MV-105 MEDIUM VOLTAGE CABLE. 5kV, 8kV, 15kV, 25kV & 35kV
|
|
- Reginald Elliott
- 5 years ago
- Views:
Transcription
1 MV-05 MEDIUM VOLTAGE CABLE 5kV, 8kV, 5kV, 5kV & 5kV
2 MV-05 MEDIUM VOLTAGE POWER CABLE 5kV % INSULATION LEVEL 8kV 00% INSULATION LEVEL Conductor conforming to ASTM B and Class B Compact stranded in accordance with ASTM B9. Grounding Conductor conforming to ASTM B and Class B stranded in accordance with ASTM B8. Shield Nonmetallic insulation shield meets or exceeds electrical and physical requirements of UL 07. Conductor Shield conductor shield meets or exceeds electrical and physical requirements of UL 07. EPR meets or exceeds electrical and physical requirements of UL 07. Metallic Shield Bare copper tape shield helically wrapped to provide 00% coverage. Binder Tape Synthetic material assembles the core in an essentially round configuration. Jacket Overall polyvinyl chloride jacket per UL 07, C temperature rating; low acid gas emission; limited flame spread and excellent corrosion resistance. APPLICATION Nexans Amer medium voltage power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations. Type MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 50.(A)(5), or messenger supported in industrial establishments and electric utilities. FEATURES UL listed as Type MV-05 Flame retardant: UL 85 and IEEE 8 vertical tray fire tests at 70,000 BTU/hr, IEEE 0 and CSA FT Excellent mechanical and physical properties Sunlight resistant jacket Suitable for direct burial, use in cable tray and embedment in concrete BEND RADIUS Fixed position: 7 x cable overall diameter During pulling: x cable overall diameter Ratings & Approvals 05 C Temperature Rating Meets UL 07 requirements for medium voltage power cables meets electrical and physical requirements of ICEA S-9-9/NEMA WC 7 and UL 07 Meets AEIC CS 8 Specification for Extruded Dielectric Shielded Power s Rated 5 Through kv downstream@nexansamercable.com
3 5kV 00% INSULATION /C /0 / kV % INSULATION 8kV 00% INSULATION /C C C ductive /0 / C C ductive kV % INSULATION 8kV 00% INSULATION /C /0 /0 50 Ground C C ductive Notes: ) in air are based on NEC 07 Table 0.0(C)(7), for insulated three conductor copper cable isolated in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) in cable tray are based on NEC 07 Table 0.0(C)(75), for insulated three conductor copper cable in isolated conduit in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) for direct burial are based on NEC 07 Table 0.0(C)(8), for insulated three conductor copper cable, directly buried, maximum conductor temperature of 05 C, ambient earth temperature of 0 C, 00 percent load factor, earth thermal resistivity of C cm / W Fax:
4 MV-05 MEDIUM VOLTAGE POWER CABLE RATED 5kV 5kV Conductor conforming to ASTM B and Class B Compact stranded in accordance with ASTM B9. Grounding Conductors conforming to ASTM B and Class B stranded in accordance with ASTM B8. Shield Nonmetallic insulation shield meets or exceeds electrical and physical requirements of UL 07. Conductor Shield conductor shield meets or exceeds electrical and physical requirements of UL 07. EPR meets or exceeds electrical and physical requirements of UL 07. Metallic Shield Bare copper tape shield helically wrapped to provide 00% coverage. Binder Tape Synthetic material assembles the core in an essentially round configuration. Jacket Overall polyvinyl chloride jacket per UL 07, C temperature rating; low acid gas emission; limited flame spread and excellent corrosion resistance. APPLICATION Nexans Amer medium voltage power cables are recommended for use as feeder circuits, in electric utility generating stations, for distribution circuits, and for feeders or branch circuits in industrial and commercial installations. Type MV cables may be installed in wet or dry locations, indoors or outdoors (exposed to sunlight), in any raceway or underground duct, directly buried if installed in a system with a grounding conductor in close proximity that conforms with NEC Section 50.(A)(5), or messenger supported in industrial establishments and electric utilities. FEATURES UL listed as Type MV-05 Flame retardant: UL 85 and IEEE 8 vertical tray fire tests at 70,000 BTU/hr, IEEE 0 and CSA FT Excellent mechanical and physical properties Sunlight resistant jacket Suitable for direct burial, use in cable tray and embedment in concrete Phase identification: Color coded (black, red, blue) polyester ribbon laid longitudinally under the copper shield tape Ratings & Approvals 05 C Temperature Rating Meets UL 07 requirements for medium voltage power cables meets electrical and physical requirements of ICEA S-9-9/NEMA WC 7 and UL 07 Meets AEIC CS 8 Specification for Extruded Dielectric Shielded Power s Rated 5 Through kv BEND RADIUS Fixed position: 7 x cable overall diameter During pulling: x cable overall diameter downstream@nexansamercable.com
5 5kV % INSULATION /C /0 / C C ductive kV % INSULATION LEVEL /C /0 /0 50 Ground C C ductive kV % INSULATION 5kV 00% INSULATION /C /0 / C C ductive Notes: ) in air are based on NEC 07 Table 0.0(C)(7), for insulated three conductor copper cable isolated in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) in cable tray are based on NEC 07 Table 0.0(C)(75), for insulated three conductor copper cable in isolated conduit in air, maximum conductor temperature of 05 C, ambient air temperature of 0 C. ) for direct burial are based on NEC 07 Table 0.0(C)(8), for insulated three conductor copper cable, directly buried, maximum conductor temperature of 05 C, ambient earth temperature of 0 C, 00 percent load factor, earth thermal resistivity of C cm / W Fax:
6 DOWNSTREAM OIL & GAS CABLES Nexans 0 West Little York Road - Building - Suite Fax: downstream@nexans.com 08, Amer corporated _8 CLICK HERE TO FOLLOW US!
Type MMV Medium Power Cable
7-05 Type MMV Medium Power Cable Single Conductor: 5kV 5kV, 00% & % Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & % Insulation Levels. Rated 90 C Conductors Soft annealed flexible stranded
More informationCY LSOH Screened Halogen Free Control Cables with improved fire performance
LSZH Screened Flexible Control Cable Application Range For installation where fire, smoke emission and toxic fumes Create a potential threat to life and equipment. Can be used as interconnecting cable
More informationElectronic Instrumentation
Shielded multipair and multitriad - 00V - 105 C - PLTC - UL 1 Applications Electronic instrumentation, analog and digital signal circuits (-ma). Intrinsically safe circuits. Gas and/or fluid leak detection
More informationTECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS
TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS CONTENTS: 1.0 General Information 2.0 Preparation and Splicing of PinPoint Wire 3.0 PinPoint Direct Bury Splice Kit Specifications
More informationBaseline Two-Wire Technology
Baseline Two-Wire Technology Baseline s bicoders work with Baseline s biline two-wire technology to create the only true bi-direc onal two-wire devices in the industry. Baseline s bicoders not only receive
More informationNinth Edition, September Cable Installation Manual for Power and Control Cables. Foreword
Foreword Welcome to the ninth edition of General Cable s Cable Installation Manual for Power and Control Cables. This manual provides installation information for power and control cables for industrial.
More informationSOUTHWIRE company SUbSTaTIOn cable InSTallaTIOn guide
SOUTHWIRE company Substation cable installation guide Southwire Company One Southwire Drive Carrollton, Georgia 30119 2013 Southwire Company. All rights reserved. Printed in the United States of America.
More informationHV Spiker Kit - CSTE. 30 th April 2014
HV Spiker Kit - CSTE 30 th April 2014 Safety Working With Cables As a cable jointer, safety is paramount when working daily with live electricity. When working with cables it is essential to know whether
More informationAmphenol. PowerLink Solar Cables. Amphenol 97 Series Connectors are UL recognized and CSA recognized.
Amphenol PowerLink Solar Cables www.amphenol-industrial.com Amphenol 97 Series Connectors are UL recognized and CSA recognized. PowerLink Solar Cables Amphenol s single conductor PowerLink Solar Cables
More informationResidential Swimming pools
City of Republic Community Development Department Residential Swimming pools REVISION DATE: JANUARY 2017 Swimming Pool Safety Definitions: Barrier Requirements: A) Application All swimming pools over 24
More informationDefinitions for swimming pools, fountains, and similar installations in article 680
Definitions for swimming pools, fountains, and similar installations in article 680 Dry-Niche Luminaire. A luminaire intended for installation in the floor or wall of a pool, spa, or fountain in a niche
More informationPUR cable. PUR cable. The harmonised version H05BQ-F/H07BQ-F can be used at building construction areas and where HAR-approval is required in Europe.
Polyurethan (PUR) cables are suitable as control cables, for fl exible use where high mechanical stress occurs. The PUR outer jacket has very good resistance against mineral oils and different chemical
More informationCheck with local zoning official for property line distance requirements.
RESIDENTIAL POOL PLAN SUBMITTAL GUIDELINES The following guidelines are intended to assist municipal residents with the permit acquisition process with regard to pools, spas and hot tubs for single family
More informationGENERAL NOTES FOR SWIMMING POOLS AND SPAS
GENERAL NOTES FOR SWIMMING POOLS AND SPAS 1. Buried Poly Ethylene (PE) pipe gas lines shall be 18 below finish grade or in an approved recessed channel with 14 gauge insulated tracer wire; Galvanized malleable
More informationSelection of Electrical PPE Tables
Selection of Electrical PPE Tables Instructions Table 1 - Starting with Table 1, select the task you plan to do (right-hand column) and the condition of the equipment you will be working on, (center column).
More informationPart 3: Safety Rules for the Installation and Maintenance of Underground Electric Supply and Communication Lines
Part 3: Safety Rules for the Installation and Maintenance of Underground Electric Supply and Communication Lines Charles Bleakley Chair, Subcommittee 7 PART 3 UNDERGROUND LINES 2 313. Inspection and tests
More informationCABLE PULLING GUIDELINES
The following data is intended as a general guide to aid individuals with the installation of cables inside ducts, raceways or conduit. These recommendations are based upon a study sponsored by the ICEA
More informationThese Electricity Safety Rules and associated National Safety Instructions are written to safeguard personnel working for or on behalf of National
These Electricity Safety Rules and associated National Safety Instructions are written to safeguard personnel working for or on behalf of National Grid, on or near to its electricity apparatus. National
More informationComtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant
Comtran Cable Commercial Premise & Specialty Datacom Products Cat 5e - Cat 6A LSZH & Industrial Ethernet Indoor/Outdoor & Outside Plant Category 6 : UL Type CMP : UL Type CMR Commercial Premise =====================================================================
More informationYSLY-JZ YSLY-OZ. Low voltage - Energy, cabling, signalling and control
Low voltage - Energy, cabling, signalling and control YSLY-JZ YSLY-OZ Construction: VDE Reg. n 7509 according to VDE 0281 Teil 13 according to DIN EN 50525-2-51 Flame propagation: DIN EN 60332-1-2 Low
More informationINSTALLATION INFORMATION
This publication contains a collection of general information related to the installation of power cables. The design of power cable installations and installation of power cables should be done by competent
More informationCriteria. Table of Contents
Criteria Title: UNDERGROUND TRANSMISSION LINE AMPACITY RATINGS Department: Document No: Issue Date: Previous Date: Asset Management CR-0062 v06 12-28-2012 05-24-2010 Table of Contents 1.0 Scope... 2 2.0
More information$ Plan Review Fee when Permit Application is submitted HOT TUBS AND SPAS BUILDING PERMIT APPLICATION. COST: $80.
Community Development 1050 W Romeo Rd, Romeoville, IL 60446-1530 (815) 886-7200 Fax #: (815) 886-2724 Email: buildinginspections@romeoville.org HOT TUBS AND SPAS BUILDING PERMIT APPLICATION Application
More informationNottingham Township 909 Sugar Run Road Eighty Four PA (724) Fax (724)
Nottingham Township 909 Sugar Run Road Eighty Four PA 15330 (724) 348-5622 Fax (724) 348-8822 Swimming Pool Application Requirements SWIMMING POOL Any structure intended for swimming or recreational bathing
More informationCONTINUING EDUCATION FOR WISCONSIN ELECTRICIANS NEC Article Hours
3 CONTINUING EDUCATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 680 3 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com
More informationPRODUCT INFORMATION ÖLFLEX ROBUST 215 C
GmbH PRODUCT INFORMATION Proven all-weather control cables resistant to a wide range of chemical media Outstanding weather, ozone and UV resistance together with the wide temperature range enable versatile
More informationSMARTen STP Patch Cords Features
Features Patch Cords are used in the work area and cross-connect generic cabling applications Comprise a length of eight-wire flexible patch cable, terminated with two eight-position RJ-45 plugs at each
More informationPART I. GENERAL REQUIREMENTS FOR PERMANENTLY INSTALLED POOLS, STORABLE POOLS, OUTDOOR SPAS, OUTDOOR HOT TUBS, OR FOUNTAINS
The overriding concern of Article 680 is to keep people and electricity separated. Some ways in which Article 680 accomplishes this include: References to other articles. Equipment Requirements. Any equipment
More informationSemoflex Roboschlepp The PUR cable for cable chains
Semoflex Roboschlepp The PUR cable for cable chains Description Application For use in cable chains and continual moving machines and robots. Because of the polyurethane outer sheath the cable outer diameter
More informationGENERAL APPLICATION NOTES
GENERAL APPLICATION NOTES There are common considerations when using our connectors. Additional considerations may apply based on the particular connector being used, the application, and conditions in
More informationMISSOURI UNIVERSITY OF SCIENCE & TECHNOLOGY Procedure: 3.6
Procedure This electrical safety procedure structures safety procedures to meet the requirements of the NFPA-70E Standard. The program is designed for qualified employees who occasionally must perform
More informationElectrical Tapes Selection Guide. 3Innovation
Electrical Tapes Selection Guide Innovation M Electrical Tape Chart PRODUCT NAME PRODUCT TAPE SIZES TEMPERATURE TYPICAL DESCRIPTION THICKNESS AVAILABLE RATING APPLICATIONS Vinyl Electrical Tapes Scotch
More informationSWIMMING POOLS CHAPTER 41
CHAPTER 41 SWIMMING POOLS SECTION E4101 GENERAL E4101.1 Scope. The provisions of this chapter shall apply to the construction and installation of electric wiring and equipment associated with all swimming
More informationAPPENDIX A. F107 & 380 Lines OYSTER RIVER DURHAM, NH
APPENDIX A F107 & 380 Lines OYSTER RIVER DURHAM, NH 1. The design and proposed construction of this crossing is shown on the attached PSNH Transmission Business Drawing entitled DOUBLE CKT F107 & 380 BETWEEN
More informationMECHANICAL ASPECTS OF SUBMARINE CABLE ARMOUR
MECHANICAL ASPECTS OF SUBMARINE CABLE ARMOUR Ernesto Zaccone ARMORING OF SUBMARINE CABLES Submarine cables must be robust Mechanical aspects are at least as important as the electrical o nes Must withstand
More informationCanadian Electrical Code, Part I Full Impact Assessment
Copyright CSA Group 2015 Canadian Electrical Code, Part I Full Impact Assessment Subject 3827 Recalculated underground ampacity tables CONTENTS 1 INTRODUCTION TO THE FULL IMPACT ASSESSMENT... 3 2 PURPOSE
More informationHalogen free cable. Halogen free cable
SABIX Flame retardent Non Corrosive, FRNC, is an halogen free material based on Polyolefi n that fulfi lls the international norms (IEC) when it comes to fl ame propagation. These cables in different versions
More informationCHAPTER 42 SWIMMING POOLS
CHAPTER 42 SWIMMING POOLS SECTION E4201 GENERAL E4201.1 Scope. The provisions of this chapter shall apply to the construction and installation of electric wiring and equipment associated with all swimming
More informationC-Line Electrical Connectors
C-Line Electrical Connectors Product Catalog (417) 532-7121 PO Box 908 722 Durham Rd Lebanon, MO 65536 Manufactured by: PO Box 908 722 Durham Rd Lebanon, MO 65536 Company Information C-Line Electrical
More informationBulletin Swimming pool, hot tub and spa installations Rules , , , , , and
Bulletin 68-7-11 Swimming pool, hot tub and spa installations Rules 68-000, 68-056, 68-058, 68-064, 68-068, 68-302 and 68-404 Scope (1) Swimming pools - general (2) Grounding & bonding (a) Bonding for
More informationSocket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11
Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double
More informationEVALUATION SUBJECT: SPUNSTRAND STANDARD AND INSULATED UNDERSLAB DUCTS
ICC-ES Report ESR-1681 Reissued 12/2017 This report is subject to renewal 12/2018 EVALUATION SUBJECT: SPUNSTRAND STANDARD AND INSULATED UNDERSLAB DUCTS DIVISION: 23 00 00 HEATING, VENTILATING AND AIR CONDITIONING
More informationInformation Sheet. About this information sheet. Floor and wall loadings. Attachment of process module to floor. PlasmaPro Estrelas100
Information Sheet PlasmaPro Estrelas100 About this information sheet This data sheet provides basic information about the installation of a PlasmaPro Estrelas100 tool. Some of the information in this sheet
More informationPre-Installation Manual. A-2 CPO Pinsetters. with Brunswick Bowling Equipment. March 2006 / B
Pre-Installation Manual A-2 CPO Pinsetters with Brunswick Bowling Equipment March 2006 / B-0306-14 A-2 CPO Pinsetters With Brunswick Bowling Equipment Pre-Installation Manual March 2006 by the Brunswick
More informationSwimming Pool Requirements
Swimming Pool Requirements 8040 S. 6th Street Oak Creek, WI 53154 (414) 766-7000 www.oakcreekwi.org Revised: August 8. 2017 PERMITS A permit from the Inspection Department is required prior to putting
More informationFlorida Building Code 6 th Edition (2017) Residential. Broward County Edition Loose-leaf Supplement
Board of Rules and Appeals FBC 6 th Edition (2017)- Residential - Supplement No. 1 January 1, 2018 Florida Building Code 6 th Edition (2017) Residential File removed pages for reference. Broward County
More informationSecurity and confidence at height.
A Security and confidence at height. Vertical Systems DISTRIBUTED BY M DBI-SALA Vertical Systems are designed to complement your ability to work while meeting all applicable OSHA and ANSI standards. Vertical
More informationProtected Microducts, Overview and Current Trends
Draka Comteq Netherlands / Comparison of Microduct Types for optical cables installation Protected Microducts, Overview and Current Trends W. Griffioen 1, W. Greven 2 1 Draka Comteq Cable Solutions, Amsterdam,
More informationPRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
More informationPredicting Medium-Voltage Underground-Distribution Cable Failures John P. Ainscough P. E., Member IEEE Ian W. Forrest P. E.
Predicting Medium-Voltage Underground-Distribution Cable Failures Nov. 11, 2009, Scottsdale, AZ Introduction The Birth of Suburbia - Starting in the 1950 s White House Conference on Natural Beauty Discussion
More informationC&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.
C&G 2395 Exam Paper April 2013 Section A - All questions carry equal marks. Answer all three questions. Show all calculations. Q.1 The electrical installation in a small food retail outlet is scheduled
More informationOutside Plant Single Armor Double Jacket
Berk-Tek s Outside Plant Loose Tube ber optic cables are designed for installation in harsh enviroments such as direct burial, aerial lashing, conduit and pathways that are subjected to wide temperature
More informationSADACHAIN CY PUR 1000 V
SADACHAIN CY PUR 1000 V 80 C UR/CSA SCHERMATO/SHIELDED HIGH EFFICIENCY CARATTERISTICHE TECNICHE TECHNICAL FEATURES CONDUTTORE CONDUCTOR Rame flessibile Cl. 6 secondo CEI 20-29 DIN-VDE 0295 e IEC 60228
More informationMedium voltage standard-duty, heavyduty, and extreme-duty single-phase, unfused capacitor units and accessories
Power Capacitors Catalog Data CA230003EN Supersedes January 2017 COOPER POWER SERIES Medium voltage standard-duty, heavyduty, and extreme-duty single-phase, unfused capacitor units and accessories General
More informationSWIMMING POOL REQUIREMENTS
PERMITS A permit from the Inspection Department is required prior to putting up a permanent pool. A permit is required for permanent pools, such as the following: SWIMMING POOL REQUIREMENTS The pool is
More informationCity of DuBois PERMIT APPLICATION P. O. Box 408, 16 West Scribner Ave - DuBois, PA Phone: Fax:
City of DuBois PERMIT APPLICATION P. O. Box 408, 16 West Scribner Ave - DuBois, PA. 15801 Phone: 814-371-2000 Fax: 814-375-2307 Permit No. LOCATION OF PROPOSED WORK OR IMPROVEMENT Municipality: Tax Parcel
More informationSwimming Pool Permits are About Health and Safety
Swimming Pool Permits are About Health and Safety Swimming Pool Booklet Published 2004 Revised 04/06/16 Permitting Department 80 W. Baltimore Street Hagerstown, Md. 21740 240-313-2460 (F) 240-313-2461
More informationIEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)
IEC 62271-200 April 2004 Authorized Sole Agent : PT. Wisma Niagatama Perkasa Phone : (031) 5041242 Fax. : (031) 5044580 IEC 62271-200 Introduction Scope This standard specifies requirements for factory-assembled
More informationPro-Tekt European Cable System. Technical Catalog
European Cable System Technical Catalog High-Performance Cables for Demanding Applications Every cable application is important, and durable, long-lasting equipment requires rugged reliability. Downtime
More informationPro-Flex,LLC. Flexible Gas Piping Systems. & Flak Jacket TM CSST. Installation/Training Guide. Pro-Flex,LLC
Pro-Flex,LLC Flexible Gas Piping Systems Pro-Flex & Flak Jacket TM CSST Installation/Training Guide Pro-Flex,LLC 501 South State Road 341 Hillsboro, IN 47949 Patented System: #5,845,946, #5,857,716, &
More informationSPECIFICATION SHEET. OMEGAFLEX, Ltd. TracPipe Flexible Gas Piping Specification Sheet Specification date. ProjectName
OMEGAFLEX, Ltd. TracPipe Flexible Gas Piping Specification Sheet Specification date ProjectName Model Number(s) - FGP-SS4-50 FGP-SS4-40 FGP-SS4-32 FGP-SS4-28 FGP-SS4-22 FGP-SS4-15 FGP-SS4-12 Note: This
More informationIndustry Guidelines POLYETHYLENE (PE) PIPES AND FITTINGS FOR COMPRESSED AIR ISSUE 6.8
Industry Guidelines POLYETHYLENE (PE) PIPES AND FITTINGS FOR COMPRESSED AIR ISSUE 6.8 Ref: POP002 19 APR 2009 Disclaimer In formulating this guideline PIPA has relied upon the advice of its members and,
More informationCity of Crystal Lake Community Development Department
City of Crystal Lake Community Development Department 100 W. Woodstock Street Crystal Lake, IL 60014 www.crystallake.org Phone (815) 356-3605 Fax (815) 479-1647 building@crystallake.org ABOVE GROUND SWIMMING
More informationOperating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
More informationC&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.
C&G 2395 Exam Paper June 2013 Section A-All questions carry equal marks. Answer all three questions. Show all calculations. 1. The electrical installation in an industrial unit is scheduled for a periodic
More informationSWIMMING POOL & SPA DOCUMENT SUBMITTAL LIST
SWIMMING POOL & SPA DOCUMENT SUBMITTAL LIST Completed Application for Construction or Use (Permit application). Application must include authorized signature from the property owner if it is not owner
More information2012 International Residential Code with the 2016 CT Amendment PRIVATE OUTDOOR SWIMMING POOL INFORMATION PACKAGE
2012 International Residential Code with the 2016 CT Amendment PRIVATE OUTDOOR SWIMMING POOL INFORMATION PACKAGE WHAT INFORMATION IS NEEDED IN ORDER TO OBTAIN A POOL PERMIT The information in this handout
More informationPRODUCTS CATALOG
2017-2018 PRODUCTS CATALOG THE BROADEST LINE OF QUALITY ELECTRICAL FITTINGS & TUBULAR PRODUCTS PLUS THE BEST PERFORMANCE GUARANTEE IN THE INDUSTRY ABOUT US Electroline is committed to manufacturing quality
More informationAMITY TWP POOL REQUIREMENTS
AMITY TWP POOL REQUIREMENTS Construction In-ground, Above-ground and Storable pools and Spas shall be designed and constructed in conformance with International Swimming Pool & Spa Code (ISPSC) Location
More informationOxford Instruments Plasma Technology. PlasmaPro NGP80. Installation Data Sheet. Original Instructions.
Oxford Instruments Plasma Technology www.oxford-instruments.com About this data sheet This data sheet provides basic information about the installation of a tool. Floor and wall loadings Table 1 lists
More informationOperating Instructions
Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2
More informationPRIVATE SWIMMING POOL AND SPA/HOT TUB INFORMATION PACKAGE
2009 International Residential Code portion of the 2005 State Building Code PRIVATE SWIMMING POOL AND SPA/HOT TUB INFORMATION PACKAGE The information within this packet is based on the 2009 International
More informationKMU SUBSTATION WORKSHOP
Rick Aguilar, Director of Job Training & Safety KMU SUBSTATION WORKSHOP JUNE 29-30, 2016 OTTAWA, KS Hazards & Safety Rules Qualified Personnel & Task-Based Hazard Mitigation Worksite Applications & Considerations
More informationFIRE PREVENTION METHOD FOR 275KV OIL-FILLED CABLE IN TEPCO
FIRE PREVENTION METHOD FOR 275KV OIL-FILLED CABLE IN TEPCO Atsushi Toya, Tokyo Electric Power Company, (Japan), toya.atsushi@tepco.co.jp Shinsuke Nasukawa, Tokyo Electric Power Company, (Japan), nasukawa.shinsuke@tepco.co.jp
More informationDT400/436 Tee Connector Installation Instructions
Connectors Lorem ipsum and dolor Splices sit Amat Effective September 2014 Supersedes IS550-30-1 March 2011 MN650001EN DT400/436 Tee Connector Installation Instructions DISCLAIMER OF WARRANTIES AND LIMITATION
More informationSingle-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA
62-10 Single-Phase Pad-Mounted Distribution Catolog Transformers Section Howard Industries, Inc. Certifi ed to ISO 9001:2015 62-10 Single-Phase Pad-Mounted Distribution Transformers 5-500 KVA 10002179
More informationEvaluation of Ground Ring vs. Equipotential Mat at a Swimming Pool in Buford, Georgia
Evaluation of Ground Ring vs. Equipotential Mat at a Swimming Pool in Buford, Georgia NEETRAC Project -132 August, 2 A Research Center of the Georgia Institute of Technology Requested by: Reuben Clark
More informationSuccessful traffic operations require precise, real-time information.
Successful traffic operations require precise, real-time information. Every year, more and more vehicles crowd the world s roadways aggravating congestion, increasing travel times and jeopardizing safety.
More informationAPPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL
APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL ROV & AUV PRODUCTS GRE (Glass Reinforced Epoxy) CS-MS 55 & 66 SERIES MINI-CON HUMMER GLOBE-CON ALL-WET
More informationGFCIs and Swimming Pools A Natural Fit
GFCIs and Swimming Pools A Natural Fit Swimming Pool Triangle Most of us have seen or read something about the figure commonly known as the fire triangle (oxygen, heat, and fuel), which is a working model
More informationFiber Cable Puller with Tuf-Lugger lite
7 OPERATING INSTRUCTION MANUAL Fiber Cable Puller with Tuf-Lugger lite Copyright 2015 DCD Design & Manufacturing Ltd. Revision 1.0 IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING The Fiber
More informationExperiences and Challenges of Combined HV & EHV Qualifications to IEC, AEIC and IEEE 48 & 404
Experiences and Challenges of Combined HV & EHV Qualifications to IEC, AEIC and 48 & 404 Caryn M. Riley, Josh Perkel, Raymond C. Hill, and R. Nigel Hampton NEETRAC, Atlanta, USA, caryn.riley@neetrac.gatech.edu,
More informationDatasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code)
Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code) ENGLISH Duplex (2-channel) standard connector that accepts solid, round plug pins Bodies supplied
More informationRESIDENTIAL SWIMMING POOL REQUIREMENTS
CITY OF GRANDVIEW / BUILDING SERVICES 1200 MAIN STREET, GRANDVIEW, MO 64030 PHONE: (816) 316-4817 FAX: (816) 316-4809 WWW.GRANDVIEW.ORG RESIDENTIAL SWIMMING POOL REQUIREMENTS Community Development Department
More informationPERMANENT POOLS. Location
Community Development Department 211 Walnut Street - PO Box 426 Neenah, WI 54957-0426 Phone: (920) 886-6130 Fax: (920) 886-6129 Web site: www.ci.neenah.wi.us PERMANENT POOLS A pool is any man-made structure,
More informationCMC Series Moulded Case Circuit Breaker Cielo Electric
Model name CMC: Series 225: mpere frame size Line side terminal In: Rated current Ue: Rated operational voltage Icu: Rated ultimate short-circuit breaking capacity Ta: mbient temperature In: 225 Icu: 55k@415V
More informationVERSION 1.2 R-TRACK USER GUIDE. ZiPPERTUBiNG CO. THE. (480)
VERSION 1.2 USER GUIDE THE ZiPPERTUBiNG CO. www.zippertubing.com (480) 285-3990 R Table of Contents pg.2 TABLE OF CONTENTS Introduction... 3 Track Closure vs Bend Location... 4 Installation... 5 Sealing
More informationVacuum Excavation in the vicinity of the Wellington Electricity Network
Vacuum Excavation in the vicinity of the Network. Document no: ENG-116 Document Rev: 1 Issue Status: Final Issue Date: 14/05/2015 Page 1 of 9 Contents 1. PURPOSE... 3 2. POLICY... 3 3. SCOPE... 3 4. REFERENCES...
More informationFiber Optic Splice Closures
Fiber Optic Splice Closures . Products Descriptions of Optical Closure and Splice Tray FOCSS FOCS FOCM Splice Tray-2C Splice Tray-24C Dimensions (mm): 225(l) 08(w) 2(h) Dimensions (mm): 68(l) 9(w) 9(h)
More informationkēlo LED Light Installation Instructions
kēlo LED Light 4005496 ETL LISTED Conforms to UL STD 676; Certified to CSA STD C22.2 #89 Installation Instructions Read all instructions before attempting to perform installation work Installation information
More informationUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL
UL 2556 Wire and Cable Test Methods MARCH 22, 2013 UL 2556 tr1 UL Standard for Safety for Wire and Cable Test Methods, UL 2556 Third Edition, Dated March 22, 2013 Summary of Topics This New Third Edition
More informationBest Practice Guide, Servomex 2700
For full installations details refer to the. Best Practice Guide, Servomex 2700 Mounting: General Guidelines: Servomex 2700 Control Units and air supplies (utilities units) should, ideally, be mounted
More informationFigure Source:
In the Fall of 2018, EPRI opened a test facility to the public so that they could witness testing at the EPRI swimming pool assessment infrastructure within EPRI s laboratory in Lenox, Massachusetts. Those
More informationMicafil RIP bushings High-voltage Resin Impregnated Paper bushings. Power and productivity for a better world TM ABB
Micafil RIP bushings High-voltage Resin Impregnated Paper bushings Power and productivity for a better world TM ABB Leading in Bushings Technology: ABB Micafil ABB Micafil has been closely associated with
More informationSIROCCO. Robust high-pressure diecast aluminium housing. Computer aided design reflector. Graduated scale for accurate aiming.
SIROCCO is a family of floodlight, surface washer and area lighting. Three (3) types of light distribution, asymmetric, bi-symmetric, and road optic. Available in 2 sizes with a range of mounting accessories
More informationApplications and Considerations Section 11
11 Applications and Considerations Section 11 www.hubbellpowersystems.com E-mail: hpsliterature@hps.hubbell.com Phone: 573-682-5521 Fax: 573-682-8714 210 North Allen Centralia, MO 65240, USA Copyright
More informationFlex Cable Portfolio
Flex Cable Portfolio More Flexibility in Cable Choice and Performance Alpha Wire s extensive line of flex cable is designed to deliver exceptional performance and reliability in the most strenuous of environments.
More informationAcknowledgement must be given for the assistance provided by Barry Hutchens, Kenji Iwanaga, and AJ Murguia in preparing this booklet.
1.Introduction. This booklet was prepared in order to assemble the major regulations affecting swimming poolsor spas in a single package. It is primarily oriented toward installations at private residences.
More informationMicafil RIP bushings High-voltage Resin-Impregnated Paper bushings. Power and productivity for a better world TM ABB
Micafil RIP bushings High-voltage Resin-Impregnated Paper bushings Power and productivity for a better world TM ABB Leading in Bushings Technology ABB Switzerland Ltd has been closely associated with innovation
More informationPOWR-BLOKS Distribution/Splicer Blocks and Covers
SPECIFICATIONS Voltage : 600V erage: Based on NEC Table 310-16, using 75 C copper wire Material: Phenolic rated at 150 C and Thermoplastic rated at 125 C (LD1400 and LS1300 series only) : Standard: Highly
More information