Polished aluminum and

More information

Breathable Compressed Air

Breathable Compressed Air aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Breathable Compressed Air Typical Hazardous Substances Biological agents

More information

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology V-Major, V-Compact Reciprocating Compressors Intelligent Air Technology & Significant Energy Savings with Lower Running Costs Efficient. LOW POWER CONSUMPTION 75% of the running cost of an air compressor

More information

Filter / Regulator Numbering System

Filter / Regulator Numbering System atalog 9M-TK-19- Filter / Regulator Numbering System Filter / Regulator Numbering System Unit Thread Pipe Preset / Function Family Type Size Options Options Options Options Pressure Limited 2 Unit Function

More information

/ /

/ / GN 4- kw/5.5-0 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN: the dual output solution From cargo blanketing in LNG vessels to the inflation of Formula tires, nitrogen is used in

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Dehydration Assembly Model DA-1 Drawing No.: AD079CO, AD285CR Manual No.: IOM-018 The information in this manual has been carefully checked for accuracy

More information

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER MODEL F-4 DRAWING NUMBERS AD042C[ ] AD054C[ ] MANUAL NUMBER IOM-046 REVISION Rev. F, 4/23/2018 TABLE OF CONTENTS SAFETY 3 1. PRODUCT

More information

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0 ir line equipment P1H, PTH Filter/Regulator- Lubricator Combination Units 07 Series Compact design Filter removes liquids and solid particles down to 5 µm Push to lock adjusting knob with tamper resistant

More information

Compressed Air - Food/Bev. Presented By: Adam Zimmerman

Compressed Air - Food/Bev. Presented By: Adam Zimmerman Compressed Air - Food/Bev Presented By: Adam Zimmerman Meeting Summary Metro Air Treatment Compressor Types & Selection Measurment Questions Metropolitan Air Compressor Co., Inc. Serving the Michigan Market

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

CASH VALVE CRYOGENIC CONTROLS

CASH VALVE CRYOGENIC CONTROLS SH VLVE ryogenic control for pressure build regulators, pressure reducing valves, final line gas valves and combination pressure build economizer valves. Description ryogenics the science of materials

More information

OPERATION MANUAL NTF-15

OPERATION MANUAL NTF-15 OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

Avenger Model 33M Installation & Operation Instructions

Avenger Model 33M Installation & Operation Instructions Avenger Model 33M Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737 Phone:

More information

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward GN 4-7 kw/5.5-10 hp Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward Total capability, total responsibility Right at the heart of your business, Atlas Copco delivers quality compressed air

More information

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal

More information

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Low-Pressure Gas Compressors 1500 to 6000 PSI hydro-pac, inc. LX-SERIES Features Hydro-Pac LX-SERIES Gas Compressors feature: Oil-free non lubricated gas pistons and cylinders

More information

Atlas Copco Tools & Assembly Systems. Air Line Accessories Optimizers- FRL

Atlas Copco Tools & Assembly Systems. Air Line Accessories Optimizers- FRL Atlas Copco Tools & Assembly Systems Air Line Accessories Optimizers- FRL MIDI Optimizer FRL Why use an Atlas Copco FRL? Atlas Copco filters, regulators, and lubricators are designed to help you get maximum

More information

RegO Adapters, Connector, & Fittings

RegO Adapters, Connector, & Fittings RegO dapters, onnector, & Fittings Extended Type ouplings for Vapor and Liquid Service esigned especially for liquid filling and vapor equalization of LP-Gas and anhydrous ammonia. The limited travel of

More information

ACME Connectors and Fittings Extended Type Hose Couplings for Vapor and Liquid Service A7571 and A7575 Series

ACME Connectors and Fittings Extended Type Hose Couplings for Vapor and Liquid Service A7571 and A7575 Series M onnectors and Fittings xtended Type Hose ouplings for Vapor and Liquid Service 7571 and 7575 Series esigned especially for liquid filling and vapor equalization of LP-Gas and anhydrous ammonia. The limited

More information

Breathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards

Breathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards Breathing Air Purifiers Comply with OSHA Grade D, NFPA-99, European Pharmacopoeia and other International Breathing Air Standards www.domnickhunter.com domnick hunter Breathing Air Purifiers provide air

More information

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA020ANM-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 6/08 2 GENERAL

More information

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator Installation, Operation, and Maintenance Manual Parker Balston Figure 1 - N2-04 Nitrogen Generator These instructions must be thoroughly read and understood before installing and operating this product.

More information

Niltox Breathing Air Purifier Range

Niltox Breathing Air Purifier Range Breathing Air Requirements The main standards affecting breathing air are BSEN529, EN12021 and COSHH. The requirements for a breathing air system are shown in the table opposite and the requirements for

More information

Technical Information

Technical Information Technical Information Installation, Operation, Installation, Operation and Maintenance and Maintenance Manual Manual Balston Model 75700-K728 Nitrogen Generator Figure 1-75700-K728 Overall Dimensions These

More information

Constant Pressure Crude Oil Container Model CPCCP

Constant Pressure Crude Oil Container Model CPCCP Installation, Operations, and Maintenance Manual Constant Pressure Crude Oil Container Model CPCCP The information in this manual has been carefully checked for accuracy and is intended to be used as a

More information

OPERATION MANUAL NTF-60 Plus

OPERATION MANUAL NTF-60 Plus OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

Potter Nitrogen Generators

Potter Nitrogen Generators Potter Nitrogen Generators What is nitrogen? Nitrogen the inert gas Earth s atmosphere the air we breathe is composed of nitrogen, oxygen, and water vapor. While this atmosphere is great for life, it is

More information

MF2M Monnier Miniature Compressed Air Filter

MF2M Monnier Miniature Compressed Air Filter 5040050 / 2 IM-P504-02 CH Issue 2 MF2M Monnier Miniature Compressed Air Filter Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation and commissioning

More information

INSTRUCTION MANUAL & PARTS

INSTRUCTION MANUAL & PARTS AIR LINE PURIFIERS FOR BREATHING EQUIPMENT AP-C RADEX INSTRUCTION MANUAL & PARTS 01-0-11 introduction CANABLAST BREATHING EQUIPMENT PURIFIER CAN BE USED IN CONBINATION WITH WITH OTHER SAFEGUARDS TO SUPPLY

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa 0. MPa.0 MPa (Note

More information

Liquid Level Controls

Liquid Level Controls Series RS High Pressure Sensors & Probes For onductance ctuated ontrols Series RS Sensors Series-RS-X-BR-: NM 4X nclosure For sophisticated multi-level control in tanks, boilers and hydronic systems Remote

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

Right-Angle Tube Roller Model

Right-Angle Tube Roller Model SPECIFICATIONS Model no. Free Speed (RPM) Throttle Rotation Max. Torque Ft-Lb Air Pressure psi Air Inlet Hose Air Flow @Free Speed Spindle Weight 909-1700 95 Lever type Reversible 240 90 1/2 NPT 1/2 I.D.

More information

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9 uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa Max. operating pressure

More information

1200 Series Pressure Regulators

1200 Series Pressure Regulators SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of

More information

REFRIGERATION SYSTEM COMPONENTS

REFRIGERATION SYSTEM COMPONENTS REFRIGERATION SYSTEM COMPONENTS henrytech.com Conventional Oil Separators The function of an Oil Separator is to remove oil from the discharge gas and return it to the Compressor either directly or through

More information

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:

More information

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS

VG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal

More information

B84G - Excelon Plus Modular System General purpose filter/regulator

B84G - Excelon Plus Modular System General purpose filter/regulator > Port size: 3/8" to 3/4" (PTF/ISO G) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant

More information

High Pressure Bleed Valves, Gauge Valves and Block & Bleed Valves

High Pressure Bleed Valves, Gauge Valves and Block & Bleed Valves High Pressure leed Valves, Gauge Valves and lock & leed Valves FITOK Group FITOK GmbH (Headquarter) Sprendlinger Landstr., 9 Offenbach am Main, Germany Tel.: +9 9 9 9 Fax: +9 9 9 9 FITOK, Inc. North Promenade

More information

INTRODUCTION... 3 II II II II II II II II II II II II II I 4-5 ASSEMBLY... 6,7,8 II II II II II II II... 9

INTRODUCTION... 3 II II II II II II II II II II II II II I 4-5 ASSEMBLY... 6,7,8 II II II II II II II... 9 Instruction Manual rode~ AIRLINE F I LTER INTRODUCTION... 3 WARNINGS I 4-5 ASSEMBLY... 6,7,8 OPERATION I... 9 MAINTENANCE I Ill 1 0,11 PARTS LIST I 12 RPB 62/2 a rode~ A I R L I N E F I L T E R..: INTRODUCTION

More information

Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98

Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98 Vickers Filters Reservoir Vent Filters Spin-on Air Filters & Adaptors Rev. 3/98 73 Introduction Prevent Airborne Ingression A key element of contamination control is reservoir vent filtration. Reservoir

More information

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20 Nitrogen Generators PMNG Commercial Series Section 50 Bulletin A -20 2 All nitrogen generators Whatever the problem; Pneumatech has the solution. are not created equal. Some may cost less and appear great

More information

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions 0575050/2 IM-P057-04 CH Issue 2 IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions 1 Safety information 2 General product information 3 Installation and commissioning

More information

Advantage 4000 Abrasi-Blast Respirator

Advantage 4000 Abrasi-Blast Respirator Advantage 4000 Abrasi-Blast Respirator Features Constant Flow Air-Line Respirator and Constant Flow Duo-Flo Respirator options Choice of shoulder length or waist length hoods to meet various blasting applications

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this

More information

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment Page 1 In order to ensure that the Compressed Air Challenge Fundamentals of Compressed Air Systems Training is most useful to you, it will be important for you to bring information about your plant s compressed

More information

PRODUCT OPERATING MANUAL

PRODUCT OPERATING MANUAL PRODUCT OPERATING MANUAL PANBLAST TM VISIFLO RESPIRATOR AIRLINE FILTERS Manual Number: ZVP PC 0084 01 Pressure Equipment Directive 97/23/EC SECTION 1. GENERAL INFORMATION 2. INTRODUCTION 3. PREPARATION

More information

VEP-PSERIES INTERCHANGE > Stucchi VEP profile

VEP-PSERIES INTERCHANGE > Stucchi VEP profile VPPSRIS INRHAN > Stucchi VP profile HNIAL AURS AN OPIONS Interchange Stucchi VP profile Sealing description Nitrile NR onnection system Screw SUHI SOLUIONS Available sizes Material /treatment Available

More information

Float Operated Level Controllers

Float Operated Level Controllers CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions

More information

Model Series 62 Constant Differential Relay

Model Series 62 Constant Differential Relay Siemens Industry, Inc. INSTALLATION AND SERVICE INSTRUCTION INTRODUCTION Model Series 62 Constant Differential Relay Rev 11 March 2011 Supersedes Rev 10 The Constant Differential Relay maintains a constant

More information

Excess Flow Valves. General Information. How They Work. An Explanation and Warning. Proper Installation

Excess Flow Valves. General Information. How They Work. An Explanation and Warning. Proper Installation xcess low Valves General Information RegO xcess low Valves have been designed, developed, and manufactured for a wide variety of industry needs for more than three decades. Throughout the years, those

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013 September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50 Systems Outfitted with ABM-725 Monitor C O M P A N Y INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50 Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y OFFICE: (507) 843-4700 P.O. BOX 7079 Toll

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

The Enerpac Lightweight Aluminum Cylinders

The Enerpac Lightweight Aluminum Cylinders The nerpac Lightweight luminum s Shown: RC, RCL, RC, and RR R : 20-150 tons - inches Lightweight, easy to carry and position to allow a higher cylinder capacity-to-weight-ratio Non-corrosive by design,

More information

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator Type 478 Pressure Regulator Application pressure regulator used to provide pneumatic measuring and control equipment with a constant air supply Set point ranges. to.6 bar ( to 4 psi) or. to 6 bar (8 to

More information

Compressed Airline Breathing Apparatus

Compressed Airline Breathing Apparatus Compressed Airline Breathing Apparatus [ The Independence in Breathing] The Complete Range at a Glance Full face mask with lung governed demand valve Light duty airline breathing apparatus Cavair LDA Pressure

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301 THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION Installation, Operation, and Maintenance Balston Model 75-77 Nitrogen Generator Figure 1-75-77 Overall Dimensions These instructions must be thoroughly read and understood before

More information

Pressure Sensing Valve - Model 4023

Pressure Sensing Valve - Model 4023 Pressure Sensing Valve - Model 4023 Overview AMOT Model 4023 can be used as a 2 or 3-way capacity, pressure sensing valve. This valve is ideal for applications that require compressor suction and discharge

More information

SRL SEries. Oil Free Scroll Air Compressors hp kw

SRL SEries. Oil Free Scroll Air Compressors hp kw SRL SEries Oil Free Scroll Air Compressors 2 44 hp 1.5 33 kw Sullair and Hitachi When Sullair became A Hitachi Group Company in July, 2017 two compressor titans joined forces bringing customers more solutions

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

Installation and User Manual

Installation and User Manual 49124589 Revision A August 2015 PacE Flow Controller Installation and User Manual Save These Instructions Table of contents Table of contents..................................................... 2 INSTALLATION............................................................3

More information

Compressed Air Filtration

Compressed Air Filtration ilter for high pressure MAIN EATURES & ENEITS: Innovative iltration technology, high retention rate, low pressure loss ilter housing made of aluminium resp. steel, designed for operating pressure up to

More information

FILTER REGULATOR. We produce with artistic attitude.

FILTER REGULATOR. We produce with artistic attitude. FILTER REGULTOR We produce with artistic attitude. DURY from Germany is expert in fluid control; the products are mainly for control and measurement of various gases, liquid pressure and flow, including

More information

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work? 94270 What is Tank Blanketing? blanketing systems are used to prevent the escape of liquid vapors into the atmosphere or to prevent moisture from entering a tank and contaminating its contents. A tank

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

ADVANCED AIRLINE FILTER INSTRUCTION MANUAL

ADVANCED AIRLINE FILTER INSTRUCTION MANUAL ADVANCED AIRLINE FILTER INSTRUCTION MANUAL CONTENTS Read all instructions and warnings before using this product. Keep this manual for future reference. INTRODUCTION 3!WARNINGS! 5 BASEMOUNT ASSEMBLY 6

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position.

Instructions. Control Solution ICF 20-4, ICF 25-4, ICF ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position. 027R9782 Instructions Control Solution ICF 20-4, ICF 25-4, ICF 32-4. ICF 40-4, ICF 20-6, ICF 25-6, ICF 32-6, ICF 40-6, Direction and position ICF xx-4 ICF xx-6 ICF xx-4 / ICF xx-6 with ICM ICM 027R9782

More information

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)

THE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...

More information