BIMETAL THERMOMETERS BIMETAL THERMOMETERS

Size: px
Start display at page:

Download "BIMETAL THERMOMETERS BIMETAL THERMOMETERS"

Transcription

1 T 20 IMETL THERMOMETER IMETL THERMOMETER Product election Information imetal Thermometers EI eries imetal Thermometers I eries imetal Thermometers EL eries imetal Thermometers ase Dimensions. 207 Options and Thermowells

2 202

3 203 Product election Information imetal Thermometers ase earing Inner Dial Dial Ring Gasket Ring tem haft ushing oil Process onnection External djustment Pinion Gear crews Pointer Window Warning: When selecting all bimetal thermometers, consider the media and the ambient operating conditions. Improper application can be detrimental to the thermometer and can cause failure and possibly personal injury or property damage. Inaccuracies resulting from improper setting of the external adjustment by the user may cause personal injury or property damage. onsult ME 40.3 for guidance in selection and use of bimetal thermometers. Temperature Ranges: tandard Fahrenheit and elsius ranges have been established to encompass all normal temperature measurement requirements. bimetal thermometer can be used at an operating temperature anywhere throughout its dial range. Provision should be made for extreme temperature conditions. No bimetal thermometer should be exposed continuously to process temperatures over 800 F (425 ). Operating onditions: The maximum ambient temperature of the case should be no more than 200 F (95 ); liquid-filled series 50 F (65 ). Temperatures beyond this value may cause discoloration of the dial or result in increased pressure inside the casing which would ultimately lead to failure of the window. The lowest ambient temperature should not exceed 40 F ( 40 ). Thermowells: Thermowells must be used on any application where the stem of the bimetal thermometer may be exposed to pressure, corrosive fluids or high velocity. dditionally, the use of a thermowell permits instrument interchange or calibration check without disturbing or closing down the process. Pointers: The pointers are balanced to close tolerances, and the paint finishes are controlled to assure long-term stability under adverse ultraviolet conditions. ases: There are three case styles. The l series has no adjustment but is hermetically sealed. The hermetic seal prevents entry of moisture into the casing, minimizing the possibility of icing or fogging inside the case. The EL series provides the same features as the El plus the added benefit of liquid filling which prolongs instrument life. Potential wear problems caused by excessive vibration are minimized through dampening, and the liquid medium improves readability. The instruments are leak-tested to ensure the integrity of the joints. ase and stem material is 304 stainless steel. oils: The bimetallic coils are carefully wound and inspected. Each is heat treated for optimum stability and overtemperature capability. earings: The bearings are made of Teflon or other low-friction material. hafts: hafts are made of specially drawn stainless steel wire with a very smooth finish. Dials: The dials are based on computercalculated temperature deflection data and have the Maxivision format to minimize parallax error. Windows: The standard window on EI and I series are heavy-duty glass. Plastic and shatterproof glass are optional. The standard window on EL series is polycarbonate. No other options are available. The complete line of shcroft industrial bimetal thermometers and accessories provides quality choices for your temperature applications. There is a long history of superior quality in engineering, manufacturing and customer service of these products. Each shcroft industrial bimetal thermometer is backed by a limited five year warranty. Each instrument is manufactured to a standard accuracy of % of span (ME 40.3, Grade ) traceable to the National Institute of tandards and Technology (NIT). The bimetal coils are heat treated for stability and overtemperature capability. single helix is used to reduce lag time. The bearings are made of a low-friction long-life material. The shafts are made of specially drawn stainless steel with a very smooth finish. ll joints are welded, and the weld between the stem and the outlet is located at the bottom of the threads to eliminate the possibility of crevice corrosion. ilicone dampening is included for improved vibration resistance. The shcroft Maxivision dial eliminates parallax error by placing the pointer in the same plane as the graduations. The dial can be rotated 360 degrees and can be angled 80 degrees with the Everyangle connection. Everyangle ase onnection: The shcroft Everyangle industrial bimetal thermometer dial face with Maxivision dial can be rotated 360 degrees and angled 80 degrees. It is available in the EI and EL (5 only in EL) series with either a threaded or compression type union connection. This design provides maximum utility. ince the entire case can be rotated and angled, the instrument can be installed almost anywhere and adjusted so that the dial face can be easily read.

4 204 imetal Thermometers eries EI, ME 40.3 Grade (±% of span) Hermetically sealed External adjustment Maxivision dial ±% full-span accuracy (ME 40.3 Grade ) ll-welded stainless steel construction ilicone on the coil provides vibration dampening and superior time response Heavy-duty glass standard; plastic or shatterproof glass optional Limited five-year warranty This series has a hermetic seal and an external adjustment in the rear of the case. s with other shcroft industrial bimetal thermometers, it has a Maxivision dial which eliminates parallax by placing the pointer on the same plane as the graduations. The connection locations are rear, lower, and Everyangle. The hermetic seal prevents entry of moisture into the casing, thus minimizing the possibility of icing or fogging inside the case. The window stays clear, and with the Maxivision dial, precise readings are certain. ELETION TLE ase ize tem tem Lengths vailable Temperature Range Dial ode tyle onnection ode Location ode Length ode F* /Div. Fig. /Div. Fig. ode (inches) Fahrenheit Inter. elsius Inter. Plain 40 Rear R 80/20 50/ Pointed Plain 50 Rear R /20 20/ NPT 60 Rear R /30 0 0/ NPT Union / /00 0 Everyangle E 3 30 EI 2 NPT / / Rear R /300 0/200 2 NPT 60 Lower L / /300 2 NPT Union / /450** 5 50 Everyangle E NPT /700 00/500** 2 NPT 60 Rear R 00/800 Lower L 200/000** 0 00 ** Dual scale ranges available for all standard F ranges (3 and 5 case only) ** atisfactory for continuous service up to 800 F or 425. an be used for intermittent service from 800 to 000 F, or 425 to 500. Use shcroft Duratemp thermometers for ranges above and below those listed above. Minimum stem length for these ranges is 4. Minimum stem length for lower connection and Everyangle is 4. Thermowells must be used on all pressure or velocity applications, to protect the stem of thermometer from corrosion and physical damage, and to facilitate removal of the thermometer without disturbing the process. Maximum ambient temperature is 200 F (95 ). Overtemperature Limits Top of Range F Maximum Overtemperature up to % of span 250/550 50% of span 550/ F ** TO ORDER THI EI ERIE IMETL THERMOMETER: elect: 30 EI 60 R 040 0/250 F XNH. ase ize: 3 ode tyle: ode EI 3. tem onn: 2 NPT ode tem Location: Rear ode R 5. tem Length: 4 ode Range: ode 0/250 F 7. Options: tainless teel Tag (see Page 222) MDE IN U...

5 205 imetal Thermometers eries I, ME 40.3 Grade (±% of span) Hermetically sealed Tamper resistant Maxivision dial ±% full-span accuracy (ME 40.3 Grade ) ll-welded stainless steel construction ilicone on the coil provides vibration dampening and superior time response Heavy-duty glass standard; plastic or shatterproof glass optional Limited five-year warranty This series is tamper proof, hermetically sealed and has the Maxivision dial. The connection locations are rear and lower. The I series of shcroft industrial bimetal thermometers was designed for applications where external adjustment or pointer reset are not desired. The hermetic seal prevents entry of moisture into the casing, thus minimizing the possibility of fogging inside the case. The Maxivision dial provides accurate temperature readings. ELETION TLE ase ize tem tem Lengths vailable Temperature Range Dial ode tyle onnection ode Location ode Length ode F* /Div. Fig. /Div. Fig. ode (inches) Fahrenheit Inter. elsius Inter. Plain 40 Rear R 80/ / Pointed Plain 50 Rear R /20 20/ NPT 60 Rear R /30 0 0/ I 60 2 NPT NPT 60 Rear R / /00 0 Lower L / / /300 0/ Rear R / / / /450** /700 00/500** Lower L 00/ /000** 0 00 ** Dual scale ranges available for all standard F ranges (3 and 5 case only) ** atisfactory for continuous service up to 800 F or 425. an be used for intermittent service from 800 to 000 F, or 425 to 500. Use shcroft Duratemp thermometers for ranges above and below those listed above. Minimum stem length for these ranges is 4. Minimum stem length for lower connection is 4. Thermowells must be used on all pressure or velocity applications, to protect the stem of thermometer from corrosion and physical damage, and to facilitate removal of the thermometer without disturbing the process. Maximum ambient temperature is 200 F (95 ). Overtemperature Limits Maximum Top of Range F Overtemperature up to % of span 250/550 50% of span 550/ F ** TO ORDER THI I ERIE IMETL THERMOMETER: elect: 30 I 60 R 040 0/250 F XNH. ase ize: 3 ode tyle: ode I 3. tem onn: 2 NPT ode tem Location: Rear ode R 5. tem Length: 4 ode Range: ode 0/250 F 7. Options: tainless teel Tag (see Page 222) MDE IN U...

6 206 imetal Thermometer eries EL, ME 40.3 Grade (±% of span) ilicone liquid filled External adjustment Durable polycarbonate window Maxivision dial ±% full-span accuracy (ME 40.3 Grade ) ll-welded stainless steel construction Limited five-year warranty This series liquid filled is available in 3 rear, 5 rear and 5 Everyangle connections. The external adjustment is standard. The shcroft liquid-filled thermometer provides the same features as the EI style with the added benefit of liquid filling. The potential wear problem caused by excessive vibration is minimized through dampening and the instrument life is prolonged. The liquid medium also improves readability. ELETION TLE ase ize tem tem Lengths vailable Dial ode tyle onnection ode Location ode Length ode (inches) ode Temperature Range F* /Div. Fig. /Div. Fig. Fahrenheit Inter. elsius Inter NPT 60 Rear R / / / / /30 0 EL 2 NPT / /50 5 Union Everyangle E / / / / NPT 2 NPT / / Rear R * Dual scale ranges available for all standard F ranges. Minimum stem length for Everyangle connection is 4. Use shcroft Duratemp thermometers for ranges above and below those listed above. Thermowells must be used on all pressure or velocity applications, to protect the stem of thermometer from corrosion and physical damage, and to facilitate removal of the thermometer without disturbing the process. Maximum ambient temperature is 50 F (65 ). Overtemperature Limits Maximum Top of Range F Overtemperature up to 60 00% of span 60/ F 300/ F TO ORDER THI EL ERIE IMETL THERMOMETER: elect: 30 EL 60 R 040 0/250 F XNH. ase ize: 3 ode tyle: ode EL 3. tem onn: 2 NPT ode tem Location: Rear ode R 5. tem Length: 4 ode Range: ode 0/250 F 7. Options: tainless teel Tag (see Page 222) MDE IN U...

7 207 ase Dimensions G 30EI60R 30EL60R 50EI60R 50EL60R G 30I60R 50I60R 20EI40R 20EI50R 20I40R 20I50R 30EI60L 50EI60L D E H H D 30EI42E 50EI42E 50EL42E.00" 30EI60E 50EI60E 50EL60E 20EI60R 20I60R 30I60L 50I60L E ase Dial onnection eries ize Location Weight in ounces ase eries D E G H NPT Hex I EI EL I, EI 2 Rear (Plain) (53) (0) (8) I, EI 2 Rear (Plain, pointed stem) (53) (0) (8) I, EI 2 Rear (Threaded) (53) (0) (8) I, EI, EL 3 Rear (80) (5) (8) I, EI 3 Lower (80) (47) (67) (6) EI 3 Everyangle (80) (5) (42) (87) I, EI, EL 5 Rear (28) (8) (8) I, EI 5 Lower (28) (49) (92) (6) EI, EL 5 Everyangle (28) (8) (48) (9) NOTE Figures in parenthesis ( ) are in millimeters. ll other dimensions are in inches. 2 tandard dimensions are 2 2, 4, 6, 9, 2, 5, 8 and 24 inches. tandard stem diameter is 4 inch. 3 dd oz. for every 2 inches of stem length.

8 208

9 209 DURTEMP THERMOMETER REMOTE REDING THERMOMETER Product election Information... 2 Duratemp Thermometer, Remote Mount, eries Duratemp Thermometer, Remote Mount, eries Duratemp Thermometer, Remote Mount, eries Duratemp Thermometer, Remote Mount, eries Duratemp Thermometer, Remote Mount, 600H-45 eries DIRET REDING THERMOMETER Duratemp Thermometer, Direct Mount, 600 eries Duratemp Thermometer, ase, ulb and rmor Dimensions ase Dimensions Thermowells imetal and Duratemp Thermometer Options Type 2400E and 240E Digital Thermometers ccessories

10 20

11 2 Product election Information Duratemp Remote-Mount Thermometers Plastic Mounting Frame Dial Indicator Ring Gasket nap Ring Phenolic ase Pointer rmor crews Window ulb The superiority of a Duratemp thermometer is revealed by comparison to conventional thermometry. onventional gas thermometers operate on the principle that the absolute pressure is proportional to the absolute temperature. To obtain a usable temperature span, elevated working pressures must be used which frequently produce high stresses in the ourdon tube. These high stresses reduce instrument life and may be hazardous. The Duratemp thermometer on the other hand utilizes a combination of inert gas and activated carbon called a molecular sieve. This combination produces much lower internal pressures than conventional thermometers for the same temperature span. These lower pressures are transmitted to a compact helical ourdon tube. The ourdon tube connects directly to the pointer shaft thus eliminating the traditional movement assembly. With this advantage the Duratemp thermometer is able to provide long life and sustained accuracy under the most adverse shock and vibration conditions. ccuracy: ±% of range span. ulb ize: 3 long by 3 8 O.D. bulb. ulb Material: 36 mbient Error: mbient error is a function of line length, ambient temperature and other system parameters. The error at mid-scale will be ± 2% of range span for a ±25 F change in ambient temperature, for a typical thermometer. onsult factory for details. Vibration and hock Resistance: Extreme resistance similar to that required by MIL-T ctuation: Gas/activated carbon. Pointer driven directly by lightweight helical ourdon tube which is silicone damped. Field Zero djustment: djustable pointer. Over-range: Minimum 25% of span beyond top of range. If greater over-range is anticipated, consult ustomer ervice. Head Error: None. No correction required for any mounting configuration. apillary Material: 300 series stainless steel. Line Length: 5-80 ft in standard increments. rmor: II 302 pring rmor as standard. Dial izes: Maxivision anti-parallax two piece dial design 4 2 and 6 sizes elcius or Fahrenheit. ingle plane design for all dual scales and 8 2 size. Ranges: tandard Fahrenheit ranges available from 320 F to 200 F. elsius and dual scale also available. ases: 5 basic cases with lower or back connections, surface or flush mounted in stainless steel, phenolic or aluminum. ll remote mount cases are field interchangeable, within the same range. Direct mount units available 4 2 stainless steel case only. (Everyangle) Direct Mount tem Lengths: Four standard increment of semi-rigid stainless steel from 6 inches to 5 inches. (onsult factory for longer stem lengths.) Direct Mount Union: 2 NPT union connection fixed at the top of the stem. Operating onditions: The maximum case temperature should not exceed 60 F (7 ). The line should be laid so that it will not be exposed to extreme temperatures such as nearby steam pipes, ovens or other heated surfaces. Thermowells: Thermowells must be used on any application where the bulb of the thermometer may be exposed to pressure, corrosive fluids or high velocity. dditionally, the use of a thermowell permits instrument interchangeability or recalibration without shutting down the process. Dials: luminum dials have highly legible black markings on a white background. The Maxivision dial is a linear anti-parallax dial for excellent readability in the 4 2 and 6 sizes. The divisions and the pointer are in the same plane which allows readability from any angle without parallax error. Windows: The standard window for the Duratemp thermometer is glass. hatterproof glass and plastic disc windows are optional. MERURY FREE Gas Filled: NIOH and OH compliance for mercury contamination hazards. Protects personnel and processes from accidental contamination. No Head or Elevation Error: Gear and pinion movements are eliminated, resulting in increased instrument life and reduced replacement costs. ilicone damped ourdon tube eliminates damage from shock and vibration.

12 22 Duratemp Thermometer eries ccuracy (±% F..) Exclusive movementless design resists shock and vibration no gears to wear or misalign resulting in increased instrument life Gas-operated molecular sieve No elevation error Mercury free One bulb size for all ranges ±% full-span accuracy Maxivision dial Limited five-year warranty high impact-resistant polished stainless steel case. ayonet ring facilitates easy removal for glass replacement and pointer adjustment. versatile case that enables surface or flush mounting. vailable in 4 2 dial size. ELETION TLE L07 K Table Table 2 Table 3 Table 4 Table 5 Table 6 E TYLE E IZE MOUNTING UL TYLE* RMOR TYLE LINE LENGTH RNGE ODE DERIPTION ODE IZE MOUNTING ONNETION ODE DERIPTION ODE DERIPTION ODE LINE LENGTH ODE INGLE RNGE URFE FLUH LOWER RER 320/200 F 0 T. T. 0 4 /2 2 endable 0 YONET E 00/00 F RING 4 /2 with L0 5 2 NPT union G 40/80 F connection tainless K 20/240 F teel L 50/300 F 03 Plain bulb with rigid pring N 50/550 F, R 50/750 F no union L03 0 T 400/200 F Y 200/00 08 Plain bulb with rigid, L 80/40 2 NPT union on N 40/80 armor L /20 T 0/ endable U 0/300 with 2 NPT union W 0/400 connection L09 30 J 200/650 DUL RNGE 8 24 endable 20/240 F E with 2 NPT union 0/20 connection L /550 F F 0/300 *Minimum recommended insertion length 50/300 F DR ( u dimension) in liquids 0/50 L9 80 is 4 inches and in gases 40/80 F is 6 inches for standard DT 40/80 3 /8 x 3 bulb 600 TO ORDER THI DURTEMP THERMOMETER: elect: L07 K XNH. ase tyle: tainless teel/ayonet Ring Table 2. ase ize & Mounting: 4 2 urface, Lower Table 2 3. ulb tyle: 2 endable Extension with Union onnection Table 3 4. rmor tyle: tainless teel pring Table 4 5. Line Length: 20 feet Table 5 6. Temperature Range: 20/240 F Table 6 7. Options: tainless teel Tag (ee Page 222) MDE IN U...

13 23 Duratemp Thermometer eries ccuracy (±% F..) Exclusive movementless design resists shock and vibration no gears to wear or misalign resulting in increased instrument life Gas-operated molecular sieve No elevation error Mercury free One bulb size for all ranges ±% full-span accuracy Maxivision dial Limited five-year warranty n aluminum case with a durable epoxy finish. Designed specifically for panel mounting. hinged ring permits glass replacement and pointer adjustment. vailable in 4 2, 6 and 8 2 sizes. ELETION TLE L07 K Table Table 2 Table 3 Table 4 Table 5 Table 6 E TYLE E IZE MOUNTING UL TYLE* RMOR TYLE LINE LENGTH RNGE ODE DERIPTION ODE IZE MOUNTING ONNETION ODE DERIPTION ODE DERIPTION ODE LINE LENGTH ODE INGLE RNGE URFE FLUH LOWER RER 320/200 F /2 2 endable LUMINUM 0 E 00/00 F HINGED 27 6 /2 with L0 5 2 RING NPT union G 40/80 F 35 8 /2 connection tainless K 20/240 F teel L 50/300 F 03 Plain bulb with rigid pring N 50/550 F, R 50/750 F no union L03 0 T 400/200 F Y 200/00 08 Plain bulb with rigid, L 80/40 2 NPT union on N 40/80 armor L /20 T 0/ endable U 0/300 with 2 NPT union W 0/400 connection L09 30 J 200/650 DUL RNGE 8 24 endable 20/240 F E with 2 NPT union 0/20 connection L /550 F F 0/300 *Minimum recommended insertion length 50/300 F DR ( u dimension) in liquids 0/50 L9 80 is 4 inches and in gases 40/80 F is 6 inches for standard DT 40/80 3 /8 x 3 bulb 600 TO ORDER THI DURTEMP THERMOMETER: elect: L07 K XNH. ase tyle: luminum/hinged Ring Table 2. ase ize & Mounting: 4 2 Flush, Rear Table 2 3. ulb tyle: 2 endable Extension with Union onnection Table 3 4. rmor tyle: tainless teel pring Table 4 5. Line Length: 20 feet Table 5 6. Temperature Range: 20/240 F Table 6 7. Options: tainless teel Tag (ee Page 222) MDE IN U...

14 24 Duratemp Thermometer eries ccuracy (±% F..) Exclusive movementless design resists shock and vibration no gears to wear or misalign resulting in increased instrument life Gas-operated molecular sieve No elevation error Mercury free One bulb size for all ranges ±% full-span accuracy Maxivision dial Limited five-year warranty black-coated aluminum case with excellent impact resistance. Threaded ring permits adjustment. vailable in 4 2 and 6 sizes. ELETION TLE L07 K Table Table 2 Table 3 Table 4 Table 5 Table 6 E TYLE E IZE MOUNTING UL TYLE* RMOR TYLE LINE LENGTH RNGE ODE DERIPTION ODE IZE MOUNTING ONNETION ODE DERIPTION ODE DERIPTION ODE LINE LENGTH ODE INGLE RNGE URFE FLUH LOWER RER 320/200 F /2 2 endable LUMINUM 0 E 00/00 F THREDED 5 6 /2 with L0 5 2 NPT union G 40/80 F RING connection tainless K 20/240 F teel L 50/300 F 03 Plain bulb with rigid pring N 50/550 F, R 50/750 F no union L03 0 T 400/200 F Y 200/00 08 Plain bulb with rigid, L 80/40 2 NPT union on N 40/80 armor L /20 T 0/ endable U 0/300 with 2 NPT union W 0/400 connection L09 30 J 200/650 DUL RNGE 8 24 endable 20/240 F E with 2 NPT union 0/20 connection L /550 F F 0/300 *Minimum recommended insertion length 50/300 F DR ( u dimension) in liquids 0/50 L9 80 is 4 inches and in gases 40/80 F is 6 inches for standard DT 40/80 3 /8 x 3 bulb 600 TO ORDER THI DURTEMP THERMOMETER: elect: L07 K XNH. ase tyle: luminum/threaded Ring Table 2. ase ize & Mounting: 4 2 urface, Lower Table 2 3. ulb tyle: 2 endable Extension with Union onnection Table 3 4. rmor tyle: tainless teel pring Table 4 5. Line Length: 20 feet Table 5 6. Temperature Range: 20/240 F Table 6 7. Options: tainless teel Tag (ee Page 222) MDE IN U...

15 25 Duratemp Thermometer eries ccuracy (±% F..) Exclusive movementless design resists shock and vibration no gears to wear or misalign resulting in increased instrument life Gas-operated molecular sieve No elevation error Mercury free One bulb size for all ranges ±% full-span accuracy Maxivision dial Limited five-year warranty The phenolic case construction is ideal for most ambient conditions. Flush or surface mounting. nap ring permits pointer adjustment. vailable in 4 2 and 6 sizes. ELETION TLE L07 K Table Table 2 Table 3 Table 4 Table 5 Table 6 E TYLE E IZE MOUNTING UL TYLE* RMOR TYLE LINE LENGTH RNGE ODE DERIPTION ODE IZE MOUNTING ONNETION ODE DERIPTION ODE DERIPTION ODE LINE LENGTH ODE INGLE RNGE URFE FLUH LOWER RER 320/200 F /2 2 endable PHENOLI 0 E 00/00 F NP 08 4 /2 with L0 5 2 RING NPT union G 40/80 F 38 4 /2 connection tainless K 20/240 F 6 6 /2 teel L 50/300 F 03 Plain bulb with rigid pring N 50/550 F, R 50/750 F no union L03 0 T 400/200 F Y 200/00 08 Plain bulb with rigid, L 80/40 2 NPT union on N 40/80 armor L /20 T 0/ endable U 0/300 with 2 NPT union W 0/400 connection L09 30 J 200/650 DUL RNGE 8 24 endable 20/240 F E with 2 NPT union 0/20 connection L /550 F F 0/300 *Minimum recommended insertion length 50/300 F DR ( u dimension) in liquids 0/50 L9 80 is 4 inches and in gases 40/80 F is 6 inches for standard DT 40/80 3 /8 x 3 bulb 600 TO ORDER THI DURTEMP THERMOMETER: elect: L07 K XNH. ase tyle: Phenolic nap Ring Table 2. ase ize & Mounting: 4 2 urface, Lower Table 2 3. ulb tyle: 2 endable Extension with Union onnection Table 3 4. rmor tyle: tainless teel pring Table 4 5. Line Length: 20 feet Table 5 6. Temperature Range: 20/240 F Table 6 7. Options: tainless teel Tag (ee Page 222) MDE IN U...

16 26 Duratemp Thermometer eries 600H-45 ccuracy (±% F..) Exclusive movementless design resists shock and vibration no gears to wear or misalign resulting in increased instrument life Gas-operated molecular sieve No elevation error Mercury free One bulb size for all ranges ±% full-span accuracy Maxivision dial Limited five-year warranty This hermetically sealed case is designed for applications where extreme moisture or dust is present. vailable in a 4 2 solid front phenolic turret case, lower connection. ELETION TLE 600H L07 K Table Table 2 Table 3 Table 4 Table 5 Table 6 E TYLE E IZE MOUNTING UL TYLE* RMOR TYLE LINE LENGTH RNGE ODE DERIPTION ODE IZE MOUNTING ONNETION ODE DERIPTION ODE DERIPTION ODE LINE LENGTH ODE INGLE RNGE URFE FLUH LOWER RER 320/200 F 45 PHENOLI 2 endable 0 HERMETILLY 60 4 /2 E 00/00 F L0 5 ELED with 2 NPT union G 40/80 F connection tainless K 20/240 F teel L 50/300 F 03 Plain bulb with rigid pring N 50/550 F, R 50/750 F no union L03 0 T 400/200 F Y 200/00 08 Plain bulb with rigid, L 80/40 2 NPT union on N 40/80 armor L /20 T 0/ endable U 0/300 with 2 NPT union W 0/400 connection L09 30 J 200/650 DUL RNGE 8 24 endable 20/240 F E with 2 NPT union 0/20 connection L /550 F F 0/300 *Minimum recommended 50/300 F insertion length DR ( u dimension) in liquids 0/50 L9 80 is 4 inches and in gases 40/80 F is 6 inches for standard DT 40/80 3 /8 x 3 bulb 600H TO ORDER THI DURTEMP 600H-45 THERMOMETER: elect: 600H L07 K XNH. ase tyle: Phenolic Hermetically ealed Table 2. ase ize & Mounting: 4 2 urface, Lower Table 2 3. ulb tyle: 2 endable Extension with Union onnection Table 3 4. rmor tyle: tainless teel pring Table 4 5. Line Length: 20 feet Table 5 6. Temperature Range: 20/240 F Table 6 7. Options: tainless teel Tag (ee Page 222) MDE IN U...

17 27 Duratemp Thermometer Direct-Mounted eries 600 ccuracy (% F..) Exclusive movementless design resists shock and vibration no gears to wear out or misalign resulting in increased instrument life Gas-operated molecular sieve Mercury free % full-span accuracy Everyangle Duratemp thermometer can be rotated 360 and can be angled 80, ensuring readability in any installation Maxivision dial Limited five-year warranty The direct-reading thermometer (stainless steel case only) offers the same unique features of the shcroft Duratemp remote-reading thermometer for those critical applications where only a direct-connected instrument can be used. vailable in 4 2 dial size. The Everyangle Duratemp thermometer may be rotated 360 for readability and the stem turned 80 for the most challenging installations. ELETION TLE Type Table Table ODE TEM LENGTH ODE INGLE RNGE ODE DUL RNGE D I R E T - M O U N T E D 0 emirigid tainless teel 6 02 emirigid tainless teel 9 03 emirigid tainless teel 2 04 emirigid tainless teel 5 05 emirigid tainless teel 8 06 emirigid tainless teel emirigid tainless teel emirigid tainless teel 36 E G K L N R T Y L N T U W J 320/200 F 00/00 F 40/80 F 20/240 F 50/300 F 50/550 F 50/750 F* 400/200 F* 200/00 80/40 40/80 0/20 0/50 0/300 0/400 * 200/650 * E F DR DT 20/240 F 0/20 50/550 F 0/300 50/300 F 0/50 40/80 F 40/80 * For these ranges a minimum dimension (stem length) of 9 inches is required. This removes case from exposure to high temperature which may damage the instrument. NOTE: Thermowells must be used whenever an shcroft Duratemp thermometer is installed on a pressurized application or where fluid velocity or corrosive media is present. TO ORDER THI 600 DURTEMP THERMOMETER: ELET XNH. tem Length: Length: 6 Table 2. Temperature Range: 320/200 F Table 2 3. Options: tainless teel Tag (ee Page 222) MDE IN U...

18 28 ulb and rmor Dimensions tyle 0, 7 and 8 endable Extension, Union onnection tyle 03 Plain tyle 08 Long Extension, Locking Fitting 7/6 Hex () djustable Union onnector 5/8 Wrench Flats (6) /2 NPT 5/6 (24) learance Hole 3-/4 (336) djustable Union onnection on rmor 3/6 Hex (2) 7/8 Hex (22) /2 NPT -/6 (27) Dia. learance Hole 3/6 (4,7) Dia. endable Extension Min. 7-/4 (84) Max. Line Length 3/8 (0) Dia. ensitive Portion 7-/4 (84) ulb ulb ode ize Max. Min (76) (305) (38) (02) (76) (457) (533) (02) (76) (60) (686) (02) 3/8 Dia. (0) 3 (66) ensitive Portion 3/8 Dia. (0) 3 (76) ensitive Portion 600 Everyangle D FOR TEMPERTURE ELOW 750 F U-Dimension (Insertion Length) (52) (4) FOR TEMPERTURE 750 F ND OVE UE WELL WITH 3 LG U-Dimension Well Lag (Insertion Length) (229) (4) E (229) (9) (305) (9) (305) (268) (38) (268) F G 7 /8 Hex (22) /2 NPT Dial ize D E F G H Inches (20) (52) (28) (8) (22) (76) (25) (0) H NOTE: Dimensions in inches, ( ) are miliimeters.

19 29 ase Dimensions tainless teel ase FLUH PNEL MOUNTING URFE MOUNTING HH FF EE V DD F M Dia. hole in panel 2-E Dia. Holes HH JJ D J U Dial ize D E F J M U DD FF EE HH JJ Inches # (20) (56) (30) (27) (6) (4) (2) (2) () (37) (67) (25) (57) (4) (76) (89) NOTE: Dimensions in inches, ( ) are miliimeters Hinged Ring ase FLUH PNEL MOUNTING U Nuts & washers not supplied by shcroft FLUH PNEL MOUNTING Nuts & washers not supplied by shcroft F M Dia. hole in panel F M Hole in panel 3 Mounting studs threaded equally spaced on E dia... K LL 3 Mounting studs threaded equally spaced on E dia and 6 ack onnection 8 2 ack onnection ase ize E F K M U LL Inches K LL (20.7) (56) (53) (37) (4) (27) (24) (6) (9) (3) (3) (23.7) (57) (90.5) (78) (54) (27) (65) (6) (9) (3) (3) (20.7) (57) (253) (244) (54) (27) (229) (6) (9) (3) (3) NOTE: Dimensions in inches, ( ) are miliimeters.

20 220 ase Dimensions luminum-threaded Ring ase J V F 3-L dia. holes on E dia... ase ize D E F J L V Inches (48) (57) (26) (24) (37) (4) (0) (5,5) (60) (94) (57) (65) (24) (78) (54) () (7) (79) , 600H-45 Phenolic ase D PPROXIMTE WEIGHT (L.) FOR LL REMOTE REDING DURTEMP THERMOMETER Line ase ize Length URFE MOUNTING FLUH MOUNTING J Mounting hardware supplied by shcroft M Hole in panel V F 3-L dia. holes on E dia... D LL ase Model ize D E F J L V M LL PP Inches (48) (59) (29) (25) (37) (4) (4) (5,5) (5) (67) (54) (48) (2)-(3) (94) (60) (68) (27) (78) (54) (6) (7) (5) (89) (97) (85) (2)-(3) #0-24 x 7 8 # 4-20 x H (48) (86) (29) (4) (37) (25) (5,5) (5) (67) (54) (48) (2)-(3) #0-24 x 7 8 NOTE: Dimensions in inches, ( ) are miliimeters.

21 22 Thermowells 75 W 0750 H T 260 ize U-Dimesion Thread Lagging hank Type ore Material ap & Facing Rating pecial hain Lagging Length ode Inches ode Inches ode Inches ode Type ode Type ode Rating # Without T NPT Thd. rass L With W Weld-in arbon teel F Flanged II V M Van tone ocket Weld Limited pace Threaded II G Ground Joint anitary ode Internal Thread 2 NPM ode H R hank Tapered traight tepped uilt-up ode Diameter ode Material rass 2 tainless teel ode Facing F Flat Face R Raised Face J Ring Joint L Lap Joint Type: traight (Uniform) hank, Threaded ore ize:.385 Process onn.: 2, 3 4, NPT, Wed-In Materials: rass, arbon teel 304 tainless teel, 36 tainless teel Type: tepped hank, Threaded ore ize:.260 Process onn.: 2, 3 4, NPT Materials: rass, arbon teel 304 tainless teel, 36 tainless teel Type: Tapered hank, Threaded ore ize:.260,.385 Process onn.: 2, 3 4, NPT Materials: rass, arbon teel 304 tainless teel, 36 tainless teel Type: ocket Weld ore ize:.260,.385 Process onn.: 3 4, Pipe ize Materials: 304 tainless teel, 36 tainless teel, arbon teel Type: Van tone ore ize:.260,.385 Process onn.:, 2 Pipe ize Materials: 304 tainless teel, 36 tainless teel Type: Weld-in ore ize:.260,.385 Process onn.: 2 Dia. Materials: 304 tainless teel, 36 tainless teel Type: Flanged ore ize: 260,.385 Process onn.:, 2, 2 Pipe ize Materials: 304 tainless teel, 36 tainless teel Type: anitary ore ize:.260,.385 Process onn.: Tri-lamp connection, 2, 2 Materials: 304 tainless teel, 36 tainless teel MDE IN U... tandard onfiguration tandard onfiguration tandard onfiguration tandard onfiguration tandard onfiguration tandard onfiguration tandard onfiguration tandard onfiguration Lagging onfiguration Lagging onfiguration Lagging onfiguration Lagging onfiguration Lagging onfiguration

22 222 imetal Thermometer and Duratemp Thermometer Options DURTEMP ND IMETL OPTION ode Description imetal Duratemp X Dual scale XDM Dial marking XED 2 High and low electric contacts XEE 2 Double high-electric contacts XEF 2 Double low-electric contacts XEG 2 Electric contacts off at low or high and on in-between XEO Externally adjustable red set hand XEP Externally adjustable maximum pointer XEQ Externally adjustable minimum pointer XNG Nonglare XNN Paper tag XNH tainless steel tag XPD 3 Plastic window XG 3 hatterproof glass XH tationary red set hand XTK Tank car thermometer X stem diameter with 2 NPT X NPT when 2 NPT is standard. 3 and 5 case only /2 and , and styles only. 3. Not available on EL liquid filled thermometers. Polycarbonate is the standard window on EL series. 4. Not available on 2 case. 5. Only available on rear connect.

23 223 Digital Thermometer Type 2400E and 240E ccuracy (±2 NF per -2) Watertight ultrasonic-sealed case olid state design LED display with 2 high numerals Reverse-polarity protection Detachable sensors Retrofits 2 and 2 2 vapor thermometers ccessible zero and span adjustment NF approval UL-recognized power supply ccuracy ±2 F per NF -2 The shcroft 2400E and 240E digital thermometers are compact, solid state temperature measurement and display devices. The 2400E measures temperature with a lasertrimmed 2000 ohm RTD contained in a stainless steel probe. The signal from the RTD is conditioned and sent through an analog-to-digital converter and is shown on a LED display. The unit is powered by 6 Vdc, which is delivered through a power supply that operates on 0 Vac (220 Vac and 24 Vac are optional). When more than one indicator is required, two thermometers can be operated by one 0 Vac supply. The power supply is UL recognized and the complete unit is NF approved for class -2 applications. ELETION TLE 2400 E /99 F XJ8 Table Table 2 Table 3 Table 4 Table 5 Table 6 Model Display Power upply () Line Length (3) Options ode Desc. ode Desc. ode Desc. ode Desc. Range ode ode Desc Panel mount E LED 0 Vac feet 40/99 F XJ7 (2) 2 2 mounting plate 220 Vac XXX pecial 0/250 F Panel mount 24 Vac Length (4) 40/20 XJ8 (2) 2 mounting plate w/u clamp () If power supply is not required change model number 2400 to 240 or 240 to 24. (2) Not available on 240 case. (3) tainless steel probe dimension, dia. x 2.54 long. (4) Maximum line length is 30 feet. To Order THI TYPE 2400E/240E DIGITL THERMOMETER: elect: 2400 E /99 F XJ8. Type: Display w/power pack Table 2. Display: LED Table 2 3. Power: 0 Vac Table 3 4. Line Length: 8 Table 4 5. Temperature Range: 40/99 F Table 5 6. Option: 2 Mounting Plate Table 6

24 224 ccessories UL ND RMOR TYLED REMOTE MOUNTED tyles 0, 7 and 8 are bendable s with union connections. 0 (2 bendable ) is the standard Duratemp bulb style and is suitable for a variety of insertion lengths and lagging requirements. 7 is a 8 bendable, 8 is a 24 bendable. The union connection on all three styles is pressure tight and can be freely moved the entire length of the bendable portion. fter installation, the bendable may be formed to suit the application. tyle 03 3 plain bulb for applications used in open tanks where pressures and velocities are negligible. tyle 08 The compression fitting fastens anywhere along the armored line. This bulb style is well suited for insertion requirements in excess of 3 2. The 08 style is not a pressure tight connection. thermowell is recommended for this style and for all bulb styles. RMOR TYLE tyle II 302 stainless steel spring armor is supplied as standard. Originally designed for U.. Navy Hi hock thermometers. TNK R THERMOMETER ode XTK shcroft s Duratemp movementless design is well suited for severe vibration and shock applications as seen in railroad tank cars or other rolling stock apllications, such as milk, chemical and produce transportation. The option XTK is available in a 8 2 case with a large adjustable pointer and a maximum indicating pointer. The range available is 20/240 F and the dial is marked Tank ar Thermometer. The maximum indicating pointer illustrates the highest temperature sensed by the thermometer. ase size and pointer size makes the Duratemp easily read from a distance.

Quick Guide Temperature Instruments

Quick Guide Temperature Instruments 45 Quick Guide Temperature Instruments EI, I & EL INDUTRIL 600 & 600 DURTEMP 2400E & 240E DIGITL IMETL THERMOMETER THERMOMETER THERMOMETER URY ME 40.3 Grade (±% of span) DIL IZE EI, I 2, 3, 5 (EL 3, 5

More information

Test Gauges. A Halliburton Company BULLETIN TG-2

Test Gauges. A Halliburton Company BULLETIN TG-2 est auges Halliburton ompany ULLEIN -2 Features & enefits shcroft est auges 2 resser engineers have developed a new generation of test gauges to meet the exacting needs of instrument engineers and quality

More information

McDaniel. General Service Gauges. (Brass Internals) Stainless Steel Case 1 1 /2 and 2 1 /2 Gauges. All Brass 2 and 2 1 /2 Gauges M C

McDaniel. General Service Gauges. (Brass Internals) Stainless Steel Case 1 1 /2 and 2 1 /2 Gauges. All Brass 2 and 2 1 /2 Gauges M C cdaniel General Service Gauges (Brass Internals) Polyamid B ase (Fiberglass reinforced) 4 and 6 Gauges Stainless Steel ase 1 1 /2 and 2 1 /2 Gauges All Brass 2 and 2 1 /2 Gauges cdaniel General Service

More information

GILMONT ACCUCAL FLOWMETERS

GILMONT ACCUCAL FLOWMETERS OPERATING MANUAL GILMONT ACCUCAL FLOWMETERS 28W092 Commercial Ave. Barrington, IL U.S.A. 60010-2392 (847) 381-4888 (847) 381-7053 (Fax) 800-962-7142 www.barnant.com e-mail: barnant@barnant.com A-1299-0766

More information

How to specify a product. Process Sensors and Mechanical Instruments

How to specify a product. Process Sensors and Mechanical Instruments How to specify a product Process Sensors and Mechanical Instruments Keep the overview. Here is some guideline information on how to specify our products. Intended as supplementary help to specification

More information

PRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a

PRESSURE & TEMPERATURE GAUGES PRESSURE TEMPERATURE. Catalogue H20200a PRESSURE & TEMPERATURE GAUGES PRESSURE Catalogue TEMPERATURE Applications The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies.

More information

DTG - LCD Digital Temperature Gauge USER MANUAL

DTG - LCD Digital Temperature Gauge USER MANUAL DTG - LCD USER MANUAL Page 1 of 7 USERS GUIDE page 1. Description 3 2. Function 3 3. Safety Instruction 3 3.1. Safety Conventions 3 3.2. Proper Use 3 4. Installation 4 4.1. Unpacking 4 4.2. Storage 4 4.3.

More information

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION AND OPERATING INSTRUCTIONS For 3D Instruments Direct Drive Pressure Gauges 3D Instruments Inc., 15542 Chemical Lane, Huntington Beach, CA, 92649, U.S.A. Tel. (714) 894-5351, Fax. (714) 895-4309

More information

Buying more than 11 gauges? Call Lesman for additional discounts.

Buying more than 11 gauges? Call Lesman for additional discounts. Low Cost Liquid Filled Pressure Gauges Size: 1.5", 2", and 2.5" Accuracy: 2.5% of full scale Materials: Case and ring: 304 stainless steel; Window: Polycarbonate; Seals: Buna-N; Pointer: Black-finished

More information

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1. Thin pressure gauge G401-W Series Thin, compact design ideal for incorporating devices. Suitable for filter regulator, regulator, and pressure switch (P4000-W). onnection: O ring seal, set screw G401-W

More information

Expansion Thermometers Stainless Steel Series, Model 70

Expansion Thermometers Stainless Steel Series, Model 70 Mechanical Temperature Measurement Expansion Thermometers Stainless Steel Series, Model 70 WIKA Data Sheet TM 81.01 Applications General-purpose temperature measuring instruments for gaseous, liquid and

More information

Accu-Drive Pressure Gauges

Accu-Drive Pressure Gauges Accu-Drive Gauges DIRECT DRIVE TECHNOLOGY Direct Drive Concept At 3D Instruments, we believe that simple is beautiful!! Replacing the antiquated C-shaped bourdon tube in our Accu-Drive gauges is a unique

More information

INDUSTRIAL THERMOMETER

INDUSTRIAL THERMOMETER TMT703 INDUSTRIAL THERMOMETER The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the

More information

Related products. Components for air preparation and pressure adjustment / F.R.L. unit. Pressure gauge. Indidcator

Related products. Components for air preparation and pressure adjustment / F.R.L. unit. Pressure gauge. Indidcator Related products Pressure gauge / indicator omponents preparation and pressure adjustment / unit Refrigerating ir uto. drain ir Pressure gauge ONTENTS Pressure gauge assembly (G401-W) 660 With safety mark

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

AISI 304 SS (Rolling Type), Bayonet type for NS 80 mm Copper Alloy Copper Alloy Copper Alloy Alloy Brazing / Soldering

AISI 304 SS (Rolling Type), Bayonet type for NS 80 mm Copper Alloy Copper Alloy Copper Alloy Alloy Brazing / Soldering aumer T Case rass Pressure Gauge ourdon type pecial Features tainless steel case Rugged construction Dry or liquid filled tandard followed in general N 837-1 pplication Oil Water Pneumatics Hydraulics

More information

Oxidation Stability of Gasoline and Aviation Fuels

Oxidation Stability of Gasoline and Aviation Fuels Oxidation Stability of Gasoline (Induction Period Method) Oxidation Stability of Aviation Fuels (Potential Residue Method) Test Method Provides an indication of the tendency of gasoline and aviation fuels

More information

IFP C175-* REMOTE CONTROL RELIEF VALVE

IFP C175-* REMOTE CONTROL RELIEF VALVE IFP C175-* REMOTE CONTROL RELIEF VLVE Low Pressure Differential Quiet Operation Easy to djust Handle Three Pressure Ranges vailable Panel Mount Design P T Model Pressure Range (PSI) Rated Flow (US GPM)

More information

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment)

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment) 3820050/4 IM-P382-01 CH Issue 4 SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Dial Adjustment) Installation and Maintenance Instructions 1. Safety information 2. Use 3.

More information

3505 Cadillac Ave - Bldg, E - Costa Mesa, CA USA. Ph (714) Fax (714)

3505 Cadillac Ave - Bldg, E - Costa Mesa, CA USA. Ph (714) Fax (714) NOW WIH 3505 Cadillac Ave - ldg, E - Costa Mesa, CA. - 92626 - USA. Ph (714) 751-7512 Fax (714) 751-0213 he Ashcroft Duragauge pressure gauge is the finest production gauge on the market for industrial

More information

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

INSTALLATION, OPERATION AND MAINTENANCE GUIDE INSTALLATION, OPERATION AND Placement in Pipeline System When installing Process Development & Control s ElastoTITE Elastomer-Hinged Check Valves in a pipeline, a minimum of five pipe diameters should

More information

780S Ultra High Purity Series

780S Ultra High Purity Series Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no seperate temperature or pressure inputs required Field adjustment of critical flow meter settings via on-board

More information

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment) 3810050/5 IM-P381-01 CH Issue 5 SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment) Installation and Maintenance Instructions 1. Safety information 2. Use 3.

More information

SOLFRUNT Model /2" (63mm) and 4" (100mm) Stainless Steel Gauges

SOLFRUNT Model /2 (63mm) and 4 (100mm) Stainless Steel Gauges LFG - 14 LIQUID FILLED GAUGES SOLID FRONT STYLE SOLFRUNT Model 659 2-1/2" (63) and 4" (100) Stainless Steel Gauges DESCRIPTION When safety is your top priority, AMETEK U.S. Gauge offers the Model 659 Series

More information

Bristol Thermometer Systems Class 1 - Liquid Filled

Bristol Thermometer Systems Class 1 - Liquid Filled 801ds4b / D301571X012 April 22, 2008 - Page 1 There are two types of Liquid-Filled Thermometer Systems available. Class 1A - Fully-compensated, and Class 1B - Case-compensated. Class 1A Systems are designed

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

Rosemount 3159 Nuclear Qualified Remote Diaphragm Seal

Rosemount 3159 Nuclear Qualified Remote Diaphragm Seal Rosemount 3159 Nuclear Qualified Remote Diaphragm Seal FOR USE ON ROSEMOUNT 3152, 3153, AND 3154 TRANSMITTERS Qualified per: o IEEE Std 323-1974/1983/2003 o IEEE Std 344-1975/1987/2004 112 Mrad (1.12 MGy)

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

FILTER TYPE PRESSURE SNUBBER

FILTER TYPE PRESSURE SNUBBER FILTER TYPE PRESSURE SNUBBER Pressure oscillations and other sudden pressure changes can affect the delicate mechanisms of a pressure gauge or pressure transmitter. This can result in either complete failure

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information

High Precision Gauge Pressure Indicators

High Precision Gauge Pressure Indicators Series 1500 8½" Dial High Precision Gauge Pressure Indicators Series 1500 Gauges have capsule-type pressure elements up to and including the 150-psig range. Ranges of 200 psig and above have Bourdon tubes.

More information

Electro-Pneumatic Converter YT-940 SERIES

Electro-Pneumatic Converter YT-940 SERIES Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product

More information

INTERLOCKED METAL HOSE

INTERLOCKED METAL HOSE INTERLOCKED METAL HOSE HOSE FUNDAMENTALS Penflex interlocked metal hoses are made for a variety of specialized industrial applications and are available in a wide range of metals, styles and sizes. Interlocked

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications

Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications Riteflow Flowmeters Compatible with a Wide Range of Gases or Liquids for Laboratory or Plant Applications Used for flow measurements in the lab, process flows in pilot plants, metering carrier gases in

More information

Precision Liquid Settlement Array Manual

Precision Liquid Settlement Array Manual Precision Liquid Settlement Array Manual All efforts have been made to ensure the accuracy and completeness of the information contained in this document. RST Instruments Ltd reserves the right to change

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

Design Features. General Description

Design Features. General Description Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

New! SOLFRUNT 659 Stainless Steel Pressure Gauges. Process Gauges A18

New! SOLFRUNT 659 Stainless Steel Pressure Gauges. Process Gauges A18 A18 New! DESCRIPTION When safety is your top priority, AMETEK U.S. Gauge offers the new Model 659 Series SOLFRUNT Gauges. The Model 659 provides users with a solid-front and pressure-relieving back design

More information

Plok. Rapid Mating Multi-Pin Industrial Connector. Amphenol Industrial Sine Systems * Pyle Connectors Corporation

Plok. Rapid Mating Multi-Pin Industrial Connector. Amphenol Industrial Sine Systems * Pyle Connectors Corporation - Plok Rapid Mating Multi-Pin Industrial onnector mphenol Industrial Sine Systems * Pyle onnectors orporation eatures and enefits Rapid mate spring loaded, push to mate, pull to unmate coupling system

More information

Model AWG20 AWG30 AWG40 AWG20K AWG30K AWG40K

Model AWG20 AWG30 AWG40 AWG20K AWG30K AWG40K Modular Type ilter Regulator with uilt-in Pressure auge eries W ilter Regulator with uilt-in Pressure auge eries W ominal filtration rating ccessory W2 /8, /4 W3 /4, 3/8 W /4, 3/8, /2 racket Pages 424

More information

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual

Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual I854000.D Apollo Standard Port, Full Port & One Piece Flanged Ball Valves Installation, Operation, & Maintenance Manual Introduction This manual presents guidelines for the Installation, Operation and

More information

Torque Tube TB300 Digital Transmitters

Torque Tube TB300 Digital Transmitters Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid

More information

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing igh Pressure quipment Medium Pressure Valves, ittings and Tubing service igh Pressure quipment Company has developed a line of Medium Pressure products to assure safe and easy plumbing through. These needle

More information

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing

High Pressure Equipment Medium Pressure Valves, Fittings and Tubing igh Pressure quipment Medium Pressure Valves, ittings and Tubing service igh Pressure quipment Company has developed a line of Medium Pressure products to assure safe and easy plumbing through. These needle

More information

Installation and Maintenance Instruction Manual

Installation and Maintenance Instruction Manual Installation and Maintenance Instruction Manual Bi-metal Thermometer Model A and E in a configuration - pursuant to ASME B40.200: ##=E#=### or ##=ERT#=### - pursuant to EN 13190: ###=A#=### or ##=ART#=###

More information

Electropneumatic Transducer (I/P) Installation, Operation and

Electropneumatic Transducer (I/P) Installation, Operation and Nitra NCP1 Series Electropneumatic Transducer (I/P) Installation, Operation and Maintenance Instructions Ordering Information Contents Part Number I/P Transducers Output Range Input psig bar Section Description

More information

Temperature gauge Installation Guide

Temperature gauge Installation Guide Temperature gauge Installation Guide improper functioning, or damage. Additional information can be found at: CAUTION: Read this installation guide carefully before unpacking the temperature gauge. Improper

More information

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions L 100 Bubble-Tube Level System Installation, Operation and Maintenance Instructions Figure 1 Contents Section Description Page 1.0 Introduction 2 2.0 Specifications 3 3.0 Installation 3 4.0 Warranty 6

More information

IBS, INCORPORATED Index Washers W A S H E R S. Washers, Lock Alloy C-8 External Tooth C-10. Internal Tooth C-10

IBS, INCORPORATED Index Washers W A S H E R S. Washers, Lock Alloy C-8 External Tooth C-10. Internal Tooth C-10 IB, INCOPOTD Index ashers ssortments Flat asher Copper C-11 Fender asher C-9 eavy Duty C-5 Lock asher Internal & xternal tar asher C-10 ur-lock Vibration-esistant ashers C-7 Back-Up ashers luminum ound

More information

PROCEDURE TWO-PLY TESTABLE BELLOWS D 1 OF 5 TWO PLY BELLOWS TEST PROCEDURE

PROCEDURE TWO-PLY TESTABLE BELLOWS D 1 OF 5 TWO PLY BELLOWS TEST PROCEDURE PROCEDURE TWO-PLY TESTABLE BELLOWS D 1 OF 5 TWO PLY BELLOWS TEST PROCEDURE Prepared by: Pathway Piping Solutions Daniel L. Edgar, PE Pine Valley, Ca 91962 Phone: (619) 473-8248 FAX: (619) 473-8148 Pathway

More information

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 ) Series variation High damping effect and types of materials Model / appearance Metering valve with silencer Model no. SMW-6 SMW-8 FMS-M SMW- SMW- (R) M M /8 / /8 / / / / 6 8 Effective sectional area (mm

More information

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs EST Group DC2518 08/01 REV 3 12/12 Page 1 of 6 Operating Procedures for GripTight SDR & IPS Test Plugs WARNING For proper operation, GripTight plugs must be assembled as shown in Figure 1. Pressure testing

More information

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 100-1950 WEATHER STATION INSTRUCTION MANUAL Receiving and Unpacking Carefully unpack all components and compare to packing list. Notify NovaLynx Corporation immediately concerning

More information

Aquor House Hydrant V2

Aquor House Hydrant V2 Aquor House Hydrant V2 IN-WALL OUTDOOR FAUCET SYSTEM FLUSH-MOUNT QUICK-CONNECT SELF-DRAINING ANTI-SIPHON NON-FREEZE VBH-SERIES AQUOR HOUSE HYDRANT V2: WALL HYDRANT / FREEZELESS SILLCOCK Freezeless sillcock

More information

Model 130M Pneumatic Controller

Model 130M Pneumatic Controller Instruction MI 017-450 May 1978 Model 130M Pneumatic Controller Installation and Operation Manual Control Unit Controller Model 130M Controller is a pneumatic, shelf-mounted instrument with a separate

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Flange Bolt Torquing. for Resistoflex Plastic-Lined Piping Products. Torquing. Retorquing. Hydrotesting. Annual retorquing

Flange Bolt Torquing. for Resistoflex Plastic-Lined Piping Products. Torquing. Retorquing. Hydrotesting. Annual retorquing Flange Bolt Torquing for Resistoflex Plastic-Lined Piping Products Torquing When assembling flange connections, always use a full complement of clean, new high strength A193-B7 bolting. If using stainless

More information

Pressure measurement. Pressure gauges

Pressure measurement. Pressure gauges Pressure gauge Pressure measurement There are four types of pressure measurements: Measurement of absolute pressure : Measurements are made with respect to absolute pressure, for example as with atmospheric

More information

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 122

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 122 Mid-West Instrument Piston Type Differential Pressure Gauges Switches & Transmitters low cost differential pressure gauge for use in measuring the pressure drop across filters, strainers, separators, valves,

More information

Pressure gauge with plastic case

Pressure gauge with plastic case Pressure gauge with plastic case Designed to monitor pressure in systems not subjected to vibrations. Suitable for all gaseous and liquid media that will not obstruct the pressure system or attack copper

More information

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions. IMPORTANT NOTICE

SAPAG. Safety valves, type 5700 Storage, Use, Operation and Maintenance Instructions.  IMPORTANT NOTICE SAPAG IMPORTANT NOTICE Contents Important notice 1 0 Valve identification 2 1 Storage 2 2 Installation 2 3 Operation 2 4 Maintenance 3 4.1 Dismantling 3 4.2 Inspection 3 4.3 Repair 3 4.4 Assembly 4 4.5

More information

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP Model No. 80-651 Rotary Agitator INTRODUCTION Binks SG-2 TM Plus Rotary 2 Qt. Pressure Cup is ideal for component spraying and industrial applications where

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

INSTALLATION & MAINTENANCE INSTRUCTION

INSTALLATION & MAINTENANCE INSTRUCTION ARCHON Industries, Inc Liquid Level Gauges Models: BT-LLG ND-LLG INSTALLATION & MAINTENANCE INSTRUCTION Instruction No.: 1014.2 Revision Issued: 3/01/03 Approved: Engineering Manager Warning ONLY QUALIFIED

More information

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features

GFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma

More information

Tank Blanketing Pressure Regulators RHPS Series

Tank Blanketing Pressure Regulators RHPS Series www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22

More information

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection 1170850/1 IM-P117-36 ST Issue 1 MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection Installation and Maintenance Instructions 1. Safety information 2. General product information

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

EASIDEW TRANSMITTER with Current Source Output

EASIDEW TRANSMITTER with Current Source Output EASIDEW TRANSMITTER with Current Source Output INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue March 2002 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element

More information

// ADapters GUIDelines

// ADapters GUIDelines // ADapters GUIDelines ADAPTER SELECTION Selection of an appropriate ALFAGOMMA adapter for a given application depends on the fluid system operating parameters listed below and the tube material and wall

More information

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator) INTRODUCTION Binks SG-2 Plus TM Pressure Cup is ideal for component spraying and industrial applications where small batch production spraying is required. The 2 qt. capacity is sufficient to complete

More information

PRESSURE, VACUUM AND TEMPERATURE

PRESSURE, VACUUM AND TEMPERATURE 5 4 S er i es 5 4 Se r i e s PRESSURE, VACUUM AND TEMPERATURE features Compact Size Wide Selection of Adjustable Ranges: Pressure: 30 Hg Vac to 6000 psi (-1 to 413,7 bar) Temperature: -130 to 650 F (-90

More information

REFRIGERATION SYSTEM COMPONENTS

REFRIGERATION SYSTEM COMPONENTS REFRIGERATION SYSTEM COMPONENTS henrytech.com Conventional Oil Separators The function of an Oil Separator is to remove oil from the discharge gas and return it to the Compressor either directly or through

More information

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1

Bourdon tube pressure gauges with glycerine filling, for chemical applications EN 837-1 Application For aggressive gaseous and liquid media which are not highly viscous and do not crystallize. Suitable for use in corrosive atmospheres. For measurement in areas subject to high vibration levels

More information

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle SB Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing A family of API liquid ring compressors has been developed and has been in the market for nearly a decade, they are specifically made

More information

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation

Certified Accuracy. Ring Force Gauge. Models and Capacities Available. Design and Principle of Operation Certified Accuracy Ring Force Gauge The accurate measurement of mechanical forces is required in hundreds of applications from a simple weighing procedure to the calibration of testing machines and load

More information

Turbine Flowmeters for Gas Applications (Metric)

Turbine Flowmeters for Gas Applications (Metric) Turbine Flowmeters for Gas pplications (Metric) Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs.

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

3.0 Pressure Transmitter Selection

3.0 Pressure Transmitter Selection 3.0 Pressure Transmitter Selection Each Tronic Line pressure transmitter has different features to meet specific performance, environmental, and price requirements. It is not possible to describe every

More information

Powers Controls RC 195 Single Input Receiver-Controller

Powers Controls RC 195 Single Input Receiver-Controller Document No. 155-119P25 RC 195-4 Powers Controls RC 195 Single Input Receiver-Controller Description The RC 195 Single lnput Receiver-Controller is a pneumatic instrument which receives one pneumatic input,

More information

Turbine Flowmeters for Gas Applications

Turbine Flowmeters for Gas Applications Turbine Flowmeters for Gas Applications Description Flow Technology s FT Series turbine flowmeters utilize a proven flow measurement technology to provide exceptionally reliable digital outputs. Because

More information

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs

Un-Pressurized Orefice Fittings FIO EZ. Parts List and Operation Instructions TECHNICAL MANUAL. Dn 2-6 Class Lbs Un-Pressurized Orefice Fittings FIO EZ Parts List and Operation Instructions TECHNICAL MANUAL Dn 2-6 Class 150-600 Lbs US US 2 FIO EZ - MT 108-US - 05-2016 FIO EZ Important Instructions US Pietro Fiorentini

More information

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly

More information

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Description Supply pressure Pressure range Connection Device Page max. bar bar thread Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4

More information

Accu Max Limited Warranty

Accu Max Limited Warranty Form #460 Rev B Phone: 69-789-6700 Fax: 69-78-840 E-mail: sales@marshallexcelsior.com www.marshallexcelsior.com NOTE: Before installing, inspect float gauge assembly for shipping damage that may affect

More information

Laboratory Flowmeters

Laboratory Flowmeters Laboratory Flowmeters Wide selection of flow ranges measure air from 0.02 ml/min to 675 LPM or water from 0.0002 ml/min to 20 LPM High-accuracy correlated flowmeters ±2% of reading! Excellent chemical

More information

Mechanical Pressure Measurement

Mechanical Pressure Measurement Mechanical Pressure Measurement Differential Pressure Gauges Model GDP, Universal Version, with Diaphragm Element High Overpressure Safety PN 40, 100, 250 or 400 Applications Differential pressure measurement

More information

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV Vacuum egulator IV0/ eries oh AJ A45 ingle ided Connections eries AX For ease of installation and panel mounting AM AM Integrated digital pressure switch for panel mounting I -A I (Made to Order) ingle

More information

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut Regulator for 2 MPa RX 2 How to Order RX2 1 Regulator 1 Regulating pressure.5 to.85mpa {.51 to 8.7kgf/cm²}.5 to.3mpa {.51 to 3.1kgf/cm²} Thread type Nil N F Rc(PT) NPT (PF) Port size 1 2 ccessories/options

More information

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTRUCTION MANUAL Pressure Relief Device LPT INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF

More information

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø Series RM/ End lock RME Port Plug End block End block type Mounting position L Left side R Right side L side end block 0. L VVQ0000 Single unit regulator / Port plug for regulator block ø0 0 Options Note

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see mvx Principles of Operation VX No moving parts to wear or fail. Electronics can be remotely mounted up to 30.5 m (0 ft). No fluid

More information

Over 20,000 Strain Gage Target flowmeters installed since 1952.

Over 20,000 Strain Gage Target flowmeters installed since 1952. Over 20,000 Strain Gage Target flowmeters installed since 1952. Liquid, gases, superheated and saturated steam from -320 to 500 O F and up to 15,000 psi. No frictional moving parts. Designed to withstand