Water Thiefs APPLIANCES APPLIANCES WATER THIEFS

Size: px
Start display at page:

Download "Water Thiefs APPLIANCES APPLIANCES WATER THIEFS"

Transcription

1 WATER THIEFS Water Thiefs A Water Thief allows the fire professional to extend attack lines from a main supply line. Elkhart s selection of Water Thief options includes Storz connectors which, when combined with our unique free swiveling inlets and/or outlets, help prevent accidental uncoupling of larger diameter hose for increased safety. 4-1

2 WATER THIEFS INLET Storz** (Swivel) FLOW THROUGH OUTLETS Twist-Lock Gear Driven Quarter Turn Storz** 2.5"F* 4.0" 5.0" 2.5"M 4.0" 5.0" 1.5"M (X2) THIEF OUTLETS Self-Locking Quarter Turn 2.5"M (X2) Gated 2.5"M (X2) RELIEF VALVE Brass Elk-O-Lite s s BG-104A* 1 s s BG s o s o Satin Brass MATERIAL /TRIM Chrome Hard Anodized DIMENSIONS Length (Inches) Weight (Lbs.) MODEL FIGURE s o s o KEY s = standard o = option * Optional pressure gauges available ** Free swivel FIGURE 1 BG-104 / BG-104A Flow through outlet (2.5") has acetal ball with adjustable neoprene seat and metal twist-lock handles Thief outlets (1.5") have self-adjusting UHMWPE seats and flexible urethane handles Leather carrying handles OPTIONS HANDLES BG-104A comes standard with: 4-2 Optional pressure gauge Fig. 1 FIGURE Flow through Storz outlet has a gear actuated quarter turn 4" ball valve with aluminum ball and UHMWPE seat Thief outlets are 2.5" full flow, self-locking, Hydro-Loc, quarter turn, acetal ball valves with neoprene seats Adjustable relief valve ( psi) LONG (ELK-O-LITE ) BG-104A options include: SHORT (ELK-O-LITE ) Fig. 2 FIGURE Flow through Storz outlet is a gear actuated quarter turn 4" ball valve with aluminum ball and UHMWPE seat Thief outlets are 2.5" gate valved outlets Adjustable relief valve ( psi) MOLDED URETHANE THREADS All fireground connections are T-12 for optional base threads. Fig. 3

3 GATED MANIFOLDS Gated Manifolds Gated manifolds allow fire professionals to extend attack lines when pre-connects do not reach. All of Elkhart s gated manifolds feature: Free swiveling, locking Storz connectors to prevent accidental uncoupling of larger diameter hose for increased safety Adjustable relief valve ( psi) with stainless steel mechanism and urethane seat for safe LDH operations Easy operation even at high flows Working pressure up to 200 psi (13.79 bar) Minimal friction loss Modular design Elk-O-Lite construction with red urethane trim Easy field service 4-3

4 GATED MANIFOLDS LDH INLET SIZE Storz LDH OUTLET SIZE 4.0" 5.0" 4.0" 5.0" " M OUTLETS s o o s o o o s o s s o o s o o o s o s KEY s = standard o = option Storz Quantity Valve Type Ball Gated BLEEDER VALVE 0.75" DIMENSIONS Length (Inches) Weight (Lbs.) MODEL FIGURE FIGURE 1 FIGURE / 9713 Full-flow, self-locking Hydro-Loc, quarter turn, 2.5" acetal ball valves with neoprene seats 9812 / 9813 X-86A gate valved outlets (2.5") Fig. 1 Fig. 2 FIGURE 3 FIGURE Functions as a portable hydrant Single Storz outlet has a gear actuated quarter turn 4" ball valve with acetal ball and neoprene seat Four outlets are 2.5" full flow, self-locking, Hydro-Loc, quarter turn, acetal ball valves with neoprene seats Liquid-filled pressure gauge (0-300) Fig Functions as a portable hydrant Single Storz outlet has a gear actuated quarter turn 4" ball valve with acetal ball and neoprene seat Four X-86A gate valved outlets (2.5") Liquid-filled pressure gauge (0-300) Fig. 4 OPTIONS THREADS All fireground connections are unless otherwise specified. See index T-12 for optional base threads.

5 PLAIN & CLAPPERED SIAMESE Plain & Clappered Siamese Used to combine several hoselines into one usually in situations where seconds count a Siamese must be both reliable and intuitive to use. Clappers allow additional lines to be added without interrupting flow. As with all Elkhart products, years of dependable service are to be expected from an Elkhart Siamese. While all the Siamese are finished in red urethane enamel, the Elk-O-Lite versions feature hard anodized trim and the brass versions offer satin brass trim. 4-5

6 PLAIN & CLAPPERED SIAMESE INLET SIZE AVAILABLE OUTLET SIZE TYPE Female* 1.5" (X2) 2.5" (X2) 2.5" (X3) Male 1.5" 2.5" 3.0" 4.0" 4.0" 5.0" KEY s = standard o = option * Swivel ** Free swivel Storz** Plain Clappered Single Swinging Independent Spring Loaded DRAIN VALVE.75" ADJUSTABLE RELIEF VALVE MATERIAL Brass Elk-O-Lite DIMENSIONS A 1 s A 2 s Length (Inches) s s s s Weight (Lbs.) MODEL FIGURE FIGURE 1 FIGURE /2A Apparatus mountable 4/4A Apparatus mountable Leather carrying handle Fig. 1 Fig. 2 FIGURE 3 FIGURE Adjustable relief valve ( psi) Locking Storz 9703 Adjustable relief valve ( psi) Locking Storz Fig. 3 Fig. 4 OPTIONS THREADS All fireground connections are unless otherwise specified. See index T-12 for optional base threads. ADDITIONAL INFORMATION Chrome trim available on some brass models. Please inquire with our sales staff. More Siamese options available. See page 4-7.

7 VALVED SIAMESE Valved Siamese Used to combine several hoselines into one usually at the fire scene a Siamese must be both reliable and intuitive to use. All the Siamese are finished in red urethane enamel; the Elk-O-Lite versions feature hard anodized trim and the brass versions offer chrome trim. As with all Elkhart products, years of dependable service are to be expected from an Elkhart Siamese. 4-7 Valve type determines available handle style from 3 options

8 VALVED SIAMESE INLETS 2.5" F (X2) 2.5" F (X3) AVAILABLE OUTLETS Type Female (Swivel) Male (Rigid) Storz (Free Swivel) Female (Swivel) Male (Rigid) Storz (Free Swivel) Size 2.5" 3" 3.5" 4" 4.5" 5" 6" 2.5" 3" 3.5" 4" 4.5" 4" 5" 2.5" 3" 3.5" 4" 4.5" 5" 6" 2.5" 3" 3.5" 4" 4.5" 4" 5" 1/4 Turn Ball Valve TYPE X-86A Gate Valve HANDLE STYLE Crank Self-Locking Twist-Lock Bleeder Valve.75" VALVES Adjustable Relief Valve MATERIAL Brass Elk-O-Lite Length (Inches) DIMENSIONS o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98 1 o B-98A 1 s o s o B-98A 1 s o s o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99 2 o B-99A 2 o B-99 2 s o s o B-99A 2 s o s Weight (Lbs.) MODEL FIGURE 4-8 KEY s = standard o = option

9 VALVED SIAMESE FIGURE 1 FIGURE 3 B-98/B-98A Apparatus mountable Built-in strainer Adjustable neoprene seats 9722 Full, flow Hydro-Loc valves Adjustable relief valve ( psi) FIGURE 2 B-99/B-99A Apparatus mountable Built-in strainer Adjustable neoprene seats Fig. 1 Fig. 2 FIGURE Full, flow Hydro-Loc valves Adjustable relief valve ( psi) Fig. 3 Fig FIGURE Adjustable relief valve ( psi) Fig. 5 OPTIONS ADDITIONAL INFORMATION THREADS All fireground connections are unless otherwise specified. See index T-12 for optional base threads. All twist-locks feature metal knurled knobs. More Siamese options available. See page 4-5.

10 WYES Wyes Used to divide a single flow, usually at a fireground scene, wyes must be both reliable and intuitive to use. Elkhart offers several customizable handle options. All Elkhart wyes give years of dependable service. When necessary, they are easy to field service and re-buildable for continued long-term use. Both 2-way and 3-way wye options available Swivel inlets Customizable handle options All ball valve wyes feature acetal balls with self-adjusting UHMWPE seats.

11 WYES 4-11 INLET SIZE 1.0 (F) 1.5" (F) 2.5" (F) 3.0" (F) 3.5" (F) 4.0" (F) 4.5" (F) 5.0" STORZ 5.0" (F) 6.0" (F) 0.75" (x2) OUTLET SIZE (MALE) TYPE HANDLE STYLE 1" 1.5" 2.5" (x2) (x2) (x2) (x3) Plain Ball Valved Knob Short Elk-O-Lite Long Elk-O-Lite Molded Urethane Positive Twist Lock MATERIAL/ TRIM o o s o B-100-SA 3 o o s o B-100-SA 3 o s B-100-L 3 o o s o B-100-LA A o o s o B-100-A* 3 o s B A s B-97A 2 s B A s B-95A 1 s B A 4 s B-97A 2 s B-97 2 s B-95A 1 s B A s B-97A 2 s B-97 2 s B-95A 1 s B A s B-97A 2 s B-97 2 s B-95A 1 s B-95 1 s B-97A 1 s B-95A 1 s B-97A 2 s B-97 2 s B-95A 1 s B-95 1 s B-97A 2 s B-97 2 s B-95A 1 s B-95 1 Brass / Chrome Elk-O-Lite / Hard Anodized DIMENSIONS Length (Inches) Weight (Lbs.) MODEL FIGURE KEY s = standard o = option * Optional pressure gauge available

12 WYES FIGURE 1 FIGURE 2 B95/B95A (3-WAY) POSITIVE TWIST LOCK Fig. 1 B97/B97A (2-WAY) POSITIVE TWIST LOCK Fig. 2 FIGURE 3 FIGURE B-100/B-100A Fig. 3 1/1A Fig. 4 Figures depict general product types only and are not intended to be inclusive of all product features. OPTIONS HANDLES PRESSURE GAUGE THREADS KNOB SHORT (ELK-O-LITE ) LONG (ELK-O-LITE ) Not all handles available on all models. All twist-locks feature metal knurled knobs. MOLDED URETHANE POSITIVE TWIST LOCK All fireground connections are unless otherwise specified. See index T-12 for optional base threads. PSI RATING While all Elkhart wyes are rated to at least 200 psi (13.79 bar), the products specified below are rated to 300 psi (20.69 bar): B-100-A (2.5" F inlet) B-100-LA (1.5" F inlet) B-100-SA (1.0" F or 1.5" F inlet)

13 PISTON INTAKE Piston Intake Elkhart offers piston intake valves in your choice of materials. All piston valves include a variety of features to make your job easier: folding hand-wheel spinner, durable urethane seat, 4 1 /2 " waterway, 3 /4 " bleeder valve, adjustable relief/dump valve (75 to 250 psi) and a red urethane enamel finish. 4-13

14 PISTON INTAKE TRUCK CONNECTION MATERIAL/ HOSE CONNECTION (Inches) (Inches) TRIM DIMENSIONS Elk-O Female** Male Storz** Female* Brass -Lite Length Weight 3 1 / / / / / o o o o o o o o o o o o o s o o o o o o o o o o o o o s KEY s = standard o = option * Swivel ** Free swivel Chromeplated Hard Anodized (Inches) (Lbs.) MODEL FIGURE Figure 1 Figure Fig. 1 Fig. 2 ADDITIONAL INFORMATION While many piston intake valves have the common issue of corrosion, resulting in minor leaks to complete failure depending on service conditions and water supply; Elkhart s 9786 piston intake valve offers a solution. The replaceable anode electrolytically decomposes, while inhibiting the metal breakdown of the piston intake valve. THREADS All fireground connections are unless otherwise specified. See index T-12 for optional base threads.

MANUAL: Jumbo Siamese and Jumbo Wye

MANUAL: Jumbo Siamese and Jumbo Wye TASK FORCE TIPS FIRE FIGHTING EQUIPMENT MANUAL: Jumbo Siamese and Jumbo Wye INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE Read instruction manual before use. Operation of this device without understanding

More information

MANUAL: Jumbo Gate Valve

MANUAL: Jumbo Gate Valve MANUAL: Jumbo Gate Valve INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE Read instruction manual before use. Operation of this device without understanding the manual and receiving proper training is a

More information

INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES

INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 5 TOPIC: SUPPLY LINES AND SALVAGE LEVEL OF INSTRUCTION: TIME REQUIRED: THREE HOURS INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED

More information

Flow Material Length. Weight GPM LPM. Style 3095

Flow Material Length. Weight GPM LPM. Style 3095 Akron Municipal Eductors feature a large, easy to read, and removable metering dial with infinite settings between 0% and 6%. Detents at 1 4, 1 2, 1, 3 and 6%. The Eductors are rated to flow at 200 psi

More information

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual 10-12 Steel Pipe Squeezer Sch. 40 & Sch. 80 Operations Manual 1.0 Introduction This manual is issued as a basic operation manual covering the Regent Model 7989T, Pipe Squeezer and Pump as manufactured

More information

Description Advanced Features Typical Applications

Description Advanced Features Typical Applications Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied

More information

MANUAL: LDH GATED WYE

MANUAL: LDH GATED WYE MANUAL: LDH GATED WYE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE NOTICE Read Instruction Manual before use. Operation of this device without understanding the manual and receiving proper training

More information

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA

INSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA TOPIC: RELAY PUMPING OPERATIONS LEVEL OF INSTRUCTION: TIME REQUIRED: ONE HOUR INSTRUCTOR GUIDE MATERIALS: APPROPRIATE AUDIO VISUAL SUPPORT REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST

More information

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)

Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar) Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar) The quickest and most economical way to perform pneumatic field pressure calibrations on pressure transmitters, switches

More information

Operating Instructions Model and Hydrostatic Test Pump

Operating Instructions Model and Hydrostatic Test Pump Operating Instructions Model 39300 and 39301 Hydrostatic Test Pump Dimension Weight Pump Style Capacity Pressure Motor Lubrication Control Gauge Inlet Connection Outlet Connection Discharge Hose Hose Ends

More information

Panel-mounted valves Series T, Ø 22.5 mm

Panel-mounted valves Series T, Ø 22.5 mm Series T, Basic valve 3/2-way, M5 (10/32 UNF) M 5 and G 1/8 2.122 Basic valve 3/2-way, M5 (10/32 UNF) M 5 and G 1/8 2.122 Push button 18-T-23-011 2.126 Mushroom 18-T-23-012 2.126 2-position switch 18-T-23-013

More information

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1

PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1 PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1 SUPPLEMENT 101 101. HIGH PRESSURE FIRE HYDRANT SYSTEM The High Pressure

More information

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM HYDRA ASSIST VALVE

LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM HYDRA ASSIST VALVE LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM HYDRA ASSIST VALVE 45 46 LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM INDIVIDUAL SKILLS HYDRA-ASSIST The Hydra-Assist valve is

More information

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8 and 1/4 PTF Port Sizes. Air line equipment. Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass

More information

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New > Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,

More information

Operating Instructions Model and Hydrostatic Test Pump

Operating Instructions Model and Hydrostatic Test Pump Operating Instructions Model 29200 and 2920 Hydrostatic Test Pump Dimension Weight Pump Pressure for 29200 Pump Pressure for 2920 Gauge for 29200 Gauge for 2920 Inlet Connection Outlet Connection Hose

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

Instruction Manual Updated 7/26/2011 Ver. 2.2

Instruction Manual Updated 7/26/2011 Ver. 2.2 4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:

More information

MANUAL: LDH GATED WYE

MANUAL: LDH GATED WYE MANUAL: LDH GATED WYE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE NOTICE Read Instruction Manual before use. Operation of this device without understanding the manual and receiving proper training

More information

Apparatus Operator Refresher Training Program

Apparatus Operator Refresher Training Program Division of Training In-Service Training Program Apparatus Operator Refresher Training Program 1 Single Engine / Single Line Operation Refresher Evolution #1 Objective: Charging single handlines at correct

More information

TurboDraft Fire Eductor

TurboDraft Fire Eductor TurboDraft Fire Eductor Operating Manual Introduction The TurboDraft is designed to be used for rural water supply operations. Many of us take for granted that there is a fire hydrant on every corner.

More information

Choosing the right miniature instrument and control valve is a snap

Choosing the right miniature instrument and control valve is a snap Choosing the right miniature instrument and control valve is a snap INVALCO Micro Valve The Micro Valve is a unique miniature valve offering versatility and rugged construction. Since its introduction

More information

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw. Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on

More information

2.0 INSTALLATION & SERVICE

2.0 INSTALLATION & SERVICE Installation, Operation, and Maintenance Instructions MODEL 5600 / 5600R January 2005 CONTENTS 1.0 GENERAL 1.1 5600 Model Number Information -----------------------------------------------------------------------

More information

Data Sheet Issue A

Data Sheet Issue A Features 1. Differential-type valve, lightweight, dependable construction. 2. Low Air Pressurized System, 10 psi -to- 26 psi (0,7 bar -to- 1,8 bar). 3. Reset externally.cover removal is not required. 4.

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

HANNAY REELS. Rescue Reels

HANNAY REELS. Rescue Reels Rescue Reels HANNAY REELS For use for: Haz-mat situations Vehicular extrications At-the-scene emergencies reathing and utility air applications H-9406-R Revision 5 INTRODUTION Hannay s Triad Rescue Reels

More information

Pressure reducing valves Index

Pressure reducing valves Index Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel

More information

Please Contact Do It American for Pricing

Please Contact Do It American for Pricing J Product List Please Contact Do It American for Pricing BK-22-01 27.2 Cu. Ft. Portable Bypass System Box and Regulation only (7 IWC) BK-22-02 27.2 Cu. Ft. Portable Bypass System Box, Regulation, and Cylinder

More information

12 Impeller Replacement

12 Impeller Replacement 144 Impeller Replacement INTRODUCTION Jabsco The Original Impeller Jabsco Flexible Impellers can be fitted to most makes and models of bronze flexible impeller engine cooling, bilge, transfer and general

More information

Head to Head Demo Comparison Sheet

Head to Head Demo Comparison Sheet Head to Head Demo Comparison Sheet Task Force Tips Crossfire Portable/Deck Mount Monitor The purpose of this document is to encourage you to compare TFT products head to head, apples to apples, with like

More information

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data

ALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data ir line equipment Miniature eneral Purpose egulators 7, (non-repairable) 7 Full flow gauge ports Snap action knob locks pressure setting when pushed in Standard relieving models allow reduction of outlet

More information

HIGH FLOW HIGH PRESSURE PUMP type BMS

HIGH FLOW HIGH PRESSURE PUMP type BMS When you have to test objects on different locations within your workshop, the mobile pump system BMS gives you the possibility to test adequately on different sites. Through its wheels (or forklift pockets)

More information

Specialty Products. Specialty Products Index

Specialty Products. Specialty Products Index Specialty Products MAXIMATOR has been designing and manufacturing specialty products to serve the high pressure market for over thirty years and has a worldwide reputation for quality and reliability.

More information

LQ Series Connectors. What is the LQ2?

LQ Series Connectors. What is the LQ2? LQ Series Connectors LQ2 Connections Frequently Asked Questions What is the LQ2? The LQ2 Series connectors are the latest addition to CPC s liquid cooling of electronics (LCoE) Series. For liquid cooling

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company

SABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN

More information

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7 EXEL North America, Inc. EXEL Industrial Canada, Inc. 1310 Washington St 931 Progress Ave., #7 West Chicago, IL 60185 Scarborough ONT, M1G 3V5 Ph : (800) 573 5554 Ph : (800) 450 0655 Fx : (800) 664 1511

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

Data Sheet Issue A

Data Sheet Issue A Features 1. Differential latching clappertype, lighweight, dependable construction. 2. Low Air Pressurized System, 8 psi -to- 26 psi (0,6 bar to- 1,8 bar) 3. Reset externally. Cover removal is not required.

More information

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany

Ball valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany Ball valve HKSF-W100 RMA Kehl GmbH & Co. KG Oststrasse 17 D-77694 Kehl / Germany info@rma-kehl.de www.rma-armaturen.de 1 Design Features: RMA-ball valves type HKSF-W are fully welded and completely maintenance-free

More information

Advantage 4000 Abrasi-Blast Respirator

Advantage 4000 Abrasi-Blast Respirator Advantage 4000 Abrasi-Blast Respirator Features Constant Flow Air-Line Respirator and Constant Flow Duo-Flo Respirator options Choice of shoulder length or waist length hoods to meet various blasting applications

More information

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS

STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS The Akron Style 3414/3416 & 3421/3423 Apollo Monitor is designed to provide efficient trouble-free operation

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 46453 and 464530 Hydrostatic Test Pumps 46453 DIMENSIONS: 27 (67.5cm) L x 22 (55cm) W x 34 (85cm) H WEIGHT: 160 lbs. 73 kg PUMP: Twin piston: Positive displacement type Inlet

More information

MANUAL: 5-WAY MANIFOLD

MANUAL: 5-WAY MANIFOLD MANUAL: 5-WAY MANIFOLD INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE NOTICE NOTICE Read Instruction Manual before use. Operation of this manifold without understanding the manual and receiving proper

More information

APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, ANDMAINTENANCE INSTRUCTIONS

APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, ANDMAINTENANCE INSTRUCTIONS APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, ANDMAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation and maintenance of the

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

F l o w c o n T R o l v a l v E S

F l o w c o n T R o l v a l v E S Composite Right Angle Flow Control Valves Series TMCU-TMVU-TMCO- BSP/METRIC Meter In, Meter Out, Needle Orifice G1/8, G1/, G3/8, G1/2 Banjo flow controllers Nominal diameters Ø 2-3.8-5.8-8 The Meter In,

More information

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.

Model DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction. Bulletin 335 Model DDX-LP Dry Pipe Valve System 8 (200mm) Bulletin 335 Features 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Differential latching clapper-type, lighweight, dependable construction. Low Air Pressurized

More information

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.

More information

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection February 9, 1998 Foam 201a 1. DESCRIPTION A Deluge Bladder Tank Foam/Water System is a standard deluge system capable of discharging a foam/water solution automatically through open sprinklers, spray nozzles,

More information

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes

Features. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes Bulletin 357 Rev. E Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes Bulletin 357 Rev. E Features 1. 2. 3. 4. 5. 6. 7. 8. 9. Differential-type valve, lightweight, dependable construction.

More information

First Stage Regulators

First Stage Regulators DOMESTIC First stage regulators are typically used to reduce tank pressure to an intermediate pressure, usually 5 to 10 PSI for further pressure reduction by a second stage regulator located closer to

More information

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009 April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

AIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES

AIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES Series AIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES Standard Air Chucks 374 Flow-Thru Air Chucks 375 Standard Pencil Tire Gauges 376 Dual Foot Tire Gauges 377 Dial Tire Gauges 378 Digital Tire Gauges 379

More information

Direct Operated Precision Regulator Modular Style. Standard Specifications

Direct Operated Precision Regulator Modular Style. Standard Specifications 1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com

More information

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013

TECHNICAL DATA. Trimpac 251a. Spetember 16, 2013 Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release

More information

SIMPLAIR PIPING TOOL. JXT Company

SIMPLAIR PIPING TOOL. JXT Company SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.

More information

TITAN Oxygen Regulators

TITAN Oxygen Regulators EMS OXYGEN REGULATORS TITAN Oxygen Regulators EMS TITAN SERIES OXYGEN EMS AND FIRE SERVICE APPLICATIONS CLICK-STYLE REGULATOR Whether its EMS, ambulance, fire rescue or tactical medical use, Titan Oxygen

More information

shutoff valves 900 Series psig Manual Shutoff Valves

shutoff valves 900 Series psig Manual Shutoff Valves 0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on

More information

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE February 9, 1998 Foam 101a A BLADDER TANK WITH 1. DESCRIPTION A Wet Pipe Bladder Tank Foam/Water System is a standard wet pipe automatic sprinkler system capable of discharging a foam/water solution automatically

More information

Storage Systems and Accessories

Storage Systems and Accessories Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single

More information

North American Orifice Metering System

North American Orifice Metering System Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

Hose & Reel. Rescue Hose Reels. Haz-mat Situations Vehicular Extrications. At-the-scene Emergencies Breathing and Utility Air Applications

Hose & Reel. Rescue Hose Reels. Haz-mat Situations Vehicular Extrications. At-the-scene Emergencies Breathing and Utility Air Applications Hose & Reel P R O D U C T S Rescue Hose Reels Haz-mat Situations Vehicular Extrications At-the-scene Emergencies Breathing and Utility Air Applications 2 Note to the designers & engineers. Rescue Reels

More information

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Description Supply pressure Pressure range Connection Device Page max. bar bar thread Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4

More information

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified TYPE G-4 DESCRIPTION FIG 2042 - Bronze FIG 2043 - Bronze

More information

1200 Series Pressure Regulators

1200 Series Pressure Regulators SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of

More information

AUTOMATIC HOSE TEST UNIT, TYPE SPU

AUTOMATIC HOSE TEST UNIT, TYPE SPU VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE

More information

HP/UHP Spring-Loaded Regulator

HP/UHP Spring-Loaded Regulator Description HP (High Purity) and UHP (Ultra High Purity) products are for service where the product must be kept free of contamination. The design is kept simple to minimise dead areas where contaminants

More information

Nozzles and portable monitors

Nozzles and portable monitors Nozzles and portable monitors Rosenbauer Nozzles and portable monitors Nozzles and portable monitors. EN maximum extinguishing effect. The Rosenbauer nozzle enables the manual 4-stage adjustment of the

More information

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax

61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax 6R STANDARD REGULATOR COMPACT REGULATOR 496 Phone 7.63.888 Fax 7.63.690 6R AND 496 REGULATORS General Information The Model 6R and 496 Compact Regulator (CR) are designed to deliver reliable and safe regulation

More information

Bladder Tank Installation & System Design Information

Bladder Tank Installation & System Design Information Bladder Tank Installation & System Design Information The Chemguard Bladder Tank is one component in a balanced pressure foam proportioning fire protection system. It requires no external power other than

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Standard Specifications

Standard Specifications NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max.

More information

Speed control assembly model A-1

Speed control assembly model A-1 Pressure Regulation 533a 1. DESCRIPTION The Viking Speed Control Assembly provides adjustment of the opening speed of Viking Deluge Valves, and adjustment of both the opening and closing speed of Viking

More information

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm s s RS Differential NB 9.5mm RVA In-line Differential NB 6 to 19mm RV Direct Acting NB up to 9mm LPR Low Pressure Differential NB 8mm We design, machine, build and test all our products on one site in

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

MEDICAL CYLINDER VALVES

MEDICAL CYLINDER VALVES MEDICAL CYLINDER VALVES 3 1 Medical integrated valve for oxygen air and medical mixture 1.1 ALIONE 1.2 ALPINOX-valve 1.3 ALPINOX-valve compact 2 Cylinder valve with RPV for oxygen and medical gases -

More information

TECHNICAL DATA. Trimpac 244a. September 16, 2013

TECHNICAL DATA. Trimpac 244a. September 16, 2013 September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally

More information

Pressure Equalising Valves Model , for Differential Pressure Gauges

Pressure Equalising Valves Model , for Differential Pressure Gauges Accessories Pressure Equalising Valves Model 910.25, for Differential Pressure Gauges WIKA Data Sheet AC 09.11 Applications T Isolating, pressure equalising as well as purging and air bleeding valves to

More information

A BRIEF TUTORIAL ON GAS HANDLING EQUIPMENT

A BRIEF TUTORIAL ON GAS HANDLING EQUIPMENT TABLE OF CONTENTS BACK PRESSURE REGULATORS...26 CGA CONNECTION DRAWINGS...102 CGA CYLINDER CONNECTIONS AND GASKETS...98 CHANGEOVER MANIFOLDS...60-63,65 CHECK VALVES...70 CONVERSION TABLES...103 CUSTOM

More information

BLAST-IT-ALL. TOLL FREE: (800)

BLAST-IT-ALL. TOLL FREE: (800) BLAST-IT-ALL TOLL FREE: (800) 535-2612 sales@blast-it-all.com www.blast-it-all.com BLAST-IT-ALL TOLL FREE: (800) 535-2612 sales@blast-it-all.com www.blast-it-all.com MICROVALVE The MicroValve gives you

More information

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 0 PROJECT : QUANTITY : 0 LOCATION : SERVICE : FOAM SYSTEM 0 05 CODE & STANDARDS

More information

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912

Water. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912 Water VAG DUOJET Automatic Air Valve Single-chamber type Product characteristics and benefits Resilient seated With flange end acc. to EN 1092-2 Single chamber air valve in compact design Very high discharge

More information

TONS! powerteam.com HEAVY LIFT CYLINDERS

TONS! powerteam.com HEAVY LIFT CYLINDERS NEW DESIGNS TONS! powerteam.com HEAVY LIFT CYLINDERS THE Precise MOST Positioning COMPREHENSIVE & ControlRANGE OF HIGH in a Responsive PRESSURE Package HEAVY LIFT CYLINDERS R_G SINGLE & DOUBLE ACTING,

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 36454 and 364540 Hydrostatic Test Pumps 36454 DIMENSIONS: 24 (61cm) L x 19 (48cm) W x 19.5 (50cm) H WEIGHT: 135 lbs 61.5 kg PUMP: Twin piston: Positive displacement type Inlet

More information

S300 Series. Valve Link. Features. Fisher Controls

S300 Series. Valve Link. Features. Fisher Controls S0 Series Self-Operated Type VL FIELDVUE Regulators Valve Link Fisher Controls May 198 Bulletin 71.1:S0 The S0 Series self-operated, spring-loaded regulators are used for pressure-reducing control in a

More information

B84G - Excelon Plus Modular System General purpose filter/regulator

B84G - Excelon Plus Modular System General purpose filter/regulator > Port size: 3/8" to 3/4" (PTF/ISO G) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant

More information

Operating Manual. Models MP-23ENBC, MP-23LPANB, MP-23EHNBC, MP-2300HNB

Operating Manual. Models MP-23ENBC, MP-23LPANB, MP-23EHNBC, MP-2300HNB Models MP-23ENBC, MP-23LPANB, MP-23EHNBC, MP-2300HNB Manual No. AIRCRT22 (Rev 1 July 2007) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757)

More information

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm

SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation Size: inch / mm Every Ross Valve shall be hydrostatically tested for body integrity and tight seating

More information

Evaluating 2-1/2 Direct Fill Lines Colton, New York

Evaluating 2-1/2 Direct Fill Lines Colton, New York www.gotbigwater.com Tanker Fill Tests Evaluating 2-1/2 Direct Fill Lines Colton, New York August 24, 2008 Overview On August 23 rd and 24 th, 2008, the Colton (NY) Fire District hosted a Rural Water Supply

More information

REGULATORS FOR SPECIFIC APPLICATIONS

REGULATORS FOR SPECIFIC APPLICATIONS SINGLE-STAGE REGULATORS FOR NITROUS OXIDE AND CARBON DIOXIDE (MODELS SG9011, SG9012, SG9014) Nitrous Oxide and Carbon Dioxide frequently cause ordinary regulators to freeze up. Models SG9011, SG9012 and

More information

Modular Type Regulators

Modular Type Regulators Modular Type Regulators Series AR AC Regulator Series AR Port size Options AFARAL, 1/4 Bracket AFAR AWAL AR4-A, 1/2 Round type pressure gauge With set nut (for panel mount) AFAFMAR P.45 to 5 AR4-6-A ot

More information

Pneumatic Powered - Plunger Pumps

Pneumatic Powered - Plunger Pumps Models 42/62/82 D Series P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pumps Suggested Installation & Operating Instructions

More information

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB

AIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB Manual #: MM-AD001 12/5/11 Rev. A Page 1 of 8 PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB Manual #: MM-AD001 12/5/11 Rev. A Page 2 of

More information

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual WHEATLEY SERIES 500 SWING CHECK VALVE STANDARD INTEGRAL SEAT & OPTIONAL REMOVABLE SEAT 2" FP - 6" FP 150# - 1500# 8" FP - 12" FP 150# - 900# API 6D and B16.34 2" FP - 4" FP 5000# DRILLING PRODUCTION VALVE

More information

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO

Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Swivel Design : Meter-Out, Meter-In and Needle Orifice Tube Diameter OD: 1/8, 5/2, 1/4, 5/16, /8

More information