Subplate Mtd. Valve Cross Reference
|
|
- Morris Lawrence
- 5 years ago
- Views:
Transcription
1 ubplate Mtd. ross Reference NFP pattern no. IO no. osch EI enison Nachi ontinental Northman Parker Rexroth Rivett Vickers G4V F4-**H-* F4-*K-*02 0 lt. (0HE) 0 lt. (0H) V*03M E*03M V*M E0M V*M P P02 1VW WE6 6***-03 (K)G4V-3 3W WE 6*** W WEH F4-**H-*02 V-2 -G01 -G01 M-G01 -G03 M-G03 G02 G03 31W 31VW G4*-01 G4V-4 (K)G4V- (K)G3V- (K)GV- 6***-0H G F4-**H-*04 V WV16P F4-**H-* F4-**H-* V-86 V*08M E08M *V0M P P06 VM -3-3 V*0M* 40 -G04 -G06 HF()-G06 -G HF()-G G04 G06 G WEH16 61VW WEH22 6***-08 6***-08H 1VW WEH32 G44-02 (obsolete) G4-04 (K)G3V-7 (K)GV-7 G-(H)8 (K)G3V-8 (K)GV-8 G4- (K)G3V- (K)GV- 2F FF2-*H*-02* FM 2F102 ()FT-G02 FG3PK 2FRM F()G-02 2F FF2-*H*-03* 2F103 FT-G03 2FRM16 F()G-03 P F2-PTH-*03 081VP1 R4*03 PR*3M *P Z*** P48**03 R()G-03 P F2-PTH-*06 081V2P1 E*3M R4*06 HT()-G06 PR*6M *20P Z*20** P48**06 R()G-06 P *30P F2-PTH-* R4* HT()-G PR*M Z*30** P48** R()G- R06 (I06) VP3 RI-03 ** G-03 R FE1-P**-06* 081V2P3 RI-06 **20 R FE1-P**-* RI- **30 I08 (RV08) FE1-P**-I06* R6V G-06 I (RV) FE1-P**-I* RM G-
2 02 Parallel Manifold Parallel Flow urve ll mounting hardware is supplied. ee page 62 for itemized list. No. of stations length inch [mm] apx. weight alum apx. weight iron * [4.0] 3 [1.] [92.1] [130.2] 7 [3] [.] [168.3] [206.4] [4.] 19 [9] [244.] [.] 23 [] [282.6] 14 [6] 26 [] [320.7] [14] [38.8] 33 [1] * Length of 01 station with relief cavity is 3.13 [79.4]. Gauge port not available on 01 station [8] 1.63 [396.9] 19 [9] 37 [17] Port code mtg. P,, M, T #-24 UN x 0.6 [14] P M IO 6H x 0.6 [14] P Manifold mtg UN x 0.38 [9.7] P M6 IO 6H x 0.38 [9.7] P pecifications, descriptions, and dimensional data are subject to correction or change without notice or incurring obligation. ownload latest catalog page revisions at Pattern No. of tations pacing Port Threads / luminum T psi 20.7 MPa uctile Iron - 4 Electroless Nickel oated N uctile Iron - 4 Working pressure should be considered in accordance with IO 4413 to determine appropriate material type. P Pattern IO NFP T ee Tech Information Parallel luminum uctile Iron pacing 1 No. of tations inch 38.1 mm P NPTF NI M Port Threads E IO PP IO 1179 IO IO 6149 P & T & G M18 M14 none T PT IO 7 ee next page for available options and ordering codes.
3 - 02 Parallel Manifold Ordering code letter: E F G H J IOLTION ITHYRULI isolation options allow a manifold to have two independent pressure and/or tank ports. Isolations are drilled rather than plugged to ensure a leakproof and failproof isolation. * Isolation is between stations: 01 & & & & 0 0 & & & & & * tations are numbered left to right. vailable # of stations: Parallel with s with P in the nose and T out the side must be used.... / Parallel with Isolations Manifold shown with P isolation between 1 & 2 (P), and T isolation between 2 & 3 (T). Pressure Isolation & Isolation ombinations Option code L left of isolation Option code includes both cavities Tank Isolation Option code R right of isolation & Isolation ombinations NOTE: 1) The G port is not available on a (1) station manifold. 2) The G port is not available when a pressure isolation is located between stations 1 & 2. 3) ome cavity and isolation combinations are not possible. onsult factory to determine availablity. Omit if cavity not required. ommon cavity: With solenoid clearance. --2 (P in nose) un T-162 (P in nose) ee Tech Info for valves. T...TJ Pressure Isolation Omit if P isolation not required P...PJ Tank Isolation Omit if T isolation not required & Isolation ombinations pecify when using a combination of cavity and isolation options. avities do have solenoid clearance. L R is located left of the isolation. is located right of the isolation. Two cavities, one each side of isolation.
4 02 eries Manifold eries No. of stations length inch [mm] apx. weight alum apx. weight iron [92.1] [130.2] 7 [3] [6] [168.3] ll mounting hardware is supplied. ee page 62 for itemized list. Port code mtg. Manifold mtg. #-24 UN x UN x P, [14] P 0.38 [9.7] P M IO 6H x M6 IO 6H x 16, M, T 0.6 [14] P 0.38 [9.7] P pecifications, descriptions, and dimensional data are subject to correction or change without notice or incurring obligation. ownload latest catalog page revisions at Pattern No. of tations pacing Port Threads / luminum T psi 20.7 MPa uctile Iron - 4 Electroless Nickel oated N uctile Iron - 4 Working pressure should be considered in accordance with IO 4413 to determine appropriate material type. Pattern IO NFP T ee Tech Information eries luminum 1 No. of tations uctile Iron pacing 1.0 inch 38.1 mm P NPTF NI M Port Threads P & T & E IO PP IO 1179 IO IO 6149 G M18 M14 none T PT IO 7 ee next page for available options and ordering codes.
5 - 02 eries Manifold eries with... / Omit if cavity not required ommon cavity: With solenoid clearance. --2 (P in nose) un T-162 (P in nose) ee Tech Info for valves.
42 Series. Pneumatic. Lever / Pedal Valves 4-Way, 5-Port, 2 & 3-Position. Section Q. Pneumatic
42 eries Lever / edal Valves 4-Way, -ort, 2 & -osition ection asic Valve unctions...2 42 eries asic Valve eatures... ommon art Numbers...4 odel Number Index... tacking anifold ystems...6 imensions Lever
More informationLogic Elements Screw-in Cartridge Valves Pressures to 290 bar (4200 psi) Flows to 303 l/min (80 USgpm)
Vickers artridge Valves Logic Elements Screw-in artridge Valves Pressures to 9 bar ( psi) Flows to l/min (8 USgpm) Revised 9/98 7 ontents MODEL DESRIPTION TYPIL PPLITION PRESSURE bar (psi) RTED FLOW l/min
More informationDANFLO Control Valves 400 Series Model 20
DANFLO Control Valves 400 Series Model 20 Back Pressure/Pressure Relief The DANFLO Model 20 is a pilot operated valve suitable for use in gas or liquid facilities and requires no outside power for operation.
More informationCheck Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.
Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum
More informationMedium Pressure Valves, Fittings and Tubing Pressures to 21,000 psi
Medium Pressure Valves, ittings and Tubing MXMTOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality and reliability, backed
More informationSDM to 8 sections monoblock valve D1WWDA02A
SDM 1 SDM1 1 to 8 sections monoblock valve D1WWDA2A SDM1 Additional information This folder shows the product in the most standard configurations. Please contact Sales Dpt. for more detailed information
More informationIFP C175-* REMOTE CONTROL RELIEF VALVE
IFP C175-* REMOTE CONTROL RELIEF VLVE Low Pressure Differential Quiet Operation Easy to djust Handle Three Pressure Ranges vailable Panel Mount Design P T Model Pressure Range (PSI) Rated Flow (US GPM)
More informationHow to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø
Series RM/ End lock RME Port Plug End block End block type Mounting position L Left side R Right side L side end block 0. L VVQ0000 Single unit regulator / Port plug for regulator block ø0 0 Options Note
More informationLinde Hydraulics Corporation, P.O. Box 82, Canfield, Ohio 44406
Page 1 / 5 BPV..HF with Pressure Cut-off BPV..EH with Pressure Cut-off PURPOSE The purpose of the "PRESSURE CUT-OFF" is to prevent large amounts of oil from bleeding over a relief valve, which reduces
More informationMESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL. HF and HF FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS
MESP-202H INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS HF42407-07 and HF51912-09 Muncie Power Products, Inc. TABLE OF CONTENTS DESCRIPTION PAGE Features...
More informationStandard Specifications
NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max.
More informationVickers. Flow Controls. Flow Controls FN, F(C)G, FRG. Released 6/94
Vickers Flow Controls Flow Controls FN, F(C)G, FRG Released 6/94 685 Table of Contents FN03/06/10 Model Series Application Data...............................................................................
More informationAg Leader Technology Proportional Valve
NOTE: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number Quantity Valve Assembly Open-Center 4003819 Manifold Open-Center 4003816 1 Valve Parker D3FW 4003818
More informationVSD03M DIRECTIONAL CONTROL VALVES
NFPA SIZE D03 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e.
More informationXpress L90LS Directional Control Valve. Catalog HY /UK December, 2001
Xpress L90LS Directional Control Valve Catalog HY17-8525/UK December, 2001 Catalogue HY17-8525/UK Technical Information Xpress - general information Xpress is a valve-customization service that enables
More informationEffective September, 2005 Copyright 2005 PAGE
-42 DTX Junction Boxes: Dust-Ignitionproof, Watertight Cast iron box and cover for surface mounting. Cast aluminum box and cover for surface mounting. Applications DTX dust tight and watertight boxes are
More informationVAREC 180 SERIES PRESSURE REGULATORS
Double port regulators with a variety of model options for upstream and downstream pressure control FETURES Large diaphragm and a unique double port design achieve a sensitivity of less than 5%. Set pressure
More informationPTS1120TSJB PTS2120TSTSJB
Engineering & Manufacturing Solutions Specifications: 18 gpm (68.0 lpm) Nominal Capacity. Rated up to 3000 psi (207 bar). Port Sizes: -Inlet/Outlet #12 SAE. -Work Ports #10 SAE. 10 Micron Filtration Recommended.
More informationProportional Pressure-Relief Cartridge Valve, Size 2...4
Proportional Pressure-Relief Cartridge Valve, Size... Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description proportional pressure-relief valves are direct acting
More informationPressure reducing valve, direct operated
Electric Drives and Controls Table of contents Hydraulics Pressure reducing valve, direct operated Model DR 10 DP Nominal size 10 Series 4X Maximum reduced pressure 210 bar (3050 PSI) Maximum flow 80 L/min
More informationFlow Controls. DG**-06 Series Stacking Valves. Vickers. ISO (D06) Interface Flows to 340 l/min (90 USgpm) Pressure to 210 bar (3000 psi)
Vickers Flow Controls DG**-6 Series Stacking Valves ISO-441-8 (D6) Interface Flows to 34 l/min (9 USgpm) Pressure to 21 bar (3 psi) 5125./EN/598/A Introduction These stackable modules are designed for
More informationInverse Prop. Pressure-Relief Cart., Size 2 4
Inverse Prop. Pressure-Relief Cart., Size Q max = l/min (6 gpm), p max = bar (58 psi) Direct acting, electrically operated Description inverse proportional pressure-relief valves are direct acting screw-in
More information2-way flow control valve Model 2FRM 6
R 28 6/0.98 Replaces R 28 62/05.94 R 28 6/06.98 2-way flow control valve Model 2FRM 6 Nominal size 6 Series X Maximum operating pressure 4569 SI (5 bar) ) Maximum flow 8.45 GM (2 L/min) H//D 585/97 + H//D
More informationTOP VALVE. Pat. #5,857,486 & 5,944,050. High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves. Instruction Manual
TOP VALVE Pat. #5,857,486 & 5,944,050 High Temperature: max. 300 F (149 C) Back Pressure And Pressure Relief Valves Instruction Manual PLEASE NOTE: This instruction manual provides information and instructions
More informationRegulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K
Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK
More informationRegulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K
Modular Type Regulator Series R Regulator Series R Model R M5 x.8 ccessory R2 /8, /4 R /4, 3/8 R3 /4, 3/8 R4 /4, 3/8, /2 Pages 36 through 4 Regulator with back flow mechanism Series RK R4-6 R5 R6 R2K RK,
More informationMultiple Connection Manifolds
ultiple onnection anifolds PNUAYN, IN. atalog 2400 Phone 763-559-0177 ax 763-559-0547 eatures l 2 to 10 stations l Inline anifolds, 90 anifolds, ual Air, unction locks and Terminal locks l ustom designs
More informationManual. Bypass Feeder. Installation Maintenance Repair Manual. Chemical Addition and Filtering
Manual Bypass Feeder Chemical Addition and Filtering Installation Maintenance Repair Manual Advantage Controls P.O. Box 1472 Muskogee, OK 74402 Phone: 918-686-6211 Fax: 918-686-6212 www.advantagecontrols.com
More informationTECHNICAL DATA. Q = C v P S
Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction
More informationPressure reducing valve, pilot operated, Model 3DR
RA 26 928/06.98 Pressure reducing valve, pilot operated, Model 3DR Nominal size 16 Series 5X Maximum operating pressure 3600 PSI (250 bar) Maximum flow 58.1 GPM (220 L/min) Contents Description Page Features
More informationBall valve-combinations 105 Shut-off blocks with integrated bypass and safety-lock 106 Sandwich plates 108 Accumulator safety blocks 114
able of contents Ball valve-combinations 105 hut-off blocks with integrated bypass and safety-lock 106 andwich plates 108 Accumulator safety blocks 114 with integrated 2-way ball valve type RA 114 with
More informationConcentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141
0 Operation Manual Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST 615-654-4441 sales@specialtyh2o.com 615-654-4449 fax TABLE OF CONTENTS Section 1 GENERAL 1.1 Warnings and
More informationLMU100/200 Series. Standard Specifications
Mist Spray Unit MU/ Series Intermittent spray to cutting and press gear chains, etc. Standard Specifications Inlet air Oil tank set range Oil Dynamic viscosity of oil ( C) Oil tank capacity (cm ) mbient
More informationMedium Pressure Valves, Fittings and Tubing Pressures to 22,500 psi
Medium Pressure Valves, ittings and Tubing Pressures to 22,00 psi MXMTOR has been designing and manufacturing high pressure equipment for more than thirty years and has a worldwide reputation for quality
More informationFor Low Temperature Service
42 eries Lever / edal Valves 4-Way, -ort, 2 & -osition or Low emperature ervice atalog 060- asic Valve unctions Lever Valves arallel & erpendicular Operated 2-osition, pring Return Lever arallel & erpendicular
More informationProp. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08
Prop. -Way Pressure-Reducing Cart., Size / SAE 8 Q max = 1 l/min (4 gpm), p max = bar (6 psi) Direct acting, electrically operated 1 Description proportional -way pressure-reducing cartridges are size
More informationBooster Regulator/Air Tank
Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed
More informationElectrically Operated Pressure-Relief Cartridge, Size 10
Electrically Operated Pressure-Relief Cartridge, Size 1 Q max = 14 l/min (37 gpm), p max = bar (5 psi) seated pilot stage, spool-type design, with remote contral port Z Series WUVPOC-2, WUVPLC-2 1 Description
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete
More informationStorage Systems and Accessories
Storage Systems and Accessories High Pressure Air and Inert Gases 4500-6000 PSIG DOT and ASME Cylinders High Pressure Storage Systems If an application requires storage, either in the form of a single
More informationVisual Index K4 BSP Adapters
K4 BP Adapters I 4300 atalog K4 BP Adapters 60 one BP Adapters traights HMK4 Union WMK4W4NM Bulkhead Union F6MK4 60 wivel / 60 one H6MK4 wivel Union FMK4 NPTF / 60 one F3MK4 BPT / 60 one G4MK4 / 60 one
More informationFull Range Pressure Compensating Variable Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. Rated for 3000 psi (207 bar). Weighs 7- ¾ lbs. (3.52 kg). 30-Micron Filtration Recommended. Torque to turn side lever
More informationSECTION BUTTERFLY VALVES
SECTION 15112 BUTTERFLY VALVES PART 1 GENERAL 1.01 SUMMARY A. All butterfly valves shall be of the tight closing, rubber seated type and fully comply with the latest revision of AWWA Standard C504, Class
More informationCASH VALVE CRYOGENIC CONTROLS
SH VLVE ryogenic control for pressure build regulators, pressure reducing valves, final line gas valves and combination pressure build economizer valves. Description ryogenics the science of materials
More informationSTAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL
STAND ALONE SPREADER INSTALLATION INSTRUCTIONS AND OPERATOR S MANUAL FEATURES VALVE FUNCTIONS ADJUSTMENTS SCHEMATICS Muncie Power Products, Inc. TABLE OF CONTENTS DESCRIPTION PAGE Features... 3 Hydraulic
More informationP-Series, Lightweight Hand Pumps. Exclusively from Enerpac. 70
-eries, ightweight and umps umps shown, from top to bottom: -802, -842, -202, -142 xclusively from nerpac ylinder Matching hart For help in selecting the correct hand pump for your application, please
More informationCONTINENTAL NH3 PRODUCTS PRODUCT CATALOG
PRODUCT CATALOG October 2012 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Continental NH3 Products A-360 MANIFOLD ORDERING INFORMATION Thank you for ordering our new A-360 manifold system. To assist in
More informationFOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM
IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY
More informationPower Valve: Precision Regulator. High precision, large capacity relief regulator
Power Valve: Precision Regulator Series VEX High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air
More informationDirectional Valves. Hydraulic Operated Directional Valves
Service Data Vickers Directional Valves Hydraulic Operated Directional Valves (F*) DG3V 8 (B) ** (L) (X) (*) (*) 10 (EN**) Released 04/96 5007.03/EN/0496/S DG3V-8-*(C) - (X) - 10 Spring Centered 473726
More informationCOMMERCIAL. MK Series High Performance Butterfly Valve Specifications. Hot Water, Chilled Water, Condenser Water, Steam
OMMRIL MK Series igh Performance utterfly Submittal/Technical ata ray MK Series igh Performance utterfly Valves NSI lass 150 and 300 ray ontrols ommercial ivision 13788 West Road, Suite 200 ouston, Texas
More informationFitted with a main pressure relief valve and a load check valve on every working section.
SDS18 1 to 12 sectional directional control valve Fitted with a main ressure relief valve and a load check valve on every working section. Available with arallel and series-arallel (tandem) circuit. Otional
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated
More informationBladder Accumulators. General Information. Bladder Accumulators. Introduction. Accumulator Function. Why use a Bladder Accumulator?
General Information Introduction Accumulator unction Bladder accumulators provide a means of regulating the performance of a hydraulic system. The design of the Stauff bladder accumulator makes use of
More informationSABERINDO PACIF SABERINDO PACIFIC CIFIC SABERINDO PA. A Tyco International Company
CIF A Tyco International Company 1 Foam Concentrate CIF 3% AFFF -UL Listed -UL Canada Listed 6% AFFF 6 parts AFFF concentrate to 94 parts water -UL Listed- Foam Liquid -UL Canada Listed 3% FLUOROPROTEIN
More informationTECHNICAL DATA. Q = C v P S
January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated
More informationTOP VALVE. Pat. #5,857,486 & 5,944,050. Mid-Range Pressure PSIG Back Pressure and Pressure Relief Valves. Instruction Manual
TOP VALVE Pat. #5,857,486 & 5,944,050 Mid-Range Pressure 50 232 PSIG Back Pressure and Pressure Relief Valves Instruction Manual Please Note: This instruction manual provides detailed information and instructions
More informationSandwich Valves. 1 Change in flow, temperature or fluid (SSU) rating will affect valve
Technical Information Series PRM General Description Series PRM reducing valves are used to regulate pressure, in one area of a circuit, below normal system pressure. This style valve is well suited to
More informationSeries 4 Cv= Air-Pilot operated valves. 3-way/2-position, 5-way/2-position, 5-way/3-position
3 Cv =.73-2.00 Series 4 Cv=.73-2.00 Air-Pilot operated valves Series 4: 1/8,, 3-way/2-position; 5-way/2-position; 5-way/3-position 1/2 5-way/2-position The pneumatically operated,3-way/2-position, 5-way/2-position
More informationTECHNICAL DATA. Q= Cv S
Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationTECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13
Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationSpecifications. Model VEX Operating style Fluid Proof pressure Max. operating pressure
Power Valve Regulator Valve Series 1 Large Capacity Relief Regulator 3 port large capacity poppet exhausting regulator equipped with a relief port the same size as the connection port. Specifications Model
More informationVICKERS. SystemStak Valves. ISO ; NFPA-D03; 315 bar (4500 psi); 60 L/min (15.7 USgpm) GB 2027B
VICKERS SystemStak Valves ISO 441-3; NF-D3; 315 bar (45 psi); 6 L/min (15.7 USgpm) 1 G 227 uild a Compact, Cost-Effective, Reliable Hydraulic System with Vickers SystemStak Valves Reduces System Space
More informationE 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm
Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when
More informationVertical Bladder Tanks
DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationE 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm
Return Filters E E Tank top mounting Connection up to G¼ / - SE up to l/min / 8. gpm Description pplication In the return line circuits of hydraulic systems. erformance features rotection against wear:
More informationHorizontal Bladder Tanks
DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationINSTALLATION & MAINTENANCE INSTRUCTIONS
DESCRIPTION / IDENTIFICATION The QBX series valve uses Proportion-Air closed loop technology for Pressure control. It gives an output pressure proportional to an electrical command signal input. The QB1X
More informationElectro-Pneumatic Valve Positioners
o. SS2-HEP180-0100 OVERVIEW FM Explosionproof approval Electro-Pneumatic Valve Positioners Mounted on control valves, HEP Electro-Pneumatic Valve Positioners model HEP18/19/28/29 control valve positions
More informationE 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm
Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow
More informationDigital Flow Switch. Series PFM7
Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow
More informationF68G - Olympian Plus plug-in system General purpose filter
> > Port size: /... / (ISO G/ PTF) > > Olympian Plus plug in system > > Large filter element area provides minimum pressure drop > > Effective liquid removal and positive solid particle filtration Technical
More informationCOMMERCIAL. Resilent Seated Butterfly Submittal/Technical. Technical Specifications. Application COMMERCIAL. Service
OMMRIL Resilent Seated utterfly Submittal/Technical pplication ray s NY and series resilient seated butterfly valves set the design standard for quality, reliability and long life in a wide variety of
More informationGAS VALVE RETROFIT KIT Pull Through Tube Heater Models
GAS VALVE RETROFIT KIT Pull Through Tube Heater Models DESCRIPTION: This kit is designed to replace existing Honeywell gas valves #VR8205P and #VR8205Q with White-Rodgers gas valves #36J23 and #36J58 respectively
More information131 Series. 631 Series MODEL. Schematic Diagram. Optional Features. Typical Applications. (Full Internal Port)
MODL eries (ull Internal Port) 6 eries (Reduced Internal Port) lectronic ontrol Valves Model -0/6-0 imple Proven Design Quality olenoid Pilot ontrols Ideal or D ystems Multi-unction apability; ydraulic
More informationActuators. ActuAtors. Includes NFPA Aluminum androdless, Iso/VDMA, and roundbody compact cylinders. the
Actuators ActuAtors Includes NFPA Aluminum androdless, Iso/VDMA, and roundbody compact cylinders. the Norgren Express catalog lists thepart numbers of hundreds ofconfigurations, available for rapiddelivery.
More informationAir Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.
Air Saving Valve Series R Pressure Valve Series Q Flow Valve P r.9.7 2..3.1 D -FE KE -FG -FP -FM.1.2.2.3 pressure (MPa) -D -T P ow valve Fl N AQ V e n by o i t p nsum n stroke o c r i r a Cuts g the retu
More informationInverse Proportional Pressure-Relief Cartridge, Size 10
Inverse Proportional Pressure-Relief Cartridge, Size 1 Q max = 12 l/min, p max = 3 bar Seated pilot, spool-type main stage, damped design 1 Description inverse-proportional pressure-relief valves are size
More informationGas Conversion Kits Push Through (Positive Pressure) Tube Heater Models
DESCRIPTION These kits are designed to convert from one gas type to another (eg. from NATURAL to PROPANE or from PROPANE to NATURAL) when equipped with White-Rodgers DSI gas valves number 36J23 or 36J58.
More informationBERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features
Pressure Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure Reducing Valve is a hydraulically operated,
More informationCover headline. Cover subheadline. Check Valves
Check Valves Cover headline Direct and pilot operated check valve functions for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Cover subheadline EATON Screw-In Cartridge Valves E-VLSC-MC-E December
More informationInverse Proportional Pressure-Relief Cart., Size 2 4
Inverse Proportional Pressure-Relief Cart., Size Q max = l/min, p max = 35 bar Direct acting, electrically operated Description Compact construction for cavity type AL 3/-6 UNF Operated by a proportional
More informationCooler-Bypass Thermostat Valve, Size 16
Cooler-Bypass hermostat Valve, Size Q max = l/min, p max = bar emperature-controlled, integral relief function, various pressure settings available Description emperature-dependent bypass control Integral
More informationENGINE/ PUMP ADAPTERS
ENGINE/ PUMP PTERS Hayes Manufacturing, Inc. Fife Lake, MI 9633 Phone: 23-879-3372 Fax: 23-879-330 TRNSMISSION PROUTS Fife Lake, MI 9633 Phone: 23-879-3372 Fax: 23-879-330 Table Of ontents Engine/ Mount
More informationPressure relief valve, direct operated. Type DBD. Features. Contents. RE Edition: Replaces:
Pressure relief valve, direct operated Type DBD R 2542 dition: 21-7 Replaces: 214-8 Size 3 Component series 1X Maximum operating pressure 3bar [915 psi] Maximum flow 33 l/min [87 US gpm] H5585 Features
More informationModel MTB-ASME Horizontal Bladder Tanks
DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure
More informationTEK-M ANIFOLD 7500A. Manifolds. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys ACCESSORIES
Technology Solutions TEK-M ANIFOLD 7500A Manifolds ACCESSORIES www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Tek-Manifold 7500A is available
More informationPressure Differential Automatic Manifold For LPG. PDH1000 Series. LPG Installation & Operations Instructions
Pressure Differential Automatic Manifold For LPG PDH1000 Series LPG Installation & Operations Instructions Precise Equipment Company 3822 Market St., STE 101 Denton, Texas Phone : 800.795.8388 Precise
More informationALE-32. Miniature General Purpose Regulators R07, R46 (non-repairable) Air line equipment. Technical data
ir line equipment Miniature eneral Purpose egulators 7, (non-repairable) 7 Full flow gauge ports Snap action knob locks pressure setting when pushed in Standard relieving models allow reduction of outlet
More informationR84G - Excelon Plus Modular System Pressure regulators
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Easy to read flush mounted integrated pressure gauge as
More informationPILOT OPERATED PRESSURE REDUCER VALVE - Series VR4R
PILOT OPERTED PRESSURE REDUCER VLVE - Series VR4R Veljan Pressure Reducer Valve Series VR4R are pilot operated controls used to control pressure in a secondary part of a hydraulic circuit. Pressure is
More information600 Series. Brass Ball Valves
Series Brass Ball Valves full range of economical brass ball valves intended for your common fluid control applications. vailable in standard and full port threaded, full port solder end, and full port
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More informationLV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE
LV LOADER DIRECTIONAL CONTROL VALVES INSTALLATION & USER GUIDE SPECIFICATIONS: 10 gpm (38 lpm) Nominal Capacity. Rated up to 4000 psi (275 bar). Port Sizes-Inlet/Outlet #8SAE (3/4-16). Work Ports #8SAE
More informationBERMAD Waterworks. Pressure-Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features
Pressure-Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure-Reducing Valve is a hydraulically-operated,
More informationCO2 Tank Conversion Kit P.N , P.N , and P.N
Foodservice Group Multiplex Beverage Equipment Installation Instructions for CO2 Tank Conversion Kit P.N. 002247, P.N. 0022505, and P.N. 0025099 Introduction The following instructions cover the installation
More informationSpin-On Filters SSF 24,25
Spin-On Filters SSF,5 Technical Specification Construction Die cast aluminium head Seals NBR (Buna-N ) Port connections Flow rate Working pressure Operating temperature By-pass valve Clogging indicators
More informationTECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY
Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationCASH VALVE TYPE KP BACK PRESSURE VALVES
A high capacity pilot operated back pressure valve that offers accurate control and dependable protection against overpressure conditions FEATURES Automatically maintains maximum pressure in a vessel or
More information