Water Thiefs APPLIANCES APPLIANCES WATER THIEFS
|
|
- Jodie Dawson
- 5 years ago
- Views:
Transcription
1 WATER THIEFS Water Thiefs A Water Thief allows the fire professional to extend attack lines from a main supply line. Elkhart s selection of Water Thief options includes Storz connectors which, when combined with our unique free swiveling inlets and/or outlets, help prevent accidental uncoupling of larger diameter hose for increased safety. 4-1
2 WATER THIEFS INLET Storz** (Swivel) FLOW THROUGH OUTLETS Twist-Lock Gear Driven Quarter Turn Storz** 2.5"F* 4.0" 5.0" 2.5"M 4.0" 5.0" 1.5"M (X2) THIEF OUTLETS Self-Locking Quarter Turn 2.5"M (X2) Gated 2.5"M (X2) RELIEF VALVE Brass Elk-O-Lite s s BG-104A* 1 s s BG s o s o Satin Brass MATERIAL /TRIM Chrome Hard Anodized DIMENSIONS Length (Inches) Weight (Lbs.) MODEL FIGURE s o s o KEY s = standard o = option * Optional pressure gauges available ** Free swivel FIGURE 1 BG-104 / BG-104A Flow through outlet (2.5") has acetal ball with adjustable neoprene seat and metal twist-lock handles Thief outlets (1.5") have self-adjusting UHMWPE seats and flexible urethane handles Leather carrying handles OPTIONS HANDLES BG-104A comes standard with: 4-2 Optional pressure gauge Fig. 1 FIGURE Flow through Storz outlet has a gear actuated quarter turn 4" ball valve with aluminum ball and UHMWPE seat Thief outlets are 2.5" full flow, self-locking, Hydro-Loc, quarter turn, acetal ball valves with neoprene seats Adjustable relief valve ( psi) LONG (ELK-O-LITE ) BG-104A options include: SHORT (ELK-O-LITE ) Fig. 2 FIGURE Flow through Storz outlet is a gear actuated quarter turn 4" ball valve with aluminum ball and UHMWPE seat Thief outlets are 2.5" gate valved outlets Adjustable relief valve ( psi) MOLDED URETHANE THREADS All fireground connections are T-12 for optional base threads. Fig. 3
3 GATED MANIFOLDS Gated Manifolds Gated manifolds allow fire professionals to extend attack lines when pre-connects do not reach. All of Elkhart s gated manifolds feature: Free swiveling, locking Storz connectors to prevent accidental uncoupling of larger diameter hose for increased safety Adjustable relief valve ( psi) with stainless steel mechanism and urethane seat for safe LDH operations Easy operation even at high flows Working pressure up to 200 psi (13.79 bar) Minimal friction loss Modular design Elk-O-Lite construction with red urethane trim Easy field service 4-3
4 GATED MANIFOLDS LDH INLET SIZE Storz LDH OUTLET SIZE 4.0" 5.0" 4.0" 5.0" " M OUTLETS s o o s o o o s o s s o o s o o o s o s KEY s = standard o = option Storz Quantity Valve Type Ball Gated BLEEDER VALVE 0.75" DIMENSIONS Length (Inches) Weight (Lbs.) MODEL FIGURE FIGURE 1 FIGURE / 9713 Full-flow, self-locking Hydro-Loc, quarter turn, 2.5" acetal ball valves with neoprene seats 9812 / 9813 X-86A gate valved outlets (2.5") Fig. 1 Fig. 2 FIGURE 3 FIGURE Functions as a portable hydrant Single Storz outlet has a gear actuated quarter turn 4" ball valve with acetal ball and neoprene seat Four outlets are 2.5" full flow, self-locking, Hydro-Loc, quarter turn, acetal ball valves with neoprene seats Liquid-filled pressure gauge (0-300) Fig Functions as a portable hydrant Single Storz outlet has a gear actuated quarter turn 4" ball valve with acetal ball and neoprene seat Four X-86A gate valved outlets (2.5") Liquid-filled pressure gauge (0-300) Fig. 4 OPTIONS THREADS All fireground connections are unless otherwise specified. See index T-12 for optional base threads.
5 PLAIN & CLAPPERED SIAMESE Plain & Clappered Siamese Used to combine several hoselines into one usually in situations where seconds count a Siamese must be both reliable and intuitive to use. Clappers allow additional lines to be added without interrupting flow. As with all Elkhart products, years of dependable service are to be expected from an Elkhart Siamese. While all the Siamese are finished in red urethane enamel, the Elk-O-Lite versions feature hard anodized trim and the brass versions offer satin brass trim. 4-5
6 PLAIN & CLAPPERED SIAMESE INLET SIZE AVAILABLE OUTLET SIZE TYPE Female* 1.5" (X2) 2.5" (X2) 2.5" (X3) Male 1.5" 2.5" 3.0" 4.0" 4.0" 5.0" KEY s = standard o = option * Swivel ** Free swivel Storz** Plain Clappered Single Swinging Independent Spring Loaded DRAIN VALVE.75" ADJUSTABLE RELIEF VALVE MATERIAL Brass Elk-O-Lite DIMENSIONS A 1 s A 2 s Length (Inches) s s s s Weight (Lbs.) MODEL FIGURE FIGURE 1 FIGURE /2A Apparatus mountable 4/4A Apparatus mountable Leather carrying handle Fig. 1 Fig. 2 FIGURE 3 FIGURE Adjustable relief valve ( psi) Locking Storz 9703 Adjustable relief valve ( psi) Locking Storz Fig. 3 Fig. 4 OPTIONS THREADS All fireground connections are unless otherwise specified. See index T-12 for optional base threads. ADDITIONAL INFORMATION Chrome trim available on some brass models. Please inquire with our sales staff. More Siamese options available. See page 4-7.
7 VALVED SIAMESE Valved Siamese Used to combine several hoselines into one usually at the fire scene a Siamese must be both reliable and intuitive to use. All the Siamese are finished in red urethane enamel; the Elk-O-Lite versions feature hard anodized trim and the brass versions offer chrome trim. As with all Elkhart products, years of dependable service are to be expected from an Elkhart Siamese. 4-7 Valve type determines available handle style from 3 options
8 VALVED SIAMESE INLETS 2.5" F (X2) 2.5" F (X3) AVAILABLE OUTLETS Type Female (Swivel) Male (Rigid) Storz (Free Swivel) Female (Swivel) Male (Rigid) Storz (Free Swivel) Size 2.5" 3" 3.5" 4" 4.5" 5" 6" 2.5" 3" 3.5" 4" 4.5" 4" 5" 2.5" 3" 3.5" 4" 4.5" 5" 6" 2.5" 3" 3.5" 4" 4.5" 4" 5" 1/4 Turn Ball Valve TYPE X-86A Gate Valve HANDLE STYLE Crank Self-Locking Twist-Lock Bleeder Valve.75" VALVES Adjustable Relief Valve MATERIAL Brass Elk-O-Lite Length (Inches) DIMENSIONS o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98A 1 o B-98 1 o B-98 1 o B-98A 1 s o s o B-98A 1 s o s o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99A 2 o B-99 2 o B-99 2 o B-99A 2 o B-99 2 s o s o B-99A 2 s o s Weight (Lbs.) MODEL FIGURE 4-8 KEY s = standard o = option
9 VALVED SIAMESE FIGURE 1 FIGURE 3 B-98/B-98A Apparatus mountable Built-in strainer Adjustable neoprene seats 9722 Full, flow Hydro-Loc valves Adjustable relief valve ( psi) FIGURE 2 B-99/B-99A Apparatus mountable Built-in strainer Adjustable neoprene seats Fig. 1 Fig. 2 FIGURE Full, flow Hydro-Loc valves Adjustable relief valve ( psi) Fig. 3 Fig FIGURE Adjustable relief valve ( psi) Fig. 5 OPTIONS ADDITIONAL INFORMATION THREADS All fireground connections are unless otherwise specified. See index T-12 for optional base threads. All twist-locks feature metal knurled knobs. More Siamese options available. See page 4-5.
10 WYES Wyes Used to divide a single flow, usually at a fireground scene, wyes must be both reliable and intuitive to use. Elkhart offers several customizable handle options. All Elkhart wyes give years of dependable service. When necessary, they are easy to field service and re-buildable for continued long-term use. Both 2-way and 3-way wye options available Swivel inlets Customizable handle options All ball valve wyes feature acetal balls with self-adjusting UHMWPE seats.
11 WYES 4-11 INLET SIZE 1.0 (F) 1.5" (F) 2.5" (F) 3.0" (F) 3.5" (F) 4.0" (F) 4.5" (F) 5.0" STORZ 5.0" (F) 6.0" (F) 0.75" (x2) OUTLET SIZE (MALE) TYPE HANDLE STYLE 1" 1.5" 2.5" (x2) (x2) (x2) (x3) Plain Ball Valved Knob Short Elk-O-Lite Long Elk-O-Lite Molded Urethane Positive Twist Lock MATERIAL/ TRIM o o s o B-100-SA 3 o o s o B-100-SA 3 o s B-100-L 3 o o s o B-100-LA A o o s o B-100-A* 3 o s B A s B-97A 2 s B A s B-95A 1 s B A 4 s B-97A 2 s B-97 2 s B-95A 1 s B A s B-97A 2 s B-97 2 s B-95A 1 s B A s B-97A 2 s B-97 2 s B-95A 1 s B-95 1 s B-97A 1 s B-95A 1 s B-97A 2 s B-97 2 s B-95A 1 s B-95 1 s B-97A 2 s B-97 2 s B-95A 1 s B-95 1 Brass / Chrome Elk-O-Lite / Hard Anodized DIMENSIONS Length (Inches) Weight (Lbs.) MODEL FIGURE KEY s = standard o = option * Optional pressure gauge available
12 WYES FIGURE 1 FIGURE 2 B95/B95A (3-WAY) POSITIVE TWIST LOCK Fig. 1 B97/B97A (2-WAY) POSITIVE TWIST LOCK Fig. 2 FIGURE 3 FIGURE B-100/B-100A Fig. 3 1/1A Fig. 4 Figures depict general product types only and are not intended to be inclusive of all product features. OPTIONS HANDLES PRESSURE GAUGE THREADS KNOB SHORT (ELK-O-LITE ) LONG (ELK-O-LITE ) Not all handles available on all models. All twist-locks feature metal knurled knobs. MOLDED URETHANE POSITIVE TWIST LOCK All fireground connections are unless otherwise specified. See index T-12 for optional base threads. PSI RATING While all Elkhart wyes are rated to at least 200 psi (13.79 bar), the products specified below are rated to 300 psi (20.69 bar): B-100-A (2.5" F inlet) B-100-LA (1.5" F inlet) B-100-SA (1.0" F or 1.5" F inlet)
13 PISTON INTAKE Piston Intake Elkhart offers piston intake valves in your choice of materials. All piston valves include a variety of features to make your job easier: folding hand-wheel spinner, durable urethane seat, 4 1 /2 " waterway, 3 /4 " bleeder valve, adjustable relief/dump valve (75 to 250 psi) and a red urethane enamel finish. 4-13
14 PISTON INTAKE TRUCK CONNECTION MATERIAL/ HOSE CONNECTION (Inches) (Inches) TRIM DIMENSIONS Elk-O Female** Male Storz** Female* Brass -Lite Length Weight 3 1 / / / / / o o o o o o o o o o o o o s o o o o o o o o o o o o o s KEY s = standard o = option * Swivel ** Free swivel Chromeplated Hard Anodized (Inches) (Lbs.) MODEL FIGURE Figure 1 Figure Fig. 1 Fig. 2 ADDITIONAL INFORMATION While many piston intake valves have the common issue of corrosion, resulting in minor leaks to complete failure depending on service conditions and water supply; Elkhart s 9786 piston intake valve offers a solution. The replaceable anode electrolytically decomposes, while inhibiting the metal breakdown of the piston intake valve. THREADS All fireground connections are unless otherwise specified. See index T-12 for optional base threads.
MANUAL: Jumbo Siamese and Jumbo Wye
TASK FORCE TIPS FIRE FIGHTING EQUIPMENT MANUAL: Jumbo Siamese and Jumbo Wye INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE Read instruction manual before use. Operation of this device without understanding
More informationMANUAL: Jumbo Gate Valve
MANUAL: Jumbo Gate Valve INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE Read instruction manual before use. Operation of this device without understanding the manual and receiving proper training is a
More informationINSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED WATER SOURCES
COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 5 TOPIC: SUPPLY LINES AND SALVAGE LEVEL OF INSTRUCTION: TIME REQUIRED: THREE HOURS INSTRUCTOR GUIDE MATERIALS: TWO FULLY EQUIPPED PUMPERS STATIC AND PRESSURIZED
More informationFlow Material Length. Weight GPM LPM. Style 3095
Akron Municipal Eductors feature a large, easy to read, and removable metering dial with infinite settings between 0% and 6%. Detents at 1 4, 1 2, 1, 3 and 6%. The Eductors are rated to flow at 200 psi
More informationModel 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual
10-12 Steel Pipe Squeezer Sch. 40 & Sch. 80 Operations Manual 1.0 Introduction This manual is issued as a basic operation manual covering the Regent Model 7989T, Pipe Squeezer and Pump as manufactured
More informationDescription Advanced Features Typical Applications
Series single stage, brass barstock line regulator Description Advanced Features Typical Applications The Series regulators are intended for secondary pressure control of noncorrosive, high purity or liquefied
More informationMANUAL: LDH GATED WYE
MANUAL: LDH GATED WYE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE NOTICE Read Instruction Manual before use. Operation of this device without understanding the manual and receiving proper training
More informationINSTRUCTOR GUIDE REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST EDITION, IFSTA
TOPIC: RELAY PUMPING OPERATIONS LEVEL OF INSTRUCTION: TIME REQUIRED: ONE HOUR INSTRUCTOR GUIDE MATERIALS: APPROPRIATE AUDIO VISUAL SUPPORT REFERENCES: PUMPING APPARATUS DRIVER/OPERATOR HANDBOOK, FIRST
More informationPneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar)
Pneumatic Hand Pumps with no Gauge Connection (scissor handle) AP0V (300 psi / 20 bar) The quickest and most economical way to perform pneumatic field pressure calibrations on pressure transmitters, switches
More informationOperating Instructions Model and Hydrostatic Test Pump
Operating Instructions Model 39300 and 39301 Hydrostatic Test Pump Dimension Weight Pump Style Capacity Pressure Motor Lubrication Control Gauge Inlet Connection Outlet Connection Discharge Hose Hose Ends
More informationPanel-mounted valves Series T, Ø 22.5 mm
Series T, Basic valve 3/2-way, M5 (10/32 UNF) M 5 and G 1/8 2.122 Basic valve 3/2-way, M5 (10/32 UNF) M 5 and G 1/8 2.122 Push button 18-T-23-011 2.126 Mushroom 18-T-23-012 2.126 2-position switch 18-T-23-013
More informationPHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1
PHILADELPHIA FIRE DEPARTMENT HIGH PRESSURE FIRE HYDRANT SYSTEM PFD TRAINING MANUAL SUPPLEMENT ENGINE PRACTICES SUPPLEMENT 101 PAGE 1 SUPPLEMENT 101 101. HIGH PRESSURE FIRE HYDRANT SYSTEM The High Pressure
More informationLOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM HYDRA ASSIST VALVE
LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM HYDRA ASSIST VALVE 45 46 LOS ANGELES COUNTY FIRE DEPARTMENT CONTEXT TRAINING PROGRAM INDIVIDUAL SKILLS HYDRA-ASSIST The Hydra-Assist valve is
More informationALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.
Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass
More informationCalibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New
> Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,
More informationOperating Instructions Model and Hydrostatic Test Pump
Operating Instructions Model 29200 and 2920 Hydrostatic Test Pump Dimension Weight Pump Pressure for 29200 Pump Pressure for 2920 Gauge for 29200 Gauge for 2920 Inlet Connection Outlet Connection Hose
More informationCash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified
Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot
More informationInstruction Manual Updated 7/26/2011 Ver. 2.2
4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:
More informationMANUAL: LDH GATED WYE
MANUAL: LDH GATED WYE INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE NOTICE Read Instruction Manual before use. Operation of this device without understanding the manual and receiving proper training
More informationApparatus Operator Refresher Training Program
Division of Training In-Service Training Program Apparatus Operator Refresher Training Program 1 Single Engine / Single Line Operation Refresher Evolution #1 Objective: Charging single handlines at correct
More informationTurboDraft Fire Eductor
TurboDraft Fire Eductor Operating Manual Introduction The TurboDraft is designed to be used for rural water supply operations. Many of us take for granted that there is a fire hydrant on every corner.
More informationChoosing the right miniature instrument and control valve is a snap
Choosing the right miniature instrument and control valve is a snap INVALCO Micro Valve The Micro Valve is a unique miniature valve offering versatility and rugged construction. Since its introduction
More informationPremium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.
Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces
More informationSPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION
DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds
More informationTECHNICAL DATA. TRIMPAC Model B-5 & B-5B
September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on
More information2.0 INSTALLATION & SERVICE
Installation, Operation, and Maintenance Instructions MODEL 5600 / 5600R January 2005 CONTENTS 1.0 GENERAL 1.1 5600 Model Number Information -----------------------------------------------------------------------
More informationData Sheet Issue A
Features 1. Differential-type valve, lightweight, dependable construction. 2. Low Air Pressurized System, 10 psi -to- 26 psi (0,7 bar -to- 1,8 bar). 3. Reset externally.cover removal is not required. 4.
More informationHORIZONTAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationHANNAY REELS. Rescue Reels
Rescue Reels HANNAY REELS For use for: Haz-mat situations Vehicular extrications At-the-scene emergencies reathing and utility air applications H-9406-R Revision 5 INTRODUTION Hannay s Triad Rescue Reels
More informationPressure reducing valves Index
Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel
More informationPlease Contact Do It American for Pricing
J Product List Please Contact Do It American for Pricing BK-22-01 27.2 Cu. Ft. Portable Bypass System Box and Regulation only (7 IWC) BK-22-02 27.2 Cu. Ft. Portable Bypass System Box, Regulation, and Cylinder
More information12 Impeller Replacement
144 Impeller Replacement INTRODUCTION Jabsco The Original Impeller Jabsco Flexible Impellers can be fitted to most makes and models of bronze flexible impeller engine cooling, bilge, transfer and general
More informationHead to Head Demo Comparison Sheet
Head to Head Demo Comparison Sheet Task Force Tips Crossfire Portable/Deck Mount Monitor The purpose of this document is to encourage you to compare TFT products head to head, apples to apples, with like
More informationALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data
ir line equipment Miniature eneral Purpose egulators 7, (non-repairable) 7 Full flow gauge ports Snap action knob locks pressure setting when pushed in Standard relieving models allow reduction of outlet
More informationHIGH FLOW HIGH PRESSURE PUMP type BMS
When you have to test objects on different locations within your workshop, the mobile pump system BMS gives you the possibility to test adequately on different sites. Through its wheels (or forklift pockets)
More informationSpecialty Products. Specialty Products Index
Specialty Products MAXIMATOR has been designing and manufacturing specialty products to serve the high pressure market for over thirty years and has a worldwide reputation for quality and reliability.
More informationLQ Series Connectors. What is the LQ2?
LQ Series Connectors LQ2 Connections Frequently Asked Questions What is the LQ2? The LQ2 Series connectors are the latest addition to CPC s liquid cooling of electronics (LCoE) Series. For liquid cooling
More informationTECHNICAL DATA. Page 1 of 12
Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control
More informationSABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company
CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN
More information!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7
EXEL North America, Inc. EXEL Industrial Canada, Inc. 1310 Washington St 931 Progress Ave., #7 West Chicago, IL 60185 Scarborough ONT, M1G 3V5 Ph : (800) 573 5554 Ph : (800) 450 0655 Fx : (800) 664 1511
More informationVERTICAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationData Sheet Issue A
Features 1. Differential latching clappertype, lighweight, dependable construction. 2. Low Air Pressurized System, 8 psi -to- 26 psi (0,6 bar to- 1,8 bar) 3. Reset externally. Cover removal is not required.
More informationBall valve HKSF-W100. Ball valve HKSF-W100. RMA Kehl GmbH & Co. KG Oststrasse 17 D Kehl / Germany
Ball valve HKSF-W100 RMA Kehl GmbH & Co. KG Oststrasse 17 D-77694 Kehl / Germany info@rma-kehl.de www.rma-armaturen.de 1 Design Features: RMA-ball valves type HKSF-W are fully welded and completely maintenance-free
More informationAdvantage 4000 Abrasi-Blast Respirator
Advantage 4000 Abrasi-Blast Respirator Features Constant Flow Air-Line Respirator and Constant Flow Duo-Flo Respirator options Choice of shoulder length or waist length hoods to meet various blasting applications
More informationSTYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS
STYLE 3414/3416 & 3421/3423 Apollo Monitor with Foldaway Legs OPERATING & MAINTENANCE INSTRUCTIONS The Akron Style 3414/3416 & 3421/3423 Apollo Monitor is designed to provide efficient trouble-free operation
More informationOperating Instructions Models and Hydrostatic Test Pumps
Operating Instructions Models 46453 and 464530 Hydrostatic Test Pumps 46453 DIMENSIONS: 27 (67.5cm) L x 22 (55cm) W x 34 (85cm) H WEIGHT: 160 lbs. 73 kg PUMP: Twin piston: Positive displacement type Inlet
More informationMANUAL: 5-WAY MANIFOLD
MANUAL: 5-WAY MANIFOLD INSTRUCTIONS FOR SAFE OPERATION AND MAINTENANCE NOTICE NOTICE Read Instruction Manual before use. Operation of this manifold without understanding the manual and receiving proper
More informationAPOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, ANDMAINTENANCE INSTRUCTIONS
APOLLO HI-RISER MONITOR STYLE 3433/3431 INSTALLATION, OPERATING, ANDMAINTENANCE INSTRUCTIONS The following is intended to provide the basic instructions for installation, operation and maintenance of the
More informationPrecision and Instrument Regulators 1/4" port size
Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38
More informationF l o w c o n T R o l v a l v E S
Composite Right Angle Flow Control Valves Series TMCU-TMVU-TMCO- BSP/METRIC Meter In, Meter Out, Needle Orifice G1/8, G1/, G3/8, G1/2 Banjo flow controllers Nominal diameters Ø 2-3.8-5.8-8 The Meter In,
More informationModel DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.
Bulletin 335 Model DDX-LP Dry Pipe Valve System 8 (200mm) Bulletin 335 Features 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Differential latching clapper-type, lighweight, dependable construction. Low Air Pressurized
More informationFILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS
FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.
More informationDESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection
February 9, 1998 Foam 201a 1. DESCRIPTION A Deluge Bladder Tank Foam/Water System is a standard deluge system capable of discharging a foam/water solution automatically through open sprinklers, spray nozzles,
More informationFeatures. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes
Bulletin 357 Rev. E Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes Bulletin 357 Rev. E Features 1. 2. 3. 4. 5. 6. 7. 8. 9. Differential-type valve, lightweight, dependable construction.
More informationFirst Stage Regulators
DOMESTIC First stage regulators are typically used to reduce tank pressure to an intermediate pressure, usually 5 to 10 PSI for further pressure reduction by a second stage regulator located closer to
More informationTECHNICAL DATA. Pressure Regulation 531a. April 24, 2009
April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking
More informationAIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES
Series AIR CHUCKS, TIRE GAUGES AND INFLATOR GAUGES Standard Air Chucks 374 Flow-Thru Air Chucks 375 Standard Pencil Tire Gauges 376 Dual Foot Tire Gauges 377 Dial Tire Gauges 378 Digital Tire Gauges 379
More informationDirect Operated Precision Regulator Modular Style. Standard Specifications
1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com
More informationTECHNICAL DATA. Trimpac 251a. Spetember 16, 2013
Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release
More informationSIMPLAIR PIPING TOOL. JXT Company
SIMPLAIR PIPING INGERSOLL-RAND SIMPLAIR PIPING With push-in fittings and lightweight anodized aluminum pipe, a SimplAir system provides ideal connection throughout your entire air distribution system.
More informationTITAN Oxygen Regulators
EMS OXYGEN REGULATORS TITAN Oxygen Regulators EMS TITAN SERIES OXYGEN EMS AND FIRE SERVICE APPLICATIONS CLICK-STYLE REGULATOR Whether its EMS, ambulance, fire rescue or tactical medical use, Titan Oxygen
More informationshutoff valves 900 Series psig Manual Shutoff Valves
0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on
More informationDESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE
February 9, 1998 Foam 101a A BLADDER TANK WITH 1. DESCRIPTION A Wet Pipe Bladder Tank Foam/Water System is a standard wet pipe automatic sprinkler system capable of discharging a foam/water solution automatically
More informationStorage Systems and Accessories
Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single
More informationNorth American Orifice Metering System
Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual
More informationTECHNICAL DATA CAUTION
Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking
More informationHose & Reel. Rescue Hose Reels. Haz-mat Situations Vehicular Extrications. At-the-scene Emergencies Breathing and Utility Air Applications
Hose & Reel P R O D U C T S Rescue Hose Reels Haz-mat Situations Vehicular Extrications At-the-scene Emergencies Breathing and Utility Air Applications 2 Note to the designers & engineers. Rescue Reels
More informationDescription Supply pressure Pressure range Connection Device Page max. bar bar thread
Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4
More informationCash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified
Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified TYPE G-4 DESCRIPTION FIG 2042 - Bronze FIG 2043 - Bronze
More information1200 Series Pressure Regulators
SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of
More informationAUTOMATIC HOSE TEST UNIT, TYPE SPU
VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE
More informationHP/UHP Spring-Loaded Regulator
Description HP (High Purity) and UHP (Ultra High Purity) products are for service where the product must be kept free of contamination. The design is kept simple to minimise dead areas where contaminants
More informationNozzles and portable monitors
Nozzles and portable monitors Rosenbauer Nozzles and portable monitors Nozzles and portable monitors. EN maximum extinguishing effect. The Rosenbauer nozzle enables the manual 4-stage adjustment of the
More information61R2 STANDARD REGULATOR COMPACT REGULATOR. Phone Fax
6R STANDARD REGULATOR COMPACT REGULATOR 496 Phone 7.63.888 Fax 7.63.690 6R AND 496 REGULATORS General Information The Model 6R and 496 Compact Regulator (CR) are designed to deliver reliable and safe regulation
More informationBladder Tank Installation & System Design Information
Bladder Tank Installation & System Design Information The Chemguard Bladder Tank is one component in a balanced pressure foam proportioning fire protection system. It requires no external power other than
More informationTECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13
Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationStandard Specifications
NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max.
More informationSpeed control assembly model A-1
Pressure Regulation 533a 1. DESCRIPTION The Viking Speed Control Assembly provides adjustment of the opening speed of Viking Deluge Valves, and adjustment of both the opening and closing speed of Viking
More informationRelief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm
s s RS Differential NB 9.5mm RVA In-line Differential NB 6 to 19mm RV Direct Acting NB up to 9mm LPR Low Pressure Differential NB 8mm We design, machine, build and test all our products on one site in
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationMEDICAL CYLINDER VALVES
MEDICAL CYLINDER VALVES 3 1 Medical integrated valve for oxygen air and medical mixture 1.1 ALIONE 1.2 ALPINOX-valve 1.3 ALPINOX-valve compact 2 Cylinder valve with RPV for oxygen and medical gases -
More informationTECHNICAL DATA. Trimpac 244a. September 16, 2013
September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally
More informationPressure Equalising Valves Model , for Differential Pressure Gauges
Accessories Pressure Equalising Valves Model 910.25, for Differential Pressure Gauges WIKA Data Sheet AC 09.11 Applications T Isolating, pressure equalising as well as purging and air bleeding valves to
More informationA BRIEF TUTORIAL ON GAS HANDLING EQUIPMENT
TABLE OF CONTENTS BACK PRESSURE REGULATORS...26 CGA CONNECTION DRAWINGS...102 CGA CYLINDER CONNECTIONS AND GASKETS...98 CHANGEOVER MANIFOLDS...60-63,65 CHECK VALVES...70 CONVERSION TABLES...103 CUSTOM
More informationBLAST-IT-ALL. TOLL FREE: (800)
BLAST-IT-ALL TOLL FREE: (800) 535-2612 sales@blast-it-all.com www.blast-it-all.com BLAST-IT-ALL TOLL FREE: (800) 535-2612 sales@blast-it-all.com www.blast-it-all.com MICROVALVE The MicroValve gives you
More informationFOAM TANK (1/2) DATA SHEET
FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 0 PROJECT : QUANTITY : 0 LOCATION : SERVICE : FOAM SYSTEM 0 05 CODE & STANDARDS
More informationWater. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912
Water VAG DUOJET Automatic Air Valve Single-chamber type Product characteristics and benefits Resilient seated With flange end acc. to EN 1092-2 Single chamber air valve in compact design Very high discharge
More informationTONS! powerteam.com HEAVY LIFT CYLINDERS
NEW DESIGNS TONS! powerteam.com HEAVY LIFT CYLINDERS THE Precise MOST Positioning COMPREHENSIVE & ControlRANGE OF HIGH in a Responsive PRESSURE Package HEAVY LIFT CYLINDERS R_G SINGLE & DOUBLE ACTING,
More informationOperating Instructions Models and Hydrostatic Test Pumps
Operating Instructions Models 36454 and 364540 Hydrostatic Test Pumps 36454 DIMENSIONS: 24 (61cm) L x 19 (48cm) W x 19.5 (50cm) H WEIGHT: 135 lbs 61.5 kg PUMP: Twin piston: Positive displacement type Inlet
More informationS300 Series. Valve Link. Features. Fisher Controls
S0 Series Self-Operated Type VL FIELDVUE Regulators Valve Link Fisher Controls May 198 Bulletin 71.1:S0 The S0 Series self-operated, spring-loaded regulators are used for pressure-reducing control in a
More informationB84G - Excelon Plus Modular System General purpose filter/regulator
> Port size: 3/8" to 3/4" (PTF/ISO G) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Push to lock adjusting knob with built in tamper resistant
More informationOperating Manual. Models MP-23ENBC, MP-23LPANB, MP-23EHNBC, MP-2300HNB
Models MP-23ENBC, MP-23LPANB, MP-23EHNBC, MP-2300HNB Manual No. AIRCRT22 (Rev 1 July 2007) Operating Manual AIR SYSTEMS INTERNATIONAL, INC. 829 Juniper Crescent, Chesapeake, Va., 23320 Telephone (757)
More informationSUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation. Size: inch / mm
SUBMITTAL NOTES PROJECT: Ross Model 50RWR-A Pilot Operated Surge Relief Valve with Hydraulic Anticipation Size: inch / mm Every Ross Valve shall be hydrostatically tested for body integrity and tight seating
More informationEvaluating 2-1/2 Direct Fill Lines Colton, New York
www.gotbigwater.com Tanker Fill Tests Evaluating 2-1/2 Direct Fill Lines Colton, New York August 24, 2008 Overview On August 23 rd and 24 th, 2008, the Colton (NY) Fire District hosted a Rural Water Supply
More informationREGULATORS FOR SPECIFIC APPLICATIONS
SINGLE-STAGE REGULATORS FOR NITROUS OXIDE AND CARBON DIOXIDE (MODELS SG9011, SG9012, SG9014) Nitrous Oxide and Carbon Dioxide frequently cause ordinary regulators to freeze up. Models SG9011, SG9012 and
More informationModular Type Regulators
Modular Type Regulators Series AR AC Regulator Series AR Port size Options AFARAL, 1/4 Bracket AFAR AWAL AR4-A, 1/2 Round type pressure gauge With set nut (for panel mount) AFAFMAR P.45 to 5 AR4-6-A ot
More informationPneumatic Powered - Plunger Pumps
Models 42/62/82 D Series P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pumps Suggested Installation & Operating Instructions
More informationAIR DISTRIBUTOR. PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB
Manual #: MM-AD001 12/5/11 Rev. A Page 1 of 8 PART NUMBER (Including, but not inclusive) AD28483-_ALB, AD28563-_ALB, AD36097-_ALB, AD36098-_ALB, AD28485-_ALB Manual #: MM-AD001 12/5/11 Rev. A Page 2 of
More informationWHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual
WHEATLEY SERIES 500 SWING CHECK VALVE STANDARD INTEGRAL SEAT & OPTIONAL REMOVABLE SEAT 2" FP - 6" FP 150# - 1500# 8" FP - 12" FP 150# - 900# API 6D and B16.34 2" FP - 4" FP 5000# DRILLING PRODUCTION VALVE
More informationNickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO
Nickel-Plated Brass Right Angle Flow Control Valves NPTF/Inch Series GSCU, GMCU, GSVU, GMVU, GSCO, GMCO Swivel Design : Meter-Out, Meter-In and Needle Orifice Tube Diameter OD: 1/8, 5/2, 1/4, 5/16, /8
More information