Combining NEG pumps and an XHV BNNT cryopump
|
|
- Virgil Chandler
- 5 years ago
- Views:
Transcription
1 Combining NEG pumps and an XHV BNNT cryopump Marcy L. Stutzman, Anahí Segovia Miranda, Veronica Over, Philip Adderley, Matt Poelker Thomas Jefferson National Accelerator Facility Newport News, VA 23601, USA
2 Thomas Jefferson National Accelerator Facility US Department of Energy, 12 GeV electrons, recirculating linear accelerator Up to 90% polarization from DC photoemission source Electron currents to 200μA beam (CW) to four experimental halls Source Hall D (0.012 TeV) Halls A, B, C Polarized source 2
3 -100 to -350 kv DC Photoemission Source cathode electrode anode (ground) light in electrons out 14 layers GaAsP Strained Superlattice Photocathode GaAs GaAs Polished high voltage electrodes Strained superlattice GaAs/GaAsP photocathode Surface preparation: Cs, NF 3 Electron beam polarization ~90% Residual gasses ionized, limit operational lifetime Base pressure approaching XHV P < 1x10-10 Pa 3
4 Vacuum research to extend lifetime Add NEG array to original ion pumped system C. K. Sinclair et al., "A High Average Current Polarized Electron Source with Long Cathode Operational Lifetime", Phys. Rev. ST Accel. Beams 10, (2007) Outgassing reduction M.A. Mamun, et al., "Effect of heat treatments and coatings on the outgassing rate of stainless steel chambers, Journal of Vacuum Science & Technology A 32, (2014) NEG coating large diameter chamber M. L. Stutzman et al., "Nonevaporable getter coating chambers for extreme high vacuum," J. Vac. Sci. Technol. A 36, (2018) Incorporating additional XHV cryo-pumping in the system? Leybold XHV cryopump Boron Nitride Nanotubes (BNNT) as cryosorber Marcy Stutzman, Roy Whitney and Kevin Jordan Nano-materials for adhesive-free adsorbers for bakable extreme high vacuum cryopump surfaces Patent US B2 4
5 Cryopumps typically not bakable XHV Cryopumping Adhesives for charcoal cryosorption surface Mechanics of closed-cycle helium refrigerators Solutions other places: Charcoal with Bakable adhesives (Silversolder or Thermoguss) KEK: 2K helium flow Our research Leybold bakable cryopump LN 2 chill circuit to keep charcoal, adhesive, mechanics cold during vacuum bakeout Valve outgassing mitigates pump effect Alternatives to Charcoal not requiring adhesive? Boron nitride nanomaterial as cryosorber material 5
6 Freestanding boron nitride nanotubes Chemically inert Very porous structure Thermal Conductivity 3000 W/mK vs. Cu = 400 W/mK, Investigate potential as bakeable cryosorber Fibril BNNT material 1 g BNNT 10 g CNT (similar scale) 6
7 Boron Nitride NanoTubes Freestanding cryosorber Retaining wire tack welded - no adhesive 1g = 300 m 2 surface area Total 4.4g BNNT, ~1000 m 2 Novel Cryopump: BNNT Attachment on both sides of fins Cryopump base temperature ~12.5 K US Patent issued October
8 Pressure (Torr) Cryopump Temperature (K) BNNT Cryopump performance: First and Second builds First build 1g BNNT Copper retaining mesh Base temp 15K heat load due to mesh Ion pump + BNNT CP Second Build 4g BNNT Tack welded wires Base temperature 12.5K Ion pump L/s NEG + BNNT CP 1.E-06 1.E-07 1.E-08 1.E-09 1.E-10 1.E-11 1.E-12 4g BNNT 1g BNNT T Hours
9 Chamber Pressure (Torr) Pump Speed (L/s) BNNT Cryopump speed and capacity, 4g BNNT 9E-11 8E-11 7E-11 6E-11 5E-11 4E-11 3E-11 2E-11 1E Pump speed setup hydrogen gas conductance limiting orifice pressure ~10-11 Torr Pump capacity S = S 1/e capacity ~0.03 TorrL Commercial cryopump: Very open porous structure High pump speed Low pump capacity Gas dose (TorrL) 0 9
10 Pressure (Torr) BNNT cryopumping 1.E-07 1.E-08 1.E-09 1.E-10 Add BNNT CP to NEG/ion pump chamber 1.E-11 1.E-12 1.E-13 1g 4g 4g + NEG array Pwarm Pcold??? Base pressure ~10-12 Torr before cooling cryopump 10
11 System setup for BNNT Cryopump + NEG pump system Heat treated stainless steel Outgassing rate ~5x10-13 TorrL/s/cm 2 NEG pump array 10 WP950 ST707 modules Ion pump Gamma XHV/SEM 40 L/s Extractor and 3BG gauges BNNT Cryopump 4g BNNT cryosorber Remove displacer for bake Bake system to 250 C, 30 hours with turbopump cart Turn on gauges, Measure pressure* Ion pump NEG array Gauges NEG array BNNT Cryopump 11
12 Gauges for XHV Extractor gauge x-ray limit reduced through geometry Extractor Watanabe 3BG (Bent Belt Beam) gauge 230 deflector BeCu housing JVSTA 28, 486 (2010) 3BG 12
13 Extractor current (fa) x-ray induced current of gauges Collector current (fa) Extractor Gauge Bent Belt Beam Gauge Signal: background 30: x-ray background 10 5 x-ray background 0 Signal: background 1: Repeller voltage (V) Deflector voltage (V) Other background effects: ESD, gauge heating/pumping
14 Pressure (Torr) 7.E-12 6.E-12 5.E-12 4.E-12 3.E-12 2.E-12 1.E-12 0.E E E-12 NEG+IP+CP Warm Results Before x-ray subtraction after 5.1E-13 Extractor - x-ray limit 3BG 3.3E-12 NEG+CP cold BNNT outgassing low No valve P~3x10-12 Torr BNNT warm Cryopump reduces pressure x-ray limit 1.2x10-12 Torr dominates extractor gauge reading 3BG readings still have good signal:background, negligible x-ray effect 14
15 Recorded pressure (Torr) x-ray limit measurements with BNNT cryopump warm and cold 8E-12 7E-12 6E-12 5E-12 4E-12 3E-12 2E-12 1E-12 Repeated x-ray limit measurements, cryopump warm x-ray limit measurement, cryopump cold averaged x-ray limit Voltage applied to reflector (V) Are we at, or beyond extractor measurement limitation? 15
16 Extractor Pressure (Torr) Extractor vs. 3BG calibration issues 1E-09 1E-10 1E-11 1E-12 1E-13 1E-13 1E-12 1E-11 1E-10 1E-09 3BG Pressure (Torr) Good gauge agreement >10-11 Torr Diverge by 1x10-12 Torr x-ray limit of Torr subtracted from extractor 3BG has good signal to noise, never reads below Torr Limitations? Electrometer resolution Other background in 3BG? 16
17 Next steps and conclusions CP cold CP warm Preliminary Molflow simulations to model outgassing rate and pump speed / sticking coefficient Warm: outgassing Cold: sticking coefficient Potential for XHV cryopumping Low capacity, but XHV applications include high current polarized electron sources erhic 5e-13 5e-11 Ionization gauges at XHV are complicated at pressure 1000x below calibration points Looking for a paradigm shift in XHV pressure measurement (NIST?) 17
18 Acknowledgements U.S. DOE Contract No. DE-AC05-06OR23177 and with funding from the DOE R&D for Next Generation Nuclear Physics Accelerator Facilities Funding Opportunity Number: DE-FOA Jefferson Lab Center for Injectors and Sources Staff: Matt Poelker, Joe Grames, Don Bullard, Marcy Stutzman, John Hansknecht, Shukui Zhang, Carlos Hernandez Garcia, Philip Adderley, Riad Suleiman, Md. Abdullah Mamun (post-doc). Students: Yan Wang, Gabriel Palacios Serrano, Sajini Wijethunga, Joshua Yoskowitz, Anahi Miranda Segovia, Veronica Over 18
19 Backup 19
20 BNNT properties TEM Purity Residual Walls Tube Length Surface Area 40 to 50% by mass hbn flakes and micro-droplets of elemental boron, by TEM 1 to 5 walls, mostly 2 or 3 walled tubes up to 200 microns by SEM up to 300 m 2 /g by BET Bundles single through bundles of 5 tubes, TEM Impurities: B and hbn / pdf Band Gap Strength in air Thermal oxidation resistance Thermal Conductivity 5.7 ev (semiconducting) EELS spectroscopy 800 C (CNT is 400 C) Stable to at least 920 C in air 3000 W/mK (Cu = 400 W/mK, CNT 60-40,000 W/mK) 20
21 NEG array + Room Temperature Cryopump Stainless steel outgassing rate 5x10-13 TorrLs -1 cm -2 NEG pumps fully activated, WP950 ST 707, 525 L/s each Outgassing rate of fins adjusted to reach measured pressure of 5.2e-12 Torr on 3BG BNNT outgassing rate 5e-12 Torrl/s/cm^2 effective 21
Assembling NEG, Ion Pump and Bakeable BNNT Cryopump System to Reach XHV
Assembling NEG, Ion Pump and Bakeable BNNT Cryopump System to Reach XHV Anahí Segovia Miranda Universidad Autónoma de Zacatecas Unidad Académica de Física Marcy Stutzman Thomas Jefferson National Accelerator
More informationExtreme High Vacuum: The Need, Production, and Measurement
Extreme High Vacuum: The Need, Production, and Measurement, Philip Adderley, Matt Poelker (Jefferson Lab) Polarized Electron Gun Group Newport News, Virginia Run by JSA for the US DOE What is XHV Extreme
More informationGun Vacuum Performance Measurements February 2003
JLAB-TN-03-013 Gun Vacuum Performance Measurements February 2003 Marcy Stutzman Abstract. The vacuum in the polarized photoguns at Jefferson Lab is crucial to long lifetime operation of the polarized source.
More informationPractical approach and problems in in-situ RGA calibration
Practical approach and problems in in-situ RGA calibration Oleg Malyshev and Keith Middleman Vacuum Science Group, ASTeC Accelerator Science and Technology Centre STFC Daresbury Laboratory UK Workshop
More informationTests for High Voltage & Vacuum of the 2 nd 500 kv DC Gun at KEK
Tests for High Voltage & Vacuum of the 2 nd 500 kv DC Gun at KEK OLAV IV @NSRRC 3 rd April 2014 Masahiro Yamamoto KEK 2 nd DC-gun Development Team T. Miyajima, Y. Honda, T. Uchiyama, M. Kobayashi, Y. Saito,
More informationNon-evaporable getter coating chambers for
Non-evaporable getter coating chambers for extreme high vacuum Running title: NEG coating chambers for XHV Running Authors: M. L. Stutzman, P. A. Adderley, M. A. Mamun and M. Poelker Marcy L. Stutzman
More informationVacuum Simulations of the KATRIN Experiment
Vacuum Simulations of the KATRIN Experiment Marcel Krause (KATRIN collaboration) 31.03.2014 KIT University of the State of Baden-Wuerttemberg and National Research Center of the Helmholtz Association www.kit.edu
More informationIntroduction of Vacuum Science & Technology. Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project.
Introduction of Vacuum Science & Technology Diffusion pumps used on the Calutron mass spectrometers during the Manhattan Project. 1 What is a vacuum? 760 mm Hg Vacuum ATM A vacuum is defined as less than
More informationShort Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.
Short Introduction to Cryo-Pumps and Refrigerators Dr Graham Rogers Leybold UK Ltd. Cryo Pumps Topics Physical principles of cryo-pumping Design and control of modern refrigerator cryo-pumps UHV and XHV
More informationA Road Map to Extreme High Vacuum
A Road Map to Extreme High Vacuum Philip Adderley, Ganapati Myneni Jefferson Lab 12000 Jefferson Ave, Newport News, VA; 23606 adderley@jlab.org, rao@jlab.org Abstract. Ultimate pressure of a well-designed
More informationVacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007
Vacuum Science Techniques and Applications Dan Dessau Adv. Lab 2007 Vacuum increases the mean-free-path of gas molecules. Vacuum prevents chemical reaction. Vacuum removes contaminants from surfaces. Vacuum
More informationNumerical Tools for LCLS-II Vacuum Systems
Numerical Tools for LCLS-II Vacuum Systems G. Lanza, D. Gill, SLAC National Accelerator Laboratory AVS, November 2 nd 2017 Doc. N. SLAC-PUB-17166 Work described in this presentation is supported by the
More informationThe Principles of Vacuum Technology
The Principles of Vacuum Technology Vacuum Terminology Vacuum units Vacuum regimes How to measure vacuum. Gauge designs. How to create vacuum Pump classifications and designs UHV compatibility considerations
More informationResist round robin ELETTRA
Resist round robin outgassing @ ELETTRA Trieste - Italy M. Bertolo, P. Lacovig, L.Rumiz, D. Giuressi, R. Sergo, A. Stolfa Experimental setup (1) 100 mm linear translator Sample manipulator Mask manipulator
More informationThe Broadest Gauging Line in the Industry
The Broadest Gauging Line in the Industry Vacuum Measurement Varian s broad line of vacuum gauge controllers and gauge tubes are the most reliable, accurate, and economical means of measuring, monitoring,
More informationUltrahigh Vacuum in Superconducting Synchrotrons A.Smirnov, JINR, Dubna, Russia
Ultrahigh Vacuum in Superconducting Synchrotrons A.Smirnov, JINR, Dubna, Russia Topics: - Pumping & outgasing of hydrogen - Cryogenic pumps & non evaporable getters for UHV - Superconducting accelerators:
More informationVacuum Science and Technology in Accelerators
Vacuum Science and Technology in Accelerators Ron Reid Consultant ASTeC Vacuum Science Group (ron.reid@stfc.ac.uk) Session 5 Materials Properties Relevant to Vacuum Aims To understand which mechanical
More informationThis educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum.
This educational seminar discusses creating, measuring, and troubleshooting Rough Vacuum. Specifically, today s talk will cover: Brief review of Vacuum Fundamentals Applications Using Rough Vacuum Rough
More informationat NIST: ultra-low outgassing rates
Traceable outgassing measurements at NIST: ultra-low outgassing rates and new materials James Fedchak Thermodynamic Metrology Group Sensor Science Division Physical Measurement Laboratory Vacuum Project:
More informationBEST KNOWN METHODS. Transpector XPR3 Gas Analysis System. 1 of 6 DESCRIPTION XPR3 APPLICATIONS PHYSICAL INSTALLATION
BEST KNOWN METHODS Transpector XPR3 Gas Analysis System DESCRIPTION The Transpector XPR3 is a third-generation, quadrupole-based residual gas analyzer that operates at PVD process pressures and is the
More informationThe Experts in Vacuum Solutions
By Woodrow Farrow - Reprinted with permission from Specialty Gas Report Vacuum: a space that is relatively empty of matter, especially when that void has been created through artificial means. The earth
More informationDC gun high voltage conditioning with Krypton gas Carlos Hernandez-Garcia October 2008
DC gun high voltage conditioning with Krypton gas Carlos Hernandez-Garcia October 2008 Index Background 1 High voltage processing with Helium gas 2 High voltage processing with Krypton gas 3 Some thoughts
More informationDevelopment of Cleaning and Processing Techniques for UHV/XHV at Daresbury Laboratory Keith Middleman
Development of Cleaning and Processing Techniques for UHV/XHV at Daresbury Laboratory Keith Middleman ASTeC Vacuum Science Group STFC Daresbury Laboratory Accelerators + Vacuum Particle accelerators come
More informationChoosing a Quadrupole Gas Analyzer Application Note #9
Choosing a Quadrupole Gas Analyzer Application Note #9 Modern-day contamination control requirements for gas phase processes are constantly pushing the limits of performance of quadrupole gas analyzers.
More informationAchieving Ultra-High Vacuum without (in-situ) Bakeout
Achieving Ultra-High Vacuum without (in-situ) Bakeout Matthew Cox Diamond Light Source, UK WS 63 Ávila September 2010 1 What is Diamond Light Source? The UK national synchrotron facility 3 rd generation
More informationDr. José Miguel JIMENEZ CERN, Technology Department Head of the Vacuum, Surfaces and Coatings group
Vacuum Systems Outline Vacuum in Particle Accelerators Vacuum Basics Instrumentation & Pumping The LHC Case Vacuum in Particle Accelerators Why is Vacuum needed in particle accelerators? Vacuum aims to
More informationVacuum System at IUAC
Vacuum System at IUAC A. Mandal Inter-University Accelerator Centre, Aruna Asaf Ali Marg, Post Box - 10502, New Delhi 110067, Fax:011-26893666. email: mandal@iuac.res.in Abstract: Vacuum technology is
More informationAPPLICATION OF A CHANNEL PLATE IN FIELD-ION MICROSCOPY
R 718 Philips Res. Repts 25, 87-94,1970 APPLICATION OF A CHANNEL PLATE IN FIELD-ION MICROSCOPY by A. van OOSTROM Abstract Further progress has been made in applying a channel-plate image intensifier in
More informationA Journal of Practical and Useful Vacuum Technology. By Phil Danielson
A Journal of Practical and Useful Vacuum Technology From By Phil Danielson Thermal Conductivity Gauges Thermal conductivity pressure gauges are extremely common in vacuum technology, but an understanding
More informationGraphite and C-C materials for UHV applications
Graphite and C-C materials for UHV applications Prepared by J.M. JIMENEZ AT/VAC/SL Section Graphite Outgassing Measurements for UHV Applications Main topics What did we learn from past experiences? Static
More informationTotal Pressure Measurement Using Residual Gas Analyzers
Total Pressure Measurement Using Residual Gas Analyzers M. Maskell, Old Dominion University; G. Myneni, P. Adderley, Jefferson Lab; G. Brucker, Stanford Research Systems; C. Day, Forschungszentrum, Karlsruhe
More informationMASSIVE TITANIUM SUBLIMATION PUMPING IN THE CESR INTERACTION REGION *
MASSIVE TITANIUM SUBLIMATION PUMPING IN THE CESR INTERACTION REGION * N.B. Mistry, R. Kersevan and Yulin Li, Laboratory of Nuclear Studies, Cornell University, Ithaca, NY 153 USA Abstract * The residual
More informationThe ERL Injector Project at Cornell University
The ERL Injector Project at Cornell University Bruce Dunham For the Cornell ERL Team Jefferson Lab Seminar December 4, 2007 CESR at Cornell December 4, 2007 B. Dunham December 4, 2007 2 ERL at Cornell
More informationThis educational seminar discusses creating, measuring, and troubleshooting Ultra-High Vacuum ( Torr) systems.
This educational seminar discusses creating, measuring, and troubleshooting UltraHigh Vacuum ( 10 8 10 12 Torr) systems. Specifically, today s talk will cover: Brief review of High Vacuum (Characteristics,
More informationRemote Plasma Cleaning from a TEM Sample Holder with an Evactron De-Contaminator ABSTRACT
Remote Plasma Cleaning from a TEM Sample Holder with an Evactron De-Contaminator Christopher G. Morgan, David Varley, and Ronald Vane, XEI Scientific, Inc., 1755 E. Bayshore Rd., Suite 17, Redwood City,
More informationGranville-Phillips Series 370 Stabil-Ion Vacuum Gauge Controller
Granville-Phillips Series 370 Stabil-Ion Vacuum Gauge Controller All-metal, rack-mount controller for Stabil-Ion and Convectron vacuum gauges is noise-immune and CE compliant Accurate vacuum pressure measurement
More informationLCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory
UCRL-TR-223160 LCLS-TN-06-12 July 12, 2006 LCLS Heavy Met Outgassing Tests * K. I. Kishiyama, D. M. Behne Lawrence Livermore National Laboratory Abstract A Heavy Met that is 95% tungsten, 3% nickel and
More informationIntroductory Lab: Vacuum Methods
Introductory Lab: Vacuum Methods Experiments in Modern Physics (P451) In this lab you will become familiar with the various components of the lab vacuum system. There are many books on this topic one of
More informationOMNISTAR / THERMOSTAR. The efficient solution for gas analysis. Intelligent software. Wide range of applications.
OMNISTAR / THERMOSTAR The efficient solution for gas analysis. Intelligent software. Wide range of applications. OMNISTAR /THERMOSTAR The efficient solution for gas analysis. Intelligent software. Wide
More informationTechnical Specifications of Hydrogen Isotope Handling and Recovery System
SECTION - C TECHNICAL SPECIFICATIONS OF STORES AND DRAWINGS. Technical Specifications of Hydrogen Isotope Handling and Recovery System INSTITUTE FOR PLASMA RESEARCH GANDHINAGAR, GUJARAT 382428 ANNEXURE-I
More informationAn Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler
An Investigative and Synoptic Review on Helium Liquefaction Using a Commercial 4 K Gifford- McMahon Cryocooler Mahesh N 1, S A Mohan Krishna 2 1 PG Student, Vidyavardhaka College of Engineering, Mysore,
More informationOutgas of Methane from NEG Coating
WS63: SURFACE PHENOMENA LIMITING PRESSURE IN VACUUM SYSTEM Outgas of Methane from NEG Coating Chia-Mu Cheng ( 鄭家沐 ) Vacuum Group NSRRC, Taiwan 18 /09/2010 e-mail : chiamucheng@nsrrc.org.tw 1 Application
More informationContamination Removal of EUVL masks and optics using 13.5-nm and 172-nm radiation
Contamination Removal of EUVL masks and optics using 13.5-nm and 172-nm radiation Takeo Watanabe, Kazuhiro Hamamoto and Hiroo Kinoshita University of Hyogo IEUVI Resist & Contamination TWG Oct.19, 2006
More informationHow To Use Getters and Getter Pumps
A Journal of Practical and Useful Vacuum Technology From By Phil Danielson How To Use Getters and Getter Pumps Gettering is a vacuum pumping technology that has been with us, in many forms, for almost
More informationFig. 1: Mechanical vacuum gauge (left) and capacitive vacuum gauge (right)
Dear Readers! This is your 4pvd Newsletter. We hope you enjoy the information it contains. If you wish to unsubscribe, please send a blank Email to unsubscribe@4pvd.de June 1 st, 2006, Issue No. 24 Principles
More informationSelection of Materials and Processes for Space Use. Ruben Edeson, Mechanical Engineer, SSTD.
Selection of Materials and Processes for Space Use Ruben Edeson, Mechanical Engineer, SSTD. Materials Selection for Space Mechanical properties, ie specific stiffness Thermal and optical properties Cost
More informationApproved by Principal Investigator Date: Approved by Super User: Date:
Approved by Principal Investigator Date: Approved by Super User: Date: Standard Operating Procedure BNC Commonwealth Dual Ion Beam Deposition System (CDIBS) Version 2010 February 14 I. Purpose This Standard
More informationA novel class of Non Evaporable Getter (NEG) alloys with lower hydrogen equilibrium pressure and reduced outgassing properties
A novel class of Non Evaporable Getter (NEG) alloys with lower hydrogen equilibrium pressure and reduced outgassing properties P. Manini, FabrizioSiviero, A. Gallitognotta, L. Caruso, T. Porcelli,G. Bongiorno,
More informationETCHING OF COPPER COATED MYLAR TUBES WITH CF4 GAS. Karl M. Ecklund, Keith W. Hartman, Michael J. Hebert, Stanley G. Wojcicki
SLAC-PUB-16219 ICFA INSTRUMENTATION B ULLETIN ETCHING OF COPPER COATED MYLAR TUBES WITH CF4 GAS Karl M. Ecklund, Keith W. Hartman, Michael J. Hebert, Stanley G. Wojcicki Department of Physics, Stanford
More informationLeak Detection. Kirsten Zapfe, DESY CAS Vacuum in Accelerators Platja D Aro, May 21, Special thanks to S. Holm, N. Mildner and A.
Leak Detection, DESY CAS Vacuum in Accelerators Platja D Aro, May 21, 2006 Special thanks to S. Holm, N. Mildner and A. Wagner Outline Introduction Leak Rate and Leak Types Leak Detection Methods Helium
More informationInstrumentation & Data Acquisition Systems
Instrumentation & Data Acquisition Systems Section 4 - Pressure Robert W. Harrison, PE Bob@TheHarrisonHouse.com Made in USA 1 Definition of Pressure Pressure is the amount of force applied perpendicular
More informationCharacteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers
Characteristics and Production of Gas Sealed, Radiation Hard, Small Ionization Chambers Mayda Velasco 1 Gianni Tassotto 3 on behalf of the SIC team P. Ball 2, A.Dabrowsky 1, G. Graham 2, C. Kendziora 3,
More informationIUVSTA WORKSHOP WS-63 Surface Phenomena Limiting Pressure in Vacuum Systems REPORT TO IUVSTA. prepared by JOSÉ L. DE SEGOVIA
IUVSTA WORKSHOP WS-63 Surface Phenomena Limiting Pressure in Vacuum Systems INTRODUCTION REPORT TO IUVSTA prepared by JOSÉ L. DE SEGOVIA on behalf of the SPANISH VACUUM SOCIETY Madrid,February 1, 2011
More informationQuadruple mass spectrometers (transducer type)
Quadruple mass spectrometers that meet the need for sensitive analysis and low outgassing which were specifically designed to be controlled by PCs Quadruple mass spectrometers (transducer type) M-070QA-TDF,
More informationProcedure of Xenon Transfer
Procedure of Xenon Transfer Feng Zhou,MIT CC: Martina Green February 28, 2005 In this write up, we discuss the procedure on how to transfer xenon to a designed gas storage vessel that supplies xenon to
More informationOOC RGA. Ion Pump 400 l/s. 8" ports with baked viton o-ring seals. Welsh rotary roughing pump 650 l/s manual isolation valve.
LASER INTERFEROMETER GRAVITATIONAL WAVE OBSERVATORY - LIGO - CALIFORNIA INSTITUTE OF TECHNOLOGY MASSACHUSETTS INSTITUTE OF TECHNOLOGY Technical Note LIGO-T000126-00- R 11/20/2000 Vacuum pressure at the
More informationPressure & Vacuum Measurement. Series 370. Solutions. Stabil-Ion Vacuum gauge and Controller
w w w. m k s i n s t. c o m Pressure & Vacuum Measurement Solutions Series 370 Stabil-Ion Vacuum gauge and Controller Features & Benefits All-metal, rack-mount controller for Stabil-Ion and Convectron
More informationCharacterizing a Cu/Mn Alloy for Extracting Oxygen from Inert Gas. Streams
Characterizing a Cu/Mn Alloy for Extracting Oxygen from Inert Gas Streams Grace Lenhard Prattsburgh Central School LLE advisors: Walter Shmayda and Matthew Sharpe Laboratory for Laser Energetics University
More informationHigh Va. High Vacuum Pumps. COOLVAC Cryo Pumps COOLPOWER Cold Heads COOLPAK Compressor Units
High Va High Vacuum Pumps COOLVAC Cryo Pumps COOLPOWER Cold Heads COOLPAK Compressor Units 2 Leybold Full Line Catalog 2018 - High Vacuum Pumps leybold Contents High Vacuum Pumps Turbomolecular Pumps TURBOVAC
More informationPerformance of the Liquid Hydrogen Target
Performance of the Liquid Hydrogen Target Presented by Chad Gillis Indiana University at NPDGamma Collaboration Meeting July 2012, Oak Ridge, Tennessee Since upgrading the target for operation at the SNS,
More informationStatus update of Beam pipe. S. Tanaka KEK
Status update of Beam pipe S. Tanaka KEK 1 Gold peel-off problem: Phase 3 Beam pipe Gold peel-off has discovered after the sputtering. Considerable reason of this issue 1, The pipe is an double tube with
More informationDesign and Construction of a GEM-TPC Prototype for R&D Purposes
Design and Construction of a GEM-TPC Prototype for R&D Purposes 2003 IEEE NSS - Satellite Workshop on Micro-Pattern Detectors for Time Projection Chambers Portland, Oregon (USA) 19-25 October, 2003 1)
More informationAIR BEARINGS IN HIGH PRECISION SYSTEMS
AIR BEARINGS IN HIGH PRECISION SYSTEMS I. Crăcăoanu 1 and F. Bremer 1 1 Royal Philips Electronics, Philips Innovation Services, Eindhoven, The Netherlands Abstract: In high precision system applications
More informationDEVICES FOR FIELD DETERMINATION OF WATER VAPOR IN NATURAL GAS Betsy Murphy MNM Enterprises 801 N. Riverside Drive Fort Worth, Texas 76111
INTRODUCTION Water vapor in natural gas has more than a substantial effect on the quality of the gas stream. Without quality measurement of water vapor the gas is basically not saleable. Contracts are
More informationMaterials and Properties IV Outgassing
Outline Materials and Properties IV Outgassing Paolo Chiggiato CERN Accelerator School (CAS) on Vacuum for Particle Accelerators June 18 th 2017 - Gas source and main features. - Order of magnitude. -
More informationCanadian Light Source Inc. Vacuum Component Leak Test Technical Procedure
Canadian Light Source Inc. Vacuum Component Leak Test Technical Procedure CLSI Document 8.7.33.2 Rev. 2 Date: 2006-03-08 Copyright 2006, Canadian Light Source Inc. This document is the property of Canadian
More informationTeacher s Assistant Laboratory Guide
Teacher s Assistant Laboratory Guide Joseph B. Hakanson 1, Warner Meeks 2, and Dr. Joshua L. Rovey 3 Missouri University of Science and Technology, Rolla, Missouri, 65409 These instructions will discuss
More informationDetecting Hydrogen in Helium Streams. Samuel Goodman. Pittsford Mendon High School. Rochester, New York. Advisor: Dr.
1 Detecting Hydrogen in Helium Streams Samuel Goodman Pittsford Mendon High School Rochester, New York Advisor: Dr. Walter Shmayda Laboratory for Laser Energetics University of Rochester Rochester, New
More informationThe Resistive Plate Chamber detectors at the Large Hadron Collider experiments. Danube School, September 8-13, 2014 Novi Sad
The Resistive Plate Chamber detectors at the Large Hadron Collider experiments Roberto Guida PH-DT-DI Danube School, September 8-13, 2014 Novi Sad Ionization chambers Ionizing particles are producing primary
More informationChapter 8: Cryo-sorption pumps
Chapter 8: Cryo-sorption pumps Cryo-sorption pumps offer a clean, quiet, safe, vibration free and inexpensive way to rough pump a vacuum system. They are often used on vacuum systems that are sensitive
More informationbetter measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.
Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis
More informationPRELIMINARY TEST RESULTS ON A CLOSED-LOOP CONTAMINANT REMOVAL SYSTEM FOR PROCESSING OF METALLIC MELTS
PRELIMINARY TEST RESULTS ON A CLOSED-LOOP CONTAMINANT REMOVAL SYSTEM FOR PROCESSING OF METALLIC MELTS Pramod K. Sharma, Gregory S. Hickey, and Kin F. Man Jet Propulsion Laboratory California Institute
More informationLeaks, contamination and closed loop control how RGAs make coating processes more profitable
Leaks, contamination and closed loop control how RGAs make coating processes more profitable Backup: What s an RGA Residual Gas Analyzer An instrument that is measuring the gas composition in a chamber
More informationOutgassing. the hows and whys of measurement. Ron Reid ASTeC Vacuum Science Group STFC Daresbury Laboratory UK
Outgassing the hows and whys of measurement Ron Reid ASTeC Vacuum Science Group STFC Daresbury Laboratory UK Vacuum System Performance Vacuum Equation P = Q S Where P is the base pressure in the system
More informationJT Micro Compressor Test Results
JT Micro Compressor Test Results J.R. Olson, P. Champagne, E. Roth, T. Nast Advanced Technology Center, Lockheed Martin Space Systems Palo Alto, CA 94304, USA ABSTRACT We report the results of operational
More informationUsers days 20&21 october 2011 In situ TEM investigation of helium bubble evolution in SiC at high-temperature under displacing irradiation
In situ TEM investigation of helium bubble evolution in SiC at high-temperature under displacing irradiation Institut P UPR CNRS 3346 SP2MI Téléport 2 Boulevard Marie et Pierre Curie BP 30179 F86962 FUTUROSCOPE
More informationPRad Target. Chris Keith JLab Target Group
PRad Target Chris Keith JLab Target Group Target Overview & Components Target Software Hazard Analysis and Mitigation Target Status, Performance& Remaining Work Installation Schedule Nov. 12, 2015 PRad
More informationELEVATION CORRECTION FACTORS FOR RADON MONITORS*
ELEVATION CORRECTION FACTORS FOR E-PERM@ RADON MONITORS* P. Kotrappa and L. R. Stiefl Abstract-E-PERMm radon monitors are based on the principle of electret ion chambers and are usually calibrated in a
More informationNataliya Sharova, Truls Norby NorECs Norwegian Electro Ceramics AS
Nataliya Sharova, Truls Norby NorECs Norwegian Electro Ceramics AS International Symposium on Diagnostic Tools for Fuel Cells Technologies June 23-24, 2009, Trondheim, Norway Who are we? NorECs is a small
More informationWide-dynamic-range, fast-response CBr 4 doping system for molecular beam epitaxy
Wide-dynamic-range, fast-response doping system for molecular beam epitaxy Yu-Chia Chang a and Yan Zheng Electrical and Computer Engineering, University of California, Santa Barbara, California 9306 John
More informationMETHODS FOR IN SITU QMS CALIBRATION FOR PARTIAL PRESSURE AND COMPOSITIONAL ANALYSIS
METHODS FOR IN SITU QMS CALIBRATION FOR PARTIAL PRESSURE AND COMPOSITIONAL ANALYSIS Robert E. Ellefson REVac Consulting Dayton, OH 45459 USA robert.ellefson@sbcglobal.net ERMP IND12 QMS Workshop Bled,
More informationVacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01
INAOE. Tonantzintla, Mexico. 2010-06-23. June 23 rd, 2010 Vacuum Systems and Cryogenics for Integrated Circuit Fabrication Technology 01 Joel Molina INAOE Microelectronics Group jmolina@inaoep.mx 1 Vacuum
More informationAN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON CRYOCOOLER
P P P International Journal of Scientific Engineering and Applied Science (IJSEAS) - Volume-1, Issue-6, September 2015 AN EXPERIMENTAL INVESTIGATION ON HELIUM LIQUEFACTION USING TWO-STAGE GIFFORD McMAHON
More informationVacuum acceptance tests for particle accelerator equipment
Vacuum acceptance tests for particle accelerator equipment Giuseppe Bregliozzi TE-VSC - CERN Geneva Vacuum for Particle Accelerators Glumslöv, Sweden, 6-16 June, 2017 2 Outline 1. The CERN accelerator
More informationHigh Performance Mass Spectrometers
High Performance Mass Spectrometers For Vacuum and Semiconductor Process Monitoring Detailed product information / introduction MOCVD semiconductor processing Applications: XXCVD/MOCVD XXPECVD XXALD XXSputtering
More informationStudy of the IBF of Double/Triple THGEM
Study of the IBF of Double/Triple THGEM Qian Liu, Carlos, Hongbang LIU, Zhengyang Heng NED 2012, Mianyang 1 Outline PMT/Gas PMT THGEM introduction IBF of DTHGEM study Triple THGEM study Combined analysis
More information1)! DO NOT PROCEED BEYOND THIS MARK
Operating Instructions for X-ray Photoelectron Spectrometer: Physical Electronics Model 555 XPS/AES (John H. Thomas, III, Ph.D., Electron Spectroscopy) Sample Insertion: figure 1. Sample insertion rod
More informationLEO SEM SOP Page 1 of 9 Revision 1.4 LEO 440 SEM SOP. Leica Leo Stereoscan 440i
LEO SEM SOP Page 1 of 9 LEO 440 SEM SOP Gun (Filament) Column Manual Valves Chamber Window Chamber Stage Movement Leica Leo Stereoscan 440i 1. Scope 1.1 This document provides the procedure for operating
More informationDevelopment of a high vacuum sample preparation system for helium mass spectrometer
Journal of Physics: Conference Series Development of a high vacuum sample preparation system for helium mass spectrometer To cite this article: P Kumar et al 2012 J. Phys.: Conf. Ser. 390 012056 View the
More informationBaffles and Traps Cryotrap
Baffles and Traps 362-6 Cryotrap Varian Low-Profile Water-Cooled Baffles combine 100% optical density with high conductance and unusually low overall height. They are especially useful in applications
More informationE SC 412 Nanotechnology: Materials, Infrastructure, and Safety Wook Jun Nam The Pennsylvania State University
E SC 412 Nanotechnology: Materials, Infrastructure, and Safety Wook Jun Nam Unit 2 Infrastructure Lecture 6 More on Vacuum Systems, Part III Unit Outline Infrastructure * What is it? * Why do we need it
More informationPlasma Sources and Feedback Control in Pretreatment Web Coating Applications
Plasma Sources and Feedback Control in Pretreatment Web Coating Applications Joseph Brindley, Benoit Daniel, Victor Bellido-Gonzalez, Dermot Monaghan Gencoa Ltd., Physics Rd, L24 9HP Liverpool, UK (+44)
More informationVertical Parylene Coating System
Technical Specification Vertical Parylene Coating System Overview Our standard Parylene vertical coating system offers users a range of standard feature and options that will meet all needs. The standard
More informationEFFECTS OF OUTGASSING FROM SOME MATERIALS ON GAS CHAMBER AGEING
EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH CERN PPE/94 111 10 June 1994 EFFECTS OF OUTGASSING FROM SOME MATERIALS ON GAS CHAMBER AGEING R. Bouclier, M. Capeáns, C. Garabatos, F. Sauli and K. Silander *
More informationOperating Procedures for Metal Evaporator I
Operating Procedures for Metal Evaporator I Metal Evaporator I is intended as a tool and a training device. Understanding the operation of this equipment should give you a basic knowledge of vacuum and
More informationANL/APS/TB-16 ADVANCED PHOTON SOURCE ACCELERATOR ULTRAHIGH VACUUM GUIDE. Chian Liu and John Noonan
ANL/APS/TB-16 ADVANCED PHOTON SOURCE ACCELERATOR ULTRAHIGH VACUUM GUIDE Chian Liu and John Noonan CONTENTS 1. Ultrahigh Vacuum Overview..... 1 1.1 Vacuum..... 1 1.2 Sources of Residual Gas... 2 1.3 Material
More information2 Switching off ECRIS 3. 4 Acquire Beam Spectrum 4. 6 Vent Instrument Chamber 5. 7 Pump down Chamber 5. 8 Baking out Chamber 5.
Contents 1 Starting the ECR ion source (ECRIS) 2 2 Switching off ECRIS 3 3 Starting Mefisto Beam Analyzer 4 4 Acquire Beam Spectrum 4 5 Open Valve ECRIS/Chamber (Gate valve) 4 6 Vent Instrument Chamber
More informationA high-sensitivity large volume cryogenic detector for radon in gas
DOI: 10.1007/s10967-008-0730-7 Journal of Radioanalytical and Nuclear Chemistry, Vol. 277, No.1 (2008) 199 205 A high-sensitivity large volume cryogenic detector for radon in gas M. Wojcik, 1 * G. Zuzel
More informationDynamic and static deuterium inventory in ASDEX Upgrade with tungsten first wall
1 IAEA-CN-165 / EX / P4-3 Dynamic and static deuterium inventory in ASDEX Upgrade with tungsten first wall V. Rohde, M. Mayer, V. Mertens, R. Neu, K. Sugiyama and the ASDEX Upgrade Team Max-Planck-Institut
More informationLow-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump
8 th Harsh Environment Mass Spectrometry Wokshop Low-Power Atmospheric Gas Sampling System Based on ART MS Sensor and NEG-Ion Pump Sept 22, 2011 Gerardo A. Brucker and G. Jeffery Rathbone Granville-Phillips
More information