1 IMP 041 ind Référence / Reference Avis de Modification Produit / Process Product / Process hange Notification PN Nb de pages / Nb of pages 1/9 Date de Diffusion / Issue Date 01/10/2016 Familles Produit / Product Families MIL-DTL series I (LJT), series II (JT), VG96912 (SJT) Références oncernées / oncerned Part Numbers Bouchons LJT, JT, SJT / LJT, JT, SJT Protective aps Origine / Origin Amphenol Socapex France Diffusion / Distribution Tous lients / All ustomers Sujet / Subject Amphenol Socapex vous informe de l évolution du design de ses bouchons MIL-DTL serie I (LJT), serie II (JT) et VG96912 (SJT) avec chainette métallique ou cordelette en nylon. Les désignations commerciales actuelles seront conservées. Amphenol Socapex is updating its MIL-DTL series I (LJT), series II (JT) and VG96912 (SJT) protective caps with chain or nylon cord. The actual part numbers will remain the same. Modification / Nature of hange Veuillez trouver ci-joint le comparatif technique des anciens et des nouveaux designs des bouchons MIL-DTL serie I (LJT), serie II (JT) et VG96912 (SJT). Il ne sera plus possible de commander ces bouchons avec l ancien design en version standard. Please find attached the technical comparison between former designs and new designs of MIL-DTL series I (LJT), series II (JT) and VG96912 (SJT) protective caps. It won t be possible to order the former design anymore in standard version. 1
2 LJT PLUG APS technical comparison SELL ØB Max Min ORD Nylon ord SELL ØB Max Min ( +12,5 /-6,35) ORD Nylon ord ( +12.5/-6.35) 9 14,53 19, ,78 23, ,59 26, ,77 30, ,94 33, ,66 35, ,83 38, ,01 42, ,18 45,47 15,21 22, ,53 20, ,78 23, ,59 27, ,77 30, ,94 33, ,66 36, ,83 39, ,01 42, ,18 46,23 14,73 22,86 76,2 76,2 88,9 88,9 101,6 101,6 2
3 LJT REEPTALE APS technical comparison Max SELL ORD RING ØB Max Max 9 21,4 21,01 17,86 24, ,6 24,1 21,44 25, ,6 28,47 25,81 35, ,8 31,57 28,98 38,5 18, , ,16 41, ,1 37,8 35,33 44, ,3 40,92 38, ,5 44,02 41,68 51, ,6 47, ,86 54,38 Max SELL ORD RING ØB Max Max ( +12,5 /-6,35) ( +12,5/-6,35) 9 20,83 21,84 17,78 26,16 76,2 76, ,88 24,89 21,34 30, ,94 29,46 25,65 35, ,99 32,51 28,96 40,64 88,9 88, ,04 35,81 20, , ,08 38,61 35,31 45, ,13 41,91 38,35 48, ,18 44,96 101,6 101,6 41,66 53, ,48 48,01 44,7 55,88 3
4 JT PLUG APS technical comparison ØB Max (in mm) (After Knurling) 8 12,01 17, ,99 20, ,05 24, ,23 27, ,40 30, ,58 33, ,75 36, ,93 40, ,10 43,31 SELL Min 8,05 13,3 111 ORD 160 ØB Max (in mm) (After Knurling) 8 12,01 18, ,99 21, ,05 25, ,23 28, ,40 31, ,58 35, ,75 38, ,93 41, ,10 44,45 SELL Min 7,87 14,48 ( +12,5 /- 6,35) ORD ( +12.5/- 6.35) 76,20 76,20 88,90 88,90 101,60 101,60 4
5 JT REEPTALE APS technical comparison Shell size SELL ORD RING ØB Max Max 8 15,98 17,60 22,63 29, ,08 20,40 25,81 35, ,47 25,00 28,98 38,50 12, ,65 28,10 32,16 41, ,75 31, ,33 44, ,10 34,40 38,51 48, ,43 37,50 41,68 51, ,60 40,60 11,9 44,86 54, ,85 43,70 48,03 57,60 Shell size SELL ORD RING ØB Max Max ( +12,5 /- 6,35) ( +12,5/-6,35) 8 16,00 19,05 22,61 30,99 76,2 76, ,33 21,82 25,65 36, ,77 26,19 28,96 39, ,28 29,36 32,00 42,67 88,9 88, ,77 32,54 14,48 35,31 45, ,12 35,71 38,35 48, ,45 38,89 41,66 52, ,62 41,68 101,6 101,6 44,70 55, ,88 44,86 48,00 58,42 5
6 SJT PLUG APS technical comparison SELL ORD SELL ORD ØB Max ±0.15 ØB Max ±0.15 ( +12.5/-6.35) ( +12,5/-6,35) 8 12,01 17, ,99 20, ,05 24, ,22 27, ,40 30, ,58 33, ,75 36, ,92 40, ,10 43,30 15,21 22, ,01 17, ,99 20, ,05 24, ,22 27, ,40 31, ,58 34, ,75 37, ,92 40, ,10 43,
7 SJT REEPTALE APS technical comparison SELL ORD RING ØB Max (in mm) (After Knurling) Max 8 15,95 18,06 14,68 19, ,05 21,06 17,86 24, ,45 25,15 22, ,65 28,52 25,81 35,3 14, ,75 31, ,98 38, ,05 34,49 32,16 41, ,45 37,85 35,33 44, ,55 40,84 38, ,85 43,82 14,1 41,68 51,2 7 SELL ORD RING ØB Max (in mm) (After Knurling) Max ( +12,5 /- 6,35) ( +12,5/- 6,35) 8 12,22 18,64 14,68 22,62 76,2 76, ,29 21,82 17,86 25, ,33 25,4 22,63 30, ,48 28,58 25,81 36,53 14,27 88,9 88, ,65 31,75 28,98 39, ,85 34,92 32,16 42, ,1 35,33 47, ,18 41,28 101,6 101,6 38,51 49, ,35 44,45 15,29 41,68 52,37
8 Références concernées et date / Affected part number and implementation date Famille / Family Références / Part Numbers Date / Date MIL-DTL series I (LJT) aps PLUG APS BF N XX YY BF N A XX YY BF XX YY BF A XX Y E308 B06 XX YY SQUARE FLANGE REEPTALE APS BE N XX YY BE XX YY E308 B00 XX YY JAM NUT REEPTALE APS BER N XX YY BER XX YY E308 B07 XX YY FOR LINE MOUNT REEPTALE APS BP N XX YY BP XX YY XX : : from 09 to 25 for MIL-DTL series I (LJT) & aps YY : Plating MIL-DTL series I (LJT), series II (JT), VG96912 (SJT) MIL-DTL series II (JT) aps PLUG APS BF N JT XX YY BF N A JT XX YY BF JT XX YY BF A JT XX YY SQUARE FLANGE REEPTALE APS BE N JT XX YY BE JT XX YY JAM NUT REEPTALE APS BER N JT XX YY BER JT XX YY FOR LINE MOUNT REEPTALE APS BP N JT XX YY BP JT XX YY XX : : from 08 to 24 for MIL-DTL series II (JT) aps YY : Plating VG96912 (SJT) aps PLUG APS BF N XX YY BF N A XX YY BF XX YY BF A XX YY SQUARE FLANGE REEPTALE APS BE N XX YY BE XX YY JAM NUT REEPTALE APS BER N XX YY BER XX YY FOR LINE MOUNT REEPTALE APS BP N XX YY 8 01/10/2016
9 BP XX YY XX : : from 08 to 24 for VG96912 (SJT) aps YY : Plating Personne à contacter pour plus d information / Person to contact for more information Support technique / Technical support technicalsupport@amphenol-socapex.fr APPROBATIONS / Approvals B. Mane N. Martemianova Engineering Marketing S. Siguret. Jullian Quality Industrial S.A.S. au capital de Euros RS Annecy APE 2611Z TVA : FR
Swimmer identification Name: First name : Birth date (AA/MM/JJ): Citizen card N o (Grants) : Email: Address: Postal code: School board: Municipality: School: School level: Check the size of the T-Shirt
More informationINTERVAL RUNNING V2.65 FOR: Vivoactive and HR, Tactic Bravo, FR230/235/630 (V2.4: FR20XT)
INTERVAL RUNNING V2.65 FOR: Vivoactive and HR, Tactic Bravo, FR230/235/630 (V2.4: FR20T) Interval Running App is the only one App allowing to manage your interval running session by vibration way. Without
More informationSLAM-SHUT VALVES. Type BM5. Process Management TM
SLAM-SHUT VALVES Type BM5 Process Management TM BM5 Slam-Shut Valves Slam-shut valves BM5 series slam-shut valve is an automatic shut-off appliance suitable for installation as safety device in regulating
More informationGUMMIKOMPENSATOR GKF8000 / GKF8130
GUMMIKOMPENSATOR GKF8000 / GKF8 Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications
More informationANB 2016 PERFORMANCE HAUTE PERFORMANCE 2016 ANB HIGH. DATE Les 9 et 10 juillet DATE July 9th and 10th, LOCATION Moncton, NB
2016 ANB HIGH PERFORMANCE HAUTE PERFORMANCE ANB 2016 DATE July 9th and 10th, 2016 LOCATION Moncton, NB SANCTIONED AND HOSTED BY Athletics New Brunswick MEET DIRECTOR Gabriel LeBlanc anb@anb.ca or (506)
More informationMaterials : Galvanized steel flanges
Size : Ends : Min Temperature : Max Temperature : DN 32 to 200 Flanges PN10/16-10 C + 80 C Max Pressure : 16 Bars Specifications : Absorb vibrations and noises Linear and angular compansion Single NBR
More informationSize : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges
Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges ISO PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications : Absorb vibrations and noises
More informationA World-Famous Lady!
A World-Famous Lady!.Brush up your Vocabulary Révisez les termes ci-dessous qui vous seront utiles pour converser avec votre interlocuteur britannique puis ouvrez le fichier son mis à votre disposition
More informationThule Chariot Cross 1 & 2 Instructions
Thule Chariot Cross 1 & 2 Instructions C.20170201 51100481 - B IMPORTANT - KEEP THESE INTRUCTIONS FOR FUTURE REFERENCE. Your child s safety may be affected if you do not follow these instructions. Conversion
More informationMaterials : Electro galvanized steel flanges
Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications : Absorb vibrations and noises
More information38999 Space grade ESA/SCC Section. MIL-DTL Space Grade Circular Connectors
38999 Space grade ESA/SCC 3401 Section II MI-DT 38999 Space Grade Circular Connectors 59 38999 Space Grade ESA/SCC 3401 Contents 38999 Space Grade ESA/SCC 3401 SCC Specification.......................................................61
More informationMartin Lavallière, Martin Simoneau, Normand Teasdale, Denis Laurendeau Université Laval
How could we help older drivers to increase their driving performance? Comment pourrions-nous aider les conducteurs âgés à améliorer leur performance au volant? Martin Lavallière, Martin Simoneau, Normand
More informationHYSTER FORTENS H1.60/1.80 FT H2.00 FTS LIVRET PIECES DE RECHANGE SPARE PARTS CATALOGUE
C A B I N E S /8 Site INTERNET : www.sarrazin.fr E mail : contact@sarrazin.fr FORTENS H.60/.80 FT H.00 FTS LIVRET PIECES DE RECHANGE SPARE PARTS CATALOGUE Référence : SZ5.05.86 Kit cabine rigide Réf. SZ5.5.080
More informationChesapeake Bay. Sea - Seek. Ebook Sailing guide / Guide nautique. Chesapeake Bay. NW Atlantic Ocean - US - East coast
Sea - Seek Ebook Sailing guide / Guide nautique NW Atlantic Ocean - US - East coast Table of contents... 1 1 - Anchorage Marina (Baltimore)... 2 2 - Fairlee Creek... 2 3 - Craighill Channel... 3 4 - Craighill
More informationRECOMMANDATION GÉNÉRALE D UTILISATION PORTE-CLIPS PORTE-LANGUETTES 16 VOIES HYBRIDE
GENERAL UTILIZATION RECOMMENDATION RECEPTACLE HOUSING 03 Juillet 07 Rév. C 1. INTRODUCTION 1. INTRODUCTION 1.1. Présentation du produit 1.1 Product description HOUSING SLIDE "DL" Figure 1 Le Porte-clips
More informationParts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08
Parts Manual STRIKER 2840 Striker 2840 Parts List - PN 238155 - Printed in USA 03/18/08 Standard Parts Recommended General Wear Parts Ref No Part Description Qty Part No 1 Squeegee Hose Assembly
More informationINSTRUCTIONS PARTS LIST U.S. PAT: 6,874,404; 6,516,707; 6,223,645
3076-AFCM-000 INSTRUCTIONS PARTS LIST INSTRUCTIONS! This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. AQ Air Flow Control (3076-AFC3-000) (3076-AFC4-000) U.S. PAT: 6,874,404;
More informationDistributeurs commande manuelle à levier
Distributeurs commande manuelle à levier Lever actuated valves Informations générales General information Distributeurs 3/2-5/2-5/3 à raccordements - G1/4 - G3/8 - G1/2 - G3/4 3/2-5/2-5/3 spool valves
More informationElectromechanical pressure switches
References : pages / and / page /5 Presentation Functions Pressure switches type XMX and XMA are switches for control circuits, with an adjustable differential. They are used to control the pressure of
More informationPRESSURE REGULATORS. Type B/240. Process Management TM
PRESSURE REGULATORS Type B/240 Process Management TM B/240 Series Pressure Regulator The regulators of the B/240 series due to their operating specifications are mainly used in those system where sudden
More informationSerie 06-M6. Swing wafer check valve. made in. Application fields. Check valves E U R O P E WATER CONDITIONING INDUSTRY
Swing wafer check valve BRANDONI made in E U R O P E Application fields WATER CONDITIONING INDUSTRY HEATING 38 www.brandoni.it The valves in series 06 are swing wafer check valves, manufactured in accordance
More informationMagnetic level switch type MR783 Instruction Manual
Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2
More information10th FRENCH OPEN of SHINKYOKUSHINKAI KARATE INTERNATIONAL TOURNAMENT KO FIGHTS SATURDAY 24 of MARCH 2018 LOOS (LILLE NORTH OF FRANCE)
Lille, November 30th, 2017 Shihan, Sensei, Sempai & Dojo operators, We have the pleasure to invite you to the 10 th French Open of Shinkyokushinkai Karate 2018, International Tournament with knockdown
More informationSLAM-SHUT VALVE. Type OSE CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual. Material. Product Description. Connections
Instruction Manual D103687X012 June 2017 Type OSE SLAM-SHUT VALVE CONTENTS Introduction... 1 Characteristics... 1 Labelling... 2 Dimensions and Weights... 3 Operation... 4 Installation... 4 Commissioning...
More informationAttention. Chainguards. Cranks and Chains. Flywheel Sprocket
Attention When ordering parts for newer Schwinn IC Pro cycles reference the following service bulletins to ensure you are ordering the correct revisions. Handlebar and sleeve Chainguards Cranks and Chains
More informationCLASS TLP Pressure Reducing Valve
CLASS TLP Pressure Reducing Valve CLASS TLP Direct Acting Pressure Reducing Valve The Class TLP balanced direct acting pressure regulator is designed for use on installations that have varying inlet pressures
More informationINSTRUCTIONS PARTS LIST
3066V-E INSTRUCTIONS PARTS LIST INSTRUCTIONS! This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. AQ Poppet Color Valve (3066-41-00A) 304 Stainless Steel Body Autoquip,
More informationFlow controller Type ED/CCB311 Instruction manual
Flow measurement Flow controller Type ED/CCB311 1. GENERAL DESCRIPTION page 4 2. DETAILED DESCRIPTION page 4 3. PIPE - EXPLOITATION page 5 4. PREVENTIVE MAINTENANCE page 5 5. REPLACEMENT OF THE CONTACT
More informationPISTOCHE & WOODEN POOL STRUCTURES
PISTOCHE & STRUCTURES BOIS PISTOCHE & WOODEN POOL PISTOCHE & STRUCTURES BOIS PISTOCHE & WOODEN POOL STRUCTURES 9 PISCINE BOIS PISTOCHE PISTOCHE WOODEN POOL 97 MARGELLES COPING 00 STRUCTURES BOIS WOODEN
More informationAutomatic Twin Greasing System
Parts Manual Automatic Twin Greasing System YOUR EFFICIENCY IS OUR CHALLENGE All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm or
More informationBODY-CARCASSE (C)2011
BODY-CARCASSE ITEM CODE REF. NO DESCRIPTION DESCRIPTION 1 3002102 YC1-3002102 Wheel support Support de roue 2 4398848 GB/T96 Washer 6 Rondelle 6 3 4398108 GB/T70.1 Self-tapping screw M6X16 Vis auto-taraudeuse
More informationSLAM-SHUT VALVES. Type BM6X. Process Management TM
SLAM-SHUT VALVES Type BM6X Process Management TM Slam-shut valves The BM6X series axial flow slam-shut valve is an automatic shut-off appliance suitable for installation as a safety device in regulating
More informationSize : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body
Size : Connection Ends : Min Temperature : Max Temperature : DN 50 to 200 Flanged ISO PN 10/16 ( ISO PN16 for DN200 ) 0 C + 50 C Max Pressure : 16 Bars Specifications : Tangential type Dry dial Magnetic
More informationHydraulic comparison test pump Models CPP1000-X, CPP1600-X
Calibration Hydraulic comparison test pump Models CPP1000-X, CPP1600-X WIKA data sheet CT 91.12 for further approvals see page 2 Applications Calibration service companies and service industry Maintenance
More information2-Liter Pressure Cup. Instructions - Parts List C
Instructions - Parts List 2-Liter Pressure Cup 309925C Model 234413 50 psi (345 kpa, 3.4 bar) Maximum Fluid Pressure 160 psi (1.1 MPa, 11 bar) Maximum Air Inlet Pressure This manual contains important
More informationDyna-Star HP Pump System
Instructions, Repair and Parts Dyna-Star HP Pump System 332540B EN Provides lubricant flow and pressure to operate a single line parallel automatic lubrication system. For automatic lubrication systems
More informationFeature Other Straps : Standard black webbing 44 mm PES with PTFE treatment (water repellent / anti stain) Breaking strength :> 2700 dan
Europe / Africa PRODUCT NUMBER: 1033537 Miller H-Design BodyFit auto 2LO Size 2 Miller H-Design BodyFit harness with 2 sternal webbing loops and automatic buckles on chest and legs straps and DuraFlex
More informationMaterials : Dichromate zinc plated steel flanges
Size : Ends : Min Temperature : Max Temperature : DN 25 to 300 Flanges PN10/16-35 C + 130 C Max Pressure : 16 Bars up to DN150, 10 bars over Specifications : Absorb vibrations and noise Linear and angular
More informationATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1
ATH 500 M Compact integrated drive Installation in any orientation Water or air cooled CE marked and ROHS compliant Heated version (MT) available for corrosive applicaitons. Pumping speed N 2 He H 2 Ar
More informationRO ROE47137 Kupplungsbolzen Coupling pin Axe d accouplement. Reparaturanleitung Repair instructions Manuel de réparation
RO 244-2 Reparaturanleitung Repair instructions Manuel de réparation D G F ROE47137 Kupplungsbolzen Coupling pin xe d accouplement Inhalt Contents Sommaire RO 244-2 D Voraussetzung zum Wechsel des Kupplungsbolzens
More informationPRESCODEM400, PRESCODEM400/220
Sinorix PRESCODEM400, PRESCODEM400/220 Sinorix CDT-V, Sinorix H2O Jet Removable contact pressure gauge with electrical connector Allows to visually check the pressure of the cylinder on which it is mounted
More informationMS Back-up, Spiral
MS 28782 Back-up, Spiral 1. Material: MIL-R-8791. 2. Surface must be smooth and free from irregularities. 4. Z gap dimension to be met with retainer over a mandrel of M diameter +.000 -.002. 5. Dash numbers
More informationBACK PRESSURE VALVE. Instructions Parts List J
Instructions Parts List BACK PRESSURE VALVE 306770J 300 psi (2.1 MPa, 21 bar) Maximum Inlet Pressure 180 psi (1.2 MPa, 12 bar) Maximum Regulated Pressure Model 206019, Series F For use with Monark, President
More informationMaterials : Dichromate zinc plated steel flanges or AISI 316
Size : Ends : Min Temperature : Max Temperature : DN 25 to 300 Flanges PN10/16-35 C + 90 C Max Pressure : 16 Bars (10 bars at 90 C) Specifications : Absorb vibrations and noise Linear and angular compansion
More informationBall Valves, Check Valves, and Swivels
Instructions -Parts List HIGH PRESSURE FLUI LINE Ball Valves, Check Valves, and Swivels 308ZAB EN Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.
More informationPRESSURE REGULATORS. Type A/140. Process Management TM
PRESSURE REGULATORS Type A/140 Process Management TM A/140 Series Pressure Regulator The regulators of the A/140 series due to their operating specifications are mainly used in those system where sudden
More informationInstallation/User s Guide Guide de l Utilisateur Installations- /Gebrauchsanleitung. U.S. Patent No. 7,922,246. Patent Pending
Installation/User s Guide Guide de l Utilisateur Installations- /Gebrauchsanleitung For International Markets U.S. Patent No. 7,922,246 Patent Pending 2 Table of Contents Page General Information... 3
More informationThe club and town of Condé sur l Escaut, judo capital on October 21 st 2017
ARTS MARTIAUX CONDE Affiliated to the F.F.J.D.A. under the n 01.59.339.0 Approved by «Jeunesse et Sports» (Youth and Sports) under the n 59 S 1925 www.amconde.fr Adresse: 552 rue de la Chaussiette 59163
More informationSerie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection
Flanged back flow preventer with controllable reduced pressure zone made in Application fields WATER FIRE FIGHTING DRINKING WATER 64 www.brandoni.it The ECO 3F flanged backflow preventers, which have a
More informationGUKO FDA. einfach. gut. beraten.
GUKO FDA Size : Ends : Min Temperature : Max Temperature : DN 25 to 300 Flanges PN10/16-25 C + 90 C Max Pressure : 16 Bars Specifications : Absorb vibrations and noise Linear and angular compansion Inner
More informationL21S/SR/ST Glass Level Gauges
L21S/SR/ST Glass Level Gauges Doc. no.: 150, en_cat_l21s/sr/st, 12/2014 Type of code Example: L21ST/1450/AANSI 3/4 150Lb RF/Large chamber Code 1 Basic type L21 2 Type of gauge S Tubular level gauge SR
More informationOPERATING INSTRUCTIONS
0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0
More informationBack Pressure Regulator
Instructions Parts List STAINLESS STEEL, WATERBASE COMPATIBLE Back Pressure Regulator 308401E For use in circulating systems to provide regulated back pressure to spray gun(s) and to maintain proper system
More informationBASIN AND WALL MIXER INSTALLATION INSTRUCTIONS
BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION IMPORTANT All tapware and showers to be installed by a licensed plumber and to Australian Standards. Fit tempering and pressure reduction
More information2-Quart (1.9 Liter) Pressure Cup
Instructions-Parts 2-Quart (1.9 Liter) Pressure Cup 312111A For controlling atomizing air and fluid pressure for any pressure feed manual spray gun when more than one quart of fluid will be used. 288776
More informationVannes à levier de commande Manually actuated valves
Vannes à levier de commande Distributeurs /-/-/ à raccordement G/8 -G/ -G/8 -G/ /-/-/ spool valves with G/8 -G/ -G/8 -G/ threaded ports Installation dans toutes les positions Installation in any position
More informationSCRUBBER DRIER SCL COMFORT XXS66 - LWS
SCRUBBER DRIER SCL COMFORT XXS66 - LWS Content filters: validity 8.579.0001 - SCRUBBER DRIER SCL COMFORT XXS66 - LWS...3 R85790001 - LAVASCIUGA COMFORT XXS 66 -GR.CH./GR.SC.- LWS... 4 R55092121 - GRUPPO
More informationFRM. Medium Pressure Regulator. Medium pressure regulator Type FRM
FRM Medium Pressure Regulator Medium pressure regulator Type FRM Direct acting pressure regulator with adjustable setpoint springs and modular mounted safety shutoff valve (SAV) In compliance with EN 334
More informationFloat valves Types SV 4, SV 5 and SV 6
Data sheet Float valves Types SV 4, SV 5 and SV 6 SV 4-6 are for use on the low pressure side as modulating liquid level regulators in refrigeration, freezing and air conditioning systems with ammonia
More informationAmphenol RF. Type N. Type N Connectors. Type N. Description. Features/Benefits. Applications
Amphenol RF 144 Connectors Description Named after Paul Neill of Bell Labs after being developed in the 1940 s, the offered the first true microwave performance. The connector was developed to satisfy
More informationNEEDLE VALVES TYPE RA
R NL VLVS TYP R The products are included in pressure adjusting accessories class. They are designed according to main requests regarding the security assurance of the pressure equipment users, mentioned
More informationFor use with all Graco/Gusmer spray guns (not included). 3 Gallon Solvent Tank
Instructions - Parts Gun Service Kits 311340C EN For use with all Graco/Gusmer spray guns (not included). Part No. 296980 1 quart (0.95 liter) Solvent Cup 120 psi (0.83 MPa, 8.3 bar) Maximum Working Fluid
More informationDifferential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting
Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting Description AVP(-F) is a self-acting differential pressure controller primarily for use in district heating systems.
More informationSerre-Chevalier. Stone and wood chalets, a pristine lake, pure Alpine bliss. France Hautes-Alpes - Serre Chevalier.
Serre-Chevalier France Hautes-Alpes - Serre Chevalier Stone and wood chalets, a pristine lake, pure Alpine bliss Resort highlights Relaxing at Club Med Spa by PAYOT Leave your babies from 4 months upwards
More informationGas Appliance Pressure Regulators with integrated gas filter. FRI/6 Series
Gas Appliance Pressure Regulators with integrated gas filter FRI/6 Series CSA Certified ANSI Z21.18 / CSA 6.3 Gas Appliance Pressure Regulator File # 1135455 EU Gas Appliance Directive EN 88 CE-0087 AU
More informationBall Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"
Data Sheet 819584-00 Issue Date: 01/17 Ball Float Steam Trap UNA 43 PN 16/C 125/JIS 10K UNA 46 PN 40/C 150/C 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6" UNA 43 hl, UNA 46 hl UNA 43 v, UNA 46 v with
More informationINSTRUCTIONS-PARTS LIST
INSTRUCTIONS-PARTS LIST 307 22 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. Rev. T Supersedes Rev. R and PCN T STAINLESS
More informationPressure Reducing Valve DMV 750 set range: bar
Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long
More informationSize : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :
Reinforced lug for DN200 : Size : Ends : Min Temperature : Max Temperature : DN 50 to 200 mm Between flanges ISO PN10/16 ( PN10 for DN200 ) - 10 C + 110 C Max Pressure : 10 Bars Specifications : Long neck
More informationDual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series
Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked
More information22èmes. Atlantic Games. Saint-Nazaire. Loire-Atlantique / Pays de la Loire. l évènement nautique des jeunes européens
22èmes Atlantic Games l évènement nautique des jeunes européens Saint-Nazaire Loire-Atlantique / Pays de la Loire du 26 au 31 août 2018 Toutes les infos : www.atlanticgames.eu 22 nd ATLANTIC GAMES PAYS
More informationK0709 Quick-fit couplings
Joints 1067 K0709 Quick-fit couplings with radial offset compensation external thread D1 SW SW1 application example: X max. D D 3 4 internal thread SW 3 4 2 SW1 D D Coupling part and claw in steel. Nut
More informationHydraulic hand spindle pump Models CPP1000-M, CPP1000-L
Calibration Hydraulic hand spindle pump Models CPP1000-M, CPP1000-L WIKA data sheet CT 91.05 for further approvals see page 2 Applications Calibration service companies and service industry Calibrations
More informationTable of Contents. 1.0 Purpose... 3
I322 Rev. A / MFP9720198 31 October 2012 Table of Contents 1.0 Purpose... 3 2 Use this Miller Leading Edge Self-Retracting Lifeline Instruction Manual Supplement in conjunction with the Miller Self-Retracting
More informationRELIEF VALVES. V Series. Process Management TM. Type V/20-2. Type V/50. Type V/60
RELIEF VALVES V Series Type V/2-2 Type V/5 Type V/6 Process Management TM V/5 and V/6 Series Spring-Loaded Relief Valves The spring-loaded relief valves are designed to keep line pressure below preset
More informationà Lille, capitale des Flandres, que se trouve le centre de conception mondiale de la marque B TWIN : le «B TWIN Village».
à Lille, capitale des Flandres, que se trouve le centre de conception mondiale de la marque B TWIN : le «B TWIN Village». Et c est au cœur de celui-ci que les concepteurs de la marque imaginent, conçoivent
More informationElectromechanical pressure switches
Presentation Electromechanical pressure switches OsiSense XM For power circuits, type XMP Presentation Pressure switches type XMP are switches for power circuits (direct switching), with an adjustable
More informationUniversal Charging and Testing Unit FPU-1
1. DESCRIPTION 1.1. FUNCTION The charging and testing unit FPU-1 is used to charge accumulators with nitrogen or to check or to change the existing pre-charge pressure in accumulators. For this purpose
More informationABS-DWV Fittings / Raccords ABS DÉÉ
Price Sheet / Liste de prix: ADWV-0314 Effective/En vigueur: March 3, 2014 / 3 mars 2014 ABS-DWV Fittings / Raccords ABS DÉÉ NCI Canada Head Office Entrepôt Montréal Warehouse Western Warehouse 66 Don
More information2016 Notice of Motion
2016 Notice of #1 brought by: Baseball NB Executive approved by: Baseball NB Executive proposed: Remove Hosting Responsibilities #6 Original: Baseball New Brunswick will assess each team eligible for zone
More informationColor/Catalyst Dispense Valves
Instructions-Parts Color/Catalyst Dispense Valves 332454C EN To dispense color, catalyst, solvent, and acid in a ProMix PD2K Electronic Proportioning System with the color change option. For professional
More informationOPERATION. Zinc Sprayer. For Maximum Working Pressure see page 2. Rev. E
OPERATION 309362 Rev. E U.S. Patent Pending Related manuals Zinc Sprayer....... 309340 List of Models, page 2 For Maximum Working Pressure see page 2....... 309092, 308438.. 307049.. 309342 INSTRUCTIONS
More informationData sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119
Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,
More informationSerie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E
Serie ECO T Threaded end back flow preventer with controllable reduced pressure zone BRANDONI made in E U R O P E Application fields WATER FIRE FIGHTING DRINKING WATER 74 www.brandoni.it Serie ECO T The
More informationINDUSTRIAL THERMOMETER
TMT703 INDUSTRIAL THERMOMETER The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the
More informationFeed and Solvent Flush Kits
Instruction - Parts Feed and Solvent Flush Kits 310863M EN For use with proportioner systems. For professional use only. Important Safety Instructions Read all warnings and instructions in this manual.
More informationHON R100 Series High Pressure Regulator Ensuring Reliable Gas Operations
HON R100 Series High Pressure Regulator Ensuring Reliable Gas Operations Proven Technology. Superior Performance. Today s natural gas industry requires precision instrumentation to maintain proper gas
More informationExpansion Thermometers Stainless Steel Series, Model 70
Mechanical Temperature Measurement Expansion Thermometers Stainless Steel Series, Model 70 WIKA Data Sheet TM 81.01 Applications General-purpose temperature measuring instruments for gaseous, liquid and
More informationNOTICE WARNING MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR
MDX-R3 FOR FIBERGLASS POOLS OWNER S MANUAL AND INSTALLATION GUIDE SUBMERGED SUCTION OUTLET FOR MULTIPLE DRAIN USE FOR USE ON FLOOR SEE SPECIAL INSTRUCTIONS FOR CALIFORNIA ON PAGE 7 Safety compliant according
More informationInstructions Parts List
Instructions Parts List AIR-OPERATED Fluid Pressure Regulator 308098H 100 psi (0.7 MPa, 7 bar) Maximum Fluid and Air Pressure Part No. 235287 Standard Fluid Pressure Regulator For use with low pressure
More informationMDM Accessories
Accessories General Hardwares are the screwlock assemblies or the brackets used for the mounting of connectors on panels or PC, or for the fixing of plugs and receptacles. They are not fixed on the connectors
More informationPEM-EX-C. Figure: PEM-EX-C*A*G. ka054000en; Rev. 2.7 J
PEM-EX-C J2013329 Figure: PEM-EX-C*A*G Robust and safe pressure transducer for general mining applications In combination with a Kirchgaesser multi channel signal converter and display unit COMBA-EX or
More informationFIA Liste N 40 IMPORTANTE / IMPORTANT
SIEGES DE COMPETITION HAUTE PERFORMANCE HOMOLOGUES SELON LA NORME FIA 8862-2009 ADVANCED RACING SEATS HOMOLOGATED ACCORDING TO THE FIA STANDARD 8862-2009 NON VALABLE APRÈS LE 31.12.2021 NOT VALID AFTER
More informationTignes Val Claret. Challenge your skiing skills as you walk in the footsteps of champions. France Savoie - Tignes Val Claret.
Tignes Val Claret France Savoie - Tignes Val Claret Challenge your skiing skills as you walk in the footsteps of champions Resort highlights Flirting with the summits in a friendly, modern Resort Downhill
More informationCAM & GROOVE COUPLINGS (for Liquid, Bulk and Chemical Transfer)
CAM & GROOVE COUPLINGS (for Liquid, Bulk and Chemical Transfer) CAMPBELL COBRA VS. STANDARD COBRA COBRA is the trade name for our entire line of cam & groove couplings. Campbell COBRA is the upgraded versions
More informationDifferential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting
Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in
More informationDamao Range. Single & Double Line Pressure Regulator - 4 or 8 bar
Damao Range Single & Double Line Pressure Regulator - 4 or 8 bar Single and Double line pressure regulator for double stage medical gas distribution systems. 10 to 4 bar pressure regulator for all medial
More informationSpare parts list ( ) Spare parts list HD 2.3/15 C Ed/ 3.0/20
Spare parts list (5.970-616.0) Spare parts list HD 2.3/15 C Ed/ 3.0/20 23.09.2011 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HD 2.3/15 C Ed/ 3.0/20 (5.970-616.0)... 6 10
More informationGENO -Flushing Compressor Product Data Sheet F 02
GENO -flushing compressor 1988 K Fig. 1: GENO -flushing compressor 1988 K Designated application is suitable for the following fields of application: Flushing of pipes with water/air mix prior to the start-up
More informationSpare parts list ( ) Spare parts list HD 1030 B
Spare parts list (5.958-299.0) Spare parts list HD 1030 B 03.09.2012 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HD 1030 B (5.958-299.0)... 6 10 Individual parts (0.102-307.0)...
More information