1 Brueninghaus Hydromatik Variable Displacement Pump A1VO Series 5, open circuits, SAE-Version Axialpiston, swash plate design size 28 6 Nominal pressure 2 bar Peak pressure 315 bar RE 9273/4.96 replaces 8.91 RE 9273/4.96 The variable displacement axial piston pump A1VO in swashplate design was designed for hydrostatic drives in open circuits. Flow is proportional to the drive speed and the displacement. By adjusting the position of the swashplate it is possible to vary the flow steplessly. Strong bearings for long life High permissible drive speed High power-weight ratio Small dimensions Low noise level Good suction characteristics Permissible continous pressure 2 bar Axial and radial loading of drive possible Pressure and flow control Short control times 2 drain ports Brueninghaus Hydromatik 1

2 Type Code A1V O / 52 N Fluid Mineral oil (no desig.) Axial piston unit Variable, swashplate design SAE nominal pressure 2 bar, peak pressure 315 bar A1V Mode of operation Pump, open circuit O Size Displacement V g max (cm 3 ) Control devices Pressure control DR DR Pressure-remote control DRG DRG Pressure- and flow control DFR DFR DFR 1 DFR1 without orifice between X and tank Series Direction of rotation Looking at drive Seals NBR (Nitrile rubber to DIN ISO 1629) FPM (Fluoride rubber to DIN ISO 1629) 52 clockwise counter clockwise R L P V Shaft end Splined SAE 7/8" 1" 1 1/4" Splined SAE (higher through drive torque) 1" Splined SAE (not suitable for through drive) 7/8" Mounting flange SAE 2-bolt SAE 4-bolt S R U C D Service ports Pressure port B Inlet port S SAE- threaded rear Pressure port B Inlet port S SAE- flange rear - UNC threads Pressure port B Inlet port S SAE- flange rear - metric threads Pressure port B SAE- flange side ports Inlet port S UNC - threads Pressure port B SAE- flange side ports Inlet port S metric threads Through drive without through drive N Mounting flange -coupler to mount: 11-2 (SAE B) 22-4 (SAE B) A1VO 28 ( S) K (SAE B) 25-4 (SAE B-B) A1VO 45 ( S) K (SAE C) 32-4 (SAE C) A1VO 6 ( S) K only possible without through drive = available = in preparation = not available 2 Brueninghaus Hydromatik

3 Hydraulic fluid Prior to project design, please see our catalogue sheets RE 922 (mineral oils) and RE 9221 (environmentally compatible fluids) for detailed information on the selection of hydraulic fluids and application conditions. When operating with environmentally compatible fluids certain limitations may apply. Please consult us. Operating viscosity range For optimum efficiency and service life, we recommend that the operating viscosity (at operating temperature) be selected in the range ν opt = optimum operating viscosity mm 2 /s referred to tank temperature (open circuit). referred to tank temperature (open loop circuit). Limits of viscosity range The following values are valid for extreme operating conditions: ν min = 1 mm 2 /s for short periods at max. leakage oil temperature of 9 C. ν max = 1 mm 2 /s for short periods upon cold start. Selection diagramm VG 22 VG 32 VG 68 VG 46 VG 1 Temperature range (see selection diagram) t min = 25 C t max = +9 C Notes on the selection of the hydraulic fluid For correct selection of the fluid it is assumed that the operating temperature in the tank is known (open circuits), in relation to the ambient temperature. The hydraulic fluid should be selected so that, within the operating temperature range, the operating viscosity lies within the optimum range ν opt, (see shaded section of selection diagram). We recommend that the higher viscosity grade is selected in each case. Example: At an ambient temperature of X C the operating temperature in the tank will be 6 C. In the optimum operating viscosity range (ν opt ; shaded section) this corresponds to viscosity grade VG 46 or VG 68; VG 68 should be selected. Important: The leakage oil temperature is influenced by pressure and speed and is always higher than the tank temperature. At no point in the system, however, may the temperature be higher than 9 C. If it is not possible to comply with the above conditions because of extreme operating parameters or a high ambient temperature, please consult us. Viskosität ν (mm/s) Viscosity ν (mm 2 /s) ν opt t min = 25 C Druckflüssigkeitstemperaturbereich Fluid temperature range Filtration In order to guarantee reliable function, the operating fluid must be maintained to a cleanliness grade of minimum 9 to NAS 1638 or 6 to SAE 18/15 to ISO/DIS 446 This may be achieved for example with filter elements, type...d 2...(see RE 75). This gives a filtration quotient of β Temperature t ( C) t( o C) t max = + 9 C Brueninghaus Hydromatik 3

4 Technical Data Operating pressure range - Inlet side Absolute pressure at port S (inlet port) p abs min,8 bar p abs max 3 bar Operating pressure range - Outlet side pressure at port B Nominal pressure p N 2 bar Peak pressure p max 315 bar (Pressure data to DIN 24312) Direction of flow S to B. Case drain pressure Maximum permissible pressure of leakage fluid (at port L, L 1 ): maximum,5 bar higher than the inlet pressure at port S, but not higher than 2 bar absolute. Determination of inlet pressure p abs at the inlet port, resp. the reduction in displacement for increasing speed. Speed n/n max 1,2 1,1 1,,9,7,8,9 1, Displacement V g /V gmax 1,6 1,4 1,2 1,,9,8 Inlet pressure p abs (bar) Table of values (theoretical values, without considering η mh and η v ; values rounded) Size Displacement V g max cm Max. speed 1 ) at V g max n o max min ) 27 Max. flow at n o max Q o max L/min at n E = 14 rpm L/min Max. power ( p = 2 bar) at n o max P o max kw at n E = 14 rpm kw Max. torque ( p = 2 bar) at V g max M max Nm Moment of inertia about drive axis J kgm 2,17,33,56 Fill capacity L,3,5,8 Approx. weight (without oil fill) m kg Permissible loading on drive : max. perm. axial force F ax max N max. perm. radial force F q max N ) The values shown are valid provided there is an absolute pressure of 1 bar at suction inlet S. By increasing the inlet pressure (p abs >1bar) or reduction of the diplacement, the speed can be raised up to the maximum speed limit (see diagram). 2 ) Higher drive speed on request Direction of force± Fax F q X/2 X/2 X Calculation of size V g n η v Flow Q = [L/min] Drive torque M = 1 1,59 V g p [Nm] 1 η mh Drive power 2π M n P = M n = = Q p [kw] η t V g = geometr. displacement [cm 3 ] per rev. p = pressure differential [bar] n = speed [rpm] η v = volumetric efficiency η mh = mech.-hydr. efficiency η t = overall efficiency (η t = η v η mh ) 4 Brueninghaus Hydromatik

5 Operating Curves for Pump with Pressure Control DR Noise level Measured in an anechoic chamber to DIN Distance from microphone to pump = 1 m Measuring error to DIN 45635, part 1: ± 2 db (A) (Fluid: hydraulic oil to ISO VG 46 DIN 51519, t = C) Size 28 Size Q max n = 1 rpm 75 Q n = 3 rpm min 73 Q n = 3 min rpm -1 max 9 71 Q min 8 69 n = 1 min rpm -1 6 Q Noise level L A [db(a)] Operating pressure p [bar] Drive power and output flow (fluid: mineral oil to ISO VG 46 DIN 51519, t = C) Flow Q [L/min] P Qmin Operating pressure p [bar] P Qmax Drive power P[kW] Size 45 8 Noise level L A [db(a)] n = 26 min rpm -1 n = 1 min rpm Operating pressure p [bar] Q max Q min Q max Q min 2 Flow Q [L/min] Size 45 n = 1 rpm n = 26 rpm Q 6 P 4 Qmax 3 2 P Qmin Operating pressure p [bar] Drive power P[kW] Size 6 Size 6 Noise level L A [db(a)] n = 27 min -1 n = 1 min -1 Q max Q min Q max Q min n = 1 rpm n = 27 rpm Flow Q [L/min] Q P Qmax P Qmin Drive power P[kW] Operating pressure p [bar] Operating pressure p [bar] 2 Brueninghaus Hydromatik 5

6 Installation Notes Installation position is optional. The pump housing must be filled with fluid during commissioning and remain full when operating. In order to achieve the lowest noise value, all connections (suction, pressure, case drain ports) must be linked by flexible couplings to tank. Avoid placing a check valve in the case drain line. This may, however, be permissible in individual cases, after consultation with us. 1. Vertical installation ( end upwards) The following installation conditions must be taken into account: 1.1. Arrangement in tank Before installation fill pump housing, keeping it in a horizontal position. a) If the minimum fluid level is equal to or above the pump mounting surface leave ports L, "L 1 " and S open (see Fig.1). b) If the minimum fluid level is below the pump mounting surface pipe port L 1, and possibly S according to Fig. 2. Close port "L" with respect to conditions in Fluid 2. Horizontal installation The pump must be installed, so that "L" or "L 1 " is at the top Installation within a tank a) If the minimum fluid level is equal to or above the top of the pump,ports "L", "L 1 " and S should remain open (see fig. 3) b) If the minimum fluid level is below the top of the pump, pipe ports "L", "L 1 " and possibly "S" as fig. 4. The conditions correspond to item L 1 L Fluid S p In min fig. 3 S 1.2. Installation outside a tank Before installing the pump, fill the pump with housing in the horizontal position.for mounting above a tank see fig. 2. Limiting conditions: Minimum pump inlet pressure p in min =,8 bar both static and dynamic conditions. Note: Avoid mounting above a tank wherever possible in order to achieve a low noise level. The permissible suction height h comes from the overall pressure loss, but may not be bigger than h max = 8 mm (immersion depth h d min = 2 mm). L 1 S Fluid L 1 L fig. 1 h max h d min L fig Installation outside a tank Fill the pump housing before commissioning. Pipe ports "S" and the higher port "L" or "L 1 ". a) When mounting above the tank, see fig. 4. Conditions correspond to L L 1 b) Mounting below the tank Pipe ports "L" and S according to fig.5. Fluid Fluid S fig. 4 p In min h max Overall pressure loss p total = p 1 + p 2 + p 3 (1 p in. min ) =,2 bar p 1 : Pressure loss in pipe due to accelerating column of fluid ρ l dv p 1 = 1 5 (bar) dt ρ = density (kg/m 3 ) l = pipe lenght (m) dv/dt = change in rate of fluid velocity (m/s 2 ) p 2 : Pressure loss due to static head p 2 = h ρ g 1 5 (bar) h = head (m) ρ = density (kg/m 3 ) g = gravity. = 9,81 m/s 2 p 3 : Line losses (elbows etc.) 6 Brueninghaus Hydromatik L L 1 p In min S fig. 5

7 2 tief ø32 58,7 ø ø11,6h8 ø7/8" RE 9273/4.96 Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision. Dimensions size 28 DR Version A1VO 28 DFR 61 DFR1 /52 R -X S C 64 N DRG 12 9,5 6, /4-16UNF-2B Flansch Flange 11-2 SAE J744 OCT ,3 123,5 45 1/4-2UNC-2B W 97,3 68, ,1 27 7, ; Welle 22-4; SAE SAE J744 J744 OCT 7/8" Keilwellengröße; 3 o 83 Eingriffswinkel; 13 Zähne; 3 o pressure 16/32 Pich-Tlg.; angle; abgeflachter 13 teeth, Lückengrund; Flankenzentrierung; Toleranzklasse 5; ANSI B92.1a-1976 L View W Portplate 64 shown is clockwise rotation /16-2UNF-2B 1 deep View W Portplate 61 shown is clockwise rotation 1 5/8-12UN-2B deep /16-12UN-2B 2 tief 17 deep SAE 1 1/4" standard Standarddruckreihe pressure range 7/16-14UNC-2B 24 tief deep 3, ,2 SAE 3/4" standard Standarddruckreihe pressure range 3/8-16 UNC tief deep For ccw - rotation, turn port plate 18 o For ccw - rotation, turn port plate 18 o Ports B Pressure port 1 1/16-2UN-2B S Inlet port 1 5/8-12UN-2B L/L 1 Case drain 3/4-16UNF-2B X Pilot port 7/16-2UNF-2B in model pressure control DR pilot port X is plugged Ports B Pressure port SAE 3/4" (Standard pressure range) S Inlet port SAE 1 1/4" (Standard pressure range) L/L 1 Case drain 3/4-16UNF-2B X Pilot port 7/16-2UNF-2B in model pressure control DR pilot port X is plugged Brueninghaus Hydromatik 7

8 Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision. Dimensions size 45 Pressure control DR Version A1VO 45 DR /52 R-X S C 11 N 61 Flansch Flange 11-2 SAE J744 OCT ; SAE J744 OCT 83 3 pressure angle, 15 teeth, View W Portplate 11/61 Shaft S 3 o pressure angle, 15 teeth, Shaft R w. plate 11 N M 12; 2 deep w. plate 61 N 1/2-13UNC-2B w. plate 11 N M 1; 17 deep w. plate 61 N 3/8-16UNC-2B Shown for clockwise rotation For ccw - rotation, turn port plate 18 o 3 o pressure angle, 15 teeth, useble spline length Shaft U 3 o pressure angle, 13 teeth, Ports B Pressure port SAE 1" (Standard pressure range) S Inlet port SAE 1 1/2" (Standard pressure range) L/L 1 Case drain 7/8-14UNF-2B 8 Brueninghaus Hydromatik

9 Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision. Dimensions size 45 Version A1VO 45 DFR /52 R- X S C 64 N DRG Flange Flansch 11-2 SAE J744 OCT 83 ø11,6 h ; SAE J744 OCT 83 3 pressure angle, 15 teeth; View W Portplate 64 Shaft S 2 deep 7/16-2UNF-2B 1 deep 3 o pressure angle, 15 teeth, Shaft R Shown is clockwise rotation For ccw - rotation, turn port plate 18 o 2 deep 3 o pressure angle, 15 teeth, useble spline length Shaft U 3 o pressure angle, 13 teeth, Ports B Pressure port 1 5/16-12UN-2B S Inlet port 1 7/8-12UN-2B L/L 1 Case drain 7/8-14-UNF-2B X Pilot port 7/16-2UNF-2B Brueninghaus Hydromatik 9

10 Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision. Dimensions size 45 Version A1VO 45 DFR /52 R- X U C 12 N DRG 62 Flange 11-2 SAE J744 OCT 83 ø11,6 h8 standard pressure range w. plate 12 N M 12; 2 deep w. plate 62 N 1/2-13UNC-2B 22-4; SAE J744 OCT 83 3 pressure angle, 13 teeth; View W Shaft S View V 7/16-2UNF-2B 1 deep 3 o pressure angle, 15 teeth, Shaft R standard pressure range w.plate 12 N M 1; 17 deep w. plate 62 N 3/8-16UNC-2B Shown for clockwise rotation For ccw - rotation, turn port plate 18 o 3 o pressure angle, 15 teeth, useble spline length Shaft U 3 o pressure angle, 13 teeth, Ports B Pressure port SAE 1" (Standard pressure range) S Inlet port SAE 1 1/2" (Standard pressure range) L/L 1 Case drain 7/8-14UNF-2B X Pilot drain 7/16-2UNF-2B 1 Brueninghaus Hydromatik

11 ,5 137 RE 9273/4.96 Prior to finalising your design, please request certified installation drawing. All rights reserved subject to revision. Dimensions size 6 Version A1VO 6 DR DFR /52 R- X S C 61 N DRG , Flansch flange SAE J744 OCT 83 7/8-14UNF-2B 7/8-14UNF-2B 14,3 ø127h8 ø1 1/4" 5/16-18UNC-2B W 78,5 6 View W Port plate X 12,5 7/16-2UNF-2B 1 deep ,5 55,4 7, , ,8 32-4; SAE J744 OCT 83 3 pressure angle, 14 teeth; 12/24 DP ø S B ø 25 52,4 S SAE 2" Standarddruckreihe pressure range 1/2-13UNC-2B 22 tief deep 42, Shown for clockwise rotation For ccw - rotation, turn port plate 18 o 26,2 B SAE 1" Standarddruckreihe pressure range 3/8-16UNC-2B 18 tief deep Ports B Pressure port SAE 1" (Standard pressure range) S Inlet port SAE 2" (Standard pressure range) L/L 1 Case drain 7/8-14UNF-2B X Pilot port 7/16-2UNF-2B in model pressure control DR pilot port X is plugged Brueninghaus Hydromatik 11

12 DR Pressure control The pressure control serves to maintain a constant pressure in the hydraulic system, within the control range of the pump. The pump therefore supplies only the amount of hydraulic fluid required by the actuators. Pressure may be steplessly set at the pilot valve. Dimensions see page 7,8 and 11. Static characteristic (at n 1 = 1 rpm; t oil = C) hysteresis and pressure increase p max 4 bar Q max Flow Q Q min setting range 2 2 Operating pressure p (bar) Control oil cosumption max. 3 L/min. Dynamic characteristics The curves show average measured values under test conditions, unit in the tank. Conditions: n = 1 rpm t oil = C Line relief valve set at 315 bar Stepped loading by suddenly opening or closing the pressure line using a pressure relief valve at 1m downstream from the axial piston unit. Operating pressure p [bar] V g max V gmax Displacement (swivel angel) V g min V gmin Control time t stroking time t SA de-stroking time t SE Size t SA (ms) t SA (ms) t SE (ms) against bar against 22 bar zero stroke 2 bar Brueninghaus Hydromatik

13 DRG Pressure control, remote control Function and design as for DR. A pressure relief valve may be externally piped to port X for remote control purposes. It is not, however, included with the DRG control. The differential pressure at the pilot valve is set as standard to 2 bar and this results in a pilot flow of 1,5 L/min. If another setting is required (in the range 1 22 bar), please state this in clear text. We recommend that one of the following is used as the separate pressure relief valve: DBDH 6 (hydraulic) to RE 2542, DBEC-3X (electrical) to RE or DBETR-SO 381 with,8 mm dia. nozzle in P (electrical) to RE The length of piping must not exceed 2m. Not included in supply Static characteristic (at n 1 = 1 rpm; t oil = C) hysteresis and pressure increase p Flow Q setting range 2 2 Operating pressure p [bar] Dimensions see pages 7, 9, 1 and 11. Control data Hysteresis and repetitive accuracy p...max. 3 bar Max. pressure increase Size p bar Control oil consumption... approx. 4,5 L/min Flow loss at Q max see page 5. Brueninghaus Hydromatik 13

14 DFR/DFR1 Pressure/flow control In addition to the pressure control function, the pump flow may be varied by means of a differential pressure at the actuator (e.g. an orifice, not included in supply). The pump flow is equal to the actual required flow by the actuator. The DFR1-valve has no connection between X and tank. Dimensions see pages 7, 9, 1 and 11. Static characteristic (at n 1 = 1 rpm; t oil = C) not included in supply with DFR1 no connection Q max max Flow Q Setting range Q (see table of values) Q min min 2 Operating pressure p (bar) 2 Static characteristic at variable speed Q Q max max Flow Q Q (see table of values) Q min Q min Speed n n max (rpm) Max. Flow deviation (hysteresis and increase) measured at drive speed n = 1 rpm Size Q L/min 1, 1,8 2,5 Dynamic characteristic of flow control The curves shown are measured average values under test conditions, with the unit within the tank. Displacement V g (%) stroking time t SA (stand by) Control time t de-sroking time t SE t SA (ms) t SE (ms) t Size SE stand by 2 bar 2 bar stand by bar stand by 28 upon request upon request Load pressure p (bar) Control oil consumption max. 3 L/min. Flow control/differential pressure p: Adjustable between 1 and 22 bar Standard setting: 14 bar. If a different setting is required, please state in clear text. When port X is unloaded to tank, a zero stroke pressure of p =18 ± 2 bar ("stand by") results. Optional valves at port B (not included in supply) Mobile valve blocks SP 12 (RE 64145) Mobile valve blocks SP 18 (RE 64148) Mobile valve blocks MP 18 (RE 64594) Mobile valve blocks MP 22 (RE 64598) Proportional directional valves 4WRE (RE 296) 14 Brueninghaus Hydromatik

15 Brueninghaus Hydromatik 15

16 Brueninghaus Hydromatik GmbH, Werk Horb, D 7216 Horb, An den Kelterwiesen 14, Tel. (7451) 92, Telex , Fax (7451) Brueninghaus Hydromatik

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary

More information

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents

More information

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Fixed Displacement Pump KFA for commercial vehicles in open circuits RE 91 501/05.98 Replaces: 11.96 Fixed Displacement Pump KFA for commercial vehicles in open circuits Sizes 23...107 Series 6 Nominal pressure 300 bar Peak pressure 350 bar KFA List of contents Features

More information

Fixed Displacement Motor A4FM

Fixed Displacement Motor A4FM Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91 1 for open and closed circuits Sizes 22...5 Series 1, Series 3 Nominal pressure up to bar Peak pressure up to 45 bar Index Features 1 Ordering

More information

Fixed Displacement Plug-In Motor A2FE

Fixed Displacement Plug-In Motor A2FE www.phphyds.com Series 6, axial tapered piston, bent axis design for mounting in mechanical gearboxes Sizes 28...355 Nom. Pressure up to 400 bar Peak Pressure up to 450 bar he fixed displacement plug-in

More information

Fixed Displacement Motor A4FM

Fixed Displacement Motor A4FM Industrial Hydraulics Electric Drives and Controls Linear Motion and ssembly echnologies Pneumatics Service utomation Mobile Hydraulics Fixed Displacement Motor 4FM RE 91 12/4. replaces: 3.95 and RE 91

More information

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request www.atos.com Table TA60obs/E Axial piston pumps type PVPY- (-R, -) variable displacement, with mechanical controls obsolete components - availability on request PVPY are variable displacement axial piston

More information

Controllers DR, DP, FR and DFR

Controllers DR, DP, FR and DFR Controllers DR, DP, FR and DFR RE 9060 Edition: 04.014 Replaces: 10.006 For variable pump A4VSO series 1 and 3 Open circuit Features Control of pressure and flow Remote controlled optional Pressure controller

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

Axial Piston Variable Pump A10V(S)O (US-Version)

Axial Piston Variable Pump A10V(S)O (US-Version) Axial Piston Variable Pump A1V()O (U-Version) RA-A 9271/3.12 1/52 Replaces: 12.9 Data sheet eries 31 ize NG18 ((A)A1VO) ize NG28 to 14 (A1VO) Nominal pressure 4 psi (28 bar) Maximum pressure 51 psi (35

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16SK-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low noise

More information

-for information only- noncommittal. Axial Piston Variable Pump A10VSO RA / /24. Technical Data Sheet

-for information only- noncommittal. Axial Piston Variable Pump A10VSO RA / /24. Technical Data Sheet Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics ervice Axial Piston Variable Pump A10VO Technical Data heet ize 71... 180 eries 32 Nominal pressure 4000 psi (280

More information

Axial piston variable motor A10VM Plug-in version A10VE

Axial piston variable motor A10VM Plug-in version A10VE Electric Drives and Controls Hydraulics inear Motion and ssembly Technologies Pneumatics Service xial piston variable motor 10VM Plug-in version 10VE RE 91703/06.09 1/28 Replaces:09.07 Data sheet Series

More information

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar. 00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment

More information

Axial piston-variable motor A10VM Plug-in version A10VE

Axial piston-variable motor A10VM Plug-in version A10VE Electric Drives and Controls Hydraulics inear Motion and ssembly Technologies Pneumatics Service xial piston-variable motor 10VM Plug-in version 10VE R 91703/06.09 1/28 Replaces:11.07 Technical Data Sheet

More information

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries HYDRAULIC APPLICATION Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries Special vehicles Plastic and rubber machinery etc. CONTENTS Specification

More information

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC Publ. 1 - EN0709 - A 01 / 2000 / 2500 / FB Replaces : 1 - EN 084 - B L25-10709 - 1 CONTENTS GENERAL CHARACTERISTICS T67GB T6GC - T6ZC T67GB

More information

Brueninghaus Hydromatik Rexroth A11VLO pump and A11VO pump

Brueninghaus Hydromatik Rexroth A11VLO pump and A11VO pump Brueninghaus Hydromatik Rexroth A11VLO pump and A11VO pump www.hydpump.com A11VLO40, A11VLO60, A11VLO75, A11VLO95, A11VLO130, A11VLO145, A11VLO190, A11VLO260. A11VO40, A11VO60, A11VO75, A11VO95, A11VO130,

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

OMS Technical Information. Versions OMS. Versions

OMS Technical Information. Versions OMS. Versions Versions Versions Mounting flange Shaft Port size European version US version Drain connection Check valve Main type designation Standard flange Cyl. 32 G 1/2 l Yes Yes Cyl. 1.25 in 7/8-14 UNF l Yes Yes

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

OMS Technical Information Technical data

OMS Technical Information Technical data Technical data TECHNICAL DATA FOR OMS Type OMS OMS OMS OMS OMS OMS OMS OMS OMS OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSW OMSS OMSS OMSS OMSS OMSS OMSS OMSS OMSS OMSS Motor size 80 100 125 160 200 250

More information

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d R e t u r n - S u c t i o n F i l t e rs E 158 E 198 E 248 Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min 20.90-5e 0.0-2d D e s c r i p t i o n Application For operation in

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

PLD 03 T A CASAPPA S.p.A.

PLD 03 T A CASAPPA S.p.A. GEAR FLOW DIVIDERS INDEX Section Page GENERAL FEATURES... 3 GENERAL DATA... 5 FLOW EQUALIZER... 6 FLOW DIVIDERS... 8 TYPICAL CIRCUITS... 10 NOTES ABOUT COMPOSITION... 12 PORTS DIMENSIONS.... 14 GROUP DIMENSIONS...

More information

GEAR PUMPS. Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 RPM

GEAR PUMPS. Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 RPM Displacement from 5 to 39 ccm Pressure up to 280 bar Speed from 400 to 3000 PM GEA PUMPS TABE OF CONTENTS DESCIPTION......................................................................................................................

More information

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS

Displacement. from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS Displacement from 2 up to 6 sections balanced, unbalanced from 0.8 to 31 ccm FLOW DIVIDERS DP Catalogue of flow dividers DP TABLE OF CONTENTS GENERAL DESCRIPTION........................................................................................................

More information

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21

E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21 E Series Piston Pumps Variable Displacement Series for Mobile Applications Technical Catalog PVE012 PVE19 PVE21 Table of Contents Introduction......................................................................................................

More information

Orbital Motors Type OMP X and OMR X

Orbital Motors Type OMP X and OMR X Technical Information Orbital Motors Type OMP X and OMR X powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev January 218 Major revision. 21 February 217 First edition. 11 2

More information

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement Hydraulic Motor/Pump Fixed Displacement Specifications size F11-5 -6-10 -12-14 -19 Displacement [cm 3 /rev] 4.9 6.0 9.8 12.5 14.3 19.0 Operating pressure max intermittent 1) [bar] 420 420 max continuous

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL

HYDRAULIC MOTORS MTM APPLICATION OPTIONS CONTENTS EXCELLENCE GENERAL HYDRAULIC OORS APPLICAION» Skid Steer Loaders» etal working machines» renchers» Augers» Agricultural machines» Road building machines» Special vehicles» ine machines» Woodworking and sawmill machinery»

More information

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm Return Filters E 9 E E Tank top mounting Connection up to G / -6 SAE Nominal flow rate up to 5 l/min / 5.7 gpm Description Application In the return line circuits of hydraulic systems. Performance features

More information

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min Pressure Filters D D 6 In-line mounting Operating pressure up to 1 bar Nominal flow rate up to 9 l/min Description Application In the pressure circuits of hydraulic and lubrication systems. Performance

More information

DENISON HYDRAULICS T6 industrial application

DENISON HYDRAULICS T6 industrial application DENISON HYDRAULICS T6 industrial application vane pumps - single, double, triple Publ. 1 - EN0700 - B 10 / 2000 / FB Replaces : 1 - EN0700 - A L13-10700 - 2 CONTENTS - T6 SERIES INDUSTRIAL APPLICATION

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

DISC VALVE HYDRAULIC MOTORS

DISC VALVE HYDRAULIC MOTORS DISC VALVE HYDRAULIC CONTENTS Page Hydraulic otors Series S... 4 Hydraulic otors Series T... 25 Hydraulic otors Series V... 39 otor Special Features... 51 otors with Speed Sensor... 52 Application Calculation...

More information

DENISON HYDRAULICS high performance hydraulic vane pumps single, double, triple T7 and T67 industrial application

DENISON HYDRAULICS high performance hydraulic vane pumps single, double, triple T7 and T67 industrial application Back to Content DENISON HYDRAULICS high performance hydraulic vane pumps single, double, triple T7 and T67 industrial application Publ. 1 - EN 079 - B 01 / 97 / 3000 / FB Replaces : 1 - EN 079 - A CONTENTS

More information

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump Sauer Danfoss Series 90 Hydraulic Axial Piston Pump www.hydpump.com 90R030, 90R042, 90R055, 90R075, 90R100, 90R130, 90R180, 90R250 90L030, 90L042, 90L055, 90L075, 90L100, 90L130, 90L180, 90L250 Series

More information

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09. Meter out pressure compensator Sandwich plate design Type SCA... /Series X Sizes 6, 5 up to 35 bar up to 35 L/min RE 9 47/.96 RE 9 47/.96 Replaces: 9.87 Sandwich plate design Load compensation in lines

More information

HYDRAULIC MOTORS MV APPLICATION GENERAL

HYDRAULIC MOTORS MV APPLICATION GENERAL HYDRAULIC V APPLICAION» Conveyors» etal working machines» Agriculture machines» Road building machines» ining machinery» Food industries» Special vehicles» Plastic and rubber machinery etc. CONENS Specification

More information

Priority (Swing) Motors Data and Specifications

Priority (Swing) Motors Data and Specifications s Data and Specifications Specifications HMF 55 HMF 75 HMF 105 cm 3/rev in 3/rev 55 3.36 75 4.57 105 6.40 Pressure Ratings Nominal 5000 PSIG Maximum 6090 PSIG Peak 7250 PSIG Operating Speed Maximum 4100

More information

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min Return Filters E E E 6 E 6 E 7 Tank mounting Nominal flow rate up to 8 l/min Description Application In the return line circuits of hydraulic systems. Performance features Protectionagainst wear: By means

More information

Orbital Motors Type OMP, OMR and OMH. Technical Information

Orbital Motors Type OMP, OMR and OMH. Technical Information Orbital Motors Type OMP, OMR and OMH Technical Information OMP, OMR and OMH Contents Revision View Date Page Changed Revision Mar 26 Small updates B Jun 27 all Major revision with new lit-number (minus

More information

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:

More information

420 Mobile Piston Pump Design Code B

420 Mobile Piston Pump Design Code B 42 Mobile Piston Pump Design Code B ADU41 ADU49 ADU62 ADU8 Introduction 42 Series Mobile Piston Pump Eaton s 42 Series mobile pumps are open circuit, axial piston designs with displacements of 41cc, 49cc,

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min

More information

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders ENGINEERING DT PV Piston Pumps Same Day Shipments of Units or Part Orders Interchangeable Parts Fully Tested w w w. F l u i D y n e F P. c o m Email:cs@FluiDyneFP.com Contents asic characteristics.........................................................................................

More information

OMS, OMT and OMV Orbital Motors. Technical Information

OMS, OMT and OMV Orbital Motors. Technical Information , OMT and OMV Orbital Motors Technical Information , OMT and OMV A Wide Range of Orbital Motors Revision History Table of Revisions Date Page Changed Rev ED Dimensions changed EF A Wide Range of Orbital

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94 Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................

More information

OMS, OMT and OMV Orbital Motors. Technical Information

OMS, OMT and OMV Orbital Motors. Technical Information OMS, OMT and OMV Orbital Motors Technical Information OMS, OMT and OMV A Wide Range of Orbital Motors F300540.eps F300030.TIF A wide range of orbital motors Sauer-Danfoss is a world leader within production

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

MAKING MODERN LIVING POSSIBLE. Technical Information. Orbital Motor VMP. powersolutions.danfoss.com

MAKING MODERN LIVING POSSIBLE. Technical Information. Orbital Motor VMP. powersolutions.danfoss.com MAKING MODERN LIVING POSSIBLE Technical Information Orbital Motor VMP powersolutions.danfoss.com Revision History Table of Revisions Date Changed Rev Feb 214 New dimension drawings. Converted to Danfoss

More information

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min Return Filters E E Tank top mounting Connection up to G¼ ominal flow rate up to l/min Description pplication In the return line circuits of hydraulic systems. Performance features Protection against wear:

More information

220 Mobile Piston Pump Catalog Design Code A AEC028

220 Mobile Piston Pump Catalog Design Code A AEC028 220 Mobile Piston Pump Catalog Design Code A AEC028 Introduction 220 Series Piston Pump Eaton s new 220 Series piston pump signifies a step change in the generation of hydraulic power. Utilizing the latest

More information

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated Pressure reducing valve, pilot operated RE 26928/09.07 Replaces: 10.97 1/8 Type 3DR Size 16 Component series 5X Maximum operating pressure 250 bar Maximum flow 220 l/min H5844 Table of contents Content

More information

Flow divider designs MTL

Flow divider designs MTL H Y D R A U L I K Flow divider designs MTL Edition November 1999/2005 Jahns-Regulatoren GmbH D 63069 Offenbach Sprendlinger Landstraße 150 Telephon (069) 83 10 86 D 63009 Offenbach Postbox 10 09 52 Telefax

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

Orbital Motors OMS, OMT and OMV

Orbital Motors OMS, OMT and OMV MKING MODERN LIVING POSSIBLE Technical Information Orbital Motors OMS, OMT and OMV powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev February 216 Corrected Hardening specification

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

SIHI LPH-X - Liquid Ring Compressors

SIHI LPH-X - Liquid Ring Compressors - Liquid Ring Compressors LPH 50523 LPH 60527 Pressure range: Suction volume range: 0.2 to 1.5 bar 260 to 780 m³/h CONSTRUCTION Sterling SIHI liquid ring compressors are displacement compressors with a

More information

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION 2/2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32 Size 32 up to 42 MPa 700 dm 3 /min WK 490 907 04.1999r. 2/2 way cartridge valve type URZS 32 can be used to build hydraulic systems

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Variable displacement vane pump (with mechanical pressure compensator)

Variable displacement vane pump (with mechanical pressure compensator) Variable displacement vane (with mechanical pressure compensator) PVS-Type Key Features: Rotation: Right (viewed from shaft end) Mounting flanges: 4-hole flange (UNI ISO 319/2) onnections: GS SP (UNI ISO

More information

Orbital Motors OMSW with brake nose

Orbital Motors OMSW with brake nose MAKING MODERN LIVING POSSIBLE Technical Information Orbital Motors OMSW with brake nose powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev October 214 Changed to Danfoss layout

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing

More information

Industrial Hydraulic Pumps T6EDC. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement

Industrial Hydraulic Pumps T6EDC. We are doing our parts to keep you moving! Denison Vane Technology, fixed displacement Industrial Hydraulic Pumps T6EDC Denison Vane Technology, fixed displacement Hydraulic Pumps Hydraulic Motors Hydraulic Valves Hydraulic Cylinders Hydraulic Filtration Hydraulic Accumalators We are doing

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

2-way flow control valve Model 2FRM 6

2-way flow control valve Model 2FRM 6 R 28 6/0.98 Replaces R 28 62/05.94 R 28 6/06.98 2-way flow control valve Model 2FRM 6 Nominal size 6 Series X Maximum operating pressure 4569 SI (5 bar) ) Maximum flow 8.45 GM (2 L/min) H//D 585/97 + H//D

More information

Orbital Motors Type VMP. Technical Information

Orbital Motors Type VMP. Technical Information Orbital Motors Type VMP Technical Information A Wide Range of Orbital Motors Revision View Date Page Changed Revision May 213 All First edition AA F31 245 A Wide Range of Orbital Motors Sauer-Danfoss is

More information

D62 - D63 Directional Control Valve l/min

D62 - D63 Directional Control Valve l/min D62 - D63 Table of Contents 1 1.1 1.2 Product Description... 2 Function... 2 Properties... 2 2 Technical Data... 3 3 3.1 3.2 Ordering Information... 4 Type code... 4 Versions currently available... 4 4

More information

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type. Process Pump Series 3/5 Automatically Operated Type (Internal Switching Type)/Air Operated Type (External Switching Type) High abrasion resistance and low particle generation o sliding parts in wetted

More information

directional control valve series cv691

directional control valve series cv691 directional control valve series cv691 Contents Page 3 Page 4 Page 5 Page 6-7 Page 8 Page 9 Page 10 Page 11-12 General Information Technical Data Performance Curves Dimensions Relief Valve Advantages

More information

420 Mobile Piston Pump Design Code B

420 Mobile Piston Pump Design Code B 42 Mobile Piston Pump Design Code B ADU41 ADU49 ADU62 ADU8 Introduction 42 Series Mobile Piston Pump Eaton s 42 Series mobile pumps are open circuit, axial piston designs with displacements of 41cc, 49cc,

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters Suction fi lters SF 5 series Flow rate up to 8 l/min Suction fi lters FILTER SIZING The correct filter sizing have to be based on the variable pressure drop depending by the application. For example, for

More information

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1 Pressure reducing valve, direct operated, type DR 5 DP Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pressure reducing valve, direct operated, type DR 5 DP Size 5 up to 31.5MPa up to

More information

DISC VALVE HYDRAULIC MOTORS

DISC VALVE HYDRAULIC MOTORS DISC VALVE HYDRAULIC DISC VALVE 's function is to distribute fluid to the Roller Gear Set. The pressure balanced sealing surface on the valve face and the separately driven maintains minimal leakage and

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

Liquid ring compressors

Liquid ring compressors Liquid ring compressors KPH 85220, KPH 85227 Compression pressures: Suction volume flow: 2 to 7 bar 940 to 1450 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors

More information

Monoblock Directional Control Valve RMB 202

Monoblock Directional Control Valve RMB 202 Monoblock Directional Control Valve RMB 202 Key valve features RMB 202 is a 2-section mono block valve, especially designed for front-end loaders. The valve is prepared for quick connecting couplings,

More information

PRESSURE SEQUENCE VALVE TYPE UZK

PRESSURE SEQUENCE VALVE TYPE UZK PRESSURE SEQUENCE VALVE TYPE UZK Size 10, 20, 30 31,5 MPa up to 450 dm 3 /min WK 450 414 04. 2000r. Pressure sequence valves type UZK are used for switching a system or part of a system off when a set

More information

Proper Pump Installation Practices

Proper Pump Installation Practices Proper Pump Installation Practices 80-779, Rev. 10/08 There is a Reason Every Unit Comes With This Bright Orange Tag! Proper Alignment and Coupling Installation Do Not Drive Coupling Onto Shaft Pump Alignment

More information

Over-center valves type LHT with oscillation damping, zero leakage

Over-center valves type LHT with oscillation damping, zero leakage Over-center valves type LHT with oscillation damping, zero leakage Flow rate Q max = 250 lpm Operation pressure p max = 450 bar See also: o Over-center valve type LHK acc. to D 7100 o Over-center valve

More information

SDM to 8 sections monoblock valve D1WWDA02A

SDM to 8 sections monoblock valve D1WWDA02A SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information

More information

Pressure relief valve, direct operated

Pressure relief valve, direct operated Pressure relief valve, direct operated RE 570/0.05 Replaces: 06.03 /8 Type DBD..K Size Component series X Maximum operating pressure 500 bar Maximum flow 0 l/min K9- Table of contents Contents Page Features

More information

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series) Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series) Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pressure reducing valve, direct operated, sandwich

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Size

More information

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke : Hand pump type CH Product documentation Operating pressure p max : Displacement volume V max stroke : 300 bar 8.3 cm 3 /stroke D 7147 CH 04-2018-1.1 by HAWE Hydraulik SE. The reproduction and distribution

More information

Leak-Free Load-Control Valve SAE ½ psi flange

Leak-Free Load-Control Valve SAE ½ psi flange Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control

More information

PVK OPEN LOOP PUMPS. Bulletin E

PVK OPEN LOOP PUMPS. Bulletin E PVK OPEN LOOP PUMPS Bulletin 47025-E Table of Contents Performance Assurance page 3 Features and Benefits page 4-5 Specifications page 6 Pump Controls page 7 Table of Contents Curves Performance page 8

More information