model for functional safety of

Size: px
Start display at page:

Download "model for functional safety of"

Transcription

1 Application of Weibull reliability model for functional safety of electro-hydraulic system 1

2 When the safety of the machinery users relies on a reliable function of the control system, than a safety function is required. Source: 10 steps to Performance Level Performance Level (PL) as integrity measure of a safety function. 2

3 PL determined based on probabilistic quantity PFH D, estimated through Category, Diagnostic Coverage (DC) and MTTF D Source: 10 steps to Performance Level 3

4 λ t λ PFH D : State modelling and reliability models MTTF = 1 λ Time (C OK ) OK R R Haz. situation (C H. ) S (C SAFE ) D (C D. ) safe failure dem dang. failure t D,U PFH D D,D (C DD ) D.U. failure (C DU. ) D.D. failure Exponential failure distribution λ(t) = λ Weibull failure distribution λ t = β 1 η β t β 1 4

5 Approach of this work ISO :2015 Category MTTF D DC avg Figure 5 or Table K.1 PFH D Category Proposed method MTTF D DC avg Internal parameters PFH D 5

6 Approach of this work ISO :2015 Figure 5 or Table K.1 PFH D Category MTTF D DC avg Proposed method Comparison of results Postprocessing Preprocessing Internal parameters Reliability Model Solver Simulation parameters E N t σ PFH D 6

7 Approach of this work ISO :2015 Figure 5 or Table K.1 PFH D Category MTTF D DC avg Proposed method Category η and β W DC T M Postprocessing Preprocessing Internal parameters Reliability Model Solver Simulation parameters E N t σ PFH D 7

8 Estimation of PFH D through discrete event simulation For a cylinder safe stop, a valve which fails open is a dangerous fault PFH D = Average no. of transitions to unsafe state Service time Channel 1 DD DD DU DU Channel 2 CCF Ch 1 Ch 2 Safety function availability DU DD OK DU DD OK Hazard Safe state Operating DU: Dangerous fault, Undetected by control system DD: Dangerous fault, Detected by control system CCF: Common Cause Failures time 8

9 Results obtained by proposed method PL a PL b PL c PL d PL e 9

10 Application example: safety-related stop Directional valve Source: LASHIP - UFSC Redundant hydraulic circuit for safety-function Equivalent to ISO :2015 category 3 Three sets of reliability data for these hydraulic valves Shut-off valve 10

11 Failure probability Application of Weibull reliability model for Failure probability Application example: considered reliability data for hydraulic valves Weibull Weibull Exponential Exponential Time Time Cumulative distribution function of directional valve 1V1 Cumulative distribution function of shut-off valve 0V1 11

12 Application example: Results and analysis PL d PL e No PL defined Service time 12

13 Functional safety for machinery is dependent on reliability; Mechanical, pneumatic and hydraulic systems have high reliability at beginning of service life; This is however not accurately considered by functional safety standards; Method allows estimation of PFH D considering more accurate reliability models for hydraulic systems, such as: Lifetime testing, or Field failure analysis; Better Performance Level (PL) could be claimed, if other conditions are fulfilled; Method opens possibility for further usage of hydraulic components in safety critical applications, as: Complex machinery with many interrelated actuators; Challenging applications as subsea oil and gas industry. 13

14 Thank you for your attention! Contact: Igor Kuhlhoff Bosch Engineering GmbH Steps to Performance Level Available at Amazon 14

PL estimation acc. to EN ISO

PL estimation acc. to EN ISO PL estimation acc. to EN ISO 3849- Example calculation for an application MAC Safety / Armin Wenigenrath, January 2007 Select the suitable standard for your application Reminder: The standards and the

More information

New Thinking in Control Reliability

New Thinking in Control Reliability Doug Nix, A.Sc.T. Compliance InSight Consulting Inc. New Thinking in Control Reliability Or Your Next Big Headache www.machinerysafety101.com (519) 729-5704 Control Reliability Burning Questions from the

More information

Session: 14 SIL or PL? What is the difference?

Session: 14 SIL or PL? What is the difference? Session: 14 SIL or PL? What is the difference? Stewart Robinson MIET MInstMC Consultant Engineer, Pilz Automation Technology UK Ltd. EN ISO 13849-1 and EN 6061 Having two different standards for safety

More information

Safety Manual OPTISWITCH series relay (DPDT)

Safety Manual OPTISWITCH series relay (DPDT) Safety Manual OPTISWITCH series 5000 - relay (DPDT) 1 Content Content 1 Functional safety 1.1 In general................................ 3 1.2 Planning................................. 5 1.3 Adjustment

More information

Safety Manual VEGAVIB series 60

Safety Manual VEGAVIB series 60 Safety Manual VEGAVIB series 60 Contactless electronic switch Document ID: 32002 Contents Contents 1 Functional safety... 3 1.1 General information... 3 1.2 Planning... 4 1.3 Adjustment instructions...

More information

Functional safety. Functional safety of Programmable systems, devices & components: Requirements from global & national standards

Functional safety. Functional safety of Programmable systems, devices & components: Requirements from global & national standards Functional safety Functional safety of Programmable systems, devices & components: Requirements from global & national standards Matthias R. Heinze Vice President Engineering TUV Rheinland of N.A. Email

More information

Safety in pneumatic automation

Safety in pneumatic automation Safety in pneumatic automation Pharm connect congress 2014 Budapest Feb. 26. 27. Thomas Schulz Head of ISM and KAM Biotech/Pharma Phone: +49-711/347-52192 Mail: thss@de.festo.com Thomas Schulz / CP-KB

More information

Safety Manual VEGASWING 61, 63. NAMUR With SIL qualification. Document ID: 52084

Safety Manual VEGASWING 61, 63. NAMUR With SIL qualification. Document ID: 52084 Safety Manual VEGASWING 61, 63 NAMUR With SIL qualification Document ID: 52084 Contents Contents 1 Document language 2 Scope 2.1 Instrument version... 4 2.2 Area of application... 4 2.3 SIL conformity...

More information

Vibrating Switches SITRANS LVL 200S, LVL 200E. Safety Manual. NAMUR With SIL qualification

Vibrating Switches SITRANS LVL 200S, LVL 200E. Safety Manual. NAMUR With SIL qualification Vibrating Switches SITRANS LVL 200S, LVL 200E NAMUR With SIL qualification Safety Manual Contents 1 Document language 2 Scope 2.1 Instrument version... 4 2.2 Area of application... 4 2.3 SIL conformity...

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Solenoid Valves SNMF 532 024 ** ** and SMF 52 024 ** ** Customer: ACG Automation Center Germany GmbH & Co. KG Tettnang Germany Contract No.: ACG

More information

What safety level can be reached when combining a contactor with a circuitbreaker for fail-safe switching?

What safety level can be reached when combining a contactor with a circuitbreaker for fail-safe switching? FAQ 01/2015 What safety level can be reached when combining a contactor with a circuitbreaker for fail-safe switching? SIRIUS Safety Integrated http://support.automation.siemens.com/ww/view/en/40349715

More information

Safety Manual VEGAVIB series 60

Safety Manual VEGAVIB series 60 Safety Manual VEGAVIB series 60 NAMUR Document ID: 32005 Contents Contents 1 Functional safety... 3 1.1 General information... 3 1.2 Planning... 4 1.3 Adjustment instructions... 6 1.4 Setup... 6 1.5 Reaction

More information

Proportional pressure reducing valves with intrinsic fail safe function

Proportional pressure reducing valves with intrinsic fail safe function Proportional pressure reducing valves with intrinsic fail safe function Dr. Jörg Schneider Dr. Jens Krallmann Daniel Ferres 1 1 2 3 4 5 6 Introduction and Motivation PPRVs as pilot valves for sectional

More information

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1* Safety Manual Process pressure transmitter IPT-1* 4 20 ma/hart Process pressure transmitter IPT-1* Contents Contents 1 Functional safety 1.1 General information... 3 1.2 Planning... 4 1.3 Instrument parameter

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Solenoid Drivers KFD2-SL2-(Ex)1.LK.vvcc KFD2-SL2-(Ex)*(.B).vvcc Customer: Pepperl+Fuchs GmbH Mannheim Germany Contract No.: P+F 06/09-23 Report No.:

More information

Neles ValvGuard VG9000H Rev 2.0. Safety Manual

Neles ValvGuard VG9000H Rev 2.0. Safety Manual Neles ValvGuard VG9000H Rev 2.0 Safety Manual 10SM VG9000H en 11/2016 2 Neles ValvGuard VG9000H Rev 2.0 Safety Manual Table of Contents 1 General information...3 1.1 Purpose of the document... 3 1.2 Description

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Abc. X Series Ball Valve Company: Abc. Inc. Sellersville, PA USA Contract Number: Q11/12-345 Report No.: Abc 11/12-345 R001 Version V1, Revision

More information

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual

DeZURIK. KGC Cast Knife Gate Valve. Safety Manual KGC Cast Knife Gate Valve Safety Manual Manual D11036 August 29, 2014 Table of Contents 1 Introduction... 3 1.1 Terms... 3 1.2 Abbreviations... 4 1.3 Product Support... 4 1.4 Related Literature... 4 1.5

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Contact elements Type 8082 and Type 8208 with or without 8602 actuator Customer: R. STAHL Schaltgeräte GmbH Waldenburg Germany Contract No.: Stahl

More information

Neles trunnion mounted ball valve Series D Rev. 2. Safety Manual

Neles trunnion mounted ball valve Series D Rev. 2. Safety Manual Neles trunnion mounted ball valve Series D Rev. 2 Safety Manual 10SM D en 1/2017 2 Neles trunnion mounted ball valve, Series D Table of Contents 1 Introduction...3 2 Structure of the D series trunnion

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Primary Elements Company: Rosemount Inc. (an Emerson Process Management company) Chanhassen, MN USA Contract Number: Q13/04-008 Report No.: ROS 13/04-008

More information

Failure Modes, Effects, and Diagnostic Analysis of a Safety Device

Failure Modes, Effects, and Diagnostic Analysis of a Safety Device Elias Mabook Failure Modes, Effects, and Diagnostic Analysis of a Safety Device Helsinki Metropolia University of Applied Sciences Bachelor of Engineering Degree Programme in Electronics Bachelor s Thesis

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Isolating repeater 9164 Customer: R. STAHL Schaltgeräte GmbH Waldenburg Germany Contract No.: STAHL 16/08-032 Report No.: STAHL 16/08-032 R032 Version

More information

Valve Communication Solutions. Safety instrumented systems

Valve Communication Solutions. Safety instrumented systems Safety instrumented systems Safety Instrumented System (SIS) is implemented as part of a risk reduction strategy. The primary focus is to prevent catastrophic accidents resulting from abnormal operation.

More information

Hydraulic (Subsea) Shuttle Valves

Hydraulic (Subsea) Shuttle Valves SIL SM.009 0 Hydraulic (Subsea) Shuttle Valves Compiled By : G. Elliott, Date: 11/3/2014 Contents Terminology Definitions......3 Acronyms & Abbreviations..4 1. Introduction 5 1.1 Scope 5 1.2 Relevant Standards

More information

Instrumented Safety Systems

Instrumented Safety Systems Instrumented Safety Systems Engineered Valve Systems for Control and Safety Applications HIPPS Final Elements DINO OLIVIERI Mokveld Agent AIS ISA Giornata di studio HIPPS Agenda The loop Final Elements

More information

The Key Variables Needed for PFDavg Calculation

The Key Variables Needed for PFDavg Calculation Iwan van Beurden, CFSE Dr. William M. Goble, CFSE exida Sellersville, PA 18960, USA wgoble@exida.com July 2015 Update 1.2 September 2016 Abstract In performance based functional safety standards, safety

More information

CT433 - Machine Safety

CT433 - Machine Safety Rockwell Automation On The Move May 16-17 2018 Milwaukee, WI CT433 - Machine Safety Performance Level Selection and Design Realization Jon Riemer Solution Architect Safety & Security Functional Safety

More information

Solenoid Valves used in Safety Instrumented Systems

Solenoid Valves used in Safety Instrumented Systems I&M V9629R1 Solenoid Valves used in Safety Instrumented Systems Operating Manual in accordance with IEC 61508 ASCO Valves Page 1 of 7 Table of Contents 1 Introduction...3 1.1 Terms and Abbreviations...3

More information

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL

RESILIENT SEATED BUTTERFLY VALVES FUNCTIONAL SAFETY MANUAL Per IEC 61508 and IEC 61511 Standards BRAY.COM Table of Contents 1.0 Introduction.................................................... 1 1.1 Terms and Abbreviations...........................................

More information

Safety Beyond the Electrics

Safety Beyond the Electrics Safety Beyond the Electrics Tom Eastwood Machine Safeguarding and Robotics Advisor Workplace Safety and Prevention Services Jim Van Kessel Electrical Engineer JVK Industrial Automation Inc. NOTE: This

More information

Safety Circuit Design. Heinz Knackstedt Safety Engineer C&E sales, inc.

Safety Circuit Design. Heinz Knackstedt Safety Engineer C&E sales, inc. Safety Circuit Design Heinz Knackstedt Safety Engineer C&E sales, inc. 1 OBJECTIVE What are some of the soft issues which determine the final effectiveness of the Functional Safety risk reduction measure

More information

Pneumatic QEV. SIL Safety Manual SIL SM Compiled By : G. Elliott, Date: 8/19/2015. Innovative and Reliable Valve & Pump Solutions

Pneumatic QEV. SIL Safety Manual SIL SM Compiled By : G. Elliott, Date: 8/19/2015. Innovative and Reliable Valve & Pump Solutions SIL SM.0010 1 Pneumatic QEV Compiled By : G. Elliott, Date: 8/19/2015 Contents Terminology Definitions......3 Acronyms & Abbreviations..4 1. Introduction 5 1.1 Scope 5 1.2 Relevant Standards 5 1.3 Other

More information

DeZURIK. KSV Knife Gate Valve. Safety Manual

DeZURIK. KSV Knife Gate Valve. Safety Manual KSV Knife Gate Valve Safety Manual Manual D11035 August 29, 2014 Table of Contents 1 Introduction... 3 1.1 Terms... 3 1.2 Abbreviations... 4 1.3 Product Support... 4 1.4 Related Literature... 4 1.5 Reference

More information

SEMI Headquarters 3081 Zanker Road City, State/Country: San Jose, CA, USA San Jose, CA, USA Leader(s):

SEMI Headquarters 3081 Zanker Road City, State/Country: San Jose, CA, USA San Jose, CA, USA Leader(s): Background Statement for SEMI Draft Document 5000 REVISION TO SEMI S2, ENVIRONMENTAL, HEALTH, AND SAFETY GUIDELINE FOR SEMICONDUCTOR MANUFACTURING EQUIPMENT Addition of Related Information to S2: Selection

More information

Achieving Compliance in Hardware Fault Tolerance

Achieving Compliance in Hardware Fault Tolerance Mirek Generowicz FS Senior Expert (TÜV Rheinland #183/12) Engineering Manager, I&E Systems Pty Ltd Abstract The functional safety standards ISA S84/IEC 61511 (1 st Edition, 2003) and IEC 61508 both set

More information

Application of EN ISO in electro-pneumatic control systems

Application of EN ISO in electro-pneumatic control systems Application of EN ISO 13849 1 in electro-pneumatic control systems Hazards and measures against hazards by implementation of safe pneumatic circuits These examples of switching circuits are offered free

More information

DeZURIK Double Block & Bleed (DBB) Knife Gate Valve Safety Manual

DeZURIK Double Block & Bleed (DBB) Knife Gate Valve Safety Manual Double Block & Bleed (DBB) Knife Gate Valve Safety Manual Manual D11044 September, 2015 Table of Contents 1 Introduction... 3 1.1 Terms... 3 1.2 Abbreviations... 4 1.3 Product Support... 4 1.4 Related

More information

Bespoke Hydraulic Manifold Assembly

Bespoke Hydraulic Manifold Assembly SIL SM.0003 1 Bespoke Hydraulic Manifold Assembly Compiled By : G. Elliott, Date: 12/17/2015 Contents Terminology Definitions......3 Acronyms & Abbreviations..4 1. Introduction 5 1.1 Scope 5 1.2 Relevant

More information

High performance disc valves Series Type BA, BK, BW, BM, BN, BO, BE, BH Rev Safety Manual

High performance disc valves Series Type BA, BK, BW, BM, BN, BO, BE, BH Rev Safety Manual High performance disc valves Series Type BA, BK, BW, BM, BN, BO, BE, BH Rev. 2.0 Safety Manual 10SM B Disc en 4/2018 2 High performance disc valves Series, Type BA, BK, BW, BM, BN, BO, BE, BH, Rev. 2.0

More information

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company

TRI LOK SAFETY MANUAL TRI LOK TRIPLE OFFSET BUTTERFLY VALVE. The High Performance Company TRI LOK TRI LOK TRIPLE OFFSET BUTTERFLY VALVE SAFETY MANUAL The High Performance Company Table of Contents 1.0 Introduction...1 1.1 Terms and Abbreviations... 1 1.2 Acronyms... 1 1.3 Product Support...

More information

Eutectic Plug Valve. SIL Safety Manual. SIL SM.015 Rev 0. Compiled By : G. Elliott, Date: 19/10/2016. Innovative and Reliable Valve & Pump Solutions

Eutectic Plug Valve. SIL Safety Manual. SIL SM.015 Rev 0. Compiled By : G. Elliott, Date: 19/10/2016. Innovative and Reliable Valve & Pump Solutions SIL SM.015 Rev 0 Eutectic Plug Valve Compiled By : G. Elliott, Date: 19/10/2016 Contents Terminology Definitions......3 Acronyms & Abbreviations...4 1. Introduction..5 1.1 Scope 5 1.2 Relevant Standards

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Surge Protective Devices D9324S Customer: G.M. International s.r.l Villasanta Italy Contract No.: GM 16/02-055 Report No.: GM 16/02-055 R005 Version

More information

H250 M9 Supplementary instructions

H250 M9 Supplementary instructions H250 M9 Supplementary instructions Variable area flowmeter Safety manual acc. to IEC 61508:2010 KROHNE CONTENTS H250 M9 1 Introduction 3 1.1 Fields of application... 3 1.2 User benefits... 3 1.3 Relevant

More information

Reliability of Safety-Critical Systems 5.1 Reliability Quantification with FTs

Reliability of Safety-Critical Systems 5.1 Reliability Quantification with FTs Reliability of Safety-Critical Systems 5.1 Reliability Quantification with FTs Mary Ann Lundteigen and Marvin Rausand mary.a.lundteigen@ntnu.no &marvin.rausand@ntnu.no RAMS Group Department of Production

More information

THE IMPROVEMENT OF SIL CALCULATION METHODOLOGY. Jinhyung Park 1 II. THE SIL CALCULATION METHODOLOGY ON IEC61508 AND SOME ARGUMENT

THE IMPROVEMENT OF SIL CALCULATION METHODOLOGY. Jinhyung Park 1 II. THE SIL CALCULATION METHODOLOGY ON IEC61508 AND SOME ARGUMENT THE IMPROVEMENT OF SIL CALCULATION METHODOLOGY Jinhyung Park 1 1 Yokogawa Electric Korea: 21, Seonyu-ro45-gil Yeongdeungpo-gu, Seoul, 07209, Jinhyung.park@kr.yokogawa.com Safety Integrity Level (SIL) is

More information

Safety Legislation and Standards

Safety Legislation and Standards Preventa solutions for efficient machine safety Safety Legislation and Standards Catalogue January 2015 How can you fit a 6000-page catalog in your pocket? Schneider Electric provides you with the complete

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Variable area flow meter RAMC Customer: Rota Yokogawa GmbH & Co. KG Wehr Germany Contract No.: Rota Yokogawa 05/04-20 Report No.: Rota Yokogawa 05/04-20

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Digital Output Module Valve DOMV 9478/22-08-51 Company: R. STAHL Schaltgeräte GmbH Waldenburg Germany Contract No.: STAHL 11/01-104 Report No.: STAHL

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Ground Monitoring Device 71**/5, 81**/5, 82**/5 Company: R. STAHL Schaltgeräte GmbH Waldenburg Germany Contract No.: STAHL 11/07-089 Report No.:

More information

Ch.5 Reliability System Modeling.

Ch.5 Reliability System Modeling. Certified Reliability Engineer. Ch.5 Reliability System Modeling. Industrial Engineering & Management System Research Center. - 1 - Reliability Data. [CRE Primer Ⅵ 2-6] Sources of Reliability Data. Successful

More information

Why do I need dual channel safety? Pete Archer - Product Specialist June 2018

Why do I need dual channel safety? Pete Archer - Product Specialist June 2018 Why do I need dual channel safety? Pete Archer - Product Specialist June 2018 To answer this, we need some basic background information. First why is safety needed? Here are 4 good reasons. 1. To Protect

More information

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards.

This manual provides necessary requirements for meeting the IEC or IEC functional safety standards. Instruction Manual Supplement Safety manual for Fisher Vee-Ball Series Purpose This safety manual provides information necessary to design, install, verify and maintain a Safety Instrumented Function (SIF)

More information

L&T Valves Limited SAFETY INTEGRITY LEVEL (SIL) VERIFICATION FOR HIGH INTEGRITY PRESSURE PROTECTION SYSTEM (HIPPS) Report No.

L&T Valves Limited SAFETY INTEGRITY LEVEL (SIL) VERIFICATION FOR HIGH INTEGRITY PRESSURE PROTECTION SYSTEM (HIPPS) Report No. L&T Valves Limited TAMIL NADU SAFETY INTEGRITY LEVEL (SIL) VERIFICATION FOR HIGH INTEGRITY PRESSURE PROTECTION SYSTEM (HIPPS) MAY 2016 Report No. 8113245702-100-01 Submitted to L&T Valves Ltd. Report by

More information

The following gives a brief overview of the characteristics of the most commonly used devices.

The following gives a brief overview of the characteristics of the most commonly used devices. SAFETY RELATED CONTROL SYSTEMS In a previous article we discussed the issues relating to machine safety systems focusing mainly on the PUWER regulations and risk assessments. In this issue will take this

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Temperature transmitter PR5337 / PR6337 / PR7501 with 4..20 ma output Customer: PR electronics A/S Rønde Denmark Contract No.: PR electronics A/S

More information

Safety manual for Fisher GX Control Valve and Actuator

Safety manual for Fisher GX Control Valve and Actuator Instruction Manual Supplement GX Valve and Actuator Safety manual for Fisher GX Control Valve and Actuator Purpose This safety manual provides information necessary to design, install, verify and maintain

More information

Available online at ScienceDirect. Jiří Zahálka*, Jiří Tůma, František Bradáč

Available online at  ScienceDirect. Jiří Zahálka*, Jiří Tůma, František Bradáč Available online at www.sciencedirect.com Scienceirect Procedia Engineering 69 ( 204 ) 242 250 24th AAAM International Symposium on Intelligent Manufacturing and Automation, 203 etermination and Improvement

More information

Implementing Emergency Stop Systems - Safety Considerations & Regulations A PRACTICAL GUIDE V1.0.0

Implementing Emergency Stop Systems - Safety Considerations & Regulations A PRACTICAL GUIDE V1.0.0 Implementing Emergency Stop Systems - Safety Considerations & Regulations A PRACTICAL GUIDE V1.0.0 ~ 2 ~ This document is an informative aid only. The information and examples given are for general use

More information

Safe Machinery Handbook

Safe Machinery Handbook Safe Machinery Handbook Contents Introduction...4 Why safety?...6 Legal framework...10 Risk assessment... 16 Safe design and safeguarding...22 Functional Safety... 30 Control system standards including

More information

Reliability of Safety-Critical Systems Chapter 3. Failures and Failure Analysis

Reliability of Safety-Critical Systems Chapter 3. Failures and Failure Analysis Reliability of Safety-Critical Systems Chapter 3. Failures and Failure Analysis Mary Ann Lundteigen and Marvin Rausand mary.a.lundteigen@ntnu.no RAMS Group Department of Production and Quality Engineering

More information

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6

SIL Safety Manual. ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases. Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6 ULTRAMAT 6 Gas Analyzer for the Determination of IR-Absorbing Gases SIL Safety Manual Supplement to instruction manual ULTRAMAT 6 and OXYMAT 6 ULTRAMAT 6F 7MB2111, 7MB2117, 7MB2112, 7MB2118 ULTRAMAT 6E

More information

Reliability of Safety-Critical Systems Chapter 4. Testing and Maintenance

Reliability of Safety-Critical Systems Chapter 4. Testing and Maintenance Reliability of Safety-Critical Systems Chapter 4. Testing and Maintenance Mary Ann Lundteigen and Marvin Rausand mary.a.lundteigen@ntnu.no RAMS Group Department of Production and Quality Engineering NTNU

More information

Rosemount 2130 Level Switch

Rosemount 2130 Level Switch Rosemount 2130 Level Switch Functional Safety Manual Manual Supplement Reference Manual Contents Contents 1Section 1: Introduction 1.1 Scope and purpose of the safety manual.............................................

More information

Jamesbury Pneumatic Rack and Pinion Actuator

Jamesbury Pneumatic Rack and Pinion Actuator Jamesbury Pneumatic Rack and Pinion Actuator Valv-Powr Series VPVL Rev. 3.0 Safety Manual 10SM VPVL en 5/2017 2 Jamesbury Pneumatic Rack and Pinion Actuator, Valv-Powr Series VPVL, Rev 3.0, Safety Manual

More information

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 /

YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 / Smart positioner YT-3300 / 3301 / 3302 / 3303 / 3350 / 3400 / 3410 / 3450 Series SIL Safety Instruction. Supplement to product manual July. 2015 YTC Ver 1.06 1 Table of contents 1 Introduction... 3 1.1

More information

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, MN USA

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, MN USA Failure Modes, Effects and Diagnostic Analysis Project: 3095MV Mass Flow Transmitter Customer: Rosemount Inc. Chanhassen, MN USA Contract No.: Q04/04-09 Report No.: Ros 04/04-09 R001 Version V1, Revision

More information

SPR - Pneumatic Spool Valve

SPR - Pneumatic Spool Valve SIL SM.008 Rev 7 SPR - Pneumatic Spool Valve Compiled By : G. Elliott, Date: 31/08/17 Contents Terminology Definitions:... 3 Acronyms & Abbreviations:... 4 1.0 Introduction... 5 1.1 Purpose & Scope...

More information

Suitable for anyone who is required to maintain industrial pneumatic systems. No prior knowledge of pneumatic or electrical principles is necessary.

Suitable for anyone who is required to maintain industrial pneumatic systems. No prior knowledge of pneumatic or electrical principles is necessary. PNEUMATICS COURSE 660: 4 DAYS: Max 8 Candidates This course provides maintenance personnel and production operators etc with the skills and knowledge necessary to carry out maintenance tasks on pneumatic

More information

Impact of Common Cause Failure on Reliability Performance of Redundant Safety Related Systems Subject to Process Demand

Impact of Common Cause Failure on Reliability Performance of Redundant Safety Related Systems Subject to Process Demand Impact of Common Cause Failure on Reliability Performance of Redundant Safety Related Systems Subject to Process Demand Siamak Alizadeh a, Srinivas Sriramula b School of Engineering, University of Aberdeen,

More information

FP15 Interface Valve. SIL Safety Manual. SIL SM.018 Rev 1. Compiled By : G. Elliott, Date: 30/10/2017. Innovative and Reliable Valve & Pump Solutions

FP15 Interface Valve. SIL Safety Manual. SIL SM.018 Rev 1. Compiled By : G. Elliott, Date: 30/10/2017. Innovative and Reliable Valve & Pump Solutions SIL SM.018 Rev 1 FP15 Interface Valve Compiled By : G. Elliott, Date: 30/10/2017 FP15/L1 FP15/H1 Contents Terminology Definitions......3 Acronyms & Abbreviations...4 1. Introduction...5 1.1 Scope.. 5 1.2

More information

Simulation for verification and validation of functional safety

Simulation for verification and validation of functional safety Lars Mikelsons Zhou Su Bosch Rexroth AG Rexrothstr. 3, 97816 Lohr am Main Abstract Safety of machinery is the most critical issue in the design of mechatronic systems. The verification and validation procedure

More information

High Integrity Pressure Protection Systems HIPPS

High Integrity Pressure Protection Systems HIPPS High Integrity Pressure Protection Systems HIPPS HIPPS > High Integrity Pressure Protection Systems WHAT IS A HIPPS The High Integrity Pressure Protection Systems (HIPPS) is a mechanical and electrical

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

Solenoid Valves For Gas Service FP02G & FP05G

Solenoid Valves For Gas Service FP02G & FP05G SIL Safety Manual SM.0002 Rev 02 Solenoid Valves For Gas Service FP02G & FP05G Compiled By : G. Elliott, Date: 31/10/2017 Reviewed By : Peter Kyrycz Date: 31/10/2017 Contents Terminology Definitions......3

More information

CHANGE HISTORY DISTRIBUTION LIST

CHANGE HISTORY DISTRIBUTION LIST Issue Date of Issue CR/DR Numbers CHANGE HISTORY No. of Pages Draft A Aug 2011 N/A 28 Draft Issue Pages Changed and Reasons for Change Sept 2011 N/A 28 Formal issue with client comments from draft issue

More information

Reliability Analysis Including External Failures for Low Demand Marine Systems

Reliability Analysis Including External Failures for Low Demand Marine Systems Reliability Analysis Including External Failures for Low Demand Marine Systems KIM HyungJu a*, HAUGEN Stein a, and UTNE Ingrid Bouwer b a Department of Production and Quality Engineering NTNU, Trondheim,

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: Emerson s Rosemount 2051 Pressure Transmitter with 4-20mA HART Device Label SW 1.0.0-1.4.x Company: Rosemount Inc. Shakopee, MN USA Contract No.:

More information

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual

EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual SIL Safety Manual DOC.SILM.EEP.EN Rev. 0 April 2017 EL-O-Matic E and P Series Pneumatic Actuator SIL Safety Manual schaal 1:1 EL Matic TM EL-O-Matic E and P Series DOC.SILM.EEP.EN Rev. 0 Table of Contents

More information

Failure Data Analysis for Aircraft Maintenance Planning

Failure Data Analysis for Aircraft Maintenance Planning Failure Data Analysis for Aircraft Maintenance Planning M. Tozan, A. Z. Al-Garni, A. M. Al-Garni, and A. Jamal Aerospace Engineering Department King Fahd University of Petroleum and Minerals Abstract This

More information

Every things under control High-Integrity Pressure Protection System (HIPPS)

Every things under control High-Integrity Pressure Protection System (HIPPS) Every things under control www.adico.co info@adico.co Table Of Contents 1. Introduction... 2 2. Standards... 3 3. HIPPS vs Emergency Shut Down... 4 4. Safety Requirement Specification... 4 5. Device Integrity

More information

Functional Example CD-FE-I-029-V30-EN Safety-related controls SIRIUS Safety Integrated

Functional Example CD-FE-I-029-V30-EN Safety-related controls SIRIUS Safety Integrated Functional Example Safety-related controls SIRIUS Safety Integrated Two safety circuits in a cascade up to SIL 3 acc. to IEC 6206 and PL e acc. to ISO 3849- with ET 200S Safety Motorstarter Solution Local

More information

P33 Safety Exhaust Valve Externally Monitored. Bulletin 0700-B14 ENGINEERING YOUR SUCCESS.

P33 Safety Exhaust Valve Externally Monitored. Bulletin 0700-B14 ENGINEERING YOUR SUCCESS. P Externally Monitored ulletin 07004 ENGINEERING YOUR SUESS. Features Externally Monitored Function When applications demand a safe environment you can count on safety valves from Parker Hannifin. The

More information

Reliability predictions in product development. Proof Engineering Co

Reliability predictions in product development. Proof Engineering Co Reliability predictions in product development Proof Engineering Co Contents Review of reliability theory Ways to predict part reliability Converting parts reliability into a system reliability Ways to

More information

PROCESS AUTOMATION SIL. Manual Safety Integrity Level. Edition 2005 IEC 61508/61511

PROCESS AUTOMATION SIL. Manual Safety Integrity Level. Edition 2005 IEC 61508/61511 PROCESS AUTOMATION Manual Safety Integrity Level SIL Edition 2005 IEC 61508/61511 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of

More information

San Francisco Marriott Marquis Hotel 55 Fourth Street City, State/Country: San Francisco, CA / USA San Francisco, CA / USA Leader(s):

San Francisco Marriott Marquis Hotel 55 Fourth Street City, State/Country: San Francisco, CA / USA San Francisco, CA / USA Leader(s): Background Statement for SEMI Draft Document 5000A DELAYED REVISIONS TO SEMI S2-0310e, ENVIRONMENTAL, HEALTH, AND SAFETY GUIDELINE FOR SEMICONDUCTOR MANUFACTURING EQUIPMENT Addition of Related Information

More information

Competence in Functional Safety

Competence in Functional Safety MANUAL Competence in Functional Safety Safety-instrumented system Instrumentation Automation SMART IN FLOW CONTROL. SAMSON AIR TORQUE CERA SYSTEM KT-ELEKTRONIK LEUSCH PFEIFFER RINGO SAMSOMATIC STARLINE

More information

Determining Occurrence in FMEA Using Hazard Function

Determining Occurrence in FMEA Using Hazard Function Determining Occurrence in FMEA Using Hazard Function Hazem J. Smadi Abstract FMEA has been used for several years and proved its efficiency for system s risk analysis due to failures. Risk priority number

More information

Applicable and have been incorporated into North American Standards.

Applicable and have been incorporated into North American Standards. Applicable and have been incorporated into North American Standards. ANSI B11.0-2010 Safety of Machinery General Requirements and Risk Assessment ANSI B11.TR3-2000 Risk Assessment and Risk Reduction A

More information

Machine Safety Guide 1

Machine Safety Guide 1 1 Machine Safety Guide Contents Introduction...4 Why safety?...6 Legal framework...10 Risk assessment... 16 Safe design and safeguarding...22 Functional Safety... 30 Control system standards including

More information

Simplicity to Control Complexity. Based on Slides by Professor Lui Sha

Simplicity to Control Complexity. Based on Slides by Professor Lui Sha Simplicity to Control Complexity Based on Slides by Professor Lui Sha Reliability Reliability for a giving mission duration t, R(t), is the probability of the system working as specified (i.e., probability

More information

Simple Time-to-Failure Estimation Techniques for Reliability and Maintenance of Equipment

Simple Time-to-Failure Estimation Techniques for Reliability and Maintenance of Equipment F E A T U R E A R T I C L E Simple Time-to-Failure Estimation Techniques for Reliability and Maintenance of Equipment Key Words: Reliability and maintenance, time-to-failure estimation, reactive maintenance

More information

Functional Safety SIL Safety Instrumented Systems in the Process Industry

Functional Safety SIL Safety Instrumented Systems in the Process Industry Products Solutions Services Functional Safety SIL Safety Instrumented Systems in the Process Industry BASF - Press Photo 2 section Foreword rubric 3 Foreword has come into focus since the publication of

More information

E28/Q28 Safety Exhaust Valve Externally Monitored

E28/Q28 Safety Exhaust Valve Externally Monitored E8/Q8 Safety Exhaust Valve Externally Monitored ulletin 9EM4 the total systems approach to air preparation Features Externally Monitored Safety Exhaust Valve Function When applications demand a safe environment

More information

DETERMINATION OF SAFETY REQUIREMENTS FOR SAFETY- RELATED PROTECTION AND CONTROL SYSTEMS - IEC 61508

DETERMINATION OF SAFETY REQUIREMENTS FOR SAFETY- RELATED PROTECTION AND CONTROL SYSTEMS - IEC 61508 DETERMINATION OF SAFETY REQUIREMENTS FOR SAFETY- RELATED PROTECTION AND CONTROL SYSTEMS - IEC 61508 Simon J Brown Technology Division, Health & Safety Executive, Bootle, Merseyside L20 3QZ, UK Crown Copyright

More information

Safe Machinery Handbook

Safe Machinery Handbook Safe Machinery Handbook 2 Contents Introduction...4 Why safety?...6 Legal framework...10 Risk assessment...16 Safe design and safeguarding...22 Functional Safety...30 Control system standards including

More information

A REAL-TIME RISK-INFORMED BOP RETRIEVAL DECISION TOOL

A REAL-TIME RISK-INFORMED BOP RETRIEVAL DECISION TOOL A REAL-TIME RISK-INFORMED BOP RETRIEVAL DECISION TOOL Luiz Fernando Oliveira 1, Joaquim D. Amaral Netto 1, and Gean Rocha 1 1 DNV GL: Rua Sete de Setembro 111,12 andar, Rio de Janeiro, RJ, 20050-006,Brazil

More information

Rosemount 2120 Level Switch

Rosemount 2120 Level Switch Rosemount 2120 Level Switch Functional Safety Manual Manual Supplement Manual Supplement Contents Contents 1Section 1: Introduction 1.1 Scope and purpose of the safety manual.............................................

More information

Integrating Safety and Automation

Integrating Safety and Automation 866-522-2300 / www.asesafety.com Integrating Safety and Automation Presented by: Dennis Aulbrook Safeguarding of Automated Machinery A safeguard is a solution or a combination of solutions that eliminate

More information

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis Failure Modes, Effects and Diagnostic Analysis Project: 3051S SIS Pressure Transmitter, with Safety Feature Board, Software Revision 3.0 Customer: Rosemount Inc. Chanhassen, MN USA Contract No.: Ros 02/11-07

More information