B-Home Round 25 B-Essential Round 50

Size: px
Start display at page:

Download "B-Home Round 25 B-Essential Round 50"

Transcription

1 Cde PELLET BURNERS B-Hme Rund 25 B-Essential Rund 50 Cde EBM / R2 INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE EN Befre installing and using the burner, read this manual carefully and keep it clse t the burner.

2 INTRODUCTION Dear Client, We wuld like t thank yu fr having chsen a B-Max appliance. The mdel chsen by yu, is a high-perfrmance prduct, with an advanced technlgical cnceptin, high reliability and excellent cnstructin quality. We advise yu t entrust the running and maintenance f this appliance t qualified prfessinals that yu knw, and als t use nly riginal spare parts when needed. This manual cntains imprtant guidelines and suggestins which shuld be cmplied with in rder t btain a simple installatin and the best pssible use f the appliance. INDEX 1 General infrmatin General warnings Restrictins Cnfrmities Structure Burner descriptin Safety devices Size Accessries Supply feed cchlea: size and weight Pellet cntainer: size and weight Technical data Operatinal wiring diagram Running Pellet Cntrl Panel Viewings n Screen User parameters 10 2 Installatin Delivery and identificatin f the prduct Identificatin Cntents f the package Handling Installatin lcatin Munting the burner Munting f the lading cchlea and the pellet cntainer Release f exhaust fumes Electrical cnnectins 13 3 Start-up Befre starting up the burner First ignitin Checks t carry ut after the first ignitin Autmatic shut-dwn and subsequent start-ups Pellet calibratin Prgramming f user parameters List f parameters Technical parameters Alarm messages Prblems - Pssible causes - Slutins 18 4 Maintenance Peridic maintenance Dispsal 20 SYMBOLS USED IN THE MANUAL AND THEIR MEANING l WARNING T indicate infrmatin abut particular details. m a f d WARNING CAUTION T indicate infrmatin abut particularly sensitive details. WARNING DANGER T indicate actins, which, if nt carried ut crrectly, can cause injuries f a generic kind r can cause malfunctins r material damage t the apparatus; s they require special attentin and prper preparatin. WARNING DANGER ELECTRICITY T indicate actins, which, if nt carried ut crrectly, can cause injuries frm electricity; s they require special attentin and prper preparatin. IT IS FORBIDDEN T indicatin actins which MUST NOT be taken. 2

3 1 GENERAL INFORMATION 1.1 General warnings l WARNING This manual is the prperty f Elmec Grup S.r.l. and its cntents may nt be cpied r passed n t third parties. All rights reserved. The appliance is nt designed t be used in envirnments with a ptentially explsive atmsphere. This manual is an integral part f the prduct; make sure that it is always kept with the appliance, even in the case f sale/transfer t anther wner, s it can be cnsulted by the user r by the staff authrised t carry ut maintenance and repairs. Read this manual thrughly befre using the appliance in rder t ensure peratinal safety. In the event f dubts cncerning the cnditins and/r wrking f the appliance r its parts, the lcal distributr shuld be cntacted fr further infrmatin. Only use riginal spare parts r nes apprved by the manufacturer in rder t avid damage t the prduct. In the event f damage t the packaging f the gds, infrm the curier and the prduct supplier f the prblem immediately. Carry ut the perating tests n the appliance and infrm the supplier f the prduct f any anmalies r running defects fund. 1.2 Restrictins d IT IS FORBIDDEN D nt use the appliance in areas with a ptentially explsive atmsphere. D nt carry ut mdificatins t the prduct withut the written authrisatin f the manufacturer. D nt pen the dr f the biler when it is in use. D nt stre inflammable materials clse t the burner, t minimise the risk f fire. D nt leave the appliance expsed t the weather. D nt install the appliance nt heat generatrs (bilers, water heaters) situated in places which are prly ventilated r are very damp. The vents in the building must be sufficiently large t guarantee cmplete cmbustin. D nt tuch the appliance with parts f the bdy which are wet, r damp and/r with bare feet. The appliance must nt be used by children r by peple wh are inexperienced. 1.3 Cnfrmities The burners B-Hme Rund 25 and B-Essential Rund 50 are in cmpliance with Eurpean directives: Machinery Directive 2006/42/CE Electrmagnetic Cmpatibility Directive 2014/30/CE Lw Vltage Directive 2014/35/CE as stated in the Cnfrmity Certificate supplied with the appliance. 3

4 1.4 Structure Cntrl Panel 2 Carter husing 3 Scket cnnectin hse 4 Biler cnnectin flange 5 Washer 6 Cmbustin chamber 7 Cnnectin fr ptinal applicatins 8 External thermstat cnnectin 9 Biler water prbe cnnectin 10 External cchlea mtr cnnectin 11 Manual pellet lading buttn 12 Fuse (3.15A delayed) 13 Main switch 14 Fuse (4A) 15 Pwer scket (230 vlts) 16 External cchlea fan pwer scket 17 Cnnectin fr use with a PC 18 Flame detectin phtcell 19 Burner safety thermstat 20 Internal cchlea gear mtr 21 Cmbustin air vent 22 Cmpressed air cmbustin kit (OPTIONAL) 23 Internal cchlea 24 Display card 25 Electrnic card V/24V transfrmer 27 Burner fan 28 Ignitin resistance 29 Fuel grill

5 1.5 Burner descriptin The burners B-Hme Rund 25 and B-Essential Rund 50 are very versatile and are able t cver a great many functins, frm installatin n new generatin bilers, bread vens and ht air generatrs t the transfrmatin f ld bilers They are made up f a rund cmbustin head, a variable-speed main ventilatr, a reliable start-up system, thanks t the flame detectin phtcell, an internal cchlea fr feeding the fuel and they are designed s a cmpressed-air self-cleaning kit can be installed. They must be cmpleted with a fuel feeding system made up f a cchlea, with a flexible tube cnnected t the burner and by a pellet cntainer, which is supplied separately, as an accessry. The burners and the whle system are managed by a cntrl panel with a micrprcessr fitted nt the device, which, as well as managing all the functins, als permits the prgramming f time bands; this is useful s the machine nly runs when it is needed. 1.6 Safety devices The burnersb-hme Rund 25 and B-Essential Rund 50 are fitted with the fllwing safety devices: Burner safety thermstat Firebreak valve (ptinal) 1.7 Size F G L C E D A B A H I M N Mdel A B C D E F G H I L M N [mm] [Ø mm] [mm] [mm] [mm] [Ø mm] [mm] [mm] [mm] [mm] [mm] [mm] Rund 25 47, , Rund 50 33,5 168, , , Accessries The fllwing accessries can be rdered separately frm the burner. They shuld be used t ensure that the burner is prperly cnnected and integrated. Mdel Cchlea (Ø 60 mm) Pellet cntainer Pellet cntainer Cmpressed air kit Cde EBL0003-P01 EBT0001-P01 EBT0002-P00 EBK0018-P00 5

6 1.8.1 Supply feed cchlea: size and weight A B C D F H E G A B C D E F G H Weight [mm] [mm] [mm] [mm] [Ø mm] [mm] [Ø mm] [mm] [Kg] Pellet cntainer: size and weight C A B Descriptin Capacity A B C Weight [Kg] [mm] [mm] [mm] [Kg] Pellet cntainer EBT0001-P Pellet cntainer EBT0002-P Technical data DESCRIPTION U/M B-Hme Rund 25 B-Essential Rund 50 Burner pwer kw Pwer supply V~Hz 230~50 230~50 Average pwer cnsumptin W Ignitin W Fuse (delayed) A Nise level dba Length f flame mm Height mm Biler cmbustin chamber minimum size Width mm Depth mm Flue draw Pa

7 1.10 Operatinal wiring diagram PM1 TE RS VCE VPC F F F 230V/50Hz N F SA FR + 24 Vdc M2 M1 ARC VPC VCE RS PM1 TE SA FR M1 M2 ARC Main cmbustin valve External cchlea fan Resistance External cchlea buttn External thermstat Water prbe Phtresistance External cchlea Internal cchlea Cmpressed air 7

8 1.11 Running The running f the appliance is cntrlled frm a cntrl panel with a micrprcessr which prgrammes the fllwing phases: When a request fr heat is sent in start-up mde the main fan, the external cchlea and the internal lading cchlea start up t supply the necessary quantity f pellets fr ignitin. The internal cchlea starts up 8 secnds later than the external cchlea; When the pellet lading fr ignitin is finished, the ignitin resistance is pwered electrically, and this ignites the flame the brightness f which is recrded by the phtcell within a max. f 20 minutes (safety time). In the event f nn-ignitin, the burner ges int SHUTDOWN mde. In the event f a SHUTDOWN, in rder t reactivate nrmal running cnditins, it is necessary t discnnect the appliance frm the mains, remve the cause f the malfunctin, and then recnnect it t the pwer supply; After the flame has been crrectly detected, the appliance starts t run nrmally with a gradual increase in pwer supply until the maximum value prgrammed is reached, and the appliance cntinues t perate in mdulatin until the prgrammed water temperature fr the biler is reached, r that f a water strage heater if ne is installed. While the burner is running, the external and internal cchleas als wrk accrding t the prgrammed ON and OFF times; Once the prgrammed temperature has been reached, the cchleas, bth internal and external, are stpped by the cntrl panel, and the pellets remaining in the cmbustin chamber cntinue t burn; When the brightness f the phtcell ges belw 20 lux, the fan speed increases t clear the cmbustin chamber f the last residue and then it stps. The burner is then ready fr the next start-up. m d WARNING CAUTION The prgramming f the parameters MUST be carried ut EXCLUSIVELY BY QUALIFIED TECHNICIANS AUTHOR- ISED BY Elmec Grup S.r.l., and nly after the Passwrd has been given. Fr the wrking and shut-dwn perids f the burner, whether the "time bands" are activated r nt shuld be taken int cnsideratin. If the COMPRESSED AIR KIT is als present, cleaning f the cmbustin chamber takes place at the beginning and at the end f each peratinal cycle f the burner. IT IS FORBIDDEN Prgramming f the technical parameters frm the User Menu Pellet The devices are designed and built t burn quality pellets which have the fllwing characteristics: Descriptin U/M Pellet Diameter mm 6 Din Plus Length mm 25 (max) Density Kg/m Lwer heating pwer kwh/kg 5 Percentage f humidity % Max 8 (f the weight) Percentage f ash % Max 1 (f the weight) 8

9 1.13 Cntrl Panel C B A D E F 1 CONTROL PANEL 2 OPERATING KEYS ( Pressure SHORT (1 secnd) Access t User Menu Pressure LONG (> 2 secnds): Check f prgrammed data Pressure LONG (> 12 secnds): Reset f all parameters. WARNING!!! With this peratin, all previus prgramming will be erased (*). NB: t exit frm the prgrammed data verificatin phase, press the key ( fr mre than 2 secnds. F Pressure SHORT (1 secnd) Mdificatin f pwer Pressure LONG (> 2 secnds): Ignitin/shut-dwn f burner ) Pressure SHORT (1 secnd) Temperature mdificatin Pressure LONG (> 2 secnds): Access t Installer's Menu. T gain access it is necessary t knw the passwrd (*). NB: t exit frm the "Installer Menu", press the key (. 3 SCREEN A Date B Burner state C Time D Parameters E Pwer cnsumed F Biler water temperature (*) Actins nly t be taken by AUTHORISED INSTALLERS Viewings n Screen Pwer Burner pwer Tk1 Lading time f external cchlea (SI) Tk2 (NOT USED) Lux Brightness intensity Ext Fan speed f external supply cchlea l WARNING At the bttm f the screen Yu can see the "Guidelines", which are useful fr the peratr. 9

10 1.14 User parameters Main display T enter "LANGUAGE" (*) T enter "TIME" (*) "TEMPERATURE" (*) "WEEKLY TIMER" (*) "HOUR FORMAT" (*) "BRIGHTNESS" (*) "TYPE OF FUEL" (*) "DATE" (*) ENABLE TIMER (*) "INFORMATION" (*) T enter burner pwer levels ( ) T enter biler water temperature (10-90 C) (*) T enter User Parameter prgramming (see paragraph "Prgramming f user parameters". 10

11 2 INSTALLATION 2.1 Delivery and identificatin f the prduct The appliances B-Max are delivered in separate packs and are placed n wden pallets Burner (1) It is supplied packed int a duplex crrugated cardbard bx. Backfire safety device (2) It is supplied packed int a duplex crrugated cardbard bx Pellet supply cchlea (3) It is supplied packed int a duplex crrugated cardbard bx and it is supplied separately frm the burner. Label (4) It is placed n the utside f the packaging fr identificatin f the prduct Identificatin The identificatin f each pack is pssible by means f the label placed n the utside f every package. l WARNING On receipt f the prduct it shuld be checked that the delivery is cmplete and in the event f any nn cnfrmities r cmplaints, the rganisatin that sld the appliance shuld be cntacted Cntents f the package Burner Burner O-ring Scket pipe Flexible hse Seal and burner supprt flange Pwer supply cable Water prbe Dcumentatin envelpe The fllwing material is supplied in the dcumentatin envelpe: Instructin manual Warranty certificate Declaratin f cnfrmity Catalgue f spare parts Bag f blts and screws Cnnectrs fr electrical cnnectins Safety anti-backfire device Firebreak valve (ptinal) Pellet supply cchlea Cchlea cmplete with: --Fan electrical cable A Delay Fuse. 2.2 Handling The burnersb-hme Rund 25 and B-Essential Rund 50 have been designed t perate slely with heat generatrs that have a vacuum cmbustin chamber, s the smke duct and the flue must be designed and realised t satisfy these requirements. The jints must be sealed and resistent t the maximum temperature levels that the fumes can reach. 11

12 2.3 Installatin lcatin The pellet burner must be installed in a place that cnfrms t current Legislatin, Regulatins and Directives against fire hazards. The psitining f the devices and the cmpnents must be rganised s that there is enugh space fr maintenance wrk, cleaning and st remval frm the burner, the biler and the flues. a WARNING DANGER The rm must have sufficient ventilatin vents which are f the right size and are psitined crrectly. 2.4 Munting the burner When munting the burner nt the biler: check that the pening (1) f the dr (2) f the biler is sufficiently large t allw the cmbustin chamber f the burner t pass thrugh it. If this is nt the case, adapt it t the diameter make fur threaded hles (3) (M8) fr fixing the burner supprt flange psitin the seal (4), supplied with the burner, between the flange (5) and the dr (2) f the biler push in the 4 screws (6) (M8) but ONLY tighten the tw screws which hld the lwer split-flange. The tw screws f the upper split-flange must ONLY BE PLACED but nt tightened. Insert the cmbustin chamber f the burner int the biler as far as is necessary tighten the tw semi-flanges with the screws (7) and the screws (6), which were previusly just placed in psitin 7 1 Rund Ø Rund 50 Ø a WARNING DANGER The burner MUST be munted ONLYin the psitin shwn in the diagram. Any ther psitin is FORBIDDEN. The flame will prpagate in a straight line, thrugh the hle f the burner cmbustin chamber. 12

13 a WARNING DANGER The munting f the burner n the biler must be sealed t avid any dangerus smke escaping. Use the seal supplied by the manufacturer. 2.5 Munting f the lading cchlea and the pellet cntainer The munting f the external lading cchlea and f the pellet cntainer is very imprtant if the burner is t run crrectly. It is advisable t buy and use the riginal accessries, because they have been specifically designed t ensure the crrect running f the burner. l WARNING The manufacturer Elmec Grup S.r.l. DOES NOT ACCEPT RESPONSIBILITY fr any damage t peple, animals r things caused by the use f cmpnents that are nt riginal. 2.6 Release f exhaust fumes The burnersb-hme Rund 25 and B-Essential Rund 50 have been designed t perate slely with heat generatrs that have a vacuum cmbustin chamber, s the smke duct and the flue must be designed and realised t satisfy these requirements. The jints must be sealed and resistent t the maximum temperature levels that the fumes can reach. a WARNING DANGER Any applicatins which are different frm the ne specified in the manual can cause fire. Nn-insulated exhaust ducts are a ptential surce f danger. It is pssible t install a flue valve which cnfrms t applicable legislatin 2.7 Electrical cnnectins The burnersb-hme Rund 25 and B-Essential Rund 50 have been wired in the factry and it is essential that nly prfessinally-qualified persnnel carry ut the wrk reprted belw Pwer supply scket (230V~50Hz) 2 External cchlea fan pwer scket 3 External cchlea mtr 4 Biler water temperature prbe 5 External thermstat cnnectin 6 Cnnectin fr use with a PC 7 Cnnectin fr ptinal applicatins f d WARNING DANGER ELECTRICITY Please remember that IS OBLIGATORY: t use an mniplar circuit breaker switch, a discnnect switch in cnfrmity with EN regulatins t use an L (phase) - N (Neutral) cnnectin t cnnect the earth t an efficient plant grunding device. The manufacturer Elmec Grup S.r.l. DECLINES ANY RESPONSIBILITY fr any damage t peple, animals r things, caused by the absence f grunding f the appliance and f the nn-cmpliance with anything specified in this manual. IT IS FORBIDDEN Use the water pipes fr the grunding f the appliance. 13

14 3 START-UP 3.1 Befre starting up the burner Befre starting up the appliance check that: the burner is crrectly munted n the biler dr and that this latter is firmly clsed the cchlea and the burner flexible cnnectin hse are psitined crrectly the pellet cntainer has been filled the water temperature prbe has been crrectly psitined the biler and the plant has been filled with water the hydraulic circuit valves are pen the fumes exhaust duct has been set up prperly. 3.2 First ignitin Cnnect the burner pwer supply, psitining the plant main switch and the main burner switch in the "ON" psitin, and check that the screen lights up. The burner has already been calibrated fr maximum pwer in the factry, s fr the first ignitin just press the F key fr abut 2 secnds and wait fr the flame t light. Leave the burner in the cntinuus running mde, at maximum pwer fr abut 15 minutes, and then with a flue gas analyser check that the values recrded are clse t the nes indicated in the table: Descriptin U/M Crrect vlaue O2 % ~ 10 CO (average) mg/cm 3 < 500 Exhaust temperature C Press the F key t turn ff the burner and leave it t cl. l WARNING This peratin must be carried ut ONLY by authrised and qualified technicians. 3.3 Checks t carry ut after the first ignitin After the first ignitin, with a cld burner: discnnect the pellet supply tube frm the burner pen the biler dr and check that n the cmbustin chamber grill THERE IS NO unburnt material. If this is nt the case, it is necessary t mdify the settings n the basis f the specific needs (the cmbustin air and the quantity f fuel) and t repeat the "FIRST IGNITION" phase previusly described. 3.4 Autmatic shut-dwn and subsequent start-ups Once the request fr heat has been satisfied, the pellet feeder stps, and the burner regulates its speed fr the burning f the residual pellet, present in the cmbustin chamber, up t the minimum luminance (20 lux) measured by the phtcell. When 20 lux is reached, the fan ges up t maximum velcity (fr 4 minutes) t clean the cmbustin chamber f any residual matter and then it turns ff. At every request fr heat all the phases described previusly are repeated. 3.5 Pellet calibratin The calibratin f the quantity f pellets necessary fr ignitin and fr running the burner is achieved as fllws: fill the pellet cntainer pull ut the flexible hse frm the burner scket and place it in a recipient (basin) Check that there are n requests fr heat Cnnect the burner pwer supply, psitining the plant main switch and the main burner switch in the "ON" psitin, and check that the screen lights up press the buttn (manual lading) until the pellets are falling cntinuusly int the recipient (the cchlea is full f pellets) empty the recipient and press the buttn again (manual lading) fr abut 6 secnds (lading time fr max pwer 5), cntrlling the time with a stpwatch, and weigh the pellets which have fallen int the basin. 14

15 Calculate the maximum burner pwer using the fllwing frmula: Y*5/45*3,6= z (kw/h) where Y Quantity f pellets (in grams) weighed in 6 secnds (lading time fr max pwer) 5 p.c.i. f the pellets 45 max. cchlea time 3,6 pellets in Kg/h. m WARNING CAUTION If the type f pellets being used is changed (nt advisable) the calibratin f the pellets MUST be repeated, because the cmbustin characteristics will change. 3.6 Prgramming f user parameters The prgramming f the user parameters can be dne fllwing the flw diagram abve, after cnnecting the burner t the mains. Main display T cnfirm selectin and g back t Main Display T enter "LANGUAGE" T cnfirm selectin T select EN - IT - ES - FR - DE T enter "TIME" View current time T prgramme r mdify time 24/03/2015 T prgramme r mdify date "HOUR FORMAT" View 12 r 24 hurs frmat T select 12 r 24 hurs "DATE" View mnth T select current mnth T cnfirm setting and t mve t day setting T prgramme r mdify current day T cnfirm setting and t mve t year setting T prgramme r mdify year "TEMPERATURE" View F r C T select F r C 15

16 "BRIGHTNESS" View brightness n display T regulate brightness levels ENABLE TIMER View peratin enabling in line with prgrammed time bands T enable peratins in line with prgrammed time bands, r nt, YES/NO "WEEKLY TIMER" View Band 1 f 7 prgrammable bands T enter prgramming f times T prgramme hur start time fr Sunday peratins T prgramme minute start time fr Sunday peratins T cnfirm setting and mve t year setting T prgramme r mdify year settings T cnfirm setting and mve t start time fr Mnday Prceed in the same way fr all the days f the week (*) T view type f fuel "TYPE OF FUEL" T select the type f fuel used used (A-B-C-D) "INFORMATION" View sftware versin T enter burner pwer levels ( ) T select the desired level T enter biler water temperature (10-90 C) T select the desired temperature (*) 1 When the Saturday times have been prgrammed, press the key F t save the prgrammed times and t prepare fr prgramming the Band 2 times 2 Press the key ) t select Band 2. Press the Key t cnfirm F and enter the level fr prgramming the start and end f running times 3 T prgramme the times, prceed as described abve 4 Repeat the same prcedure t prgramme the times f all the available time bands (up t 7) T prevent the burner wrking in a particular time band, prgramme bth the start time and the end time at

17 3.7 List f parameters Technical parameters Viewing f screen Descriptin U/M Field Factry default setting Rund 25 Rund 50 TECHNICIAN - Starting up Δ temp. - Hysteresis fr water regulatin temperature. When the set temperature is reached, the burner shuts ff. If the temperature f the hysteresis value prgrammed falls belw the set value, the burner C starts up again. Δ temp. + Maximum value the water temperature can reach beynd the set value. If the temperature exceeds the set value f the amunt selected (5 C) the burner shuts ff and nly starts up again when the C temperature prgrammed in the temperature cntrl parameter is reached " temperature ceck". External thermstat Enables the use f an external thermstat (e.g. TA r TB). On / Off Off Viewing n display h2 Enables viewing n the screen f the temperature prgrammed fr the water in the biler. On / Off On 110V / 60Hz T be activated in the cuntries with this mains vltage. YES / NO NO STARTING UP - Pwer Pellet pre-lading (s) This parameter sets the first pellet lading time. sec Cmpressed air (s) Duratin f cleaning prcess with cmpressed air. sec ,00 Initial ventilatin Fan intensity in the ingnitin phase after the "pellet pre-lading" phase ( precaric pellet ). rpm Minimum lux start-up Minimum brightness t establish a regular ignitin. Lux Lux shut-dwn If the brightness ges belw the level recrded during the time regulated within the Dead Band parameter ("Banda Mrta"), the burner shuts dwn. If this happens during nrmal running f the Lux appliance, the signal ERROR appears n the display. Dead band (s) This is the time during which the ptical sensr must cntinuusly recrd a value higher than the parameter "Minimum lux start- up" ("Lux minim avvi"). Every time the values recrded g belw the sec parameter Minimum lux start- up ("Lux minim avvi"), the cunt starts up again. Flame stabilisatin (m) Time deemed necessary fr stabilisatin f the flame, after which the burner is enabled t start up. min POWER - Cleaning Type Type f cmbustin being used. A-B-C-D A Fuel supply interval. Time between ne pellet relading and the next. Sec Start-up Filling Time frm external cchlea t start. Sec ,0 Fan Fan speed at start. rpm Pwer 1 Filling Time frm external cchlea t Pwer 1. Sec ,0 Fan Fan speed at Pwer 1. rpm Pwer 2 Filling Time frm external cchlea t Pwer 2. Sec ,5 Fan Fan speed at Pwer 2. rpm Pwer 3 Filling Time frm external cchlea t Pwer 3. Sec ,5 Fan Fan speed at Pwer 3. rpm Pwer 4 Filling Time frm external cchlea t Pwer 4. Sec ,5 Fan Fan speed at Pwer 4. rpm Pwer 5 Filling Time frm external cchlea t Pwer 5. Sec ,5 Fan Fan speed at Pwer 5. rpm NOTA The fill-up time depends n the pwer level prgrammed and n the type f fuel being used The fan speed depends n the fuel (type and quantity) and n the flue draw CLEANING - Shutting dwn The interval between the cleaning f the cmbustin grill carried Cleaning intervals (m) ut by the burner fan and the cleaning carried ut with cmpressed min air. Grill cleaning (s) Duratin f cleaning prcess with burner fan running at maximum pwer. sec Fan cleaning Fan speed during cleaning phase. rpm Cmpressed air Presence f cmpressed air kit (ptinal). YES / NO NO External fan Speed f cchlea fan. rpm SHUTTING DOWN - Test Page Duratin The time during which the ventilatr ges n running at max. pwer when the burner has been shut dwn due t an alarm ging ff. The bjective is t burn all the residual fuel left n the grill. This min cycle is activated when the burner is ff. Ventilatin Fan speed during shut-dwn phase. rpm External thermstat. This determines the peratinal mde f the burner nce the envirnment set value prgrammed has been reached. min

18 Viewing f screen Descriptin U/M Field Factry default setting Rund 25 Rund 50 TEST PAGE Resistance Start-up / Shut-dwn Ignitin resistance. ON/OFF OFF Cchlea Shut-dwn Internal cchlea. ON/OFF OFF Tank shut-dwn External cchlea. ON/OFF OFF Internal Fan Burner fan. rpm External Fan. Cchlea fan. rpm Air Start-up / Shut-dwn Activates 24V electrvalve pwer supply fr the cmpressed air kit. ON/OFF OFF Alarm Start-up / Shut-dwn Activates the 230V utput. ON/OFF OFF NOTA This checks that the main cmpnents f the burner are wrking crrectly. REMOTE CONTROL Mdule Must be activated t cnnect the GSM mdule t cnnectr 6 n the burner. YES / NO NO 3.8 Alarm messages In the event f a fault r malfunctin, the fllwing signs appear n the screen: Descriptin Failed ignitin Blackut alarm Faulty water prbe alarm Fuel finished alarm TS verheating Fuel finished 3.9 Prblems - Pssible causes - Slutins In the table belw are reprted the mst cmmn prblems with their pssible slutins. Prblem Pssible cause Slutin Failed ignitin Pwer supply absent Water prbe Fuel finished Empty pellet cntainer Discnnected r brken external cchlea cable Ignitin resistance brken Cmbustn grill is blcked Internal cchlea blcked Electrical supply t burner nt present The prbe is incrrectly psitined r cnnected Prbe faulty Pellet cntainer empty Discnnected r brken cchlea cable Cchlea mtr nt wrking Fill the cntainer Recnnect the cable r find the break Check the resistance and/r substitute it Pull ut the grill and clean it Check the internal cchlea and remve any blckages Check the mains supply Check that the electrical cables are cnnected crrectly Check that the general switches and the switches n the burner are in the crrect psitin Check its psitin and cnnectins Replace the prbe Fill the cntainer Re-establish the cnnectin Check the mtr 18

19 4 MAINTENANCE 4.1 Peridic maintenance Peridic maintenance, as well as being necessary fr the ptimal functining f the burner and the plant, is required by Law and if maintenance regulatins are nt bserved, there can be prblems r even fines. Maintenance must be entrusted t and carried ut SOLELY by qualified technicians. The pellet burners B-Hme Rund 25 and B-Essential Rund 50 have been designed t require minimal maintenance, the frequency f which depends directly n the quality and the size f the pellets used (certified r nt) and n hw the burner is regulated. f m WARNING DANGER ELECTRICITY Befre carrying ut any maintenance activity, discnnect the appliance frm the mains, and put the general switches n the plant int the OFF psitin, but als the main nes n the burner and the biler (if present). WARNING CAUTION When carrying ur maintenance, all the Persnal Safety Equipment required by current Legislatin must be used. Peridic maintenance refers t the whle plant in which the burner is installed. If nn-certified pellets are used, the indicatins belw are rendered null and vid, since the characteristics f the fuel are nt knwn. In the event f the use f nn-certified pellets, Elmec Grup S.r.l. DOES NOT ACCEPT RESPONSIBILITY fr any breakages r malfunctins r fr any pssible harm t peple, animals r things, r t the envirnment. The table is nly fr suggestin purpses and is nt binding. Fr cleaning the husing f the burner, use a damp clth with water and sap r water and methylated spirits, r with specific nn-abrasive prducts. Descriptin Peridic When necessary Weekly Six-mnthly Annual BURNER CLEANING Cmbustin chamber - ash and slag x x Burner fan x x Internal cchlea Phtcell Ignitin resistance x x Pellet cntainer Filling x x Cmbustin air suctin grill x x External cchlea bearings Pssible greasing r lubricatin x External cchlea fan x Cntrl f perishable parts x x Cntrl f cables and electrical cnnectins x x PLANT CLEANING Smke channel and flue pipe x x Inside and back part f the biler x x Cntrl f perishable parts x x Cntrl f exhaust fumes x x 19

20 m WARNING CAUTION After any maintenance wrk, checks shuld be made t ensure that the burner is perating crrectly. Use f the appliance in a pr state f maintenance culd cause unexpected and ptentially extremely dangerus malfunctins. If any parts have t be substituted, nly riginal parts shuld be used. l WARNING The manufacturer Elmec Grup S.r.l. DOES NOT ACCEPT RESPONSIBILITY fr any damage t peple, animals r things caused by the use f cmpnents that are nt riginal. Any mdificatin f r tampering with the burner will render the GUARANTEE, as well as the Manufacturer's RE- SPONSIBILITY, null and vid. 4.2 Dispsal The burner must be dispsed f, at the end f its wrking life, in line with current recycling laws; fr example, the Eurpean Directives 2002/95/CE RHS and /CE RAEE. 20

21 21

22 22

23 23

24 ELMEC GROUP S.R.L. Lc. Ca d Or Asiglian Venet (VI) ITALY Tel Fax Mail inf@b-max.cm Web

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTENT: 1. Imprtant safety instructins 2. Specificatins and main dimensins 3. Parts included 4. Cntrl bx 5. Installatin 6. Adjusting the strke length f the lift 7. Operatin mdes

More information

Instructions for use. turbomax pro 24 E 28/2 E

Instructions for use. turbomax pro 24 E 28/2 E nstructins fr use turbmax pr 4 E 8/ E GB Table f cntents; General infrmatin Table f cntents General infrmatin....................... Fr yur infrmatin........................... Key t symbls...............................

More information

Complex Care Hub Manual: High Flow Nasal Prong (HFNP) Oxygen Therapy

Complex Care Hub Manual: High Flow Nasal Prong (HFNP) Oxygen Therapy Cmplex Care Hub Manual: High Flw Nasal Prng (HFNP) Oxygen Therapy Table f Cntents 1. What is High Flw Therapy?... 2 2. Humidificatin... 2 2.1 What is humidificatin?... 2 2.2 Mechanical humidificatin...

More information

Gema s OptiColor System

Gema s OptiColor System Gema s OptiClr System The Gema OptiClr system is a simple, lw cst quick clr change slutin fr manual gun users that have multiple hppers set up t spray varius clrs. The OptiClr Manifld allws the user t

More information

MODELS. 2 & 4 Versions. SUITABLE FOR WET LOCATIONS in the following locations or unclassified locations:

MODELS. 2 & 4 Versions. SUITABLE FOR WET LOCATIONS in the following locations or unclassified locations: INSTALLATION AND MAINTENANCE MANUAL Explsin Prf Lw Prfile Linear LED Light EPL-24-50LED Series MODELS 2 & 4 Versins SUITABLE FOR WET LOCATIONS in the fllwing lcatins r unclassified lcatins: Fr Use In:

More information

Concept 305 P. Pre-installation Guide IMPORTANT!

Concept 305 P. Pre-installation Guide IMPORTANT! Pre-installatin Guide Cncept 305 P IMPORTANT! Please fllw the instructins in this guide when preparing the installatin site prir t arrival and installatin f the equipment December 8th, 2017 Editin AA,

More information

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare patient educatin prgram 4156 Suth 52 nd Street, Omaha, NE 68117 800-747-7334 402-734-6741 ChildrensOmaha.rg/HmeHealthcare We knw children CHILDREN S HOME HEALTHCARE LTV 1150 Ventilatr Instructins Yur child

More information

BaseStation 1000 Irrigation Controller Keeping a Pond or Cistern Full

BaseStation 1000 Irrigation Controller Keeping a Pond or Cistern Full BaseStatin 1000 Irrigatin Cntrller Keeping a Pnd r Cistern Full If yu have a pnd r a cistern that is fed frm an external water surce, yu can use a Baseline bisensr sil misture sensr with yur Baseline cntrller

More information

Technical Documentation

Technical Documentation Quality f the future. Technical Dcumentatin Manual Black Bx Light Order-N.: 0255-004 Sparkasse Pfrzheim Calw (BLZ 666 500 85) Kt.-Nr. 791326 UniCredit Bank AG Karlsruhe (BLZ 660 202 86) Kt.-Nr. 15653957

More information

How to Install a Toilet By See Jane DrillTM Copyright 2013, All Rights Reserved

How to Install a Toilet By See Jane DrillTM Copyright 2013, All Rights Reserved Hw t Install a Tilet By See Jane DrillTM Cpyright 2013, All Rights Reserved Objective T learn hw t remve an existing tilet and install a new tilet. The steps described in these written instructins and

More information

VOLTMAX Design Specifications

VOLTMAX Design Specifications VOLTMAX Design Specificatins Revisin 0 May 2017 The VOLTMAX line f electric bilers was develped t efficiently supply hydrnic heating systems in cmmercial, institutinal and industrial applicatins. The biler

More information

LIGHTING & POWER UNIT TYPE LPU57

LIGHTING & POWER UNIT TYPE LPU57 Title LIGHTING & POWER UNIT TYPE LPU57 USER MANUAL Dcument Number 40-374-12 Issue 03 03 DFCOM1 Added 2017.05.11 MC MC PC 02 Address and Lg Update 2017.03.23 CW CW PC 01 Original issue 2014.02.20 PC PC

More information

Installing the ACT D MAND KONTROLS Systems

Installing the ACT D MAND KONTROLS Systems Installing the ACT D MAND KONTROLS Systems Mdel C1-100-PF fr Standard Piping (Nn-recirculating) Pre-Fab Systems Installatins shall be in accrdance with the manufacturer s instructins per the requirements

More information

Content. Support Pack. Support Pack

Content. Support Pack. Support Pack Supprt Pack Supprt Pack Cntent Supprt Pack p4 High Flw Oxygen Therapy, Instructins fr use p4 AquaNASE, Fitting guide p CPAP, Instructins fr use p6 BPAP, Instructins fr use p7 V2TM Face Mask, Fitting guide

More information

PA-65-x Multi-Range Air Differential Pressure Transmitter

PA-65-x Multi-Range Air Differential Pressure Transmitter Date f Issue: 06/01/2015 Page 1 f 5 PA-65-x Multi-Range Air Differential Pressure Transmitter Features: Benefits: Field selectable multi-ranges Field selectable multi-utput Simple 5 step set-up LCD Display

More information

Lab rotation on vacuum techniques and thermal imaging

Lab rotation on vacuum techniques and thermal imaging Lab rtatin n vacuum techniques and thermal imaging Objectives Manually perate a high vacuum system thrugh pump dwn and vent rutines. Learn apprpriate vacuum system terminlgy rughing, backing, freline,

More information

Plain Language Summary

Plain Language Summary Pennsylvania Envirnmental Quality Bard New Regulatins fr Oil and Gas Well Casing and Cementing (Amendments t Chapter 78) Plain Language Summary In this dcument, the wrds rules and regulatins have the same

More information

2016 AWWA/WEA Spring Conference ACTUATORS AND VALVE TECHNOLOGY/ ACTUATOR SIZING SCOTT J. OLIVER CAROTEK, INC. APRIL 2016

2016 AWWA/WEA Spring Conference ACTUATORS AND VALVE TECHNOLOGY/ ACTUATOR SIZING SCOTT J. OLIVER CAROTEK, INC. APRIL 2016 2016 AWWA/WEA Spring Cnference ACTUATORS AND VALVE TECHNOLOGY/ ACTUATOR SIZING SCOTT J. OLIVER CAROTEK, INC. APRIL 2016 Gal Discuss in detail the art f actuatrs retrfits fr the Water/Wastewater market

More information

INSTRUCTIONS FOR USE. TURBOmax Plus 824/2 E, 828/2 E THERMOcompact 615/2 E, 620/2 E, 624/2 E, 628/2 E

INSTRUCTIONS FOR USE. TURBOmax Plus 824/2 E, 828/2 E THERMOcompact 615/2 E, 620/2 E, 624/2 E, 628/2 E NSTRUTONS FOR USE TURBOmax Plus 824/2 E, 828/2 E THERMOcmpact 65/2 E, 62/2 E, 624/2 E, 628/2 E The cde f practice fr the installatin, cmmissining & servicing f central heating systems TABLE OF ONTENTS

More information

Down and Out Mount Assembly & Installation Directions

Down and Out Mount Assembly & Installation Directions Dwn and Out Munt Assembly & Installatin Directins Munting the Dwn and Out Munt crrectly takes a lt f thught and a lt f planning. Please read the directins thrughly and plan ut hw the munt wuld be installed

More information

Management: Shop Coordinator, Shop Supervisor and Fire Safety Staff

Management: Shop Coordinator, Shop Supervisor and Fire Safety Staff FACILITIES MANAGEMENT Ht Wrk Plicy fr Wrk Perfrmed By University Emplyees 03/13/18 - Last Revisin INTENT: The intended purpse f this Plicy is t prvide a safe wrk/learning envirnment in University buildings

More information

Fume Hood User Guidelines

Fume Hood User Guidelines Fume Hd User Guidelines 1. Intrductin A fume hd cabinet is an enclsed wrking chamber fitted with an exhaust ventilatin system. The primary functin f the fume hd cabinet is t prtect individuals wrking with

More information

Nordson AP-300/600 Plasma Systems Operational Manual July 2017

Nordson AP-300/600 Plasma Systems Operational Manual July 2017 Nrdsn AP-300/600 Plasma Systems Operatinal Manual July 2017 User s Manual Page 1 A. 2.1 System Start-up T start the system first check the fllwing: 1. The pump in the back is turned n and running 2. Check

More information

Lab Pilot Fermenter Type LP351, 75 Liters OPERATING INSTRUCTIONS

Lab Pilot Fermenter Type LP351, 75 Liters OPERATING INSTRUCTIONS Lab Pilt Fermenter Type LP351, 75 Liters OPERATING INSTRUCTIONS Befre yu start... 1. Autclave antifam and base slutin (in glass bttles) alng with three feeder tubing lines with hypdermic needles attached

More information

Hydraulic accumulator cut-off and protection unit type B20

Hydraulic accumulator cut-off and protection unit type B20 Hydraulic accumulatr cut-ff and prtectin unit type B20 NS20 up t 36 a D SHEE - OERION NUL WK 491 810 07.2016 LICION Hydraulic accumulatr prtectin and cut-ff unit is used fr cnnecting hydraulic accumulatr

More information

Field Instruction. 5.2 Poles Inspection and Support Prior to Commencement of Work

Field Instruction. 5.2 Poles Inspection and Support Prior to Commencement of Work Field Instructin 5.2 Ples Inspectin and Supprt Prir t Cmmencement f Wrk Purpse This instructin utlines the minimum inspectin and supprting requirements fr wrk n ples. Safety Befre cmmencement f wrk, a

More information

Sponge-Jet Continuous VAC- Recovery System User Manual

Sponge-Jet Continuous VAC- Recovery System User Manual Spnge-Jet Spnge Blasting System Spnge-Jet Cntinuus VAC- Recvery System User Manual Mdel CVR-P110 Headquarters/Manufactured By: Spnge-Jet, Inc. (USA) 14 Pattersn Lane, Newingtn, NH 03801 1-603-610-7950

More information

WA270 Water Broom Important Safety Instructions Assembly Operation Maintenance Service Information

WA270 Water Broom Important Safety Instructions Assembly Operation Maintenance Service Information WA270 Water Brm Imprtant Safety Instructins Assembly Operatin Maintenance Service Infrmatin IMPORTANT SAFETY INSTRUCTIONS IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY

More information

Lohstr Hemer / Postfach Hemer Telefon: Fax: DEUTSCHLAND. Operating Manual.

Lohstr Hemer / Postfach Hemer Telefon: Fax: DEUTSCHLAND. Operating Manual. Lhstr. 13-58675 Hemer / Pstfach 4063-58663 Hemer Telefn: +49 2372 9274-0 Fax: +49 2372 3304 DEUTSCHLAND Operating Manual Sausage Warmer art.-n. 00-00326 + 00-00327 www.neumaerker.de 1. General Infrmatin

More information

Rev B Medivators Inc.

Rev B Medivators Inc. Site Requirements MEDIVATORS, RAPICIDE, and ADVANTAGE are registered trademarks f Medivatrs Inc. ADASPOR is a registered trademark f Medivatrs Inc. Windws is a registered trademark f Micrsft Crpratin.

More information

PULSAR ZERO Flow sensitive Unloader valve

PULSAR ZERO Flow sensitive Unloader valve Ultim aggirnament: 20/04/18 PULSAR ZERO Flw sensitive Unlader valve Technical manual: E 267 Pressure regulating valve unlader type with zer setting n delivery line: at gun clsure the water flw is bypassed

More information

Biochrom Libra S50, S60, S70 & S80. UV Visible Spectrophotometers Health & Safety Manual

Biochrom Libra S50, S60, S70 & S80. UV Visible Spectrophotometers Health & Safety Manual Bichrm Libra S50, S60, S70 & S80 UV Visible Spectrphtmeters Health & Safety Manual DECLARATION OF CONFORMITY This is t certify that the fllwing Bichrm manufactured prducts cnfrm t the requirements f the

More information

LARZEP, S.A. LARZEP AUSTRALIA PTY. LTD.

LARZEP, S.A. LARZEP AUSTRALIA PTY. LTD. HYDRAULIC PULLERS MODELS: FU0500 - FU1000 - FU2000 - FU3000 - FU5000 COMPLETE FV0500-1000-2000-3000-5000 3 JAWS PULLER FX0500-1000-2000-3000-5000 2 JAWS PULLER FT0500-1000-2000-3000-5000 GROSS BEARING

More information

MAINTENANCE, SERVICE & INSPECTION OF AIR RECEIVERS & COMPRESSORS

MAINTENANCE, SERVICE & INSPECTION OF AIR RECEIVERS & COMPRESSORS Dcument Ref: LHS2012/10 Revisin Date: 03/10/2012 Clane Business Park Clane, C. Kildare Ph: 045-868342 Fax: 045-861447 www.liftingandhandling.ie enquiries@liftingandhandling.ie MAINTENANCE, SERVICE & INSPECTION

More information

WORKSTATIONS mysite User Guide. mysite Workstation System User Guide

WORKSTATIONS mysite User Guide. mysite Workstation System User Guide Wrkstatin System Issue 1 Page 1 f 6 Sectin 1 INTRODUCTION 1.1 Intrductin Precisin s wrkstatin system ffers a fresh lk in design, functinality and perfrmance, prviding a cmplete slutin fr any ffice. Fixed

More information

Users Requirements Statement

Users Requirements Statement Mnday, March 29, 2004 http://www.prjectdevelper.cm Cntents Agreement s Purpse... 2 Applicatin s Descriptin... 2 Applicatin s Input/Output Summary... 4 Business Rules... 8 Applicatin Develpment Cmpletin

More information

UCT OPERATING MANUAL UCT POSITIVE PRESSURE MANIFOLD.

UCT OPERATING MANUAL UCT POSITIVE PRESSURE MANIFOLD. FORENSICS OPERATING MANUAL 1 2731 Bartram Rd Bristl, PA 19007 USA POSITIVE PRESSURE MANIFOLD POSITIVE PRESSURE MANIFOLD MANUAL POSITIVE PRESSURE EXTRACTION OPERATION INSTRION Thery f Operatin 2 The Psitive

More information

Europak ExeFlexx Variable Speed Booster Sets WRAS Approved Product (Approval Number )

Europak ExeFlexx Variable Speed Booster Sets WRAS Approved Product (Approval Number ) Eurpak ExeFlexx Variable Speed Bster Sets WRAS Apprved Prduct (Apprval Number 1312078) Upt 6 pumps n a single package as standard, custm build sets available Upt 480 m³/hr as standard Main Benefits: Delivered

More information

INFORMATION SHEET: OUT OF HOURS WORKING RISK ASSESSMENT AND CONTROLS

INFORMATION SHEET: OUT OF HOURS WORKING RISK ASSESSMENT AND CONTROLS INFORMATION SHEET: OUT OF HOURS WORKING RISK ASSESSMENT AND CONTROLS This Infrmatin Sheet prvides guidance n what t cnsider when undertaking an Out f Hurs Wrking risk assessment and deciding the cntrls

More information

Construction Design and Management

Construction Design and Management Cnstructin Design and Management GUIDANCE ON THE CONSTRUCTION PHASE PLAN Veritas Cnsulting Safety Services 42 Haslucks Crft, Shirley, Slihull, B90 2EQ Tel: 0121 249 1281 Mb: 07814 203 977 www.veritas-cnsulting.c.uk

More information

Opportunity for Public Participation. Plain Language Summary

Opportunity for Public Participation. Plain Language Summary Opprtunity fr Public Participatin Pennsylvania Envirnmental Quality Bard Prpsed Regulatins fr Oil and Gas Well Casing and Cementing (Amendments t Chapter 78) Plain Language Summary In this dcument, the

More information

Hot Work Policy and Procedures

Hot Work Policy and Procedures 1.0 Plicy Statement The University f New Haven has develped a ht wrk plicy and prcedure in accrdance with Occupatinal Health and Safety Administratin (OSHA) regulatins. 1.1 Purpse The University f New

More information

STIOffice Summer School Grade Setup and Entry

STIOffice Summer School Grade Setup and Entry STIOffice Summer Schl Grade Setup and Entry Exprting Students int Summer Schl Each student wh will be attending summer schl at a site ther than his/her hme schl must be exprted t the summer schl database.

More information

CONFINED SPACES SAFETY & HEALTH ISSUES AND REGULATORY COMPLIANCE

CONFINED SPACES SAFETY & HEALTH ISSUES AND REGULATORY COMPLIANCE CONFINED SPACES SAFETY & HEALTH ISSUES AND REGULATORY COMPLIANCE Are the emplyees r cntractrs wh wrk in yur facility expsed t cnfined space hazards? Have yu cnducted a thrugh assessment f yur facility

More information

Cantilever Beam Bending of Soft Tissue

Cantilever Beam Bending of Soft Tissue Cantilever Beam Bending f Sft Tissue Intrductin Cantilever beam bending is a methd used t determine the mechanical prperties f a material. It is used because it is relatively inexpensive t perfrm and gives

More information

Standard Operating Procedure

Standard Operating Procedure Standard Operating Prcedure Sectin 1 Lab Specific Infrmatin Cmpressed Gases Department: Cllege f Engineering Discvery Learning Labs Date SOP was written: 10/29/2018 Date SOP was apprved by PI/lab supervisr:

More information

Brazed Plate Heat Exchanger Operating & Instruction Manual U K Exchangers Ltd Unit 55, Stilebrook Road Olney Buckinghamshire MK46 5EA

Brazed Plate Heat Exchanger Operating & Instruction Manual U K Exchangers Ltd Unit 55, Stilebrook Road Olney Buckinghamshire MK46 5EA Brazed Plate Heat Exchanger Operating & Instructin Manual U K Exchangers Ltd Unit 55, Stilebrk Rad Olney Buckinghamshire MK46 5EA Tel: (01234) 244320 Fax: (01234) 714978 Email: sales@ukeltd.cm Web: www.uk-exchangers.cm

More information

European Roulette Game Rules

European Roulette Game Rules Eurpean Rulette Game Rules Cntents Game Overview Placing Bets Aut Adjust Bet Bet Types Payuts Favrite Bets Statistics and Billbard Game Functins Game Setting Optins Return t Player Additinal Infrmatin

More information

Slim Down and Out Swivel Mount Assembly & Installation Directions

Slim Down and Out Swivel Mount Assembly & Installation Directions Slim Dwn and Out Swivel Munt Assembly & Installatin Directins Munting the Slim Dwn and Out Swivel Munt crrectly takes a lt f thught and a lt f planning. Please read the directins thrughly and plan ut hw

More information

Weather Balloon Altitude Control System. Tim Basta, Trevor Clark, Scott Miller Date: 9/15/2014

Weather Balloon Altitude Control System. Tim Basta, Trevor Clark, Scott Miller Date: 9/15/2014 Dcument: Functinal Analysis Prject: Weather Balln Altitude Cntrl System Submitted t: Hngwei Ga Submitted by: Tim Basta, Trevr Clark, Sctt Miller Date: 9/15/2014 Intrductin The fllwing functinal specificatin

More information

SPARC Match Rules v1.2

SPARC Match Rules v1.2 SPARC Match Rules v1.2 If an event chses t use nn-standard rules they will make the alteratins clear and publicly available prir t the event. Bt Lad In and Activatin: In arenas where rbt pwer up is pssible

More information

GLASS LEVEL GAUGES with reflex or transparent glasses INSTALLATION & OPERATION MANUAL

GLASS LEVEL GAUGES with reflex or transparent glasses INSTALLATION & OPERATION MANUAL GLASS LEVEL GAUGES with reflex r transparent glasses INSTALLATION & OPERATION MANUAL 2/9 1 PARTICULARS AND PURPOSE OF INSTRUCTIONS The instructins in this manual are intended t illustrate and explain the

More information

Document Name WORK HEALTH AND SAFETY RISK MANAGEMENT POLICY AND PROCEDURE

Document Name WORK HEALTH AND SAFETY RISK MANAGEMENT POLICY AND PROCEDURE Dcument Name WORK HEALTH AND SAFETY RISK MANAGEMENT POLICY AND PROCEDURE Dcument Number PO-WHS-03 Dcument Status Authr Manager Human Resurces August 2012 Apprving Authrity Management Cmmittee August 2012

More information

URGENT MEDICAL DEVICE RECALL : /29/ C Z

URGENT MEDICAL DEVICE RECALL : /29/ C Z Custmer Cde Number: ##### Custmer Address City, State, Zip Cuntry Attentin: Risk Management Attentin: Reference: URGENT MEDICAL DEVICE RECALL March 09, 2012 Risk Management, Operating Rm Directr, Operating

More information

TDM on the Web. How To Use TDM On The Web. Below is information and instructions for using the scheduling modules in TDM

TDM on the Web. How To Use TDM On The Web. Below is information and instructions for using the scheduling modules in TDM TDM n the Web Fr 2014 turnaments, Turnament Directrs will nly be able t run turnaments using TDM n the web. As lng as there is an internet cnnectin, ne can access TDM n the web. Please nte that TDM n the

More information

Large Diameter TECTITE Installation and Specifications Manual

Large Diameter TECTITE Installation and Specifications Manual Large Diameter TECTITE Installatin and Specificatins Manual TECTITE fittings are a heat free methd fr jining Cpper, CPVC and PEX tube. TECTITE prvides a clean and easy jining methd designed t save time

More information

PRE-FILL INSPECTION OF CUSTOMER OWNED CYLINDERS

PRE-FILL INSPECTION OF CUSTOMER OWNED CYLINDERS PRE-FILL INSPECTION OF CUSTOMER OWNED CYLINDERS IGC Dc 182/13/E EUROPEAN INDUSTRIAL GASES ASSOCIATION AISBL AVENUE DES ARTS 3-5 B 1210 BRUSSELS Tel: +32 2 217 70 98 Fax: +32 2 219 85 14 E-mail: inf@eiga.eu

More information

CITY OF SACRAMENTO. Regulatory Compliance Program

CITY OF SACRAMENTO. Regulatory Compliance Program CITY OF SACRAMENTO Regulatry Cmpliance Prgram Tpic: Ergnmics Prgram Effective Date: 05/19/09 Frm: T: Human Resurces Department Risk Management Divisin Department Directrs/Divisin Managers Supersedes: 03/03

More information

First Aid Policy Version 2.0

First Aid Policy Version 2.0 First Aid Plicy Versin 2.0 Cntents Definitins Page 3 Ratinale & Scpe Page 3 Guiding Principles Page 3 Relevant Legislatin Page 3 Plicy Statements Page 4 1. Respnse t injuries and illness Page 4 2. First

More information

EDS Instruction Manual

EDS Instruction Manual EDS Instructin Manual The EDS Ultra series: "...an ultra-lightweight, quick-change, and reliable drink system, frm a quality engineering cmpany... Audi Sprt's Allan McNish Prgressive Mtrsprt Ltd Unit 10a

More information

Confined Space Entry

Confined Space Entry Cnfined Space Entry What is a Cnfined Space? A space that: Is large enugh and s cnfigured that an emplyee can enter bdily and perfrm wrk; Has limited r restricted means f entry r exit; Is nt designed fr

More information

Table of Contents. I. General Instructions. Task Information. Operator Qualification Checklist. Railroad Commission/Employer Record

Table of Contents. I. General Instructions. Task Information. Operator Qualification Checklist. Railroad Commission/Employer Record LP-Gas Student Qualifying Field Activities Installatin & Maintenance f Prpane Appliances in Recreatinal Vehicles Table f Cntents I. General Instructins II. Task Infrmatin III. Operatr Qualificatin Checklist

More information

Sponge-Jet Feed Unit User Manual

Sponge-Jet Feed Unit User Manual Spnge-Jet Spnge Blasting System Spnge-Jet Feed Unit User Manual Mdels: 100-HP 100-HP-CE 100-HP-J 200-HP 200-HP-CE Headquarters/Manufactured By: Spnge-Jet, Inc. (USA) 14 Pattersn Lane, Newingtn, NH 03801

More information

General Industry Toolbox Talks. Providing Excellence in Regulatory Compliance Management Systems

General Industry Toolbox Talks. Providing Excellence in Regulatory Compliance Management Systems General Industry Tlbx Talks Prviding Excellence in Regulatry Cmpliance Management Systems General Industry Tlbx Talks Table f Cntents Why Safety Meetings are Imprtant...- 3 - Guidelines fr Safety Training

More information

OPERATIONS CHALLENGE 2017

OPERATIONS CHALLENGE 2017 OPERATIONS CHALLENGE 2017 COLLECTION SYSTEM EVENT During the event, yur team will cmplete the fllwing: The event simulates cnnecting a 4-inch PVC lateral sewer t an existing 8-inch PVC sewer pipe while

More information

Process Safety Management Program for Contractors

Process Safety Management Program for Contractors Page 1 f 7 Sect: 1.0 Purpse This sectin cntains requirements fr Ardent (Cntract Emplyer) and ur subcntractrs fr assisting ur clients in preventing r minimizing the cnsequences f catastrphic releases f

More information

Technical Data Sheet DW1 Undercoats

Technical Data Sheet DW1 Undercoats Descriptin Wanda 8100 2K Primer ffers great filling and sanding prperties, excellent hld ut, fast dry, and gd adhesin n prperly prepared substrates. 4 Wanda 8100 2K Primer Wanda 2K Hardener Std 418.03093

More information

Pressure reducing valve. Type UZRB6

Pressure reducing valve. Type UZRB6 Pressure reducing valve type UZRB6 NS 6 up t21 MPa up t 30 DATA SHEET - OPERA RATION MANUA NUAL dm 3/min WK 424 770 03.2015 APPLICATION Pressure reducing valve fr subplate munting type UZRB6 is used t

More information

Sponge-Jet Media Recycler User Manual

Sponge-Jet Media Recycler User Manual Spnge-Jet Spnge Blasting System Spnge-Jet Media Recycler User Manual Mdel: 35P 35P-CE 50P 50P-CE Headquarters/Manufactured By: Spnge-Jet, Inc. (USA) 14 Pattersn Lane, Newingtn, NH 03801 1-603-610-7950

More information

GHISS 70, 90, 110, 125, 145, 160, 180, 200 MAX R AE

GHISS 70, 90, 110, 125, 145, 160, 180, 200 MAX R AE GHISS 70, 90, 110, 125, 145, 160, 180, 200 MAX R AE INSTRUCTIONS FOR USE AND OPERATING MANUAL STANDING GAS DEVICE WITH CAST-IRON SEGMENTED HEAT- EXCHANGER, SPARK IGNITION, IONISATION FLAME-CONTROL AND

More information

A Guide to Relocating Hazardous Materials

A Guide to Relocating Hazardous Materials A Guide t Relcating Hazardus Materials Created: March 2001 Last revisin: March 2018 TABLE OF CONTENTS Intrductin Online Resurces 3 Helpful Cntact Infrmatin 3 Planning fr the Mve Wh t Ntify f the Mve 4

More information

Ball coupling FIRG / FIRG-Q

Ball coupling FIRG / FIRG-Q Ball cupling Page 1 REVISION STATUS Issuance/revisin date Revisin index dified pages 08/11/2016 0 -- Dcument issuance dificatin descriptin Ball cupling Page 2 Smmari WARNINGS... 3 INSTRUCTIONS FOR STORAGE

More information

Description: Model Number: Robinhood Canopy RHCVI9G

Description: Model Number: Robinhood Canopy RHCVI9G Descriptin: Mdel Number: Rbinhd Canpy RHCVI9G Overview Pre-Installatin Thank yu fr purchasing a quality Rbinhd rangehd. Rbinhd has a high standard f quality cntrl and every rangehd is tested and apprved

More information

Operating Instructions

Operating Instructions DurSite & SafeSite Area Light with Battery Backup Imprtant Infrmatin: These instructins cntain safety infrmatin, read and fllw them carefully. Dialight will nt accept any respnsibility fr injury, damage

More information

Exercise 2: Reviewing the Workplace Inspection Checklist (30 min) p

Exercise 2: Reviewing the Workplace Inspection Checklist (30 min) p Exercise 2: Reviewing the Wrkplace Inspectin Checklist (30 min) p. 19-20 Part One: Behaviurs vs. Cnditins (15 min) Wrking individually: Think f 3 r 4 incidents that have ccurred r have the ptential t ccur

More information

Swim Around Lido Key Saturday, April 22, 2017 Race and Safety Plan

Swim Around Lido Key Saturday, April 22, 2017 Race and Safety Plan Swim Arund Lid Key Saturday, April 22, 2017 Race and Safety Plan This dcument utlines the details abut the race and safety plans fr ur 7-mile pen water race n Lid Key, Flrida. It cntains the fllwing: Race

More information

Technical Data Sheet EW1 Top coats

Technical Data Sheet EW1 Top coats Tp cats Descriptin Wanda PU 2K HS is a single layer Plyurethane tpcat which ffers gd pacity, high glss, quick dry and gd weather resistance. It is suitable fr repair r verall re-sprays. 4 Wanda PU 2K HS

More information

Installation Manual for VersaScreen Pro and VersaScreen IceBlaster Gutter Protection Products. Table of Contents

Installation Manual for VersaScreen Pro and VersaScreen IceBlaster Gutter Protection Products. Table of Contents Installatin Manual fr VersaScreen Pr and VersaScreen IceBlaster Gutter Prtectin Prducts Table f Cntents VersaScreen/VersaScreen Pr Installatin p. 2-4 VersaScreen IceBlaster p. 5-7 IceBlaster RE p. 5-6

More information

Recreational Sports Racquetball Rules

Recreational Sports Racquetball Rules Recreatinal Sprts Racquetball Rules Mdificatins have been made t suit BYU-Idah Recreatinal Sprts prgrams. Rule 1: Players Racquetball is an individual sprt, as such each team shall cnsist f ne (1) player.

More information

CE Marking FPC Manual For New Century Doors Limited

CE Marking FPC Manual For New Century Doors Limited Overview This manual, including the dcumentatin and recrds referenced by it, cnstitutes the Factry Prductin Cntrl (FPC) system established by NEW CENTURY DOORS LIMITED, LEIGHTON BUZZARD, BEDFORDSHIRE.

More information

SPI-SAF-40 Flammable Gas Procedure

SPI-SAF-40 Flammable Gas Procedure 1. PURPOSE This prcedure is designed t prevent flash fires r explsins frm unintentinal ignitin f an explsive mixture f flammable gas and air. 2. SCOPE This prcedure applies t Ontari Mining Operatins, where

More information

Guidelines for Handling of Nuclear Gauges

Guidelines for Handling of Nuclear Gauges Manitba STANDARD PROCEDURE INSTRUCTION Title Guidelines fr Handling f Nuclear Gauges Department Supersedes SPI Dated SPI 34-36 Effective Date Safety Health and Envirnment April 15, 2009 May 12, 2011 Guidelines

More information

Warranty & Service Information Proprietary Notice: Limited Warranty: Service Support:

Warranty & Service Information Proprietary Notice: Limited Warranty: Service Support: Operatins Manual PHI Management Inc. PO Bx 369 Prt Richey Flrida 34654 (813) 507-4429 Warranty & Service Infrmatin Prprietary Ntice: Infrmatin cntained in this dcument is cpyrighted by PHI MGMT, and may

More information

IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION Installatin Instructin English UNPACKING INSTRUCTIONS! Carefully pen the cartn, remve cntents and lay ut n cardbard r ther prtective surface t avid damage.! Check package cntents against the Supplied Parts

More information

Livermore Harley Owners Group RIDING WITH LIVERMORE HOG

Livermore Harley Owners Group RIDING WITH LIVERMORE HOG Livermre Harley Owners Grup RIDING WITH LIVERMORE HOG 2010 Riding with Livermre HOG Table f Cntents Page 1 Welcme Page 2 Ride Planning Page 2 Rad Captains Page 2 Grup Ride Basics Page 3 Grup Riding Prcedures

More information

GROVE SCHOOL BIRMINGHAM CITY COUNCIL E-SAFETY POLICY FOR SCHOOLS

GROVE SCHOOL BIRMINGHAM CITY COUNCIL E-SAFETY POLICY FOR SCHOOLS GROVE SCHOOL BIRMINGHAM CITY COUNCIL E-SAFETY POLICY FOR SCHOOLS 1. Intrductin 1.1 The gverning bdy f Grve Schl has adpted this plicy t help the schl meet its respnsibilities fr safeguarding and educating

More information

GALENA FIRE DEPARTMENT Standard Operating Guideline ICE AND WATER RESCUE. Fire Chief Signature

GALENA FIRE DEPARTMENT Standard Operating Guideline ICE AND WATER RESCUE. Fire Chief Signature Fire Chief Signature Date Effective: 01apr13 Revised: Page: 1 f 5 Purpse: T establish standards fr GFD peratins when facilitatings ice r water rescue incidents,including safety cnsideratins, respnsibility,

More information

Field Instruction. Refer to General Safety Requirements in FI 10.6 Vegetation Management Work.

Field Instruction. Refer to General Safety Requirements in FI 10.6 Vegetation Management Work. Field Instructin 10.3 Specialised Insulated Plant fr Vegetatin Management Purpse This instructin utlines the minimum requirements and safe apprach distances (SADs) fr specialised insulated plant peratrs

More information

ISOPA MDI / TDI BULK DISCHARGE & STORAGE ASSESSMENT Version February 2014

ISOPA MDI / TDI BULK DISCHARGE & STORAGE ASSESSMENT Version February 2014 Versin February 2014 The infrmatin cntained in this ISOPA MDI / TDI Bulk Discharge and Strage Assessment is believed t be accurate. ISOPA disclaims any liability in cnnectin with the use f this infrmatin

More information

175 knm Torque Tool and Calibration Unit

175 knm Torque Tool and Calibration Unit Client Lg: Tag N Pages 1 f 9 Prject Title Lcatin 175 knm Trque Tl and Calibratin Unit Depr P N NA 01 31.05.2012 Issued fr infrmatin T.L R.Ø. K.N Rev. N. Date Reasn fr Revisin Prepared Checked Apprved Vendr

More information

PLEASE REVIEW ALL INFORMATION CAREFULLY!

PLEASE REVIEW ALL INFORMATION CAREFULLY! NATIONAL TATTOO PRACTICAL EXAMINATION CANDIDATE INFORMATION BULLETIN (CIB) EXAMINATION CONTENT AND IMPORTANT ADMINISTRATION INSTRUCTIONS Please visit yur fficial examinatin prvider website OR www.nictesting.rg,

More information

Drying ovens, incubators, cooled incubators

Drying ovens, incubators, cooled incubators rying vens, incubatrs, cled incubatrs rying vens, incubatrs, cled incubatrs All the units in the ST versin are equipped with a PI micrprcessr cntrller with an LC graphic display and illuminated tuch buttns.

More information

ANNOUNCER. - If available, a script may be given to you from the Meet Director.

ANNOUNCER. - If available, a script may be given to you from the Meet Director. SCORETABLE GUIDE ANNOUNCER Yu will annunce the lifter s names as it is their turn t make their attempt and any ther annuncements needed. Yu will be in charge f the flw f the meet and t keep the spectatrs

More information

USTA Atlanta Combo Doubles Registration Information Play begins in late April

USTA Atlanta Combo Doubles Registration Information Play begins in late April Serving Cbb, Fultn, Dekalb, Gwinnett and Frsyth cunties USTA Atlanta Cmb Dubles Registratin Infrmatin Play begins in late April Spring 2011 League Infrmatin and Dates NEW! Team Match Frmat: Each team match

More information

RADWAGON OWNER S MANUAL 2016

RADWAGON OWNER S MANUAL 2016 RADWAGON OWNER S MANUAL 2016 WWW.RADPOWERBIKES.COM We are here t help! Please cntact us at INFO@RADPOWERBIKES.COM r 1-800-939-0310 if yu have questins. REV090716 Welcme Thanks yu fr purchasing the RadWagn

More information

Equipment Strategy for Post Type High Voltage Current Transformers and Metering Units

Equipment Strategy for Post Type High Voltage Current Transformers and Metering Units ASM-STR-A2281256 Versin: 2.0 Equipment Strategy fr Pst Type High Vltage Current Transfrmers and Equipment Strategy fr Pst Type High Vltage Current Transfrmers and Metering Units Current versin: 20/06/2018

More information

First Aid Policy. North Halifax Grammar School. Approved by: Principal. Date approved: November Next review: Autumn Term 2020.

First Aid Policy. North Halifax Grammar School. Approved by: Principal. Date approved: November Next review: Autumn Term 2020. Nrth Halifax Grammar Schl First Aid Plicy Apprved by: Principal Date apprved: Nvember 2017 Next review: Autumn Term 2020 Plicy wner: Schl Welfare Officer Created April 2014 General The Academy is required

More information

Come Back to Ground! 1. Introduction

Come Back to Ground! 1. Introduction Cme Back t Grund! 1. Intrductin Many ships, particularly small tugs and supply bats have used a neutral grunded distributin system fr 120 vlt single phase htel and dmestic lads. This system is identical

More information

E25 FATIGUE MANAGEMENT

E25 FATIGUE MANAGEMENT E25 FATIGUE MANAGEMENT PURPOSE AND SCOPE This Prcedure prvides the requirements and guidance needed t manage fatigue fr Laing O Rurke railway peratins. It will need t be read in cnjunctin with the rail

More information

243 Service Regulators

243 Service Regulators Regulatr Installatin and Maintenance Instructins Service Regulatrs RM-06- Rev. Intrductin The is a large capacity general-purpse gas pressure regulatr. Its utstanding perfrmance and versatility make it

More information