EU Declaration of Conformity
|
|
- Matthew Harris
- 5 years ago
- Views:
Transcription
1 Product: Name and address of the manufacturer: Rockwell Automation Inc. 101 South nd Street Milwaukee, WI 0 U.S.A. EU Declaration of onformity IE ircuit Breakers and Accessories Name and address of the authorised representative: Rockwell Automation B.V. Rivium Promenade LM apelle aan den Ijssel The Netherlands This declaration of conformity is issued under the sole responsibility of the manufacturer. Object of the declaration: Allen-Bradley 10M-R, 10M-, 10M-D, 10M- Series and Accessories (reference the attached list of catalogue numbers) The object of the declaration described above is in conformity with the relevant Union harmonisation legislation: 01//EU Low Voltage Directive (LVD) 01//EU ATEX Directive (ATEX) 011/6/EU RoHS Directive (RoHS) References to the relevant harmonised standards used or references to the other technical specifications in relation to which conformity is declared: EN 6097-:006+A1:009+ Low-voltage switchgear and controlgear Part : ircuit Breakers A:01 EN :010+A1:01 Low-voltage switchgear and controlgear Part -1: ontactors and motorstarters Electromechanical contactors and motor-starters EN :00+A1:009 Low-voltage switchgear and controlgear Part -1: ontrol circuit devices and switching elements Electromechanical control circuit devices EN 9-1:1996 Safety of machinery Safety-related parts of control systems Part 1: General principles for design EN :01 Explosive atmospheres Part 1: Electrical installations design, selection and erection EN 081:01 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Notified Body: Physikalisch Technische Bundesanstalt PTB (NB 010) performed: E Type Examination (ATEX) and issued the certificate(s): PTB 0 ATEX 09 Additional information: ATEX Markings: Ex II () G Signed for and on behalf of the above named manufacturer: Place and date of issue: Aarau, Switzerland 1-Jul-017 Name, function: Signature: Daniel Baumann, Manager Product ertification Engineering Document ontrol Number: P-0-J-EN (10M-T00B-EN-E) 1 / 7
2 atalogue number Series 1 Description 10M R 10M 10M D 10M IE ircuit Breakers, frame size 16A (with spring force terminals, for normal breaking capacity only) per Nomenclature IE ircuit Breakers, frame size A (with screw terminals, for normal breaking capacity) per Nomenclature IE ircuit Breakers, frame size A (with screw terminals, for high breaking capacity) per Nomenclature IE ircuit Breakers, frame size A (with screw terminals, for high breaking capacity only) per Nomenclature Directive ATEX LVD RoHS No Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes Accessories 10M Auxiliary ontact Blocks per Nomenclature Yes Yes Yes 10M Trip ontact Blocks per Nomenclature Yes Yes Yes 10M Left Side Mounting Trip unction per Nomenclature Yes Yes Yes 10M onnecting Modules per Nomenclature No N/R Yes 10M W ompact Busbars per Nomenclature No N/R Yes eeder Blocks per Nomenclature No Yes Yes eeder Terminals per Nomenclature No Yes Yes 10M WS Terminal overs per Nomenclature No N/R Yes 10M Knobs and Handles per Nomenclature No N/R Yes 10M SB Door coupling handles No N/R Yes 10M SY 10M TE1 10M TE Spacing Adapters No N/R Yes 10M N Screw Adapter No N/R Yes 10 KBH Top hat rail Adapter No N/R Yes 10M DS 10M DSL 10M S1 10M S Extension Shafts No N/R Yes 10M DN oupler No N/R Yes 10M SHS Shaft Support No N/R Yes 10M WD Jumper for 10M D to 10M No N/R Yes 10M PS 10M PS oil Module for 10M, 10M D to oil Module for 10M D, 10M to No N/R Yes 10M M Locking Tag No N/R Yes 10M A Anti-Tamper Shield No N/R Yes 1) If no series number is given, then all series are covered. ) No = Product is not certified to this directive. Yes = Product is certified to this directive. N/R = This directive is not required for this product. ) 10M E, 10M D8E certified up to A. See marking on product. Document ontrol Number: P-0-J-EN (10M-T00B-EN-E) / 7
3 MODEL NOMENLATURE: IE ircuit Breakers atalogue Number Explanation 10M 10M R 10M D M M 10M R 10M D 10M 8 E N T V A16 A A0 A6 B10 B16 B B0 B Optional -, followed by letters and digits Base atalogue Number IE ircuit Breaker rame Size A, with screw terminals, for normal breaking capacity IE ircuit Breaker rame Size 16A, with spring force terminals, for normal breaking capacity IE ircuit Breaker rame Size A, with screw terminals, for high breaking capacity IE ircuit Breaker rame Size A, with screw terminals, for high breaking capacity Breaking apacity Normal High ircuit Breaker with magnetic trip (1 1 times max. current) and thermal trip, for motor protection ircuit Breaker with magnetic trip (1 1 times max. current) only, for short circuit protection of motor starter combinations (with thermal overload relay) ircuit Breaker with high magnetic trip (16 1 times max. current) and thermal trip, for transformer protection ircuit Breaker suitable for VD applications, for frame size D only ode for urrent Range A, for frame sizes, D or R A, for frame sizes, D or R A, for frame sizes, D or R A, for frame sizes, D or R A, for frame sizes, D or R A, for frame sizes, D or R 1.6.A, for frame sizes, D or R..0A, for frame sizes, D or R.0 6.A, for frame sizes, D or R A, for frame sizes, D, or R 10 16A, for frame sizes, D, or R A, for frame sizes, D or 18 A, for frame sizes, D or 9A, for frame sizes, D only 7 A, for frame sizes, D only A, for frame size only A, for frame size only Options Such as additional Knobs, Auxiliary/Trip ontacts and / or Trip unctions Document ontrol Number: P-0-J-EN (10M-T00B-EN-E) / 7
4 A.) Auxiliary ontact Blocks Accessories atalogue Number Explanation 10M M Base atalogue Number of Auxiliary ontact Block Terminal Type No suffix letter R Screw Terminals Spring orce Terminals or ircuit Breaker Type AA ASA Two digits 10M, 10M D, 10M, 10U D Mounting Position ront mounted Right side mounted (with Screw Terminals only) ontact onfiguration of Auxiliary ontacts irst digit indicates number of N.O. contacts Second digit indicates number of N.. contacts B.) Trip ontact Blocks 10M M Base atalogue Number of Trip ontact Block Terminal Type No suffix letter R Screw Terminals Spring orce Terminals or ircuit Breaker Type 6 AA ASA No suffix Letter R, followed by two digits Letter A or M, followed by two digits 10M, 10M D, 10M, 10U D Mounting Position ront mounted Right Side mounted (with Screw Terminals only) ontact onfiguration of Auxiliary ontacts No Auxiliary contact is provided irst digit indicates number of N.O. contacts Second digit indicates number of N.. contacts ontact onfiguration of Auxiliary ontacts irst digit indicates number of N.O. contacts Second digit indicates number of N.. contacts Document ontrol Number: P-0-J-EN (10M-T00B-EN-E) / 7
5 Accessories atalogue Number Explanation (continued).) Left Side Mounting Trip unction 10M M Base atalogue Number of Left Side Mounting Trip unction Terminal Type No suffix letter Screw Terminals or ircuit Breaker Type 10M, 10M D, 10M, 10U D Trip unction U UX SN Undervoltage Undervoltage Shunt ontrol Voltage ode (indicates voltage and frequency) One or two letters A voltage code (in the range of 1 V0Hz or 1 600V60Hz) D voltage code (in the range of 9 0VD). Two letter code starting with Z. D.) onnecting Modules 10M M Base atalogue Number of onnecting Module or ircuit Breaker Type D 10M 10M D 10M PE PN P onnecting Module Type EO Standard lexible Interconnection to ontactor Type 100 K 100 K 1 Indicates max. current 1A, for interconnection of 10M to 100 K Indicates max. current A, for interconnection of 10M or 10M D to with A coils or VD electronic coil A Indicates max. current A, for interconnection of 10M or 10M D to with conventional D coil DM lexible Module only. Indicates max. current A/A, for interconnection of 10M or 10M D to with A or D coil 7 Indicates max. current 7A, for interconnection of 10M D or 10M to , with A coil Indicates max. current A, for interconnection of 10M to 100 with A coil Document ontrol Number: P-0-J-EN (10M-T00B-EN-E) / 7
6 Accessories atalogue Number Explanation (continued) E.) ompact Busbars, eeder Blocks and eeder Terminals 10M - - W M Base atalogue Number of ompact Busbar, eeder Block or eeder Terminal or ircuit Breaker Type 10M, 10M D (not for eeder Block) 10M W Indicates ompact Busbar, eeder Block or eeder Terminal Three-Phase ompact Busbar Two digits, followed by another digit The first two digits indicate the spacing in mm Last digit indicates the number of connections Two letters, starting with ompact Busbar eeder Block B Two or three letters, starting with T ompact Busbar eeder Terminal No suffix N rame size of ircuit Breaker A A.) Terminal overs 10M - - WS M Base atalogue Number of Terminal over or ircuit Breaker Type 10M, 10M D 10M WS Indicates over Type rame size of ircuit Breaker No suffix N A A Document ontrol Number: P-0-J-EN (10M-T00B-EN-E) 6 / 7
7 G.) Knobs and Handles Accessories atalogue Number Explanation (continued) 10M M Base atalogue Number of Knobs and Handles or ircuit Breaker Type 10M, 10M D, 10M, 10U D 10M KN, KN1 Lockable Twist Knob (black) KRY, KRY1 Lockable Twist Knob (red/yellow) DN66 Door oupling Handle (black) DRY66 Door oupling Handle (red/yellow) Document ontrol Number: P-0-J-EN (10M-T00B-EN-E) 7 / 7
EU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation Inc. 1201 South 2nd Street Milwaukee, WI 53204 U.S.A. EU Declaration of Conformity Global Moulded Case Circuit Breaker Accessories Name
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation Inc. 1201 South 2nd Street Milwaukee, WI 53204 U.S.A. EU Declaration of Conformity Global Moulded Case Circuit Breaker Accessories Name
More informationMeta-MEC Manual Motor Starters
www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more
More informationReferences 6 k thermal overload relays, adjustable from 0.11 to 16 A
s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure
More informationLondon Underground - Section 12 approved Switch Disconnectors
Introduction Following the Kings Cross fire of 1987, the resulting Fennell enquiry prompted the introduction of additional fire precautions for Sub-surface Railway Stations. These additional requirements
More informationMiniature controls. Contactors. Overload relays. Starters. Control relays
Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power
More informationEx-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC
www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive
More informationDK46 - DK800 Supplementary instructions
DK46 - DK800 Supplementary instructions Variable area flowmeter Device category II2G with electrical internals Additional Ex manual KROHNE CONTENTS DK46 - DK800 1 Safety instructions 3 1.1 General... 3
More informationSeries CL. Contactors. Intro J/X. Three and four pole contactors 9 to 105A (AC3) 25 to 140A (AC1) Standard voltages. Standards. Approvals A.52.
Three and four pole contactors 9 to 105 (3) 25 to 140 (1) ontrol circuit: lternating up to 690V irect up to 440V Terminal numbering in accordance with N 50005 and N 50012 ixing by clipping onto 35mm N
More informationCurrent transformers. Measurement devices. 2 General Catalogue SOCOMEC. Measurement devices NEW. ÂÂEnergy efficiency
NEW trafo_108_a_1_cat Three-phase CT trafo_010_a_1_cat trafo_077_b_1_cat trafo_012_a_1_cat ÂÂEnergy efficiency 0.2s We offer class 0.2s for your energy efficiency or MD applications. appli_294_a ÂÂFunction
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION Exhaust Hose Reel ser. 865, electric motor driven No. 981118101 Description Limit switches, for hose coiling and uncoiling integrated in drive unit. Motor turns drum via a planetary
More informationMeta-MEC Manual Motor Starters
Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC
More informationManual Power relay SR853
Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection
More informationKAL36150 Molded Case Circuit Breaker, 600VAC, 150A
Product ata Sheet KL3 Molded ase ircuit reaker, 00V, List $1,733.00 US vailability Stock Item: This item is normally stocked in our distribution facility. Technical haracteristics pprovals UL Listed -
More informationCircuit breakers PR 60
Circuit breakers PR series are mechanical switching devices able to switch, conduct and switch-off the current under normal conditions and able to switch, conduct and automatically switch-off the current
More informationTeSys protection components
Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively
More informationS(U)200 series SU200M, SU200MR, and S200UDC UL 489 series
S(U)00 series SU00M, SU00MR, and S00UDC UL 489 series Description The SU00M, SU00MR, and S00UDC miniature circuit breakers offer a compact solution for protection requirements. The SU00 series devices
More informationUCA-UVO-UCB. SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 pole - 50 Hz OPERATING LIMITS APPLICATIONS CHARACTERISTICS ADVANTAGES
OPERATING LIMITS Flow rates up to: 24 m 3 /h Head up to: 62 m Maximum immersion depth: 12.5 m Max. particle size: Ø 5 to 8* ND discharge port: 8/1 mm IP : 68 *depending on model SUBMERSIBLE PUMPS Lifting
More information5 Loads and Motor Switchgears
5 Loads and Motor Switchgears Standard Motor Starters BQD Series Explosion-proof Motor Starters to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone Class I, Zone 1 and Zone 2 Class
More informationLiquid level switch BM 34
KROHNE 09/2001 7.02370.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level
More informationtrafo_011_a_1_cat Bar or cable-through Multiple applications per: - cables: Ø 17 to Ø 100 mm, - bars: 20 x 5 mm to 2 x 125 x 10 mm.
Current transformers Measurement devices trafo_012_a_1_cat trafo_077_b_1_cat trafo_010_a_1_cat trafo_008_a_1_cat trafo_011_a_1_cat Functions SOCOMEC current transformers deliver to the secondary a standard
More informationRMG Meßtechnik GmbH. Publication No E
Electronic Turbine Meter TERZ 94 RMG Meßtechnik GmbH Publication No. 3.174-E P.O.ox 280 35502 utzbach (Germany) Tel.: +49 (0)6033 897-0 Fax: +49 (0)6033 897-130 E-mail: messtechnik@rmg.de Internet: http://www.rmg.de
More informationCurrent transformers Measurement devices from 5 to 5000 A
Metering, monitoring & power quality trafo_108_a_1_cat Current transformers Three-phase CT trafo_012_a_1_cat The solution for > ndustry. > Service sector. Strong points trafo_077_b_1_cat trafo_010_a_1_cat
More informationProject: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15
PRCEDURES FR RUTINE TESTING F CAPACITR BANKS Consultant : MEP Contractor: Project: PREPARED BY: DRMAN SMITH SWITCHGEAR - DUBAI NAME: REVIEWED BY CNSULTANT : NAME: SIGNATURE: SIGNATURE: Page 1 of 15 Table
More informationRetrofitting kit New Emax Direct Replacement of Megamax and Novomax
New Emax Direct of Megamax and Novomax With just very few modifications and sustainable costs, Retrofitting kits are the perfect solution for improving low voltage switchgear. The direct replacement retrofitting
More informationRP series Rotor Pumps
ontact etails RP series Rotor Pumps Nomenclature Features Low noise Substantial reduction of the operation noise, by to db (comparison with aikin products), and improved sound quality are achieved by adopting
More informationPressure Measurement Single-range transmitters for general applications
Siemens A 207 Overview Application The SITRANS P Compact pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials
More informationMaxSB - Low Voltage Switchboard
BU 3101 Low Voltage Systems, March 2009 Low Voltage Systems MaxSB - Low Voltage Switchboard May 5, 2009 Slide 1 MaxSB Product Overview Description Value Rated Main bus current 1600A, 2000A, 3000A, 3200A,
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationElectronic Turbine Meter TERZ 94
Electronic Turbine Meter TERZ 9 PRODUT INFORMTION Reliable Measurements of Gas EETRONI TURINE METER TERZ 9 Methode of operation, construction 2 Methode of operation The TERZ 9 electronic turbine meter
More informationControl and Automation
GE Consumer & Industrial Power Protection Control and Automation Electronic relays GE imagination at work Electronic relays Order codes F.3 Series DM Single voltage electronic timers. 22.5mm module F.4
More informationOperating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
More informationOperating Instructions
Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2
More informationPressure switch KP-E. Data sheet
Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches
More informationProcess Solutions. Electronic Turbine Meter TERZ 94 PROVEN TECHNOLOGY. SUPERIOR PERFORMANCE.
Process Solutions Electronic Turbine Meter TERZ 9 PROVEN TEHNOOGY. SUPERIOR PERFORMNE. Electronic Turbine Meter TERZ 9 Method of Operation The TERZ 9 electronic turbine meter is a flow meter which directly
More informationRosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch
Technical Note ommunicate Rosemount 2130 Rosemount 2130 Extreme Temperature Vibrating Fork Liquid Level Switch The Rosemount 2130 Vibrating Fork Level Switch, based on vibrating short fork technology,
More informationActuating elements for ComEx
Description A large number of variants and versions of actuating elements are available for the ComEx control and indicator units. All actuating elements are made of high-quality thermoplastic and conform
More informationPRICE LIST Effective From January LV SWITCHGEAR. Be Switch. The Real Switchgear 230 V. SwitchTM INDUSTRIAL PIONEER VALUE CREATOR
PRICE LIST Effective From January - 0 LV SWITCHGEAR SwitchTM Be 0 V INDUSTRIAL PIONEER VALUE CREATOR TM BeC BeC BeC Be S w i t c h BeC - BeC AC POLE POWER CONTACTOR 0 AC Duty Ampere BeC - 00 / 00 AMP.
More informationenclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)
enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) Stainless steel and plastic enclosures for use in potentially explosive environments R Rittal system partners Perfect
More informationPSSI 1 High Voltage Switching
1. SCOPE This Safety Instruction sets down the procedures to be adopted when carrying out High Voltage (HV) Switching operations on The Company s System and other System(s) operated by the Company other
More informationPressure switch with bourdon tube
Pressure switch with bourdon tube for plants requiring special supervision,type series BN4 Features Pressure switch with bourdon tube for plants requiring special supervision, Nominal ranges -1...0 bar
More informationOperating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073
Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4
More informationBourdon tube pressure gauge for diaphragm seals
Bourdon tube pressure gauge for diaphragm seals and switch function, Type series BR42.. Features Bourdon tube pressure gauge for diaphragm seal and switch function Nominal range -1 3 bar to -1 15 bar,
More informationA17W49_MASEM_F_EN MANUAL
AW9_MASEM_F_EN MANUAL CONTENTS Identification. Manufacturer. Product name. Year of manufacture. Area of use. Declaration of conformity Technical specification. Design. Function. Technical data. Electrical
More informationPressure control, differental pressure control and thermostat Type RT
MAKING MODERN LIVING POSSIBLE Technical brochure Pressure control, differental pressure control and thermostat Type RT Hydrocarbons www.danfoss.com/hydrocarbons Contents Page Introduction...3 Approvals...3
More informationGas density monitor With integrated transmitter Model GDM-100-TI
SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed
More informationComEx Actuating elements
ComEx Actuating elements for Zone and 2 ComEx Actuating elements Features Easy installation Certified for Zone and 2 High IP degree of protection A large number of variants and versions of actuating elements
More informationTheatre Control Panel. Instructions for Use. January 2017 ASF-29 (1)
Theatre Control Panel Instructions for Use January 2017 0197 ASF-29 (1) Contents 1. Instructions For Use 1.1. Introduction 1.2. Explanation of Symbols 1.3. General Safety Instructions Intended Use Operating
More information3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.
3G Operating instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 01. July 2011/Rev. 0 Operating Instructions Type: 03-5110-00.. Document no.: 03-5110-7D0001 Version: 1 July 2011 / Rev.
More informationGA24 Technical Datasheet
GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features
More information7Flat-Trak Model 780S. Smart In-Line Thermal Gas Mass Flow Meter with Flow Conditioner. For information online...
Smart In-Line Thermal Gas Mass Flow Meter with Flow onditioner Features Direct mass flow monitoring eliminates need for seperate temperature and pressure inputs Built-in flow conditioner which eliminates
More informationOrifice Plate Flow Meter
Orifice Plate Flow Meter FOFT Measuring Principle The principle of measuring the differential pressure is based on the fact that a differential pressure is created across that section of a pipe where its
More informationProtection of motor circuits
Protection of motor circuits Circuit breaker/contactor coordination A circuit supplying a motor may include one, two, three or four switchgear or When a number of devices are used, they must be coordinated
More information1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type
Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing
More informationLTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.
LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42
More informationProportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20
More informationPressure controls for hydro carbons, zone II applications, Type KPE
MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls for hydro carbons, zone II applications, Type KPE KPE pressure controls for use in refrigeration and air conditioning systems with hydrocarbons
More informationInstallation and Operating Instructions Bypass Flow Meter DST
Installation and Operating Instructions Bypass Flow Meter DST DST_gb_A4_1.0.doc Version 1.0 1 von 10 Contents 1. Foreword... 3 2. Safety... 3 2.1. Symbol and meaning... 3 2.2. General safety directions
More informationExercise 3-2. Two-Wire and Three-Wire Controls EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Two-wire control
Exercise 3-2 Two-Wire and Three-Wire Controls EXERCISE OBJECTIVE Construct two-wire and three-wire control circuits and understand their principles. DISCUSSION OUTLINE The Discussion of this exercise covers
More informationTechnical Data. Dimensions
0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type
More informationXML Electromechanical Pressure Switches
Selection Guide Industrial Switches Type of installation ontrol circuits Applications Media controlled Type of operation Air, water, hydraulic oils, corrosive fluids, viscous products Fixed differential:
More informationFunctional Example CD-FE-I-029-V30-EN Safety-related controls SIRIUS Safety Integrated
Functional Example Safety-related controls SIRIUS Safety Integrated Two safety circuits in a cascade up to SIL 3 acc. to IEC 6206 and PL e acc. to ISO 3849- with ET 200S Safety Motorstarter Solution Local
More informationFMAC Sine FMAC Sine DCL
emc Sine Output Filter www.schurter.com/pg8 FMAC Sine FMAC Sine DCL -Phase Filters Sine wave output filter Description - Design corresponding to UL 128, CSA 22.2 No. 8, IEC/EN699 - Standard versions include
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic
More informationINVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:
direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting
More informationIEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)
IEC 62271-200 April 2004 Authorized Sole Agent : PT. Wisma Niagatama Perkasa Phone : (031) 5041242 Fax. : (031) 5044580 IEC 62271-200 Introduction Scope This standard specifies requirements for factory-assembled
More informationSolenoid valves VZWF, force pilot operated
Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is
More informationElectropneumatic Positioner and Pneumatic Positioner Type 3760 JIS
Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or
More information(Certification N:o VTT 08 ATEX 066 or IECEx VTT )
(Certification N:o VTT 08 ATEX 066 or IECEx VTT 12.0009) Thank you for choosing Slam Hornet portable work light for your job site. Purpose of this manual is to provide you all the necessary safety and
More informationenclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)
lri030784900.eps lri031083400.eps enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) fri040466500.eps Stainless steel and plastic enclosures for use in potentially explosive
More informationMultiple Connection Manifolds
ultiple onnection anifolds PNUAYN, IN. atalog 2400 Phone 763-559-0177 ax 763-559-0547 eatures l 2 to 10 stations l Inline anifolds, 90 anifolds, ual Air, unction locks and Terminal locks l ustom designs
More informationBrooks TMF-Zone 1 Models 5816-Ex/5864-Ex
Data Sheet DS-TMF-586Ex-MFC-eng TMF-Zone Brooks TMF-Zone Models 586-Ex/5864-Ex Customer Benefits Assured process accuracy and repeatability Long-term reliability Reduced maintenance CE certified Improved
More informationMARIPOSA COUNTY LOCKOUT/TAGOUT PROGRAM
MARIPOSA COUNTY LOCKOUT/TAGOUT PROGRAM INTRODUCTION Mariposa County ( County ) facilities have equipment and systems that must be deenergized to allow for safe cleaning, repairing, servicing, setting-up,
More information2/2-way proportional valve
2/2-way proportional valve High sensitivity Type can be combined with 0... 16 bar DN 0.8... 4 mm 1/8, 1/4 or sub-base EEx approvals optional Type 8605 Digital control electronics Cable plug version Type
More information2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version
2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for
More informationV83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability
V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability > > Modular design - Maxseal valves > > able terminations inside coil housing
More informationPressure Switches Application Guideline
Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment
More informationVK8515M(R) MODULATING GAS CONTROL APPLICATION DESCRIPTION SPECIFICATIONS INSTRUCTION SHEET. Electrical data
VK8M(R) MODULATING GAS CONTROL INSTRUCTION SHEET Main gas connection Connections with G / external thread fitted with nuts according to ISO 8- in combination with applicable sealing(s) withstand the torsion
More informationATH-EXx. B Operating Instructions
ATH-EXx Explosion-protected surface-mounted thermostat for potentially explosive gas atmosphere Zone 1 and potentially explosive dust atmosphere Zone 21 B 605051.0 Operating Instructions 2011-04-01/00379556
More informationCALEFFI. Ball zone valves. series /03 GB
all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the
More informationControl units. Installation and operating instructions Series: DP-Control
Control units Installation and operating instructions Series: DP-Control Table of Contents 1 Manual introduction 1.1 Preface... 4 1.2 Icons and symbols... 4 2 Identification, service and technical support
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationII 2G EEx ia IIC T6. Ignition protection class
ATEX General information According to 94/9/EC, a device that is to be used in an environment at risk of explosion may only be brought into the market if it satisfies the standards specified in the norm.
More informationPressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"
I. MISCELLANEOUS Guideline I-01 Guideline related to: Article 4 paragraph 3 What is to be understood by "sound engineering practice"? Sound engineering practice means, without prejudice to Article 5, paragraph
More informationMHS BY(D)
003-010() Parts List This parts list is current as of the above revision date. To find your aikin Applied parts distributor, call 1-800-377-2787 or visit www.aikinapplied.com Form Number: 92-42807-003-010()
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:
More informationVMR VMR-OTN VMR 6 bar
VMR VMR-OTN VMR 6 bar Safety solenoid valves for gas Fast opening and fast closing type DN8 DN150 delta-elektrogas.com EE161-03/17 VMR VMR-OTN VMR 6 bar Safety solenoid valves for gas Fast opening and
More information2-port and 3-port valves PN 16
OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port
More informationPressure switch, Differential pressure switch and Thermostat RT-E
Data sheet Pressure switch, Differential pressure switch and Thermostat RT-E The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 9 5 40 35 14 11 9 5.4 M20 x 1.5 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting Satisfies machinery
More informationQPL... Pressure Switches. Siemens Building Technologies HVAC Products
7 221 Pressure Switches QPL... The pressure switches are used for monitoring gas or air pressures. When the pressure falls below the switching point, the associated electrical circuit will open or switch
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More informationSolenoid valve type EVR for Hydrocarbons
MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valve type EVR for Hydrocarbons EVR for Hydrocarbons is a direct or servo operated solenoid valve especially designed for liquid, suction, and
More informationEC design-examination certificate
beglaubigte Übersetzung aus dem Deutschen ins Englische Certified Translation from German into English [Coat of Arms] EC design-examination certificate Issued to: In accordance with: Type of instrument:
More informationEP500 Advanced ATEX Electropneumatic Positioner
3.568.5275.306 IM-P343-46 CH Issue 2 EP500 Advanced ATEX Electropneumatic Positioner Installation and Maintenance Instructions 1. Safety information 2. Technical Information 3. Installation 4. Commissioning
More informationInspection and Testing
Chapter 16 Inspection and Testing 16.1 INTRODUCTION The Purpose of Inspection, Testing and Certification or Reporting The fundamental reason for inspecting and testing an electrical installation is to
More informationDSL, DSH: Specially designed pressure limiter
Product data sheet 11.1 23.770 DSL, DSH: Specially designed pressure limiter How energy efficiency is improved Control and monitoring according to needs and with no auxiliary energy. Features Switching
More informationCMC Series Moulded Case Circuit Breaker Cielo Electric
Model name CMC: Series 225: mpere frame size Line side terminal In: Rated current Ue: Rated operational voltage Icu: Rated ultimate short-circuit breaking capacity Ta: mbient temperature In: 225 Icu: 55k@415V
More informationATH-EXx. B Operating Instructions
ATH-EXx Explosion-protected surface-mounted thermostat for potentially explosive gas atmosphere Zone 1 and potentially explosive dust atmosphere Zone 21 B 60.5051.0 Operating Instructions 05.08/00379556
More information