Instructions for Use Switch Unit AGS 80 D Variant A

Size: px
Start display at page:

Download "Instructions for Use Switch Unit AGS 80 D Variant A"

Transcription

1 Instructions for Use Switch Unit AGS 80 D Variant A

2 Please note!!! The notes and technical details mentioned in this documentation / these instructions for installation reflect the status at the time of printing. Due to permanent development efforts for our products, we reserve the right to constructional modifications at any time. For this reason and depending on the state of construction and development, the illustrations of this documentation may deviate from the actual appearance of the product. But this fact does not have any influence on the functional correctness of the notes and operational sequences. Heyer Aerotech GmbH Nieverner Straße 30 D Nievern Phone: +49 (0)2603 / 2004 Fax: +49 (0)2603 / office@heyer-aerotech.de Seite 2 von 29

3 Table of Contents Page 1. Manufacturer s Data Introduction Putting into Operation Settings Functional and Operational Principles Pneumatic components Illustration AGS D Monitor Functionality General information Emergency power supply Pressure monitoring Switching Issuing alarms Logging Electrical connections Service Menu Technical Details Design Variants Warranty Technical Documentation...24 Seite 3 von 29

4 1. Manufacturer s Data Instruction for use Switch unit AGS 80 D Product: AGS 80 D Manufacturer and Sales Office Heyer Aerotech GmbH Nieverner Straße 30 D Nievern Tel.: +49 (0) / Fax.: +49 (0) / office@heyer-aerotech.de Seite 4 von 29

5 2. Introduction Dear customer! Thank you for choosing a HEYER Aerotech product. HEYER Aerotech appliances are state-of-the-art technology and manufactured according to extremely strict quality standards. You have purchased a highly professional and long-lasting product which is easy to maintain. It is based on the experience of decades and the know-how of powerful medical technology. The switch unit AGS 80 D complies with all the standards and guidelines currently applicable for the production and operation of the equipment. If, nonetheless, you should find a reason for complaint please do not hesitate to contact our customer service department at any time. Before putting the equipment into operation for the first time, please carefully read these instructions for use and pay special attention to the notes which have been marked additionally. Seite 5 von 29

6 3. Putting into Operation Instruction for use Switch unit AGS 80 D Use the patented screw joints of the curved tube on both sides of the cylinder rack to connect the gas cylinders. Tighten the screws with your hands. Please do not use any pliers, because the tightness will be achieved by the cylinder pressure. Close all the high-pressure cut-off intervalves and ventilation valves of the high-pressure manifold. Now you can open the cylinder valves to test if all the connections are tight. After that you can open the high-pressure intervalves. The pressure of the cylinder on the right and on the left is displayed on the corresponding pressure gauges. Please note!! Cylinder valves and high-pressure intervalves always have to be opened very slowly. BE CAREFUL DANGER OF EXPLOSION! When connecting oxygen please observe the applicable accident prevention regulations for oxygen. Free from oil and grease. No open light or fire. 4. Settings The reduction valves installed in the switch unit have been set at the factory. The high-pressure reduction valves ( Illustr. 2 8) have been set to appr. 12 bar. This setting is displayed on the corresponding pressure gauge. The high-pressure reduction valves ( Illustr. 2 8) are equipped with safety valves which have been set to appr. 16 bar. The constant pressure reducer ( Illustr. 2 2) has been set to 5 bar. This setting is also displayed at the corresponding pressure gauge. For the operation of the switch unit only 1 mains pressure reducer is necessary. The second redundant mains pressure reducer has to be kept closed and is only used during service works at the first mains pressure reducer. When you open the mains cut-off valves ( Illustr. 2 5) the pressure developing in the piping system will be displayed on the instruments ( Illustr. 2 6). When you open one side of the mains cut-off valves ( Illustr. 2 5) the corresponding pressure in the piping system will be displayed on the instruments ( Illustr. 2 6). 5 bar appr. 5 bar Liquid gas vaporizer min. 15 bar appr. 12 bar appr. 12 bar Seite 6 von 29

7 5. Functional and Operational Principles 5.1. Pneumatic components The HEYER AEROTECH switch unit AGS 80 D is a device which is capable of switching between a liquid gas vaporizer or two cylinder racks by means of adjustable pressure limits. The functions Reserve 1 or Reserve 2 can be assigned individually to these two cylinder racks. The device can also be operated without a liquid gas vaporizer. All the pressures displayed are monitored on the basis of their individual alarm thresholds. This is why the HEYER AEROTECH switch unit AGS 80 D is able to ensure a permanent supply of medical gas with the types of gas at its disposal. Seite 7 von 29

8 5.1.1 Illustration Illustr. 2 Switch unit AGS 80 D Model O 2 Article No.: Legend: 1 Magnetic valve 8 High pressure reducer 2 Constant pressure reducer, mains pressure ¾ 9 Sensor high pressure 3 Connection 3rd source of supply 10 Emergency supply 4 One-way valves 11 Mains connection 5 Cut-off valve ¾ 12 Relief line 6 Sensor mains pressure 13 Sensor medium pressure / system pressure 7 Safety valve 6 bar Seite 8 von 29

9 5.2. AGS D Monitor Functionality General information The control unit AGS-D is used for automatic switching in a gas switching unit for medical gas supply. The mains pressure is kept by automatic switching between a main source and two auxiliary sources. The control unit makes sure that the corresponding gas is permanently supplied. Pressures of the main source and of the auxiliary sources as well as system and mains pressures are constantly monitored. Channel control is carried out by pressure transmitters (4-20mA). Each pressure has been assigned to a (multi-coloured) LED. These LEDs either show the normal condition (green) or a state of alarm (yellow or red for mains pressure). The QUIT key allows the user to suppress the acoustic alarm. With an alarm of the mains pressure, the acoustic signal is repeated after 12 minutes. The LCD displays the sources, the alarm thresholds and the current pressure. In addition, the sequence of sources, which is relevant for switching, is displayed in Roman numerals. The currently active source is shown by inverting the source designation. In the lower area, the state of the corresponding pressure is displayed in text form (i.e. OK, HIGH, LOW). Seite 9 von 29

10 The following 5 keys are on the user interface: a) ON/OFF key b) QUIT key c) UP and DOWN keys d) ENTER key Pressing the ON/OFF key for some time will turn the unit on or off. The QUIT key can be used to suppress the acoustic signal. For navigating in the service menu use the UP and DOWN keys and the ENTER key. On the user interface there are 3 additional LEDs (Battery, Controller, Info). The LED for Battery is green when the state of the batteries is ok. The Battery LED is red when the battery is faulty or when it has not been connected. The LED for Controller is green when the micro-controller system has not found any failures during its regular self-test, otherwise it is red. The LED for Info flashes green when the cache contains messages Emergency power supply When the main power supply via transformer unit fails one battery will backup the power supply of the control unit. The electronic elements will stay in operation for appr. 2 more hours. During this time the backlights of the LCDs will be turned off. At the push of a button, the backlights will be activated for 15 seconds. The switching valves and the signal relays will be turned off as well Pressure monitoring The channels in use are monitored on the basis of an upper and a lower alarm threshold. In case of an error, the corresponding LED will shine red or yellow and the status in the LCD will flash. In addition, an acoustic alarm will be activated. When pressing the QUIT key, the acoustic alarm will be suppressed and both the source and the LED will flash. With an alarm of the mains pressure, the suppression will be overridden after 12 minutes. Pressure monitoring of the sources left and right has a hysteresis of 2bar at the lower alarm threshold. That means, pressure must exceed the lower alarm threshold by 2bar upwards before pressure for the control unit is accepted as OK by the system. Seite 10 von 29

11 Switching When the pressure of the liquid gas vaporizer falls below a preset threshold value, the system will switch to the cylinder rack defined as Source II. When the corresponding switching pressure falls below the acceptable value the system will also switch. When the pressure of Source II lies below its also adjustable threshold value, the system will immediately change to the cylinder rack Source III. In case that the cylinder rack Source II falls below its threshold value, the control unit will also switch to Source III. As soon as the pressure of the liquid gas vaporizer has reached a level above its threshold value, the cylinder racks will be deactivated again Issuing alarms Issuing alarms for failure states is carried out by means of potential-free signal contacts. For that purpose, 5 alarm contacts and a common contact are available Logging The control unit has been equipped with a cache for a maximum of 250 entries and a history memory for a maximum of 1,000 entries. Any important failures or messages will be recorded in the cache. After acknowledging them in the service menu, they will be transferred to the history memory. Seite 11 von 29

12 5.3 Electrical connections On the rear side of the control unit you will find the following connections: Identifier Trafoeinheit/ Transformer unit Ventil 1 / Valve 1 Ventil 2 / Valve 2 Floweinheit / Flow unit USB CAN-Bus S1 S2 S3 S4 S5 Alarm contacts Vorw.-relais /Preheating relay Description Connection to the transformer unit Magnetic valve for cylinder rack left Magnetic valve for cylinder rack right Connection to flow unit Connection to PC Connection to net Pressure sensor mains pressure Pressure sensor medium pressure Pressure sensor liquid gas vaporizer Pressure sensor cylinder rack right Pressure sensor cylinder rack left D-Sub 25-pole socket signal contacts Connection for pre-heating unit Table 1: Connections of control unit Colour Brown Blue Description 1: +U B 2: -U B Out 4-20mA Table 2: Terminal assignment sensor cable Seite 12 von 29

13 Contact Description 1 G: Common contact 2 A: Common contact 3 R: Alarm contact 1 4 G: Alarm contact 2 5 A: Alarm contact 2 6 R: Alarm contact 3 7 G: Alarm contact 4 8 A: Alarm contact 4 9 R: Alarm contact R: Common contact 15 G: Alarm contact 1 16 A: Alarm contact 1 17 R: Alarm contact 2 18 G: Alarm contact 3 19 A: Alarm contact 3 20 R: Alarm contact 4 21 G: Alarm contact 5 22 A: Alarm contact Table 3:Contact assignment D-Sub 25-pole socket Seite 13 von 29

14 Explanation: For each alarm contact there is a relay with an operating and a rest contact. G: common contact A: operating contact R: rest contact When G is connected through to R, this means that an error has come up or that the equipment has been switched off. When G is connected through to A, this means that there is no error, i.e. the channel is OK. 5.4 Service Menu The service menu is started by pressing the ENTER key. When no key has been activated in the service menu for 1 minute it will be closed automatically. The service menu is set up as follows: 1 Current messages 2 Old messages 3 I: Cyl. left II: Cyl. right 4 Info 5 Alarm thresholds 6 Service 7 EXIT By using the UP and DOWN keys, the entry required can be selected (inverse presentation). By pressing the ENTER key you can change to the corresponding sub-menu. You can leave the main menu by selecting 7 EXIT and pressing the ENTER key. You can also leave the main menu by pressing the QUIT key. Seite 14 von 29

15 To 1) The sub-menu aktuelle Meldungen/current messages allows you to view the cache. Use the UP and DOWN keys to browse the cache which includes up to 250 messages. The first message will be at the top of the memory. In order to delete the current messages the arrow has to be placed on the first message. Then use the ENTER key to select the entry (inverse). By pressing the QUIT key, the entry will be transferred from the cache to the history memory. To 2) The sub-menu alte Meldungen/old messages allows you to view the history memory. The history memory is made up of a maximum of 1,000 messages. When exceeding this limit, the oldest message will be deleted. The last entry, chronologically seen, is at the top of the list. Use the UP and DOWN keys to view the history memory. To 3) In II: Fl. Links III: Fl. Rechts/II: Cyl. left III: Cyl. right you can change the order of sources by pressing the ENTER key. Seite 15 von 29

16 To 4) The sub-menu Info allows you to view the following system information: System time Next service month Serial number Software versions To 5) The upper and lower alarm thresholds for Flasche Links/cylinder left, Flasche Rechts/cylinder right, Kaltvergaser/liquid gas vaporizer, Mitteldruck/medium pressure and Netzdruck/mains pressure can be changed in this sub-menu. Use the UP and DOWN keys to select the value to be changed. The entry is displayed in inverse form when you use the ENTER key and can then be changed by means of the UP and DOWN keys. Pressing the ENTER key again will inactivate the inversion and save the value. Use EXIT to leave the sub-menu. Pressure sensor Lower threshold Upper threshold Steps bar bar bar 5 bar 0 20 bar 5 20 bar 5 20 bar 1 bar 0 12,5 bar 3 6 bar 3 6 bar 0,1 bar Table 4: Ranges for setting thresholds To 6) Sub-menu Service This menu item is used to determine and carry out the basic settings and customer-specific parameters of the control system. In order to guarantee trouble-free operation only expert service personnel has access to this menu item. Seite 16 von 29

17 The following values are set at the factory: Designation Upper alarm threshold source left Lower alarm threshold source left Upper alarm threshold source right Lower alarm threshold source right Upper threshold liquid gas vaporizer Lower alarm threshold liquid gas vaporizer Upper alarm threshold medium pressure Lower alarm threshold medium pressure Upper alarm threshold mains pressure Lower alarm threshold mains pressure Order of sources Source II Liquid gas vaporizer available Pre-heater available Number of short events within 1 hour 5 Switch pressure liquid gas vaporizer pressure Cold R1 Switch pressure medium pressure Cold R1 Switch pressure medium pressure R1 R2 Switch delay Cold R1 Switch delay R1 R2 Alarm delay cylinder rack left Alarm delay cylinder rack right Alarm delay liquid gas vaporizer Alarm delay medium pressure Alarm delay mains pressure Alarm delay liquid gas vaporizer medium pressure Service interval Standard value 220 bar (250 bar sensor) 50 bar (250 bar sensor) 220 bar (250 bar sensor) 50 bar (250 bar sensor) 18 bar (20 bar sensor) 9 bar (20 bar sensor) 18 bar (20 bar sensor) 9 bar (20 bar sensor) 5,5 bar (12,5 bar sensor) 4,5 bar (12,5 bar sensor) Cylinder rack left Yes No 9 bar 9 bar 9 bar 0.5 sec 0.5 sec 2 sec 2 sec 2 sec 2 sec 2 sec 2 sec 6 months Service month Service phone number Rest cache 50 Common contact message with service Common contact message with overflowing cache Common contact message with too many temporary events LCD contrast 32 Table 5: Factory settings Yes Yes Yes Seite 17 von 29

18 Purpose and characteristics Monitoring pressures of supply source (negative pressure) for medical gas supplies and monitoring mains pressure (excess and negative pressure), displaying cylinder rack ready for operation and signalling status Monitoring 5 pressures simultaneously. Red, orange (state of alarm) and green (pressure OK) LEDs Display of cylinder rack ready for operation Acoustic alarm with buzzer Suppressing acoustic alarm by means of button Signalling state by potential-free changeover contact per channel Electrical connections 2 contacts for connection of 24V supply, DC voltage or AC voltage (50Hz). Connections for Channel 1 / 2 / 4 (for designation of channels see Illustr. 3): 2 contacts for press key Pressure alarm low (opens in a state of alarm) 3 contacts for remote control Connections for Channel 3 (for designation of channels see Illustr. 3): 3 contacts for switch Operating status display Connections for Channel 5 (for designation of channels see Illustr. 3): 2 contacts for press key Pressure alarm low (opens in a state of alarm) 2 contacts for press key Pressure alarm high (opens in a state of alarm) 3 contacts for remote control For press keys, please only use potential-free switches. When a press key is not used its connections have to be short-circuited. Seite 18 von 29

19 7. Technical Details Electrical Details Operating voltage: Connecting power: 230 V, 50 Hz 50 VA Pneumatic Details Max. cylinder pressure: Operating pressure: Input pressure liquid gas vaporizer Max. flow rate: Potential-free contacts: 250 bar 9 to 12 bar min. 15 bar 80 to 120 Nm 3 /h, depending on design 5 pcs. Components Cut-off valve Pressure sensors Safety valve One-way valve Constant pressure reducer Magnetic valves High-pressure reducer Seite 19 von 29

20 8 Design Variants AGS 80 D - with two constant pressure reducers incl. connection of 3rd source of supply Gas type Article no.: O Air N2O CO Please indicate flow rate Seite 20 von 29

21 9. List of Spare Parts Instruction for use Switch unit AGS 80 D Item Article number Designation of article Sealing, connecting curved tube, oxygen, 18 x 10 x 4, Sealing, connecting curved tube non-inflammable gases, 16 x 8 x Sealing, connecting curved tube CO2 16 x 8 x Sealing, connecting curved tube, laughing gas 12.5 x 7 x Cu-sealing 19 x 13 x Cu-sealing 23 x 13 x Cut-off valve DN 20 ( R 3/4 ) with butterfly handle with butterfly handle Constant pressure reducer Pressure transmitter 0-12,5 bar Pressure transmitter bar Pressure transmitter 0-20 bar Safety valve ( R ½ ; R ¾ ) AGS D control unit Seite 21 von 29

22 Item Article number AGS D Mains adapter AGS D Cable set 16 left High pressure reducer right Magnetic valve ¾ One-way valve AGS Set of spare parts / repair set, high-pressure reducer MS AGS Wearing part - set constant pressure reducer ¾ 0 to 16 bar Seite 22 von 29

23 10. Warranty The warranty period for the HEYER AEROTECH Switch Unit AGS 80 D is 12 months starting from the date of sale in accordance with the following conditions: During the period of warranty, we will eliminate, free of charge, any damage or failures of the equipment caused by verifiable faults in production or in the material, provided that these failures have been reported without delay after detection. Deviating from this, the warranty for engines of any type, compressors, electric switching devices, semiconductor elements, electric displays and measuring equipment is six months. The elimination of faults, free of charge, will be carried out in our factory. This warranty is not applicable to fragile parts made of glass, for example, or consumable and wearing parts. In the case of a guarantee, the decision of whether to repair or exchange the equipment will be at our own option. Cases of guarantee will neither extend the period of warranty nor will they represent the start of a new period of warranty. Spare parts which are installed will not be subject to an individual period of warranty. Any damage caused by improper use, faulty operation, mechanical damage or nonobservance of the instructions for use as well as any damage caused by force majeure or any other unusual environmental conditions will not be covered by the warranty. The warranty claim will expire when interventions, changes or repairs of the equipment have been carried out by people who have not been authorised by us to do so or when the equipment has been used with additional accessories or spare parts of strange origin. Further claims as well as any so-called consequential damage will be excluded as long as liability is not required by law. Equipment may be subject to technical changes without notice! Rev. 2.2 as per 01 June 2010 Seite 23 von 29

24 11. Technical Documentation High pressure reducer Seite 24 von 29

25 Pos. Benennung / Description Menge / Quantity Included in repair set Item Dèsignation / Descrizione Débit / Quantità 4 O-Ring (23,3x2,4) / O ring / O anneau / Quarnizione O-Ring 1 X 5 Verschlußschraube, kpl. / Locking screw, compl. / Vis de fermeture, compl. / Tappo, compl. 1 X 6 Druckteller / Pressure plate / Plaque de pression / Piatto a pressione 1 X 7 Bremse / Brake / Frein / Freno 1 X 8 Feder / Spring / Ressort / Molla 1 X 9 Dichtung / Sealing / Joint / Quarnizione 2 X 10 Federteller / Spring plate / Disque de ressort / Piatto molla 1 X 11 Ventilsitz / Valve seat / Siège de soupape / Sede della valvola 1 13 Ventilkegel / Valve cone / Cône de soupape / Otturatore 1 X 14 Schraube / Screw / Vis / Vite 1 X 15 O-Ring (75x3) / O ring / O anneau / Quarnizione O-Ring 1 X 16 Gleitring / Slide ring / Anneau de glissement / Scivolo anello 1 X 18 Membrane / Diaphragm / Membrane / Membrana 1 X Membranplatte / Diaphragm plate / Plaque de membrane / Piatto di membrana Gehäuse Abblaseventil / Housing for pressure relief valve / Cage pour la soupape de surète / Corpo valvola di sfiato Ventilkegel, kompl. / Valve cone, compl. / Cône de soupape, compl. / Otturatore, compl. 1 X 1 X 1 X Manometer P 1 2 Pressure gauge P 1 Manomètre P 1 1 Manometro P 1 Manometer P 2 3 Pressure gauge P 2 Manomètre P 2 1 Manometro P 2 23 Einlegemutter / Insertion screw / Ecrou à inserer / Dado insertito 1 24 Einstellschraube / Adjusting screw / Vis de réglage / vite del regolamento 1 25 Mutter / Nut / Ecrou / Dado 1 26 Mutter / Nut / Ecrou / Dado 1 27 Zylinderstift / Cylindrical pin / Pied de centrage / Perno cilindrato 1 O 2 = Sauerstoff / oxygen / oxygene / ossigeno P 1 = max. Vordruck (bar) / max. inlet pressure (bar) / max. pression amont (bar) / mas. pressione d ingresso (bar) P 2 = max. Hinterdruck (bar) / max. outlet pressure (bar) / max. pression aval (bar) / mas. pressione di uscita (bar) Seite 25 von 29

26 Seite 26 von 29

27 Seite 27 von 29

28 Magnetic valve Nominal width DN 20 mm Case material Brass acc. to DIN EN Isolation class sealing material EPDM H Valve, interior parts Sealing material Stainless steel, brass EPDM Medium temperature EPDM -40 to +120 C Ambient temperature max. +55 C Voltage tolerance ±10 % Rated service type Continuous service 100% ED Electrical connection Plug tags acc. to DIN EN Form A (formerly DIN 43650) for outlet Type 2508 Protection type Position of installation Switching times IP 65 with outlet At will seconds (depending on nominal width and differential pressure) Seite 28 von 29

29 Seite 29 von 29

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO

Instructions for Use. Plug connection for medical gas and vacuum acc. to DIN / 2004 DIN EN ISO Instructions for Use Plug connection for medical gas and vacuum acc. to DIN 13260-2 / 2004 DIN EN ISO 9170-1 Table of Contents Page 1. MANUFACTURER S DATA... 3 2. INTRODUCTION... 4 3. APPLICATION... 5

More information

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max

Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max Instructions for use Evacuation system compressed air injector SL 20 / SL 20 Max SL 30 / SL 30 Max Table of Contents Introduction 1. Description of Functions 2. Putting into Operation 3. Instructions for

More information

Instructions for use Compressed air injector with water trap

Instructions for use Compressed air injector with water trap Instructions for use Compressed air injector with water trap Table of Contents Introduction 1. Description of Functions 2. Putting into Operation 3. Instructions for Cleaning and Care 3.1 Disassembling

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

Instruction Manual Dräger MSI P7 and MSI P7 plus

Instruction Manual Dräger MSI P7 and MSI P7 plus Dräger MSI GmbH Rohrstraße 32 58093 Hagen Tel.: +49-2331 / 9584-0 Fax: +49-2331 / 9584-29 e-mail: info@draeger-msi.de D 923; Edition 2011-01-01 Content 1. General Hints Page 4 2. The Instrument 2.1 Front

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Safety Manual VEGAVIB series 60

Safety Manual VEGAVIB series 60 Safety Manual VEGAVIB series 60 NAMUR Document ID: 32005 Contents Contents 1 Functional safety... 3 1.1 General information... 3 1.2 Planning... 4 1.3 Adjustment instructions... 6 1.4 Setup... 6 1.5 Reaction

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTRUCTION MANUAL Pressure Relief Device LPT INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1*

Safety Manual. Process pressure transmitter IPT-1* 4 20 ma/hart. Process pressure transmitter IPT-1* Safety Manual Process pressure transmitter IPT-1* 4 20 ma/hart Process pressure transmitter IPT-1* Contents Contents 1 Functional safety 1.1 General information... 3 1.2 Planning... 4 1.3 Instrument parameter

More information

Safety Manual VEGAVIB series 60

Safety Manual VEGAVIB series 60 Safety Manual VEGAVIB series 60 Contactless electronic switch Document ID: 32002 Contents Contents 1 Functional safety... 3 1.1 General information... 3 1.2 Planning... 4 1.3 Adjustment instructions...

More information

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication

More information

Pressure relief valve DHV 716 set range: 0,5-10,0 bar

Pressure relief valve DHV 716 set range: 0,5-10,0 bar Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of

More information

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application: MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Technical Data Sheet MF010-O-LC

Technical Data Sheet MF010-O-LC Technical Data Sheet MF010-O-LC - 1 - 1. Properties The oxygen measuring system MF010-O-LC determines the oxygen content in gas mixtures up to a temperature of 250 C. It is particularly suitable for the

More information

better measurement Simply a question of

better measurement Simply a question of Simply a question of better measurement SCHMIDT Flow Sensor SS 20.600 The powerful industrial professional for demanding applications involving air and gases. Industrial processes Pneumatic technology

More information

Flow controller Type ED/CCB311 Instruction manual

Flow controller Type ED/CCB311 Instruction manual Flow measurement Flow controller Type ED/CCB311 1. GENERAL DESCRIPTION page 4 2. DETAILED DESCRIPTION page 4 3. PIPE - EXPLOITATION page 5 4. PREVENTIVE MAINTENANCE page 5 5. REPLACEMENT OF THE CONTACT

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

User Manual. Quantos Automated Dosing Liquid Module

User Manual. Quantos Automated Dosing Liquid Module User Manual Liquid Module 1 Safety Information 1.1 Definition of warnings and symbols Signal Words WARNING for a hazardous situation with medium risk, possibly resulting in severe injuries or death if

More information

Inoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.

Inoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development. Inoxair Repair Manual Edition: 12/2010 Content 1) Serial number 2) Technical data 3) Functional principle 4) Problem analysis 5) Removal 6) Repairs 7) Circuit diagram and cable-connection-plan 8) Pneumatic

More information

Supplementary Operator s Manual 42/24-14 EN Rev. 3

Supplementary Operator s Manual 42/24-14 EN Rev. 3 Advance Optima Continuous Gas Analyzers AO2000 Series with Uras26, Magnos206, Caldos25, Caldos27 Designed per Category 3G for Measurement of Flammable Gases ( Safety Concept ) and Non-flammable Gases Supplementary

More information

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument

OxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument OxyScan Graphic Operating Instructions UMS Micro-oxygen sensor 501 Microprocessor instrument Introduction Thank you for choosing the UMS Micro Oxygen Sensor 501 - a highly advanced product! Please read

More information

2/2-Way Proportional Valve (motor-driven)

2/2-Way Proportional Valve (motor-driven) 2/2-Way Proportional Valve (motor-driven) Type 3280 can be combined with Seat valve with stepper motor - actuator isolated from flow path Excellent range (1:100) Low power consumption Fast response Orifice

More information

ECL Comfort 110, application 131 (valid as of software version 2.00)

ECL Comfort 110, application 131 (valid as of software version 2.00) Operating Guide ECL Comfort 110, application 131 (valid as of software version 2.00) English version www.danfoss.com How to navigate? Adjust temperatures and values. Switch between menu lines. Select /

More information

Pressure relief valve DHV 725 set range: 0,2-10,0 bar

Pressure relief valve DHV 725 set range: 0,2-10,0 bar Pressure relief valve DHV 75 set range: 0, - 0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level

More information

Mass Flow Meter (MFM) for Gases

Mass Flow Meter (MFM) for Gases 873 Mass Flow Meter (MFM) for Gases Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy Short response time Compact design and digital

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar

Pressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at

More information

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar

Pressure Reducing Valve DMV 755 set range: 1,0-9,0 bar Pressure Reducing Valve DMV 755 set range:,0-9,0 bar Advantage pressure setting possible at any time, also during operation high reproducibility of the set pressure high level of operating safety and long

More information

Control units. Installation and operating instructions Series: DP-Control

Control units. Installation and operating instructions Series: DP-Control Control units Installation and operating instructions Series: DP-Control Table of Contents 1 Manual introduction 1.1 Preface... 4 1.2 Icons and symbols... 4 2 Identification, service and technical support

More information

Pressure Switches Application Guideline

Pressure Switches Application Guideline Pressure Switches Application Guideline Product Overview The Fema Pressure Switch product portfolio provides devices suitable for many applications. The portfolio contains Special functions and equipment

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet

Automatic Control Unit. Cervomatic EDP.2. Type Series Booklet Automatic Control Unit Cervomatic EDP.2 Type Series Booklet Legal information/copyright Type Series Booklet Cervomatic EDP.2 All rights reserved. The contents provided herein must neither be distributed,

More information

Budget Range Operators Handbook

Budget Range Operators Handbook Budget Range Operators Handbook BAMBI AIR COMPRESSORS LTD 152 Thimble Mill Lane Heartlands Birmingham B7 5HT United Kingdom Tel: 0121 322 2299 Fax: 0121 322 2297 Email: sales@bambi-air.co.uk www.bambi-air.co.uk

More information

Pressure Reducing Valve DMV 750

Pressure Reducing Valve DMV 750 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 D-32602 Vlotho Fon +49 (0) 57 33-7 99-0 Fax +49 (0) 57 33-7 99-2 00 www.asv-stuebbe.de contact@asv-stuebbe.de Pressure Reducing Valve DMV 750 Advantages reduction

More information

KERN EG/EW Version /02

KERN EG/EW Version /02 E KERN EG/EW Version 1.5 07/02 Operating Instructions Electronic Precision Balances Contents 1 TECHNICAL DATA... 20 2 UNPACKING AND STANDARD ACCESSORIES... 23 3 SETTING UP THE BALANCE... 23 4 EXTERNAL

More information

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use Pressure regulator made of brass Operating Manual 1. Intended Use Line or outlet pressure regulators- /reducer for Air, gases and liquids which is designed to effect reduction to a downstream pressure

More information

AUTOMATIC GAS MANIFOLDS

AUTOMATIC GAS MANIFOLDS AUTOMATIC GAS MANIFOLDS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com

More information

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies We reserve the right to make technical changes without notice. Technische Änderungen vorbehalten. Sous réserve de modifications techniques.

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2

KGW - ISOTHERM. Operating Instructions. Level controlling device for liquid nitrogen LEVEL CONTROL LN2 KGW - ISOTHERM Germany 76185 Karlsruhe Gablonzer Straße 6 Tel. 0049 / 721 / 95897-0 Fax. 0049 / 721 / 95897-77 email:info@kgw-isotherm.de Internet: www.kgw-isotherm.de Operating Instructions Level controlling

More information

CCT-7320/ROC-2313 Reverse Osmosis Controller

CCT-7320/ROC-2313 Reverse Osmosis Controller CCT-7320/ROC-2313 Reverse Osmosis Controller 1 General The instrument is a combined control instrument of a reverse osmosis controller and an on-line conductivity instrument. It can perform the operation

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide GRUNDFOS alldos product information Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide Construction and function Modular system Vacuum regulator for direct mounting

More information

Installation and Operating Instructions Bypass Flow Meter DST

Installation and Operating Instructions Bypass Flow Meter DST Installation and Operating Instructions Bypass Flow Meter DST DST_gb_A4_1.0.doc Version 1.0 1 von 10 Contents 1. Foreword... 3 2. Safety... 3 2.1. Symbol and meaning... 3 2.2. General safety directions

More information

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version 2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for

More information

SonoSelect 10 and SonoSafe 10 energy meters

SonoSelect 10 and SonoSafe 10 energy meters SonoSelect 10 and SonoSafe 10 energy meters Description The Danfoss SonoSelect 10 and SonoSafe 10 are ultrasonic compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

DK46 - DK800 Supplementary instructions

DK46 - DK800 Supplementary instructions DK46 - DK800 Supplementary instructions Variable area flowmeter Device category II2G with electrical internals Additional Ex manual KROHNE CONTENTS DK46 - DK800 1 Safety instructions 3 1.1 General... 3

More information

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model

User's Manual. Heavy Duty Dissolved Oxygen Meter. Model User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

Mass Flow Controller (MFC) for Gases

Mass Flow Controller (MFC) for Gases Mass Flow Controller (MFC) for Gases Direct flow measurement with CMOSens technology for nominal flow rates from 0 ml N to 0 l N High accuracy and reproducibility Ingress protection IP Type can be combined

More information

Pressure Automated Calibration Equipment

Pressure Automated Calibration Equipment GE Measurement & control Pressure Automated Calibration Equipment Safety Instructions and User Guide - K0447 PACE5000 PACE6000 K0447 Issue No. 9 1 10 1 PACE5000 1 2 3 4 5 PACE6000 2 6 7 8 3 4 5 6 7 8 9

More information

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical

More information

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Contact Pressure Vacuum Gauge MS10 Instruction Manual Contact Pressure Vacuum Gauge Table of Contents 1. Safety Instructions 2. Intended Applications 3. Product Description and Functions 4. Installation 5. Commissioning 6. Maintenance

More information

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42

More information

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering

More information

Pressure Reducing Valve DMV 750 set range: bar

Pressure Reducing Valve DMV 750 set range: bar Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long

More information

Pressure Relief Valve DHV 718

Pressure Relief Valve DHV 718 Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media

More information

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22. *09005087* DB_BA_EN_ME01_S Rev.A 12/16 *09005087* d e v e l o p i n g s o l u t i o n s Data Sheet and Operating Manual ME01 Digital manometer Table of Contents ME01 ## # 87 # HL S#### Dust explosion protection

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

The Univentor 1250 Anaesthesia Unit

The Univentor 1250 Anaesthesia Unit THE UNIVENTOR 1200/1250 ANAESTHESIA UNIT The Univentor 1250 Anaesthesia Unit TABLE OF CONTENTS EDITION 1 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2

More information

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar Instruction manual for high purity gas pigtails 200 bar / 300 bar Contents Contents... 2 1. Preface... 3 1.1 Overview... 3 1.2 General... 3 1.3 Intended use... 4 1.4 Personnel requirements... 4 2. For

More information

Test and Adjustment Instructions Compressed Air Processing System Air Processing Unit (APU)

Test and Adjustment Instructions Compressed Air Processing System Air Processing Unit (APU) Test and Adjustment Instructions Compressed Air Processing System Air Processing Unit () 1st issue 8150004983 815 000 498 3 This document is not covered by a revision service. New versions can be found

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25

Flow VA 520. incl. temperature measurement. Intelligent solutions for ac- for compressed air and gases R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 VA 520 incl. temperature R 1/4 (DN 8) DN 15 R 3/4 (DN 20) DN 25 R 1 1/4 (DN 32) DN 40 R 2 (DN 50) Intelligent solutions for ac- for compressed air and gases work according to the approved calorimetric

More information

Pressure relief valve

Pressure relief valve Pressure relief valve Operating manual Series DHV 718 Version BA-2016.01.11 EN Print-No. 300 524 TR MA DE Rev001 ASV Stübbe GmbH & Co. KG Hollwieser Straße 5 32602 Vlotho Germany Phone: +49 (0) 5733-799-0

More information

Service Test Unit for ROSS Proportional Valves RESK

Service Test Unit for ROSS Proportional Valves RESK Service Unit for Proportional Valves Page 1 Technical Description ROSS 04.08.2015 Service Test Unit for ROSS Proportional Valves Technical Description V 1.0 / 2015 RESK 4591.40 For all Prop Valve Models

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual Content Page For your Safety 3 General Description 3 Detection Principle 4 Operational Notes 4 Design 4 Mounting Position of CS21 5 Mounting 6 Installation of Electrical

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL CPX EMERGENCY STANDBY MANIFOLD INSTALLATION, OPERATIONS & MAINTENANCE MANUAL Company Registered Office: Crown House, Stockport, Cheshire, SK13RB No. 850 0700 67 Registered in England and Wales No. 05058855

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT 200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

HBLT-A1 LIQUID LEVEL SENSOR

HBLT-A1 LIQUID LEVEL SENSOR Instruction manual HBLT-A1 LIQUID LEVEL SENSOR for measuring liquid level in refrigerant vessels Instruction manual HBLT - A1 - Liquid level Transmitter (HBLT-A1-008-UK) 1 / 16 Contents Safety instructions...

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

Met One E-BAM Particulate Monitor

Met One E-BAM Particulate Monitor STANDARD OPERATING PROCEDURES Met One E-BAM Particulate Monitor AMBIENT AIR MONITORING PROGRAM for the 130 LIBERTY STREET DECONSTRUCTION PROJECT LOWER MANHATTAN DEVELOPMENT CORPORATION 1 Liberty Plaza

More information

Pressure switch Type BCP

Pressure switch Type BCP Data sheet Pressure switch Type BCP The BCP type is a series of dedicated switches for safety and monitoring of steam and hot water boilers. The BCP incorporates a single-pole changeover microswitch where

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA

Maintenance Manual. Liquid Level Transmitter CT801-SI, CT801-TA CT801-SI, CT801-TA Maintenance Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Maintenance Manual CT801-SI, CT801-TA

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

High Pressure Breathing Air Compressors

High Pressure Breathing Air Compressors High Pressure Breathing Air Compressors [ Full variety for different applications] MSA offers a comprehensive range of high pressure breathing air compressors for both the firefighting and diving market,

More information

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs

Operating Procedures for GripTight 15.5 SDR & IPS Test Plugs EST Group DC2518 08/01 REV 3 12/12 Page 1 of 6 Operating Procedures for GripTight SDR & IPS Test Plugs WARNING For proper operation, GripTight plugs must be assembled as shown in Figure 1. Pressure testing

More information

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0 High Accuracy Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

Flamco Flamco-Fill STA Flamco-Fill STM

Flamco Flamco-Fill STA Flamco-Fill STM STA STM Typ STA 5936 Typ STM 5937 GB Installation and operating instructions 1999, 2 Contents GB UK Limited P.O. Box 9, Washway Lane, St. Helens, Merseyside WA10 6FE United Kingdom Telephone: 01744 744744

More information

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2 Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting

More information

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is

More information