1 ACCESSORIES HC RELAYS (Sockets and Terminal ) FEATURES. HC Relay Sockets In the table below, the suitable for each type of HC relay is indicated by a black dot. ) Plug-in type, type, and wrapping type are available for HC relays. ) Certified by UL and CSA ) A hold-down clip is included in the package.. HC Relay Terminal In the table below, the suitable for each type of HC relay is indicated by a black dot. ) Ordinary and for DIN rail assembly are available. ) Certified by UL/C-UL ) A hold-down clip is included in the package. The fixing method is the same as for HC, ordinary HC and HL. The fixing method is the same as for. The fixing method is the same as for the HC DIN rail HC/HL-LEAF-SPRING-MK Ordinary HC/HL-LEAF-SPRING-MK DIN rail Terminal HC-LEAF-SPRING-K SELECTOR CHART. Sockets Type No. of pole Product name Part No. Plug-in Wrapping Standard packing: Carton: 0 pcs.; Case: 00 pcs. Notes:. Use the hold-down clip that is shipped with the.. Certified by UL and CSA (except for wrapping ). (*) Please use with a max. carrying current no higher than A. Applicable HC relay (Plug-in type) Standard type/with diode type (for DC) Form C Form C Form C Form C Form C Amber type Form C Form C Form C Form C -pole HC- HC-SS-K -pole HC- HC-SS-K -pole HC- HC-SS-K //-pole (common) HC- HC-SS-K * * -pole HC- for HC-PS-K -pole HC- for HC-PS-K -pole HC- for HC-PS-K //-pole (common) HC- for HC-PS-K * * //-pole (common) HC-wrapping HC-WS-K * * HC-wrapping (spring) HC-WS * *. Terminal (HC Terminal ) Type No. of pole Item Part No. For DIN rail For general Standard packing Applicable HC relay (Plug-in type) Standard type/with diode type (for DC) Carton Case Form C Form C Form C Form C Form C Amber type Form C Form C Form C Form C -pole HC-slim type DIN HC-SFD-S 0 pcs. 00 pcs. /-pole HC-DIN HC-SFD-K pcs. 0 pcs. //-pole (common) HC vertical HC-TSF-K pcs. 0 pcs. * -pole HC- HC-SF-K 0 pcs. 00 pcs. /-pole HC-high HC-HSF-K pcs. 0 pcs. //-pole (common) HC-high HC-HSF-K pcs. 0 pcs. * Notes:. Use the hold-down clip that is shipped with the.. Certified by UL/C-UL (except for HC-TSF-K).. In order to prevent breakage and disfiguring, the screw tightening torque for the should be within the range of 0. to 0. N m { to kgf cm}. (*) Please use with a max. carrying current no higher than A. ASCTBE 00-T

2 . Terminal (HJ Terminal ) Type No. of pole Item Part No. For DIN rail -pole //-pole (common) Note: When using HJ-SFD/HJ-SFD-S with HC relay Form C/ Form C as a set, please keep the max. continuous current no higher than A. (*) Please use with a max. carrying current no higher than A. RATING Specifications (Sockets) Item Type Applicable HC relay (Plug-in type) Standard packing Standard type/with diode type (for DC) Amber type Carton Case Form C Form C Form C Form C Form C Form C HJ- HJ-SFD HJ- HJ-SFD-S (Finger protect type) 0 pcs. 00 pcs. HJ- HJ-SFD * HJ- HJ-SFD-S * (Finger protect type) HC HC HC HC Performance HC HC HC HC Contact arrangement Form C (-pole) Form C (-pole) Form C (/-pole common) Form C (//-pole common) Max. continuous current (Ambient temperature: -0 to +0 C - to + F) 0A 0A A A A A A A Breakdown voltage (Initial) Between open contacts sets and coil, 000 Vrms for min. (Detection current: 0mA) Initial insulation resistance 00 MΩ between each (00V DC) Note: When using / pole HC relay (0A, A rating) on a Form C that is //-pole common, please use within a range that does not exceed the max. continuous current (A). Specifications (Terminal ) Item Type HC-slim HC HC For general HC Performance HC-high For general HC-high HC-high vertical type HC For general Contact arrangement Form C (-pole) Form C (/-pole common) Form C (//-pole common) Max. continuous current (Ambient temperature: -0 to +0 C - to + F) A A A A A A A A Breakdown voltage (Initial) Between open contacts sets and coil, 000 Vrms for min. (Detection current: 0mA) Initial insulation resistance 00 MΩ between each (00V DC) Note: When using a -pole HC relay (0A) on Form C that is //-pole common, please use within a range that does not exceed the max. continuous current (A). ASCTBE 00-T

3 DIMENSIONS (mm inch). Plug-in type HC-Socket (HC-SS-K) The CAD data of the products with a mark can be downloaded from: HC-Socket (HC-SS-K) General tolerance: ±0. ±.0..0 General tolerance: ±0. ±.0..0 HC-Socket (HC-SS-K) HC-Socket (HC-SS-K) General tolerance: ±0. ±.0..0 General tolerance: ±0. ±.0..0 Side-by-side installation With a relay mounted (HC-SS-K) General tolerance: ±0. ±.00 Notes:. Applicable chassis board thickness is.0 to.0 mm.. Installation is easy by inserting the from the top into the holes and by depressing the two down arrows on the retention fitting from the front. Hold-down clip is packaged with the. ASCTBE 00-T

4 . type HC- type (HC-PS-K) HC- type (HC-PS-K) General tolerance: ±0. ±.0.. General tolerance: ±0. ±.0.. HC- type (HC-PS-K) HC- type (HC-PS-K) General tolerance: ±0. ±.0 pattern (Bottom view) With a relay mounted General tolerance: ±0. ±.0.. Side-by-side installation.. Hold-down clip is packaged with the...0 Form C Form C Form C Form C dia. hole -.0 dia. - dia. hole -.0 dia. - dia. hole -.0 dia dia. hole -.0 dia... General tolerance: ±0. ±.00 dia. hole.0 dia. ASCTBE 00-T

5 . Wrapping type Standard wrapping type (HC-WS-K)..00.0±0..0±.00 Hold-down clip (Hold-down clip is packaged with the ) Terminal cross section ±0..0±.00.0±0..0±.00 ±0.0.0±.00 General tolerance: ±0. ±.0 Note: The external and mounting dimensions are the same for -pole (HC-WS-K), -pole (HC-WS-K), and -pole (HC-WS-K) types. Only the number of s varies. Wrapping type with hold-down clip (HC-WS) Terminal cross section ±0..0±.00.0 ±0.0.0± General tolerance: ±0. ±.0 Side-by-side installation General tolerance: ±0. ±.00 Notes:. Applicable chassis board thickness is.0 to.0 mm.. Installation is easy by inserting the from the top into the holes and by depressing the two down arrows on the retention fitting from the front. ASCTBE 00-T

6 . DIN rail Terminal HC-Slim type DIN rail (HC-SFD-S) ±0..±.0 ±0. ±.00 M. screw 0±0..±.0 N.C. N.O..±0..±.00.±0..±.00.±0..±.00 ±0..0±.00 ±.±.0 ±0..±.00.±0..±.0 ±.±.0.±0..±.00 COM. ±0..±.0.±0..±.0.±0..±.0 ±0..±.0 General tolerance: ±0. ±.00 Coil HC-high DIN rail (HC-SFD-K) ±0..0±.0 M. screw.±0..±.0 N.C. N.O. ±0. ±.00 ±0. ±.00 ±0. ±.00.±0..00±.00.±0..±.0 ±.±.0 COM.. 0±0..±.0 Coil General tolerance: ±0. ±.00 HC vertical type (HC-TSF-K) -. over hole -.. ±0..±.0 M. screw.±0..±.0 ±.±.0 ±.± ±0..±.0 General tolerance: ±0. ±.00 HC-Slim type HC, HC and HC HC vertical type 0.. ±0. ±0..±.00.± M. screw hole. (or.±0. dia. hole) ±0. -M. screw hole.±.00 (or.±.00 dia. hole)... Panel hole dimensions for side-by-side mounting... -M. screw hole (or.±0. dia. hole) -M. screw hole (or.±.00 dia. hole) Panel hole dimensions for side-by-side mounting -M. screw hole (or.±0. dia. hole) -M. screw hole (or.±.00 dia. hole) General tolerance: ±0. ±.00 ASCTBE 00-T

7 . Ordinary HC- (HC-SF-K for HC) -. over hole M. screw General tolerance: ±0. ±.00 HC-high (HC-HSF-K) suitable for both HC and HC -. over hole M. screw Screw hole dimensions General tolerance: ±0. ±.00 HC-high (HC-HSF-K) suitable for HC, and -. over hole M. screw Screw hole dimensions General tolerance: ±0. ±.00 HC-SF-K HC-HSF-K and HC-HSF-K With a relay mounted (HC-SF-K) Panel hole dimensions for side-by-side mounting -M. screw hole (or.±0. dia. hole) -M. screw hole (or.±.00 dia. hole) Panel hole dimensions for side-by-side mounting..0. -M. screw hole (or.±0. dia. hole) -M. screw hole (or.±.00 dia. hole) General tolerance: ±0. ±.00 Hold-down clip is packaged with the. ASCTBE 00-T

TURQUOISE SWITCHES ABJ (BJ) SWITCHES

TURQUOISE SWITCHES ABJ (BJ) SWITCHES Ultra-miniature Size Sealed Switches TURQUOISE SWITCHES ABJ (BJ) SWITCHES Terminal type Mounting hole 2.3 mm type FEATURES Ultra-miniature size, High sealing performance sealed switches Elastomer double

More information

Zelio Relays RSL Slim Interface Plug-In Relays

Zelio Relays RSL Slim Interface Plug-In Relays Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3

More information

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11 Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double

More information

(Track-mounting) *see page 243. *see page 246 Screw terminal Solder terminal PCB terminal Screw terminal P2RF-05-E Approx. 38 g. P2R-05P Approx.

(Track-mounting) *see page 243. *see page 246 Screw terminal Solder terminal PCB terminal Screw terminal P2RF-05-E Approx. 38 g. P2R-05P Approx. Square Item 5 pins P2RF-05 Approx. 27 g P2RF (Track-mounting) *see page 243 P2R *see page 246 P7TF (Track-mounting) *see page 246 Screw Solder PCB Screw P2RF-05-E Approx. 38 g P2R-05A Approx. 5 g P2R-05P

More information

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal

More information

COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW

COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW JUN 200 CONTENTS: SECTION TITLE PAGE Description of Connector and Intended Application 2 2 Marking of Connector and/or Package 2 3 Ratings

More information

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

Miniature controls. Contactors. Overload relays. Starters. Control relays

Miniature controls. Contactors. Overload relays. Starters. Control relays Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power

More information

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts:

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts: HBE Series HBE series inserts provide reliable termination and performance in the vast majority of medium power and control applications. Methods of termination include screw, crimp, and spring cage clamp.

More information

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical

More information

General-purpose Relays and Power Relays Sockets

General-purpose Relays and Power Relays Sockets General-purpose Relays and Power Relays Sockets Relay Type Track Mount Sockets Back Connecting Sockets Solder terminals PCB terminals G2R-1-S P2RF-05 P2RF-05-E P2RF-05-S P2R-05A P2R-05P G2R-2-S P2RF-08

More information

Pressure switch for gas and air

Pressure switch for gas and air Pressure switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF GXX_A4

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more

More information

Pressure Switch for gas and air GGAO-A4

Pressure Switch for gas and air GGAO-A4 Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. 13 and No. 0 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit

More information

Conductor Bushings Series 8174

Conductor Bushings Series 8174 > Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

Compact pressure switches for gas and air

Compact pressure switches for gas and air Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The

More information

MDM Accessories

MDM Accessories Accessories General Hardwares are the screwlock assemblies or the brackets used for the mounting of connectors on panels or PC, or for the fixing of plugs and receptacles. They are not fixed on the connectors

More information

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

References 6 k thermal overload relays, adjustable from 0.11 to 16 A s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure

More information

A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure

A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure Master Catalog 125 Temperature Controls Section A Product Bulletin A28 Issue Date 0618 A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure Application These two-stage controls are designed

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Pressure Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL File # MH 668 CSA Certified CSA C. No. LR File # 07 FM Approved Class 0, 0 File # J.I. Y9A9.AF Commonwealth of Massachusetts

More information

OTL Universal terminals

OTL Universal terminals OTL Universal terminals 2019 Universal terminals OTL Universal terminals OTL 1000 V AC/DC Bimetal (AL/CU) Class A Certified according to standards EN 612381 and EN 6094771 2 Universal terminals OTL Universal

More information

Solenoid Valves VUVG Overview

Solenoid Valves VUVG Overview Solenoid Valves VUVG Overview Universal valve Combination of basic valve and E-boxes Width 10 mm and 14 mm In-line valves VUVG-L and VUVG-S Sub-base valves VUVG-B Internal or external pilot air supply

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

QPL... Pressure Switches. Siemens Building Technologies HVAC Products 7 221 Pressure Switches QPL... The pressure switches are used for monitoring gas or air pressures. When the pressure falls below the switching point, the associated electrical circuit will open or switch

More information

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments

ARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments ARCA cabinet NEW High performance polycarbonate cabinet Protection in demanding environments NEW Fibox ARCA Fibox ARCA non corrosive electrical cabinets for use in extremely harsh and demanding environments

More information

Expert Hydrostatic Level Transmitters

Expert Hydrostatic Level Transmitters Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level

More information

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119 Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,

More information

Amphenol RF. Type N. Type N Connectors. Type N. Description. Features/Benefits. Applications

Amphenol RF. Type N. Type N Connectors. Type N. Description. Features/Benefits. Applications Amphenol RF 144 Connectors Description Named after Paul Neill of Bell Labs after being developed in the 1940 s, the offered the first true microwave performance. The connector was developed to satisfy

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

Types and approvals. Page 1/6. Data Sheet

Types and approvals. Page 1/6. Data Sheet Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description

More information

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400 MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile 2.75 GB 2.75 Expert 090311 We reserve the right to continuously improve our products and make

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Actuating elements for ComEx

Actuating elements for ComEx Description A large number of variants and versions of actuating elements are available for the ComEx control and indicator units. All actuating elements are made of high-quality thermoplastic and conform

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

NO: REL-149 PRODUCT: G8P Series PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice

NO: REL-149 PRODUCT: G8P Series PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice NO: REL-149 PRODUCT: PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice G8P PCB Power Relays to be DISCONTINUED April 30, 2015 Due to a diminishing global demand for the G8P series PCB Power

More information

TeSys protection components

TeSys protection components Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION 2/2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32 Size 32 up to 42 MPa 700 dm 3 /min WK 490 907 04.1999r. 2/2 way cartridge valve type URZS 32 can be used to build hydraulic systems

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS 36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING

More information

ComEx Actuating elements

ComEx Actuating elements ComEx Actuating elements for Zone and 2 ComEx Actuating elements Features Easy installation Certified for Zone and 2 High IP degree of protection A large number of variants and versions of actuating elements

More information

Pneumatic valve islands

Pneumatic valve islands Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented

More information

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA HPSV 10020/604 High Pressure Safety Shutoff Valve Installation Instructions USA CDN Table of Contents Table of Contents...Page 1 Approvals...Page 1 Attention...Page 1 Specification...Page 2 Installation

More information

Pressure switch Type BCP

Pressure switch Type BCP Data sheet Pressure switch Type BCP The BCP type is a series of dedicated switches for safety and monitoring of steam and hot water boilers. The BCP incorporates a single-pole changeover microswitch where

More information

Datamate Specification. Pin Numbering. Mating Profiles. Materials. Mechanical. 3 Row 6.

Datamate Specification. Pin Numbering. Mating Profiles. Materials. Mechanical. 3 Row 6. Datamate Specification Materials Mechanical Mouldings: Glass-filled thermoplastic UL94V-0 Female contacts: rass shell, with eryllium opper inner contact Male contacts: Phosphor bronze Finish: See individual

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

EPP4 Pressure Regulator Basic G 1/4"

EPP4 Pressure Regulator Basic G 1/4 EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

Pegasus Series Amphenol Pcd

Pegasus Series Amphenol Pcd Pegasus Series Amphenol Pcd Amphenol Pcd is one of the world s leading suppliers of interconnect products for Military, Commercial Aerospace and Industrial applications. Located north of Boston in Beverly,

More information

Mass Flow Meter (MFM) for gases

Mass Flow Meter (MFM) for gases Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Limit switches OsiSense XC Special For material handling applications, type XC1 AC Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics

More information

X2 Metallized Polypropylene Film Capacitor JFV

X2 Metallized Polypropylene Film Capacitor JFV FEATURES: Non-inductive, (UL940V-0) plastic case sealed with epoxy resin. Provides interference suppression with VDE, ENEC and UL approvals. SPECIFICATIONS: Operating Temperature -40 ~ +110 Voltage Rating

More information

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3. Installation Instructions manual MUELLER table of contents PAGE A-20806 A-20807 Adjustable General Information 2 Technical Data 3 Dimensions 4 Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator

More information

POWR-BLOKS Distribution/Splicer Blocks and Covers

POWR-BLOKS Distribution/Splicer Blocks and Covers SPECIFICATIONS Voltage : 600V erage: Based on NEC Table 310-16, using 75 C copper wire Material: Phenolic rated at 150 C and Thermoplastic rated at 125 C (LD1400 and LS1300 series only) : Standard: Highly

More information

TECHNICAL CHARACTERSTICS

TECHNICAL CHARACTERSTICS and solenoid valves spool version GM - GL series Type of valves with dorsal consumption: GM-...series with integrated connections GL-...series without connections TECHNICAL CHARACTERSTICS Ambient temperature:

More information

38999 Space grade ESA/SCC Section. MIL-DTL Space Grade Circular Connectors

38999 Space grade ESA/SCC Section. MIL-DTL Space Grade Circular Connectors 38999 Space grade ESA/SCC 3401 Section II MI-DT 38999 Space Grade Circular Connectors 59 38999 Space Grade ESA/SCC 3401 Contents 38999 Space Grade ESA/SCC 3401 SCC Specification.......................................................61

More information

Electric expansion valves Types AKV 10, AKV 15 and AKV 20

Electric expansion valves Types AKV 10, AKV 15 and AKV 20 Data sheet Electric expansion valves Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV valves are normally controlled by a controller

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTRUCTION MANUAL Pressure Relief Device LPT INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

powr-bloks POWR-GARD Fuseblocks Distribution/Splicer Blocks and Covers Applications Connectors Description Ampere Ratings Specifications

powr-bloks POWR-GARD Fuseblocks Distribution/Splicer Blocks and Covers Applications Connectors Description Ampere Ratings Specifications powr-bloks Applications Typical applications include heating, air conditioning and refrigeration systems, el e va tor systems, material handling equipment, control panels, motor controls, switchgear, and

More information

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version 2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for

More information

Installation, use and maintenance instructions. Gas burner (5)

Installation, use and maintenance instructions. Gas burner (5) Installation, use and maintenance instructions Gas burner MODEL GAS 4 TYPE 516 T80 291 (5) TECHNICAL FEATURES Thermal output 180-470 kw 154.800-404.200 kcal/h Fuel Natural gas Pci 8-10 kwh/m 3 = 7000-8600

More information

Electrical Sensing Edges

Electrical Sensing Edges sensing the future Electrical Sensing Edges Electrical sensing edges for safeguarding machinery & robots, automatic doors & gates, and public transportation Reliable, proven, long lasting Wide variety

More information

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17 TABLE OF CONTENTS MAIDA S HISTORY TERMINOLOGY & GENERAL LEAD CODES and TAPE & REEL i ii iii STANDARD SERIES 1 HC SERIES 17 LOW PROFILE SERIES 33 THERMALLY PROTECTED SERIES 39 HIGH ENERGY SERIES LEAD CODES

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 9 5 14 40 35 11 9 5.4 M20 x 1.5 0102 S Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

SPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at:

SPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at: SPOOL VLVS ISO 07/ - Sizes 0-0 Series 8-9 P68-GB-R ll leafl ets available at: www.ascojoucomatic.com FTURS These spool valves which comply with the VDM 6 standard offer the advantage of being smaller than

More information

User Manual V14.1 IP68 LED FLEX NEON

User Manual V14.1 IP68 LED FLEX NEON User Manual V14.1 IP68 LED FLEX NEON PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE END USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE 1/11 PRODUCT SPECIFICATION 1. Operating

More information

EPIC Rectangular Connectors HBE Series

EPIC Rectangular Connectors HBE Series HBE Series The HBE series inserts are suitable for applications with high voltages and current. The inserts can be terminated in a variety of ways: screw, crimp, or spring cage clamp. TECHNICAL DATA Number

More information

RECTANGULAR CONNECTORS

RECTANGULAR CONNECTORS RECTANULAR CONNECTORS CN-360 SERIES EATURES Many applications Various connectors are available for connection by means of soldering, wire wrapping, crimping, PC board mounting, and insulation displacement

More information

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008 INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008 0376/448/00 ISSUE 01 EMERGENCY PUSH PAD PULLMAN BOLT DEVICE TO EN 179 : 2008 1000mm MAXIMUM CLEAR OPENING HEIGHT WITH PUSH

More information

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

E3G-L1/L3. Effectively Cuts the Influence of Workpiece Characteristics, Such as Gloss, Incline, and Color. Distance-setting Photoelectric Sensor

E3G-L1/L3. Effectively Cuts the Influence of Workpiece Characteristics, Such as Gloss, Incline, and Color. Distance-setting Photoelectric Sensor Distance-setting Photoelectric EG-L/L CSM_EG-L_L_DS_E Effectively Cuts the Influence of Workpiece Characteristics, Such as Gloss, Incline, and Color. Be sure to read Safety Precautions on page. Features

More information

Available models Devices Color White sealing bellows Black sealing bellows NDT SW NDT GB NDT RT NDT GN NDT WS NDT BL NDT GR

Available models Devices Color White sealing bellows Black sealing bellows NDT SW NDT GB NDT RT NDT GN NDT WS NDT BL NDT GR Pushbuttons Left: type series N with sealing bellows, color white (standard). Right: type series N with sealing bellows, color black. Protective collar against unintentional actuation: refer to page 58

More information

IP65 Air Differential Pressure Switch

IP65 Air Differential Pressure Switch Page 1 of 5 PA-DPS-9x IP65 Air Differential Pressure Switch Features: Benefits: Close switching differential IP65 Housing Duct fixing kit included Switching point easily adjusted with scale in One screw

More information

Pressure switches for air and water CS

Pressure switches for air and water CS Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the

More information

RPS900W Redundant Power Supply. Installation Guide.

RPS900W Redundant Power Supply. Installation Guide. RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A

More information

RG2 Gripper Datasheet Version 1.6

RG2 Gripper Datasheet Version 1.6 RG2 Gripper Datasheet Version 1.6 The RG2 gripper is a flexible electric gripper specially designed for robots from Universal Robots. The long stroke allows the gripper to handle a variety of object sizes.

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is

More information

OPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson

OPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson Page 1 (6) Our Ref: PSE, Bernt Andersson OPTIPOW 105 OPTIPOW 105, the compact pulse valve for the Optipulse fabric filters of different types: is a result of many years of experiences within the fabric

More information

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents

More information

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1. > Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to

More information

SERIES A24 RAISED RIB

SERIES A24 RAISED RIB SERIES A24 RAISED RIB Eurobelt Series A24 Raised Rib conveyor belt has been designed mainly to be used with finger plates. It has ribs that, sticking out 6 mm above the module, provide a greater resistance

More information

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual

Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents Section I. Installing Light Fixture

More information

MMCX Coaxial Connectors

MMCX Coaxial Connectors The Amphenol MMCX series is the next generation of microminiature connectors. Offering a reliable broadband performance from DC to 6 GHz. These 50 ohm connectors incorporate the industryapproved MMCX interface,

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

Parallel grippers HGPM, micro

Parallel grippers HGPM, micro Key features G6: G8: G9: stroke compensation clamping spigot flange mounting At a glance Compact, handy design With open or closed gripper jaws Versatility thanks to externally adaptable gripper fingers

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information