1 ACCESSORIES HC RELAYS (Sockets and Terminal ) FEATURES. HC Relay Sockets In the table below, the suitable for each type of HC relay is indicated by a black dot. ) Plug-in type, type, and wrapping type are available for HC relays. ) Certified by UL and CSA ) A hold-down clip is included in the package.. HC Relay Terminal In the table below, the suitable for each type of HC relay is indicated by a black dot. ) Ordinary and for DIN rail assembly are available. ) Certified by UL/C-UL ) A hold-down clip is included in the package. The fixing method is the same as for HC, ordinary HC and HL. The fixing method is the same as for. The fixing method is the same as for the HC DIN rail HC/HL-LEAF-SPRING-MK Ordinary HC/HL-LEAF-SPRING-MK DIN rail Terminal HC-LEAF-SPRING-K SELECTOR CHART. Sockets Type No. of pole Product name Part No. Plug-in Wrapping Standard packing: Carton: 0 pcs.; Case: 00 pcs. Notes:. Use the hold-down clip that is shipped with the.. Certified by UL and CSA (except for wrapping ). (*) Please use with a max. carrying current no higher than A. Applicable HC relay (Plug-in type) Standard type/with diode type (for DC) Form C Form C Form C Form C Form C Amber type Form C Form C Form C Form C -pole HC- HC-SS-K -pole HC- HC-SS-K -pole HC- HC-SS-K //-pole (common) HC- HC-SS-K * * -pole HC- for HC-PS-K -pole HC- for HC-PS-K -pole HC- for HC-PS-K //-pole (common) HC- for HC-PS-K * * //-pole (common) HC-wrapping HC-WS-K * * HC-wrapping (spring) HC-WS * *. Terminal (HC Terminal ) Type No. of pole Item Part No. For DIN rail For general Standard packing Applicable HC relay (Plug-in type) Standard type/with diode type (for DC) Carton Case Form C Form C Form C Form C Form C Amber type Form C Form C Form C Form C -pole HC-slim type DIN HC-SFD-S 0 pcs. 00 pcs. /-pole HC-DIN HC-SFD-K pcs. 0 pcs. //-pole (common) HC vertical HC-TSF-K pcs. 0 pcs. * -pole HC- HC-SF-K 0 pcs. 00 pcs. /-pole HC-high HC-HSF-K pcs. 0 pcs. //-pole (common) HC-high HC-HSF-K pcs. 0 pcs. * Notes:. Use the hold-down clip that is shipped with the.. Certified by UL/C-UL (except for HC-TSF-K).. In order to prevent breakage and disfiguring, the screw tightening torque for the should be within the range of 0. to 0. N m { to kgf cm}. (*) Please use with a max. carrying current no higher than A. ASCTBE 00-T
2 . Terminal (HJ Terminal ) Type No. of pole Item Part No. For DIN rail -pole //-pole (common) Note: When using HJ-SFD/HJ-SFD-S with HC relay Form C/ Form C as a set, please keep the max. continuous current no higher than A. (*) Please use with a max. carrying current no higher than A. RATING Specifications (Sockets) Item Type Applicable HC relay (Plug-in type) Standard packing Standard type/with diode type (for DC) Amber type Carton Case Form C Form C Form C Form C Form C Form C HJ- HJ-SFD HJ- HJ-SFD-S (Finger protect type) 0 pcs. 00 pcs. HJ- HJ-SFD * HJ- HJ-SFD-S * (Finger protect type) HC HC HC HC Performance HC HC HC HC Contact arrangement Form C (-pole) Form C (-pole) Form C (/-pole common) Form C (//-pole common) Max. continuous current (Ambient temperature: -0 to +0 C - to + F) 0A 0A A A A A A A Breakdown voltage (Initial) Between open contacts sets and coil, 000 Vrms for min. (Detection current: 0mA) Initial insulation resistance 00 MΩ between each (00V DC) Note: When using / pole HC relay (0A, A rating) on a Form C that is //-pole common, please use within a range that does not exceed the max. continuous current (A). Specifications (Terminal ) Item Type HC-slim HC HC For general HC Performance HC-high For general HC-high HC-high vertical type HC For general Contact arrangement Form C (-pole) Form C (/-pole common) Form C (//-pole common) Max. continuous current (Ambient temperature: -0 to +0 C - to + F) A A A A A A A A Breakdown voltage (Initial) Between open contacts sets and coil, 000 Vrms for min. (Detection current: 0mA) Initial insulation resistance 00 MΩ between each (00V DC) Note: When using a -pole HC relay (0A) on Form C that is //-pole common, please use within a range that does not exceed the max. continuous current (A). ASCTBE 00-T
3 DIMENSIONS (mm inch). Plug-in type HC-Socket (HC-SS-K) The CAD data of the products with a mark can be downloaded from: HC-Socket (HC-SS-K) General tolerance: ±0. ±.0..0 General tolerance: ±0. ±.0..0 HC-Socket (HC-SS-K) HC-Socket (HC-SS-K) General tolerance: ±0. ±.0..0 General tolerance: ±0. ±.0..0 Side-by-side installation With a relay mounted (HC-SS-K) General tolerance: ±0. ±.00 Notes:. Applicable chassis board thickness is.0 to.0 mm.. Installation is easy by inserting the from the top into the holes and by depressing the two down arrows on the retention fitting from the front. Hold-down clip is packaged with the. ASCTBE 00-T
4 . type HC- type (HC-PS-K) HC- type (HC-PS-K) General tolerance: ±0. ±.0.. General tolerance: ±0. ±.0.. HC- type (HC-PS-K) HC- type (HC-PS-K) General tolerance: ±0. ±.0 pattern (Bottom view) With a relay mounted General tolerance: ±0. ±.0.. Side-by-side installation.. Hold-down clip is packaged with the...0 Form C Form C Form C Form C dia. hole -.0 dia. - dia. hole -.0 dia. - dia. hole -.0 dia dia. hole -.0 dia... General tolerance: ±0. ±.00 dia. hole.0 dia. ASCTBE 00-T
5 . Wrapping type Standard wrapping type (HC-WS-K)..00.0±0..0±.00 Hold-down clip (Hold-down clip is packaged with the ) Terminal cross section ±0..0±.00.0±0..0±.00 ±0.0.0±.00 General tolerance: ±0. ±.0 Note: The external and mounting dimensions are the same for -pole (HC-WS-K), -pole (HC-WS-K), and -pole (HC-WS-K) types. Only the number of s varies. Wrapping type with hold-down clip (HC-WS) Terminal cross section ±0..0±.00.0 ±0.0.0± General tolerance: ±0. ±.0 Side-by-side installation General tolerance: ±0. ±.00 Notes:. Applicable chassis board thickness is.0 to.0 mm.. Installation is easy by inserting the from the top into the holes and by depressing the two down arrows on the retention fitting from the front. ASCTBE 00-T
6 . DIN rail Terminal HC-Slim type DIN rail (HC-SFD-S) ±0..±.0 ±0. ±.00 M. screw 0±0..±.0 N.C. N.O..±0..±.00.±0..±.00.±0..±.00 ±0..0±.00 ±.±.0 ±0..±.00.±0..±.0 ±.±.0.±0..±.00 COM. ±0..±.0.±0..±.0.±0..±.0 ±0..±.0 General tolerance: ±0. ±.00 Coil HC-high DIN rail (HC-SFD-K) ±0..0±.0 M. screw.±0..±.0 N.C. N.O. ±0. ±.00 ±0. ±.00 ±0. ±.00.±0..00±.00.±0..±.0 ±.±.0 COM.. 0±0..±.0 Coil General tolerance: ±0. ±.00 HC vertical type (HC-TSF-K) -. over hole -.. ±0..±.0 M. screw.±0..±.0 ±.±.0 ±.± ±0..±.0 General tolerance: ±0. ±.00 HC-Slim type HC, HC and HC HC vertical type 0.. ±0. ±0..±.00.± M. screw hole. (or.±0. dia. hole) ±0. -M. screw hole.±.00 (or.±.00 dia. hole)... Panel hole dimensions for side-by-side mounting... -M. screw hole (or.±0. dia. hole) -M. screw hole (or.±.00 dia. hole) Panel hole dimensions for side-by-side mounting -M. screw hole (or.±0. dia. hole) -M. screw hole (or.±.00 dia. hole) General tolerance: ±0. ±.00 ASCTBE 00-T
7 . Ordinary HC- (HC-SF-K for HC) -. over hole M. screw General tolerance: ±0. ±.00 HC-high (HC-HSF-K) suitable for both HC and HC -. over hole M. screw Screw hole dimensions General tolerance: ±0. ±.00 HC-high (HC-HSF-K) suitable for HC, and -. over hole M. screw Screw hole dimensions General tolerance: ±0. ±.00 HC-SF-K HC-HSF-K and HC-HSF-K With a relay mounted (HC-SF-K) Panel hole dimensions for side-by-side mounting -M. screw hole (or.±0. dia. hole) -M. screw hole (or.±.00 dia. hole) Panel hole dimensions for side-by-side mounting..0. -M. screw hole (or.±0. dia. hole) -M. screw hole (or.±.00 dia. hole) General tolerance: ±0. ±.00 Hold-down clip is packaged with the. ASCTBE 00-T
TURQUOISE SWITCHES ABJ (BJ) SWITCHES
Ultra-miniature Size Sealed Switches TURQUOISE SWITCHES ABJ (BJ) SWITCHES Terminal type Mounting hole 2.3 mm type FEATURES Ultra-miniature size, High sealing performance sealed switches Elastomer double
More informationZelio Relays RSL Slim Interface Plug-In Relays
Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3
More informationSocket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11
Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double
More information(Track-mounting) *see page 243. *see page 246 Screw terminal Solder terminal PCB terminal Screw terminal P2RF-05-E Approx. 38 g. P2R-05P Approx.
Square Item 5 pins P2RF-05 Approx. 27 g P2RF (Track-mounting) *see page 243 P2R *see page 246 P7TF (Track-mounting) *see page 246 Screw Solder PCB Screw P2RF-05-E Approx. 38 g P2R-05A Approx. 5 g P2R-05P
More informationThe Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal
More informationCOMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW
COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW JUN 200 CONTENTS: SECTION TITLE PAGE Description of Connector and Intended Application 2 2 Marking of Connector and/or Package 2 3 Ratings
More informationTANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR
SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationMiniature controls. Contactors. Overload relays. Starters. Control relays
Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power
More informationEPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts:
HBE Series HBE series inserts provide reliable termination and performance in the vast majority of medium power and control applications. Methods of termination include screw, crimp, and spring cage clamp.
More informationCONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES
I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical
More informationGeneral-purpose Relays and Power Relays Sockets
General-purpose Relays and Power Relays Sockets Relay Type Track Mount Sockets Back Connecting Sockets Solder terminals PCB terminals G2R-1-S P2RF-05 P2RF-05-E P2RF-05-S P2R-05A P2R-05P G2R-2-S P2RF-08
More informationPressure switch for gas and air
Pressure switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF GXX_A4
More informationMeta-MEC Manual Motor Starters
www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more
More informationPressure Switch for gas and air GGAO-A4
Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. 13 and No. 0 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationPRODUCT SPECIFICATION
MINI-FIT SR. SERIES 1.0 SCOPE This specification covers the 10.00 mm / (.394 in.) centerline tin and gold plated connector series, single and dual row versions in wire to wire and wire to printed circuit
More informationConductor Bushings Series 8174
> Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
More informationCompact pressure switches for gas and air
Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The
More informationMDM Accessories
Accessories General Hardwares are the screwlock assemblies or the brackets used for the mounting of connectors on panels or PC, or for the fixing of plugs and receptacles. They are not fixed on the connectors
More informationReferences 6 k thermal overload relays, adjustable from 0.11 to 16 A
s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure
More informationA28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure
Master Catalog 125 Temperature Controls Section A Product Bulletin A28 Issue Date 0618 A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure Application These two-stage controls are designed
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Pressure Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL File # MH 668 CSA Certified CSA C. No. LR File # 07 FM Approved Class 0, 0 File # J.I. Y9A9.AF Commonwealth of Massachusetts
More informationOTL Universal terminals
OTL Universal terminals 2019 Universal terminals OTL Universal terminals OTL 1000 V AC/DC Bimetal (AL/CU) Class A Certified according to standards EN 612381 and EN 6094771 2 Universal terminals OTL Universal
More informationSolenoid Valves VUVG Overview
Solenoid Valves VUVG Overview Universal valve Combination of basic valve and E-boxes Width 10 mm and 14 mm In-line valves VUVG-L and VUVG-S Sub-base valves VUVG-B Internal or external pilot air supply
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More informationQPL... Pressure Switches. Siemens Building Technologies HVAC Products
7 221 Pressure Switches QPL... The pressure switches are used for monitoring gas or air pressures. When the pressure falls below the switching point, the associated electrical circuit will open or switch
More informationARCA cabinet NEW. High performance polycarbonate cabinet. Protection in demanding environments
ARCA cabinet NEW High performance polycarbonate cabinet Protection in demanding environments NEW Fibox ARCA Fibox ARCA non corrosive electrical cabinets for use in extremely harsh and demanding environments
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationData sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119
Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,
More informationAmphenol RF. Type N. Type N Connectors. Type N. Description. Features/Benefits. Applications
Amphenol RF 144 Connectors Description Named after Paul Neill of Bell Labs after being developed in the 1940 s, the offered the first true microwave performance. The connector was developed to satisfy
More informationE2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information
Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.
More informationTypes and approvals. Page 1/6. Data Sheet
Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description
More informationMJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400
MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile 2.75 GB 2.75 Expert 090311 We reserve the right to continuously improve our products and make
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationActuating elements for ComEx
Description A large number of variants and versions of actuating elements are available for the ComEx control and indicator units. All actuating elements are made of high-quality thermoplastic and conform
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationNO: REL-149 PRODUCT: G8P Series PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice
NO: REL-149 PRODUCT: PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice G8P PCB Power Relays to be DISCONTINUED April 30, 2015 Due to a diminishing global demand for the G8P series PCB Power
More informationTeSys protection components
Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationWK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION
2/2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32 Size 32 up to 42 MPa 700 dm 3 /min WK 490 907 04.1999r. 2/2 way cartridge valve type URZS 32 can be used to build hydraulic systems
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More information36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS
36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING
More informationComEx Actuating elements
ComEx Actuating elements for Zone and 2 ComEx Actuating elements Features Easy installation Certified for Zone and 2 High IP degree of protection A large number of variants and versions of actuating elements
More informationPneumatic valve islands
Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented
More informationO.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA
HPSV 10020/604 High Pressure Safety Shutoff Valve Installation Instructions USA CDN Table of Contents Table of Contents...Page 1 Approvals...Page 1 Attention...Page 1 Specification...Page 2 Installation
More informationPressure switch Type BCP
Data sheet Pressure switch Type BCP The BCP type is a series of dedicated switches for safety and monitoring of steam and hot water boilers. The BCP incorporates a single-pole changeover microswitch where
More informationDatamate Specification. Pin Numbering. Mating Profiles. Materials. Mechanical. 3 Row 6.
Datamate Specification Materials Mechanical Mouldings: Glass-filled thermoplastic UL94V-0 Female contacts: rass shell, with eryllium opper inner contact Male contacts: Phosphor bronze Finish: See individual
More informationProportional Throttle Cartridges, Size 16
Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact
More informationMeta-MEC Manual Motor Starters
Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC
More informationEPP4 Pressure Regulator Basic G 1/4"
EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard
More informationDual Solenoid Gas Valve Installation
Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions
More informationPegasus Series Amphenol Pcd
Pegasus Series Amphenol Pcd Amphenol Pcd is one of the world s leading suppliers of interconnect products for Military, Commercial Aerospace and Industrial applications. Located north of Boston in Beverly,
More informationMass Flow Meter (MFM) for gases
Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationInstallation, operating and maintenance Instructions for Seemag bypass level indicator
Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates
More informationLimit switches OsiSense XC Special For material handling applications, type XC1 AC
Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics
More informationX2 Metallized Polypropylene Film Capacitor JFV
FEATURES: Non-inductive, (UL940V-0) plastic case sealed with epoxy resin. Provides interference suppression with VDE, ENEC and UL approvals. SPECIFICATIONS: Operating Temperature -40 ~ +110 Voltage Rating
More informationMUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.
Installation Instructions manual MUELLER table of contents PAGE A-20806 A-20807 Adjustable General Information 2 Technical Data 3 Dimensions 4 Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator
More informationPOWR-BLOKS Distribution/Splicer Blocks and Covers
SPECIFICATIONS Voltage : 600V erage: Based on NEC Table 310-16, using 75 C copper wire Material: Phenolic rated at 150 C and Thermoplastic rated at 125 C (LD1400 and LS1300 series only) : Standard: Highly
More informationTECHNICAL CHARACTERSTICS
and solenoid valves spool version GM - GL series Type of valves with dorsal consumption: GM-...series with integrated connections GL-...series without connections TECHNICAL CHARACTERSTICS Ambient temperature:
More information38999 Space grade ESA/SCC Section. MIL-DTL Space Grade Circular Connectors
38999 Space grade ESA/SCC 3401 Section II MI-DT 38999 Space Grade Circular Connectors 59 38999 Space Grade ESA/SCC 3401 Contents 38999 Space Grade ESA/SCC 3401 SCC Specification.......................................................61
More informationElectric expansion valves Types AKV 10, AKV 15 and AKV 20
Data sheet Electric expansion valves Types AKV 10, AKV 15 and AKV 20 AKV are electrically operated expansion valves designed for refrigerating plants. The AKV valves are normally controlled by a controller
More informationMUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.
Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read
More informationINSTRUCTION MANUAL Pressure Relief Device LPT
INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF
More informationOperating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
More informationpowr-bloks POWR-GARD Fuseblocks Distribution/Splicer Blocks and Covers Applications Connectors Description Ampere Ratings Specifications
powr-bloks Applications Typical applications include heating, air conditioning and refrigeration systems, el e va tor systems, material handling equipment, control panels, motor controls, switchgear, and
More information2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version
2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for
More informationInstallation, use and maintenance instructions. Gas burner (5)
Installation, use and maintenance instructions Gas burner MODEL GAS 4 TYPE 516 T80 291 (5) TECHNICAL FEATURES Thermal output 180-470 kw 154.800-404.200 kcal/h Fuel Natural gas Pci 8-10 kwh/m 3 = 7000-8600
More informationElectrical Sensing Edges
sensing the future Electrical Sensing Edges Electrical sensing edges for safeguarding machinery & robots, automatic doors & gates, and public transportation Reliable, proven, long lasting Wide variety
More informationCONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17
TABLE OF CONTENTS MAIDA S HISTORY TERMINOLOGY & GENERAL LEAD CODES and TAPE & REEL i ii iii STANDARD SERIES 1 HC SERIES 17 LOW PROFILE SERIES 33 THERMALLY PROTECTED SERIES 39 HIGH ENERGY SERIES LEAD CODES
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 9 5 14 40 35 11 9 5.4 M20 x 1.5 0102 S Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges
More informationSPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at:
SPOOL VLVS ISO 07/ - Sizes 0-0 Series 8-9 P68-GB-R ll leafl ets available at: www.ascojoucomatic.com FTURS These spool valves which comply with the VDM 6 standard offer the advantage of being smaller than
More informationUser Manual V14.1 IP68 LED FLEX NEON
User Manual V14.1 IP68 LED FLEX NEON PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE END USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE 1/11 PRODUCT SPECIFICATION 1. Operating
More informationEPIC Rectangular Connectors HBE Series
HBE Series The HBE series inserts are suitable for applications with high voltages and current. The inserts can be terminated in a variety of ways: screw, crimp, or spring cage clamp. TECHNICAL DATA Number
More informationRECTANGULAR CONNECTORS
RECTANULAR CONNECTORS CN-360 SERIES EATURES Many applications Various connectors are available for connection by means of soldering, wire wrapping, crimping, PC board mounting, and insulation displacement
More informationINSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008
INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008 0376/448/00 ISSUE 01 EMERGENCY PUSH PAD PULLMAN BOLT DEVICE TO EN 179 : 2008 1000mm MAXIMUM CLEAR OPENING HEIGHT WITH PUSH
More informationSPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection
SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges
More informationE3G-L1/L3. Effectively Cuts the Influence of Workpiece Characteristics, Such as Gloss, Incline, and Color. Distance-setting Photoelectric Sensor
Distance-setting Photoelectric EG-L/L CSM_EG-L_L_DS_E Effectively Cuts the Influence of Workpiece Characteristics, Such as Gloss, Incline, and Color. Be sure to read Safety Precautions on page. Features
More informationAvailable models Devices Color White sealing bellows Black sealing bellows NDT SW NDT GB NDT RT NDT GN NDT WS NDT BL NDT GR
Pushbuttons Left: type series N with sealing bellows, color white (standard). Right: type series N with sealing bellows, color black. Protective collar against unintentional actuation: refer to page 58
More informationIP65 Air Differential Pressure Switch
Page 1 of 5 PA-DPS-9x IP65 Air Differential Pressure Switch Features: Benefits: Close switching differential IP65 Housing Duct fixing kit included Switching point easily adjusted with scale in One screw
More informationPressure switches for air and water CS
Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the
More informationRPS900W Redundant Power Supply. Installation Guide.
RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A
More informationRG2 Gripper Datasheet Version 1.6
RG2 Gripper Datasheet Version 1.6 The RG2 gripper is a flexible electric gripper specially designed for robots from Universal Robots. The long stroke allows the gripper to handle a variety of object sizes.
More informationSolenoid valves VZWF, force pilot operated
Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is
More informationOPTIPOW 105 OPTIPOW 105 ; MAIN PARTS. Our Ref: PSE, Bernt Andersson
Page 1 (6) Our Ref: PSE, Bernt Andersson OPTIPOW 105 OPTIPOW 105, the compact pulse valve for the Optipulse fabric filters of different types: is a result of many years of experiences within the fabric
More informationDual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications
Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents
More informationE10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.
> Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to
More informationSERIES A24 RAISED RIB
SERIES A24 RAISED RIB Eurobelt Series A24 Raised Rib conveyor belt has been designed mainly to be used with finger plates. It has ribs that, sticking out 6 mm above the module, provide a greater resistance
More informationSpectrum AquaLight (SAL ) Color Underwater Light Owner s Manual
Spectrum AquaLight (SAL ) Color Underwater Light Owner s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents Section I. Installing Light Fixture
More informationMMCX Coaxial Connectors
The Amphenol MMCX series is the next generation of microminiature connectors. Offering a reliable broadband performance from DC to 6 GHz. These 50 ohm connectors incorporate the industryapproved MMCX interface,
More informationPneumatic spool valve islands
Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their
More informationParallel grippers HGPM, micro
Key features G6: G8: G9: stroke compensation clamping spigot flange mounting At a glance Compact, handy design With open or closed gripper jaws Versatility thanks to externally adaptable gripper fingers
More informationE8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)
Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless
More information