Safety Edges Safedge Profiles Specifications

Size: px
Start display at page:

Download "Safety Edges Safedge Profiles Specifications"

Transcription

1 Presence Sensing Safety evices Specifications The ability of the Safedge profile to out perform competition lies in its innovative design. It uses a combination of non conductive rubber and flexible wire cored conductive rubber bonded together so it keeps bouncing back into shape even after repeated compressions. The Safedge profiles come in 3 different cushions factors: 5mm (0.2in), 19mm (0.75in) and 41mm (1.6in). ushion factor is the distance the profile can be depressed after a signal has been generated. The profiles are also offered with a sealing lip which is designed to reduce drafts between the profile and opposing surface. The profiles come in two different materials. Use the P material in the presence of conductive fluids. The R/R material performs better in the presence of oils. Review the chemical resistance chart to help make the best choice of material. If in doubt, a small sample of the profile should be tested for chemical resistance before a final selection is made. The Safedge profile has no rigid internal parts which can break through or cause fatigue failures after prolonged use. The multistranded copper wire core throughout the length of the strip insures that there are no problems of resistance build up on long lengths. eatures Various profiles onductive rubber technology Up to 50m lengths luminium, plastic or zinc coated steel, mounting rails Rubber boot optional ctive corners Sealing lip available Standards pprovals Power supply Operating temperature P material R/R material umidity , 954-1, ISO , I/ , SI 11.19, S marked for all applicable directives, culus and TÜV, c-tick not required Operates on 4V supplied from control unit -5 to +55 (23 to 131 ) 0 to + 55 (32 to 131 ) 90% R nclosure Protection IP67 ( 6P) onductor Size (18W) aterials P ounting Weight R/R thylene Propylene iene odified Rubber crylonitrile (34% nitrile) utadiene Rubber/hloropriene Rubber ny position using Type 112 rail See Ordering etails hemical Resistance of Safedge Profile Substance Resistance S Profile P Resistance Profile R/R cetic cid (%) ood ood cetone ood air mmonium ydroxide (35%) ood ood enzene Poor Poor iesel Oil Poor ood thyl lcohol (thanol) ood ood ydrochloric cid (%) ood ood Lubricating Oil Poor ood itric cid (%) ood air Petrol Poor air Silicone luids ood ood Sodium hloride (25%) ood ood Trichlorethylene ood Poor Vegetable Oils (general) ood ood Water (distilled) ood ood Water (sea) ood ood 2-94

2 43 (1.69) 43 (1.69) Product Selection Profiles Presence Sensing Safety evices (Page 2-0) imension Profile ushion actor 24.5 (0.96) 01S lack, P, Weight: 463g/m (0.33lbs/ft) 5mm Length m (ft) atalogue umber 5 (16.4) S05 (32.8) S 20 (65.6) S (0.96) 01 lack, R/R, Weight: 460g/m (0.31lbs/ft) 5mm 5 (16.4) (32.8) (65.6) (0.96) 01R Red, P, Weight: 502g/m (0.34lbs/ft) 5mm 5 (16.4) R05 (32.8) R 20 (65.6) R20 14 (0.55) 16S lack, P, Weight: 843g/m (0.57lbs/ft) 19mm 5 (16.4) S05 (32.8) S 20 (65.6) S20 14 (0.55) 16 lack, R/R, Weight: 837g/m (0.56lbs/ft) 19mm 5 (16.4) (32.8) (65.6) (2.68) 36 (1.42) 30 (1.18) 03S lack, P, Weight: 1209g/m (0.81lbs/ft) 41mm 5 (16.4) S05 (32.8) S 20 (65.6) S (0.96), 05S ( ) lack, P, with Sealing Lip Weight: 545g/m (0.37lbs/ft) 5mm 5 (16.4) S05 (32.8) S 20 (65.6) S20 43 (1.69) 14 (0.55), 0804S 17 (0.67) lack, P, with Sealing Lip Weight: 13g/m (0.68lbs/ft) 19mm 5 (16.4) S05 (32.8) S 20 (65.6) S

3 67 (2.64) 16 (0.63) 68 (2.68) 36 (1.42) Presence Sensing Safety evices Product Selection Profiles (Page 2-0) imension Profile ushion actor 30 (1.18) I, L 02S 29 (1.14) lack, P, with Sealing Lip Weight: 1291g/m (0.87lbs/ft) 41mm (1.61in) Length m (ft) atalogue umber 5 (16.4) S05 (32.8) S 20 (65.6) S20 18 (0.71) 0118S lack, P Weight: 242g/m (0.163lbs/ft) 3.75mm (0.15in) 5 (16.4) S05 (32.8) S 20 (65.6) S20 50 (1.97), O 1111S lack, P Weight: 680g/m (0.457lbs/ft) 5 (16.4) S05 (32.8) S 20 (65.6) S

4 Product Selection Rails Presence Sensing Safety evices imension mm (inches) atalogue umber I 18 (0.71) 8.5 (0.33) 20 (0.79) 18 (0.71) luminium type; Type 112/. 3m (9.8ft) length Weight: 258g/m (0.17lbs/ft) Zinc-oated Steel; Type 112/S 2m (6.5ft) length Weight: 663g/m (0.45lbs/ft) PV lack; Type 112/P 3m (9.8ft) length Weight: 111g/m (0.07lbs/ft) PV Red; Type 112/PR 3m (9.8ft) length Weight: 111g/m (0.07lbs/ft) PV Yellow; Type 112/PY 3m (9.8ft) length Weight: 111g/m (0.07lbs/ft) luminium Vertical Lip; Type 112/ 2 2m (6.5ft) length Weight: 368g/m (0.25lbs/ft) luminium orizontal Lip; Type 112/3 2m (6.5ft) length Weight: 388g/m (0.26lbs/ft) luminium eep hannel; Type 112/4 2m (6.5ft) length Weight: 345g/m (0.23lbs/ft) luminium; Suitable for ini Profile Only 2m (6.5ft) length Weight: 150g/m ( lbs/ft) 440-R R R1212P 440-R1212PR 440-R1212PY 440-R R R R (0.51) 45 (1.77) luminium Suitable for Rubber oot Only?m (ft) length Weight: 667g/m (0.448lbs/ft) 440-R2151 (0.4) 45 (1.77) luminium nd Plate for -Rail Option 2 Plates 4 Screws, flat head, Philips, mm, #6, Weight: 7g (0.01lbs) 440-R

5 Presence Sensing Safety evices Product Selection omponent Parts imension ame atalogue umber onnector and able 1m 2m 5m 12m 15m Terminator 6kΩ (yellow) resistor for series termination 15kΩ (blue) for parallel termination losing ap losing ap material: P losing ap material: R S losing ap To close profiles S and S. To close profiles S xial onnector With this connector you can directly connect two profiles. Suitable for S and R profiles S Straight Pin onnector 90 orner onnector 90 orner onnector (vertical) it contains one pair of pins suitable for one joint. When using profile S select When using profile R select When using profile select When using profile S select When using profile S select When using profile select When using profile select When using profile S or R select When using profile select When using profile S select When using profile S select S IS I S S S S S 45 orner onnector When using profile orner onnector When using profile

6 Product Selection omponent Parts Presence Sensing Safety evices imension ame atalogue umber Use only on ini Profile 1m onnector and able Use only on ini Profile 3m Use only on ini Profile 5m Terminator Use only on ini Profile 8kΩ (yellow) resistor for series termination losing ap Use only on ini Profile losing ap material: P yanocrylate dhesive ontents: 3g. Sufficient for approximately terminations Shears Use to cut profiles onnection ox Polycarbonate housing 53mm X 53mm X 35mm complete with two pole terminal and trumpet type screw on connector with strain and relief clamp. or use with coiled cable oiled onnection able 2.5m (8.2ft) (extended) of flexible coiled cable m (11.5ft) (extended) of flexible coiled cable onnection ox ontrol Unit losing ap onnector with Resistor Rail onnection ox oiled able xample application of profile using coiled cable. The coiled cable can not be directly connected to the profile due to the weight of the cable. The proper use of the coiled cable is to connect the coiled cable to the profile through the connection box. The coiled cable should be secured to both the moving and stationary objects so as to prevent straining of the terminal connections. able onnector losing ap 2-99

7 Presence Sensing Safety evices actory ssembled Product Selection (standard profile) 440- ➊ V a b c d e a I L O I L Profile 01S 01R 01 05S with Sealing Lip on Right Side 16S S with Sealing Lip on Right Side 03S 02S with Sealing Lip on Right Side 05S with Sealing Lip on Left Side 0804S with Sealing Lip on Left Side 02S with Sealing Lip on Left Side Rubber oot over 01S Rubber oot over 16S b Rail 1212 aluminium for Profile codes -L 1112 zinc coated steel for Profile codes -L 1212P PV black for Profile codes -L 1212PR PV red for Profile codes -L 1212PY PV yellow for Profile codes -L 1214 aluminium with vertical lip for Profile codes -L 1215 aluminium with horizontal lip for Profile codes -L 1216 aluminium deep rail for Profile codes -L 2151 aluminium for Profile codes and O o -Rail (not needed) c able ntrance LT left entrance with 1m cable LT left entrance with 2m cable LT left entrance with 3m cable LT left entrance with 5m cable LT left entrance with m cable RT right entrance with 1m cable RT right entrance with 2m cable RT right entrance with 3m cable RT right entrance with 5m cable RT right entrance with m cable ST straight entrance with 1m cable ST straight entrance with 2m cable L O P Q R S T I L O P Q R S T U V 5 digit number d (continued) able ntrance RT right entrance with m cable ST straight entrance with 1m cable ST straight entrance with 2m cable ST straight entrance with 3m cable ST straight entrance with 5m cable ST straight entrance with m cable UR entrance with 1m cable UR entrance with 2m cable UR entrance with 3m cable UR entrance with 5m cable UR entrance with m cable ➊ Order controller separately. See page 2-4 for selection details. e Termination LT left exit with 1m cable LT left exit with 2m cable LT left exit with 3m cable LT left exit with 5m cable LT left exit with m cable RT right exit with 1m cable RT right exit with 2m cable RT right exit with 3m cable RT right exit with 5m cable RT right exit with m cable ST straight exit with 1m cable ST straight exit with 2m cable ST straight exit with 3m cable ST straight exit with 5m cable ST straight exit with m cable UR exit with 1m cable UR exit with 2m cable UR exit with 3m cable UR exit with 5m cable UR exit with m cable Parallel Termination 15kΩ Series Termination 6kΩ f Length of dge nter length of edge in mm for example: 50m=50000; 500mm= mm minimum 2-0

8 actory ssembled Product Selection (mini-profile) 440- ➊ I V a b c d e a I Profile 0118S 3.75mm (0.15in) ushion actor lack, ini Profile b Rail 1219 aluminium for Profile code o -Rail (not needed) P R S P R S V 5 digit number Presence Sensing Safety evices c able ntrance ST straight entrance 1m cable ST straight entrance 3m cable ST straight entrance 5m cable UR entrance 1m cable UR entrance 3m cable UR entrance 5m cable ➊ Order controller separately. See page 2-4 for selection details. d Termination ST straight entrance 1m cable ST straight entrance 3m cable ST straight entrance 5m cable UR entrance 1m cable UR entrance 3m cable UR entrance 5m cable Series Termination 8kΩ e Length nter length of edge in mm for example: 50m=50000; 500mm= mm minimum 2-1

9 Presence Sensing Safety evices actory ssembled xamples V Series Termination 6Ω Type 01 Oil Resistant Profile 1250 mm long 440-V01250 Type 112/ luminum Rail This is a single oil resistant profile which is 1250mm long. The edge is terminated with a Series Termination. 1m cable enters straight into the closing cap from a I-rail mounted controller. The profile is mounted on a standard aluminium rail LT able xit 5m Type 01 Oil Resistant Profile 1250mm long ST able ntrance with 1m able Type 1214 luminum Rail with Vertical Lip RT Right and ntrance with 2m able This is a single oil resistant profile which is 1250mm long. The edge is terminated with a 1m cable. 1m cable enters straight into the closing cap. The profile is mounted on a standard aluminium rail. control unit is not included. This edge is intended to be used in series with another length of edge which has a terminating resistor. V Series Termination 6Ω Type 05S Profile with Sealing Lip 490mm long 440-V00490 Type 1214 luminum Rail with Vertical Lip RT Right and ntrance with 3m able ote orientation of sealing lip to cable entrance This is single profile has a sealing lip and is 490mm long. The profile is terminated with a Series Termination. 3m cable enters into the right hand side of the closing cap from a plastic surface mounted controller. The profile is mounted on an aluminium rail with a vertical lip for ease of mounting. The orientation of the sealing lip to the vertical lip can be reversed by the user by sliding the profile out of the Rail, rotating the Rail 180 and then re-inserting the profile back into the Rail. 440-U03560 Type 1215 luminum Rail with orizontal Lip U Parallel Termination 15Ω Type 01R Profile 3560mm long LT ntrance with 3m able This is a red-coloured single profile which is 3560mm long. This profile is part of a parallel profile system, for ease of mounting, as it is terminated with a Parallel Termination. 3m cable enters into the left side of the closing cap from a plastic surface mount controller. The profile is mounted on an aluminium Rail with a horizontal lip for ease of mounting. The horizontal lip can be reversed by the user by sliding the profile out of the Rail, rotating the Rail and then re-inserting the profile back into the Rail. separate catalogue number must be entered for the other profile. 2-2

10 This datasheet has been downloaded from: ree ownload aily Updated atabase 0% ree atasheet Search Site 0% ree I Replacement Search Site onvenient lectronic ictionary ast Search System ll atasheets annot e odified Without Permission opyright ach anufacturing ompany

Plok. Rapid Mating Multi-Pin Industrial Connector. Amphenol Industrial Sine Systems * Pyle Connectors Corporation

Plok. Rapid Mating Multi-Pin Industrial Connector. Amphenol Industrial Sine Systems * Pyle Connectors Corporation - Plok Rapid Mating Multi-Pin Industrial onnector mphenol Industrial Sine Systems * Pyle onnectors orporation eatures and enefits Rapid mate spring loaded, push to mate, pull to unmate coupling system

More information

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators Page 1 of 6 TI-P510-01 H Issue 5 IP2, IP2 and IP2D ISO 9001 Spirax-Monnier International ompressed ir Filter/ Regulators ert. No. LRQ 0963008 Description The IP range of Spirax-Monnier international compressed

More information

OPTIONS. Mounting ACCESSORIES FLEXAC.CLIP FLEXAC.EC FLEXAC.P6 FLEXAC.4.C04 FLEXAC.4.C10 PERFORMANCE

OPTIONS. Mounting ACCESSORIES FLEXAC.CLIP FLEXAC.EC FLEXAC.P6 FLEXAC.4.C04 FLEXAC.4.C10 PERFORMANCE FLEX 4 FLEX features driver-less LE technology R9 Values of 60+ Optically clear thermoplastic coating rated for IP65, interior or exterior This product can run up to 100 ft from a single feed with uniform

More information

CABLE CONNECTORS CABLE CONNECTORS

CABLE CONNECTORS CABLE CONNECTORS Terminal blocks Terminal blocks E-loks... 4 Multipolar terminal strips... 49 Protected distribution terminals E-Rail... 50 Preinsulated terminals Preinsulated copper terminals... 53 Preinsulated end-sleeve

More information

ISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4

ISO Sub-bases. Port sizes G 1 /4 - G1 and 1 /4NPT - 1 /2NPT. Sub-bases tovdma specification, for ISO sizes #1, #2, #3 and #4 Port sizes 1 / - 1 and 1 /NPT - 1 /NPT Sub-bases tovd 3 specification, for ISO sizes #1, #, #3 and # Universal bases for ISO sizes #1 and #, side and bottom ported Technical Data edium: See individual

More information

Multiple Connection Manifolds

Multiple Connection Manifolds ultiple onnection anifolds PNUAYN, IN. atalog 2400 Phone 763-559-0177 ax 763-559-0547 eatures l 2 to 10 stations l Inline anifolds, 90 anifolds, ual Air, unction locks and Terminal locks l ustom designs

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax)

Teledyne Oil & Gas North Williamson Blvd. Daytona Beach, FL USA (phone) (fax) PER CO # 33537 Approved By: M. Bartell Originator: Checked By: S. Jackson B. Cornelius 1 of 8 ODN-084-23 23 TITLE: Installation and Operation Manual for Dry- Teledyne Oil & Gas 1026 North Williamson Blvd.

More information

Radial Leaded > RGEF Series. Description. Features. Applications

Radial Leaded > RGEF Series. Description. Features. Applications PolySwitch Resettable PPTs RG Series RoHS escription ittelfuse PolySwitch radial-leaded devices represent the most comprehensive and complete set of PPT products available in the industry today. RG series

More information

IN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4)

IN-LINE CHECK VALVES CIT-02 / 03 / 06 / 10 (1/4,3/8,3/4,1-1/4) RIGHT ANGLE CHECK VALVES CRT / CRG-03 / 06 / 10 (3/8,3/4,1-1/4) IN-LIN HK VLVS IT- / 3 / / (/,3/8,3/,-/) RIGHT NGL HK VLVS RT / RG-3 / / (3/8,3/,-/) Up to 5 MPa (33 PSI), 3 L/min (33 U.S.GPM) Pub. - IRTIONL ONTROLS These valves allow free flow in one direction and

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

COMMERCIAL. Resilent Seated Butterfly Submittal/Technical. Technical Specifications. Application COMMERCIAL. Service

COMMERCIAL. Resilent Seated Butterfly Submittal/Technical. Technical Specifications. Application COMMERCIAL. Service OMMRIL Resilent Seated utterfly Submittal/Technical pplication ray s NY and series resilient seated butterfly valves set the design standard for quality, reliability and long life in a wide variety of

More information

Page. Page AFCO-Rail Order Guide. Level Rail - Balusters. Glass Rail Fixed Stairs - Balusters. Cable Rise & Run Chart Adj. Stairs - Balusters

Page. Page AFCO-Rail Order Guide. Level Rail - Balusters. Glass Rail Fixed Stairs - Balusters. Cable Rise & Run Chart Adj. Stairs - Balusters 2018 O-Rail Page Page Level Rail - alusters 2 lass Rail 6 ixed Stairs - alusters 3 able 7 Rise & Run hart 4 8 dj. Stairs - alusters 5 Level Rail - alusters 110 Series 2-3/4 Lengths: 4, 6, 8 & 10 200 Series

More information

Sealed Systems Altecnic Ltd - Caleffi group. Sealed Systems. Heating vessel sizing guide

Sealed Systems Altecnic Ltd - Caleffi group. Sealed Systems. Heating vessel sizing guide 1.25 Sealed Systems Sealed Systems Sealed primary central heating systems are the most commonly used form of heating system throughout Europe and the rest of the developed world. Sealed central heating

More information

Weatherproof Products

Weatherproof Products Red ot Iberville arlon Weatherproof Products S oxes and overs pplications : S boxes are S approved for wet locations S device boxes are installed in applications that require a rugged unit to accept wiring

More information

Bollard Post, Model R-8902

Bollard Post, Model R-8902 ollard Post, Model R-80 Removable Receiver with Lid (for detail, see sheet of ) Removable Receiver with hain (for detail, see sheet of ) Fixed Embedded Mount (for detail, see sheet of ) Flanged Surface

More information

XML Electromechanical Pressure Switches

XML Electromechanical Pressure Switches Selection Guide Industrial Switches Type of installation ontrol circuits Applications Media controlled Type of operation Air, water, hydraulic oils, corrosive fluids, viscous products Fixed differential:

More information

Bladder Accumulators. General Information. Bladder Accumulators. Introduction. Accumulator Function. Why use a Bladder Accumulator?

Bladder Accumulators. General Information. Bladder Accumulators. Introduction. Accumulator Function. Why use a Bladder Accumulator? General Information Introduction Accumulator unction Bladder accumulators provide a means of regulating the performance of a hydraulic system. The design of the Stauff bladder accumulator makes use of

More information

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS

AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS DESIGNED TO HOLD THE WEIGHT FOR ELECTRICAL CABLE AS IT HANGS IN VERTICAL, SLOPING OR HORIZONTAL POSITIONS. EASILY INSTALLED AND REMOVED USING NO

More information

High-performance submersible pressure transmitter For level measurement Model LH-10

High-performance submersible pressure transmitter For level measurement Model LH-10 Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well

More information

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L.

Cable entries. Contents. Cable entries. Cable entries Introduction L.2 L.1. Standard cable glands - Plastic L.5. Standard cable glands - Brass L. Contents Introduction.2 Standard cable glands - Plastic.5 Standard cable glands - Brass.7 EMC cable glands.14 Standard cable glands - Stainless steel.16 Cable glands for Ex applications - Brass.17 Adaptors.18

More information

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing

More information

Installation and Operation Instruction Manual

Installation and Operation Instruction Manual Installation and Operation Instruction Manual Toggle Lok Anchor - Model #7442 Portable Concrete Anchorage Connector ANSI Z359.1 5,000 lbs / 22.24 kn FallTech, Inc 1306 Alameda Street Compton, CA 90221

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators L ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification

More information

Electrical Sensing Edges

Electrical Sensing Edges sensing the future Electrical Sensing Edges Electrical sensing edges for safeguarding machinery & robots, automatic doors & gates, and public transportation Reliable, proven, long lasting Wide variety

More information

Liquid Level Controls

Liquid Level Controls Series RS High Pressure Sensors & Probes For onductance ctuated ontrols Series RS Sensors Series-RS-X-BR-: NM 4X nclosure For sophisticated multi-level control in tanks, boilers and hydronic systems Remote

More information

Size 10 (D05) p max 320 bar (4600 PSI) Technical Features. Technical Data. Port dimensions ZB10A(B) SMT_0019 ZB K -

Size 10 (D05) p max 320 bar (4600 PSI) Technical Features. Technical Data. Port dimensions ZB10A(B) SMT_0019 ZB K - ase late with with ressure Relief Valve for Serial lates ssemblies Z0 Size 0 (D05) p max 320 bar (4600 SI) echnical Features ank cover mounted base manifold for hydraulic power packs which require one

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

AIR RELEASE VALVES APPLICATIONS BENEFITS. Fast and Easy Installation. High Performance Materials. Complete Security

AIR RELEASE VALVES APPLICATIONS BENEFITS. Fast and Easy Installation. High Performance Materials. Complete Security AI ELEASE VALVES Australian made, Philmac air release valve offers solutions to the agricultural and irrigation industry by providing an economic and reliable solution for removing air from a pipeline.

More information

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual

Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual Fiber Optic Lighted Bubbler Spillway Pot (DLP-45) Installation Manual 27.75 23.75 25.50 20.75 Specifications: 8-13 GPM 100 strand fiber - Bubbler 75 strand fiber - Spillway Light Bar 45 ft. fiber tail

More information

Level transmitter LT 100

Level transmitter LT 100 KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Valves ISO 5599/1 ISO 1, 5/2-5/3, electrically operated, with CNOMO pilot

Valves ISO 5599/1 ISO 1, 5/2-5/3, electrically operated, with CNOMO pilot ISO 1, - 5/3, electrically operated, with CNOMO pilot Executions 0300 ISO1E50 NOTE: FOR VALVES WITH PILOT IN LINE SEE PAGE.111.1 Technical data 03030 ISO1E51 03037 ISO1E5 03031 ISO1E70 0303 ISO1E71 03043

More information

Import Bike Rack OEM INSTALLATION MANUAL

Import Bike Rack OEM INSTALLATION MANUAL Import ike Rack OEM INSTLLTION MNUL TLE OF ONTENTS System Information 2 Safety Information 2 Resources Required 3 Preparation 3 Under umper ttachment 3 Over umper ttachment 3 Installation 3 Under umper

More information

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal

More information

Instruction Sheet. CP2000: 2000 lb Cable Puller IMPORTANT RECEIVING INSTRUCTIONS SAFETY ISSUES

Instruction Sheet. CP2000: 2000 lb Cable Puller IMPORTANT RECEIVING INSTRUCTIONS SAFETY ISSUES Instruction Sheet CP2000: 2000 lb Cable Puller RPS-0148 07/02 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. If shipping damage is found, notify carrier at once.

More information

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR 05.0046U SERIAL No 20 TYPE SX Ex e II C Gb Ex tb IIIC Db IP6* IECEx SIR

More information

Mass Flow Meter (MFM) for gases

Mass Flow Meter (MFM) for gases Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version

More information

Pegasus Series Amphenol Pcd

Pegasus Series Amphenol Pcd Pegasus Series Amphenol Pcd Amphenol Pcd is one of the world s leading suppliers of interconnect products for Military, Commercial Aerospace and Industrial applications. Located north of Boston in Beverly,

More information

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar single stage pumps M/5811 Very high induced air capacity % lower air consumption than comparable single stage units No wearing parts Compatible with a wide range of line contaminants llows direct connection

More information

Electro-hydraulic Proportional Flow and Direction Control Valve

Electro-hydraulic Proportional Flow and Direction Control Valve lectro-hydraulic control valve his valve uses a D solenoid in a traditional 4- way solenoid valve to create a solenoid valve capable of both direction switching and highspeed control. he lineup consists

More information

VALVES SECTION INDEX. Low Pressure 2-Way Ball Valve. Low Pressure 3-Way Ball Valve. Mini Ball Valve 4. Locking and Twin Handles

VALVES SECTION INDEX. Low Pressure 2-Way Ball Valve. Low Pressure 3-Way Ball Valve. Mini Ball Valve 4. Locking and Twin Handles Low Pressure 2-Way Ball Valve Low Pressure 3-Way Ball Valve Mini Ball Valve 4 2 3 VLVES SECTO EX Locking and Twin Handles 1 1 2 3 4 6 7 89 VLVES 2-WY VLVES LPBV-2W 2-WY FULL BORE LOW PRESSURE BLL VLVE

More information

Pneumatic valve islands

Pneumatic valve islands Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented

More information

General Specifications

General Specifications General Specifications DOG Optical Dissolved Oxygen Sensor GENERA DOG optical dissolved oxygen sensor is designed for using in water treatment plants such as sewage treatment works and effl uent activated

More information

VCO O-ring Face Se al Fit tings

VCO O-ring Face Se al Fit tings www.swagelok.com O-ring Face Se al Fit tings /8 to sizes 36 or 36L stainless steel, NPT, S thread, and weld connections 2 O-ring Face Seal Fittings ontents Features........................................

More information

Superior Contact Stability Closed-down design of each contact cavity in the insulator support each contact, minimizes contact splaying.

Superior Contact Stability Closed-down design of each contact cavity in the insulator support each contact, minimizes contact splaying. /345* I--5015 ear elease onnectors ircular tandard ircular igh nvironmental onnectors hese connectors are available for many applications, from commercial/industrial and mass transportation systems to

More information

VALVES ISO 5599/1, SERIES IPV-ISV

VALVES ISO 5599/1, SERIES IPV-ISV VALVES ISO 99/1, SERIES IPV-ISV The assembly surface dimensions of ISO1 and ISO2 valves are to ISO99-1. They are available in the -way versions with 2 and 3 positions and with pneumatic or solenoid actuation.

More information

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1. Thin pressure gauge G401-W Series Thin, compact design ideal for incorporating devices. Suitable for filter regulator, regulator, and pressure switch (P4000-W). onnection: O ring seal, set screw G401-W

More information

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0 ir line equipment P1H, PTH Filter/Regulator- Lubricator Combination Units 07 Series Compact design Filter removes liquids and solid particles down to 5 µm Push to lock adjusting knob with tamper resistant

More information

Cable Glands. Special Applications. RoHS Compliance. Plastic & Metal Cable Glands Adapters Reducers & Enlargers Grommets & Accessories

Cable Glands. Special Applications. RoHS Compliance. Plastic & Metal Cable Glands Adapters Reducers & Enlargers Grommets & Accessories able Glands RoHS ompliance Plastic & Metal able Glands dapters Reducers & Enlargers Grommets & ccessories L File #: E363825 cable gland is a device that allows the user to pass a cable, wire or tube into

More information

SEALED CONNECTORS FOR THE LIMIT SWITCHES

SEALED CONNECTORS FOR THE LIMIT SWITCHES SEALED CONNECTORS FOR THE LIMIT SWITCHES LIST OF MODELS / Sealed connectors are used at the cable-connecting section of limit switches. Type and appearance Materials Features Target market Applications

More information

BALL STOP INSTALLTION GUIDE

BALL STOP INSTALLTION GUIDE BALL STOP INSTALLTION GUIDE GROUND SLEEVE INSTALLATION: 1. Locate the exact location of the ground sleeve. NOTE: Maximum recommended pole spacing is 20 feet on center. 2. Excavate the pole footing; refer

More information

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup.

SERIES 2 RAMP OWNER S MANUAL TOOLS REQUIRED: BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup. SERIES 2 RAMP OWNER S MANUAL BEFORE YOU BEGIN... Read and understand these instructions before beginning a ramp setup. Use caution and care for your back when lifting, pushing, pulling, folding or unfolding

More information

VALVES SECTION INDEX. Click on the Items Below or the Pictures to be Taken to That Page. Low Pressure 2-Way Ball Valve. Low Pressure 3-Way Ball Valve

VALVES SECTION INDEX. Click on the Items Below or the Pictures to be Taken to That Page. Low Pressure 2-Way Ball Valve. Low Pressure 3-Way Ball Valve Click on the tems Below or the Pictures to be Taken to That Page Low Pressure 2-Way Ball Valve Low Pressure 3-Way Ball Valve Mini Ball Valve 4 2 3 VLVES SECTO EX Locking and Twin Handles Rev. B 1 1 2 3

More information

Products no longer available

Products no longer available Technical ata sheet R7..R Open-close ball valves, 3-way, with flange PN 6 for open an close col an warm water systems for switching functions on the water sie an 2-point controls in air-hanling an heating

More information

RECTANGULAR CONNECTORS

RECTANGULAR CONNECTORS RETNGULR ONNETORS FN360 Series FN-365P FN-365J FN-364P FN-364P FN-364J FN-364J FN-365P FN-365J FN-364P FN-364J FN-362J FN-363J FN-365P FN-367J FN-365P FN-364P FN-361P With type cover FN-365J FN-364P With

More information

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM

WIND CLIPPER KTS ILLUM SCALE INC DEC CLIPPER WIND SYSTEM CLIPPER WIND KTS ILLUM SCALE DEC INC CLIPPER WIND SYSTEM TABLE OF CONTENTS INTRODUCTION PRE-TEST OF INSTRUMENT INSTALLING THE MASTHEAD SENSOR UNIT INSTALLING THE DISPLAY NORMAL OPERATION CHANGING THE

More information

RG2 Gripper Datasheet Version 1.6

RG2 Gripper Datasheet Version 1.6 RG2 Gripper Datasheet Version 1.6 The RG2 gripper is a flexible electric gripper specially designed for robots from Universal Robots. The long stroke allows the gripper to handle a variety of object sizes.

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B

Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B Side-of-Pole Mount for 1 Module (SPM1) For Module Types A & B ASSEMBLY INSTRUCTIONS step-by-step assembly and installation Version 1, Rev A PCN 080311-2 SP3363-1 Side-of-Pole Mount for 1 Module (SPM1)

More information

3M Telecommunications Solutions for Networks. Quante QSA (= LSA plus) System Catalogue. Innovation

3M Telecommunications Solutions for Networks. Quante QSA (= LSA plus) System Catalogue. Innovation 3M Telecommunications Solutions for Networks Quante QSA (= LSA plus) System Catalogue Innovation IDC Modules Overview 3M Quante Cross Connect System QSA QSA Series 1 Connection modules for screw fixing

More information

Industrial Compression Style Fittings

Industrial Compression Style Fittings Industrial Compression Style Fittings Compression Fittings Compress-lign Fittings rass etric Compression oly-tite Fittings i-uty Fittings arker annifin Corporation Fluid System Connectors Otsego, I Industrial

More information

Zelio Relays RSL Slim Interface Plug-In Relays

Zelio Relays RSL Slim Interface Plug-In Relays Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3

More information

250 (9.84) 170 (6.69) 225 (8.85) 75 (2.95) 300 (11.81)

250 (9.84) 170 (6.69) 225 (8.85) 75 (2.95) 300 (11.81) Air bellows, single acting Ø... / inch Suitable for applications on rail vehicels Almost frictionless operation No maintenance or lubrication Weather/corrosion resistant metal parts Approvals for fire

More information

PROPORTIONAL PRECISION PRESSURE REGULATOR REGTRONIC SERIES

PROPORTIONAL PRECISION PRESSURE REGULATOR REGTRONIC SERIES PROPORTIONL PREISION PRESSURE REGULTOR REGTRONI SERIES Proportional pressure regulators series REGTRONI have the job of precisely regulating the pressure in a system, the variables depending on the input

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

32374 R. Jazowski 4/4/ D. W. Mudge G. Sivik 1 of 8 ODN TITLE: Installation & Operation Manual for Nautilus G2 Connectors

32374 R. Jazowski 4/4/ D. W. Mudge G. Sivik 1 of 8 ODN TITLE: Installation & Operation Manual for Nautilus G2 Connectors PER CO # Approved By: 32374 R. Jazowski Originator: Checked By: W. Mudge G. Sivik 1 of 8 ODN-342-23 23 TITLE: Installation & Operation Manual for Nautilus Teledyne Oil & Gas 1026 North Williamson Blvd.

More information

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

TEK-SUB 4800B. Submersible Level Transmitter.   Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL Technology Solutions TEK-SUB 4800B Submersible Level Transmitter LEVEL Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Sub 4800B Submersible Level Transmitter

More information

2-90. General 1-Principles 2-Safety Mats 3-Safety Switches 4-Operator. Interface. 5-Logic. Presence Sensing Safety Devices MatGuard Mats Overview

2-90. General 1-Principles 2-Safety Mats 3-Safety Switches 4-Operator. Interface. 5-Logic. Presence Sensing Safety Devices MatGuard Mats Overview Overview 1-Principles 2-Safety ats 3-Safety Switches 4-Operator atguard consists of a number of interconnecting pressuresensitive safety mats and a monitoring control unit that provide a system for area

More information

Spare parts list ( ) Spare parts list HD 2.3/14 C Ed Food

Spare parts list ( ) Spare parts list HD 2.3/14 C Ed Food Spare parts list (5.972-564.0) Spare parts list HD 2.3/14 C Ed Food 05.08.2013 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HD 2.3/14 C Ed Food (5.972-564.0)... 6 10 Housing

More information

VEP-PSERIES INTERCHANGE > Stucchi VEP profile

VEP-PSERIES INTERCHANGE > Stucchi VEP profile VPPSRIS INRHAN > Stucchi VP profile HNIAL AURS AN OPIONS Interchange Stucchi VP profile Sealing description Nitrile NR onnection system Screw SUHI SOLUIONS Available sizes Material /treatment Available

More information

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm

Inductive Linear Displacement Transducers Model IW 260 Measuring strokes: 80 mm, 170 mm, 240 mm, 360 mm Inductive Linear Displacement Transducers Model IW 260 Measuring strokes 80, 170, 240, 360 Document no. IW 100 HE Date 1.07.201 Contactless, robust sensor system Infinite resolution, no hysteresis Calibrated

More information

INSTRUCTION MANUAL. January 23, 2003, Revision 0

INSTRUCTION MANUAL. January 23, 2003, Revision 0 INSTRUCTION MANUAL Model 810A In-Vitro Test Apparatus for 310B Muscle Lever January 23, 2003, Revision 0 Copyright 2003 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora,

More information

B2KL: 6-way ball valve with male thread, PN 16

B2KL: 6-way ball valve with male thread, PN 16 Product data sheet 3.1 58.001 K: 6-way ball valve with male thread, PN 16 How energy efficiency is improved fficiency means precise control and low actuating forces eatures 6-way ball valve for changeover

More information

PARTICULATE FILTER/REGULATOR

PARTICULATE FILTER/REGULATOR PRTICULTE FILTER/REGULTOR High flow with a wide range of adjustable output pressure ranges Optional low profile integrated gauge, Optional extended temperature range of -40 C to +80 C Threaded ports allow

More information

Viking Xtreme Manual Valves Air Control Valves

Viking Xtreme Manual Valves Air Control Valves atalog 0697 Viking Xtreme anual Valves ir ontrol Valves The Viking Xtreme anual valve range is robust, versatile and combines high performance with compact installation dimensions. The valves rugged lever

More information

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1. > Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to

More information

Hoisting Equipment Cable puller & Accessories

Hoisting Equipment Cable puller & Accessories Yale hoists and trolleys are not ed for Cable puller model Yaletrac Pulling force 800-3200 It has a light weight, compact, high tensile aluminium alloy housing with a large flat bottom surface for increased

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases

Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases Mass Flow Controller (MFC)/ Mass Flow Meter (MFM) for gases Nominal flow ranges from l N /min up to l N /min High accuracy and repeatability Communication via standard signals or Industrial Ethernet Electromagnetic

More information

HERZ-Motorised flow controler

HERZ-Motorised flow controler HERZ-Motorised flow controler Control and regulating valve Data sheet 46, Issue 214 Dimensions in mm 4 close dimension 9,35 M DN G H1 H2 H2 + Actuator B1 B2 1 2 M 1 46 11 15 3/4 G 66 59 73 134 49 63 48

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Conveyor Wear Bed T- Chain Guides and Wear Beds Valu Guide rail can be used as a guide or wear strip for wide

More information

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC www.atos.com Table -2/E Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification TEX, IEEx, E valve body spool ex-proof solenoid ex-proof inductive

More information

Spare parts list. ( ) Spare parts list HD 3.0/20 C Ea

Spare parts list. ( ) Spare parts list HD 3.0/20 C Ea Spare parts list (5.972-551.0) Spare parts list HD 3.0/20 C Ea 24.06.2016 www.kaercher.com EN Page 2 / 51 Page 3 / 51 Page 4 / 51 Table of contents Order instructions Spare parts list HD 3.0/20 C Ea (5.972-551.0)

More information

APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL

APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL ROV & AUV PRODUCTS GRE (Glass Reinforced Epoxy) CS-MS 55 & 66 SERIES MINI-CON HUMMER GLOBE-CON ALL-WET

More information

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) Stainless steel and plastic enclosures for use in potentially explosive environments R Rittal system partners Perfect

More information

F13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS

F13.11 PARALLEL HINGES F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS F13 PROJECT-OUT WINDOWS AND TOP HUNG WINDOWS F13.11 01.06.2018 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. General...F13.11.03

More information

Saf-T Vent EZ Seal Plus

Saf-T Vent EZ Seal Plus Technical and Dimensional Data Saf-T Vent EZ Seal Plus Single Wall L 29-4 Stainless Steel Special Gas Vent Tested and Listed to UL 1738/UL S636 by Underwriters Laboratories, Inc 5030 orporate Exchange

More information

Spare parts list. ( ) Spare parts list HD 3.0/20 C Ea

Spare parts list. ( ) Spare parts list HD 3.0/20 C Ea Spare parts list (5.972-551.0) Spare parts list HD 3.0/20 C Ea 20.04.2016 www.kaercher.com EN Table of contents Order instructions Spare parts list HD 3.0/20 C Ea (5.972-551.0) 10 Housing 20 Pump set 21

More information

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No

Installation Instructions MODEL VSTI-A020 Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Versa Steel Inc. Guide Cables No Tank Indicator Installation Model: VSTI-A020, Stainless Reverse Read System Guide Cables No Guide Cables 1 August 4, 2011 Assembly Instructions: (Shown with a 2 board, 12 ft kit) ITEM NO. PART NUMBER DESCRIPTION

More information

MultiWoody design Mario Cucinella

MultiWoody design Mario Cucinella design Mario Cucinella 9000 7000 5000 MaxiWoody ø 260 MaxiWoody ø 315 MaxiWoody ø 380 www.iguzzini.com 473 Compositions Flanges and supports for 2 floodligts single flange double flange for 3 floodligts

More information

Products no longer available

Products no longer available Technical ata sheet R7..R haracterize control valves, 3-way, with flange PN 6 for open an close col an warm water systems for moulating control on the water sie of air-hanling an heating systems air bubble-tight

More information

Ramp Hand-railing System. Complies with Building Regulations. Lockinex. ea i, ea u i

Ramp Hand-railing System. Complies with Building Regulations. Lockinex. ea i, ea u i Ramp Hand-railing System Complies with Building Regulations Lockinex ea i, ea u i INTRODUCTION COMPOSITION, MANUFACTURE Handrails to ramps must comply to current building regulations. The Lockinex system

More information

GM-7000 Series CE Approved Gas Control Valve

GM-7000 Series CE Approved Gas Control Valve Installation Instructions GM-7000 Issue Date November 9, 2012 GM-7000 Series CE Approved Gas Control Valve Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing

More information

GA24 Technical Datasheet

GA24 Technical Datasheet GA24 Technical Datasheet Variable-area flowmeter Sturdy construction for several applications Local indication without auxiliary power Replaceable mounting parts KROHNE CONTENTS GA24 1 Product features

More information

LCI Party Deck OWNER'S MANUAL

LCI Party Deck OWNER'S MANUAL LCI Party Deck OWNER'S MANUAL Introduction Lippert Components Party Decks are designed to help transform the ramp door of a coach into a comfortable, additional living space. The LCI Party Deck takes previously

More information

Installation and Maintenance Manual. Compact Medical Gas Outlets

Installation and Maintenance Manual. Compact Medical Gas Outlets Installation and Maintenance Manual Compact Medical Gas Outlets Contents Product Description 3 Cleaning and Lubricating 4 Inspection and Testing 4 Installation and Dimensions 5-6 Compact Outlet Indexing

More information

SATURNSERIES INTERCHANGE > ISO (for the couplings)

SATURNSERIES INTERCHANGE > ISO (for the couplings) NTERHANE > (for the couplings) TEHNAL FEATURES AND OPTONS nterchange (for the couplings) Sealing description Nitrile NR onnection system Push Available sizes Material /treatment Available threads from

More information