York Peel Feeder Main Condition Assessment Project Review & Results Presentation
|
|
- Sylvia Atkinson
- 6 years ago
- Views:
Transcription
1 York Peel Feeder Main Condition Assessment Project Review & Results Presentation May 28, 2014 Junjie Tu (Thomas) P.Eng. Infrastructure Engineer, Strategy & Business Planning, Environmental Services Department The Regional Municipality of York Ramzi Khalaf MBA, P.Eng., PMP Program Manager Pure Technologies Ltd.
2 Table of Contents Project Background Feeder Main Overview Project Scope & Inspection Details Scope SmartBall Leak Detection PipeDiver EM Inspection Transient Pressure Monitoring Engineering Services Results SmartBall Leak Detection PipeDiver EM Inspection Transient Pressure Monitoring Engineering Services
3 York Region Water System Upper Tier Municipality Serving Nine Lower Tier Municipalities: Markham, Vaughan, Richmond Hill, Aurora, Whitchurch Stouffville, King, East Gwillimbury, Georgina and Newmarket - Population: Approx. 1.1 Million Water Infrastructure: Watermain: 330 km Surface WTP: 2 Pumping Stations: 20 Elevated Tank: 29 Reservoir: 15 Groundwater Wells: 40
4 Project Background Feeder Main Overview Airport Road Pumping Station in Peel Region to Maple Reservoir in York Region, ~25 KM, built in mm PCCP, two Manufacturers: Hyperscon now Hanson & Munro Managed and operated by Peel Region (OCWA) and York Region Critical fresh water supply asset for York Region: 21% (165 MLD) in 2013; 32% (331 MLD) in 2031 One surfacing leak in 2009, 135m main diversion upstream from East Humber River
5 Project Background Feeder Main Overview Contd.
6 Project Scope Untethered Live Leak Detection Using SmartBall Technology Untethered Live Electromagnetic (EM) Inspection Using PipeDiver Technology Engineering Condition Assessment, Risk Assessment and Recommendations
7 Planning Deliverables Project Scope
8 Inspection Details SmartBall Inspection: Launch
9 Inspection Details SmartBall Inspection: Extraction
10 Inspection Details PipeDiver Inspection: Launch
11 Inspection Details PipeDiver Inspection: Tracking (SmartBall & PipeDiver) 27 Tracking Sites 2 Hydrophone tracking sites (Special ARV location)
12 Inspection Details PipeDiver Inspection: Extraction
13 Inspection Details Transient Pressure Monitoring Chamber Y8: Proximity to Lowest Point on Main Chamber Y20: Proximity to Highest Point on Main Chambers Accessible without Need for Traffic Control
14 Project Scope Engineering Services Consequence of Failure (COF) Score Finite Element Analysis (Curves) Likelihood of Failure (LOF) Score Risk Score (COF * LOF) Recommendations
15 Results: SmartBall Leak Detection Survey Duration: 19:20 Average Velocity: m/s Leak Anomalies: 7 Gas Pockets: none Summary of Leaks and Field Investigation Results Leak # Location Estimated Size Investigation and Field Verification Results 1 Chamber CH2 Medium Drain valve left open during SmartBall inspection, addressed by OCWA 2 Chamber Y8 Small Leak noise most likely generated by PRV connected to Y8 via 750mm lateral 3 Chamber Y9 Medium Leaking drain valve picked up by SmartBall, York Region closed it after field investigation 4 477m DS of VC2; 169.1m US from VC3 Medium 5 VC3 Medium m Downstream of VC3 Chamber 23m Upstream from 65 degree bend US from Maple PS Medium Ground microphone did not pick up the leak from above ground Leaking flange used to insert tool tracking hydrophone, uninstalled after inspection Ground microphone did not pick up the leak from above ground Recommended Action None None None To Be Addressed None To Be Addressed Small Surfacing leak located around the area To Be Addressed
16 Results: SmartBall Leak Detection Leak 4: 169m US from VC3, under roadway (Rutherford Road) Leak 5: Leaking flange used for SBR insertion into water column Leak 6: 25m DS from VC3, under roadway (Rutherford Road)
17 Results: SmartBall Leak Detection Field Verification Excavation/Repair* *: Adjacent parallel 1200mm line, same axial location Leak 7: 23m US from 65 Degree Bend near Maple PS, surfacing leak
18 Results: PipeDiver EM Inspection Distress
19 Results: PipeDiver EM Inspection Rank Pure Ref No. Piece No. STA Pipe Length (m) Break Position (m) # WB by Region Total #WB Distressed Pipes in Regional Municipality of Peel 1 50 N/A * C-E * 3 84 N/A C-E N/A Distressed Pipes in Regional Municipality of York N/A * N/A N/A N/A N/A N/A N/A W-E N/A N/A
20 Results: PipeDiver EM Inspection Wire Breaks (WB) <25
21 Results: PipeDiver EM Inspection 25<WB<50 (Orange); WB>50 (Red)
22 Results: Transient Pressure Monitoring (Y20)
23 Results: Transient Pressure Monitoring (Y20) Table 2.7: Summary of Transient Pressure Data Chamber Y-20 Number of Monitored Pressure Events Greater than 8 psi 16 Number of Monitored Pressure Events Greater than 10 psi 4 Average Monitored Maximum Pressure, psi 3.95 Median Monitored Maximum Pressure, psi 4.08 Minimum Recorded Pressure, psi Date and Time of Minimum Recorded Pressure May 27, :00 AM Maximum Recorded Pressure, psi Date and Time of Maximum Recorded Pressure May 27, :00 AM Number of Monitored Pressure Events with a Difference Greater than 10 psi (Maximum minus Minimum Pressure) 1 Greatest Difference Between Minimum and Maximum Recorded Pressure, psi Minimum Pressure at Greatest Difference, psi Maximum Pressure at Greatest Difference, psi Date and Time of Greatest Difference May 27, :00 AM
24 Segment Start End Results: Engineering Services COF Consequence of Failure: Segments, Score, and Total Score Legal & Regulatory Health & Safety Nature & Environmental Performance Weight (%) IIP Score Change Final Change Final Change Final Change Final Change Final Main Road Main Road River/Rail Net Under Road Urban/Rural Net 1 Airport Rd. Pump Station Line Valve at Chamber Line Valve at Chamber 23-1 Line Valve at Chamber 23-P Line Valve at Chamber 23-P13 Line Valve at Chamber 23-P Line Valve at Chamber 23-P19 Line Valve at Chamber 23-P Line Valve at Chamber 23-P25 Line Valve at Chamber Y Line Valve at Chamber Y3 Line Valve at Chamber Y Line Valve at Chamber Y6 Line Valve at Chamber Y Change 8 Line Valve at Chamber Y8 Line Valve at Chamber VC from IIP 9 Line Valve at Chamber VC-2 Line Valve at Chamber VC Score for 10 Line Valve at Chamber VC-4 Line Valve at Chamber VC each of 11 Line Valve at Chamber VC-5 Line Valve at Chamber VC the 12 Line Valve at Chamber VC-7 Line Valve at Chamber Y segments 13 Line Valve at Chamber Y-10 Line Valve at Chamber Y Line Valve at Chamber Y-11 Line Valve at Chamber Y Line Valve at Chamber Y-13 Line Valve at Chamber Y Line Valve at Chamber Y-14 Line Valve at Chamber Y Line Valve at Chamber Y-17 Line Valve at Chamber Y Line Valve at Chamber Y-20 Line Valve at Chamber Y Line Valve at Chamber Y-21 South Compartment-Maple Res Financial Total Scores Color Coding Segment Score<=80 80<Segment Score<=85 85<Segment Score<=90 90<Segment Score<=95 95<Segment Score<=100 90<Segment Score<=95 95<Segment Score<=100
25 Results: Engineering Services FE Analysis Pure Ref # STA Wire Break Range < >50 Wire Breaks (WB) Pipe Class Nearest Chamber from the Distressed Pipe Distressed Pipes: York-Peel Feeder Main Distance: Nearest Feature to the end of the distressed pipe (distress pipe length included) (m) Chamber No. 2 Drain STA * U Munro 3.1 Yes Segment Chamber No. 2 Drain STA U Munro 1.5 No Segment Valve Chamber No D Munro 3 No Segment Chamber No P D Munro 2.8 Yes Segment Drain chamber No U Munro 2 No Segment Chamber No.Y U Munro 4.4 Yes Segment AV Chamber No.Y D Munro 3.9 No Segment AV Chamber No D Hanson 2.6 Yes Segment BFV Chamber No D Hanson 6.4 Yes Segment BFV. Chamber No ** U Hanson 3.4 Yes Segment BFV. Chamber No U Hanson 5.2 Yes Segment BFV. Chamber No D Hanson 3 Yes Segment AV. Chamber No U Hanson 3.5 Yes Segment BFV. Chamber No D Munro 2.8 Yes Segment AV. Chamber No. Y D Munro 3.6 Yes Segment BFV. Chamber No. Y D Munro 3.9 No Segment BFV. Chamber No. Y D Munro 2.4 No Segment-17 Total Number Elevation basis (m) 260 Within Peel Region Flow Direction (U/D) Manufacturer Within York Region Total No. of Inspected pipe = 4280 * Pipe is 279m Upstream from feature in column G Total No. of Distressed pipe = 17 ** Distance from the nearest flange on the BFV Distress % 0.40 Peel Region Hanson Munro * The head loss was estimated based on a flow of 165 ML/Day through analysis of the pressure and flow data from the Airport Road Pump Station during the months of May and June 2013 Depth (m) Under Road (Yes/No) Invert Elevation (m) Elevation Pressure (PSI) Estimated Head Loss (Applied Uniformly Along the Pipeline) (PSI)* Total Pressure (Elevation + Est. Head Loss) (PSI) Consequence of Failure Segment (CoF) Pressure values to be adopted as current opearating conditions during the FE Analysis.
26 Results: Engineering Services FE Analysis: Curves
27 Results: Engineering Services Recommendations Leaks Address Leaks 4, 6, and 7 (Surfacing leak) 169.1m 25m 23m Leak 4: Located and addressed Leak 6: Located and addressed Leak 7: Located and addressed, located at parallel adjacent 1200mm line
28 Results: Engineering Services Recommendations Pipe Repair/Replace & Leaks Repair
29 Results: Engineering Services Recommendations Proactive Long Term Management of York Peel Feeder Main Pure Recommends One of Two Alternatives: A Installation of a Continuous Monitoring System (AFO) Live Detection and Reporting of Wire Breaks Continuously Monitor Risk (EM, AFO, Engineering ) Recommend Repeat Inspections (Leak/EM*) every 5~7 Years; Reset Re Inspection Frequency According to Results B Periodic Internal Re Inspections: Leak and EM Inspections Every 2~3 Years Reset Re Inspection Frequency According to Results
30 Questions and Discussions
CASE STUDY. Elvington To Brayton Barff Air valve replacement Program
CASE STUDY Elvington To Brayton Barff Air valve replacement Program Vent-O-Mat Anti-Shock Air valves have helped Yorkshire Water reduce maintenance costs, reduces surge and improve flows in their trunk
More informationJUST WHEN YOU HAD SEEN IT ALL: THE VALUE OF HIGH FREQUENCY PRESSURE DATA. James Dunning, CEO tel:
JUST WHEN YOU HAD SEEN IT ALL: THE VALUE OF HIGH FREQUENCY PRESSURE DATA James Dunning, CEO james.dunning@syrinix.com tel: 415-992-8040 PEOPLE DON T UNDERSTAND THE PRESSURE ON ME AGENDA Why worry about
More informationRevised Draft 2017 Development Charge Background Study and Bylaw
Revised Draft 2017 Development Charge Background Study and Bylaw Presentation to Regional Council Paul Jankowski, Commissioner of Transportation Services March 23, 2017 1 Touchpoints with Council in the
More informationMaster Control Systems, Inc. Variable Speed Fire Pump Controllers
Master Control Systems, Inc. Variable Speed Fire Pump Controllers Meets NFPA 20-2013 UL/FM Listed and Approved for fire protections 1 Why Variable Speed? Huge Sprinkler System and Standpipe Cost Savings
More informationMaster Control Systems, Inc. Variable Speed Fire Pump Controllers
Master Control Systems, Inc. Variable Speed Fire Pump Controllers Meets NFPA 20-2019 UL/FM Listed and Approved for fire protections * Pressure Limiting Control * Suction Limiting Control Why Variable Speed?
More informationTRANSPORTATION TOMORROW SURVEY
Clause No. 15 in Report No. 7 of was adopted, without amendment, by the Council of The Regional Municipality of York at its meeting held on April 17, 2014. 15 2011 TRANSPORTATION TOMORROW SURVEY recommends
More informationAppendix M. Hydraulic Transient Analysis
Water Storage and Distribution Master Plan City of Barrie October 2013 Final Appendix M Hydraulic Transient Analysis Project Number: TP110135 Appendices 131-20095-00 Wednesday October 9th, 2013 Paul Smeltzer
More informationLake to Lake LAKE YORK. CYCLING ROUTE and WALKING TRAIL FEASIBILITY and DESIGN STUDY LAKE. CITY of REGION ONTARIO SIMCOE TORONTO
LAKE SIMCOE Lake to Lake CYCLING ROUTE and WALKING TRAIL FEASIBILITY and DESIGN STUDY YORK REGION Overview Report JUNE 2013 CITY of TORONTO LAKE ONTARIO Table of Contents Study background 2 Study Background............................
More informationJournal of Applied Fluid Transients, Vol 1-1, April 2014 (3-1)
Modeling and Field Verification Study of Air Slam Conditions on kalanit Pipeline System By Yiftach Brunner & Sathish Kumar ir valves are integral part of long water transmission mains and are essential
More informationTO\fH,:>-1 0 ::: 'l, Regional Clerk's Office
YLgion I TO\fH,:>-1 0 ::: E 'l, Regional Clerk's Office A;..::S:_:T_G:::::":.!.W~I~L~l:'!IM~B~U~R!JYC..'.J Corporate Services Department March 27, 2015 Mr. Fernando Lamanna Town Clerk Town of East Gwillimbury
More informationCIPP For Large-Diameter Pressure Pipes. Andrew Costa Aegion Corporation
CIPP For Large-Diameter Pressure Pipes Andrew Costa Aegion Corporation WHAT TO EXPECT CIPP for Pressure Pipes Case Study Preliminary Condition Assessment Old Large Dia PCCP Force Main Factors for Rehabilitation
More informationTifft Water Supply Symposium
Tifft Water Supply Symposium SEPTEMBER 21-22, 2016 BUFFALO, NEW YORK Impossible Journey: Underwater Inspection of Large Diameter Water Transmission Tunnel Kristin Wheaton, PE Jim Clark Bob Clarke, P.Eng,
More informationCompiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.
1. Scope Description of requirements and procedures for compact provers to be used as verification standards. 2. Reference documents Trade Metrology Act SANS1698 3. Policy A. BASIC REQUIREMENTS Compact
More informationCLEANING, INSPECTION, AND TESTING OF SEWERS
CLEANING, INSPECTION, AND TESTING OF SEWERS PART 1 - GENERAL 1.01 SECTION INCLUDES A. Cleaning, Inspecting, and Testing Sanitary Sewers B. Cleaning, Inspecting, and Testing Storm Sewers C. Cleaning and
More informationMITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS
24 TH July 2013 MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS Vern Costelow Business Development Consultant AWMA Water Control Solutions INTRODUCTION Surface irrigation is still
More informationApplied Pressure Management Techniques to Reduce and Control Leakage
Applied Pressure Management Techniques to Reduce and Control Leakage Bambos Charalambous Head Technical Services Water Board of Lemesos, Lemesos, Cyprus Sophie Kanellopoulou Deputy Director Water Supply
More informationPressure Monitoring and Data Management System
Mueller Intelligent Water Technology Pressure Monitoring and Data Management System Gander 2017 Clean and Safe Drinking Water Workshop March 29 th, 2017 MESHING APPLICATIONS, DATA, AND NETWORKS Flush based
More informationRecent Developments in Pressure Management
Water Loss 2010 - June 06-09, 2010 São Paulo/SP Recent Developments in Pressure Management Marco Fantozzi, MIYA Allan Lambert, ILMSS Ltd The Renaissance in Pressure Management 2001: IWA International Report:Water
More information22. Specialty Valves.
22. Specialty Valves. a. Types of Specialty Valves. 1) Use of the following specialty valves is covered in this section: Altitude Valve, Pressure Reducing Valve, Pressure Relief Valve, Swing Check Valve,
More informationmy SYSTEM A guide to common applications in water distribution systems
my SYSTEM A guide to common applications in water distribution systems WWW.SINGERVALVE.COM INDEX This short guide is intended to offer guidance on some of the common problems, applications and questions
More informationSECTION 25 TESTING AND DISINFECTING WATER MAINS General
SECTION 25 TESTING AND DISINFECTING WATER MAINS 25-1.01 Scope 25-1 General This section describes the requirements for pressure and leak testing, and disinfecting of water mains and appurtenances, including
More informationTirpur Area Water Supply Project A Report on Transient Modeling Study
y February 2008 1 of 81 y INTRODUCTION: The report presents results from a transient modeling study conducted on the clear water transmission main of Tirpur Areas Water Supply Project, Tamilnadu, India.
More informationIntroduction to Emergency Response & Contingency Planning
& Contingency Planning Rationale Why is it important for you to learn this material? Designed for those who may witness a release, this is an introductory course designed to help ensure those who are likely
More informationFE Petro vs. New Red Jacket Competitive Comparison
FE Petro vs. New Red Jacket Competitive Comparison Price & Performance Comparison 1-1/2 HP FE Petro vs. New Red Jacket 140 120 1-1/2 HP Fixed Speed Pump Performance FE Petro STP150 "New" Red Jacket P150U1
More informationTECHNICAL DATA OBSOLETE
April 9, 2009 Preaction 326a 1. DESCRIPTION Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilizing the Viking G-4000P Deluge Valve. The small profi le, lightweight,
More informationSusceptibility of Distribution Systems to Negative Pressure Transients. Presenters: Kala Fleming and Mark Le Chevallier Moderator: Jian Zhang
Susceptibility of Distribution Systems to Negative Pressure Transients Presenters: Kala Fleming and Mark Le Chevallier Moderator: Jian Zhang Housekeeping Please mute your phone lines Type in questions
More informationGreenup Lock Filling and Emptying System Study
Fourth LACCEI International Latin American and Caribbean Conference for Engineering and Technology (LACCET 2006) Breaking Frontiers and Barriers in Engineering: Education, Research and Practice 21-23 June
More informationItem ID: Rev.: 00 Status: Final Effective Date: 29-Feb-2015 EXECUTIVE SUMMARY
EXECUTIVE SUMMARY The objective of this report is to demonstrate that sections of pipeline between MLV 401 and MLV 402 on the Canadian Mainline Line 400-2 meet the applicable requirements in CSA Z662-15
More informationTransient Analysis and Design Considerations for Hydraulic Pipelines. Jonathan Funk, EIT
Transient Analysis and Design Considerations for Hydraulic Pipelines Jonathan Funk, EIT Transient Analysis 2 Objectives Develop an intuitive understanding of water hammer and transient response Present
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
More informationTECHNICAL DATA. Q = C v P S
Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction
More informationTHE INFLOW OF UNWANTED AIR
IN PRESSURIZED PIPES The main reason for the inflow of air in public water distribution systems is excessive water velocity. Air traveling with water in pressurized pipes can result in high turbulence
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated
More informationAsset Integrity. We must have effective asset integrity management.
Asset Integrity We must have effective asset integrity management. follow us Mon a ktwitter i n g t h@stepchangeinfo e U K t h e s a f e s t p l a c e t o w o r k i n t h e w o r l d w i d e o i l a n
More informationPlan B Dam Breach Assessment
Plan B Dam Breach Assessment Introduction In support of the Local Sponsor permit applications to the states of Minnesota and North Dakota, a dam breach analysis for the Plan B alignment of the Fargo-Moorhead
More informationWafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1
Serial No. H-V066-E-3 Wafer Check Valve User s Manual Contents (1) Be sure to read the following description of our product warranty 1 (2) General operating instructions 2 (3) General instructions for
More informationOrange County Rail-Highway Grade Crossing Safety Enhancement Program. City of San Juan Capistrano April 17, 2012
Orange County Rail-Highway Grade Crossing Safety Enhancement Program City of San Juan Capistrano April 17, 2012 Orange County Rail-Highway Grade Crossing Safety Enhancement Program (OCX) 52 crossings 8
More informationAsheville s Fairview Water System Improvements: from Modeling to Contract Documents. April 19, 2016 Meg Roberts, PE
Asheville s Fairview Water System Improvements: from Modeling to Contract Documents April 19, 2016 Meg Roberts, PE City of Asheville Water Distribution System Customer elevations range 1,950 feet to 3,650
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More informationcurrent supply and what is needed for future conditions; this is not the total water demand for these utilities.
Southwest Missouri Water Delivery Systems, Hydraulic Analysis of Alternatives June 28, 2017 Page 2 current supply and what is needed for future conditions; this is not the total water demand for these
More informationVibration and Pulsation Analysis and Solutions
1 Vibration and Pulsation Analysis and Solutions Brian Howes, M.Sc., P.Eng. Beta Machinery Analysis Ltd. Problems created by excessive vibration in machinery can have serious economic impact. Frequently
More informationAppendix G. Alternative Solutions Details. Krosno Creek Flood Reduction Project PROJECT FILE REPORT CITY OF PICKERING
Krosno Creek Flood Reduction Project PROJECT FILE REPORT CITY OF PICKERING Appendix G Alternative Solutions Details TMIG THE MUNICIPAL INFRASTRUCTURE GROUP LTD Krosno Creek Flood Reduction Project PROJECT
More informationPractical Guide. By Steven T. Taylor, P.E., Member ASHRAE
ractical Guide The following article was published in ASHRAE Journal, March 2003. Copyright 2003 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational
More informationEffect of noise in the performance of the transducers in an ultrasonic flow meter of natural gas
23rd World Gas Conference, Amsterdam 2006 Effect of noise in the performance of the transducers in an ultrasonic flow meter of natural gas Main author R. Villarroel Venezuela TABLE OF CONTENTS 1. Abstract
More informationTECHNICAL DATA. System water supply pressure enters the priming chamber of the deluge valve (A.1) through the 1/4 (8 mm) priming line, which
January 27, 2012 307a 1. (Refer to Figures 1-3.) A Viking Non-Interlocked Preaction system utilizes a Viking Deluge Valve to control water flow into system piping equipped with closed sprinklers. Under
More informationValve Integrity Management System (VIMS) Development for Petrochina International Jabung
Managing Risk for Better Life Valve Integrity Management System (VIMS) Development for Petrochina International Jabung Dr. Budi L Hakim, MT Valve Risk and Integrity Specialist PT.WAHYU CIPTA MANDIRI Jabung,
More informationSafety. April 2018 Supersedes all previous publications 2018 Chevron Phillips Chemical Company LP
Technical Note 802 Leak Testing of Polyethylene Pipe For Municipal and Industrial Applications Part 1 Pre-Test Considerations Leak testing may be used to find leaks in a newly constructed or newly modified
More informationFailure Investigation Report. January 10, 2010 Third Party Damage to Terasen Gas Line at Bay Street and Pleasant Street, Victoria, B.C.
Failure Investigation Report January 10, 2010 Third Party Damage to Terasen Gas Line at Bay Street and Pleasant Street, Victoria, B.C. September 1, 2011 Table of Contents Incident Summary...4 Investigation
More informationSECTION PRESSURE TESTING OF PIPING
SECTION 15044 PRESSURE TESTING OF PIPING PART 1 - GENERAL 1.01 DESCRIPTION A. Scope of Work: This section specifies the leakage and pressure testing of piping. B. Testing Records: PART 2 - PRODUCTS 2.01
More informationSteam System Best Practices 14 Best Practices for Guide Lines for Boiler Plant Log Books
Steam System Best Practices 14 Best Practices for Guide Lines for Boiler Plant Log Books 1. SCOPE OF BOILER LOGBOOK PROGRAM In all cases, there are minimum tasks and functions for an operator to perform
More informationNeedle valve. Contents. User s Manual. (1) Be sure to read the following warranty clauses of our product 1. (2) General operating instructions 2
Serial No. H-V024-E-7 Needle valve User s Manual Contents (1) Be sure to read the following warranty clauses of our product 1 (2) General operating instructions 2 (3) General instructions for transportation,
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationLe Sueur County, MN Tuesday, December 13, 2016 Board Meeting
Le Sueur County, MN Tuesday, December 13, 216 Board Meeting Item 8 1:15 a.m. Darrell Pettis, County Administrator / Engineer RE: Final CSAH 3 RE: CSAH 29 Speed Zone Study RE: 4H Utilities RE: Lake Jefferson
More informationDescription of Underwater Noise Attenuation System Design Unit 2. New NY Bridge Project
New NY Bridge Project Description of Underwater Noise Attenuation System (NAS) Design Unit 2 Description of Underwater Noise Attenuation System Design Unit 2 for the New NY Bridge Project Revision 1 May
More informationCombination Air Valve
Combination Air Valve For Sewage and Wastewater Model C50 Installation, Operation and Maintenance Manual (IOM) Table of Contents General... Page 2 Safety... Page 2 Operational Data... Page 3 Materials
More information6.6 Relief Devices. Introduction
6.6 Relief Devices Introduction Relief devices are used to help prevent a catastrophic failure of equipment and/or minimize the effects of any unanticipated or uncontrolled events. As such, relief devices
More informationAnnex P Water Well Modification Plan
Annex P Water Well Modification Plan Table P1 Table P2 Summary of data Concerning Wells Sampled Summary of New Pump Characteristics H:\WP\1346\Appendices\FEIS\D - Drawdown\CamRdy\App_D.doc Annex P: Water
More informationTECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY
Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationModels 106-RF / 206-RF Rate of Flow Control Valve
Rate of Valve KEY FEATURES Accurately limits low to a pre-set maximum Easily adjustable low limit Paddle-style oriice plate included Optional oriice plate housing 106-RF Globe Product Overview The 106-RF
More informationApplication of pipeline risk assessment to proposed developments in the vicinity of high pressure Natural Gas pipelines
Communication 1737 Application of pipeline risk assessment to proposed developments in the vicinity of high pressure Natural Gas pipelines Founded 1863 Royal Charter 1929 Patron: Her Majesty the Queen
More informationTECHNICAL DATA. Q= Cv S
Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationAPPENDIX A1 - Drilling and completion work programme
APPENDIX A1 - Drilling and completion work programme Information about the well and drilling To the extent possible, the international system of units (SI) should be adhered to, and the drilling programme
More informationTECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13
Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationDecember MTS Houston Luncheon. Hoover Offshore Oil Pipeline System (HOOPS) GA-A244 Bypass and Wye Inspection
1 December 2017- MTS Houston Luncheon Hoover Offshore Oil Pipeline System (HOOPS) GA-A244 Bypass and Wye Inspection HOOPS Background Quintana Station The Hoover Offshore Oil Pipeline System (HOOPS) is
More informationManaging Leakage and Preparing for the 2012 Olympics
Water UK Leakage Conference 2012 Managing Leakage and Preparing for the 2012 Olympics Andrew Oakes Thames Water - Leakage Planning Manager Steven Harvey Thames Water - Asset Modelling and Design Specialist
More informationSubparts AA and BB - The Other RCRA Air Rules. Beginners aabb
Subparts AA and BB - The Other RCRA Air Rules Beginners aabb 1 Background Subpart AA - Process vents Subpart BB - Equipment leaks Subpart CC - Tanks, surface impoundments, containers. Also includes Subpart
More informationPIPELINE DESIGN, OPERATION AND MAINTENANCE COURSE CONTINUING PROFESSIONAL DEVELOPMENT RESULTS SHEET
E1 BASIC PIPELINE DESIGN Question Description Solution E1Q1 Calculated pipe diameter = Commercial diameter = Pipe material = 283 mm 315 mm mpvc E1Q2 E1Q3 Maximum pressure downstream of pump based on calculated
More informationThe Future of Hydraulic Control in Water-Systems
The Future of Hydraulic Control in Water-Systems A. Heimann Manager of R&D and of Technical Support & Applications Engineering departments at Dorot Automatic Control Valves Dorot Control Valves, Kibbutz
More informationPIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS. Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow
PIG MOTION AND DYNAMICS IN COMPLEX GAS NETWORKS Dr Aidan O Donoghue, Pipeline Research Limited, Glasgow A model to examine pigging and inspection of gas networks with multiple pipelines, connections and
More informationTheory, Applications and Sizing of Air Valves
Practice + Operations Theory, Applications and Sizing of Air Valves Val-Matic Valve & Mfg. Corp. When air is allowed to accumulate in pressurized pipelines, efficiency is sacrificed and serious damage
More informationDesign Criteria. Design Criteria
F Design Criteria Design Criteria Ministry of Transportation Ministère des Transports DESIGN CRITERIA Page: 1 of 13 WORK PROJECT NO. N/A GO Bloomington Station TYPE OF PROJECT LOCATION Bloomington Road
More information3 TRAFFIC CONTROL SIGNAL TIMING AND SYNCHRONIZATION
Report No. 8 of the Transportation Services Committee Regional Council Meeting of October 20, 2011 3 TRAFFIC CONTROL SIGNAL TIMING AND SYNCHRONIZATION The Transportation Services Committee recommends:
More informationTECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE
1 of 10 1. DESCRIPTION (Refer to Figures 1-3.) Viking supervised Single Interlocked Preaction Systems utilize a Viking Deluge Valve and a pneumatically pressurized automatic sprinkler system. The system
More information2 BOLTON COMMUTER RAIL SERVICE FEASIBILITY STUDY
2 BOLTON COMMUTER RAIL SERVICE FEASIBILITY STUDY The Planning and Economic Development Committee recommends the adoption of the recommendations contained in the following report dated April 15, 2011 from
More informationCOMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist
INDEX Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR COMPRESSED AIR SAVING PRODUCTS Condensate Management Specialist Information provided herewith is believed to be accurate and reliable. However,
More informationTECHNICAL DATA. Dry 132a. October 1, 2008
October 1, 2008 Dry 132a 1. Description Viking High Pressure (HP) Dry Systems utilize a Viking Model E or Model F Deluge Valve to control the water supply to system piping equipped with closed sprinklers.
More informationSEMATECH Provisional Test Method for Pressure Cycle Testing Filter Cartridges Used in UPW Distribution Systems
Provisional Test Method for Pressure Cycle Testing Filter Cartridges Used in UPW Distribution Systems Technology Transfer 92010941B-STD and the logo are registered service marks of, Inc. 1996, Inc. Provisional
More information2015 Business Plan September 2014
2015 Business Plan September 2014 Mission To Provide Superior Water Services at an Excellent Value To Provide Superior Water Services at an Excellent Value Highly Performing Staff Well Maintained Assets
More informationCharlottetown Marine Terminal Pipeline Decommissioning Project Description
Charlottetown Marine Terminal Pipeline Decommissioning Project Description 69 Marr Road Unit B Rothesay NB, E2E 3J9 Tel (506) 848-1920 Fax (506) 848-1929 Charlottetown Marine Terminal Pipeline Decommissioning
More informationOCTOBER 2017 ISSUE Page 1 of 7
Field testing is performed on fully assembled pipelines for the purpose of determining pipeline acceptability. Following visual acceptance of joints and pipeline components, pressure pipelines in their
More informationNon-Motorized Overpass at SR 5/US1
Non-Motorized Overpass at SR 5/US1 And SR 97/SW th Street (Bird Road) Executive Summary March 9, 17 Prepared By: MARLIN Engineering Inc 17 NW th Avenue, Ste. 1 Plantation, FL 33313 P: 35.77.7575 www.marlinengineering.com
More informationRisks Associated with Caissons on Ageing Offshore Facilities
Risks Associated with Caissons on Ageing Offshore Facilities D. Michael Johnson, DNV GL, Peter Joyce, BG Group, Sumeet Pabby, BG Group, Innes Lawtie, BG Group. Neil Arthur, BG Group, Paul Murray, DNV GL.
More informationBeavers are particularly adept at manipulating their
Beavers are particularly adept at manipulating their environment to suit their needs. They instinctively build dams to raise water levels and increase the area covered by water. Beaver ponds provide security
More informationINSTALLATION OPERATION MAINTENANCE
Bermad Electrically Controlled On-Off Deluge Valve Model: 400E-3D INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 1. Safety First BERMAD believes that the safety of personnel working
More informationModelling Today for the Future. Advanced Modelling Control Techniques
CwMAG 1 st Autumn Conference 2012 Modelling Today for the Future Advanced Modelling Control Techniques What are advanced modelling controls? Why do we have them? How can we use them? What are the differences
More informationAppendix D. Discussion Papers
Appendix D Discussion Papers D. Existing Transportation Conditions, Trends and Future Plans D. Transportation Demand Management D3. Role of Transit D4. Safety and Traffic Calming D. Existing Transportation
More informationIrrigation System Winterization and Pressurization Procedures
Irrigation System Winterization and Pressurization Procedures Introduction Any time that an irrigation system is filled and pressurized, or when the system is drained and water flushed from the system,
More informationHYDROVEX TTT Membrane Flow Regulator
HYDROVEX TTT Membrane Flow Regulator INSTALLATION, OPERATION AND MAINTENANCE MANUAL PROJECT EQUIPMENT LOCATION EQUIPMENT DESCRIPTION HYDROVEX TTT REFERENCE N OF THE SUPPLIER MODEL N SERIAL N DATE OF FABRICATION
More informationJanuary 25, Franklin Pasture Sanitary Sewer Cure-In-Place Pipe Lining Bid No Bid Date: 2/7/17 ADDENDUM NO 1
PUBLIC WORKS DEPARTMENT David A. Jones, P.E., Director January 25, 2017 Franklin Pasture Sanitary Sewer Cure-In-Place Pipe Lining Bid. 2017-005 Bid Date: 2/7/17 ADDENDUM NO 1 SPECIFICATION REVISIONS: QUESTIONS
More informationSpiratec ST14, ST16 and ST17 Sensor Chambers and sensors
0862050/1 IM-P086-18 MI Issue 1 Spiratec ST14, ST16 and ST17 Sensor Chambers and sensors Installation and Maintenance Instructions 1. Safety Information 2. General product information 3. Installation 4.
More information2. IMMEDIATE RESPONSE ACTIONS AND NOTIFICATION PROCEDURES
2. IMMEDIATE RESPONSE ACTIONS AND NOTIFICATION PROCEDURES This section of the GOSRP provides the general procedures to be followed at the time of an incident. The section is distinctively marked by a RED
More informationIndiana LTAP Road Scholar Core Course #10 Culvert Drainage. Presented by Thomas T. Burke, Jr., PhD, PE Christopher B. Burke Engineering, Ltd.
Indiana LTAP Road Scholar Core Course #10 Culvert Drainage Presented by Thomas T. Burke, Jr., PhD, PE Christopher B. Burke Engineering, Ltd. Objectives Review culvert shapes, end sections, and materials
More informationH.T.S.T. EQUIPMENT TEST PROCEDURES. Field Reference. Sequence of Testing. Pasteurizer Not Operating 3, 1, 4, 2, 7, 10, 8, 5B, 5E, 5C (dual stem), 9
H.T.S.T. EQUIPMENT TEST PROCEDURES Field Reference Sequence of Testing Equipment testing should be conducted in the following sequence to minimize equipment run times. Pasteurizer Not Operating 3, 1, 4,
More informationChapter 9 System Design Procedures
Chapter 9 CHAPTER 9 SYSTEM DESIGN PROCEDURES TABLE OF CONTENTS PART 9.1 GENERAL 9-1 PART 9.2 EXAMPLE 1, LOW PRESSURE GRAVITY SYSTEM 9-1 PART 9.3 EXAMPLE 2, PUMPED AUTOMATIC PRESSURE PIPELINE 9-4 9.3.1
More informationT hroughout 2003, the American National
T hroughout 2003, the American National Standards Institute issued revisions of three standards whose requirements affect the equipment and techniques used by millions of American workers and safety professionals.
More informationEmergency Action Plans for Dam Safety
Emergency Action Plans for Dam Safety Introduction to the NC EAP template Tami Idol, EI Assistant State Dam Safety Engineer Reduce risk to loss of life Determine emergency level Make notifications for
More informationPart 192 Subparts J & K. Testing & Uprating
Part 192 Subparts J & K Testing & Uprating MAOP, Testing, & Uprating Are All Linked MAOP = Maximum Pressure Allowed By Regulations (192.619 et seq.) MAOP Determined By Operator for Each Pipeline or Segment
More informationCTG Certification Protocol -- Version 3.0 SUMMARY
Date of Test: Test Report Number: SUMMARY Date of Prior Certification: Certified by: Re-certification Due Date: Unit Description: Make : Model: Serial Number: Location: CERTIFIER INFORMATION Name: Client
More informationIntro r duct u io i n o - 3 -
Finite Element Analysis in Pipeline Design using Ansys at INTECSEA Agenda: Introduction Lateral Buckling Pipeline Walking Free Span Detailed Analysis On-Shore Installation Analysis Structural Design -
More information