1 CAT Course Trust Your Water
2 Introduction Kinetico features and softened water benefits Cocurrent and countercurrent regeneration Check the correct installation Field Analysis Installation instructions Data sheet Reading Brine valve adjustment Replacing of metric disk Optionals (Bioclormatic 5, By-pass) First start operations Valve control system Mach valve control system AccuDial valve control system Maintenance 10 steps to find the problem - Troubleshooting
3 INTRODUCTION
4 Kinetico Features No power supply Operating on demand Double column system (duplex) Low consuption of salt Quick countercurrent regeneration Softened water during the regeration
5 Softened water benefits Reduction of detergents and soaps costs Better performance of washing machines and dishwashers Skin and hair more soft and healthy Longevity of the appliances, and reduction of maintenance Saving electricity and CO2 emission It keeps everything cleaner, removing stains and spots
6 Softened water - choosing the correct salt The salt for the regeneration of the resin is dissolved in softened water. When reached "100% saturation salt forms the brine. Use special water softening salt, superior quality, in tablets. Do not use granular salt.
7 Cocurrent Regeneration Service Salamoia The regeneration flow pushes the exhausted ions through the resin bed. This requires a strong dose of brine to obtain a complete regeneration of the entire resin bed.
8 Service Countercurrent Regeneration Brine The regeneration stream is much more efficient and keeps the always clean resin bed for better regeneration efficiency.
9 Duplex systems operation Alternate Overdrive
10 Finding a suitable system Denomination Kinetico product denomination s OD Abbreviation = OD = Overdrive HF = High flow HE = High efficiency 1 figure= Cylinders number Type: S = Softener F = Column Filter C = Cabin Cruiser Maximum hardness Capacity in grams per liter (0.96 x = dh)
11 CHECK THE CORRECT INSTALLATION
12 Field Analysis Check the water quality input (raw) Check the inlet pressure Check the correct installation
13 Calculation of the compensated hardness Hardness in mg / l + (51 x Iron in mg / l) = hardness compensated For example, for water at 30 f and with 0.5 mg/l of Iron is: Hardness offset = (51 x 0.5) = mg/l = f
14 Installation instructions Connect the softener to the system by means of flexible pipes. Avoid using rigid pipes that can transmit stress to the valve, with the risk of breakage of the plastic fittings or in the worst case damage to the same valve Provide a desander filter before the device The technique UNI 9182 in paragraph 15 prescribes an anti water hammer upstream of each plant. It therefore recommended the installation Provide a System by-pass, made with the classic three ball valves, for any servicing and to perform a mixing of the hardness. The water that passes through the bed of resin is softened to zero French degrees (0 f).
15 Installation instructions Provide upstream and downstream of the softening the stop valves for opening / closing of the water flow and, always both upstream and downstream of the system, provide for water draw-off taps for a check on the state of operation of the product Connect the apparatus to a suitable drain. The output water from softener is slightly under pressure. Do not exceed a vertical height of the discharge of 1.80 m (with incoming water pressure equal to 3 bar) Pressurize the system with all water connections completed. Check for any leaks from the installed fittings. Maintain closed the valve downstream of the softener, to avoid that the preservative contained within the resin can flow to the water system (it should be noted that it is in any case a food product) For any problems that may arise during installation or a request for the first start of the softener, contact the Technical Department
16 Reading the data sheet Each sheet contains technical data certified and tested for each unit Contains the work produced limits Table for the disk selection according to the type of unit Reading the data sheet
17 Brine valve adjustment 196 mm Regeneration Specifications Volume of water regeneration...26,5 litri Regeneration time...11 minuti Flow rinse...5,3 lpm Flow rinse of brine tank...1,5 lpm Disk Selection (Compensated hardness *)
18 Metric Disk Replacement Unscrew the lid of the protective cover from the control head (hex screws SW AF 1/4 "- Fig. 1). Remove the plastic poppet (actuator) with its O-ring and the spring (Fig.2). Replace the metric disk. Be careful that the disc is removed with caution and that the other control device bodies remain in their position. When introducing the new metric disk, move outwards, with the help of a screwdriver, the feed arm (v. Fig. 3). Refit the spring, the actuator with its o-ring and the protective cover. IMPORTANT: positioning the cover in correspondence with 5 o clock, to ensure that it is positioned in the correct manner (Fig.1).
19 Protective Cover 5 o clock position Programmer Disk Piston O-ring actuator Actuator O-ring Spring Piston Spring Advancer arm Tooth sealing
20 Remove the cover screws Remove the cover and the actuator Remove the Hard Metric currently in use Be careful not to remove the arms Enter the new Disk Metric Turn the disc gently clockwise until the pawls fall into their position Replace Actuator and lid, taking care that the o-ring is in correct location Tighten the screws of the cover crosswise
21 Phase Indicator Central Adjustment Screw
22 Optional accompanying the softener By-pass with 3/4 "and incorporated mixing valve (cod ). Operating temperature up to 50 C (Note: only available for Ergo models, Sumo, Mach 2025s, Mini Enki, Mach 2050s, CC series); Hardness kit to control the level of calcium and magnesium in water (cod. ETK0008); Bioclormatic 5, electrolytic manufacturer of chlorine with battery operation (cod. BIOCL5); IMPORTANT: installed upstream of the softener a suitable protective filter.
23 Regolation by-pass 3/4 Using silicone grease and O-ring supplied before installing the bypass water softener. The metal clip serves to maintain the hooked by-pass the softener: for fixing use the metal pin supplied. Connect the hoses in the correct way, following the arrows imprinted on the valve and the bypass. Regulate mixing screw Completely opened Completely closed
24 It is recommended that during the start-up phase to maintain the fully closed mixing valve. Then carry out the mixing in the following, in order to obtain a "tail" of residual hardness In place of the by-pass, if you ordered the softener with normal plastic pipe unions 3/4 "BSP, install them after greasing of the o-ring seal and secure them always with the same metal clip supplied By-pass Valve Pin with head Stirrup In/Out Sealing Rings
25 First start-up operations When the setting and adjustment phase is complete, the softener is ready to start. First, it is advisable to put in pressure the system, checking that there are no leaks from the fittings and the pipe unions. Then slowly open the gate valve upstream of the water softener and keep that in valley closed. After waiting a few minutes for the softener to finally be pressurized with a star screwdriver, push on the central adjusting screw and rotate slowly clockwise until the actuator has advanced the cursor (phase indicator) to the " Brine / Rinse " position (suction brine / slow rinse). You should hear four or five "clicks" as you turn the screw. At this point you should also feel the water flowing towards the drain. After waiting for about 5 minutes, the suction and slow rinsing phase can be accelerated (only at first start), always turning the central adjusting screw clockwise, thus advancing the phase black indicator.
26 First start-up operations It is recommended to rest another 5 minutes on the penultimate stage (rinsing energetically) to be sure you eliminate well all trace of preservative(it is anyway a food product). The last step is to fill the brine with the water. This step can be skipped. The indicator is now in "12 o'clock" or "6 o'clock" position (imagine the phase indicator disc as a clock). The softener is in service, no drain water is noticeable and a cylinder has been regenerated / rinsed. At this point do the same operations for the second cylinder. IMPORTANT: The filling phase of the tin in this case should not be skipped. It is necessary to make it completely, because by doing so, the softener puts in the shaker the water necessary to dissolve the salt.
27 First start-up operations After returning to the service stage (no drainage softener, set at "12 o'clock" or "6 o'clock, both rinse / regenerated cylinders), slowly open the shut off valve downstream of the water softener. By carrying out a hardness test in the water softener valley, it should have water at zero degrees Fahrenheit. By using the bypass pipe, mix the required / desired water.
28 THE CONTROL VALVE SYSTEMVALVOLE
29 Regeneration arm Tooth sealing Progress Arm
30 Metric Disc #1 Metric Disc # 5
31 Differences between Metric Disk and Control Disk White C/D (Control Disk) Tan C/D (Control Disk) 31
32 Regeneration arm Progress arm
33 Metric Disk, Control Disk and Bracket In the upper part of the valve is located on the Disk Metric that allows the regeneration. Disco Metrico
34 Metric Disk, Control Disk and Bracket Meter disk level 1
35 Metric Disk, Control Disk and Bracket Metric Disk Progress Arm
36 After a certain volume of water, the Metric Disk and the Control Disk proceed in the same direction, the fourth shutter opens the piston which allows the discharge of water used for regeneration. Metric Disk Control Disk Control Disk
37 Metric Disk, Control Disk and Bracket The arm starts regeneration Tooth regeneration management
38 Start regeneration Metric Disk, Control Disk and Bracket
39 Two types of valves available for TYW water softeners: - Standard Valve (Mach 1000) Kinetico Valve - High Performance Valve (Mach 1250)
40 Mach Valve
41 Mach Valve Regeneration chamber Flow control Exit chamber
42 Mach Valve Movement Trasmission The turbine accounts for the amount of water coming out dall'addolcitore treated. The movement of the gears Weighted transmits the movement to the control disc and subsequently to debimetrico disc.
43 Valve Body
44 Valve Body
45 Valve Body
46 Valve Body
47 Valve Body
48 Valve Body
49 Sumo/Ergo Valve
50 Sumo/Ergo Valve AccuDial Venturi System 1/2 Discharge 3/8 brine valve connection Input Output
51 AccuDial Sumo/Ergo Valve
52 Sumo/Ergo Valve Level 1+2 Level one is made up of four chambers: inlet, outlet, regeneration and by-pass. The hard water enters the inlet chamber and immediately goes into contact with the resins. Contained in the outlet chamber there is a turbine that measure the required water flow. The regeneration chamber is an independent chamber, which is used during the regeneration process. The room by-pass is located between the inlet and outlet chambers. During the regeneration process, the chamber of the by-pass is open, supplying raw water to the user.
53 Level 3 Venturi Sumo/Ergo Valve Level 3 interfaces with the level 1 because it transmits pressure signals. It also contains vital components such as the control of the regeneration flow, the nozzle of regeneration, regeneration control valve and the venturi. By-pass Valve Regeneration Control Valve Discharge
54 Sumo/Ergo Valve Level 4 Here there are four operating valves: inlet / by-pass, output, control valve, brine flow controller and its check valve. Brine Control Valve Venturi Controller brine stream Input/by-pass valve Control Valve Release valve Discharge controlling Exhaust valve
55 Sumo/Ergo Valve Level 5 This level creates a surface for the proper operation of valves contained in the layer 4. It also includes the graft for the suction of the brine. Brine extraction
56 Sumo/Ergo Valve Level 6 The last level of the valve is used to direct the flow of water in the tank during normal operation. The flow during normal operation is upflow (cocurrent). The regeneration takes place in counter-current (downflow).
57 MAINTENANCE
58 Routine maintenance operations To ensure good drainage performance, lost taps, toilets, or damaged pipes, must be repaired. Keep the pre-filter upstream of the water softener clean (especially if manual self-cleaning). The filter cartridge should be replaced periodically, especially when the water pressure begins to decrease progressively. The life of the cartridge depends on your water consumption and the specific features of your water. Make sure you never miss salt inside the can. Add salt before the water level is visible in the kettle. Use high quality salt, in pastillas, specific for softeners, pressurized and not glued. Some salts contain impurities that can cause problems to your water softener. Always choose a quality salt product specifically for water softeners. DO NOT USE KITCHEN SALES, which generally contains too much impurities and foreign substances. If the salt level is poor or absent, the water softener can not function properly. Keep the interior of the cabin cruiser clean from any sediment or dirt that can be created inside with the passage of time. If necessary clean with only cold water, without the addition of any chemicals (eg detergents or chlorine derivatives). If dirt is formed frequently, change the type of salt. If BIOCLORMATIC is installed, check battery activity status every 6 months. If the LED does not blink, replace the batteries.
59 Maintenance operations Troubleshooting Mach series Troubleshooting Ergo/Sumo series 10 steps to find the problem!
60 Thanks for watching
DRS4-RM Manual. Set Up Instructions for DRS4 Series Single Tank
Set Up Instructions for DRS4 Series Single Tank Inspect the packaging of the equipment to confirm that nothing was damaged during shipping. (Figure 1) Remove the resin tank(s) and valve(s) from the packaging.
More informationThe ultimate in water softening
Calming troubled waters Metered Water Softener Specification MODEL: CALSOFT M The ultimate in water softening Due to Calmag s commitment to new product development the photographs contained within these
More informationNORMAL OPERATING DISPLAYS GENERAL OPERATION
SunTapWat e rsys t e ms WS1Cl ac kwat e rsof t ne r Owne r smanual MAIN COMPONENTS Your water treatment system is a point of entry (POE) system composed of three components: A. The control valve and computer
More informationInstallation and Instructions 2. Product Features 3-6. Key Pad Functions 7. Distributor Information Programming Guide 8. Master Programming Guide 9-14
Installation and Instructions 2 Product Features 3-6 Key Pad Functions 7 Distributor Information Programming Guide 8 Master Programming Guide 9-14 Dimensional Drawing 15 D-STC & D-SMM Valve Assembly 16-17
More informationDuplex Commercial Softeners
Duplex Commercial Softeners Installation, Operation & Maintenance Guide Manual 003.1 Contents Page 1. Unpacking Instructions 3 2. Installation 4 Pre-installation checks Fitting the bottom distribution
More informationUser's Manual. MixRite TF 10. Edition 05.08
User's Manual MixRite TF 10 Edition 05.08 1 Tefen MixRite TF 10 fertilizer and chemicals Injector Congratulations on your purchase of one of Tefen s high quality products. To get the best results from
More informationRegulators repair and maintenance. 1st stage MC5. MC5 INT HZ MC5 DIN 300 bar HZ
1st stage MC5 MC5 INT HZ 800098 MC5 DIN 300 bar HZ 800099 January 2008 Rev. MC5 / 1 Ed. A / 08 1 1st stage MC5 WARNING! This document is intended for experienced technical personnel who have already attended
More informationEasy Nest Kits. Installation Suggestions
Easy Nest Kits Installation Suggestions 2 General Recommendations Hydraulics Vacuum breakers should be installed to prevent siphoning. Flexible connectors should follow FRP tank manufacturers recommendations.
More informationCommercial Softeners. Installation, Operation & Maintenance Guide. Manual 002.1
Commercial Softeners Installation, Operation & Maintenance Guide Manual 002.1 Contents Page 1. Unpacking Instructions 3 2. Installation 3 Pre-installation checks Fitting the bottom distribution system
More informationService and Repair Manual
II stage R2 Ice/ Special, II stage R 1 Pro DOWNSTREAM 2 nd STAGE REGULATOR Service and Repair Manual Introduction Safety Precautions...4 General Procedures, Maintenance Schedules...5 Initial Inspection
More informationOperation Manual. Carbon Filtration Industrial Drive, Orlinda, TN fax
Operation Manual Carbon Filtration 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2 Theory of Operation... 2 1.3 System Illustration...
More informationPerforma Cv Twin Alternating and High Flow Systems. Manual Supplement
Performa Cv Twin Alternating and High Flow Systems Manual Supplement Table of Contents 1.0 Installation and Start-Up.............. 3 Water Line Connection Brine Tank Turbine Connection Connecting Manifold
More informationFilling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series
Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series Main features Designed for automatic filling of sealed heating systems and for protection of the water mains from risk of contamination.
More informationAutotrol Performa ProSoft
Autotrol Performa ProSoft With 960 Series Control 5-Cycle Conditioner 5-Cycle FA Filter Water Conditioning Control System Installation, Operation and Maintenance Manual Table of Contents Installation.....................................
More informationVB85/ Pressure regulating valve (Unloader)
Ultimo aggiornamento: 20/09/12 VB85/160 280 Pressure regulating valve (Unloader) At gun closure, the waterflow is discharged in bypass reducing the pressure in the system upstream of the valve. Technical
More informationV230 VALVE OPERATING MANUAL
V230 VALVE OPERATING MANUAL S.I.A.T.A. srl Società Italiana apparecchiature trattamento acqua MAN0021 Rev. B Pag 1 di 27 DOCUMENT REVISION REVISION NOTES DATE MAN0029 A BOZZA 19/06/98 MAN0029 B EMISSIONE
More informationV230 VALVE OPERATING MANUAL
V230 VALVE OPERATING MANUAL S.I.A.T.A. srl Società Italiana apparecchiature trattamento acqua MAN0021 Rev. B Pag 1 di 24 DOCUMENT REVISION REVISION NOTES DATE MAN0029 A BOZZA 19/06/98 MAN0029 B EMISSIONE
More informationWARNING! Equipment for treatment of water intended for human consumption (Directive 98/83 CE).
WARNING! Equipment for treatment of water intended for human consumption (Directive 98/83 CE). The equipment must be used only for the utilization for which they have been designed, as shown in the technical
More informationAQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS
AQUAMATIC EASY NEST KITS INSTALLATION SUGGESTIONS TABLE OF CONTENTS TABLE OF CONTENTS...2 GENERAL RECOMMENDATIONS...2 TROUBLESHOOTING GUIDE...3 EXISTING EASY NEST SYSTEM TROUBLESHOOTING GUIDE...4 COMPONENT
More informationRegulators repair and maintenance. XS Compact 2nd stage. January 2014 Rev XSC /3 Ed. C /14 1
XS Compact 2nd stage January 2014 Rev XSC /3 Ed. C /14 1 XS Compact 2nd stage WARNING! This manual is intended for use by expert technicians who have already received training in equipment repairs and
More informationMAINTENANCE PROCEDURE FOR X 650
MAINTENANCE PROCEDURE FOR X 650 X 650 25. juli 2005-1/6 MAINTENANCE PROCEDURE FOR X 650 2 ND STAGE WARNING: This maintenance procedure is only for appointed Scubapro technicians that completed a course
More informationArt PRESSURE REDUCER
FUNCTION ICMA pressure reducers are devices that reduce and stabilize the incoming pressure from the water supply. Pressure reducers allow correct use on domestic systems, reducing malfunctions due to
More informationSimplified Digital Hydraulic Testers Operating Manual. Oil Solutions. DHC DHT HP
Webtec Products Limited Simplified Digital Hydraulic Testers Oil Solutions sales@oilsolutions.com.au Phone 0421 336 009 Fax 03 9012 4332 DHC 51-151 DHT 401-751 - 751 HP www.webtec.co.uk www.oilsolutions.com.au
More informationCARTRIDGE FILTERS TECHNICAL MANUAL MT 080. Installation, commissioning and maintenance instructions. 08/02 Edition
CARTRIDGE FILTERS TECHNICAL MANUAL MT 080 Installation, commissioning and maintenance instructions 08/02 Edition 1 2 CONTENTS 1.0 PAGE INTRODUCTION 1.1 MAIN FEATURES 1.2 OPERATION 1.3 CLOSING OF HEAD WITH
More informationTechnical Topics. Softener Elution Studies TT
Technical Topics TT-035-1204 Water softeners are critical components in many commercial and industrial water-using systems. By removing calcium and magnesium ions (hardness) from a facility s or system
More informationRARS5000 AIR BODY SAW OWNER S OPERATING MANUAL
RARS5000 AIR BODY SAW OWNER S OPERATING MANUAL DESCRIPTION 1. No mar 2. No mar tip 3. Housing grip 4. Trigger 5. Air inlet 6. Air inlet plug 7. Plastic board Important! It is essential that you read the
More informationOperating Instructions Model and Hydrostatic Test Pump
Operating Instructions Model 39300 and 39301 Hydrostatic Test Pump Dimension Weight Pump Style Capacity Pressure Motor Lubrication Control Gauge Inlet Connection Outlet Connection Discharge Hose Hose Ends
More informationVAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop
ACROBAT Vac-U-Drive Automatic Pool Cleaner VAC-U DRIVE Swinging float arm for Acrobat like agility 36 Fin disk with DEEP VEE Scoop Proven technology:diaphragm driven strength & quietness Unique hose design
More informationPULSAR4 Pressure regulating valve (Unloader)
Ultimo aggiornamento: 20/04/18 PULSAR4 Pressure regulating valve (Unloader) At gun closure, the waterflow is discharged in bypass reducing the pressure in the system upstream of the valve. Technical manual:
More informationSoftener/Filter Troubleshooting
Ten steps to determine the problem Softener/Filter Troubleshooting 1. Gather information. Ask questions, find out what is the problem. What is the customer s complaint? This may identify simple corrections
More informationPressure Reducing Valve for Steam Type 2333 A
Pressure Reducing Valve for Steam Type 2333 A Fig. 1 Type 2333 A 1. Design and principle of operation The pressure reducing valve consists of a balanced control valve and a closing actuator equipped with
More informationA3S Bellows Sealed Stop Valve Installation and Maintenance Instructions
1326050/3 IM-P132-11 ST Issue 3 A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions 1 General safety information 2 General product information 3 Installation 4 Commissioning 5 Operation
More information553 Series.
38467.03 www.caleffi.com Pre-adjustable filling units Copyright 01 Caleffi 3 Series Function The automatic filling valve is a device consisting of a pressure reducing valve with compensating seat, visual
More informationINSTALLATION & START-UP INSTRUCTIONS. Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS
INSTALLATION & START-UP INSTRUCTIONS Clack WS1 & WS1.25 METER WATER SOFTENER SYSTEMS 1999-2009 QualityWaterForLess.com - 1 - info@qualitywaterforless.com Preface: Thank you for your purchase of a new Water
More informationChloramines Removal Filter CLF20 and CLF35 Models
Chloramines Removal Filter CLF20 and CLF35 Models Operating and Maintenance Manual #51793 Rev. 6/09 Performance and Specifications Recommended Mineral Installation Shipping Item Model Media Flow Rate Tank
More informationPrestige Water Equipment Ltd.
The Prestige range of water softeners complements the range of water pre-treatment products and services. Use of water softening minimises the problems caused by hard water scale such as reduced heat transfer
More informationIMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
Warrior D.E. Filter Operating Procedures IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. FILTER INSTALLATION... 1 SECTION II. FILTER
More informationUsER manual for Watersens ph -REDOX
UsER manual for Watersens -REDOX Cl 8 1 2 6 3 3 7 7 4 4 4 4 Parts List 1 Redox Probe 1 x 2 PH Probe 1 x 5 Tube Weight 2 x 6 Connection Valve 1 x chlorine 3 Chlorine and Pumps 2 x 7 Dosing Valve 2 x 5 5
More informationSOFTENER D-DF & D-UF Series
Water conditioning System. SOFTENER D-DF & D-UF Series INSTRUCTION MANUAL, OPERATION & MAINTENANCE 1. - PRESENTATION. In this manual, what is described are the required actions for the instalment, start
More informationREVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL
REVERSE OSMOSIS WATER FILTRATION SYSTEM MODEL EWR 4075 INSTRUCTION MANUAL Excalibur Water Systems 142 Commerce Park Drive, Unit M & N Barrie, Ontario L4N 8W8 CANADA www.excaliburwater.com 2013.05.7446
More informationPULSAR4 Pressure regulating valve (Unloader)
Ultimo aggiornamento: 15/12/11 PULSAR4 Pressure regulating valve (Unloader) At gun closure, the waterflow is discharged in bypass reducing the pressure in the system upstream of the valve. Technical manual:
More informationInstruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia
Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia - 1-122.6010.6 These instructions describe the installation, operation and maintenance of the subject equipment. Failure
More informationTECHNICAL INSTRUCTIONS
TECHNICAL INSTRUCTIONS Hydroguard Series 410 Valves Model 5 and Model 8 Form TI410-5 v3 DESCRIPTION The Series 410 Hydroguard is a pressure compensating mixer which delivers a predetermined water temperature,
More informationUSE AND MAINTENANCE MANUAL V260
USE AND MAINTENANCE MANUAL V260 S.A.T.I.A. srl Società Italiana apparecchiatura trattamento acqua MAN0034 BOZZA Pag. 1 di 21 DOCUMENT REVISION REVISION NOTE DATE MAN0034 DRAFT S.A.T.I.A. srl Società Italiana
More informationVRPP 200/280 Pressure regulating valve by pneumatic control
Ultimo aggiornamento: 20/04/18 VRPP 200/280 Pressure regulating valve by pneumatic control Technical manual: E 270 The Valve, fed by compressed air, maintains the pressure steady throughout the circuit
More informationService and Repair Operative Manual MC9 1 st STAGE. MC9 1 st Stage. 1 st STAGE MC9. Jannuary Rev. MC9 /B Ed. C/13
MC9 1 st Stage 137 1 st STAGE MC9 Jannuary 2009 - Rev. MC9 /B Ed. C/13 138 WARNING! This manual is intended for use by expert technicians who should attend or have already received training in equipment
More informationUSE AND MAINTENANCE MANUAL V360
USE AND MAINTENANCE MANUAL V360 S.I.A.T.A. S.r.l Società Italiana apparecchiature trattamento acqua MAN0031 BOZZA Pag. 1 of Document Revision Revision note Date MAN0031 A Draft S.I.A.T.A. S.r.l Società
More informationInstallation and operating manual. Pneumatic control station LK product no: PCS 1-10
LK product no: PCS 1-10 Article no: 74503 Revision:8 Article no: 74503 Revision: 8 2 (23) Contents 1. General information... 5 2. Safety precautions... 5 2.1 Significance of symbols... 5 2.2 Explanatory
More informationOperating Instructions Model and Hydrostatic Test Pump
Operating Instructions Model 29200 and 2920 Hydrostatic Test Pump Dimension Weight Pump Pressure for 29200 Pump Pressure for 2920 Gauge for 29200 Gauge for 2920 Inlet Connection Outlet Connection Hose
More informationINSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300
INSTALLATION, OPERATION, SERVICE & PARTS MANUAL FOR STOCK POT RANGE MODELS VSP100, VSP200 & VSP300 MODEL VSP100 VULCAN-HART COMPANY, P.O. BOX 696, LOUISVILLE, KY 40201-0696, TEL. (502) 778-2791 FORM 30780
More informationProduct Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment
Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces
More informationInstructions for SILEX 1C Mixed bed cartridge filter
D01B-30A-UK1 January 2017 Instructions for SILEX 1C Mixed bed cartridge filter With conductivity sensor Gravity flow or pressure installation SILHORKO-EUROWATER A/S Phone +45 86 57 12 22 DK-8660 Skanderborg
More information5 Gallon Pressure Pot with HVLP Spray Gun and Hose
California Air Tools 5 Gallon Pressure Pot with HVLP Spray Gun and Hose Model No. 365 Technical Data Type of feed.pressure Maximum pressure in the tank... 0,413Mpa (60PSI) Working pressure in the tank.0,
More information12S 1st Stage. -Maintenance Procedure-
12S 1st Stage -Maintenance Procedure- 1 Warning! All maintenance and repair procedures MUST be performed by a Mares authorized Service Center and/or Distributor. Therefore, the information provided below
More informationOPERATION MANUAL NTF-15
OPERATION MANUAL NTF-15 Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81235-00 (Rev B) TABLE
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-90
Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationInstallation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr
Installation and Maintenance Manual ECO Filtration Unit with 6-way-Top-Mount-Valve Art. Nr. 300100 300101 300102 Important Details: - Using of this filtration unit for swimming pools and its guard band
More informationAccu-Tab Systems 2000 P Series by Axiall Corporation
Accu-Tab Systems 2000 P Series by Axiall Corporation Installation and Operating Instructions Models 2075 P 2150 P For NSF/ANSI-Standard 61 NSF STANDARD 61 applications use NSF/ANSI Standard 60 listed Axiall
More informationOPERATION MANUAL NTF-60 Plus
OPERATION MANUAL NTF-60 Plus Nitrogen Tire Filling Valve Stem Caps (Qty=200) Order P/N 436075 RTI Technologies, Inc 10 Innovation Drive York, PA 17402 800-468-2321 www.rtitech.com 035-81264-00 (Rev A)
More informationTECHNICAL DATA CAUTION
Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.
More informationMODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL
MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL Index 1. List of components / General arrangement 2. Description 3. Handling 4. Installation 5. Actuators / Operation 6. Maintenance a. Changing
More informationaccidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 2 INCH BRAD NAILER Model: 7555 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationMounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity
Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating
More informationInstallation Instructions
Installation Instructions COLONY SOFT 7.0 Single Control Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a feature found
More informationaccidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS
18 GAUGE 1-1/4 INCH BRAD NAILER Model: 7611 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.
More informationModel: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering
Bermad Pressure Reducing Valve Model: 720-UL INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 1. Safety First BERMAD believes that the safety of personnel working with and around our equipment
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS HIGH PRESSURE PUMP To minimize vibration, it is best to build brackets on the motor itself, similar to alternator brackets. Use cardboard to construct a pattern first before making
More informationCalcium Reactor. CalcFeeder PRO. User Manual 1.1a. Model. CalcFeeder AC1 PRO CalcFeeder AC2 PRO CalcFeeder AC3 PRO CalcFeeder AC4 PRO
Calcium Reactor CalcFeeder PRO User Manual 1.1a Model CalcFeeder AC1 PRO CalcFeeder AC2 PRO CalcFeeder AC3 PRO CalcFeeder AC4 PRO Page 1 Dear Customer, Thank you for purchasing an Pacific Sun CalcFeeder
More informationFILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS
FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.
More informationCSA Sample Draw Aspirator Adapter Operator s Manual
30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationPure Water Power Purification System 4-Stage RODI Operations Manual
Pure Water Power Purification System 4-Stage RODI Operations Manual Flush Valve Lever Quick Disconnect for RO Water Testing Water Supply In Drain Hose Pure Water Out to Waterfed Pole New Machine Setup
More informationAssembly Drawing: W-311B-A01, or as applicable Parts List: W-311B-A01-1, or as applicable Special Tools: , , &
REDQ Regulators Model 411B Barstock Design Powreactor Dome Regulator OPERATION AND MAINTENANCE Contents Scope..............................1 Installation..........................1 General Description....................1
More information1020 Industrial Drive, Orlinda, TN fax
Operation Manual Ultrafiltration for High Purity Distribution K-A-HPTUF Series 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and Cautions... 1 1.2
More informationWALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED
WALL MOUNTED EMERGENCY EYE & EYE/FACE WASH HAND OPERATED Installation, Operating & Maintenance Instructions EEE120 EFE300 I00097_Oct 17 NOTE: THIS DOCUMENT IS TO BE LEFT ONSITE WITH FACILITY MANAGER AFTER
More informationFlanged pressure reducer/stabilizer VRCD
Flanged pressure reducer/stabilizer VRCD 2 This unit reduces and stabilizes the upstream pressure by operating on its load losses with a constant downstream pressure irrespective of the rate of flow value.
More informationLatvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.
Product Specification ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.0 bar Latvin Luxury Shower Panel ~ Fixing Centres 150mm +/- 10mm ~ Outlet size 1/2" Bottom Outlet Always maintain a
More informationRB70 Automatic Diluent Valve Maintenance Manual. Version 1.1 November 2006 Written by Tino de Rijk. Page 1 of 23
RB70 Automatic Diluent Valve Maintenance Manual Version 1.1 November 2006 Written by Tino de Rijk Page 1 of 23 Table of Contents 1. Introduction... 3 2. ADV diagram and parts list (Pre June 2006)... 4
More informationCART FOR CENTURION 1500+
CART FOR CENTURION 1500+ Operation & Maintenance Manual www.ameriwater.com 800-535-5585 AmeriWater 3345 Stop 8 Rd. Dayton, OH 45414 98-0161 Rev A Contents 1. GENERAL INFORMATION... 1 1.1. Features...
More informationbathrooms.com Concentric Thermostatic Shower Mixers Cleaning and Care Installation Manual Contents
bathrooms.com Concentric Thermostatic Shower Mixers Contents Page 3 - General Information & Safety Page 4 - Installation Page 5 - Concentric Valve Set-up Page 6 - Exposed fitting of Concentric Mixer Valves
More informationProduct Information News September 26, 2003
Product Information News September 26, 2003 LEVER HEIGHT INSPECTION FOR FIREHAWK MMR MSA is announcing a revision to the instructions for the Firehawk MMR Second Stage Regulator as they relate to the air
More informationSerie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E
Serie ECO T Threaded end back flow preventer with controllable reduced pressure zone BRANDONI made in E U R O P E Application fields WATER FIRE FIGHTING DRINKING WATER 74 www.brandoni.it Serie ECO T The
More informationRegulator from 1800 B series
Regulator from 1800 B series Regulator from 1800 B series Measuring of industrial gases frequently requests a precise pressure regulation for the purpose of dosage and proccesing. UNIS FAGAS has two kinds
More informationOperating and maintenance manual Filter and reducing station Series / 1.0
Operating and maintenance manual Filter and reducing station Series 961 04.2017 / 1.0 Original instructions ARCA Regler GmbH. All rights reserved. Cover picture background: Freepik.com ARCA Regler GmbH
More informationVRPP 170 Pressure regulating valve by pneumatic control
Last update: 02/11/2011 VRPP 170 Pressure regulating valve by pneumatic control Pressure regulating valve. At gun shut off, the water flow is bypassed at reduced pressure. Technical manual: E 246 DN 25
More informationKTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood SECTION 1 - STORAGE 1.1 Preparation and preservation for storage All valves should be properly packed in order to protect the parts
More informationUltRo Dual Flow Reverse Osmosis Water System
UltRo Dual Flow Reverse Osmosis Water System Congratulations on this great investment to your health. **IMPORTANT NOTE BEFORE YOU BEGIN** We recommend you call your local friendly plumber to ensure proper
More informationD05 Pressure Regulating Valves
D05 Pressure Regulating Valves FEATURES PRODUCT DATA Noncorroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass. Balanced seat construction
More informationTesting Procedures & Trouble Shooting Guide Reduced Pressure Zone Assembly (1/2, 3/4", 1, 1 1/4, 1 1/2" & 2 )
Testing Procedures & Trouble Shooting Guide Reduced Pressure Zone Assembly (1/2, 3/4", 1, 1 1/4, 1 1/2" & 2 ) First Check Valve Test 1) Bleed all test cocks. First open test cock 4, make sure it is slightly
More informationIMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION
IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION This Fitting Guide is designed to assist in the Installation of your Reverse Osmosis System. Some of the parts that are supplied with each system may
More informationInstallation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.
Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow Model: FP 450-80 Installation Operation Maintenance PAGE 1 OF 5 1. Safety First BERMAD believes that the safety of personnel
More informationBuild Your Own Flamethrower Step-by-step Manual
Build Your Own Flamethrower Step-by-step Manual Table of Contents: Parts List.. page 1 Operation...page 6 Diagrams. pages 7-9 Parts list: Required: Air tank (large) Pressure washer gun with high-pressure
More information1200B2 Series Service Regulators. Instruction Manual
00B Series Service Regulators Instruction Manual 00B Series Service Regulators 0 Elster American Meter 00B Series Service Regulators General Information The 00B Series Service Regulators are available
More informationFunction. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2
utomatic filling units series 55 cert. n ISO 9 5/5 G Replaces 5/ G unction he automatic filling unit is a device consisting of a pressure reducing valve with compensating seat, an inlet strainer, a shut-off
More informationBASIN AND WALL MIXER INSTALLATION INSTRUCTIONS
BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION IMPORTANT All tapware and showers to be installed by a licensed plumber and to Australian Standards. Fit tempering and pressure reduction
More informationHGC-200 Hydro Gas Chlorinator
HGC-200 Hydro Gas Chlorinator ProMinent Fluid Controls Pty Ltd Head Office: Unit 4, 4 Narabang Way BELROSE NSW 2085 AUSTRALIA (PO Box 85, BELROSE WEST NSW 2085) Phone: (02) 9450 0995 Fax: (02) 9450 0996
More informationINSTALLATION & START-UP INSTRUCTIONS FLECK 9100SXT METER TWIN ALTERNATING WATER SOFTENER SYSTEMS
INSTALLATION & START-UP INSTRUCTIONS FLECK 9100SXT METER TWIN ALTERNATING WATER SOFTENER SYSTEMS 1999-2007 QualityWaterForLess.com - 1 - info@qualitywaterforless.com Preface: Thank you for your purchase
More informationMounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type
Type 4708 Supply Pressure Regulators Translation of original instructions Type 4708-53 Type 4708-64 Type 4708-12 Mounting and Operating Instructions Edition March 2018 Note on these mounting and operating
More informationAuto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL
Auto-Rewind Hose Reels INSTRUCTION MANUAL FOR OXY-LPG MODEL Introduction Thank you for purchasing a Retracta Auto Rewind Hose Reel. The Retracta range of hose reels are a breakthrough in industrial quality
More informationINSTALLATION INSTRUCTIONS
EDGEMERE CENTERSET LAVATORY FAUCET INSTALLATION INSTRUCTIONS 708.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds
More informationBermad Pressure Reducing. Model: 42T
Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel