Column w/laterals. Steel Column A992 50ksi Steel. 1 Rev
|
|
- Audrey Holland
- 5 years ago
- Views:
Transcription
1 olumn w/ SOREOR HEIGHT WITH ddtional display area consisting signs, arches, message centers or video above or below the scoreboard. (see sheets 7) for column and pier sizing) Equal TOP SOREOR SETION OTTOM SOREOR SETION 0' (to bottom lowest display component) "" (center to center) Equal Overall isplay Height SOREOR IMENSIONS N SPEIFITIONS MOEL WITH HEIGHT WEIGHT WEIGHT Max "" Min "" W/ETN 60 8' 8' /6" ' ' 606, 65, 67, 68, 69, , 76 ' 8' /6" ' ' 685,7685 ' 8' /6" N/ 70 6' ' 7605, 765, 765 ' 0' 6 9/" ' ' 860, 860 ' 8' /6" ' ' ' 0' 8' /6" 8' /6" 50 N/ ' 8' ' ' General Notes:. olumn steel to be grade 99 (50 ksi steel minimum).. racing steel to be STM 500 Grade minimum (see 05).. Minimum bolt grade: 07. ll welds to conform to WS standards 5. The dimensions in the charts on sheets 7 are calculated using the requirements specified in I 0, and the Manual Steel onstruction (th Edition). Soil lateral bearing pressure is considered to be 50 psf/f. 6. heck with the local building authority to determine the installation sites wind zone and risk category as specified in I 0 and SE 70. For the purposes these installation prints, Risk ategory I shall apply to an installation where the scoreboard is more than.5 x the overall height away from the nearest spectator section. Risk ategory II shall apply to all other installations. 7. The weights signs to be calculated using. lb/sq. ft sign area. 8. The weights Nevco message centers to be calculated using 8.5 lb/sq ft. 9. The weights Nevco video displays to be calculated using 9.5 lbs/sq. ft. 0. The weights Nevco arches to be calculated using 7.7 lbs/sq. ft. heck electrical prints to determine conduit sizes (must meet code) Pier epth (see sheets 9) Steel olumn 99 50ksi Steel (see sheets 9) oncrete must slope away from columns oarse aggregate concrete (fc = 500 psi minimum) Important. Read before installation. This is not an engineered drawing. It is intended for representational purposes only. The dimensions called out on this drawing are intended to be used as a guide only, and are not intended to be suitable for all conditions. dding signs or other components around the scoreboard beyond the scope this drawing or increasing the display height from the ground will affect the installation requirements. Nevco recommends that you consult a pressional engineer or architect familiar with the area before attempting installation. They can verify that the selected mounting beams or posts along with the brackets, screws, and other hardware items provided by others or Nevco are adequate for your local soil conditions, wind loads and other local codes. If procedures are used that are not covered in this drawing, careful analysis the installation is urged. 6" From end column to edge concrete Pier iameter (see sheets 9) FRONT VIEW rawn / olumn With K ate /5/0 rawing No. Greenville, Illinois
2 olumn w/ WITH ddtional display area consisting signs, arches, message centers or video above or below the scoreboard. (see sheets 7) for column and pier sizing) SOREOR IMENSIONS N SPEIFITIONS Model WITH HEIGHT WEIGHT WEIGHT MX "" MIN "" W/ETN 60 6' 9' /6" ' ' 66, 766 6' 0' /6" ' ' 657 ' 0' /6" ' ' 688 ' 8' /6" N/ 90 ' ' 60, 760 ' 8' /6" ' ' HEIGHT Equal "" (center to center) Top Scoreboard Section ottom Scoreboard Section "" (center to center) Equal Overall isplay Height General Notes:. olumn steel to be grade 99 (50 ksi steel minimum).. racing steel to be STM 500 Grade minimum (see 05).. Minimum bolt grade: 07. ll welds to conform to WS standards 5. The dimensions in the charts on sheets 7 are calculated using the requirements specified in I 0, and the Manual Steel onstruction (th Edition). Soil lateral bearing pressure is considered to be 50 psf/f. 6. heck with the local building authority to determine the installation sites wind zone and risk category as specified in I 0 and SE 70. For the purposes these installation prints, Risk ategory I shall apply to an installation where the scoreboard is more than.5 x the overall height away from the nearest spectator section. Risk ategory II shall apply to all other installations. 7. The weights signs to be calculated using. lb/sq. ft sign area. 8. The weights Nevco message centers to be calculated using 8.5 lb/sq ft. 9. The weights Nevco video displays to be calculated using 9.5 lbs/sq. ft. 0. The weights Nevco arches to be calculated using 7.7 lbs/sq. ft. heck electrical prints to determine conduit sizes (must meet code) Pier epth (see sheets 7) 0' pprox. (to bottom lowest display component) Steel olumn 99 50ksi Steel (see sheets 7) oncrete must slope away from columns Ground Level Important. Read before installation. This is not an engineered drawing. It is intended for representational purposes only. The dimensions called out on this drawing are intended to be used as a guide only, and are not intended to be suitable for all conditions. dding signs or other components around the scoreboard beyond the scope this drawing or increasing the display height from the ground will affect the installation requirements. Nevco recommends that you consult a pressional engineer or architect familiar with the area before attempting installation. They can verify that the selected mounting beams or posts along with the brackets, screws, and other hardware items provided by others or Nevco are adequate for your local soil conditions, wind loads and other local codes. If procedures are used that are not covered in this drawing, careful analysis the installation is urged. 6" From end column to edge concrete Pier iameter (see sheets 7) FRONT VIEW oarse aggregate concrete (fc = 500 psi) rawn / olumn With K ate /5/0 rawing No. Greenville, Illinois
3 05 MPH WIN ZONES 0 FEET WIE ( OLUMNS) 0 MPH WIN ZONES 0 FEET WIE ( OLUMNS) 0 MPH WIN ZONES 0 FEET WIE ( OLUMNS) hart Notes:. If the display height is between chart values shown above, use the next highest value.. * It is required that xx/6 steel tubing be welded to back columns 0' from the ground and every 0' to the top the column for bracing. (See detail on 05).. Wind loading figured at Exposure "" Open terrain with scattered obstructions having heights generally less than 0 feet. This category includes flat open country, grasslands, and all water surfaces in hurricane. Wind loading figured at Exposure "" Urban and suburban areas, wooded areas, or other terrain with numerous closely spaced obstructions having the size singlefamily dwellings or larger. These areas prevail in the upwind direction for a distance 600 feet or 0 times the structure height, whichever is greater. rawn / olumn With ate rawing No. K /5/0 9 Greenville, Illinois
4 50 MPH WIN ZONES 0 FEET WIE ( OLUMNS) 80 MPH WIN ZONES 0 FEET WIE ( OLUMNS) / olumn With rawing No. Greenville, Illinois rawn ate K /5/0 9
5 05 MPH WIN ZONES FEET WIE ( OLUMNS) 8 FEET WIE ( OLUMNS) FEET WIE ( OLUMNS) 6 FEET WIE ( OLUMNS) hart Notes:. If the display height is between chart values shown above, use the next highest value.. * It is required that xx/6 steel tubing be welded to back columns 0' from the ground and every 0' to the top the column for bracing. (See detail on 05).. Wind loading figured at Exposure "" Open terrain with scattered obstructions having heights generally less than 0 feet. This category includes flat open country, grasslands, and all water surfaces in hurricane. Wind loading figured at Exposure "" Urban and suburban areas, wooded areas, or other terrain with numerous closely spaced obstructions having the size singlefamily dwellings or larger. These areas prevail in the upwind direction for a distance 600 feet or 0 times the structure height, whichever is greater. rawn / olumn With K ate rawing No. Greenville, Illinois 66 /5/
6 0 MPH WIN ZONES FEET WIE ( OLUMNS) 8 FEET WIE ( OLUMNS) FEET WIE ( OLUMNS) 6 FEET WIE ( OLUMNS) hart Notes:. If the display height is between chart values shown above, use the next highest value.. * It is required that xx/6 steel tubing be welded to back columns 0' from the ground and every 0' to the top the column for bracing. (See detail on sheet 7). Wind loading figured at Exposure "" Open terrain with scattered obstructions having heights generally less than 0 feet. This category includes flat open country, grasslands, and all water surfaces in hurricane. Wind loading figured at Exposure "" Urban and suburban areas, wooded areas, or other terrain with numerous closely spaced obstructions having the size singlefamily dwellings or larger. These areas prevail in the upwind direction for a distance 600 feet or 0 times the structure height, whichever is greater. rawn / olumn With K ate /5/0 rawing No. Greenville, Illinois
7 0 MPH WIN ZONES FEET WIE ( OLUMNS) 8 FEET WIE ( OLUMNS) FEET WIE ( OLUMNS) 6 FEET WIE ( OLUMNS) hart Notes:. If the display height is between chart values shown above, use the next highest value.. * It is required that xx/6 steel tubing be welded to back columns 0' from the ground and every 0' to the top the column for bracing. (See detail on 05).. Wind loading figured at Exposure "" Open terrain with scattered obstructions having heights generally less than 0 feet. This category includes flat open country, grasslands, and all water surfaces in hurricane. Wind loading figured at Exposure "" Urban and suburban areas, wooded areas, or other terrain with numerous closely spaced obstructions having the size singlefamily dwellings or larger. These areas prevail in the upwind direction for a distance 600 feet or 0 times the structure height, whichever is greater. rawn / olumn With K ate /5/0 rawing No. Greenville, Illinois
8 50 MPH WIN ZONES FEET WIE ( OLUMNS) 8 FEET WIE ( OLUMNS) FEET WIE ( OLUMNS) 6 FEET WIE ( OLUMNS) hart Notes:. If the display height is between chart values shown above, use the next highest value.. * It is required that xx/6 steel tubing be welded to back columns 0' from the ground and every 0' to the top the column for bracing. (See detail on 05).. Wind loading figured at Exposure "" Open terrain with scattered obstructions having heights generally less than 0 feet. This category includes flat open country, grasslands, and all water surfaces in hurricane. Wind loading figured at Exposure "" Urban and suburban areas, wooded areas, or other terrain with numerous closely spaced obstructions having the size singlefamily dwellings or larger. These areas prevail in the upwind direction for a distance 600 feet or 0 times the structure height, whichever is greater. rawn / olumn With K ate /5/0 rawing No. Greenville, Illinois
9 80 MPH WIN ZONES FEET WIE ( OLUMNS) 8 FEET WIE ( OLUMNS) FEET WIE ( OLUMNS) 6 FEET WIE ( OLUMNS) hart Notes:. If the display height is between chart values shown above, use the next highest value.. * It is required that xx/6 steel tubing be welded to back columns 0' from the ground and every 0' to the top the column for bracing. (See detail on 05).. Wind loading figured at Exposure "" Open terrain with scattered obstructions having heights generally less than 0 feet. This category includes flat open country, grasslands, and all water surfaces in hurricane. Wind loading figured at Exposure "" Urban and suburban areas, wooded areas, or other terrain with numerous closely spaced obstructions having the size singlefamily dwellings or larger. These areas prevail in the upwind direction for a distance 600 feet or 0 times the structure height, whichever is greater. rawn / olumn With K ate /5/0 rawing No. Greenville, Illinois
Method of Test for Flat & Elongated Particles
Method of Test for Flat & Elongated Particles 1. Scope: This test is for determining the percentage by weight of coarse aggregate that have a maximum to minimum dimension greater than the specified ratio
More informationAnchor Component Material Standard Mechanical Properties
SECTION 4.1 PAGE 1 / 5 l description The UCAN sleeve anchor is a light-medium duty anchor ideal for applications in concrete, hollow block and brick. It is a mechanical expansion anchor assembled with
More information6.0 ENGINEERING. Build Anything Better. REPRINTED 2017
6.0 ENGINEERING TABLE OF CONTENTS 6.1 U.S. ENGINEERING ANALYSIS REPORT... P. 6-3 BELOW-GRADE WALL REINFORCEMENT TABLES... P. 6-5 ABOVE-GRADE WALL REINFORCEMENT TABLES.. P. 6-21 LINTEL REINFORCEMENT TABLES...P.
More informationSTRUCTURAL DESIGN FIGURE INTERNATIONAL BUILDING CODE 288aR
FIGURE 1609.1 288aR 288bR 1609.1.4.1 Building with openings. Where glazing is assumed to be an opening in accordance with Section 1609.1.4, the building shall be evaluated to determine if the openings
More informationREVIEW ALL INSTALLATION NOTES PRIOR TO INSTALLATION!
Page 1 of 7 HD NON-PENETRATING ROOF MOUNT ASSEMBLY INSTRUCTIONS REVIEW ALL INSTALLATION NOTES PRIOR TO INSTALLATION! INSTALLATION NOTES General 1) These general structural notes are intended to augment
More informationCode Compliance Research Report CCRR-0145
Code Compliance Research Report CCRR-0145 Issue Date: 11-16-2009 Revision Date: 11-29-2018 Renewal Date: 11-18-2019 DIVISION: 05 - Metals Section: 05 50 00 Metal Fabrications Marshall Stamping Company
More informationRSL TOWER KITS RSLL-01-A1 RSL GENERAL NOTES
SECTION P/N R10H R9H R8H R7 R6 R5 R4 R3 R R1 LENGTH RSLL-1 RSLL- RSLL-3 RSLL-4 RSLL-5 RSLL-6 RSLL-7 RSLL-8 U 3/4" X 1/4" (U 70 X 6.4 mm) RSLL-9 U 3/4" X 1/4" (U 70 X 6.4 mm) RSLL-10 U 3/4" X 1/4" (U 70
More informationCOMPFIRE CCFT-FP_550_55_ September 2010 Fin Plate Connection to Circular Concrete-Filled Tube Test Result
Reaction Frame Macalloy Bars Camera 3 Support Beam α Oven Bar Camera 2 Link Bar Camera 1 Tested Connection Jack Bar Electrical Furnace Reaction Frame Load Jack v2_5 April 2011 1 Oven Bar Link Bar View
More informationPerformance Outline Specifications
ATHLETIC FIELD LIGHTING SYSTEMS Performance Outline Specifications Revision 3.3 July 28, 2010 Table of Contents SPECIFICATIONS 1.0 APPLICABILITY... Page 2 2.0 GENERAL DESIGN CRITERIA...2 3.0 ELECTRICAL
More informationNORDEX. Foundations. Nordex N117/3000
Foundations Nordex N117/3000 Nordex Energy GmbH, Langenhorner Chaussee 600, 22419 Hamburg, Germany All rights reserved. Observe protection notice ISO 16016. K0801_042963_EN Revision 00, 2013-02-04 1 /
More informationOPERATOR S MANUAL AND PARTS LISTING FOR THE. STM Mounted Harrow
MANUFACTURERS OF QUALITY AGRICULTURAL EQUIPMENT SINCE 1936 OPERATOR S MANUAL AND PARTS LISTING FOR THE STM Mounted Harrow With FH 5-Bar Section VERSION: 10-07AJF TO THE OWNER AND OPERATORS Before assembling
More information1 Exam Prep. Tabs and Highlights
1 Exam Prep NFPA 14: Standard for the Installation of Standpipe and Hose Systems Tabs and s These 1 Exam Prep tabs are based on the NFPA 14: Standard for the Installation of Standpipe and Hose Systems,
More informationLOK-BOLT AS. Mechanical Anchors GENERAL INFORMATION SECTION CONTENTS. Sleeve Anchor
General Information Mechanical s GENERAL INFORMATION LOK-BOLT AS Sleeve PRODUCT DESCRIPTION The Lok-Bolt AS is an all-steel pre-assemble single unit sleeve anchor which is esigne for use in concrete or
More informationBOUNDARY Deer & Perimeter Fence
Three-Part Specifications - Copyright 2015 - Nixalite of America Inc BOUNDARY Deer & Perimeter Fence Includes specifications for: BOUNDARY Lightweight, Standard, Extra Tall, Extra Strength and Maximum
More informationBridge Design Preliminary Bridge Design Example 1 / 6 Spring 2012 updated 1/27/2012
Bridge Design Preliminary Bridge Design Example 1 / 6 Perform a preliminary design for a bridge on a state highway over a large creek in rural Alabama. Produce a construction layout drawing showing profile
More informationSub-Base Assembly For Type-ML 32 & VR-1 Step Voltage Regulator Single-Phase Liquid-Filled Part # GEK 35171
Transformer Business Department Regulator & Inductive Products Sub-Base Assembly For Type-ML 32 & VR-1 Step Voltage Regulator Single-Phase Liquid-Filled Part # GEK 35171 Last Update 11-19-2013 Tom Dauzat,
More informationMini Channel & Fittings
Our mini channels and fittings provide for an economical method of supporting light load requirements on a strut system. Channel Channels are cold formed on our modern rolling mills from 18 Ga. (1.2 mm)
More informationEZ SERIES FIXED ACCESS LADDERS
EZ SERIES FIXED ACCESS LADDERS Engineered from the ground up for OSHA 1910.3 COMPLIANCE Installs in three easy steps 1 ATTACH MOUNTING BRACKETS PLACE RUNG IN BRACKET 3 SECURE WITH BOLTON CAPTURE PLATE
More informationHardened Steel Washers
USS (Type A Wide) Flat Washers Hardened Steel Washers Grade 8 S.A.E. Dimensions American Standard Lbs. Per No./Pcs. Gauge M Pcs. Per Lb. 3/16 9/16 1/4 18 (3/64) 2.8 361 1/4 3/4 5/16 16 (1/16) 6.7 149 5/16
More informationBollard Post, Model R-8902
ollard Post, Model R-80 Removable Receiver with Lid (for detail, see sheet of ) Removable Receiver with hain (for detail, see sheet of ) Fixed Embedded Mount (for detail, see sheet of ) Flanged Surface
More informationNEW PORCH 162 SQ. FT ENCROACHMENT INTO YARD SET BACKS C L WALL 8'-0"
PROPERTY LINE WHEELCHAIR LIFT 0' FRONT YARD ST FL. RADIATOR 2ND FL. 2'-7 /2"x4'-8" 2'-7 /2"x4'-8" 9'-3 2 " '-5 4 " 2'-7 /2"x4'-8" 2'-7 /2"x4'-8" '-6" 2'-0 2 " 6'-0" 5'-5" 3'-3 2 " 2'-" 3'-9" 5'-2" PLUMBING
More informationImpact of New ANSI/TIA-222-H Standard on Broadcast NAB * ERI Breakfast * Apr 11, 2018 James Ruedlinger, P.E
Impact of New ANSI/TIA-222-H Standard on Broadcast 2018 NAB * ERI Breakfast * Apr 11, 2018 James Ruedlinger, P.E Adoption ANSI/TIA-222 REV H: Current industry consensus standard Effective January 1, 2018
More informationFlow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS880 (retrofit kit) 4/275. Overview
Siemens G 2010 Overview pplication Irrigation systems Irrigation distribution systems Pumping stations Canal laterals On-farm outlets Water well production rip and sprinkler irrigation Center pivot systems
More informationHand & mechanical directional valves
www.atos.com Table E5-3/E Hand & mechanical directional valves ISO 44 sizes 6,, 6 and 25 H- Hand & mechanical operated directional valves are spool type, three or four way, two or three position valves,
More informationLoads on Structures. Dead Load / Fixed Load Live Load / Imposed Load Earthquake Load Wind Load Snow Load
Loads on Structures Dead Load / Fixed Load Live Load / Imposed Load Earthquake Load Wind Load Snow Load Characteristics of Wind Load Depends upon - velocity and density of the air height above ground level
More informationVibration isolation system 1VIS10W. User manual
Vibration isolation system 1VIS10W User manual Standa 2014 Table of contents 1. General information 3 1.1. Introduction 3 1.1.1. Safety 5 1.2. Location of the table 5 1.3. Air supply requirements 5 2.
More informationTV-114 TV-114-A Wind Speed Sensor User s Manual
Relied on Worldwide in the Most Extreme Conditions TV-114 TV-114-A Wind Speed Sensor User s Manual Texas Electronics, Inc. Dallas, TX 75237 Fax.214.631.4218 4230 Shilling Way Tel.214-631-2490 www.texaselectronics.com
More informationMODEL 9875 STADIUM BASEBALL SCOREBOARD. Instruction Manual
UNITEC MANUFACTURING DIVISION MODEL 9875 STADIUM BASEBALL SCOREBOARD (WITH INNING BY INNING SCORING) Instruction Manual Mailing Address: PO Box 260, Yorkville, NY 13495-0260 Plant Address: 34 Main Street,
More informationl DESCRIPTION l FEATURES l LIMITATIONS l TYPICAL APPLICATIONS l MATERIAL SPECIFICATIONS TECHNICAL MANUAL SECTION 2.3 PAGE 1 / 6
www.ucanfast.com TECHNICAL MANUAL SECTION 2.3 PAGE 1 / 6 l DESCRIPTION The UCAN WAG anchor is a fully threaded torque controlled expansion anchor assembled with a three segment expansion clip. All parts
More informationAN Wireless Tower Assembly Instructions
N Wireless Tower ssembly Instructions RED THOROUGHLY EFORE SSEMLY ND ERETION Thank you for your purchase of an N Wireless Self Supporting Tower. N Wireless Towers are designed and fabricated to be high-strength,
More informationCode Compliance Research Report CCRR-0145
Code Compliance Research Report CCRR-0145 Issued: 11-16-2009 Renewal Due: 11-18-2018 Revised: 11-28-2017 DIVISION: 05 - Metals Section: 05 50 00 Metal Fabrications MARSHALL STAMPING COMPANY 355 Glade Mills
More informationTABLE OF CONTENTS PRODUCTS & INFORMATION
SHORING CATALO G TABLE OF CONTENTS PRODUCTS & INFORMATION PAGE HL SHORING FRAMES (10k/leg)...3 STEEL SHORING ACCESSORIES... 4 SHORING TOWER... 5 SHORING JACK... 6 SHORING FRAME ALLOWABLE WORKING LOADS...7
More informationDBI SALA Advanced Hoist Systems
DBI SALA 8518008 Advanced Hoist Systems CONTENTS History of Unique Concepts Limited... 2 Uni-Anchor Plates & Lugs... 3 Portable Uni-Anchor & Beam Clamp... 3 Mast Assembly... 4 Options... 5 Features...
More informationCE 535, Spring 2002 Preliminary Design Example 1 / 6
CE 535, Spring 2002 Preliminary Design Example 1 / 6 Perform a preliminary design for a bridge on a state highway over a large creek in rural Alabama. Produce a construction layout drawing showing profile
More informationGRAVITY BIKE RACK ASSEMBLY & OPERATING INSTRUCTIONS
GRAVITY BIKE RACK 94479 ASSEMBLY & OPERATING INSTRUCTIONS Due to continuing improvement, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo, CA 93011
More information1 & 3 Meter Tower CAT 1M 203R RIGHT MOUNT CAT 3M 203R CAT 1M 203L LEFT MOUNT CAT 3M 203L CAT 1M 203D DUAL MOUNT CAT 3M 203D
1 & 3 Meter Tower CAT 1M 203R RIGHT MOUNT CAT 3M 203R CAT 1M 203L LEFT MOUNT CAT 3M 203L CAT 1M 203D DUAL MOUNT CAT 3M 203D CAT 1M 203H HEEL MOUNT CAT 3M 203H WARNING CAUTION: DIVING BOARD AND TOWER COMBINATIONS
More informationARCHITECTURAL GUIDELINES FOUR-PIECE COMMERCIAL
ARCHITECTURAL GUIDELINES FOUR-PIECE COMMERCIAL ARCHITECT GUIDELINES FOR SWIMEX FOUR-PIECE COMMERCIAL INSTALLATION GENERAL LAYOUT Call SwimEx at 800-877-7946 to receive AutoCad Drawings of the SwimEx Model
More informationSide-of-Pole Mount for 1 Module (SPM1) For Module Types A & B
Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B ASSEMBLY INSTRUCTIONS step-by-step assembly and installation Version 1, Rev A PCN 080311-2 SP3363-1 Side-of-Pole Mount for 1 Module (SPM1)
More informationAWWA Pipe Flanges. AWWA C Standard Steel Hub Flanges Class D AWWA C Standard Steel Hub Flanges Class E AWWA C Flange Manufacturer
WW Pipe Flanges WW Flanges are commonly used in waterworks, wastewater, slurry, plant piping or other light duty applications generally requiring pressures of less than 300 psi. Pressure ratings for WW
More informationMarine 6-Boat Free-Standing Racks SKU: Updated November 2011
Marine 6-Boat Free-Standing Racks SKU: 30-061 Updated November 011 Contains: Marine -Boat Free-Standing Racks (SKU 1-003) Marine 3 rd Boat Expansion Racks (SKU 1-0303) Marine Back Legs (SKU -001) 3 Sets
More informationProduct Specifications Specialty Junction Boxes
NOVA Energy & Automation Product Specifications Specialty Junction Boxes Model JB 03 January 2012 Product Description 1. Specialty Junction Boxes Nova Junction Boxes are custom manufactured by size, material,
More informationOperator s/parts Manual
Operator s/parts Manual 24 & 30 Folding No-Till Drill Harrow Manufacturing, Inc. P.O. Box 5060 Salina, Kansas 67402-5060! Read the Operator s manual entirely. When you see this symbol, the subsequent instructions
More informationW60 Spool & Sleeve Valves for ISO Bases (5599/I)
W60 Spool & Sleeve Valves for ases (59/I) 5/ Valves Single Solenoid Pilot Spring Return,7,,6 W60760 W6076 W60760 W6076 W60760 W6076 W6070 W607 * ase and electrical connector not included. 5/ Valves Double
More informationV-PLOW. ACCUFLO Conveyor Belt Cleaning System MAX SYSTEMS GUIDE. Engineering. LIB-CP-SYS-01-E Rev.9. Page 1
ACCUFLO Conveyor Belt Cleaning System Page 1 Conveyor Belt Cleaning System - System Nomenclature CATGORY MAINFRAM INFORMATION BLAD INFORMATION CP=CONVYOR PRODUCTS CP - PA - 36 M - G 83 SYSTM TYP BLT WIDTH
More information2010 STANDARD SPECIFICATIONS STANDARD DRAWINGS
CITY OF REDMOND, OREGON 2010 STANDARD SPECIFICATIONS STANDARD DRAWINGS TABLE OF CONTENTS SECTION 1 TRENCHES TITLE 1-1 Utility Trench 1-2 Water Line & Sewer Line Separation 1-3 RR X-ING Single/Joint Use
More informationGANTRY CRANES CAPACITIES: SPANS: TRACKS: OPTIONS: Up to 5 tons Up to 30' Steel Fixed or Adjustable
GANTRY CRANES CAPACITIES: SPANS: TRACKS: OPTIONS: Up to 5 tons Up to 30' Steel Fixed or Adjustable Material Handling Solutions For Your Unique Applications Since 1977, Gorbel has been an innovator and
More informationDuke Street (Route 236) Over I Bridge Plan & Elevation
Duke Street (Route 236) Over I-395 - ridge Plan & Elevation ity of Alexandria Exist. sign structure supports on bridge fascia to be removed in 395 express lanes project Abutment A Sta. 102+03.02 E 41-1"
More informationHoist Ring Forged Hoist Ring Machined Hoist Ring (Metric) Hoist Ring Swivel Shoulder Eyebolts JD Weld-On Alloy Lifting
Hoist Ring Forged........................... 94 Hoist Ring Machined........................ 95 Hoist Ring (Metric).......................... 96 Hoist Ring Swivel........................... 97 Shoulder
More informationDOCUMENT DESPATCH ADVICE Ref: MED 16 :1/T- 6 Date:
RAFT TANAR IN WIE IRUATION OUMENT EPATH AVIE Ref: ME 16 :1/T- 6 ate: 18-2-215 Gas ylinders, ectional ommittee, ME 16 TO: a) The interested members of Mechanical Engineering ivision ouncil, ME b) All members
More informationBP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS
BP48-1 AND SSP48-1 IN-GROUND POST INSTALLATION INSTRUCTIONS WARNING: THIS IN-GROUND POST IS NOT DESIGNED FOR USE WITH AN LP GAS CYLINDER. WARNING: SEE YOUR GRILL OWNER S MANUAL FOR PROPER LOCATION, MINIMUM
More informationAir Distribution Corporation Spiral Duct and Fittings are manufactured in accordance with applicable SMACNA, ASHRAE and SPIDA standards.
ir istribution orporation Spiral uct and Fittings onstruction Standards ir istribution orporation Spiral uct and Fittings are manufactured in accordance with applicable SMN, SRE and SPI standards. Galvanized
More informationSae 4 Bolt Flange Port Dimensions
We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with sae 4 bolt flange port
More informationHow to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø
Series RM/ End lock RME Port Plug End block End block type Mounting position L Left side R Right side L side end block 0. L VVQ0000 Single unit regulator / Port plug for regulator block ø0 0 Options Note
More informationARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL
ARCHITECTURAL GUIDELINES FOUR-PIECE RESIDENTIAL Architect Installation Guidelines for Four-Piece Residential Installations GENERAL LAYOUT Call SwimEx at 800-877-7946 to receive AutoCad Drawings of the
More informationSTATIONARY TRUCK INTERNAL HALYARD V-CLEAT FLAGPOLES FOR QUICK AND PROFESSIONAL INSTALLATION READ ALL INSTRUCTIONS BEFORE PROCEEDING
9390 South 300 West, Sandy, Utah 84070 801-562-0123 800-782-0500 ColonialFlag.com STATIONARY TRUCK INTERNAL HALYARD V-CLEAT FLAGPOLES FOR QUICK AND PROFESSIONAL INSTALLATION READ ALL INSTRUCTIONS BEFORE
More informationSIGN PLACEMENT-ELEVATION VIEW: FREEWAY (FORESLOPE) ROADSIDE SIGN LOCATIONS & SUPPORT SPACING MICHIGAN DEPARTMENT OF TRANSPORTATION (MIN.
3' HINGE POINT EACH POST (TYP) (MIN.) (SAW CUT OR FUSE PLATE) EDGE OF FORESLOPE 4" STEEL COLUMN 6" WOOD POST THRU TRAVELED 7'MIN. SHOULDER LATERAL OFFSET (FORESLOPE) (VARIABLE) BREAKA POSTS THE LATERAL
More informationModel AWG20 AWG30 AWG40 AWG20K AWG30K AWG40K
Modular Type ilter Regulator with uilt-in Pressure auge eries W ilter Regulator with uilt-in Pressure auge eries W ominal filtration rating ccessory W2 /8, /4 W3 /4, 3/8 W /4, 3/8, /2 racket Pages 424
More informationSide-of-Pole Mount for 1 Module (SPM1) For Module Type C
Module Type Width Length C 22-27 56-63 Side-of-Pole Mount for 1 Module (SPM1) For Module Type C ASSEMBLY INSTRUCTIONS step-by-step assembly and installation Version 1, Rev A PCN 022212-1 Side-of-Pole Mount
More informationGUMMIKOMPENSATOR GKF8000 / GKF8130
GUMMIKOMPENSATOR GKF8000 / GKF8 Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications
More informationMaterials : Galvanized steel flanges
Size : Ends : Min Temperature : Max Temperature : DN 32 to 200 Flanges PN10/16-10 C + 80 C Max Pressure : 16 Bars Specifications : Absorb vibrations and noises Linear and angular compansion Single NBR
More informationOPERATOR S MANUAL AND PARTS LISTING FOR THE. CTM Series Mounted Harrow
MANUFACTURERS OF QUALITY AGRICULTURAL EQUIPMENT SINCE 1936 OPERATOR S MANUAL AND PARTS LISTING FOR THE CTM Series Mounted Harrow VERSION: 7-12 (MM-2300) TO THE OWNER AND OPERATORS Before assembling or
More informationProduct Identification
Product Identification All SCAFCO products have a four part identification code which identifies the size (both depth and flange width), style, and material thickness of each member. Example: Member Depth:
More informationTRU-WELD Stud Welding
HEAE CONCRETE ANCHOR FU WE BASE TYPE CA STU TYPE F FERRUE SUPPIE Head iameter (H) 1/2 for all 1/4 Headed Concrete Anchors. Head Height (HT) 3/16 for all 1/4 Headed Concrete Anchors. iameter ength TRU WE
More informationWIND LOADING DESIGN GUIDE
APPLICATION ENGINEERING / WIND LOADS FEATURES WIND PRESSURE / TERRAIN CATEGORY / LOCAL PRESSURE / AS/NZS1170.2:2011 FREE CALL 13000 ASKIN or Email: contact@askin.net.au Date: JULY 2015 Telephone: 13000
More informationTYPE: LSF - LIFTING STUD FOOT ANCHOR DESCRIPTION: The design of the anchor means no additional reinforcement is required as the forces are transferred into the concrete from the design of the foot of the
More informationASME Boiler & Pressure Vessel Code Analysis of the 1497 MHz High-Current Cryomodule Helium Vessel
1.0 Introduction ASME Boiler & Pressure Vessel Code Analysis of the 1497 MHz High-Current Cryomodule Helium Vessel Katherine Wilson 28 May 2007 To minimize the hazards associated with vacuum and pressure
More informationContinental Industries STEEL SERVICE TEES or FAX Visit
Continental Industries STEEL SERVICE TEES 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and
More informationPSSS-Straight Square Steel Poles, 4", 5" FINISH
PSSS-Straight Square Steel s, ", " CATALOG NUMER: FIXTURE TYPE: PROJECT: POLE SPECIFICATIONS Conforms to ASTM-A 00 Grade : Minimum Yield Strength of 6,000 PSI. Wall Thickness Available in 11 Gauge (. )
More information660 Multipoint Electronic Level Switch
660 Multipoint Electronic Level Switch General Instructions The Multipoint Electronic Level Switch is a level sensing device which reads process level by capacitance measurement. Capacitance varies according
More informationMinimum Standards for Driveway Construction Village of Bear Creek
Minimum Standards for Driveway Construction Village of Bear Creek An exception to the following requirements may only be granted by city council. The needs of each drainage system are considered independently,
More information400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO
400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand
More informationMfg. No: Grass Catcher, Single Bag (Export)
Parts Manual Mfg. No: 7600237 Grass Catcher, Single Bag (Export) Copyright Briggs and Stratton. All Rights reserved 01-Apr-2019 Model Components Table Of Contents Page Single Catcher........................................................................................
More informationRepair instructions. Pivot bushing replacement. XL-AS10001RM-en-DE Rev B
Repair instructions Pivot bushing replacement XL-AS10001RM-en-DE Rev B Table of contents Table of contents 1 General information... 3 1.1 Safety information...3 1.2 Legal information...4 1.3 Order and
More informationDifferential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN
Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................
More informationADA Operations Contact Info
Intro ADA Operations Contact Info Todd Grugel ph: 651-366-3531 email: todd.grugel@state.mn.us Joe Zilka ph: 651-366-3311 email: joseph.zilka@state.mn.us Harvey Unruh ph: 651-216-2912 email: harvey.unruh@state.mn.us
More informationProgress Report on the Design and Planning of an Infrastructure Improvement Project for the Sunnyside TIF District (Phase II)
Presentation to the CNRC Board of Directors Regular Meeting March 11, 2015 1 Agenda Preferred Alternate Refinement for University Avenue, 3rd Street, and Beverly Avenue Intersection Improvements validate
More informationTRUELINE. RAILing. Professional Railing Experts
2 1 4" Wide Picket Top Rail 5 8" x 5 8" Pickets Welded To Top Rail and Picket Channel "A" 42" TOP MOUNT PICKET 3 1/4" Gap Comes With Round 4"x4"x 1 4" Base Plate Screwed To Post Mount W/ (4) 1 4" Stainless
More informationType 3 - PSA Nitrogen Generation System
Type 3 - PSA Nitrogen Generation System Designed for: Dry or Pre-Action Fire Protection Systems (FPS) with a total capacity from 6,000 to 18,000 gallons 1.0 Nitrogen Generation Corrosion Inhibiting System
More informationMLS Series Liquid Level Switches. Installation and Operations Manual Section 15
MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2012-11-11 Section 15 In order to consistently bring you the highest quality full featured products, we reserve the right
More informationBasic Freeways and Multilane Highways (LOS) CIVL 4162/6162
Basic Freeways and Multilane Highways (LOS) CIVL 4162/6162 Learning Objectives Define uninterrupted facilities Determine LOS of Basic freeway segments Multilane highways Uninterrupted Flow Facilities Pure
More informationArmatures for analytical probes
Armatures for analytical probes For many different types of installations and applications Large range of probe holders General purpose, water treatment, food & beverage, pharmaceutical applications Type
More informationFiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual
Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual 27.75 23.75 25.50 20.75 Specifications: 8-13 GPM 100 strand fiber - Bubbler 75 strand fiber - Spillway Light Bar 45 ft. fiber tail
More informationContinental Industries TRANSITION FITTINGS or FAX Visit
Continental Industries TRANSITION FITTINGS 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and
More information20 to 280l/min 21MPa. econnecting a remote control valve to the vent port allows remote control of adjustment pressure.
Pressure Reducing (and heck) Valve eatures PRSSUR RU ( ) VV to 8l/min Pa -***-*- R -***-*- Specifications qthis valve is used when part of the circuit uses pressure that is lower than the main circuit.
More informationATS430 turbidity sensor Retractable insertion assembly
A MEASUREMENT & ANALYTICS INSTRUCTION ATS430 turbidity sensor Retractable insertion assembly Measurement made easy 1 Introduction This publication details installation procedures for the retractable insertion
More informationMUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.
Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read
More informationIN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4)
IN-LIN HK VLVS IT- / 3 / / (/,3/8,3/,-/) RIGHT NGL HK VLVS RT / RG-3 / / (3/8,3/,-/) Up to 5 MPa (33 PSI), 3 L/min (33 U.S.GPM) Pub. - IRTIONL ONTROLS These valves allow free flow in one direction and
More informationAutomatic Twin Greasing System
Parts Manual Automatic Twin Greasing System YOUR EFFICIENCY IS OUR CHALLENGE All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm or
More informationStand-N-Fish FULL DETAIL INSTALLATION INSTRUCTIONS
1 Stand-N-Fish FULL DETAIL INSTALLATION INSTRUCTIONS Thank you for purchasing the incredible new Stand-N-Fish Kayak Fishing System. Once installed on your kayak the Stand-N-Fish will take your kayak fishing
More informationSECTION CLIMBING WALLS. PART 1 GENERAL 1.1 SUMMARY A. This section includes the following:
SECTION 131200 - CLIMBING WALLS PART 1 GENERAL 1.1 SUMMARY A. This section includes the following: 1. GFRC Rock Realistic Climbing Wall System B. Related Sections 1. Division 04 Unit Masonry 2. Division
More informationBlue Whale Spa :- Site Preparation and Delivery
Pre-Delivery Instructions Please take the time to read this information carefully, as it will provide you with the information you will need to ensure the safe, secure, and timely installation of your
More informationTECHNICAL SUPPORT DOCUMENT 2018 CARBON MODELS 650B / 29 WARRANTY SMALL PARTS FRAME SPEC/SERVICING
2018 CARBON MODELS 650B / 29 WARRANTY SMALL PARTS FRAME SPEC/SERVICING 2018 CARBON MODELS 650B / 29 PG.i NORCO BICYCLES NEW PURCHASE CONSUMER WARRANTY PROGRAM - EFFECTIVE ON ALL 2017 MODEL YEAR BICYCLES
More informationTripod Setup Guide (M-TPx)
Items needed: 1/2 inch wrench, mast level (M-MLA), medium size wire cutters, crescent wrench, all-purpose grease, tape measure, tie wraps, redi-mix cement (optional), shovel (optional), sledge hammer (for
More informationTECHNICAL SUPPORT DOCUMENT 2018 CARBON MODELS 650B / 29 WARRANTY SMALL PARTS FRAME SPEC/SERVICING
2018 CARBON MODELS 650B / 29 WARRANTY SMALL PARTS FRAME SPEC/SERVICING 2018 CARBON MODELS 650B / 29 PG.i WARRANTY INFORMATION OWNERSHIP REGISTER YOUR BIKE The original owner must register his / her new
More informationREPORT HOLDER: FRAMECAD LICENSING LTD. POST OFFICE BOX 1292 AUCKLAND 1140 NEW ZEALAND EVALUATION SUBJECT: COLD FORMED STEEL C SHAPES AND TRACKS
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2361 Reissued 05/2017 This report is subject to renewal 05/2019. DIVISION: 05 00
More informationTD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual
Relied on Worldwide in the Most Extreme Conditions TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual Texas Electronics, Inc. Dallas, TX 75237 Fax.214.631.4218 4230 Shilling Way Tel.214-631-2490
More informationMaterials : Electro galvanized steel flanges
Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications : Absorb vibrations and noises
More informationSide-of-Pole Mount for 1 Modules (SPM1) For Module Types E, F, G, & H ASSEMBLY INSTRUCTIONS. step-by-step assembly and installation
Side-of-Pole Mount for 1 Modules (SPM1) For Module Types E, F, G, & H ASSEMBLY INSTRUCTIONS step-by-step assembly and installation Version 1, Rev A SP3348-1 PCN 022212-2 Side-of-Pole Mount for 1 Module
More informationPractical Steel Connection Software Design Using AISC 2010 Standard
Practical Steel Connection Software Design Using AISC 2010 Standard Including: Practical Advice for Reviewing Software Generated Connection Designs Steve Ashton, P.E., SECB Limit States that Changed 2
More informationAnalysis and Design of Elevated Intze Watertank and its Comparative Study in Different Wind Zones - using SAP2000
IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 2 August 2015 ISSN (online): 2349-784X Analysis and Design of Elevated Intze Watertank and its Comparative Study in Different
More information