The Pennsylvania State University Energized Electrical Safety Program

Size: px
Start display at page:

Download "The Pennsylvania State University Energized Electrical Safety Program"

Transcription

1 Introduction: The Pennsylvania State University Energized Electrical Safety Program Purpose: Electricity is a serious workplace hazard, capable of causing both employee injury and property damage. It is the policy of the Pennsylvania State University (PSU) to protect all employees, students, and other personnel from potential electrical hazards. This will be accomplished through compliance with the work practices described herein along with effective application of engineering controls, administrative controls, and the use of personal protective equipment. The PSU electrical safety program is founded on the principle of avoiding energized work unless it is absolutely necessary. Live parts will be deenergized before an employee works on or near them unless one of the following conditions applies: Deenergizing introduces additional or increased hazards. Examples of additional or increased hazards would include interruption of life support equipment, deactivation of emergency alarm systems, or shutdown of hazardous location ventilation systems. Deenergizing is not possible due to equipment design or operational limitations. Examples of this situation would include testing of electrical circuits that can only be performed with the circuit energized and work on circuits that form an integral part of a continuous process that would otherwise need to be completely shut down in order to permit work on one circuit or piece of equipment. Live parts are operating at less than 50 volts to ground and there is no increased exposure to electrical burns or to explosion due to electrical arcs. Live parts are to be deenergized in accordance with the PSU Lockout/Tagout Program. If live parts are not placed in an electrically safe condition, the work practices described in this document must be used to protect employees. This program has been established in order to: Ensure the safety of employees who may work on or near electrical systems. Ensure that work units understand and comply with safety standards related to electrical work. Ensure that work units follow uniform practices during the completion of electrical work. Scope & Applicability: This program applies to all Penn State properties and work performed by Penn State employees regardless of job site location. The Hershey Medical Center and the College of Medicine are exempt from this program. Page 1 of 30

2 Table of Contents 1.0 References 2.0 Responsibilities 3.0 Definitions 4.0 Training 5.0 Working On or Near Live Parts 5.1 Energized electrical work permit 5.2 Testing, troubleshooting and voltage measuring 5.3 Approach boundaries to live parts 5.4 Other precautions for personnel activities 6.0 Personal Protective Equipment 6.1 General requirements 6.2 Flash protection boundary 6.3 Flame-resistant apparel & underlayers 6.4 Rubber insulating equipment 7.0 Insulated Tools & Equipment 8.0 Labeling 9.0 Alerting Techniques 10.0 Contract Employees Appendix A: Appendix B: Appendix C: Appendix D: Appendix E: Appendix F: Appendix G: Appendix H: Energized Electrical Work Permit Approach Boundaries to Live Parts for Shock Protection Hazard/Risk Category Classifications Protective Clothing and Personal Protective Equipment Matrix PPE for Common Electrical Work Tasks at PSU Work Unit PPE Requirements for Energized Tasks Inspection Schedule for Rubber Insulating Equipment Arc Flash Warning Label (Example) Page 2 of 30

3 1.0 References: The following documents were used as references when developing this program: NFPA 70E, Standard for Electrical Safety in the Workplace, 2009 edition OSHA 29 CFR through , Electrical Safety-Related Work Practices Pennsylvania State University Lockout/Tagout Program- SY Responsibilities: 2.1 Budget Executives and Budget Administrators Ensure that responsibilities assigned within this program are carried out within their administrative work unit. Designate individuals responsible for the implementation of the electrical safety program within their work unit. Actively support this program as part of the work unit s overall safety effort. 2.2 Environmental Health and Safety Department Assist work units in implementing the provisions of this program. Periodically review and update this written program. Provide or coordinate general training for work units on the content of this program. Evaluate the overall effectiveness of the electrical safety program on a periodic basis. Serve as chair of PSU Electrical Safety Committee. 2.3 Safety Officers Determine the applicability of the electrical safety program to activities conducted within their work unit. Coordinate implementation of the electrical safety program within the work unit. Assist in the investigation of all injuries and incident involving electrical work. Ensure that the records outlined in section 4.0 of this program are maintained for their work unit. 2.4 Supervisors Ensure employees comply with all provisions of the electrical safety program. Ensure that electrical equipment is labeled with appropriate arc flash warning labels. Ensure employees receive training appropriate to their assigned electrical tasks and maintain documentation of such training. Page 3 of 30

4 Develop and maintain a listing of all qualified employees under their supervision. Ensure employees are provided with and use appropriate protective equipment. 2.5 Employees Follow the work practices described in this document, including the use of appropriate protective equipment and completion of pre-use inspections. Attend all training required relative to this program. Immediately report any concerns related to electrical safety to supervision. 2.6 OPP Electrical Engineering Complete calculations required by this program when needed. Place an emphasis on controlling electrical hazards through the application of engineering and design controls. 2.7 PSU Electrical Safety Committee Meet on a periodic basis to review electrical safety issues at PSU. Review all energized electrical work permits submitted for approval. Promote consistency in how electrical tasks are completed within the various work units of PSU. 3.0 Definitions: The following terms are defined in order to allow a better understanding of this program: Arc rating: The maximum incident energy resistance demonstrated by a material (or a layered system of materials) prior to breaking open or at the onset of a second-degree skin burn. This rating is assigned to electrical protective clothing and is normally expressed in calories per square centimeter (cal/cm 2 ). Electrically safe work condition: A state in which the conductor or circuit part to be worked on or near has been disconnected from energized parts, locked/tagged in accordance with PSU policy, tested to ensure the absence of voltage, and grounded if determined necessary. Energized: Electrically connected to or having a source of voltage. Exposed (as applied to live parts): Capable of being inadvertently touched or approached from closer than a safe distance by a person. It is applied to parts that are not suitably guarded, isolated, or insulated. Flash hazard analysis: A study investigating a worker s potential exposure to arc-flash energy, conducted for the purpose of injury prevention and the determination of safe work practices along with appropriate levels of PPE. Flash protection boundary: An approach limit at a distance from exposed live parts within which a person could receive a second degree burn if an electrical arc flash were to occur. Page 4 of 30

5 4.0 Training: PSU Energized Electrical Safety Program Flash suit: A complete FR clothing and equipment system that covers the entire body, except for the hands and feet. (Such a suit typically includes pants, jacket, and a bee-keeper style hood fitted with a face shield). FR apparel: Flame-resistant apparel; describes a broad category of clothing designed to protect employees from electrical arc events during completion of energized tasks. Incident energy: The amount of energy impressed on a surface, a certain distance from the source, generated during an electrical arc event. One of the units used to measure incident energy is calories per square centimeter (cal/cm 2 ). Limited approach boundary: An approach limit at a distance from an exposed live part within which a shock hazard exists. Live parts: Energized conductive components. Prohibited approach boundary: An approach limit at a distance from an exposed live part within which work is considered the same as making contact with the live part. An acronym for Personal Protective Equipment. Qualified person: One who has skills and knowledge related to the construction and operation of the electrical equipment and installation and has received training on the hazards involved. Restricted approach boundary: An approach limit at a distance from an exposed live part within which there is an increased risk of shock (due to electrical arc-over combined with inadvertent movement) for personnel working in close proximity to the live part. Testing and Troubleshooting: Process of analyzing the operation of a faulty piece of electrical equipment/circuit in order to determine why it is not functioning normally. The multimeter is a commonly used piece of testing equipment used to measure voltage and resistance. As soon as tools such as a screwdriver, wrench, pliers, etc are used on or near a live circuit, the task is no longer considered testing and troubleshooting. Unqualified person: Any person who does not meet the definition of a qualified person. Working near (live parts): Any activity within a Limited Approach Boundary. Working on (live parts): Coming in contact with live parts via tools, probes, test equipment, hands, feet, or other body parts regardless of the level of PPE worn. There are two categories of working on : Diagnostic (testing) is taking readings or measurements of electrical equipment with approved test equipment that does not require making any physical change to the equipment; repair is any physical alteration of electrical equipment (such as making or tightening connections, removing or replacing components, etc.) 4.1 Employees who are exposed to an electrical hazard that is not reduced to a safe level by the installation (panel cover, outlet cover, etc) must be trained. Page 5 of 30

6 4.2 Training must be provided before the employee is assigned duties that involve work near or on electrical systems. 4.3 The level of electrical safety training provided is dependent on whether the employee is classified as a qualified person or unqualified person. 4.4 A qualified person shall be trained and knowledgeable in all of the following topics: 1.) Construction and operation of equipment on which work is assigned. 2.) Skills and techniques necessary to distinguish exposed energized parts from other parts of electrical equipment. 3.) Skills and techniques necessary to determine the nominal voltage of exposed live parts. An individual can obtain knowledge in the three topics listed above through a combination of methods including the individual s education, electric license, past work experience, and on-the-job training. 4.) The approach distances specified in this document and the corresponding voltages to which the qualified employee will be exposed. 5.) The process necessary to determine the degree and extent of electrical hazards along with the PPE and job planning necessary to perform the task safely. An individual must attend an NFPA 70E training session approved by EHS to obtain the required knowledge of the two topics listed above. 4.5 A person can be considered qualified with respect to certain equipment and methods but unqualified for others. 4.6 An unqualified person shall be trained in the inherent hazards of electricity and any related work practices that are necessary for their safety. 4.7 Each work unit shall maintain a record of all electrical training provided to their employees along with a listing of all employees classified as qualified persons. 5.0 Working On or Near Live Parts: 5.1 Energized Electrical Work Permit: If live parts are not placed in an electrically safe condition, work to be performed shall be considered energized electrical work and will be performed by written permit only A copy of the PSU Energized Electrical Work Permit can be found in Appendix A of this document. The intent of this permit is to ensure that all appropriate safety precautions are taken prior to starting energized electrical work. Page 6 of 30

7 5.1.3 The permit is to be originated by the individual requesting that the energized work be completed. The requestor is responsible for completing Section I of the permit. o The requestor will normally be the supervisor of the employees who will be completing the work. o The requestor may also be an individual from a work unit where the work is to be completed. If this is the case, Section I of the permit must be completed by a unit administrator The qualified persons completing the task are responsible for completing Section II of the permit Members of the PSU Electrical Safety Committee must approve the permit prior to commencing work. An approval signature must be obtained from one committee member within each of the following three groups: OPP Electrical Engineer Member of EHS Safety Officer of Work Unit (if at University Park) or Commonwealth Services Representative (if at a campus location) A job briefing is required before the start of each job involving energized electrical work. Each qualified person shall be briefed on the job. At a minimum the briefing must include the following: associated electrical hazards, work procedures, special precautions, isolation points and procedures, emergency response, PPE requirements, and other work in the immediate area The permit must be posted in the area where the energized work is taking place for the duration of the task At least two qualified employees must be present for all energized work requiring a permit If both qualified employees are working on the circuit, an attendant is required to control any unqualified person from entering the limited approach boundary. The attendant can be an unqualified person as long as he or she remains outside the limited approach boundary Copies of all energized electrical work permits must be provided to both the work unit Safety Officer and the EHS Department upon completion of the task. Page 7 of 30

8 5.2 Testing, Troubleshooting, and Voltage Measuring PSU Energized Electrical Safety Program Work related to testing, troubleshooting, and voltage measuring may be completed without an energized electrical permit provided appropriate safe work practices and PPE are used. 5.3 Approach Boundaries to Live Parts: Observing a safe approach distance from exposed energized parts is an effective means of maintaining electrical safety. As the distance between an individual and live parts increases, the potential for an electrical injury decreases Safe approach distances will be determined for all tasks in which approaching personnel are exposed to live parts Safe approach distances to fixed live parts can be determined by referring to Appendix B, Approach Boundaries to Live Parts for Shock Protection. This appendix can be used to identify the Limited, Restricted, and Prohibited Approach Boundaries associated with various system voltages Unqualified persons may only cross the Limited Approach Boundary when they are under the direct supervision of a qualified person Qualified persons may not cross or take any conductive object closer than the Restricted Approach Boundary unless one of the following conditions applies: The qualified person is insulated or guarded from the live parts and no uninsulated part of the qualified person s body crosses the Prohibited Approach Boundary. The live parts are insulated from the qualified person and from any other conductive object at a different potential Crossing the Prohibited Approach Boundary is considered the same as making contact with energized parts. Qualified persons may only cross this boundary when all of the following precautions have been taken: The qualified person has specific training to work on energized parts. The qualified person has obtained an approved Energized Electrical Work Permit. Page 8 of 30

9 The qualified person uses PPE appropriate for working on energized parts which is rated for the voltage and energy level involved. 5.4 Other Precautions for Personnel Activities: Employees shall not reach blindly into areas that might contain exposed live parts Employees shall not enter spaces containing live parts unless illumination is provided that allows the work to be performed safely Conductive articles of jewelry and clothing (such as watchbands, bracelets, rings, key chains, necklaces, metalized aprons, cloth with conductive thread, metal headgear, or metal frame glasses) shall not be worn where they present an electrical contact hazard with exposed live parts Conductive materials, tools, and equipment that are in contact with any part of an employee s body shall be handled in a manner that prevents accidental contact with live parts. Such materials and equipment include, but are not limited to, long conductive objects such as ducts, pipes, tubes, conductive hose and rope, metal-lined rules and scales, steel tapes, pulling lines, metal scaffold parts, structural members, and chains When an employee works in a confined space or enclosed space (such as a manhole or vault) that contains exposed live parts, the employee shall use protective shields, barriers, or insulating materials as necessary to avoid contact with these parts. Doors, hinged panels, and the like shall be secured to prevent them from swinging into employees. 6.0 Personal Protective Equipment: 6.1 General Requirements Employees working in areas where electrical hazards are present shall be provided with, and shall use, protective equipment that is designed and constructed for the specific body part to be protected and for the work to be performed Work units will provide electrical protective equipment required by this program at no cost to employees, such as FR apparel, eye protection, head protection, hand protection, insulated footwear, and Page 9 of 30

10 face shields. Work units are not responsible for providing non-fr underlayers to employees All protective equipment shall be maintained in a safe, reliable condition by the employee to whom it is issued Employees shall wear nonconductive head protection whenever there is a danger of head injury from electric shock or burns due to contact with live parts or from flying objects resulting from an electrical explosion Employees shall wear nonconductive protection for the face, neck, and chin whenever there is danger of injury from exposure to electric arcs or flashes or from flying objects resulting from an electrical explosion Employees shall wear protective equipment for the eyes whenever there is a danger of injury from electric arcs, flashes, or from flying objects resulting from an electrical explosion Employees shall wear rubber insulating gloves where there is danger of hand and arm injury due to contact with live parts or possible exposure to arc flash burn. The following ratings can be found on voltage rated gloves: Class 00 = Protect against voltage up to 500 volts Class 0 = Protect against voltage up to 1,000 volts Class 1 = Protect against voltage up to 7,500 volts Class 2 = Protect against voltage up to 17,000 volts Class 3 = Protect against voltage up to 26,500 volts Class 4 = Protect against voltage up to 36,000 volts Where insulated footwear is used as protection against step and touch potential, dielectric overshoes shall be required. Insulated footwear shall not be used as the primary protection. The integrity of the insulating quality of such footwear cannot be established easily after the worker has been wearing them in the working environment Face shields without an arc rating will not be used for electrical work. Safety glasses or goggles must always be worn underneath face shields Additional illumination may be needed when using tinted face shields as protection during electrical work Employees shall wear hearing protection whenever there is a danger of noise overexposure resulting from an electrical explosion. Page 10 of 30

11 6.2 Flash Protection Boundary Personal protective equipment shall be provided to and used by all employees working within the Flash Protection Boundary For systems that are 600 volts or less, the Flash Protection Boundary shall be a minimum of four feet, based on the product of clearing time of 2 cycles (0.033 sec) and the available bolted fault current of 50 KA or any combination not exceeding 100 ka cycles (1667 ampere seconds). The Flash Protection Boundary for systems under 600 volts may also be calculated through engineering analysis using Annex D of NFPA 70E (2009 edition) For systems that are above 600 volts, the Flash Protection Boundary shall be determined through engineering analysis The specific protective equipment to be worn within the Flash Protection Boundary can be determined by one of the following three methods: (1) Complete a detailed flash hazard analysis under engineering supervision that determines the incident exposure energy of each employee. Appropriate protective clothing can then be selected based on the calculated exposure level. Criteria for completing such an analysis can be obtained from the EHS Department. (2) Determine the hazard level of the task by referring to NFPA 70E Table (C) (9), Hazard/Risk Category Classifications (Appendix C of this document). This table also indicates whether voltage-rated gloves and/or voltage-rated tools need to be used. Once the hazard level of the task has been determined, the required PPE can then be ascertained from NFPA 70E Table (C) (10), Protective Clothing and PPE Matrix. (Appendix D of this document). (3) Refer to Appendix E of this document to determine the necessary PPE for a given task. This appendix defines the PPE requirements for common electrical tasks based on the information contained in Appendices C and D Each work unit shall develop and maintain a listing of the specific PPE requirements for each energized electrical task conducted by their employees using the form found in Appendix F of this document. Page 11 of 30

12 6.3 Flame-Resistant Apparel & Underlayers PSU Energized Electrical Safety Program FR apparel shall be visually inspected before each use. FR apparel that is contaminated or damaged shall not be used. Protective items that become contaminated with grease, oil, flammable liquids, or combustible liquids shall not be used The garment manufacturer s instructions for care and maintenance of FR apparel shall be followed When FR apparel is worn to protect an employee, it shall cover all ignitable clothing and allow for movement and visibility FR apparel must cover potentially exposed areas as completely as possible. FR shirt sleeves must be fastened and FR shirts/jackets must be closed at the neck Non-melting, flammable garments (i.e. cotton, wool, rayon, silk, or blends of these materials) may be used as underlayers beneath FR apparel Meltable fibers such as acetate, nylon, polyester, polypropylene, and spandex shall not be permitted in fabric underlayers next to the skin. (An incidental amount of elastic used on non-melting fabric underwear or socks shall be permitted) When FR apparel is required, garments worn as outer layers over FR apparel (i.e. jackets or rainwear) must also be made from FR material Flash suits must permit easy and rapid removal by the user. 6.4 Rubber Insulating Equipment Rubber insulating equipment includes protective devices such as gloves, sleeves, blankets, and matting Insulating equipment must be inspected for damage before each day s use and immediately following any incident that could have caused damage An air test must be performed on rubber insulating gloves before each use. To complete an air test, manually fill the glove with air. Fold over the cuff to seal the air inside the glove. Detect any leaking air by either listening for escaping air or feeling the escaping air by holding the glove near the face. Page 12 of 30

13 6.4.4 Insulating equipment found to have defects that might affect its insulating properties must be removed from service until testing indicates that it is acceptable for continued use Where the insulating capability of protective equipment is subject to damage during use, the insulating material shall be protected by an outer covering of leather or other appropriate material Rubber insulating equipment must be tested according to the schedule in Appendix G Rubber insulating equipment must be stored in an area protected from light, temperature extremes, excessive humidity, ozone, and other substances and conditions that may cause damage No repairs to rubber insulating equipment shall be attempted without the approval of the EHS Department. 7.0 Insulated Tools & Equipment: 7.1 Only insulated tools and equipment shall be used within the Limited Approach Boundary of exposed energized parts. 7.2 Insulated tools shall be rated for the voltages on which they are used. 7.3 Insulated tools shall be designed and constructed for the environment to which they are exposed and the manner in which they are used. 7.4 Fuse or fuse holder handling equipment, insulated for the circuit voltage, shall be used to remove or install a fuse if the fuse terminals are energized. 7.5 Ropes and handlines used near exposed energized parts shall be nonconductive. 7.6 Portable ladders used for electrical work shall have nonconductive side rails. 8.0 Labeling: 8.1 All switchboards, panel boards, industrial panels, motor control centers, and meter socket enclosures shall be labeled using a label similar to the one found in Appendix H. Page 13 of 30

14 9.0 Alerting Techniques: 9.1 Barricades shall be used in conjunction with safety signs to prevent or limit access to work areas containing live parts. Conductive barricades shall not be used where they might cause an electrical hazard. Barricades shall be placed no closer than the Limited Approach Boundary. 9.2 If signs and barricades do not provide sufficient protection, an attendant will be assigned to warn and protect pedestrians. The primary duty of the attendant shall be to keep unqualified persons out of the work area where an electrical hazard exists. The attendant shall remain in the area as long as there is a potential exposure to electrical hazards Contract Employees: 10.1 PSU shall inform contractors engaged in electrical work of any known hazards applicable to the work being performed. Contractors are required to follow all applicable OSHA regulations and NFPA 70E standards. Page 14 of 30

15 Appendix A: Energized Electrical Work Permit Part I: To be completed by the requester or supervisor of the job (1) Identify requester: Name: Work Unit: (2) Job location: (3) Description of work to be done: (4) Explain why the circuit cannot be deenergized or the work delayed until the next scheduled outage: (5) Signature of requester: Title: Part II: To be completed by the qualified person(s) completing the work (6) Description of circuit and equipment: (7) Detailed description of procedure to be used in performing the above work: (8) Safe work practices to be used: (Check all that apply) -conductive covers/blankets (Describe) (9) Maximum Voltage that will be exposed: (10) What rating is the upstream protective device? (Amperage): (11) Limited, Restricted and Prohibited Boundaries for shock hazard: Refer to the arc flash label (if present), if not see Appendix B of this program or Table 130.2(c) in the NFPA 70E 2009 standard) Limited boundary = Restricted boundary = Prohibited boundary = (12) Determination of flash protection boundaries:, based on the product of clearing time of 2 cycles (0.033 sec) and the available bolted fault current of 50 KA or any combination not exceeding 100 ka cycles (1667 ampere seconds). (13) Hazard/Risk Category (See Appendix D of this program): Page 15 of 30

16 (14) PPE required to safely perform the task: (Either see Appendix C and D of this program, Tables 130.7(c)(9) and 130.7(c)(10) in the NFPA 70E 2009 standard, or Appendix E) - Check all that apply. - Circle class of PPE and minimum calorie rating where applicable. class 00, 0, 1, 2, 3, 4 (non-melting) -melting) - Calorie rating 4, 8, 25, 40 - Calorie rating 4, 8, 25, 40 - (Class C up to 2,200 Volts / Class G up to - Calorie rating 4, 8, 25, 40 20,000 Volts) - (Class C up to 2,200 Volts / Class G up to 20,000 Volts) - Calorie rating 4, 8, 25, 40 Flash suit- Calorie rating 4, 8, 25, 40 - Calorie rating 4, 8, 25, 40 Dielectric over-boots/shoes Balaclava (sock hood) Hazard/Risk Category 2* only -shield - Calorie rating 4, 8, 25, 40 (15) Method used to restrict access to the work area: (tape, physical barrier) (16) Will a job briefing be completed that covers all of the following items? controls D (Forward to EHS) Return to requester) Note that additional information may be requested by the PSU Electrical Safety Committee. Qualified Person performing work: Date: Qualified Person performing work: Date: Attendant: Date: Qualified Person s Supervisor: Date: Part III: To be completed by members of PSU Electrical Safety Committee Approvals: Safety Officer (UP): Signature Job Title Date Commonwealth Services Representative (Campus): Signature Job Title Date Electrical Engineer (OPP): Signature Job Title Date EHS: Signature Job Title Date Permit Expiration Date: Page 16 of 30

17 Nominal System Voltage (phase to phase) PSU Energized Electrical Safety Program Appendix B: Approach Boundaries to Live Parts for Shock Protection (All dimensions are distance from live part to employee) Limited Approach Boundary (fixed circuit parts only) Restricted Approach Boundary (includes inadvertent movement adder) Prohibited Approach Boundary Less than 50 V Not Specified Not Specified Not Specified 50 V to 300 V 3 feet, 6 inches Avoid Contact Avoid Contact 301 V to 750 V 3 feet, 6 inches 1 foot 1 inch 751 V to 15 kv 5 feet 2 feet, 2 inches 7 inches Over 15 kv or movable conductor See NFPA 70 E Table (C) Limited Approach Boundary: Distance from an exposed live part within which a shock hazard exists. An unqualified person may not cross this boundary unless they are continuously escorted by a qualified person. Restricted Approach Boundary: Distance from an exposed live part within which there is an increased risk of shock (due to electrical arc-over combined with inadvertent movement) for personnel working in close proximity to the live part. This boundary may only be crossed by a qualified person who is safely insulated or guarded from the live parts. Prohibited Approach Boundary: Distance from an exposed live part within which work is considered the same as making contact with the live part. This boundary may only be crossed by a qualified person who has specific training to work on energized parts; has obtained an approved Energized Electrical Work Permit; and uses PPE appropriate for working on energized parts which are rated for the voltage and energy level involved. (Note: A permit is not required for work related to testing, troubleshooting, and voltage measuring). Flash Protection Boundary (not listed in table): Distance from exposed live parts within which a person could receive a second degree burn if an electrical arc flash were to occur. This boundary may only be crossed by a qualified person wearing the appropriate PPE. For systems that are 600 volts or less, the Flash Protection Boundary shall be a minimum of four feet, based on the product of clearing time of 2 cycles (0.033 sec) and the available bolted fault current of 50 KA or any combination not exceeding 100 ka cycles (1667 ampere seconds). (The Flash Protection Boundary for systems under 600 volts that do not meet the above criteria or are above 600 Volts will be determined by an Electrical Engineer). An engineering analysis must be performed to determine the Flash Protection Boundary for systems that are above 600 volts. Page 17 of 30

18 Appendix C: Hazard/Risk Category Classifications Tasks Performed on Energized Equipment Panelboards Rated 240 V and Below (See Note 1) Perform infrared thermography and other non-contact Hazard/Risk Category Rubber Insulating Gloves Insulated and Insulating Hand Tools 0 N N inspections outside the restricted approach boundary Circuit breaker (CB) or fused switch operation with 0 N N covers on CB or fused switch operation with covers off 0 N N Work on energized parts, including voltage testing 1 Y Y Remove/install CBs or fused switches 1 Y Y Removal of bolted covers (to expose bare, energized electrical conductors and circuit parts) 1 N N Opening hinged covers (to expose bare, energized electrical conductors and circuit parts) 0 N N Work on energized electrical conductors and circuit parts fed directly by a branch circuit of the panelboard 1 Y Y Panelboards or Switchboards Rated > 240 V and up to 600 V (with molded case or insulated case circuit breakers) (See Note 1) Perform infrared thermography and other non-contact 1 N N inspections outside the restricted approach boundary CB or fused switch operation with covers on 0 N N CB or fused switch operation with covers off 1 Y N Work on energized electrical conductors and circuit parts, including voltage testing 2 * Y Y Work on energized electrical conductors and circuit parts of utilization equipment fed directly by a branch circuit of the panelboard or switchboard 2* Y Y Other 600 V Class (277 V through 600 V, nominal) Equipment - Note 2 (except as indicated) Removal of bolted covers (to expose bare, energized electrical conductors and circuit parts) Opening hinged covers (to expose bare, energized electrical conductors and circuit parts) Work on energized electrical conductors and circuit parts, including voltage testing. 2* N N 1 N N 2* Y Y Application of safety grounds, after voltage testing 2* Y N Additional Information: See NFPA 70E Table 130.7(C)(9) for more tasks and voltages Rubber insulating gloves are gloves rated for the maximum line-to-line voltage upon which work will be done. Insulated and insulating hand tools are tools rated and tested for the maximum line-to-line voltage upon which work will be done, and are manufactured and tested in accordance with ASTM F 1505, Standard Specification for Insulated and Insulating Hand Tools. Y = Yes (required) N = No (not required) Notes: (1) Maximum of 25 ka short circuit current available; maximum of 0.03 second (2 cycle) fault clearing time. (2) Maximum of 65 ka short circuit current available; maximum of 0.03 second (2 cycle) fault clearing time. Page 18 of 30

19 Appendix D: Protective Clothing and Personal Protective Equipment (PPE) Matrix Hazard/Risk Category Protective Clothing and PPE Hazard/Risk Category 0 Protective Clothing, Nonmelting (according to ASTM F ) or Untreated Natural Fiber (i.e., untreated cotton, wool, rayon, or silk, or blends of these materials with a fabric weight of at least 4.5 oz/yd 2 ) FR Protective Equipment Hazard/Risk Category 1 FR Clothing, Minimum Arc Rating of 4 cal/cm 2 (Note 1) FR Protective Equipment Hazard/Risk Category 2 FR Clothing, Minimum Arc Rating of 8 cal/cm 2 (Note 1) FR Protective Equipment Hazard/Risk Category 2* FR Clothing, Minimum Arc Rating of 8 cal/cm 2 (Note 1) FR Protective Equipment Shirt (long sleeve) and Pants (long) Safety glasses or safety goggles (ear canal inserts) Leather gloves (As needed) (Note 2) Arc-rated long-sleeve shirt and pants (Note 3) or Arc- rated coveralls (Note 4) Arc-rated face shield or arc flash suit hood (Note 7) Arc-rated jacket, parka, or rainwear (As needed) Hard hat Safety glasses or safety goggles (ear canal inserts) Leather gloves (Note 2) Leather work shoes (As needed) Arc-rated long-sleeve shirt and pants (Note 5) or Arc-rated coveralls (Note 6) Arc-rated face shield or arc flash suit hood (Note 7) Arc-rated jacket, parka, or rainwear (As needed) Hard hat Safety glasses or safety goggles (ear canal inserts) Leather gloves (Note 2) Leather work shoes Arc-rated long-sleeve shirt and pants (Note 5) or Arc-rated coverall (Note 6) Arc-rated arc flash suit hood (Note 10) Arc-rated jacket, parka, or rainwear (As needed) Hard hat Safety glasses or safety goggles (ear canal inserts) Leather gloves (Note 2) Leather work shoes Page 19 of 30

20 Hazard/Risk Category 3 FR Clothing, Minimum Arc Rating of 25 cal/cm 2 (Note 1) FR Protective Equipment Hazard/Risk Category 4 FR Clothing, Minimum Arc Rating of 40 cal/cm 2 (Note 1) FR Protective Equipment Arc-rated long-sleeve shirt and pants (Note 8) or Arc-rated coverall (Note 8) Arc-rated flash suit jacket (Note 8) Arc-rated flash suit pants (Note 8) Arc-rated flash suit hood (Note 8) Arc-rated jacket, parka, or rainwear (As needed) Hard hat with FR hard hat liner Safety glasses or safety goggles (ear canal inserts) Arc-rated gloves (Note 2) Leather work shoes Arc-rated long-sleeve shirt and pants (Note 9) or Arc-rated coverall (Note 9) Arc-rated flash suit jacket (Note 9) Arc-rated flash suit pants (Note 9) Arc-rated flash suit hood (Note 9) Arc-rated jacket, parka, or rainwear (As needed) Hard hat with FR hard hat liner Safety glasses or safety goggles (ear canal inserts) Leather gloves (Note 2) Leather work shoes Notes: 1. See Table (C) (11). Arc rating for a garment or system of garments is expressed in cal/cm If rubber insulating gloves with leather protectors are required, additional leather or arc-rated gloves are not required. The combination of rubber insulating gloves with leather protectors satisfies the arc flash protection requirement. 3. The FR shirt and pants used for Hazard/Risk Category 1 shall have a minimum arc rating of 4 cal/cm 2 4. Alternate is to use FR coveralls (minimum arc rating of 4 cal/cm 2 ) instead of FR shirt and FR pants 5. FR shirt and FR pants used for Hazard/Risk Category 2 shall have a minimum arc rating of 8 cal/cm 2 6. Alternate is to use FR coveralls (minimum arc rating of 8 cal/cm 2 ) instead of FR shirt and FR pants. 7. A face shield with a minimum arc rating of 4 cal/cm 2 for Hazard Risk Category 1 or a minimum arc rating of 8 cal/cm 2 for Hazard/Risk Category 2, with wrap-around guarding to protect not only the face, but also the forehead, ears, and neck (or alternatively, a flash suit hood), is required. 8. An alternate is to use a total FR clothing system and hood, which shall have a minimum arc rating of 25 cal/cm 2 for Hazard/Risk Category The total clothing system consisting of FR shirt and pants and/or FR coveralls and/or arc flash coat and pants and hood shall have a minimum arc rating of 40 for Hazard/Risk Category Alternate is to use face shield with a minimum arc rating of 8 cal/cm 2 and a balaclava (sock hood) with a minimum arc rating of 8 cal/cm 2 and which covers the face, head and neck except for the eye and nose areas. Page 20 of 30

21 Appendix E PPE for Common Electrical Work Tasks at PSU (Not an all inclusive listing of work tasks) (PPE contingent on criteria found in the Notes section of Appendix C) Panelboards or other equipment rated 240 V and below Job Tasks performed on energized equipment Perform infrared thermography and other noncontact inspections outside the restricted approach boundary. (hazard/risk category 0) Circuit breaker or fused switch operation with covers on. (hazard/risk category 0) Circuit breaker or fused switch operation with covers off. (hazard/risk category 0) Protective Requirements Non-melting or untreated natural fiber: Long sleeve shirt Long pants Safety glasses or safety goggles Leather gloves (as needed) Non-melting or untreated natural fiber: Long sleeve shirt Long pants Safety glasses or safety goggles Leather gloves (as needed) Non-melting or untreated natural fiber: Long sleeve shirt Long pants Safety glasses or safety goggles Leather gloves (as needed) Page 21 of 30

22 Panelboards or other equipment rated 240 V and below Job Tasks performed on energized equipment Work on energized electrical conductors and circuit parts, including voltage testing and troubleshooting. (hazard/risk category 1) Remove or install circuit breakers or fused switches. (hazard/risk category 1) Protective Requirements FR Clothing, minimum arc rating of 4: Long sleeve shirt and long pants (Cal rating of 4) OR Coveralls (Cal rating of 4) Face-shield or flash suit hood (Cal rating of 4) Jacket, parka, or rainwear (as needed based on conditions) Hardhat Safety glasses or goggles Rubber insulating gloves Leather gloves Leather work shoes (as needed) FR Clothing, minimum arc rating of 4: Long sleeve shirt and long pants (Cal rating of 4) OR Coveralls (Cal rating of 4) Face-shield or flash suit hood (Cal rating of 4) Jacket, parka, or rainwear (as needed based on conditions) Hardhat Safety glasses or goggles Rubber insulating gloves Leather gloves Leather work shoes (as needed) Page 22 of 30

23 Panelboards or other equipment rated 240 V and below Job Tasks performed on energized equipment Removal of bolted covers (to expose bare, energized electrical conductors and circuit parts). (hazard/risk category 1) Opening hinged covers (to expose bare, energized electrical conductors and circuit parts). (hazard/risk category 0) Work on energized electrical conductors and circuit parts of utilization equipment fed directly by branch circuit of the panelboard. (hazard/risk category 1) Protective Requirements FR Clothing, minimum arc rating of 4: Long sleeve shirt and long pants (Cal rating of 4) OR Coveralls (Cal rating of 4) Face-shield or flash suit hood (Cal rating of 4) Jacket, parka, or rainwear (as needed based on conditions) Hardhat Safety glasses or goggles Leather gloves Leather work shoes (as needed) Non-melting or untreated natural fiber: Shirt (long sleeve) Pants (long) Safety glasses or safety goggles Leather gloves (as needed) FR Clothing, minimum arc rating of 4: Long sleeve shirt and long pants (Cal rating of 4) OR Coveralls (Cal rating of 4) Face-shield or flash suit hood (Cal rating of 4) Jacket, parka, or rainwear (as needed based on conditions) Hardhat Safety glasses or goggles Rubber insulating gloves Leather gloves Leather work shoes (as needed) Page 23 of 30

24 Panelboards or Switchboards Rated greater than 240 V and up to 600 Volts (with molded case or insulated case circuit breakers) Job Tasks performed on energized equipment Perform infrared thermography and other noncontact inspections outside the restricted approach boundary. (hazard/risk category 1) Circuit or fused switch operation with covers on. (hazard/risk category 0) Circuit breaker or fused switch operation with covers off. (hazard/risk category 1) Protective Requirements FR Clothing, minimum arc rating of 4: Long sleeve shirt and long pants (Cal rating of 4) OR Coveralls (Cal rating of 4) Face-shield or flash suit hood (Cal rating of 4) Jacket, parka, or rainwear (as needed based on conditions) Hardhat Safety glasses or goggles Leather gloves Leather work shoes (as needed) Non-melting or untreated natural fiber: Shirt (long sleeve) Pants (long) Safety glasses or safety goggles Leather gloves (as needed) FR Clothing, minimum arc rating of 4: Long sleeve shirt and long pants (Cal rating of 4) OR Coveralls (Cal rating of 4) Face-shield or flash suit hood (Cal rating of 4) Jacket, parka, or rainwear (as needed based on conditions) Hardhat Safety glasses or goggles Rubber insulating gloves Leather gloves Leather work shoes (as needed) Page 24 of 30

25 Panelboards or Switchboards Rated greater than 240 V and up to 600 Volts (with molded case or insulated case circuit breakers) Job Tasks performed on energized equipment Work on energized electrical conductors and circuit parts, including voltage testing and troubleshooting. (hazard/risk category 2*) Protective Requirements FR Clothing, minimum arc rating of 8: Long sleeve shirt AND long pants (Cal rating of 8) OR Coveralls (Cal rating of 8) Arc flash suit hood OR Face shield (Cal rating of 8) AND Balaclava (Cal rating of 8) Jacket, parka, or rainwear (as needed based on conditions) Work on energized electrical conductors and circuit parts of utilization equipment fed directly by a branch circuit of the panelboard or switch. (hazard/risk category 2*) Hardhat Safety glasses or goggles Rubber insulating gloves Leather gloves Leather work shoes FR Clothing, minimum arc rating of 8: Long sleeve shirt AND long pants (Cal rating of 8) OR Coveralls (Cal rating of 8) Arc flash suit hood OR Face shield (Cal rating of 8) AND Balaclava (Cal rating of 8) Jacket, parka, or rainwear (as needed based on conditions) Hardhat Safety glasses or goggles Rubber insulating gloves Leather gloves Leather work shoes Page 25 of 30

26 Other 600 V Class (277 V through 600 V, nominal) Equipment Job Tasks performed on energized equipment Protective Requirements Lighting or small power transformers (600 V, maximum) Removal of bolted covers (to expose bare, energized electrical conductors and circuit parts) (hazard/risk category 2*) FR Clothing, minimum arc rating of 8: Long sleeve shirt AND long pants (Cal rating of 8) OR Coveralls (Cal rating of 8) Arc flash suit hood OR Face shield (Cal rating of 8) AND Balaclava (Cal rating of 8) Jacket, parka, or rainwear (as needed based on conditions) Opening hinged covers (to expose bare, energized electrical conductors and circuit parts) (hazard/risk category 1) Hardhat Safety glasses or goggles Leather gloves Leather work shoes FR Clothing, minimum arc rating of 4: Long sleeve shirt and long pants (Cal rating of 4) OR Coveralls (Cal rating of 4) Face-shield or flash suit hood (Cal rating of 4) Jacket, parka, or rainwear (as needed based on conditions) Hardhat Safety glasses or goggles Leather gloves Leather work shoes (as needed) Page 26 of 30

27 Other 600 V Class (277 V through 600 V, nominal) Equipment Job Tasks performed on energized equipment Work on energized electrical conductors and circuit parts, including voltage testing. (hazard/risk category 2*) Protective Requirements FR Clothing, minimum arc rating of 8: Long sleeve shirt AND long pants (Cal rating of 8) OR Coveralls (Cal rating of 8) Arc flash suit hood OR Face shield (Cal rating of 8) AND Balaclava (Cal rating of 8) Jacket, parka, or rainwear (as needed based on conditions) Application of safety grounds, after voltage testing (hazard/risk category 2*) Hardhat Safety glasses or goggles Rubber Insulating gloves Leather gloves Leather work shoes FR Clothing, minimum arc rating of 8: Long sleeve shirt AND long pants (Cal rating of 8) OR Coveralls (Cal rating of 8) Arc flash suit hood OR Face shield (Cal rating of 8) AND Balaclava (Cal rating of 8) Jacket, parka, or rainwear (as needed based on conditions) Hardhat Safety glasses or goggles Rubber Insulating gloves Leather gloves Leather work shoes Page 27 of 30

28 Appendix F: Work Unit PPE Requirements for Energized Tasks Description of Task Equipment Voltage Hazard/Risk Category Specific PPE To Be Worn Page 28 of 30

29 Appendix G: Inspection Schedule for Rubber Insulating Equipment Type of Equipment Rubber insulating line hose Rubber insulating covers Rubber insulating blankets Rubber insulating gloves Rubber insulating sleeves When to Test Upon indication that insulating value is suspect Upon indication that insulating value is suspect Before first issue and every 12 months thereafter (*) Before first issue and every 6 months thereafter (*) Before first issue and every 12 months thereafter (*) (*) If the insulating equipment has been electrically tested but not issued for service, it may not be placed into service unless is has been electrically tested within the previous 12 months. Page 29 of 30

30 Appendix H: Arc Flash Warning Label (Example) Page 30 of 30

Electrical Safety Program

Electrical Safety Program Facilities Operations and Development Environmental Health and Safety 1314 Kinnear Road #106 Columbus, OH 43212-1168 614-292-1284 Phone 614-292-6404 Fax www.ehs.osu.edu Electrical Safety Program Prepared

More information

Electrical & Arc Flash Safety Program 2007

Electrical & Arc Flash Safety Program 2007 University of Louisville Physical Plant Department Electrical & Arc Flash Safety Program 2007 Introduction Electricity is a serious workplace hazard, capable of causing both employee injury and property

More information

Appendix A: Energized Work Permit

Appendix A: Energized Work Permit Appendix A: Energized Work Permit Part I: To be completed by the Supervisor Description of Circuit & Equipment: Job Location: Description of Work to Be Done: Justification of why the circuit cannot be

More information

IWU PHYSICAL PLANT SAFETY PROGRAM. Revision: 1 ELECTRICAL SAFETY Section: 4

IWU PHYSICAL PLANT SAFETY PROGRAM. Revision: 1 ELECTRICAL SAFETY Section: 4 STANDARDS Title 29 Code of Federal Regulations (CFR) Part 1910 Subpart S 301-399; NFPA 70E 2012 1.0 INTRODUCTION Electricity is a serious workplace hazard, capable of causing both employee injury and property

More information

This is (Enter Company Name Here) Arc Flash Prevention policy. (Enter Name Here) will be responsible for overall direction of the Safety Program.

This is (Enter Company Name Here) Arc Flash Prevention policy. (Enter Name Here) will be responsible for overall direction of the Safety Program. Company Name: Policy/Procedure ID Number: 222 Date: Grainger Safety Services Inc. 2012 Arc Flash Prevention Policy This is (Enter Company Name Here) Arc Flash Prevention policy. (Enter Name Here) will

More information

Electrical Safety Program

Electrical Safety Program Electrical Safety Program The University Of Iowa Environmental Health & Safety 122 Grand Avenue Court Iowa City, IA 52242-1000 Phone: 319-335-8501 Date Revised/Reviewed: 6/8/2018 Table of Contents 1. Summary...

More information

Selection of Electrical PPE Tables

Selection of Electrical PPE Tables Selection of Electrical PPE Tables Instructions Table 1 - Starting with Table 1, select the task you plan to do (right-hand column) and the condition of the equipment you will be working on, (center column).

More information

MISSOURI UNIVERSITY OF SCIENCE & TECHNOLOGY Procedure: 3.6

MISSOURI UNIVERSITY OF SCIENCE & TECHNOLOGY Procedure: 3.6 Procedure This electrical safety procedure structures safety procedures to meet the requirements of the NFPA-70E Standard. The program is designed for qualified employees who occasionally must perform

More information

Electrical Safety Program

Electrical Safety Program Electrical Safety Program For Adopted LC-1005 Rev. 06/16 Page 1 I. Introduction As part of Organization s overall safety and health program, an

More information

2012 NFPA 70E: Electrical Safety In The Workplace

2012 NFPA 70E: Electrical Safety In The Workplace ERI Safety Videos Preventing Injuries Through Employee Training 2984 2012 NFPA 70E: Electrical Safety In The Workplace Leader s Guide ERI Safety Videos 2012 NFPA 70E: Electrical Safety In The Workplace

More information

ARC FLASH INTRODUCTION. Injuries

ARC FLASH INTRODUCTION. Injuries Arc flash occurs when electricity arcs and results in radiation and shrapnel being created. It occurs when electrical insulation or isolation between conductors is broken or can no longer withstand the

More information

Leader s Guide ERI Safety Videos

Leader s Guide ERI Safety Videos 1717 SAFE ELECTRICAL WORK PRACTICES & THE 2018 NFPA 70E Leader s Guide ERI Safety Videos SAFE ELECTRICAL WORK PRACTICES & THE 2018 NFPA 70E This easy-to-use Leader s Guide is provided to assist in conducting

More information

Electrical Safety Program

Electrical Safety Program 1.0 POLICY It is the policy of the California State University, Sacramento (Sac State) to provide its employees with a safe and healthful workplace. To reduce or eliminate the dangers associated with the

More information

Electrical Safety Work Practices

Electrical Safety Work Practices Work Practices I. SCOPE This program covers any SOUTHWESTERN COMMUNITY COLLEGE employee that may work or be exposed to exposed electrical systems: To assure that employees are not exposed to potentially

More information

Original Date of Issue: 04/09

Original Date of Issue: 04/09 POLICIES AND PROCEDURES DEPARTMENT: Environmental Health and Safety SUBJECT: Electrical Safety Program Original Date of Issue: 04/09 Reviewed 12/2011 Revised 12/2011 BACKGROUND ELECTRIC SHOCK It is well

More information

Leader s Guide ERI Safety Videos

Leader s Guide ERI Safety Videos 1419 SAFE ELECTRICAL WORK PRACTICES & 2015 NFPA 70E Leader s Guide ERI Safety Videos SAFE ELECTRICAL WORK PRACTICES & 2015 NFPA 70E This easy-to-use Leader s Guide is provided to assist in conducting a

More information

D Square Construction LLC

D Square Construction LLC D Square Construction LLC Lock Out-Tag Out (LOTO) and Zero Voltage Verification (ZVV) Process and Plan Energized Work Process and Permit - 1 - Table of Contents 1) Instruction for using Decision Tree Analysis

More information

Campus Safety Procedure Electrical Safety

Campus Safety Procedure Electrical Safety ELECTRICAL SAFETY PROCEDURE CSU DOMINGUEZ HILLS RM / EHOS MAY 2010 Campus Safety Procedure Electrical Safety Electrical Safety Procedures 1.0 Purpose The purpose of this procedure is to provide guidance

More information

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , , ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR 1910.331 335-29 CFR 1926.302, 1926.416, 1926.417 BASIS: The National Safety Council estimates that there are at least 300 deaths

More information

The following general approach will be used when conducting energized electrical work.

The following general approach will be used when conducting energized electrical work. BEI Energized Electrical Work Safety Procedures 1.0 Purpose The safest way to conduct electrical work is to shut off electric power and work on de-energized equipment. At BEI our intent and standard practice

More information

SECTION 51 NFPA 70E POLICY. Health & Safety Policy and Procedures Manual

SECTION 51 NFPA 70E POLICY. Health & Safety Policy and Procedures Manual SECTION 51 NFPA 70E POLICY Health & Safety Policy and 1. Protection Against Arc Flash A. Policy: An arc flash is a dangerous condition associated with the release of energy caused by an electric arc. An

More information

Portland Community College Facilities Management Services ENERGIZED ELECTRICAL WORK PERMIT AND WORK PLAN

Portland Community College Facilities Management Services ENERGIZED ELECTRICAL WORK PERMIT AND WORK PLAN Portland Community College Facilities Management Services ENERGIZED ELECTRICAL WORK PERMIT AND WORK PLAN Section 1 - PROJECT INFORMATION Project Work Request No. Building Room/Location Equip. Serial No.

More information

ELECTRICAL SAFETY PROCEDURE

ELECTRICAL SAFETY PROCEDURE ELECTRICAL SAFETY PROCEDURE 1 Table of Contents 1 PURPOSE... 3 2 PROGRAM COMPLIANCE... 3 3 SCOPE... 3 4 DEFINITIONS... 3 5 RESPONSIBILITES... 3 6 ELECTRICA HAZARDS... 4 7 TRAINING... 4 8 PORTABLE ELECTRICAL

More information

Electrical Hazards: Overhead and underground power lines. tools. Ungrounded electrical systems and tools. in wet/damp environments

Electrical Hazards: Overhead and underground power lines. tools. Ungrounded electrical systems and tools. in wet/damp environments ELECTRICAL SAFETY Electrical hazards pose a serious threat to worker safety. Many workers are unaware of the potential electrical hazards present in their work environment which makes them more vulnerable

More information

ARC FLASH HAZARD ANALYSIS

ARC FLASH HAZARD ANALYSIS I. ARC FLASH HAZARD ANALYSIS IS REQUIRED ARC FLASH HAZARD ANALYSIS By Mike Lang Principal Field Engineer OSHA s 29 CFR Part 1910.132(d) states: The employer shall assess the workplace to determine if hazards

More information

Preparer: Owner: Approver: EHS Team Member TES Manager Site Manager

Preparer: Owner: Approver: EHS Team Member TES Manager Site Manager Procedure No.: BMEHS-002.033 Page: 1 of 10 Preparer: Owner: Approver: EHS Team Member TES Manager Site Manager Document Revision Change Table Revision Revision Description Revised Revision Number New By

More information

2. The purpose of this program is to achieve the following objectives:

2. The purpose of this program is to achieve the following objectives: Section 16A. Lockout and Tagout Program 1. In the course of their duties, personnel at the TFREC may need to secure controls, switches, and equipment in order to prevent injury caused by the sudden, unexpected

More information

Management Plan for Electrical Safety ISD #535

Management Plan for Electrical Safety ISD #535 Management Plan for Electrical Safety ISD #535 Health & Safety Office Maintenance Service Building 10 SE 9 ½ Street Rochester, MN 55904 507-328-4507 MANAGEMENT PLAN FOR ELECTRICAL SAFETY Table of Contents

More information

Why do I need to do an Arc-Flash Analysis?

Why do I need to do an Arc-Flash Analysis? Why do I need to do an Arc-Flash Analysis? Presented By Tom Norwood for Alexander Nizov, P.E. Principal/Manager Electrical Engineering Division TRAINING INSTITUTE, INC. A SUBSIDIARY OF MEGGER Hazards Analysis

More information

arc flash hazard analysis

arc flash hazard analysis arc flash hazard analysis arc flash note 3 By mike lang, principal field engineer Arc Flash Hazard Analysis is Required OSHA s 29 CFR Part 1910.132(d) states: The employer shall assess the workplace to

More information

Electrical Safety Program February 2, 2016

Electrical Safety Program February 2, 2016 Electrical Safety Program February 2, 2016 1. INTRODUCTION 1.1. Purpose Indiana University Environmental Health and Safety (IUEHS) has developed the Electrical Safety Program to protect employees from

More information

Welcome to this training session about arc flash. In this session, we ll talk about the hazards and risks of working around exposed, energized

Welcome to this training session about arc flash. In this session, we ll talk about the hazards and risks of working around exposed, energized Welcome to this training session about arc flash. In this session, we ll talk about the hazards and risks of working around exposed, energized electrical equipment. We ll also discuss common arc flash

More information

USA Mobile, AL Electrical Safe Working Practices

USA Mobile, AL Electrical Safe Working Practices Compliance Compliance with these safe work practices is mandatory. Failure to comply may result in disciplinary action. These Safe Working Practices apply to any person performing electrical work at the

More information

ELECTRICAL SAFE WORK PRACTICES

ELECTRICAL SAFE WORK PRACTICES STAFF ELECTRIC ELECTRICAL SAFE WORK PRACTICES PURPOSE The purpose of this procedure is to protect all workers from injuries resulting from exposure to arc flash, arc blast and electrical shock and to comply

More information

Electrical Safety Program

Electrical Safety Program Electrical Safety Program Date of last revision: October, 2011-485 - Electrical Safety Program Update No updates. - 486 - Electrical Safety Program Update...486 (I) Purpose...488 (II) Policy...488 (III)

More information

Progressive Safety Services LLC - All Rights Reserved

Progressive Safety Services LLC - All Rights Reserved Estimated that 2,000 workers are treated in specialized burn centers each year as a result of arc flash (Electrical Safety Foundation International). According to the National Safety Council, medical costs

More information

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Electrical Safety Standard

CITY AND COUNTY OF DENVER CR&CF RISK UNIT Electrical Safety Standard CITY AND COUNTY OF DENVER CR&CF RISK UNIT 65.5.3 Electrical Safety Standard 1.0 Introduction 2.0 Scope The purpose of this standard is to establish safe work practices that are intended to prevent electric

More information

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY Revision No.: 3 Page 1 of 30 I. PURPOSE Electricity is a serious workplace hazard, capable of causing both employee injury and property damage. It is the policy of the University of Rochester (U of R),

More information

EVEREADY BATTERY BENNINGTON, VERMONT FACILITY SPECIFIC HOUSE RULES FOR OUTSIDE CONTRACTORS

EVEREADY BATTERY BENNINGTON, VERMONT FACILITY SPECIFIC HOUSE RULES FOR OUTSIDE CONTRACTORS EVEREADY BATTERY BENNINGTON, VERMONT FACILITY SPECIFIC HOUSE RULES FOR OUTSIDE CONTRACTORS C:\_Data\_MOC_Program\_2010_updates\_Benn\Bennington_House Rules rel 12-2010.doc Page 1 of 12 TABLE OF CONTENTS

More information

KMU SUBSTATION WORKSHOP

KMU SUBSTATION WORKSHOP Rick Aguilar, Director of Job Training & Safety KMU SUBSTATION WORKSHOP JUNE 29-30, 2016 OTTAWA, KS Hazards & Safety Rules Qualified Personnel & Task-Based Hazard Mitigation Worksite Applications & Considerations

More information

Definitions found in several locations:

Definitions found in several locations: Definitions found in several locations: NFPA 70 - National Electric Code NFPA 70B Recommended Practice for Electrical Equipment Maintenance. NFPA 70E Electrical Safety in the Workplace OSHA 1910 Subpart

More information

Duke University - Facilities Management Department Environmental Safety and Health Program ELECTRICAL SAFETY PROGRAM

Duke University - Facilities Management Department Environmental Safety and Health Program ELECTRICAL SAFETY PROGRAM ELECTRICAL SAFETY PROGRAM Applicable to: All FMD Organizations Date Effective: 7/1/2014 Issue No.: 1 Revision: 0 Page 1 of 9 A. Purpose 1. To establish a written electrical safety program that promotes

More information

POWER DELIVERY. Contractor Health & Safety General Terms and Conditions. Appendix B Personal Protective Equipment

POWER DELIVERY. Contractor Health & Safety General Terms and Conditions. Appendix B Personal Protective Equipment Personal Protective Equipment ( PPE ): All PPE worn on IPL job sites must have ANSI and/or approval ratings. Hard hats and safety glasses with side shields (including prescription eyewear) shall be worn

More information

Electrical Safety Program

Electrical Safety Program Environmental Safety Electrical Safety Program 50V-1000V The purpose of Clemson University s (CU) Electrical Safety Program is to protect all staff, students, and faculty from electrical hazards. Clemson

More information

2017 NWHA TECHNICAL SEMINAR. Arc Flash Hazard Awareness MIKE BRENDLE LLC

2017 NWHA TECHNICAL SEMINAR. Arc Flash Hazard Awareness MIKE BRENDLE LLC 2017 NWHA TECHNICAL SEMINAR Arc Flash Hazard Awareness WHAT IS ARC FLASH Arc Flash is a short circuit that flashes from one exposed live part to another, or to ground The result is ionized air that creates

More information

CALIFORNIA STATE UNIVERSITY, LOS ANGELES ELECTRICAL SAFETY PROGRAM

CALIFORNIA STATE UNIVERSITY, LOS ANGELES ELECTRICAL SAFETY PROGRAM CALIFORNIA STATE UNIVERSITY, LOS ANGELES ELECTRICAL SAFETY PROGRAM January 2017 PROGRAM APPROVAL AND AUTHORIZATION William A. Covino, President Date TABLE OF CONTENTS TITLE SECTION PURPOSE 1.0 ORGANIZATIONS

More information

Responsibilities / Accountability

Responsibilities / Accountability Responsibilities / Accountability What we will cover Brief history of OPP safety program OPP s commitment to safety Safety responsibilities Accountability for safety Employee expectations History of Safety

More information

WHAT IS THE N.F.P.A. 70E

WHAT IS THE N.F.P.A. 70E WHAT IS THE N.F.P.A. 70E N.F.P.A. 70E Standard for Electrical Safety in the Workplaces HAZARDS of ELECTRICITY FIRE-Faulty wiring-building fires. Clothing fires(arc flash). SHOCK-When electrical current

More information

to the 2009 Edition Standards & Codes Introduction Background Byron Jordan Sr. Field Engineer

to the 2009 Edition Standards & Codes Introduction Background Byron Jordan Sr. Field Engineer Critical Changes to the NFPA 70E Standard Standards & Codes Note 2 Byron Jordan Sr. Field Engineer Introduction Since its inception in 1979, NFPA 70E: Standards for Electrical Safety in the Workplace has

More information

Arc Flash. Safety 21

Arc Flash. Safety 21 Arc Flash Safety 21 Arc Flash Introduction Electrical Hazards Safety Planning De-Energizing Equipment Working Hot Summary Introduction Most people don t think about electricity very much, which is surprising

More information

Arc Flash 101. presented by Arc Flash Blaster LLC

Arc Flash 101. presented by Arc Flash Blaster LLC Arc Flash 101 presented by Arc Flash Blaster LLC ARC FLASH? ARC FLASH INCIDENT STANDARDS AND REGULATIONS Arc flash accidents... 35,000 F Molten Metal Pressure Waves Sound Waves Copper Vapour: (Solid to

More information

Removing Yourself from Hazards During Equipment Operation

Removing Yourself from Hazards During Equipment Operation Removing Yourself from Hazards During Equipment Operation The safest way to work around electrical equipment is to turn it off. This is usually required by OSHA and NFPA 70E, but with some exceptions.

More information

UNIVERSITY OF TOLEDO

UNIVERSITY OF TOLEDO UNIVERSITY OF TOLEDO SUBJECT: CONTROL OF HAZARDOUS ENERGY SOURCES Procedure No: S-08-014 (LOCK-OUT / TAGOUT) AND ELECTRICAL SAFE WORK PRACTICES PROCEDURE STATEMENT This program applies to all employees

More information

HIGH-IMPACT SAFETY TRAINING FOR QUALIFIED ELECTRICAL WORKERS

HIGH-IMPACT SAFETY TRAINING FOR QUALIFIED ELECTRICAL WORKERS HIGH-IMPACT SAFETY TRAINING FOR QUALIFIED ELECTRICAL WORKERS This easy-to-use Leaders Guide is provided to assist in conducting a successful presentation. Featured are: INTRODUCTION: A brief description

More information

11/2/2017. Course Objectives. Overview

11/2/2017. Course Objectives. Overview Course Objectives The objective of this CBT module is to insure that personnel receive basic training in electrical safety. Every employee's work involves electricity. This may vary from typical electrical

More information

Electrical Safety For Managers Updated For E. ElectricalTrainingPro.com

Electrical Safety For Managers Updated For E. ElectricalTrainingPro.com Electrical Safety For Managers Updated For 2018 70E Daryn Lewellyn daryn@electricaltrainingpro.com ElectricalTrainingPro.com 877.393.9901 1 Fatalities From Exposure To Electricity 1992-334 Bureau of Labor

More information

Health & Safety Policy and Procedures Manual SECTION 6 ELECTRICAL SAFETY / CONTROL OF HAZARDOUS ENERGY

Health & Safety Policy and Procedures Manual SECTION 6 ELECTRICAL SAFETY / CONTROL OF HAZARDOUS ENERGY SECTION 6 ELECTRICAL SAFETY / CONTROL OF HAZARDOUS ENERGY 1. CONTROL OF HAZARDOUS ENERGY POLICY AND PROCEDURES A. OSHA References: 29 CFR 1910.147, 29 CFR 1910.332, 29 CFR 1910.333, 29 CFR 1926.417 B.

More information

: Electric Power Generation, Transmission, and Distribution. Region IV - OSHA

: Electric Power Generation, Transmission, and Distribution. Region IV - OSHA 1910.269: Electric Power Generation, Transmission, and Distribution Region IV - OSHA Scope This standard covers the operation and maintenance of electric power generation, control, transformation transmission,

More information

Environmental, Health and Safety. Electrical Safety in the Workplace Program

Environmental, Health and Safety. Electrical Safety in the Workplace Program Environmental, Health and Safety Electrical Safety in the Workplace Program September 2016 Table of Contents 1.0 Purpose... 1 2.0 Scope... 1 3.0 Definitions... 2 4.0 Responsibilities... 7 5.0 Requirements...

More information

By: Bruce Bowman, P.E.

By: Bruce Bowman, P.E. Welcome to The NFPA 70E Electrical Safety Presentation Updated for 2012 www.nfpa.org By: Bruce Bowman, P.E. What is the best way to prevent the hazards of electricity? Stop Think Options Protection - Before

More information

Risk Assessment Procedure

Risk Assessment Procedure Voltage, current testing, troubleshooting Infrared inspection Visual inspection, data collecting Risk Register ES Acc 6 4 1 1 6 36 ES < Acc 6 4 3 3 10 60 AF/AB 40 Acc 8 3 2

More information

Health, Safety, Security and Environment

Health, Safety, Security and Environment Document owner and change code Document Owner Aaron Perronne Title HSSE Manager Mark X Change Code Description X N/A First Issue A Typographical/Grammatical correction; formatting change; text clarification-no

More information

Table of Contents. Note. Contents 1 through 13 are for non-authorized employees. Contents 14 through 16 are for authorized employees.

Table of Contents. Note. Contents 1 through 13 are for non-authorized employees. Contents 14 through 16 are for authorized employees. Table of Contents 1. Purpose... 3 2. Policy... 3 3. Responsibilities... 3 4. Definitions... 3 5. Electrical Safety Program Principles... 4 6. Safety Program Controls... 5 7. General Electrical Requirement

More information

100 Questions on Electrical Safety Study Guide

100 Questions on Electrical Safety Study Guide 100 Questions on Electrical Safety Study Guide Be advised that only 95 of 100 questions are presented here for the purpose of discouraging cheating on the final exam. 1. Why is electrical safety important?

More information

Electrical Safety & Arc Flash Awareness DYMAX ENGINEERING. Presented By Rick Edel

Electrical Safety & Arc Flash Awareness DYMAX ENGINEERING. Presented By Rick Edel Electrical Safety & Arc Flash Awareness DYMAX ENGINEERING Presented By Rick Edel Need for Electrical Safety PERSONAL SAFETY is of the utmost concern. Preventing personnel from being exposed to electricity

More information

ENVIRONMENTAL HEALTH AND SAFETY PERSONAL PROTECTIVE EQUIPMENT

ENVIRONMENTAL HEALTH AND SAFETY PERSONAL PROTECTIVE EQUIPMENT ENVIRONMENTAL HEALTH AND SAFETY PERSONAL PROTECTIVE EQUIPMENT PERSONAL PROTECTIVE EQUIPMENT Table of Contents A. Scope... 1 B. General Requirements... 1 C. Responsibility... 1 1. Supervisor... 1 2. Department

More information

Electrical Safety Program

Electrical Safety Program DEPAUL UNIVERSITY Electrical Safety Program Environmental Health & Safety November 2017 1 TABLE OF CONTENTS SECTION PAGE NO. 1.0 PURPOSE 2 2.0 SCOPE 2 3.0 RESPONSIBILITIES 2 4.0 TRAINING REQUIREMENTS 2

More information

HSE Procedure Energized and Potentially Energized Electrical Equipment Issuing Department: Corporate HSE

HSE Procedure Energized and Potentially Energized Electrical Equipment Issuing Department: Corporate HSE HSE Procedure Energized and Potentially Energized Electrical Equipment Issuing Department: Corporate HSE Previous Rev. & Issue Date: Rev. 2, 15 Aug 01 Effective Date: 3 Apr 06 Table of Contents 1.0 PURPOSE

More information

SAFE-WORK PRACTICES Working On Or Near Energized Electrical Equipment CAT A-1 SOP #4

SAFE-WORK PRACTICES Working On Or Near Energized Electrical Equipment CAT A-1 SOP #4 SUNCOR ENERGY PRODUCTS DISTRIBUTION TERMINAL OPERATING MANUAL STANDARD OPERATING PROCEDURE SAFE-WORK PRACTICES Working On Or Near Energized Electrical Equipment Lifesaving Rules Supporting Document Verify

More information

Recent changes in workplace safety regulations have heightened the awareness of hazards associated with electrical arcs.

Recent changes in workplace safety regulations have heightened the awareness of hazards associated with electrical arcs. Recent changes in workplace safety regulations have heightened the awareness of hazards associated with electrical arcs. The hazard level must be quantified and workers properly protected before entering

More information

Preview to the 2018 NFPA 70E, the Standard for Electrical Safety in the Workplace

Preview to the 2018 NFPA 70E, the Standard for Electrical Safety in the Workplace Preview to the 2018 NFPA 70E, the Standard for Electrical Safety in the Workplace Preview to the 2018 NFPA 70E, the Standard for Electrical Safety in the Workplace Technical Committee Members James Dollard,

More information

XXIV Commercial / Industrial Companies Energized Electrical / Hot Work Program

XXIV Commercial / Industrial Companies Energized Electrical / Hot Work Program XXIV Energized Electrical / Hot Work Program 24-1 September 12, 2011 Dear IEC Members: The Energized Electric/Hot Work Safety Programs were developed by IES (Integrated Electrical Services) and approved

More information

NFPA 70E Policies and Best Practices

NFPA 70E Policies and Best Practices NFPA 70E Policies and Best Practices Overview o Understand Compliance Requirements o Provide guidelines for a safe work environment o Effectively communicate policies to employees and customers o Express

More information

Electrical Safety Program

Electrical Safety Program Electrical Safety Program Last Revised Date: 8/2017 Last Reviewed Date: Effective Date: 1/2008 Applies to: Employees, Faculty, Students, Others For More information Contact: EHS, Occupational Health and

More information

Title: NFPA 70E Effective Date: 12/8/2014 Control Number: THG_0053 Revision Number: 1 Date: 10/26/2015 Annual Review Completed: 5/13/2015 NFPA 70E

Title: NFPA 70E Effective Date: 12/8/2014 Control Number: THG_0053 Revision Number: 1 Date: 10/26/2015 Annual Review Completed: 5/13/2015 NFPA 70E Title: NFPA 70E Effective Date: 12/8/2014 Control Number: THG_0053 Revision Number: 1 Date: 10/26/2015 Annual Review Completed: 5/13/2015 CONTENTS NFPA 70E I. INTRODUCTION II. PURPOSE III. SCOPE IV. ENGINEERING

More information

Lockout / Tagout Safety Program

Lockout / Tagout Safety Program Lockout / Tagout Safety Program Prepared by: The Ohio State University Environmental Health and Safety Occupational Safety & Industrial Hygiene 1314 Kinnear Road Columbus, OH 43212-1168 614-292-1284 Phone

More information

SUBJECT: SAFE WORK PRACTICES CHECKLIST FOR LOW VOLTAGE ELECTRICIANS REVISION September 15, Area Checklist Items 2600SEG131 Check ( or NA)

SUBJECT: SAFE WORK PRACTICES CHECKLIST FOR LOW VOLTAGE ELECTRICIANS REVISION September 15, Area Checklist Items 2600SEG131 Check ( or NA) HUMN RESOURCES DEPRTMENT SFETY ND INDUSTRIL HYGIENE UNIT FOR USE WITH SFE WORK PRCTICES FOR LOW VOLTGE ELECTRICINS STNDRD 2600SEG131 ND NNEX SFE WORK PRCTICES CHECKLIST FOR LOW VOLTGE ELECTRICINS 1 OF

More information

Personal Protective Equipment. Individual Unit Function: Safety Procedure No.: SOP-0147 Page: 1 of 9

Personal Protective Equipment. Individual Unit Function: Safety Procedure No.: SOP-0147 Page: 1 of 9 Procedure No.: SOP-0147 Page: 1 of 9 1. PURPOSE This procedure describes the minimum requirements concerning personal protective equipment for personnel who are exposed to areas or tasks where hazards

More information

Innovative Techniques for Mitigating Arc Flash Exposure

Innovative Techniques for Mitigating Arc Flash Exposure Innovative Techniques for Mitigating Arc Flash Exposure Presented at MEMSA 2009 Annual Meeting & Technical Symposium 2007 Eaton Corporation. All rights reserved. INTRODUCTION. As more and more industries

More information

COMPANY SAFETY PROGRAM

COMPANY SAFETY PROGRAM COMPANY SAFETY PROGRAM Terminal-Andrae Inc. conducts their operations so that injuries to people, damage to the property and/or the environment will be avoided. Every effort will be made to prevent accidents.

More information

NECA Personal Protective Equipment (PPE) Selector

NECA Personal Protective Equipment (PPE) Selector NECA Personal Protective Equipment (PPE) Selector Objectives Explain why electrical contractors should follow the precautions set forth in NFPA 70E List the hazards which demonstrate why an arc flash risk

More information

POWER PLANT RELAY REPLACEMENT DELIVERABLE ARC FLASH

POWER PLANT RELAY REPLACEMENT DELIVERABLE ARC FLASH POWER PLANT RELAY REPLACEMENT DELIVERABLE ARC FLASH ISU Senior Design Group: Dec15-22 Dan Dye Project Web Site: http://dec1522.sd.ece.iastate.edu/ Project Sponsor: CIPCO Project Advisor: Professor Mani

More information

Doc No: ELECTRIC Midland Engineering Co., Inc. Initial Issue Date 12/14/15 Safety Management System

Doc No: ELECTRIC Midland Engineering Co., Inc. Initial Issue Date 12/14/15 Safety Management System Revision Page 1 of PURPOSE The purpose is to eliminate unsafe conditions involving electrical equipment and tools, including faulty insulation, improper grounding, loose electrical connections, defective

More information

Major Changes. Standard. TECH TOPIC standards and. By Peter Walsh, PE

Major Changes. Standard. TECH TOPIC standards and. By Peter Walsh, PE Major Changes to NFPA 70E Standard 2015 Edition TECH TOPIC standards and codes note 5 By Peter Walsh, PE Industrial Solutions Engineer Introduction NFPA 70E, Standard for Electrical Safety in the Workplace,

More information

Chapter 7 - Electrical Safety

Chapter 7 - Electrical Safety Chapter 7 Electrical Safety Chapter 7 - Electrical Safety Policy It is the policy of Hayward Electric to take every reasonable precaution in the performance of work to protect the health and safety of

More information

Electrical Safety Program

Electrical Safety Program Electrical Safety Program 6300-3.1 Associated OHS Process: General Industry and Construction Safety The master copy of this document resides in electronic format. Printed copies of this document are for

More information

Safe Schools: A Health and Safety Check

Safe Schools: A Health and Safety Check Name of School: Optional Information Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Use of Electrical Equipment Self-Inspection Checklist Guidelines: This checklist covers

More information

Electrical Hazard Assessments: OSHA & The NFPA 70E?

Electrical Hazard Assessments: OSHA & The NFPA 70E? Electrical Hazard Assessments: OSHA & The NFPA 70E? AWEA Health & Safety Mike Moore Key Learning Objectives Key Learning's Statistical Electrical Incidents & Injuries What Does OSHA Want? A quick Glimpse

More information

Electrical Safety Program

Electrical Safety Program Safety Manual Page 1 of 53 1. Purpose A. The purpose of the USPL (the Program ) is to provide a practical, safe working environment for USPL employees and contractors regarding the hazards arising from

More information

Safety Meeting Topic #6 Working Around /On Energized Equipment

Safety Meeting Topic #6 Working Around /On Energized Equipment Safety Meeting Topic #6 Working Around /On Energized Equipment Employees shall become familiar with the following general guidelines: 1. Only qualified personnel shall work on electrical equipment, systems,

More information

Individual employees are responsible for their own and their co-workers' safety. This means:

Individual employees are responsible for their own and their co-workers' safety. This means: Chapter 7 - Electrical Safety Chapter 7 Electrical Safety Policy It is the policy of Hayward Electric to take every reasonable precaution in the performance of work to protect the health and safety of

More information

Hazardous Energy Control (Lockout-Tagout)

Hazardous Energy Control (Lockout-Tagout) Hazardous Energy Control (Lockout-Tagout) The purpose of this program is to prevent inadvertent operation or energization of machines, equipment, or processes in order to protect employees and establish

More information

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL

U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL SAFE -14 Page 1 of 8 U.S. CONCRETE, INC. SAFETY POLICY and PROCEDURE MANUAL FUNCTION Safety TOPIC Hotwork Permit Program OBJECTIVE(S): GENERAL POLICY: To provide a work atmosphere that is conducive to

More information

Welding With Arc Welding Equipment

Welding With Arc Welding Equipment Optional Information Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Welding With Arc Welding Equipment Self Inspection Checklist Guidelines: This checklist

More information

Hot Work Program. University of Wisconsin-Platteville Reviewed 4/2016

Hot Work Program. University of Wisconsin-Platteville Reviewed 4/2016 Hot Work Program University of Wisconsin-Platteville Reviewed 4/2016 The purpose of the Hot Work Program is to establish safety procedures for employees, contractors, and subcontractors engaging in any

More information

Helping Employers. Protect Workers. from Arc Flash and other Electrical Hazards

Helping Employers. Protect Workers. from Arc Flash and other Electrical Hazards Helping Employers Protect Workers from Arc Flash and other Electrical Hazards Why an Effective Safety Program is Essential The Hazards are Real Electrical Shocks National Safety Council statistics show

More information

ASSOCIATED DOCUMENTS:

ASSOCIATED DOCUMENTS: Medtronic ENT Rev. C Ref. 9.0 Page 1 of 5 1.0 PURPOSE: 1.1. The personal protective equipment (PPE) program is provided to decrease exposure to job-related hazards. This program identifies responsibilities,

More information

Electrical Safety. Unqualified Worker

Electrical Safety. Unqualified Worker Electrical Safety Unqualified Worker Session Objectives Understand the hazards of electricity Identify and avoid common electrical hazards Follow safe work practices around electrical equipment How Does

More information

The following were determined to be confined spaces; they may not be permit required that employees of the Division of Facilities may encounter:

The following were determined to be confined spaces; they may not be permit required that employees of the Division of Facilities may encounter: Confined Space Classifications The following were determined to be confined spaces; they may not be permit required that employees of the Division of Facilities may encounter: Utility Tunnels, Crawl Spaces,

More information

SECTION 10 ELECTRICAL SAFETY

SECTION 10 ELECTRICAL SAFETY SECTION 10 ELECTRICAL SAFETY 10.1 Electrical Safety - Work Practices 10.2 Lockout / Tagout Procedure Revised: May 2012, March 2011 Updated: November 2017 Reviewed: November 2008 Revised: February 2003

More information