Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

Size: px
Start display at page:

Download "Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7"

Transcription

1 V A L V E S A i r V a l v e s

2 Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Direct solenoid and solenoid pilot operated valves Remote air valves Mechanically and manually operated valves Bases according to ISO 5599 Pressure regulators Pressure control systems Options

3

4 Introduction Welcome into your brand new MAC VALVES catalogue. Inside you will find more than different products to meet the majority of industrial requirements. They have been sorted and classified in such a way that you will find the requested valve very easily. For more than 50 years, MAC has based all new valve developments upon the specifications received from users. A lot of different modifications have been released for all fields of industry (automotive, aluminium, packaging, food, sorting,...). They are not listed in this catalogue but our technical and sales services will be pleased to provide all necessary information. All our representatives have a transportable demonstration kit to show you the specific design features of MAC Valves in terms of : reliability consistency and repeatability Feel free to ask for a personal demonstration, our team is at your disposal. MAC Valves, Your Partner

5 Introduction I Test programme "100 % of production tested 100 %" Qualitest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`7JT XY XY XY XY XY XY M.,_,T.#S7T?#@9.88:9.#A.B.J.9T7`7JT XY XY XY XY XY XY M.,_,T.#M;]#@9.88:9.#.J.9T7`7JT XY XY XY XY XY XY M.,_,T.#M;]#@9.88:9.#A.B.J.9T7`7JT XY XY XY XY XY XY All produced MAC valves are submitted to a test programme checking electrical and pneumatical parameters. Checking of coil electrical insulation. MAC manufacture their own coils and they are tested during production as well as at the end of the assembly. A 1750 V voltage is applied to the solenoid to check the insulation. Checking of the PULL- voltage. The PULL- voltage is the minimum voltage at which the valve shifts with the solenoid energized. As a standard,we guarantee the PULL- at 80 % of nominal voltage. Checking of the DROP-OUT voltage. The DROP-OUT voltage is the maximum residual voltage at which the valve shifts back. This voltage depends on the coil electrical characteristics. It is always higher than a minimum voltage specific to any coil. Checking of the valve operation when submitted to a minimum electrical signal. This test checks if the valve shifts when submitted to a short electrical voltage impulse equal to 85 % of the nominal voltage. Checking of the valve operation when submitted to ON/OFF cycles at 85 % of nominal voltage. Checking of the manual operator. This test to check if the manual override is operational. Checking of the leakage rate. The acceptable leakage rate on MAC valves is maximum 50 cm 3 /min. (100 cm 3 /min.) It is checked with the valve in all possible configurations.

6 Introduction 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS II MAC Valves warranty of 18 months The MAC Valves organization has established a reputation over many years for fulfilling the needs and requirements of the users of its products. All MAC Valves are quality products specifically designed and built for long and rugged service. Therefore, all valves appearing in this catalog are guaranteed for a period of eighteen months from the original date of shipment from our factory. In addition to this eighteen month Guarantee, MAC Valves, Inc. guarantees the electrical coils on every one of the valves listed in this catalog for life. III The flat rate rebuild programme Valves no longer covered by the MAC Guarantee can be rebuilt under the Flat Rate Rebuild programme. Our constant research and testing programme is dedicated to extending the life of our valves and making them even more reliable under the most adverse operating conditions. Valves returned under this programme are completely disassembled, inspected, rebuilt to current operating standards wherever possible, tested and returned within a few weeks for a nominal flat rate charge. All rebuilt valves carry for 90 days from date of shipment from our factory the same guarantee as provided for new valves. IV Pneumatic functions All valves inside the MAC product range allow for multiple pneumatic functions. Direct solenoid and solenoid pilot operated valves could be used as 2 ways, 3 ways (NO, NC) or 4 ways. When plugging one orifice to achieve a 2 ways function (or 3 ways), it will not affect the valve operation. Direct solenoid valves 3 ways : universal The following functions are available - 3 ways NC - 3 ways NO - 2 ways NC - 2 ways NO - Selector - Divertor Direct solenoid valves 4 ways : The following functions are available - 4 ways - 3 ways NC - 3 ways NO - 2 ways NC - 2 ways NO - Divertor Pilot operated valves 3 ways : The following functions are available - 3 ways NC - 3 ways NO - 2 ways NC - 2 ways NO - Selector : the highest pressure is connected to the port; the lowest pressure is connected to the EXH port. (Use external pilot when the highest pressure is less than 2 bar) - Divertor (consult factory) Pilot operated valves 4 & 5 ways : The following functions are available - 4 or 5 ways - 3 ways NC - 3 ways NO - 2 ways NC - 2 ways NO - Selector (except 3 positions) - Divertor (consult factory).

7 Introduction V Vacuum applications All valves inside the MAC product range may be used for vacuum applications. Direct solenoid valves 3, 4 and 5 ways The vacuum source may be connected to any one of the ports. The pressure if any (selector vacuum - pressure) may be connected to one unused port. Pilot operated valves 3, 4 & 5 ways Connect the vacuum source to one exhaust port and pressure to the inlet port. If the inlet pressure is lower than 2 bar (also with atmospheric pressure), use external pilot. OPERATG DATA 5 2 EXH TERNAL OR EXTERNAL PILOT a) From internal to external pilot - remove the 1/4" or 1/8" (59 Series) plug from EXT.PILOT port; - remove the check valve (top plate for 59 Series); - insert a 1/8" plug in the EXT. PILOT port; - connect the air supply (minimum 2 bar). b) From external to internal pilot - remove the 1/8" plug from EXT. PILOT port; - insert the check valve; - plug the EXT. PILOT port with 1/4" plug (1/8" for 59 Series). SGLE PRESSURE SUPPLY Connect the air supply to the port. CYL. DUAL PRESSURE SUPPLY For 2 different pressures or for selector applications with vacuum, the highest pressure must be connected to the port while the lowest pressure (or vacuum) will be connected to the EXH port. IMPORTANT NOTICE Never plug the PILOT EXH port. Do not use the PILOT EXH port as external pilot supply. The pilot EXH port is only designed to collect the pilot exhaust. 4 3 FUNCTION PLATE This plate is marked 3-NC (3 ways normally closed) and 3-NO (3 ways normally open). Turning the plate upside down changes the valve function from NC to NO and vice-versa.

8 Direct solenoid and solenoid pilot operated valves Flow (Max) Function Port size Nl/min Individual mounting Series inline sub-base sub-base "plug-in" 3/2-2/2 M /2-2/2 G1/ /2-2/2 G1/8-1/ /2-2/2 G1/8-1/ /2-2/2 G1/8-1/ /2-2/2 G1/4-3/ /2-2/2 G3/8-1/2-3/ /2-2/2 G1/2-3/ /2-2/2 G1-1 1/4-1 1/ /2-2/2 G2-2 1/ /2 M5 - G1/ /2 G1/8-1/ /2-4/3 G1/8-1/ /2-4/3 G1/8-1/4-3/ /2-4/3 G1/4-3/ /2-4/3 G1/4-3/8-1/ /2-4/3 G3/8-1/2-3/ /2-4/3 G3/ /2-4/3 G3/ /4-1 1/ /2 M /2-5/3 G1/8-1/ /2-5/3 G1/ /2-5/3 G1/4-3/ ISO 1 5/2-5/3 G3/8-1/ ISO 2 5/2-5/3 G1/2-3/ ISO 3

9 Direct solenoid and solenoid pilot operated valves Flow (Max) Function Port size Nl/min Manifold mounting Series stacking sub-base sub-base with pressure regulators sub-base with pressure and flow regulators sub-base "plug-in 3/2-2/2 M /2-2/2 G1/ /2-2/2 G1/8-1/ /2-2/2 G1/8-1/ /2-2/2 G1/8-1/ /2-2/2 G1/4-3/ /2-2/2 G3/8-1/2-3/ /2-2/2 G1/2-3/ /2-2/2 G1-1 1/4-1 1/ /2-2/2 G2-2 1/ /2 M5 - G1/ /2 G1/8-1/ /2-4/3 G1/8-1/ /2-4/3 G1/8-1/4-3/ /2-4/3 G1/4-3/ /2-4/3 G1/4-3/8-1/ /2-4/3 G3/8-1/2-3/ /2-4/3 G3/ /2-4/3 G3/ /4-1 1/ /2 M /2-5/3 G1/8-1/ /2-5/3 G1/ /2-5/3 G1/4-3/ ISO 1 5/2-5/3 G3/8-1/ ISO 2 5/2-5/3 G1/2-3/ ISO 3

10 Direct solenoid and solenoid pilot operated valves Flow (Max) Function Port size Nl/min Circuit bar mounting Series cylinder ports in base with pressure regulators "plug-in" "plug-in" with pressure regulators "plug-in" with flow regulators "plug-in" with pressure and flow regulators cylinder ports in valve with shut-off valve 3/2-2/2 M /2-2/2 G1/ /2-2/2 G1/8-1/ /2-2/2 G1/8-1/ /2-2/2 G1/8-1/ /2-2/2 G1/4-3/ /2-2/2 G3/8-1/2-3/ /2-2/2 G1/2-3/ /2-2/2 G1-1 1/4-1 1/ /2-2/2 G2-2 1/ /2 M5 - G1/ /2 G1/8-1/ /2-4/3 G1/8-1/ /2-4/3 G1/8-1/4-3/ /2-4/3 G1/4-3/ /2-4/3 G1/4-3/8-1/ /2-4/3 G3/8-1/2-3/ /2-4/3 G3/ /2-4/3 G3/ /4-1 1/ /2 M /2-5/3 G1/8-1/ /2-5/3 G1/ /2-5/3 G1/4-3/ ISO 1 5/2-5/3 G3/8-1/ ISO 2 5/2-5/3 G1/2-3/ ISO 3

11 R e m o t e a i r v a l v e s Flow (Max) Function Port size Nl/min Individual mounting Manifold mounting Circuit bar mounting Series Inline sub-base stacking sub-base cylinder ports in valve with shut-off valve 3/2-2/2 G1/8-1/ /2-2/2 G1/4-3/ /2-2/2 G3/8-1/2-3/ /2-2/2 G1/2-3/ /2-2/2 G1-1 1/4-1 1/ /2-2/2 G2-2 1/ /2 G1/8-1/ /2-4/3 G1/8-1/ /2-4/3 G1/8-1/4-3/ /2-4/3 G1/4-3/ /2-4/3 G1/4-3/8-1/ /2-4/3 G3/8-1/2-3/ /2-4/3 G3/ /2-4/3 G3/ /4-1 1/ /2-5/3 G1/ /2-5/3 G1/4-3/ ISO 1 5/2-5/3 G3/8-1/ ISO 2 5/2-5/3 G1/2-3/ ISO 3

12 Mechanically and manually operated valves Flow (Max) Function Port size Nl/min Individual mounting Manifold mounting Circuit bar mounting Series Inline sub-base cylinder ports in valve 3/2-2/2 G1/8-1/ /2-5/3 G1/

13 B a s e s a c c o r d i n g t o I S O ISO 1 ISO 2 ISO 3 ISO 1 ISO 2 ISO 3

14 P r e s s u r e r e g u l a t o r s Manual adjust Series Single regulator Single pressure Single regulator Dual pressure Dual regulator Dual pressure A B A B A B A B A B A B EXH A EXH B EXH EXH EXH EXH PR82A PR62C PR63C PR65B Single regulator Single pressure Single regulator Dual pressure Dual regulator Dual pressure PRA1A PRA2C PRA3B

15 P r e s s u r e r e g u l a t o r s Air adjust Series Single regulator Single pressure Single regulator Dual pressure Dual regulator Dual pressure A B A B A B A B A B A B EXH A EXH B EXH EXH EXH EXH PR82A PR62C PR63C PR65B Single regulator Single pressure Single regulator Dual pressure Dual regulator Dual pressure PRA1A PRA2C PRA3B

16 P r e s s u r e c o n t r o l s y s t e m s PMPP MPP PPC5A PMPP MPP PPC5A

17 Direct solenoid and solenoid pilot operated valves Series 34 Individual mounting inline Circuit bar mounting cylinder ports in base cylinder ports in valve

18 Direct solenoid and solenoid pilot operated valves Series 34 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC M5 100 Nl/min inline OPERATIONAL BENEFITS mm valve, direct solenoid operated. 2. Balanced poppet, immune to variations of pressure. 3. Short stroke with high flow. 4. The patended solenoid develops high shifting forces. 5. Powerful return spring. 6. Flow is specifically adjusted on each valve. 7. Manual operator standard on all valves. HOW TO ORDER Reset 34A-xxx-Gxxx-xxx Port size M5 Universal valve NC only valve 2 2 Pressure range : 0 to 8,5 bar Pressure range : vacuum A-ABA-GXXX-XXX 34A-BBA-GXXX-XXX A-ABB-GXXX-XXX 34A-BBB-GXXX-XXX SOLENOID OPERATOR G XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection DC 24V=/1,8W A 45 cm 1 Non-locking KA Mini connector DD 24V=/2,5W C 92 cm KT Mini connector with light DF 24V=/4W x Other Options BA Flying leads xx Other Options BT xx Flying leads with light Other Options

19 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 34 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : (with 4 W coil) Note : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 1.8 mm 4 W : 100 Nl/min (C v 0.1) W : 80 Nl/min (C v 0.08) W : 60 Nl/min (C v 0.06) 50 cm 3 /min Epoxy encapsulated - 100% ED -15% to +10% of nominal voltage IP 54 4 W W W Energize : 3.4 ms De-energize : 1.5 ms Valve and coil are not interchangeable. DIMENSIONS 31,5 3,3 DIA. MTG. HOLES TYP. (2) C L C L C L 50,2 9,3 20,0 12,0 4, ,25 14,25 3 5,3 0,8 5,0 7,0 10,0 10,0 20,0

20 Direct solenoid and solenoid pilot operated valves Series 34 Function Port size Flow (Max) Circuit bar mounting 3/2 NO-NC, 2/2 NO-NC M5 80 Nl/min cylinder ports in base OPERATIONAL BENEFITS mm valve, direct solenoid operated. 2. Balanced poppet, immune to variations of pressure. 3. Short stroke with high flow. 4. The patended solenoid develops high shifting forces. 5. Powerful return spring. 6. Flow is specifically adjusted on each valve. 7. Manual operator standard on all valves. HOW TO ORDER Reset 34A-xxx-Gxxx-xxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Port size (see base) Universal valve 2 NC only valve 2 Pressure range : 0 to 8,5 bar Pressure range : vacuum A-L00-GXXX-XXX 34A-M00-GXXX-XXX 34A-N00-GXXX-XXX SOLENOID OPERATOR G XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection DC 24V=/1,8W A 45 cm 1 Non-locking KA Mini connector DD 24V=/2,5W C 92 cm KT Mini connector with light DF 24V=/4W x Other Options BA Flying leads xx Other Options BT xx Flying leads with light Other Options HOW TO ORDER CIRCUIT BAR** Port size EBP34A-xxxx-xx Side cylinder ports Bottom cylinder ports M5 EBP34A-001D-XX EBP34A-002D-XX * * Other options available. Consult factory. XX = Number of stations (03=3 stations) Note : click for valves mounted on base at the factory (add - 9 to the model number).

21 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 34 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : (with 4 W coil) Note : Spare parts : Options : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 1.8 mm 4 W : 80 Nl/min (C v 0.08) - 2,5 W : 60 Nl/min (C v 0.06) - 1,8 W : 40 Nl/min (C v 0.04) 50 cm 3 /min Epoxy encapsulated - 100% ED -15% to +10% of nominal voltage IP 54 4 W W W Energize : 3.4 ms De-energize : 1.5 ms Valve and coil are not interchangeable. Seal between valve and bar (x3) : Mounting screw (x2) : Blanking plate : M Isolation of inlet and/or exhaust. DIMENSIONS G1/8 PORTS 1 & 3 EACH END 59,0 52,0 C L C L C L 2 1 6,0 22,0 12,5 3 7,5 2,0 10,5 18,0 4,5 4,0 14,5 12,5 14,0 34,0 18,0 34,0 OPTIONAL BOTTOM PORTS 18,0 4,5 4,2 DIA. MOUNTG HOLES 4,0

22 Direct solenoid and solenoid pilot operated valves Series 34 Function Port size Flow (Max) Circuit bar mounting 3/2 NO-NC, 2/2 NO-NC M5 80 Nl/min cylinder ports in valve OPERATIONAL BENEFITS mm valve, direct solenoid operated. 2. Balanced poppet, immune to variations of pressure. 3. Short stroke with high flow. 4. The patended solenoid develops high shifting forces. 5. Powerful return spring. 6. Flow is specifically adjusted on each valve. 7. Manual operator standard on all valves. HOW TO ORDER Reset 34A-xxx-Gxxx-xxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Port size M5 Universal valve NC only valve 2 2 Pressure range : 0 to 8,5 bar Pressure range : vacuum A-ABA-GXXX-XXX 34A-BBA-GXXX-XXX A-ABB-GXXX-XXX 34A-BBB-GXXX-XXX SOLENOID OPERATOR G XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection DC 24V=/1,8W A 45 cm 1 Non-locking KA Mini connector DD 24V=/2,5W C 92 cm KT Mini connector with light DF 24V=/4W x Other Options BA Flying leads xx Other Options BT xx Flying leads with light Other Options HOW TO ORDER CIRCUIT BAR** EBM34A-xxxx-xx Port size M5 EBM34A-001D-XX * * Other options available. Consult factory. XX = Number of stations (03=3 stations) Note : click for valves mounted on base at the factory (add - 9 to the model number).

23 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 34 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : (with 4 W coil) Note : Spare parts : Options : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 1.8 mm 4 W : 80 Nl/min (C v 0.08) W : 60 Nl/min (C v 0.06) - 1,8 W : 40 Nl/min (C v 0.04) 50 cm 3 /min Epoxy encapsulated - 100% ED -15% to +10% of nominal voltage IP 54 4 W W W Energize : 3.4 ms De-energize : 1.5 ms Valve and coil are not interchangeable. Seal between valve and bar (x3) : Mounting screw (x2) : Blanking plate : A. Isolation of inlet and/or exhaust. DIMENSIONS 19,0 2 B 1 3 A G D 10,5 E 14,0 F C 38,5 Port size A B C D E F G G1/8 16,0 47,5 57,4 8,0 23,0 31,0 8,0 M5 12,0 43,5 51,5 9,0 18,0 26,0 6,0

24 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection VALVE CODE - G XX X - 1 XX OPTIONS AVAILABLE FOR - solenoid valves 34 & 44 Series

25 OPTIONS Back 1. VOLTAGE (type 34 Series) -G XX X - 1 XX VOLTAGE DC 24 V=/1,8 W DD 24 V=/2,5 W DE 24 V=/3,0 W DF 24 V=/4,0 W DJ 12 V=/1,8 W DK 12 V=/2,5 W DM 12 V=/3,0 W DN 12 V=/4,0 W ED 120 V~/50 Hz (2,5 W) 1. VOLTAGE (type 44 Series) -G XX X - 1 XX VOLTAGE DA 24 V=/1,0 W DC 24 V=/1,8 W DD 24 V=/2,5 W DF 24 V=/4,0 W DG 12 V=/1,0 W DJ 12 V=/1,8 W DK 12 V=/2,5 W DN 12 V=/4,0 W ED 120 V~/50 Hz (2,5 W) 2. WIRE LENGTH (Common options for 34 & 44 Series) -G XX X - 1 XX WIRE LENGTH A 45 cm - 18 B 60 cm - 24 C 90 cm - 36 D 120 cm - 48 E 180 cm - 72 F 240 cm - 96 G 305 cm H 366 cm - 144

26 O p t i o n s OPTIONS Back 3. MANUAL OPERATOR -G XX X - 1 XX MANUAL OPERATOR 1 Non-locking recessed 4. ELECTRICAL CONNECTION -G XX X - 1 XX NO CONNECTOR BA Flying leads BB BA with ground wire BC BA with light BD BA with light and ground wire BE BA with suppression diode BF BA with suppression diode and ground wire BG BA with suppression diode and light BH BA with suppression diode, light and ground wire BN BA with suppression diode and blocking diode BP BA with suppression diode, blocking diode and ground wire BR BA with suppression diode, blocking diode and light BS BA with suppression diode, blocking diode, light and ground wire BT BA with light BU BA with light and ground wire BV BA with suppression diode and light BW BA with suppression diode, light and ground wire BX BA with suppression diode, blocking diode and light BY BA with suppression diode, blocking diode, light and ground wire -G XX X - 1 XX PLUG- CONNECTOR KA Mini connector with flying leads KB KA with ground wire KE KA with suppression diode KF KA with suppression diode and ground wire KJ Mini connector for KA option KM Mini connector for KB option KN KA with suppression diode and blocking diode KP KA with suppression diode, blocking diode and ground wire KT KA with light KU KA with light and ground wire KV KA with suppression diode and light KW KA with suppression diode, light and ground wire KX KA with suppression diode, blocking diode and light KY KA with suppression diode, blocking diode, light and ground wire

27 Direct solenoid and solenoid pilot operated valves Series 35 Individual mounting inline Manifold mounting stacking sub-base sub-base with pressure regulators Circuit bar mounting cylinder ports in base with pressure regulators "plug-in" "plug-in" with pressure regulators 1 2 3

28 Direct solenoid and solenoid pilot operated valves Series 35 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G1/8 150 Nl/min inline OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 35A-xxx-Dxxx-xxx Port size Universal valve NC only valve 2 2 G1/ A-ACA-DXXX-XXX A-ACB-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50Hz A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50Hz J Connector 2 Locking KD Square connector with light AC 24V~/50Hz x Other Options x Other Options JB Rectangular connector FB 24V=/1,8W JD Rectangular connector with light DA 24V=/5,4W BA Flying leads DF 24V=/12,7W xx Other Options xx Other Options

29 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 35 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 80 Nl/min (C v 0.08) to 12.7 W : 150 Nl/min (C v 0.15) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 35A-000-DXXX-XXX, including mounting screws Seal (between solenoid and valve body) : NPTF threads. High flow up to 250 Nl/min, according to wattage. DIMENSIONS 32,5 11,2 11,7 27,3 7, ,0 10,0 16,5 24,1 32,5 14,0 60,5

30 Direct solenoid and solenoid pilot operated valves Series 35 Function Port size Flow (Max) Manifold mounting 3/2 NO-NC, 2/2 NO-NC M5 - G1/8 160 Nl/min stacking OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 35A-xxx-Dxxx-xxx Port size NC only valve NO only valve CYL CYL G1/8 EXH 35A-SCC-DXXX-XXX EXH 35A-SCD-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50Hz A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50Hz J Connector 2 Locking KD Square connector with light AC 24V~/50Hz x Other Options x Other Options BA Flying leads FB 24V=/1,8W xx Other Options DA 24V=/5,4W DF 24V=/12,7W xx Other Options End plate kit (Port size G1/4 ) : M P Note : upon request, manifolds are mounted at the factory.

31 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 35 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 120 Nl/min (C v 0.12) to 12.7 W : 160 Nl/min (C v 0.16) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 35A-000-DXXX-XXX, including mounting screws Seal (between solenoid and valve body) : Pressure seal (between valves) : Tie-rod (x2) : NPTF threads. High flow up to 250 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS 6,5 DIA. 8,0 ±0,2 G1/8 (option) 22,0 7,5 NI NI 9,75 32,5 G1/4 + EX 54,5 CYL - N.C. CYL - N.C. 14,5 10,0 EX 16,5 24,0 9,75 G1/8 CYL 19,0 ±0,1 9,5 25,0 13,0 44,0

32 Direct solenoid and solenoid pilot operated valves Series 35 Function Port size Flow (Max) Manifold mounting 3/2 NO-NC, 2/2 NO-NC G1/8 100 Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 35A-xxx-Dxxx-xxx SIDE CYLDER PORTS Port size NC only valve NO only valve CYL CYL Valve less base M5 base G 1/8 base EXH 35A-B00-DXXX-XXX 35A-BDE-DXXX-XXX 35A-BCE-DXXX-XXX EXH 35A-B00-DXXX-XXX 35A-BDF-DXXX-XXX 35A-BCF-DXXX-XXX BOTTOM CYLDER PORTS Port size NC only valve NO only valve CYL CYL Valve less base M5 base G 1/8 base EXH 35A-B00-DXXX-XXX 35A-BJE-DXXX-XXX 35A-BHE-DXXX-XXX EXH 35A-B00-DXXX-XXX 35A-BJF-DXXX-XXX 35A-BHF-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50Hz A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50Hz J Connector 2 Locking KD Square connector with light AC 24V~/50Hz x Other Options x Other Options BA Flying leads FB 24V=/1,8W xx Other Options DA 24V=/5,4W DF 24V=/12,7W xx Other Options End plate kit (Port size : G1/4 ) : M P Note : upon request, manifolds are mounted at the factory.

33 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 35 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 90 Nl/min (C v 0.09) to 12.7 W : 100 Nl/min (C v 0.1) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 35A-000-DXXX-XXX, including mounting screws Seal (between solenoid and valve body) : Pressure seal (between valve and base) : Pressure seal (between bases) : Tie-rod (x2) : NPTF threads. High flow up to 180 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS OPTIONAL ISOLATOR 8,0 ± 0,4 6,5 OPTIONAL PRESSURE SENSG PORT 32.5 G1/4 LET & EXHAUST BOTH ENDS 2,5 10,0 5,0 EX 20,00 ± 0,1 23,5 12,0 16, ,8 22,5 9,5 26,0 OR M5 CYL. PORT 58,0 G1/8 CYL. PORTS 6,0 8,0 OPTION BOTTOM CYL. PORT CYL. NC CYL. NC 57,0 10,0 CYL. NC CYL. NC 14,0 6,0 8,0

34 Direct solenoid and solenoid pilot operated valves Series 35 Function Port size Flow (Max) Manifold mounting 3/2 NO-NC, 2/2 NO-NC M5 - G1/8 100 Nl/min sub-base with pressure regulators OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 35A-xxx-Dxxx-xxx SIDE CYLDER PORTS Port size NC only valve NO only valve CYL CYL Valve less base M5 base G 1/8 base EXH 35A-B00-DXXX-XXX 35A-BDJ-DXXX-XXX 35A-BCJ-DXXX-XXX EXH 35A-B00-DXXX-XXX 35A-BDK-DXXX-XXX 35A-BCK-DXXX-XXX BOTTOM CYLDER PORTS Port size NC only valve NO only valve CYL CYL Valve less base M5 base G 1/8 base EXH 35A-B00-DXXX-XXX 35A-BJJ-DXXX-XXX 35A-BHJ-DXXX-XXX EXH 35A-B00-DXXX-XXX 35A-BJK-DXXX-XXX 35A-BHK-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50Hz A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50Hz J Connector 2 Locking KD Square connector with light AC 24V~/50Hz x Other Options x Other Options BA Flying leads FB 24V=/1,8W xx Other Options DA 24V=/5,4W DF 24V=/12,7W xx Other Options End plate kit (Port size : G1/4 ) : M P Note : upon request, manifolds are mounted at the factory.

35 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 35 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 90 Nl/min (C v 0.09) to 12.7 W : 100 Nl/min (C v 0.1) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 35A-000-DXXX-XXX, including mounting screws Seal (between solenoid and valve body) : Pressure seal (between valve and base) : Pressure seal (between bases) : Tie-rod (x2) : Pressure regulator : 35A-00M. NPTF threads. High flow up to 180 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS OPTIONAL ISOLATOR 8,0 ± 0,4 6,5 OPTIONAL PRESSURE SENSG PORT 32,5 G1/4 LET & EXHAUST 2,5 10,0 5,0 EX 20,00 ± 0,1 23,5 12,0 15,5 16, ,8 22,5 9, ,1 58,0 M5 CYL. PORT G1/8 CYL. PORTS 8,0 OPTIONAL BOTTOM CYL. PORT 6,0 CYL. NC CYL. NC 57,0 10,0 CYL. NC CYL. NC 15,5 LOCK 14,0 6,0 8,0 ADJ. LOCKG KNOB

36 Direct solenoid and solenoid pilot operated valves Series 35 Function Port size Flow (Max) Circuit bar mounting 3/2 NO-NC, 2/2 NO-NC M5 - G1/8 90 Nl/min cylinder ports in base OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 35A-xxx-Dxxx-xxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Universal valve CYL Valve less base EXH 35A-B00-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50Hz A 45 cm(flying leads) 1 Non-locking KA Square connector AA 110V~/50Hz J Connector 2 Locking KD Square connector with light AC 24V~/50Hz x Other Options x Other Options BA Flying leads FB 24V=/1,8W xx Other Options DA 24V=/5,4W DF 24V=/12,7W xx Other Options HOW TO ORDER CIRCUIT BAR** Port size G1/8 M5 EBM35A-xxxx-xx Side cylinder ports Spacing 21 mm EBM35A-001C-XX EBM35A-001D-XX Bottom cylinder ports Spacing 21 mm EBM35A-002C-XX EBM35A-002D-XX * * Other options available. Consult factory. XX = Number of stations (03=3 stations) Note : click for valves mounted on base at the factory (add - 9 to the model number).

37 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 35 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 80 Nl/min (C v 0.08) to 12.7 W : 90 Nl/min (C v 0.09) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 35A-000-DXXX-XXX including mounting screws Seal (between solenoid and valve body) : Pressure seal (between valve and bar) : Blanking plate : M NPTF threads. High flow up to 170 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS VALVE BLANKG PLATE 21,0 "A" 21,0 5,2 DIA. 2 MTG. HOLES D 7,0 21,0 5,0 OPTIONAL BOTTOM PORTS 5,0 29, ,0 B 64,5 26,3 32,5 SPACG SIZE A STANDARD FOR JB 21,0 26,0 50,5 22,0 11,5 SPACG SIZE G1/8 M5 B 8,0 5,5 D 24,5 24,2 17,0 32,0 40,0 G1/8 2 PORTS BOTH ENDS

38 Direct solenoid and solenoid pilot operated valves Series 35 Function Port size Flow (Max) Circuit bar mounting 3/2 NO-NC, 2/2 NO-NC M5 - G1/8 90 Nl/min with pressure regulators OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 35A-xxx-Dxxx-xxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Universal valve CYL Valve less base EXH 35A-B00-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50Hz A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50Hz J Connector 2 Locking KD Square connector with light AC 24V~/50Hz x Other Options x Other Options BA Flying leads FB 24V=/1,8W xx Other Options DA 24V=/5,4W DF 24V=/12,7W xx Other Options HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY)* * Port size Side cylinder ports M5 G1/8 EBM35A-xxxx-xx Spacing 26 mm EBM35A-013D-XX EBM35A-013C-XX Spacing 40 mm (with gauge port) EBM35A-023D-XX EBM35A-023C-XX Port size Bottom cylinder ports M5 G1/8 Spacing 26 mm EBM35A-014D-XX EBM35A-014C-XX Spacing 40 mm (with gauge port) EBM35A-024D-XX EBM35A-024C-XX * * Other options available. Consult factory. XX = Number of stations (03=3 stations) Note : click for valves mounted on base at the factory (add - 9 to the model number).

39 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 35 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 80 Nl/min (C v 0.08) to 12.7 W : 90 Nl/min (C v 0.09) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 35A-000-DXXX-XXX, including mounting screws Seal (between solenoid and valve body) : Pressure seal (between valve and base) : Blanking plate valve : M Blanking plate regulator : M Pressure regulator : 35A-00M. NPTF threads. High flow up to 170 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS VALVE BLANKG PLATE B 5 5 5,2 DIA 2 MTG. HOLES 21,0 "A" 21, , /8 2 PORTS BOTH ENDS REGULATOR BLANKG PLATE 8,0 58,3 5,0 20,1 32,5 47,5 SPACG SIZE A STANDARD 21,0 56,5 FOR JB 26,0 28,0 17,75 14,0 16,0 PORT SIZE G1/8 M5 B 15,5 18,0 OPTIONAL BOTTOM PORTS 10,5 25,5 40,0 91,1

40 Direct solenoid and solenoid pilot operated valves Series 35 Function Port size Flow (Max) Circuit bar mounting 3/2 NO-NC, 2/2 NO-NC M5 - G1/8 90 Nl/min "plug-in" OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 35A-xxx-DxxJ-xFM HOW TO ORDER VALVE FOR "PLUG-" CIRCUIT BAR Universal valve CYL Valve less base EXH 35A-B00-DXXJ-XFM SOLENOID OPERATOR D XX J- X FM * XX Voltage X Manual operator AB AA AC FB DA DF xx 220V~/50Hz 110V~/50Hz 24V~/50Hz 24V=/1,8W 24V=/5,4W 24V=/12,7W Other Options 1 Non-locking 2 Locking x Other Options HOW TO ORDER "PLUG-" CIRCUIT BAR ** ECD35A-xxxx-xx-xx Port size Spacing mm Side cylinder ports Bottom cylinder ports M5 21 ECD35A-001D-A0-XX* ECD35A-002D-A0-XX* G1/8 21 ECD35A-001C-A0-XX* ECD35A-002C-A0-XX* * without light (AO) XX = Number of stations (03=3 stations) * with light 240V~/50 Hz (AB) * with light 24V= (AD) * * Other options available. Consult factory. Note : for valves mounted on base at the factory (add - 9 to the model number).

41 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 35 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 80 Nl/min (C v 0.08) to 12.7 W : 90 Nl/min (C v 0.09) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA DC : 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 35A-000-DXXJ-XFM including mounting screws Seal (between solenoid and valve body) : Pressure seal (between valve and bar) : Blanking plate : M NPTF threads. High flow up to 170 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS VALVE BLANKG PLATE 21,0 21,0 21,0 22,8 61,0 5, ,5 47, ,0 19,8 17,0 20, ,5 5,0 37,0 G1/8 PORTS 1 & 3 EACH END 29,0 57,3 1" NPSM EACH END 4,5 78,0 84,8 2 4,5 5,2 DIA. (2) MOUNTG HOLES 37,0

42 Direct solenoid and solenoid pilot operated valves Series 35 Function Port size Flow (Max) Circuit bar mounting 3/2 NO-NC, 2/2 NO-NC M5 - G1/8 90 Nl/min "plug-in" with pressure regulators OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 35A-xxx-DxxJ-xFM HOW TO ORDER VALVE FOR "PLUG-" CIRCUIT BAR Universal valve CYL Valve less base EXH 35A-B00-DXXJ-XFM SOLENOID OPERATOR D XX J- X FM * XX Voltage X Manual operator AB AA 220V~/50Hz 110V~/50Hz 1 Non-locking 2 Locking AC 24V~/50Hz x Other Options FB 24V=/1,8W DA 24V=/5,4W DF 24V=/12,7W xx Other Options HOW TO ORDER "PLUG-" CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY)* * Port size ECD35A-xxxx-xx-xx Spacing mm Bottom cylinder ports M5 G1/ ECD35A-004D-A0-XX* ECD35A-004C-A0-XX* * without light (AO) XX = Number of stations (03=3 stations) * with light 240V~/50Hz (AB) * with light 24V= (AD) * * Other options available. Consult factory. Note : click for valves mounted on base at the factory (add - 9 to the model number).

43 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 35 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 80 Nl/min (C v 0.08) to 12.7 W : 90 Nl/min (C v 0.09) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 35A-000-DXXJ-XFM including mounting screws Seal (between solenoid and valve body) : Pressure seal (between valve and bar) : Blanking plate valve : E054. Blanking plate regulator : M Pressure regulator : 35A-00M. NPTF threads. High flow up to 170 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS VALVE BLANKG PLATE 21,0 21,0 21,0 22,8 61,0 5,1 17,0 68,5 47, ,0 19,8 17,0 20,0 40,0 13,5 5,0 37,0 G1/8 PORTS 1 & 3 EACH END 29,0 57,3 1" NPSM EACH END 4,5 78,0 84, ,4 51,0 4,5 20,7 5,2 DIA. (2) MOUNTG HOLES 37,0

44 O p t i o n s OPTIONS Codification table for voltages / Wire length / Manual operators / Electrical connections VALVE CODE - D XX X - X XX OPTIONS AVAILABLE FOR - Solenoid valves 35 & 45 Series - Pilot operated valves with pilots type 35 Series Series : 82

45 OPTIONS Back 1. VOLTAGE - D XX X - X XX VOLTAGE AA 120 V~/60 Hz V/50 Hz AB 240 V~/60 Hz V/50 Hz AC 24 V~/60 Hz - 24 V/50 Hz AD 24 V~/60 Hz AE 200 V~/60 Hz AF 240 V~/50 Hz AG 240 V~/50 Hz DA 24 V=/5,4 W DB 12 V=/5,4 W DC 12 V=/7,5 W DD 24 V=/7,3 W DE 12 V=/12,7 W CLSF DF 24 V=/12,7 W CLSF DK 110 V=/4,7 W DL 64 V=/6 W DM 36 V=/5,3 W DN 6 V=/6 W DP 48 V=/5,8 W DU 24 V=/6 W EA 12 V=/6 W FA 12 V=/1,8 W FB 24 V=/1,8 W FE 12 V=/2,4 W FF 24 V=/2,4 W 2. WIRE LENGTH - D XX X - X XX WIRE LENGTH A 45 cm - 18 B 60 cm - 24 C 90 cm - 36 D 120 cm - 48 E 180 cm - 72 F 240 cm - 96 J For external plug-in connector P For plug-in valves (82 Series only)

46 O p t i o n s OPTIONS Back 3. MANUAL OPERATOR - D XX X - X XX MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 4. ELECTRICAL CONNECTION - D XX X - X XX ELECTRICAL CONNECTION BA Flying leads BK BA with protection diode BL BA with protection varistor CA 1/2" NPS conduit JB Rectangular connector JD Rectangular connector with light JM Rectangular connector, male only KA Square connector KB Square connector with protection diode KC Square connector with protection varistor KD Square connector with light KE Square connector with light and protection diode KF Square connector with light and protection varistor KJ Square connector (male only) KK Square connector with protection diode (male only) KL Square connector with protection varistor (male only) MA Electrical common conduit TA Dual tabs TB TA with protection diode TD TA with light TE TA with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode DA* Plug-in connector DK* DA with protection diode DL* DA with protection varistor * To be used with 82 Series only

47 Direct solenoid and solenoid pilot operated valves Series 100 Individual mounting inline Manifold mounting stacking sub-base Circuit bar mounting cylinder ports in base 2 CYL 1 N.C. 3 N.O.

48 Direct solenoid and solenoid pilot operated valves Series 100 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G1/8 - G1/4 180 Nl/min inline OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset xxxx-xxyzz Port size Universal valve NC only valve 2 2 G1/8 G1/ B-XXYZZ 117B-XXYZZ B-XXYZZ 167B-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options

49 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 100 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +60 C 2 mm 180 Nl/min (C v 0.18) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA Holding : 10.9 VA = 1 to 17 W 24 V=/8.5 W Energize : 7 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 4 W) : D1-XXYZZ, including mounting screws and seal NPTF threads. DIMENSIONS 89,0 24,6 72,4 Ø 5 mm 56,0 16,8 #2 #1 17,8 ~48 F G #3 C D 4, H 24,9 ø 18 B 21,2 A Ø 4,4 mm 22,2 33,0 PORT SIZE A B C D E F G H G1/8 28,4 12,7 14,0 8,0 40,1 64,9 60,1 23,2 G1/4 29,8 13,3 12,7 9,9 40,9 65,8 60,9 24,1

50 Direct solenoid and solenoid pilot operated valves Series 100 Function Port size Flow (Max) Manifold mounting 3/2 NO-NC, 2/2 NO-NC G1/8 - G1/4 180 Nl/min stacking OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset xxxx-xxyzz Port size Universal valve NC only valve 2 2 G1/8 G1/ B-XXYZZ 187B-XXYZZ B-XXYZZ 189B-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz 59 24V=/2,5W y Other Options BA zz Flying leads (45 cm) Other Options 87 24V=/17,1W 61 24V=/8,5W xx Other Options End plate kit (Port size G1/4 ) : M P

51 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 100 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +60 C 2 mm 180 Nl/min (C v 0.18) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush 14.8 VA Holding : 10.9 VA DC : 1 to 17.1 W 24 V=/8.5 W Energize : 7 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Function plate : N Tie-rod (x2) : NPTF threads. Isolation of inlet and/or exhaust. DIMENSIONS 56,0 16,8 64,2 ~48,0 27,4 10,4 19,0 21,6 EXH 17,0 NO CYL CYL NC NO 25,4 44,0 G1/4 LET & EXHAUST PORTS EACH END ø 18,0 13,0 5,2 24,8 ± 0,2 ± 0,1 12,7 CYL. PORT G1/8 OR G1/4 8,2 ± 0,2 MT G SLOT Ø 6,6 mm 22,0 33,7 G1/8 - OPTIONAL BOTTOM LET PORTS 7,9 ± 0,2

52 Direct solenoid and solenoid pilot operated valves Series 100 Function Port size Flow (Max) Manifold mounting 3/2 NO-NC, 2/2 NO-NC G1/8 140 Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset xxxx-xxyzz Port size Universal valve NC only valve 2 2 Valve less base G 1/8 base B-XXYZZ 136B-XXYZZ B-XXYZZ 176B-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz 59 24V=/2,5W y Other Options BA zz Flying leads (45 cm) Other Options 87 24V=/17,1W 61 24V=/8,5W xx Other Options End plate kit ( Port size : G1/4 ) : A P

53 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 100 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +60 C 2 mm 140 Nl/min (C v 0.14) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA Holding : 10.9 VA = 1 to 17 W 24 V=/8.5 W Energize : 7 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 4 W) : D1-XXYZZ, including mounting screws and seal Function plate : A Seal between manifold bases : Tie-rod (x2) : NPTF threads. Isolation of inlet and/or exhaust. DIMENSIONS G1/8 CYL. PORT 56,0 30,1 17,6 CYL 59,5 14,2 25,4 ± 0,1 EXH 12,7 17,8 9,7 ± 0,2 2,3 4,8 OPTIONAL G1/8 BOTTOM PORTS 11,4 25,4 63,5 66,9 G1/4 LET & EXHAUST PORTS EACH END 31,5 CYL 15,7 32,7 46,6 MT G SLOT Ø 6,6 mm EXH 5,7

54 Direct solenoid and solenoid pilot operated valves Series 100 Function Port size Flow (Max) Circuit bar mounting 3/2 NO-NC, 2/2 NO-NC G1/8 150 Nl/min cylinder ports in base OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset xxxx-xxyzz HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Universal valve NC only valve 2 2 Valve less base B-XXYZZ B-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz 59 24V=/2,5W y Other Options BA zz Flying leads (45 cm) Other Options 87 24V=/17,1W 61 24V=/8,5W xx Other Options HOW TO ORDER CIRCUIT BAR** EBM10-xxxx-xx Port size Spacing Side cylinder ports Bottom cylinder ports G1/8 26 mm EBM10-011C-XX EBM10-012C-XX G1/8 40 mm EBM10-021C-XX EBM10-022C-XX * * Other options available. Consult factory. XX = Number of stations (03=3 stations) Note : click for valves mounted on base at the factory (add -9 to the model number).

55 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 100 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +60 C 2 mm 150 Nl/min (C v 0.15) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush 14.8 VA Holding : 10.9 VA = 1 to 17 W 24 V=/8.5 W Energize : 7 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 4 W) : D1-XXYZZ, including mounting screws and seal Function plate : A Blanking plate : E144. NPTF threads. Isolation of inlet and/or exhaust. DIMENSIONS 56,0 30,1 21,0 26,0 56,0 22,0 8,5 8,0 23,0 G1/8 2 PORTS BOTH ENDS Ø 5,2 G1/8 74,0

56 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

57 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

58 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

59 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

60 Direct solenoid and solenoid pilot operated valves Series 200 Individual mounting inline Manifold mounting sub-base sub-base with pressure regulators 2 CYL 1 N.C.

61 Direct solenoid and solenoid pilot operated valves Series 200 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G1/8 - G1/4 500 Nl/min inline OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset xxxx-xxyzz Mod 005 Port size Universal valve NC only valve 2 2 G1/8 G1/ B-XXYZZ Mod B-XXYZZ Mod B-XXYZZ Mod B-XXYZZ Mod 005 SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JA Square connector V~/50Hz 2 Locking JC Square connector with light 22 24V~/50Hz y Other Options BA Flying leads (45 cm) 52 24V=/2,5W zz Other Options 78 24V=/24W 61 24V=/8,5W xx Other Options

62 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 200 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +60 C 4.8 mm 500 Nl/min (C v 0.5) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 33 VA Holding : 19.7 VA = 1 to 24 W 24 V=/8.5 W Energize : 15 ms De-energize : 5 ms 50Hz/6 W Energize : 3-8 ms De-energize : 3-13 ms Spare parts : Options : Solenoid operator (power 6 W) : D4-XXYZZ, including mounting screws and seal B NPTF threads. Explosion-proof model. DIMENSIONS 45,2 44,4 90,5 98,4 5,1 DIA. 2 MTG HOLES ~28 17,4 27, ,9 38,7 11,1 34,6

63 Direct solenoid and solenoid pilot operated valves Series 200 Function Port size Flow (Max) Manifold mounting 3/2 NO-NC, 2/2 NO-NC G1/8 - G1/4 450 Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset xxxx-xxyzz Port size Universal valve NC only valve CYL CYL Valve less base G 1/8 base G 1/4 base EXH 250B-XXYZZ 256B-XXYZZ Mod B-XXYZZ Mod 005 EXH 280B-XXYZZ 286B-XXYZZ Mod B-XXYZZ Mod 005 SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JC Square connector with light V~/50Hz 2 Locking JA Square connector 22 24V~/50Hz 52 24V=/2,5W y Other Options BA zz Flying leads (45 cm) Other Options 78 24V=/24W 61 24V=/8,5W xx Other Options End plate kit (Port size : G1/4 ) : A P

64 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 200 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +60 C 4.8 mm 450 Nl/min (C v 0.45) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 33 VA Holding : 19.7 VA = 1 to 24 W 24 V=/8.5 W Energize : 15 ms De-energize : 5 ms 50Hz/16 W Energize : 3-8 ms De-energize : 3-13 ms Spare parts : Options : Solenoid operator (power 6 W) : D4-XXYZZ, including mounting screws and seal B Function plate : A Seal between bases : B Tie-rod (x2) : B NPTF threads. Explosion-proof model. Isolation of inlet and/or exhaust. DIMENSIONS G1/8 OR G1/4 CYL PORT ~28,0 42,0 75,7 29,5 17,5 14,5 19,2 CYL 35,1 75,8 EXH 102,1 G1/4 LET & EXH. PORTS EACH END 18,0 20,1 9,7 22,9 45,9 EXH 12,7 12,7 OPTIONAL G1/8 OR G1/4 BOTTOM PORTS 20,1 35,6 CYL 39,4 52,1 MT G SLOT 8,1 DIA. MAX.

65 Direct solenoid and solenoid pilot operated valves Series 200 Function Port size Flow (Max) Manifold mounting 3/2 NO-NC, 2/2 NO-NC G1/8 - G1/4 400 Nl/min sub-base with pressure regulators OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset xxxx-xxyzz Port size Universal valve NC only valve CYL CYL Valve less base G 1/4 base 250B-XXYZZ EXH 252B-XXYZZ Mod B-XXYZZ EXH 282B-XXYZZ Mod 005 SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JA Square connector V~/50Hz 2 Locking JC Square connector with light 22 24V~/50Hz 52 24V=/2,5W y Other Options BA zz Flying leads (45 cm) Other Options 78 24V=/24W 61 24V=/8,5W xx Other Options Manifold fastening kit : N-02003

66 % 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 200 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +60 C 4.8 mm 400 Nl/min (C v 0.40) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 33 VA Holding : 19.7 VA = 1 to 24 W 24 V=/8.5 W Energize : 15 ms De-energize : 5 ms 50Hz/16 W Energize : 3-8 ms De-energize : 3-13 ms Spare parts : Options : Solenoid operator (power 6 W) : D4-XXYZZ, including mounting screws and seal B Function plate : A Seal between bases (x2) : Tie-rod (x2) : B Pressure regulator : PR82A-J0AA. NPTF threads. Explosion-proof model. Isolation of inlet and/or exhaust. DIMENSIONS ,4 ~28 13,5 17,5 20,5 Ø 6,7 mm MTG HOLE 19 G1/8 GAGE PORT 118,5 51, ,0 CYL CYL CYL L O C K L O C K L O C K 21,5 7,5 15,0 22,5 46,0

67 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

68 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

69 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

70 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

71 Direct solenoid and solenoid pilot operated valves Series 52 Individual mounting inline Circuit bar mounting cylinder ports in base cylinder ports in valve 2 3 1

72 Direct solenoid and solenoid pilot operated valves Series 52 Function Port size Flow (Max) Individual mounting 3/2 NO-NC G1/8 - G1/ Nl/min inline OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways. 2. Memory spring available. 3. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow, short and consistent response times. 7. Wiping effect eliminates sticking. 8. Long service life. HOW TO ORDER Reset 52A-xx-xxx-DM-Dxxx-xxx Port size Pilot air Single operator NO valve NC valve Double operator NO valve NC valve G1/8 Internal A-31-COA-DM-DXXX-XXX A-11-COA-DM-DXXX-XXX A-41-COA-DM-DXXX-XXX A-21-COA-DM-DXXX-XXX G1/4 52A-31-DOA-DM-DXXX-XXX 52A-11-DOA-DM-DXXX-XXX 52A-41-DOA-DM-DXXX-XXX 52A-21-DOA-DM-DXXX-XXX G1/8 External 52A-31-COB-DM-DXXX-XXX 52A-11-COB-DM-DXXX-XXX 52A-41-COB-DM-DXXX-XXX 52A-21-COB-DM-DXXX-XXX G1/4 52A-31-DOB-DM-DXXX-XXX 52A-11-DOB-DM-DXXX-XXX 52A-41-DOB-DM-DXXX-XXX 52A-21-DOB-DM-DXXX-XXX SOLENOID OPERATOR DM-D XX X - X XX * XX Voltage X Wire length X Manual operator XX Electrical connection JA 110V~/50Hz A 45 cm (Flying leads) 1 Non-locking KA Square connector JB 220V~/50Hz J Connector 2 Locking KD Square connector with light JC 24V~/50Hz x Other Options x Other Options JB Rectangular connector DA 24V=/5,4W JD Rectangular connector with light FB 24V=/1,8W BA Flying leads DF 24V=/12,7W xx Other Options xx Other Options O P T I O N S 52A-31-COA-DM-DXXX-XXX click for memory spring (replace by 4).

73 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 52 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : 1.4 to 8.5 bar External pilot : vacuum to 8.5 bar 1.4 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7.3 mm 1500 Nl/min (C v 1.5) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms 50Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms Pilot valve : DM-DXXX-XXX, including mounting screws and seal NPTF threads. DIMENSIONS 3,25 DIA. MTG. HOLES, TYP. (2) 96,0 61,0 18,7 15,5 9, ,75 44,0 39,0 32,0 20,5 17,0 62,5 24,5 5,0 4,25 DIA. MTG. HOLES, TYP. (2) 21,0 10,5 27,0 47,

74 Direct solenoid and solenoid pilot operated valves Series 52 Function Port size Flow (Max) Individual mounting 3/2 NO-NC G1/8 - G1/ Nl/min cylinder ports in base OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways. 2. Memory spring available. 3. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow, short and consistent response times. 7. Wiping effect eliminates sticking. 8. Long service life. HOW TO ORDER Reset 52A-xx-xxx-DM-Dxxx-xxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Pilot air Single operator Double operator NO valve NC valve NO valve NC valve Internal 52A-33-OOA-DM-DXXX-XXX 52A-13-OOA-DM-DXXX-XXX 52A-43-OOA-DM-DXXX-XXX 52A-23-OOA-DM-DXXX-XXX External 52A-33-OOC-DM-DXXX-XXX 52A-13-OOC-DM-DXXX-XXX 52A-43-OOC-DM-DXXX-XXX 52A-23-OOC-DM-DXXX-XXX SOLENOID OPERATOR DM-D XX X - X XX * XX Voltage X Wire length X Manual operator XX Electrical connection JA 110V~/50Hz A 45 cm (Flying leads) 1 Non-locking KA Square connector JB 220V~/50Hz J Connector 2 Locking KD Square connector with light JC 24V~/50Hz x Other Options x Other Options JB Rectangular connector DA 24V=/5,4W JD Rectangular connector with light FB 24V=/1,8W BA Flying leads DF 24V=/12,7W xx Other Options xx Other Options HOW TO ORDER CIRCUIT BAR ** CBP052A-xxxxx-xx Port size Pilot air Spacing standard 19,5 mm Spacing 26 mm (Rectangular connector) G1/8 Internal CBP052A-00AAB-XX CBP052A-02AAB-XX G1/4 CBP052A-00AAE-XX CBP052A-02AAE-XX G1/8 External CBP052A-00EAB-XX CBP052A-02EAB-XX G1/4 CBP052A-00EAE-XX CBP052A-02EAE-XX ** Other options available. Consult factory. XX = Number of stations (03=3 stations) O P T I O N S 52A-33-OOA-DM-DXXX-XXX click for memory spring (replace by 6).

75 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 52 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Accessories : Options : Compressed air, vacuum, inert gases Internal pilot : 1.4 to 8.5 bar External pilot : vacuum to 8.5 bar 1.4 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ - 18 C to + 50 C 7.3 mm 1200 Nl/min (C v. 1,2) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms 50Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms Pilot valve : DM-DXXX-XXX, including mounting screws and seal Blanking plate : M Seal (x3) : Mounting screw (x2) : NPTF threads. Isolation of inlet and/or exhaust. DIMENSIONS 25, ,5 19, , , ,0 36,0 96,0 32,0 102,3 23,2 21,0 10,0 10,0 14,5 29,0 51,5 G3/8" OPTIONAL G1/8" COMMON EXTERNAL PILOT 25,0

76 Direct solenoid and solenoid pilot operated valves Series 52 Function Port size Flow (Max) Circuit bar mounting 3/2 NO-NC G1/8 - G1/ Nl/min cylinder ports in valve OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways. 2. Memory spring available. 3. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow, short and consistent response times. 7. Wiping effect eliminates sticking. 8. Long service life. HOW TO ORDER Reset 52A-xx-xxx-DM-Dxxx-xxx SOLENOID OPERATOR Port size Pilot air Single operator NO valve NC valve Double operator NO valve NC valve G1/8 Internal A-31-COA-DM-DXXX-XXX A-11-COA-DM-DXXX-XXX A-41-COA-DM-DXXX-XXX A-21-COA-DM-DXXX-XXX G1/4 52A-31-DOA-DM-DXXX-XXX 52A-11-DOA-DM-DXXX-XXX 52A-41-DOA-DM-DXXX-XXX 52A-21-DOA-DM-DXXX-XXX G1/8 External 52A-31-COC-DM-DXXX-XXX 52A-11-COC-DM-DXXX-XXX 52A-41-COC-DM-DXXX-XXX 52A-21-COC-DM-DXXX-XXX G1/4 52A-31-DOC-DM-DXXX-XXX 52A-11-DOC-DM-DXXX-XXX 52A-41-DOC-DM-DXXX-XXX 52A-21-DOC-DM-DXXX-XXX SOLENOID OPERATOR DM-D XX X - X XX * XX Voltage X Wire length X Manual operator XX Electrical connection JA 110V~/50Hz A 45 cm (Flying leads) 1 Non-locking KA Square connector JB 220V~/50Hz J Connector 2 Locking KD Square connector with light JC 24V~/50Hz x Other Options x Other Options JB Rectangular connector DA 24V=/5,4W JD Rectangular connector with light FB 24V=/1,8W BA Flying leads DF 24V=/12,7W xx Other Options xx Other Options HOW TO ORDER CIRCUIT BAR ** CBM052A-xxxxx-xx Port size Pilot air Spacing standard 19,5 mm Spacing 26 mm (Rectangular connector) G3/8 Internal CBM052A-00AAB-XX CBM052A-02AAB-XX External CBM052A-00CAB-XX CBM052A-02CAB-XX ** Other options available. Consult factory. XX = Number of stations (03=3 stations) O P T I O N S 52A-31-COA-DM-DXXX-XXX click for memory spring (replace by 4).

77 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 52 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Accessories : Options : Compressed air, vacuum, inert gases Internal pilot : 1.4 to 8.5 bar External pilot : vacuum to 8.5 bar 1.4 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7.3 mm 1500 Nl/min (C v 1.5) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms 50Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms Pilot valve : DM-DXXX-XXX, including mounting screws and seal Blanking plate :M Seal (x3) : Mounting screw (x2) : NPTF threads. Isolation of inlet and/or exhaust. DIMENSIONS 6,5 DIA. 2 HOLES 32,0 25, ,0 19, , ,0 26, ,0 38,2 102,5 G1/8 OPTIONAL COMMON EXTERNAL PILOT. 14,5 51,5 69,5

78 O p t i o n s OPTIONS Codification table for voltages / Wire length / Manual operator / Electrical connection VALVE CODE D M - D XX X - X XX OPTIONS AVAILABLE FOR - pilot operated valves 400 & 52 Series

79 OPTIONS Back 1. VOLTAGE - D XX X - X XX VOLTAGE DA 24 V=/5,4 W DB 12 V=/5,4 W DC 12 V=/7,5 W DD 24 V=/7,3 W DE 12 V=/12,7 W DF 24 V=/12,7 W DK 110 V=/4,7 W DJ 28 V=/5,2 W DL 64 V=/6 W DM 36 V=/5,3 W DN 6 V=/6 W DR 90 V=/6,6 W DS 110 V=/7,3 W DT 75 V=/5,6 W DP 48 V=/5,8 W FA 12 V=/1,8 W FB 24 V=/1,8 W FE 12 V=/2,4 W FF 24 V=/2,4 W JA 120V~/60 Hz, 110V~/50 Hz (2,9 W) JB 240 V~/60 Hz, 220V~/50 Hz (2,9 W) JC 24 V~/60 Hz, 24V~/50 Hz (3,7 W) JD 100 V~/60 Hz, 100V~/50 Hz, 110V~/60 Hz (3,9 W) 2. WIRE LENGTH - D XX X - X XX WIRE LENGTH A 45 cm - 18 B 60 cm - 24 C 90 cm - 36 D 120 cm - 48 E 180 cm - 72 F 240 cm - 96 J For external plug-in connector

80 O p t i o n s OPTIONS Back 3. MANUAL OPERATOR - D XX X - X XX MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 4. ELECTRICAL CONNECTION - D XX X - X XX ELECTRICAL CONNECTION BA Flying leads BK BA with protection diode BL BA with protection varistor CA 1/2" NPS conduit JB Rectangular connector JD Rectangular connector with light JM Rectangular connector, male only KA Square connector KB Square connector with protection diode KC Square connector with protection varistor KD Square connector with light KE Square connector with light and protection diode KF Square connector with light and protection varistor KJ Square connector (male only) KK Square connector with protection diode (male only) KL Square connector with protection varistor (male only) TA Dual tabs TB TA with protection diode TD TA with light TE TA with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode

81 Direct solenoid and solenoid pilot operated valves Series 55 Individual mounting inline 3 EXH. 3 EXH. 2 CYL. 2 CYL. 1 1

82 Direct solenoid and solenoid pilot operated valves Series 55 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G1/4 - G3/ Nl/min inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset 55B-xx-xx-xxyzz Port size Pilot air NC valve NO valve CYL CYL G1/4 Internal EXH 55B-13-PI-XXYZZ EXH 55B-23-PI-XXYZZ G3/8 55B-14-PI-XXYZZ 55B-24-PI-XXYZZ G1/4 External 55B-13-PE-XXYZZ 55B-23-PE-XXYZZ G3/8 55B-14-PE-XXYZZ 55B-24-PE-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options

83 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 55 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : 1.8 to 10 bar External pilot : vacuum to 10 bar 1.8 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 8 mm G 1/4" : 1400 Nl/min (C v 1.4) - G 3/8" : 1600 Nl/min (C v 1.6) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA Holding : 10.9 VA = 1 to 17 W 24 V=/8.5 W Energize : 9 ms De-energize : 4.8 ms 50Hz/6 W Energize : 5-11 ms De-energize : 5-11 ms Spare parts : Options : Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PID-XXYZZ, including mounting screws and seal Check valve : NPTF threads. DIMENSIONS 25,0 56,0 EXHAUST PORT. G3/8 2 MTG. HOLES Ø 6,.6 mm 98,5 112,5 EXT PILOT LET & CYL PORTS ,0 43,7 26,0 44,5 56,0 23,5 29,5 46,0

84 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

85 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

86 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

87 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

88 Direct solenoid and solenoid pilot operated valves Series 56 Individual mounting inline ACCUMULATOR

89 Direct solenoid and solenoid pilot operated valves Series 56 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G3/8 - G1/2 - G3/ Nl/min inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset 56C-xx-xxyzz Port size Pilot air NC only valve NC pilot - NC spool NO only valve NO pilot - NC spool NC pilot - NO spool CYL CYL CYL G3/8 EXH 56C-15-XXYZZ EXH 56C-25-XXYZZ EXH 56C-65-XXYZZ G1/2 Internal 56C-16-XXYZZ 56C-26-XXYZZ 56C-66-XXYZZ G3/4 56C-18-XXYZZ 56C-28-XXYZZ 56C-68-XXYZZ G3/8 56C-35-XXYZZ 56C-45-XXYZZ 56C-75-XXYZZ G1/2 External 56C-36-XXYZZ 56C-46-XXYZZ 56C-76-XXYZZ G3/4 56C-38-XXYZZ 56C-48-XXYZZ 56C-78-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options

90 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 56 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : 1.7 to 10 bar External pilot : vacuum to 10 bar 1.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 16 mm G 3/8" : 4400 Nl/min (C v 4.4) - G 1/2" : 5000 Nl/min (C v 5.0) - G 3/4" : 5400 Nl/min (C v 5.4) 70 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA Holding : 10.9 VA = 1 to 17 W 24 V=/8.5 W Energize : 11 ms De-energize : 10,8ms 50Hz/6 W Energize : 7-12 ms De-energize : 9-14 ms Spare parts : Options : Solenoid operator (power 4 W) : D1-XXYZZ, including mounting screws and seal Pilot valve : 130B-XXYZZ, including function plate A Pilot mounting screws kit : N Check valve : NPTF threads. DIMENSIONS 56,0 18,0 MTG. HOLES Ø 8,6 G1/8 EXT. PILOT PORT 129,8 3 EXT PILOT 64, ,6 77,5 26,3 3,4 EXHAUST G3/4 28,6 57,2 38,0 76,0 35,5 39,0 73,5 PORT #1 (LET) & #2 (CYL.)

91 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

92 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

93 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

94 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

95 Direct solenoid and solenoid pilot operated valves Series 57 Individual mounting inline EXH. EXH. CYL. CYL.

96 Direct solenoid and solenoid pilot operated valves Series 57 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G1/2 - G3/4 - G Nl/min inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset 57C-xx-xxyzz Port size Pilot air NC only valve NC pilot - NC spool NO only valve NO pilot - NC spool NC pilot - NO spool CYL CYL CYL G1/2 EXH 57C-14-XXYZZ EXH 57C-24-XXYZZ EXH 57C-64-XXYZZ G3/4 Internal 57C-15-XXYZZ 57C-25-XXYZZ 57C-65-XXYZZ G1 57C-16-XXYZZ 57C-26-XXYZZ 57C-66-XXYZZ G1/2 57C-34-XXYZZ 57C-44-XXYZZ 57C-74-XXYZZ G3/4 External 57C-35-XXYZZ 57C-45-XXYZZ 57C-75-XXYZZ G1 57C-36-XXYZZ 57C-46-XXYZZ 57C-76-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JA Square connector V~/50Hz 2 Locking JC Square connector with light 22 24V~/50Hz 52 24V=/2,5W y Other Options BA zz Flying leads (45 cm) Other Options 78 24V=/24W 61 24V=/8,5W xx Other Options

97 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 57 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : 1.7 to 10 bar External pilot : vacuum to 10 bar 1.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 27 mm G 1/2" : 9000 Nl/min (C v 9.0) - G 3/4" : Nl/min (C v 12.7) - G 1" : Nl/min (C v 15.9) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 33 VA = 1 to 24 W Holding : 19.7 VA 24 V=/8.5 W Energize : 23 ms De-energize : 13ms 50Hz/16 W Energize : 9-16 ms De-energize : ms Solenoid operator (power 6 W) : D4-XXYZZ, including mounting screws and seal B Pilot valve : 250B-XXYZZ, including mounting screws and function plate A Check valve : NPTF threads. Explosion-proof model. DIMENSIONS MTG. HOLES Ø 8.6 ~28,0 42,0 G1/8 PILOT EXHAUST 55,7 45,7 26,2 G1/4 EXTERNAL PILOT PORT Scarico 10,2 LET & CYL PORTS 174,9 G1/8 PILOT EXH. CYL EXH 90,4 90,4 121,5 61,7 82,6 39,7 54,1 96,8 42,7 112,3

98 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

99 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

100 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

101 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

102 Direct solenoid and solenoid pilot operated valves Series 58 Individual mounting inline EXH. EXH. CYL. CYL.

103 Direct solenoid and solenoid pilot operated valves Series 58 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G1 - G1 1/4 - G1 1/ Nl/min inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset 58C-xx-xxyzz Port size Pilot air NC only valve NC pilot - NC spool NO only valve NO pilot - NC spool NC pilot - NO spool CYL CYL CYL G1 EXH 58C-14-XXYZZ EXH 58C-24-XXYZZ EXH 58C-64-XXYZZ G1 1/4 Internal 58C-15-XXYZZ 58C-25-XXYZZ 58C-65-XXYZZ G1 1/2 58C-16-XXYZZ 58C-26-XXYZZ 58C-66-XXYZZ G1 58C-34-XXYZZ 58C-44-XXYZZ 58C-74-XXYZZ G1 1/4 External 58C-35-XXYZZ 58C-45-XXYZZ 58C-75-XXYZZ G1 1/2 58C-36-XXYZZ 58C-46-XXYZZ 58C-76-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JA Square connector V~/50Hz 2 Locking JC Square connector with light 22 24V~/50Hz 52 24V=/2,5W y Other Options BA zz Flying leads (45 cm) Other Options 78 24V=/24W 61 24V=/8,5W xx Other Options

104 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 58 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : 1.7 to 10 bar External pilot : vacuum to 10 bar 1.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 38 mm G1" : Nl/min (C v 18.7) - G1 1/4" : Nl/min (C v 23.0) - G1 1/2" : Nl/min (C v 24.9) 125 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 33 VA Holding : 19.7 VA = 1 to 24 W 24 V=/8.5 W Energize : 25 ms De-energize : 18ms 50Hz/16 W Energize : ms De-energize : ms Spare parts : Options : Solenoid operator (power 6 W) : D4-XXYZZ, including mounting screws and seal B Pilot valve : 250B-XXYZZ, including mounting screws and function plate A Check valve : NPTF threads. Explosion-proof model. DIMENSIONS Ø MT G HOLES ~28,0 42,0 G1/8 PILOT EXHAUST 55,7 50,8 26,2 G1/4 EXTERNAL PILOT PORT Scarico 15,3 LET & CYL. PORTS 209,7 G1/8 PILOT EXH. CYL EXH 114,3 124,7 156,3 84,1 118,4 57,7 70,3 116,1 47,8 143,7

105 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

106 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

107 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

108 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

109 Direct solenoid and solenoid pilot operated valves Series 59 Individual mounting inline EXH. EXH. CYL. CYL.

110 Direct solenoid and solenoid pilot operated valves Series 59 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G2" - G2 1/ Nl/min inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset 59B-xx-xxyzz Port size Pilot air NC only valve NC pilot - NC spool NO only valve NO pilot - NC spool CYL CYL G2 Internal EXH 59B-15-XXYZZ EXH 59B-25-XXYZZ G2 1/2 59B-16-XXYZZ 59B-26-XXYZZ G2 External 59B-35-XXYZZ 59B-45-XXYZZ G2 1/2 59B-36-XXYZZ 59B-46-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JA Square connector V~/50Hz 2 Locking JC Square connector with light 22 24V~/50Hz 52 24V=/2,5W y Other Options BA zz Flying leads (45 cm) Other Options 78 24V=/24W 61 24V=/8,5W xx Other Options

111 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 59 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : 1.7 to 10 bar External pilot : vacuum to 10 bar 1.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 53 mm G2" : Nl/min (C v 55.0) - G2 1/2" : Nl/min (C v 60.0) 150 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 33 VA = 1 to 24 W Holding : 19.7 VA 24 V=/8.5 W Energize : 38 ms De-energize : 25ms 50Hz/16 W Energize : ms De-energize : ms Solenoid operator (power 6 W) : D4-XXYZZ, including mounting screws and seal B Pilot valve : 250B-XXYZZ, including mounting screws and function plate A Check valve : NPTF threads. Explosion-proof model. DIMENSIONS Ø MT G HOLES ~28,0 42,0 G1/8 PILOT EXHAUST 55,8 84,8 G1/4 EXTERNAL PILOT PORT EXHAUST PORT 271,6 LET & CYL. PORTS G1/8 PILOT EXH. CYL EXH 155,4 174,5 215,0 111,0 77,8 155,6 100,3 200,7 157,5 67,3

112 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

113 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

114 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

115 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

116 Direct solenoid and solenoid pilot operated valves Series 45 Individual mounting inline sub-base Manifold mounting stacking sub-base sub-base with pressure regulators sub-base with pressure and flow regulators Circuit bar mounting cylinder ports in base with pressure regulators plug-in plug-in with pressure regulators plug-in with flow regulators plug-in with pressure and flow regulators B A EXH.

117 Direct solenoid and solenoid pilot operated valves Series 45 Function Port size Flow (Max) Individual mounting 4/2 M5 - G1/8 150 Nl/min inline OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 45A-xxx-Dxxx-xxx Port size Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B G1/8 M5 EXH 45A-AC1-DXXX-XXX 45A-AD1-DXXX-XXX EXH 45A-GC1-DXXX-XXX 45A-GD1-DXXX-XXX WITH TEGRATED FLOW REGULATORS Port size Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B G1/8 M5 EXH 45A-AC2-DXXX-XXX 45A-AD2-DXXX-XXX EXH 45A-GC2-DXXX-XXX 45A-GD2-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50HZ A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50HZ J Connector 2 Locking KD Square connector with light AC 24V~/50HZ x Other Options x Other Options JB Rectangular connector FB 24V=/1,8W JD Rectangular connector with light DA 24V=/5,4W BA Flying leads DF 24V=/12,7W xx Other Options xx Other Options

118 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 45 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 100 Nl/min (C v 0.1) to 12.7 W : 150 Nl/min (C v 0.15) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 45A-000-DXXX-XXX, including mounting screws Seal (between solenoid and valve body) : Valve cover plate with flow controls : N NPTF threads. High flow up to 320 Nl/min, according to wattage. NAMUR interface. DIMENSIONS 62,0 F G 33,5 A B E H 27,5 24,5 22,5 EX A D B C 9,0 18,0 16,0 10,0 32,5 3,5 15,0 EX 30,0 23,5 B A 6,5 Port size A B C D E F G H 9,5 Ø 3,4 G1/8 7,5 16,0 10,0 9,5 7,5 11,5 14,5 9,5 13,8 M5 9,75 14,0 10,5 9,75 9,75 13,0 11,0 9,75 14,5

119 Direct solenoid and solenoid pilot operated valves Series 45 Function Port size Flow (Max) Individual mounting 4/2 M5 - G1/8 130 Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 45A-xxx-Dxxx-xxx Port size Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B Valve less base G 1/8 base M5 base EXH 45A-L00-DXXX-XXX 45A-LCA-DXXX-XXX 45A-LDA-DXXX-XXX EXH 45A-N00-DXXX-XXX 45A-NCA-DXXX-XXX 45A-NDA-DXXX-XXX WITH TEGRATED FLOW REGULATORS Port size Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B Valve less base G 1/8 base M5 base EXH 45A-L00-DXXX-XXX 45A-LCB-DXXX-XXX 45A-LDB-DXXX-XXX EXH 45A-N00-DXXX-XXX 45A-NCB-DXXX-XXX 45A-NDB-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50HZ A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50HZ J Connector 2 Locking KD Square connector with light AC 24V~/50HZ x Other Options x Other Options BA Flying leads FB 24V=/1,8W xx Other Options DA 24V=/5,4W DF 24V=/12,7W xx Other Options

120 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 45 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 110 Nl/min (C v 0.11) to 12.7 W : 130 Nl/min (C v 0.13) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 45A-000-DXXX-XXX, including mounting screws Seal (between solenoid and valve body) : Seal between base and valve : Flow control : N NPTF threads. High flow up to 200 Nl/min, according to wattage. DIMENSIONS A C L B G1/8 OPTIONAL BOTTOM CYLDER PORTS OPTIONAL PRESSURE SENSG PORT 21,5 4,0 EA EB 5,0 A B 7,0 ~ , ,0 24,0 9,0 6,5 B A 25,0 B 50,0 EB 50 EA A A 79,1 D EB EA 13,0 32,0 C C 15,1 16,0 Port size A B C D 64,0 32,0 G1/8 16,0 8,0 13,0 8,0 M5 12,0 6,0 15,0 10,0

121 Direct solenoid and solenoid pilot operated valves Series 45 Function Port size Flow (Max) Manifold mounting 4/2 M5 - G1/8 200 Nl/min stacking OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 45A-xxx-Dxxx-xxx Port size Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B G1/8 M5 EXH 45A-SC1-DXXX-XXX 45A-SD1-DXXX-XXX EXH 45A-TC1-DXXX-XXX 45A-TD1-DXXX-XXX WITH TEGRATED FLOW REGULATORS Port size Single operator Double operator A A B B A A B B G1/8 M5 EXH 45A-SC2-DXXX-XXX 45A-SD2-DXXX-XXX EXH 45A-TC2-DXXX-XXX 45A-TD2-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50HZ A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50HZ J Connector 2 Locking KD Square connector with light AC FB 24V~/50HZ 24V=/1,8W x Other Options x Other Options BA xx Flying leads Other Options DA 24V=/5,4W DF xx 24V=/12,7W Other Options End plate kit (Port size G1/4 ) : M P

122 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 45 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 140 Nl/min (C v 0.14) to 12.7 W : 200 Nl/min (C v 0.2) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 45A-000-DXXX-XXX, including mounting screws Seal (between solenoid and valve body) : Seal between valves : Tie-rod (x2) : Valve cover plate with flow controls : N NPTF threads. High flow up to 300 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS 32,5 7,0 ± 0,2 4 Ø 5,3 EX 62,5 15,5 EX 9,5 9,95 39,0 18,5 A B B A B A A 17,0 49,0 54,0 16,0 8,0 7,5 B 9,5 4,0 19,2 (± 0,1) G1/8 CYLDER PORTS 16,0 12,0 ± 0,2 M5 CYLDER PORTS EX EX 44,0 62,5

123 Direct solenoid and solenoid pilot operated valves Series 45 Function Port size Flow (Max) Manifold mounting 4/2 M5 - G1/8 110 Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 45A-xxx-Dxxx-xxx Port size Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B Valve less base G 1/8 base M5 base EXH 45A-L00-DXXX-XXX 45A-LCC-DXXX-XXX 45A-LDC-DXXX-XXX EXH 45A-N00-DXXX-XXX 45A-NCC-DXXX-XXX 45A-NDC-DXXX-XXX WITH TEGRATED FLOW REGULATORS Port size Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B Valve less base G 1/8 base M5 base EXH 45A-L00-DXXX-XXX 45A-LCD-DXXX-XXX 45A-LDD-DXXX-XXX EXH 45A-N00-DXXX-XXX 45A-NCD-DXXX-XXX 45A-NDD-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50HZ A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50HZ J Connector 2 Locking KD Square connector with light AC 24V~/50HZ x Other Options x Other Options BA Flying leads FB 24V=/1,8W xx Other Options DA 24V=/5,4W DF 24V=/12,7W xx Other Options End plate kit (Port size G1/4 ) : M P

124 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 45 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 90 Nl/min (C v 0.09) to 12.7 W : 110 Nl/min (C v 0.11) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 45A-000-DXXX-XXX, including mounting screws Seal (between solenoid and valve body) : Seal between base and valve : Seal between bases : Tie-rod (x2) : Side cover plate with flow controls : N NPTF threads. High flow up to 180 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS M5 PORTS CYLDER G1/8 CYLDER PORTS 10,0 20,5 17,5 B B 62,5 OPTIONAL G1/8 BOTTOM LET 51,0 A A 8,5 4,0 8,0 8,0 4,0 20,10 ±0,1 9,0 Ø 5,3 MTG. SLOT 33 OPTIONAL ISOLATOR G1/4 LET & EXHAUST PORTS BOTH ENDS 2,5 5,2 9,75 18,9 71,1 OPTIONAL GAGE PORT 29,0 13,5 13,7 17,3 19,0 EX

125 Direct solenoid and solenoid pilot operated valves Series 45 Function Port size Flow (Max) Manifold mounting 4/2 M5 - G1/8 110 Nl/min sub-base with pressure regulators OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 45A-xxx-Dxxx-xxx Port size Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B Valve less base G 1/8 base M5 base EXH 45A-L00-DXXX-XXX 45A-LCJ-DXXX-XXX 45A-LDJ-DXXX-XXX EXH 45A-N00-DXXX-XXX 45A-NCJ-DXXX-XXX 45A-NDJ-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50HZ A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50HZ J Connector 2 Locking KD Square connector with light AC 24V~/50HZ x Other Options x Other Options BA Flying leads FB 24V=/1,8W xx Other Options DA 24V=/5,4W DF xx 24V=/12,7W Other Options End plate kit (Port size G1/4 ) : M P. click for gauge port : Single operator : replace L by M. Double operator : replace N by P.

126 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 45 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 90 Nl/min (C v 0.09) to 12.7 W : 110 Nl/min (C v 0.11) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 45A-000-DXXX-XXX, including mounting screws Seal (between solenoid and valve body) : Seal between base and valve : Seal between bases : Tie-rod (x2) : Pressure regulator : 45A-00R. NPTF threads. High flow up to 180 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS M5 PORTS CYLDER G1/8 CYLDER PORTS 10,0 20,5 15,5 17,5 A B A B 62,5 OPTIONAL G1/8 BOTTOM LET 51,0 ADJ. LOCKG KNOB 8,5 4,0 8,0 8,0 4,0 LOCK 20,10 ±0,1 33,0 OPTIONAL ISOLATOR 9,0 ± 0,2 Ø 5,3 MTG. SLOT G1/4 LET & EXHAUST PORTS BOTH ENDS 2,5 29,0 13,5 EX Ø 15,5 9,75 13,7 17,3 19,0 14,0 13,5 5,2 18,9 OPTIONAL GAGE PORT 71,1 102,1 REGULATOR W/SLOTTED STEM 6,0 LOCKG STEM 13,4 LOCKG KNOB

127 Direct solenoid and solenoid pilot operated valves Series 45 Function Port size Flow (Max) Manifold mounting 4/2 M5 - G1/8 110 Nl/min sub-base with pressure and flow regulators OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 45A-xxx-Dxxx-xxx Port size Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B Valve less base G 1/8 base M5 base EXH 45A-L00-DXXX-XXX 45A-LCK-DXXX-XXX 45A-LDK-DXXX-XXX EXH 45A-N00-DXXX-XXX 45A-NCK-DXXX-XXX 45A-NDK-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage XX Wire length X Manual operator XX Electrical connection AB 220V~/50HZ A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50HZ J Connector 2 Locking KD Square connector with light AC 24V~/50HZ x Other Options x Other Options BA Flying leads FB 24V=/1,8W xx Other Options DA 24V=/5,4W DF 24V=/12,7W xx Other Options End plate kit (Port size G1/4 ) : M P. click for gauge port : Single operator : replace L by M Double operator : replace N by P.

128 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 45 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 90 Nl/min (C v 0.09) to 12.7 W : 110 Nl/min (C v 0.11) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 45A-000-DXXX-XXX, including mounting screws Seal (between solenoid and valve body) : Seal between base and valve : Seal between bases : Tie-rod (x2) : Pressure regulator : 45A-00R. Side cover plate with flow controls : N NPTF threads. High flow up to 180 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS M5 PORTS CYLDER 17,5 B B G1/8 CYLDER PORTS OPTIONAL G1/8 BOTTOM LET 62,5 10,0 20,5 51,0 A A 8,5 4,0 8,0 8,0 4,0 20,10 ±0,1 9,0 ± 0,2 OPTIONAL ISOLATOR Ø 5,3 MTG. SLOT G1/4 LET & EXHAUST PORTS BOTH ENDS 33,0 2,5 9,75 29,0 13,5 EX Ø 15,5 13,5 5,2 18,9 71,1 OPTIONAL GAGE PORT 13,7 17,3 19,0 102,1 REGULATOR W/ SLOTTED STEM 14,0 13,4 LOCKG KNOB

129 Direct solenoid and solenoid pilot operated valves Series 45 Function Port size Flow (Max) Circuit bar mounting 4/2 M5 - G1/8 100 Nl/min cylinder ports in base OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 45A-xxx-Dxxx-xxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B EXH 45A-L00-DXXX-XXX EXH 45A-N00-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50HZ A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50HZ J Connector 2 Locking KD Square connector with light AC 24V~/50HZ x Other Options x Other Options BA Flying leads FB 24V=/1,8W xx Other Options DA 24V=/5,4W DF 24V=/12,7W xx Other Options HOW TO ORDER CIRCUIT BAR ** EBM45A-xxxx-xx Port size Spacing mm Side cylinder ports Bottom cylinder ports M5 21 EBM45A-001D-XX EBM45A-002D-XX G1/8 21 EBM45A-001C-XX EBM45A-002C-XX HOW TO ORDER CIRCUIT BAR WITH FLOW REGULATORS ** Port size Spacing mm Side cylinder ports Bottom cylinder ports M5 26 EBM45A-015D-XX EBM45A-016D-XX G1/8 26 EBM45A-015C-XX EBM45A-016C-XX M5 40 EBM45A-025D-XX EBM45A-026D-XX G1/8 40 EBM45A-025C-XX EBM45A-026C-XX ** Other options available. Consult factory. XX = Number of stations (03=3 stations) Note : click for valves mounted on base at the factory (add - 9 to the model number).

130 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 45 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 80 Nl/min (C v 0.08) to 12.7 W : 100 Nl/min (C v 0.1) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 m Spare parts : Options : Solenoid operator (power 5.4 W) : 45A-000-DXXX-XXX, including mounting screws Seal between solenoid and valve body : Seal between base and valve : Valve mounting screw (x2) : Blanking plate : M NPTF threads. High flow up to 170 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS VALVE BLANKG PLATE 21,0 "A" 21,0 94,1 25,6 VALVE BLANKG PLATE 21,0 "A" 21,0 33,0 21,5 ~ ,5 B C L C L C L B B A A A 7,5 5,0 11,0 17,0 50,5 22,0 EXH 5,1 LOCKG RECESSED OPERATOR 35,5 B C L C L C L B B A A A 5,5 11,0 C B 65,6 OPTIONAL PRESSURE SENSG PORT (#10-32 UNF) 50,5 22,0 18,6 17,0 32,0 40,0 EXH 11,5 ~24.5 5,1 LOCKG RECESSED OPERATOR G1/8 2 PORTS BOTH ENDS SPACG SIZE Ø 5,2 MTG. HOLES A 21,0 8,0 7,0 5,0 23,6 B B B A A A OPTIONAL BOTTOM PORTS C L C L C L 5,5 5,5 3,18 13,6 PORT SIZE 7,14 B 25,4 FLOW CONTROL DIMENSIONS C STANDARD 21,0 G1/8 20,0 8,0 PER JB 26,0 M5 22,0 6,0

131 Direct solenoid and solenoid pilot operated valves Series 45 Function Port size Flow (Max) Circuit bar mounting 4/2 M5 - G1/8 100 Nl/min with pressure regulators OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 45A-xxx-Dxxx-xxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B Valve w/o gauge port Valve w/ gauge port EXH 45A-L00-DXXX-XXX 45A-M00-DXXX-XXX EXH 45A-N00-DXXX-XXX 45A-P00-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50HZ A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50HZ J Connector 2 Locking KD Square connector with light AC 24V~/50HZ x Other Options x Other Options BA Flying leads FB 24V=/1,8W xx Other Options DA 24V=/5,4W DF 24V=/12,7W xx Other Options HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY) ** EBM45A-xxxx-xx Port size Spacing mm Side cylinder ports Bottom cylinder ports M5 26 (w/o gauge) EBM45A-013D-XX EBM45A-014D-XX G1/8 26 (w/o gauge) EBM45A-013C-XX EBM45A-014C-XX M5 40 (w/ gauge) EBM45A-023D-XX EBM45A-024D-XX G1/8 40 (w/ gauge) EBM45A-023C-XX EBM45A-024C-XX ** Other options available. Consult factory. XX = Number of stations (03=3 stations) Pressure regulator : 35A-00M. Note : click for valves mounted on base at the factory (add - 9 to the model number).

132 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 45 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 80 Nl/min (C v 0.08) to 12.7 W : 100 Nl/min (C v 0.1) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 45A-000-DXXX-XXX, including mounting screws Seal between solenoid and valve body : Seal between base and valve : Valve mounting screw (x2) : Blanking plate valve : M Blanking plate regulator : M NPTF threads. High flow up to 170 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS VALVE BLANKG PLATE 64,5 21,0 "A" 21,0 17,5 33,0 5,1 LOCKG RECESSED OPERATOR C L C L C L 35,5 B B A A A 5,5 B C B 56,5 28,0 14,0 EXH 10,25 SPACG SIZE Standard Per JB Port size B A 21,0 26,0 C Ø 5,2. 2 MTG HOLES 11,0 11,0 5,0 5,5 8,0 35,5 22,0 5,0 A B A B A C L C L G1/8 2 PORTS BOTH ENDS 14,5 29,5 40,0 21,0 91,1 REGULATOR BLANKG PLATE 16,0 13,4 15,5 ADJ. LOCKG KNOB G1/8 20,0 8,0 B M5 22,0 6,0 C L

133 Direct solenoid and solenoid pilot operated valves Series 45 Function Port size Flow (Max) Circuit bar mounting 4/2 M5 - G1/8 100 Nl/min plug-in OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 45A-xxx-DxxJ-xFM HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG PLUG- Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B EXH 45A-L00-DXXJ-XFM EXH 45A-N00-DXXJ-XFM SOLENOID OPERATOR D XX J- X FM * XX Voltage X Manual operator AB AA AC FB DA DF xx 220V~/50Hz 110V~/50Hz 24V~/50Hz 24V=/1,8W 24V=/5,4W 24V=/12,7W Other Options 1 Non-locking 2 Locking x Other Options HOW TO ORDER PLUG- CIRCUIT BAR** ECD45A-xxxx-xx-xx Port size Spacing mm Side cylinder ports Bottom cylinder ports M5 21 ECD45A-001D-A0-XX ECD45A-002D-A0-XX G1/8 21 ECD45A-001C-A0-XX ECD45A-002C-A0-XX ** without light (A0) XX = Number of stations (03=3 stations) ** with light 220V~/50Hz (AB) ** with light 24V= (AD) Other options available. Consult factory. Note : for valves mounted on base at the factory (add - 9 to the model number). O P T I O N S ECD45A-002D-A0-XX click for double operator valve (replace by 8). (Bottom cylinder ports)

134 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 45 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 80 Nl/min (C v 0.08) to 12.7 W : 100 Nl/min (C v 0.1) 50 cm 3 /min Epoxy encapsulated - class A wires % ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 45A-000-DXXJ-XFM, including mounting screws Seal (between solenoid and valve body) : Seal between base and valve : Valve mounting screw (x2) : Blanking plate valve : E101. NPTF threads. High flow up to 170 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS 21,0 BLANKG STATION KIT 30,0 30,0 21,0 21,0 26,8 OPTIONAL PRESSURE SENSG PORT 73,8 5,1 LOCKG RECESSED OPERATOR C L C L C L C L 47,5 B A B A B A B A 28,5 68,5 19,8 EX 17,0 40,0 20,0 11,0 37,7 34,5 18,3 6,0 10,0 4,5 1,45 Ø 5,2 MOUNTG HOLES G1/8 LET & EXHAUST PORTS EACH END 13,5 29,0 57,3 78,0 84,8 1 NPSM CONDUIT EACH END 5,5 5,5 1,8 4,5 8,0 7,8 68,5 40,0 105,58 17,0 19,0 4,5 29,0 57,3 13,5 37,0

135 Direct solenoid and solenoid pilot operated valves Series 45 Function Port size Flow (Max) Circuit bar mounting 4/2 M5 - G1/8 100 Nl/min plug-in with pressure regulators OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 45A-xxx-DxxJ-xFM HOW TO ORDER VALVE FOR "PLUG-" CIRCUIT BAR Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B EXH 45A-L00-DXXJ-XFM EXH 45A-N00-DXXJ-XFM SOLENOID OPERATOR D XX J- X FM * XX Voltage X Manual operator AB AA AC FB DA DF xx 220V~/50Hz 110V~/50Hz 24V~/50Hz 24V=/1,8W 24V=/5,4W 24V=/12,7W Other Options 1 Non-locking 2 Locking x Other Options HOW TO ORDER CIRCUIT BAR WITH PRESSURE REGULATORS (TO BE ORDERED SEPARATELY) ** Port size M5 G1/8 M5 G1/8 M5 G1/8 ECD45A-xxxx-xx-xx Spacing mm Bottom cylinder ports ECD45A-004D-A0-XX ECD45A-004C-A0-XX ECD45A-014D-A0-XX ECD45A-014C-A0-XX ECD45A-024D-A0-XX ECD45A-024C-A0-XX ** without light (A0) XX = Number of stations (03=3 stations) ** with light 220V~/50Hz (AB) ** with light 24V= (AD) Other options available. Consult factory. Pressure regulator : 35A-00M Note : click for valves mounted on base at the factory (add - 9 to the model number).

136 B 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 45 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 80 Nl/min (C v 0.08) to 12.7 W : 100 Nl/min (C v 0.1) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 45A-000-DXXJ-XFM, including mounting screws Seal (between solenoid and valve body) : Seal between base and valve : Valve mounting screw (x2) : Blanking plate valve : E101. Blanking plate regulator : M NPTF threads. High flow up to 170 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS 21,0 BLANKG STATION KIT 30,0 30,0 21,0 21,0 26,8 OPTIONAL PRESSURE SENSG PORT 73,8 0,2 LOCKG RECESSED OPERATOR C L C L C L C L 47,5 B A B A B A 28,5 68,5 19,8 EX 17,0 40,0 20,0 11,0 6,0 10,0 4,5 Ø 5,2 MOUNTG HOLES 1,45 G1/8 LET & EXHAUST PORTS EACH END 13,5 29,0 57,3 78,0 84,8 1 NPSM CONDUIT EACH END 15,5 4,5 A 5,5 5,5 LOCK ADJ. LOCKG KNOB 60,5 20,7 34,5 37,0

137 Direct solenoid and solenoid pilot operated valves Series 45 Function Port size Flow (Max) Circuit bar mounting 4/2 M5 - G1/8 100 Nl/min plug-in with flow regulators OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 45A-xxx-DxxJ-xFM HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG PLUG- Single operator Double operator (Minimum DC wattage 5,4W) A A B B A A B B EXH 45A-L00-DXXX-XFM EXH 45A-N00-DXXX-XFM SOLENOID OPERATOR D XX J- X FM * XX Voltage X Manual operator AB AA 220V~/50Hz 110V~/50Hz 1 Non-locking 2 Locking AC 24V~/50Hz x Other Options FB 24V=/1,8W DA 24V=/5,4W DF 24V=/12,7W xx Other Options HOW TO ORDER "PLUG-" CIRCUIT BAR WITH FLOW REGULATORS ** ECD45A-xxxx-xx-xx Port size Spacing mm Side cylinder ports Bottom cylinder ports M ECD45A-016D-A0-XX G1/ ECD45A-016C-A0-XX M ECD45A-026D-A0-XX G1/ ECD45A-026C-A0-XX M5 30 ECD45A-035D-A0-XX G1/8 30 ECD45A-035C-A0-XX ** without light (A0) XX = Number of stations (03=3 stations) ** with light 220V~/50Hz (AB) ** with light 24V= (AD) Other options available. Consult factory. Note : click for valves mounted on base at the factory (add - 9 to the model number).

138 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 45 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 80 Nl/min (C v 0.08) to 12.7 W : 100 Nl/min (C v 0.1) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 45A-000-DXXJ-XFM, including mounting screws Seal (between solenoid and valve body) : Seal between base and valve : Valve mounting screw (x2) : Blanking plate valve : E101. Flow control : N NPTF threads. High flow up to 170 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS 21,0 BLANKG STATION KIT 30,0 30,0 21,0 21,0 26,8 OPTIONAL PRESSURE SENSG PORT 73,8 5,1 LOCKG RECESSED OPERATOR C L C L C L C L 47,5 B A B A B A B A 28,5 68,5 19,8 EX 17,0 40,0 20,0 11,0 6,0 10,0 4,5 Ø 5,2 MOUNTG HOLES 1,45 G1/8 LET & EXHAUST PORTS EACH END 13,5 29,0 57,3 78,0 84,8 1 NPSM CONDUIT EACH END MAX. EXTENSION 13,2 4,5 37,0

139 Direct solenoid and solenoid pilot operated valves Series 45 Function Port size Flow (Max) Circuit bar mounting 4/2 M5 - G1/8 100 Nl/min plug-in with pressure and flow regulators OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. The patented solenoid develops high shifting forces. 4. Powerful return spring. 5. Manual operator standard on all valves. 6. Burn-out proof solenoid on AC service. HOW TO ORDER Reset 45A-xxx-DxxJ-xFM HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG PLUG- Single operator A B A B Double operator (Minimum DC wattage 5,4W) A A B B EXH 45A-L00-DXXX-XFM EXH 45A-N00-DXXX-XFM SOLENOID OPERATOR D XX J- X FM * XX Voltage X Manual operator AB 220V~/50Hz AA 110V~/50Hz AC 24V~/50Hz FB 24V=/1,8W DA 24V=/5,4W DF 24V=/12,7W xx Other Options HOW TO ORDER "PLUG-" CIRCUIT BAR WITH PRESSURE AND FLOW REGULATORS (TO BE ORDERED SEPARATELY)** Port size Spacing mm 1 Non-locking 2 Locking ECD45A-xxxx-xx-02 x Other Options Bottom cylinder ports M5 G1/8 M5 G1/8 M5 G1/8 ** without light (A0) XX = Number of stations (03=3 stations) ** with light 220V~/50Hz (AB) ** with light 24V= (AD) Other options available. Consult factory. Pressure and flow regulator : 45A-002 Note : click for valves mounted on base at the factory (add - 9 to the model number) ECD45A-007D-A0-XX ECD45A-007C-A0-XX ECD45A-017D-A0-XX ECD45A-017C-A0-XX ECD45A-027D-A0-XX ECD45A-027C-A0-XX 2

140 B 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 45 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 1.8 W : 80 Nl/min (C v 0.08) to 12.7 W : 100 Nl/min (C v 0.1) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 6 ms De-energize : 2 ms 50Hz/6 W Energize : 3-8 ms De-energize : 2-7 ms Spare parts : Options : Solenoid operator (power 5.4 W) : 45A-000-DXXJ-XFM, including mounting screws Seal between solenoid and valve body : Seal between base and valve : Valve mounting screw (x2) : Blanking plate valve : E101. Blanking plate regulator : M NPTF threads. High flow up to 170 Nl/min, according to wattage. Isolation of inlet and/or exhaust. DIMENSIONS 21,0 BLANKG STATION KIT 30,0 30,0 21,0 21,0 26,8 OPTIONAL PRESSURE SENSG PORT 73,8 5,1 LOCKG RECESSED OPERATOR C L C L C L C L 47,5 B A B A B A 28,5 68,5 19,8 EX 17,0 40,0 20,0 11,0 6,0 10,0 4,5 Ø 5,2 MOUNTG HOLES 1,45 G1/8 LET & EXHAUST PORTS EACH END 13,5 29,0 57,3 78,0 84,8 1 NPSM CONDUIT EACH END MAX. EXTENSION 13,2 15,5 A 5,5 5,5 LOCK ADJ. LOCKG KNOB 4,5 60,5 20,7 34,5 37,0

141 O p t i o n s OPTIONS Codification table for voltages / Wire length / Manual operators / Electrical connections VALVE CODE - D XX X - X XX OPTIONS AVAILABLE FOR - Solenoid valves 35 & 45 Series - Pilot operated valves with pilots type 35 Series Series : 82

142 OPTIONS Back 1. VOLTAGE - D XX X - X XX VOLTAGE AA 120 V~/60 Hz V/50 Hz AB 240 V~/60 Hz V/50 Hz AC 24 V~/60 Hz - 24 V/50 Hz AD 24 V~/60 Hz AE 200 V~/60 Hz AF 240 V~/50 Hz AG 240 V~/50 Hz DA 24 V=/5,4 W DB 12 V=/5,4 W DC 12 V=/7,5 W DD 24 V=/7,3 W DE 12 V=/12,7 W CLSF DF 24 V=/12,7 W CLSF DK 110 V=/4,7 W DL 64 V=/6 W DM 36 V=/5,3 W DN 6 V=/6 W DP 48 V=/5,8 W DU 24 V=/6 W EA 12 V=/6 W FA 12 V=/1,8 W FB 24 V=/1,8 W FE 12 V=/2,4 W FF 24 V=/2,4 W 2. WIRE LENGTH - D XX X - X XX WIRE LENGTH A 45 cm - 18 B 60 cm - 24 C 90 cm - 36 D 120 cm - 48 E 180 cm - 72 F 240 cm - 96 J For external plug-in connector P For plug-in valves (82 Series only)

143 O p t i o n s OPTIONS Back 3. MANUAL OPERATOR - D XX X - X XX MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 4. ELECTRICAL CONNECTION - D XX X - X XX ELECTRICAL CONNECTION BA Flying leads BK BA with protection diode BL BA with protection varistor CA 1/2" NPS conduit JB Rectangular connector JD Rectangular connector with light JM Rectangular connector, male only KA Square connector KB Square connector with protection diode KC Square connector with protection varistor KD Square connector with light KE Square connector with light and protection diode KF Square connector with light and protection varistor KJ Square connector (male only) KK Square connector with protection diode (male only) KL Square connector with protection varistor (male only) MA Electrical common conduit TA Dual tabs TB TA with protection diode TD TA with light TE TA with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode DA* Plug-in connector DK* DA with protection diode DL* DA with protection varistor * To be used with 82 Series only

144 Direct solenoid and solenoid pilot operated valves Series 700 Individual mounting inline Manifold mounting stacking EXH. B A

145 Direct solenoid and solenoid pilot operated valves Series 700 Function Port size Flow (Max) Individual mounting 4/2 G1/8 - G1/4 700 Nl/min inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset xxxx-xx-xx-xxyzz Port size Pilot air Single operator Double operator A A B B A A B B G1/8 Internal EXH 711C-13-PI-XXYZZ EXH 721C-13-PI-XXYZZ G1/4 711C-14-PI-XXYZZ 721C-14-PI-XXYZZ G1/8 External 711C-13-PE-XXYZZ 721C-13-PE-XXYZZ G1/4 711C-14-PE-XXYZZ 721C-14-PE-XXYZZ HOW TO ORDER VALVE WITH FLOW REGULATORS Port size Pilot air Single operator Double operator A A B B A A B B G1/8 Internal EXH 712C-13-PI-XXYZZ EXH 722C-13-PI-XXYZZ G1/4 712C-14-PI-XXYZZ 722C-14-PI-XXYZZ G1/8 External 712C-13-PE-XXYZZ 722C-13-PE-XXYZZ G1/4 712C-14-PE-XXYZZ 722C-14-PE-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options

146 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 700 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator : 1.4 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator : 1.4 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 5.6 mm G1/8" : 600 Nl/min (C v 0.6) - G1/4" : 700 Nl/min (C v 0.7) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize : 6.4 ms De-energize : 8.5ms 50Hz/6 W Energize : 4-10 ms De-energize : 7-13 ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PID-XXYZZ, including mounting screws and seal Valve cover plate with integral flow controls : N NPTF threads. DIMENSIONS 171,5 116,3 85,8 EX 41,5 59,0 16,7 12,7 EX A 44,8 14,7 2 MTG. HOLES Ø 6,5 19,0 10,5 56,0 EX Port size A 41,0 30,0 7,3 16,8 7,3 9,5 A B G1/8 G1/4 21,0 24,0 19,0 8,5

147 Direct solenoid and solenoid pilot operated valves Series 700 Function Port size Flow (Max) Manifold mounting 4/2 G1/8 - G1/4 800 Nl/min stacking OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset xxxx-xx-xx-xxyzz Port size Pilot air Single operator Double operator A A B B A A B B G1/8 Internal EXH 713C-13-PI-XXYZZ EXH 723C-13-PI-XXYZZ G1/4 713C-14-PI-XXYZZ 723C-14-PI-XXYZZ HOW TO ORDER VALVE WITH FLOW REGULATORS Port size Pilot air Single operator Double operator A A B B A A B B G1/8 Internal EXH 714C-13-PI-XXYZZ EXH 724C-13-PI-XXYZZ G1/4 714C-14-PI-XXYZZ 724C-14-PI-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options End plate kit (Port size G1/4") : M P (internal pilot). M P (external pilot).

148 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 700 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator : 1.4 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator : 1.4 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 5.6 mm G1/8" : 700 Nl/min (C v 0.7) - G1/4" : 800 Nl/min (C v 0.8) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize : 6.4 ms De-energize : 8.5ms 50Hz/6 W Energize : 4-10 ms De-energize : 7-13 ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PID-XXYZZ, including mounting screws and seal Valve cover plate with integral flow controls : N NPTF threads. Isolation of inlet and/or exhaust. DIMENSIONS 171,5 116,3 85,8 43,0 B 3,3 R 56,0 27,0 22,0 ± 0,2 76,3 58,9 42,5 19,5 8,0 EX 44,8 30,0 ± 0,2 17,5 12,5 B B A A EX EX 15,0 G1/4 LET G3/8 EXHAUST Port size B G1/8 G1/4 21,0 24,0

149 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

150 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

151 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

152 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

153 Direct solenoid and solenoid pilot operated valves Series 900 Individual mounting inline Manifold mounting stacking

154 Direct solenoid and solenoid pilot operated valves Series 900 Function Port size Flow (Max) Individual mounting 4/2 G1/8 - G1/ Nl/min inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset xxxx-pm-xxyzz Port size Single operator Double operator A A B B A A B B G1/8 G1/4 EXH 915B-PM-XXYZZ 916B-PM-XXYZZ EXH 925B-PM-XXYZZ 926B-PM-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options

155 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 900 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Single operator : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G1/8" : 800 Nl/min (C v 0.8) - G1/4" : 1200 Nl/min (C v 1.2) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA Holding : 10.9 VA = 1 to 17.1 W 24 V=/8.5 W Energize :8 ms De-energize : 10ms 50Hz/6 W Energize : 5-10 ms De-energize : 8-15 ms Spare parts : Options : Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Mounting screw pilot to main valve : NPTF threads. DIMENSIONS 56,0 OPTIONAL G1/8 PILOT EXH. 25,0 Ø 5,2 MTG. HOLES 8,5 72,7 CYL B CYL A 21,0 EXH 15,0 OPER. A EXH OPER. B 35,0 45,0 26,0 7,5 EXH 36,8 75,8 SGLE SOLENOID 116,6 DOUBLE SOLENOID

156 Direct solenoid and solenoid pilot operated valves Series 900 Function Port size Flow (Max) Manifold mounting 4/2 G1/8 - G1/4 - G3/ Nl/min stacking OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset xxxx-pm-xxyzz Port size Single operator Double operator A A B B A A B B G1/8 G1/4 G3/8 EXH 917B-PM-XXYZZ 918B-PM-XXYZZ 919B-PM-XXYZZ Mod 005 EXH 927B-PM-XXYZZ 928B-PM-XXYZZ 929B-PM-XXYZZ Mod 005 SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options BA Flying leads (45 cm) 59 24V=/2,5W zz Other Options 87 24V=/17,1W 61 24V=/8,5W xx Other Options End plate kit (Port size : G3/8") : M P.

157 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 900 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Single operator : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G1/8" : 1200 Nl/min (C v 1.2) - G1/4" : 1400 Nl/min (C v 1.4) - G3/8" : 1400 Nl/min (C v 1.4) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA Holding : 10.9 VA = 1 to 17.1 W 24 V=/8.5 W Energize : 8 ms De-energize : 10ms 50Hz/6 W Energize : 5-10 ms De-energize : 8-15 ms Spare parts : Options : Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Mouting screw pilot to main valve : Pressure seal between valves : Tie-rod (x2) : NPTF threads. DIMENSIONS 7,5 SGLE SOLENOID 80,0 45,0 15,0 56,0 34,0 29,0 EXH 11,1 ± 0,2 17,0 OPER. A OPER. A CYL B CYL B CYL A CYL A OPER. B OPER. B 12,9 25,4 ± 0,1 15,5 40,0 34,0 EXH 25,0 87,7 EXH Ø 6,4 MTG. 30,0 28,0 HOLES DOUBLE SOLENOID 116,6 13,8 10,0 ± 0,4 G3/8 LET & EXH. BOTH ENDS 37,0 11,5 7,5

158 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

159 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

160 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

161 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

162 Direct solenoid and solenoid pilot operated valves Series 82 Individual mounting sub-base sub-base plug-in Manifold mounting sub-base sub-base plug-in EXH B A EXH EXH

163 Direct solenoid and solenoid pilot operated valves Series 82 Function Port size Flow (Max) Individual mounting 4/2-4/3 G1/8 - G1/4 - G3/ Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset 82A-xx-xxx-TM-Dxxx-xxx Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A Valve less base EXH 82A-AB-000-TM-DXXX-XXX EXH 82A-BB-000-TM-DXXX-XXX EXH 82A-EB-000-TM-DXXX-XXX EXH 82A-FB-000-TM-DXXX-XXX EXH 82A-GB-000-TM-DXXX-XXX sub-base Internal 82A-AB-DAA-TM-DXXX-XXX 82A-BB-DAA-TM-DXXX-XXX 82A-EB-DAA-TM-DXXX-XXX 82A-FB-DAA-TM-DXXX-XXX 82A-GB-DAA-TM-DXXX-XXX G1/8 External 82A-AB-DAD-TM-DXXX-XXX 82A-BB-DAD-TM-DXXX-XXX 82A-EB-DAD-TM-DXXX-XXX 82A-FB-DAD-TM-DXXX-XXX 82A-GB-DAD-TM-DXXX-XXX sub-base Internal 82A-AB-EAA-TM-DXXX-XXX 82A-BB-EAA-TM-DXXX-XXX 82A-EB-EAA-TM-DXXX-XXX 82A-FB-EAA-TM-DXXX-XXX 82A-GB-EAA-TM-DXXX-XXX G1/4 External 82A-AB-EAD-TM-DXXX-XXX 82A-BB-EAD-TM-DXXX-XXX 82A-EB-EAD-TM-DXXX-XXX 82A-FB-EAD-TM-DXXX-XXX 82A-GB-EAD-TM-DXXX-XXX sub-base Internal 82A-AB-FAA-TM-DXXX-XXX 82A-BB-FAA-TM-DXXX-XXX 82A-EB-FAA-TM-DXXX-XXX 82A-FB-FAA-TM-DXXX-XXX 82A-GB-FAA-TM-DXXX-XXX G3/8 External 82A-AB-FAD-TM-DXXX-XXX 82A-BB-FAD-TM-DXXX-XXX 82A-EB-FAD-TM-DXXX-XXX 82A-FB-FAD-TM-DXXX-XXX 82A-GB-FAD-TM-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50Hz A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50Hz J Connector 2 Locking KD Square connector with light AC 24V~/50Hz x Other Options x Other Options JB Rectangular connector FB 24V=/1,8W JD Rectangular connector with light DA DF 24V=/5,4W 24V=/12,7W BA xx Flying leads Other Options xx Other Options O P T I O N S 82A-AB-000-TMDXXX-XXX click for dual pressure valves (replace A by C, B by D, E by M, F by L, G by H).

164 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 82 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G1/4" : 1300 Nl/min (C v 1.3) - G3/8" : 1350 Nl/min (C v 1.35) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA = 1.8 to 12.7 W Holding : 7.7 VA 24 V=/5.4 W Energize : 9 ms De-energize : 6ms 50Hz/6 W Energize : 5-12 ms De-energize :6-13 ms Solenoid operator (power 5.4 W) : 35A-000-DXXX-XXX, including mounting screws Seal between solenoid and pilot body : Pilot valve : TM-DXXX-XXX, including seal Mounting screw pilot to main valve : Pressure seal between valve and base : Mounting screw valve to base (x2) : NPTF threads. Flow controls. Explosion-proof model. DIMENSIONS 149,0 DOUBLE OPERATOR 120,5 SGLE OPERATOR 32,0 149,0 DOUBLE OPERATOR 120,5 SGLE OPERATOR A EXH 24,0 4,5 27,5 32,0 EXH 27,5 32,0 2 Ø 5,3 15,5 12,5 15,5 14,5 B A EXH 20,5 41,0 21,0 26,0 21,0 80,0 26,0 47,3 9,0 G 1/8" 1/2" NPSM PILOT 22,0 83,2 104,2 A CONDUIT CYL A CYL B 14,5 11,3 50,0 25,0 38,5 PILOT

165 Direct solenoid and solenoid pilot operated valves Series 82 Function Port size Flow (Max) Individual mounting 4/2-4/3 G1/8 - G1/4 - G3/ Nl/min sub-base plug-in OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset 82A-xx-xxx-TM-DxxP-yDA Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A EXH EXH EXH EXH EXH Valve less base 82A-AA-000-TM-DXXP-YDA 82A-BA-000-TM-DXXP-YDA 82A-EA-000-TM-DXXP-YDA 82A-FA-000-TM-DXXP-YDA 82A-GA-000-TM-DXXP-YDA sub-base Internal 82A-AA-DAA-TM-DXXP-YDA 82A-BA-DAA-TM-DXXP-YDA 82A-EA-DAA-TM-DXXP-YDA 82A-FA-DAA-TM-DXXP-YDA 82A-GA-DAA-TM-DXXP-YDA G1/8 External 82A-AA-DAD-TM-DXXP-YDA 82A-BA-DAD-TM-DXXP-YDA 82A-EA-DAD-TM-DXXP-YDA 82A-FA-DAD-TM-DXXP-YDA 82A-GA-DAD-TM-DXXP-YDA sub-base Internal 82A-AA-EAA-TM-DXXP-YDA 82A-BA-EAA-TM-DXXP-YDA 82A-EA-EAA-TM-DXXP-YDA 82A-FA-EAA-TM-DXXP-YDA 82A-GA-EAA-TM-DXXP-YDA G1/4 External 82A-AA-EAD-TM-DXXP-YDA 82A-BA-EAD-TM-DXXP-YDA 82A-EA-EAD-TM-DXXP-YDA 82A-FA-EAD-TM--DXXP-YDA 82A-GA-EAD-TM-DXXP-YDA sub-base Internal 82A-AB-FAA-TM-DXXP-YDA 82A-BA-FAA-TM-DXXP-YDA 82A-EA-FAA-TM-DXXP-YDA 82A-FA-FAA-TM-DXXP-YDA 82A-GA-FAA-TM-DXXP-YDA G3/8 External 82A-AA-FAD-TM-DXXP-YDA 82A-BA-FAD-TM-DXXP-YDA 82A-EA-FAD-TM-DXXP-YDA 82A-FA-FAD-TM-DXXP-YDA 82A-GA-FAD-TM-DXXP-YDA SOLENOID OPERATOR D XX P- Y DA * XX Voltage Y Manual operator AB AA 220V~/50Hz 110V~/50Hz 1 Non-locking 2 Locking AC 24V~/50Hz y Other Options FB 24V=/1,8W DA 24V=/5,4W DF 24V=/12,7W xx Other Options O P T I O N S 82A-AA-000-TM-DXXX-YDA click for dual pressure valves (replace A by C, B by D, E by M, F by L, G by H).

166 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 82 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G1/8" : 900 Nl/min (C v 0.9) - G1/4" : 1300 Nl/min (C v 1.3) - G3/8" : 1350 Nl/min (C v 1.35) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA = 1.8 to 12.7 W Holding : 7.7 VA 24 V=/5.4 W Energize : 9 ms De-energize : 6ms 50Hz/6 W Energize : 5-12 ms De-energize :6-13 ms Solenoid operator (power 5.4 W ) : 35A-000-DXXP-YDA, including mounting screws Seal between solenoid and pilot body : Pilot valve : TM-DXXP-YDA, including seal Mounting screw pilot to main valve : Pressure seal between valve and base : Mounting screw valve to base (x2) : NPTF threads. Flow controls. Explosion-proof model. Lights in base or valve body. DIMENSIONS 149,0 DOUBLE OPERATOR 120,5 SGLE OPERATOR 3,9 (OPTION : light) 3,9 (OPTION) 83,2 A EXH 24,0 PILOT 22,0 4,5 27,5 32,0 11,3 50,0 25,0 104,2 27,5 32,0 2 Ø 5,3 21,0 26,0 47,3 1/2 NPSM 38,5 PILOT 15,5 12,5 15,5 14,5 B A EXH 20,5 41,0 A CONDUIT CYL A CYL B 14,5 Port size A G1/8, G1/4 (OPTION) 21,0 26,0 80,0 9,0 G1/8 - G1/4 G3/8 19,5 17,0

167 Direct solenoid and solenoid pilot operated valves Series 82 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G1/4 - G3/ Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset 82A-xx-xxx-TM-Dxxx-xxx Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A Valve less base EXH 82A-AB-000-TM-DXXX-XXX EXH 82A-BB-000-TM-DXXX-XXX EXH 82A-EB-000-TM-DXXX-XXX EXH 82A-FB-000-TM-DXXX-XXX EXH 82A-GB-000-TM-DXXX-XXX sub-base Internal 82A-AB-EKA-TM-DXXX-XXX 82A-BB-EKA-TM-DXXX-XXX 82A-EB-EKA-TM-DXXX-XXX 82A-FB-EKA-TM-DXXX-XXX 82A-GB-EKA-TM-DXXX-XXX G1/4 External 82A-AB-EKD-TM-DXXX-XXX 82A-BB-EKD-TM-DXXX-XXX 82A-EB-EKD-TM-DXXX-XXX 82A-FB-EKD-TM-DXXX-XXX 82A-GB-EKD-TM-DXXX-XXX sub-base Internal 82A-AB-FKA-TM-DXXX-XXX 82A-BB-FKA-TM-DXXX-XXX 82A-EB-FKA-TM-DXXX-XXX 82A-FB-FKA-TM-DXXX-XXX 82A-GB-FKA-TM-DXXX-XXX G3/8 External 82A-AB-FKD-TM-DXXX-XXX 82A-BB-FKD-TM-DXXX-XXX 82A-EB-FKD-TM-DXXX-XXX 82A-FB-FKD-TM-DXXX-XXX 82A-GB-FKD-TM-DXXX-XXX SOLENOID OPERATOR D XX X - X XX * XX Voltage X Wire length X Manual operator XX Electrical connection AB 220V~/50Hz A 45 cm (Flying leads) 1 Non-locking KA Square connector AA 110V~/50Hz J Connector 2 Locking KD Square connector with light AC 24V~/50Hz x Other Options x Other Options JB Rectangular connector FB 24V=/1,8W JD Rectangular connector with light DA DF 24V=/5,4W 24V=/12,7W BA xx Flying leads Other Options xx Other Options O P T I O N S 82A-AB-000-TM-DXXX-XXX click for dual pressure valves (replace A by C, B by D, E by M, F by L, G by H).

168 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 82 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G1/4" : 1300 Nl/min (C v 1.3) - G3/8" : 1350 Nl/min (C v 1.35) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA = 1.8 to 12.7 W Holding : 7.7 VA 24 V=/5.4 W Energize : 9 ms De-energize : 6ms 50Hz/6 W Energize : 5-12 ms De-energize : 6-13 ms Solenoid operator (power 5.4 W) : 35A-000-DXXX-XXX, including mounting screws Seal between solenoid and pilot body : Pilot valve : TM-DXXX-XXX, including seal Mounting screw pilot to main valve : Pressure seal between valve and base : Mounting screw valve to base (x2) : Tie-rod (x2) : NPTF threads. Flow controls. Explosion-proof model. DIMENSIONS ,7 DOUBLE OPERATOR 164,2 SGLE OPERATOR 3,9 (OPTION : light) 174,7 DOUBLE OPERATOR 164,2 SGLE OPERATOR 1 1/4 NPSM 9,0 EXH COND 126,2 46,0 28,0 27,0 EXH COND G1/8 (OPTION) 17,5 32,0 59,0 26,5 47,0 164,2 G3/8 6,5 96,0 4,5 23,0 12,0 CYL A CYL B 22,5 46,0 ± 0,2 37,0 23,0 18,5 32,0 59,0 2 Ø 5,3 18,5 G1/8 105,2 EXT PILOT CYL B 36,0 126,2 60,5 EXH 16,0 CYL A 14,0 COND 16 18,5 46,0

169 Direct solenoid and solenoid pilot operated valves Series 82 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G1/4 - G3/ Nl/min sub-base plug-in OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset 82A-xx-xxx-TM-DxxP-xDA Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 centro chiuso 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A EXH EXH EXH EXH EXH Valve less base 82A-AA-000-TM-DXXP-XDA 82A-BA-000-TM-DXXP-XDA 82A-EA-000-TM-DXXP-XDA 82A-FA-000-TM-DXXP-XDA 82A-GA-000-TM-DXXP-XDA sub-base Internal 82A-AA-EKA-TM-DXXP-XDA 82A-BA-EKA-TM-DXXP-XDA 82A-EA-EKA-TM-DXXP-XDA 82A-FA-EKA-TM-DXXP-XDA 82A-GA-EKA-TM-DXXP-XDA G1/4 External 82A-AA-EKD-TM-DXXP-XDA 82A-BA-EKD-TM-DXXP-XDA 82A-EA-EKD-TM-DXXP-XDA 82A-FA-EKD-TM-DXXP-XDA 82A-GA-EKD-TM-DXXP-XDA sub-base Internal 82A-AA-FKA-TM-DXXP-XDA 82A-BA-FKA-TM-DXXP-XDA 82A-EA-FKA-TM-DXXP-XDA 82A-FA-FKA-TM-DXXP-XDA 82A-GA-FKA-TM-DXXP-XDA G3/8 External 82A-AA-FKD-TM-DXXP-XDA 82A-BA-FKD-TM-DXXP-XDA 82A-EA-FKD-TM-DXXP-XDA 82A-FAFKD-TM-DXXP-XDA 82A-GA-FKD-TM-DXXP-XDA SOLENOID OPERATOR D XX P- X DA * XX Voltage X Manual operator AB AA AC FB DA DF xx 220V~/50Hz 110V~/50Hz 24V~/50Hz 24V=/1,8W 24V=/5,4W 24V=/12,7W Other Options 1 Non-locking 2 Locking y Other Options O P T I O N S 82A-AA-000-TM-DXXP-XDA click for dual pressure valves (replace A by C, B by D, E by M, F by L, G by H). Fastening kit : N P

170 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 82 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G1/4" : 1300 Nl/min (C v 1.3) - G3/8" : 1350 Nl/min (C v 1.35) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA = 1.8 to 12.7 W Holding : 7.7 VA 24 V=/5.4 W Energize : 9 ms De-energize : 6ms 50Hz/6 W Energize : 5-12 ms De-energize :6-13 ms Solenoid operator (power 5.4 W) : 35A-000-DXXP-YDA, including mounting screws Seal between solenoid and pilot body : Pilot valve : TM-DXXP-YDA, including seal Mounting screw pilot to main valve : Pressure seal between valve and base : Mounting screw valve to base (x2) : Tie-rod (x2) : NPTF threads. Flow controls. Explosion-proof model. Lights in base or valve body. DIMENSIONS 174,7 DOUBLE OPERATOR 164,2 SGLE OPERATOR 174,7 DOUBLE OPERATOR 164,2 SGLE OPERATOR 1 1/4 NPSM 9,0 EXH COND 126,2 46,0 28,0 27,0 EXH COND G1/8 (OPTION) 17,5 32,0 59,0 26,5 47,0 164,2 3/8 4 PLACES AND EXHAUST 6,5 96,0 4,5 23,0 12,0 CYL A CYL B 22,5 46,0 ± 0,2 37,0 23,0 18,5 32,0 59,0 2 Ø 5,3 18,5 G1/8 105,2 EXT PILOT CYL B 36,0 126,2 60,5 EXH 16,0 CYL A COND 16 14,0 18,5 46,0

171 O p t i o n s OPTIONS Codification table for voltages / Wire length / Manual operators / Electrical connections VALVE CODE - D XX X - X XX OPTIONS AVAILABLE FOR - Solenoid valves 35 & 45 Series - Pilot operated valves with pilots type 35 Series Series : 82

172 OPTIONS Back 1. VOLTAGE - D XX X - X XX VOLTAGE AA 120 V~/60 Hz V/50 Hz AB 240 V~/60 Hz V/50 Hz AC 24 V~/60 Hz - 24 V/50 Hz AD 24 V~/60 Hz AE 200 V~/60 Hz AF 240 V~/50 Hz AG 240 V~/50 Hz DA 24 V=/5,4 W DB 12 V=/5,4 W DC 12 V=/7,5 W DD 24 V=/7,3 W DE 12 V=/12,7 W CLSF DF 24 V=/12,7 W CLSF DK 110 V=/4,7 W DL 64 V=/6 W DM 36 V=/5,3 W DN 6 V=/6 W DP 48 V=/5,8 W DU 24 V=/6 W EA 12 V=/6 W FA 12 V=/1,8 W FB 24 V=/1,8 W FE 12 V=/2,4 W FF 24 V=/2,4 W 2. WIRE LENGTH - D XX X - X XX WIRE LENGTH A 45 cm - 18 B 60 cm - 24 C 90 cm - 36 D 120 cm - 48 E 180 cm - 72 F 240 cm - 96 J For external plug-in connector P For plug-in valves (82 Series only)

173 O p t i o n s OPTIONS Back 3. MANUAL OPERATOR - D XX X - X XX MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 4. ELECTRICAL CONNECTION - D XX X - X XX ELECTRICAL CONNECTION BA Flying leads BK BA with protection diode BL BA with protection varistor CA 1/2" NPS conduit JB Rectangular connector JD Rectangular connector with light JM Rectangular connector, male only KA Square connector KB Square connector with protection diode KC Square connector with protection varistor KD Square connector with light KE Square connector with light and protection diode KF Square connector with light and protection varistor KJ Square connector (male only) KK Square connector with protection diode (male only) KL Square connector with protection varistor (male only) MA Electrical common conduit TA Dual tabs TB TA with protection diode TD TA with light TE TA with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode DA* Plug-in connector DK* DA with protection diode DL* DA with protection varistor * To be used with 82 Series only

174 Direct solenoid and solenoid pilot operated valves Series 6200 Individual mounting sub-base sub-base plug-in Manifold mounting sub-base sub-base plug-in A E X H. B.. EXH. CONDUIT

175 Direct solenoid and solenoid pilot operated valves Series 6200 Function Port size Flow (Max) Individual mounting 4/2-4/3 G1/4 - G3/ Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset xxxxx-xxx-pm-xxyzz Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre A A B B A A B B B A B A B A B A Valve less base EXH 6212C-000-PM-XXYZZ EXH 6222C-000-PM-XXYZZ EXH 6232C-000-PM-XXYZZ EXH 6242C-000-PM-XXYZZ sub-base Internal 6212C-171-PM-XXYZZ 6222C-171-PM-XXYZZ 6232C-171-PM-XXYZZ 6242C-171-PM-XXYZZ G1/4 External 6212C-181-PM-XXYZZ 6222C-181-PM-XXYZZ 6232C-181-PM-XXYZZ 6242C-181-PM-XXYZZ sub-base Internal 6212C-271-PM-XXYZZ 6222C-271-PM-XXYZZ 6232C-271-PM-XXYZZ 6242C-271-PM-XXYZZ G3/8 External 6212C-281-PM-XXYZZ 6222C-281-PM-XXYZZ 6232C-281-PM-XXYZZ 6242C-281-PM-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options O P T I O N S 6212C-000-PM-XXYZZ click for bottom cylinder ports (replace by 4).

176 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6200 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1,8 to 10 bar Double operator : 0,7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G1/4" : 1500 Nl/min (C v 1.5) - G3/8" : 1600 Nl/min (C v 1.6) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize :10 ms De-energize : 9ms 50Hz/6 W Energize : 7-13 ms De-energize :8-15 ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. DIMENSIONS 89,5 4,5 80,5 4 Ø 5,3 26,0 13,0 NI EXH 20,5 25,5 41,0 51,0 G 1/4" (OPTION) CYL A CYL A 162,8 DOUBLE OPERATOR 128,8 SGLE OPERATOR 56 ~31 85,0 18,0 10,0 EXH 13,0 4,0 21,3 29,0 G1/8 OPTIONAL PILOT EXH.

177 Direct solenoid and solenoid pilot operated valves Series 6200 Function Port size Flow (Max) Individual mounting 4/2-4/3 G1/4 - G3/ Nl/min sub-base plug-in OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset xxxxx-xxx-pm-xxyda Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre A A B B A A B B B A B A B A B A Valve less base EXH 6211C-000-PM-XXYDA EXH 6221C-000-PM-XXYDA EXH 6231C-000-PM-XXYDA EXH 6241C-000-PM-XXYDA sub-base Internal 6211C-151-PM-XXYDA 6221C-151-PM-XXYDA 6231C-151-PM-XXYDA 6241C-151-PM-XXYDA G1/4 External 6211C-161-PM-XXYDA 6221C-161-PM-XXYDA 6231C-161-PM-XXYDA 6241C-161-PM-XXYDA sub-base Internal 6211C-251-PM-XXYDA 6221C-251-PM-XXYDA 6231C-251-PM-XXYDA 6241C-251-PM-XXYDA G3/8 External 6211C-261-PM-XXYDA 6221C-261-PM-XXYDA 6231C-261-PM-XXYDA 6241C-261-PM-XXYDA SOLENOID OPERATOR XX Y DA * XX Voltage Y Manual operator V~/50Hz V~/50Hz 22 24V=/50Hz 1 Non-locking 2 Locking y Other Options 59 24V=/2,5W 87 24V=/17,1W 61 24V=/8,5W xx Other Options O P T I O N S 6211C-000-PM-XXYDA click for bottom cylinder ports (replace by 4). click for lights on valve (replace by 3).

178 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6200 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1,8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G1/4" : 1500 Nl/min (C v 1.5) - G3/8" : 1600 Nl/min (C v 1.6) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize :10 ms De-energize : 9ms 50Hz/6 W Energize : 7-13 ms De-energize :8-15 ms Solenoid operator (power 4 W) : D1-XXYDA1-BE, including mounting screws and seal Pilot valve : PME-XXYDA-BE, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. Lights in base. DIMENSIONS 162,8 128,8 94,2 31,0 27,0 19,5 80,2 48,9 EXH COND G1/8 OPTIONAL PILOT EXH. G1/8 EXT. PILOT 29,0 24,5 ISO 20 mm 29 74,5 39,8 54,0 27,0 NI A XE B C L 15,0 30,0 41,0 20,5 G1/4 (Option) 2 Ø 5,3

179 Direct solenoid and solenoid pilot operated valves Series 6200 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G1/4 - G3/ Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset xxxxx-xxx-pm-xxyzz Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre A A B B A A B B B A B A B A B A Valve less base EXH 6212C-000-PM-XXYZZ EXH 6222C-000-PM-XXYZZ EXH 6232C-000-PM-XXYZZ EXH 6242C-000-PM-XXYZZ sub-base Internal 6212C-471-PM-XXYZZ 6222C-471-PM-XXYZZ 6232C-471-PM-XXYZZ 6242C-471-PM-XXYZZ G1/4 External 6212C-481-PM-XXYZZ 6222C-481-PM-XXYZZ 6232C-481-PM-XXYZZ 6242C-481-PM-XXYZZ sub-base Internal 6212C-571-PM-XXYZZ 6222C-571-PM-XXYZZ 6232C-571-PM-XXYZZ 6242C-571-PM-XXYZZ G3/8 External 6212C-581-PM-XXYZZ 6222C-581-PM-XXYZZ 6232C-581-PM-XXYZZ 6242C-581-PM-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options O P T I O N S 6212C-000-PM-XXYZZ click for bottom cylinder ports (replace by 4). Fastening kit : N P

180 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6200 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G1/4" : 1500 Nl/min (C v 1.5) - G3/8" : 1600 Nl/min (C v 1.6) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize :10 ms De-energize : 9ms 50Hz/6 W Energize : 7-13 ms De-energize :8-15 ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : Tie rod (x2) : NPTF threads. DIMENSIONS 56,0 194,3 188,3 ~31,0 G1/8 OPTIONAL PILOT EXHAUST G1/4 EXT. PILOT 49,4 39,5 37,7 25,0 CYL B 20,0 19,0 CYL A G1/8 COMMON EXTERNAL PILOT (OPTION) 17,0 EXH G1/2 LET & EXHAUST Variante 2 Ø 6,5 101,5 COND 33,3 85,8 120,3 58,8 61,7 113,2 30,0 37,5 21,0 1 1/4 NPSM 45,0 28,5 15,0 CYL B CYL A NI C L 30,0 57,0 ± 0,2 19,0 14,0 84,3 OPTION (G3/8 )

181 Direct solenoid and solenoid pilot operated valves Series 6200 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G1/4 - G3/ Nl/min sub-base plug-in OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset xxxxx-xxx-pm-xxyda Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre A A B B A A B B B A B A B A B A Valve less base EXH 6211C-000-PM-XXYDA EXH 6221C-000-PM-XXYDA EXH 6231C-000-PM-XXYDA EXH 6241C-000-PM-XXYDA sub-base Internal 6211C-451-PM-XXYDA 6221C-451-PM-XXYDA 6231C-451-PM-XXYDA 6241C-451-PM-XXYDA G1/4 External 6211C-461-PM-XXYDA 6221C-461-PM-XXYDA 6231C-461-PM-XXYDA 6241C-461-PM-XXYDA sub-base Internal 6211C-551-PM-XXYDA 6221C-551-PM-XXYDA 6231C-551-PM-XXYDA 6241C-551-PM-XXYDA G3/8 External 6211C-561-PM-XXYDA 6221C-561-PM-XXYDA 6231C-561-PM-XXYDA 6241C-561-PM-XXYDA SOLENOID OPERATOR XX Y DA * XX Voltage Y Manual operator V~/50Hz V~/50Hz 22 24V=/50Hz 1 Non-locking 2 Locking y Other Options 59 24V=/2,5W 87 24V=/17,1W 61 24V=/8,5W xx Other Options O P T I O N S 6211C-000-PM-XXYDA click for bottom cylinder ports (replace by 4). click for lights on valve (replace by 3). Fastening kit : N P

182 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6200 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G1/4" : 1500 Nl/min (C v 1.5) - G3/8" : 1600 Nl/min (C v 1.6) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize : 10 ms De-energize : 9ms 50Hz/6 W Energize : 7-13 ms De-energize :8-15 ms Solenoid operator (power 4 W) : D1-XXYDA1-BE, including mounting screws and seal Pilot valve : PME-XXYDA-BE, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : Tie rod (x2) : NPTF threads. Lights in base. DIMENSIONS OPTION 2 Ø 6,5 19,0 101,5 58,8 45,0 28,5 15,0 CYL B CYL A NI C L 30,0 57,0 ± 0,2 19,0 14,0 84,3 OPTION (G3/8 ) 194,3 188,3 G1/4" EXT. PILOT 61,7 113,2 52,4 39,5 37,7 25,0 CYL A 20,0 CYL B EXH COND 30,0 37,5 21,0 G1/8 COMMON EXTERNAL PILOT (OPTION) 17,0 G1/2 LET & EXHAUST 85,8 120,3 33,3 1 1/4 NPSM

183 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

184 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

185 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

186 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

187 Direct solenoid and solenoid pilot operated valves Series 6300 Individual mounting sub-base sub-base plug-in Manifold mounting sub-base sub-base plug-in CYL. A EXH. CYL. B EXH. CONDUIT

188 Direct solenoid and solenoid pilot operated valves Series 6300 Function Port size Flow (Max) Individual mounting 4/2-4/3 G1/4 - G3/8 - G1/ Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxx-xxx-pm-xxyzz Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre A A B B A A B B B A B A B A B A Valve less base EXH 6312D-000-PM-XXYZZ EXH 6322D-000-PM-XXYZZ EXH 6332D-000-PM-XXYZZ EXH 6342D-000-PM-XXYZZ sub-base Internal 6312D-171-PM-XXYZZ 6322D-171-PM-XXYZZ 6332D-171-PM-XXYZZ 6342D-171-PM-XXYZZ G1/4 External 6312D-181-PM-XXYZZ 6322D-181-PM-XXYZZ 6332D-181-PM-XXYZZ 6342D-181-PM-XXYZZ sub-base Internal 6312D-271-PM-XXYZZ 6322D-271-PM-XXYZZ 6332D-271-PM-XXYZZ 6342D-271-PM-XXYZZ G3/8 External 6312D-281-PM-XXYZZ 6322D-281-PM-XXYZZ 6332D-281-PM-XXYZZ 6342D-281-PM-XXYZZ sub-base Internal 6312D-371-PM-XXYZZ 6322D-371-PM-XXYZZ 6332D-371-PM-XXYZZ 6342D-371-PM-XXYZZ G1/2 External 6312D-381-PM-XXYZZ 6322D-381-PM-XXYZZ 6332D-381-PM-XXYZZ 6342D-381-PM-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options O P T I O N S 6312D-000-PM-XXYZZ click for bottom cylinder ports (excluding G 1/2") (replace by 4). click for dual pressure valves (replace by 5).

189 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6300 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 9 to 11 mm G1/4" : 2000 Nl/min (C v 2.0) - G3/8" : 2600 Nl/min (C v 2.6) - G1/2" : 3000 Nl/min (C v 3.0) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize :10 ms De-energize : 11ms 50Hz/6 W Energize : 4-13 ms De-energize :10-17 ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. DIMENSIONS 171,8 137,1 56,0 88,7 ~31,0 96,4 26,5 15,0 EXH G1/8 (OPTION PILOT EXH.) C L 21,0 G1/8 EXT. PILOT 32,0

190 Direct solenoid and solenoid pilot operated valves Series 6300 Function Port size Flow (Max) Individual mounting 4/2-4/3 G1/4 - G3/8 - G1/ Nl/min sub-base plug-in OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxx-xxx-pm-xxyda Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre A A B B A A B B B A B A B A B A Valve less base EXH 6311D-000-PM-XXYDA EXH 6321D-000-PM-XXYDA EXH 6331D-000-PM-XXYDA EXH 6341D-000-PM-XXYDA sub-base Internal 6311D-151-PM-XXYDA 6321D-151-PM-XXYDA 6331D-151-PM-XXYDA 6341D-151-PM-XXYDA G1/4 External 6311D-161-PM-XXYDA 6321D-161-PM-XXYDA 6331D-161-PM-XXYDA 6341D-161-PM-XXYDA sub-base Internal 6311D-251-PM-XXYDA 6321D-251-PM-XXYDA 6331D-251-PM-XXYDA 6341D-251-PM-XXYDA G3/8 External 6311D-261-PM-XXYDA 6321D-261-PM-XXYDA 6331D-261-PM-XXYDA 6341D-261-PM-XXYDA sub-base Internal 6311D-351-PM-XXYDA 6321D-351-PM-XXYDA 6331D-351-PM-XXYDA 6341D-351-PM-XXYDA G1/2 External 6311D-361-PM-XXYDA 6321D-361-PM-XXYDA 6331D-361-PM-XXYDA 6341D-361-PM-XXYDA SOLENOID OPERATOR XX Y DA * XX Voltage Y Manual operator V~/50Hz V~/50Hz 1 Non-locking 2 Locking 22 24V~/50Hz 59 24V=/2,5W 87 24V=/17,1W 61 24V=/8,5W y Other Options xx Other Options O P T I O N S 6311D-000-PM-XXYDA click for bottom cylinder ports (excluding G 1/2") (replace by 4). click for lights on valve (replace by 3). click for dual pressure valves with lights on valve (replace by 6).

191 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6300 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 9 to 11 mm G1/4" : 2000 Nl/min (C v 2.0) - G3/8" : 2600 Nl/min (C v 2.6) - G1/2" : 3000 Nl/min (C v 3.0) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize :10 ms De-energize : 11ms 50Hz/6 W Energize : 4-13 ms De-energize :10-17 ms Solenoid operator (power 4 W) : D1-XXYDA1-BE, including mounting screws and seal Pilot valve : PME-XXYDA-BE, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. Lights in base. DIMENSIONS 32,0 C L CONDUIT 50,0 30,5 C L NI CYL A EXH CYL B C L 60,0 2 Ø 5,2 88,6 171,8 135,2 88,7 90,4 COND 26,5 15,0 EXH C L G1/8 (OPTION PILOT EXH.) G1/8 EXT. PILOT 32,0 42,0 ISO 20 mm

192 Direct solenoid and solenoid pilot operated valves Series 6300 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G3/8 - G1/ Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxx-xxx-pm-xxyzz Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A Valve less base EXH 6312D-000-PM-XXYZZ EXH 6322D-000-PM-XXYZZ EXH 6332D-000-PM-XXYZZ EXH 6342D-000-PM-XXYZZ EXH 6352D-000-PM-XXYZZ sub-base Internal 6312D-571-PM-XXYZZ 6322D-571-PM-XXYZZ 6332D-571-PM-XXYZZ 6342D-571-PM-XXYZZ 6352D-571-PM-XXYZZ G3/8 External 6312D-581-PM-XXYZZ 6322D-581-PM-XXYZZ 6332D-581-PM-XXYZZ 6342D-581-PM-XXYZZ 6352D-581-PM-XXYZZ Sur embase Internal 6312D-671-PM-XXYZZ 6322D-671-PM-XXYZZ 6332D-671-PM-XXYZZ 6342D-671-PM-XXYZZ 6352D-671-PM-XXYZZ G1/2 External 6312D-681-PM-XXYZZ 6322D-681-PM-XXYZZ 6332D-681-PM-XXYZZ 6342D-681-PM-XXYZZ 6352D-681-PM-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options O P T I O N S 6312D-000-PM-XXYZZ click for bottom cylinder ports (replace by 4). click for dual pressure valves (replace by 5). Fastening kit : N P

193 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6300 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0,7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 9 to 11 mm G3/8" : 2600 Nl/min (C v 2.6) - G1/2" : 3000 Nl/min (C v 3.0) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize :10 ms De-energize : 11ms 50Hz/6 W Energize : 4-13 ms De-energize :10-17 ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : Tie-rod (x2) : NPTF threads. DIMENSIONS 56,0 201,4 ~31,0 53,0 44,0 CYL'S EXH COND 112,1 G1/8 COMMON EXT PILOT (OPTION) 21,0 29,0 80,0 35,0 52,0 G3/4 199,6 G1/2 20,0 27,0 32,0 1 1/4 NPSM 41,0 24,0 101,0 G1/2 (OPTION) 5,0 ± 0,2 18,0 36,0 CYL B 62,0 ± 0,2 72,0 ± 0,2 CYL A 31,0 119,0 2 Ø 6,5

194 Direct solenoid and solenoid pilot operated valves Series 6300 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G3/8 - G1/ Nl/min sub-base plug-in OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxx-xxx-pm-xxyda Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A Valve less base EXH 6311D-000-PM-XXYDA EXH 6321D-000-PM-XXYDA EXH 6331D-000-PM-XXYDA EXH 6341D-000-PM-XXYDA EXH 6351D-000-PM-XXYDA sub-base Internal 6311D-551-PM-XXYDA 6321D-551-PM-XXYDA 6331D-551-PM-XXYDA 6341D-551-PM-XXYDA 6351D-551-PM-XXYDA G3/8 External 6311D-561-PM-XXYDA 6321D-561-PM-XXYDA 6331D-561-PM-XXYDA 6341D-561-PM-XXYDA 6351D-561-PM-XXYDA Sur embase Internal 6311D-651-PM-XXYDA 6321D-651-PM-XXYDA 6331D-651-PM-XXYDA 6341D-651-PM-XXYDA 6351D-651-PM-XXYDA G1/2 External 6311D-661-PM-XXYDA 6321D-661-PM-XXYDA 6331D-661-PM-XXYDA 6341D-661-PM-XXYDA 6351D-661-PM-XXYDA SOLENOID OPERATOR XX Y DA * Voltage V~/50Hz V~/50Hz Manual operator 1 Non-locking 2 Locking 22 24V~/50Hz 87 24V=/17,1W 59 24V=/2,5W 61 24V=/8,5W y Other Options xx Other Options O P T I O N S 6311D-000-PM-XXYDA click for bottom cylinder ports (replace by 4). click for lights on valve (replace by 3). click for dual pressure valves with lights on valve (replace by 6). Fastening kit : N P

195 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6300 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0,7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 9 to 11 mm G3/8" : 2600 Nl/min (C v 2.6) - G1/2" : 3000 Nl/min (C v 3.0) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize :10 ms De-energize : 11ms 50Hz/6 W Energize : 4-13 ms De-energize :10-17 ms Solenoid operator (power 4 W) : D1-XXYDA1-BE, including mounting screws and seal Pilot valve : PME-XXYDA-BE, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : Tie-rod (x2) : NPTF threads. Lights in base. DIMENSIONS 41,0 24,0 101,0 G1/2 (OPTION) 5,0 ± 0,2 18,0 36,0 CYL B 62,0 ± 0,2 72,0 ± 0,2 CYL A 31,0 119,0 2 Ø 6,5 201,4 53,0 44,0 CYL'S EXH COND 112,1 21,0 G1/8 COMMON EXT PILOT (OPTION) 29,0 80,0 35,0 52,0 199,6 3/4 1/2 20,0 27,0 32,0 1 1/4 NPSM

196 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

197 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

198 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

199 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

200 Direct solenoid and solenoid pilot operated valves Series 6500 Individual mounting sub-base sub-base plug-in Manifold mounting sub-base sub-base plug-in CYL. A EXH. CYL. B EXH. CONDUIT

201 Direct solenoid and solenoid pilot operated valves Series 6500 Function Port size Flow (Max) Individual mounting 4/2-4/3 G3/8 - G1/2 - G3/ Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxx-xxx-pm-xxyzz Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A Valve less base EXH 6512B-000-PM-XXYZZ EXH 6522B-000-PM-XXYZZ EXH 6532B-000-PM-XXYZZ EXH 6542B-000-PM-XXYZZ EXH 6552B-000-PM-XXYZZ sub-base Internal 6512B-171-PM-XXYZZ 6522B-171-PM-XXYZZ 6532B-171-PM-XXYZZ 6542B-171-PM-XXYZZ 6552B-171-PM-XXYZZ G3/8 External 6512B-181-PM-XXYZZ 6522B-181-PM-XXYZZ 6532B-181-PM-XXYZZ 6542B-181-PM-XXYZZ 6552B-181-PM-XXYZZ sub-base Internal 6512B-271-PM-XXYZZ 6522B-271-PM-XXYZZ 6532B-271-PM-XXYZZ 6542B-271-PM-XXYZZ 6552B-271-PM-XXYZZ G1/2 External 6512B-281-PM-XXYZZ 6522B-281-PM-XXYZZ 6532B-281-PM-XXYZZ 6542B-281-PM-XXYZZ 6552B-281-PM-XXYZZ sub-base Internal 6512B-371-PM-XXYZZ 6522B-371-PM-XXYZZ 6532B-371-PM-XXYZZ 6542B-371-PM-XXYZZ 6552B-371-PM-XXYZZ G3/4 External 6512B-381-PM-XXYZZ 6522B-381-PM-XXYZZ 6532B-381-PM-XXYZZ 6542B-381-PM-XXYZZ 6552B-381-PM-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options O P T I O N S 6512B-000-PM-XXYZZ click for dual pressure valve (replace by 4).

202 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6500 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 19 mm G3/8" : 4500 Nl/min (C v 4.5) - G1/2" : 5000 Nl/min (C v 5.0) - G3/4" : 5100 Nl/min (C v 5.1) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V = /8,5 W Energize : 12 ms De-energize : 12 ms 50 Hz / 6 W Energize : 9-14 ms De-energize : ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. DIMENSIONS 2 Ø 6,7 101,6 A/2 EXH 29,7 A CYL A CYL B 20,6 41,3 59,4 17,3 34,9 56,0 190,3 157,1 ~31,0 B C J G EXH H Port size A B C E F G H J G1/8 EXT. PILOT F E 67,3 G3/8 - G1/2 69,6 97,4 18,3 36,0 17,9 19,0 23,6 25,4 G3/4 94,5 109,3 17,3 40,1 19,2 20,8 35,9 36,6

203 Direct solenoid and solenoid pilot operated valves Series 6500 Function Port size Flow (Max) Individual mounting 4/2-4/3 G3/8 - G1/2 - G3/ Nl/min sub-base plug-in OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxx-xxx-pm-xxyda Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A Valve less base EXH 6511B-000-PM-XXYDA EXH 6521B-000-PM-XXYDA EXH 6531B-000-PM-XXYDA EXH 6541B-000-PM-XXYDA EXH 6551B-000-PM-XXYDA sub-base Internal 6511B-151-PM-XXYDA 6521B-151-PM-XXYDA 6531B-151-PM-XXYDA 6541B-151-PM-XXYDA 6551B-151-PM-XXYDA G3/8 External 6511B-161-PM-XXYDA 6521B-161-PM-XXYDA 6531B-161-PM-XXYDA 6541B-161-PM-XXYDA 6551B-161-PM-XXYDA sub-base Internal 6511B-251-PM-XXYDA 6521B-251-PM-XXYDA 6531B-251-PM-XXYDA 6541B-251-PM-XXYDA 6551B-251-PM-XXYDA G1/2 External 6511B-261-PM-XXYDA 6521B-261-PM-XXYDA 6531B-261-PM-XXYDA 6541B-261-PM-XXYDA 6551B-261-PM-XXYDA sub-base Internal 6511B-351-PM-XXYDA 6521B-351-PM-XXYDA 6531B-351-PM-XXYDA 6541B-351-PM-XXYDA 6551B-351-PM-XXYDA G3/4 External 6511B-361-PM-XXYDA 6521B-361-PM-XXYDA 6531B-361-PM-XXYDA 6541B-361-PM-XXYDA 6551B-361-PM-XXYDA SOLENOID OPERATOR XX Y DA * XX Voltage Y Manual operator V~/50Hz V~/50Hz 22 24V~/50Hz 1 Non-locking 2 Locking y Other Options 59 24V=/2,5W 87 24V=/17,1W 61 24V=/8,5W xx Other Options O P T I O N S 6511B-000-PM-XXYDA click for dual pressure valve (replace by 4). click for lights on valve (replace by 3).

204 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6500 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 19 mm G3/8" : 4500 Nl/min (C v 4.5) - G1/2" : 5000 Nl/min (C v 5.0) - G3/4" : 5100 Nl/min (C v 5.1) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize :12 ms De-energize : 12ms 50Hz/6 W Energize : 9-14 ms De-energize :11-18 ms Solenoid operator (power 4 W) : D1-XXYDA1-BE, including mounting screws and seal Pilot valve : PME-XXYDA-BE, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. Lights in base. DIMENSIONS 2 Ø 6,7 93,9 A/2 EXH 29,7 A CYL A CYL B 20,6 41,3 59,4 17,3 34,9 190,3 156,0 B G C J EXH COND Port size A B C D E F G H J G1/8 EXT. PILOT F E D ISO 20 mm G3/8 - G1/2 69,6 97,4 18,3 40,6 36,0 17,9 19,0 23,6 25,4 G3/4 94,5 109,3 17,3 46,7 40,1 19,2 20,8 35,9 36,6

205 Direct solenoid and solenoid pilot operated valves Series 6500 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G3/8 - G1/2 - G3/ Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxx-xxx-pm-xxyzz Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A Valve less base EXH 6512B-000-PM-XXYZZ EXH 6522B-000-PM-XXYZZ EXH 6532B-000-PM-XXYZZ EXH 6542B-000-PM-XXYZZ EXH 6552B-000-PM-XXYZZ sub-base Internal 6512B-471-PM-XXYZZ 6522B-471-PM-XXYZZ 6532B-471-PM-XXYZZ 6542B-471-PM-XXYZZ 6552B-471-PM-XXYZZ G3/8 External 6512B-481-PM-XXYZZ 6522B-481-PM-XXYZZ 6532B-481-PM-XXYZZ 6542B-481-PM-XXYZZ 6552B-481-PM-XXYZZ sub-base Internal 6512B-571-PM-XXYZZ 6522B-571-PM-XXYZZ 6532B-571-PM-XXYZZ 6542B-571-PM-XXYZZ 6552B-571-PM-XXYZZ G1/2 External 6512B-581-PM-XXYZZ 6522B-581-PM-XXYZZ 6532B-581-PM-XXYZZ 6542B-581-PM-XXYZZ 6552B-581-PM-XXYZZ sub-base Internal 6512B-671-PM-XXYZZ 6522B-671-PM-XXYZZ 6532B-671-PM-XXYZZ 6542B-671-PM-XXYZZ 6552B-671-PM-XXYZZ G3/4 External 6512B-681-PM-XXYZZ 6522B-681-PM-XXYZZ 6532B-681-PM-XXYZZ 6542B-681-PM-XXYZZ 6552B-681-PM-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options O P T I O N S 6512B-000-PM-XXYZZ click for dual pressure valve (replace by 4). Fastening kit : N P

206 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6500 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 19 mm G3/8" : 4500 Nl/min (C v 4.5) - G1/2" : 5000 Nl/min (C v 5.0) - G3/4" : 5100 Nl/min (C v 5.1) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize : 12 ms De-energize : 12 ms 50Hz/6 W Energize : 9-14 ms De-energize :11-18 ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : Tie-rod (x2) : NPTF threads. DIMENSIONS G1/8 EXT. PILOT 2 Ø 6,7 42,3 60,0 79,0 16,8 78,0 44,5 CYL A CYL B A B 26,5 24,0 89,0 82,0 59,6 5, ,6 200,3 185,3 40 CYL A EXH COND. 132,8 61,0 50,5 48,0 50,0 CYL B 22,0 20,5 G1 G3/4 41,5 44,5 34,5 1 1/4 NPSM

207 Direct solenoid and solenoid pilot operated valves Series 6500 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G3/8 - G1/2 - G3/ Nl/min sub-base plug-in OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxx-xxx-pm-xxyda Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A Valve less base EXH 6511B-000-PM-XXYDA EXH 6521B-000-PM-XXYDA EXH 6531B-000-PM-XXYDA EXH 6541B-000-PM-XXYDA EXH 6551B-000-PM-XXYDA sub-base Internal 6511B-451-PM-XXYDA 6521B-451-PM-XXYDA 6531B-451-PM-XXYDA 6541B-451-PM-XXYDA 6551B-451-PM-XXYDA G3/8 External 6511B-461-PM-XXYDA 6521B-461-PM-XXYDA 6531B-461-PM-XXYDA 6541B-461-PM-XXYDA 6551B-461-PM-XXYDA sub-base Internal 6511B-551-PM-XXYDA 6521B-551-PM-XXYDA 6531B-551-PM-XXYDA 6541B-551-PM-XXYDA 6551B-551-PM-XXYDA G1/2 External 6511B-561-PM-XXYDA 6521B-561-PM-XXYDA 6531B-561-PM-XXYDA 6541B-561-PM-XXYDA 6551B-561-PM-XXYDA sub-base Internal 6511B-651-PM-XXYDA 6521B-651-PM-XXYDA 6531B-651-PM-XXYDA 6541B-651-PM-XXYDA 6551B-651-PM-XXYDA G3/4 External 6511B-661-PM-XXYDA 6521B-661-PM-XXYDA 6531B-661-PM-XXYDA 6541B-661-PM-XXYDA 6551B-661-PM-XXYDA SOLENOID OPERATOR XX Y DA * XX Voltage Y Manual operator V~/50Hz V~/50Hz 22 24V~/50Hz 1 Non-locking 2 Locking y Other Options 59 24V=/2,5W 87 24V=/17,1W 61 24V=/8,5W xx Other Options O P T I O N S 6511B-000-PM-XXYDA click for dual pressure valve (replace by 4). click for lights on valve (replace by 3). Fastening kit : N P

208 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6500 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positons : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 19 mm G3/8" : 4500 Nl/min (C v 4.5) - G1/2" : 5000 Nl/min (C v 5.0) - G3/4" : 5100 Nl/min (C v 5.1) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize :12 ms De-energize : 12ms 50Hz/6 W Energize : 9-14 ms De-energize :11-18 ms Solenoid operator (power 4 W) : D1-XXYDA1-BE, including mounting screws and seal Pilot valve : PME-XXYDA-BE, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : Tie-rod (x2) : NPTF threads. Lights in base. DIMENSIONS G1/8 EXT. PILOT 2 Ø 6,7 42,3 60,0 79,0 16,8 78,0 44,5 CYL A CYL B A B 26,5 24,0 89,0 82,0 59,6 5,5 206,6 200,3 185,3 CYL A EXH COND. 132,8 61,0 50,5 48,0 50,0 CYL B 22,0 20,5 G1 G3/4 41,5 44,5 34,5 1 1/4 NPSM

209 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

210 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

211 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

212 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

213 Direct solenoid and solenoid pilot operated valves Series 6600 Individual mounting sub-base sub-base plug-in Manifold mounting sub-base sub-base plug-in CYL. B EXH. CYL. A EXH.

214 Direct solenoid and solenoid pilot operated valves Series 6600 Function Port size Flow (Max) Individual mounting 4/2-4/3 G3/4 - G Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxx-xxx-pm-xxyzz Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A Valve less base EXH 6612A-000-PM-XXYZZ EXH 6622A-000-PM-XXYZZ EXH 6632A-000-PM-XXYZZ EXH 6642A-000-PM-XXYZZ EXH 6652A-000-PM-XXYZZ sub-base Internal 6612A-271-PM-XXYZZ 6622A-271-PM-XXYZZ 6632A-271-PM-XXYZZ 6642A-271-PM-XXYZZ 6652A-271-PM-XXYZZ G3/4 External 6612A-281-PM-XXYZZ 6622A-281-PM-XXYZZ 6632A-281-PM-XXYZZ 6642A-281-PM-XXYZZ 6652A-281-PM-XXYZZ sub-base Internal 6612A-371-PM-XXYZZ 6622A-371-PM-XXYZZ 6632A-371-PM-XXYZZ 6642A-371-PM-XXYZZ 6652A-371-PM-XXYZZ G1 External 6612A-381-PM-XXYZZ 6622A-381-PM-XXYZZ 6632A-381-PM-XXYZZ 6642A-381-PM-XXYZZ 6652A-381-PM-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options

215 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6600 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 24 mm G3/4" : 9000 Nl/min (C v 9.0) - G1" : 9600 Nl/min (C v 9.6) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize : 18 ms De-energize : 20 ms 50Hz/6 W Energize : ms De-energize : ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. DIMENSIONS 56 DBL 239,8 SGL 203,9 G1/8 EXTERNAL PILOT G1/8 EXTERNAL PILOT 137,4 P-A P-B G1/2 LET FOR DUAL PRESSURE 59,0 37,0 24,0 EXH 60,0 45,0 24,0 60,0 1/2 NPSM CONDUIT 40,0 51,0 49,0 20,0 53,0 15,0 5,0 35,0 40,0 Ø 10,32 2 MTG HOLES 86,0 28,0 43,0 28,0 C L B EX A 24,0 22,0 53,0 106,0 G3/4 OPTIONAL BOTTOM PORTS 20,0 CYL B CYL A 11,0 55,0 27,0 51,0 110,0 G1/8 OPTIONAL BOTTOM EXTERNAL PILOT

216 Direct solenoid and solenoid pilot operated valves Series 6600 Function Port size Flow (Max) Individual mounting 4/2-4/3 G3/4 - G Nl/min sub-base plug-in OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxx-xxx-pm-xxyda Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A Valve less base EXH 6611A-000-PM-XXYDA EXH 6621A-000-PM-XXYDA EXH 6631A-000-PM-XXYDA EXH 6641A-000-PM-XXYDA EXH 6651A-000-PM-XXYDA sub-base Internal 6611A-251-PM-XXYDA 6621A-251-PM-XXYDA 6631A-251-PM-XXYDA 6641A-251-PM-XXYDA 6651A-251-PM-XXYDA G3/4 External 6611A-261-PM-XXYDA 6621A-261-PM-XXYDA 6631A-261-PM-XXYDA 6641A-261-PM-XXYDA 6651A-261-PM-XXYDA sub-base Internal 6611A-351-PM-XXYDA 6621A-351-PM-XXYDA 6631A-351-PM-XXYDA 6641A-351-PM-XXYDA 6651A-351-PM-XXYDA G1 External 6611A-361-PM-XXYDA 6621A-361-PM-XXYDA 6631A-361-PM-XXYDA 6641A-361-PM-XXYDA 6651A-361-PM-XXYDA SOLENOID OPERATOR XX Y DA * XX Voltage Y Manual operator V~/50Hz V~/50Hz 1 Non-locking 2 Locking 22 24V~/50Hz 59 24V=/2,5W 87 24V=/17,1W 61 24V=/8,5W y Other Options xx Other Options O P T I O N S 6611A-000-PM-XXYDA click for lights on valve (replace by 3).

217 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6600 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 24 mm G3/4" : 9000 Nl/min (C v 9.0) - G1" : 9600 Nl/min (C v 9.6) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize : 18 ms De-energize : 20 ms 50Hz/6 W Energize : ms De-energize : ms Solenoid operator (power 4 W) : D1-XXYDA1-BE, including mounting screws and seal Pilot valve : PME-XXYDA-BE, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. Lights in base. DIMENSIONS 203,9 239,8 G1/8 EXTERNAL PILOT G1/8 EXTERNAL PILOT 137,4 P-A P-B G1/2 LET FOR DUAL PRESSURE 59,0 37,0 24,0 EXH 60,0 45,0 24,0 60,0 1/2 NPSM CONDUIT 40,0 51,0 49,0 20,0 53,0 15,0 5,0 35,0 40,0 Ø 10,32 2 MTG HOLES 86,0 28,0 43,0 28,0 C L B EX A 24,0 22,0 53,0 106,0 G3/4 OPTIONAL BOTTOM PORTS 20,0 CYL B CYL A 11,0 55,0 27,0 G1/8 OPTIONAL BOTTOM EXTERNAL PILOT 51,0 110,0

218 Direct solenoid and solenoid pilot operated valves Series 6600 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G3/4 - G1 - G1 1/ Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxx-xxx-pm-xxyzz Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A Valve less base EXH 6612A-000-PM-XXYZZ EXH 6622A-000-PM-XXYZZ EXH 6632A-000-PM-XXYZZ EXH 6642A-000-PM-XXYZZ EXH 6652A-000-PM-XXYZZ sub-base Internal 6612A-471-PM-XXYZZ 6622A-471-PM-XXYZZ 6632A-471-PM-XXYZZ 6642A-471-PM-XXYZZ 6652A-471-PM-XXYZZ G3/4 External 6612A-481-PM-XXYZZ 6622A-481-PM-XXYZZ 6632A-481-PM-XXYZZ 6642A-481-PM-XXYZZ 6652A-481-PM-XXYZZ sub-base Internal 6612A-571-PM-XXYZZ 6622A-571-PM-XXYZZ 6632A-571-PM-XXYZZ 6642A-571-PM-XXYZZ 6652A-571-PM-XXYZZ G1 External 6612A-581-PM-XXYZZ 6622A-581-PM-XXYZZ 6632A-581-PM-XXYZZ 6642A-581-PM-XXYZZ 6652A-581-PM-XXYZZ sub-base Internal 6612A-671-PM-XXYZZ 6622A-671-PM-XXYZZ 6632A-671-PM-XXYZZ 6642A-671-PM-XXYZZ 6652A-671-PM-XXYZZ G1 1/4 External 6612A-681-PM-XXYZZ 6622A-681-PM-XXYZZ 6632A-681-PM-XXYZZ 6642A-681-PM-XXYZZ 6652A-681-PM-XXYZZ SOLENOID OPERATOR XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options Fastening kit : N P

219 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6600 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 24 mm G3/4" : 9000 Nl/min (C v 9.0) - G1" : 9600 Nl/min (C v 9.6) - G1 1/4" : 9600 Nl/min (C v 9.6) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize : 18 ms De-energize : 20 ms 50 Hz/6 W Energize : ms De-energize : ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : Tie-rod (x2) : NPTF threads. DIMENSIONS 353 DOUBLE OPERATOR 119,9 70,0 ~31 STANDARD COMMON EXTERNAL PILOT SUPPLY G1/8 11,8 OPTIONAL DIVIDUAL EXTERNAL PILOT SUPPLY G1/8 156,9 CYL A 161,4 CYL B 60,0 32,0 EXH CONDUIT 40,5 50,5 67,5 81,5 22,0 52,0 50,0 108,0 ± 0,2 G1 1/4 LET & EXHAUST 12,0 50,0 54,0 129,8 287,5 1 NPSM CONDUIT PORT OPTIONAL G3/4 & G1 BOTTOM CYLDER PORTS AVAILABLE 48,0 42,0 Ø 10,32 2 MTG HOLES CYL B 54,0 129,8 24,0 CYL A 129,8 30,0 56,0 169,0 ± 0,1 G1 1/4 BOTTOM LET PORT - OPTIONAL

220 Direct solenoid and solenoid pilot operated valves Series 6600 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G3/4 - G1 - G1 1/ Nl/min sub-base plug-in OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxx-xxx-pm-xxyda Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A Valve less base EXH 6611A-000-PM-XXYDA EXH 6621A-000-PM-XXYDA EXH 6631A-000-PM-XXYDA EXH 6641A-000-PM-XXYDA EXH 6651A-000-PM-XXYDA sub-base Internal 6611A-451-PM-XXYDA 6621A-451-PM-XXYDA 6631A-451-PM-XXYDA 6641A-451-PM-XXYDA 6651A-451-PM--XXYDA G3/4 External 6611A-461-PM-XXYDA 6621A-461-PM-XXYDA 6631A-461-PM-XXYDA 6641A-461-PM-XXYDA 6651A-461-PM-XXYDA sub-base Internal 6611A-551-PM-XXYDA 6621A-551-PM-XXYDA 6631A-551-PM-XXYDA 6641A-551-PM-XXYDA 6651A-551-PM-XXYDA G1 External 6611A-561-PM-XXYDA 6621A-561-PM-XXYDA 6631A-561-PM-XXYDA 6641A-561-PM-XXYDA 6651A-561-PM-XXYDA sub-base Internal 6611A-651-PM-XXYDA 6621A-651-PM-XXYDA 6631A-651-PM-XXYDA 6641A-651-PM-XXYDA 6651A-651-PM-XXYDA G1 1/4 External 6611A-661-PM-XXYDA 6621A-661-PM-XXYDA 6631A-661-PM-XXYDA 6641A-661-PM-XXYDA 6651A-661-PM-XXYDA SOLENOID OPERATOR XX Y DA * XX Voltage Y Manual operator V~/50Hz V~/50Hz 1 Non-locking 2 Locking 22 24V~/50Hz 59 24V=/2,5W 87 24V=/17,1W 61 24V=/8,5W y Other Options xx Other Options O P T I O N S 6611A-000-PM-XXYDA click for lights on valve (replace by 3). Fastening kit : N P

221 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6600 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions: 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 24 mm G3/4" : 9000 Nl/min (Cv9.0) - G1" : 9600 Nl/min (Cv9.6) - G1 1/4" : 9600 Nl/min (Cv9.6) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA Holding : 10.9 VA = 1 to 17.1 W 24 V=/8.5 W Energize : 18 ms De-energize : 20 ms 50Hz/6 W Energize : ms De-energize :19-28 ms Solenoid operator (power 4 W) : D1-XXYDA1-BE, including mounting screws and seal Pilot valve : PME-XXYDA-BE, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : Tie-rod (x2) : NPTF threads. Lights in base. DIMENSIONS 249,7 DOUBLE OPERATOR 119,9 70,0 STANDARD COMMON EXTERNAL PILOT SUPPLY G1/8 11,8 OPTIONAL DIVIDUAL EXTERNAL PILOT SUPPLY PORT G1/8 CYL A 161,4 CYL B 60,0 32,0 EXH CONDUIT 40,5 50,5 67,5 81,5 22,0 52,0 50,0 108,0 ± 0,2 G1 1/4 LET & EXHAUST 12,0 50,0 54,0 129,8 237,8 SGLE OPERATOR 1 NPSM CONDUIT PORT OPTIONAL G3/4 & G1 BOTTOM CYLDER PORTS AVAILABLE 48,0 42,0 Ø 10,32 2 MTG HOLES CYL B 54,0 129,8 24,0 CYL A 129,8 30,0 56,0 169,0 ± 0,1 G1 1/4 BOTTOM LET PORT - OPTIONAL

222 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

223 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

224 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

225 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

226 Direct solenoid and solenoid pilot operated valves Series 1300 Individual mounting sub-base plug-in EXH. CYL. B CYL. A EXH. EXH.

227 Direct solenoid and solenoid pilot operated valves Series 1300 Function Port size Flow (Max) Individual mounting 4/2-4/3 G3/4 - G1 - G1 1/4 - G1 1/ Nl/min sub-base plug-in OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. High shifting forces. 4. Checked accumulator guarantees maximum pilot pressure. 5. Powerful return force thanks to the combination of mechanical and air springs. 6. Bonded spool with minimum friction, shifting in a glass-like finished bore. 7. Wiping effect eliminates sticking. 8. Pilot valve with balanced poppet, high flow, short and consistent response times. HOW TO ORDER Reset xxxxg-xxyda-xx Port size 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre A A B B A A B B B A B A B A B A Valve less base EXH 1301G-XXYDA-XX EXH 1303G-XXYDA-XX EXH 1307G-XXYDA-XX EXH 1308G-XXYDA-XX Su base G 3/4 1321G-XXYDA-XX 1323G-XXYDA-XX 1327G-XXYDA-XX 1328G-XXYDA-XX Su base G G-XXYDA-XX 1333G-XXYDA-XX 1337G-XXYDA-XX 1338G-XXYDA-XX Su base G1 1/4 1351G-XXYDA-XX 1353G-XXYDA-XX 1357G-XXYDA-XX 1358G-XXYDA-XX Su base G1 1/2 1361G-XXYDA-XX 1363G-XXYDA-XX 1367G-XXYDA-XX 1368G-XXYDA-XX SOLENOID OPERATOR XX Y DA- X X * XX Voltage Y Manual operator X Pilot air X Indicator light V~/50Hz 1 Non-locking 3 Internal 5 With light in base V~/50Hz 2 Locking 4 External 22 24V~/50Hz y Other Options 87 24V=/17,1W 59 24V=/2,5W 61 24V=/8,5W xx Other Options

228 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 1300 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar. Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 35 mm G3/4" : Nl/min (C v 11.5) - G1" : Nl/min (C v 13.7) - G1 1/4" : Nl/min (C v 15.4) - G1 1/2" : Nl/min (C v 15.9) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize : 20 ms De-energize : 28ms 50Hz/6 W Energize : ms De-energize :29-35 ms Solenoid operator (power 4 W) : D1-XXBD. Pressure seal between valve and base : Pilot valve : 150B-XXBD, including mounting screws and adaptor plate N Mounting screw valve to base (x4) : NPTF threads. Lights in base. DIMENSIONS 272,7 DOUBLE OPERATOR 237,9 SGLE OPERATOR 136,4 79,2 158,8 CYL A CYL B OPTIONAL BOTTOM PORTS G3/4 MODELS ONLY A B CONDUIT EXT PILOT A 76,2 63,5 B B A C 17,5 EXH 19,8 4 Ø 10,4 MTG. HOLES EXH CONDUIT D E F 3 HOLES 1/2 NPSM CONDUIT Port size A B C D E F G3/4 111,3 132,4 23,8 31,7 63,5 71,4 G1 1/4 G1 1/2 114,3 148,3 30,2 38,1 35,0 76,2 69,9 65,0 68,0

229 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

230 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

231 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

232 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

233 Direct solenoid and solenoid pilot operated valves Series 44 Individual mounting inline Circuit bar mounting cylinder ports in base cylinder ports in valve B A EB EA

234 Direct solenoid and solenoid pilot operated valves Series 44 Function Port size Flow (Max) Individual mounting 5/2 M5 100 Nl/min inline OPERATIONAL BENEFITS mm valve, direct solenoid operated. 2. Balanced poppet, immune to variations of pressure. 3. Short stroke with high flow. 4. The patended solenoid develops high shifting forces. 5. Powerful return spring. 6. Flow is specifically adjusted on each valve. 7. Manual operator standard on all valves. HOW TO ORDER Reset 44A-xxx-Gxxx-xxx PRESSURE RANGE : 0 TO 8.5 BAR Port size Universal valve For use with external flow regulators B A B A M5 EB EA 44A-ABA-GXXX-XXX EB EA 44A-BBA-GXXX-XXX SOLENOID OPERATOR G XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection DA 24V=/1W A 45 cm 1 Non-locking BA Flying leads DC 24V=/1,8W C 92 cm BT Flying leads with light DD 24V=/2,5W x Other Options KA Mini connector DF 24V=/4W KT Mini connector with light xx Other Options xx Other Options

235 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 44 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 1.8 mm 4 W : 100Nl/min (C v 0.1) W : 80 Nl/min (C v 0.08) W : 60 Nl/min (C v 0.06) W: 50 Nl/min (C v 0.05) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED -15% to +10% of nominal voltage IP 54 4 W W W W Energize : 3.5 ms De-energize : 1.5 ms Note : Valve and coil are not interchangeable. DIMENSIONS Ø 3,3 MTG. HOLES 31,5 C L C L A B EB EA 5,0 15,0 C L 3,5 59,9 20,0 10,0 29,7 13,0 20,0 10,0 5,0 15,0 25,0 5,0 10,0 5,7

236 Direct solenoid and solenoid pilot operated valves Series 44 Function Port size Flow (Max) Circuit bar mounting 5/2 M5 80 Nl/min cylinder ports in base OPERATIONAL BENEFITS mm valve, direct solenoid operated. 2. Balanced poppet, immune to variations of pressure. 3. Short stroke with high flow. 4. The patended solenoid develops high shifting forces. 5. Powerful return spring. 6. Flow is specifically adjusted on each valve. 7. Manual operator standard on all valves. HOW TO ORDER Reset 44A-xxx-Gxxx-xxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Port size (see base) Universal valve For use with external flow regulators B A B A Valve less base EB EA 44A-LOO-GXXX-XXX EB EA 44A-MOO-GXXX-XXX SOLENOID OPERATOR G XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection DA 24V=/1W A 45 cm 1 Non-locking BA Flying leads DC 24V=/1,8W C 92 cm BT Flying leads with light DD 24V=/2,5W x Other Options KA Mini connector DF 24V=/4W KT Mini connector with light xx Other Options xx Other Options HOW TO ORDER CIRCUIT BAR** Port size M5 EBP44A-xxxx-xx Side cylinder ports EBP44A-001D-XX Bottom cylinder ports EBP44A-002D-XX * * Other options available. Consult factory. XX = Number of stations (03=3 stations) Note : click for valves mounted on base at the factory (add - 9 to the model number).

237 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 44 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 1.8 mm 4 W : 80Nl/min (C v 0.08) W : 60 Nl/min (C v 0.06) W : 40 Nl/min (C v 0.04) W : 30 Nl/min (C v 0.03) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED -15% to +10% of nominal voltage IP 54 4 W W W W Energize : 3.4 ms De-energize : 1.5 ms Note : Spare parts : Options : Valve and coil are not interchangeable. Valve mounting kit : N Blanking plate : A. Isolation of inlet and/or exhaust. DIMENSIONS M5 VALVE MTG. SCR. 24,8 59,5 10,0 B B 16,25 5,3 15,0 A A 15,0 71,2 15,5 2,5 15,5 10,5 5,0 EA EB 15,5 10,5 10,5 G1/8 PORTS 18,3 44,8 5,5 4 Ø 4,3 56,3 57,3

238 Direct solenoid and solenoid pilot operated valves Series 44 Function Port size Flow (Max) Circuit bar mounting 5/2 M5 80 Nl/min cylinder ports in valve OPERATIONAL BENEFITS mm valve, direct solenoid operated. 2. Balanced poppet, immune to variations of pressure. 3. Short stroke with high flow. 4. The patended solenoid develops high shifting forces. 5. Powerful return spring. 6. Flow is specifically adjusted on each valve. 7. Manual operator standard on all valves. HOW TO ORDER Reset 44A-xxx-Gxxx-xxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Port size M5 Universal valve For use with external flow regulators B A B A Valve less base EB EA 44A-ABA-GXXX-XXX EB EA 44A-BBA-GXXX-XXX SOLENOID OPERATOR G XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection DA 24V=/1W A 45 cm 1 Non-locking BA Flying leads DC 24V=/1,8W C 92 cm BT Flying leads with light DD 24V=/2,5W x Other Options KA Mini connector DF 24V=/4W KT Mini connector with light xx Other Options xx Other Options HOW TO ORDER CIRCUIT BAR** EBM44A-xxxx-xx Port size M5 G1/8 EBM44A-001D-XX EBM44A-002C-XX * * Other options available. Consult factory. XX = Number of stations (03=3 stations) Note : click for valves mounted on base at the factory (add - 9 to the model number).

239 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 44 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : (with 4 W coil) Compressed air, vacuum, inert gases Vacuum to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 1.8 mm 4 W : 80Nl/min (C v 0.08) W : 60 Nl/min (C v 0.06) W : 40 Nl/min (C v 0.04) W : 30 Nl/min (C v 0.03) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED -15% to +10% of nominal voltage IP 54 4 W W W W Energize : 3.5 ms De-energize : 1.5 ms Note : Spare parts : Options : Valve and coil are not interchangeable. Valve mounting kit (M5) : M Valve mounting kit (G1/8") : M Isolation of inlet and/or exhaust. DIMENSIONS J K A B B Ø 4,2 MTG. HOLES H A D E F G 14,0 C L C L 10,50 4,00 C 38,5 Port size A B C D E F G H J K G1/8 16,0 47,5 69,2 8,5 24,0 39,5 48,0 8,0 31,85 16,15 M5 12,0 43,5 63,2 5,0 17,0 29,0 34,0 6,0 23,00 11,00

240 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection VALVE CODE - G XX X - 1 XX OPTIONS AVAILABLE FOR - solenoid valves 34 & 44 Series

241 OPTIONS Back 1. VOLTAGE (type 34 Series) -G XX X - 1 XX VOLTAGE DC 24 V=/1,8 W DD 24 V=/2,5 W DE 24 V=/3,0 W DF 24 V=/4,0 W DJ 12 V=/1,8 W DK 12 V=/2,5 W DM 12 V=/3,0 W DN 12 V=/4,0 W ED 120 V~/50 Hz (2,5 W) 1. VOLTAGE (type 44 Series) -G XX X - 1 XX VOLTAGE DA 24 V=/1,0 W DC 24 V=/1,8 W DD 24 V=/2,5 W DF 24 V=/4,0 W DG 12 V=/1,0 W DJ 12 V=/1,8 W DK 12 V=/2,5 W DN 12 V=/4,0 W ED 120 V~/50 Hz (2,5 W) 2. WIRE LENGTH (Common options for 34 & 44 Series) -G XX X - 1 XX WIRE LENGTH A 45 cm - 18 B 60 cm - 24 C 90 cm - 36 D 120 cm - 48 E 180 cm - 72 F 240 cm - 96 G 305 cm H 366 cm - 144

242 O p t i o n s OPTIONS Back 3. MANUAL OPERATOR -G XX X - 1 XX MANUAL OPERATOR 1 Non-locking recessed 4. ELECTRICAL CONNECTION -G XX X - 1 XX NO CONNECTOR BA Flying leads BB BA with ground wire BC BA with light BD BA with light and ground wire BE BA with suppression diode BF BA with suppression diode and ground wire BG BA with suppression diode and light BH BA with suppression diode, light and ground wire BN BA with suppression diode and blocking diode BP BA with suppression diode, blocking diode and ground wire BR BA with suppression diode, blocking diode and light BS BA with suppression diode, blocking diode, light and ground wire BT BA with light BU BA with light and ground wire BV BA with suppression diode and light BW BA with suppression diode, light and ground wire BX BA with suppression diode, blocking diode and light BY BA with suppression diode, blocking diode, light and ground wire -G XX X - 1 XX PLUG- CONNECTOR KA Mini connector with flying leads KB KA with ground wire KE KA with suppression diode KF KA with suppression diode and ground wire KJ Mini connector for KA option KM Mini connector for KB option KN KA with suppression diode and blocking diode KP KA with suppression diode, blocking diode and ground wire KT KA with light KU KA with light and ground wire KV KA with suppression diode and light KW KA with suppression diode, light and ground wire KX KA with suppression diode, blocking diode and light KY KA with suppression diode, blocking diode, light and ground wire

243 Direct solenoid and solenoid pilot operated valves Series 400 Individual mounting inline Circuit bar mounting cylinder ports in base cylinder ports in valve

244 Direct solenoid and solenoid pilot operated valves Series 400 Function Port size Flow (Max) Individual mounting 5/2-5/3 G1/8 - G1/ Nl/min inline OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways. 2. Memory spring available. 3. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow, short and consistent response times. 7. Wiping effect eliminates sticking. 8. Long service life. HOW TO ORDER Reset xxxx-xxx-dm-dxxx-xxx SGLE PRESSURE VALVES Port size Pilot air 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre 5/3 Pressure centre G1/8 Internal A-COA-DM-DXXX-XXX A-COA-DM-DXXX-XXX A-COA-DM-DXXX-XXX A-COA-DM-DXXX-XXX A-COA-DM-DXXX-XXX G1/4 411A-DOA-DM-DXXX-XXX 421A-DOA-DM-DXXX-XXX 451A-DOA-DM-DXXX-XXX 461A-DOA-DM-DXXX-XXX 471A-DOA-DM-DXXX-XXX G1/8 External 411A-COB-DM-DXXX-XXX 421A-COB-DM-DXXX-XXX 451A-COB-DM-DXXX-XXX 461A-COB-DM-DXXX-XXX 471A-COB-DM-DXXX-XXX G1/4 411A-DOB-DM-DXXX-XXX 421A-DOB-DM-DXXX-XXX 451A-DOB-DM-DXXX-XXX 461A-DOB-DM-DXXX-XXX 471A-DOB-DM-DXXX-XXX DUAL PRESSURE VALVES Port size Pilot air 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre 5/3 Pressure centre G1/8 Internal A-COA-DM-DXXX-XXX A-COA-DM-DXXX-XXX A-COA-DM-DXXX-XXX G1/4 431A-DOA-DM-DXXX-XXX 441A-DOA-DM-DXXX-XXX Not Not 481A-DOA-DM-DXXX-XXX G1/8 External 431A-COB-DM-DXXX-XXX 441A-COB-DM-DXXX-XXX available available 481A-COB-DM-DXXX-XXX G1/4 431A-DOB-DM-DXXX-XXX 441A-DOB-DM-DXXX-XXX 481A-DOB-DM-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection JB JA JC FB DA DF xx 220V~/50HZ 110V~/50HZ 24V~/50HZ 24V=/1,8W 24V=/5,4W 24V=/12,7W Other Options A 45 cm (Flying leads) 1 Non-locking J Connector 2 Locking x Other Options x Other Options KA KD JB JD BA xx Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads Other Options O P T I O N S 411A-COA-DM-DXXX-XXX 431A-COA-DM-DXXX-XXX click for memory spring (replace by 4).

245 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 400 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : 1.4 to 8.5 bar External pilot : vacuum to 8.5 bar 1.4 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 6.2 mm 1000 Nl/min (C v 1.0) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms 50Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms Pilot valve : DM-DXXX-XXX, including mounting screws and seal NPTF threads. DIMENSIONS Ø 3,25 MTG. HOLES 125,0 DOUBLE OPERATOR (45) 96,0 SGLE OPERATOR (45) 18,0 52,0 PILOT W/45 SOLENOID 15, ,8 9,3 18,7 G1/8 PORTS 44,0 39,0 PILOT W/ 45 SOLENOID 32,0 Ø 4,25 MTG.HOLES 62,5 26,0 21,0 10,5 5,0 9,8 51,2 PILOT W/ 45 SOLENOID 18,0 18,0 43,0 PILOT W/ 45 SOLENOID 3 3 5

246 Direct solenoid and solenoid pilot operated valves Series 400 Function Port size Flow (Max) Circuit bar mounting 5/2-5/3 G1/8 - G1/4 800 Nl/min cylinder ports in base OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways. 2. Memory spring available. 3. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow, short and consistent response times. 7. Wiping effect eliminates sticking. 8. Long service life. HOW TO ORDER Reset HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG xxxx-xxx-dm-dxxx-xxx Pilot air 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre 5/3 Pressure centre Internal A-OOA-DM-DXXX-XXX A-OOA-DM-DXXX-XXX A-OOA-DM-DXXX-XXX A-OOA-DM-DXXX-XXX A-OOA-DM-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection JB JA JC FB DA DF 220V~/50HZ 110V~/50HZ 24V~/50HZ 24V=/1,8W 24V=/5,4W 24V=/12,7W xx Other Options HOW TO ORDER CIRCUIT BAR (BOTTOM CYLDER PORTS) ** A 45 cm (Flying leads) 1 Non-locking J Connector 2 Locking x Other Options x Other Options CBM404A-xxxxx-xx KA KD JB JD BA xx Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads Other Options Port size Pilot air Spacing standard 19,5 mm w/o flow regulators w/ flow regulators Spacing 26 mm (Rectangular connector) w/o flow regulators w/ flow regulators G1/8 Internal CBM404A-00AAB-XX CBM404A-00BAB-XX CBM404A-02AAB-XX CBM404A-02BAB-XX G1/4 Internal CBM404A-00AAE-XX CBM404A-00BAE-XX CBM404A-02AAE-XX CBM404A-02BAE-XX ** Other options available. Consult factory. XX = Number of stations (03=3 stations) O P T I O N S 413A-COA-DM-DXXX-XXX click for memory spring (replace by 6).

247 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 400 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Accessories : Options : Compressed air, vacuum, inert gases Internal pilot : 1.4 to 8.5 bar External pilot : vacuum to 8.5 bar 1.4 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 6.2 mm 800 Nl/min (C v 0.8) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms 50Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms Pilot valve : DM-DXXX-XXX, including mounting screws and seal Blanking plate : M Flow regulator : (x2) : N Seal : Mounting screw (x2) : NPTF threads. Isolation of inlet and/or exhaust. Individual external pilot. DIMENSIONS 32,0 125,0 DOUBLE (45) 96,0 SGLE (45) 27, ,0 C L ,5 69,5 100,3 C L , ,5 21,0 15,0 20,5 24,5 38,0 Ø6,5 G3/8 " PORTS ,5 B A 41,0 67,5 82,0 Port size A B G1/8 G1/4 31,5 32,0 19,0 20,0

248 Direct solenoid and solenoid pilot operated valves Series 400 Function Port size Flow (Max) Circuit bar mounting 5/2-5/3 G1/8 - G1/4 800 Nl/min cylinder ports in base OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways. 2. Memory spring available. 3. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow, short and consistent response times. 7. Wiping effect eliminates sticking. 8. Long service life. HOW TO ORDER Reset HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG xxxx-xxx-dm-dxxx-xxx Pilot air 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre 5/3 Pressure centre Internal A-OOA-DM-DXXX-XXX A-OOA-DM-DXXX-XXX A-OOA-DM-DXXX-XXX A-OOA-DM-DXXX-XXX A-OOA-DM-DXXX-XXX Common External 413A-OOD-DM-DXXX-XXX 423A-OOD-DM-DXXX-XXX 453A-OOD-DM-DXXX-XXX 463A-OOD-DM-DXXX-XXX 473A-OOD-DM-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection JB 220V~/50HZ JA 110V~/50HZ JC 24V~/50HZ FB 24V=/1,8W DA 24V=/5,4W DF 24V=/12,7W xx Other Options HOW TO ORDER CIRCUIT BAR ** A 45 cm (Flying leads) 1 Non-locking J Connector 2 Locking x Other Options x Other Options CBM405A-xxxxx-xx KA KD JB JD BA xx Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads Other Options Port size Pilot air Spacing standard 19,5 mm Spacing 26 mm (Rectangular connector) G1/8 Internal CBM405A-00AAB-XX CBM405A-02AAB-XX External comune CBM405A-00BAB-XX CBM405A-02BAB-XX G1/4 Internal CBM405A-00AAE-XX CBM405A-02AAE-XX External comune CBM405A-00BAE-XX CBM405A-02BAE-XX ** Other options available. Consult factory. XX = Number of stations (03=3 stations) O P T I O N S 413A-OOA-DM-DXXX-XXX click for memory spring (replace by 6).

249 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 400 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Accessories : Options : Compressed air, vacuum, inert gases Internal pilot : 1.4 to 8.5 bar External pilot : vacuum to 8.5 bar 1.4 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 6.2 mm 800 Nl/min (C v 0.8) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA Holding : 7.7 VA = 1.8 to 12.7 W 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms 50Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms Pilot valve : DM-DXXX-XXX, including mounting screws and seal Blanking plate : M Seal : Mounting screw (x2) : NPTF threads. Isolation of inlet and/or exhaust. Individual external pilot. DIMENSIONS ,0 25,0 C L 69,5 C L , ,0 125,0 DOUBLE (45) 32,0 96,0 SGLE (45) 114,3 2 40,0 33,5 22,0 52,0 19,0 4 9,5 G3/8" PORTS 46,0 35,0 20,0 G1/8 EXTERNAL PILOT PORT (OPTIONAL) 72,0

250 Direct solenoid and solenoid pilot operated valves Series 400 Function Port size Flow (Max) Circuit bar mounting 5/2-5/3 G1/8 - G1/ Nl/min cylinder ports in valve OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting forces both ways. 2. Memory spring available. 3. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Pilot with balanced poppet, high flow, short and consistent response times. 7. Wiping effect eliminates sticking. 8. Long service life. HOW TO ORDER Reset HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG xxxx-xxx-dm-dxxx-xxx Port size Pilot air 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre 5/3 Pressure centre G1/8 Internal A-COA-DM-DXXX-XXX A-COA-DM-DXXX-XXX A-COA-DM-DXXX-XXX A-COA-DM-DXXX-XXX A-COA-DM-DXXX-XXX G1/4 411A-DOA-DM-DXXX-XXX 421A-DOA-DM-DXXX-XXX 451A-DOA-DM-DXXX-XXX 461A-DOA-DM-DXXX-XXX 471A-DOA-DM-DXXX-XXX G1/8 Common 411A-COD-DM-DXXX-XXX 421A-COD-DM-DXXX-XXX 451A-COD-DM-DXXX-XXX 461A-COD-DM-DXXX-XXX 471A-COD-DM-DXXX-XXX G1/4 External 411A-DOD-DM-DXXX-XXX 421A-DOD-DM-DXXX-XXX 451A-DOD-DM-DXXX-XXX 461A-DOD-DM-DXXX-XXX 471A-DOD-DM-DXXX-XXX SOLENOID OPERATOR D XX X- X XX * XX Voltage X Wire length X Manual operator XX Electrical connection JB JA JC FB DA DF xx 220V~/50HZ 110V~/50HZ 24V~/50HZ 24V=/1,8W 24V=/5,4W 24V=/12,7W Other Options A 45 cm (Flying leads) 1 Non-locking J Connector 2 Locking x Other Options x Other Options KA KD JB JD BA xx Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads Other Options HOW TO ORDER CIRCUIT BAR ** CBM403A-xxxxx-xx Port size Pilot air Spacing standard 19,5 mm w/o flow regulators w/ flow regulators Spacing 26 mm (Rectangular connector) w/o flow regulators w/ flow regulators G3/8 Internal CBM403A-00AAB-XX CBM403A-00BAB-XX CBM403A-02AAB-XX CBM403A-02BAB-XX External comune CBM403A-00CAB-XX CBM403A-00DAB-XX CBM403A-02CAB-XX CBM403A-02DAB-XX ** Other options available. Consult factory. XX = Number of stations (03=3 stations) O P T I O N S 411A-COA-DM-DXXX-XXX click for memory spring (replace by 6).

251 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 400 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Accessories : Options : Compressed air, vacuum, inert gases Internal pilot : 1.4 to 8.5 bar External pilot : vacuum to 8.5 bar 1.4 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 6.2 mm 1000 Nl/min (C v 1.0) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 10.9 VA = 1.8 to 12.7 W Holding : 7.7 VA 24 V=/5.4 W Energize : 7.3 m De-energize : 5.3ms 50Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms Pilot valve : DM-DXXX-XXX, including mounting screws and seal Blanking plate : M Flow regulator (x2) : N Seal : (x2), (x1). Mounting screw (x2) : NPTF threads. Isolation of inlet and/or exhaust. Individual external pilot. DIMENSIONS 32,0 125,0 DOUBLE (45) 96,0 SGLE (45) 27, ,0 C L ,5 69,5 100,3 C L , ,5 21,0 8,0 15,0 20,5 24,5 38,0 Ø6,5 G 3/8" 14,5 67,5 41,0 32,0 G1/8 EXTERNAL PILOT PORT (OPTIONAL) 82,0

252 O p t i o n s OPTIONS Codification table for voltages / Wire length / Manual operator / Electrical connection VALVE CODE D M - D XX X - X XX OPTIONS AVAILABLE FOR - pilot operated valves 400 & 52 Series

253 OPTIONS Back 1. VOLTAGE - D XX X - X XX VOLTAGE DA 24 V=/5,4 W DB 12 V=/5,4 W DC 12 V=/7,5 W DD 24 V=/7,3 W DE 12 V=/12,7 W DF 24 V=/12,7 W DK 110 V=/4,7 W DJ 28 V=/5,2 W DL 64 V=/6 W DM 36 V=/5,3 W DN 6 V=/6 W DR 90 V=/6,6 W DS 110 V=/7,3 W DT 75 V=/5,6 W DP 48 V=/5,8 W FA 12 V=/1,8 W FB 24 V=/1,8 W FE 12 V=/2,4 W FF 24 V=/2,4 W JA 120V~/60 Hz, 110V~/50 Hz (2,9 W) JB 240 V~/60 Hz, 220V~/50 Hz (2,9 W) JC 24 V~/60 Hz, 24V~/50 Hz (3,7 W) JD 100 V~/60 Hz, 100V~/50 Hz, 110V~/60 Hz (3,9 W) 2. WIRE LENGTH - D XX X - X XX WIRE LENGTH A 45 cm - 18 B 60 cm - 24 C 90 cm - 36 D 120 cm - 48 E 180 cm - 72 F 240 cm - 96 J For external plug-in connector

254 O p t i o n s OPTIONS Back 3. MANUAL OPERATOR - D XX X - X XX MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 4. ELECTRICAL CONNECTION - D XX X - X XX ELECTRICAL CONNECTION BA Flying leads BK BA with protection diode BL BA with protection varistor CA 1/2" NPS conduit JB Rectangular connector JD Rectangular connector with light JM Rectangular connector, male only KA Square connector KB Square connector with protection diode KC Square connector with protection varistor KD Square connector with light KE Square connector with light and protection diode KF Square connector with light and protection varistor KJ Square connector (male only) KK Square connector with protection diode (male only) KL Square connector with protection varistor (male only) TA Dual tabs TB TA with protection diode TD TA with light TE TA with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode

255 Direct solenoid and solenoid pilot operated valves Series 800 Individual mounting inline Circuit bar mounting cylinder ports in valve with shut-off valve

256 Direct solenoid and solenoid pilot operated valves Series 800 Function Port size Flow (Max) Individual mounting 5/2-5/3 G1/ Nl/min inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset xxxx-pm-xxyzz-xxx Port size Pilot air 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre 5/3 Pressure centre A 3 2 B A 3 2 B B 2 3 A B 2 3 A B 2 3 A G1/4 Internal 811C-PM-XXYZZ C-PM-XXYZZ C-PM-XXYZZ C-PM-XXYZZ C-PM-XXYZZ-855 External 812C-PM-XXYZZ C-PM-XXYZZ C-PM-XXYZZ C-PM-XXYZZ C-PM-XXYZZ-815 SOLENOID OPERATOR XX Y ZZ * Voltage Manual operator Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options xx Other Options

257 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 800 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.4 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 14 bar Single operator and 3 positions : 1.4 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/4" : 1400 Nl/min (C v 1.4) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize : 8 ms De-energize : 10ms 50Hz/6 W Energize : 5-11 ms De-energize : 9-16 ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Mounting screw pilot to main valve : NPTF threads. NAMUR interface. Explosion-proof model. DIMENSIONS 47,6 Ø6,7 ~31,0 56,0 50,8 OPER. "B" 2 3 OPER. "A" 35,1 57, ,5 G1/8 EXT. PILOT (OPTION) 183,2 136, ,0 2 3 G1/4 (5 ) 25,4

258 Direct solenoid and solenoid pilot operated valves Series 800 Function Port size Flow (Max) Circuit bar mounting 5/2-5/3 G1/ Nl/min cylinder ports in valve OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset xxxx-pm-xxyzz-xxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Port size 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre 5/3 Pressure centre A 3 2 B A 3 2 B B 2 3 A B 2 3 A B 2 3 A G1/4 811C-PM-XXYZZ C-PM-XXYZZ C-PM-XXYZZ C-PM-XXYZZ C-PM-XXYZZ-875 SOLENOID OPERATOR XX Y ZZ * Voltage Manual operator Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz 59 24V=/2,5W y Other Options BA zz Flying leads (45 cm) Other Options 87 24V=/17,1W 61 24V=/8,5W xx Other Options HOW TO ORDER CIRCUIT BAR** EBM800A-xxxx-xx Port size (Spacing 31 mm) Standard circuit bar Circuit bar with flow regulators (2 per station) G3/8 EBM800A-001B-XX EBM800A-002B-XX * * Other options available. Consult factory. XX = Number of stations (03=3 stations) Note : click for valves mounted on base at the factory (add - 9 to the model number).

259 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 800 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.4 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 14 bar Single operator and 3 positions : 1.4 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/4" : 1300 Nl/min (C v 1.3) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize :8 ms De-energize : 10ms 50Hz/6 W Energize : 5-11 ms De-energize : 9-16 ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Mounting screw pilot to main valve : Blanking plate : M NPTF threads. Isolation of inlet and/or exhaust. Explosion-proof model. DIMENSIONS 183,2 136,0 91,5 56,0 89,2 18,5 EXH EXH 15,5 7,0 EX EX ,0 12, EX EX 15,0 Ø 6,7 2 MTG HOLES 12,7 84,0 12,0 42,0 72,0 FLOW REGULATOR G3/8 7,0 31,0 31,5

260 Direct solenoid and solenoid pilot operated valves Series 800 Function Port size Flow (Max) Circuit bar mounting 5/2-5/3 G1/ Nl/min with shut-off valve OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset xxxx-pm-xxyzz-xxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Port size 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre 5/3 Pressure centre A 3 2 B A 3 2 B B 2 3 A B 2 3 A B 2 3 A G1/4 811C-PM-XXYZZ C-PM-XXYZZ C-PM-XXYZZ C-PM-XXYZZ C-PM-XXYZZ-875 SOLENOID OPERATOR XX Y ZZ * Voltage Manual operator Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz 59 24V=/2,5W y Other Options BA zz Flying leads (45 cm) Other Options 87 24V=/17,1W 61 24V=/8,5W xx Other Options HOW TO ORDER CIRCUIT BAR** EBI800A-xxxx-xx Port size (Spacing 31 mm) w/o inlet shut-off valve w/ inlet shut-off valve G3/8" EBI800A-001B-XX EBI800A-002B-XX * * Other options available. Consult factory. XX = Number of stations (03=3 stations) Note : click for valves mounted on base at the factory (add - 9 to the model number).

261 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 800 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Options : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.4 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 14 bar Single operator and 3 positions : 1.4 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/4" : 1300 Nl/min (C v 1.3) 50 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize : 8 ms De-energize : 10ms 50Hz/6 W Energize : 5-11 ms De-energize : 9-16 ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Mounting screw pilot to main valve : Blanking plate : M Shut-off valve : M NPTF threads. Isolation of inlet. Explosion-proof model. DIMENSIONS 183,2 91,6 56,0 19,0 K C O L 3 2 K C O L 102,2 L K L O C O C O K L K C L K L O C O K C O L K C 13,0 SHOWN OPEN POSITION G3/8 Ø 4 MTG. HOLES 9,5 19,0 26,0 13,0 19,0 SHOWN CLOSED POSITION EXH 40,0 111,0 71,0

262 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

263 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

264 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

265 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

266 Direct solenoid and solenoid pilot operated valves Series ISO 1 Individual mounting sub-base Manifold mounting sub-base

267 Direct solenoid and solenoid pilot operated valves Series ISO 1 Function Port size Flow (Max) Individual mounting & Manifold mounting 5/2-5/3 G1/4 - G3/ Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset MV-A1C-xxxx-PM-xxyzz SGLE PRESSURE VALVES Pilot air 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre Internal MV-A1C-A111-PM-XXYZZ MV-A1C-A211-PM-XXYZZ MV-A1C-A312-PM-XXYZZ MV-A1C-A311-PM-XXYZZ External MV-A1C-A121-PM-XXYZZ MV-A1C-A221-PM-XXYZZ MV-A1C-A322-PM-XXYZZ MV-A1C-A321-PM-XXYZZ DUAL PRESSURE VALVES Pilot air 5/2 Single operator 5/2 Double operator 5/3 Pressure centre Internal port 3 MV-A1C-A131-PM-XXYZZ MV-A1C-A231-PM-XXYZZ MV-A1C-A331-PM-XXYZZ Internal port 5 MV-A1C-A135-PM-XXYZZ MV-A1C-A232-PM-XXYZZ MV-A1C-A332-PM-XXYZZ External MV-A1C-A141-PM-XXYZZ MV-A1C-A241-PM-XXYZZ MV-A1C-A341-PM-XXYZZ SOLENOID OPERATOR XX Y ZZ * Voltage Manual operator Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options Note : ISO valves are delivered w/o base. xx Other Options O P T I O N S MV-A1C-A111-PM-XXYZZ click for CNOMO pilot (replace by CM).

268 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 1 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 9-11 mm G 1/4" - G 3/8" : 1600 Nl/min (C v 1.6) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V =/8.5 W Energize :10ms De-energize : 11ms 50Hz/6 W Energize : 7-13 ms De-energize :10-17 ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : DIMENSIONS A B 92,4 A B 92,4 C L 96,1 ISO 1 Manifold mounting TYPE JA & JC JB & JD A 271,6 294,6 G1/8 EXTERNAL PILOT B 195,8 207,3 100, ,0 25,0 25,0 50,0 85,0 14,0 22,0 26,0 G1/8 EXTERNAL PILOT G1/8 OPTIONAL PILOT EXH. 16, ,0 26,0 121,0 32,5 40,0 113,0 G1/8 OPTIONAL PILOT EXHAUST 3,0 13,0 68,0 13,0 Ø 6,5 2 MTG HOLES 22,0 21,0 26,0 Ø 6,3 2 MTG HOLES ISO 1 Individual mounting TYPE JA & JC JB & JD A 271,6 294,6 B 185,8 197,3 50,0 12,0 11, ,0 85,0 100,0 9,0 14,0 62,0 OPTIONAL BOTTOM PORTS 12,75 25,5 OPTIONAL BOTTOM PORTS , ,0 121,0 5 6,0 18,0 24,75 51,0 ± 0,2

269 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

270 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

271 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

272 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

273 Direct solenoid and solenoid pilot operated valves Series ISO 2 Individual mounting sub-base Manifold mounting sub-base

274 Direct solenoid and solenoid pilot operated valves Series ISO 2 Function Port size Flow (Max) Individual mounting & Manifold mounting 5/2-5/3 G3/8 - G1/ Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset MV-A2B-xxxx-PM-xxyzz SGLE PRESSURE VALVES Pilot air 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre Internal MV-A2B-A111-PM-XXYZZ MV-A2B-A211-PM-XXYZZ MV-A2B-A312-PM-XXYZZ MV-A2B-A311-PM-XXYZZ External MV-A2B-A121-PM-XXYZZ MV-A2B-A221-PM-XXYZZ MV-A2B-A322-PM-XXYZZ MV-A2B-A321-PM-XXYZZ DUAL PRESSURE VALVES Pilot air 5/2 Single operator 5/2 Double operator 5/3 Pressure centre Internal port 3 MV-A2B-A131-PM-XXYZZ MV-A2B-A231-PM-XXYZZ MV-A2B-A331-PM-XXYZZ Internal port 5 MV-A2B-A135-PM-XXYZZ MV-A2B-A232-PM-XXYZZ MV-A2B-A332-PM-XXYZZ External MV-A2B-A141-PM-XXYZZ MV-A2B-A241-PM-XXYZZ MV-A2B-A341-PM-XXYZZ SOLENOID OPERATOR XX Y ZZ * Voltage Manual operator Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W zz Other Options Note : ISO valves are delivered w/o base. xx Other Options O P T I O N S MV-A2B-A111-PM-XXYZZ click for CNOMO pilot (replace by CM).

275 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 2 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 15 mm G 3/8" - G 1/2" : 3000 Nl/min (C v 3.0) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 w Energize :10ms De-energize : 15ms 50Hz/6 W Energize : 6-15 ms De-energize :10-17 ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : DIMENSIONS A B 102,4 A B 102,4 ISO 2 Manifold mounting TYPE JA & JC JB & JD A 291,6 314,6 ISO 2 Individual mounting B 214,8 226,3 G1/8 EXTERNAL PILOT 3,8 16,0 62,0 12, ,0 60,0 3 88,0 36, ,0 23,0 32,0 G1/8 OPTIONAL PILOT EXHAUST 5 10,0 119,7 131,5 75,0 16,0 54,0 20,0 G1/8 EXTERNAL PILOT 7,5 DIA. THRU 2 MTG. HOLES 14,0 14,5 32,0 30, ,0 34,0 G1/2-3 PORTS EACH SIDE 26,0 70, ,0 34, ,0 42,0 50,5 7,0 9,0 135,6 147,7 1/8 OPTIONAL PILOT EXHAUST 6,5 DIA. 2 MTG. HOLES 30,5 52,0 64,0 ± 0,2 TYPE JA & JC A 291,6 B 212,3 7,0 62,0 98,0 112,0 OPTIONAL BOTTOM PORTS OPTIONAL BOTTOM PORTS 112,0 139,0 JB & JD 314,6 223,8

276 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

277 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

278 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

279 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

280 Direct solenoid and solenoid pilot operated valves Series ISO 3 Individual mounting sub-base Manifold mounting sub-base

281 Direct solenoid and solenoid pilot operated valves Series ISO 3 Function Port size Flow (Max) Individual mounting & Manifold mounting 5/2-5/3 G1/2 - G3/ Nl/min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return force thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. HOW TO ORDER Reset MV-A3B-xxxx-PM-xxyzz SGLE PRESSURE VALVES Pilot air 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre Internal MV-A3B-A111-PM-XXYZZ MV-A3B-A211-PM-XXYZZ MV-A3B-A312-PM-XXYZZ MV-A3B-A311-PM-XXYZZ External MV-A3B-A121-PM-XXYZZ MV-A3B-A221-PM-XXYZZ MV-A3B-A322-PM-XXYZZ MV-A3B-A321-PM-XXYZZ DUAL PRESSURE VALVES Pilot air 5/2 Single operator 5/2 Double operator 5/3 Pressure centre Internal port 3 MV-A3B-A131-PM-XXYZZ MV-A3B-A231-PM-XXYZZ MV-A3B-A331-PM-XXYZZ Internal port 5 MV-A3B-A135-PM-XXYZZ MV-A3B-A232-PM-XXYZZ MV-A3B-A332-PM-XXYZZ External MV-A3B-A141-PM-XXYZZ MV-A3B-A241-PM-XXYZZ MV-A3B-A341-PM-XXYZZ SOLENOID OPERATOR XX Y ZZ * Voltage Manual operator Electrical connection V~/50Hz 1 Non-locking JB Rectangular connector V~/50Hz 2 Locking JD Rectangular connector with light 22 24V~/50Hz y Other Options JA Square connector 59 24V=/2,5W JC Square connector with light 87 24V=/17,1W BA Flying leads (45 cm) 61 24V=/8,5W xx Other Options Note : ISO valves are delivered w/o base. zz Other Options O P T I O N S MV-A3B-A111-PM-XXYZZ click for CNOMO pilot (replace by CM).

282 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 3 T E C H N I C A L D A T A Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Spare parts : Compressed air, vacuum, inert gases Internal pilot : single operator and 3 positions : 1.8 to 10 bar double operator : 0.7 to 10 bar External pilot : vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 24 mm G 1/2" - G 3/4" : 6300 Nl/min (C v 6.3) 100 cm 3 /min Epoxy encapsulated - class A wires - 100% ED (specify mod 0449) -15% to +10% of nominal voltage IP 65 Inrush : 14.8 VA = 1 to 17.1 W Holding : 10.9 VA 24 V=/8.5 W Energize : 18ms De-energize : 20 ms 50Hz/6 W Energize : 15-25ms De-energize : ms Solenoid operator (power 4 W) : D1-XXYZZ1, including mounting screws and seal Pilot valve : PME-XXYZZ, including seal Pressure seal between valve and base : Mounting screw valve to base (x4) : Check valve : (+M-00011). DIMENSIONS A B 119,9 136,2 124, ,0 33,0 27, ,5 55,0 22,0 45,0 45,0 20,5 20,5 ISO 3 Individual mounting G1/8 EXTERNAL PILOT 49,0 49,0 168,0 15,0 140,0 35,0 17,5 70,0 Ø 8,3 MTG. HOLES TYPE A B 32, ,5 JA & JC JB & JD 326,6 349,6 247,3 258,8 64,0 21,0 15, ,0 49,0 78,0 156,0 79,0 OPTIONAL BOTTOM PORTS

283 O p t i o n s OPTIONS Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 100 Series - pilot valves "CNOMO" - valves type 200 Series - Pilot operated valves with pilots type 100 Series Series : ISO 1 - ISO 2 - ISO 3. - pilot operated valves with pilots type 200 Series Series : Pilot operated valves with pilots "CNOMO" Series : ISO1 - ISO2 - ISO3

284 OPTIONS Back 1. VOLTAGE (type 100 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz 20 6 V~/60 Hz V~/50 Hz - 12 V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz, 440 V~/50 Hz -440 V~/60 Hz, 480 V~/60 Hz-CLSF V~/60 Hz V~/50 Hz V~/50 Hz V~/50 Hz V~/60 Hz B1 24 V~/50 Hz V=/6 W V=/4 W V=/4 W V=/6 W V=/2,5 W V=/2,5 W V=/8,5 W V=/8,5 W 64 6 V=/6 W V=/7 W V=/5,8 W V=/7,5 W V=/6,4 W V=/8,7 W V=/11,2 W CLSF V=/8,8 W CLSF V=/6,9 W CLSF V=/10,9 W CLSF V=/17,1 W CLSF V=/17,4 W CLSF V=/18,8 W CLSF V=/8,2 W 91 6 V=/10,6 W CLSF V=/6,5 W 94 3 V=/7 W V=/6,4 W A1 24 V=/1 W A2 12 V=/1 W A3 9 V=/1 W MOD. DD01 : Protection diode (DC) MOD. MOV1 : Protection varistor (AC) MOD. DD01 : max. 8,5 W MOD. MOV1 : max. 8,5 W 1. VOLTAGE (type 200 Series) - XX Y ZZ VOLTAGE V~/60 Hz V~/50 Hz - 24 V= V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz 20 6 V~/60 Hz V~/60 Hz V~/60 Hz - 24 V~/50 Hz V~/60 Hz - 32 V~/50 Hz V~/60 Hz - 42 V~/50 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/60 Hz V~/50 Hz V~/50 Hz V=/6 W V=/4,5 W V=/2,5 W V=/1 W V=/6 W V=/2,5 W V=/2,5 W V=/9,5 W V=/8,5 W 64 6 V=/8,5 W V=/10 W V=/11,5 W V=/10,5 W V=/12,3 W V=/9,2 W 71 8 V=/8,2 W V=/12 W V=/10 W V=/11,3 W V=/11,3 W V=/9 W V=/10 W V=/1,6 W V=/24 W CLSF V=/10,6 W CLSF V=/11,1 W V=/8,1 W V=/10 W V=/11 W V=/24 W CLSF

285 O p t i o n s OPTIONS Back 2. MANUAL OPERATOR (Common options for 100 & 200 Series) - XX Y ZZ MANUAL OPERATOR 0 No operator 1 Non-locking recessed 2 Locking recessed 3 Non-locking extended 4 Locking extended 3. ELECTRICAL CONNECTION (type 100 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO2, ISO3) JF Rectangular connector on top (ISO1, ISO2, ISO3) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit MB Electrical common conduit NA CA with ground wire NC CC with ground wire RA 3/8" NPS conduit AD Wiring box 20 mm AH Wiring box PG 13,5 with ground wire CD 20 mm conduit CG PG 11 conduit HH Wiring box PG 13,5 with ground wire ND 20 mm conduit with ground wire 3. ELECTRICAL CONNECTION (type 200 Series) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with 1/2" NPS conduit BA Flying leads CA 1/2" NPS conduit CC 1/2" NPS conduit EA Explosion proof (200 Series) EA Explosion proof (57, 58 & 59 Series) EE Explosion proof (CENELEC) EN Explosion proof with ground wire FA Military type 2 P GA Military type 3 P HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire AD Wiring box 20 mm AK PG 16 wiring box CD 20 mm conduit CK PG 16 conduit HD 20 mm wiring box with ground wire HK PG16 wiring box with ground wire ND 20 mm conduit with ground wire NK PG16 wiring box with ground wire NG PG11 conduit with ground wire HD 20 mm wiring box with ground wire * Not to be used with 100, 800 and 900 Series manifold mounting

286 OPTIONS Back 4. WIRE LENGTH (Common options for 100 & 200 Series) - XX Y ZZ (-VV) WIRE LENGTH AA 45 cm - 18 AB 60 cm - 24 AD 90 cm - 36 AE 120 cm - 48 AF 180 cm - 72 AG 15 cm - 6 AR 30 cm - 12 AU 305 cm BA 152 cm - 60 BB 366 cm Series 6000 : wire length, delivered with the base MOD L cm - 24 MOD L cm - 36 MOD L cm - 48 MOD L cm - 60 MOD L cm - 72 MOD L cm - 120

287 R e m o t e a i r v a l v e s Series 1100 Individual mounting Inline Manifold mounting sub-base

288 R e m o t e a i r v a l v e s Series 1100 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G1/8" - G1/4" 180 Nl/Min Inline OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. Powerful return spring. 4. Maximum shifting forces. HOW TO ORDER Reset xxxxx-114 Port size Universal valve NC only valve 2 2 Air pilot port : G 1/8. G1/8" G1/4" A A A A-114

289 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 1100 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar 1.4 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm 180 Nl/min (C v 0.18) 50 cm 3 /min Options : NPTF threads. DIMENSIONS 24,6 Ø 5 mm #2 #1 17,8 33,8 22,0 G #3 C D 4, H 24,9 B 21,2 A Ø 4,4 22,2 33,0 Port size A B C D G H G1/8" 28,4 12,7 14,0 8,0 60,1 23,2 G1/4" 29,8 13,3 12,7 9,9 60,9 24,1

290 R e m o t e a i r v a l v e s Series 1100 Function Port size Flow (Max) Manifold mounting 3/2 NO-NC, 2/2 NO-NC G1/8" 140 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced poppet, immune to variations of pressure. 2. Short stroke with high flow. 3. Powerful return spring. 4. Maximum shifting forces. HOW TO ORDER Reset xxxxx-114 Port size Universal valve NC only valve CYL CYL Valve less base Sub-base G1/8" Air pilot port : G 1/8". End plate kit (G 1/4" ports) : A P. EXH 1130A A-114 EXH 1170A A-114

291 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 1100 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar 1.4 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm G 1/8" : 140 Nl/min (C v 0.14) 50 cm 3 /min Spare parts : Options : Function plate : A Pressure seal between bases : Tie-rod (x2) : NPTF threads. DIMENSIONS G1/8 CYL. PORT 16,8 30,1 17,6 CYL 59,5 14,2 25,4 ± 0,1 EXH 12,7 17,8 9,7 ± 0,2 2,3 4,8 OPTIONAL G1/8 BOTTOM PORTS 25,4 63,5 66,9 31,5 CYL 15,7 32,7 46,6 G1/4 LET & EXHAUST PORTS MT G SLOT Ø 6,6 MAX. EXH 5,7

292 R e m o t e a i r v a l v e s Series 55 Individual mounting Inline

293 R e m o t e a i r v a l v e s Series 55 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G1/4" - G3/8" 2200 Nl/Min Inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset 55B-xx-xx Port size Air spring NC valve NO valve CYL CYL EXH EXH G1/4" Internal 55B-13-RA 55B-23-RA G3/8" 55B-14-RA 55B-24-RA G1/4" External 55B-13-RE 55B-23-RE G3/8" 55B-14-RE 55B-24-RE Air pilot port : G 1/8.

294 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 55 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar 1.8 to 10 bar main valve pressure Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 8 mm G1/4 : 1400 Nl/min (C v 1.4) - G 3/8" : 1600 Nl/min (C v 1.6) 50 cm 3 /min Spare parts : Options : Remote air operator : R Check valve : NPTF threads. DIMENSIONS G1/8 PILOT PORT 19,5 LET & CYL. PORTS EXH. PORT.G3/8 2 MTG. HOLES Ø 6,6 63,5 71, ,0 43,7 26,0 23,5 44,5 29,5 56,0 46,0

295 R e m o t e a i r v a l v e s Series 56 Individual mounting Inline

296 R e m o t e a i r v a l v e s Series 56 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G3/8" - G1/2" - G3/4" 5700 Nl/Min Inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset 56C-xx-xx Port size Air spring NC valve NO valve CYL CYL EXH EXH G3/8" 56C-55-RA 56C-85-RA G1/2" Internal 56C-56-RA 56C-86-RA G3/4" 56C-58-RA 56C-88-RA G3/8" 56C-55-RE 56C-85-RE G1/2" External 56C-56-RE 56C-86-RE G3/4" 56C-58-RE 56C-88-RE Air pilot port : G 1/8.

297 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 56 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar 1.8 to 10 bar main valve pressure Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 16 mm G 3/8" : 4400 Nl/min (C v 4.4) - G 1/2" : 5000 Nl/min (C v 5.0) - G 3/4" : 5400 Nl/min (C v 5.4) 70 cm 3 /min Spare parts : Options : Remote air operator : R Check valve : NPTF threads. DIMENSIONS 37,5 G1/8 REMOTE PILOT Ø 8,6 MOUNTG HOLES PILOT EXHAUST OR REMOTE PILOT 3 102,5 80,0 64, ,6 26,3 35,5 28,6 39,0 57,2 73,5 EXHAUST PORT G3/4 76,0 38,0

298 R e m o t e a i r v a l v e s Series 57 Individual mounting Inline

299 R e m o t e a i r v a l v e s Series 57 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G1/2" - G3/4" - G1" Nl/Min Inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset 57C-xx-xx Port size Air spring NC valve NO valve CYL CYL EXH EXH G1/2" 57C-54-RA 57C-84-RA G3/4" Internal 57C-55-RA 57C-85-RA G1" 57C-56-RA 57C-86-RA G1/2" 57C-54-RE 57C-84-RE G3/4" External 57C-55-RE 57C-85-RE G1" 57C-56-RE 57C-86-RE Air pilot port : G 1/8.

300 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 57 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar 1.8 to 10 bar main valve pressure Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 27 mm G 1/2" : 9000 Nl/min (C v 9.0) - G 3/4" : Nl/min (C v 12.7) - G 1" : Nl/min (C v 15.9) 100 cm 3 /min Spare parts : Options : Remote air operator : R Check valve : NPTF threads. DIMENSIONS Ø 8,6 MT G HOLES G1/8 REMOTE PILOT 33,0 EXHAUST PORT 45,7 LET & CYL. PORTS CYL EXH 143,9 90,4 90,4 61,7 39,7 82,6 54,1 112,3 96,8 42,7

301 R e m o t e a i r v a l v e s Series 58 Individual mounting Inline

302 R e m o t e a i r v a l v e s Series 58 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G1" - G1 1/4" - G1 1/2" Nl/Min Inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset 58C-xx-xx Port size Air spring NC valve NO valve CYL CYL EXH EXH G1" 58C-54-RA 58C-84-RA G1 1/4" Internal 58C-55-RA 58C-85-RA G1 1/2" 58C-56-RA 58C-86-RA G1" 58C-54-RE 58C-84-RE G1 1/4" External 58C-55-RE 58C-85-RE G1 1/2" 58C-56-RE 58C-86-RE Air pilot port : G 1/8.

303 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 58 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar 1.8 to 10 bar main valve pressure Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 38 mm G 1" : Nl/min (C v 18.7) - G 1 1/4" : Nl/min (C v 23.0) - G 1 1/2" : Nl/min (C v 24.9) 100 cm 3 /min Spare parts : Options : Remote air operator : R Check valve : NPTF threads. DIMENSIONS Ø 13,5 MT G HOLES G1/8 REMOTE PILOT 33,0 EXHAUST PORT 50,8 LET & CYL. PORTS CYL EXH 178,7 114,3 124,7 84,1 57,7 118,4 70,3 143,7 116,1 47,8

304 R e m o t e a i r v a l v e s Series 59 Individual mounting Inline

305 R e m o t e a i r v a l v e s Series 59 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G2 - G2 1/2" Nl/Min Inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset 59B-xx-xx Port size Air spring NC valve CYL G2 G2 1/2" G2 G2 1/2" Air pilot port : G 1/8. Internal External EXH 59B-55-RA 59B-56-RA 59B-55-RE 59B-56-RE

306 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 59 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar 1.8 to 10 bar main valve pressure Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 53 mm G 2" : Nl/min (C v 55.0) - G 2 1/2" : Nl/min (C v 60.0) 150 cm 3 /min Spare parts : Options : Remote air operator : R Check valve : NPTF threads. DIMENSIONS Ø 13,5 MT G HOLES G1/8 REMOTE PILOT 33,0 EXHAUST PORT 84,8 LET & CYL. PORTS CYL EXH 240,3 155,4 174,5 111,0 77,8 155,6 100,3 200,7 157,5 67,3

307 R e m o t e a i r v a l v e s Series 700 Individual mounting Inline Manifold mounting stacking

308 R e m o t e a i r v a l v e s Series 700 Function Port size Flow (Max) Individual mounting 4/2 G1/8" - G1/4" 700 Nl/Min Inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxx-xx-xx Port size Single operator Double operator A A B B A A B B G1/8" G1/4" EX 711C-13-RA 711C-14-RA EX 721C-13-RA 721C-14-RA HOW TO ORDER VALVE WITH FLOW REGULATORS Port size Single operator Double operator A A B B A A B B Air pilot port : G 1/8. G1/8" G1/4" EX 712C-13-RA 712C-14-RA EX 722C-13-RA 722C-14-RA

309 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 700 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator : 1.4 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 5.6 mm G 1/8" : 600 Nl/min (C v 0.6) - G 1/4" : 700 Nl/min (C v 0.7) 50 cm 3 /min Spare parts : Options : Remote air operator : R Valve cover plate with integral flow controls : N NPTF threads. DIMENSIONS 36,8 2 MTG. HOLES Ø 6,5 19,0 10,5 59,0 41,5 EX PILOT 5,5 41,0 30,0 7,3 16,8 EX B A 7,3 9,5 A 75,5 G1/8 REMOTE PILOT PORT 19,0 8,5 89,5 PORT SIZE G1/8" G1/4" A 21,0 24,0

310 R e m o t e a i r v a l v e s Series 700 Function Port size Flow (Max) Manifold mounting 4/2 G1/8" - G1/4" 800 Nl/Min stacking OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxx-xx-xx Port size Single operator Double operator A A B B A A B B G1/8" G1/4" EX 713C-13-RA 713C-14-RA EX 723C-13-RA 723C-14-RA HOW TO ORDER VALVE WITH FLOW REGULATORS Port size Single operator Double operator A A B B A A B B G1/8" G1/4" End plate kit (Port size G1/4") : M P, internal pilot. M P, External pilot. Air pilot port : G 1/8. EX 714C-13-RA 714C-14-RA EX 724C-13-RA 724C-14-RA

311 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 700 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator : 1.4 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 5.6 mm G 1/8" : 700 Nl/min (C v 0.7) - G 1/4" : 800 Nl/min (C v 0.8) 50 cm 3 /min Spare parts : Options : Remote air operator : R Valve cover plate with integral flow controls : N Pressure seal between valves : Tie-rod (x2) : NPTF threads. DIMENSIONS 36,8 Ø 3,3 76,3 58,9 42,5 19,5 8,0 G1/4 LET EX 44,8 75,5 G3/8 EXHAUST SGLE REMOTE 27,0 17,5 30,0 12,5 B B A A PILOT PILOT 22,0 5,5 G1/8 REMOTE PILOT PORT 89,5 DOUBLE REMOTE 43,0

312 R e m o t e a i r v a l v e s Series 900 Individual mounting Inline Manifold mounting stacking

313 R e m o t e a i r v a l v e s Series 900 Function Port size Flow (Max) Individual mounting 4/2 G1/8" - G1/4" 1200 Nl/Min Inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxx-ra Port size Single operator Double operator A A B B A A B B Air pilot port : G 1/8. G1/8" G1/4" EX 915B-RA 916B-RA EX 925B-RA 926B-RA

314 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 900 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/8" : 800 Nl/min (C v 0.8) - G 1/4" : 1200 Nl/min (C v 1.2) 50 cm 3 /min Spare parts : Options : Remote air operator (single operator) : R P. Remote air operator ( double operator) : R P. NPTF threads. DIMENSIONS G1/8 REMOTE PILOT CYL B CYL A 43,4 21,0 EXH 15,0 26,0 7,5 EXH 7,5 45,0 15,0

315 R e m o t e a i r v a l v e s Series 900 Function Port size Flow (Max) Manifold mounting 4/2 G1/8" - G1/4" - G3/8" 1200 Nl/Min stacking OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxx-ra Port size Single operator Double operator A A B B A A B B G1/8" G1/4" G3/8" Air pilot port : G 1/8. EX 917B-RA 918B-RA 919B-RA Mod 005 EX 927B-RA 928B-RA 929B-RA Mod 005 Manifold fastening kit (G3/8") : M P

316 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 900 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/8" : 800 Nl/min (C v 0.8) - G 1/4" - G3/8 : 1200 Nl/min (C v 1.2) 50 cm 3 /min Spare parts : Options : Remote air operator (single operator) : R P. Remote air operator (double operator) : R P. Pressure seal between valves : Tie-rod (x2) : NPTF threads. DIMENSIONS 7,5 80,0 7,5 57,9 45,0 15,0 40,0 34,0 EXH 25,0 34,0 29,0 EXH 11,1 ± 0,2 17,0 37,0 11,5 CYL B CYL A G3/8 LET & EXH 12,9 CYL B CYL A 25,4 ± 0,1 Ø 6,4 MTG. SLOT EXH 30,0 28,0 10,0 ± 0,4 15,5

317 R e m o t e a i r v a l v e s Series 82 Individual mounting sub-base Manifold mounting sub-base

318 R e m o t e a i r v a l v e s Series 82 Function Port size Flow (Max) Individual mounting 4/2-4/3 G1/8" - G1/4" - G3/8" 1350 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset 82A-xx-xxx-RA Port size 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A EX EX EX EX EX Valve less base 82A-AB-000-RA 82A-BB-000-RA 82A-EB-000-RA 82A-FB-000-RA 82A-GB-000-RA Sub-base G1/8" 82A-AB-DAA-RA 82A-BB-DAD-RA 82A-EB-DAD-RA 82A-FB-DAD-RA 82A-GB-DAD-RA Sub-base G1/4" 82A-AB-EAA-RA 82A-BB-EAD-RA 82A-EB-EAD-RA 82A-FB-EAD-RA 82A-GB-EAD-RA Sub-base G3/8" 82A-AB-FAA-RA 82A-BB-FAD-RA 82A-EB-FAD-RA 82A-FB-FAD-RA 82A-GB-FAD-RA O P T I O N S 82A-AB-000-RA - click for dual pressure valves (replace A by C, B by D, E by M, F by L, G by H).

319 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 82 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/8" : 900 Nl/min (C v 0.9) - G 1/4" : 1300 Nl/min (C v 1.3) - G 3/8" : 1350 Nl/min (C v 1.35) 100 cm 3 /min Spare parts : Options : Remote air operator : NPTF threads. DIMENSIONS 80,0 G1/8 EXTERNAL PILOT PORT P-B P-A 34,0 32,0 EXH 17,0 12,0 11,3 27,5 22,0 15,0 81,0 55,0 17,0 CYL B CYL A 30,5 EX PA P-B C L C L B A C L 12,5 43,0 21,5 Ø 5,3 5,0 27,5 26,0 OPTIONAL BOTTOM PORTS 19,0 8,5

320 R e m o t e a i r v a l v e s Series 82 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G1/4" - G3/8" 1350 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset 82A-xx-xxx-TM-RA14 Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A EX EX EX EX EX Valve Internal 82A-AB-000-TM-RA14 82A-BB-000-TM-RA14 82A-EB-000-TM-RA14 82A-FB-000-TM-RA14 82A-GB-000-TM-RA14 less base only Sub-base Internal 82A-AB-EKA-TM-RA14 82A-BB-EKA-TM-RA14 82A-EB-EKA-TM-RA14 82A-FB-EKA-TM-RA14 82A-GB-EKA-TM-RA14 G1/4" External 82A-AB-EKD-TM-RA14 82A-BB-EKD-TM-RA14 82A-EB-EKD-TM-RA14 82A-FB-EKD-TM-RA14 82A-GB-EKD-TM-RA14 Sub-base Internal 82A-AB-FKA-TM-RA14 82A-BB-FKA-TM-RA14 82A-EB-FKA-TM-RA14 82A-FB-FKA-TM-RA14 82A-GB-FKA-TM-RA14 G3/8" External 82A-AB-FKD-TM-RA14 82A-BB-FKD-TM-RA14 82A-EB-FKD-TM-RA14 82A-FB-FKD-TM-RA14 82A-GB-FKD-TM-RA14 O P T I O N S 82A-AB-000-TM-RA14 - click for dual pressure valves (replace A by C, B by D, E by M, F by L, G by H). Manifold fastening kit : N P

321 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 82 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/4" : 1300 Nl/min (C v 1.3) - G 3/8" : 1350 Nl/min (C v 1.35) 100 cm 3 /min Spare parts : Options : Remote air operated pilot : TM-RA14. NPTF threads. DIMENSIONS 174,7 DOUBLE 164,2 SGLE G1/8 REMOTE PILOT 174,7 DOUBLE 164,2 SGLE G1/8 REMOTE PILOT 1 1/4 NPSM 9,0 EXH COND 126,2 46,0 28,0 27,0 EXH COND G1/8 (OPTION) 17,5 32,0 59,0 26,5 47,0 164,2 G3/8 6,5 96,0 4,5 23,0 12,0 CYL A CYL B 22,5 46,0 ± 0,2 37,0 23,0 18,5 32,0 59,0 2 Ø 5,3 18,5 1/8 105,2 EXT PILOT CYL B 36,0 126,2 60,5 EXH 16,0 CYL A COND 16 14,0 18,5 46,0

322 R e m o t e a i r v a l v e s Series 6200 Individual mounting sub-base Manifold mounting sub-base

323 R e m o t e a i r v a l v e s Series 6200 Function Port size Flow (Max) Individual mounting 4/2-4/3 G1/4" - G3/8" 1600 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxxx-xxx-ra Port size 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre A A B B A A B B B A B A B A B A EX EX EX EX Valve less base 6212C-000-RA 6222C-000-RA 6232C-000-RA 6242C-000-RA Sub-base G1/4" 6212C-171-RA 6222C-181-RA 6232C-181-RA 6242C-181-RA Sub-base G3/8" 6212C-271-RA 6222C-281-RA 6232C-281-RA 6242C-281-RA O P T I O N S 6212C-000-RA click for bottom cylinder ports (replace by 4).

324 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6200 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/4" : 1500 Nl/min (C v 1.5) - G 3/8" : 1600 Nl/min (C v 1.6) 100 cm 3 /min Spare parts : Options : Remote air operator (A side) : R-62004A. Remote air operator (B side) : R-62005A. Seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. DIMENSIONS 89,5 95,8 4,5 80,5 4 Ø 5,3 G1/8 REMOTE PILOT B 26,0 13,0 NI EXH 20,5 41,0 25,5 51,0 G1/8 REMOTE PILOT A 84,3 CYL A CYL A 18,0 10,0 EXH 13,0 G1/4 (OPTION) 4,0 21,3 29,0

325 R e m o t e a i r v a l v e s Series 6200 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G1/4" - G3/8" 1600 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxxx-xxx-ra Port size 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre A A B B A A B B B A B A B A B A EX EX EX EX Valve less base 6212C-000-RA 6222C-000-RA 6232C-000-RA 6242C-000-RA Sub-base G1/4" 6212C-471-RA 6222C-481-RA 6232C-481-RA 6242C-481-RA Sub-base G3/8" 6212C-571-RA 6222C-581-RA 6232C-581-RA 6242C-581-RA O P T I O N S 6212C-000-RA click for bottom cylinder ports (replace by 4). Manifold fastening kit : N P

326 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6200 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/4" : 1500 Nl/min (C v 1.5) - G 3/8" : 1600 Nl/min (C v 1.6) 100 cm 3 /min Spare parts : Options : Remote air operator (A side) : R-62004A. Remote air operator (B side) : R-62005A. Seal between valve and base : Mounting screw valve to base (x4) : Tie-rod (x2) : NPTF threads. DIMENSIONS 12,0 69,9 G1/8 REMOTE PILOT A 40,0 25,4 11,3 CYL A CYL B 21,5 15,0 51,0 6,5 CYL B CYL A 27,0 15,5 EXH 99,4 COND PILOT A 35,5 43,5 25,4 3/8 68,4 G1/8 REMOTE PILOT B 91,0 2 Ø 6,6 45,4 G1/2 101,1

327 R e m o t e a i r v a l v e s Series 6300 Individual mounting sub-base Manifold mounting sub-base

328 R e m o t e a i r v a l v e s Series 6300 Function Port size Flow (Max) Individual mounting 4/2-4/3 G1/4" - G3/8" - G1/2" 3000 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxxx-xxx-ra Port size 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre A A B B A A B B B A B A B A B A EX EX EX EX Valve less base 6312D-000-RA 6322D-000-RA 6332D-000-RA 6342D-000-RA Sub-base G1/4" 6312D-171-RA 6322D-181-RA 6332D-181-RA 6342D-181-RA Sub-base G3/8" 6312D-271-RA 6322D-281-RA 6332D-281-RA 6342D-281-RA Sub-base G1/2" 6312D-371-RA 6322D-381-RA 6332D-381-RA 6342D-381-RA O P T I O N S 6312D-000-RA click for bottom cylinder ports (excluding G 1/2") (replace by 4). click for dual pressure valves (replace by 5).

329 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6300 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator. : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 11 mm G 1/4" : 2000 Nl/min (C v 2.0) - G 3/8" : 2600 Nl/min (C v 2.6) - G 1/2" : 3000 Nl/min (C v 3.0) 100 cm 3 /min Spare parts : Options : Remote air operator (A side) : R-63004A. Remote air operator (B side) : R-63005A. Seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. DIMENSIONS 89,5 95,8 4,5 80,5 4 Ø 5,3 G1/8 REMOTE PILOT B 26,0 13,0 NI EXH 20,5 41,0 25,5 51,0 G1/8 REMOTE PILOT A 84,3 CYL A CYL A 18,0 10,0 EXH 13,0 G1/4 (OPTION) 4,0 21,3 29,0

330 R e m o t e a i r v a l v e s Series 6300 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G1/4" - G3/8" - G1/2" 3000 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxxx-xxx-ra Port size 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre A A B B A A B B B A B A B A B A EX EX EX EX Valve less base 6312D-000-RA 6322D-000-RA 6332D-000-RA 6342D-000-RA Sub-base G1/4" 6312D-471-RA 6322D-481-RA 6332D-481-RA 6342D-481-RA Sub-base G3/8" 6312D-571-RA 6322D-581-RA 6332D-581-RA 6342D-581-RA Sub-base G1/2" 6312D-671-RA 6322D-681-RA 6332D-681-RA 6342D-681-RA O P T I O N S 6312D-000-RA click for bottom cylinder ports (excluding G 1/2") (replace by 4). click for dual pressure valves (replace by 5). Fastening kit : N P

331 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6300 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 11 mm G 1/4" : 2000 Nl/min (C v 2.0) - G 3/8" : 2600 Nl/min (C v 2.6) - G 1/2" : 3000 Nl/min (C v 3.0) 100 cm 3 /min Spare parts : Options : Remote air operator (A side) : R-63004A. Remote air operator (B side) : R-63005A. Seal between valve and base : Mounting screw valve to base (x4) : Tie-rod (x2) : NPTF threads. DIMENSIONS 12,0 69,9 G1/8 REMOTE PILOT A 40,0 25,4 11,3 CYL A CYL B 21,5 15,0 51,0 6,5 CYL B CYL A 27,0 15,5 EXH 99,4 COND PILOT A 35,5 43,5 25,4 G3/8 68,4 G1/8 REMOTE PILOT B 91,0 2 Ø 6,6 45,4 G1/2 101,1

332 R e m o t e a i r v a l v e s Series 6500 Individual mounting sub-base Manifold mounting sub-base

333 R e m o t e a i r v a l v e s Series 6500 Function Port size Flow (Max) Individual mounting 4/2-4/3 G3/8" - G1/2" - G3/4" 5100 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxxx-xxx-ra Port size 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A EX EX EX EX EX Valve 6512B-000-RA 6522B-000-RA 6532B-000-RA 6542B-000-RA 6552B-000-RA less base Sub-base G3/8" 6512B-171-RA 6522B-181-RA 6532B-181-RA 6542B-181-RA 6552B-181-RA Sub-base G1/2" 6512B-271-RA 6522B-281-RA 6532B-281-RA 6542B-281-RA 6552B-281-RA Sub-base G3/4" 6512B-371-RA 6522B-381-RA 6532B-381-RA 6542B-381-RA 6552B-381-RA O P T I O N S 6512B-000-RA click for dual pressure valves (replace by 4).

334 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6500 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 19 mm G 3/8" : 4500 Nl/min (C v 4.5) - G 1/2" : 5000 Nl/min (C v 5.0) - G 3/4" : 5100 Nl/min (C v 5.1) 100 cm 3 /min Spare parts : Options : Remote air operator : R Seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. DIMENSIONS SGLE 116,5 2 Ø 6,7 DOUBLE 112,2 A A/2 CYL A EXH CYL B 101,6 20,6 41,3 29,7 59,4 J G EXH G1/8 REMOTE PILOT A H B 17,3 34,9 G1/8 REMOTE PILOT B F E 67,3 PORT SIZE A B E F G H J G3/8" & G1/2" 69,6 97,4 36,0 17,9 19,0 23,6 25,4 G3/4" 94,5 109,3 40,1 19,2 20,8 35,9 36,6

335 R e m o t e a i r v a l v e s Series 6500 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G3/8" - G1/2" - G3/4" 5100 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxxx-xxx-ra Port size 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A EX EX EX EX EX Valve 6512B-000-RA 6522B-000-RA 6532B-000-RA 6542B-000-RA 6552B-000-RA less base Sub-base G3/8" 6512B-471-RA 6522B-481-RA 6532B-481-RA 6542B-481-RA 6552B-481-RA Sub-base G1/2" 6512B-571-RA 6522B-581-RA 6532B-581-RA 6542B-581-RA 6552B-581-RA Sub-base G3/4" 6512B-671-RA 6522B-681-RA 6532B-681-RA 6542B-681-RA 6552B-681-RA O P T I O N S 6512B-000-RA click for dual pressure valves (excluding G 3/4") (replace by 4). Fastening kit : N P

336 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6500 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 19 mm G 3/8" : 4500 Nl/min (C v 4.5) - G 1/2" : 5000 Nl/min (C v 5.0) - G 3/4" : 5100 Nl/min (C v 5.1) 100 cm 3 /min Spare parts : Options : Remote air operator : R Seal between valve and base : Mounting screw valve to base (x4) : Tie-rod (x2) : NPTF threads. DIMENSIONS G1/8 REMOTE PILOT B 2 Ø 6,7 42,3 60,0 79,0 16,8 78,0 44,5 CYL A CYL B A B 26,5 24,0 89,0 82,0 59,6 5,5 200,3 185,3 G1/8 REMOTE PILOT A CYL A EXH COND. 132,8 61,0 50,5 CYL B 22,0 66,0 48,0 20,5 G1 G3/4 41,5 44,5 34,5 1 1/4 NPSM

337 R e m o t e a i r v a l v e s Series 6600 Individual mounting sub-base Manifold mounting sub-base

338 R e m o t e a i r v a l v e s Series 6600 Function Port size Flow (Max) Individual mounting 4/2-4/3 G3/4" - G1" 9600 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxxx-xxx-ra Port size 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A EX EX EXH EXH EXH Valve 6612A-000-RA 6622A-000-RA 6632A-000-RA 6642A-000-RA 6652A-000-RA less base Sub-base G3/4" 6612A-271-RA 6622A-281-RA 6632A-281-RA 6642A-281-RA 6652A-281-RA Sub-base G1" 6612A-371-RA 6622A-381-RA 6632A-381-RA 6642A-381-RA 6652A-381-RA O P T I O N S 6612A-000-RA click for dual pressure valves (replace by 4).

339 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6600 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 24 mm G 3/4" : 9000 Nl/min (C v 9.0) - G 1" : 9600 Nl/min (C v 9.6) 100 cm 3 /min Spare parts : Options : Remote air operator : R-A3004. Pressure seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. DIMENSIONS 183,4 SGLE & DOUBLE REMOTE G1/8 PILOT G1/8 REMOTE PILOT 137,4 P-A P-B G1/2 LET FOR DUAL PRESSURE 59,0 37,0 24,0 EXH 60,0 45,0 24,0 60,0 40,0 51,0 49,0 20,0 53,0 15,0

340 R e m o t e a i r v a l v e s Series 6600 Function Port size Flow (Max) Manifold mounting 4/2-4/3 G3/4" - G1" 9600 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxxx-xxx-pm-m0114 Port size 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre 4/3 Pressure centre A A B B A A B B B A B A B A B A B A B A EX EX EXH EXH EXH Valve 6612A-000-PM-M A-000-PM-M A-000-PM-M A-000-PM-M A-000-PM-M0114 less base Sub-base G3/4" 6612A-471-PM-M A-481-PM-M A-481-PM-M A-481-PM-M A-481-PM-M0114 Sub-base G1" 6612A-571-PM-M A-581-PM-M A-581-PM-M A-581-PM-M A-581-PM-M0114 O P T I O N S 6612A-000-PM-M0114 click for dual pressure valves (excluding G 1") (replace by 4). Fastening kit : N P

341 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 6600 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 24 mm G 3/4" : 9000 Nl/min (C v 9.0) - G 1" : 9600 Nl/min (C v 9.6) 100 cm 3 /min Spare parts : Options : Remote air operator : R-A3004. Pressure seal between valve and base : Mounting screw valve to base (x4) : Tie-rod (x2) : Remote air pilot : PM-M0114. NPTF threads. DIMENSIONS G 1/8" PILOT 249,7 DOUBLE SOLENOID 119,9 70,0 CYL A 161,4 CYL B 60,0 32,0 EXH CONDUIT 40,5 50,5 67,5 81,5 22,0 52,0 50,0 108,0 ± 0,2 G1 1/4 LET & EXHAUST 12,0 50,0 54,0 129,8 237,8 SGLE SOLENOID 1 NPSM CONDUIT PORT OPTIONAL G3/4 & G1 BOTTOM CYLDER PORTS AVAILABLE 48,0 42,0 2 MTG HOLES CYL B 54,0 129,8 24,0 CYL A 129,8 30,0 56,0 169,0 ± 0,1 G1 1/4 BOTTOM LET PORT - OPTIONAL

342 R e m o t e a i r v a l v e s Series 2700 Individual mounting sub-base

343 R e m o t e a i r v a l v e s Series 2700 Function Port size Flow (Max) Individual mounting 4/2-4/3 G3/4" - G1" - G1 1/4" - G1 1/2" Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset xxxxx-x Port size Pilot air 4/2 Single operator 4/2 Double operator 4/3 Closed centre 4/3 Open centre A A B B A A B B B A B A B A B A Valve EX EX EX EX less base 2701G G G G-3 Sub-base G3/4" 2721G G G G-3 Sub-base G1" Internal 2731G G G G-3 Sub-base G1 1/4" 2751G G G G-3 Sub-base G1 1/2" 2761G G G G-3 Valve less base 2701G G G G-4 Sub-base G3/4" 2721G G G G-4 Sub-base G1" External 2731G G G G-4 Sub-base G1 1/4" 2751G G G G-4 Sub-base G1 1/2" 2761G G G G-4

344 R e m o t e a i r v a l v e s Series 1800 Individual mounting Inline Manifold mounting cylinder ports in valve with shut-off valve

345 R e m o t e a i r v a l v e s Series 1800 Function Port size Flow (Max) Individual mounting 5/2-5/3 G1/4" 1400 Nl/Min Inline OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset 180xxx-xxx-xxxx Port size 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre 5/3 Pressure centre A 3 2 B A 3 2 B B 2 3 A B 2 3 A B 2 3 A G1/4" Air pilot port : G 1/8. Options : click for side pilot port (replace code 0003 by 0010) (2 positions valves only).

346 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 1800 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 14 bar Single operator and 3 positions : 1.4 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/4" - G 3/8" : 1400 Nl/min (C v 1.4) 50 cm 3 /min Spare parts : Options : Remote air operator (2 positions) : Remote air operator (3 positions) : NPTF threads. G3/8 threads. DIMENSIONS 50, ,7 G1/8 B A 47, ,4 63,5 26, ,51 G1/8 30,0 25,4,98 1,

347 R e m o t e a i r v a l v e s Series 1800 Function Port size Flow (Max) Circuit bar mounting 5/2-5/3 G1/4" 1300 Nl/Min cylinder ports in valve OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset 180xxx-xxx-xxxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Port size 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre 5/3 Pressure centre A 3 2 B A 3 2 B B 2 3 A B 2 3 A B 2 3 A G1/4" Air pilot port : G 1/8. HOW TO ORDER CIRCUIT BAR ** Port size (Spacing 31 mm) G3/8" EBM800A-xxxx-xx Standard circuit bar EBM800A-001B-XX Circuit bar with flow regulators (two per station) EBM800A-002B-XX * * Other options available. Consult factory. XX = Number of stations (03=3 stations) Options : Note : click for side pilot port (replace code 0003 by 0010) (2 positions valves only). click for valves mounted on base at the factory (add -9 to the model number).

348 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 1800 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 14 bar Single operator and 3 positions : 1.4 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/4" - G 3/8" : 1300 Nl/min (C v 1.3) 50 cm 3 /min Spare parts : Options : Remote air operator (2 positions) : Remote air operator (3 positions) : Blanking plate : M NPTF threads. Isolation of inlet and/or exhaust. G3/8 threads. DIMENSIONS 63,5 7,0 Ø 6,7 2 MTG HOLES 50,8 44, ,7 EX EX ,0 12,7 15,0 12, EX EX 18,5 B 4 5 EXH EXH A 15,5 47,7 89,2 31,0 31,5 7,0 84,0 12,0 42,0 72,0 FLOW CONTROL G3/8 G1/8,51 G1/8 60,3 73,1 30,0 9,6 Ø 5,1 MTG. HOLE 26,9,98 1,078 25,

349 R e m o t e a i r v a l v e s Series 1800 Function Port size Flow (Max) Circuit bar mounting 5/2-5/3 G1/4" 1300 Nl/Min with shut-off valve OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset 180xxx-xxx-xxxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Port size 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre 5/3 Pressure centre A 3 2 B A 3 2 B B 2 3 A B 2 3 A B 2 3 A G1/4" Air pilot port : G 1/8. HOW TO ORDER CIRCUIT BAR ** Port size (Spacing 31 mm) G3/8" EBI800A-xxxx-xx Standard circuit bar EBI800A-001B-XX Circuit bar with flow regulators (2 per station) EBI800A-002B-XX * * Other options available. Consult factory. XX = Number of stations (03=3 stations) Options : Note : click for side pilot port (replace code 0003 by 0010) (2 positions valves only). click for valves mounted on base at the factory (add -9 to the model number).

350 Series 1800 Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 14 bar Single operator and 3 positions : 1.4 to 10 bar Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/4" - G 3/8" : 1300 Nl/min (C v 1.3) 50 cm 3 /min DIMENSIONS % 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS T E C H N I C A L D A T A Spare parts : Options : Remote air operator (2 positions) : Remote air operator (3 positions) : Blanking plate : M Shut-off valve : M NPTF threads. Isolation of inlet. G3/8 threads. 63,5 50,8 G1/8,51 G1/8 44, ,7 B A 47,7 4 5,98 92,7 26,9 1, ,0 SHOWN OPEN POSITION G3/8 13,0 19,0 26,0 3 2 SHOWN CLOSED PORITION ,3 73,1 9, Ø 5,1 MTG. HOLE Ø 4 MTG HOLES 9,5 19,0 19,0 111,0 40,0 71,0

351 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 2700 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 35 mm G 3/4" : Nl/min (C v 11.5) - G 1" : Nl/min (C v 13.4) - G 1 1/4" : Nl/min (C v 15.4) - G 1 1/2" : Nl/min (C v 15.9) 100 cm 3 /min Spare parts : Options : Remote air operator : R-0016B. Pressure seal between valve and base : Mounting screw valve to base (x4) : NPTF threads. DIMENSIONS G1/8 EXT. PILOT SUPPLY 206,2 B C "P-B" D EXH "P-A" 17,5 E 158,8 CYL B CYL A PORT SIZE A B C D E 76,2 63,5 A B A G3/4" 95,3 132,3 28,4 25,4 63,5 B A G1" G1 1/4" 114,3 148,3 23,9 30,2 76,2 EXH G1 1/2" 69,9 4 x Ø 10,4 MTG. HOLES OPTIONAL BOTTOM PORTS G3/4

352 R e m o t e a i r v a l v e s Series ISO 1 Individual mounting sub-base Manifold mounting sub-base

353 R e m o t e a i r v a l v e s Series ISO 1 Function Port size Flow (Max) Individual mounting & Manifold mounting 5/2-5/3 G1/4" - G3/8" 1600 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset MV-A1C-Bxxx SGLE PRESSURE VALVES Air spring 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre Internal MV-A1C-B External MV-A1C-B121 MV-A1C-B221 MV-A1C-B322 MV-A1C-B321 DUAL PRESSURE VALVES Air spring 5/2 Single operator 5/2 Double operator 5/3 Pressure centre Internal port 3 MV-A1C-B Internal port 5 MV-A1C-B External MV-A1C-B141 MV-A1C-B241 MV-A1C-B341 Note : ISO valves are delivered w/o base.

354 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 1 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 10 mm G 1/4" - G 3/8" : 1600 Nl/min (C v 1.6) 100 cm 3 /min Spare parts : Remote air operator 2 positions : R-A1010. Remote air operator 3 positions : R-A1005B. Pressure seal between valve and base : Mounting screw body to base (x4) : DIMENSIONS C L G1/8 EXTERNAL PILOT ,0 25,0 25,0 50,0 85,0 100,0 14,0 22,0 26,0 96,1 G1/8 REMOTE PILOT 16,0 G3/ ,0 26,0 121,0 32,5 40,0 113,0 3,0 13,0 68,0 13,0 Ø 6,5 2 MTG HOLES 22,0 21,0 26,0 Ø 6,3 2 MTG HOLES 50,0 12,0 11, ,0 62,0 4 14,0 12, , ,0 24,75 51,0 ± 0,2 50,0 85,0 100,0 OPTIONAL BOTTOM PORTS OPTIONAL BOTTOM PORTS 60,0 100,0 121,0 6,0

355 R e m o t e a i r v a l v e s Series ISO 2 Individual mounting sub-base Manifold mounting sub-base

356 R e m o t e a i r v a l v e s Series ISO 2 Function Port size Flow (Max) Individual mounting & Manifold mounting 5/2-5/3 G3/8" - G1/2" 3000 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset MV-A2B-Bxxx SGLE PRESSURE VALVES Air spring 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre Internal MV-A2B-B External MV-A2B-B121 MV-A2B-B221 MV-A2B-B322 MV-A2B-B321 DUAL PRESSURE VALVES Air spring 5/2 Single operator 5/2 Double operator 5/3 Pressure centre Internal port 3 MV-A2B-B Internal port 5 MV-A2B-B External MV-A2B-B141 MV-A2B-B241 MV-A2B-B341 Note : ISO valves are delivered w/o base.

357 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 2 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 15 mm G 3/8" - G 1/2" : 3000 Nl/min (C v 3.0) 100 cm 3 /min Spare parts : Remote air operator : R-A3004. Pressure seal between valve and base : Mounting screw body to base (x4) : DIMENSIONS 133,0 SGL. & DBL. REMOTE AIR 133,0 SGL. & DBL. REMOTE AIR G1/8 REMOTE PILOT 3, ,0 32,0 23,0 119,7 54,0 20, ,0 42,0 50,5 135,6 32,0 60,0 G1/8 REMOTE PILOT G1/2-3 PORTS 34,0 34,0 16,0 62,0 12,0 3 88,0 36, ,0 75,0 16,0 Ø 7,5 2 MTG. HOLES 14,0 14,5 32,0 30,0 70,0 26,0 23,0 34, ,0 9,0 Ø 6,5 2 MTG. HOLES 30,5 52,0 64,0 ± 0,2 7,0 62,0 98,0 112,0 OPTIONAL BOTTOM PORTS OPTIONAL BOTTOM PORTS 112,0 139,0

358 R e m o t e a i r v a l v e s Series ISO 3 Individual mounting sub-base Manifold mounting sub-base

359 R e m o t e a i r v a l v e s Series ISO 3 Function Port size Flow (Max) Individual mounting & Manifold mounting 5/2-5/3 G1/2" - G3/4" 6300 Nl/Min sub-base OPERATIONAL BENEFITS 1. Balanced spool, immune to variations of pressure. 2. Short stroke with high flow. 3. The piston (booster) provides maximum shifting forces. 4. Powerful return thanks to the combination of mechanical and air springs. 5. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Low leakage rate. HOW TO ORDER Reset MV-A3B-Bxxx SGLE PRESSURE VALVES Air spring 5/2 Single operator 5/2 Double operator 5/3 Closed centre 5/3 Open centre Internal MV-A3B-B External MV-A3B-B121 MV-A3B-B221 MV-A3B-B322 MV-A3B-B321 DUAL PRESSURE VALVES Air spring 5/2 Single operator 5/2 Double operator 5/3 Pressure centre Internal port 3 MV-A3B-B Internal port 5 MV-A3B-B External MV-A3B-B141 MV-A3B-B241 MV-A3B-B341 Note : ISO valves are delivered w/o base.

360 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 3 T E C H N I C A L D A T A Fluid : Pressure range : Air signal pressure : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Single operator and 3 positions : 1.8 to 10 bar main valve pressure Double operator : 0.7 to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 24 mm G 1/2" - G 3/4" : 6300 Nl/min (C v 6.3) 100 cm 3 /min Spare parts : Remote air operator : R-A3004. Pressure seal between valve and base : Mounting screw body to base (x4) : DIMENSIONS ,4 46,0 33,0 27,0 G1/8 REMOTE PILOT 45, ,5 20,5 49,0 49,0 168,0 45,0 140,0 22,0 43,5 55,0 35,0 17,5 15,0 32, ,0 21, ,0 5 Ø 8,3-4 MTG. HOLES 39,5 79,0 15,0 49,0 49,0 78,0 156,0 OPTIONAL BOTTOM PORTS

361 Mechanically and manually operated valves Series 1100 Individual mounting Inline Manifold mounting sub-base

362 Mechanically and manually operated valves Series 1100 Function Port size Flow (Max) Individual mounting 3/2 NO-NC, 2/2 NO-NC G1/8" - G1/4" 180 Nl/Min Inline OPERATIONAL BENEFITS 1. Short stroke with high flow. 2. Powerful return spring. HOW TO ORDER Reset xxxxx-xxx Port size Universal valve NC only valve 2 2 G1/8" G1/4" A-XXX 1117A-XXX A-XXX 1167A-XXX MECHANICAL OPERATOR XXX Code Description Code Description Code Description 011 Cam roller parallel to ports 1 & Lever locking pull perpendicular to ports 1 & Push button 012 Cam roller perpendicular to ports 1 &2 024 Lever non-locking pull perpendicular to ports 1 & Push button (panel mounting) 013 Lever cam parallel to ports 1 & Lever locking push parallel to ports 1 & Push button with guard 014 Lever cam perpendicular to ports 1 & Lever non-locking push parallel to ports 1 & Palm button 021 Lever locking push perpendicular to ports 1 & Lever locking pull parallel to ports 1 & Palm button (panel mounting) 022 Lever non-locking push perpendicular to ports 1 & Lever non-locking pull parallel to ports 1 & Palm button with guard.

363 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 1100 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm G 1/8" - G1/4 : 180 Nl/min (C v 0.18) 50 cm 3 /min Spare parts : Options : Operator : 1100A-XXX (see codification). NPTF threads. DIMENSIONS STROKE 1, ,09 2,2 OVERTRAVEL 1,0 Ø 11,1 ROLLER 58,0 4,75 10 OVERTRAVEL 4,2 40 STROKE 33,6 4,7 35,9 021 / / ,4 Ø 12,7 ROLLER 011 / 012 PANEL MT HEX PANEL MT. W/GUARD # # ,0 27,6 W/GUARD 031 / 032 Ø 5 29,9 28,7 036 / ,6 40,0 Ø 69, PORT SIZE G1/8" G1/4" A 28,4 29,8 B 12,7 13,3 C 14,0 12,7 D 8,0 9,9 H 23,2 24,1 #2 #3 24,9 #1 17,8 B 21,2 A C D Ø 4,4 4, ,2 33,0 1 H

364 Mechanically and manually operated valves Series 1100 Function Port size Flow (Max) Manifold mounting 3/2 NO-NC, 2/2 NO-NC G1/8" 140 Nl/Min sub-base OPERATIONAL BENEFITS 1. Short stroke with high flow. 2. Powerful return spring. HOW TO ORDER Reset xxxxx-xxx Port size Universal valve NC only valve CYL CYL Valve less base Sub-base G1/8" EXH 1130A-XXX 1136A-XXX EXH 1170A-XXX 1176A-XXX MECHANICAL OPERATOR XXX Code Description Code Description 025 Lever locking push parallel to ports 1 & Push button 026 Lever non-locking push parallel to ports 1 & Lever non-locking pull parallel to ports 1 & Lever locking pull parallel to ports 1 & 2 End plate kit (Port size G1/4") : A P.

365 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 1100 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 10 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2 mm G 1/8" : 140 Nl/min (C v 0.14) 50 cm 3 /min Spare parts : Options : Operator : 1100A-XXX (see codification). Function plate : A Pressure seal between bases : Tie-rod (x2) : NPTF threads. DIMENSIONS G1/8 CYL. PORT ,0 17,6 CYL 35,9 59,5 14,2 25,4 ± 0,1 025 / 028 EXH 25,4 63,5 G1/4 LET & EXHAUST PORTS EACH END 12,7 17,8 MT G SLOT Ø 6,6 MAX. TYP. 9,7 ± 0,2 31,5 CYL EXH 2,3 4,8 15,7 32,7 OPTIONAL G1/8 BOTTOM PORTS 46,6 PANEL. MT. W/GUARD 25,0 27, HEX 5,7

366 Mechanically and manually operated valves Series 1800 Individual mounting Inline Circuit bar mounting cylinder ports in valve

367 Mechanically and manually operated valves Series 1800 Function Port size Flow (Max) Individual mounting 5/2 G1/4" 1400 Nl/Min Inline OPERATIONAL BENEFITS 1. Short stroke with high flow. 2. Powerful return force. 3. Bonded spool with minimum friction, shifting in a glass-like finished bore. 4. Wiping effect eliminates sticking. 5. Long service life. HOW TO ORDER Reset 18xxxx-115-xxxx Port size Single operator Double operator A 3 2 B A 3 2 B G1/4" XXXX XXXX-115-XXXX MECHANICAL OPERATOR XXXX Code Description Code Description Code Description 0111 Cam roller parallel to ports 2 & Lever non-locking pull perpendicular to body 0033 Push button with guard 0112 Cam roller perpendicular to ports 2 & Lever locking push parallel to body 0034 Push Pull 0013 Lever cam perpendicular to ports 2 & Lever non-locking push parallel to body 0035 Push Pull (panel mounting) 0014 Lever cam parallel to ports 2 & Lever locking pull parallel to body 0036 Palm button 0021 Lever locking push perpendicular to body 0028 Lever non-locking pull parallel to body 0037 Palm button (panel mounting) 0022 Lever non-locking push perpendicular to body 0031 Push button 0038 Palm button with guard 0023 Lever locking pull perpendicular to body 0032 Push button (panel mounting) 0039 Push Pull palm button

368 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 1800 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 14 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/4" : 1400 Nl/min (C v 1.4) 50 cm 3 /min Spare parts : Options : Operator : 18XXXX (see codification). NPTF threads. DIMENSIONS 50, ,7 2,84 STROKE 2,36 OVERTRAVEL 12,7 DIA. ROLLER 4,7 1,5 TO 4,5 PANEL THICKNESS Ø 25 HOLE PANEL MT. B A 47, ,4 63,5 30,0 45,2 30 PUSH 30 PULL 0111 / / 0039 Ø 19 46,7 W/GUARD 44,4 73,1 1,5 TO 4,5 PANEL THICKNESS Ø 25 HOLE PANEL MT. 25,4 69,8 W/GUARD 22,3 50,8 10 OVERTRAVEL STROKE 40 12,7 DIA. 2,3 ROLLER 5,5 60,3 73,1 37, / 0024 LEVER PERPENDICULAR TO BODY CYL. PORTS 0025 / 0028 CYL. PORTS 43, / 0035 W/GUARD 2,3 4, ,6 Ø 5,1 MTG. HOLE /

369 Mechanically and manually operated valves Series 1800 Function Port size Flow (Max) Circuit bar mounting 5/2 G1/4" 1300 Nl/Min cylinder ports in valve OPERATIONAL BENEFITS 1. Short stroke with high flow. 2. Powerful return force. 3. Bonded spool with minimum friction, shifting in a glass-like finished bore. 4. Wiping effect eliminates sticking. 5. Long service life. HOW TO ORDER Reset 18xxxx-175-xxxx HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTG Port size Single operator Double operator A 3 2 B A 3 2 B G1/4" XXXX XXXX-175-XXXX MECHANICAL OPERATOR XXXX Code Description Code Description 0025 Lever locking push parallel to body 0028 Lever non-locking pull parallel to body 0026 Lever non-locking push parallel to body 0034 Push Pull 0027 Lever locking pull parallel to body 0031 Push button HOW TO ORDER CIRCUIT BAR ** Port size (Spacing 31 mm) G3/8 Standard circuit bar EBM800A-001B-XX Circuit bar with flow regulators (2 per station) EBM800A-002B-XX * * Other options available. Consult factory. XX = Number of stations (03=3 stations) Note : click for valves mounted on base at the factory (add -9 to the model number).

370 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series 1800 T E C H N I C A L D A T A Fluid : Pressure range : Lubrication : Filtration : Temperature range : Orifice : Flow (at 6 bar, P=1bar) : Leak rate : Compressed air, vacuum, inert gases Vacuum to 14 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 7 mm G 1/4" : 1300 Nl/min (C v 1.3) 50 cm 3 /min Spare parts : Options : Operator : 18XXXX (see codification). Blanking plate : M NPTF threads. Isolation of inlet and/or exhaust. DIMENSIONS 30,0 30,0 30,0 63,5 7,0 50,8 44,4 EX EX ,0 12, EX EX 15,0 Ø 6,7 2 MTG. HOLES 12,7 18,5 B EXH EXH A 15,5 12,7 31,0 47,7 Operator A & B 31,0 31,5 7,0 84,0 12,0 42,0 72,0 11,6 FLOW CONTROL G3/8 3-PORTS Ø 19 1,5 TO 4,5 PANEL THICKNESS Ø 25 HOLE 60,3 73,1 69,8 PANEL MT. 9,6 W/ Ø 5,1 MTG. HOLE LEVER 43,6 GUARD PERPENDICULAR TO BODY / / 0035

371 B a s e s a c c o r d i n g t o I S O Series ISO 1 HOW TO ORDER Reset xx-xx-xxx DIVIDUAL BASE Port size Side ports Bottom ports Bottom cylinder ports 2 and 4. Bottom port 1 G1/4" MB-A1C-121 MB-A1C-123 MB-A1C-122 MB-A1C-124 G3/8" MB-A1C-131 MB-A1C-133 MB-A1C-132 MB-A1C-134 DIVIDUAL BASE ACCORDG TO VDMA Port size Side ports Bottom ports G1/4" HB-A1A-A HB-A1A-B MANIFOLD BASE Port size Side ports Bottom ports Bottom cylinder ports 2 and 4. Bottom port 1 G1/4" MM-A1C-121 MM-A1C-123 MM-A1C-122 MM-A1C-124 G3/8 MM-A1C-131 MM-A1C-133 MM-A1C-132 MM-A1C-134 Manifold fastening kit : N MANIFOLD BASE ACCORDG TO VDMA Port size Bottom cylinder ports 2 and 4 G1/4" HM-A1A-C End plate kit : HM-A1A-D.

372 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 1 DIMENSIONS Individual D 5599/1 Manifold G1/8 EXTERNAL PILOT 2 4 G1/ ,0 22,0 26,0 36,0 EXTERNAL PILOT 26,0 25,0 25,0 100,0 16,0 G3/8 3 PORTS 26,0 121,0 26,0 50,5 42,5 40,0 32,5 6,0 13,0 68,0 13,0 Ø 6,5 2 MTG. HOLES 22,0 21,0 26,0 Ø 6,3 2 MTG. HOLES 50,0 12,0 11, ,0 14,0 62,0 12,75 25, ,0 24,75 51,0 ± 0,2 VDMA 32 7, G 1/4 50,0 85,0 100, ,5 21,5 OPTIONAL BOTTOM PORTS 5, OPTIONAL BOTTOM PORTS 48 60,0 100,0 121, ,0 10,5 23,5 G 1/4 G 1/8 G 1/4 58

373 B a s e s a c c o r d i n g t o I S O Series ISO 2 HOW TO ORDER Reset xx-xx-xxx DIVIDUAL BASE Port size Side ports Bottom ports Bottom cylinder ports 2 and 4. Bottom port 1 G3/8" MB-A2B-121 MB-A2B-123 MB-A2B-122 MB-A2B-124 G1/2" MB-A2B-131 MB-A2B-133 MB-A2B-132 MB-A2B-134 DIVIDUAL BASE ACCORDG TO VDMA Port size Side ports Bottom ports G3/8 HB-A2B-A HB-A2B-B MANIFOLD BASE Port size Side ports Bottom ports Bottom cylinder ports 2 and 4. Bottom port 1 G3/8" MM-A2B-121 MM-A2B-123 MM-A2B-122 MM-A2B-124 G1/2 MM-A2B-131 MM-A2B-133 MM-A2B-132 MM-A2B-134 Manifold fastening kit : N MANIFOLD BASE ACCORDG TO VDMA Port size Bottom cylinder ports 2 and 4 G3/8 HM-A2B-C End plate kit : HM-A2B-D.

374 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 2 DIMENSIONS Individual D 5599/1 Manifold G1/8 EXTERNAL PILOT 38, ,0 32,0 42,0 49,0 54,0 20, ,0 42,0 50,5 16,0 62,0 12,0 3 32,0 60,0 88,0 36, ,0 75,0 16,0 Ø 7,5 2 MTG. HOLES G1/8 EXTERNAL PILOT G1/2-3 PORTS EACH SIDE 14,0 14,5 32,0 30,0 26,0 34,0 34,0 70, ,0 34, ,0 9,0 Ø 6,5 2 MTG. HOLES 30,5 52,0 64,0 ± 0,2 7,0 62,0 98,0 112,0 OPTIONAL BOTTOM PORTS OPTIONAL BOTTOM PORTS 112,0 139,0 VDMA G3/8" 26,0 6, ,0 30,0 13 G3/8" 14,0 G1/8" 74 G3/8"

375 B a s e s a c c o r d i n g t o I S O Series ISO 3 HOW TO ORDER Reset xx-xx-xxx DIVIDUAL BASE Port size Side ports Bottom ports Bottom cylinder ports 2 and 4. Bottom port 1 G1/2" MB-A3B-121 MB-A3B-123 MB-A3B-122 MB-A3B-124 G3/4" MB-A3B-131 MB-A3B-133 MB-A3B-132 MB-A3B-134 DIVIDUAL BASE ACCORDG TO VDMA Port size Side ports Bottom ports G1/2" HB-A3B-A HB-A3B-B MANIFOLD BASE ACCORDG TO VDMA Port size Bottom cylinder ports 2 and 4 G1/2" HM-A3B-C End plate kit : HM-A3B-D.

376 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series ISO 3 DIMENSIONS Individual ISO D 5599/1 15,0 140,0 35,0 17,5 70,0 Ø 8,3 4 MTG. HOLES 46,0 33,0 27,0 G1/8 EXTERNAL PILOT 32, , ,5 55,0 21,0 22, ,0 45,0 15,0 49,0 49,0 78,0 20,5 20,5 156,0 49,0 49,0 39,5 79,0 OPTIONAL BOTTOM PORTS Manifold VDMA G1/2" 17,0 6, ,0 22,0 18 G1/2" 17,0 G1/8" 90 G1/2"

377 P r e s s u r e r e g u l a t o r s Series PR82A Sandwich pressure regulator with manual adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PR82A-xxxx REGULATORS FOR "PLUG-" VALVES Gauges Single pressure Regulator A end Same regulated pressure to ports A and B Dual pressure Regulator A end Regulated pressure to port A * Dual pressure Regulator B end Regulated pressure to port B * Dual pressure Dual regulator Two regulated pressures to ports A and B * No gauge PR82A-GADA PR82A-GCDA PR82A-GBDA PR82A-GDDA Gauge parallel to regulator PR82A-GACA PR82A-GCCA PR82A-GBCA PR82A-GDCA Gauge perpendicular to regulator PR82A-GABA PR82A-GCBA PR82A-GBBA PR82A-GDBA REGULATORS FOR "NON PLUG-" AND REMOTE AIR VALVES Gauges Single pressure Regulator A end Same regulated pressure to ports A and B Dual pressure Regulator A end Regulated pressure to port A * Dual pressure Regulator B end Regulated pressure to port B * Dual pressure Dual regulator Two regulated pressures to ports A and B * No gauge PR82A-HADA PR82A-HCDA PR82A-HBDA PR82A-HDDA Gauge parallel to regulator PR82A-HACA PR82A-HCCA PR82A-HBCA PR82A-HDCA Gauge perpendicular to regulator PR82A-HABA PR82A-HCBA PR82A-HBBA PR82A-HDBA * To be used with dual pressure valves.

378 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR82A T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 1080 Nl/min (C v 1.08) Spare parts : Pressure regulator : PR82A-J0AA. DIMENSIONS 215,5 183,3 173,2 20,5 3,5 149,2 G 1/8" (OPTION) 73,5 EXH 208,9 COND 24,5 215,5 183,3 156,2 LOCK G 1/8" (OPTION) 127,2 11,5 G 1/8" (OPTION) 183,2 EXH 51,5 PILOT 25,0 50,0

379 P r e s s u r e r e g u l a t o r s Series PR82A Sandwich pressure regulator with air adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PR82A-xxxx REGULATORS FOR "PLUG-" VALVES Gauges Single pressure Regulator A end Same regulated pressure to ports A and B Dual pressure Regulator A end Regulated pressure to port A * Dual pressure Regulator B end Regulated pressure to port B * Dual pressure Dual regulator Two regulated pressures to ports A and B * No gauge PR82A-DADA PR82A-DCDA PR82A-DBDA PR82A-DDDA Gauge parallel to regulator PR82A-DACA PR82A-DCCA PR82A-DBCA PR82A-DDCA Gauge perpendicular to regulator PR82A-DABA PR82A-DCBA PR82A-DBBA PR82A-DDBA REGULATORS FOR "NON PLUG-" AND REMOTE AIR VALVES Gauges Single pressure Regulator A end Same regulated pressure to ports A and B Dual pressure Regulator A end Regulated pressure to port A * Dual pressure Regulator B end Regulated pressure to port B * Dual pressure Dual regulator Two regulated pressures to ports A and B * No gauge PR82A-EADA PR82A-ECDA PR82A-EBDA PR82A-EDDA Gauge parallel to regulator PR82A-EACA PR82A-ECCA PR82A-EBCA PR82A-EDCA Gauge perpendicular to regulator PR82A-EABA PR82A-ECBA PR82A-EBBA PR82A-EDBA * To be used with dual pressure valves.

380 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR82A T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 1080 Nl/min (C v 1.08) Spare parts : Pressure regulator : PR82A-F0AA. DIMENSIONS 171,5 161,3 151,3 149,2 73,5 G 1/8" G 1/8" EXH 41,4 208,9 COND 15,2 41,4 13, ,5 161,3 134,2 127,2 PILOT EXH 161,2 51,5 25,0 50,0

381 P r e s s u r e r e g u l a t o r s Series PR62C Sandwich pressure regulator with manual adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PR62C-xxxx REGULATORS FOR "PLUG-" VALVES Gauges No gauge Non filled gauge Glycerine filled gauge Single pressure Regulator B end Same regulated pressure to ports A and B PR62C-21AA PR62C-21FA PR62C-21BA REGULATORS FOR "NON PLUG-" AND REMOTE AIR VALVES Gauges No gauge Non filled gauge Glycerine filled gauge Single pressure Regulator B end Same regulated pressure to ports A and B PR62C-31AA PR62C-31FA PR62C-31BA

382 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR62C T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 1250 Nl/min (C v 1.25) Spare parts : Pressure regulator : PR62C-01AA. DIMENSIONS G 1/8" (OPTION) 162,8 EXH 53,5 147,7 EXH COND 228,4 54,0 G 1/8" (OPTION) 194,3 EXH 165,7 EXH COND 260,0 57,0 ± 0,2

383 P r e s s u r e r e g u l a t o r s Series PR63C Sandwich pressure regulator with manual adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PR63C-xxxx REGULATORS FOR "PLUG-" VALVES Gauges Single pressure Regulator A end Same regulated pressure to ports A and B Single pressure Regulator B end Same regulated pressure to ports A and B Dual pressure Regulator A end Regulated pressure to port B * Dual pressure Regulator B end * Dual pressure Dual regulator * Regulated pressure to port A Two regulated pressures to ports A and B No gauge PR63C-22AA PR63C-21AA PR63C-24AA PR63C-23AA PR63C-25AA Glycerine filled gauge on regulator PR63C-22BA PR63C-21BA PR63C-24BA PR63C-23BA PR63C-25BA Glycerine filled gauge opposite to regulator PR63C-22CA PR63C-21CA PR63C-24CA PR63C-23CA PR63C-25CA Glycerine filled gauges both ends PR63C-24DA PR63C-23DA PR63C-25DA REGULATORS FOR "NON PLUG-" AND REMOTE AIR VALVES Gauges Single pressure Regulator A end Same regulated pressure to ports A and B Single pressure Regulator B end Same regulated pressure to ports A and B Dual pressure Regulator A end Regulated pressure to port B * Dual pressure Regulator B end * Dual pressure Dual regulator * Regulated pressure to port A Two regulated pressures to ports A and B No gauge PR63C-32AA PR63C-31AA PR63C-34AA PR63C-33AA PR63C-35AA Glycerine filled gauge on regulator PR63C-32BA PR63C-31BA PR63C-34BA PR63C-33BA PR63C-35BA Glycerine filled gauge opposite to regulator PR63C-32CA PR63C-31CA PR63C-34CA PR63C-33CA PR63C-35CA Glycerine filled gauges both ends PR63C-34DA PR63C-33DA PR63C-35DA * To be used with dual pressure valves.

384 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR63C T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2400 Nl/min (C v 2.4) Spare parts : Pressure regulator : PR63C-01AA. DIMENSIONS (OPTION) 290,2 238,5 G 1/8" (OPTION) 50,5 162,1 COND 93,5 EXH 253,1 236,6

385 P r e s s u r e r e g u l a t o r s Series PR63C Sandwich pressure regulator with air adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PR63C-xxxx REGULATORS FOR "PLUG-" VALVES Gauges Single pressure Regulator A end Same regulated pressure to ports A and B Single pressure Regulator B end Same regulated pressure to ports A and B Dual pressure Regulator A end Regulated pressure to port B * Dual pressure Regulator B end * Dual pressure Dual regulator * Regulated pressure to port A Two regulated pressures to ports A and B No gauge PR63C-2BAA PR63C-2AAA PR63C-2DAA PR63C-2CAA PR63C-2EAA Glycerine filled gauge on regulator PR63C-2BBA PR63C-2ABA PR63C-2DBA PR63C-2CBA PR63C-2EBA Glycerine filled gauge opposite to regulator PR63C-2BCA PR63C-2ACA PR63C-2DCA PR63C-2CCA PR63C-2ECA Glycerine filled gauges both ends PR63C-2DDA PR63C-2CDA PR63C-2EDA REGULATORS FOR "NON PLUG-" AND REMOTE AIR VALVES Gauges Single pressure Regulator A end Same regulated pressure to ports A and B Single pressure Regulator B end Same regulated pressure to ports A and B Dual pressure Regulator A end Regulated pressure to port B * Dual pressure Regulator B end * Dual pressure Dual regulator * Regulated pressure to port A Two regulated pressures to ports A and B No gauge PR63C-3BAA PR63C-3AAA PR63C-3DAA PR63C-3CAA PR63C-3EAA Glycerine filled gauge on regulator PR63C-3BBA PR63C-3ABA PR63C-3DBA PR63C-3CBA PR63C-3EBA Glycerine filled gauge opposite to regulator PR63C-3BCA PR63C-3ACA PR63C-3DCA PR63C-3CCA PR63C-3ECA Glycerine filled gauges both ends PR63AC-3DDA PR63C-3CDA PR63C-3EDA * To be used with dual pressure valves.

386 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR63C T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2400 Nl/min (C v 2.4) Spare parts : Pressure regulator : PR63C-0AAA. DIMENSIONS (OPTION) 230,2 206,5 G 1/8" (OPTION) 50,5 162,1 G1/8 COND 93,5 EXH 221,1 204,6

387 P r e s s u r e r e g u l a t o r s Series PR65B Sandwich pressure regulator with manual adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PR65B-xxxx REGULATORS FOR "PLUG-" VALVES Gauges Single pressure Regulator A end Same regulated pressure to ports A and B Single pressure Regulator B end Same regulated pressure to ports A and B Dual pressure Regulator A end Regulated pressure to port B * Dual pressure Regulator B end * Dual pressure Dual regulator * Regulated pressure to port A Two regulated pressures to ports A and B No gauge PR65B-22AA PR65B-21AA PR65B-24AA PR65B-23AA PR65B-25AA Glycerine filled gauge on regulator PR65B-22BA PR65B-21BA PR65B-24BA PR65B-23BA PR65B-25BA Glycerine filled gauge opposite to regulator PR65B-22CA PR65B-21CA PR65B-24CA PR65B-23CA PR65B-25CA Glycerine filled gauges both ends PR65B-24DA PR65B-23DA PR65B-25DA REGULATORS FOR "NON PLUG-" AND REMOTE AIR VALVES Gauges Single pressure Regulator A end Same regulated pressure to ports A and B Single pressure Regulator B end Same regulated pressure to ports A and B Dual pressure Regulator A end Regulated pressure to port B * Dual pressure Regulator B end * Dual pressure Dual regulator * Regulated pressure to port A Two regulated pressures to ports A and B No gauge PR65B-32AA PR65B-31AA PR65B-34AA PR65B-33AA PR65B-35AA Glycerine filled gauge on regulator PR65B-32BA PR65B-31BA PR65B-34BA PR65B-33BA PR65B-35BA Glycerine filled gauge opposite to regulator PR65B-32CA PR65B-31CA PR65B-34CA PR65B-33CA PR65B-35CA Glycerine filled gauges both ends PR65B-34DA PR65B-33DA PR65B-35DA * To be used with dual pressure valves.

388 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR65B T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 4000 Nl/min (C v 4.0) Spare parts : Pressure regulator : PR65B-01AA. DIMENSIONS 277,2 72,5 205,3 128,8 292,8 364,0 89,0

389 P r e s s u r e r e g u l a t o r s Series PR65B Sandwich pressure regulator with air adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PR65B-xxxx REGULATORS FOR "PLUG-" VALVES Gauges Single pressure Regulator A end Same regulated pressure to ports A and B Single pressure Regulator B end Same regulated pressure to ports A and B Dual pressure Regulator A end Regulated pressure to port B * Dual pressure Regulator B end * Dual pressure Dual regulator * Regulated pressure to port A Two regulated pressures to ports A and B No gauge PR65B-2BAA PR65B-2AAA PR65B-2DAA PR65B-2CAA PR65B-2EAA Glycerine filled gauge on regulator PR65B-2BBA PR65B-2ABA PR65B-2DBA PR65B-2CBA PR65B-2EBA Glycerine filled gauge opposite to regulator PR65B-2BCA PR65B-2ACA PR65B-2DCA PR65B-2CCA PR65B-2ECA Glycerine filled gauges both ends PR65B-2DDA PR65B-2CDA PR65B-2EDA REGULATORS FOR "NON PLUG-" AND REMOTE AIR VALVES Gauges Single pressure Regulator A end Same regulated pressure to ports A and B Single pressure Regulator B end Same regulated pressure to ports A and B Dual pressure Regulator A end Regulated pressure to port B * Dual pressure Regulator B end * Dual pressure Dual regulator * Regulated pressure to port A Two regulated pressures to ports A and B No gauge PR65B-3BAA PR65B-3AAA PR65B-3DAA PR65B-3CAA PR65B-3EAA Glycerine filled gauge on regulator PR65B-3BBA PR65B-3ABA PR65B-3DBA PR65B-3CBA PR65B-3EBA Glycerine filled gauge opposite to regulator PR65B-3BCA PR65B-3ACA PR65B-3DCA PR65B-3CCA PR65B-3ECA Glycerine filled gauges both ends PR65B-3DDA PR65B-3CDA PR65B-3EDA * To be used with dual pressure valves.

390 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PR65B T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 4000 Nl/min (C v 4.0) Spare parts : Pressure regulator : PR65B-0AAA. DIMENSIONS 212,2 72,5 205,3 128,8 227,8 234,0 89,0

391 P r e s s u r e r e g u l a t o r s Series PRA1A Sandwich pressure regulator with manual adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PRA1A-xxxx REGULATORS FOR TERNAL PILOT APPLICATIONS Gauges Single pressure Regulator 14 end Same regulated pressure to ports 2 and 4 Single pressure Regulator 12 end Same regulated pressure to ports 2 and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 12 end * Dual pressure Dual regulator * Regulated pressure to port 2 Two regulated pressures to ports 2 and 4 No gauge PRA1A-GAAA PRA1A-GCAA PRA1A-GBAA PRA1A-GDAA PRA1A-GEAA Gauge parallel to regulator PRA1A-GADA PRA1A-GCDA PRA1A-GBDA PRA1A-GDDA PRA1A-GEDA Gauge perpendicular to regulator PRA1A-GABA PRA1A-GCBA PRA1A-GBBA PRA1A-GDBA PRA1A-GEBA Two gauges parallel to regulator PRA1A-GEEA Two gauges perpendicular to regulator PRA1A-GECA REGULATORS FOR EXTERNAL PILOT AND REMOTE AIR APPLICATIONS Gauges Single pressure Regulator 14 end Same regulated pressure to ports 2 and 4 Single pressure Regulator 12 end Same regulated pressure to ports 2 and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 12 end * Dual pressure Dual regulator * Regulated pressure to port 2 Two regulated pressures to ports 2 and 4 No gauge PRA1A-HAAA PRA1A-HCAA PRA1A-HBAA PRA1A-HDAA PRA1A-HEAA Gauge parallel to regulator PRA1A-HADA PRA1A-HCDA PRA1A-HBDA PRA1A-HDDA PRA1A-HEDA Gauge perpendicular to regulator PRA1A-HABA PRA1A-HCBA PRA1A-HBBA PRA1A-HDBA PRA1A-HEBA Two gauges parallel to regulator PRA1A-HEEA Two gauges perpendicular to regulator PRA1A-HECA * - To be used with dual pressure valves. - Valve code is : MV-A1C-AX5X-PM-XXYZZ

392 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRA1A T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 1000 Nl/min (C v 1.0) Spare parts : Pressure regulator : PRA1A-J0AA. DIMENSIONS 297,3 241,0 214,7 241,0 162,8

393 P r e s s u r e r e g u l a t o r s Series PRA1A Sandwich pressure regulator with air adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PRA1A-xxxx REGULATORS FOR TERNAL PILOT APPLICATIONS Gauges Single pressure Regulator 14 end Same regulated pressure to ports 2 and 4 Single pressure Regulator 12 end Same regulated pressure to ports 2 and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 12 end * Dual pressure Dual regulator * Regulated pressure to port 2 Two regulated pressures to ports 2 and 4 No gauge PRA1A-DAAA PRA1A-DCAA PRA1A-DBAA PRA1A-DDAA PRA1A-DEAA Gauge parallel to regulator PRA1A-DADA PRA1A-DCDA PRA1A-DBDA PRA1A-DDDA PRA1A-DEDA Gauge perpendicular to regulator PRA1A-DABA PRA1A-DCBA PRA1A-DBBA PRA1A-DDBA PRA1A-DEBA Two gauges parallel to regulator PRA1A-DEEA Two gauges perpendicular to regulator PRA1A-DECA REGULATORS FOR EXTERNAL PILOT AND REMOTE AIR APPLICATIONS Gauges Single pressure Regulator 14 end Same regulated pressure to ports 2 and 4 Single pressure Regulator 12 end Same regulated pressure to ports 2 and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 12 end * Dual pressure Dual regulator * Regulated pressure to port 2 Two regulated pressures to ports 2 and 4 No gauge PRA1A-EAAA PRA1A-ECAA PRA1A-EBAA PRA1A-EDAA PRA1A-EEAA Gauge parallel to regulator PRA1A-EADA PRA1A-ECDA PRA1A-EBDA PRA1A-EDDA PRA1A-EEDA Gauge perpendicular to regulator PRA1A-EABA PRA1A-ECBA PRA1A-EBBA PRA1A-EDBA PRA1A-EEBA Two gauges parallel to regulator PRA1A-EEEA Two gauges perpendicular to regulator PRA1A-HECA * - To be used with dual pressure valves. - Valve code is : MV-A1C-AX5X-PM-XXYZZ

394 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRA1A T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 1000 Nl/min (C v 1.0) Spare parts : Pressure regulator : PRA1A-F0AA. DIMENSIONS ,8 219,0 171,6 162,8

395 P r e s s u r e r e g u l a t o r s Series PRA2C Sandwich pressure regulator with manual adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PRA2C-xxxx REGULATORS FOR TERNAL PILOT APPLICATIONS Gauges Single pressure Regulator 14 end Same regulated pressure to ports 2 and 4 Single pressure Regulator 12 end Same regulated pressure to ports 2 and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 12 end * Dual pressure Dual regulator * Regulated pressure to port 2 Two regulated pressures to ports 2 and 4 No gauge PRA2C-1AAA PRA2C-1EAA PRA2C-1BAA PRA2C-1FAA PRA2C-1JAA With gauge PRA2C-1ADA PRA2C-1EDA PRA2C-1BDA PRA2C-1FDA Two gauges PRA2C-1BEA PRA2C-1FEA PRA2C-1JEA REGULATORS FOR EXTERNAL PILOT AND REMOTE AIR APPLICATIONS Gauges Single pressure Regulator 14 end Same regulated pressure to ports 2 and 4 Single pressure Regulator 12 end Same regulated pressure to ports 2 and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 12 end * Dual pressure Dual regulator * Regulated pressure to port 2 Two regulated pressures to ports 2 and 4 No gauge PRA2C-2AAA PRA2C-2EAA PRA2C-2BAA PRA2C-2FAA PRA2C-2JAA With gauge PRA2C-2ADA PRA2C-2EDA PRA2C-2BDA PRA2C-2FDA Two gauges PRA2C-2BEA PRA2C-2FEA PRA2C-2JEA * - To be used with dual pressure valves. - Valve code is : MV-A2B-AX5X-PM-XXYZZ

396 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRA2C T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2300 Nl/min (C v 2.3) Spare parts : Pressure regulator : PRA2C-30AA. DIMENSIONS 315,4 260,8 230,1 260,8 183,9

397 P r e s s u r e r e g u l a t o r s Series PRA2C Sandwich pressure regulator with air adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PRA2C-xxxx REGULATORS FOR TERNAL PILOT APPLICATIONS Gauges Single pressure Regulator 14 end Same regulated pressure to ports 2 and 4 Single pressure Regulator 12 end Same regulated pressure to ports 2 and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 12 end * Dual pressure Dual regulator * Regulated pressure to port 2 Two regulated pressures to ports 2 and 4 No gauge PRA2C-4AAA PRA2C-4EAA PRA2C-4BAA PRA2C-4FAA PRA2C-4JAA With gauge PRA2C-4ADA PRA2C-4EDA PRA2C-4BDA PRA2C-4FDA Two gauges PRA2C-4BEA PRA2C-4FEA PRA2C-4JEA REGULATORS FOR EXTERNAL PILOT AND REMOTE AIR APPLICATIONS Gauges Single pressure Regulator 14 end Same regulated pressure to ports 2 and 4 Single pressure Regulator 12 end Same regulated pressure to ports 2 and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 12 end * Dual pressure Dual regulator * Regulated pressure to port 2 Two regulated pressures to ports 2 and 4 No gauge PRA2C-5AAA PRA2C-5EAA PRA2C-5BAA PRA2C-5FAA PRA2C-5JAA With gauge PRA2C-5ADA PRA2C-5EDA PRA2C-5BDA PRA2C-5FDA Two gauges PRA2C-5BEA PRA2C-5FEA PRA2C-5JEA * - To be used with dual pressure valves. - Valve code is : MV-A2B-AX5X-PM-XXYZZ

398 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRA2C T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 2300 Nl/min (C v 2.3) Spare parts : Pressure regulator : PRA2C-60AA. DIMENSIONS 228,8 198,0 228,8 251,0 183,9

399 P r e s s u r e r e g u l a t o r s Series PRA3B Sandwich pressure regulator with manual adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PRA3B-xxxx REGULATORS FOR TERNAL PILOT APPLICATIONS Gauges Single pressure Regulator 14 end Same regulated pressure to ports 2 and 4 Single pressure Regulator 12 end Same regulated pressure to ports 2 and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 12 end * Dual pressure Dual regulator * Regulated pressure to port 2 Two regulated pressures to ports 2 and 4 No gauge PRA3B-1AAA PRA3B-1EAA PRA3B-1BAA PRA3B-1FAA PRA3B-1JAA With gauge PRA3B-1ADA PRA3B-1EDA PRA3B-1BDA PRA3B-1FDA Two gauges PRA3B-1BEA PRA3B-1FEA PRA3B-1JEA REGULATORS FOR EXTERNAL PILOT AND REMOTE AIR APPLICATIONS Gauges Single pressure Regulator 14 end Same regulated pressure to ports 2 and 4 Single pressure Regulator 12 end Same regulated pressure to ports 2 and 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 12 end * Dual pressure Dual regulator * Regulated pressure to port 2 Two regulated pressures to ports 2 and 4 No gauge PRA3B-2AAA PRA3B-2EAA PRA3B-2BAA PRA3B-2FAA PRA3B-2JAA With gauge PRA3B-2ADA PRA3B-2EDA PRA3B-2BDA PRA3B-2FDA Two gauges PRA3B-2BEA PRA3B-2FEA PRA3B-2JEA * - To be used with dual pressure valves. - Valve code is : MV-A3B-AX5X-PM-XXYZZ

400 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRA3B T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 5400 Nl/min (C v 5.4) Spare parts : Pressure regulator : PRA3B-30AA. DIMENSIONS 408,0 323,6 291,0 323,6 141,4

401 P r e s s u r e r e g u l a t o r s Series PRA3B Sandwich pressure regulator with air adjust. OPERATIONAL BENEFITS 1. Easy mounting : saves on installation costs in comparison with inline regulators. 2. Allows to have compact, all-included units. 3. Large orifice provides high flow. 4. Various functions available. 5. Simple, reliable and solid design. HOW TO ORDER Reset PRA3B-xxxx REGULATORS FOR TERNAL PILOT APPLICATIONS Gauges Single pressure Regulator 14 end Same regulated pressure to ports 2 and 4 Singola pressione. Regolatore lato 12. Regolazione utilizzi 2 e 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 12 end * Dual pressure Dual regulator * Regulated pressure to port 2 Two regulated pressures to ports 2 and 4 No gauge PRA3B-4AAA PRA3B-4EAA PRA3B-4BAA PRA3B-4FAA PRA3B-4JAA With gauge PRA3B-4ADA PRA3B-4EDA PRA3B-4BDA PRA3B-4FDA Two gauges PRA3B-4BEA PRA3B-4FEA PRA3B-4JEA REGULATORS FOR EXTERNAL PILOT AND REMOTE AIR APPLICATIONS Gauges Single pressure Regulator 14 end Same regulated pressure to ports 2 and 4 Singola pressione. Regolatore lato 12. Regolazione utilizzi 2 e 4 Dual pressure Regulator 14 end Regulated pressure to port 4 * Dual pressure Regulator 12 end * Dual pressure Dual regulator * Regulated pressure to port 2 Two regulated pressures to ports 2 and 4 No gauge PRA3B-5AAA PRA3B-5EAA PRA3B-5BAA PRA3B-5FAA PRA3B-5JAA With gauge PRA3B-5ADA PRA3B-5EDA PRA3B-5BDA PRA3B-5FDA Two gauges PRA3B-5BEA PRA3B-5FEA PRA3B-5JEA * - To be used with dual pressure valves. - Valve code is : MV-A3B-AX5X-PM-XXYZZ

402 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PRA3B T E C H N I C A L D A T A Fluid : Pressure range : Regulating range : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=1bar) : Compressed air, inert gases 0 to 10 bar 0.5 to 8.5 bar Not required, if used select a medium aniline point lubricant (between 80 C and 100 C) 40 µ -18 C to +50 C 5400 Nl/min (C v 5.4) Spare parts : Pressure regulator : PRA3B-60AA. DIMENSIONS 291,0 259,0 344,0 291,0 141,4

403 P r e s s u r e c o n t r o l s y s t e m s Series PMPP Pressure control system with analogical command signal. OPERATIONAL BENEFITS 1. The use of an analogical command signal brings increased accuracy in pressure control. 2. A compact unit gathering all components saves room and installation costs. 3. The analog and logic (TTL) outputs allow for constant pressure monitoring from the control unit. 4. Infinite number of pressures available. C O M P O N E N T S The Proportional Multi-Pressure Pak is made of the following components : one proportional pressure controller PPC5A for pressure selection. one (or more) directional valves to be selected as a function of the flow required. one remote air pressure regulator for main pressure control. FIELDS OF APPLICATION The Proportional Multi-Pressure Pak is suitable for all applications requiring many different pressures, a continuous pressure control and progressive pressure rise or descent. The numerous possibilities of pressures, flows and pressure ranges makes it easy to find the best appropriate configuration. This system has proved its abilities in the automotive industry, for the operation of welding grips and robots. Many other applications are fulfilled, like pressure selection for any supply network or machinery, force control in a cylinder, tension control on a drum, painting robots control (combination of high flow and accurate pressure control),... OPERATION PROPORTIONAL PRESSURE CONTROLLER PPC5A This is the pressure selector of the whole system. Depending on the command signal (0 to 10 V or 4 to 20 ma), the PPC5A will adjust the pressure to the requested value. REMOTE AIR SANDWICH REGULATOR The outlet port of the PPC5A gives a pressure signal to the sandwich regulator. This one in turn will regulate the main pressure as a function of the command signal. DIRECTIONAL VALVE(S) Depending on the application, one or more directional valves will be used. For instance : a 4/2 valve for the welding control (with the regulated pressure) and another one (with the network pressure) for the command of the robot arm (grip movements).

404 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series PMPP T E C H N I C A L D A T A Pressure range : Output pressure : 2 to 8 bar Standard : 0.5 to 7 bar, other ranges upon request. Series Port size Flow Height Width Length Weight 82 G1/4" - G3/8" 900 Nl/Min (C v 0.9) 158,75 mm 190,50 mm 228,60 mm 3,6 kg 6300 G3/8" - G1/2" 2100 Nl/Min (C v 2.1) 165,10 mm 254,00 mm 254,00 mm 5,7 kg 6500 G1/2" - G3/4" 3500 Nl/Min (C v 3.5) 203,20 mm 273,00 mm 254,00 mm 6,8 kg ISO 1 G1/4" - G3/8" 1100 Nl/Min (C v 1.1) ISO 2 G3/8" - G1/2" 2100 Nl/Min (C v 2.1) ISO 3 G1/2" - G3/4" 5000 Nl/Min (C v 5.0) HOW TO ORDER? Please consult factory for the selection of best appropriate PMPP.

405 P r e s s u r e c o n t r o l s y s t e m s Series MPP Pressure control system with digital command signal. OPERATIONAL BENEFITS 1. The use of a digital command signal brings easy installation and use. 2. A compact unit gathering all components saves room and installation costs. 3. This system is the alternative to proportional valves, if no more than six different pressures are required. C O M P O N E N T S The Multi-Pressure Pak is made of the following components : one 35 Series manifold for the pressure selection. one (or more) directional valves to be selected as a function of the flow required. one remote air pressure regulator for main pressure control. FIELDS OF APPLICATION The Multi-Pressure Pak is suitable for all applications requiring up to six different pre-determined pressures (no progressive pressure rise or descent). The numerous possibilities of pressures, flows and pressure ranges makes it easy to find the best appropriate configuration. This system has proved its abilities in the automotive industry, for the operation of welding grips and robots. Many other applications are fulfilled, like pressure selection for any supply network or machinery, force control in a cylinder,... OPERATION 35 SERIES MANIFOLD This is the pressure selector of the whole system. Each valve is fitted out with one individual pressure regulator and they are cascade - connected to a single common outlet. When energized, the pressure signal will correspond to the individual pre-determined pressure. REMOTE AIR SANDWICH REGULATOR The common outlet port of the 35 Series manifold gives a pressure signal to the sandwich regulator. This one in turn will regulate the main pressure as a function of the command signal. DIRECTIONAL VALVE(S) Depending on the application, one or more directional valves will be used. For instance : a 4/2 valve for the welding control (with the regulated pressure) and another one (with the network pressure) for the command of the robot arm (grip movements).

406 100% 100% WARRANTY 18 O F P R O D U C T I O N T E S T E D 100% MONTHS Series MPP T E C H N I C A L D A T A Pressure range : Output pressure : 2 to 8 bar Standard : 0.5 to 7 bar, other ranges upon request. Series Port size Flow Height Width Length Weight 82 G1/4" - G3/8" 900 Nl/Min (C v 0.9) 158,75 mm 190,50 mm 228,60 mm 3,6 kg 6300 G3/8" - G1/2" 2100 Nl/Min (C v 2.1) 165,10 mm 254,00 mm 254,00 mm 5,7 kg 6500 G1/2" - G3/4" 3500 Nl/Min (C v 3.5) 203,20 mm 273,00 mm 254,00 mm 6,8 kg ISO 1 G1/4" - G3/8" 1100 Nl/Min (C v 1.1) ISO 2 G3/8" - G1/2" 2100 Nl/Min (C v 2.1) ISO 3 G1/2" - G3/4" 5000 Nl/Min (C v 5.0) HOW TO ORDER? Please consult factory for the selection of best appropriate MPP.

407 P r e s s u r e c o n t r o l s y s t e m s Series PPC5A Proportional pressure controller. OPERATIONAL BENEFITS 1. Reliable operation, using two MAC 34 Series with balanced poppet. 2. Low power consumption. 3. Rugged enclosure. 4. Not affected by vibrations. 5. Accuracy : ± 1.5 % full scale or ± 0.5 % (upon request). 6. Can be stand alone or used in combination with our remote air sandwich regulators. 7. Analog command signal and output. 8. No hysteresis (compensated). HOW TO ORDER Reset PPC5A-ABA-xxxx-xxx-xx PPC5A-ABA-AGAB-XXX-ZZ * Pressure range Command signal Standard Analog and logic outputs 0-7 bar 0-10 V PPC5A-ABA-AGAB-BAA-ZZ PPC5A-ABA-AGAB-BBB-YY 4-20 ma PPC5A-ABA-AGAB-DAA-ZZ PPC5A-ABA-AGAB-DBB-YY 0-4 bar 0-10 V PPC5A-ABA-BGAB-BAA-ZZ PPC5A-ABA-BGAB-BBB-YY 4-20 ma PPC5A-ABA-BGAB-DAA-ZZ PPC5A-ABA-BGAB-DBB-YY 0-2 bar 0-10 V PPC5A-ABA-CGAB-BAA-ZZ PPC5A-ABA-CGAB-BBB-YY 4-20 ma PPC5A-ABA-CGAB-DAA-ZZ PPC5A-ABA-CGAB-DBB-YY Connector/ 1 m 2 m 4 m Connector/ 1 m 2 m 4 m Wire length ZZ ZZ ZZ Wire length YY YY YY MI 4 P BB BD BE MI 6 P CB CD CE MICRO 4 P EB ED EE MICRO 6 P FB FD FE Flying leads (4 flying leads) HB HD HE Flying leads (6 flying leads) JB JD JE * Other options available. Consult factory. O P T I O N S PPC5A-ABA-AGAB-BAA-ZZ - B: external sense.

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Series ISO Individual mounting Valve only No base non plug-in Conform to ISO 99/ Valve only No base plug-in Conform to ISO 99/2 Manifold mounting Valve

More information

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves Direct solenoid and solenoid pilot operated valves Individual mounting Valve only No base non plug-in Conform to ISO 99/ Valve only No base plug-in Conform to ISO 99/2 Manifold mounting Valve only No base

More information

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section 8

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section 8 CURRENT Technology Page Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section 8 Direct solenoid and solenoid pilot operated valves 9 Remote air valves 181 Mechanically

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated

More information

Section 2 Proportional Quick Exhaust

Section 2 Proportional Quick Exhaust V A L V E S Section 2 Proportional Quick Exhaust OPERATION OF THE PQE 1. The pilot operated regulator and the PPC5C are both fed from a common inlet. 2. The out port of the PPC5C sends pressure to the

More information

Nugget 120 V14 Series

Nugget 120 V14 Series Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus

More information

Nugget 120 V14 Series

Nugget 120 V14 Series Nugget 0 V Series /2 & /3 Valves Solenoid and Pilot Operated G 1 4 High flow compact valves Sub-base and low profile manifolds Light weight, long life corrosion resistant materials Multipole and Fieldbus

More information

SPCH/ Blowing block

SPCH/ Blowing block > > for linear stretch blow moulding machines > > Compact and safe design > > Best suited for PET bottles up to litres, depending on cycle time Technical features Medium: Compressed air (purity class 3..3

More information

PVQ 13 A2 R SE 1 S 20 C-11 D

PVQ 13 A2 R SE 1 S 20 C-11 D PVQ - Variable Displacement Piston Pump PVQ 13 A2 R SE 1 S 2 C-11 D 1 2 3 4 6 7 8 9 1 1 Model Series PVQ Inline Piston Pump Variable Volume Quiet Series 4 Rotation Viewed from shaft end R Right hand, standard

More information

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces

More information

FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG

FEPA PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG PNEUMATICALLY AND SOLENOID ACTUATED VALVES, ONE UNIT MOUNTED TYPE VPG TECHNICAL CHARACTERISTICS Number of ways / positions : 3/2, 3/3, 5/2, 5/3, 5/4 Nominal sizes (ND) : 4, 6, 9, 12 Medium : compressed

More information

TECHNICAL CHARACTERSTICS

TECHNICAL CHARACTERSTICS and solenoid valves spool version GM - GL series Type of valves with dorsal consumption: GM-...series with integrated connections GL-...series without connections TECHNICAL CHARACTERSTICS Ambient temperature:

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is

More information

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version

2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version 2/2- and 3/2-way Rocker Solenoid Valve - bistable (impulse) version Type 6624 Impulse can be combined with... 10mm width orifice DN 0.8 to 1.2 with pressure range vacuum to 5bar medium separation, for

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

Fast Switching Valves

Fast Switching Valves Fast Switching Valves Ultra Fast and Highly Repeatable MH, MH3 and MH4 MH: Flow rate of 100 l/min and ms response MH3: Flow rate of 00 l/min and 3 ms response MH4: Flow rate of 400 l/min and 3.5 ms response

More information

3-Way Safety Block DSV

3-Way Safety Block DSV 3-Way Safety Block DSV DSV 10 - M DSV 10 - M - T-ball DSV 10 - EY 1. Description 1.1. GENERAL The 3-way safety block is used to shut off and discharge hydraulic accumulators or consumers. It complies with

More information

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R

PILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure a secondary part of a hydraulic circuit. Pressure is mataed

More information

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application:

MV-01. Features. 2/2-way Solenoid Valve for Fluids. Description: Application: MV-01 2/2-way Solenoid Valve for Fluids Description: Features / Nominal diameters 1/4-2 / Pressure up to 10 bar / 24 V DC and all common AC variants / Forced-lifting The pilot-controlled full-way valve

More information

Inverse Proportional Pressure-Relief Cartridge, Size 10

Inverse Proportional Pressure-Relief Cartridge, Size 10 Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated Key features and overview Function Normally closed solenoid valve with diaphragm and forced lifting. When the solenoid is energised, the differential pressure from the secondary side of the diaphragm is

More information

Proportional Throttle Cartridges, Size 16

Proportional Throttle Cartridges, Size 16 Proportional Throttle Cartridges, Size 16 Q max = 5 l/min, p max = 5 bar, Q N max = 14 l/min at p 1 bar Two-Stage, with Seat-Valve Shut-Off 1 Description Normally closed Seat-valve shut-off from 1 Compact

More information

filtered air without lubricant. If lubricated air is used, it is recommended to use ISOVG32 oil and to never interrupt lubrication.

filtered air without lubricant. If lubricated air is used, it is recommended to use ISOVG32 oil and to never interrupt lubrication. > Series EN valves and solenoid valves Valves and Solenoid valves Series EN, CC - CO - CP With outlets on the body - For individual or manifold assembly Size 16-19 mm» Mounting on any flat surface» Reduced

More information

II 2G EEx ia IIC T6. Ignition protection class

II 2G EEx ia IIC T6. Ignition protection class ATEX General information According to 94/9/EC, a device that is to be used in an environment at risk of explosion may only be brought into the market if it satisfies the standards specified in the norm.

More information

Electrically Operated Pressure-Relief Cartridge, Size 10

Electrically Operated Pressure-Relief Cartridge, Size 10 Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description

More information

Pneumatic valve islands

Pneumatic valve islands Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented

More information

Smooth Vent Valve. XVD Series

Smooth Vent Valve. XVD Series Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 5 bar Direct acting, electrically operated 1 Description inverse proportional pressure-relief valves are direct acting screw-in cartridges

More information

Hand lever valves VHER

Hand lever valves VHER Hand lever valves VHER Hand lever valves VHER Key features Powerful Flexible Practical -M- Flow 170 3800 l/min 4/3-way valve mid-position closed mid-position exhausted mid-position pressurised Connections:

More information

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS GENERAL CHARACTERISTICS CONSTRUCTION FEATURES ENCLOSURE OPERATING TEMPERATURE 20 C/+60 C COVER Diecast aluminium (anodised) WEIGHT CSN 5 3.5 kg CSN 8 5 kg CSN

More information

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4" to 1" NPT SERIES.

4 qwer 2/2 3/2 4/2. Intrinsically Safe. Air and Inert Gas Intrinsically Safe Valves Brass, or Stainless Steel Bodies 1/4 to 1 NPT SERIES. qwer Air and Inert Gas Valves Brass, or Stainless Steel Bodies 1/" to 1" NPT Features Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting

More information

Intrinsically safe solenoid valves on/off controls - ATEX certification

Intrinsically safe solenoid valves on/off controls - ATEX certification www.atos.com Table E130-17/E Intrinsically safe solenoid valves on/off controls - ATEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-0611/WP/6

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE

More information

VALVES ISO 5599/1, SERIES IPV-ISV

VALVES ISO 5599/1, SERIES IPV-ISV VALVES ISO 99/1, SERIES IPV-ISV The assembly surface dimensions of ISO1 and ISO2 valves are to ISO99-1. They are available in the -way versions with 2 and 3 positions and with pneumatic or solenoid actuation.

More information

Valves ISO 5599/1 ISO 1, 5/2-5/3, electrically operated, with CNOMO pilot

Valves ISO 5599/1 ISO 1, 5/2-5/3, electrically operated, with CNOMO pilot ISO 1, - 5/3, electrically operated, with CNOMO pilot Executions 0300 ISO1E50 NOTE: FOR VALVES WITH PILOT IN LINE SEE PAGE.111.1 Technical data 03030 ISO1E51 03037 ISO1E5 03031 ISO1E70 0303 ISO1E71 03043

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min, p max = 3 bar Direct acting, electrically operated 1 Description proportional pressure-relief valves are direct acting screw-in cartridges

More information

Air preparation units

Air preparation units Overview Description Page Characteristics Dimensions Order instructions Type overview unit three-piece 44, 45, 48 52 6 unit two piece 44, 45, 48 52 6 Filter-regulator 44, 45, 48 53 6 Filter-water-separator

More information

Goodyear Polyglas Tire Date Coding

Goodyear Polyglas Tire Date Coding Goodyear Polyglas Tire Date Coding M A R C U S A N G H E L R I C K S A U V E Ever wonder what the date code is on your Goodyear tires and if they are original? This article is written to answer that, and

More information

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

V83 series Redundant valve manifold systems - Modular with bypass 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability > > Modular design - Maxseal valves > > able terminations inside coil housing

More information

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)

Flow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi) Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for

More information

Regulator A * end with by-pass end plate B end. PR93A-DEAA Gage with face perpendicular to manual operator Gage with face parallel to manual operator

Regulator A * end with by-pass end plate B end. PR93A-DEAA Gage with face perpendicular to manual operator Gage with face parallel to manual operator P r e s s u r e r e g u l a t o r s Series Sandwich pressure regulator with air pilot adjust OPERATIONAL BENEFITS 1. Easy mounting: saves on installation costs in comparison with inline regulators. 2.

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Type N-10, N-11 Hazardous Area Non-incendive Transmitters

Type N-10, N-11 Hazardous Area Non-incendive Transmitters Electronic Pressure Catalog > Hazardous Area > N-10, N-11 Type N-10, N-11 Hazardous Area Non-incendive Transmitters Applications Natural gas compressors Wellhead monitoring Pipeline pressure General industrial

More information

Smooth Vent Valve XVD. Series

Smooth Vent Valve XVD. Series Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08 Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm Port connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

Series 1, 3 and 4 Cv = /8" and 1/4" Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position

Series 1, 3 and 4 Cv = /8 and 1/4 Ported Manually Operated Valves. 3-way/2-position, 5-way/2-position, 5-way/3position Cv =.52 -.73 Series, 3 and 4 Cv =.52.3 /8" and /4" Ported Manually Operated Valves 3-way/2-position, 5-way/2-position and 5-way/3-position Ports /8 and /4" NPTF The Series (/8 & /4", 3-way/2-position and

More information

VSD03M DIRECTIONAL CONTROL VALVES

VSD03M DIRECTIONAL CONTROL VALVES NFPA SIZE D03 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e.

More information

Inverse Proportional Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4 Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional

More information

Series ZL. Multistage Ejector. New models! ZL212 large flow rate type and ZL112 with valve. ZX ZR ZM ZY ZH ZU ZL ZF ZP ZCU

Series ZL. Multistage Ejector. New models! ZL212 large flow rate type and ZL112 with valve. ZX ZR ZM ZY ZH ZU ZL ZF ZP ZCU MULTISTAGE EJECTOR Multistage Ejector Series ZL ZX ZR ZM ZY ZH ZU ZL ZF Z ZCU acuum related New models! ZL212 large flow rate type and ZL112 with valve. 3.7-1 Multistage Ejector Series ZL112/212 Energy

More information

Valves to ISO 5599/1 standards pilot and solenoid actuated size

Valves to ISO 5599/1 standards pilot and solenoid actuated size Series UDS ISO pilot and solenoid actuated size 1 - - 3 DESCRIPTION Valves series "UDS ISO" are produced in the and pneumatic functions according to the interface to ISO 5599/1 standards and they are mounted

More information

seriesuds ISO Valves to ISO 5599/1 standard

seriesuds ISO Valves to ISO 5599/1 standard seriesuds ISO Valves to ISO 5599/1 standard pilot and solenoid actuated sizes 1 - - 3 DESCRIPTION Valves series UDS ISO are produced in the and pneumatic functions according to the interface to ISO 5599/1

More information

Series 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position

Series 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position 3 Cv =.73-2.00 Series 4 Cv=.73-2.00 Air-Pilot operated valves Series 4: 1/8,, 3-way/2-position; 5-way/2-position; 5-way/3-position 1/2 5-way/2-position The pneumatically operated,3-way/2-position, 5-way/2-position

More information

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Proportional Pressure-Relief Cartridge Valve, Size 2...4 Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting

More information

Flow control valves Series RFU - RFO 2/

Flow control valves Series RFU - RFO 2/ CATALOGUE > Release 8.5 > Valves Series RFU - RFO Flow control valves Series RFU - RFO Unidirectional and bidirectional flow control valves Ports: M5, G1/8, G1/4, G3/8 and G1/ Nominal diameter: M5 = 1,5

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Series MX pressure regulators 3/

Series MX pressure regulators 3/ CATALOGUE > Release 8.8 > Series MX regulators Series MX pressure regulators MX2 ports: G/8, G1/2, G/4 - MX ports: G/4, G1 Manifold ports: G1/2 (MX2 only) Modular - Available with built-in pressure gauges

More information

2/ Port G1/4

2/ Port G1/4 CATALOGUE > Release 8.8 > Series ER100 digital electro-pneumatic regulators Series ER100 digital electro-pneumatic regulators Port G1/4 Compact design Digital display Analog and digital input Programmable

More information

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Prop. Pressure-Relief Cart., Size 2 4 Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in

More information

PRESSURE SEQUENCE VALVE TYPE UZK

PRESSURE SEQUENCE VALVE TYPE UZK PRESSURE SEQUENCE VALVE TYPE UZK Size 10, 20, 30 31,5 MPa up to 450 dm 3 /min WK 450 414 04. 2000r. Pressure sequence valves type UZK are used for switching a system or part of a system off when a set

More information

AIR TREATMENT H Z E 0. Air Treatment Units CHARACTERISTICS CODIFICATION KEY. Filter. Ambient temperature Fluid Working pressure Max pressure Size Body

AIR TREATMENT H Z E 0. Air Treatment Units CHARACTERISTICS CODIFICATION KEY. Filter. Ambient temperature Fluid Working pressure Max pressure Size Body NEW - HZE Air Treatment Units CHARACTERISTICS Ambient temperature Working pressure Max pressure Body Knob Ring nut Bowl Bowl guard Filter element Seals Springs Diaphragm CODIFICATION KEY H Z E B 8 G +6

More information

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV Smooth Vent Valve Series Valve / needle valve integrated construction requires only 1/4 the piping space of previous models. Particulates significantly reduced through the use of a metal diaphragm in the

More information

series UDS ISO to ISO 5599/1 standard pilot and solenoid actuated sizes DESCRIPTION TECHNICAL DATA MATERIALS SPARE PARTS

series UDS ISO to ISO 5599/1 standard pilot and solenoid actuated sizes DESCRIPTION TECHNICAL DATA MATERIALS SPARE PARTS series UDS ISO Valves to ISO 5599/1 standard pilot and solenoid actuated sizes 1 - - 3 DESCRIPTION Valves series UDS ISO are produced in the and functions according to the interface to ISO 5599/1 standard

More information

SPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at:

SPOOL VALVES. ISO 15407/1 - Sizes Series PA568-GB-R3. All leafl ets available at: SPOOL VLVS ISO 07/ - Sizes 0-0 Series 8-9 P68-GB-R ll leafl ets available at: www.ascojoucomatic.com FTURS These spool valves which comply with the VDM 6 standard offer the advantage of being smaller than

More information

Liquid level regulating valves Types PMFL / PMFH and SV

Liquid level regulating valves Types PMFL / PMFH and SV Data sheet Liquid level regulating valves Types / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant, a system comprising a liquid level regulating valve

More information

Pilot Check Valve: Metal Body Type

Pilot Check Valve: Metal Body Type INFORMATION Pilot Check Valve: Metal Body Type The use of a metal body improves strength and environmental resistance. Temporary intermediate stops are possible. *1 *1 Precise intermediate stops are not

More information

SDM to 8 sections monoblock valve D1WWDA02A

SDM to 8 sections monoblock valve D1WWDA02A SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or user units. It complies with the relevant safety standards in accordance with

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

Air service units series Y G1/4 to G1

Air service units series Y G1/4 to G1 Air service units series Y Series FY Filter, 12.071 Series RY+ RYP Pressure regulator, 12.076 Series FRY Filter/regulator, 12.080 Series OY Lubricator, 12.083 Series FROY Filter, Regulator, Lubricator

More information

Time-Delay Electropneumatic Applications

Time-Delay Electropneumatic Applications Exercise 3-4 EXERCISE OBJECTIVE & & & To introduce time delays; To describe the operation of a time-delay valve; To describe the operation of a time-delay relay. DISCUSSION Time-Delays Time delays are

More information

Multistage Ejector Series ZL

Multistage Ejector Series ZL Multistage Ejector Series. Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 5% and air consumption reduced % with 3 stage diffuser construction (ersus ø.3, one

More information

Multistage Ejector Series ZL

Multistage Ejector Series ZL Multistage Ejector Series. Energy-saving, large flow rate, 3 stage diffuser construction Suction flow rate increased 5% and air consumption reduced % with 3 stage diffuser construction (ersus ø.3, one

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1. DESCRIPTION 1.1. GENERAL The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies with the relevant safety

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

F l o w c o n T R o l v a l v E S

F l o w c o n T R o l v a l v E S Composite Right Angle Flow Control Valves Series TMCU-TMVU-TMCO- BSP/METRIC Meter In, Meter Out, Needle Orifice G1/8, G1/, G3/8, G1/2 Banjo flow controllers Nominal diameters Ø 2-3.8-5.8-8 The Meter In,

More information

Solenoid Valves VUVG Overview

Solenoid Valves VUVG Overview Solenoid Valves VUVG Overview Universal valve Combination of basic valve and E-boxes Width 10 mm and 14 mm In-line valves VUVG-L and VUVG-S Sub-base valves VUVG-B Internal or external pilot air supply

More information

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New > Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,

More information

References 6 k thermal overload relays, adjustable from 0.11 to 16 A

References 6 k thermal overload relays, adjustable from 0.11 to 16 A s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure

More information

Cover headline. Cover subheadline. Check Valves

Cover headline. Cover subheadline. Check Valves Check Valves Cover headline Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Cover subheadline EATON Screw-In Cartridge Valves E-VLSC-MC-E December

More information

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents

More information

Series K Air service units G 1/8, G 1/4

Series K Air service units G 1/8, G 1/4 Air service units G /8, G /4 Series FK Filter, G /8 G /4.02 Series RK Pressure regulator, G /8 G /4.04 Series FRK Filter/regulator, G /8 G /4.06 Series OK Lubricator, G /8 G /4.08 Series FROK Two piece

More information

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5.

Pressure booster. Air Service Units Series Page. General 5.1. Pressure boosters ø Pressure boosters ø 40 c/w air pressure regulator 5. Series 17 Pressure booster Page General Pressure boosters ø 4 Pressure boosters ø 4 c/w air pressure regulator Pressure booster ø 63 Pressure booster ø 63 c/w air pressure regulator Pressure booster ø

More information

Spool compact valves pilot and solenoid actuated G 1/8 - G 1/4

Spool compact valves pilot and solenoid actuated G 1/8 - G 1/4 Spool compact valves pilot and solenoid actuated G 1/8 - G 1/4 DESCRIPTION Valves series "MEK", in the 5/ and pneumatic functions, have been realized with compact overall dimensions yet assuring high flow.

More information

Safety and Shut-off Block SAF/DSV

Safety and Shut-off Block SAF/DSV Safety and Shut-off Block SAF/DSV 1.1.1 Key to the circuit diagram Circuit diagram The HYDAC safety and shut-off block is used to shut off and discharge hydraulic accumulators or consumers. It complies

More information

Technical Data Sheet TI-F50 Locking Units series KFH

Technical Data Sheet TI-F50 Locking Units series KFH English translation of German original Locking Units series KF Further important practical advice is given in Operating Manual BA-F50., Rod diameter 18 mm 50 mm øz 8 L 2 6 x 6 0 min. 4x30 KF 18 to KF 32,

More information

W60 Spool & Sleeve Valves for ISO Bases (5599/I)

W60 Spool & Sleeve Valves for ISO Bases (5599/I) W60 Spool & Sleeve Valves for ases (59/I) 5/ Valves Single Solenoid Pilot Spring Return,7,,6 W60760 W6076 W60760 W6076 W60760 W6076 W6070 W607 * ase and electrical connector not included. 5/ Valves Double

More information

Pressure decay sensor Pressure decay sensor Flow at 90 psi (6 bars) Tripping point at 90 psi (6 bar) supply Connection Mechanical life Relay C

Pressure decay sensor Pressure decay sensor Flow at 90 psi (6 bars) Tripping point at 90 psi (6 bar) supply Connection Mechanical life Relay C Position Detectors Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com / Pressure decay sensor Pressure decay sensor 8 04 02 Flow at 90 psi (6 bars) Tripping point at 90 psi

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

Precision pressure regulators LRP/LRPS

Precision pressure regulators LRP/LRPS Precision pressure regulators LRP/LRPS q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.05... 2.0 mm ort connection 1/8 or sub-base Type 2871 can be combined with Type 8605 Digital

More information

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators

BL68 - Olympian Plus, plug-in system Filter/regulators and lubricators >> Port size: 3/4... /2 (ISO G/ PTF) >> Complete air processing units pre-assembled, ready to install Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (246 psi) Pressure

More information

HEAVY DUTY PNEUMATIC

HEAVY DUTY PNEUMATIC HEAVY DUTY PNEUMATIC Series A4 MEDIUM DUTY HYDRAULIC Series H4 PERMANENTLY LUBRICATED HEAVY DUTY PNEUMATIC Series L4 586.778.7680 SERIES A4/L4/H4 39 A4/L4/H4 FEATURES 1 1 9 9 12 8 7 5 12 3 13 4 10 2 11

More information

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV

Modulating liquid level regulators, servo-controlled PMFL / PMFH and SV MAKING MODERN LIVING POSSIBLE Technical brochure Modulating liquid level regulators, servo-controlled / PMFH and SV For modulating liquid level control in refrigeration, freezing and air conditioning plant,

More information