1 African Development Bank Group African Development Bank's Field Office in Abuja, Nigeria LOT 2: VOL 3-2 BILLS OF QUANTITIES: MECHANICAL (HVAC SERVICES) WORKS Prepared by Interstate Architects Ltd. In Conjunction with: IAA Associates Ltd. KOA Associates Ltd. & Construction Economists Partnership Ltd.

2 BILL No. 1 - PLANTS AND EQUIPMENT Supply and install the following plants and equipment. Further schedules of some of the items are given at the end of this bill. Tenderer is expected to be familiar with the specifed manufacturers and is to submit appropriate brochures of the specified items (or an equivalent product of another acceptable manufacturer as shall be agreed with the Client and Consultants. FIXED 1 Chillers Unit shall be complete with heat recovery accessories. Allow for anti-corrosion treatment. Controls shall be interfaced intio a BMS system. E.g. Trane air cooled helical rotary chillers (RTAD 085) or approved equal Chiller 0-1&2 (duty and duty) cooling cap: 255kW temp diff: 6.0 o ambient: 40oC DB, 28 0 C WB 2 Nos 2 Chilled Water Circulating Pumps e.g Pullen, Grundfos or approved equal Constant flow pimary circuit pumps. Pumps shall be the vertical type mounted indoors (IP55 rating) P 0-1&2 (duty/standby) kPa 2 no 3 Make-up and pressurisation unit comprising pumps, tank, pneumatic vessel, accessories and interconnecting pipework as detailed in drawing. 1 set 4 Chemical dosing unit comprising of tank, dosing pump and all accessories 1 No 5 Line pressurisation vessel - chilled water system 1 No Page 1-1 To Bill Collection IAL AfDB BOQ HVAC 1

3 BILL No. 1 (Cont'd) - PLANTS AND EQUIPMENT FIXED 6 Allow for anti-vibration mounting of all equipment. sum Air Handling Units (e.g. Trane CLCP or approved equal) Modular double skin chilled water air handlers, coil shall be copper/aluminum Air handling configuration shall follow the following modules: I - Inlet plenum M - Mixing box P - Flat pleated panel filter (rated F7) B - Bag filter (rated F9) C - Cooling coil (chilled water) A - Access Box F - Centrifugal fan unit O - Outlet plenum Air flow rates are nominal values. The AHU shall be rated an extra 5% to cater for duct leakage and balancing. 7 AHU 0-1 (Horizontal) 1 No Config: M-P-B-C-A-F airflow: l/s cooling load: 43.08kW ESR: 428 Pa 8 AHU 5-1 & 2 (Vertical) - duty/duty 2 No Config: I-P-C-A-F airflow: l/s cooling load: kW ESR: 890 Pa Page 1-2 To Bill Collection IAL AfDB BOQ HVAC 2

4 BILL No. 1 (Cont'd) - PLANTS AND EQUIPMENT FIXED Extract Fan e.g Flakt Woods or approved equal. In-duct aerofoil fans are to be mounted in acoustic insulated enclosures (boxes) and rated IP65. Fans shall be generally selected for speeds not exceeding 1500rpm except otherwise agreed with the Consultant. Break out noise (after allowing for acoustic insulation) shall not exceed 40dB Fans shall be duplicate operating on a duty/standby basis 9 TEF 6-1&2 (duty/standby) - Toilet extract Pa 2 Nos 10 EF 6-1&2 - Atrium ventilation Fans shall be rated 'flame proof' Pa 2 Nos Staircase pressurisation Fan e.g Flakt Woods or approved equal. In-duct aerofoil fans are to be mounted in acoustic insulated enclosures (boxes) and rated IP65. Fans shall be generally selected for speeds not exceeding 1500rpm except otherwise agreed with the Consultant. Break out noise (after allowing for acoustic insulation) shall not exceed 40dB Fans shall be duplicate operating on a duty/standby basis 11 SPF 6-1&2 (duty/standby) - escape stair pressurisation Pa 2 Nos Page 1-3 To Bill Collection IAL AfDB BOQ HVAC 3

5 BILL No. 1 (Cont'd) - PLANTS AND EQUIPMENT FIXED Computer Room Air conditioning units (CRAC 1-1&2) - duty/standby Units shall have DX coils and shall be complete with matching air cooled condensing units. Units shall be c/w all integral microprocessor controls for temperature and humidity, display unit, alarm indication. Units shall have autorestart facility. Provide dry contacts for connections to fire alarm system and BMS. Refrigerant shall be R410A or better (The option for electric reheat and humidifier shall be quoted seperately and shall be optional). Eg Airedale Logicool In-Rak (data centre unit) or approved equal. 12 CRAC 1-1&2 cooling cap: 26.20kW total, 25.75kW sens. airflow: 2326 l/s Refrigerant piping for CRAC units. Allow for insulation and sheating Condensate piping for CRAC units using 25mmDIA HDPE. Allow for insulation 2 No 13 Line pressurisation vessel - chilled water system 1 No 14 Allow for anti-vibration mounting of all equipment. Wall Extract Fan e.g Xpelair or approved equal. 15 EF Battery extract 36 l/s 1 No 16 EF Disabled Toilet 50 l/s 1 No COLLECTION pg 1-1 pg 1-2 pg 1-3 Page 1-4 pg 1-4 To Summary IAL AfDB BOQ HVAC 4

6 BILL No. 2/1 - VRF Installation Supply and install the following plants and equipment. Tenderer is expected to be familiar with the specifed manufacturers and is to submit appropriate brochures of the specified items (or an equivalent product of another acceptable manufacturer as shall be agreed with the Client and Consultants. FIXED Outdoor air-cooled VRF condensing units, capable of multiple indoor units and zone, with extended range refrigerant piping. Operating outdoor temperature is 40oC. High COP. Refrigerant shall be R410A. E.g. Daikin, LG, or approved equal. Note that the capacities stated below are for the combined floor load and are not additions of the individual capacities of the indoor units. 1 VRF 6-1 (serving ground floor) cap: 85.23kW 1 no 2 VRF 6-2 (serving first floor) cap: 56.03kW 1 no 3 VRF 6-3 (serving second floor) cap: 60.86kW 1 no 4 VRF 6-4 (serving third floor) cap: 61.69kW 1 no 5 VRF 6-5 (serving fourth floor) cap: 63.58kW 1 no 6 VRF 6-6 is for the future 5th floor development and is not measured in this developmental phase. Page 2/1 To Bill Collection IAL AfDB BOQ HVAC 1

7 BILL No. 2/2 - VRF Installation FIXED Indoor VRF Cassette Units (CAS) Ceiling mounted cassette coil unit, matched to outdoor unit, with galvanised sheeting treated for corrosion, 3-speed fan, integral condensate pump, easily accessible and cleanable EU4 filter with anti-bacterial and mildew treatment, connections for remote control of fan and space temperature, all mounting and fixing accessories. Unit shall have port for BMS signal connection. Include for unit cabled remote control and wall mounted thermostat/controller. NOTE: equipment selection shall be at low fan speed and entering condition of 23.0/16.4 o C (except otherwise indicated in the drawing schedules) GROUND FLOOR 1 CAS no Cooling cap: 2.99kW Nominal airflow: 186 l/s 2 CAS no Cooling cap: 2.99 kw Nominal airflow: 186 l/s 3 CAS no Cooling cap: 2.99kW Nominal airflow: 186 l/s 4 CAS no Cooling cap: 2.99kW Nominal airflow: 186 l/s 5 CAS no Cooling cap: 2.65kW Nominal airflow: 225 l/s 6 CAS no Cooling cap: 2.65kW Nominal airflow: 225 l/s 7 CAS no Cooling cap: 2.65kW Nominal airflow: 225 l/s Page 2/2-1 To Sub Collection IAL AfDB BOQ HVAC 2

8 BILL No. 2/2 (Cont'd) - VRF Installation FIXED Indoor VRF Cassette Units (CAS): ground floor 8 CAS no Cooling cap: 2.65kW Nominal airflow: 225 l/s 9 CAS no Cooling cap: 2.65kW Nominal airflow: 225 l/s 10 CAS no Cooling cap: 3.00kW Nominal airflow: 245 l/s 11 CAS no Cooling cap: 3.00kW Nominal airflow: 245 l/s 12 CAS no Cooling cap: 3.00kW Nominal airflow: 245 l/s 13 CAS no Cooling cap: 3.00kW Nominal airflow: 245 l/s 14 CAS no Cooling cap: 3.00kW Nominal airflow: 245 l/s 15 CAS no Cooling cap: 3.00kW Nominal airflow: 245 l/s 16 CAS no Cooling cap: 3.00kW Nominal airflow: 245 l/s 17 CAS no Cooling cap: 3.35kW Nominal airflow: 260 l/s 18 CAS no Cooling cap: 3.35kW Nominal airflow: 260 l/s Page 2/2-2 To Sub Collection IAL AfDB BOQ HVAC 3

9 BILL No. 2/2 (Cont'd) - VRF Installation Indoor VRF Cassette Units (CAS): ground floor 19 CAS no Cooling cap: 3.35kW Nominal airflow: 260 l/s 20 CAS no Cooling cap: 3.35kW Nominal airflow: 260 l/s FIXED 21 CAS no Cooling cap: 3.35kW Nominal airflow: 260 l/s 22 CAS no Cooling cap: 3.35kW Nominal airflow: 260 l/s 23 CAS no Cooling cap: 2.15kW Nominal airflow: 188 l/s 24 CAS no Cooling cap: 2.15kW Nominal airflow: 188 l/s 25 CAS no Cooling cap: 2.15kW Nominal airflow: 188 l/s 26 CAS no Cooling cap: 2.32kW Nominal airflow: 175 l/s 27 CAS no Cooling cap: 1.80kW Nominal airflow: 136 l/s 28 CAS no Cooling cap: 2.72kW Nominal airflow: 252 l/s 29 CAS no Cooling cap: 3.00kW Nominal airflow: 225 l/s 30 CAS no Cooling cap: 2.63kW Nominal airflow: 228 l/s SUB-COLLECTION page 2/2-1 page 2/2-2 page 2/2-3 Page 2/2-3 To Bill Collection (ground floor CAS) IAL AfDB BOQ HVAC 4

10 BILL No. 2/3 - VRF Installation FIXED Indoor VRF Cassette Units (CAS): first floor 1 CAS no Cooling cap: 2.40kW Nominal airflow: 200 l/s 2 CAS no Cooling cap: 2.40kW Nominal airflow: 200 l/s 3 CAS no Cooling cap: 3.67kW Nominal airflow: 335 l/s 4 CAS no Cooling cap: 3.67kW Nominal airflow: 335 l/s 5 CAS no Cooling cap: 2.43kW Nominal airflow: 220 l/s 6 CAS no Cooling cap: 2.43kW Nominal airflow: 220 l/s 7 CAS no Cooling cap: 2.95kW Nominal airflow: 258 l/s 8 CAS no Cooling cap: 2.95kW Nominal airflow: 258 l/s 9 CAS no Cooling cap: 1.76kW Nominal airflow: 165 l/s 10 CAS no Cooling cap: 4.17kW Nominal airflow: 345 l/s 11 CAS no Cooling cap: 4.17kW Nominal airflow: 345 l/s Page 2/3-1 To Sub Collection IAL AfDB BOQ HVAC 5

11 BILL No. 2/3 ( Cont'd) - VRF Installation FIXED Indoor VRF Cassette Units (CAS): first floor 12 CAS no Cooling cap: 2.84kW Nominal airflow: 243 l/s 13 CAS no Cooling cap: 3.48kW Nominal airflow: 307 l/s 14 CAS no Cooling cap: 3.48kW Nominal airflow: 307 l/s 15 CAS no Cooling cap: 3.48kW Nominal airflow: 307 l/s 16 CAS no Cooling cap: 3.48kW Nominal airflow: 307 l/s 17 CAS no Cooling cap: 3.48kW Nominal airflow: 307 l/s 18 CAS no Cooling cap: 1.91kW Nominal airflow: 172 l/s 19 CAS no Cooling cap: 0.88kW Nominal airflow: 76 l/s SUB-COLLECTION page 2/3-1 page 2/3-2 Page 2/3-2 To Bill Collection (first floor CAS) IAL AfDB BOQ HVAC 6

12 BILL No. 2/4 - VRF Installation FIXED Indoor VRF Cassette Units (CAS): second floor 1 CAS no Cooling cap: 3.58kW Nominal airflow: 318 l/s 2 CAS no Cooling cap: 3.58kW Nominal airflow: 318 l/s 3 CAS no Cooling cap: 3.58kW Nominal airflow: 318 l/s 4 CAS no Cooling cap: 3.58kW Nominal airflow: 318 l/s 5 CAS no Cooling cap: 3.58kW Nominal airflow: 318 l/s 6 CAS no Cooling cap: 3.58kW Nominal airflow: 318 l/s 7 CAS no Cooling cap: 1.79kW Nominal airflow: 166 l/s 8 CAS no Cooling cap: 1.76kW Nominal airflow: 165 l/s 9 CAS no Cooling cap: 4.17kW Nominal airflow: 345 l/s 10 CAS no Cooling cap: 4.17kW Nominal airflow: 345 l/s 11 CAS no Cooling cap: 3.04kW Nominal airflow: 278 l/s Page 2/4-1 To Sub Collection IAL AfDB BOQ HVAC 7

13 BILL No. 2/4 (Cont'd) - VRF Installation FIXED Indoor VRF Cassette Units (CAS): second floor 12 CAS no Cooling cap: 3.04kW Nominal airflow: 278 l/s 13 CAS no Cooling cap: 3.46kW Nominal airflow: 300 l/s 14 CAS no Cooling cap: 3.05kW Nominal airflow: 271 l/s 15 CAS no Cooling cap: 3.05kW Nominal airflow: 271 l/s 16 CAS no Cooling cap: 3.05kW Nominal airflow: 271 l/s 17 CAS no Cooling cap: 3.05kW Nominal airflow: 271 l/s 18 CAS no Cooling cap: 3.05kW Nominal airflow: 271 l/s 19 CAS no Cooling cap: 1.62kW Nominal airflow: 145 l/s 20 CAS no Cooling cap: 1.08kW Nominal airflow: 90 l/s SUB-COLLECTION page 2/4-1 page 2/4-2 Page 2/4-2 To Bill Collection (second floor CAS) IAL AfDB BOQ HVAC 8

14 BILL No. 2/5 - VRF Installation FIXED Indoor VRF Cassette Units (CAS): third floor 1 CAS no Cooling cap: 3.35kW Nominal airflow: 297 l/s 2 CAS no Cooling cap: 3.35kW Nominal airflow: 297 l/s 3 CAS no Cooling cap: 3.35kW Nominal airflow: 297 l/s 4 CAS no Cooling cap: 3.35kW Nominal airflow: 297 l/s 5 CAS no Cooling cap: 3.35kW Nominal airflow: 297 l/s 6 CAS no Cooling cap: 3.35kW Nominal airflow: 297 l/s 7 CAS no Cooling cap: 3.35kW Nominal airflow: 297 l/s 8 CAS no Cooling cap: 1.76kW Nominal airflow: 165 l/s 9 CAS no Cooling cap: 4.17kW Nominal airflow: 345 l/s 10 CAS no Cooling cap: 4.17kW Nominal airflow: 345 l/s 11 CAS no Cooling cap: 3.09kW Nominal airflow: 266 l/s Page 2/5-1 To Sub Collection IAL AfDB BOQ HVAC 9

15 BILL No. 2/5 (Cont'd) - VRF Installation FIXED Indoor VRF Cassette Units (CAS): third floor 12 CAS no Cooling cap: 3.20kW Nominal airflow: 283 l/s 13 CAS no Cooling cap: 3.20kW Nominal airflow: 283 l/s 14 CAS no Cooling cap: 3.20kW Nominal airflow: 283 l/s 15 CAS no Cooling cap: 3.20kW Nominal airflow: 283 l/s 16 CAS no Cooling cap: 3.20kW Nominal airflow: 283 l/s 17 CAS no Cooling cap: 3.20kW Nominal airflow: 283 l/s 18 CAS no Cooling cap: 3.20kW Nominal airflow: 283 l/s 19 CAS no Cooling cap: 1.57kW Nominal airflow: 140 l/s 20 CAS no Cooling cap: 1.08kW Nominal airflow: 90 l/s SUB-COLLECTION page 2/5-1 page 2/5-2 Page 2/5-2 To Bill Collection (third floor CAS) IAL AfDB BOQ HVAC 10

16 BILL No. 2/6 - VRF Installation FIXED Indoor VRF Cassette Units (CAS): fourth floor 1 CAS no cooling cap: 2.94kW Nominal airflow: 259 l/s 2 CAS no cooling cap: 2.94kW Nominal airflow: 259 l/s 3 CAS no cooling cap: 2.94kW Nominal airflow: 259 l/s 4 CAS no cooling cap: 2.94kW Nominal airflow: 259 l/s 5 CAS no Cooling cap: 3.20kW Nominal airflow: 288 l/s 6 CAS no Cooling cap: 3.20kW Nominal airflow: 288 l/s 7 CAS no Cooling cap: 3.20kW Nominal airflow: 288 l/s 8 CAS no Cooling cap: 3.20kW Nominal airflow: 288 l/s 9 CAS no Cooling cap: 1.99kW Nominal airflow: 187 l/s 10 CAS no Cooling cap: 4.20kW Nominal airflow: 348 l/s 11 CAS no Cooling cap: 4.20kW Nominal airflow: 348 l/s Page 2/6-1 To Sub Collection IAL AfDB BOQ HVAC 11

17 BILL No. 2/6 (Cont'd) - VRF Installation FIXED Indoor VRF Cassette Units (CAS): fourth floor 12 CAS no Cooling cap: 3.12kW Nominal airflow: 269 l/s 13 CAS no Cooling cap: 3.24kW Nominal airflow: 287 l/s 14 CAS no Cooling cap: 3.24kW Nominal airflow: 287 l/s 15 CAS no Cooling cap: 3.24kW Nominal airflow: 287 l/s 16 CAS no Cooling cap: 3.24kW Nominal airflow: 287 l/s 17 CAS no Cooling cap: 3.24kW Nominal airflow: 287 l/s 18 CAS no Cooling cap: 3.24kW Nominal airflow: 287 l/s 19 CAS no Cooling cap: 3.24kW Nominal airflow: 287 l/s 20 CAS no Cooling cap: 1.59kW Nominal airflow: 142 l/s 21 CAS no Cooling cap: 1.24kW Nominal airflow: 115 l/s SUB-COLLECTION page 2/6-1 page 2/6-2 Page 2/6-2 To Bill Collection (fourth floor CAS) IAL AfDB BOQ HVAC 12

18 BILL No. 2/7 - VRF Installation Accessories Supply and install accessories associated with the VRF units indicated above FIXED 1 Remote control and thermostat unit incorporating 3-speed fan control. Allow for cabling - ground floor units - first floor units - second floor units - third floor units - fourth floor units Instrumentation and controls 2 Supply and install system logic-based electrical and auto-control panel. Control unit to include for desktop PC and monitor (mounted in the 5th floor plant room). Panel shall allow for all electrical power protections - phase failure, under/over current, surge protection, etc. Include for step down transformer for controllers all to give a fully functional system 1 no 3 Allow for control cabling from all indoor and outdoor units to the control panel - outdoor units - ground floor units - first floor units - second floor units - third floor units - fourth floor units 4 Allow for power cabling to outdoor units. Include for outdoor mounted local isolators. 5 Allow for cable fixing, hangers, conduits, supports Page 2/7-1 To Bill Collection IAL AfDB BOQ HVAC 13

19 BILL No. 2/7 (Cont'd) - VRF Installation FIXED Refrigerant piping 6 Supply and install all refrigerant piping using copper (BS 2871). The tenderer shall submit computer based pipe sizing calculations appropriate to the product being tendered and a breakdown of the costings for each floor extended and totalled to the figures inserted in this BOQ. The refrigerant installation shall be from the roof mounted outdoor units to the indoor units on each floor. Rates shall include for all fittings and accessories - ground floor units - first floor units - second floor units - third floor units - fourth floor units 7 Supply and install insulations to all refrigerant piping using armaflex tubing (or approved equivalent) of appropriate thickness. Rates shall include for all fittings and accessories - ground floor units - first floor units - second floor units - third floor units - fourth floor units Page 2/7-2 To Bill Collection IAL AfDB BOQ HVAC 14

20 BILL No. 2/7 (Cont'd) - VRF Installation FIXED 8 Condensate piping Supply and install all condensate piping to the indoor units using HDPE piping. The layout shall be as indicated in the design drawings. Rates shall include for all fittings and accessories. Rates shall includes for 20mm thick armaflex (or approved equal) insulation tubing. ground floor units 25mm dia 62 m 50mm dia 144 m 80mm dia (stack for entire installation and connection to drain channels) 72 m first floor units 25mm dia 46 m 50mm dia 96 m second floor units 25mm dia 46 m 50mm dia 96 m third floor units 25mm dia 44 m 50mm dia 96 m fourth floor units 25mm dia 44 m 50mm dia 96 m 9 Allow for pipe fixing, brackets, hangers, supports to sub collection COLLECTION page 2/7-1 page 2/7-2 page 2/7-3 Page 2/7-3 To Bill Collection IAL AfDB BOQ HVAC 15

21 BILL No. 2 - VRF Installation FIXED BILL COLLECTION bill 2/1 bill 2/2 bill 2/3 bill 2/4 bill 2/5 bill 2/6 bill 2/7 To Summary IAL AfDB BOQ HVAC 16

22 BILL No. 3 - DUCTWORK FIXED Supply and install the following (refer to drawing and specification for details). All air diffusion units shall be extruded aluminum (except otherwise indicated) and shall be to RAL colour to be approved by the architect Ductwork 1 Galvanised sheet metal ductwork (using appropriate guages as specified) m 2 2 Provided for insulation to duct using 25mm foil faced mineral fibre insulation and vapour barrier. 978 m 2 3 Provided for internal thermal and acoustic duct liner to duct above using 50mm thick non fibre medical grade insulation and vapour barrier with anti-bacterial and anti-fungal treatment e.g. Armaflex/Armacell, KFlexUSA or approved equal. Include for fasterners, etc Insulations within plantrooms shall be internal. Also insulations up to 10m from (airhandling) AHUs shall be internal. 420 m 2 4 Supply Diffuser (SD) ceiling mounted. Units shall be square face adjustable multi-louvre type with round neck (or square neck) supply. Units shall be complete with iris (or opposed blade) damper. E.g. GDL, Trox or approved equivalent. Neck diameters are indicated below 150 dia 103 nos 200 dia dia 1 5 Sidewall Supply Diffuser (SWD) Units shall have double deflection grilles c/w opposed blade dampers. E.g. GDL, Trox or approved equivalent 300 x nos 900 x " 6 Return Grille (RG) ceiling mounted. Units shall be rectangular face adjustable egg crate type. Units shall be complete with opposed blade damper. E.g. GDL, Trox or approved equivalent 1200 x no Page 3-1 To Conclusions IAL AfDB BOQ HVAC 1

23 BILL No. 3 (Cont'd) - DUCTWORK FIXED 7 Sidewall Air Jet Grille (AJG) High capacity supply air jets to have concentric rings assembled with a pivoting eyeball adjustment c/w opposed blade dampers. E.g. GDL J frame, Trox or approved equivalent 350 x 350 (single jet) 4 nos 8 Extract Grille (EG) ceiling mounted. Units shall be rectangular face adjustable egg crate type. Units shall be complete with opposed blade damper. E.g. GDL, Trox or approved equivalent 150 x nos 10 Flow control / Balancing Dampers single or multi leaf. E.g GDL, Trox or approved equivalent Allow for the provision of balancing dampers as indicated on drawing and/or specification and/or schedules 11 Door Transfer Grille non-vision 600 x Nos 12 Fire Dampers 2hr rating c/w fusible link,. E.g GDL, Trox or approved equivalent Allow for the provision of fire dampers as indicated on drawing and/or specification, schedules 200 x nos 300 x " 300 x " 400 x " 500 x " 600 x " 800 x " 900 x " 950 x " 150dia 5 nos Page 3-2 To Conclusions IAL AfDB BOQ HVAC 2

24 BILL No. 3 (Cont'd) - DUCTWORK FIXED 13 Allow for clean outs, test holes and access doors. 14 Allow for support, brackets, vibration dampers etc. 15 Allow for flexible duct connectors from duct to ceiling terminals. Page 3-3 To Conclusions CONCLUSION pg 3-1 pg 3-2 pg 3-3 To Summary IAL AfDB BOQ HVAC 3

25 BILL No. 4 - CHILLED WATER PIPING FIXED Supply and install the following Pipework shall be black mild steel to BS 1387 Class C Heavy Grade. Large diameter pipes shall be grooved. 1 Pipes 25mm 6 m 32mm 6 m 50mm 18 m 100mm 54 m 125mm 216 m Bend 25mm 6 nos 32mm 6 50mm mm mm Bend 100mm 4 125mm 14 4 Tee 125mm 10 5 Isolating Ball Valve 50mm 2 Page 4-1 To Conclusions IAL AfDB BOQ HVAC 1

26 BILL No. 4 (Cont'd) - CHILLED WATER PIPING FIXED 6 Isolating Butterfly Valve 100mm 6 125mm 8 7 Double Regulating Valve (c/w test points and seals) 50mm 1 100mm 6 125mm Way Modulating Valves (c/w motor actuator) 50mm 1 100mm 2 10 Check (NRV) Valve 32mm 1 125mm 2 11 Strainer (Line) 50mm 1 100mm 4 125mm 2 Page 4-2 To Conclusions IAL AfDB BOQ HVAC 2

27 BILL No. 4 (Cont'd) - CHILLED WATER PIPING FIXED 12 Flexible Connector 50mm 2 100mm 8 125mm 4 13 Flange (c/w) gasket 50mm mm mm End Flange (Cap) 125mm 2 15 Capped Flushing Tee 25mm 5 nos 16 Drain Cock 25mm 5 nos 17 Valved Flushing Inlet 50mm 2 nos 18 Safety Relief Valve 10bar setting 2 nos 19 Automatic Air Valve (AAV) 5 no 20 Flow Switch 1 no 21 Air Eliminator 5 no 22 Test point (sealed) 6 no 23 Pressure guage (0-15bar) c/w cock 10 no Page 4-3 To Conclusions IAL AfDB BOQ HVAC 3

28 BILL No. 4 (Cont'd) - CHILLED WATER PIPING FIXED 24 Thermometer (Dial type 150mm) 10 no 25 Miscellaneous Items Union, connectors, nipples, 135o bends, etc Bracket, hangers, supports, etc 26 Thermal Insulation (using preformed rigid mineral wool insulation or armaflex tubings. Allow for vapour seal) - thickness as specified but minimum 50mm 25mm 6 m 32mm 6 m 50mm 18 m 100mm 54 m 125mm 216 m 27 Carry out resin protective coating on pipes installed in plantrooms, risers and external. 25mm 6 m 32mm 6 m 50mm 18 m 100mm 54 m 125mm 216 m Page 4-4 To Conclusions CONCLUSION pg 4-1 pg 4-2 pg 4-3 pg 4-4 To Summary IAL AfDB BOQ HVAC 4

29 BILL No. 5 - CONDENSATE PIPING (for chilled water) FIXED Supply and install the following Pipework shall be HDPE. All condnsate pipes shall be appropriately insulated. 1 Pipe 50mm mm 48 2 Bend 50mm 6 100mm 2 3 Tee 50mm 2 100mm 1 4 Trap Connections 50mm (for AHUs) 3 5 Turndish 100mm 2 nos 6 Miscellaneous Items Brackets, anchors, etc Flanges, gaskets, sockets, reducers, etc 7 Thermal Insulation using 20mm armaflex,, TO SUMMARY IAL AfDB BOQ HVAC 1

30 AfDB NGFO HAVC SYSTEM BOQ BILL No. 6 - INSTRUMENTATIONS AND CONTROL Supply and install the following. Refer to drawing, design report and specification for details FIXED 1 Thermostat duct 2 nos 2 Temperature Gauge (pipe mounted) - dial type 2 nos 3 Test point with cock 10 nos 5 Flow Switch 1 No 6 Differential Pressure Switch 3 Nos 7 Duct mounted dial thermometer 2 Nos 8 Duct mounted dial pressure gauge 2 Nos 9 Smoke Detector Probe 4 Nos 10 Control cabling, terminator, etc Lot 11 CO 2 Monitor (e.g Greystone Energy Systems) - duct mounted 12 Control Panel The controls shall be fully digital. Allow for control panel and system as detailed in the specifications, schedules and drawings. Include for all electrical control elements including the step-down transformer, (230/24 VAC), relays, switches, contactors, timers, including all current and voltage protective devices, e.t.c to give a fully function system. Note provisions for future upgrade. System shall be integrated into the building BMS 13 Control cabling Allow for control cabling to connect all controlled plants and the control panel. Rates to include for termination items. 14 Electrical Power cabling Allow for power cabling from the control panel and/or local distribution panel to all item of equipment for final connections. Provide appropriate termination devices. Only wireways shall be provided by others. 15 Local isolators to all items of equipment (some shall be suitable for outdoor installation) 1 nos 1 nos Page 6-1 To Conclusion IAL AfDB BOQ HVAC 1

31 AfDB NGFO HAVC SYSTEM BOQ BILL No. 6 (Cont'd) - INSTRUMENTATIONS AND CONTROL FIXED 16 Allow for equipontential bonding of the equipment 17 Allow for brackets, mountings, pads. 18 Allow for linkage to the building BMS including provisions for cabling 19 Allow for linkage to the building fire alarm panel including provisions for cabling Page To Conclusion CONCLUSION pg 6-1 pg 6-2 To Summary.... IAL AfDB BOQ HVAC 2

32 AfDB NGFO HAVC SYSTEM BOQ BILL NO 1 PLANTS& EQUIPMENT 2 VRF INSTALLATION 3 DUCTWORK 4 CHILLED WATER PIPING 5 CONDENSATE 6 INSTRUMENTATIONS & CONTROLS GENERAL SUMMARY OF BILLS SUB-.. IAL AfDB BOQ HVAC 1

Uniflair LE TDAR-TUAR

Uniflair LE TDAR-TUAR Uniflair LE TDAR-TUAR Direct Expansion air-cooled units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDAR) >

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119 Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Models: EPS Single Pump EPT Twin Pump EPS-HP EPT-HP Single Pump High Pressure Twin Pump High Pressure

More information

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G Data sheet Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G EN 215 Application RA2000 013G2910 Built-in sensor RA2000 013G2920 tamperproof RA2000 013G5062 remote temperature

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary

More information

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G Data sheet Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G Application RA2000 013G2910 Built-in sensor RA2000 013G2920 tamperproof RA2000 013G5062 remote temperature adjuster

More information

Ducted Reverse Cycle Air Conditioning of Distinction

Ducted Reverse Cycle Air Conditioning of Distinction Ducted Reverse Cycle Air Conditioning of Distinction Transforming global energy-efficiency into an art form! The Braemar advantage Braemar ducted reverse cycle air conditioners are brought to you by Seeley

More information

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION OCT2010 STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 020 87833050

More information

Check with local zoning official for property line distance requirements.

Check with local zoning official for property line distance requirements. RESIDENTIAL POOL PLAN SUBMITTAL GUIDELINES The following guidelines are intended to assist municipal residents with the permit acquisition process with regard to pools, spas and hot tubs for single family

More information

Remotely-installed Hydraulic Module

Remotely-installed Hydraulic Module Remotely-installed Hydraulic Module HDM 1.1-2.2 Single or twin pump ACC-PRC001E-GB Table of Contents Application Considerations Unit sizing...4 Unit placement... 4 Minimum water volume... 4 Selection Procedure...5

More information

CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature

CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature Thermostats CTC 1000 Series One-Pipe, Pneumatic Room Thermostat, Single Temperature Description The CTC 1000 series room thermostats are for use in HVAC systems for the control of pneumatic valves and

More information

Air Differentail Pressure Switch

Air Differentail Pressure Switch Page 1 of 5 PA-DPS-8x Air Differentail Pressure Switch Features: Benefits: Close switching differential Duct fixing kit included Switching point easily adjusted with scale in Pascals Conduit entry can

More information

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200

Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Specification Bulletin (rev.01) Series CH4200 Chemical Feed Equipment Floor-Mounted Gas Dispenser - Series CH4200 Easy, fast& accurate digital with 11 points calibration Laser sensor offering actual feed

More information

WaterSource Heat Pump Hose Kit Performance Specification-Summary

WaterSource Heat Pump Hose Kit Performance Specification-Summary WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo

More information

Ventam 85 Installation & Commissioning Instructions

Ventam 85 Installation & Commissioning Instructions Ventam Systems Ltd Unit D4 Seedbed Business Centre Vanguard Way Shoeburyness Essex SS3 9QY Phone 01702 382 307 Fax 01702 382 340 Ventam 85 Installation & Commissioning Instructions 1 General The Ventam

More information

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S06* Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100

Information Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100 Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

FMU4X, FMC4X FMU4P, FMC4P

FMU4X, FMC4X FMU4P, FMC4P ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply 4.1.1 General The primary function of a system for handling fuel oil is to transfer oil from the storage tank to the oil burner at specified conditions

More information

Evaporator (DX) Freon Applications 1 12 Tons MHF

Evaporator (DX) Freon Applications 1 12 Tons MHF Evaporator (DX) Freon Applications 1 12 Tons > > Used For small to medium freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client

More information

Automatic extractor outlet

Automatic extractor outlet L-07-2-01e Automatic extractor outlet Type HFA Contents Application Realisation Operation Safety instructions Contents Application Realisation Operation Safety instructions 2 Connection diagram Dimensions

More information

MEDICAL EQUIPMENT CATALOG

MEDICAL EQUIPMENT CATALOG THE MOST TRUSTED MEDICAL EQUIPMENT IN NORTH AMERICA MEDICAL EQUIPMENT CATALOG Total Components Including Bulk Oxygen Supply, Back up and Delivery Equipment Designs for High Pressure, Liquid or Bulk Applications

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S02 Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

C O L M A N. Air Distribution SWIRL DIFFUSERS DRS SERIES DRS SERIES

C O L M A N. Air Distribution SWIRL DIFFUSERS DRS SERIES DRS SERIES C O L M N ir Distribution E N G I N E E R E D I R P R O D U C T S SWIRL DIFFUSERS DRS SERIES DRS SERIES D SERIES SWIRL DIFFUSERS pplication The DRS, DQS, DCS and DSS series of fixed circular swirl diffusers

More information

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following: PART 1 GENERAL 1.1 DESCRIPTION.1 This section includes the supply, delivery and installation, testing and placement into operation of a gas chlorination system, and appurtenances as specified herein and

More information

The CWE / HWE-R Series: Overview. Frame and cabinet covering

The CWE / HWE-R Series: Overview. Frame and cabinet covering Table Of Contents The CWE / HWE-R Series: Overview...... 1 Frame and cabinet covering... 1 Refrigerant gas...... 2 Compressors...... 2 Condensers...... 2 Fans... 3 Evaporator...... 3 Refrigerant circuit......

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

System Pressure Manager Standard & System Pressure Manager Plus

System Pressure Manager Standard & System Pressure Manager Plus System Pressure Manager Standard & System Pressure Manager Plus Installation, Commissioning & Servicing Instructions Note: THESE INSTRUCTIONS MUST BE READ AND UNDERSTOOD BEFORE INSTALLING, COMMISSIONING,

More information

Pressure switches for air and water CS

Pressure switches for air and water CS Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the

More information

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay. Description: The High Efficiency Series air handlers are engineered to achieve or exceed today s demanding energy rating requirements. Specifically designed for horizontal mounting into a furred down ceiling.

More information

WatMan WATER RO SYSTEMS FOR DESALINATION

WatMan WATER RO SYSTEMS FOR DESALINATION WatMan WATER RO SYSTEMS FOR DESALINATION The WatMan reverse osmosis systems produce from 1 to 2000 m 3 per day of high quality water suitable for communities, marine environment, boiler feed and general

More information

G96 Series BASOTROL Dual Operator Valve

G96 Series BASOTROL Dual Operator Valve Installation Instructions 9. Issue Date February 22, 2013 G96 Series BASOTROL Dual Operator Valve Applications The G96 valves are combination, dual operator, automatic valves available with or without

More information

DECLARATION OF INCORPORATION

DECLARATION OF INCORPORATION AESSEAL (MCK) Ltd. Systems Division 139a Hillsborough Old Road Lisburn Northern Ireland BT27 5QE Tel +44 (0) 2892 669966 Fax +44 (0) 2892 669977 When selecting and installing suitable Barrier Fluid System

More information

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical

More information

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Installation Instructions Issue Date August 19, 2008 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Application The G196 valves are suitable for use with natural gas, Liquefied

More information

Electro-Pneumatic Converter YT-940 SERIES

Electro-Pneumatic Converter YT-940 SERIES Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product

More information

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.

Oxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions. Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists

More information

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18 The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability

More information

Two-port seat valves

Two-port seat valves 4 345 Two-port seat valves with flange, PN16 VVF45... Two-port seat valves with flange, PN16 Spheroidal cast iron GGG-40 DN50...150 mm k vs 19...300 m 3 /h Stroke 20 or 40 mm Can be equipped with actuators

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

3200 WHOLE HOUSE FAN INSTALLATION & OPERATION MANUAL

3200 WHOLE HOUSE FAN INSTALLATION & OPERATION MANUAL ORDER #: S/N: (Required for Warranty) 3200 WHOLE HOUSE FAN INSTALLATION & OPERATION MANUAL Thank you for purchasing this AirScape whole house fan. Your fan has been designed to provide your home with natural,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HIGH PRESSURE PUMP To minimize vibration, it is best to build brackets on the motor itself, similar to alternator brackets. Use cardboard to construct a pattern first before making

More information

PressVal Pressurisation Units. Packaged Pressurisation Units with expansion vessels for heating systems.

PressVal Pressurisation Units. Packaged Pressurisation Units with expansion vessels for heating systems. PressVal Packaged with expansion s for heating systems. lamco Basepak LEXILLER lamco Basepak LEXILLER POWER AULT MUTE/ RESET SYSTEM OK lamco ON / O lamco Basepak LEXILLER PressVal SM skid mounted units

More information

DS MZ, MZF, MJF THREE-PORT SEAT VALVES

DS MZ, MZF, MJF THREE-PORT SEAT VALVES DS 4.610 11/99, F, THREE-PORT SEAT VALVES Specification No. 626-3-XXX These seat valves are of 'globe' construction with a linear moving spindle and a modified parabolic characterised plug operating against

More information

Chlorinator. MODEL C-731 (Floor Mounted)

Chlorinator. MODEL C-731 (Floor Mounted) Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive

More information

RPS900W Redundant Power Supply. Installation Guide.

RPS900W Redundant Power Supply. Installation Guide. RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A

More information

Evolution. Radiant Panels. Radiant panel system LPHW up to 90 C Suspended ceiling grid or sofit mounting Vertical wall surface mounting

Evolution. Radiant Panels. Radiant panel system LPHW up to 90 C Suspended ceiling grid or sofit mounting Vertical wall surface mounting Evolution Radiant Panels Radiant panel system LPHW up to 90 C Suspended ceiling grid or sofit mounting Vertical wall surface mounting Contents IDENTIFICATION DESCRIPTION Page STYLE CG 3-7 STYLE CS, FC

More information

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3

TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 The following tasks parallel the Jr. Tech (JT-1, 2, 3) description and development plan and use the Refrigeration and Air conditioning

More information

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 170663_air_saving_products 17-02-2011 16:42 Pagina 1 Locator Locator-D-Lux Air-Saver G1 Air-Saver G2 AIR SAVING PRODUCTS 170663_air_saving_products 17-02-2011 16:42 Pagina 2 170663_air_saving_products

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

RA-N radiator valves with integrated presetting and self-sealing tailpiece

RA-N radiator valves with integrated presetting and self-sealing tailpiece Data sheet RA-N radiator valves with integrated presetting and self-sealing tailpiece EN 215 Application Straight version Angle version Horizontal angle version All RA-N valve bodies can be used together

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment

More information

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 257a. September 16, 2013 September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking

More information

TECHNICAL DATA. Trimpac 256a. October 31, 2013

TECHNICAL DATA. Trimpac 256a. October 31, 2013 October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve

More information

GEMINI 8-M Telescopes Project

GEMINI 8-M Telescopes Project GEMINI 8-M Telescopes Project SPE-S-G0048 Facility Thermal Management System Jim Oschmann Systems Engineering Group Robert Ford Telescope and Enclosure Group 28 June 1994 GEMINI PROJECT OFFICE 950 N. Cherry

More information

SECTION TESTING ADJUSTING AND BALANCING FOR HVAC

SECTION TESTING ADJUSTING AND BALANCING FOR HVAC SECTION 23 05 93 - TESTING ADJUSTING AND [Note to PSC: Existing System Coordination When connecting to an existing system, it is the PSC s Responsibility to examine existing documents, field verify existing

More information

Highest Quality. Gas Chlorination Systems

Highest Quality. Gas Chlorination Systems Highest Quality Gas Chlorination Systems Application: Gas chlorination systems are used for water disinfection and other purposes in a variety of applications. Compared to other disinfection methods, chlorine

More information

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils 4 440 Three-port valves with flange, PN6 VXF4... Three-port valves with flange, PN6 Can be used as mixing or diverting valves Grey cast iron GG-25 DN5...50 mm k vs.9...300 m 3 /h Stroke 20 or 40 mm Can

More information

MANAGEMENT PROCEDURE FOR LABORATORY VENTILATION

MANAGEMENT PROCEDURE FOR LABORATORY VENTILATION UNIVERSITY OF ALASKA FAIRBANKS SAFETY SYSTEM POLICY AND PROCEDURE DOCUMENT NUMBER: 508 ISSUE DATE: SEPTEMBER 1996 SUBJECT: Management Procedure for Laboratory Ventilation MANAGEMENT PROCEDURE FOR LABORATORY

More information

PRICED BID -PACKAGE II Page 1 of 19 Vendor Seal and Signature. Set 103. Set 23 pulse transmitter and Non return valve for 1.5" ethanol line.

PRICED BID -PACKAGE II Page 1 of 19 Vendor Seal and Signature. Set 103. Set 23 pulse transmitter and Non return valve for 1.5 ethanol line. 1 2 3 Supply of flowmeters 3" line: Supply of Positive displacement type flowmeters, Strainer with DPG, air eliminator, with pulse transmitter for 3" line Erection of Positive displacement type flowmeters,

More information

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel OM006 Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel The operating and maintenance instructions contained within this package are for standard mild steel buffer vessels

More information

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING

English. Introduction. Safety Instructions. All Products. Inspection and Maintenance Schedules. Parts Ordering. Specifications WARNING WARNING Contents All Products... Gb-1 Control Valves... Gb-2 Control Valve Actuators... Gb-3 Regulators... Gb-3 Relief Valves... Gb-4 Instruments, Switches, and Accessories... Gb-4 Products Covered by Battery

More information

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Air Technology Systems, Inc. Table of Contents Section - 1 Table

More information

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08 Parts Manual STRIKER 2840 Striker 2840 Parts List - PN 238155 - Printed in USA 03/18/08 Standard Parts Recommended General Wear Parts Ref No Part Description Qty Part No 1 Squeegee Hose Assembly

More information

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2

Simple Set. Pressure Independent Control Valves 2 Way 1/2-2 The Bray Simple Set is a threaded pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SS Series combines high rangeability control

More information

Inert Air (N2) Systems Manual

Inert Air (N2) Systems Manual INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range Models: DS 126 Single Pump / Single System DT 126 Twin Pump / Single System DS 160

More information

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction. Bulletin 335 Model DDX-LP Dry Pipe Valve System 8 (200mm) Bulletin 335 Features 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Differential latching clapper-type, lighweight, dependable construction. Low Air Pressurized

More information

Data Sheet Issue A

Data Sheet Issue A Features 1. Differential latching clappertype, lighweight, dependable construction. 2. Low Air Pressurized System, 8 psi -to- 26 psi (0,6 bar to- 1,8 bar) 3. Reset externally. Cover removal is not required.

More information

CALEFFI. Flow rate metering device. 683 series 01040/10 GB. Function

CALEFFI. Flow rate metering device. 683 series 01040/10 GB. Function low rate metering device 683 series CCRI 040/ GB ISO 900 M 64 ISO 900 No. 0003 unction he flow rate metering device is used to measure the flow rate within a circuit. When used for central heating purposes,

More information

Prestige Water Equipment Ltd.

Prestige Water Equipment Ltd. The Prestige range of water softeners complements the range of water pre-treatment products and services. Use of water softening minimises the problems caused by hard water scale such as reduced heat transfer

More information

Installation and commissioning instructions 255 series and 256 series

Installation and commissioning instructions 255 series and 256 series Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...

More information

Vertex VP Operation and Maintenance

Vertex VP Operation and Maintenance AIRBENCH LTD Vertex VP Operation and Maintenance This Edition: 2 October 2018 AirBench Ltd, 14 Grange Farm Road, Colchester CO2 8JW www.airbench.com +44 (0) 1206 791191 Copyright AirBench Ltd 2016 Page

More information

NOTE: Inserted Literature Supplement - YT Style "J" Chillers New Style Oil Filter/"O"-Ring

NOTE: Inserted Literature Supplement - YT Style J Chillers New Style Oil Filter/O-Ring MILLENNIUM TM CENTRIFUGAL LIQUID CHILLERS RENEWAL PARTS Supersedes: 160.48-RP5(LS2)(800) UNIT COMPONENTS MODEL YT STYLE J Form 160.48-RP6 (501) NOTE: Inserted Literature Supplement - YT Style "J" Chillers

More information

Automatic balancing valves ASV

Automatic balancing valves ASV Automatic balancing valves ASV ASV-P ASV-PV ASV-PV ASV-PV ASV-I ASV-M 15-40 15-40 50 65-100 15-50 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance in heating and

More information

Powers Controls D Day-Night Thermostats

Powers Controls D Day-Night Thermostats Powers Controls D Day-Night Thermostats Technical Instructions Document No. 155-073P25 TH 832-2 Description The D Day-Night or Two Temperature Thermostat is available as a room-type instrument. It is essentially

More information

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL

WATER MADE EASY MARINE ENERGY MUNICIPAL INDUSTRIAL Capital Controls Series 71V3000 The Series 71V3000 electrically-heated vaporizer automatically vaporizes and superheats liquid chlorine, sulfur dioxide or ammonia at a rate controlled by the gas feed system.

More information

JET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE

JET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE JET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE i Read the instructions 1. Installation mounting By purchaising the ELEGANCE device, you obtained a high-quality product that will help you to enjoy the

More information

TotalPac X Single interlock Preaction system Electric release

TotalPac X Single interlock Preaction system Electric release DESCRIPTION This TOTALPAC X integrated fire protection system by FireFlex Systems Inc. consists of a preaction system trim totally preassembled, pre-wired and factory tested. All electrical and mechanical

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

AUTOMATIC GAS MANIFOLDS

AUTOMATIC GAS MANIFOLDS AUTOMATIC GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

3200 whole house FAN INSTAllATION & OpERATION MANuAl

3200 whole house FAN INSTAllATION & OpERATION MANuAl OrDer #: s/n: (required for Warranty) 3200 whole house FAN INSTAllATION & OpERATION MANuAl Thank you for purchasing this Airscape whole house fan. Your fan has been designed to provide your home with natural,

More information

Remeha Quinta Cascade guide

Remeha Quinta Cascade guide Technical information Remeha Quinta Cascade guide Cascade guide Cascade systems 2 Remeha Quinta Cascade guide TABLE OF CONTENTS FOREWORD 4 1 GENERAL DESCRIPTION OF CASCADE SYSTEMS 4 1.1 Optimum number

More information

Rheem Spare Parts Manual Commercial gas model A Exterior 265L

Rheem Spare Parts Manual Commercial gas model A Exterior 265L Commercial gas model A631265 Exterior 265L 1 2 36 3 6 14 11 31 7 40 8 9 10 14 22 23 25 11 16 24 7 12 13 9 20 21 19 17 18 37 38 39 34 35 26 4 5 32 30 39 29 38 27 33 37 28 Commercial gas model A631265 Exterior

More information

System 100: 110 x 54mm Rectangular Ducting and Fittings 5 7. System 125: 150 x 70mm Rectangular Ducting and Fittings 8 9

System 100: 110 x 54mm Rectangular Ducting and Fittings 5 7. System 125: 150 x 70mm Rectangular Ducting and Fittings 8 9 British Manufacturing since 1986 Contents Page About Us 4 System 100: 110 x 54mm Rectangular Ducting and Fittings 5 7 System 125: 150 x 70mm Rectangular Ducting and Fittings 8 9 System 150: 180 x 95mm

More information

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01

WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function GB-WND 055 D01 WhirlWind Multifunctional gas control Fully integrated gas-air system with control and safety function Printed in Germany Edition 01 1 6 Technical Description Integrated gas-air system with high power

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

UNVENTED HOT WATER SYSTEMS HAVE BECOME EXTREMELY POPULAR FOR BUILDING APPLICATIONS. WITH ALL THE MANDATORY

UNVENTED HOT WATER SYSTEMS HAVE BECOME EXTREMELY POPULAR FOR BUILDING APPLICATIONS. WITH ALL THE MANDATORY Unvented Packages Contents UNVENTED HOT WATER SYSTEMS 1 SYSTEM SCHEMATICS 2 PACKAGED EQUIPMENT 3 UNVENTED PACKAGES 4 DESIGNING UNVENTED SYSTEMS 5-7 CONVERSION FACTORS 8 EXPANSION VESSEL SELECTION TABLES

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

SyncroFlo Municipal University and Hydraulic Institute, Pump Systems Optimization

SyncroFlo Municipal University and Hydraulic Institute, Pump Systems Optimization SyncroFlo Municipal University and Hydraulic Institute, Pump Systems Optimization COURSE SYLLABUS September 16 th 18 th, 2013 9/16/13 Day One Hydraulic Institute Workshop (8:30am) PUMP SYSTEMS OPTIMIZATION:

More information

2-step solenoid valve Type ICLX

2-step solenoid valve Type ICLX Data sheet 2-step solenoid valve ICLX 32-150 ICLX 2-step solenoid valves belong to the ICV family. ICLX are used in suction lines for the opening against high differential pressure, e.g. after hot gas

More information