1 HIGH CAPACITY DRUM LOUVER
2 The s (HCD) consist of extruded aluminum blades mounted inside a rotatable drum to produce long air throws with a high degree of directional control. Rotateable drum provides 60 vertical adjustment Single blade Surface and spiral duct mounting available Individually adjustable vanes Spilt blade 2 For more information visit v100
3 ADJUSTABLE AIRFLOW PATTERN + + Featuring adjustable vanes within a rotating drum, the HCD provides exceptional air pattern control. + + Rotation of the drum allows for 60 of vertical adjustment and a positive detent mechanism locks the drum at the desired angle. + + Adjustable blades allow side-to-side directional control, while the split blade design allows for increased air pattern flexibility. + + An optional pole operator bracket allows remote adjustment of the drum from floor level, for high mounted diffusers. Drum angle detent mechanism TYPICAL APPLICATIONS The HCD provides long throws to supply air to spaces that cannot be served by ductwork and conventional outlets due to structural or architectural restrictions. This makes the HCD ideal for use in warehouses, factories, stadiums, or any large enclosed space. For demanding environments such as industrial plants, or areas where corrosion resistance is necessary, an all stainless steel option is available. EASY INSTALLATION + + The HCD is available with an optional spiral duct frame for easy installation directly onto ductwork, eliminating the need for field fabricated transitions. CONSTRUCTION + + Core style Single blade (HCD1/AHCD1) Split blade (HCD2/AHCD2) + + Material Steel (HCD1/HCD2) Aluminum (AHCD/AHCD2) + + Mounting Style Surface mount Spiral duct frame + + Options All stainless steel construction (DLSS) Pole operator bracket (POB) Steel opposed blade damper (VCS3) Heavy duty steel opposed blade damper (VCS5) Spiral duct mounting v100 For more information visit 3
4 HCD Size 6 x 9 6 x 12 6 x 15 6 x 18 6 x 30 6 x 36 6 x 42 6 x 48 6 x 54 6 x 60 Duct Velocity (fpm) Velocity Pressure (in.w.g.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Air flow is in cfm. 3. All pressures are in in. w.g. 4. The NC values are based on a room absorption of 10 db re watts and one diffuser. 5. Blanks (-) indicate an NC level below Throw data is based on supply air and room air being at isothermal conditions. 7. Throw values are measured in feet for terminal velocities of 150 fpm (minimum), 100 fpm (middle) and 50 fpm (maximum). Correction Factors Model HCD1 HCD2 Deflection NC Throw - x.85 x.73 - x.85 x.73 Total Press. - x 1.5 x 1.9 x 1.3 x 1.7 x 2.2 Based on HCD1 at 0 deflection, correction factors for other conditions as listed in table opposite. Example: 12 x 36 HCD2 Flow Rate = 1800 cfm Deflection = 15 NC = = 34 Throw (50 fpm) = 115 x.85 = 98 ft Total Pressure =.086 x 1.7 = in. w.g. 8. For units with dampers, add 7 to the NC, and multiply static pressure by For more information visit v100
5 HCD Size 10 x x x x x x x x x x 72 Duct Velocity (fpm) Velocity Pressure (in.w.g.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Air flow is in cfm. 3. All pressures are in in. w.g. 4. The NC values are based on a room absorption of 10 db re watts and one diffuser. 5. Blanks (-) indicate an NC level below Throw data is based on supply air and room air being at isothermal conditions. 7. Throw values are measured in feet for terminal velocities of 150 fpm (minimum), 100 fpm (middle) and 50 fpm (maximum). Correction Factors Model HCD1 HCD2 Deflection NC Throw - x.85 x.73 - x.85 x.73 Total Press. - x 1.5 x 1.9 x 1.3 x 1.7 x 2.2 Based on HCD1 at 0 deflection, correction factors for other conditions as listed in table opposite. Example: 12 x 36 HCD2 Flow Rate = 1800 cfm Deflection = 15 NC = = 34 Throw (50 fpm) = 115 x.85 = 98 ft Total Pressure =.086 x 1.7 = in. w.g. 8. For units with dampers, add 7 to the NC, and multiply static pressure by v100 For more information visit 5
6 HCD Size 12 x x x x x x x x x x 72 Duct Velocity (fpm) Velocity Pressure (in.w.g.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Air flow is in cfm. 3. All pressures are in in. w.g. 4. The NC values are based on a room absorption of 10 db re watts and one diffuser. 5. Blanks ( ) indicate an NC level below Throw data is based on supply air and room air being at isothermal conditions. 7. Throw values are measured in feet for terminal velocities of 150 fpm (minimum), 100 fpm (middle) and 50 fpm (maximum). Correction Factors Model HCD1 HCD2 Deflection NC Throw - x.85 x.73 - x.85 x.73 Total Press. - x 1.5 x 1.9 x 1.3 x 1.7 x 2.2 Based on HCD1 at 0 deflection, correction factors for other conditions as listed in table opposite. Example: 12 x 36 HCD2 Flow Rate = 1800 cfm Deflection = 15 NC = = 34 Throw (50 fpm) = 115 x.85 = 98 ft Total Pressure =.086 x 1.7 = in. w.g. 8. For units with dampers, add 7 to the NC, and multiply static pressure by For more information visit v100
7 HCD Size 15 x x x x x x x x x x 72 Duct Velocity (fpm) Velocity Pressure (in.w.g.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Total Pressure (in.w.g.) Flow Rate (cfm) Sound (NC) Throw (ft.) Air flow is in cfm. 3. All pressures are in in. w.g. 4. The NC values are based on a room absorption of 10 db re watts and one diffuser. 5. Blanks (-) indicate an NC level below Throw data is based on supply air and room air being at isothermal conditions. 7. Throw values are measured in feet for terminal velocities of 150 fpm (minimum), 100 fpm (middle) and 50 fpm (maximum). Correction Factors Model HCD1 HCD2 Deflection NC Throw - x.85 x.73 - x.85 x.73 Total Press. - x 1.5 x 1.9 x 1.3 x 1.7 x 2.2 Based on HCD1 at 0 deflection, correction factors for other conditions as listed in table opposite. Example: 12 x 36 HCD2 Flow Rate = 1800 cfm Deflection = 15 NC = = 34 Throw (50 fpm) = 115 x.85 = 98 ft Total Pressure =.086 x 1.7 = in. w.g. 8. For units with dampers, add 7 to the NC, and multiply static pressure by v100 For more information visit 7
8 DLSS Size Discharge Velocity (fpm) Flow Rate (cfm) x 12 Total Pressure (in. w.g.) Sound (NC) <15 < Throw (ft.) Flow Rate (cfm) x 24 Total Pressure (in. w.g.) Sound (NC) < Throw (ft.) Flow Rate (cfm) x 36 Total Pressure (in. w.g.) Sound (NC) < Throw (ft.) Flow Rate (cfm) x 60 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Flow Rate (cfm) x 20 Total Pressure (in. w.g.) Sound (NC) < Throw (ft.) Flow Rate (cfm) x 30 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Flow Rate (cfm) x 40 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Flow Rate (cfm) x 60 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Flow Rate (cfm) x 70 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Air flow cfm: Based on standard air density and isothermal conditions. 3. Noise Criteria: Noise criteria [NC] curve which is not exceeded with a Room Attenuation of 10db and based on Sound Power Level Re: watts. 4. Projection: Projection distance [THROW] in feet from the Louver discharge at which the maximum velocity has been reduced to specified terminal velocity [Vt]. 5. Discharge Velocity: Discharge Velocity in feet per minute [fpm]. 6. Terminal Velocity: Maximum velocity [Vt] in feet per minute at the specified distance from the outlet face [THROW] 200 fpm, 100 fpm, and 50 fpm respectively. Performance values for various deflection angles Deflection Angle Static Pressure [times] Throw-Projection [times] Noise Criteria NC [add] For more information visit v100
9 DLSS Size Discharge Velocity (fpm) Flow Rate (cfm) x 20 Total Pressure (in. w.g.) Sound (NC) < Throw (ft.) Flow Rate (cfm) x 40 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Flow Rate (cfm) x 60 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Flow Rate (cfm) x 70 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Flow Rate (cfm) x 20 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Flow Rate (cfm) x 40 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Flow Rate (cfm) x 50 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Flow Rate (cfm) x 60 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Flow Rate (cfm) x 70 Total Pressure (in. w.g.) Sound (NC) Throw (ft.) Air flow cfm: Based on standard air density and isothermal conditions. 3. Noise Criteria: Noise criteria [NC] curve which is not exceeded with a Room Attenuation of 10db and based on Sound Power Level Re: watts. 4. Projection: Projection distance [THROW] in feet from the Louver discharge at which the maximum velocity has been reduced to specified terminal velocity [Vt]. 5. Discharge Velocity: Discharge Velocity in feet per minute [fpm]. 6. Terminal Velocity: Maximum velocity [Vt] in feet per minute at the specified distance from the outlet face [THROW] 200 fpm, 100 fpm, and 50 fpm respectively. Performance values for various deflection angles Deflection Angle Static Pressure [times] Throw-Projection [times] Noise Criteria NC [add] v100 For more information visit 9
10 Product Improvement is a continuing endeavour at Price. Therefore, specifications are subject to change without notice. Consult your Price Sales Representative for current specifications or more detailed information. Not all products may be available in all geographic areas. All goods described in this document are warranted as described in the Limited Warranty shown at priceindustries.com. The complete Price product catalog can be viewed online at priceindustries.com. Price is a registered trademark of Price Industries Limited Printed in Canada. v100
-4.~1~ S L 0 T D I F F U S E R S
\ I R DISTR I BUTION SPECIALIST -4.~~ S L 0 T D I F F U S E R S SLSD RLSD Supply Linear Slot Diffuser with hit & miss damper, and with deflectors. Return Linear Slot Diffuser with hit and miss damper,
More informationfor Pleasant & Healthy Air-Distribution ISO 9001:2000 Linear Slot Diffusers Product Bulletin 133-D
for Pleasant & Healthy Air-Distribution ISO 9001:2000 Product Bulletin 133-D Linear Slot Diffusers Pleasant.. Serene.. YOU & DASCO... Since 1964 Partners for good health INTRODUCTION Linear slot diffusers
More informationEXTRUDED ALUMINUM SQUARE AND RECTANGULAR DIFFUSERS
INDUSTRIAL REGISTRATION NO.353 EXTRUDED ALUMINUM SQUARE AND RECTANGULAR DIFFUSERS SQUARE AND RECTANGULAR FLUSH CEILING DIFFUSERS OUTSTANDING FEATURES: Extruded aluminum construction 1-2-3-4 way throw patterns.
More informationSafidDampers. Class 1A & Class 1 Low Leakage Volume Control Damper ( Flange Type ) SPK Standard Construction. Description SPK
( Flange Type ) SPK 30 400 Standard Construction FRAME: 60mm x 30mm x.5mm (6 Ga.) galvanized steel formed channel for flange connection. BLADES: 00mm, 5mm and 50mm wide airfoil shaped blades extruded aluminum.
More informationAdjustable swirl diffuser ODZA TECHNICAL DATA
Adjustable swirl diffuser ODZA TECHNICAL DATA 2 Adjustable swirl diffuser ODZA Adjustable ceiling swirl diffuser ODZA is intended for commercial and industrial buildings with a large room volume and high
More informationGENERAL OVERVIEW GENERAL OVERVIEW
GENERAL OVERVIEW A GENERAL OVERVIEW Traditional HVAC systems in most commercial buildings today employ Overhead Mixing (Mixed Ventilation, MV) to meet both outdoor air ventilation and space conditioning
More informationTurbo Blowers. Combustion Excellence Since Features. Benefits
Turbo Blowers Features Integral molded scroll design Turbine bladed impeller Steel inlet guard Precisely balanced impellers eliminate vibration Complete line of available accessories for adapting to any
More informationacculink platinum zv zoning system
acculink platinum zv zoning system Components: AZONE950AC52ZA ZZONEPNLAC52ZA AZONE940 ZZONEEZPAC52ZB Platinum 950 Control Zone Panel Kit up to 4 zones Included: Discharge Air Temp sensor Static Pressure
More informationCEILING DIFFUSERS technical CONTROL THE AIR YOU BREATHE. types -CD, CAB. Europair Africa a division of Performancair Products Africa (Pty) Ltd
CEILING DIFFUSERS technical types -CD, CAB Europair Africa a division of Performancair Products Africa (Pty) Ltd tel +27 11 974 2425 fax +27 11 974 7251 web www.europair-africa.com email: info@europair-africa.com
More informationCLB 3 ATTRACTIVE JOINABLE LINEAR PROFILE EASILY ACCESIBLE VOLUME ADJUSTMENT INCLUDED FLEX CLAMP HEATING AND COOLING TERMINAL REHEAT AVAILABLE
CONSTANT VOLUME LINEAR BAR CEILING DIFFUSER CLB 3 ATTRACTIVE JOINABLE LINEAR PROFILE EASILY ACCESIBLE VOLUME ADJUSTMENT INCLUDED FLEX CLAMP HEATING AND COOLING TERMINAL REHEAT AVAILABLE CONTROL THE PERIMETER
More informationLayout Guidelines. Overview
TECHNICA RESOURCES ayout Guidelines Included are the design layout guidelines for evaporative cooling products in several situations typically encountered by designers. These guidelines represent minimum
More informationCADENZA
---------------------------------------------- ---------------------------------------------------------------------- Attenuator with aerodynamically shaped splitters for rectangular ducts GENERAL has
More informationCALMO
---------------------------------------------------- Sound attenuator with recessed connection for rectangular ducts ---------------------------------------------------------------------- GENERAL is, due
More informationC O L M A N. Air Distribution SWIRL DIFFUSERS DRS SERIES DRS SERIES
C O L M N ir Distribution E N G I N E E R E D I R P R O D U C T S SWIRL DIFFUSERS DRS SERIES DRS SERIES D SERIES SWIRL DIFFUSERS pplication The DRS, DQS, DCS and DSS series of fixed circular swirl diffusers
More informationBULLETIN FA-300. February 1999 AXIAD II. Adjustable Pitch Airfoil Axial Flow Fan
BULLETIN FA-300 February 1999 AXIAD II Adjustable Pitch Airfoil Axial Flow Fan AXIAD II The axial flow fan with: High efficiency Low sound level Adjustable pitch blades Complete range of accessories Axial
More informationMANAGEMENT PROCEDURE FOR LABORATORY VENTILATION
UNIVERSITY OF ALASKA FAIRBANKS SAFETY SYSTEM POLICY AND PROCEDURE DOCUMENT NUMBER: 508 ISSUE DATE: SEPTEMBER 1996 SUBJECT: Management Procedure for Laboratory Ventilation MANAGEMENT PROCEDURE FOR LABORATORY
More informationSupply air diffuser ROFB, RPFB
Supply air diffuser ROFB, RPFB ROFB and RPFB are supply air diffusers with an integrated plenum box for freely suspended installation in a ceiling. The diffuser ROFB comes with an unperforated and RPFB
More informationEvaporator (DX) Freon Applications 1 12 Tons MHF
Evaporator (DX) Freon Applications 1 12 Tons > > Used For small to medium freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client
More informationThe System Curve, the Fan Curve, and the Operating Point
The System Curve, the Fan Curve, and the Operating Point AIHA-RMS Sept. 12, 2018 Keith D. Robinson, P.E. Overall Objective To equip an Industrial Hygienist with the skills necessary to document the performance
More informationSeries 3000 Layout Guidelines
Series 3000 Layout Guidelines Open circuit cooling towers, closed circuit cooling towers, and evaporative condensers all depend upon an adequate supply of fresh, ambient air to provide design capacity.
More informationSand Trap Louvers. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) SAND TRAP LOUVERS
DUCT VENTILATION AIR CONDITIONING Co. (.L.L.) SAND TRAP LOUVERS DUCT VENTILATION AIR CONDITIONING Co. (.L.L.) DOA- QATAR - PONE: +974-440118 - +974-440119 - FAX: +974-440117 DVAC, One Of The Premium orkshops
More informationHVAC Air Duct Leakage. Tech University 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA
HVAC Air Duct Leakage Tech University 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA Learning Objectives Understand the difference between System leakage and Duct leakage Understand
More informationEngineered Air Nozzles reduce noise levels and air costs.
Air Nozzles Engineered Air Nozzles reduce noise levels and air costs. " Go Green" by upgrading your blowoff, cooling, and drying operation to the award winning Super Air Nozzles! What Are Air Nozzles?
More informationDESIGN OF AN EFFECTIVE LOW PRESSURE VAV AIR DISTRIBUTION SYSTEM
ABSTRACT The aim of this paper is to provide the air conditioning engineer with a clear set of guidelines for use in the design of the air distribution system for a low pressure Variable Air Volume system.
More informationPressure and Vacuum Switches for Process Applications
for Process Applications Form 216 SOR Pressure are rugged field-mounted instruments. The pressure sensing element of the SOR pressure switch is a force-balance, piston-actuated assembly. The sensing element
More informationRound duct nozzle jet diffuser Model DSA-RR
Round duct nozzle jet diffuser Model DSA-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary
More informationCOMMERCIAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet
For Door Heights To 8 (environmental separation) COMMERCIAL LOW PROFILE 8 Data Sheet STANDARD CONSTRUCTION 8 1/2 high x 13 1/2 deep 1/5 hp two speed motor(s) Factory installed fan speed/heat switch White
More informationARCHITECTURAL LOW PROFILE 8 Electric Heated Air Curtain Data Sheet
For Mounting Heights To (environmental separation) ARCHITECTURAL LOW PROFILE Electric Heated Air Curtain Data Sheet STANDARD CONSTRUCTION 7 1/2 high x 13 ¾ deep 1/5 hp motor(s) - ten speeds Factory installed
More informationMaterial Handling Hose
Novaflex 5000 Slurry King Hose Pure Gum Liner Tough, versatile alternative to inflexible, cumbersome steel tubing. The easy handling and reusable quick-fastening flange system make installation a snap.
More informationSizes JNŽ-6, ANŽ-3, ANŽ-4
JNŽ-6, ANŽ-3, ANŽ-4 Application are used in all kinds of low pressure air conditioning, air heating ind ventilation, where it is necesary to equalise the pressure between adjacent rooms. They can be applied
More informationLiquid ring compressors
Liquid ring compressors KPH 95652 Compression pressures: 6 to 12 bar(g) Suction volume flow: 2960 to 3600 m³/h 78 to 174 psig 1742 to 2119 cfm DESIGN TYPE SIHI liquid ring compressors are displacement
More informationLiquid ring vacuum pumps in compact design
Liquid ring vacuum pumps in compact design, Pressure range: Suction volume flow: 33 to 113 mbar 3 to 58 m³/h CONSTRUCTION TYPE SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated and
More informationExcellent Duct Systems Require Design, Not Guesswork!
Design Advisory #2: CAS-DA2-2003 Excellent Duct Systems Require Design, Not Guesswork! Duct System Design Guide: Chapter 2 HVAC system performance is only as good as it s weakest link. Unfortunately, duct
More informationReset Volume Controller 2 Reversing Relay 3 Air Valve Actuator 4 Lower-of-Two-Pressures Relay 4 Diverting Relay 5 Higher-of-Two-Pressures Relay 5
Item Page Reset Volume Controller 2 Reversing Relay 3 Air Valve Actuator 4 Lower-of-Two-Pressures Relay 4 Diverting Relay 5 Higher-of-Two-Pressures Relay 5 Gradual Switch 6 Electric / Pneumatic (E.P.)
More informationAutomatic extractor outlet
L-07-2-01e Automatic extractor outlet Type HFA Contents Application Realisation Operation Safety instructions Contents Application Realisation Operation Safety instructions 2 Connection diagram Dimensions
More informationfor Asia / Pacific Radial outlet RA-N3... DS 4134 AUS /
for Asia / Pacific Radial outlet RA-N... DS AUS./ Radial outlet RA-N Preliary remarks KRANTZ KOMPONENTEN radial outlets of type RA-N have fixed radial vanes. They generate high-quality, diffuse supply
More informationAIR DIFFUSION INDUCTIVE MICRO-PERFORATED DUCTS
cop1 SISTEMI INNOVATIVI TRATTAMENTO ARIA AMBIENTE AIR DIFFUSION INDUCTIVE MICRO-PERFORATED DUCTS SELECTION CATALOGUE JULY 2012 EDITION INTRODUCTION The DLD air diffusion perforated ducts are born with
More informationINFUSION SYSTEM (110V) (220V) USER S MANUAL
INFUSION SYSTEM 20-6000-00 (110V) 20-6005-00 (220V) USER S MANUAL 8000 South Kolb Road Tucson, AZ 85756 Phone 800.528.1597 Fax 520.885.1189 www.wellsgrp.com email: sales@wellsgrp.com GENERAL DESCRIPTION
More informationFLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN
FLOW CONSIDERATIONS IN INDUSTRIAL SILENCER DESIGN George Feng, Kinetics Noise Control, Inc., 3570 Nashua Drive, Mississauga, Ontario Vadim Akishin, Kinetics Noise Control, Inc., 3570 Nashua Drive, Mississauga,
More informationFlex-Kleen CT Series Pulse-Jet Dust Collectors For high pressure/high vacuum applications
Bulletin CT Flex-Kleen CT Series Pulse-Jet Dust Collectors For high pressure/high vacuum applications CT (Circular Tank) COLLECTORS... especially effective for dusting problems in drying, grinding and
More informationSTRUCTURE S-65 PURPOSE SPILLWAY OPERATION
STRUCTURE S-65 This structure is a reinforced concrete, gated spillway with discharge controlled by three cable operated, vertical lift gates, and a reinforced concrete lock structure with two pairs of
More informationGANTRY CRANES CAPACITIES: SPANS: TRACKS: OPTIONS: Up to 5 tons Up to 30' Steel Fixed or Adjustable
GANTRY CRANES CAPACITIES: SPANS: TRACKS: OPTIONS: Up to 5 tons Up to 30' Steel Fixed or Adjustable Material Handling Solutions For Your Unique Applications Since 1977, Gorbel has been an innovator and
More informationCOMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B. By Kimbal A. Hall, PE
COMPUTATIONAL FLOW MODEL OF WESTFALL'S LEADING TAB FLOW CONDITIONER AGM-09-R-08 Rev. B By Kimbal A. Hall, PE Submitted to: WESTFALL MANUFACTURING COMPANY September 2009 ALDEN RESEARCH LABORATORY, INC.
More information3200 WHOLE HOUSE FAN INSTALLATION & OPERATION MANUAL
ORDER #: S/N: (Required for Warranty) 3200 WHOLE HOUSE FAN INSTALLATION & OPERATION MANUAL Thank you for purchasing this AirScape whole house fan. Your fan has been designed to provide your home with natural,
More informationSafety switch renewal parts
Renewal Parts RP00801001E Supersedes July 2002 Safety switch renewal parts Contents Description Page Heavy-duty switch....2 Line shield....3 Operating mechanism....3 Operating handle....3 Fusible switching
More informationsealed self retracting lifeline
Supplemental Instruction to: Sealed Self Retracting Lifeline (See back page for specific model numbers.) Supplemental Instruction User Instruction Manual sealed self retracting lifeline Use this Supplemental
More informationBannerSaver Bracket System
Featuring BannerSaver Bracket System Eliminate Wind Damage and Keep Your Banners Tight and Straight With Patented BannerSaver Preferred by municipal engineers Excellent for city special events, festivals,
More informationOperating Instructions for Cobra and Lynx Duct Leakage Testers
Operating Instructions for Cobra and Lynx Duct Leakage Testers Table of Contents Introduction Introduction... 2 Safety Precautions Safety Precautions.. 2 Prior to Testing System Preparation.. 4 Power Requirements...
More informationPrecision Rotary Airlocks and Diverter Valves
Precision Rotary Airlocks and Diverter Valves Utilizing over 40 Years of Mac Process Bulk Material Conveying Technology Airlocks and Diverters Schenck Process offers a wide range of airlocks and diverter
More informationRectangular-k27 Duct and Fittings Dimensions
An enterprise of United McGill Corporation - Founded in 1951 One Mission Park Groveport, Ohio 43125-1149 614/836-9981, Fax: 614/836-9843 E-mail: mcgillairflow@compuserve.com Web site: http://www.mcgillairflow.com
More informationCHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222
PATENT #: 5,160,222 PHONE: (913)677-5777 FAX: (913)677-067 E-Mail : techair@techairinc.com www.techairinc.com CHECK-KLEEN DIVERTER A PNEUMATIC CONVEYING SYSTEM FLAP-CHECKS exposed to product air stream
More informationSizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios
Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios Yunlong (Jason) Liu, PhD, PE HNTB Corporation Sean Cassady, FPE HNTB Corporation Abstract Extraction
More information3200 whole house FAN INSTAllATION & OpERATION MANuAl
OrDer #: s/n: (required for Warranty) 3200 whole house FAN INSTAllATION & OpERATION MANuAl Thank you for purchasing this Airscape whole house fan. Your fan has been designed to provide your home with natural,
More informationLiquid ring vacuum pumps in compact design
Liquid ring vacuum pumps in compact design LEM 25, LEM 5 Pressure range: Suction volume flow: 33 to 113 mbar 4 to 6 m³/h CONSTRUCTION SIHI liquid ring vacuum pumps are displacement pumps of uncomplicated
More informationHeavy Duty Type LT Spring Operated Cable Reeling Drums
Heavy Duty Type LT Spring Operated SIMBAL type LT spring operated cable reeling drums are designed for cylindrical or spiral winding of any suitable reeling cable for transmission of power, control or
More information6. EXPERIMENTAL METHOD. A primary result of the current research effort is the design of an experimental
6. EXPERIMENTAL METHOD 6.1 Introduction A primary result of the current research effort is the design of an experimental setup that can simulate the interaction of a windmill with a vortex wake and record
More informationProduct Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)
CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE Product Data (3619, 4823, 6025) A06009 A07904 The CAPMP and CARMP evaporator coils incorporate proven standards for reliable system operation and
More informationCSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING
CSC-2000 SERIES Reset Volume Controllers MADE IN U.S.A. DESCRIPTION The CSC-2000 series are designed for use on VAV terminal units in HVAC systems. These are submaster air velocity controllers whose velocity
More informationCauses and Remedies to 7 Instability Patterns in Blown Film Extrusion
Causes and Remedies to 7 Instability Patterns in Blown Film Extrusion Paul Waller, Plastics Touchpoint Group, Inc., Thornhill, Canada Abstract Bubble instability in blown film extrusion creates problems
More informationPrecision Duct Systems 4570 Commerce Cir SW Atlanta, GA Phone (404)
Project Name: Engineer: Contractor: Section Number: Date Submitted: Date Approved: Pressure Class: Material Type: Connections: 2005 Up to 10 wg 1995 2 wg pos 1995 4 wg pos 1995 10 wg 2005 neg WG: 1995
More informationAir Operated Hydraulic Pumping Systems to 50,000 psi
High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air
More information15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146
Operation and Maintenance Manual 15000 Series Exhausting Arm - Wall Mount Models: 15076/15106/15146 MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 Receiving Assembly Information 15000 Series Exhausting
More informationIndustrial Grade Portable Outlet Boxes and Coverplates
Product Bulletin for Portable Outlet Boxes Industrial Grade Portable Outlet Boxes and Coverplates Leviton s line of temporary power solutions now includes industrial grade portable outlet boxes and coverplates.
More informationSecurity and confidence at height.
A Security and confidence at height. Vertical Systems DISTRIBUTED BY M DBI-SALA Vertical Systems are designed to complement your ability to work while meeting all applicable OSHA and ANSI standards. Vertical
More informationMZT PUMPI PUMP YOUR WAY TO SUCCESS MULTISTAGE CENTRIFUGAL PUMPS - MS,DMS,MSTD,MSS
UM YOUR WAY TO SUCCESS MULTISTAGE CENTRIFUGAL UMS - MS,DMS,MSTD,MSS Catalog 9 CONTENT GENERAL DATA.................................................... 3 Description.......................................................
More informationApplied Fluid Mechanics
Applied Fluid Mechanics 1. The Nature of Fluid and the Study of Fluid Mechanics 2. Viscosity of Fluid 3. Pressure Measurement 4. Forces Due to Static Fluid 5. Buoyancy and Stability 6. Flow of Fluid and
More informationChilled beam iq Star WEGA II
Chilled beam iq Star WEGA II Key features Ventilation Water Heating and cooling Adjustable induction Flow Pattern Control In option: Demand Controlled Ventilation, Pressure independent, Electrical heating,
More informationCSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING
CSC-2000 SERIES Reset Volume Controllers MADE IN U.S.A. DESCRIPTION The CSC-2000 series are designed for use on VAV terminal units in HVAC systems. These are submaster air velocity controllers whose velocity
More informationGas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling
PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel tapered design primary heat exchanger with crimped construction for long
More informationDN300 DN2000 C Plunger Valve
ל DN300 DN2000 C Plunger Valve P.O.B 46 MOSHAV SHTULA WESTERN GALILEE 2286500 Tl. +972-(0)77-6656101, Fax. +972-(0)77-6656196 Website: www.saisanketvalves.com www.saisanket.com email: saisanket@saisanket.com
More informationKrantz Components. Multifunction Sail AVACS. Cooling and Heating Systems
Multifunction Sail AVACS Cooling and Heating Systems 2 AVACS Air Ventilation And Cooling System 3 System design Air diffuser box Air connection Sound absorbers (optional) Cooling element with heat conducting
More informationGlycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers
Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Air Technology Systems, Inc. Table of Contents Section - 1 Table
More informationVertical Wind Energy Engineering Design and Evaluation of a Twisted Savonius Wind Turbine
Design and Evaluation of a Twisted Savonius Wind Turbine Ian Duffett Jeff Perry Blaine Stockwood Jeremy Wiseman Outline Problem Definition Introduction Concept Selection Design Fabrication Testing Results
More informationRoughneck TM Mesh Slings
Roughneck TM Slings ROUGHNECK WIRE MESH SLINGS Widely used in metalworking shops and steel warehouses where loads are abrasive, hot or tend to cut web slings Features and Benefits Promotes Safety Steel
More informationGUARDIAN FALL PROTECTION
2015 V2 GUARDIAN FALL PROTECTION Product Mini Catalog 2015 For more information, go to www.guardianfall.com or call 800.466.6385 OUR VISION TO ALWAYS BE THE MARKET S FIRST CHOICE FOR FALL PROTECTION AND
More informationby Master Halco ANCHOR GATE SYSTEMS Swing Gates Overhead Slide Gates Cantilever Slide Gates Vertical Lift Gates Fencing Without Boundaries.
by Master Halco ANCHOR GATE SYSTEMS Swing Gates Overhead Slide Gates Cantilever Slide Gates Vertical Lift Gates Fencing Without Boundaries. The Better Way To Build Your Cantilever Slide Gates... The Principle
More informationWater Cooling and Evaporator Coils. Types HI-F5 and E-F5. Catalog 411-9
Water Cooling and Evaporator Coils Types HI-F5 and E-F5 Catalog 411-9 Table of Contents Introduction.... 3 HI-F5 and E-F5 Water Cooling and Evaporator Coils 3 Daikin SelectTools for Contractor Coils...3
More informationNow with. Covers. Grade Level Box BULK FEATURES TESTING CRITERIA TECHNICAL SPECIFICATIONS
Grade Level Box BULK 24 /608 mm depth FEATURES Upgradeable Lightweight/Strong (TIER 22) Patented Anti-Slip Technology Anti-Seize Bolt Technology Industry Leader in Anti-Trip Hazard Prevention Superior
More informationAtmospheric Vent Silencers. Industrial & Marine Silencers
tmospheric Vent Silencers Industrial & Marine Silencers Maximum performance Minimum fuss Industrial and Marine Silencers (IMS) designs and builds products for organisations engaged in power generation,
More informationSeamax Boat Bimini Top User Manual
Seamax Boat Bimini Top User Manual Size A / B / C 3 BOW Size D / E / F 4 BOW Thanks for your purchase. Seamax Bimini Top has built-in the aluminum eye-end fitting to install on standard oar lock pin (diameter
More informationSECTION TESTING, ADJUSTING, AND BALANCING CONTRACT NO SECTION TESTING, ADJUSTING, AND BALANCING
SECTION 15990 TESTING, ADJUSTING, AND BALANCING PART 1 -GENERAL 1.01 GENERAL A. This section of the Specifications covers testing and balancing of environmental systems, including, but not limited to distribution
More informationHow Inlet Conditions Impact Centrifugal Air Compressors
How Inlet Conditions Impact Centrifugal Air Compressors Richard Stasyshan, CAGI Technical Consultant and the Centrifugal Compressor Section of the Compressed Air & Gas Institiute (CAGI). Centrifugal technology
More informationFewer parts. Fast installs. ANSI Compliant. 3M DBI-SALA Lad-Saf Flexible Cable Vertical Safety Systems
Fewer parts. Fast installs. ANSI Compliant. 3M DBI-SALA Lad-Saf Flexible Cable Vertical Safety Systems 3M DBI-SALA Lad-Saf Flexible Cable Vertical Safety Systems Adding or upgrading your vertical safety
More informationPROVIDING QUALITY SOLUTIONS FOR THE AUDIOMETRIC INDUSTRY
PROVIDING QUALITY SOLUTIONS FOR THE AUDIOMETRIC INDUSTRY PRODUCT OPTIONS AMB Portable Series: Booths consist of 2 or 3 inch panels with integrated ventilation in the roof and floor. AMB 410: Consists
More informationWe put it all on the line, so you don t have to.
3M DBI-SALA 8 mm Permanent Horizontal Lifeline Systems We put it all on the line, so you don t have to. Smarter software. Stronger hardware. Easier installation. How do you improve on one of the best permanent
More informationTwo-Wheel Hand Trucks
Two-Wheel Hand Trucks Lightweight, high strength aircraft grade aluminum. Engineered for optimum strength to weight ratio. Dual clinch aircraft style riveted construction. Personalization available to
More informationWhisperValue DC. The ideal Multi-Family Solution High Performance Built for the Long Run
WhisperValue DC The ideal Multi-Family Solution High Performance Built for the Long Run The ideal Multi-Family Solution - Cost Efficient Code Compliance Made Easy Though small in size, Panasonic s WhisperValue
More informationMulti-Flow Product Catalog
Multi-Flow Product Catalog Multi-Flow offers a variety of multi-purpose reducing connectors (06005-0600N, 12005-1200Q, and 18005-1800Q) that allow for complete flexibility in the design of drainage patterns.
More informationRetractable. Dual Leg. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment
3M Occupational Health and Environmental Safety Fall Protection Equipment Dual Leg Retractable User Instructions User Instructions for the 3M TM Dual Leg Retractable Important: Keep these User Instructions
More informationHoses and Lances 20,000 PSI
Jetstream provides a full arrangement of hoses and flex lances for ultra high pressure waterblasting. The hoses and lances are designed to be durable and reliable for any 20,000 psi application. A large
More informationLiquid ring compressors
Liquid ring compressors KPH 85220, KPH 85227 Compression pressures: Suction volume flow: 2 to 7 bar 940 to 1450 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors
More informationObserving Climate - Surface
Observing Climate - Surface 3-1 Wind Science Concepts Definition Anemometer Wind Vane Velocity Vectors Speed Direction Energy - Kinetic Energy 3-2 Definition How would you define the wind? Wind velocity
More informationAIR CONDITIONERS WA14**W SERIES
FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationMedium voltage standard-duty, heavyduty, and extreme-duty single-phase, unfused capacitor units and accessories
Power Capacitors Catalog Data CA230003EN Supersedes January 2017 COOPER POWER SERIES Medium voltage standard-duty, heavyduty, and extreme-duty single-phase, unfused capacitor units and accessories General
More informationLiquid ring compressor
Liquid ring compressor KLH 47005, KLH 47105 Compression pressures: Suction volume flow: 2 to 11 bar 56 to 65 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors of
More informationTRAVSMART permanent single-cable horizontal lifeline system
The Travsmart single-line system provides a smooth travel. It allows the traveler to move freely over the intermediate anchors, minimizing wear and eliminating user assistance. The user s hands remain
More informationFan and air movement essentials
1 Properties of air For the purposes of this section we will assume that it is air that will be moved by the various types of fans. The air we breathe is made up of a mixture of gasses - nitrogen 78%,
More informationConventional Ship Testing
Conventional Ship Testing Experimental Methods in Marine Hydrodynamics Lecture in week 34 Chapter 6 in the lecture notes 1 Conventional Ship Testing - Topics: Resistance tests Propeller open water tests
More informationRadiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G
Data sheet Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G EN 215 Application RA2000 013G2910 Built-in sensor RA2000 013G2920 tamperproof RA2000 013G5062 remote temperature
More information