5 Loads and Motor Switchgears
|
|
- Vivian Cobb
- 6 years ago
- Views:
Transcription
1 5 Loads and Motor Switchgears Standard Motor Starters BQD Series Explosion-proof Motor Starters to -CENELEC -IEC -NEC Can be used in Zone 1 and Zone 2 Zone 21 and Zone Class I, Zone 1 and Zone 2 Class I, Division 1, Groups C, D Class I, Division 2, Groups A, B, C, D Classified as IIB or IIC according to different gas atmospheres. Different motor starters. Copper-free aluminium enclosure; powder urface. Catalogue number logic BQD - / / / S: direct-on-line control (optional) N: reversible control Y: star-delta control Setting current of Explosion-proof motor starters Note 1. Please select the model by catalogue number logic above, and specify all technical data; 2. Please specify explosion-proof mark when ordering; 3. Entry size, entry direction, enclosure material, etc. on request. Zones 1&2; 21& 5/10
2 Standard Motor Starters BQD Series Explosion-proof Motor Starters (Ex d IIB) 5 Explosion-proof motor starters (direct-on-line control) BQD- / / Gas explosion protection Dust explosion protection For gas explosion protection For dust explosion protection material colour gland (optional) II 2 G Ex d IIB T6 Ex td A21 T80 LCIE 06 ATEX 6090; IECEx LCI PCEC (China) EN :2004, EN :2004 IEC :2004, IEC :2003, IEC :2004, IEC :2004 Window grey (RAL70) MCB (mini circuit breaker) Indicator, pushbutton 380/0V AC /60Hz DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20~ of contactor (A) BQD-4/16/7~ ~10, Ie= x M x BQD-5.5/20/9~ ~13, Ie= x M x BQD-7.5//12~ ~18, Ie= BQD-11//16~ ~24, Ie=23 BQD-15//23~ 15 23~, Ie=30 BQD-//30~38 30~38, Ie=36 2 x M x 1.5 BQD-//37~ 37~, Ie=46 2 x M x 1.5 4kW-7.5kW 11kW-kW 5/11
3 5 Standard Motor Starters BQD Series Explosion-proof Motor Starters (Ex d IIB) Explosion-proof motor starters (reversible control) BQD- / / /N Gas explosion protection Dust explosion protection For gas explosion protection For dust explosion protection material colour gland(optional) II 2 G Ex d IIB T6 Ex td A21 T80 LCIE 06 ATEX 6090; IECEx LCI PCEC (China) EN :2004, EN :2004 IEC :2004, IEC :2003, IEC :2004, IEC :2004 Window grey (RAL70) MCB (mini circuit breaker) Indicator, pushbutton 380/0V AC /60Hz DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20~ of contactor (A) BQD-4/16/7~10/N ~10, Ie= x M x BQD-5.5/20/9~13/N ~13, Ie= x M x BQD-7.5//12~18/N ~18, Ie= BQD-11//16~24/N 11 16~24, Ie= BQD-15//23~/N 15 23~, Ie= BQD-//30~38/N 30~38, Ie=36 2 x M x BQD-//37~/N 37~, Ie=46 2 x M x kW-7.5kW 11kW-kW 5/12
4 Standard Motor Starters BQD Series Explosion-proof Motor Starters (Ex d IIB) 5 Explosion-proof motor starters (star-delta control) BQD- / / / Y Gas explosion protection Dust explosion protection For gas explosion protection For dust explosion protection material colour gland (optional) II 2 G Ex d IIB T6 Ex td A21 T80 LCIE 06 ATEX 6090; IECEx LCI PCEC (China) EN :2004, EN :2004 IEC :2004, IEC :2003, IEC :2004, IEC :2004 Window grey (RAL70) MCB (mini circuit breaker) or MCCB (moulded case circuit breaker) Indicatior, pushbutton 380/0V AC /60Hz DQM-II (Ex d) or DQM-III (Ex d) is recommended. Please see P7/20~ Setting value of delay time BQD-//30-/Y 30~, Ie=36 13s 3 x M x BQD-//37-/Y 37~, Ie=46 15s 3 x M x BQD-30/80/48-65/Y ~65, Ie=60 17s 3 x M x BQD-37/100/-80/Y ~80, Ie=75 18s 3 x M x BQD-45/1/80-104Y ~104, Ie=90 20s 3 x M x kw-kw 30kW-45kW 5/13
5 5 Standard Motor Starters BQD Series Explosion-proof Motor Starters (Ex de IIC) Explosion-proof motor starters (direct-on-line control) BQD- / / material colour gland (optional) II 2 G Ex de IIC T6 Ex de IIC T6 Gb LCIE 10 ATEX 3075; IECEx CQM X EN :2006, EN :2004, EN :2007 IEC :2007, IEC :2007, IEC :2006 Window grey (RAL70) MCB (mini circuit breaker) Indicator, pushbutton 380/0V AC /60Hz DQM-I (Ex e) is recommended. Please see P7/17~19 of contactor (A) BQD-4/16/7~ ~10, Ie= x M x 1.5 BQD-5.5/20/9~ ~13, Ie= x M x 1.5 BQD-7.5//12~ ~18, Ie=16 18 BQD-11//16~ ~24, Ie=23 BQD-15//23~ 15 23~, Ie=30 BQD-//30~38 30~38, Ie=36 2 x M x 1.5 BQD-//37~ 37~, Ie=46 2 x M x 1.5 4kW-kW 5/14
6 Standard Motor Starters BQD Series Explosion-proof Motor Starters (Ex de IIC) 5 Explosion-proof motor starters (reversible control) BQD- / / /N material colour gland(optional) II 2 G Ex de IIC T6 Ex de IIC T6 Gb LCIE 10 ATEX 3075; IECEx CQM X EN :2006, EN :2004, EN :2007 IEC :2007, IEC :2007, IEC :2006 Window grey (RAL70) MCB (mini circuit breaker) Indicator, pushbutton 380/0V AC /60Hz DQM-I (Ex e) is recommended. Please see P7/17~19 of contactor (A) BQD-4/16/7~10/N ~10, Ie= x M x 1.5 BQD-5.5/20/9~13/N ~13, Ie= x M x 1.5 BQD-7.5//12~18/N ~18, Ie=16 18 BQD-11//16~24/N 11 16~24, Ie=23 BQD-15//23~/N 15 23~, Ie=30 BQD-//30~38/N 30~38, Ie=36 2 x M x 1.5 BQD-//37~/N 37~, Ie=46 2 x M x 1.5 4kW-kW 5/15
7 5 Standard Motor Starters BQD Series Explosion-proof Motor Starters Incoming line Code of electric components QF: circuit breaker KM: FR: thermal relay FU1, FU2: fuse SB1: stop button SB2: start button HR: power indicator Load line HG: running indicator Direct-on-line motor starter Incoming line Code of electric components QF: circuit breaker KM1, KM2: FR: thermal relay FU1, FU2: fuse SBS: stop button SB1: non-reversible start button SB2: reversible start button HR: power indicator Load line HG1: non-reversible running indicator HG2: reversible running indicator Reversibly controlled motor starter 5/16
8 Standard Motor Starters BQD Series Explosion-proof Motor Starters 5 Incoming line Code of electric components QF: circuit breaker KM1: main contactor KM3: star start contactor KM2: triangle running contactor FR: thermal relay FU1, FU2: fuse SB1: stop button Load line SB2: start button HR: power indicator HY: star start indicator HG: triangle running indicator Star-delta controlled motor starter 5/17
Junction Boxes Series 8118
> Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:
More informationOperating Instructions
Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2
More informationenclosed product catalogue 2010 isolating switches main/emergency off switches changeover switches insulated stainless steel mild steel
enclosed product catalogue 2010 isolating switches main/emergency off switches changeover switches insulated stainless steel mild steel kraus & Naimer enclosed switch catalogue Contents This catalogue
More informationOperating Instructions
Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table
More informationOperating Instructions
LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.
More informationReferences 6 k thermal overload relays, adjustable from 0.11 to 16 A
s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure
More informationE10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.
> Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to
More informationProtection of motor circuits
Protection of motor circuits Circuit breaker/contactor coordination A circuit supplying a motor may include one, two, three or four switchgear or When a number of devices are used, they must be coordinated
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 10 mm
Dimensions M30x1,5 5 40 37 0102 Model Number 36 LED Features Comfort series 10 mm embeddable Connection BN BU Accessories BF 30 Mounting flange, 30 mm L+ L- Technical Data specifications Switching element
More informationATMI Applications Techniques Modernes Industrielles
ATMI Applications Techniques Modernes Industrielles Z.A. de l observatoire - 2, avenue des Bosquets - 78180 Montigny-le-bretonneux - France Phone: +33 (0)1 61 37 35 60 - Fax: +33 (0)1 61 37 35 69 - info@atmi.fr
More informationFurther technical information is available on
1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,
More informationPRICE LIST Effective From January LV SWITCHGEAR. Be Switch. The Real Switchgear 230 V. SwitchTM INDUSTRIAL PIONEER VALUE CREATOR
PRICE LIST Effective From January - 0 LV SWITCHGEAR SwitchTM Be 0 V INDUSTRIAL PIONEER VALUE CREATOR TM BeC BeC BeC Be S w i t c h BeC - BeC AC POLE POWER CONTACTOR 0 AC Duty Ampere BeC - 00 / 00 AMP.
More informationActuating elements for ComEx
Description A large number of variants and versions of actuating elements are available for the ComEx control and indicator units. All actuating elements are made of high-quality thermoplastic and conform
More informationManual Power relay SR853
Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection
More informationIECEx certification of Non-Electrical Ex Equipment
IECEx certification of Non-Electrical Ex Equipment Thierry Houeix Ex Certification Officer Brief history of Non Electrical Ex Equipment standards In 2008, during the SC31M Plenary meeting it was decided
More informationReg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS
Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST
More informationTeSys protection components
Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively
More informationTechnical Data. Dimensions
0102 Model Number Features 10 mm flush Shielded PUR cable for oil and gas sector Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching function Normally closed (NC) Output type
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 1.5 mm
0102 Model Number Features 1.5 mm flush Accessories BF 8 Mounting flange, 8 mm Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 1.5 mm Installation flush
More information1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS
1.8 INDUSTRIAL PROCESS WEIGHING IN HAZARDOUS AREAS EXPLOSION PROTECTION In addition to the type approval and certification of industrial weighing systems concerned with accuracy, equipment that is also
More information4/2 way Pneumatic Solenoid Valve
4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11
More informationTechnical Data. General specifications. Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Technical Data specifications Switching function Normally closed (NC) Output type NAMUR Rated operating distance s n 2 mm Installation
More informationDimensions. Technical Data General specifications Switching element function Rated operating distance s n 5 mm
Dimensions M18x1 37 40 4 0102 24 LED Model Number Features 5 mm embeddable Usable up to SIL2 acc. to IEC 61508 Connection BN BU Accessories L+ L- EXG-18 Quick mounting bracket with dead stop BF 18 Mounting
More informationEX-RECESSED CEILING LIGHT FITTINGS
EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic
More informationTechnical Data. Dimensions
0102 Model Number Features 2 mm flush Usable up to SIL2 acc. to IEC 61508 Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 2 mm Installation flush Output
More informationCMC Series Moulded Case Circuit Breaker Cielo Electric
Model name CMC: Series 225: mpere frame size Line side terminal In: Rated current Ue: Rated operational voltage Icu: Rated ultimate short-circuit breaking capacity Ta: mbient temperature In: 225 Icu: 55k@415V
More informationTechnical Data. Dimensions
00 Model Number Features Comfort series 30 mm non-flush Accessories MHW 0 Modular mounting bracket V-G Female connector, M, 4-pin, field attachable V-W-N-M-PUR Female cordset, M, -pin, NAMUR, PUR cable
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable
More informationComEx Actuating elements
ComEx Actuating elements for Zone and 2 ComEx Actuating elements Features Easy installation Certified for Zone and 2 High IP degree of protection A large number of variants and versions of actuating elements
More informationMeta-MEC Manual Motor Starters
www.lsis.biz Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LS Meta-MEC Manual Motor Starters deliver more
More informationHazardous (Classified) Locations
Hazardous (Classified) Locations Presented by: John Chambers UL HazLoc operations Presented at: Safety & You in 2002 2002 Safety Conference Flexible Packaging Association (FPA) 1 AREA CLASSIFICATIONS Class
More informationLighting Contactors. 4.1 UL Rated AC Contactors
Electrically Held Lighting Contactors.1 Product Description....................................... Application Description.................................... Standards and Certifications................................
More informationII 2G EEx ia IIC T6. Ignition protection class
ATEX General information According to 94/9/EC, a device that is to be used in an environment at risk of explosion may only be brought into the market if it satisfies the standards specified in the norm.
More informationDimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm
Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection
More informationEU Declaration of Conformity
Product: Name and address of the manufacturer: Rockwell Automation Inc. 101 South nd Street Milwaukee, WI 0 U.S.A. EU Declaration of onformity IE ircuit Breakers and Accessories Name and address of the
More informationImplementation of Electrical and Instrument Installation in Hazardous Area Classification
Implementation of Electrical and Instrument Installation in Hazardous Area Classification Rosihan Anwar - Pertamina Hulu Energi ONWJ Phe.pertamina.com IECEx Conference, Jakarta 8-9 August 2018 PERTAMINA,
More informationA Unified Marking System for Ex Equipment
CERTEX Appointed Ex Laboratory Reg No: 1999/027771/07 (Pty) Ltd Government Approved Inspection Authority T0104 PO Box 467 Tel: +27 (11) 316 4601 Olifantsfontein Fax: +27 (11) 316 5670 1665 E- mail: info@explolabs.co.za
More informationABB MEASUREMENT & ANALYTICS DATA SHEET. AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators
ABB MEASUREMENT & ANALYTICS DATA SHEET AK100 Series ATEX compliant gas analyzer system for hydrogen-cooled alternators AK100 S E RIE S ATEX COMP LI AN T GAS ANALY ZE R SYSTE M DS/AK100-E N RE V. O Measurement
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating
More information(Certification N:o VTT 08 ATEX 066 or IECEx VTT )
(Certification N:o VTT 08 ATEX 066 or IECEx VTT 12.0009) Thank you for choosing Slam Hornet portable work light for your job site. Purpose of this manual is to provide you all the necessary safety and
More informationFunctional Example CD-FE-I-029-V30-EN Safety-related controls SIRIUS Safety Integrated
Functional Example Safety-related controls SIRIUS Safety Integrated Two safety circuits in a cascade up to SIL 3 acc. to IEC 6206 and PL e acc. to ISO 3849- with ET 200S Safety Motorstarter Solution Local
More informationPumping Stations. Double Control Unit for Two Pumps with or without Explosion Protection with Bubbler Control System (Dynamic) DDEL / DSEL
Operating Instructions Control Unit 2334.86-10 Pumping Stations Double Control Unit for Two Pumps with or without Explosion Protection with Bubbler Control System (Dynamic) DDEL / DSEL from series S-C
More informationTechnical Data. Dimensions
00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationCompact differential pressure switch Flameproof enclosure Ex d Models DE, DEC
Mechatronic pressure measurement Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC WIKA data sheet PV 35.41 Process Compact Series Applications Differential pressure monitoring
More informationPURGEX X Purge Controller E Version. User s Manual
PURGEX X Purge Controller E Version User s Manual This page intentionally left blank Information in this document is subject to change without notice. All terms mentioned in this manual that are known
More informationKSB Delta Compact Type Series Booklet
Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,
More informationPro-V Multivariable Flowmeter Model M22 In-line Vortex
Pro-V Multivariable Flowmeter Model M22 In-line Vortex Pro-V TM Advantage: Volumetric or mass flow monitoring of most liquids, gases, and steam Multivariable meter delivers mass flow, temperature, pressure,
More informationNZQA registered unit standard version 3 Page 1 of 7. Plan electrical installations for explosive atmospheres
Page 1 of 7 Title Plan electrical installations for explosive atmospheres Level 5 Credits 8 Purpose This unit standard is intended for use in the training and assessment of people who work with electrical
More informationProject: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15
PRCEDURES FR RUTINE TESTING F CAPACITR BANKS Consultant : MEP Contractor: Project: PREPARED BY: DRMAN SMITH SWITCHGEAR - DUBAI NAME: REVIEWED BY CNSULTANT : NAME: SIGNATURE: SIGNATURE: Page 1 of 15 Table
More informationThe Omron STI Hazardous Location
Hazardous Location Rating Systems for Interlock Switches The Omron STI Hazardous Location Rated Safety Interlock Switches presented in this catalog are classified by the European standard as Ex, ExdIIc
More informationKSB Delta Compact Type Series Booklet
Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,
More informationCertificate of Conformity
Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocols:
More informationATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502
ATEX, IECEx and MET (Class I, Division 1) Safety Instructions icam502 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
More informationTechnical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up to SIL2 acc. to IEC 61508 Accessories
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More informationAnnex 01 to Certificate IECEx LCI X issue 10
2017-07-29 issue 10 FULL EQUIPMENT DESCRIPTION Application f zone 1: The controller compartment PGC5000A (which controls from one to four Isothermal Ovens type PGC5000B PGC5000C) houses a power supply
More informationTechnical Data. General specifications. Rated operating distance s n 5 mm
0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching
More informationPressure switch, Differential pressure switch and Thermostat RT-E
Data sheet Pressure switch, Differential pressure switch and Thermostat RT-E The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial
More informationPart I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read all instructional
More informationInstructions for Safe Use
Instructions for Safe Use Certification N:o VTT 14 ATEX 041X and IECEx VTT 14.0004X Thank you for choosing SLAM Hornet portable work light with battery back up for your job site. Purpose of this manual
More informationOIL+GAS PRODUCTS AND THEIR APPLICATIONS
OIL+GAS PRODUCTS AND THEIR APPLICATIONS FIELDS OF APPLICATIONS AND REQUIREMENTS OIL RIGS SHIP AND SHIP EQUIPMENT Oil rigs have extremely high requirements for the technology used. Even the smallest spark
More informationRTD temperature probes
RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating
More informationLevel transmitter LT 100
KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationDMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.
Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:
More informationTHERMOSTAT ATEX, Type AMTXs-Ex and AMTXs-Ex/BV Single or double thermostat, rigid rod or capillary exit
THERMOSTAT ATEX, Type AMTXs-Ex and AMTXs-Ex/BV Single or double thermostat, rigid rod or capillary exit Protection by intrinsic safety and by enclosures «i» and «t» For zone 0 (explosive atmospheres due
More informationAK100 Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators
Data sheet DS/AK EN Rev. J AK Series ATEX Compliant Gas Analyzer System for Hydrogen-cooled Alternators Superior technology and quality from the world leader in hydrogen measurement ATEX compliant intrinsically
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 2 mm
0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching
More informationTechnical Data. Dimensions
0102 Model Number Features 6 mm flush Usable up to SIL 3 acc. to IEC 61508 Application Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs,
More informationNZQA registered unit standard version 1 Page 1 of 8. Conduct detailed inspection of electrical installations for explosive atmospheres
Page 1 of 8 Title Conduct detailed inspection of electrical installations for explosive atmospheres Level 5 Credits 5 Purpose This unit standard is intended for use in the training and assessment of people
More informationInductive slot sensor
0102 Model Number Features 3.5 mm slot width Usable up to SIL 3 acc. to IEC 61508 Nonferrous targets Application Danger! In safety-related applications the sensor must be operated with a qualified fail
More informationZ, Y, and X PURGE INDICATORS / CONTROLLERS
PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories
More informationInnovative Techniques for Mitigating Arc Flash Exposure
Innovative Techniques for Mitigating Arc Flash Exposure Presented at MEMSA 2009 Annual Meeting & Technical Symposium 2007 Eaton Corporation. All rights reserved. INTRODUCTION. As more and more industries
More informationExMC15 IECEx certification of non-electrical Ex equipment Summary of how the standards deal with ignition hazard assessment
ExMC15 IECEx certification of non-electrical Ex equipment Summary of how the standards deal with ignition hazard assessment IECEx ExTAG Training Workshop The Hague 2014 Introduction of Non-electrical Ex
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More informationPurgEx. Z Purge Indicator. User s Manual
PurgEx Z Purge Indicator User s Manual This page intentionally left blank Information in this document is subject to change without notice. All terms mentioned in this manual that are known to be trademarks
More informationWillkommen. Welcome to KNF - presentation
Willkommen Welcome to KNF - presentation KNF modular system, way to Project pump heads available in: - aluminium - plastics (PPS, Peek ) - stainless steel - PTFE diaphragms und valves available in: - Neopren
More informationMiniature controls. Contactors. Overload relays. Starters. Control relays
Contactors Overload relays Starters Control relays Description General features Wiring terminations available include plugon connectors, wire pins for PC board mounting and solder connections Low power
More informationMonitoring device NTS 30
P R O D U C T I N F O R M A T I O N Electronic level- and temperature monitoring device Monitoring device NTS 30 Contents Description Description... 2 Operating... 3 Design and electrical data... 4 Circuit
More information120 Series Explosion-Proof Pressure and Differential Pressure Switches
120 Series Explosion-Proof Pressure and Differential Pressure Switches Types J120, J120K, H121, H121K, H122, H122K SIL2 Certified UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please
More informationSafety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85
XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions
More informationLMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.
LMP 07 Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % / 0. % FSO Nominal pressure from 0... mho up to 0... 50 mho Output signals -wire: 4... 0 ma -wire: 0...
More informationPre-Start Ventilation System ML 513
Pre-Start Ventilation System Manual ML 513 Important Note: It is essential for safety that the installer and user of the Expo system follow these instructions. Please refer to the applicable standards
More informationLTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.
LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42
More informationPURGEX X Purge Controller D Version
PURGEX X Purge Controller D Version User s Manual This page intentionally left blank Information in this document is subject to change without notice. All terms mentioned in this manual that are known
More informationDifferential pressure controls, Type MP 54, 55 and 55A
MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors
More informationExplosion proof pressure switch Model: P953 series
Explosion proof pressure switch Model: P953 series Spec. sheet no. PD09-08 Service intended P953 diaphragm type differential pressure switch can be used in a variety of process lines. Internal micro switch
More informationTechnical Datasheet. D Series SMART Pressure Transmitter Model: DPC D-Series. Key Features. Series Overview. Product applications
Technical Datasheet D Series SMART Pressure Transmitter Model: DPC-2000 Key Features ATEX - Flameproof and Intrinsically Safe IECEx - Flameproof and Intrinsically Safe SIL 2 certificate Compliant to NAMUR
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More informationATM.1ST/Ex - High Precision Transmitter
Pressure Transmitter - ATEX / IECEx certified ATM.1ST/Ex - High Precision Transmitter CUSTOMER BENEFITS Certificate: ATEX, IECEx & EAC High measurement accuracy is ensured by sophisticated digital temperature
More informationTechnical Datasheet. Pressure Transmitter: Analogue Series 387. Performance characteristics. Product applications. How can we help you?
Technical Datasheet Pressure Transmitter: Analogue Series 387 387 ISSUE G High Accuracy ± 0.15%. Ranges from 1 bar to 1000 bar. 4 : 1 turndown. 4-20mA analogue with digital communications. 316 stainless
More informationThermo Probe, Inc. TP-5 TP-7 TP-8. Instruction Manual English. Switch. Display. Carry Strap. Probe. Ground Clip. Switch. Display.
Display Thermo, Inc. Instruction Manual English TP-5 Display TP-7 Display TP-8 1-1 Thermo, Inc. Instructions for use- Models TP-5, TP-7, and TP-8 The manual describes basic function and use of Thermo instruments
More informationIntrinsically explosion-proof and safety barrier introduction
Intrinsically explosion-proof and safety barrier introduction Summary of Topics Page 1. Explosion basic knowledge 1 2. Explosion groups 1 3. Zone classification 2 4. Explosion-proof electrical apparatus
More informationUltra High Purity Model 780S
Smart Ultra High Purity Thermal Gas Mass Flow Meter Features Measures mass flow directly, no separate temperature or pressure inputs required Built-in flow conditioner which eliminates velocity-profile
More informationFloodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN
Floodlight LED Operating instructions Additional languages www.stahl-ex.com General Information Contents 1 General Information...2 1.1 Manufacturer...2 1.2 Information regarding the operating instructions...3
More informationArran LED Floodlight Luminaire
Arran LED Floodlight Luminaire INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment. Good electrical
More informationPressure & Temperature Switches
Pressure & Temperature Switches The User Friendly Generation General Bulletin TEMPERATURE SWITCHES BETA TEMPERATURE SWITCH The BETA Temperature Switch is a pressure switch incorporating a sealed 2-phase
More informationPressure Measurement Single-range transmitters for general applications
Siemens AG 07 Overview Function U const. p U I EM Sensor Connection for auxiliary power supply Vent pipe with humidity filter Protective conductor connection/ Equipotential bonding Diaphragm The pressure
More informationEarth-Rite RTR. Leading the way in hazardous area static control. Static Grounding for Road Tankers. IECEx SIL 2
Earth-Rite RTR Static Grounding for Road Tankers ATEX IECEx SIL 2 Precision and reliability is what the Earth-Rite RTR provides to QHSE professionals and engineers who are tasked with protecting personnel
More informationPushbuttons, Indicating Light, and Rotary Switch Stations Series 4975
Series 4975 Series 4975 Pushbutton Stations are designed for shipboard control applications requiring heavy duty watertight master switches. Stations are available with one, two or three elements equipped
More information