CY LSOH Screened Halogen Free Control Cables with improved fire performance

Size: px
Start display at page:

Download "CY LSOH Screened Halogen Free Control Cables with improved fire performance"

Transcription

1 LSZH Screened Flexible Control Cable Application Range For installation where fire, smoke emission and toxic fumes Create a potential threat to life and equipment. Can be used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors. Typical applications include: Plant engineering, industrial machinery Public buildings Airports Railway stations Heavy duty control equipment Used as interconnecting cable for measuring, controlling or regulation in control systems Also used in production lines and conveyors Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Particularly where human and animal life, as well as valuable property are exposed to high risk of fire hazards Technical Data Core Identification: VDE0293 BS EN Black with White numbers (3 cores and above includes Green/Yellow) Conductor Stranding: IEC60228 Class 5 Flexible stranded copper conductors Insulation Resistance Min. 10MOhm x km Minimum Bending Radius Flexing: 15 x cable ø Fixed: 4 x cable ø Nominal Voltage 300/500V Test Voltage 4000V Temperature Range Occasional flexing: -15ºC to + 70ºC Fixed Installation: -40ºC to + 70ºC Product Features Halogen-free IEC (Amount of Halogen Acid Gas) (Corrosiveness of combustion gases according to IEC (degree of acidity) Flame Retardant IEC (Flame spread on a single cable) Design Fine Wire Strands Class 5 and VDE 0295 Halogen Free core insulation Halogen Free outer sheath (RAL 7001)

2 Part number CY LSOH Number of cores and mm² per conductor Outer diameter (mm) Copper index (kg/km) Weight (kg/km) X 0,5 5, G 0,5 6, X 0,5 6, G 0,5 6, X 0,5 6, G 0,5 7, X 0,5 7, G 0,5 7, X 0,5 7, G 0,5 10, G 0,5 11, G 0,5 13, X 0,75 6, G 0,75 6, X 0,75 6, G 0,75 7, X 0,75 7, G 0,75 7, X 0,75 7, G 0,75 8, X 0,75 8, G 0,75 11, X 0,75 11, G 0, G 0,75 15, X 1,0 6, G 1,0 6, X 1,0 6, G 1,0 7, X 1,0 7, G 1,0 8,

3 Part number Number of cores and mm² per Outer diameter (mm) Copper index (kg/km) Weight (kg/km) conductor X 1,0 8, G 1,0 8, X 1,0 8, G 1,0 11, X 1,0 11, G 1,0 14, G 1,0 16, X 1,0 16, X 1,5 7, G 1,5 7, X 1,5 7, G 1,5 8, X 1,5 8, G 1,5 9, X 1,5 9, G 1, X 1, G 1,5 13, G 1,5 15, G 1,5 18, X 2,5 8, G 2,5 9, G 2, G 2,5 11, G 2, G 2,5 16, G 4 10, G 4 11, G 4 13, G 4 14,

4 Part number Number of cores and mm² per Outer diameter (mm) Copper index (kg/km) Weight (kg/km) conductor G 6 12, G 6 14, G 6 15, G G 10 17, G 10 19, G 10 21, G 16 20, G 16 22, G 25 25, G G 35 28, ELECTRICAL CHARACTERISTICS Current Ratings Table 1A - Current Carrying Capacity at 30 ºC NOMINAL CROSS SECTIONAL AREA mm² CURRENT RATING Amps The above table is a guide extracted from DIN VDE 0298 Part 4 and DIN 0100 Part 430 ( Table 11 Column 5)

5 Table 1B Conductor Resistances Nominal crosssection in mm 2 Conductor resistances at 20 C for 1 km in Ω (max. value) Made of wires with metal sheath Made of bare wires Class 2 Class Class 2 Class The above table is in accordance with BS EN (previously BS 6360) Table 1C Correction Factors For Multi core cables with conductor cross-sections up to 10mm² Number of cores under load 5 Conversion factor for installation in the open air Conversion factor for installation underground The above table is a guide extracted from DIN VDE 0298 Part 4 ( Table 26)

6 Table 1D Correction Factors for ambient temperatures other than 30 C Permissible/recommended operating conductor temperature Ambient temperature in C 60 C 70 C 80 C 85 C 90 C Conversion factors to be applied to the current rating values in Table 1A The above table is a guide extracted from DIN VDE 0298 Part 4 ( Table 17) All the information contained in this document - including tables and diagrams - is given in good faith and believed to be correct at the time of publication. The information does not constitute a warranty nor representation for which Byson Ltd assumes legal responsibility. Byson Ltd reserves rights to introduce changes to the document at any time.

Semoflex Roboschlepp The PUR cable for cable chains

Semoflex Roboschlepp The PUR cable for cable chains Semoflex Roboschlepp The PUR cable for cable chains Description Application For use in cable chains and continual moving machines and robots. Because of the polyurethane outer sheath the cable outer diameter

More information

PRODUCT INFORMATION ÖLFLEX ROBUST 215 C

PRODUCT INFORMATION ÖLFLEX ROBUST 215 C GmbH PRODUCT INFORMATION Proven all-weather control cables resistant to a wide range of chemical media Outstanding weather, ozone and UV resistance together with the wide temperature range enable versatile

More information

Halogen free cable. Halogen free cable

Halogen free cable. Halogen free cable SABIX Flame retardent Non Corrosive, FRNC, is an halogen free material based on Polyolefi n that fulfi lls the international norms (IEC) when it comes to fl ame propagation. These cables in different versions

More information

YSLY-JZ YSLY-OZ. Low voltage - Energy, cabling, signalling and control

YSLY-JZ YSLY-OZ. Low voltage - Energy, cabling, signalling and control Low voltage - Energy, cabling, signalling and control YSLY-JZ YSLY-OZ Construction: VDE Reg. n 7509 according to VDE 0281 Teil 13 according to DIN EN 50525-2-51 Flame propagation: DIN EN 60332-1-2 Low

More information

PUR cable. PUR cable. The harmonised version H05BQ-F/H07BQ-F can be used at building construction areas and where HAR-approval is required in Europe.

PUR cable. PUR cable. The harmonised version H05BQ-F/H07BQ-F can be used at building construction areas and where HAR-approval is required in Europe. Polyurethan (PUR) cables are suitable as control cables, for fl exible use where high mechanical stress occurs. The PUR outer jacket has very good resistance against mineral oils and different chemical

More information

MV-105 MEDIUM VOLTAGE CABLE. 5kV, 8kV, 15kV, 25kV & 35kV

MV-105 MEDIUM VOLTAGE CABLE. 5kV, 8kV, 15kV, 25kV & 35kV MV-05 MEDIUM VOLTAGE CABLE 5kV, 8kV, 5kV, 5kV & 5kV MV-05 MEDIUM VOLTAGE POWER CABLE 5kV % INSULATION LEVEL 8kV 00% INSULATION LEVEL Conductor conforming to ASTM B and Class B Compact stranded in accordance

More information

Extension and compensating cables, single-paired version - suitable for use in temperature measurement and manufacturing process control

Extension and compensating cables, single-paired version - suitable for use in temperature measurement and manufacturing process control PVC, silicone, FEP or glass fibre-insulated Extension and compensating cables, single-paired version - suitable for use in temperature measurement and manufacturing process control Info Available in many

More information

PRODUCT INFORMATION. Extension- and compensating cables, multi-paired

PRODUCT INFORMATION. Extension- and compensating cables, multi-paired PVC insulated - with and without steel wire armouring or foil screen Extension and compensating cables, multi-paired version - suitable for use in temperature measurement and manufacturing process control

More information

SADACHAIN CY PUR 1000 V

SADACHAIN CY PUR 1000 V SADACHAIN CY PUR 1000 V 80 C UR/CSA SCHERMATO/SHIELDED HIGH EFFICIENCY CARATTERISTICHE TECNICHE TECHNICAL FEATURES CONDUTTORE CONDUCTOR Rame flessibile Cl. 6 secondo CEI 20-29 DIN-VDE 0295 e IEC 60228

More information

SMARTen STP Patch Cords Features

SMARTen STP Patch Cords Features Features Patch Cords are used in the work area and cross-connect generic cabling applications Comprise a length of eight-wire flexible patch cable, terminated with two eight-position RJ-45 plugs at each

More information

Type MMV Medium Power Cable

Type MMV Medium Power Cable 7-05 Type MMV Medium Power Cable Single Conductor: 5kV 5kV, 00% & % Insulation Levels. Rated 90 C Multi-Conductor: 5kV 5kV, 00% & % Insulation Levels. Rated 90 C Conductors Soft annealed flexible stranded

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant

Comtran Cable. Commercial Premise & Specialty Datacom Products. Cat 5e - Cat 6A. LSZH & Industrial Ethernet. Indoor/Outdoor & Outside Plant Comtran Cable Commercial Premise & Specialty Datacom Products Cat 5e - Cat 6A LSZH & Industrial Ethernet Indoor/Outdoor & Outside Plant Category 6 : UL Type CMP : UL Type CMR Commercial Premise =====================================================================

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

Datasheet ANSI Type K & T Exposed Welded Tip Thermocouples (ANSI Colour Code)

Datasheet ANSI Type K & T Exposed Welded Tip Thermocouples (ANSI Colour Code) Datasheet ANSI Type K & T Exposed Welded Tip Thermocouples (ANSI Colour Code) ENGLISH Thermocouple types K & T to ANSI MC96.1 Fast response, welded exposed junction 1, 2, 5 or 10-metre-long Teflon PFA

More information

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11 Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double

More information

JUMO dtrans p30 Pressure Transmitter

JUMO dtrans p30 Pressure Transmitter 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 Phone: +44 179 6 55 Data Sheet 40466 Page 1/6 JUMO dtrans p0 Pressure Transmitter General application Pressure

More information

New, lighter, more flexible... MIG/MAG Fume Extraction Torch RAB Plus 501/501 D liquid-cooled. BINZEL. The right welding torch for every job!

New, lighter, more flexible... MIG/MAG Fume Extraction Torch RAB Plus 501/501 D liquid-cooled. BINZEL. The right welding torch for every job! MIG/MAG Fume Extraction Torch RAB Plus 501/501 D liquid-cooled New, lighter, more flexible... C E R DIN EN ISO 9001 Q M T - I F S I Y E T S D E M BINZEL. The right welding torch for every job! BINZEL liquid-cooled

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. E-11781 This is to certify that the Electric Power Cable with type designation(s) CS 90 MBZH YZp & & 0,6/1 kv, CS 90 MBZH YZafp 0,6/1 kv

More information

Pro-Tekt European Cable System. Technical Catalog

Pro-Tekt European Cable System. Technical Catalog European Cable System Technical Catalog High-Performance Cables for Demanding Applications Every cable application is important, and durable, long-lasting equipment requires rugged reliability. Downtime

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

Conductors. By far the largest and most important component of any earthing or structural lightning protection system is the actual conductor.

Conductors. By far the largest and most important component of any earthing or structural lightning protection system is the actual conductor. By far the largest and most important component of any earthing or structural lightning protection system is the actual conductor. Furse offer a comprehensive range of copper and aluminium conductors in

More information

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS

TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS TECHNICAL BULLETIN PINPOINT CONDUIT COUPLING AND SPLICING RECOMMENDATIONS CONTENTS: 1.0 General Information 2.0 Preparation and Splicing of PinPoint Wire 3.0 PinPoint Direct Bury Splice Kit Specifications

More information

The accuracy and safety of the connected measuring devices are directly regulated. of the introduced current transformers.

The accuracy and safety of the connected measuring devices are directly regulated. of the introduced current transformers. Product family Current transformers Current transformers (CTs) are introduced where it is difficult to access a direct measuring ot network current. Current transformer transforms the high network current

More information

User Manual V14.1 IP68 LED FLEX NEON

User Manual V14.1 IP68 LED FLEX NEON User Manual V14.1 IP68 LED FLEX NEON PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE END USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE 1/11 PRODUCT SPECIFICATION 1. Operating

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

PolySwitch Radial-leaded Resettable Devices

PolySwitch Radial-leaded Resettable Devices PolySwitch Radial-leaded Resettable Devices Radial-leaded Raychem Circuit Protection has pioneered PPTC technology for over twenty years. Our radialleaded products represent the widest range of product

More information

Prewired position switches FA series

Prewired position switches FA series Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:

More information

ENGLISH. Datasheet L60 Thermocouple & Fine Wire Welder

ENGLISH. Datasheet L60 Thermocouple & Fine Wire Welder Datasheet L60 Thermocouple & Fine Wire Welder ENGLISH The Thermocouple Welder is a compact, simple-to-use instrument designed for thermocouple and fine wire welding It is primarily designed for use by

More information

stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with encoder / brake

stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with encoder / brake stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with / brake / 9 www.igus.de MOT-AN-S_EN_2070# part number (not configurable, only for illustration)

More information

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code)

ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code) ENGLISH Datasheet IEC Miniature Thermocouple Connector Socket with Stainless Steel mounting bracket Types K, J, T, E, N, B & Copper (IEC Colour Code) Miniature size in-line Thermocouple Socket with stainless

More information

Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code)

Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code) Datasheet ANSI Standard Duplex Thermocouple Connector Sockets Types K, J, T, E, N, R/S & B (ANSI Colour Code) ENGLISH Duplex (2-channel) standard connector that accepts solid, round plug pins Bodies supplied

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary

More information

Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices

Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices Translation Principles of testing and certification for insulating hose assemblies on cable cutting devices Status as of 2014-01 Principles of testing Insulating hose assemblies on cable cutting devices

More information

ENGLISH Datasheet IEC PTFE Exposed Welded Tip Thermocouples with Miniature Thermocouple Plug

ENGLISH Datasheet IEC PTFE Exposed Welded Tip Thermocouples with Miniature Thermocouple Plug ENGLISH Datasheet IEC PTFE Exposed Welded Tip Thermocouples with Miniature Thermocouple Plug Thermocouple types K, J & T Fast response, welded exposed junction 1, 2, 5 or 10 metre lengths available Teflon

More information

SEALED CONNECTORS FOR THE LIMIT SWITCHES

SEALED CONNECTORS FOR THE LIMIT SWITCHES SEALED CONNECTORS FOR THE LIMIT SWITCHES LIST OF MODELS / Sealed connectors are used at the cable-connecting section of limit switches. Type and appearance Materials Features Target market Applications

More information

IEC Thermocouple Extension Leads with Miniature or Standard Thermocouple Connectors - Available in types K, J, T & N

IEC Thermocouple Extension Leads with Miniature or Standard Thermocouple Connectors - Available in types K, J, T & N Datasheet ENGLISH IEC Thermocouple Extension Leads with Miniature or Standard Thermocouple Connectors - Available in types K, J, T & N (Note: Illustration shows Type T with standard connectors and Type

More information

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co.

MEMS VOC Gas Sensor. (Model No.:GM-503A) Manual. Version: 1.0. Valid from: Zhengzhou Winsen Electronics Technology Co. MEMS VOC Gas Sensor (Model No.:GM-503A) Manual Version: 1.0 Valid from: 2015.12.1 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs to Zhengzhou Winsen Electronics

More information

will not support combustion

will not support combustion Strain Relief Grips Operating Temperatures Material Temperature Range Aluminum 40 C to +149 C ( 40 F to +300 F) Aluminum deluxe cord grips 34 C to +115 C ( 30 F to +240 F) Non-metallic deluxe cord grips

More information

Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code

Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code Datasheet IEC & ANSI Miniature or Standard Quick Wire Thermocouple Connector Plug & Socket Type K in IEC or ANSI Colour code ENGLISH These quick connect versions allow rapid termination Miniature connector

More information

Technical Datasheet. Rigid & Retractable Pendants. Rigid Pendant

Technical Datasheet. Rigid & Retractable Pendants. Rigid Pendant Rigid & Retractable Pendants Rigid Pendant Description Rigid pendants are intended for use operating theatres, anaesthetic rooms and similar medical locations. They are an ergonomic solution for the provision

More information

ibridge and ibridge Ultra

ibridge and ibridge Ultra 2.00 mm Board to Cable Connectors ED. 06 10.2016 Catalog EA IB001 erni.com erni.cn TABLE OF CONTENTS OVERVIEW General 03 Technical Details 04 Features 05 Electrical and Mechanical Characteristics 10 Ordering

More information

Amphenol. PowerLink Solar Cables. Amphenol 97 Series Connectors are UL recognized and CSA recognized.

Amphenol. PowerLink Solar Cables.   Amphenol 97 Series Connectors are UL recognized and CSA recognized. Amphenol PowerLink Solar Cables www.amphenol-industrial.com Amphenol 97 Series Connectors are UL recognized and CSA recognized. PowerLink Solar Cables Amphenol s single conductor PowerLink Solar Cables

More information

DT400/436 Tee Connector Installation Instructions

DT400/436 Tee Connector Installation Instructions Connectors Lorem ipsum and dolor Splices sit Amat Effective September 2014 Supersedes IS550-30-1 March 2011 MN650001EN DT400/436 Tee Connector Installation Instructions DISCLAIMER OF WARRANTIES AND LIMITATION

More information

Manual. MEMS Combustible Gas Sensor. Zhengzhou Winsen Electronics Technology Co., Ltd. (Model No.:GM-402B) Version: 1.0. Valid from:

Manual. MEMS Combustible Gas Sensor. Zhengzhou Winsen Electronics Technology Co., Ltd. (Model No.:GM-402B) Version: 1.0. Valid from: MEMS Combustible Gas Sensor (Model No.:GM-402B) Manual Version: 1.0 Valid from: 2015-12-01 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs to Zhengzhou Winsen Electronics

More information

MECHANICAL ASPECTS OF SUBMARINE CABLE ARMOUR

MECHANICAL ASPECTS OF SUBMARINE CABLE ARMOUR MECHANICAL ASPECTS OF SUBMARINE CABLE ARMOUR Ernesto Zaccone ARMORING OF SUBMARINE CABLES Submarine cables must be robust Mechanical aspects are at least as important as the electrical o nes Must withstand

More information

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations.

C&G 2395 Exam Paper April Section A - All questions carry equal marks. Answer all three questions. Show all calculations. C&G 2395 Exam Paper April 2013 Section A - All questions carry equal marks. Answer all three questions. Show all calculations. Q.1 The electrical installation in a small food retail outlet is scheduled

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

Conductor Bushings Series 8174

Conductor Bushings Series 8174 > Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The

More information

Electronic Instrumentation

Electronic Instrumentation Shielded multipair and multitriad - 00V - 105 C - PLTC - UL 1 Applications Electronic instrumentation, analog and digital signal circuits (-ma). Intrinsically safe circuits. Gas and/or fluid leak detection

More information

Check with local zoning official for property line distance requirements.

Check with local zoning official for property line distance requirements. RESIDENTIAL POOL PLAN SUBMITTAL GUIDELINES The following guidelines are intended to assist municipal residents with the permit acquisition process with regard to pools, spas and hot tubs for single family

More information

Operating Instructions

Operating Instructions Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2

More information

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT

More information

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e Mounting instructions Strain transducer SLB-700A B 26.SLB700A.10 e SLB700A 3 Contents Page Safety instructions.............................................. 4 1 Applications..................................................

More information

Deep Submersible Level Transducer Series 300DS

Deep Submersible Level Transducer Series 300DS KPSI Transducers Deep Submersible Level Transducer Series 300DS FEATURES! Custom Level Ranges up to 4614 ft (1408 m) H 2 O! Accuracy of ±0.5% FS! Analog Outputs of 4-20 ma or 0-5 VDC! Welded 316 SS Construction!

More information

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal

LK-SX CO 2 +VOC. Application. Security Advice Caution. Notes on Disposal LK-SX CO 2 +VOC Sensor for detection of carbon dioxide (CO 2) and mixed gas content in air ducts Data sheet Subject to technical alteration Issue date: 24.08.2015 Application For detection of CO2 and VOC.

More information

Erection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X

Erection, maintenance and disposal Inverted installation. Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X Erection, maintenance and disposal Inverted installation Zinc oxide silicone-housed surge arresters PEXLIM R-X, Q-X and P-X 1 Important information The following instruction is valid for PEXLIM R-X, PEXLIM

More information

Flex Cable Portfolio

Flex Cable Portfolio Flex Cable Portfolio More Flexibility in Cable Choice and Performance Alpha Wire s extensive line of flex cable is designed to deliver exceptional performance and reliability in the most strenuous of environments.

More information

Emergency Stop Devices/Rope Pull Switches

Emergency Stop Devices/Rope Pull Switches Rope pull switch with pulltoreset button for emergency stop device Metal housing Emergency stop device with detent mechanism according to EN ISO 13850 and EN 602041 Clamping head for pull rope Indication

More information

23.1 Functions, Basic Configuration, and Interfaces

23.1 Functions, Basic Configuration, and Interfaces 23 (6.6.D) SF 6 and Other Special Gases 23.1 Functions, Basic Configuration, and Interfaces 23.1.1 Functions The primary function performed by the SF 6 and other special gases system is to provide SF 6

More information

Installation Guideline for Placing Fiber Optic Cable into an Underground Duct

Installation Guideline for Placing Fiber Optic Cable into an Underground Duct Installation Guideline for Placing Fiber Optic Cable into an Underground Duct Table of Contents A. Purpose... 1 B. Introduction...2 C. General Precautions...2 D. Reference Documents...3 E. Fiber Optic

More information

EASIDEW TRANSMITTER with Current Source Output

EASIDEW TRANSMITTER with Current Source Output EASIDEW TRANSMITTER with Current Source Output INSTALLATION, OPERATION AND MAINTENANCE MANUAL Issue March 2002 2 TABLE OF CONTENTS SECTION PAGE 1. INTRODUCTION 3 1.1 General 3 1.2 Ceramic Sensing Element

More information

INDEX OF REVISIONS DESCRIPTION AND/OR AFFECTED SHEETS

INDEX OF REVISIONS DESCRIPTION AND/OR AFFECTED SHEETS E&P-CORP/ ENGP/ISP TECHNICAL SPECIFICATION I-ET-3500.00-1500-896-PAZ-002 Rev. 0 E&P Pag. 1 / 13 UN-BC e UN-RIO SUBSEA CONTROL UMBILICAL (Manifold Standard) INDEX OF REVISIONS REV DESCRIPTION AND/OR AFFECTED

More information

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations. C&G 2395 Exam Paper June 2013 Section A-All questions carry equal marks. Answer all three questions. Show all calculations. 1. The electrical installation in an industrial unit is scheduled for a periodic

More information

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS DESIGNED TO HOLD THE WEIGHT FOR ELECTRICAL CABLE AS IT HANGS IN VERTICAL, SLOPING OR HORIZONTAL POSITIONS. EASILY INSTALLED AND REMOVED USING NO

More information

Technical Data. General specifications. Rated operating distance s n 2 mm

Technical Data. General specifications. Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation

More information

Accessories. Finger Guards 134. Filter Guards grille 139. Accessories 140. Technology. DC Axial Fans. DC Radial Fans. Specials.

Accessories. Finger Guards 134. Filter Guards grille 139. Accessories 140. Technology. DC Axial Fans. DC Radial Fans. Specials. 13 Technology Finger Guards 134 Filter Guards grille 139 140 Specials DC Axial Fans DC Radial Fans Everything that you need for your fan. ebm-papst provides an extensive range of accessories for optimum

More information

Picture. Minimum cable bending radius 100 mm [4"] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables)

Picture. Minimum cable bending radius 100 mm [4] < 400 N [90 lbf] (PE / PUR cables) < 15 N [3.4 lbf] (FEP cables) Type: for level measurement Order No.: see Table 1 / Page 4 Features Picture Two wire system Piezoresistive measuring element Output signal 4-20 ma Conformity error ±0.5 % FS or Standard DIN measuring

More information

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT IEC 649 COMPLIANT METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES INTRODUCTION Current transformer open circuit protection with reliability, flexibility and expertise built-in. Current Transformer

More information

Lightning and surge protection for yachts

Lightning and surge protection for yachts 934 Lightning and surge protection for yachts r Yachts at sea, at anchor and ashore (e.g. in a dry dock) are vulnerable to lightning strikes. The probability of a lightning strike depends on the local

More information

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH THIS MANUAL IS INTENDED FOR TECHNICAL STAFF IN CHARGE OF THE INSTALLATION, THE OPERATION AND THE MAINTENANCE OF THIS PRODUCT CAUTION!

More information

The definition of a competent person given in the Electricity at Work Regulations 1989 (EWR) is as follows:

The definition of a competent person given in the Electricity at Work Regulations 1989 (EWR) is as follows: Electrical Safety Guidance Note 1 - General Guidance Competent Person The definition of a competent person given in the Electricity at Work Regulations 1989 (EWR) is as follows: "A person in the possession

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

ES18 Security Theory/Regulations Answer Schedule

ES18 Security Theory/Regulations Answer Schedule ES18 Security Theory/Regulations Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The marker

More information

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS Pull-rope emergency stop switch Type OPERATING INSTRUCTIONS Legal Notice (Translation of the original) Document No.: 94.058 816.191 Pull-rope emergency stop switch, Type HENEX and SEGEX Product number:

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit

More information

Electrical. Version 1.0

Electrical. Version 1.0 This document is intended to provide basic safety guidelines for the Physical Plant Department at Community College of Allegheny County. The information provided in this guide may vary by site. Version

More information

GENERAL APPLICATION NOTES

GENERAL APPLICATION NOTES GENERAL APPLICATION NOTES There are common considerations when using our connectors. Additional considerations may apply based on the particular connector being used, the application, and conditions in

More information

The SAG type flat, rubber-steel, balance ropes

The SAG type flat, rubber-steel, balance ropes ROPES The SAG type flat, rubber-steel, balance ropes Application of the SAG ropes: The SAG type, flat, rubber-steel balance ropes, further on called the SAG ropes, are used for shaft transport at mines

More information

Examination lamps OBSERVA ALFALED A06 L88 ALFA

Examination lamps OBSERVA ALFALED A06 L88 ALFA Examination lamps OBSERVA ALFALED A06 L88 ALFA Light plays a major role in the medical field, being required to provide a faithful image of what the doctor sees during observation. 2 Light plays a major

More information

Primary Terminals & Connectors

Primary Terminals & Connectors Primary & Pure electrolytic copper with electro-tin plating for corrosion resistance Deep internal serrations promote firm wire grip for maximum strength Insulation (where applicable) is color coded to

More information

Plastic tubing, standard O.D.

Plastic tubing, standard O.D. Plastic tubing, standard O.D. Plastic tubing, standard O.D. Features Application The requirements with respect to pressure, temperature, flexibility and environmental influences differ from industry to

More information

Code of Practice for the Inspection and Testing of Portable Electrical Equipment (PAT)

Code of Practice for the Inspection and Testing of Portable Electrical Equipment (PAT) Code of Practice for the Inspection and Testing of Portable Electrical Equipment (PAT) Reviews and Revisions Action Date Reason Reviewer Updated details of External PAT Contractor 17/02/16 New contract

More information

PRODUCTS CATALOG

PRODUCTS CATALOG 2017-2018 PRODUCTS CATALOG THE BROADEST LINE OF QUALITY ELECTRICAL FITTINGS & TUBULAR PRODUCTS PLUS THE BEST PERFORMANCE GUARANTEE IN THE INDUSTRY ABOUT US Electroline is committed to manufacturing quality

More information

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential Pressure Control Types MP 54, MP 55 and MP 55A MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration

More information

TBi RM 50 G. RoboMIG 1.1. Technical data. Robot welding torch TBi RM 50 G

TBi RM 50 G. RoboMIG 1.1. Technical data. Robot welding torch TBi RM 50 G RoboMIG TBi RM 50 G Technical data Robot welding torch TBi RM 50 G Short gas nozzle for better accessibility Rating at 60% duty cycle (10 min. cycle) - Mixed gas: 8.8 kw (approx. 250-280 A) Cooling method

More information

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet

LK-SX VOC. Application. Security Advice Caution. Notes on Disposal. Combined sensor mixed gas. Data sheet LK-SX VOC Combined sensor mixed gas Data sheet Subject to technical alteration Issue date: 24.08.2015 Application The sensor detects air quality in ventilation ducts. A stronger output signal of the sensor

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

FLEXIBLE AND RELIABLE ANCHORING

FLEXIBLE AND RELIABLE ANCHORING Spiral rope anchor and FLEX Head FLEXIBLE AND RELIABLE ANCHORING 1 THE SMARTER ANCHOR FLEXES. The flexibility of the whole system is crucial for both rockfall barriers and other protection systems. Why?

More information

ISO INTERNATIONAL STANDARD. Cranes and lifting appliances Selection of wire ropes Part 1: General

ISO INTERNATIONAL STANDARD. Cranes and lifting appliances Selection of wire ropes Part 1: General INTERNATIONAL STANDARD ISO 4308-1 Third edition 2003-05-01 Cranes and lifting appliances Selection of wire ropes Part 1: General Grues et appareils de levage Choix des câbles Partie 1: Généralités Reference

More information

INSTALLATION INFORMATION

INSTALLATION INFORMATION This publication contains a collection of general information related to the installation of power cables. The design of power cable installations and installation of power cables should be done by competent

More information

Differential pressure switch MP 54, MP 55 and MP 55A

Differential pressure switch MP 54, MP 55 and MP 55A Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating

More information

FIRE PREVENTION METHOD FOR 275KV OIL-FILLED CABLE IN TEPCO

FIRE PREVENTION METHOD FOR 275KV OIL-FILLED CABLE IN TEPCO FIRE PREVENTION METHOD FOR 275KV OIL-FILLED CABLE IN TEPCO Atsushi Toya, Tokyo Electric Power Company, (Japan), toya.atsushi@tepco.co.jp Shinsuke Nasukawa, Tokyo Electric Power Company, (Japan), nasukawa.shinsuke@tepco.co.jp

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option MANUAL DIRECT PURGE OPTION UNION Instruments GmbH CWD2005 PLUS General information, safety standards and regulations for direct purge option Version: V1.00 Stand: 24.03.2010 Union Instruments GmbH Zeppelinstr.

More information

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications. Sanitary RTD Temperature sensor TH17 Compact Instructions Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications. The single element RTD is specifi cally designed

More information

Residential Swimming pools

Residential Swimming pools City of Republic Community Development Department Residential Swimming pools REVISION DATE: JANUARY 2017 Swimming Pool Safety Definitions: Barrier Requirements: A) Application All swimming pools over 24

More information

GENERAL CATALOGUE 2O16

GENERAL CATALOGUE 2O16 GENERAL CATALOGUE 2O16 LABORATORY TAPS INDEX TECHNICAL INFORMATION PAGES DRY SERVICE CONTROLS PAGES PRESENTATION TECHNICAL INFORMATION DESIGN AND MANUFACTURING 1 2-3 4 BENCH MOUNTED WALL MOUNTED PENDANT

More information

RTD Temperature sensor TH11

RTD Temperature sensor TH11 RTD Temperature sensor TH11 Compact Instructions Measuring System General purpose RTD with connection head TH11 for process and laboratory applications. The single element RTD is specifi cally designed

More information