-4.~1~ S L 0 T D I F F U S E R S

Size: px
Start display at page:

Download "-4.~1~ S L 0 T D I F F U S E R S"

Transcription

1 \ I R DISTR I BUTION SPECIALIST -4.~~ S L 0 T D I F F U S E R S SLSD RLSD Supply Linear Slot Diffuser with hit & miss damper, and with deflectors. Return Linear Slot Diffuser with hit and miss damper, without deflectors. FAISAL JASSIM INDUSTRIES (L.L.C.) P 0. Box: 87 Dubai, U.A.E. Te: Fax: ~ flowtech@fjtco.com Website:

2 A I R D I S T R I B U T I O N S P E C I A L I S T APPLICATIONS FLOWTECH Linear Slot Diffuser (LSD) is a high capacity slot diffuser suited to a wide range of applications. With its pleasant aesthetic appearance it can be used in variety of prestigious locations such as Lobbies, Dinning Halls, Hotels, Palaces and Buildings Entrances where aesthetic is architecturally critical. For this purpose FLOWTECH LSD can be supplied in a straight or curved shape with a wide variety of powder coated colors. Functionally, Linear Slot Diffusers are used in large open areas where perimeter supply or return is required. For this purpose, FLOWTECH LSD is provided with unique curved design of air deflecting vanes which can be adjusted as required to achieve precise control of air flow direction. Usually directional control is required towards perimeter heat source or away from adjacent glass areas. With its steady performance at variable air flow rates, FLOWTECH LSD can be effectively used as part of VAV systems. For this purpose, FLOWTECH LSD can be combined with unitary plenum boxes of designer choice. FLOWTECH LSD can be used as supply air diffuser, return air diffuser or dummy ceiling diffuser for decorative purposes. Rev. 0:00/ E-

3 FLOW ~TECH AI R DISTRIBUTION SPECIALIST Supply Linear Slot Diffuser (SLSD) Product Features: Frame and curved deflection blades are made of extruded aluminum alloy 0 to T Heat Treatment. Available with Hit and Miss Damper of Gl sheet t o control air flow rate w ithout affecting the air flow patterns. I 80 fully adjustable air flow patterns by means of two air deflector blades per slot. Both Deflector Blades and Hit & Miss Damper are powder coated with black color. Available in I to 8 slots. and I " (mm). For maximum rigidity, profi les are fixed at equally spaced intervals using Screw Rods and cylindrical shims of mm dia, made of extruded aluminum Maximum one piece length is 0mm. Larger pieces are jointed using hairline butt joints held by special alignment strips to ensure continuous unbroken runs Curved Segments are available for both sidewall curves (CS) and ceiling curves (CP), with minimum radius of curvature of I OOOmm. Surface mount design Standard Slot Width is I /" ( mm), /4"(0mm) ~ A, ~ ~ B: Type SLSD-S with deflect ors with hit and miss dampers E- Rev. 0:00/ I

4 - If) If) FLOW -"-~TECH AIR D ISTRIBUTION SPECIALIST Standard Sizes: Standard Slot Size mm -- No. of I Slot Slot Slot 4 Slot Slot Slot Slots Neck Size A(mm) Flange Size B(mm) 7 Slot Slot 48 8 Standard Slot Size 0mm No. of I Slot Slot Slot 4 Slot Slot Slots Neck Size A(mm) Flange Size B(mm) Slot 0 7 Slot Slot 0 4 Standard Slot Size mm No. of Slots Neck Size A(mm) Flange Size B(mm) I Slot Slot Slot 4 Slot Slot Slot Slot Slot 77 B Ji~- Type SLSD-S with deflectors with hit & miss dampers (with 90deg end cap) Rev. 0:00/ I E-

5 FLOW~~ECH AIR DISTRIBUT I ON SPECIALIS T Available in powder coated RAL 900 or 90 as standerd color. Hit and miss damper are powder coated in black color as standard. Other powder coated finishes are available on request Plenum By Others w w ~ r ~ ~ ~ yy Ad'"""''''""' ~ ~ By Others ~ ~ ~ y y Y0 g Bndge Bracket By Others II ~ /_ Supportng Clamp False Celing _/ By Others ~ I ~.- li!hc:_.!!!'! ~-=.~ \()( ~ I ~ - Recommended Mounting of Linear Sloe Diffuser with a Plenum Box Spgot for flexible duct connection Ahgmng i Slot dffuser Mountin of Linear Slot Diffuser With a Plenum Box E-4 Rev. 0:00/ I

6 FLow~TEcH AIR D ISTRIBUTION SPECIALIST END CAP (EC) 0mmX0mm "L" shaped removable End Caps are supplied free with each full length to suit any LSD size. The end cap allows the extending or t he shortening of slot diffusers lines without replacing existing pieces. A mitred end cap is available upon request. I i~--~~ Corner Piece Ceiling Type (CPC) Available in any combination of X,Y &.. X Slot Diffuser with End Cap (EC) X (mm) Y (mm) l.(degree) can be of any angle between 4 and / ~ / y Ceiling Type Corner (CPC) Corner Piece Wall Type (CPW) mmxmm up to 00mmX 00mm Comer Pieces are available at 4 to angles for all standard slot sizes. Curved Slot Diffusers (CSD) Slot diffusers can be supplied with ceiling type curve to a minimum of I meter. Our Technician will assist in taking site measurments for special curvature. -- Wall Type Corner (CPW) --.A ' Curved Slot Diffuser (CSD) Mlred end cap lmear slot 0 user Rev. 0:00/ E-

7 A I R D I S T R I B U T I O N S P E C I A L I S T ACCESSORIES Plenum Boxes: Suitable for supply and exhaust linear slot diffuser. Galvanized steel construction. Supply as standard with one side inlet per metre length. Special constructions available on request. Option: Manual quadrant damper, code Q Sizes: Maximum length available 000mm Other Ø D available on request. V V H+0 H+0 ØD ØD Plenum boxes, code P Insulated plenum boxes, code PI mm Slots No. of Slots H Ø D V mm Slots No. of Slots H Ø D V mm Slots No. of Slots H Ø D V E- Rev. 0:00/

8 FLOW -~TECH AIR D ISTRIBUTION SPECIALIST DDDD-DD-DDDD-DDDD RAL Code Color Length in mm or inch No. of Slots SLSD Stands for SLSD model, -Slots, 00mm length and powder coated to RAL-90 color code. A ll igning strips are provided w it h each length of m. For Curved Segments, remark of curvature and plan of curvature shall be included in t he order. Our technicians are available, at your request, to take actual measurements On-Site without any extra charges. Rev. 0:00/ I E-7

9 A I R D I S T R I B U T I O N S P E C I A L I S T GENERAL NOTES Pages onwards give performance data for all models and variants, and unless otherwise stated the following general notes apply: Throws shown are to three terminal velocity of 0.m/s, 0.m/s, 0.7m/s, (0fpm, 00fpm, 0fpm) with coanda effect across a flat ceiling, and with supply air at conditions with max DT=0k cooling. For standard room height of.7 metres, throws should be taken as the distance to the nearest wall (minimum plan dimension, MPD), or to half the distance between linear slot diffuser centres. 4 Care should be taken to avoid 'dumping' on cooling cycles is low jet velocities at the diffuser core. In order to avoid this it is advisable to ensure that neck velocities do not drop below 0.7m/s. The accoustical data were tested in accordance to ASHRAE standards, the octave band sound power levels obtained were plotted to determine the point of tangency with the highest rank Noise Criteria curve (NC) to establish the NC. Noise Criteria ratings were determined by subtracting room absorption of 0dB from the sound power level data. NC, and Pressure values shown, are based on a slot diffuser where the pattern control vanes were set for maximum horizontal throw for one of the test and positioned fully open for the vertical throw test. The hit and miss damper is aligned for a fully open position. The damper should only be used for fine balancing, as for every doubling of pressure there is a resulting increase in the noise level of +9dB for supply, or +db for exhaust. 7 The following tables include the results of tests conducted on samples of air terminals. The test results include Noise Criteria (NC), static pressure versus air flow, throw and effective area. Extrapolation was used to obtain the performance for other sizes and other parameters within the range of products mentioned above. Test method included in ETL report. ETL TEST REPORTS E-8 Rev. 0:00/

10 A I R D I S T R I B U T I O N S P E C I A L I S T PERFORMANCE DATA - SI UNITS SYMBOLS L/Sec :Air volume in litres per second. Af :Effective free area in square meters / per Lm. Vf :Face velocity in meters per second. Ak :Neck area in square meters / per Lm. Vk :Neck velocity in meters per second. Pt :Total pressure in pascal. Th :Throw in meters. NC :Noise Criteria. NOTES The large throw values are based on the minimum terminal velocity of 0. m/sec. The middle throw values are based on the medium terminal velocity of 0.0 m/sec. The small throw values are based on the maximum terminal velocity of 0.7 m/sec. CONDITIONS Supply or Return as indicated. Noise Criteria values are based on (0 db) room attenuation. Damper is fully open. Maximum room height = 4.0m Maximum T = 0K Notes: Rev. 0:00/ E-9

11 See notes on page E-9 A I R D I S T R I B U T I O N S P E C I A L I S T SUPPLY AIR SLOT DIFFUSER - SLSD HORIZONTAL SI-UNITS mm SLOT WIDTH 0 mm SLOT WIDTH mm SLOT WIDTH NO. OF AIR FLOW SLOTS (L/s) / LM EFFECTIVE EFFECTIVE EFFECTIVE Pt (Pa) NC Pt (Pa) NC Pt (Pa) NC AREA (m/lm) (0./0.0/0.7)m/s AREA (m/lm) (0./0.0/0.7)m/s AREA (m/lm) (0./0.0/0.7)m/s < < < < Rev. 0:00/ E-0

12 See notes on page E-9 A I R D I S T R I B U T I O N S P E C I A L I S T SUPPLY AIR SLOT DIFFUSER - SLSD VERTICAL SI-UNITS mm 0 mm mm NO OF AIR FLOW EFFECTIVE AREA EFFECTIVE EFFECTIVE SLOTS (L/s/LM) Pt (Pa) Thow (m) NC Pt (Pa) Thow (m) NC Pt (Pa) Thow (m) NC (m/lm) AREA (m/lm) AREA (m/lm) < 4.9 < < <.9 < < <. < < < 4.9 < < < 4 4. < < < 4. < < < Rev. 0:00/ E-

13 A I R D I S T R I B U T I O N S P E C I A L I S T RETURN AIR SLOT DIFFUSER - RLSD SI-UNITS mm SLOT WIDTH 0mm SLOT WIDTH mm SLOT WIDTH NO. OF SLOTS AIR FLOW (L/s) / LM Pt (Pa) NC Pt (Pa) NC Pt (Pa) NC See notes on page E-9 E- Rev. 0:00/

14 A I R D I S T R I B U T I O N S P E C I A L I S T PERFORMANCE DATA - IP UNITS SYMBOLS CFM :Air volume in cubic feet per minute. Af :Effective free area in square feet / per L.Ft. Vf :Face velocity in feet per minute. Ak :Neck area in square feet / per L.Ft. Vk :Neck velocity in feet per minute. Pt :Total pressure in inches water gauge. Th :Throw in feet NC :Noise Criteria. NOTES The large throw values are based on the minimum terminal velocity of 0 fpm. The middle throw values are based on the medium terminal velocity of 00 fpm. The small throw values are based on the maximum terminal velocity of 0 fpm. CONDITIONS Supply or Return as indicated. Noise Criteria values are based on (0 db) room attenuation. Damper is fully open. Maximum room height = 4.0m Maximum T = 0K Notes: Rev. 0:00/ E-

15 See notes on page E- A I R D I S T R I B U T I O N S P E C I A L I S T SUPPLY AIR SLOT DIFFUSER - SLSD HORIZONTAL IP-UNITS / SLOT WIDTH /4 SLOT WIDTH SLOT WIDTH NO. OF AIR FLOW SLOTS (CFM/LFT) EFFECTIVE Pt EFFECTIVE EFFECTIVE Pt Pt AREA (inwg) Terminal Velocity (SQ.FT./LFT) Terminal Velocity (SQ.FT./LFT) Terminal Velocity (0/00/0) fpm NC AREA (0/00/0) fpm NC AREA (0/00/0) fpm NC (in-wg) (in-wg) (SQ.FT./LFT) < < < < Rev. 0:00/ E-4

16 A I R D I S T R I B U T I O N S P E C I A L I S T SUPPLY AIR SLOT DIFFUSER - SLSD VERTICAL IP-UNITS / /4 NO OF AIR FLOW SLOTS (CFM/LFT) EFFECTIVE AREA EFFECTIVE AREA EFFECTIVE AREA Pt (in-wg) Thow (ft) NC Pt (in-wg) Thow (ft) NC Pt (in-wg) Thow (ft) NC (SQ.FT./LFT) (SQ.FT./LFT) (SQ.FT./LFT) < 0.07 < < < 0.00 < < < < < < 0.0 < < < < < < < < < See notes on page E- Rev. 0:00/ E-

17 A I R D I S T R I B U T I O N S P E C I A L I S T RETURN AIR SLOT DIFFUSER - RLSD IP-UNITS NO. OF SLOTS AIR FLOW (CFM / LFT) / SLOT WIDTH /4 SLOT WIDTH SLOT WIDTH Pt (in-wg) NC Pt (in-wg) NC Pt (in-wg) NC See notes on page E- E- Rev. 0:00/

for Pleasant & Healthy Air-Distribution ISO 9001:2000 Linear Slot Diffusers Product Bulletin 133-D

for Pleasant & Healthy Air-Distribution   ISO 9001:2000 Linear Slot Diffusers Product Bulletin 133-D for Pleasant & Healthy Air-Distribution ISO 9001:2000 Product Bulletin 133-D Linear Slot Diffusers Pleasant.. Serene.. YOU & DASCO... Since 1964 Partners for good health INTRODUCTION Linear slot diffusers

More information

HCD HIGH CAPACITY DRUM LOUVER

HCD HIGH CAPACITY DRUM LOUVER HIGH CAPACITY DRUM LOUVER The s (HCD) consist of extruded aluminum blades mounted inside a rotatable drum to produce long air throws with a high degree of directional control. Rotateable drum provides

More information

Supply air diffuser ROFB, RPFB

Supply air diffuser ROFB, RPFB Supply air diffuser ROFB, RPFB ROFB and RPFB are supply air diffusers with an integrated plenum box for freely suspended installation in a ceiling. The diffuser ROFB comes with an unperforated and RPFB

More information

Adjustable swirl diffuser ODZA TECHNICAL DATA

Adjustable swirl diffuser ODZA TECHNICAL DATA Adjustable swirl diffuser ODZA TECHNICAL DATA 2 Adjustable swirl diffuser ODZA Adjustable ceiling swirl diffuser ODZA is intended for commercial and industrial buildings with a large room volume and high

More information

CEILING DIFFUSERS technical CONTROL THE AIR YOU BREATHE. types -CD, CAB. Europair Africa a division of Performancair Products Africa (Pty) Ltd

CEILING DIFFUSERS technical CONTROL THE AIR YOU BREATHE. types -CD, CAB. Europair Africa a division of Performancair Products Africa (Pty) Ltd CEILING DIFFUSERS technical types -CD, CAB Europair Africa a division of Performancair Products Africa (Pty) Ltd tel +27 11 974 2425 fax +27 11 974 7251 web www.europair-africa.com email: info@europair-africa.com

More information

CLB 3 ATTRACTIVE JOINABLE LINEAR PROFILE EASILY ACCESIBLE VOLUME ADJUSTMENT INCLUDED FLEX CLAMP HEATING AND COOLING TERMINAL REHEAT AVAILABLE

CLB 3 ATTRACTIVE JOINABLE LINEAR PROFILE EASILY ACCESIBLE VOLUME ADJUSTMENT INCLUDED FLEX CLAMP HEATING AND COOLING TERMINAL REHEAT AVAILABLE CONSTANT VOLUME LINEAR BAR CEILING DIFFUSER CLB 3 ATTRACTIVE JOINABLE LINEAR PROFILE EASILY ACCESIBLE VOLUME ADJUSTMENT INCLUDED FLEX CLAMP HEATING AND COOLING TERMINAL REHEAT AVAILABLE CONTROL THE PERIMETER

More information

C O L M A N. Air Distribution SWIRL DIFFUSERS DRS SERIES DRS SERIES

C O L M A N. Air Distribution SWIRL DIFFUSERS DRS SERIES DRS SERIES C O L M N ir Distribution E N G I N E E R E D I R P R O D U C T S SWIRL DIFFUSERS DRS SERIES DRS SERIES D SERIES SWIRL DIFFUSERS pplication The DRS, DQS, DCS and DSS series of fixed circular swirl diffusers

More information

EXTRUDED ALUMINUM SQUARE AND RECTANGULAR DIFFUSERS

EXTRUDED ALUMINUM SQUARE AND RECTANGULAR DIFFUSERS INDUSTRIAL REGISTRATION NO.353 EXTRUDED ALUMINUM SQUARE AND RECTANGULAR DIFFUSERS SQUARE AND RECTANGULAR FLUSH CEILING DIFFUSERS OUTSTANDING FEATURES: Extruded aluminum construction 1-2-3-4 way throw patterns.

More information

CHILLED BEAM FLEXICOOL IQID

CHILLED BEAM FLEXICOOL IQID CHILLED BEAM FLEXICOOL IQID TECHNICAL CATALOGUE 2 Flexicool IQID Chilled beam - Technical catalogue CHILLED BEAM FLEXICOOL IQID The chilled beam Flexicool IQID is an integrated system for ventilation,

More information

for Asia / Pacific Radial outlet RA-N3... DS 4134 AUS /

for Asia / Pacific Radial outlet RA-N3... DS 4134 AUS / for Asia / Pacific Radial outlet RA-N... DS AUS./ Radial outlet RA-N Preliary remarks KRANTZ KOMPONENTEN radial outlets of type RA-N have fixed radial vanes. They generate high-quality, diffuse supply

More information

vento specification sheet

vento specification sheet type purpose application linear diffuser 18mm diffuser for air distribution for false ceiling the diffuser is used for the supply and exhaust of cooled or heated air in facilities such as offices, shopping

More information

GENERAL OVERVIEW GENERAL OVERVIEW

GENERAL OVERVIEW GENERAL OVERVIEW GENERAL OVERVIEW A GENERAL OVERVIEW Traditional HVAC systems in most commercial buildings today employ Overhead Mixing (Mixed Ventilation, MV) to meet both outdoor air ventilation and space conditioning

More information

Round duct nozzle jet diffuser Model DSA-RR

Round duct nozzle jet diffuser Model DSA-RR Round duct nozzle jet diffuser Model DSA-RR Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3

More information

Precision Duct Systems 4570 Commerce Cir SW Atlanta, GA Phone (404)

Precision Duct Systems 4570 Commerce Cir SW Atlanta, GA Phone (404) Project Name: Engineer: Contractor: Section Number: Date Submitted: Date Approved: Pressure Class: Material Type: Connections: 2005 Up to 10 wg 1995 2 wg pos 1995 4 wg pos 1995 10 wg 2005 neg WG: 1995

More information

Chilled beam iq Star WEGA II

Chilled beam iq Star WEGA II Chilled beam iq Star WEGA II Key features Ventilation Water Heating and cooling Adjustable induction Flow Pattern Control In option: Demand Controlled Ventilation, Pressure independent, Electrical heating,

More information

LindabPremum. Supply air beam. lindab we simplify construction

LindabPremum. Supply air beam. lindab we simplify construction lindab we simplify construction Lindab 03.2016 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems,

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary

More information

LindabPremax. Supply air beam. lindab we simplify construction

LindabPremax. Supply air beam. lindab we simplify construction lindab we simplify construction Lindab 03.2016 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems,

More information

CALMO

CALMO ---------------------------------------------------- Sound attenuator with recessed connection for rectangular ducts ---------------------------------------------------------------------- GENERAL is, due

More information

CADENZA

CADENZA ---------------------------------------------- ---------------------------------------------------------------------- Attenuator with aerodynamically shaped splitters for rectangular ducts GENERAL has

More information

Sizes JNŽ-6, ANŽ-3, ANŽ-4

Sizes JNŽ-6, ANŽ-3, ANŽ-4 JNŽ-6, ANŽ-3, ANŽ-4 Application are used in all kinds of low pressure air conditioning, air heating ind ventilation, where it is necesary to equalise the pressure between adjacent rooms. They can be applied

More information

Krantz Components. Multifunction Sail AVACS. Cooling and Heating Systems

Krantz Components. Multifunction Sail AVACS. Cooling and Heating Systems Multifunction Sail AVACS Cooling and Heating Systems 2 AVACS Air Ventilation And Cooling System 3 System design Air diffuser box Air connection Sound absorbers (optional) Cooling element with heat conducting

More information

IP65 Air Differential Pressure Switch

IP65 Air Differential Pressure Switch Page 1 of 5 PA-DPS-9x IP65 Air Differential Pressure Switch Features: Benefits: Close switching differential IP65 Housing Duct fixing kit included Switching point easily adjusted with scale in One screw

More information

Technical Documentation Linear diffusers series LDB

Technical Documentation Linear diffusers series LDB Technical Documentation Linear diffusers series 70435 Stuttgart, Grenzstraße 7, Germany Tel. +49 711 81-0, Fax +49 711 81-7 info@ltg-ag.de www.ltg-ag.com LTG Incorporated 105 Corporate Drive, Suite E Spartanburg

More information

SafidDampers. Class 1A & Class 1 Low Leakage Volume Control Damper ( Flange Type ) SPK Standard Construction. Description SPK

SafidDampers. Class 1A & Class 1 Low Leakage Volume Control Damper ( Flange Type ) SPK Standard Construction. Description SPK ( Flange Type ) SPK 30 400 Standard Construction FRAME: 60mm x 30mm x.5mm (6 Ga.) galvanized steel formed channel for flange connection. BLADES: 00mm, 5mm and 50mm wide airfoil shaped blades extruded aluminum.

More information

Air Differentail Pressure Switch

Air Differentail Pressure Switch Page 1 of 5 PA-DPS-8x Air Differentail Pressure Switch Features: Benefits: Close switching differential Duct fixing kit included Switching point easily adjusted with scale in Pascals Conduit entry can

More information

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted.

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted. SPECIFICATIONS - All material is solid brass with a #8 mirror finish unless otherwise noted. - All material sold by length is priced in one foot increments. ORDERING PROCEDURE - Use a Purchase Order number.

More information

Operating Instructions for Cobra and Lynx Duct Leakage Testers

Operating Instructions for Cobra and Lynx Duct Leakage Testers Operating Instructions for Cobra and Lynx Duct Leakage Testers Table of Contents Introduction Introduction... 2 Safety Precautions Safety Precautions.. 2 Prior to Testing System Preparation.. 4 Power Requirements...

More information

LindabSolus. Supply air beam. lindab we simplify construction

LindabSolus. Supply air beam. lindab we simplify construction lindab we simplify construction Lindab 03.2016 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems,

More information

Gripping rotary modules

Gripping rotary modules Gripping rotary modules Gripping rotary modules GRIPPING ROTARY MODULES Series Size Page Gripping rotary modules RP 314 RP 1212 318 RP 1216 322 RP 1520 326 RP 2120 330 RP 2128 334 RC 338 RC 1212 342 RC

More information

TABLE OF CONTENTS International Racquetball Federation officially approved specifications. Copyright 01/13/1983; rev.

TABLE OF CONTENTS International Racquetball Federation officially approved specifications. Copyright 01/13/1983; rev. Racquetball Court Specifications TABLE OF CONTENTS International Racquetball Federation officially approved specifications. Copyright 01/13/1983; rev. 1988; 1997, 2013 SECTION ONE: Performance and Specifications

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Pro-Form Direct Vent System

Pro-Form Direct Vent System The Pro-Form direct vent system has best in industry features that provide ease of installation, extreme durability and superior performance. The Pro-Form direct vent system is fully tested and listed

More information

LindabArchitect. Supply air beam

LindabArchitect. Supply air beam Lindab 01.2018 Lindab Ventilation. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems, product and product group designations

More information

Evolution. Radiant Panels. Radiant panel system LPHW up to 90 C Suspended ceiling grid or sofit mounting Vertical wall surface mounting

Evolution. Radiant Panels. Radiant panel system LPHW up to 90 C Suspended ceiling grid or sofit mounting Vertical wall surface mounting Evolution Radiant Panels Radiant panel system LPHW up to 90 C Suspended ceiling grid or sofit mounting Vertical wall surface mounting Contents IDENTIFICATION DESCRIPTION Page STYLE CG 3-7 STYLE CS, FC

More information

HVAC Air Duct Leakage. Tech University 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA

HVAC Air Duct Leakage. Tech University 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA HVAC Air Duct Leakage Tech University 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA Learning Objectives Understand the difference between System leakage and Duct leakage Understand

More information

Pressure decay sensor Pressure decay sensor Flow at 90 psi (6 bars) Tripping point at 90 psi (6 bar) supply Connection Mechanical life Relay C

Pressure decay sensor Pressure decay sensor Flow at 90 psi (6 bars) Tripping point at 90 psi (6 bar) supply Connection Mechanical life Relay C Position Detectors Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com / Pressure decay sensor Pressure decay sensor 8 04 02 Flow at 90 psi (6 bars) Tripping point at 90 psi

More information

Appendix A. Luminaire Schedule and Cutsheets

Appendix A. Luminaire Schedule and Cutsheets Appendix A Luminaire Schedule and Cutsheets Page 1 of 79 Tag Luminaire Manufacturer Description Catalog No. Mounting No. Alfa Gemini fully adjustable, directional track head with G26 bronze, mesh metal

More information

MANUAL. Verkstadsvagen 2, SE SKELLEFTEA, Sweden Tel , Fax P17W45_MPREX_F_EN

MANUAL. Verkstadsvagen 2, SE SKELLEFTEA, Sweden Tel , Fax P17W45_MPREX_F_EN MANUAL Verkstadsvagen 2, SE 931 61 SKELLEFTEA, Sweden Tel. +46 910-361 80, Fax. +46 910-130 22 www.fumex.com info@fumex.se P17W45_MPREX_F_EN Contents Important information 3 Applications 3 Technical data

More information

AIR DIFFUSION INDUCTIVE MICRO-PERFORATED DUCTS

AIR DIFFUSION INDUCTIVE MICRO-PERFORATED DUCTS cop1 SISTEMI INNOVATIVI TRATTAMENTO ARIA AMBIENTE AIR DIFFUSION INDUCTIVE MICRO-PERFORATED DUCTS SELECTION CATALOGUE JULY 2012 EDITION INTRODUCTION The DLD air diffusion perforated ducts are born with

More information

BULLETIN FA-300. February 1999 AXIAD II. Adjustable Pitch Airfoil Axial Flow Fan

BULLETIN FA-300. February 1999 AXIAD II. Adjustable Pitch Airfoil Axial Flow Fan BULLETIN FA-300 February 1999 AXIAD II Adjustable Pitch Airfoil Axial Flow Fan AXIAD II The axial flow fan with: High efficiency Low sound level Adjustable pitch blades Complete range of accessories Axial

More information

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS

K13.12 FACE FIXED PANIC EXIT DEVICE K13 DOORS K13 DOORS K13.12 FACE FIXED PANIC EXIT DEVICE 01.03.2018 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. Base set n

More information

Ramp Hand-railing System. Complies with Building Regulations. Lockinex. ea i, ea u i

Ramp Hand-railing System. Complies with Building Regulations. Lockinex. ea i, ea u i Ramp Hand-railing System Complies with Building Regulations Lockinex ea i, ea u i INTRODUCTION COMPOSITION, MANUFACTURE Handrails to ramps must comply to current building regulations. The Lockinex system

More information

Statesville, NC. Results of AM ASHRAE 110 Laboratory Fume Hood Performance Evaluations Venturi Hood

Statesville, NC. Results of AM ASHRAE 110 Laboratory Fume Hood Performance Evaluations Venturi Hood Statesville, NC Results of AM ASHRAE 11 Laboratory Fume Hood Performance Evaluations Venturi Hood January, 217 Prepared By: Exposure Control Technologies Inc. 231-C East Johnson Street Cary, NC 27513 Phone:

More information

Mechanical Wind Recorder

Mechanical Wind Recorder THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021186/11/06 Mechanical Wind Recorder 4.3900.20.000 ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083

More information

APPENDIX A SAMPLE FHT SPECIFICATION (This recommended FHT specification is available from

APPENDIX A SAMPLE FHT SPECIFICATION (This recommended FHT specification is available from SAMPLE FHT SPECIFICATION (This recommended FHT specification is available from www.nebb.org) NEBB recommends that these FHT Specifications be referenced as related documents in other appropriate sections

More information

VA40 - VA45 Technical Datasheet

VA40 - VA45 Technical Datasheet VA40 - VA45 Technical Datasheet Variable area flowmeter Local indication without auxiliary power Adaptable to meet customers' requirements Replaceable mounting parts KROHNE CONTENTS VA40 - VA45 1 Product

More information

Use of Correction Factors When Commissioning Air Systems

Use of Correction Factors When Commissioning Air Systems Shaun Matthews G5 Thesis 24 th January 2016 Rev. 2 Use of Correction Factors When Commissioning Air Systems S. Matthews Grade 5 Thesis - Use Of Correction Factors Rev. 2 1 of 12 Contents Introduction What

More information

Channel Bracket Support Cable Bracket Bearer Locking Pin Foundation Bolt Iron Anchor Step Manhole Sump Grill PVC/Steel Ladder Ladder Support & Hook

Channel Bracket Support Cable Bracket Bearer Locking Pin Foundation Bolt Iron Anchor Step Manhole Sump Grill PVC/Steel Ladder Ladder Support & Hook Manhole Accessories Channel Bracket Support Cable Bracket Bearer Locking Pin Foundation Bolt Iron Anchor Step Manhole Sump Grill PVC/Steel Ladder Ladder Support & Hook Manhole Guard Lifter Manhole Ventilator

More information

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar Pressure Reducing Valve DMV 755 set range:,0-9,0 bar Advantage pressure setting possible at any time, also during operation high reproducibility of the set pressure high level of operating safety and long

More information

EDGE SERIES PRICE LIST. June 1st, 2017 Edition I1I

EDGE SERIES PRICE LIST. June 1st, 2017 Edition I1I EDGE SERIES PRICE LIST June 1st, 2017 Edition I1I EDGE SERIES F R A M E L E S S PA N E L S Desk Dividers FEATURES Symmetry Office EDGE Series Panels offer the adaptability of the Terrace Panel without

More information

Mini Channel & Fittings

Mini Channel & Fittings Our mini channels and fittings provide for an economical method of supporting light load requirements on a strut system. Channel Channels are cold formed on our modern rolling mills from 18 Ga. (1.2 mm)

More information

FMU4X, FMC4X FMU4P, FMC4P

FMU4X, FMC4X FMU4P, FMC4P ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal

More information

CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division

CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division 5023 HAZEL JONES ROAD, BOSSIER CITY, LA 71111 888.315.1561 800.877.8746 FAX SALES@GORDONCLEANROOM.COM GORDONCLEANROOM.COM AN EMPLOYEE OWNED COMPANY CLEANROOM GEL GRID CEILING SYSTEM PRODUCT DATA Division

More information

Digital Flow Switch. Series PFM7

Digital Flow Switch. Series PFM7 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow

More information

PROVIDING QUALITY SOLUTIONS FOR THE AUDIOMETRIC INDUSTRY

PROVIDING QUALITY SOLUTIONS FOR THE AUDIOMETRIC INDUSTRY PROVIDING QUALITY SOLUTIONS FOR THE AUDIOMETRIC INDUSTRY PRODUCT OPTIONS AMB Portable Series: Booths consist of 2 or 3 inch panels with integrated ventilation in the roof and floor. AMB 410: Consists

More information

RCP5W-RA Series. www. r o b o c y lind e r. d e. Dust-/Splash-/Water-proof RoboCylinder Rod Type with Battery-less Absolute Encoder

RCP5W-RA Series. www. r o b o c y lind e r. d e. Dust-/Splash-/Water-proof RoboCylinder Rod Type with Battery-less Absolute Encoder Product Data Sheets RCPW-RA RoboCylinder Brochure Extract GB Dust-/Splash-/Water-proof RoboCylinder Rod with Battery-less Absolute Encoder RCPW-RA Series www. r o b o c y lind e r. d e Specification Table

More information

General Information Gravity roller conveyors are available in many sizes and configurations as shown on the following pages. There are many factors to consider when selecting a gravity conveyor. The following

More information

Pressure reducing valves Index

Pressure reducing valves Index Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel

More information

DESIGN OF AN EFFECTIVE LOW PRESSURE VAV AIR DISTRIBUTION SYSTEM

DESIGN OF AN EFFECTIVE LOW PRESSURE VAV AIR DISTRIBUTION SYSTEM ABSTRACT The aim of this paper is to provide the air conditioning engineer with a clear set of guidelines for use in the design of the air distribution system for a low pressure Variable Air Volume system.

More information

Printview: End and intermediate plate; 1 mm thick - Item No.:

Printview: End and intermediate plate; 1 mm thick - Item No.: Printview: End and intermediate plate; mm thick - Item No: 89-2 End and intermediate plate; mm thick Item No: 89-2 End and intermediate plate; mm thick Marking Business data Supplier WAGO Item no 89-2

More information

Air-service devices, Series MU1

Air-service devices, Series MU1 Electric Drives and Controls Hydralics Linear Motion and Assembly Technologies Pneumatics Service Air-service devices, Series MU1 Technical data Pressure regulator valve, MU1, G 1 Technical Data Type Operating

More information

Electro Controls. Level WattsIndustries.co.uk

Electro Controls. Level WattsIndustries.co.uk Electro Controls Level - 2017 WattsIndustries.co.uk levels Section 19 LIQUID LEVEL SWITCHES HORIZONTAL ELL.. Volt free contacts To monitor liquid level in tanks and switch pumps or an alarm in the event

More information

CLEAN-PROTECT Emergency Gas Release Absorber Models: CP500SF, CS1000SF

CLEAN-PROTECT Emergency Gas Release Absorber Models: CP500SF, CS1000SF CLEAN-PROTECT Emergency Gas Release Absorber Models: CP500SF, CS1000SF Controlled product information. Intended use: technical reference for quotations and similar customer projects. Not intended for general

More information

Slide and Turn System SF35

Slide and Turn System SF35 Profile system Framed slide and turn system Non-thermally insulated aluminum profiles with insulated glass Option of flush or weathered bottom track The flush bottom track is particularly suitable for

More information

EZ SERIES FIXED ACCESS LADDERS

EZ SERIES FIXED ACCESS LADDERS EZ SERIES FIXED ACCESS LADDERS Engineered from the ground up for OSHA 1910.3 COMPLIANCE Installs in three easy steps 1 ATTACH MOUNTING BRACKETS PLACE RUNG IN BRACKET 3 SECURE WITH BOLTON CAPTURE PLATE

More information

Parts Manual. Scraper Hitches PH:

Parts Manual. Scraper Hitches PH: Parts Manual Scraper Hitches 12-18 1 Table of Contents A123299 Swivel Hitch 3 A1063527 Super Swivel Hitch 4 A125056 Yoke Hitch 5 A125057 Super Capacity Hitch 6 A125223 MDU Hitch 7 A123224 360 Swivel Hitch

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

Rolled Rotary Ball Screw

Rolled Rotary Ball Screw 51E Rolled Rotary Ball Screw Model BLR End cap Collar Seal Spacer Ball End cap Screw shaft Outer ring Ball screw nut Retainer Outer ring Ball Fig.1 Structure of Large Lead Rotary Nut Ball Screw Model BLR

More information

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing

Extension Platform. Base Platform. Crossover. Exit railing. Exit Railing Base Platform Galvanized With metal grate and two brackets Railing on the long side and a face side Extension Platform Galvanized With metal grate and one bracket Railing on the long side with rail connection

More information

DICTATOR Spring Rope Pulleys for the Closing of Sliding Doors

DICTATOR Spring Rope Pulleys for the Closing of Sliding Doors DICTATOR for the Closing of Sliding Doors Spring rope pulleys are a simple, efficient and cost-effective closing device for sliding doors. During the opening of the door the internal spring is tensioned

More information

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9 Auto Feed Lube, Auto Feed Tank 00 to 900, -/-9 Standard Specifications Fluid Proof pressure Operating pressure differential range (Difference between tank pressure and line pressure) Vibration resistance

More information

A17W23_MASE_MUS_EN MANUAL

A17W23_MASE_MUS_EN MANUAL A1W2_MASE_MUS_EN MANUAL CONTENTS 1 Identification 1.1 Manufacturer 1.2 Product name 1. Year of manufacture 1. Area of use 2 Technical specification 2.1 Design 2.2 Function 2. Technical data 2. Security

More information

Integral type Differential pressure flowmeter VNT Series

Integral type Differential pressure flowmeter VNT Series Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in

More information

MultiWoody design Mario Cucinella

MultiWoody design Mario Cucinella design Mario Cucinella 9000 7000 5000 MaxiWoody ø 260 MaxiWoody ø 315 MaxiWoody ø 380 www.iguzzini.com 473 Compositions Flanges and supports for 2 floodligts single flange double flange for 3 floodligts

More information

Owner s Manual Installation and Operation

Owner s Manual Installation and Operation Owner s Manual Installation and Operation Models: RED40-N-AU RED40ST-N-AU Ref No: GMK10107 AS4553:2008 Important operating and maintenance instructions included. NOTICE DO NOT DISCARD THIS MANUAL Read,

More information

Automatic extractor outlet

Automatic extractor outlet L-07-2-01e Automatic extractor outlet Type HFA Contents Application Realisation Operation Safety instructions Contents Application Realisation Operation Safety instructions 2 Connection diagram Dimensions

More information

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Limit switches OsiSense XC Special For material handling applications, type XC1 AC Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics

More information

ATHLETICS Track & Field Equipment

ATHLETICS Track & Field Equipment ATHLETICS Track & Field Equipment Aluminium Curbing Order No. 11260 The aluminium curbing is made from special made anodized aluminium profiles. It is a mobile marker and separator of the running track.

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios

Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios Sizing of extraction ventilation system and air leakage calculations for SR99 tunnel fire scenarios Yunlong (Jason) Liu, PhD, PE HNTB Corporation Sean Cassady, FPE HNTB Corporation Abstract Extraction

More information

Centriflow Plus High-pressure plug fan - Technical Data

Centriflow Plus High-pressure plug fan - Technical Data Centriflow Plus 3 High-pressure plug fan - Technical Data Contents General description...3 General survey chart...4 Design description Fan Impeller...5 Fan Inlet...5 base with base frame...5 Hub...5 Air

More information

REPORT NUMBER: G COQ-004 rev 1 ORIGINAL ISSUE DATE: May 18, 2010 REVISION DATE: June 7, 2010

REPORT NUMBER: G COQ-004 rev 1 ORIGINAL ISSUE DATE: May 18, 2010 REVISION DATE: June 7, 2010 TEST REPORT REPORT NUMBER: G100017878COQ-004 rev 1 ORIGINAL ISSUE DATE: May 18, 2010 REVISION DATE: June 7, 2010 EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C.

More information

Finvector Perimeter Heating

Finvector Perimeter Heating Finvector Perimeter Heating Products that perform... By people who care Identification Contents Page Identification 2 Introduction 2 Authority 2 Description 3-6 Range 2 Casings 3 Elements 3 Introduction

More information

VISUAL AIDS FOR DENOTING OBSTACLES

VISUAL AIDS FOR DENOTING OBSTACLES CHAPTER 6. VISUAL AIDS FOR DENOTING OBSTACLES 6.1 Objects to be marked and/or lighted Note. The marking and/or lighting of obstacles is intended to reduce hazards to aircraft by indicating the presence

More information

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments ARCA cabinet NEW High performance polycarbonate cabinet Protection in demanding environments NEW Fibox ARCA Fibox ARCA non corrosive electrical cabinets for use in extremely harsh and demanding environments

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic

More information

Liquid level instruments BM 24 /BM 51

Liquid level instruments BM 24 /BM 51 KROHNE 09/2001 7.02362.21.00 GR/PRINTO Liquid level instruments / Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Armatures for analytical probes

Armatures for analytical probes Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type

More information

Compact pressure switches for gas and air

Compact pressure switches for gas and air Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The

More information

Barcol-Air BRM Radiant Module

Barcol-Air BRM Radiant Module Barcol-Air BRM Radiant Module General The high capacity Radiant Cooling Module BRM is based on the principles of the radiant cooling technology. Due to the purpose designed profile and the geometry of

More information

Installation and Operation Manual

Installation and Operation Manual Manual Static pressure transducer with controller Differential static pressure transducer with analog output and optional PI control mode Large diaphragm element with differential transformer Transducer

More information

Mott Manufacturing Limited

Mott Manufacturing Limited Mott Manufacturing Limited 452 Hardy Road, Brantford, Ontario, Canada, N3T 5L8. Telephone: 519-752-7825 Fax: 519-752-2895 Web Site: www.mott.ca Fume Hood Performance Test Test Date: 9-Sep-08 Model Number:

More information

M2 Antenna Systems, Inc. Model No: VLP16

M2 Antenna Systems, Inc. Model No: VLP16 M2 Antenna Systems, Inc. Model No: 100-600VLP16 SPECIFICATIONS: Model... 100-600VLP16 Frequency Range... 100-600 MHz Cont. *Gain... 9.64 dbi Front to back... 12 db Typical Beamwidth... E=64 / H=70 Feed

More information

Datasheet liniled Handrail 42.4 V1017 IK10. F RoHS FROST CLEANING AGENTS RESISTANT UV RESISTANT

Datasheet liniled Handrail 42.4 V1017 IK10. F RoHS FROST CLEANING AGENTS RESISTANT UV RESISTANT Datasheet liniled Handrail 42.4 V1017 F RoHS IP40 IP68 IK10 AISI 316 UV RESISTANT FROST CLEANING AGENTS RESISTANT Handrail 42.4 Product information Technical specifications Product specifcations Required

More information

MEDAP-MOBILE GAS SUPPLY

MEDAP-MOBILE GAS SUPPLY MEDAP-MOBILE GAS SUPPLY This document is intended to provide information to an international audience outside of the US. MOBILE GAS SUPPLY 3 MOBILE GAS SUPPLY FOR TRANSPORTATION AND WARD PRESSURE REGULATORS,

More information

Layout Guidelines. Overview

Layout Guidelines. Overview TECHNICA RESOURCES ayout Guidelines Included are the design layout guidelines for evaporative cooling products in several situations typically encountered by designers. These guidelines represent minimum

More information