3-phase Line Reactor to reduce mains disturbances

Size: px
Start display at page:

Download "3-phase Line Reactor to reduce mains disturbances"

Transcription

1 DATASHEET AC Line Reactors RWK phase Line Reactor to reduce mains disturbances 2% 3-phase line reactor for 690 V network Reducing harmonics on the mains side Reducing commutation notches Limiting inrush current Reliable and economical solution for mitigating mains disturbances Approvals (UL pending) Technical specifications Performance indicators Features and benefits Ensure reliability, performance and a long service life of electrical consumers Reduction of mains harmonics and commutation notches Help to meet international power quality standards Protection of motor drive electronics and dc link capacitors against mains transients Reduction of inrush and peak currents Improvement of conducted LF immunity Prevention from nuisance tripping caused by power line voltage spikes Improvement of true power factor Nominal operating voltage Rated operating voltage Impedance Insulation class Protection category IP 00 Cooling Overload capability Ambient temperature range Transportation and storage temperature Flammability corresponding to Design corresponding to Lifetime (calculated) Earthing System Climatic category Pollution degree Overvoltage category 3x 500 to 690 VAC 3x 450 to 760 VAC 690 V, 50 Hz and rated rms current UL electrical insulation system SCH-200(N) Natural cooling AN 1.6x rated current for 1 minute, once per hour -40 C to +45 C fully operational +45 C to +100 C derated operation* Note: derating according NEC (C) -40 C to +100 C transport and storage UL 94V-0 UL , EN , EN years TN, TT, IT 40/100/21 (IEC ) PD3 *I derated = I nominal* ((T max-t amb)/(t max-t nominal)) = I nom* ((100 C-T amb)/55 C) OV III (IEC / UL ) Typical applications Motor drives and various adjustable speed drive systems, such as: Oil and gas Robots Machinery Process automation equipment Typical electrical schematic

2 2 Reactors Schaffner Group Datasheets 11 Feb 2019 Reactor selection table Reactor Rated current Rated Power* Inductance Typical Terminal V value power losses [A] [kw] [mh] [W] [kg] RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX RWK E0XXX * Calculated at rated current, 690V and cos phi= Terminals Typ Cable shoe M3 M4 M6 M8/M10/M12 Flex wire AWG Rec. torque 0.78 Nm 1.76 Nm - - Earth Screw Type Size Torque [Nm] 1.5 A M A M A M A M A M8 9.0

3 3 Reactors Schaffner Group Datasheets 11 Feb 2019 RWK 3062 Impedance vs. Voltage Product selector

4 4 Reactors Schaffner Group Mechanical data 1.5 to 21A 26 to 51A 62 to 150A 180 to 870A Datasheets 11 Feb 2019

5 5 Reactors Schaffner Group Datasheets 11 Feb 2019 Dimensions* RWK 3062 A B±5 C±3 D E F G H J K L±5 M±5 N±5 O P Q R x M2.5 24± x M3 31.1± x M3 41.5± x M3 41.5± x M3 41.5± x M4 50± x M4 50± x9 ø M4 50± x9 ø M4 50± x9 ø M6 60± x9 ø M6 68± x9 2.5 M ± ø x11 3 M ± ø x11 3 M ± ø x11 3 M ± ø x11 3 M ± ø x11 n/a 3 M ø x11 ø20 3 M ø x11 ø20 3 M ø x11 ø20 3 M ø x11 ø20 3 M ø ± x11 ø20 3 M ø ± x11 ø20 3 M ø ± x11 ø20 3 M ø ± x11 ø20 3 M ø13.5 * General tolerance: ISO 2768-v All dimensions (and tolerance) are in mm.

6 6 Reactors Schaffner Group Datasheets 11 Feb 2019 Headquarters, global innovation and development Sales and application centers Switzerland Schaffner Group Nordstrasse Luterbach T info@schaffner.com To find your local partner within Schaffner s global network: Schaffner Group The content of this document has been carefully checked and understood. However, neither Schaffner nor its subsidiaries assume any liability whatsoever for any errors or inaccuracies of this document and the consequences thereof. Published specifications are subject to change without notice. Product suitability for any area of application must ultimately be determined by the customer. In all cases, products must never be operated outside their published specifications. Schaffner does not guarantee the availability of all published products. This disclaimer shall be governed by substantive Swiss law and resulting disputes shall be settled by the courts at the place of business of Schaffner Holding AG. Latest publications and a complete disclaimer can be downloaded from the Schaffner website. All trademarks recognized. China Schaffner EMC Ltd. Shanghai T20-3 C, No 565 Chuangye Road, Pudong district Shanghai T cschina@schaffner.com Finland Schaffner Oy Sauvonrinne 19 H Lohja T finlandsales@schaffner.com France Schaffner EMC S.A.S Rue Louis Rameau Bezons T F francesales@schaffner.com Germany Schaffner Deutschland GmbH Schoemperlenstrasse 12B Karlsruhe T F germanysales@schaffner.com India Schaffner India Pvt. Ltd REGUS WORLD TRADE CENTRE WTC, 22nd Floor Unit No 2238, Brigade Gateway Campus, 26/1, Dr. Rajkumar Road Malleshwaram (W) Bangalore T indiasales@schaffner.com Italy Schaffner EMC S.r.l. Via Ticino, Monza (MB) T italysales@schaffner.com Japan Schaffner EMC K.K , Kamiuma, Setagaya-ku 7F Mitsui-seimei Sangenjaya Bldg Tokyo T F japansales@schaffner.com Singapore Schaffner EMC Pte Ltd. #05-09, Kg Ubi Ind. Estate Singapore T F singaporesales@schaffner.com Spain Schaffner EMC España Calle Caléndula 93, Miniparc III, Edificio E El Soto de Moraleja, Alcobendas Madrid T F spainsales@schaffner.com Sweden Schaffner EMC AB Tegeluddsvägen 76, 2tr Stockholm T swedensales@schaffner.com Switzerland Schaffner EMV AG Nordstrasse Luterbach T switzerlandsales@schaffner.com Taiwan R.O.C. Schaffner EMV Ltd. 20 Floor-2, No 97, Section 1, XinTai 5th Road XiZhi District New Taipei City T F taiwansales@schaffner.com Thailand Schaffner EMC Co. Ltd. Northern Region Industrial Estate 67 Moo 4 Tambon Ban Klang Amphur Muangg P.O. Box Lamphun T F thailandsales@schaffner.com United Kingdom Schaffner Ltd. 5 Ashville Way, Molly Millars Lane Wokingham RG41 2PL Berkshire T F uksales@schaffner.com USA Schaffner EMC Inc. 52 Mayfield Avenue Edison, New Jersey T F usasales@schaffner.com Schaffner North America 6722 Thirlane Road Roanoke, Virginia T F Schaffner North America 823 Fairview Road Wytheville, Virginia T F

Versatile Filtered Power Entry Module

Versatile Filtered Power Entry Module DATASHEET IEC Inlet Filters FN 390 Versatile Filtered Power Entry Module Rated currents up to 10 A For one or two fuses Fuses Ø6.3 x 32 mm or Ø5 x 20 mm 2-pole rocker switch Voltage selector Optional earth

More information

Power Quality Increased Reliability. Components

Power Quality Increased Reliability. Components Increased Reliability Components schaffner Group Schaffner quoted on the Swiss stock exchange since 1998 is the international leader in electromagnetic compatibility (EMC) and power quality, focusing on

More information

1-phase Filters FN Multi-stage General Purpose EMI Filter. Approvals. Typical electrical schematic. Technical specifications

1-phase Filters FN Multi-stage General Purpose EMI Filter. Approvals. Typical electrical schematic. Technical specifications 1-phase ilters 2060 ulti-stage eneral Purpose E ilter n Rated currents from 1 to 30 n igh differential and common-mode attenuation n Optional medical versions (B type) n Optional safety versions ( type)

More information

1-phase Filters FN Multi-stage High Performance EMI Filter. Approvals. Technical specifications. Typical electrical schematic

1-phase Filters FN Multi-stage High Performance EMI Filter. Approvals. Technical specifications. Typical electrical schematic 1-phase ilters 2080 ulti-stage igh erformance EI ilter n Rated currents from 1 to 16 n igh differential and common-mode attenuation n ood low frequency attenuation n ptional medical versions (B type) n

More information

1-phase Filters FN Multi-stage Performance EMI Filter. Approvals. Typical electrical schematic. Technical specifications. Typical applications

1-phase Filters FN Multi-stage Performance EMI Filter. Approvals. Typical electrical schematic. Technical specifications. Typical applications 1-phase ilters 2070 ulti-stage erformance E ilter n Rated currents from 1 to 36 n igh differential and common-mode attenuation n igh frequency attenuation n ptional medical versions (B type) n ptional

More information

FMAC Sine FMAC Sine DCL

FMAC Sine FMAC Sine DCL emc Sine Output Filter www.schurter.com/pg8 FMAC Sine FMAC Sine DCL -Phase Filters Sine wave output filter Description - Design corresponding to UL 128, CSA 22.2 No. 8, IEC/EN699 - Standard versions include

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel Diaphragm Pressure Switch measuring monitoring analysing SCH-27 P3 Setting range: 0.7... 6 mbar to 8... 160 bar Temperature: max. +100 C Material: stainless steel Connection: G ½ male, ½" NPT male, ¼"

More information

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential Pressure Control Types MP 54, MP 55 and MP 55A MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration

More information

Differential pressure switch MP 54, MP 55 and MP 55A

Differential pressure switch MP 54, MP 55 and MP 55A Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating

More information

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17

CONTENTS TABLE OF MAIDA S HISTORY TERMINOLOGY & GENERAL SPECIFICATIONS. iii. LEAD CODES and TAPE & REEL STANDARD SERIES 1 HC SERIES 17 TABLE OF CONTENTS MAIDA S HISTORY TERMINOLOGY & GENERAL LEAD CODES and TAPE & REEL i ii iii STANDARD SERIES 1 HC SERIES 17 LOW PROFILE SERIES 33 THERMALLY PROTECTED SERIES 39 HIGH ENERGY SERIES LEAD CODES

More information

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available

Watts. xppower.com. Input. General. Environmental. Output. EMC & Safety. Output Voltages from 2.5 V to 48 V. Non-standard Outputs Available -0 Watts AEH Series s from. V to 8 V xppower.com Non-standard s Available Universal Input Single & Multiple Versions 0 C to +60 C Operating Temperature Efficiency up to 80% Non-standard Connectors Available

More information

FEATURES AND BENEFITS. Meets UL/EN/IEC , 4Th ed. For EMC*

FEATURES AND BENEFITS. Meets UL/EN/IEC , 4Th ed. For EMC* LPS Medical FEATURES AND BENEFITS Meets UL/EN/IEC60601-1-2, 4Th ed. For EMC* Approved To EN/IEC/UL60601-1, 3rd edition With Isolation Levels Which Satisfy The 2 MOPP Requirements Meets DoE Efficiency Level

More information

Zener Diodes with Surge Current Specification

Zener Diodes with Surge Current Specification Zener Diodes with Surge Current Specification DESIGN SUPPORT TOOLS Models Available 949588 click logo to get started FEATURES Glass passivated junction Hermetically sealed package Clamping time in picoseconds

More information

Applications. What moves your world

Applications. What moves your world Digital Control Proportional Valves Series D92 High-performance pressure control valve with high dynamics and the ability to easily and exactly tune the pressure controller gain The pq-proportional valves

More information

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6

P9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6 P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,

More information

Efficient EMC Solutions

Efficient EMC Solutions www.schurter.com/emc EMC Products & Services Efficient EMC Solutions > EMC-Competence 02 03 www.schurter.com SCHURTER has the capabilities and expertise to ensure electromagnetic compliance (EMC), in order

More information

End stops for mobile cranes & crawler cranes. verope Special Wire Ropes

End stops for mobile cranes & crawler cranes. verope Special Wire Ropes s for mobile cranes & crawler cranes verope Special Wire Ropes Construction Industry applications The construction industry has never been more complex, building projects constantly increase. This means

More information

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS CONSTRUCTION FEATURES ENCLOSURE OPERATING TEMPERATURE 20 C/+60 C COVER Diecast aluminium (anodised) WEIGHT CSN 5 3.5 kg CSN 8 5 kg CSN

More information

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM

GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM GAS SAMPLING PUMPS WITH KNF DOUBLE DIAPHRAGM SYSTEM DATA SHEET E065 Cutaway - Double diaphragm pump Concept The Diaphragm Vacuum Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed

More information

EPRB-2 Pressure Transducer

EPRB-2 Pressure Transducer Small size with amplified output Any liquid or gas media compatible with stainless steel Operating temperature up to 150 C (300 F) Variety of pressure ports Available as gage and absolute CE approved DESCRIPTION

More information

VLT 2000 Series. How to size your VLT

VLT 2000 Series. How to size your VLT Selection of frequency converter Usually the size of frequency converter is chosen on the basis of the shaft output, as this may be the only value known. However, if the data are known for both the application,

More information

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE

More information

Type 715P/717P, Orange Drop, High Voltage, Polypropylene Film/Foil

Type 715P/717P, Orange Drop, High Voltage, Polypropylene Film/Foil Type 715P/717P are high AC voltage, film/foil polypropylene capacitors. Well suited for high AC voltage applications requiring corona free performacnce. These capacitors are ideal in high frequency, high

More information

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom NE ASM Asynchronous Spindle Motors SEM Limited Faraday Way Orpington, Kent BR 3QT United Kingdom Tel: +44 ()189 8847 Fax: +44 ()189 884884 Email: sales@sem.co.uk Web: www.sem.co.uk Version 4 August 2 Asynchronous

More information

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor Cat No AP3-KA-C Two-color digital display pressure sensor AP-3 Series Digital Display & Digital Control For Air Pressure EASY-TO-SEE 2-color display Green and red two-color LED display clearly shows abnormal

More information

EX-RECESSED CEILING LIGHT FITTINGS

EX-RECESSED CEILING LIGHT FITTINGS EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic

More information

TeSys protection components

TeSys protection components Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively

More information

Meta-MEC Manual Motor Starters

Meta-MEC Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM VACUUM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 015 N 920 APE-W Automatic voltage adjustment for worldwide use (as an option with external signal input). N 920 APDC-B with brushless DC

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

Application Notes. Aluminium Electrolytic Capacitors

Application Notes. Aluminium Electrolytic Capacitors Application Notes Aluminium Electrolytic Capacitors , now part of the Evox Rifa Group, is one of Europe s leading manufacturers of Large Can Aluminium Capacitors. The Evox Rifa Group is a major global

More information

DIAPHRAGM GAS SAMPLING PUMPS

DIAPHRAGM GAS SAMPLING PUMPS DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 0150 N 0150 SP.9 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central point

More information

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply

Sorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply Sensen DCS Series General Purpose Systems Power Supply High power density / low ripple and noise High programming resolution with Ethernet interface Constant voltage and current mode Remote sensing Isolated

More information

ibridge and ibridge Ultra

ibridge and ibridge Ultra 2.00 mm Board to Cable Connectors ED. 06 10.2016 Catalog EA IB001 erni.com erni.cn TABLE OF CONTENTS OVERVIEW General 03 Technical Details 04 Features 05 Electrical and Mechanical Characteristics 10 Ordering

More information

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts:

EPIC Rectangular Connector Inserts. HBE Series. Technical Data Number of Contacts: HBE Series HBE series inserts provide reliable termination and performance in the vast majority of medium power and control applications. Methods of termination include screw, crimp, and spring cage clamp.

More information

Relative pressure transmitter type 520

Relative pressure transmitter type 520 Relative pressure transmitter type 520 Pressure range -1... 9 bar / 0... 2.5 1000 bar The compact type 520 pressure transmitter is based upon the Huba Control developed thick film technology where the

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET N 186 N 186.1.2 ST.12 E Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down

More information

PIKO IQ 4.2, Plenticore plus 4.2 Rating: 10,0kW 8,5kW 7,0kW 5,5kW 4,2kW Rated voltage: PIKO IQ 8.5, Plenticore plus 8.5

PIKO IQ 4.2, Plenticore plus 4.2 Rating: 10,0kW 8,5kW 7,0kW 5,5kW 4,2kW Rated voltage: PIKO IQ 8.5, Plenticore plus 8.5 Applicant: Product: Certificate of conformity Generating unit, NS-protection KOSTAL Solar Electric GmbH Hanferstraße 6 79108 Freiburg i. Br. Germany Photovoltaic Inverter with integrated NS-protection

More information

Differential pressure controls, Type MP 54, 55 and 55A

Differential pressure controls, Type MP 54, 55 and 55A MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors

More information

ASB Accumulator Safety Blocks

ASB Accumulator Safety Blocks ASB Accumulator Safety Blocks For working pressures up to 350 bar Catalogue HY07-1241/UK Note: In line with our policy of continuing product improvement, specifications in this catalogue are subject to

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2015-01-30 Page 1 of 24 Report Reference # E186249-A270-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 Data sheet Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 The CCMT is an electrically operated valve designed specifically for operation in CO 2 systems. The CCMT valve concept is

More information

Certificate of compliance

Certificate of compliance Bureau Veritas Consumer Products Services Germany GmbH Businesspark A96 86842 Türkheim Germany + 49 (0) 40 740 41 0 cps-tuerkheim@de.bureauveritas.com Certification body of BV CPS GmbH Accredited according

More information

N SERIES PROCESS VACUUM PUMPS AND COMPRESSORS

N SERIES PROCESS VACUUM PUMPS AND COMPRESSORS N 186.1.2 SERIES PROCESS VACUUM PUMPS AND COMPRESSORS ADVANTAGES Twofold safety: The combination of a working diaphragm and an additional safety diaphragm prevents gas from escaping in the event of a fracture

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 16 N 35 ANE with IP 2 motor Concept The diaphragm pumps from KNF are based on a simple principal - an elastic diaphragm, ixed on its edge, moves up and

More information

HYBRID STEPPING MOTORS HY / HS / HN Series

HYBRID STEPPING MOTORS HY / HS / HN Series HYBRID STEPPING MOTORS HY / HS / HN Series Long Life Compact Design Bipolar / Unipolar Models Holding Torque up to High Performances Series HS and HN Several Options available (Encoders, Gearboxes,Cables,

More information

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 9 N 9 FTE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its

More information

h2000 plus HyDROGEN LEAk DETECTOR

h2000 plus HyDROGEN LEAk DETECTOR H2000 plus hydrogen leak detector hydrogen leak detector h2000 plus Fast, easy to use, and durable. Leak testing with Hydrogen tracer gas The Hydrogen Method Detecting leaks using Hydrogen, called the

More information

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass

More information

Global Economic Briefing: Industrial Production

Global Economic Briefing: Industrial Production Global Economic Briefing: Industrial Production November 27, 2017 Dr. Edward Yardeni 516-972-7683 eyardeni@ Debbie Johnson 4-664-1333 djohnson@ Mali Quintana 4-664-1333 aquintana@ Please visit our sites

More information

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS

CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS CHEMICALLY RESISTANT DIAPHRAGM GAS SAMPLING PUMPS DATA SHEET N 922 N 922 FTE Concept The diaphragm pumps from KNF are based on a simple principle - an elastic diaphragm, ixed on its edge, moves up and

More information

Dialight LED Conveyor Light - CE / RCM. for Indoor and Outdoor Industrial Applications

Dialight LED Conveyor Light - CE / RCM. for Indoor and Outdoor Industrial Applications Dialight LED Conveyor Light - CE / RCM for Indoor and Outdoor Industrial Applications Conveyor Light Products Vigilant LED Conveyor Light - CE / RCM Standard Model Mechanical Information: Fixture weight:

More information

TERMINAL BLOCK SUMMARY

TERMINAL BLOCK SUMMARY TERMINAL BLOCK SUMMARY TERMINAL BLOCK SUMMARY TERMINAL BLOCK SUMMARY FEEDTHROUGH TERMINALS FUSE TERMINALS DISCONNECT TERMINALS MICRO TERMINALS CIRCUIT BREAKERS PRODUCT INFORMATION Feedthrough Terminals

More information

Medium Power Film Capacitors

Medium Power Film Capacitors GENERAL DESCRIPTION Metallized polypropylene dielectric capacitor with controlled self-healing. Reinforced metallization developed for high impulse currents. APPLICATIONS IGBT protection IGBT clamping

More information

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

MINI DIAPHRAGM VACUUM PUMPS

MINI DIAPHRAGM VACUUM PUMPS MINI DIAPHRAGM VACUUM PUMPS DATA SHEET E 024 N 815 KNE N 828 KNDC-B N 838 KNDC Concept The mini diaphragm gas sampling pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge,

More information

Principal Operations in Japan

Principal Operations in Japan Principal Operations in Japan 5 0 5 5 0 Production Facilities Mie Plant Mishima Plant Onomichi Plant Shinshiro Plant Shinshiro-Minami Plant Hiratsuka Factory Hamatite Plant Hiratsuka-Higashi Plant Ibaraki

More information

WAGO-I/O-SYSTEM 750 XTR Taking it to the extreme The Standard for 750 XTR

WAGO-I/O-SYSTEM 750 XTR Taking it to the extreme The Standard for 750 XTR WAGO-I/O-SYSTEM 750 XTR Taking it to the extreme The Standard for 750 XTR TAKING IT TO THE extreme The Standard for 750 XTR extreme temperatures extreme isolation extreme vibrations from 40 C to +70 C

More information

Automatic Control Unit. Controlmatic E.2. Type Series Booklet

Automatic Control Unit. Controlmatic E.2. Type Series Booklet Automatic Control Unit Controlmatic E.2 Type Series Booklet Legal information/copyright Type Series Booklet Controlmatic E.2 All rights reserved. The contents provided herein must neither be distributed,

More information

Relative and differential pressure transmitter type 692

Relative and differential pressure transmitter type 692 Relative and differential pressure transmitter type 692 Pressure range 0... 0.1 25 bar Type 692 pressure transmitters have a unique, well proven ceramic technolgy. There are variety of pressure and electrical

More information

Conductor Bushings Series 8174

Conductor Bushings Series 8174 > Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The

More information

stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with encoder / brake

stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with encoder / brake stepper motor 2-phase hybrid stepper motor (bipolar) high protection class with plug or stranded wires optional with / brake / 9 www.igus.de MOT-AN-S_EN_2070# part number (not configurable, only for illustration)

More information

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

Mx2 system take control

Mx2 system take control 1 Mx2 system take control mx2 system welcome to a new dimension Bien-Air has positioned itself as the world leader in electric micromotors. And this has not happened by chance. Some have even revolutionised

More information

Protection of motor circuits

Protection of motor circuits Protection of motor circuits Circuit breaker/contactor coordination A circuit supplying a motor may include one, two, three or four switchgear or When a number of devices are used, they must be coordinated

More information

Design Rules for PFC Systems

Design Rules for PFC Systems P o w e r Q u a l i t y S o l u t i o n s www.epcos.com/pfc The collection of PQS is a library with in-depth information on PFC applications, case studies and reference projects. It also serves as a helpdesk

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications.

Sanitary RTD Temperature sensor TH17. Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications. Sanitary RTD Temperature sensor TH17 Compact Instructions Measuring System Sanitary RTD assembly with connection head TH17 for food and dairy applications. The single element RTD is specifi cally designed

More information

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application: MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS N26.1, N26.2, N26.3 N 26.1 ANE Concept The Diaphragm Vacuum Pumps from KNF are based on a simple principal - an elastic diaphragm, fixed on its edge, moves up and

More information

Gas Generators AB Sciex Range

Gas Generators AB Sciex Range Gas Generators AB Sciex Range Introducing Over the years our dynamic company has stimulated Peak design engineers into some remarkable developments in manufacturing Laboratory Gas Generators. These clever

More information

Talas Measurer 250VDC Datasheet

Talas Measurer 250VDC Datasheet Talas Measurer 250VDC Datasheet KEY FEATURES Automatic insulation resistance monitoring AC and DC motors MODBUS protocol M2M-modem communication Monitor from any computer or smart device Adjustable automatic

More information

PVK OPEN LOOP PUMPS. Bulletin E

PVK OPEN LOOP PUMPS. Bulletin E PVK OPEN LOOP PUMPS Bulletin 47025-E Table of Contents Performance Assurance page 3 Features and Benefits page 4-5 Specifications page 6 Pump Controls page 7 Table of Contents Curves Performance page 8

More information

Quick Reference Guide Power Series Switches

Quick Reference Guide Power Series Switches Quick Reference Guide The Power Series employs a Quick-make/Quick-break wiping action contact mechanism. This highspeed movement reduces the teasing of the contact surfaces reducing pitting due to arcing.

More information

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations

Models EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization

More information

Heinen & Hopman Engineering

Heinen & Hopman Engineering Navy Heinen & Hopman Engineering Founded in 1965, Heinen & Hopman Engineering is a world leader in air-conditioning, mechanical ventilation, central heating, sanitary systems, fire protection, environmental

More information

GENERAL APPLICATION NOTES

GENERAL APPLICATION NOTES GENERAL APPLICATION NOTES There are common considerations when using our connectors. Additional considerations may apply based on the particular connector being used, the application, and conditions in

More information

.... AC drive to. 7.5 kw... 1 HP to 10 HP...

.... AC drive to. 7.5 kw... 1 HP to 10 HP... Commander SX IP66, Nema 4X AC drive 075 to 75 kw 1 HP to 10 HP Commander SX - for tough environments 10V ADI1 0V ADI2 0V AIO3 DIO1 +24V DI2 DI3 +24V DI4 SDI1 SDI2 COM RL1O RL1C SDO1 SDO2 0-10V analog reference

More information

CMC Series Moulded Case Circuit Breaker Cielo Electric

CMC Series Moulded Case Circuit Breaker Cielo Electric Model name CMC: Series 225: mpere frame size Line side terminal In: Rated current Ue: Rated operational voltage Icu: Rated ultimate short-circuit breaking capacity Ta: mbient temperature In: 225 Icu: 55k@415V

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) VS Series Leak Detectors for Vacuum Furnaces Rate of rise and vacuum decay tests will not locate leaks, they will only

More information

RTD Temperature sensor TH11

RTD Temperature sensor TH11 RTD Temperature sensor TH11 Compact Instructions Measuring System General purpose RTD with connection head TH11 for process and laboratory applications. The single element RTD is specifi cally designed

More information

Pushbuttons and Indicating Lights

Pushbuttons and Indicating Lights Pushbuttons and Indicating Lights Pushbuttons Indicating Lights Emergency Stops Selector Switches.5 Product Overview.............................................. 2 Product Selection Guide.........................................

More information

Relative pressure switch type 521

Relative pressure switch type 521 Relative pressure switch type 521 Pressure range 0... 2.5 600 bar The compact type 521 pressure switch is based upon the Huba Control developed thick film technology where the pressure measuring cell is

More information

Compact pressure switches for gas and air

Compact pressure switches for gas and air Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The

More information

Pressure switches for air and water CS

Pressure switches for air and water CS Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the

More information

Marsh & McLennan Companies Entities Covered by the BCRs

Marsh & McLennan Companies Entities Covered by the BCRs Marsh & McLennan Companies Entities Covered by the BCRs The Marsh and McLennan Companies Binding Corporate Rules (BCRs) are a means of transferring personal data internationally within the Marsh & McLennan

More information

JSP. MKT Series J S P -

JSP. MKT Series J S P - Loose Taped Fig.1 Fig. 2 JSP Typical applications: blocking, coupling, decoupling, by-passing, interference suppression in low voltage applications (i.e.:automotive) Ød ±0.05 All dimensions are in mm.

More information

X2 Metallized Polypropylene Film Capacitor JFV

X2 Metallized Polypropylene Film Capacitor JFV FEATURES: Non-inductive, (UL940V-0) plastic case sealed with epoxy resin. Provides interference suppression with VDE, ENEC and UL approvals. SPECIFICATIONS: Operating Temperature -40 ~ +110 Maximum Continuous

More information

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners 7 634 VGS1... with AGA67 connector VGS2... with AGA67 connector Solenoid gas valve VGS The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners The VGS and

More information

Dräger CAPITANO 140 Mobile Compressor

Dräger CAPITANO 140 Mobile Compressor Dräger CAPITANO 140 Mobile Compressor The true capabilities of the Dräger CAPITANO 140 mobile compressor become apparent during professional operations at sea. Filling tube with filling valve Handle Fan

More information

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction Series/Type: Ordering code: Date: November 2009 Version: 2 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the

More information

RELAY PRODUCT GUIDE CONTENTS

RELAY PRODUCT GUIDE CONTENTS RELAY PRODUCT GUIDE CONTENTS 1.0 ABOUT FUJITSU COMPONENTS 1.1 Who we are Page 2 2.0 PRODUCT LINE-UP 2.1 Automotive relays Page 3 2.2 Power relays Page 8 2.3 Signal relays Page 16 2.4 High frequency relays

More information

Aluminum Capacitors +85 C, Miniature, Axial Lead

Aluminum Capacitors +85 C, Miniature, Axial Lead Aluminum Capacitors +85 C, Miniature, Axial Lead FEATURES High CV per case size Material categorization: for definitions of compliance please see www.vishay.com/doc?99912 QUICK REFERENCE DATA DESCRIPTION

More information

Operating Instructions Rope Pull Switches RPS...

Operating Instructions Rope Pull Switches RPS... Safety rope pull switch RPS Correct use In accordance with EN 60947-5-5, EN ISO 13850, it must be ensured that parts of or complete industrial machines or installations can be stopped as quickly as possible

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

Safety Rope Pull Switches SR and SRM

Safety Rope Pull Switches SR and SRM Safety Rope Pull Switches SR and SRM Safety Rope Pull Switches For more safety on the production line Whether on the conveyor belt or on the machine when maximum safety is required, BERNSTEIN rope pull

More information

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Limit switches OsiSense XC Special For material handling applications, type XC1 AC Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics

More information

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS

DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DIAPHRAGM VACUUM PUMPS AND COMPRESSORS DATA SHEET E 14 N 22 ANE Concept The diaphragm pumps from KNF are based on a simple principle an elastic diaphragm, ixed on its edge, moves up and down its central

More information