1 Proportional Two-Stage Directional Valves Servo Performance with Double Spool Feedback KHDG5V-5/7/8/1 12 Design Pressures to 35 bar (5 psi)

2 Contents INTRODUCTION General description....3 Features and benefits....3 Typical section....3 MODEL CODE 4 SPOOL DT 6 FUNCTIONL SYMOL 6 OPERTING DT 8 PRESSURES ND MINIMUM FLOW RTES 9 PERFORMNCE CURVES 1 Power capacity envelope....1 Pressure gain....1 Frequency response...1 Flow gain DIMENSION KHDG5V-5/7/8/1 14 MOUNTING SURFCE INTERFCE KHDG5V-5/7/8/1 16 ELECTRICL INFORMTION 18 lock diagram...18 Typical connection arrangements...18 PPLICTION DT 22 Fluid cleanliness...22 Hydraulic fluids...22 Installation Service information This product has been designed and tested to meet specific standards outlined in the European Electromagnetic Compatibility Directive (EMC) 214/3/EU which repealed Directive 89/336/EEC, amended by Directives 91/263/EEC, 92/31/EEC, 93/68/EEC and 93/97/EEC. For instructions on installation requirements to achieve effective protection levels, see the leaflet and Installation Wiring Practices for Eaton s Electronic Products leaflet Wiring practices relevant to this Directive are indicated by Electromagnetic Compatibility (EMC). 2 KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September 217

3 Introduction General description Eaton proportional valves shown in this catalog are suitable for working pressures up to 35 bar (5 psi) and flow rates to 72 l/min (19 USgpm). They are designed to provide a controlled oil flow in proportion to a command signal, with spool position feedback to provide accurate control. Zero lapped spools are available for closed loop control applications and hydrostats are available for load compensation. KHDG5V-5/7/8/1 range of proportional directional valves with control amplifiers built directly on, and prewired to the valves. Factory-set adjustments of gain, spool deadband compensation, and offset ensure high valve-to-valve reproducibility. The only electrical inputs required are power supply (24V) and a voltage command signal of ±1V. The amplifier is housed in a robust metal enclosure, sealed against ingress of water and other fluids. Electrical connections are via a standard 7-pin plug. spool position monitor point allows the function of the valve to be electrically monitored. Ramp functions, if required, can be generated externally. Features and benefits Factory-sealed adjustments increase valve-to valve reproducibility. Valve with integrated amplifier selected, ordered, delivered and installed as one performance tested package. Electronic feedback LVDT ensures accurate spool position control. Vibration and shock tested. Standard 24V DC supply with wide tolerance band. Wide range of spool and flow rate options. Standard ± 1V DC and 4-2m command signals. Installation wiring reduced and simplified. Standard 7-pin connector. Simple valve removal and replacement for service. Supported by auxiliary function modules. Full CE electromagnetic compatibility /3/EU IP65 and IP67 environmental protection rating. Optional valve enable function. Optional pilot pressure reducer. Typical section view KHDG5V-7, 12 design KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September

4 Model code K H D G 5 V -*- ********* (E)X T ** *** - H 4 ** Valve type K 2 Integral amplifier Proportional valve 3 Feedback arrangement H 4 Control type D 5 Mounting G 6 Operation Integral amplifier series From pilot and main stages Directional valve Subplate mounted 4 Solenoid controlled, pilot operated 7 Pressure rating V 31 bar (45 psi) Size 5 35 bar (5 psi) Size 7 35 bar (5 psi) Size 8 35 bar (5 psi) Size 1 8 Interface ISO Size 5 7 Size 7 8 Size 8 1 Size 1 9 Spool type, flow rating and metering See Functional Symbol on page 7. per metering flow path, e.g. to T. Symmetric spools for KHDG5V-5 valves: 2CN L/min (26 US gpm) 33C8N 8 L/min (21 US gpm) 5C85N 85 L/min (22 US gpm) p = 5 bar (72 psi) For KHDG5V-1 valves: 2C7N 7 L/min (185 US gpm) 33C7N 7 L/min (185 US gpm) 5C72N 72 L/min (19 US gpm) symmetric spools First figure (***N) is flow rating, or -T ( port flow); last figure (N***) is flow rating P-, or -T ( port flow) For KHDG5V-5 valves: 2C7N45 7 L/min (18.5 US gpm), port flow 45 L/min (11.9 US gpm), port flow 33C6N4 6 L/min (17.2 US gpm), port flow 4 L/min (1.6 US gpm), port flow PQ87F See flow charts (p.11) For KHDG5V-7 valves: 2C15N85 15 L/min (4 US gpm), port flow; +85 L/min (22.4 US gpm), port flow 33C13N65 13 L/min (33.3 US gpm), port flow; 65 L/min (17.2 US gpm), port flow 5C2N115 2 L/min (52.8 US gpm), port flow; 115 L/min (3.8 US gpm), port flow PQ19F See flow charts (p.11) For KHDG5V-8 valves: 2C375N L/min (99 US gpm), port flow; 25 L/min (66 US gpm), port flow 12C375N25 33C375N25 133C375N25 733C375N25 72C375N25 PQ375F 375 L/min (99 US gpm), port flow; 25 L/min (66 US gpm), port flow 375 L/min (99 US gpm), port flow; 25 L/min (66 US gpm), port flow 375 L/min (99 US gpm), port flow; 25 L/min (66 US gpm), port flow 375 L/min (99 US gpm), port flow; 25 L/min (66 US gpm), port flow 375 L/min (99 US gpm), port flow; 25 L/min (66 US gpm), port flow See flow charts (p.12) For KHDG5V-7 valves: 2C2N 2 L/min (52 US gpm) 33C16N 16 L/min (42 US gpm) 5C2N 2 L/min (52 US gpm) For KHDG5V-8 valves: 2C375N 375 L/min (99 US gpm) 33C375N 375 L/min (99 US gpm) 5C375N 375 L/min (99 US gpm) 4 KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September 217

5 Model code For KHDG5V-1 valves: 2C7N42 7 L/min (185 US gpm), port flow; 42 L/min (11 US gpm), port flow 33C7N42 7 L/min (185 US gpm), port flow; 42 L/min (11 US gpm), port flow 12C7N42 7 L/min (185 US gpm), port flow; 42 L/min (11 US gpm), port flow 133C7N42 7 L/min (185 US gpm), port flow; 42 L/min (11 US gpm), port flow 72C7N42 7 L/min (185 US gpm), port flow; 42 L/min (11 US gpm), port flow 733C7N42 7 L/min (185 US gpm), port flow; 42 L/min (11 US gpm), port flow PQ68 F See flow charts (p.13) For actual maximum flows refer to power capacity envelopes, page 1. 1 Pilot supply lank E X EX Internal (without reducer) External (without reducer) Internal (with reducer) External (with reducer) See section on maximum pressures (page 9) for when pilot reducer must be used. 12 Electrical control signal M1 M2 M3 M4 13 Electrical connection PE7 PH7 14 Coil rating H +/-1V command and +/-1V feedback 4-2m command and +/-1V feedback +/-1V command and 4-2m feedback 4-2m command and 4-2m feedback 7 pin connector with plug s PE7 but with pin C used for enable signal 24 VDC amplifier supply 15 Port T pressure limit rating 4 5 bar (7 psi) (for internal pilot drain option only, item 11 above) 16 Design number series Note: dditional configurations available upon request. Please contact you customer sales representative for details. 11 Pilot drain T Internal Omit for external drain WRNING Valves with integral amplifiers are supplied with or without the metal 7-pin plug. The Eaton plug, part no , must be correctly fitted to ensure that the EMC rating and IP67 rating are achieved. The plug retaining nut must be tightened with a torque of Nm ( lbf ft) to effect a proper seal. KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September

6 Spool data Spool type and flow ratings Valves with 5C spools are designed so that with the valve disabled the pressure in port is at least twice that in port (blocked ports). pplication notes Main-spool options Spools shown are meter-in/meter-out types. Center-condition options are types 2, 33, 5, 12, 133, 72, 733 and PQ. Internally Piloted Models Differ from detailed symbols above by omission of plug and the blocking of port X by the mating surface. Internally pilot drain models Differ from detailed symbols above by omission of plug and blocking of port Y by the mating surface. Symmetric spools ase line pressure drop øp =5 bar (72 psi) per metering flow path, e.g. to T. For actual maximum flow refer to power capacity envelope curves. symmetric spools Figure preceding metering type designator, N e.g. 2C**N) is flow rating P, or T ( port flow): Figure after N (N***) is flow rating P, or T ( port flow). Symmetric Spool code Spool symbol Flow rating For KHDG5V-5 valves: 2CN 2C L/min (26 USgpm) 33C8N 33C 8 L/min (21 USgpm) 5C85N 5C 85 L/min (22 USgpm) For KHDG5V-7 valves: 2C2N 2C 2 L/min (52 USgpm) 33C16N 33C 16 L/min (42 USgpm) 5C2N 5C 2 L/min (52 USgpm) For KHDG5V-8 valves: 2C375N 2C 375 L/min (99 USgpm) 33C375N 33C 375 L/min (99 USgpm) 5C375N 5C 375 L/min (99 USgpm) For KHDG5V-1 valves: 2C7N 2C 7 L/min (185 USgpm) 33C7N 33C 7 L/min (185 USgpm) 5C72N 5C 72 L/min (19 USgpm) Functional symbol 7-pin plug P T Symplified symbol P T P T plug plug X P T Y Detailed symbol 6 KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September 217

7 Spool data Spool symbols symmetric Spool code Spool symbol Flow rating For KHDG5V-5 valves: 2C7N45 2C 7 L/min (18.5 USgpm) port flow 45 L/min (11.9 USgpm) port flow 33C6N4 33C 6 L/min (17.2 USgpm) port flow 4 L/min (1.6 USgpm) port flow PQ87F PQ See flow chart (p. 11) For KHDG5V-7 valves: 2C15N85 2C 15 L/min (4 USgpm) port flow 85 L/min (22.4 USgpm) port flow 33C13N65 33C 13 L/min (33.3 USgpm) port flow 65 L/min (17.2 USgpm) port flow 5C2N115 5C 2 L/min (52.8 USgpm) port flow, 115 L/min (3.8 USgpm) port flow PQ19F PQ See flow chart (p. 11) For KHDG5V-8 valves: 2C375N25 2C 375 L/min (99 USgpm) port flow 25 L/min (66 USgpm) port flow 33C375N25 33C 375 L/min (99 USgpm) port flow 25 L/min (66 USgpm) port flow 12C375N25 12C 375 L/min (99 USgpm) port flow 25 L/min (66 USgpm) port flow 133C375N25 133C 375 L/min (99 USgpm) port flow 25 L/min (66 USgpm) port flow 72C375N25 72C 375 L/min (99 USgpm) port flow 25 L/min (66 USgpm) port flow 733C375N25 733C 375 L/min (99 USgpm) port flow 25 L/min (66 USgpm) port flow PQ375F PQ See flow chart (p. 12) For KHDG5V-1 valves: 2C7N42 2C 7 L/min (185 USgpm) port flow 42 L/min (11 USgpm) port flow 33C7N42 33C 7 L/min (185 USgpm) port flow 42 L/min (11 USgpm) port flow 12C7N42 12C 7 L/min (185 USgpm) port flow 42 L/min (11 USgpm) port flow 133C7N42 133C 7 L/min (185 USgpm) port flow 42 L/min (11 USgpm) port flow 72C7N42 72C 7 L/min (185 USgpm) port flow 42 L/min (11 USgpm) port flow 733C7N42 733C 7 L/min (185 USgpm) port flow 42 L/min (11 USgpm) port flow PQ68F PQ See flow chart (p. 13) vailable spools for KHDG5V P T Spool type 2C P T Spool type 5C (zero lapped) P T Spool type 133C P T Spool type 733C P T Spool type 33C P T Spool type 12C P T Spool type 72C P T Spool type PQ KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September

8 Operating data Data is typical with fluid at 36 cst (168 SUS) and 5 C (122 F). Power supply 24V DC (18V to 36V including 1% peak-to-peak max. ripple) max current 3 Command signal Voltage mode to 1V DC, or to 1V DC, or 1V to + 1V DC Input impedance M1: 47 kω - M2: R Common mode voltage to pin D 18V (max) Current mode 4-2 m Max differential voltage to pin E to pin 1V Valve enable signal for model codes PH7 Enable >8.5V (36V max) Disable <6.5V Input impedance 1 kω 7-pin plug connector Pin Description G Power supply positive (+) F E C Power supply V C Not connected (PE7) C Valve enable (PH7) D Command signal (+V or current in) E Command signal (-V or current command return) D View of pins of fixed half. F Output monitor G Protective ground Electromagnetic compatibility (EMC) Conducted Emissions CISPR Ed 6./EN Class, 15kHz to 3MHz Radiated Emissions CISPR Ed 6. /EN Class, 3MHz 1GHz RF Continuous Conducted disturbances IEC 6-4-6, Class 15 KHz to 8 MHz DC Power Port : 1Vrms Signal/Control Port : 1Vrms RF Electromagnetic Field, 8 MHz to 27 MHz, 1V/m, Meets Criterion Surge: IEC DC Power Port : ±1kV Signal/Control Port : ±1kV Electrical Fast Transients IEC 6-4-4, Class DC Power Port : ±2kV Signal/Control Port : ±1kV Electrostatic discharges (ESD) IEC 6-4-2, Class ir ±8kV, Contact ±4kV Threshold command voltage (minimum voltage for minimum flow) V 5C Spools.25V 2C & 33C Spools Monitor signal (pin F) Voltage mode +/- 1V DC for full stroke Output impedance 1KOhm Current mode 4m to 2m Output impedance Upto 2 ohms Power stage PWM frequency 1 khz nominal Step input response, with flow through P T, p=5 bar Time to reach 9% of required step: (72 psi) per metering path, e.g. P, pilot pressure = 4 bar Required flow step: KHDG5V 5 KHDG5V 7 KHDG5V 8 KHDG5V 1 to % 24 ms 24 ms 33 ms 64 ms % to 23 ms 23 ms 33 ms 6 ms +9 to 9% 35 ms 36 ms 49 ms 84 ms Reproducibility, valve-to-valve (at factory settings): 5% Flow at % command signal Hysteresis with flow through --T <1% Øp=5 bar (72 psi) per metering path (P or T) Protection: Electrical Reverse polarity protected Environmental IEC 6529, Class IP65 & IP67 mbient air temperature range for full performance -4 C to +85 C (-4 F to 185 F) Oil temperature range for full performance C to 7 C (32 F to 158 F) 8 KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September 217

9 Pressure and minimum flow rates Minimum temperature at which valves will work at reduced performance -4 C (-4 F) Storage temperature range -4 C to +85 C (-4 F to 185 F) Relative duty factor Continuous rating (ED = %) Mass: kg (lb) approx. KHDG5V 5 KHDG5V 7 KHDG5V 8 KHDG5V 1 Valves with pressure reducer 1.15 (22.4) 11.4 (25.1) 17.5 (37.54) 44.3 (97.7) Valves without pressure reducer 8.85 (19.5) 1.1 (22.2) (34.84) 43.1 (95.1) Supporting products: uxiliary electronic modules (DIN -rail mounting): EH-CON-21-2* signal converter See catalog G 241 EHD-DSG-21--1* command signal generator See catalog G 247 EH-RMP-21--2* Ramp generator See catalog G 241 EH-PSU Power supply See catalog G 241 EH-PID PID controller See catalog G 2427 Maximum pressures, bar (psi) valves with pressure reducer Model Pilot pressure source Pilot drain connection P Port & Ports T Port X Port Y Port KHDG5V 5 External External 315 (45) 315 (45) 21 (3) 315 (45) 5 (7) Internal* 315 (45) 315 (45) 5 (7) 315 (45) 5 (7) Internal External 315 (45) 315 (45) 21 (3) 315 (45) 5 (7) Internal* 315 (45) 315 (45) 5 (7) 315 (45) 5 (7) KHDG5V 7/8/1 External External 35 (5) 35 (5) 35 (5) 35 (5) 5 (7) Internal* 35 (5) 35 (5) 5 (7) 35 (5) 5 (7) Internal External 35 (5) 35 (5) 35 (5) 35 (5) 5 (7) Internal* 35 (5) 35 (5) 5 (7) 35 (5) 5 (7) Minimum recommended pilot operating pressure = 5 bar (7 psi) * Internal drain is a non-preferred option For pilot pressures 21 bar (3 psi) a pilot pressure reducer is optional For pilot pressures > 21 bar (3 psi) a pilot pressure reducer must be used Unused pilot port: Maximum pressure as shown Maximum pressures, bar (psi) valves without pressure reducer Pilot pressure Pilot drain source Pilot drain connection P Port & Ports T Port X Port Y Port KHDG5V 5 External External 315 (45) 315 (45) 21 (3) 21 (3) 5 (7) Internal* 315 (45) 315 (45) 5 (7) 21 (3) 5 (7) Internal External 21 (3) 315 (45) 21 (3) 21 (3) 5 (7) Internal* 21 (3) 315 (45) 5 (7) 21 (3) 5 (7) KHDG5V 7/8/1 External External 35 (5) 35 (5) 35 (5) 21 (3) 5 (7) Internal* 35 (5) 35 (5) 5 (7) 21 (3) 5 (7) Internal External 21 (3) 35 (5) 35 (5) 21 (3) 5 (7) Minimum recommended pilot operating pressure = 5 bar (7 psi) * Internal drain is a non-preferred option For pilot pressures 21 bar (3 psi) a pilot pressure reducer is optional For pilot pressures > 21 bar (3 psi) a pilot pressure reducer must be used Unused pilot port: Maximum pressure as shown Internal* 21 (3) 35 (5) 5 (7) 21 (3) 5 (7) Minimum recommended flow rates Valve size/spool code Min. Flow rate L/min In 3 /min KHDG5V KHDG5V KHDG5V KHDG5V KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September

10 Performance curves KHDG5V-5/7/8/1 Flow gain t p = 5 bar (72 psi) per metering path (e.g. ), with flow through --T or P---T. Percentage command signals applicable for positive and negative values of command signal. Valve Pressure drop bar US gpm KHDG5V 5 Power capacity envelope Flow through --T or P---T KHDG5V 7 KHDG5V Flow rate L/min KHDG5V psi t other p values, flow rates approximate to: px QX = QD pd where QD= Datum flow rate pd= Pressure drop at datum flow rate px= Required p Limited by valve power capacity. Refer to curves on page 11. "2C" Spools KHDG5V 1 2C7N KHDG5V 8 2C375N KHDG5V 7 2C2N KHDG5V 5 2CN between ports & or &, as % of port P pressure % % 2 Spool stroke 4 6 from null, % of max "5C" Spools KHDG5V 1 5C72N KHDG5V 8 5C375N KHDG5V 7 5C2N KHDG5V 5 5CN mplitude ratio (d) Frequency response, Typical For an amplitude of 5 ± 25% of rated flow (ISO 177-1) 2C spool measured at = 36 cst (168 SUS), t = 5 C (122 F) and pilot pressure = 4 bar (with-reducer model) mplitudes KHDG5V Phase lags Frequency (Hz) KHDG5V 8 KHDG5V 1 KHDG5V 5/7 KHDG5V 8 (middle) KHDG5V 5/7 Phase lag (degrees) "33C" Spools KHDG5V 1 33C7N KHDG5V 8 33C375N KHDG5V 7 33C16N KHDG5V 5 33C8N KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September 217

11 Performance curves Flow gain KHDG5V-5 KHDG5V-7 8 2C7N C15N T P- -T T P- -T C6N C13N T P- -T T P- -T PQ87F T 6 -T 4 2 P PQ19F T -T 5 P KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September

12 Performance curves Flow gain KHDG5V C375N25 & 33C375N T P T C375N25 & 733C375N T T P C375N25 & 133C375N T P PQ 375F T -T Flowrate US gpm 5 P Command signal (% of max ) 12 KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September 217

13 Performance curves Flow gain KHDG5V-1 2C7N42 & 33C7N P- 12 -T 3 -T C7N42 & 733C7N T P T C7N42 & 133C7N T P PQ T -T P KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September

14 Installation dimensions KHDG5V-5/7 Dimensions shown in mm (in). KHDG5V-5 Valve without pressure reducer Valve with pressure reducer 1 13,95 ( 4. 49) i r leed Scr ew i r leed Scr ew 22,83 ( 7. 99) 242,86 ( 9. 56) Pressu re Redu cer 4. (1.58) 35, ( 1. 38) 7, (2. 76) 141,6 ( 5. 57) 264,6 ( 1. 42) Mounting surface, seals supplied. For mating surface dimensions, see page 16. For mounting subplate options and bolt options, see catalog G KHDG5V-7 Valve without pressure reducer Valve with pressure reducer 21,83 ( 8.3) 12,17 (4.73) i r leed Scr ew 25,69 (9.87) i r leed Screw Pressure Reducer 4. (1.58) 46, (1.81) 92, (3.62) 142,3 (5.6) 277,47 (1.92) Mounting surface, seals supplied. For mating surface dimensions, see page 16. For mounting subplate options and bolt options, see catalog G KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September 217

15 Installation dimensions KHDG5V-8/1 Dimensions shown in mm (in). KHDG5V-8 Valve without pressure reducer Valve with pressure reducer (11.55) (5.263) ir leed Scr ew (12.635) ir leed Scr ew Pressure Reducer 4. (1.58) 98.4 (3.874) (7.748) (8.887) (19.969) Mounting surface, seals supplied. For mating surface dimensions, see page 17. For mounting subplate options and bolt options, see catalog G KHDG5V-1 Valve without pressure reducer Valve with pressure reducer (5.88) ir leed Screw (8.94) ir leed Screw 267,1 [1.5] Pressure Reducer 4. (1.58) 6. (2.36) (4.66) (6.34) (13.44) Mounting surface, seals supplied. For mating surface dimensions, see page 17. For mounting subplate options and bolt options, see catalog G KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September

16 Mounting surfaces Dimensions shown in mm (in). General description When a subplate is not used, a machined pad must be provided for valve mounting. Pad must be flat within.127 mm (.5 inch) and smooth within 1.6 mm (63 microinch). Mounting bolts, when provided by customer, should be ISO 898 class 12.9 or better. olt Kits See page 18. Dimensional tolerances Dimensional tolerance on interface drawings is.2 mm (.8 ) except where otherwise stated. ISO 441 specifies inch conversion to.1 Conversion from metric ISO 441 gives dimensions in mm. Inch conversions are accurate to.1 unless otherwise stated. Mounting bolt tappings ISO 441 gives metric thread tappings. lternate UNC tappings are Eaton recommendations that allow these plates and associated valves to be used up to their maximum pressures, when using Eaton recommended bolt kits, or bolts of an equivalent strength. It is recommended that Customer s own manifold blocks for UNC bolts should be tapped to the minimum depths given in the footnotes. 6,3 (.25) 21,4 32,5 (.84) (1.28) 5,8 (2.) 27, (1.6) 16,7 (.66) 3,2 (.12) 5 ports Ø 11,2 (.44 dia) including optional tank port T P T 37,3 (1.47) 4 holes, M6-6H x 16 (.63) min. full thread depth 69, (2.72) min. 46,±,1 (1.81±.4) 11, (.433) 8, (.315) X T 62, (2.44) P T Y ISO standard size 5 with ports X and Y This interface conforms to ISO , NSI/ 93.7M (and NFP) size 5, CETOP R35H4 2-5, DIN 2434 Form 1. 1/4-2 UNC-2 optional. 54,±,1 (2.12±.4) 9, (3.54) min. Optional port (T) Hole Ø 6,3 (.25 dia) max. 1,6±,1 (.63±.4) 15,9 (.63) 18,3 (.72) 11,6±,1 (4. ±.4) 88,1 (3.47) 76,6 (3.16) 65,9 (2.59) 5, (1.97) 34,1 (1.34) 2 holes Ø 4, (.157 dia) x 8, (.31) min. depth 4 holes M1 x 17, (.67) min. full thread depth ISO standard size 7 interface This interface conforms to: ISO NSI/ 93.7M (and NFP) size 7 CETOP R35H4.3-7 DIN 2434 Form 16 3/8-16 UNC optional. 1/4-2 UNC optional. 69,9 ±,1 ( ,5 ±.4) ±,1 (2.815 ±.4) 57,2 (2.25) 55,6 (2.19) 34,9 (1.38) 14,3 (.56) L T P X Y 95, (3.74) min. 3 holes (ports L, X, Y) Ø 6,3 (.25 dia) max. 11, (.43) 13, (5.12) min. 4 holes (ports P, T,, ) Ø 17,5 (.69 dia) max. 2 holes M6-6H x 17, (.67) min. full thread depth 16 KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September 217

17 Mounting surfaces Dimensions shown in mm (in). 53,2 ±,1 (2.94 ±.4) 29,4 ±,1 (1.157 ±.4) 13,2 ±,1 (5.126 ±.4) 112,7 (4.437),8 (3.968) 94,5±,1 (3.72 ±.4) 77, (3.3) 2 holes Ø 7,5 (.295 dia) x 8, (.31) min. depth Ports X,Y: Ø 11,2 (.44 dia) max. ISO standard size 8 Interface This interface conforms to: ISO NSI/ 93.7M (and NFP) size 8 CETOP R35H4.3-8 DIN 2434 Form 25 1/2-13 UNC optional. 17,5 (.689) 19, (.748) 17,5 (.689) 5,6 (.22) 4,8 ±,1 (.189±.4) 92,1±,1 (3.626±.4) 74,6 (2.937) 73, (2.874) 46, (1.181) L X T P Y 118, (4.65) min. 153, (6.2) min. Port L: Ø 11,2 (.44 dia) max. 6 holes, M12-6H x 2, (.78) Ports P, T,, : min. full th read depth Ø 25. (.98 dia) max [4.5] 41.3 [1.62] 76.2 [3.] 23.1 [9.6] 19.5 [7.5] [6.62] [5.81] [5.46] 82.6 [3.25] 7.1 Dia [.28] Dia 3-Places ISO standard size 1 interface This interface conforms to: ISO NSI/ 93.7M (and NFP) size 1, CETOP 35H4.3-1, DIN 2434 Form [6.25] [1.75] [1.38] T P Y M2 Thread [Optional UNC Thread] Ports X, Y, L 11.2 Dia [.44] Dia 3-Places 13.2 [5.12] 79.4 [3.12] L [7.83] [4.88] X Ports P, T,, 32. Dia (Max) [1.26] Dia (Max) KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September

18 Electrical information lock diagram Voltage input (M1) KHDG5V wiring Connections must be made via the 7-pin plug mounted on the amplifier. See page 18 of this leaflet and Eaton s Installation Wiring Practices for Eaton Electronic Products, leaflet Recommended cable sizes are: Power cables: For 24V supply.75 mm2 (18 WG) up to 2m (65 ft) 1. mm2 (16 WG) up to 4m (13 ft) Signal cables:.5 mm2 (2 WG) Screen (shield): See connection diagram on page 2. KHDG5V wiring Wiring details for these valves are contained in the appropriate Eurocard literature and the Installation Wiring Practices for Eaton Electronic Products leaflet Command signals and outputs, M1 7-pin plug Flow direction Pin D Pin E Positive OV OV Negative P to U d - U e = Positive Negative OV OV Positive P to U d - U e = Negative suitable cable would have 7 cores, a separate screen for the signal wires and an overall screen. Cable outside diameter mm ( inches) 7-pin plug connections +24V Power V Enable or C not connected +15V V 15V +24V LVDT Compensation network Monitor output F Modulator Command signal voltage, see table Non-inverting Inverting D E Gain Of fset Protective ground G Valve envelope +24V Solenoid drive Pin C is used for a valve enable signal with electrical connections PH7 WRNING ll power must be switched off before connecting or disconnecting any plugs. 18 KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September 217

19 Electrical information lock diagram Current input (M2) KHDG5V KHDG5V wiring Connections must be made via the 7-pin plug mounted on the amplifier. See page 19 of this leaflet and Eaton s Installation Wiring Practices for Eaton Electronic Products, leaflet Recommended cable sizes are: Power cables: For 24V supply.75 mm2 (18 WG) up to 2m (65 ft) 1. mm2 (16 WG) up to 4m (13 ft) Signal cables:.5 mm2 (2 WG) Screen (shield): suitable cable would have 7 cores, a separate screen for the signal wires and an overall screen. Cable outside diameter mm ( inches) See connection diagram on page 21. KHDG5V wiring Wiring details for these valves are contained in the appropriate Eurocard literature and Eaton s Installation Wiring Practices for Eaton Electronic Products leaflet Command signals and outputs, M2 7-pin plug Pin D Pin E Pin Flow direction More than 12 m Current return Power ground P to Less than 12 m Current return Power ground P to 7-pin plug connections LVDT Compensation network +24V Power V Enable or C not connected +15V V -15V +24V Monitor Output F Command +4 to 2 m D F1 R1 Modulator Return E F2 Gain Offset Protective ground G Valve envelope +24V Solenoid drive R1 F1, F2 Pin C is used for a valve enable signal with electrical connections PH7. Shunt resistor R Resettable fuse WRNING ll power must be switched off before connecting/ disconnecting any plugs. KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September

20 Electrical information Wiring connections voltage input (M1) Spool position monitor voltage (pin F) will be referenced to the K valve local ground. Power Supply User Panel +24V V Outer Screen K..PE7 valve Demand Signal Spool Position Monitor V ±1V V Input Inner Screen Drain Wire C D or E E or D G F Valve must be connected to ground via subplate Enclosure V must be connected to ground Connector shell Wiring connections for M1 valves with enable feature N ote: In applications where the valve must conform to European RFI/EMC regulations, the outer screen (shield) must be connected to the outer shell of the 7 pin connector, and the valve body must be fastened to the earth ground. Proper earth grounding practices must be observed in this case, as any differences in command source and valve ground potentials will result in a screen (shield) ground loop. User Panel Outer Screen K.. PH7 valve Power Supply +24V V Enable Signal Demand Signal Spool Position Monitor V +8.5V to 36V V ±1V V Input Inner Screen Drain Wire C D or E E or D G F Valve must be connected to ground via subplate Enclosure V must be connected to ground Connector shell 2 KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September 217

21 Electrical information Wiring connections current input (M2) Spool position monitor voltage (pin F) will be referenced to the K valve local ground. Power Supply Demand Signal Spool Position Monitor Enclosure User Panel V must be connected to ground +24V V V 4-2 m V Input Outer Screen Inner Screen Drain Wire Wiring connections for M2 valves with enable feature K.. PE7 valve N ote: In applications where the valve must conform to European RFI/EMC regulations, the outer screen (shield) must be connected to the outer shell of the 7 pin connector, and the valve body must be fastened to the earth ground. Proper earth grounding practices must be observed in this case, as any differences in command source and valve ground potentials will result in a screen (shield) ground loop. C E D G F Valve must be connected to ground via subplate Connector shell WRNING Electromagnetic Compatibility (EMC) It is necessary to ensure that the valve is wired up as above. For effective protection the user electrical cabinet, the valve subplate or manifold and the cable screens should be connected to efficient ground points. The metal 7 pin connector part no should be used for the integral amplifier. In all cases both valve and cable should be kept as far away as possible from any sources of electromagnetic radiation such as cables carrying heavy current, relays and certain kinds of portable radio transmitters, etc. Difficult environments could mean that extra screening may be necessary to avoid the interference. It is important to connect the V lines as shown above. The multi-core cable should have at least two screens to separate the demand signal and monitor output from the power lines. The enable line to pin C should be outside the screen which contains the demand signal cables. User Panel Outer Screen K.. PH7 valve Power Supply +24V V Enable Signal Demand Signal Spool Position Monitor V +8.5V to 36V V 4-2 m V Input Inner Screen Drain Wire C E D G F Valve must be connected to ground via subplate Enclosure V must be connected to ground Connector shell KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September

22 pplication data Fluid cleanliness Proper fluid condition is essential for long and satisfactory life of hydraulic components and systems. Hydraulic fluid must have the correct balance of cleanliness, materials and additives for protection against wear of components, elevated viscosity and inclusion of air. Recommendations on contamination control methods and the selection of products to control fluid condition are included in Eaton publication 9132 or 561, Eaton Guide to Systemic Contamination Control. The book also includes information on the Eaton concept of Proctive Maintenance. The following recommendations are based on ISO cleanliness levels at 2 μm, 5 μm and 15 μm For products in this catalog the recommended levels are: to 7 bar ( psi) 18/16/ bar ( + psi) 17/15/12 Eaton products, as any components, will operate with apparent satisfaction in fluids with higher cleanliness codes than those described. Other manufacturers will often recommend levels above those specified. Experience has shown, however, that life of any hydraulic components is shortened in fluids with higher cleanliness codes than those listed above. These codes have been proven to provide a long trouble-free service life for the products shown, regardless of the manufacturer. Hydraulic fluids Materials and seals used in these valves are compatible with antiwear hydraulic oils, and non-alkyl-based phosphate esters. The extreme operating viscosity range is 5 to 13 cst (227 to 7 SUS) but the recommended running range is 54 to 13 cst (245 to 7 SUS). For further technical information about fluids see Technical Information leaflet -92 or I-286S. Installation The proportional valves in this catalog can be mounted in any attitude, but it may be necessary in certain demanding applications, to ensure that the solenoids are kept full of hydraulic fluid. Good installation practice dictates that the tank port and any drain port are piped so as to keep the valves full of fluid once the system start-up has been completed. Service information The products from this range are preset at the factory for optimum performance; disassembling critical items would destroy these settings. It is therefore recommended that should any mechanical or electronic repair be necessary they should be returned to the nearest Eaton repair center. The products will be refurbished as necessary and retested to specification before return. Field repair is restricted to the replacement of the seals. Note: The feedback/solenoid assembly installed in this valve should not be disassembled. 22 KHDG5V PROPORTIONL TWO-STGE DIRECTIONL VLVES V-VLDI-MC1-E3 September 217

23 Eaton Hydraulics Operations US Lone Oak Road Eden Prairie, MN US Tel: Fax: Eaton Hydraulics Operations Europe Route de la Longeraie Morges Switzerland Tel: +41 () Fax: +41 () Eaton Hydraulics Operations sia Pacific 11th Floor Hong Kong New World Tower 3 Huaihai Zhong Road Shanghai 221 China Tel: Fax: Eaton Eaton oulevard Cleveland, OH United States Eaton.com 217 Eaton ll Rights Reserved Printed in XXX Publication No. V-VLDI-MC1-E3 / 3826 September 217 Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations. Eaton is a registered trademark. ll trademarks are property of their respective owners.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

Directional Controls

Directional Controls Vickers Directional Controls Lever Operator Directional Control Valves DG17S-8-**-10 DG17S4-10 **-50 NF D08/D10, ISO-4401-08/10 Released 5/94 681 able of Contents General Information..................................................................................

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

Applications. What moves your world

Applications. What moves your world Digital Control Proportional Valves Series D92 High-performance pressure control valve with high dynamics and the ability to easily and exactly tune the pressure controller gain The pq-proportional valves

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94 Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi) Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for

More information

D680 Series Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

D680 Series Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 D68 Series roportional Control Valves with Integrated Electronics ISO 441 Size 5 to 1 GENERL D681- D685 SECION GE MOOG SERVO- ND ROORIONL CONROL VLVES General 2 enefits and Functionality 3 General echnical

More information

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options. Catalog HY14-255/US echnical Information ilot Operated ressure Reducing Valves Series VMY*6 General Series VMY*6 valves consist of the main stage with valve spools and the pilot stage with the proportional

More information

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US

More information

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm) Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B

VICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B VICKERS SystemStak Valves ISO 441-3; NF-D3; 315 bar (45 psi); 6 L/min (15.7 USgpm) 1 G 227 uild a Compact, Cost-Effective, Reliable Hydraulic System with Vickers SystemStak Valves Reduces System Space

More information

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

Leak-Free Load-Control Valve SAE ½ psi flange

Leak-Free Load-Control Valve SAE ½ psi flange Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control

More information

SystemStak Valves. ISO4401 Size 02

SystemStak Valves. ISO4401 Size 02 SystemStak Valves ISO441 Size 2 Reduce System Space Requirements SystemStak valves make compact hydraulic systems in which specific function valves are sandwich mounted between a directional valve and

More information

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

Picture. Minimum cable bending radius 100 mm [4] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables) Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring

More information

D680 Series Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

D680 Series Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 D68 Series roportional Control Valves with Integrated Electronics ISO 441 Size 5 to 1 GENERL D 6 8 1 - D 6 8 5 SECION G E MOOG SERVO- ND ROORIONL CONROL V LV E S General 2 enefits and Functionality 3 General

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min

More information

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

Explosion-proof solenoid valves on/off and proportional controls - UL certification

Explosion-proof solenoid valves on/off and proportional controls - UL certification www.atos.com Table E125-10/E Explosion-proof solenoid valves on/off and proportional controls - UL certification DLHZ-T-040 valve body ex-proof solenoid ex-proof transducer (only for proportional -T valves)

More information

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:

More information

Digital directional & flow control valves D-DF(R)G

Digital directional & flow control valves D-DF(R)G Digital directional & flow control valves D-DF(R)G Functional Symbols Model Code D-DFG- D-DFG-~ D-DFRG-/ D-DFG--C--- Digital directional & flow control valve Size Spool type (neutral position) : ll ports

More information

Servovalves Series BD, PH, SE. Catalogue HY /UK November 2003

Servovalves Series BD, PH, SE. Catalogue HY /UK November 2003 Series BD, PH, SE Catalogue HY11-3292/UK November 2003 Note This document and other information from Parker Hannifin GmbH, its subsidiaries, sales offices and authorized distributors provide product or

More information

PRESSURE SEQUENCE VALVE TYPE UZK

PRESSURE SEQUENCE VALVE TYPE UZK PRESSURE SEQUENCE VALVE TYPE UZK Size 10, 20, 30 31,5 MPa up to 450 dm 3 /min WK 450 414 04. 2000r. Pressure sequence valves type UZK are used for switching a system or part of a system off when a set

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar

Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle bar 692 Differenz-Drucktransmitter Differential pressure transmitter Transmetteur de pression différentielle 0 0.1 25 bar E Technical overview The differential pressure transmitter of type series 692 with

More information

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES 52 000/110 ED This series of modular subplates has been designed to make hydraulic circuits and can be used directly on power packs or on any other section of the machine. The subplates are assembled by

More information

Double Pilot Operated Cartridge Check Valve, Size 8

Double Pilot Operated Cartridge Check Valve, Size 8 Double Pilot Operated Cartridge Check Valve, Size 8 Q max = 7 l/min (19 gpm), p max = 35 bar (5 psi) pilot operated, two-stage, spring-closed cartridge-type poppet valve Compact design for cavity type

More information

2-way flow control valve Model 2FRM 6

2-way flow control valve Model 2FRM 6 R 28 6/0.98 Replaces R 28 62/05.94 R 28 6/06.98 2-way flow control valve Model 2FRM 6 Nominal size 6 Series X Maximum operating pressure 4569 SI (5 bar) ) Maximum flow 8.45 GM (2 L/min) H//D 585/97 + H//D

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

005 Series Modular Valves

005 Series Modular Valves 5 Series Modular Valves ype of Modular Valve Class Graphic Symbols age Solenoid Operated Directional Valve DSG-5- *** - * - ressure Control Valves Flow Control Valves Directional Control Valves Modular

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure a secondary part of a hydraulic circuit. Pressure is mataed

More information

VSD03M DIRECTIONAL CONTROL VALVES

VSD03M DIRECTIONAL CONTROL VALVES NFPA SIZE D03 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e.

More information

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM Catalog HY14-252/US Introduction Series C, CPO, F, PRD, PR, R anapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D3, D5 and D8 sandwich

More information

Target Cleanliness Worksheet. Systemic Contamination Control

Target Cleanliness Worksheet. Systemic Contamination Control Target Cleanliness Worksheet Systemic Contamination Control Target Cleanliness Worksheet 1. SET A TARGET Eaton Recommended Cleanliness Code Chart PUMPS

More information

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing

More information

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE TYPICAL PERFORMANCE SPECIFICATIONS DESCRIPTION These proportional valves are direct operated pressure reducing valves. They can be used to control pressure in parts of a circuit. This valve incorporates

More information

ATM.ECO - Analog Pressure Transmitter

ATM.ECO - Analog Pressure Transmitter Pressure Transmitter ATM.ECO - Analog Pressure Transmitter CUSTOMER BENEFITS Entry level series into precision pressure measurement High measurement accuracy is ensured by sophisticated digital temperature

More information

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1 Pressure reducing valve, direct operated, type DR 5 DP Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pressure reducing valve, direct operated, type DR 5 DP Size 5 up to 31.5MPa up to

More information

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09. Meter out pressure compensator Sandwich plate design Type SCA... /Series X Sizes 6, 5 up to 35 bar up to 35 L/min RE 9 47/.96 RE 9 47/.96 Replaces: 9.87 Sandwich plate design Load compensation in lines

More information

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0) Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW Tel +44 (0)1254 615100 www.allspeeds.co.uk HP690A Intensifier Panel including the following versions: Model Intensification

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

180 Series Rotary Shear Directional Control Valve

180 Series Rotary Shear Directional Control Valve 180 Series Rotary Shear Directional Control Valve Up to l 38 lpm, 10 US gpm l 700 bar, 10,000 psi Milwaukee, WI 53235, US el: +1 (414) 769-6400 sales-us@webtec.com St. Ives, Cambs. E27 3LZ, UK el: +44

More information

MANUAL KPS Pressure Control Valve

MANUAL KPS Pressure Control Valve TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm) Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting

PRESSURE REDUCING (AND CHECK) VALVES RT/RG RCT/RCG. -03/06/10 (3/8, 3/4, 1-1/4) Threaded Connections / Sub-plate Mounting REDUING (ND HEK) VLVES RT/RG RT/RG -3// (3/8, 3/, -/) Threaded onnections / Mounting Up to MPa (5 PSI), 5 L /m in (3 U.S.GPM) Pub. E-3 Pressure Reducing Valves Pressure reducing valves are used to set

More information

Pressure-Relief Cartridge Valve, Size 4

Pressure-Relief Cartridge Valve, Size 4 Pressure-Relief Cartridge Valve, Size 4 Q max = 30 l/min, p max = 420 bar Seated design, direct acting, with mechanical operation Compact construction for cavity type AL 3/4-16 UNF High flow rates 7 pressure

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Size

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders ENGINEERING DT PV Piston Pumps Same Day Shipments of Units or Part Orders Interchangeable Parts Fully Tested w w w. F l u i D y n e F P. c o m Email:cs@FluiDyneFP.com Contents asic characteristics.........................................................................................

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

Mass Flow Meter (MFM) for gases

Mass Flow Meter (MFM) for gases Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners 7 634 VGS1... with AGA67 connector VGS2... with AGA67 connector Solenoid gas valve VGS The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners The VGS and

More information

Pilot Operated Check Valves

Pilot Operated Check Valves Pilot Operated Check Valves These check valves allow flow in one direction and prevent flow in the reverse direction, until operated by pilot pressure to allow free reverse flow. The specified cracking

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available -0 Watts AEH Series s from. V to 8 V xppower.com Non-standard s Available Universal Input Single & Multiple Versions 0 C to +60 C Operating Temperature Efficiency up to 80% Non-standard Connectors Available

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking: direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting

More information

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1... 4/3 Directional valve elements L8L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L8L1...(EDC-LV) RE 1831-17 Edition: 2.216 Replaces: 7.12 Size 6 Series Maximum

More information

Cooler-Bypass Thermostat Valve, Size 16

Cooler-Bypass Thermostat Valve, Size 16 Cooler-Bypass hermostat Valve, Size Q max = l/min, p max = bar emperature-controlled, integral relief function, various pressure settings available Description emperature-dependent bypass control Integral

More information

C-Flow Coriolis Mass Flow Meters

C-Flow Coriolis Mass Flow Meters Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM

More information

P900. P900, Datenblatt Seite 1 DESCRIPTION

P900. P900, Datenblatt Seite 1 DESCRIPTION , Datenblatt Seite 1 Field proven rugged construction High overpressure capability High reliability for demanding environments Application specific customization Excellent media compatibility Shock and

More information

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering

More information

Tightness controls TC 1 3 and TC 4

Tightness controls TC 1 3 and TC 4 Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems

More information

Fail operational controls for an independent metering valve

Fail operational controls for an independent metering valve Failure mode and CMA valves Fail operational controls for an independent metering valve By: Michael Rannow email: michaelrannow@eaton.com Eaton Corporation, 7945 Wallace Rd. Eden Prairie, MN, 55347 As

More information

Pressure transmitters EMP 2

Pressure transmitters EMP 2 Data sheet Pressure transmitters EMP 2 The high accuracy pressure transmitter EMP 2 is designed for monitoring and control in marine and industial applications and offers a reliable pressure measurement,

More information

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS

ATM.1ST. Pressure transmitters CUSTOMER BENEFITS Pressure transmitters ATM.1ST CUSTOMER BENEFITS High precision pressure sensor over the whole temperature range Electronic compensation Modular sensor structure (any process and electrical connections

More information

user leaflet GAUGING TRANSDUCERS

user leaflet GAUGING TRANSDUCERS user leaflet Solartron Metrology Gauging Transducers are high precision measurement probes intended for all gauging applications demanding high accuracy and a high degree of repeatability. The one piece

More information

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces

More information

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual Sensor for Air Bubble Detection at Liquid Filled Tubes SONOCHECK Type ABD06.xx Operating Manual Manufacturer: Model: Type: SONOTEC Ultraschallsensorik Halle GmbH Air Bubble Detector ABD06.xx SONOTEC Ultraschallsensorik

More information

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION 2/2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32 Size 32 up to 42 MPa 700 dm 3 /min WK 490 907 04.1999r. 2/2 way cartridge valve type URZS 32 can be used to build hydraulic systems

More information

Hand & mechanical directional valves

Hand & mechanical directional valves www.atos.com Table E5-3/E Hand & mechanical directional valves ISO 44 sizes 6,, 6 and 25 H- Hand & mechanical operated directional valves are spool type, three or four way, two or three position valves,

More information

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve

Sandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve Technical Information Series PRM General Description Series PRM reducing valves are used to regulate pressure, in one area of a circuit, below normal system pressure. This style valve is well suited to

More information

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119 Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,

More information

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar single stage pumps M/5811 Very high induced air capacity % lower air consumption than comparable single stage units No wearing parts Compatible with a wide range of line contaminants llows direct connection

More information

VLT 2000 Series. How to size your VLT

VLT 2000 Series. How to size your VLT Selection of frequency converter Usually the size of frequency converter is chosen on the basis of the shaft output, as this may be the only value known. However, if the data are known for both the application,

More information

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6 P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,

More information

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

L6090 (LC04M-CBL) - L6095 (LC04M-CBD) or 3 way pressure compensated flow regulators L69 (LC4M-CBL) - L695 (LC4M-CBD) RE 1833-4 Edition:.16 Replaces: 7.1 Size 4 Series Maximum operating pressure 31 bar (45 psi) Maximum flow (-way) 1 l/min (3.

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR

More information