NEW Dual Certified Ex d & Ex e UNIONS Multi Angle Unions for Explosive Atmospheres CMP PRODUCTS

Size: px
Start display at page:

Download "NEW Dual Certified Ex d & Ex e UNIONS Multi Angle Unions for Explosive Atmospheres CMP PRODUCTS"

Transcription

1 NW ual Certified x d & x e UNIONS Multi Angle Unions for xplosive Atmospheres CMP PROUCTS

2 780 SRIS Inline Union Union Type 780 with lameproof x d IIC & Increased Safety x e II forms of protection. The CMP Type 780 Metallic Union is designed to allow connection of rigid and flexible conduit, or terminated Cable Glands, to any fixed equipment. The 780 Union provides a running connection by means of an integral coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct termination. The ease of installation offered by the 780 Union consequently makes the process of removing the conduit or other terminated cable entry device from the equipment a simple, fast and effective one. Available in rass, lectroless Nickel Plated rass, Aluminium or Stainless Steel these Unions are approved for use in conjunction with Class I, iv 1 and 2, x d and x e certified equipment and cable entry devices, and can also be supplied with thread conversion between the forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to, or to metric. Type 780 II 2 G x d IIC Gb, x e IIC Gb, x ta IIIC a IP6X x d IIC Gb, x e IIC Gb, x d I Mb, x e I Mb, x ta IIIC a IP6X Class I, iv 1 & 2, Groups A,,C, ; nclosure type 4X : Class I, Zone 1, TC C-G.ГБ x d IIC Gb U, x e IIC Gb U, x ta IIIC a U C A A General Purpose Industrial version is also available. Available with an integral O Ring seal. or such options please add above, e.g. 780RM2M2. NPSI Certificate GYJ X x d IIC Gb G3836.1,2,3-60 C to +200 C rass (standard), lectroless Nickel Plated rass, Aluminium, Stainless Steel (rass, Metric) MTRIC orward A emale (rass, ) orward emale ore iameter C lats Hex Ø 780M2M2 M20 X M20 X T1T1 1/ / M3M3 M25 X M25 X T2T2 3/ / M4M4 M32 X M32 X T3T M5M5 M40 X M40 X T4T4 1-1/ / M6M6 M50 X M50 X T5T5 1-1/ / M7M7 M63 X M63 X T6T M8M8 M75 X M75 X T7T7 2-1/ / M9M9 M90 X M90 X T8T or material options please add the following suffix to the ; rass (no suffix required), Nickel Plated rass 5, 316 Grade Stainless Steel 4, Copper ree Aluminium 1

3 PX780RX SRIS Inline arrier Union *Ordered seperately arrier Union Type PX780RX with lameproof x d IIC & Increased Safety x e II forms of protection. The CMP Type PX780RX Rapidx Metallic arrier Union is designed to allow connection of rigid and flexible conduit, or terminated Cable Glands, to any fixed equipment. The PX780RX Union provides a running connection by means of an integral coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct termination. Type PX780RX II 2 G x d IIC Gb, x e IIC Gb, x ta IIIC a IP6X C A The PX780RX also incorporates a barrier compartment. The ease of installation offered by the PX780RX arrier Union consequently makes the process of removing the conduit or other terminated cable entry device from the equipment a simple, fast and effective one. Available in rass, lectroless Nickel Plated rass, Aluminium or Stainless Steel these arrier Unions are approved for use in conjunction with Class I, iv 1 and 2, x d and x e certified equipment and cable entry devices, and can also be supplied with thread conversion between the forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to, or to metric. x d IIC Gb, x e IIC Gb, x d I Mb, x e I Mb, x ta IIIC a IP6X Class I, iv 1 & 2, Groups A,,C, ; nclosure type 4X : Class I, Zone 1, TC C-G.ГБ x d IIC Gb U, x e IIC Gb U, x ta IIIC a U Available with an integral O Ring seal. or such options please add above, e.g. PX780RXRM2M2. or epoxy compound version please remove RX from ordering reference -60 C to +85 C rass (standard), lectroless Nickel Plated rass, Aluminium, Stainless Steel (rass, Metric) MTRIC orward emale Size (rass, ) orward emale iameter Over Cores C. Number of Cores Postrusion lats Hex Ø PX780RXM2M2 M20 X M20 X 1.5 PX780RXT1T1 1/ / PX780RXM3M3 M25 X M25 X 1.5 PX780RXT2T2 3/ / PX780RXM4M4 M32 X M32 X 1.5 PX780RXT3T PX780RXM5M5 M40 X M40 X 1.5 PX780RXT4T4 1-1/ / PX780RXM6M6 M50 X M50 X 1.5 PX780RXT5T5 1-1/ / PX780RXM7M7 M63 X M63 X 1.5 PX780RXT6T PX780RXM8M8 M75 X M75 X 1.5 PX780RXT7T7 2-1/ / PX780RXM9M9 M90 X M90 X 2.0 PX780RXT8T or material options please add the following suffix to the ; rass (no suffix required), Nickel Plated rass 5, 316 Grade Stainless Steel 4, Copper ree Aluminium 1

4 784 SRIS 45 Union Union With 45 end Type 784 with lameproof x d IIC & Increased Safety x e II forms of protection. The CMP Type 784 Metallic Union is designed to allow connection of rigid and flexible conduit, or terminated Cable Glands, to any fixed equipment. The 784 Union provides a running connection at an angle of 45 by means of an integral coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct termination. The ease of installation offered by the 784 Union consequently makes the process of removing the conduit or other terminated cable entry device from the equipment a simple, fast and effective one. Available in rass, lectroless Nickel Plated rass, Aluminium or Stainless Steel these Unions are approved for use in conjunction with Class I, iv 1 and 2, x d and x e certified equipment and cable entry devices, and can also be supplied with thread conversion between the forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to, or to metric. A General Purpose Industrial version is also available. If 2 separate enclosures are required to be connected together please contact CMP Type 784 NPSI Certificate II 2 G x d IIC Gb, x e IIC Gb, x ta IIIC a IP6X x d IIC Gb, x e IIC Gb, x d I Mb, x e I Mb, x ta IIIC a IP6X C A G Class I, iv 1 & 2, Groups A,,C, ; nclosure type 4X : Class I, Zone 1, TC C-G.ГБ x d IIC Gb U, x e IIC Gb U, x ta IIIC a U GYJ X x d IIC Gb G3836.1,2,3 Available with an integral O Ring seal. or such options please add above, e.g. 784RM2M C to +200 C rass (standard), lectroless Nickel Plated rass, Aluminium, Stainless Steel (rass, Metric) orward MTRIC emale (rass, ) orward emale ore iameter C Overhang lats Hex Ø 784M2M2 M20 X M20 X T1T1 1/ / M3M3 M25 X M25 X T2T2 3/ / M4M4 M32 X M32 X T3T M5M5 M40 X M40 X T4T4 1-1/ / M6M6 M50 X M50 X T5T5 1-1/ / M7M7 M63 X M63 X T6T or material options please add the following suffix to the ; rass (no suffix required), Nickel Plated rass 5, 316 Grade Stainless Steel 4, Copper ree Aluminium 1

5 PX784RX SRIS 45 arrier Union *Ordered seperately arrier Union with 45 bend Type PX784RX with lameproof x d IIC & Increased Safety x e II forms of protection. The CMP Type PX784RX Metallic arrier Union is designed to allow connection of rigid and flexible conduit, or terminated Cable Glands, to any fixed equipment at a 45 angle. The PX784RX Union provides a running connection by means of an integral coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct termination. The PX784RX also incorporates a barrier compartment. The ease of installation offered by the PX784RX arrier Union consequently makes the process of removing the conduit or other terminated cable entry device from the equipment a simple, fast and effective one. Type PX784RX II 2 G x d IIC Gb, x e IIC Gb, x ta IIIC a IP6X x d IIC Gb, x e IIC Gb, x d I Mb, x e I Mb, x ta IIIC a IP6X C A G Available in rass, lectroless Nickel Plated rass, Aluminium or Stainless Steel these arrier Unions are approved for use in conjunction with Class I, iv 1 and 2, x d and x e certified equipment and cable entry devices, and can also be supplied with thread conversion between the forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to, or to metric. If 2 separate enclosures are required to be connected together please contact CMP Class I, iv 1 & 2, Groups A,,C, ; nclosure type 4X : Class I, Zone 1, TC C-G.ГБ x d IIC Gb U, x e IIC Gb U, x ta IIIC a U Available with an integral O Ring seal. or such options please add above, e.g. PX784RXRM2M2. or epoxy compound version please remove RX from ordering reference -60 C to +85 C rass (standard), lectroless Nickel Plated rass, Aluminium, Stainless Steel (rass, Metric) MTRIC orward emale Size (rass, ) orward emale Size iameter over Cores C. number of Cores Overhang lats Hex Ø PX784RXM2M2 M20 X M20 X 1.5 PX784RXT1T1 1/ / PX784RXM3M3 M25 X M25 X 1.5 PX784RXT2T2 3/ / PX784RXM4M4 M32 X M32 X 1.5 PX784RXT3T PX784RXM5M5 M40 X M40 X 1.5 PX784RXT4T4 1-1/ / PX784RXM6M6 M50 X M50 X 1.5 PX784RXT5T5 1-1/ / PX784RXM7M7 M63 X M63 X 1.5 PX784RXT6T or material options please add the following suffix to the ; rass (no suffix required), Nickel Plated rass 5, 316 Grade Stainless Steel 4, Copper ree Aluminium 1

6 789 SRIS 90 Union Union With 90 end Type 789 with lameproof x d IIC & Increased Safety x e II forms of protection. The CMP Type 789 Metallic Union is designed to allow connection of rigid and flexible conduit, or terminated Cable Glands, to any fixed equipment. The 789 Union provides a running connection at an angle of 90 by means of an integral coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct termination. The ease of installation offered by the 789 Union consequently makes the process of removing the conduit or other terminated cable entry device from the equipment a simple, fast and effective one. Available in rass, lectroless Nickel Plated rass, Aluminium or Stainless Steel these Unions are approved for use in conjunction with Class I, iv 1 and 2, x d and x e certified equipment and cable entry devices, and can also be supplied with thread conversion between the forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to, or to metric. A General Purpose Industrial version is also available. If 2 separate enclosures are required to be connected together please contact CMP Type 789 NPSI Certificate II 2 G x d IIC Gb, x e IIC Gb, x ta IIIC a IP6X x d IIC Gb, x e IIC Gb, x d I Mb, x e I Mb, x ta IIIC a IP6X Class I, iv 1 & 2, Groups A,,C, ; nclosure type 4X : Class I, Zone 1, TC C-G.ГБ x d IIC Gb U, x e IIC Gb U, x ta IIIC a U GYJ X x d IIC Gb C A G Available with an integral O Ring seal. or such options please add above, e.g. 789RM2M2. G3836.1,2,3-60 C to +200 C rass (standard), lectroless Nickel Plated rass, Aluminium, Stainless Steel (rass, Metric) orward MTRIC emale Size (rass, ) orward emale ore iameter C Overhang lats Hex Ø 789M2M2 M20 X M20 X T1T1 1/ / M3M3 M25 X M25 X T2T2 3/ / M4M4 M32 X M32 X T3T M5M5 M40 X M40 X T4T4 1-1/ / M6M6 M50 X M50 X T5T5 1-1/ / M7M7 M63 X M63 X T6T or material options please add the following suffix to the ; rass (no suffix required), Nickel Plated rass 5, 316 Grade Stainless Steel 4, Copper ree Aluminium 1

7 PX789RX SRIS 90 arrier Union *Ordered seperately arrier Union with 90 bend Type PX789RX with lameproof x d IIC & Increased Safety x e II forms of protection. The CMP Type PX789RX Metallic arrier Union is designed to allow connection of rigid and flexible conduit, or terminated Cable Glands, to any fixed equipment at a 90 angle. The PX789RX Union provides a running connection by means of an integral coupling arrangement that eliminates the need to rotate the conduit, or cable, or equipment to achieve a correct termination. The PX789RX also incorporates a barrier compartment. The ease of installation offered by the PX789RX arrier Union consequently makes the process of removing the conduit or other terminated cable entry device from the equipment a simple, fast and effective one. Type PX789RX II 2 G x d IIC Gb, x e IIC Gb, x ta IIIC a IP6X x d IIC Gb, x e IIC Gb, x d I Mb, x e I Mb, x ta IIIC a IP6X C A G Available in rass, lectroless Nickel Plated rass, Aluminium or Stainless Steel these arrier Unions are approved for use in conjunction with Class I, iv 1 and 2, x d and x e certified equipment and cable entry devices, and can also be supplied with thread conversion between the forward and rear threads to either a reduced size or a variety of different thread types, e.g. Metric to, or to metric. If 2 separate enclosures are required to be connected together please contact CMP Class I, iv 1 & 2, Groups A,,C, ; nclosure type 4X : Class I, Zone 1, TC C-G.ГБ x d IIC Gb U, x e IIC Gb U, x ta IIIC a U Available with an integral O Ring seal. or such options please add above, e.g. 7PX89RXRM2M2. or epoxy compound version please remove RX from ordering reference -60 C to +85 C rass (standard), lectroless Nickel Plated rass, Aluminium, Stainless Steel (rass, Metric) MTRIC orward emale Size (rass, ) orward emale Size iameter over Cores C. number of Cores Overhang lats Hex Ø PX789RXM2M2 M20 X M20 X 1.5 PX789RXT1T1 1/ / PX789RXM3M3 M25 X M25 X 1.5 PX789RXT2T2 3/ / PX789RXM4M4 M32 X M32 X 1.5 PX789RXT3T PX789RXM5M5 M40 X M40 X 1.5 PX789RXT4T4 1-1/ / PX789RXM6M6 M50 X M50 X 1.5 PX789RXT5T5 1-1/ / PX789RXM7M7 M63 X M63 X 1.5 PX789RXT6T or material options please add the following suffix to the ; rass (no suffix required), Nickel Plated rass 5, 316 Grade Stainless Steel 4, Copper ree Aluminium 1

8 NWCASTL (Headquarters) Tel: +44 (0) ax: +44 (0) Mail: CMP Products 36, Nelson Way, Nelson Park ast Cramlington, Northumberland N23 1WH, United Kingdom HOUSTON (Texas Inc) Tel: ax: Mail: CMP Products Texas Inc 5222 N. Sam Houston Pkwy. Houston, Texas, 77032, USA PRTH, WA Tel: ax: Mail: perthoffice@cmp-products.com CMP Products Pty Ltd Unit 3-22 Harlond Avenue, Malaga, WA 6090 Australia RISAN, QL Tel: ax: Mail: qldoffice@cmp-products.com CMP Products Pty Ltd Unit 2 / 1-5 Knobel Court, Shailer Park, QL 4128 Australia UAI Tel: ax: Mail: meoffice@cmp-products.com CMP Products Middle ast Office Office 6WA Room 134, PO OX ubai Airport ree Zone, ubai, United Arab mirates PUSAN Tel: ax: Mail: pusanoffice@cmp-products.com CMP Products (Korea) Ltd 19 Rm1915 Centum IS Tower, #1209, Jaesong1-dong, Haeundae-gu, usan, South Korea, SINGAPOR Tel: ax: Mail: seaoffice@cmp-products.com CMP Products (S..A) Pte Ltd. 21 Toh Guan Road ast, #09-03, Toh Guan Centre, Singapore SHANGHAI Tel: ax: Mail: shanghaioffice@cmp-products.com CMP Products ivision Room 304, uilding 7, No.1888 XinJinqiao Road Pudong, Shanghai , P.R. China CMP PROUCTS TPC Issue 2-07/14 JOHANNSURG Tel: ax: Mail: africaoffice@cmp-products.com CMP Products 49 New Road, lock A, Ground loor Midrand,1685, Johannesburg, S.A

3.1. Ex-e/i Cable Glands Plastic version for Zone 1, 2, 21 and according to EN : 2012

3.1. Ex-e/i Cable Glands Plastic version for Zone 1, 2, 21 and according to EN : 2012 .1 x-e/i Cable Glands Plastic version for Zone 1, 2, 21 and 22 1 - according to N 60079-0: 2012 Conform with latest standards Cable glands with metric screwin threads are now standard and had replace the

More information

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring

More information

REDUCER. Ex db, Ex eb, Ex tb, Ex nr, IP65/66/68. for General Industrial and Ex de I/IIC/IIC, Ex nr IIC

REDUCER. Ex db, Ex eb, Ex tb, Ex nr, IP65/66/68. for General Industrial and Ex de I/IIC/IIC, Ex nr IIC TM TM TÜVRheinland RUR x db, x eb, x tb, x nr, IP65/66/68 for eneral Industrial and x de I/II/II, x nr II L TRMIN TIONS eatures and enefits Precision manufactured from high quality brass (marine grade

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

PEPPERS CABLE GLANDS.

PEPPERS CABLE GLANDS. PEPPERS CABLE GLANDS MORE THAN THE SUM OF OUR PARTS,, A l. unit minimises the possibility of occuring during installation and deluge protection is achieved without the use of additional sealing devices.

More information

Cable Glands. Special Applications. RoHS Compliance. Plastic & Metal Cable Glands Adapters Reducers & Enlargers Grommets & Accessories

Cable Glands. Special Applications. RoHS Compliance. Plastic & Metal Cable Glands Adapters Reducers & Enlargers Grommets & Accessories able Glands RoHS ompliance Plastic & Metal able Glands dapters Reducers & Enlargers Grommets & ccessories L File #: E363825 cable gland is a device that allows the user to pass a cable, wire or tube into

More information

44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES

44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES WALL BOXES IN GWPLAST 75 - GWT 650 C GWT 650 C TP 85 C WALLS WITH CABLE GLAND - IP44 AND IP55 GW44001 JUNCTION BOXES WITH PLAIN PRESS-ON LID - IP44 - GREY RAL 7035 LxHxD (mm) No. holes / Ø GW 44 001 Ø

More information

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT IEC 649 COMPLIANT METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES INTRODUCTION Current transformer open circuit protection with reliability, flexibility and expertise built-in. Current Transformer

More information

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures for OEM Applications Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures, the latest addition to our portfolio of electrical

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment

More information

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar) Assembly instruction 1 2 3 4 5 6 7 1. Entry Component 2. Compound Sleeve 3. Interlocking Armour Cone 4. Armour Clamping Ring 5. Gland Body 6. Outer Sheath Sealing 7. Dome Nut 8. Compound 8 Operating temperature

More information

Certificate of Conformity

Certificate of Conformity Certificate of Conformity Certificate Holder: CCG Cable Terminations (PTY) LTD 33 37 Forge Road Spartan Industrial Area, Kempton Park 1619 SOUTH AFRICA Electrical Apparatus: A2F, A2FX, and A2FCG Cable

More information

Plok. Rapid Mating Multi-Pin Industrial Connector. Amphenol Industrial Sine Systems * Pyle Connectors Corporation

Plok. Rapid Mating Multi-Pin Industrial Connector. Amphenol Industrial Sine Systems * Pyle Connectors Corporation - Plok Rapid Mating Multi-Pin Industrial onnector mphenol Industrial Sine Systems * Pyle onnectors orporation eatures and enefits Rapid mate spring loaded, push to mate, pull to unmate coupling system

More information

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1. > Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:

More information

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS CONSTRUCTION FEATURES ENCLOSURE OPERATING TEMPERATURE 20 C/+60 C COVER Diecast aluminium (anodised) WEIGHT CSN 5 3.5 kg CSN 8 5 kg CSN

More information

Junction Boxes Series 8118

Junction Boxes Series 8118 > Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature

More information

Hydro Bond Engineering Ltd Electrical Penetrators: Manned and Unmanned Systems HPS (Hydro Bond Penetrator Series)

Hydro Bond Engineering Ltd Electrical Penetrators: Manned and Unmanned Systems HPS (Hydro Bond Penetrator Series) Hydro Bond Engineering Ltd Electrical Penetrators: sales@hydrogroup.uk www.hydrogroupcom tel: +44 (0)1224 822996 fax: +44 (0)1224 825142. sales@hydrogroup.uk www.hydrogroup-asia.com tel: +65 63343566 fax:

More information

1805 Series Relief Valves

1805 Series Relief Valves Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion

More information

Pressure Equalising Valves Model , for Differential Pressure Gauges

Pressure Equalising Valves Model , for Differential Pressure Gauges Accessories Pressure Equalising Valves Model 910.25, for Differential Pressure Gauges WIKA Data Sheet AC 09.11 Applications T Isolating, pressure equalising as well as purging and air bleeding valves to

More information

Terminal Head Section User Guide

Terminal Head Section User Guide Example: Terminal Heads Terminal Head Section User Guide Ø100 105 Ø52 Process Conduit Entry Entry KNC 3/4 M20 x 1.5 4.25 5.53 62 34.5 IP6 200 o C Product Photograph 14 Technical Drawing (measurements in

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

Series CGCN self-centering three-jaw grippers with T-guide

Series CGCN self-centering three-jaw grippers with T-guide HANDLING AND VACUUM 2019 GRIPPERS > Series CGCN self-centering three-jaw grippers with T-guide New Double acting, magnetic Sizes: 50, 64, 80, 100, 125 mm The new Series CGCN pneumatic grippers are available

More information

HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR DEH SERIES

HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR DEH SERIES HAZARDOUS AREA DIFFERENTIAL CLOGGING INDICATOR PASSION TO PERFORM Filter elements are efficient only if their dirt holding capacity is fully exploited. This is achieved by using filter housings equipped

More information

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction....................................................................................... 3

More information

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN

Series INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries. Description ALL STAINLESS DESIGN INTELLIGENT PRESSURE- AND LEVEL TRANSMITTERS For all industries Series 2000 ALL STAINLESS DESIGN EASY CALIBRATION WITHOUT TEST PRESSURE BY 3 PUSH BUTTONS ACCURACY 0,1% 4-20 ma AND HART PROTOCOL ATEX II

More information

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE Compiled by: Arthur Cameron NOT SO CORRECT SELECTION AND INSTALLATION OF CABLE GLANDS AND JUNCTION BOXES IN HAZARDOUS AREAS

More information

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications

Technical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR

More information

1305 Series Pressure Reducing Regulators

1305 Series Pressure Reducing Regulators Instruction Manual Form 1095 1305 Series October 2009 1305 Series Pressure Reducing Regulators! Warning Fisher regulators must be installed, operated, and maintained in accordance with federal, state,

More information

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR 05.0046U SERIAL No 20 TYPE SX Ex e II C Gb Ex tb IIIC Db IP6* IECEx SIR

More information

February Cable glands For general industry and hazardous areas

February Cable glands For general industry and hazardous areas February 2017 Cable glands For general industry and hazardous areas Introduction When safety matters, there is only one choice The Nicote and Kopex range of cable glands come to ABB through the acquisition

More information

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No.

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No. IECEx Cert f cate of Gonform ty INTERNATIONAL ELECTROTECHNIGAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.tecex.com Certificate No.

More information

@h..p. lntertek. IECEx Certificate of Conformity

@h..p. lntertek. IECEx Certificate of Conformity ECEx Certificate of Conformity NTERNATONAL ELECTROTECHNCAL COMMSSON EC Certification Scheme for Explosive Atmospheres for rules and details of the ECElC Scheme visit www.iecex.com Certificate No.: { ECclC

More information

Pressure switch, Differential pressure switch and Thermostat RT-E

Pressure switch, Differential pressure switch and Thermostat RT-E Data sheet Pressure switch, Differential pressure switch and Thermostat RT-E The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial

More information

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell Fully Approved

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell Fully Approved MTB Load Cell Process Weighing Due to the hermetically sealed design, MTB is ideal for harsh environments in process or food applications. The full set of approvals makes it the right choice for your application.

More information

Industrial cable glands

Industrial cable glands Industrial cable glands SK-EMC cable glands Cable glands of the SK-series fulfil the highest demands of quality and security. Outstanding high-grade materials are used together with innovative technology

More information

ELECTRIC ACTUATORS for continuous underwater use

ELECTRIC ACTUATORS for continuous underwater use ELECTRIC ACTUATORS for continuous underwater use The SA multi-turn actuator for continuous underwater use by AUMA opens new applications for electric actuators for water supply, in hydropower plants and

More information

Series CGZT three-jaw grippers with T-guide

Series CGZT three-jaw grippers with T-guide Series CGZT three-jaw grippers with T-guide New Single and double acting, magnetic, self-centering Sizes: 40, 50, 64, 80, 100, 125, 160 mm The new Series CGZT pneumatic grippers, thanks to the use of a

More information

VEP-HDSERIES INTERCHANGE > Stucchi VEP profile

VEP-HDSERIES INTERCHANGE > Stucchi VEP profile V-HSRIS INRHAN > Stucchi V profile HNIAL AURS AN OIONS SUHI SOLUIONS Interchange Stucchi V profile Sealing description Nitrile NR onnection system Screw HL version= lock system Available sizes Material

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit > A Higher Level of Performance Data Sheet Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Description Intelligent pressure and level transmitters for all industries

More information

ITS 300 & 500 SERIES POSITION MONITORING INSTALLATION AND OPERATION MANUAL

ITS 300 & 500 SERIES POSITION MONITORING INSTALLATION AND OPERATION MANUAL ITS 300 & 500 SERIES POSITION MONITORING ITS 300 & 500 SERIES POSITION MONITORING INSTALLATION AND OPERATION MANUAL (Explosion proof Ex d II T6) (Doc no: ITS00312-M) 74-6, hun Ui-Dong, Won Mi-Gu, Bucheon

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 10.0014 Issue No.: 2 Equipment: The Series 1200 range of blanking plugs, reducers and conversions are manufactured from mild steel, stainless steel or brass alloy and are

More information

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

VEP-PSERIES INTERCHANGE > Stucchi VEP profile

VEP-PSERIES INTERCHANGE > Stucchi VEP profile VPPSRIS INRHAN > Stucchi VP profile HNIAL AURS AN OPIONS Interchange Stucchi VP profile Sealing description Nitrile NR onnection system Screw SUHI SOLUIONS Available sizes Material /treatment Available

More information

PRESSURE REGULATORS. Type A/140. Process Management TM

PRESSURE REGULATORS. Type A/140. Process Management TM PRESSURE REGULATORS Type A/140 Process Management TM A/140 Series Pressure Regulator The regulators of the A/140 series due to their operating specifications are mainly used in those system where sudden

More information

Cameron MBS Multi-Bowl Wellhead System

Cameron MBS Multi-Bowl Wellhead System Cameron MBS Multi-Bowl Wellhead System MBS Multi-Bowl Wellhead System Tubing Head Adapter Tubing Hanger Upper Casing Spool Pack-off Bushing Emergency Slip and Seal Assembly Lower Casing Head Standard MBS

More information

Technical Guideline for Selection of Cable Gland

Technical Guideline for Selection of Cable Gland I-ACC FlameProof & WeatherProof Technical Guideline for Selection of Cable Gland Cable Glands Reducers Nipples Couplings Plugs Breathers Bends Tees Inspection Elbows Flexible Hoses Enclosed Break Lamp

More information

Heavy Duty Pocket Insets for the Oil & Gas Industry

Heavy Duty Pocket Insets for the Oil & Gas Industry ata sheet S/I N Rev. eavy uty Pocket Insets Spare connection heads, extensions and measuring insets for resistance thermometers and thermocouples Thermometers in this range have been designed for use with

More information

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI Jetstream offers a wide variety of fittings with various connection types to fit your 20,000 psi application needs. The standard connection types, Type M, MP, and MP Tube lance, are available in standard

More information

TYPE 2800E EXTERNALLY MOUNTED, GAS LUBRICATED, NON-CONTACTING, DOUBLE CARTRIDGE SEAL

TYPE 2800E EXTERNALLY MOUNTED, GAS LUBRICATED, NON-CONTACTING, DOUBLE CARTRIDGE SEAL A Seat/Mating Ring B Face/Primary Ring (inboard) C Spring D Face/Primary Ring (outboard) E O-Ring F Drive Collar G Setting Ring H Sleeve TYPE 2800E B A D C H E Spiral Groove Technology G F Product Description

More information

EX-RECESSED CEILING LIGHT FITTINGS

EX-RECESSED CEILING LIGHT FITTINGS EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic

More information

Series MX pressure regulators 3/

Series MX pressure regulators 3/ CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges

More information

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L

Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

PRESSURE REGULATORS. Type B/240. Process Management TM

PRESSURE REGULATORS. Type B/240. Process Management TM PRESSURE REGULATORS Type B/240 Process Management TM B/240 Series Pressure Regulator The regulators of the B/240 series due to their operating specifications are mainly used in those system where sudden

More information

FLAMMABLE GAS SENSOR/TRANSMITTER

FLAMMABLE GAS SENSOR/TRANSMITTER FLAMMABLE GAS SENSOR/TRANSMITTER Plant safety protection for flammable gases. F E A T U R E S Fixed gas monitoring for point source hazards and perimeter protection in arduous duty and exposed locations.

More information

TYPE 7800 SERIES 7848D/7848W UNIVERSAL VESSEL SEAL Technical Specification

TYPE 7800 SERIES 7848D/7848W UNIVERSAL VESSEL SEAL Technical Specification A Face/Primary Ring B Seat/Mating Ring C O-ring D Disc E Sleeve F Retaining Sleeve D C E C F A B Product Description The Universal Vessel Seal 7800 Series is a modular cartridge seal for use in a wide

More information

Electro-Pneumatic Converter YT-940 SERIES

Electro-Pneumatic Converter YT-940 SERIES Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product

More information

Safety relief valves Type BSV-8

Safety relief valves Type BSV-8 Data sheet Safety relief valves Type BSV-8 BSV is a standard, back pressure independent safety relief valve, especially designed for protection of small components against excessive pressure and as a pilot

More information

Pressure control, differental pressure control and thermostat Type RT

Pressure control, differental pressure control and thermostat Type RT MAKING MODERN LIVING POSSIBLE Technical brochure Pressure control, differental pressure control and thermostat Type RT Hydrocarbons www.danfoss.com/hydrocarbons Contents Page Introduction...3 Approvals...3

More information

S.R.A. Fully Engineered Product Range

S.R.A. Fully Engineered Product Range Safety Roof Anchors S.R.A. Fully Engineered Product Range Issue 01.2017 www.safetyroofanchors.com.au S.R.A. Fully Engineered Product Range 400 Series Truss-T-Grip Profile Grip SRA Static Line Ladder Restraint

More information

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12 PN LINE PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN

More information

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New > Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,

More information

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY CERTIFICATE OF CONFORMITY No. ROSS US.GB05.V03061 Valid from 8/12/2010 through 8/12/2013 No. 0422555 CERTIFICATION AGENCY ROSS RU.0001.11GB05 NONPROFIT INDEPENDENT RESEARCH ORGANIZATION (), CERTIFICATION

More information

CMZ Series. Combination. FRZ Series. A combination to reliably remove water is now available!! ib-cyclone FRZ Series BK-P027- Filter regulator

CMZ Series. Combination. FRZ Series. A combination to reliably remove water is now available!! ib-cyclone FRZ Series BK-P027- Filter regulator BK-P27- ib-cyclone ib-cyclone FRZ Series Combination CMZ Series Water separator using high speed cyclone method New generation fi lter regulator FRZ Series IBCY4 IBCY5 FRZ4 FRZ5 A combination to reliably

More information

Quick Disconnect Torch Upgrade for Kaliburn Spirit & ProLine

Quick Disconnect Torch Upgrade for Kaliburn Spirit & ProLine Centricut Quick Disconnect Torch Upgrade for Kaliburn Spirit & ProLine Field Service Bulletin 808040 Revision 0 March 2013 Hypertherm, Inc. Etna Road, P.O. Box 5010 Hanover, NH 03755 USA 603-643-3441 Tel

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview High-pressure program as standard The sensor calibration factor is also valid for gas measurement. SITRANS FC00 is a compact Coriolis mass sensor suitable for flow measurement of a variety of

More information

Operating Instructions

Operating Instructions Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2

More information

Differential pressure

Differential pressure Differential pressure 9 Overview Page 200 VEGADIF 65 Page 202 Chemical seal Page 204 Accessory Page 208 199 VEGADIF For differential pressure, level and flow measurements Measuring principle The sensor

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

9700 Transmitter Submersible hydrostatic level transmitter

9700 Transmitter Submersible hydrostatic level transmitter Specification sheet IP0078 October 2007 Level 9700 Transmitter Submersible hydrostatic level transmitter Description The 9700 series hydrostatic level transmitter is designed to perform in the most arduous

More information

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification

TYPE ECS SEAL METAL BELLOWS DRY-RUNNING SECONDARY CONTAINMENT Technical Specification Low Temperature Design A Spacer Ring B Compression Ring C Retaining Ring D Wave Spring E O-ring F ent/drain Connection G Seat/Mating Ring H Insert I Bellows Assembly J Housing A K Spacer B F G H I C D

More information

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm

Relief Valves. Relief Valves. International, Inc. Company ACIRCOR. RS Differential NB 9.5mm. RVA In-line Differential NB 6 to 19mm s s RS Differential NB 9.5mm RVA In-line Differential NB 6 to 19mm RV Direct Acting NB up to 9mm LPR Low Pressure Differential NB 8mm We design, machine, build and test all our products on one site in

More information

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L. Contents Introduction.2 Standard cable glands - Plastic.5 Standard cable glands - Brass.7 EMC cable glands.14 Standard cable glands - Stainless steel.16 Cable glands for Ex applications - Brass.17 Adaptors.18

More information

Thermal flow sensor TA Di for separate evaluation units for measuring mass flow, standard flow rate and air or gas consumption.

Thermal flow sensor TA Di for separate evaluation units for measuring mass flow, standard flow rate and air or gas consumption. Thermal flow sensor TA Di for measuring mass flow, standard flow rate and air or gas consumption Drawing 4b Cable connection Sensor TA Di 8 Drawing 2b Cable connection Sensor TA Di 16... 41.8 Examples

More information

Osborne Engineering Limited. OEJ Equalised thrust bearing internals

Osborne Engineering Limited. OEJ Equalised thrust bearing internals Osborne Engineering Limited OEJ Equalised thrust bearing internals General Description The Osborne Equalised J style thrust bearing assembly operates by generating and maintaining a substantial oil film

More information

THREADED CONNECTORS TEMPERATURE: 300 F [150 C] Body Material/ Contact Material/ O-ring. Connector Contact Terminations

THREADED CONNECTORS TEMPERATURE: 300 F [150 C] Body Material/ Contact Material/ O-ring. Connector Contact Terminations THREADED CONNECTORS Suggested Mounting Detail For ed s TEMPERATURE: 300 F [150 C] Customer Bore 25000 0.312 0.308 #1/4-28 2500 5 #16 PIN X #22 CUP Body / Arlon 2000/ BeCu Gold Contact Mating 4805-063-002

More information

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X

Hydraulic comparison test pump Models CPP1000-X, CPP1600-X Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance

More information

NDE2 / NDH2 MOTORISED FURLERS. Comfort > Power > Reliability For boats from 9 to 22 m

NDE2 / NDH2 MOTORISED FURLERS. Comfort > Power > Reliability For boats from 9 to 22 m / NDH2 MOTORISED FURLERS Comfort > Power > Reliability For boats from 9 to 22 m The new motorised furlers from Profurl are the highlight of more than 30 years of experience in motorised sail furlers. These

More information

World Area Differences Technical Information

World Area Differences Technical Information World Area Differences Technical Information DMISC2047X02 This document is to give more information about the following: Porting & Threads Cleaning Procedures Conversion Tables PORTING & THREADS NPT (National

More information

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm Inductive Linear Displacement Transducers Model IW 260 Measuring strokes 80, 170, 240, 360 Document no. IW 100 HE Date 1.07.201 Contactless, robust sensor system Infinite resolution, no hysteresis Calibrated

More information

FUTURGAS VALVES. Components Pz. Materials

FUTURGAS VALVES. Components Pz. Materials UTURS VLVS 8 7 6 9 5 1 3 4 2 omponents Pz. Materials 1 ody 1 N 12165 W617N 2 nd connection 1 N 12165 W617N 3 all 1 N 12165 W617N 4 all seal 2 P.T... 5 Stem 1 N 12164 W614N 6 Rod seal O-Ring 2 NR 70 Sh

More information

VG5 Supplementary instructions

VG5 Supplementary instructions VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...

More information

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential Pressure Control Types MP 54, MP 55 and MP 55A MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration

More information

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH. M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 3603 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-60 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Dialight LED Conveyor Light - CE / RCM. for Indoor and Outdoor Industrial Applications

Dialight LED Conveyor Light - CE / RCM. for Indoor and Outdoor Industrial Applications Dialight LED Conveyor Light - CE / RCM for Indoor and Outdoor Industrial Applications Conveyor Light Products Vigilant LED Conveyor Light - CE / RCM Standard Model Mechanical Information: Fixture weight:

More information

RECTANGULAR CONNECTORS

RECTANGULAR CONNECTORS RECTANULAR CONNECTORS CN-360 SERIES EATURES Many applications Various connectors are available for connection by means of soldering, wire wrapping, crimping, PC board mounting, and insulation displacement

More information

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions

Specialists in HTM Medical Gas Pipeline Equipment AVSU/Module Operating and Maintenance Instructions The Area Value Service Units and Module format (AVSU) provide a local gas isolation facility for use during normal installation and maintenance or in the event of an emergency. They are built in accordance

More information

Differential pressure switch MP 54, MP 55 and MP 55A

Differential pressure switch MP 54, MP 55 and MP 55A Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating

More information

SERIES 3000 SERIES 3000 SWISS MADE EN-ID-1017

SERIES 3000 SERIES 3000 SWISS MADE EN-ID-1017 SERIES 000 SERIES 000 EN-ID-7 SWISS MADE BEST SOLUTION IN STAINLESS STEELS AND SUPER ALLOYS Chip evacuation Ø 0. -. mm SERIES 000 Double performance VX COATED Process security Ø. - 0 mm No sticking PERFORMANCE

More information

SCHRADER TANK VALVES FOR USE IN AIR BLADDER APPLICATIONS, BICYCLE SUSPENSION SYSTEMS, TELECOMMUNICATIONS, WATER STORAGE SYSTEMS, ETC.

SCHRADER TANK VALVES FOR USE IN AIR BLADDER APPLICATIONS, BICYCLE SUSPENSION SYSTEMS, TELECOMMUNICATIONS, WATER STORAGE SYSTEMS, ETC. SCHRADER TANK VALVES FOR USE IN AIR BLADDER APPLICATIONS, BICYCLE SUSPENSION SYSTEMS, TELECOMMUNICATIONS, WATER STORAGE SYSTEMS, ETC. Demand an authentic Schrader valve built by the company that set the

More information

Clean Speed Controller with One-touch Fitting

Clean Speed Controller with One-touch Fitting Clean Speed Controller with One-touch Fitting Series -FPQ/-FPG -FPG Series -FPQ Series Speed controllers for clean room use S R -FPQ: (electroless nickel plated) and -FPG: are now available as a series.

More information

Jamieson Equipment Company 5314 Palmero Court Buford, GA

Jamieson Equipment Company 5314 Palmero Court Buford, GA CONTENTS GENERAL INDUSTRIAL CONTROL VALVES...Page 3 HOW TO ORDER GOYEN MANUFACTURED VALVES...Page 4 Direct Lift...Page 5 Pilot Operated - Air, Water and Light Oil...Page 6 Pilot Operated Ô- Air or Gas...Page

More information

TYPE 7828G/7828GD 7800 SERIES UNIVERSAL VESSEL SEAL Technical Specification

TYPE 7828G/7828GD 7800 SERIES UNIVERSAL VESSEL SEAL Technical Specification A Face/Primary Ring B Seat/Mating Ring C O-Ring D Disc E Sleeve F Retaining Sleeve G Retaining Clip G D C E F C A B Patent numbers: 5,938,206 and 6,142,478 Product Description The universal vessel seal

More information

HI-PRESS HYDRAULICS Ltd

HI-PRESS HYDRAULICS Ltd -, Low Profile renches hown: units with interchangeable cassettes Rigid teel Design The Professional Low Profile olution implicity Includes handle to improve tool handling and safety. No tools are needed

More information

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846

CPVC Transition Fittings - Female Adapter. CPVC X LEAD FREE BRASS Lead Free Max working pressure F ASTM D 2846 CPVC Transition Fittings - Female Adapter STD4703BTLF12 1/2 CPVC X 1/2 FIP 25 250 CPVC Transition Fittings - Female Adapter STD4703BTLF34 3/4 CPVC X 3/4 FIP 25 250 CPVC Transition Fittings - Female Adapter

More information