CLASSE. L0E Safety Meeting. July 27, 2015

Size: px
Start display at page:

Download "CLASSE. L0E Safety Meeting. July 27, 2015"

Transcription

1 L0E Safety Meeting July 27,

2 Why are we here? ² L0E use is changing significantly We will all have to change our habits! ² To inform lab personnel most affected by the changes ² To gather feedback on possible improvements Let me know (now or anytime) of issues, suggestions, complaints that are safety-related 2

3 Radiation Safety Changes ² ERL / MLC operations will commence soon! ² Status change All of L0E will be a controlled area! Badge always required! Ø Includes DRE hallway (old opr offices, hallway to LS2) Outside door will be locked 24/7 card access only Rollup door must remain closed except when necessary to open When rollup door is open, the opener has the responsibility to closely monitor access by unauthorized personnel Badges should NOT be stored in L0E (NEXT SLIDE) 3

4 New L0E Badge Rack In hallway between stockroom and 40-ton door. You need to tell Dwight soon if you want your badge there instead of CESR control room May put dosimeters there as well Safety B.Heltsley Jul 27,

5 More Rad Safety ² Survey ( area ) badges in place will document that we keep below 100 mrad per year ² Real-time monitors will soon be in place will trip off ERL & MLC at 2 mrem/h at any probe ² Each step in operations requires a Stage Review Initial running at low power/currents is done after hours, and radiation surveys outside the perimeter are taken Committee reviews presentation by the Permit Holder (Bruce Dunham) to allow running up to a new set of Administrative Limits 5

6 First floor monitor layout EMERENCY STOP BUTTON RESET R EMERENCY STOP BUTTON L0.E EAST LIHT BEAM AIR FIRST FLOOR LEVEL EMERENCY STOP BUTTONS LIHT BEAM INTERLOCKS L0.E WEST LIHT BEAM EMERENCY STOP BUTTON EMERENCY STOP BUTTON N EMERENCY STOP BUTTON R RESET Radiation Monitors N N Neutron VACUUM LAB amma 6

7 Second Floor Monitor Layout L0.E MEZZ LIHT BEAM SECOND FLOOR LEVEL EMERENCY STOP BUTTONS LIHT BEAM INTERLOCKS EMERENCY STOP BUTTON RESET R MEZZ LADDER Radiation Monitors SECOND FLOOR LEVEL N Neutron amma N VACUUM LAB 7

8 ERL Stage Reviews 8

9 8 Stage Reviews since

10 Survey form to be filled out during any off-hours test Nine spots currently thought to be good survey points. We will explore during early surveys if slightly different spots are better choices 10

11 More Rad Safety ² We want to prevent line-of-sight radiation, especially as viewed from the 2 nd floor above the Vac Lab ² Will install shielding as necessary, either locally at MLC/ERL or along the south shielding wall Fire Safety ² We will need to assure adequate deployment of fire extinguishers inside and outside of the exclusion area 11

12 Cryogenic Safety ² The program controlling ventilation in L0E has been modified to have a minimum amount of new air at all times in order to compensate for vented liquid nitrogen. Eric Smith conducted calculations of the required rate of fresh air. ² Catastrophic releases of cryogens Requires immediate evacuation of L0E Are not expected to result in serious oxygen deficiency due to the size of L0E Will not be subtle (loud noises!) Ø 12

13 Any questions? 13

Automatic LN2 Fill Station Instructions

Automatic LN2 Fill Station Instructions Automatic LN2 Fill Station Instructions Roger Robbins 6/7/2010 Introduction: This is a step by step pictorial instruction document on how to fill a portable Liquid Nitrogen (LN2) Dewar from the Automatic

More information

Chem Bio Liquid Nitrogen Facility

Chem Bio Liquid Nitrogen Facility Chem Bio Liquid Nitrogen Facility Who: Where: When: What: How: Open to anyone working in a Western research lab that requires LN2 for their research. To become a registered user, you must attend a training

More information

Standard Operating Procedure

Standard Operating Procedure Standard Operating Procedure Use of liquid nitrogen filling station Date: 02-12-13 SOP Title: Principal Investigator: Room and Building: Lab Phone Number: Section 1 Process Use of liquid nitrogen filling

More information

Molecular Materials Research Center Beckman Institute California Institute of Technology

Molecular Materials Research Center Beckman Institute California Institute of Technology Molecular Materials Research Center Beckman Institute California Institute of Technology Long pants, and shirts that cover upper torso and upper arms are required. Safety glasses, lab coats, and gloves

More information

Cryogenic Materials Operating Procedure and Safety Requirements

Cryogenic Materials Operating Procedure and Safety Requirements VERSION 2.0 JANUARY 2, 2018 Cryogenic Materials Operating Procedure and Safety Requirements UNC CHARLOTTE 9201 UNIVERSITY CITY BLVD., CHARLOTTE, NC 28223 1 I. Overview of Liquid Nitrogen and other Cryogenic

More information

5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts.

5.1.3 Mechanical Hazards Drive assemblies have sufficient power to cause injury. Keep hands, fingers, clothing and tools clear of moving parts. Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the PE4400. All users are expected to have read and understood this document. It is

More information

Approved by BNC Managing Director Paul Lum Date: Approved by PI (s) /Super User (s): _Peter Hosemann/Andy Minor_Date:

Approved by BNC Managing Director Paul Lum Date: Approved by PI (s) /Super User (s): _Peter Hosemann/Andy Minor_Date: Approved by BNC Managing Director Paul Lum Date: Approved by PI (s) /Super User (s): _Peter Hosemann/Andy Minor_Date: Standard Operating Procedure BNC FEI Quanta 3D FEG/FIB ESEM Version 2011 Aug 30 I.

More information

Approved by Principal Investigator Date: Approved by Super User: Date:

Approved by Principal Investigator Date: Approved by Super User: Date: Approved by Principal Investigator Date: Approved by Super User: Date: Standard Operating Procedure BNC Commonwealth Dual Ion Beam Deposition System (CDIBS) Version 2010 February 14 I. Purpose This Standard

More information

Lecture Demonstrations Safety Manual & New Staff Induction

Lecture Demonstrations Safety Manual & New Staff Induction Lecture Demonstrations Safety Manual & New Staff Induction Overview The lecture demonstrations team provides and maintains demonstrations to lectures, tutorials and outreach. Demonstrations and equipment

More information

THERMAL EVAPORATION UNIT (for Al evaporation)

THERMAL EVAPORATION UNIT (for Al evaporation) THERMAL EVAPORATION UNIT (for Al evaporation) System Owner: NeerajPanwar 9619507210 panwar.iitr@gmail.com System Operator: 1. Bhimraj Sable 9930189878 bhimrajsable71@gmail.com Authorized User: 1. Ramesh

More information

Electrical Hazard Testing Procedure

Electrical Hazard Testing Procedure Note: As of this date (1/26/2005) Electrical Testing in NLCTA is prohibited. This procedure is included for historical reference only. Before allowing RASK mode activities, this procedure must be reviewed

More information

[Type here] MANAGEMENT OF X-RAY GENERATING EQUIPMENT

[Type here] MANAGEMENT OF X-RAY GENERATING EQUIPMENT MANAGEMENT OF X-RAY GENERATING EQUIPMENT HEALTH AND SAFETY UNIT AUTUMN 2016 1 CONTENTS INTRODUCTION Page 3 1. ACQUISITION OF X-RAY GENERATING EQUIPMENT Page 3 2. X-RAY EQUIPMENT FOR USE WITH HUMAN SUBJECTS

More information

DEPARTMENT OF CHEMISTY, PHYSICS AND GEOLOGY RADIATION SAFETY PLAN

DEPARTMENT OF CHEMISTY, PHYSICS AND GEOLOGY RADIATION SAFETY PLAN DEPARTMENT OF CHEMISTY, PHYSICS AND GEOLOGY RADIATION SAFETY PLAN The requirements and procedures outlined in this plan are provided in addition to the requirements outlined in the University s Radiation

More information

APPS-160 Gen 2 User Manual

APPS-160 Gen 2 User Manual APPS-160 Gen 2 User Manual Applicable Products: PN 11914406 - APPS-160 10 to 50 PSIG operating pressure PN 11918618 - APPS-160 40 to 85 PSIG operating pressure Rev 9/16/2004 Chart Ind. www-chart-ind.com

More information

Cryogenic Equipment. Accessories. Directors. Director Series Storage Vessels Specifications

Cryogenic Equipment. Accessories. Directors. Director Series Storage Vessels Specifications Accessories LN2 6 Non -Vacuum Transfer Line O2 6 Non - Vacuum Transfer Line ¼ Phase Separator LN2 Dipper Measuring Stick Small Roller Base (For use with our 10 & 20 liter tanks) Large Roller base (For

More information

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

RADIATION PROCEDURES MANUAL Procedure Cover Sheet RADIATION PROCEDURES MANUAL Procedure Cover Sheet Procedure Title: Calibration of Eberline Portable Particulate Noble Gas Monitor Procedure Number: TSO-08-13-REV 1 Effective Date: July 1, 2008 Approved

More information

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 022 MOD: 1st Issue Page: 1 of 8

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 022 MOD: 1st Issue Page: 1 of 8 THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 022 MOD: 1st Issue Page: 1 of 8 Procedure Type: General Laboratory Procedure 1. Risk Assessment:

More information

Approved by Principal Investigator Date: Approved by Super User: Date:

Approved by Principal Investigator Date: Approved by Super User: Date: Approved by Principal Investigator Date: Approved by Super User: Date: Standard Operating Procedure BNC OAI Lithographic Mask Aligner (Aligner 2) Version 2008 October 31 I. Purpose This Standard Operating

More information

Ruptured Gas Cylinder Destroys Laboratory Hood at the University of Nevada

Ruptured Gas Cylinder Destroys Laboratory Hood at the University of Nevada Ruptured Gas Cylinder Destroys Laboratory Hood at the University of Nevada The Incident: In September 2000, a steel lecture bottle located within a hood in a UNR laboratory ruptured with explosive force.

More information

Operating Procedures for Metal Evaporator I

Operating Procedures for Metal Evaporator I Operating Procedures for Metal Evaporator I Metal Evaporator I is intended as a tool and a training device. Understanding the operation of this equipment should give you a basic knowledge of vacuum and

More information

Laboratory Personal Protective Equipment & Hazard Assessment Tool

Laboratory Personal Protective Equipment & Hazard Assessment Tool Laboratory Personal Protective Equipment & Hazard Assessment Tool This form must be completed by the person in charge of the laboratory, with the guidance of the Chemical Hygiene Officer to conduct a laboratory

More information

MRI Safety Training for First Responders

MRI Safety Training for First Responders MRI Safety Training for First Responders By Sandip Basak, MD University Radiology Group 2018 Objectives Explain what an MRI is and how it works Describe the hazards of MRI Explain the safety zones of an

More information

Developing Safety Guidelines for Cryogenic Liquids.

Developing Safety Guidelines for Cryogenic Liquids. Developing Safety Guidelines for Cryogenic Liquids. Purpose: Develop a reference document that can be used by a Principle Investigator or a designee to assist in the development of Safety Operating Procedures

More information

Equipment Operating Procedure Glove Box

Equipment Operating Procedure Glove Box Equipment Operating Procedure Glove Box Page 1 0.0 Changing the Compressed Gas Cylinder 1. Complete Compressed Gas Cylinder training from EHS website before manually exchanging gas cylinders. In order

More information

0RGHO /6 /6/6/6 /LTXLGÃ/HYHOÃ(TXLYDOHQWV

0RGHO /6 /6/6/6 /LTXLGÃ/HYHOÃ(TXLYDOHQWV Operating Instructions SAFETY Before using any cryogenic refrigerator, read the Handle with Care booklet provided with the unit. It details safety precautions that must be understood before using the equipment.

More information

Standard Operating Procedure Porosity Analyzer - The Micromeritics Tri-Star II (surface area) with Micrometrics VacPrep 061 (Sample Degas System)

Standard Operating Procedure Porosity Analyzer - The Micromeritics Tri-Star II (surface area) with Micrometrics VacPrep 061 (Sample Degas System) Standard Operating Procedure Porosity Analyzer - The Micromeritics Tri-Star II (surface area) with Micrometrics VacPrep 061 (Sample Degas System) The Micromeritics Tri-Star II Surface Area and Porosity

More information

Radiation Safety Program Manual Part 3 Cyclotron - Isotope Production

Radiation Safety Program Manual Part 3 Cyclotron - Isotope Production Nova Scotia Health Authority Central Zone ISSUED: 2014-09-23 REVISED: 2017-04-13 Version 5 Radiation Safety Program Manual Part 3 Cyclotron - Isotope Production Radiation Safety Office QEII Bethune Room

More information

TEM Lab Chemical Hygiene Plan

TEM Lab Chemical Hygiene Plan TEM Lab Chemical Hygiene Plan B63 Engineering Science Building 03 Health h 40 Flammability Flammabilit y LN2 0 Reactivity y Emergency Contact: Marcela Redigolo, Ph.D. Office: G75D Engineering Sciences

More information

Usage Policies Notebook for Trion RIE / ICP Dry Etch

Usage Policies Notebook for Trion RIE / ICP Dry Etch Usage Policies Notebook for Trion RIE / ICP Dry Etch Revision date September 2014 2 Emergency Plan for Trion RIE/ICP Dry Etch Standard Operating Procedures for Emergencies Contact information Person Lab

More information

Lab Practice and Safety Guidelines

Lab Practice and Safety Guidelines RUBRIK Dokument ID Lab Practice and Safety Guidelines S-2016-0100 Fastställd av Fastställt datum Peter Unsbo 2018-04-08 Skapad av Gällande från Björn Hessmo 2018-04-08 Dokumentansvarig Version 1:e Fo.Ing.

More information

Each cryogenic liquid has its own specific properties, but most cryogenic liquids can be placed into one of three groups:

Each cryogenic liquid has its own specific properties, but most cryogenic liquids can be placed into one of three groups: 1.0 Purpose and Applicability 1.1 The purpose of this guideline is to ensure the proper management of cryogenic liquids in order to minimize exposure, accidental release, damage to equipment and injury.

More information

KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE

KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE KARL SUSS MJB3 MASK ALIGNER STANDARD OPERATING PROCEDURE Purpose of this Instrument: This instrument is for patterning photosensitive polymers with UV light. Location: White Hall 410 Cleanroom Primary

More information

A Brief Introduction to Helium Liquefaction At ITER

A Brief Introduction to Helium Liquefaction At ITER ITER Cryogenic System LHe PLANTS A Brief Introduction to Helium Liquefaction At ITER ITER Organization PLANT ENGINEERING DIVISION CRYOGENIC SECTION LHe PLANTS TRO: Eric FAUVE A Brief Introduction to to

More information

STANDARD OPERATING PROCEDURES (SOP) FOR REPRODUCTIVE HAZARDS

STANDARD OPERATING PROCEDURES (SOP) FOR REPRODUCTIVE HAZARDS STANDARD OPERATING PROCEDURES (SOP) FOR REPRODUCTIVE HAZARDS INTRODUCTION: Standard operating procedures (SOP) are intended to provide you with general guidance on how to safely work with a specific class

More information

Research Laboratory Hazard Assessment Tool For Personal Protective Equipment Use

Research Laboratory Hazard Assessment Tool For Personal Protective Equipment Use Research Laboratory Hazard Assessment Tool For Personal Protective Equipment Use The University of Iowa Date(s) 12/2018 This form is used by the PI, Lab Supervisor or their designee to accomplish two requirements

More information

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System)

Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System) Usage Policies Notebook for NanoFurnace Furnace (EasyTube 3000 System) Revision date October 2014 2 Emergency Plan for Nano Furnace Standard Operating Procedures for Emergencies Contact information Person

More information

Research Laboratory Hazard Assessment Tool For Personal Protective Equipment Use

Research Laboratory Hazard Assessment Tool For Personal Protective Equipment Use Research Laboratory Hazard Assessment Tool For Personal Protective Equipment Use The University of Iowa Date(s) 12/2018 This form is used by the PI, Lab Supervisor or their designee to accomplish two requirements

More information

Australian Standard The storage and handling of non-flammable cryogenic and refrigerated liquids SWP055

Australian Standard The storage and handling of non-flammable cryogenic and refrigerated liquids SWP055 Use this form to assist you to complete risk assessments for hazardous activities and processes. Any serious or ongoing hazards should be reported via RiskWare to ensure that appropriate corrective actions

More information

PURPOSE OF THE POLICY

PURPOSE OF THE POLICY Title: Safe Storage, Handling, Use and Disposal Procedures of Compressed Gas Cylinders Effective Date: November 2005 Revision Date: March 1, 2017 Issuing Authority: Responsible Officer: VP, Capital Projects

More information

Minnesota Rules, Chapter 4732 X-ray Revision

Minnesota Rules, Chapter 4732 X-ray Revision Minnesota Rules, Chapter 4732 X-ray Revision DRAFT X-RAY SYSTEMS FOR SUSPECTED HAZARDS, 2.0 4732.#### X-RAY SYSTEMS FOR SUSPECTED HAZARDS. Summary of Changes MDH made a number of changes to the X-Ray Systems

More information

Research Laboratory Hazard Assessment Tool For Personal Protective Equipment Use

Research Laboratory Hazard Assessment Tool For Personal Protective Equipment Use Research Laboratory Hazard Assessment Tool For Personal Protective Equipment Use The University of Iowa Date(s) 04/2016 This form is used by the PI, Lab Supervisor or their designee to accomplish two requirements

More information

Compressed Gases Safety Program

Compressed Gases Safety Program Compressed Gases Safety Program Summary: Compressed gas cylinders can present a variety of hazards due to their pressure and /or contents. This program covers requirements which must be followed for the

More information

Safety Manual > Safety Checklist for Labs

Safety Manual > Safety Checklist for Labs Safety Manual > Safety Checklist for Labs Safety Checklist For Labs Where Infectious Agents And Recombinant DNA Research Is Performed This Checklist is to be used for research labs using infectious agents

More information

Compressed Gases and Cryogens

Compressed Gases and Cryogens Compressed Gases and Cryogens University of Tennessee Safety Guide HM-011 Document Contact: EHS Date effective: January 1, 2009 Revision Date: October 1, 2015 Purpose This guideline adheres to the Occupational

More information

Georgetown Fire Department Standard Operating Guidelines

Georgetown Fire Department Standard Operating Guidelines Purpose The purpose of this guideline is to identify a course of action that will provide a systematic search and rescue process for a lost or trapped firefighter. I. Introduction A. Rescue of lost or

More information

Approved by Principal Investigator Date: Approved by Super User: Date:

Approved by Principal Investigator Date: Approved by Super User: Date: Approved by Principal Investigator Date: Approved by Super User: Date: Standard Operating Procedure BNC OAI 200 Lithographic Mask Aligner (Aligner 3) Version 2011 June 2 I. Purpose This Standard Operating

More information

Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No

Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System. Dwg. No Rev. ECO Description Checked Approval Date 01 32- Release M. Smith Vacuum Pumpdown and Venting Procedure, CRaTER Thermal Vacuum System Dwg. No. 32-06003.05 Revision 01 June 18, 2007 1 1. Introduction 1.1.

More information

Magnet Safety Plan. Revised: September 2015 Office of Environmental Health and Safety University of New Hampshire. All rights reserved.

Magnet Safety Plan. Revised: September 2015 Office of Environmental Health and Safety University of New Hampshire. All rights reserved. Magnet Safety Plan Revised: September 2015 Office of Environmental Health and Safety 2015 University of New Hampshire. All rights reserved. The most current version of this document can be found at: http://www.unh.edu/research/magnet-safety-0

More information

R I T. Title: Amray 1830 SEM Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 09/29/03 1 SCOPE 2 REFERENCE DOCUMENTS

R I T. Title: Amray 1830 SEM Semiconductor & Microsystems Fabrication Laboratory Revision: A Rev Date: 09/29/03 1 SCOPE 2 REFERENCE DOCUMENTS Fabrication Laboratory Revision: A Rev Date: 09/29/03 Approved by: Process Engineer / / / / Equipment Engineer 1 SCOPE The purpose of this document is to detail the use of the Amray 1830 SEM. All users

More information

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530) http://safetyservices.ucdavis.edu Laboratory Safety Review Checklist One Shields Ave Davis, CA 95616 Phone: (530)752-1493 Fax: (530)752-4527 E-mail: researchsafety@ucdavis.edu U C Davis Environmental Health

More information

Title: Non-Destructive Inspection

Title: Non-Destructive Inspection Environmental Standard Operating Procedure Originating Office: Revision: Original Prepared By: Approved By: MCAS Miramar Environmental Management Department Environmental Management Department William

More information

LENS Radiation Safety Manual

LENS Radiation Safety Manual 1 LENS Radiation Safety Manual Approval Organization Title Name Signature Date MESH LENS Radiation Safety Officer Greg Crouch 12-06-17 Revision History (most recent first) Revision Effective Date Purpose

More information

Usage Policies Notebook for Parylene Coating System

Usage Policies Notebook for Parylene Coating System Usage Policies Notebook for Parylene Coating System Revision date September 2014 2 Emergency Plan for Parylene Coating System Standard Operating Procedures for Emergencies Contact information Person Lab

More information

"CONFINED SPACE ENTRY"

CONFINED SPACE ENTRY PRESENTER'S GUIDE "CONFINED SPACE ENTRY" Training for the OSHA HAZARDOUS WASTE OPERATIONS and EMERGENCY RESPONSE (HAZWOPER) REGULATION Quality Safety and Health Products, for Today... and Tomorrow OUTLINE

More information

Status and Outlook. Fraser Duncan Queen's University. Majorana Collaboration Meeting June 2005

Status and Outlook. Fraser Duncan Queen's University. Majorana Collaboration Meeting June 2005 Status and Outlook Fraser Duncan Queen's University Majorana Collaboration Meeting 20 21 June 2005 SNOLAB Science Objectives Particle Astrophysics: Low energy solar neutrinos Search for dark matter Search

More information

Warnings: Notes: Revised: October 5, 2015

Warnings: Notes: Revised: October 5, 2015 Karl Suss MA6 Mask Aligner Standard Operating Procedure Faculty Supervisor: Prof. Robert White, Mechanical Engineering (x72210) Safety Office: Peter Nowak x73246 (Just dial this directly on any campus

More information

DD2 Site Preparation Checklist Hardware Site Preparation Specification

DD2 Site Preparation Checklist Hardware Site Preparation Specification Thank you for purchasing an Agilent instrument. To get you started and to assure a successful and timely installation, please refer to this specification or set of requirements. Correct site preparation

More information

Western Sydney University Safety Inspection Checklist - Laboratory Environments

Western Sydney University Safety Inspection Checklist - Laboratory Environments Western Sydney University Safety Inspection Checklist - Laboratory Environments Useful Hint: To maximise the benefits that can be gained from a workplace inspection activity read the Western Sydney University

More information

ALiCE. Keeping Safe at Chartiers Valley Intermediate School

ALiCE. Keeping Safe at Chartiers Valley Intermediate School ALiCE Keeping Safe at Chartiers Valley Intermediate School ALiCE The adults in your building care about you and your safety. With the help of ALiCE, we can keep you safe. ALiCE Alert Lockdown Inform Counter

More information

Health & Safety Policy and Procedures Manual SECTION 38 RADIATION SAFETY PROGRAM

Health & Safety Policy and Procedures Manual SECTION 38 RADIATION SAFETY PROGRAM SECTION 38 RADIATION SAFETY PROGRAM 1. GENERAL REQUIREMENTS 1. Maul Electric, Inc radiation safety program along with 29CFR 1910.1096 and 10CFR 20.1101 include provisions for project sites to keep radiation

More information

Laboratory Start-Up Procedure

Laboratory Start-Up Procedure Laboratory Start-Up Procedure 1. Purpose and Scope 1.1. The purpose of this procedure is to help faculty establish a safe and compliant laboratory environment. 2. Responsibilities 2.1. Department Head

More information

LEO 1525 FEG SEM Standard Operating Procedures Mar. 6, 2012 For additional assistance, please contact the facility manager.

LEO 1525 FEG SEM Standard Operating Procedures Mar. 6, 2012 For additional assistance, please contact the facility manager. LEO 1525 FEG SEM Standard Operating Procedures Mar. 6, 2012 For additional assistance, please contact the facility manager. Please contact in case of emergency: SEM microscopist: Mr. Eric Miller, 7-0789

More information

HEALTH AND SAFETY SERVICES

HEALTH AND SAFETY SERVICES . HEALTH AND SAFETY SERVICES WELLBEING, SAFETY AND HEALTH LOCAL RULES FOR THE USE OF X-RAY EQUIPMENT??FACULTY??? /??FACILITY?? DOCUMENT CONTROL These local rules should be reviewed annually. Date Signed

More information

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530)

Laboratory Safety Review Checklist One Shields Ave Davis, CA Phone: (530) Fax: (530) http://safetyservices.ucdavis.edu Laboratory Safety Review Checklist One Shields Ave Davis, CA 95616 Phone: (530)752-1493 Fax: (530)752-4527 E-mail: ehsdesk@ucdavis.edu U C Davis Environmental Health and

More information

METHODS TO PREVENT THE PREMATURE ACTIVATION OF RELIEF DEVICES ON TRANSPORT TANKS

METHODS TO PREVENT THE PREMATURE ACTIVATION OF RELIEF DEVICES ON TRANSPORT TANKS METHODS TO PREVENT THE PREMATURE ACTIVATION OF RELIEF DEVICES ON TRANSPORT TANKS IGC Doc 184/14/E EUROPEAN INDUSTRIAL GASES ASSOCIATION AISBL AVENUE DES ARTS 3-5 B 1210 BRUSSELS Tel: +32 2 217 70 98 Fax:

More information

Standard Operating Procedure. For. PVD E-Beam

Standard Operating Procedure. For. PVD E-Beam P a g e 1 Standard Operating Procedure For PVD E-Beam P a g e 2 Introduction The PVD Electron-Beam Evaporator (E-Beam) thin film deposition machine uses a magnetically guided and collimated stream of electrons

More information

Procedure for Filling 2 T Bruker Magnet with Nitrogen

Procedure for Filling 2 T Bruker Magnet with Nitrogen Procedure for Filling 2 T Bruker Magnet with Nitrogen Note: Nitrogen fills require 2 people to be present. Transfer of N2 from Reservoir to Dewar 1) Get keys from Phil s desk and open door to courtyard.

More information

Login to ilab Kiosk. Revised 05/22/2018. Load your sample:

Login to ilab Kiosk. Revised 05/22/2018. Load your sample: Login to ilab Kiosk Load your sample: 1. Check: The analysis chamber pressure is

More information

PRad Target. Chris Keith JLab Target Group

PRad Target. Chris Keith JLab Target Group PRad Target Chris Keith JLab Target Group Target Overview & Components Target Software Hazard Analysis and Mitigation Target Status, Performance& Remaining Work Installation Schedule Nov. 12, 2015 PRad

More information

Virtual Pipeline Emergency Response Guide

Virtual Pipeline Emergency Response Guide Virtual Pipeline Emergency Response Guide Revised 7/24/17 Rev A Preface The intent of this guide is to provide information to help you respond to emergency situations involving Quantum VP Trailers in

More information

Revised: June 7, 2017

Revised: June 7, 2017 LC Technologies Thermal Evaporator Standard Operating Procedure Faculty Supervisor: Prof. Robert White, Mechanical Engineering (x72210) Safety Office: Peter Nowak x73246 (Just dial this directly on any

More information

EHS Laboratory Guidance: Cryogenic Material

EHS Laboratory Guidance: Cryogenic Material EHS Laboratory Guidance Cryogenic Liquids 1 Introduction/Purpose Cryogenic liquid is defined by the Idaho Fire Code as having a boiling point of less than -90º C (-130º F) at 14.7 psia (1 bar). All cryogenic

More information

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases.

Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases. CRYOGENICS SAFETY Introduction Cryogenics is the science of ultra low temperatures. Low temperatures are achieved by the liquefaction of gases. The gases which are most widely used in industry and research

More information

Laboratory Safety Inspection Checklist

Laboratory Safety Inspection Checklist Conducted By: Date of Inspection: Location: Safety and Risk Management Office Laboratory Safety Inspection Checklist Principal Investigator/Supervisor: General Lab Housekeeping A M S NO NA Comments Laboratory

More information

Faculty/School: Psychology Initial Issue Date: 27/08/2015 Next Review Date: 27/08/2017 Risk Assessment Reference Number: LCMS_0001.

Faculty/School: Psychology Initial Issue Date: 27/08/2015 Next Review Date: 27/08/2017 Risk Assessment Reference Number: LCMS_0001. Use this form to assist you to complete risk assessments for hazardous activities and processes. Any serious or ongoing hazards should be reported via RiskWare to ensure that appropriate corrective actions

More information

Working with Cryogenic Liquids

Working with Cryogenic Liquids Standard Operating Procedure (SOP) Working with Cryogenic Liquids BUILDING: PREPARED BY: ROOM: REVISION DATE: Experimental Process Brief Description of the Operation/Experiment: Specialized Training Instructions:

More information

University of Aberdeen

University of Aberdeen University of Aberdeen Ionising Radiation Safety Arrangements APPENDIX 9 X-ray Equipment form Version 1 May 2017 Authorised by Radiation Hazards Sub Committee Appendix 9 Version1 X-Ray form Page 1 of 5

More information

SCOPE OF WORK, SAFETY METHOD STATEMENT & RISK ASSESSMENT

SCOPE OF WORK, SAFETY METHOD STATEMENT & RISK ASSESSMENT SCOPE OF WORK, SAFETY METHOD STATEMENT & RISK ASSESSMENT Prepared for:- Date:- Work Scheduled:- SCOPE OF WORK Carry out installation of flow meters / pressure sensors. Installation of flow meter procedure

More information

Compressed Gases STANDARD OPERATING PROCEDURE

Compressed Gases STANDARD OPERATING PROCEDURE Compressed Gases STANDARD OPERATING PROCEDURE Type of SOP: Process Hazardous Chemical Hazard Class 1. HAZARD OVERVIEW This document describes the safety requirements that laboratory workers and supervisors

More information

Plasma Asher: March PX-500 User guide (May-30, 2017)

Plasma Asher: March PX-500 User guide (May-30, 2017) Plasma Asher: March PX-500 User guide (May-30, 2017) This is a highly versatile plasma etch tool that can etch using a direct plasma configuration (Oxygen plasma cleaner), a downstream plasma (Remote plasma),

More information

Laboratory Safety. ALARA Practices Attire Hazards Electricity Radiation Fire Signage Emergency response

Laboratory Safety. ALARA Practices Attire Hazards Electricity Radiation Fire Signage Emergency response Laboratory Safety ALARA Practices Attire Hazards Electricity Radiation Fire Signage Emergency response Safety Is Everyone's Top Priority Use common sense, think, learn, and pay attention ALARA As Low As

More information

University of New Haven DEPARTMENT OF CHEMISTRY and CHEMICAL ENGINEERING

University of New Haven DEPARTMENT OF CHEMISTRY and CHEMICAL ENGINEERING University of New Haven DEPARTMENT OF CHEMISTRY and CHEMICAL ENGINEERING A. Instructions: Student: Read carefully the following laboratory rules, safety precaution, and regulations. Your laboratory conduct

More information

Oxygen Deficiency Hazard Safety Booklet

Oxygen Deficiency Hazard Safety Booklet Oxygen Deficiency Hazard Safety Booklet Central Helium Liquefier Complex Last Revision: July 2008 Many work areas at Jefferson Lab store or use compressed gasses, liquefied gasses, and volatile liquids.

More information

Reducing Exposures From Confined Space Entry

Reducing Exposures From Confined Space Entry Reducing Exposures From Confined Space Entry Over 1.6 million Americans work in Confined Spaces each year, and each year many accidents occur. Many of these accidents lead to serious injury or death from

More information

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd.

Short Introduction to Cryo-Pumps and Refrigerators. Dr Graham Rogers Leybold UK Ltd. Short Introduction to Cryo-Pumps and Refrigerators Dr Graham Rogers Leybold UK Ltd. Cryo Pumps Topics Physical principles of cryo-pumping Design and control of modern refrigerator cryo-pumps UHV and XHV

More information

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel TANK MANAGER FOR TWO TANKS OPERATING MANUAL 10/31/11 C-More T6C L color touch panel 1 TABLE OF CONTENTS GENERAL...3 INSTALLATION...4 STONE TEST PROCEDURE...7 OPERATIONAL SUMMARY...7 AUTO CARBONATION...10

More information

UTMB RESPIRATORY CARE SERVICES GUIDELINES Respiratory Care Services Medical Gas Cylinder Storage, Use and Transport

UTMB RESPIRATORY CARE SERVICES GUIDELINES Respiratory Care Services Medical Gas Cylinder Storage, Use and Transport Page 1 of 4 I. Title Medical Gas. II. III. IV. Policy This policy applies to all departments and areas where medical gases are used, stored or transported for patient care activities. Respiratory Care

More information

SLAC AREA HAZARD ANALYSIS

SLAC AREA HAZARD ANALYSIS SLAC AREA HAZARD ANALYSIS Location(s): IR-2 and immediate support buildings & seatrains (B620, B620A, B624, B625, B628, B629, B632) Date: 30 May 04 Processes / Equipment in Area Hazards Recommended Controls

More information

Laboratory Preparedness Checklists for Advanced Planning, Preparing to Close & Safe Re-Entry

Laboratory Preparedness Checklists for Advanced Planning, Preparing to Close & Safe Re-Entry Laboratory Preparedness Checklists for Advanced Planning, Preparing to Close & Safe Re-Entry Disruptions, utility outages, and severe weather events may require a laboratory closure. These events have

More information

CONFINED SPACES. Procedures for Permit-required ALTERNATIVE TO A FULL PERMIT ENTRY. Written Programs

CONFINED SPACES. Procedures for Permit-required ALTERNATIVE TO A FULL PERMIT ENTRY. Written Programs THEME nº17: RESPONSIBLE: Confined Spaces (OSHA) Werson Monteiro ALTERNATIVE TO A FULL PERMIT ENTRY Under certain conditions described in the stard, the employer may use alternate procedures for worker

More information

CARS Environment, Safety and Health Plan

CARS Environment, Safety and Health Plan CARS Environment, Safety and Health Plan Version 5/11/11 P. James Viccaro, CARS Director [Signature] [Date] 1 CARS Environment, Safety and Health Plan Table of Contents Section 1 CARS Safety Policies...

More information

LEO SEM SOP Page 1 of 9 Revision 1.4 LEO 440 SEM SOP. Leica Leo Stereoscan 440i

LEO SEM SOP Page 1 of 9 Revision 1.4 LEO 440 SEM SOP. Leica Leo Stereoscan 440i LEO SEM SOP Page 1 of 9 LEO 440 SEM SOP Gun (Filament) Column Manual Valves Chamber Window Chamber Stage Movement Leica Leo Stereoscan 440i 1. Scope 1.1 This document provides the procedure for operating

More information

Justification and use of hand-held X-ray equipment

Justification and use of hand-held X-ray equipment HERCA Statement Justification and use of hand-held X-ray equipment This document was approved by the Board of HERCA on 31 Index 1. Radiation hazards 3 2. Regulatory requirements 4 3. Recommendations 4

More information

This symbol denotes what could lead to serious injury or death if you misuse the PAR-F27MEA. WARNING CAUTION

This symbol denotes what could lead to serious injury or death if you misuse the PAR-F27MEA. WARNING CAUTION GB WT0407X0 CITY MULTI Control System ME Remote Controller PAR-F7MEA Instruction Book Thank you for purchasing a Mitsubishi CITY MULTI system. To use your CITY MULTI system correctly and safely, please

More information

Virtual Pipeline Emergency Response Guide

Virtual Pipeline Emergency Response Guide Virtual Pipeline Emergency Response Guide Use in conjunction with ERG 2016 Guide 115 Revised: November 2018 Rev C Preface The intent of this guide is to provide information to help you respond to emergency

More information

2. The purpose of this program is to achieve the following objectives:

2. The purpose of this program is to achieve the following objectives: Section 16A. Lockout and Tagout Program 1. In the course of their duties, personnel at the TFREC may need to secure controls, switches, and equipment in order to prevent injury caused by the sudden, unexpected

More information

Safe Handling of Pressurized Gases and Cylinders. Dr. Michael Hanisch

Safe Handling of Pressurized Gases and Cylinders. Dr. Michael Hanisch Safe Handling of Pressurized Gases and Cylinders Dr. Michael Hanisch Pressurized Gases Safety - Introduction Even a wall will not stop me! Pressurized Gases Safety - Introduction Objectives Protection

More information

Faculty/School: Pharmacy Initial Issue Date: Oct 2016

Faculty/School: Pharmacy Initial Issue Date: Oct 2016 Use this form to assist you to complete risk assessments for hazardous activities and processes. Any serious or ongoing hazards should be reported via RiskWare to ensure that appropriate corrective actions

More information

OSHA FIRE INVESTIGATOR OPERATIONS SAFETY CHECKLISTS GENERAL SCENE SAFETY PROCEDURES

OSHA FIRE INVESTIGATOR OPERATIONS SAFETY CHECKLISTS GENERAL SCENE SAFETY PROCEDURES OSHA FIRE INVESTIGATOR OPERATIONS SAFETY CHECKLISTS These checklists are provided as examples and are by no means all-inclusive. Fire service and law enforcement agencies should review them and add or

More information

Laboratory Safety Manual Prepared by RAEIN-Africa & Partners. Under the Implementation of The National Biosafety Framework Project for Swaziland

Laboratory Safety Manual Prepared by RAEIN-Africa & Partners. Under the Implementation of The National Biosafety Framework Project for Swaziland Laboratory Safety Manual Prepared by RAEIN-Africa & Partners Under the Implementation of The National Biosafety Framework Project for Swaziland Contents Preamble/ Introduction... 2 Safety declaration...