Cartridge Valves Technical Information Proportional Valves Quick Reference

Size: px
Start display at page:

Download "Cartridge Valves Technical Information Proportional Valves Quick Reference"

Transcription

1 Quick Reference Proportional Directional Model No. Description Flow* Pressure Page PSV-3- SDC- Proportional directional l/min 5. valve [6 ] [36 ] S 3 S Quick reference Proportional Directional Model No. Description Flow* Pressure Page 3.3 l/min 3.3 valve [8 ] [6 ] PDCV5-3Z ISO D5 6 l/min 3. [6 ] [6 ] A B PDCV3-3Z ISO D3 Proportional directional P T Proportional Directional Model No. Description Flow* Pressure Page PSV-3-5 SDC- Proportional directional l/min 5.5 valve [6 ] [36 ] S 3 S Proportional Directional Model No. Description Flow* Pressure Page PDCV3-3Y ISO D3 Proportional directional 3.3 l/min 3.6 valve [8 ] [6 ] A B PDCV5-3Y ISO D5 6 l/min [6 ] 3 [6 ].7 P T Proportional Flow Controls Model No. Description Flow* Pressure Page CP58-PNC SDC8- Proportional Flow Control l/min.8 Valve, Non-Compensated, [3 ] [3 ] Normally Closed PSV-NC SDC- l/min [ ] PSV-NC SDC- 8 l/min [ ] PSV6-NC SDC6- l/min [6 ] 6 [377 ] 6 [377 ] 6 [377 ] * Flow ratings are based on a pressure drop of 7 [ ] unless otherwise noted. They are for comparison purposes only L588 Rev DA June.

2 Quick Reference Quick reference Proportional Flow Controls Model No. Description Flow* Pressure Page PSVP-NCR SDC- Proportional Flow Control 55 l/min 6. Valve, Non-Compensated, [ ] [377 ] PSVP-NCR SDC- Normally Closed, Poppet 7 l/min 6.3 Type [8 ] [377 ] PSVP6-NCR SDC6-9 l/min [ ] 6 [377 ]. Proportional Flow Controls Model No. Description Flow* Pressure Page CP58-PNO SDC8- Proportional Flow Control l/min.5 Valve, Non-Compensated, [3 ] [3 ] PSV-NO SDC- Normally Open 5 l/min 6.6 [ ] [377 ] PSV-NO SDC- l/min [6 ] 6 [377 ].7 Proportional Flow Controls Model No. Description Flow* Pressure Page PSVP-NOR SDC- Proportional Flow Control 5 l/min 6.8 PSVP-NOR SDC- Valve, Non-Compensated, Normally Open, Poppet [ ] 7 l/min [377 ] 6.9 Type [8 ] [377 ] PSVP6-NOR SDC6-8 l/min [ ] 6 [377 ].3 Proportional Flow Controls Model No. Description Flow* Pressure Page PFC-RC SDC- Proportional Flow 3 l/min 6.3 Control Valve, Pressure [8 ] [377 ] PFC-RC SDC- Compensated, Restrictive 65 l/min 6.3 Type, Normally Closed [7 ] [377 ] P PFC6-RC SDC6-9 l/min [ ] 6 [377 ].33 Proportional Flow Controls Model No. Description Flow* Pressure Page PFC-RO SDC- Proportional Flow 3 l/min 6.3 Control Valve, Pressure [8 ] [377 ] PFC-RO SDC- Compensated, Restrictive 6 l/min 6.35 Type, Normally Open [6 ] [377 ] P PFC6-RO SDC6-85 l/min [ ] 6 [377 ].36. 5L588 Rev DA June * Flow ratings are based on a pressure drop of 7 [ ] unless otherwise noted. They are for comparison purposes only.

3 Quick Reference Proportional Flow Controls Model No. Description Flow* Pressure Page PFC-PC SDC-3 Proportional Flow l/min 6.37 PFC-PC SDC-3 Control Valve, Pressure Compensated, Priority Type, Normally Closed [ ] 65 l/min [7 ] [377 ] 6 [377 ].38 PFC6-PC SDC l/min [ ] 6 [377 ] Proportional Flow Controls Model No. Description Flow* Pressure Page PFC-PO SDC-3 Proportional Flow 35 l/min 6. Control Valve, Pressure [9 ] [377 ] PFC-PO SDC- Compensated, Priority 7 l/min 6. Type, Normally Open [8 ] [377 ] P PFC6-PO SDC6-3 9 l/min [ ] 6 [377 ].39. Quick reference Proportional Pressure Reducing Model No. Description Flow* Pressure Page CP558- SDC8-3 Proportional Pressure l/min 3.3 Reducing Valve, [ ] [5 ] Direct Acting, Normally Open 3 Proportional Pressure Reducing Model No. Description Flow* Pressure Page XRP SDC- Proportional Pressure 5 l/min 5. Reducing/Relieving Valve, [7 ] [7 ] Piloted, Normally Open 3 P * Flow ratings are based on a pressure drop of 7 [ ] unless otherwise noted. They are for comparison purposes only. 5L588 Rev DA June.3

4 Quick Reference Quick reference Proportional Pressure Reducing Model No. Description Flow* Pressure Page PPR-PAC SDC-3 Proportional Pressure 8 l/min 5.5 Reducing/Relieving Valve, [5 ] [365 ] Piloted, Normally Closed 3 Proportional Pressure Reducing Model No. Description Flow* Pressure Page XRP 6 NCS6/3 Proportional Pressure Reducing/Relieving Valve, Piloted, Normally Open 5 l/min [7 ] 35 [5 ].6 Proportional Pressure Relieving Model No. Description Flow* Pressure Page XMD NCS/ Proportional Pressure 5 l/min 5.7 CP558- SDC8- Reducing Valve, Direct Acting, Normally Open [ ] 8 l/min [ ] [36 ] [3 ].8 Proportional Pressure Relieving Model No. Description Flow* Pressure Page 76 l/min 5.9 Pilot Operated, [ ] [36 ] PRV-POC SDC- Normally Closed 8 l/min 5.5 [8 ] [36 ] PRV-POC SDC- Proportional Relief Valve, Proportional Pressure Relieving Model No. Description Flow* Pressure Page XMP 6 NCS6/ Proportional Relief Valve, Pilot Operated, Normally Open 5 l/min [3 ] 35 [5 ].5. 5L588 Rev DA June * Flow ratings are based on a pressure drop of 7 [ ] unless otherwise noted. They are for comparison purposes only.

5 Application Notes PROPORTIONAL VALVES Proportional, or electro-proportional valves, provide infinitely variable control of flow, pressure, or direction, in response to a electric input signal. There are four basic types of Sauer-Danfoss proportional valves: Flow control valves. Pressure reducing/relieving valves. Pressure relief valves. Directional control valves Application notes F PL+ compliant Sauer-Danfoss solenoid valves are PL+ compliant. PL+ compliance means our valves are directly compatible with the PL+ machine control architecture. Adding solenoid valves to your application using PL+ GUIDE software is as easy as dragand-drop. Software development that used to take months can now be done in just a few hours. For more information on PL+ GUIDE, visit The table below details available GUIDE function blocks for controlling Sauer-Danfoss solenoid valves. GUIDE function blocks Two-way proportional 63 Three-way proportional 6 5L588 Rev DA June.5

6 Application Notes Application notes PROPORTIONAL FLOW CONTROL VALVES Sauer-Danfoss proportional flow control valves are -way, spool-type valves that are directly operated with a proportional electromagnetic solenoid actuator. By controlling electric, these valves create an infinitely variable orifice. Proportional flow control valve These valves are designed to be used with a logic element to provide pressure compensation. Pressure compensation provides two advantages: P8 39. A constant pressure differential is maintained across the proportional valve (variable orifice), which maintains constant flow regardless of changes in operating pressure or load.. A constant pressure differential across the proportional valve limits the flow forces acting on the valve spool. At high flow and pressure, the electromagnetic and spring forces can be insufficient to maintain valve operation without pressure compensation. Typical flow versus pressure drop Pressure drop with compensation without compensation Typical circuits use restrictive-type or priority-type pressure compensators with proportional flow control valves to control speed of a hydraulic motor or cylinder. Proportional flow control valves are available with a variety of flow capabilities (variable orifice sizes). By matching this flow capability to various pressure compensator settings, a wide range of flow vs. control curves can be attained. Flow P3 9E Typical circuit using a proportional valve Restrictive-type circuit Priority-type circuit Out Bypass Out Flow versus.3 [5 ] 6.9 [ ] 3. [5 ] Flow In In P3 3E Current P3 3E Effect of pressure compensator setting.6 5L588 Rev DA June

7 Application Notes PROPORTIONAL PRESSURE REDUCING/ RELIEVING VALVES Proportional pressure reducing/relieving valves are 3-way valves that provide a controlled output pressure as a function of electric, regardless of system pressure or flow (within the valve s limits). Direct acting designs are available for low-flow applications. Direct-acting, proportional, pressure reducing valve Application notes P8 35 Proportional pressure reducing valves have a variety of applications including: Single acting cylinder position control, e.g. combine header height control. Clutch or brake pressure control. Pilot signal to a directional control valve. By slowly ramping the to the proportional valve in this example, a soft-start and soft-stop is attained. Pilot signal to directional control valve A B Clutch pressure control P P3 3E Single-acting cylinder piston control W P P T P3 35E P3 33E High flow proportional pressure reducing valve functions can be created by using a proportional valve to pilot a differential sensing valve; see differential sensing valve application notes for more information. 5L588 Rev DA June.7

8 Application Notes Application notes PROPORTIONAL PRESSURE RELIEF VALVES Proportional pressure relief valves are - way valves that provide a relief pressure as a function of electric. Both normally-open (increasing pressure with increasing ), and normally-closed (decreasing pressure with increasing ) are available. Normally closed versus normally open proportional relief valves The normally-open proportional relief valve is a direct-acting design for low flow applications. High flow normallyopen proportional relief valve functions can be created by using a proportional valve to pilot a differential sensing valve; see differential sensing valve application notes for more information. Pressure Normally-Open Normally-Closed Current P3 36E Normally-open proportional relief valve P T Common applications for normally-open proportional relief valves are: P3 37E Electro-proportional control of system relief pressure; see differential sensing valve application notes for more information. Electro-proportional remote pressure compensator control for open circuit piston pumps (for more information refer to BLN-8 Series 5 Open Circuit Axial Piston Pumps Technical ). Remote pressure compensator pump control B X X M L S L P3 38E.8 5L588 Rev DA June

9 Application Notes PROPORTIONAL PRESSURE RELIEF VALVES (continued) Normally-closed proportional relief valves are available in direct-acting and pilotoperated designs. A direct-acting, normally-closed proportional relief valve is used for low flow applications. For high flow applications, internally pilot-operated cartridges are available. Internally pilot-operated cartridge for high flow applications Application notes P8 35 Common applications for normally-closed proportional relief valves are: Electro-proportional control of system relief pressure or electroproportional remote pressure compensator control for open circuit piston pumps as above, but where system requirements dictate full pressure with no electrical signal. Cooling fan speed control Cooling fan speed control in hydrostatic fan drive systems. (For more information refer to BLN-8 Fan Drives Systems and Components Technical ). P3 ELECTRICAL REQUIREMENTS All Sauer-Danfoss proportional cartridge valves are analog-type valves that control flow or pressure as a function of electric. For this reason, proportional valves should be driven with a -controlled device that will maintain constant output regardless of changes in system voltage, line losses, or temperature. Typically available controlled valve drivers output a pulsewidth-modulated (PWM) square-wave signal. An advantage of a PWM signal is that the dither it provides significantly reduces hysteresis. Sauer-Danfoss recommends using a - Hz dither for best performance. Proportional valve hysteresis Flow or pressure Direct PWM signal Current P3 E Typical performance 5L588 Rev DA June.9

10 Application Notes Application notes TERMS AND DEFINITIONS Analog are controlled by electric, which may be direct (DC) or a PWM signal. Compensator is a hydraulic component that maintains a constant pressure drop across a fixed or variable orifice. Current is the flow of electricity through a conductor or coil, normally measured in amps (A). Steady-state flow in an electrical circuit can be calculated by Ohm s Law, as well as voltage and resistance. Ohm s Law I = V R Current Control is a feature of almost all valve drivers. The output of analog proportional valves is a direct function of. If a valve is controlled with voltage, higher solenoid temperatures, which increase solenoid resistance, will result Current feedback circuit Current in lower valve output. To compensate sensing resistor for this, most valve drivers are designed with feedback circuitry. This means that as solenoid temperature rises Input or as supply voltage and voltage losses change, the and corresponding valve output are maintained. Deadband is the range from zero to the minimum which causes the valve to respond. Solenoid P3 E Digital are extremely fast responding valves that are controlled by a precise on-off signal to produce an average output that is a function of duty cycle. Dither is a ripple signal sent to a solenoid to reduce hysteresis. Dither can be a sine, square, or saw-tooth wave superimposed on a PWM signal or it can be a wave on top of a DC signal. Duty Cycle is the % of time the valve is on divided by total time. is the difference in output for a given input, depending on whether the input is increasing or decreasing. It is normally expressed as a % of the maximum rated output. For example, if a 6 l/min [ ] proportional flow control valve provides 8 l/min [ ] with amp-increasing and 88 l/min [3 ] at ampdecreasing, the hysteresis is: (88-8) = 5% 6 I min is the minimum required for valve response (see deadband). I max is the required for maximum valve output.. 5L588 Rev DA June

11 Application Notes TERMS AND DEFINITIONS (continued) PWM is an acronym for Pulse-Width-Modulation. Most valve drivers use a controlled PWM output to reduce valve hysteresis and to allow control without excessive heat generation. A typical PWM output is a square wave from 8-5 Hz. Ramping is the application of to a solenoid with a linear or non-linear ramp, rather than an instantaneous step. Ramping on and off to a proportional valve provides actuators with soft-starts and soft-stops. Ramps can generally be set or preprogrammed into valve drivers. Resistance is a component s opposition to the flow of electrical, usually measured in ohms (Ω). Resistance depends on the conductivity of the material, as well as size, shape, and temperature. Solenoid resistance can vary greatly with temperature; to compensate for this, -controlled drivers are generally always used with proportional valves. Application notes Threshold is the minimum required for valve response; see deadband. Valve Driver is a generic term for any device that sends a signal to a proportional valve. A valve driver may range from a simple electronic circuit attached to a knob or lever up to a microcontroller with custom software and multiple inputs and outputs. Voltage is the potential for to flow in an electric circuit, usually measured in volts (V). 5L588 Rev DA June.

12 Proportional Directional PSV-3- This is a non-compensated proportional directional control valve. PSV-3- Rated pressure Rated flow at [5 ] Threshold Standard Coil 5 [36 ] l/min [6 ].77 kg [.7 lb] % maximum.5 A ( VDC coil).5 A ( VDC coil).5 A ( VDC coil).8 A ( VDC coil) SDC- M6 6 Watt l/min Operating curves made with circuit having a pressure drop of Bar. 6 cst [ S] hyd.oil@5 C [ F] (S) (S) (S) (S) ( V) ( V) (A).5.5 (A) 6 5 l/min 5 5 Pressure compensation from Inlet to work port at Max 6 cst [ S] hyd.oil@5 C [ F] l/min l/min S 3 S P Bar 3 (Differential pressure) P3 89 mm 9- Nm [6-8 lbf*ft] KIT P/N 73 7mm 5-5 Nm [33-37 lbf*ft] 7/8- UNF A A P B S S T Ø 6.5 [Ø.] COILS NOT SHOWN FOR CLARITY INSTALL O-RINGS () PLCS AS SHOWN 7.5 [5.] 5 [.] 6 [.] P3 8 Coil voltage = No coil = V DC = V DC Coil termination = No connector AJ = Amp junior AS = Amp superseal.5 DE = Deutsch DN = DIN 365 FL = Lead wires SP = Spade PSV-3---DN--B-XX Housing and ports Housing P/N = No Housing No Housing L3B = AL, 3/8 BSP SDC--L-3B LB = AL,/ BSP SDC--L-B 6S = AL, #6 SAE CP--6S 8S = AL, #8 SAE CP--8S Other housings available Seal Kit B = Buna-N 3599 V =Viton 359 Max regulated flow = l/min [3. ] = l/min [5.8 ] P3 86E. 5L588 Rev DA June

13 Proportional Directional PDCV3-3Z This valve is a proportional directional control. Rated pressure 3 [6 ] Rated flow at 3 l/min [8 ] [5 ]. kg [5.9 lb] 6% maximum Threshold.5 A ( VDC coil).5 A ( VDC coil). A ( VDC coil). A ( VDC coil) ISO D3 Standard Coil PD3 Watt Coil nut A B gpm L/min gpm L/min Flow Flow S (33 cst) hyd. F (38 C) at [5 ] pressure drop Code = 3 Code = Current, Amps (with VDC coil) 5 S (33 cst) hyd. F (38 C). A ( V coil).9 A ( V coil). ) A V c ( oil Loop pressure drop (P A B T) P 939E PDCV3-3Z P T P 7E Ø 5.7 [.8] 5.9 [8.5] PDCV3-3Z/5--E-8S Voltage = VDC = VDC Subplate option OMIT = No subplate 8S = Aluminum, #8 SAE ports S8S =Steel, #8 SAE ports Nominal flow rate 5 = 5 L/min [. gpm] 3 = 3 L/min [7.9 gpm] Termination E = DIN 365 E3 = Amp Jr. E8 = Lead wires E = Deutsch E = Dual spade P 7 Seal Kit Seal kit B = Buna-N V = Viton Note :All internal seals are viton Bolt Kit #- Thd M5 Thd P 7E 5L588 Rev DA June.3

14 Proportional Directional PDCV5-3Z This is a non-compensated proportional directional control valve. PDCV5-3Z Rated pressure Rated flow at [5 ] Threshold Standard Coil 3 [6 ] 6 l/min [6 ] 6.6 kg [.6 lb] 6% maximum. A ( VDC coil). A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) ISO D5 PD5 3 Watt flow vs 6 cst [5 S] C [68 F] l/min 8 Nominal flow = 6 l/min flow At (5 ) pressure drop Nominal flow =3 l/min Current, Amps (VDC coil).5 l/min 5 6 pressure drop A B flow 5. Amps Current =. Amps.9 Amps.96 Amps Loop Pressure Drop P A B T P T P 7E P 53E 7 mm [.76 in] 38 mm [.5 in] P 536E PDCV5-3Z/3--E Connector E = DIN 365 E8 =Lead wires E =Deutsch on leads Seal kit B = Buna N V = Viton All internal seals areviton Flow rate 3 = 3 l/min [7.9 ] 6 = 6 l/min [5.8 ] Voltage = VDC = VDC Bolt kit /- Thd M6 Thd 58-8 P3 987E. 5L588 Rev DA June

15 Proportional Directional PSV-3-5 This is a non-compensated proportional directional control valve. Rated pressure Rated flow at [5 ] Threshold Standard Coil 5 [36 ] l/min [6 ].77 kg [.7 lb] % maximum.5 A ( VDC coil).5 A ( VDC coil).5 A ( VDC coil).8 A ( VDC coil) SDC- M6 6 Watt l/min Operating curves made with circuit having a pressure drop of. 6 cst [ S] hyd.oil@5 C [ F] (S) (S) (S) (S) PSV-3-5 ( V) ( V) (A).5 (A) 6 5 l/min 5 5 Pressure compensation from Inlet to work port at max 6 cst [ S] hyd.oil@5 C [ F] l/min l/min S 3 S P Bar 3 (Differential pressure) P3 895E A P B T Ø 6.5 [Ø.] 7.5 [5.] 5 [.] 6 [.] P3 85 Coil voltage = No coil = V DC = V DC Coil termination = No connector AJ = Amp junior AS = Amp superseal.5 DE = Deutsch DN = DIN 365 FL = Lead wires SP= Spade PSV-3-5--DN--B-XX Housing and ports Housing P/N = No Housing No Housing L3B = AL, 3/8 BSP SDC--L-3B LB = AL,/ BSP SDC--L-B 6S = AL, #6 SAE CP--6S 8S = AL, #8 SAE CP--8S Other housings available Seal Kit B = Buna-N 3599 V =Viton 359 Max regulated flow = l/min [3. ] = l/min [5.8 ] P3 87E 5L588 Rev DA June.5

16 Proportional Directional PDCV3-3Y This valve is a proportional directional control. P-DCV3-3Y Rated pressure 3 [6 ] Rated flow at 3 l/min [8 ] [5 ]. kg [5.9 lb] 6% maximum Threshold.5 A ( VDC coil).5 A ( VDC coil). A ( VDC coil). A ( VDC coil) ISO D3 Standard Coil PD3 Watt Coil nut gpm L/min Flow gpm L/min S (33 cst) hyd. F (38 C) at [5 ] pressure drop Code = 3 Code = Current, Amps (with VDC coil) 5 S (33 cst) hyd. F (38 C) A ( V coil) 5.3 Flow 5.9 A ( V coil) A B ) A V c ( oil Loop pressure drop (P A B T) P 939E P T P 7E Ø 5.7 [.8] 5.9 [8.5] PDCV3-3Y/5--E-8S Subplate option OMIT = No subplate 8S = Aluminum, #8 SAE ports S8S =Steel, #8 SAE ports Voltage = VDC = VDC Nominal flow rate 5 = 5 L/min [. gpm] 3 = 3 L/min [7.9 gpm] Termination E = DIN 365 E3 = Amp Jr. E8 = Lead wires E = Deutsch E = Dual spade P 7 Seal Kit Seal kit B = Buna-N V = Viton Note :All internal seals are viton Bolt Kit #- Thd M5 Thd P 73E.6 5L588 Rev DA June

17 Proportional Directional PDCV5-3Y This is a non-compensated proportional directional control valve. Rated pressure Rated flow at [5 ] Threshold Standard Coil 3 [6 ] 6 l/min [6 ] 6.6 kg [.6 lb] 6% maximum. A ( VDC coil). A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) ISO D5 PD5 3 Watt flow vs 6 cst [5 S] C [68 F] l/min 8 Nominal flow = 6 l/min flow At (5 ) pressure drop Nominal flow =3 l/min Current, Amps (VDC coil).5 P-DCV5-3Y l/min 5 6 pressure drop A B flow 5. Amps Current =. Amps.9 Amps.96 Amps P T P 7E loop pressure drop P A B T P 533E 7 mm [.76 in] 38 mm [.5 in] P 536E P-DCV5-3Y/3--E Connector Seal kit E = DIN 365 B = Buna N E8 =Lead wires V = Viton E =Deutsch on leads All internal seals areviton Nominal flow rate 3 = 3 l/min [7.9 ] 6 = 6 l/min [5.8 ] Voltage = VDC = VDC Bolt kit /- Thd M6 Thd 58-8 P3 986E 5L588 Rev DA June.7

18 Proportional Flow Controls CP58-PNC This valve is a non-compensated, normally-closed, proportional flow control. CP58-PNC Rated pressure [3 ] Rated flow at 6 l/min [3 ] [8 ].36 kg [.8 lb] % maximum Threshold.8 A ( VDC coil). A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure differential [3 ] maximum SDC8- Standard Coil M9P Watt Coil nut 738 Flow vs. Current at 5.5 [8 ] pressure drop 33 cst [5 S] C [ F] l/min H 6H H H Current, Amps (with VDC coil) Pressure Drop vs. Flow At Maximum Control Current 33 cst [5 S] C [ F] 7 H 6H 8H P 83 9 L/min P 9E 5 N m MAX. [ lbf in] 7/8 HEX 7-3 N m [-5 lbf ft] 3/-6 UNF COIL NOT SHOWN FOR CLARITY INSTALL O-RING AS SHOWN 86. [3.39] P 7E Seal kits U = Urethane 59 CP58-PNC-U-6S-H--DE Voltage = No coil = VDC = VDC Termination = No connector DE = Deutsch DN = DIN 365 FL = Lead wires AJ = AMP Jr Housing and ports Housing P/N = Cartridge only No Housing S = AL, # SAE CP8--S 6S = AL, #6 SAE CP8--6S B = AL,/ BSP SDC8--DG-B 3B = AL, 3/8 BSP SDC8--DG-3B.8 5L588 Rev DA June Flow code H = 5 l/min [.3 ] at 5.5 [8 ] H = 9 l/min [. ] 6H = l/min [.9 ] 8H = 3 l/min [3. ] P 65E

19 Proportional Flow Controls PSV-NC Rated pressure Maximum flow at [5 ] pressure drop Leakage Threshold Pressure differential Standard Coil This is a normally-closed, direct-acting, spool-type, non-compensated, proportional flowcontrol. Controlled flow is from port to. 6 [377 ] PSV-NC-: l/min [.6 ] PSV-NC-5: 5 l/min [6.6 ] PSV-NC-: l/min [.6 ] cm³/min [5.6 at rated pressure.5 kg [. lb] 5% maximum. A ( VDC coil). A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) [ ] maximum SDC- M9P Watt 8 6 ( V) ( V) 5 l/min 5 3 Operatingcurvesmadewithcircuit havingapressure drop of. 6 cst [ S] hyd.oil@5 C [ F] Pressure drop 6 cst [S] hyd.oil at 5 C [ F].9 (A).8 (A) PSV-NC 7 5 P 83 P l/min. 5 6mm 3-5 Nm [.-3.7bf ft] COIL NUT KIT P/N Nm[33-37 lbf ft] 7/8- UNFA Ø6.5 [Ø.] COIL NOT SHOWN FOR CLARITY 86.8 [3.] 3. [.6] P 833 Max regulated flow =l/min Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ = AMP Jr 5L588 Rev DA June PSV-NC--D-DN-B- Body and Ports =nohousing 6S =Al, #6 SAE 8S =Al, #8 SAE DG3B =Al,3/8 BSP DGB =Al,/ BSP Otherhousing available SealKit B=Buna-Nseals 359 V=Vitonseals 3539 Body Nomenclature No Body CP--6S CP--8S SDC--DG3B SDC--DGB P 835.9

20 Proportional Flow Controls PSV-NC PSV-NC This is a normally-closed, direct-acting, spool-type, non-compensated, proportional flowcontrol. Controlled flow is from port to. Rated pressure 6 [377 ] Maximum flow at PSV-NC-6: 6 l/min [5.85 ] [5 ] PSV-NC-8: 8 l/min [.3 ] Leakage cm³/min [5.6 at rated pressure.76 kg [.68 lb] 5% maximum Threshold.5 A ( VDC coil).5 A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure differential [ ] maximum SDC- Standard Coil DE(35W) 35 Watt 6 8 l/min 8 6 Operatingcurvesmadewithcircuit havingapressure drop of. 6 cst [ S] hyd.oil@5 C [ F] ( V) (A) ( V).6..8 (A) Pressure drop 6 cst [S] hyd.oil at 5 C [ F] 6 P 83 P l/min. 7mm 9- Nm [6-8 lbf*ft] 3mm 68-75Nm[5-55 lbf*ft] -/6- UN Coil Nut P/N Ø3.5 [Ø.] COIL NOT SHOWN FOR CLARITY 9.5 [3.7] 5. [.77] P 8 Maxregulated flow 8 =8l/min Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ =Amp Junior AS =Amp Superseal PSV-NC-8-D-DN-B- Body andports =Nohousing S=Al, #SAE S=Al, #SAE DGB =Al,/ BSP DG6B =Al,3/ BSP Otherhousing available SealKit B=Buna-Nseals V=Viton 3589 P 83 Body Nomencl. No Body CP--S CP--S SDC--DGB SDC--DG6B. 5L588 Rev DA June

21 Proportional Flow Controls PSV6-NC This is a normally-closed, direct-acting, spool-type, non-compensated, proportional flowcontrol. Controlled flow is from port to. Rated pressure Rated flow at [5 ] Leakage Threshold Pressure differential Standard Coil 6 [377 ] l/min [6 ] cm³/min [5.6 at rated pressure.87 kg [.9 lb] 5% maximum.5 A ( VDC coil).5 A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) [ ] maximum SDC6- DE(35W) 35 Watt ( V) ( V) 9 6 l/min 8 6 Operatingcurvesmadewithcircuit havingapressure drop of. 6 cst [ S] hyd.oil@5 C [ F] (A).6..8 (A) Pressure drop 6 cst [S] hyd.oil at 5 C [ F] PSV6-NC 3 P 83 P l/min. 7mm 9- Nm [6-8 lbf*ft] 38mm -36Nm[9- lbf*ft] 5/6- UN Coil Nut P/N Ø37.8 [Ø.9] COIL NOT SHOWN FOR CLARITY 97.3 [3.83] 3.6 [.] 7. [.85] P 88 Maxregulated flow = l/min Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ =Amp Junior AS =Amp Superseal 5L588 Rev DA June PSV6-NC--D-DN-B- Body andports =Nohousing DG6B =Al,3/ BSP DG8B =Al, BSP S=Al, #SAE 6S=Al, #6SAE Otherhousing available SealKit B=Buna-Nseals V=Viton P 85 Body Nomencl. No Body SDC6--DG-6B SDC6--DG-8B CP6--S CP6--6S.

22 Proportional Flow Controls PSVP-NCR PSVP-NCR This is a non-compensated, normally-closed, pilot-operated, poppet-type, proportional flow-control. Controlled flow is from port to. Rated pressure 6 [377 ] Rated flow at 55 l/min [ ] [5 ] Leakage 6 at rated pressure.5 kg [.9 lb] 8% maximum Threshold.8 A ( VDC coil). A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure differential [ ] maximum SDC- Standard Coil M9P Watt OperatingCurves l/min 6 cst [ S] hyd.oil@5 C [ F] ( V) (A) ( V).6..8 (A) Pressuredrop 6 cst [S] hyd.oil at 5 C [ F] 6 8 P l/min. P mm 3-5 Nm [.-3.7bf*ft] COIL NUT KIT P/N Nm[33-37 lbf*ft] 7/8- UNFA Ø6.5 [Ø.] COIL NOT SHOWN FOR CLARITY 7. [.] 3.9 [.6] P 855 Coil voltage = Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ = AMP Jr PSVP-NCR-D-DN-B- Body andports =Nohousing 6S =Al, #6 SAE 8S =Al, #8 SAE DG3B =Al,3/8 BSP DGB =Al,/ BSP Otherhousing available SealKit B=Buna-Nseals 359 V=Vitonseals 3539 Body Nomenclature No Body CP--6S CP--8S SDC--DG3B SDC--DGB P L588 Rev DA June

23 Proportional Flow Controls PSVP-NCR This is a non-compensated, normally-closed, pilot-operated, poppet-type, proportional flow-control. Controlled flow is from port to. Rated pressure 6 [377 ] Rated flow at 7 l/min [8 ] [5 ] Leakage 6 at rated pressure.6 kg [.3 lb] 8% maximum Pressure [ ] maximum differential SDC- Standard Coil M9P Watt l/min Operating Curves 6 cst [ S] hyd.oil@5 C [ F] 5 35 PSVP-NCR ( V) ( V) Pressure drop 6 cst [S] hyd.oil at 5 C [ F].9 (A).8 (A) 6 P 85 P l/min mm 3-5Nm[.-3.7bf*ft] COIL NUT KIT P/N mm Nm[5-55 lbf*ft] -/6- UN Ø3.5 [ Ø.] COIL NOT SHOWN FOR CLARITY 5.5 [.5] 5 [.77] P 86 Coil voltage = Nocoil D = V DC D = V DC Coil termination = Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ = AMP Jr PSVP-NCR-D-DN-B- Body andports =Nohousing S=Al, #SAE S=Al, #SAE B = Al, / BSP 6B = Al, 3/ BSP Otherhousing available SealKit B=Buna-Nseals V=Viton 3589 Body Nomencl. No Body CP-3-S CP-3-S CP-3-B CP-3-6B P 86 5L588 Rev DA June.3

24 Proportional Flow Controls PSVP6-NCR PSVP6-NCR This is a non-compensated, normally-closed, pilot-operated, poppet-type, proportional flow-control. Controlled flow is from port to. Rated pressure 6 [377 ] Rated flow at l/min [6 ] [5 ] Leakage 6 at rated pressure.85 kg [.87 lb] 8% maximum Pressure differential [ ] maximum SDC6- Standard Coil M9P Watt l/min 6 8 Operating Curves 6 cst [ S] hyd.oil@5 C [ F] 5 35 ( V) ( V) (A).6..8 (A) Pressure drop 6 cst [S] hyd.oil at 5 C [ F] P 66 P l/min. 6mm 38mm 3-5 Nm [.-3.7bf*ft] -36Nm[9- lbf*ft] 5/6- UN COIL NUTKIT P/N Ø37.8 [Ø.9] COIL NOT SHOWN FOR CLARITY 98.5 [3.88].7 [.76] P 868 Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ = AMP Jr PSVP6-NCR-D-DN-B- Body andports =Nohousing DG6B =Al,3/ BSP DG8B =Al, BSP S=Al, #SAE 6S=Al, #6SAE Otherhousing available SealKit B=Buna-Nseals V=Viton Body Nomencl. No Body SDC6--DG-6B SDC6--DG-8B CP6--S CP6--6S P 87. 5L588 Rev DA June

25 Proportional Flow Controls CP58-PNO This valve is a non-compensated, normally-open, proportional flow control. Rated pressure [3 ] Rated flow at 6 l/min [3 ] [8 ].36 kg [.8 lb] % maximum Threshold. A ( VDC coil). A ( VDC coil). A ( VDC coil).6 A ( VDC coil) Pressure differential [3 ] maximum SDC8- Standard Coil M9P Watt Coil nut 738 Flow vs. Current at 5.5 [8 ] pressure drop l/min 33 cst [5 S] 38 C [ F] H H Current, Amps (with VDC coil) Pressure Drop vs. Flow Coil De-Energized 33 cst [5 S] 38 C [ F] H 8H CP58-PNO P 66 L/min P 699E 5 N m MAX. [ lbf in] 7/8 HEX 7- N m [-3 lbf ft] 3/-6 UNF-A COIL NOT SHOWN FOR CLARITY INSTALL O-RING AS SHOWN 86. [3.39] 7.7 [.9] Seal kits U = Urethane 59 CP58-PNO-U-6S-H--DE Voltage = No coil = VDC = VDC P 73E Termination = No connector DE = Deutsch DN = DIN 365 FL = Lead wires AJ = AMP Jr Housing and ports Housing P/N = Cartridge only No Housing S = AL, # SAE CP8--S 6S = AL, #6 SAE CP8--6S B = AL,/ BSP SDC8--DG-B 3B = AL, 3/8 BSP SDC8--DG-3B Flow code H 8H P 655E 5L588 Rev DA June.5

26 Proportional Flow Controls PSV-NO PSV-NO This is a normally-open, direct-acting, spool-type, non-compensated, proportional flowcontrol. Controlled flow is from port to. Rated pressure 6 [377 ] Maximum flow at PSV-NO-: l/min [.6 ] [5 ] PSV-NO-5: 5 l/min [6.6 ] PSV-NO-: l/min [.6 ] Leakage cm³/min [5.6 at rated pressure.5 kg [. lb] 5% maximum Threshold. A ( VDC coil).5 A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure [ ] maximum differential SDC- Standard Coil M9P Watt l/min ( V) ( V) 5 3 Operating Curves 6 cst [ S] hyd.oil@5 C [ F] (A).6..8 (A) Pressure drop 6 cst [S] hyd.oil at 5 C [ F] 7 5 P 836 P l/min. 5 6mm 3-5 Nm [.-3.7bf*ft] COIL NUT KIT P/N Nm[33-37 lbf*ft] 7/8- UNFA 6.5 [.] COIL NOT SHOWN FOR CLARITY 86.8 [3.] 3. [.6] P 837 Maxregulated flow 5 =5l/min Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ = AMP Jr.6 5L588 Rev DA June PSV-NO-5-D-DN-B- Body andports Omit =Cartridge only 6S =Al#6 SAE 8S =Al, #8 SAE DG3B =Al,3/8 BSP DGB =Al,/ BSP Hother housing available SealKit B=Buna-Nseals 359 V=Vitonseals 3539 Body Nomenclature No Body CP--6S CP--8S SDC--DG3B SDC--DGB P 839

27 Proportional Flow Controls PSV-NO This is a normally-open, direct-acting, spool-type, non-compensated, proportional flowcontrol. Controlled flow is from port to. Rated pressure 6 [377 ] Maximum flow at [5 ] PSV-NO-6: 6 l/min [5.85 ] PSV-NO-8: 8 l/min [3.3 ] PSV-NO-: l/min [6. ] Leakage cm³/min [5.6 at rated pressure.76 kg [.68 lb] 5% maximum Threshold.3 A ( VDC coil).5 A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure differential [ ] maximum SDC- Standard Coil DE(35W) 35 Watt 6 8 l/min 8 6 Operatingcurvesmadewithcircuit havingapressure drop of. 6 cst [ S] hyd.oil@5 C [ F] ( V) (A) ( V).6..8 (A) Pressure drop 6 cst [S] hyd.oil at 5 C [ F] 85 6 PSV-NO 6 3 P 836 P l/min. 7mm 3mm 9- Nm [6-8 lbf*ft] 68-75Nm[5-55 lbf*ft] -/6- UN Coil Nut P/N Ø3.5 [Ø.] COIL NOT SHOWN FOR CLARITY 9.5 [3.7]. [.6] 5.5 [.79] P 85 Maxregulated flow =l/min Coil voltage =Nocoil D =V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ =Amp Junior AS =Amp superseal 5L588 Rev DA June PSV-NO--D-DN-B- Body andports =Nohousing S=Al, #SAE S=Al, #SAE DGB =Al,/ BSP DG6B =Al,3/ BSP Otherhousing available SealKit B=Buna-Nseals V=Viton 3589 P 87 Body Nomencl. No Body CP--S CP--S SDC--DGB SDC--DG6B.7

28 Proportional Flow Controls PSVP-NOR PSVP-NOR This is a non-compensated, normally-open, pilot-operated, poppet-type, proportional flow-control. Controlled flow is from port to. Rated pressure 6 [377 ] Rated flow at 5 l/min [ ] [65 ] Leakage 6 at rated pressure.5 kg [.9 lb] 8% maximum Pressure [ ] maximum differential SDC- Standard Coil M9P Watt l/min Operating Curves 6 cst [ S] hyd.oil@5 C [ F] 5 35 ( V) ( V) (A).6..8 (A) Pressure drop 6 cst [S] hyd.oil at 5 C [ F] P l/min. P mm 3-5 Nm[.-3.7bf*ft] COIL NUT KIT P/N Nm[33-37 lbf*ft] 7/8- UNFA Ø6.5 [Ø.] COIL NOT SHOWN FOR CLARITY P [3.] 3.9 [.6] Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ = AMP Jr PSVP-NOR-D-DN-B- Body andports =Nohousing 6S =Al, #6 SAE 8S =Al, #8 SAE DG3B =Al,3/8 BSP DGB =Al,/ BSP Otherhousing available SealKit B=Buna-Nseals 359 V=Vitonseals 3539 Body Nomenclature No Body CP--6S CP--8S SDC--DG3B SDC--DGB P L588 Rev DA June

29 Proportional Flow Controls PSVP-NOR This is a non-compensated, normally-open, pilot-operated, poppet-type, proportional flow-control. Controlled flow is from port to. Rated pressure 6 [377 ] Rated flow at 7 l/min [8 ] [5 ] Leakage 6 at rated pressure.6 kg [.3 lb] 8% maximum Pressure differential [ ] maximum SDC- Standard Coil M9P Watt l/min OperatingCurves 6 cst [ S] hyd.oil@5 C [ F] 35 5 PSVP-NOR (V) (V) (A).8 (A) Pressure drop 6 cst [ S] hyd.oilat5 C [ F] P 858 P l/min mm 3-5Nm[.-3.7bf*ft] COIL NUT KIT P/N mm Nm[5-55 lbf*ft] -/6- UN Ø3. [Ø.] COIL NOT SHOWN FOR CLARITY 86.3 [3.].9 [.77] P 865 Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ = AMP Jr PSVP-NOR-D-DN-B- Body andports =Nohousing S=Al, #SAE S=Al, #SAE B = Al, / BSP 6B = Al, 3/ BSP Otherhousing available SealKit B=Buna-Nseals V=Viton 3589 Body Nomencl. No Body CP-3-S CP-3-S CP-3-B CP-3-6B P 867 5L588 Rev DA June.9

30 Proportional Flow Controls PSVP6-NOR PSVP6-NOR This is a non-compensated, normally-open, pilot-operated, poppet-type, proportional flow-control. Controlled flow is from port to. Rated pressure 6 [377 ] Rated flow at 8 l/min [ ] [5 ] Leakage 6 at rated pressure.85 kg [.87 lb] 8% maximum Pressure [ ] maximum differential SDC6- Standard Coil M9P Watt l/min 6 35 Operating Curves 6 cst [ S] hyd.oil@5 C [ F] ( V) ( V) (A).6..8 (A) Pressure drop 6 cst [S] hyd.oil at 5 C [ F] 6 P 858 P l/min. 6mm 3-5 Nm [.-3.7bf*ft] COIL NUT KIT P/N mm -36 Nm [9- lbf*ft] 5/6- UN Ø37.8 [Ø.9] COIL NOT SHOWN FOR CLARITY 89.3 [3.5].8 [.76] P 87 Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ = AMP Jr PSVP6-NOR-D-DN-B- Body andports =Nohousing DG6B =Al,3/ BSP DG8B =Al, BSP S=Al, #SAE 6S=Al, #6SAE Hother housingavailable SealKit B=Buna-Nseals V=Viton Body Nomencl. No Body SDC6--DG-6B SDC6--DG-8B CP6--S CP6--6S P L588 Rev DA June

31 Proportional Flow Controls PFC-RC This is a pressure-compensated, restrictive-type, normally-closed, spool-type, proportional flow-control. Controlled flow is from port to. Rated pressure 6 [377 ] Maximum flow at PFC-RC-: l/min [.6 ] rated pressure PFC-RC-3: 3 l/min [7.9 ] Leakage cm³/min [5.6 at rated pressure.65 kg [.3 lb] 8% maximum Threshold.5 A ( VDC coil).5 A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure differential [ ] maximum SDC- Standard Coil M9P Watt Operatingcurvesmade withcircuit havingapressuredropof5. 6 cst [ S] hyd.oil@5 C[ F]. PFC-RC Pressurecompensation frominlet towork portat max 6 cst [ S] hyd.oil@5 C[ F] P 797 P 799 P 798 Maxregulated flow 3 =3l/min Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ = AMP Jr 5L588 Rev DA June PFC-RC-3-D-DN-B- Body andports =Nohousing 6S =Al, #6 SAE 8S =Al, #8 SAE DG3B =Al,3/8 BSP DGB =Al,/ BSP Otherhousings available SealKit B=Buna-Nseals 359 V=Vitonseals 3539 P 8 Body Nomenclature No Body CP--6S CP--8S SDC--DG3B SDC--DGB.3

32 Proportional Flow Controls PFC-RC PFC-RC This is a pressure-compensated, restrictive-type, normally-closed, spool-type, proportional flow-control. Controlled flow is from port to. Rated pressure 6 [377 ] Maximum flow at rated pressure PFC-RC-5: 5 l/min [.9 ] PFC-RC-65: 65 l/min [7.7 ] Leakage cm³/min [5.6 at rated pressure.77 kg [.7 lb] 8% maximum Threshold.3 A ( VDC coil).5 A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure [ ] maximum differential SDC- Standard Coil DE(35W) 35 Watt Operatingcurvesmade withcircuit havingapressuredropof5. 6 cst [ S] hyd.oil@5 C[ F]. Pressurecompensation frominlet to work port 6 cst [ S] hyd.oil@5 C[ F] P 797 P 85 P 8 Maxregulated flow 65 =65l/min Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ =Amp Junior AS =Amp Superseal PFC-RC-65-D-DN-B- Body andports =Nohousing S=Al, #SAE S=Al, #SAE DGB =Al,/ BSP DG6B =Al,3/ BSP Otherhousing available SealKit B=Buna-Nseals V=Viton 3589 Body Nomencl. No Body CP--S CP--S SDC--DGB SDC--DG6B P 8.3 5L588 Rev DA June

33 Proportional Flow Controls PFC6-RC This is a pressure-compensated, restrictive-type, normally-closed, spool-type, proportional flow control. Controlled flow is from port to. Rated pressure Rated flow at 6 [377 ] Leakage Threshold Pressure differential Standard Coil 6 [377 ] 9 l/min [ ] cm³/min [5.6 at rated pressure.9 kg [. lb] 8% maximum. A ( VDC coil). A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) [ ] maximum SDC6- DE(35W) 35 Watt P 797 l/min 6 8 (V) (V) 8 6 Operating curves made with circuit havingapressuredropof5. 6 cst [ S] hyd.oil@5 C [ F] (A).6..8 (A) Pressurecompensation frominlet l/min towork portat max 6 cst [ S] hyd.oil@5 C [ F] P (Differentialpressure) 5 PFC6-RC 7mm 38mm 9- Nm [6-8 lbf*ft] -36 Nm [9- lbf*ft] 5/6- UN Coil Nut P/N [.9] COIL NOT SHOWN FOR CLARITY 99.9 [3.93] 6. [.5] 6. [.83] P 85 Maxregulated flow 9 =9l/min Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ =Amp Junior AS =Amp Superseal 5L588 Rev DA June PFC6-RC-9-D-DN-B- Coil voltage =Nocoil D = V DC D = V DC Body andports =Nohousing DG6B =Al,3/ BSP DG8B =Al, BSP S=Al, #SAE 6S=Al, #6SAE Otherhousing available SealKit B=Buna-Nseals V=Viton Body Nomencl. No Body SDC6--DG-6B SDC6--DG-8B CP6--S CP6--6S P 87.33

34 Proportional Flow Controls PFC-RO PFC-RO This is a pressure-compensated, restrictive-type, normally-open, spool-type, proportional flow-control. Controlled flow is from port to. Rated pressure 6 [377 ] maximum flow at rated pressure PFC-RO-: l/min [.6 ] PFC-RO-3: 3 l/min [7.9 ] Leakage cm³/min [5.6 at rated pressure.65 kg [.3 lb] 8% maximum Threshold. A ( VDC coil). A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure [ ] maximum differential SDC- Standard Coil M9P Watt Operatingcurvesmade with circuit havingapressuredropof. 6 cst [ S] hyd.oil@5 C[ F]. Pressurecompensation frominlet to work port at max. 6 cst [ S] hyd.oil@5 C[ F] P 8 P 8 P 83 Maxregulated flow 3=3l/min Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ = AMP Jr.3 5L588 Rev DA June PFC-RO-3-D-DN-B- Body andports =Nohousing 6S =Al, #6 SAE 8S =Al, #8 SAE DG3B =Al,3/8 BSP DGB =Al,/ BSP Otherhousing available SealKit B=Buna-Nseals 359 V=Vitonseals 3539 Body Nomenclature No Body CP--6S CP--8S SDC--DG3B SDC--DGB P 85

35 Proportional Flow Controls PFC-RO This is a pressure-compensated, restrictive-type, normally-open, spool-type, proportional flow-control. Controlled flow is from port to. Rated pressure 6 [377 ] Maximum flow at rated pressure PFC-RO-5: 5 l/min [.9 ] PFC-RO-6: 6 l/min [5.9 ] Leakage cm³/min [5.6 at rated pressure.77 kg [.7 lb] 8% maximum Threshold. A ( VDC coil). A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure differential [ ] maximum SDC- Standard Coil DE(35W) 35 Watt Operatingcurvesmade withcircuit havingapressuredropof5. 6 cst [ S] hyd.oil@5 C[ F]. PFC-RO Pressurecompensation frominlet to work port 6 cst [ S] hyd.oil@5 C[ F] P 8 P 87 P 86 Maxregulated flow 6=6l/min Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ =Amp Junior AS =Amp Superseal PFC-RO-6-D-DN-B- Body andports =Nohousing S=Al, #SAE S=Al, #SAE DGB =Al,/ BSP DG6B =Al,3/ BSP Otherhousing available SealKit B=Buna-Nseals V=Viton 3589 Body Nomencl. No Body CP--S CP--S SDC--DGB SDC--DG6B P 88 5L588 Rev DA June.35

36 Proportional Flow Controls PFC6-RO PFC6-RO This is a pressure-compensated, restrictive-type, normally-open, spool-type, proportional flow-control. Controlled flow is from port to. Rated pressure Rated flow at 6 [377 ] Leakage Threshold Pressure differential Standard Coil 6 [377 ] 85 l/min [ ] cm³/min [5.6 at rated pressure.9 kg [. lb] 8% maximum. A ( VDC coil). A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) [ ] maximum SDC6- DE(35W) 35 Watt P l/min 8 6 Operatingcurvesmadewithcircuit havingapressure drop of 5. 6 cst [ S] hyd.oil@5 C [ F] ( V) (A) ( V).6..8 (A) Pressure compensation from Inlet to work port at max l/min 6 cst [ S] hyd.oil@5 C [ F] P 83 3 (Differentialpressure) 7mm 9- Nm [6-8 lbf*ft] 38mm -36Nm[9- lbf*ft] 5/6- UN Coil Nut P/N Ø37.8 [Ø.9] COIL NOT SHOWN FOR CLARITY 99.9 [3.93] 6. [.5] 6. [.83] P 89 Maxregulated flow 85=85l/min Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ =Amp Junior AS =Amp Superseal PFC6-RO-85-D-DN-B- Body andports =Nohousing DG6B =Al,3/ BSP DG8B =Al, BSP S=Al, #SAE 6S=Al, #6SAE Otherhousing available SealKit B=Buna-Nseals V=Viton P 83 Body Nomencl. No Body SDC6--DG-6B SDC6--DG-8B CP6--S CP6--6S.36 5L588 Rev DA June

37 Proportional Flow Controls PFC-PC This is a pressure-compensated, priority-type, normally-closed, spool-type, proportional flow-control. Controlled flow is from port to 3, port is bypass. Rated pressure 6 [377 ] Maximum flow at PFC-PC-: l/min [.6 ] rated pressure PFC-PC-5: 5 l/min [6.6 ] PFC-PC-: l/min [.6 ] Leakage cm³/min [5.6 at rated pressure including.6 kg [.37 lb] coil 8% maximum Threshold.36 A ( VDC coil).8 A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure differential [ ] maximum SDC-3 Standard Coil M9P Watt Operatingcurvesmade with circuit havingapressuredropof5. 6 cst [ S] hyd.oil@5 C[ F]. Pressure compensation from inlet to work port 6 cst [ S] hyd.oil@5 C[ F] PFC-PC P 789 P 79 P 79 Max regulated flow =l/min Coil voltage =Nocoil D =V DC D =V DC Coil termination: =Nocoil FL =Flying Lead DN = DIN 365 DE =Deutsch AJ = AMP Jr 5L588 Rev DA June PFC-PC--D-DN-B- Body and ports =Nohousing 6S =Al, #6 SAE 8S =Al, #8 SAE SE3B =Al,3/8'' BSP SEB =Al,/'' BSP Otherhousing available kit B=Buna-N 35 V=Viton Body Nomenclature No Body CP-3-6S CP-3-8S SDC-3-SE3B SDC-3-SEB P 79.37

38 Proportional Flow Controls PFC-PC PFC-PC This is a pressure-compensated, priority-type, normally-closed, spool-type, proportional flow-control. Controlled flow is from port to 3, port is bypass. Rated pressure 6 [377 ] Maximum flow at PFC-PC-5: 5 l/min [3. ] rated pressure PFC-PC-65: 65 l/min [7.7 ] Leakage cm³/min [5.6 at rated pressure.8 kg [.79 lb] 8% maximum Threshold.5 A ( VDC coil).5 A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure [ ] maximum differential SDC-3 Standard Coil DE(35W) 35 Watt Operatingcurvesmade withcircuit havingapressuredropof5. 6 cst [ S] hyd.oil@5 C[ F]. Pressurecompensation frominlet to work port 6 cst [ S] hyd.oil@5 C[ F] P 789 P P 86 Maxregulated flow 65 =65l/min Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch A J=Amp Junior AS =Amp Superseal PFC-PC-65-D-DN-B- Body andports =Nohousing S=Al, #SAE S=Al, #SAE B = Al, / BSP 6B = Al, 3/ BSP Otherhousing available SealKit B=Buna-Nseals V=Viton 3589 P 88 Body Nomencl. No Body CP-3-S CP-3-S CP-3-B CP-3-6B.38 5L588 Rev DA June

39 Proportional Flow Controls PFC6-PC This is a pressure-compensated, priority-type, normally-closed, spool-type, proportional flow-control. Controlled flow is from port to 3, port is bypass. Rated pressure Rated flow at 6 [377 ] Leakage Threshold Pressure differential Standard Coil 6 [377 ] 85 l/min [ ] cm³/min [5.6 at rated pressure.97 kg [. lb] 8% maximum. A ( VDC coil). A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) [ ] maximum SDC6-3 DE(35W) 35 Watt Operatingcurvesmade withcircuit havingapressuredropof5. 6 cst [ S] hyd.oil@5 C[ F]. Pressurecompensation frominlet to work port 6 cst [ S] hyd.oil@5 C[ F] PFC6-PC P 789 P [.5] P 89 Maxregulated flow 85 =85l/min Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ =Amp Junior AS =Amp Superseal PFC6-PC-85-D-DN-B- Coil voltage =Nocoil D = V DC D = V DC Body andports =Nohousing 6B = Al, 3/ BSP 8B =Al, BSP S=Al, #SAE 6S=Al, #6SAE Otherhousings available SealKit B=Buna-Nseals V=Vitonseals 3599 Body Nomenclature No housing SDC6-3-HE-6B SDC6-3-HE-8B CP6-3-S CP6-3-6S P 8 5L588 Rev DA June.39

40 Proportional Flow Controls PFC-PO PFC-PO This is a pressure-compensated, priority-type, normally-open, spool-type, proportional flow-control. Controlled flow is from port to 3, port is bypass. Rated pressure 6 [377 ] Maximum flow at PFC-PO-: l/min [.6 ] rated pressure PFC-PO-5: 5 l/min [6.6 ] PFC-PO-35: 35 l/min [9.5 ] Leakage cm³/min [5.6 at rated pressure including.7 kg [.59 lb] coil 8% maximum Threshold. A ( VDC coil).5 A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure [ ] maximum differential SDC-3 Standard Coil M9P Watt Operatingcurvesmade withcircuit havingapressuredropof5. 6 cst [ S] hyd.oil@5 C[ F]. Pressurecompensation frominlet to work port at max. 6 cst [ S] hyd.oil@5 C[ F] P 793 P 795 P 79 Max regulated flow 35 =35l/min Coil voltage =Nocoil D =V DC D =V DC Coil termination: =Nocoil FL =Flying Lead DN =DIN 365 DE =Deutsch AJ = AMP Jr. 5L588 Rev DA June PFC-PO-35-D-DN-B- Body and ports =Nohousing 6S =Al, #6 SAE 8S =Al, #8 SAE SE3B =Al,3/8'' BSP SEB =Al,/'' BSP Otherhousing available B=Buna-N V=Viton kit Body Nomenclature No Body CP-3-6S CP-3-8S SDC-3-SE3B SDC-3-SEB P 796

41 Proportional Flow Controls PFC-PO This is a pressure-compensated, priority-type, normally-open, spool-type, proportional flow-control. Controlled flow is from port to 3, port is bypass. Rated pressure 6 [377 ] maximum flow at rated pressure PFC-PO-5: 5 l/min [3. ] PFC-PO-7: 7 l/min [8.5 ] Leakage cm³/min [5.6 at rated pressure.8 kg [.79 lb] 8% maximum Threshold. A ( VDC coil). A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) Pressure differential [ ] maximum SDC- Standard Coil DE(35W) 35 Watt Operatingcurvesmade withcircuit havingapressuredropof5. 6 cst [ S] hyd.oil@5 C[ F]. Pressurecompensation frominlet to work port 6 cst [ S] hyd.oil@5 C[ F] PFC-PO P 793 P P 89 Maxregulated flow 7 =7l/min Coil voltage =Nocoil D = V DC D = V DC Coil termination =Nocoil FL =Flying Lead DN = ISO (DIN 365) DE =Deutsch AJ =Amp Junior AS =Amp Superseal 5L588 Rev DA June PFC-PO-7-D-DN-B- Body andports =Nohousing S=Al, #SAE S=Al, #SAE B = Al, / BSP 6B = Al, 3/ BSP Otherhousing available SealKit B=Buna-Nseals V=Viton 3589 P 8 Body Nomencl. No Body CP-3-S CP-3-S CP-3-B CP-3-6B.

42 Proportional Flow Controls PFC6-PO PFC6-PO This is a pressure-compensated, priority-type, normally-open, spool-type, proportional flow-control. Controlled flow is from port to 3, port is bypass. Rated pressure Rated flow at 6 [377 ] Leakage Threshold Pressure differential Standard Coil 6 [377 ] 9 l/min [ ] cm³/min [5.6 at rated pressure.97 kg [. lb] 8% maximum. A ( VDC coil).5 A ( VDC coil).8 A ( VDC coil).9 A ( VDC coil) [ ] maximum SDC6-3 DE(35W) 35 Watt Operatingcurvesmade withcircuit havingapressuredropof5. 6 cst [ S] hyd.oil@5 C[ F]. Pressurecompensation frominlet towork portat max 6 cst [ S] hyd.oil@5 C[ F] P 793 P 83 - P 8 Maxregulated flow 9 =9l/min Coil termination =Nocoil FL =Flying Lead DN =ISO (DIN 365) DE =Deutsch A J=Amp Junior AS =Amp Superseal PFC6-PO-9-D-DN-B- Coil voltage =Nocoil D = V DC D = V DC Body andports =Nohousing 6B = Al, 3/ BSP 8B =Al, BSP S=Al, #SAE 6S=Al, #6SAE Otherhousings available SealKit B=Buna-Nseals V=Vitonseals 3599 Body Nomenclature No housing SDC6-3-HE-6B SDC6-3-HE-8B CP6-3-S CP6-3-6S P 8. 5L588 Rev DA June

43 Proportional Pressure Reducing CP558- This valve is a direct acting, proportional, pressure reducing/relieving valve. Rated pressure 3 [5 ] Rated flow at 7 l/min [ ] [ ].7 kg [.6 lb] % maximum Threshold. A ( VDC coil).5 A ( VDC coil) A ( VDC coil).5 A ( VDC coil) SDC8-3 Standard Coil D8 6 Watt Coil nut Pressure S (33 cst) hyd. F (38 C) at. L/min [.3 gpm] flow Code = 35 Code = 5 Code = Current, Amps (with VDC coil) P 7E CP558-3 P 33E 3/-6UNF h.875 in t 7-3 N. m [-5 lbf. ft] 6mm 3-5 Nm[6- lbf*in] KIT P/N 556 includes nut and O-rings [.56] P 75E 5L588 Rev DA June CP558--B-S-5-D-H Seal Kit B= Buna-N 65 V=Viton 78 using and ports Housing P/N = No Housing No Housing B = AL,/ BSP SDC8-3-SE-B 3B = AL, 3/8 BSP SDC8-3-SE-3B S = AL, # SAE CP8-3-S S = AL, #6 SAE CP8-3-6S Voltage = No coil D = VDC coil D = VDC coil Pressure Code 5 =.3 [5 ] 5 = 5.5 [5 ] 35 =. [35 ] Connector = No connector H= DIN 365 L= Lead S= Spade AJ = Amp Junior M = Metripak 5 Type DE = Deutsch P 78E.3

Pressure Reducing Valves Catalog Quick Reference

Pressure Reducing Valves Catalog Quick Reference Quick Reference Pressure Reducing, Non-Relieving Model No. Description Flow* Pressure Page 2 CP20-2 SDC0- Pressure Reducing, 20 bar PR - 5 PRC 06 NCS06/ Non-Relieving, Direct Acting [000 psi] 5 bar [4500

More information

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference

Cartridge Valves Technical Information. Pressure Reducing, Quick Reference Quick Reference Pressure Reducing, Non-Relieving Model No. Description Flow* Pressure Page CP20-2 PRC 06 SDC10- NCS06/ Pressure Reducing, Non-Relieving, Direct Acting 40 l/min [10 US gal/min] 40 l/min

More information

Pilot Operated Check Valves Catalog Quick Reference

Pilot Operated Check Valves Catalog Quick Reference Quick Reference Pilot to Open Model No. Description Flow* Pressure Page RPC NCS/3 Pilot Operated Check Valve, Pilot to Open.5 l/min [5. US gal/min] RPC NCS/3 35 l/min [9.3 US gal/min] CP5- SDC-3 3 l/min

More information

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference

Cartridge Valves Technical Information. Pilot operated check valves. Quick reference Quick reference Pilot to Open Model No. Description Flow* Pressure Page P RPC 4 NCS4/ Pilot Operated Check Valve, Pilot to Open l/min [ US gal/min] RPC 6 NCS6/ 5 l/min [7 US gal/min] CP45- SDC- l/min RPC

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)

Logic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm) Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min

More information

Cover headline. Cover subheadline. Check Valves

Cover headline. Cover subheadline. Check Valves Check Valves Cover headline Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Cover subheadline EATON Screw-In Cartridge Valves E-VLSC-MC-E December

More information

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm)

Load Controls Screw In Cartridge Valves Pressures to 350 bar (5000 psi) Flows to 190 l/min (50 USgpm) Vickers Cartridge Valves Load Controls Screw In Cartridge Valves Pressures to 50 bar (5000 psi) Flows to 90 l/min (50 USgpm) Rev. 2/99 722 Contents MODEL DESCRIPTION TYP. APPLICATION PRESSURE bar (psi)

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

PRESSURE COMPENSATORS TECNORD

PRESSURE COMPENSATORS TECNORD PRESSURE COMPENSATORS 2-way, Compensating / Reducing Valves GPM PSI LPM BAR MODEL CAVITY PAGE 8 3500 30 245 DF-CP2 7/8 14 UNF 60 16 3500 60 245 QC-CP2 Special 62 Typical Schematic Typical application for

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE

MOUNTING SURFACE MOUNTING POSITION MAXIUMUM OPERATING PRESSURE FLUID OPERATING VISCOSITY FLUID CLEANLINESS HYSTERESIS REPEATABILITY THRESHOLD VOLTAGE TYPICAL PERFORMANCE SPECIFICATIONS DESCRIPTION These proportional valves are direct operated pressure reducing valves. They can be used to control pressure in parts of a circuit. This valve incorporates

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

Electro-Proportional Valves. Selection Guide HYDRA FORCE

Electro-Proportional Valves. Selection Guide HYDRA FORCE Continuous-duty rated solenoids. Hardened precision spool and cage for long life. Cartridges voltage interchangeable. Efficient wet-armature construction. Industry-common cavity. Designed for excellent

More information

PVK OPEN LOOP PUMPS. Bulletin E

PVK OPEN LOOP PUMPS. Bulletin E PVK OPEN LOOP PUMPS Bulletin 47025-E Table of Contents Performance Assurance page 3 Features and Benefits page 4-5 Specifications page 6 Pump Controls page 7 Table of Contents Curves Performance page 8

More information

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi) Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001

Xpress L90LS Directional Control Valve. Catalog HY /UK December, 2001 Xpress L90LS Directional Control Valve Catalog HY17-8525/UK December, 2001 Catalogue HY17-8525/UK Technical Information Xpress - general information Xpress is a valve-customization service that enables

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

P.C. Flow Regulator Valve Series FR101. General Description

P.C. Flow Regulator Valve Series FR101. General Description P.C. Flow Regulator Valve Series FR11 Compensated Flow Regulator Valve. NOTE: When used with a fixed displacement pump, pressure to the cartridge must be controlled by a relief valve located between the

More information

Chapter 10: Bidirectional Flow Controls

Chapter 10: Bidirectional Flow Controls Chapter 10: Bidirectional Flow Controls Objectives Learn about the patented, bidirectional flow control valves. Understand how the flow force affects the performance of the ZL70-36. Learn why there is

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options.

Function. Valve Size. Pilot Oil. p min. Bold: Designates Tier I products and options. Catalog HY14-255/US echnical Information ilot Operated ressure Reducing Valves Series VMY*6 General Series VMY*6 valves consist of the main stage with valve spools and the pilot stage with the proportional

More information

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing

More information

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm)

Pressure control. Direct and pilot operated pressure control valves for applications up to 350 bar (5000 psi) and 300 L/min (80 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Pressure control Direct and pilot operated pressure control valves for applications up to 5 bar (5 psi) and L/min (8 USgpm) Pressure control PRSSUR CONTROLS...-4

More information

Cartridge Valves Technical Information Motor Mount HICs Quick Reference

Cartridge Valves Technical Information Motor Mount HICs Quick Reference Quick Reference Symbol Description Order No. Page DH/DS MOUNT OMP/OMR/OMH MOUNT OMS MOUNT OMT MOUNT mount HIC Test lock 1125 15.21 1 1 2 2 3 3 4 4 P14 Symbol Description Model No. Page Dual counterbalance

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface ywire Elements Element 4/3 with side ports IW5 Interface efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES 398SW5EN - 5--8 Technical data Nominal flow 5 l/min 3. US

More information

Full Range Pressure Compensating Variable Flow Control

Full Range Pressure Compensating Variable Flow Control Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever

More information

directional control valve series cv691

directional control valve series cv691 directional control valve series cv691 Contents Page 3 Page 4 Page 5 Page 6-7 Page 8 Page 9 Page 10 Page 11-12 General Information Technical Data Performance Curves Dimensions Relief Valve Advantages

More information

RP series Rotor Pumps

RP series Rotor Pumps ontact etails RP series Rotor Pumps Nomenclature Features Low noise Substantial reduction of the operation noise, by to db (comparison with aikin products), and improved sound quality are achieved by adopting

More information

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Displacement 12, , Maximum flow rate (at 1450 rpm) bar. 00/07 ED PVD VARIABLE DISPLACEMENT VANE PUMPS SERIES 0 OPERATING PRINCIPLE The PVD pumps are variable displacement vane pumps with a mechanical type of pressure compensator. They allow instantaneous adjustment

More information

Directional Controls

Directional Controls Vickers Directional Controls Directional Control Valves DG3V-3-*-60 Hydraulic Operated DG17V-3-*-60 Lever Operated DG18V-3-*-60 Air Operated DG20V-3-*-60 Cam Operated DG21V-3-*-60 Plunger Operated CETOP

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE

L125 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE L15 SERIES POST-COMPENSATED SECTIONAL LOAD SENSE VALVE TAKE CONTROL Take control with Muncie Power Products L15 directional control valve. The L15 is constructed with high-grade, iron castings and nickel-plated

More information

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking: direct operated INVERSE function available Q max = 2 l/min p max = bar INVERS Description EPDB The direct operated proportional pressure relief valve is built as a slip-in cartridge fitted in a connecting

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump

Sauer Danfoss Series 90 Hydraulic Axial Piston Pump Sauer Danfoss Series 90 Hydraulic Axial Piston Pump www.hydpump.com 90R030, 90R042, 90R055, 90R075, 90R100, 90R130, 90R180, 90R250 90L030, 90L042, 90L055, 90L075, 90L100, 90L130, 90L180, 90L250 Series

More information

IFP C175-* REMOTE CONTROL RELIEF VALVE

IFP C175-* REMOTE CONTROL RELIEF VALVE IFP C175-* REMOTE CONTROL RELIEF VLVE Low Pressure Differential Quiet Operation Easy to djust Handle Three Pressure Ranges vailable Panel Mount Design P T Model Pressure Range (PSI) Rated Flow (US GPM)

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 10770-3 First edition 2007-10-15 Hydraulic fluid power Electrically modulated hydraulic control valves Part 3: Test methods for pressure control valves Transmissions hydrauliques

More information

PRESSURE SEQUENCE VALVE TYPE UZK

PRESSURE SEQUENCE VALVE TYPE UZK PRESSURE SEQUENCE VALVE TYPE UZK Size 10, 20, 30 31,5 MPa up to 450 dm 3 /min WK 450 414 04. 2000r. Pressure sequence valves type UZK are used for switching a system or part of a system off when a set

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm ort connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

SDM to 8 sections monoblock valve D1WWDA02A

SDM to 8 sections monoblock valve D1WWDA02A SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information

More information

PLD 03 T A CASAPPA S.p.A.

PLD 03 T A CASAPPA S.p.A. GEAR FLOW DIVIDERS INDEX Section Page GENERAL FEATURES... 3 GENERAL DATA... 5 FLOW EQUALIZER... 6 FLOW DIVIDERS... 8 TYPICAL CIRCUITS... 10 NOTES ABOUT COMPOSITION... 12 PORTS DIMENSIONS.... 14 GROUP DIMENSIONS...

More information

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94

Vickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94 Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model ZDR 6 D Nominal size 6 Series 4X Maximum operating pressure 20 bar (3050 PSI) Maximum flow 50 L/min

More information

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4 to 1 NPT SERIES. qwer Air and Inert Gas Valves Brass, or Stainless Steel Bodies 1/" to 1" NPT Features Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure a secondary part of a hydraulic circuit. Pressure is mataed

More information

Pressure reducing valve, pilot operated, Model 3DR

Pressure reducing valve, pilot operated, Model 3DR RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features

More information

ANTI SHOCK RELIEF VALVE

ANTI SHOCK RELIEF VALVE ANTI SHOCK RELIEF VALVE Wheeler Road Coventry CV3 4LA England Brüsseler Allee 2 D-41812 Erkelenz Tel. +44(0)2476-217-400 Fax +44(0)2476-217-488 Tel. +49(0)24 31-80 91-0 Fax +49(0)24 31-80 91-19 www.sunhydraulics.com

More information

PTS1120TSJB PTS2120TSTSJB

PTS1120TSJB PTS2120TSTSJB Engineering & Manufacturing Solutions Specifications: 18 gpm (68.0 lpm) Nominal Capacity. Rated up to 3000 psi (207 bar). Port Sizes: -Inlet/Outlet #12 SAE. -Work Ports #10 SAE. 10 Micron Filtration Recommended.

More information

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI GP1 & GP2 Electropneumatic Regulators FOR PRESSURE CONTROL TO 1, PSI GP1 & GP2 Functional Description The GP series control valve is an electronic pressure regulator designed to precisely control the pressure

More information

Service and Parts Manual Proportional Valves PVG 100 powersolutions.danfoss.com

Service and Parts Manual Proportional Valves PVG 100 powersolutions.danfoss.com MAKING MODERN LIVING POSSIBLE Service and Parts Manual Proportional Valves PVG 100 powersolutions.danfoss.com Contents Function PVG 100 sectional drawing...3 Installation Installation and plug orientation...4

More information

* Different spooltypes up to 120 l/min. in combination with simultaneously control.

* Different spooltypes up to 120 l/min. in combination with simultaneously control. APV-16 Features. * Modular assembly system, suitable for 'Build Program'. * Max. operating pressure 420 bar. * Different spooltypes up to 120 l/min. in combination with simultaneously control. * Compact

More information

Lesson 6: Flow Control Valves

Lesson 6: Flow Control Valves : Flow Control Valves Basic Hydraulic Systems Hydraulic Fluids Hydraulic Tank Hydraulic Pumps and Motors Pressure Control Valves Directional Control Valves Flow Control Valves Cylinders : Flow Control

More information

Digital electro-pneumatic regulators Series ER100

Digital electro-pneumatic regulators Series ER100 CATALOGUE > Release 8.2 Digital electro-pneumatic regulators Series ER100 TREATMENT > Digital electro-pneumatic regulators Series ER100 Port G1/4» Compact design» Digital display» Analog and digital input»

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device.

CV08-20 Check Valve DIRECTIONAL VALVES. DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. DIRECTIONAL VALVES CV08-20 Check Valve DESCRIPTION A screw-in, cartridge-style, hydraulic check valve for use as a blocking or load-holding device. OPERATION The CV08-20 allows flow passage from 1 to 2,

More information

3-Way Pressure-Reducing Cartridge, Size 2 4

3-Way Pressure-Reducing Cartridge, Size 2 4 -Way Pressure-Reducing Cartridge, Size 2 Q max = 2 l/min, p max = 25 bar Spool-type design, direct acting, with manual adjustment 1 Description Compact construction for cavity type AM /- UNF to Bucher

More information

Leak-Free Load-Control Valve SAE ½ psi flange

Leak-Free Load-Control Valve SAE ½ psi flange Leak-Free Load-Control Valve SE ½ - 6000 psi flange Q max = 150 l/min [40 gpm], p max = 420 bar [6000 psi] leak-proof, two-stage hydraulic, SE-flange design 12--S... 1 Description Two-stage load-control

More information

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics. Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum

More information

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents

More information

Priority (Swing) Motors Data and Specifications

Priority (Swing) Motors Data and Specifications s Data and Specifications Specifications HMF 55 HMF 75 HMF 105 cm 3/rev in 3/rev 55 3.36 75 4.57 105 6.40 Pressure Ratings Nominal 5000 PSIG Maximum 6090 PSIG Peak 7250 PSIG Operating Speed Maximum 4100

More information

MDC Series. Marine Grade 4-Way Directional Control Valve With Or Without Flow Control MDCF16TH304H MDC16TH404HB

MDC Series. Marine Grade 4-Way Directional Control Valve With Or Without Flow Control MDCF16TH304H MDC16TH404HB Engineering & Manufacturing Solutions Specifications: MDC rated for -4 gpm (-151 lpm) MDCF rated for -3 gpm (-114 lpm) Rate for 3 PSI (27 bar) Port Sizes #16 SAE (1-5/16-12) all ports Weighs 16 lbs. (7.3

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE Exercise 8 Closed-Loop Pressure Control, EXERCISE OBJECTIVE To understand open and closed-loop pressure control; To learn how to sense the pressure in a pneumatic circuit; To control the pressure in a

More information

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM Catalog HY14-252/US Introduction Series C, CPO, F, PRD, PR, R anapak valves provide a variety of check, flow control, pressure relief and pressure reducing functions in a compact NFPA D3, D5 and D8 sandwich

More information

2/2-Way Proportional Valve (motor-driven)

2/2-Way Proportional Valve (motor-driven) 2/2-Way Proportional Valve (motor-driven) Type 3280 can be combined with Seat valve with stepper motor - actuator isolated from flow path Excellent range (1:100) Low power consumption Fast response Orifice

More information

SPCH/ Blowing block

SPCH/ Blowing block > > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3

More information

DNS. Monoblock directional control valves DNS - Directional control valve

DNS. Monoblock directional control valves DNS - Directional control valve Monoblock directional control valves DNS - Directional control valve DNS efore use, carefully read the GENERL INSRUCIONS FOR USE OF DIRECIONL CONROL VLVES 398SMD6I - 6--8 DNS echnical data Nominal flow

More information

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2" Centered (Default)

Dimensions [All numbers in brackets are in millimeters.] K4-2 US (supplied) 1/2 Centered (Default) Proportional damper actuator, non-spring return, Multi-Function Technology Torque min. Control to 0 VDC (DEFULT) Feedback to 0 VDC (DEFULT) For proportional modulation of dampers in HVC systems. The is

More information

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module: FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-2500/US Industrial Hydraulic Valves WARNING USR RSPONSIBILITY FAILUR OR IMPROPR

More information

D e s c r i p t i o n

D e s c r i p t i o n MPS Series D e s c r i p t i o n The MPS spin-on filter series is a complete product range suitable, for both suction and return applications. Utilising spin-on canisters, the MPS series are quick and

More information

2/2-way proportional valve

2/2-way proportional valve 2/2-way proportional valve General purpose 0... 12 bar DN 0.8... 2.0 mm 1/8 or sub-base version Type 2824 can be combined with Type 805 Digital control electronics DIN-rail version Type 07 Cable plug Typ

More information

Motion Controls Valve locator

Motion Controls Valve locator Motion Controls Valve locator unctional Symbol C C Model Cavity low Rating Typical Pressure Page OCV standard L/min (USgpm) bar (psi) CE A9 (5) 7 (4) - CE A66 (8) 7 (4) - CEH A66 (8) 5 (5) - CE9 A6 9 ()

More information

Double Pilot Operated Cartridge Check Valve, Size 8

Double Pilot Operated Cartridge Check Valve, Size 8 Double Pilot Operated Cartridge Check Valve, Size 8 Q max = 7 l/min (19 gpm), p max = 35 bar (5 psi) pilot operated, two-stage, spring-closed cartridge-type poppet valve Compact design for cavity type

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

2/2-way proportional valve

2/2-way proportional valve 2/2-way proportional valve High sensitivity Type can be combined with 0... 16 bar DN 0.8... 4 mm 1/8, 1/4 or sub-base EEx approvals optional Type 8605 Digital control electronics Cable plug version Type

More information

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders

ENGINEERING DATA. PVB Piston Pumps. w w w. F l u i D y n e F P. c o m Same Day Shipments of Units or Part Orders ENGINEERING DT PV Piston Pumps Same Day Shipments of Units or Part Orders Interchangeable Parts Fully Tested w w w. F l u i D y n e F P. c o m Email:cs@FluiDyneFP.com Contents asic characteristics.........................................................................................

More information

Applications. What moves your world

Applications. What moves your world Digital Control Proportional Valves Series D92 High-performance pressure control valve with high dynamics and the ability to easily and exactly tune the pressure controller gain The pq-proportional valves

More information

Proportional Valve Group PVG 32 minibooster

Proportional Valve Group PVG 32 minibooster Technical Information Proportional Valve Group powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev February 2018 Add new modules 0201 August 2015 Drawing updated 00.04 February

More information

2/ Port G1/4

2/ Port G1/4 CATALOGUE > Release 8.8 > Series ER100 digital electro-pneumatic regulators Series ER100 digital electro-pneumatic regulators Port G1/4 Compact design Digital display Analog and digital input Programmable

More information

VSD03M DIRECTIONAL CONTROL VALVES

VSD03M DIRECTIONAL CONTROL VALVES NFPA SIZE D03 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e.

More information

Differential Pressure Transmiter

Differential Pressure Transmiter Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;

More information

PVV Open Loop Pumps. Bulletin E

PVV Open Loop Pumps. Bulletin E PVV Open Loop Pumps Bulletin 47028-E Table of Contents Table of Contents Performance Assurance page 3 Features and Benefits 4-5 Specifications 6 Controls Single Pressure Compensator 7 Single Pressure Compensator

More information

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners

Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),

More information

2-way flow control valve Model 2FRM 6

2-way flow control valve Model 2FRM 6 R 28 6/0.98 Replaces R 28 62/05.94 R 28 6/06.98 2-way flow control valve Model 2FRM 6 Nominal size 6 Series X Maximum operating pressure 4569 SI (5 bar) ) Maximum flow 8.45 GM (2 L/min) H//D 585/97 + H//D

More information

Over-center valves type LHT with oscillation damping, zero leakage

Over-center valves type LHT with oscillation damping, zero leakage Over-center valves type LHT with oscillation damping, zero leakage Flow rate Q max = 250 lpm Operation pressure p max = 450 bar See also: o Over-center valve type LHK acc. to D 7100 o Over-center valve

More information

Directional Valves. Hydraulic Operated Directional Valves

Directional Valves. Hydraulic Operated Directional Valves Service Data Vickers Directional Valves Hydraulic Operated Directional Valves (F*) DG3V 8 (B) ** (L) (X) (*) (*) 10 (EN**) Released 04/96 5007.03/EN/0496/S DG3V-8-*(C) - (X) - 10 Spring Centered 473726

More information

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC Publ. 1 - EN0709 - A 01 / 2000 / 2500 / FB Replaces : 1 - EN 084 - B L25-10709 - 1 CONTENTS GENERAL CHARACTERISTICS T67GB T6GC - T6ZC T67GB

More information

SINGLE VALVE WITH LOW-FLOW BYPASS

SINGLE VALVE WITH LOW-FLOW BYPASS CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size

More information

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min

More information

420 Mobile Piston Pump Design Code B

420 Mobile Piston Pump Design Code B 42 Mobile Piston Pump Design Code B ADU41 ADU49 ADU62 ADU8 Introduction 42 Series Mobile Piston Pump Eaton s 42 Series mobile pumps are open circuit, axial piston designs with displacements of 41cc, 49cc,

More information