RESILIENT VINYL STAIR TREAD AND NOSING

Size: px
Start display at page:

Download "RESILIENT VINYL STAIR TREAD AND NOSING"

Transcription

1 THIS DOCUMENT IS INTENDED AS A SUGGESTED GUIDE FOR CREATING, MODIFYING, OR EDITING YOUR CSI FORMATTED 3-PART ARCHITECTURAL GUIDE SPECIFICATIONS. JOHNSONITE WILL NOT BE LIABLE FOR ANY DAMAGES ARISING OUT OF THE USE OF ANY INFORMATION OR SPECIFICATIONS FOUND IN THIS DOCUMENT. ENSURE THAT YOU HAVE THE LATEST PUBLICATION FOR THIS SPECIFICATION. THE SPECIFIER OR DESIGNER IS RESPONSIBLE FOR PRODUCT SELECTION AND ACCURACY OF ALL PROJECT SPECIFICATIONS, INCLUDING ANY JOHNSONITE INFORMATION OR SPECIFICATIONS USED. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general prvisins f the Cntract, including General and Supplementary Cnditins and Divisin 01 Specificatin Sectins, apply t this Sectin. 1.2 SUMMARY A. Sectin Includes: 1. Resilient Stair Tread and Nsing. 1.3 SUBMITTALS A. Prduct Data: Fr each type f prduct indicated. B. LEED Submittals: 1. Prduct Data fr Credit EQ 4.1: Fr adhesives, including printed statement f VOC cntent and chemical cmpnents. C. Samples fr Initial Selectin: Fr each type f prduct indicated. D. Samples fr Verificatin: Fr each type f prduct indicated, in manufacturer's standard-size samples f each resilient prduct clr, texture, and pattern required. Original May 2011 Page 1 f Treads, Nsings Vinyl

2 E. Prduct Schedule: Fr resilient prducts. Use same designatins indicated n Drawings. 1.4 QUALITY ASSURANCE A. Mckups: Prvide resilient prducts with mckups specified in ther Sectins. 1.5 DELIVERY, STORAGE, AND HANDLING A. Stre resilient prducts and installatin materials in dry spaces prtected frm the weather, with ambient temperatures maintained within range recmmended by Jhnsnite, but nt less than 55 deg F (13 deg C) r mre than 85 deg F (29 deg C). 1.6 PROJECT CONDITIONS A. Install resilient prducts after ther finishing peratins, including painting, have been cmpleted. B. Maintain ambient temperatures within range recmmended by Jhnsnite, but nt less than 65 deg F (18 deg C) r mre than 85 deg F (29 deg C) in spaces t receive resilient prducts during the fllwing time perids: hurs befre installatin. 2. During installatin hurs after installatin. C. Maintain the ambient relative humidity between 40% and 60% during installatin. D. Until Substantial Cmpletin, maintain ambient temperatures within range recmmended by Jhnsnite, but nt less than 55 deg F (13 deg C) r mre than 85 deg F (29 deg C). Original May 2011 Page 2 f 9

3 PART 2 - PRODUCTS 2.1 Manufacturer: Jhnsnite, Inc. Phne (800) Munn Rad (440) Chagrin Falls, Ohi Tech: Ext 9297 Web: Samples: Ext inf@jhnsnite.cm Fax: (440) ENVIRONMENTAL SUSTAINABILITY NOTES: Jhnsnite Resilient Vinyl Stair Tread and Nsing Jhnsnite ffers a RESTART reclamatin prgram fr returning unused jbsite scrap Vinyl Stair Treads cntain pre cnsumer recycle cntent 100% Recyclable SCS FlrScre Certified and meets Califrnia Specificatins Sectin Jhnsnite facilities are ISO 9001 and ISO Certified Fr all envirnmental sustainability infrmatin visit ecscrecard n Jhnsnite hme page at A. Resilient Vinyl Stair Tread: JOHNSONITE VINYL STAIR TREAD specify Vinyl Stair Tread withut riser with the fllwing physical characteristics: a. Manufactured frm a hmgeneus cmpsitin f plyvinyl chlride (PVC). b. Cmplies with requirements fr ASTM F 2169 Standard Specificatin fr Resilient Stair Treads, Type TV, Class 2, Grup 1 and 2. c. Hardness: ASTM D 2240 Nt less than 85 Shre A. d. Abrasin Resistance: ASTM D mg/cycle. e. ASTM D 2047, Standard Test Methd fr Static Cefficient f Frictin f Plish- Cated Flring f 0.6 r greater. f. ASTM E 648, Standard Test Methd fr Critical Radiant Flux f 0.45 watts/cm 2 r greater, Class I. g. Visually-Impaired treads meet ADA and are Califrnia Title 24 Accessibility requirements. Original May 2011 Page 3 f 9

4 1. Slid Clr Vinyl Stair Treads withut Riser: Fr Service Weight surface, slid clr tread withut riser, 2" height Square Nse r 1 9/16" diameter Rund Nse, tapering 5/32" t 5/64", 12" tread depth Specify (ST Specify nse [square{sq} r rund {RD}] ) Fr Safe-T-Rib surface, slid clr tread withut riser, 2" height hinged Square Nse r 1 5/8" diameter Rund Nse, tapering 1/4" t 1/8", 12 1/4" tread depth Specify (HT Specify nse [square{sq} r rund {RD}] ) Fr Heavy Duty surface, slid clr tread withut riser, 2" height hinged Square Nse, 1/4" tread thickness, 12 1/4" tread depth Specify (HD Specify nse [square{sq}] ) 2. Visually Impaired Vinyl Treads withut Riser: Fr Safe-T-Rib surface, slid clr tread withut riser, visually impaired, 2" height hinged Square Nse r 1 5/8" diameter Rund Nse, tapering 1/4 " t 1/8", 12 1/4" tread depth, with 2" wide cntrasting clr grit tape insert Specify (VIHT Specify nse [square{sq} r rund {RD}] ) Fr Safe-T-Grip surface, slid clr tread withut riser, visually impaired, 2" height hinged Square Nse, tapering 1/4 " t 1/8", 12 1/4" Tread Depth, with 2" wide cntrasting clr grit tape insert Specify (VIVG Specify nse [square{sq}] ) Fr Heavy Duty surface, slid clr tread withut riser, visually impaired, 2" height hinged Square Nse, 1/4" tread thickness, 12 1/4" tread depth with 2" wide cextruded cntrasting clr insert Specify (VIHD Specify nse [square{sq}] ) Original May 2011 Page 4 f 9

5 3. Visually Impaired Vinyl Treads withut Riser with Phtluminescent Insert: Fr Heavy Duty surface, slid clr tread withut riser, visually impaired with Phtluminescent insert, 2" height hinged Square Nse, 1/4" tread thickness, 12 1/4" tread depth with 2" wide c-extruded Phtluminescent cntrasting clr insert Specify (PVIHD Specify nse [square{sq}] Specify Phtluminescent insert clr [yellw r white] ) B. Resilient Vinyl Stair Nsing: JOHNSONITE VINYL STAIR NOSING specify Vinyl Stair Nsing with the fllwing physical characteristics: a. Manufactured frm a hmgeneus cmpsitin f plyvinyl chlride (PVC). b. Standard Stair Nsing cmplies with requirements fr ASTM F 2169 Standard Specificatin fr Resilient Stair Treads, Type TV, Class 1 and 2, Grup 1 and 2. c. Slim Line Stair Nsing cmplies with requirements fr ASTM F 2169 Standard Specificatin fr Resilient Stair Treads, Type TV, Class 2. d. Hardness: ASTM D 2240 Nt less than 85 Shre A. e. Abrasin Resistance: ASTM D mg/cycle. f. ASTM D 2047, Standard Test Methd fr Static Cefficient f Frictin f Plish- Cated Flring f 0.6 r greater. g. ASTM E 648, Standard Test Methd fr Critical Radiant Flux f 0.45 watts/cm 2 r greater, Class I. h. Square nse treads are hinged. i. Visually-Impaired treads meet ADA and are Califrnia Title 24 Accessibility requirements. 1. Flexible Slim Line Recess Nsing, Slid Clr: Fr Slim Line Recess Nsing, 1/4" material n step and riser, slid clr, visible 13/16" height hinged Square Nse, visible 1 11/32" tread, 12' length Specify (SLN specify clr by number and name A) Fr Slim Line Recess Nsing, 7/32" material n step and 1/4" material n riser, slid clr, visible 11/16" height hinged Square Nse, visible 1 11/32" tread, 12' length Specify (SLN specify clr by number and name B) Fr Slim Line Recess Nsing, 3/8" material n step and riser, slid clr, visible 1" height hinged Square Nse, visible 1 11/32" tread, 12' length Specify (SLN specify clr by number and name C) 2. Standard Vinyl Stair Nsing, Slid Clr: Fr Stair Nsing, 1/8" material butt-t n step, slid clr, 2" height hinged Square Nse r 1 1/2" diameter Rund Nse, 2 1/16" tread depth, 12' length Specify (VDL specify clr by number and name specify nse [square{sq} r rund {RD}] ) Fr Stair Nsing, 1/8" material recessed r 3/16" material butt-t n step, slid clr, 2" height hinged Square Nse, 3" ribbed tread depth, 12' length Specify (RCN specify clr by number and name B) Fr Stair Nsing, 1/8" material recessed r 3/16" material butt-t n step, slid clr, 2" height hinged Square Nse, 3" tread depth, 12' length Original May 2011 Page 5 f 9

6 Specify (SRCN specify clr by number and name B) Fr Stair Nsing, 1/4" and 5/16" material recessed n step, slid clr, 2 1/4" height hinged Square Nse, 1 15/16" tread depth, 12' length Specify (RCN specify clr by number and name A) Fr Stair Nsing, 1/4" t 5/16" material recessed n step, slid clr, 2" height hinged Square Nse, 3 1/8" tread depth, 12' length Specify (SRCN specify clr by number and name A) Fr Stair Nsing, 3/8" material recessed n step, slid clr, 2" height hinged Square Nse, 3 1/8" tread depth, 12' length Specify (SRCN specify clr by number and name C) Fr Stair Nsing, 3/8" material recessed n step and riser, slid clr, 1 1/2" height hinged Square Nse, 3 1/8" tread depth, 12' length Specify (SVCD specify clr by number and name A) Fr Stair Nsing, 1/4" and 5/16" material recessed n step and riser with ribbed surface, slid clr, 1 9/16" height hinged Square Nse, 1 5/16" tread depth, 12' length Specify (VCD specify clr by number and name ) Fr Stair Nsing, tp set fr residential, slid clr, 1 3/4" height Square Nse, 1 3/4" tread depth, 12' length Specify (DTN specify clr by number and name) 3. Visually Impaired Vinyl Stair Nsing with c-extruded cntrasting clr insert: Fr Stair Nsing, visually impaired, 1/4" t 5/16" material recessed n step, 2" height hinged Square Nse, 3 1/8" tread depth with 2" wide c-extruded cntrasting clr insert, 12' length Specify (VIRCN specify clr by number and name A) Fr Stair Nsing, visually impaired, 1/8" material recessed r 3/16" material butt-t n step, 2" height hinged Square Nse, 3" tread depth with 2" wide c-extruded cntrasting clr insert, 12' length Specify (VIRCN specify clr by number and name B) Fr Stair Nsing, visually impaired, 1/8" r 5/16" material recessed n step and riser, 2" height hinged Square Nse, 3 3/16" tread depth with 2" wide c-extruded cntrasting clr insert, 12' length Specify (VIVCD specify clr by number and name ) Fr Stair Nsing, visually impaired, tp set, 2" height hinged Square Nse, 3 3/16" tread depth with 2" wide c-extruded cntrasting clr insert, 12' length Specify (VITSN specify clr by number and name ) 4. Visually Impaired Vinyl Stair Nsing with 2" cntrasting clr grit tape insert: Fr Stair Nsing, visually impaired, 1/8" material recessed r 3/16" material butt-t n step, 2" height hinged Square Nse, 3" tread depth with 2" wide cntrasting clr grit tape insert, 12' length Specify (VIRCN specify clr by number and name B2) Original May 2011 Page 6 f 9

7 5. Visually Impaired Vinyl Stair Nsing with Phtluminescent Insert: Fr Stair Nsing, visually impaired, tp set, 2" height hinged Square Nse, 3 3/16" tread depth with 2" wide c-extruded Phtluminescent cntrasting clr insert, 12' length Specify (PVITSN specify clr by number and name A specify Phtluminescent insert clr [yellw r white] ) Fr Stair Nsing, visually impaired, 1/4" t 5/16" material recessed n step, 2" height hinged Square Nse, 3 1/8" tread depth with 2" wide c-extruded Phtluminescent cntrasting clr insert, 12' length Specify (PVIRCN specify clr by number and name A specify Phtluminescent insert clr [yellw r white] ) Fr Stair Nsing, visually impaired, 1/8" material recessed r 3/16" material butt-t n step, 2" height hinged Square Nse, 3" tread depth with 2" wide c-extruded Phtluminescent cntrasting clr insert, 12' length Specify (PVIRCN specify clr by number and name B specify Phtluminescent insert clr [yellw r white] ) Fr Stair Nsing, visually impaired, 1/8" r 5/16" material recessed n step and riser, 2" height hinged Square Nse, 3 3/16" tread depth with 2" wide c-extruded Phtluminescent cntrasting clr insert, 12' length Specify (PVIVCD specify clr by number and name specify Phtluminescent insert clr [yellw r white] ) Fr Stair Nsing, visually impaired, 1/8" material recessed r 3/16" material butt-t n step, 2" height hinged Square Nse, 3" tread depth with 2" wide Phtluminescent cntrasting clr grit tape insert, 12' length Specify (PVIRCN specify clr by number and name B2) 2.2 INSTALLATION MATERIALS A. Trwelable Leveling and Patching Cmpunds: Latex-mdified, prtland cement based frmulatin manufactured and warranted by a reputable manufacturer. B. Adhesives: as recmmended by Jhnsnite t meet site cnditins. 1. Jhnsnite #965 Flring and Tread Adhesive. 2. Jhnsnite #945 Cntact Bnd Adhesive. 3. Jhnsnite #975 Tw-Part Urethane Adhesive. 4. Jhnsnite #996 Tw-Part Epxy. C. Stair-Tread-Nse Filler: Jhnsnite #930 Tw-Part Epxy Caulking Cmpund t fill nsing substrates that d nt cnfrm t tread cnturs. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine substrates, with Installer present, fr cmpliance with requirements fr maximum misture cntent and ther cnditins affecting perfrmance f the wrk. Original May 2011 Page 7 f 9

8 B. Verify that finishes f substrates cmply with tlerances and ther requirements specified in ther Sectins and that substrates are free f cracks, ridges, depressins, scale, and freign depsits that might interfere with adhesin f resilient prducts. C. Prceed with installatin nly after unsatisfactry cnditins have been crrected. 3.2 PREPARATION A. Prepare substrates accrding t manufacturer's written instructins t ensure adhesin f resilient prducts. 1. Verify that substrates are dry and free f curing cmpunds, sealers, and hardeners. 2. Remve substrate catings and ther substances that are incmpatible with adhesives and that cntain sap, wax, il, r silicne, using mechanical methds recmmended by manufacturer. D nt use slvents. 3. Mechanically remve cntaminatin n the substrate that may cause damage t the resilient flring material. Permanent and nn-permanent markers, pens, crayns, paint, etc., must nt be used t write n the back f the flring material r used t mark the substrate as they culd bleed thrugh and stain the flring material. 4. Prepare Substrates accrding t ASTM F 710 including the fllwing: a. Misture Testing: Perfrm tests recmmended by manufacturer. Prceed with installatin nly after substrates pass testing. 1) Perfrm anhydrus calcium chlride test, ASTM F Results must nt exceed 5 lbs. Misture Vapr Emissin Rate per 1,000 sq. ft. in 24 hurs. r 2) Perfrm relative humidity test using in situ prbes, ASTM F Must nt exceed 80%. b. A ph test fr alkalinity must be cnducted. Results shuld range between 7 and 9. If the test results are nt within the acceptable range f 7 t 9, the installatin must nt prceed until the prblem has been crrected. c. Alkalinity and Adhesin Testing: Perfrm tests recmmended by manufacturer. 5. Wd steps/substrates a. The substrate must be rigid, free f mvement. b. Single wd and tngue and grve substrate shuld be cvered with 1/4" (6.4 mm) r 1/2" (13 mm) APA apprved underlayment plywd. 1) Use 1/4" (6.4 mm) thick underlayment panels fr bards with a face width f 3" (76 mm) r less. 2) Use 1/2" (76 mm) thick underlayment panels fr bards with a face width wider than 3" (76 mm). c. D nt install ver OSB (Oriented Strand Bard), particle bard, chipbard, lauan r cmpsite type underlayments. B. Fill cracks, hles, depressins and irregularities in the substrate with gd quality Prtland cement based underlayment leveling and patching cmpund and remve bumps and ridges t prduce a unifrm and smth substrate. C. Flr cvering shall nt be installed ver expansin jints. Original May 2011 Page 8 f 9

9 D. D nt install resilient prducts until they are same temperature as the space where they are t be installed. 1. Mve resilient prducts and installatin materials int spaces where they will be installed at least 48 hurs in advance f installatin. E. Sweep and vacuum clean substrates t be cvered by resilient prducts immediately befre installatin. 3.3 RESILIENT STAIR TREAD AND NOSING INSTALLATION A. Cmply with manufacturer's written instructins fr installing resilient accessries. B. Resilient Stair Tread and Nsing: 1. Use Jhnsnite #930 Epxy Caulking Cmpund t strengthen nsing and fill irregularities in substrates t cnfrm t tread nsing. 2. Tightly adhere t substrates thrughut length f each piece. 3. Fr treads installed as separate, equal-length units, install t prduce a flush jint between units. 3.4 CLEANING AND PROTECTION A. Cmply with manufacturer's written instructins fr cleaning and prtectin f resilient prducts. B. Perfrm the fllwing peratins immediately after cmpleting resilient prduct installatin: 1. Remve adhesive and ther blemishes frm expsed surfaces. 2. Sweep and vacuum surfaces thrughly. 3. Damp-mp surfaces t remve marks and sil. C. Prtect resilient prducts frm mars, marks, indentatins, and ther damage frm cnstructin peratins and placement f equipment and fixtures during remainder f cnstructin perid. D. Cver resilient prducts until Substantial Cmpletin. END OF SECTION Original May 2011 Page 9 f 9

Technical Data Sheet EW1 Top coats

Technical Data Sheet EW1 Top coats Tp cats Descriptin Wanda PU 2K HS is a single layer Plyurethane tpcat which ffers gd pacity, high glss, quick dry and gd weather resistance. It is suitable fr repair r verall re-sprays. 4 Wanda PU 2K HS

More information

PRODUCT DATA SHEET. SP550 Spray 1. USES: 2. KEY BENEFITS: DATE: MARCH 2014 COMPANY DETAILS

PRODUCT DATA SHEET. SP550 Spray 1. USES: 2. KEY BENEFITS: DATE: MARCH 2014 COMPANY DETAILS PRODUCT DATA SHEET SP550 Spray DATE: MARCH 2014 COMPANY DETAILS Cmpany Name: Rubberbnd SA 1. USES: Rubar SP550 Spray is a dual cmpnent instant-set prduct designed and manufactured fr waterprfing and surface

More information

TAL SUPERSCREED. Revision Date JUNE 2015

TAL SUPERSCREED. Revision Date JUNE 2015 DESCRIPTION is a grey single-cmpnent high-perfrmance levelling and smthing underlayment manufactured frm rapid-setting shrinkage-cmpensated cement and selected aggregates frmulated fr rectifying and smthing

More information

Wabo Crete FlexFoam Armorless closed-cell joint seal and elastomeric concrete expansion joint system

Wabo Crete FlexFoam Armorless closed-cell joint seal and elastomeric concrete expansion joint system Wab Crete FlexFam Armrless clsed-cell jint seal and elastmeric cncrete expansin jint system Features Benefits Unique Seal Prfile Designs High Perfrmance Jint Header Armrless Technlgy Versatile Mvement

More information

Technical Data Sheet DW1 Undercoats

Technical Data Sheet DW1 Undercoats Descriptin Wanda 8100 2K Primer ffers great filling and sanding prperties, excellent hld ut, fast dry, and gd adhesin n prperly prepared substrates. 4 Wanda 8100 2K Primer Wanda 2K Hardener Std 418.03093

More information

Plain Language Summary

Plain Language Summary Pennsylvania Envirnmental Quality Bard New Regulatins fr Oil and Gas Well Casing and Cementing (Amendments t Chapter 78) Plain Language Summary In this dcument, the wrds rules and regulatins have the same

More information

Instructor Guide. Counter Sinking. Flush Riveting

Instructor Guide. Counter Sinking. Flush Riveting Instructr Guide Cunter Sinking Flush Riveting Cunter Sinking Flush Riveting: Aircraft Skin Prtectin Sectin Time: 1.5 hurs Sectin Objectives: After listening t a lecture cvering the imprtance f preventing

More information

RESQ TRAINING INTERNATIONAL. Rev 0 - July 2012 USER INSTRUCTIONS. User Instructions for TED Training Emergency Dummy by RESQ-Gear.

RESQ TRAINING INTERNATIONAL. Rev 0 - July 2012 USER INSTRUCTIONS. User Instructions for TED Training Emergency Dummy by RESQ-Gear. TED Training Emergency Dummy RESQ TRAINING INTERNATIONAL Rev 0 - July 2012 USER INSTRUCTIONS User Instructins fr TED Training Emergency Dummy by RESQ-Gear.cm USER INSTRUCTIONS TED Training Emergency Dummy

More information

RESPIRATORY PROTECTION PROGRAM UW-GREEN BAY

RESPIRATORY PROTECTION PROGRAM UW-GREEN BAY UWGB Respiratry Plan RESPIRATORY PROTECTION PROGRAM UW-GREEN BAY Table f Cntents: I. Purpse II. III. IV. Prgram Administratin Wh Is Cvered Prgram Elements V. Designated Respnsibilities VI. Fit Test Prtcls

More information

AAT-272 Super Premium Sheet Vinyl Adhesive Technical Data Sheet

AAT-272 Super Premium Sheet Vinyl Adhesive Technical Data Sheet 1 AAT-272 Super Premium Sheet Vinyl Adhesive Technical Data Sheet Descriptin: AAT-272 is specially frmulated water-based adhesive designed nt nly fr the installatin f felt backed sheet vinyl but als slid

More information

Autoclear Superior 250

Autoclear Superior 250 Nrth America Technical Data Sheet S1.05.22 Descriptin A tw cmpnent VOC cmpliant clearcat, designed fr use ver Autwave. Cnsisting f ne clearcat, ne dedicated hardener and three reducers, designed fr ptimum

More information

Rev B Medivators Inc.

Rev B Medivators Inc. Site Requirements MEDIVATORS, RAPICIDE, and ADVANTAGE are registered trademarks f Medivatrs Inc. ADASPOR is a registered trademark f Medivatrs Inc. Windws is a registered trademark f Micrsft Crpratin.

More information

Autoclear Superior Pack

Autoclear Superior Pack Descriptin A 2 Pack versin f Autclear Superir 250, designed fr use ver Autwave. Cnsisting f tw clearcats and ne dedicated hardener. cvers all sizes f repairs, under all applicatin cnditins, cmbined with

More information

Technical Documentation

Technical Documentation Quality f the future. Technical Dcumentatin Manual Black Bx Light Order-N.: 0255-004 Sparkasse Pfrzheim Calw (BLZ 666 500 85) Kt.-Nr. 791326 UniCredit Bank AG Karlsruhe (BLZ 660 202 86) Kt.-Nr. 15653957

More information

Fume Hood User Guidelines

Fume Hood User Guidelines Fume Hd User Guidelines 1. Intrductin A fume hd cabinet is an enclsed wrking chamber fitted with an exhaust ventilatin system. The primary functin f the fume hd cabinet is t prtect individuals wrking with

More information

Large Diameter TECTITE Installation and Specifications Manual

Large Diameter TECTITE Installation and Specifications Manual Large Diameter TECTITE Installatin and Specificatins Manual TECTITE fittings are a heat free methd fr jining Cpper, CPVC and PEX tube. TECTITE prvides a clean and easy jining methd designed t save time

More information

Process Safety Management Program for Contractors

Process Safety Management Program for Contractors Page 1 f 7 Sect: 1.0 Purpse This sectin cntains requirements fr Ardent (Cntract Emplyer) and ur subcntractrs fr assisting ur clients in preventing r minimizing the cnsequences f catastrphic releases f

More information

MODELS. 2 & 4 Versions. SUITABLE FOR WET LOCATIONS in the following locations or unclassified locations:

MODELS. 2 & 4 Versions. SUITABLE FOR WET LOCATIONS in the following locations or unclassified locations: INSTALLATION AND MAINTENANCE MANUAL Explsin Prf Lw Prfile Linear LED Light EPL-24-50LED Series MODELS 2 & 4 Versins SUITABLE FOR WET LOCATIONS in the fllwing lcatins r unclassified lcatins: Fr Use In:

More information

Management: Shop Coordinator, Shop Supervisor and Fire Safety Staff

Management: Shop Coordinator, Shop Supervisor and Fire Safety Staff FACILITIES MANAGEMENT Ht Wrk Plicy fr Wrk Perfrmed By University Emplyees 03/13/18 - Last Revisin INTENT: The intended purpse f this Plicy is t prvide a safe wrk/learning envirnment in University buildings

More information

Document Name WORK HEALTH AND SAFETY RISK MANAGEMENT POLICY AND PROCEDURE

Document Name WORK HEALTH AND SAFETY RISK MANAGEMENT POLICY AND PROCEDURE Dcument Name WORK HEALTH AND SAFETY RISK MANAGEMENT POLICY AND PROCEDURE Dcument Number PO-WHS-03 Dcument Status Authr Manager Human Resurces August 2012 Apprving Authrity Management Cmmittee August 2012

More information

Cleaning & Maintenance Advice Ordinary Glass Clear, Toned and Super Toned.

Cleaning & Maintenance Advice Ordinary Glass Clear, Toned and Super Toned. Cleaning & Maintenance Advice Ordinary Glass Clear, Tned and Super Tned. Viridian VFlat Viridian VLam Viridian IntruderGuard Viridian AssaultGuard Viridian VTugh Viridian VLam Hush Viridian LuminaClud

More information

Effective Date: 14-Feb-2017 SLING SAFETY GUIDELINES. Table of Contents

Effective Date: 14-Feb-2017 SLING SAFETY GUIDELINES. Table of Contents Versin: 2 Page: 1 f 7 Table f Cntents 1.0 Intrductin... 2 1.1 Purpse... 2 1.2 Scpe... 2 1.3 Definitins... 2 1.4 Training Requirements... 3 1.5 Persn Prtective Equipment (PPE) Requirements... 3 2.0 General

More information

WA270 Water Broom Important Safety Instructions Assembly Operation Maintenance Service Information

WA270 Water Broom Important Safety Instructions Assembly Operation Maintenance Service Information WA270 Water Brm Imprtant Safety Instructins Assembly Operatin Maintenance Service Infrmatin IMPORTANT SAFETY INSTRUCTIONS IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY

More information

Impact resistance of fiberboard shipping containers

Impact resistance of fiberboard shipping containers T 801 m-94 SUGGESTED METHOD 1944 OFFICIAL STANDARD 1971 OFFICIAL TEST METHOD 1983 REVISED 1988 1994 TAPPI The infrmatin and data cntained in this dcument were prepared by a technical cmmittee f the Assciatin.

More information

Material Safety Data Sheet " Paving Grade Bitumen"

Material Safety Data Sheet  Paving Grade Bitumen Material Safety Data Sheet Page 1 f 6 Sectin 1 : Prduct and Cmpany Identificatin Prduct Name: Supplier: 40-50, 60-70, 80-100 and ther Penetratin Grade Bitumen MTA Updated: 26 April 2016 CAS Number: Mixture

More information

CITY OF SACRAMENTO. Regulatory Compliance Program

CITY OF SACRAMENTO. Regulatory Compliance Program CITY OF SACRAMENTO Regulatry Cmpliance Prgram Tpic: Ergnmics Prgram Effective Date: 05/19/09 Frm: T: Human Resurces Department Risk Management Divisin Department Directrs/Divisin Managers Supersedes: 03/03

More information

Instructions for use. turbomax pro 24 E 28/2 E

Instructions for use. turbomax pro 24 E 28/2 E nstructins fr use turbmax pr 4 E 8/ E GB Table f cntents; General infrmatin Table f cntents General infrmatin....................... Fr yur infrmatin........................... Key t symbls...............................

More information

BURNINGTREE STUMPS WITH

BURNINGTREE STUMPS WITH r"2.0.1 'Tf~G If: (),7QS p, /\( X CI'RCULA," BURNINGTREE STUMPS WITH, I en i z ;; CI:: en z ~ en Z t >< THOUSANDS OF ELM TREES in Illinis have been killed by disease in the last ten years. Many f these

More information

Installation Manual for VersaScreen Pro and VersaScreen IceBlaster Gutter Protection Products. Table of Contents

Installation Manual for VersaScreen Pro and VersaScreen IceBlaster Gutter Protection Products. Table of Contents Installatin Manual fr VersaScreen Pr and VersaScreen IceBlaster Gutter Prtectin Prducts Table f Cntents VersaScreen/VersaScreen Pr Installatin p. 2-4 VersaScreen IceBlaster p. 5-7 IceBlaster RE p. 5-6

More information

Description: Model Number: Robinhood Canopy RHCVI9G

Description: Model Number: Robinhood Canopy RHCVI9G Descriptin: Mdel Number: Rbinhd Canpy RHCVI9G Overview Pre-Installatin Thank yu fr purchasing a quality Rbinhd rangehd. Rbinhd has a high standard f quality cntrl and every rangehd is tested and apprved

More information

WORKSTATIONS mysite User Guide. mysite Workstation System User Guide

WORKSTATIONS mysite User Guide. mysite Workstation System User Guide Wrkstatin System Issue 1 Page 1 f 6 Sectin 1 INTRODUCTION 1.1 Intrductin Precisin s wrkstatin system ffers a fresh lk in design, functinality and perfrmance, prviding a cmplete slutin fr any ffice. Fixed

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTENT: 1. Imprtant safety instructins 2. Specificatins and main dimensins 3. Parts included 4. Cntrl bx 5. Installatin 6. Adjusting the strke length f the lift 7. Operatin mdes

More information

Disinfection and decontamination

Disinfection and decontamination Revisin histry Versin Date issued Amendment Details 1.0 5 Dec 2013 All 2.0 1 Dec 2015 All Sectin(s) Details Refrmatted frm Appendix 3 f PLANTPLAN (V1.0 Nv 2011). Original dcument separated int tw Guidelines.

More information

Concept 305 P. Pre-installation Guide IMPORTANT!

Concept 305 P. Pre-installation Guide IMPORTANT! Pre-installatin Guide Cncept 305 P IMPORTANT! Please fllw the instructins in this guide when preparing the installatin site prir t arrival and installatin f the equipment December 8th, 2017 Editin AA,

More information

CONFINED SPACES SAFETY & HEALTH ISSUES AND REGULATORY COMPLIANCE

CONFINED SPACES SAFETY & HEALTH ISSUES AND REGULATORY COMPLIANCE CONFINED SPACES SAFETY & HEALTH ISSUES AND REGULATORY COMPLIANCE Are the emplyees r cntractrs wh wrk in yur facility expsed t cnfined space hazards? Have yu cnducted a thrugh assessment f yur facility

More information

Kennecott Utah Copper Corporation Safety and Health Standards

Kennecott Utah Copper Corporation Safety and Health Standards Revisin N. 3 07/2004 Page 1 f 5 Kennectt Utah Cpper Crpratin Safety and Health Standards Standard N.: 16.7 Scafflding 16.7.1 INTRODUCTION 16.7.1.1 The purpse f this standard is t define specific requirements

More information

Users Requirements Statement

Users Requirements Statement Mnday, March 29, 2004 http://www.prjectdevelper.cm Cntents Agreement s Purpse... 2 Applicatin s Descriptin... 2 Applicatin s Input/Output Summary... 4 Business Rules... 8 Applicatin Develpment Cmpletin

More information

A Guide to Relocating Hazardous Materials

A Guide to Relocating Hazardous Materials A Guide t Relcating Hazardus Materials Created: March 2001 Last revisin: March 2018 TABLE OF CONTENTS Intrductin Online Resurces 3 Helpful Cntact Infrmatin 3 Planning fr the Mve Wh t Ntify f the Mve 4

More information

TECHNICAL INFORMATION MANUAL Sika CarboDur Near Surface Mounted Reinforcement

TECHNICAL INFORMATION MANUAL Sika CarboDur Near Surface Mounted Reinforcement Sika CarbDur Near Surface Munted Reinfrcement TABLE OF CONTENTS 1 Intrductin 3 2 System Descriptin 3 2.1 References 3 2.2 Limitatins 3 3 Prducts 4 3.1 Material Strage 4 4 Equipment 5 4.1 Tls 5 4.2 Cleaning

More information

Field Instruction. 5.2 Poles Inspection and Support Prior to Commencement of Work

Field Instruction. 5.2 Poles Inspection and Support Prior to Commencement of Work Field Instructin 5.2 Ples Inspectin and Supprt Prir t Cmmencement f Wrk Purpse This instructin utlines the minimum inspectin and supprting requirements fr wrk n ples. Safety Befre cmmencement f wrk, a

More information

Public School Choice EBR Guidance. North Banks Middle School

Public School Choice EBR Guidance. North Banks Middle School Public Schl Chice EBR Guidance Nrth Banks Middle Schl East Batn Ruge Parish Schl System Federal Prgrams, Title I Instructinal Resurce Center 1022 S. Fster Drive Batn Ruge, Luisiana 70806 Bernard Taylr,

More information

Modified ISL Playing Rules

Modified ISL Playing Rules Mdified ISL Playing Rules Althugh all FIFA Laws f the games will be applied during the games, belw are specific laws that have been mdified fr use in yuth league games. T differentiate between the FIFA

More information

ADDITIONAL SOURCES OF INFORMATION ARE:

ADDITIONAL SOURCES OF INFORMATION ARE: PREFACE The infrmatin n plicies and prcedures is intended fr the use f Texas Tech University Department f Intercllegiate Athletics. The manual supplements the Texas Tech University Operating Plicies and

More information

Construction Design and Management

Construction Design and Management Cnstructin Design and Management GUIDANCE ON THE CONSTRUCTION PHASE PLAN Veritas Cnsulting Safety Services 42 Haslucks Crft, Shirley, Slihull, B90 2EQ Tel: 0121 249 1281 Mb: 07814 203 977 www.veritas-cnsulting.c.uk

More information

Modified ISL Playing Rules

Modified ISL Playing Rules Mdified ISL Playing Rules Althugh all FIFA Laws f the games will be applied during the games, belw are specific laws that have been mdified fr use in yuth league games. T differentiate between the FIFA

More information

Table of Contents. I. General Instructions. Task Information. Operator Qualification Checklist. Railroad Commission/Employer Record

Table of Contents. I. General Instructions. Task Information. Operator Qualification Checklist. Railroad Commission/Employer Record LP-Gas Student Qualifying Field Activities Installatin & Maintenance f Prpane Appliances in Recreatinal Vehicles Table f Cntents I. General Instructins II. Task Infrmatin III. Operatr Qualificatin Checklist

More information

DUST CONTROL. The hazard is likely to cause death or serious physical harm; and. There is a feasible and useful method to correct the hazard.

DUST CONTROL. The hazard is likely to cause death or serious physical harm; and. There is a feasible and useful method to correct the hazard. DUST CONTROL OSHA has cmmenced rulemaking t develp a cmbustible dust standard fr general industry. Cmbustible dust can cause catastrphic explsins like the 2008 disaster at a sugar refinery that killed

More information

Hot Work Policy and Procedures

Hot Work Policy and Procedures 1.0 Plicy Statement The University f New Haven has develped a ht wrk plicy and prcedure in accrdance with Occupatinal Health and Safety Administratin (OSHA) regulatins. 1.1 Purpse The University f New

More information

Data Sheet CI-IB-DS Insulation Board. with ECOSE Technology

Data Sheet CI-IB-DS Insulation Board. with ECOSE Technology Data Sheet CI-IB-DS 06-15 Insulatin Bard with ECOSE Technlgy Insulatin Bard with ECOSE Technlgy Descriptin Knauf Insulatin Insulatin Bard is a thermal and acustical insulatin prduct bnded with ECOSE Technlgy.

More information

Standard Operating Procedure

Standard Operating Procedure Standard Operating Prcedure Sectin 1 Lab Specific Infrmatin Cmpressed Gases Department: Cllege f Engineering Discvery Learning Labs Date SOP was written: 10/29/2018 Date SOP was apprved by PI/lab supervisr:

More information

Sponge-Jet Media Recycler User Manual

Sponge-Jet Media Recycler User Manual Spnge-Jet Spnge Blasting System Spnge-Jet Media Recycler User Manual Mdel: 35P 35P-CE 50P 50P-CE Headquarters/Manufactured By: Spnge-Jet, Inc. (USA) 14 Pattersn Lane, Newingtn, NH 03801 1-603-610-7950

More information

243 Service Regulators

243 Service Regulators Regulatr Installatin and Maintenance Instructins Service Regulatrs RM-06- Rev. Intrductin The is a large capacity general-purpse gas pressure regulatr. Its utstanding perfrmance and versatility make it

More information

Safe Storage of Hazardous Chemicals

Safe Storage of Hazardous Chemicals Safe Strage f Hazardus Chemicals Brunswick Crèche and Day Nursery aims t prvide a safe envirnment where chemicals and hazardus equipment are safely stred and managed away, that pses n risk t the health

More information

How to Install a Toilet By See Jane DrillTM Copyright 2013, All Rights Reserved

How to Install a Toilet By See Jane DrillTM Copyright 2013, All Rights Reserved Hw t Install a Tilet By See Jane DrillTM Cpyright 2013, All Rights Reserved Objective T learn hw t remve an existing tilet and install a new tilet. The steps described in these written instructins and

More information

OPERATIONS CHALLENGE 2017

OPERATIONS CHALLENGE 2017 OPERATIONS CHALLENGE 2017 COLLECTION SYSTEM EVENT During the event, yur team will cmplete the fllwing: The event simulates cnnecting a 4-inch PVC lateral sewer t an existing 8-inch PVC sewer pipe while

More information

SowBridge Proper Management and Maintenance of Cool Cells

SowBridge Proper Management and Maintenance of Cool Cells Breeding Herd Educatin Series 2011-12 Timely, relevant & cnvenient learning Thank yu fr participating in SwBridge 2011-12. T start this presentatin, advance ne slide by pressing enter r the dwn r right

More information

URGENT MEDICAL DEVICE RECALL : /29/ C Z

URGENT MEDICAL DEVICE RECALL : /29/ C Z Custmer Cde Number: ##### Custmer Address City, State, Zip Cuntry Attentin: Risk Management Attentin: Reference: URGENT MEDICAL DEVICE RECALL March 09, 2012 Risk Management, Operating Rm Directr, Operating

More information

Tank Cleanliness Standards

Tank Cleanliness Standards Tank Cleanliness Standards FOR CHEMICAL TANKERS Histry First published in 2011 Created t simplify the tank cleanliness verificatin prcess as well as t reduce the need fr in-tank inspectins Reductin f the

More information

WCSC Walnut Tournament 2018

WCSC Walnut Tournament 2018 Turnament Headquarters Heather Farms 1 (HF1) will serve as the Primary Turnament Headquarters. Turnament standings and any ther annuncements pertinent t the turnament will be psted at an infrmatin area

More information

Down and Out Mount Assembly & Installation Directions

Down and Out Mount Assembly & Installation Directions Dwn and Out Munt Assembly & Installatin Directins Munting the Dwn and Out Munt crrectly takes a lt f thught and a lt f planning. Please read the directins thrughly and plan ut hw the munt wuld be installed

More information

GROVE SCHOOL BIRMINGHAM CITY COUNCIL E-SAFETY POLICY FOR SCHOOLS

GROVE SCHOOL BIRMINGHAM CITY COUNCIL E-SAFETY POLICY FOR SCHOOLS GROVE SCHOOL BIRMINGHAM CITY COUNCIL E-SAFETY POLICY FOR SCHOOLS 1. Intrductin 1.1 The gverning bdy f Grve Schl has adpted this plicy t help the schl meet its respnsibilities fr safeguarding and educating

More information

All Students MUST fly with the assistance of a Club approved Instructor until such time as he/she has passed his/her Wings Test.

All Students MUST fly with the assistance of a Club approved Instructor until such time as he/she has passed his/her Wings Test. 6 th Divisin Flyers/Orillia Aermdelers Wings Prgram The 6 th Divisin Flyers/Orillia Aermdelers Wings Prgram is an Instructin prgram with tried and prven methds f teaching newcmers t the hbby/sprt f aer

More information

Opportunity for Public Participation. Plain Language Summary

Opportunity for Public Participation. Plain Language Summary Opprtunity fr Public Participatin Pennsylvania Envirnmental Quality Bard Prpsed Regulatins fr Oil and Gas Well Casing and Cementing (Amendments t Chapter 78) Plain Language Summary In this dcument, the

More information

TUTORIAL TB 194

TUTORIAL TB 194 TUTORIAL 21.17 TB 194 Technieken vr cnstructie, leggen en installatie van kabelsystemen 194 Cnstructin, Laying and Installatin techniques Peter van Velzen Engineering Julz Cigre B1-NL Wrking grup 21.17

More information

Confined Space Entry

Confined Space Entry Cnfined Space Entry What is a Cnfined Space? A space that: Is large enugh and s cnfigured that an emplyee can enter bdily and perfrm wrk; Has limited r restricted means f entry r exit; Is nt designed fr

More information

Equipment Strategy for Post Type High Voltage Current Transformers and Metering Units

Equipment Strategy for Post Type High Voltage Current Transformers and Metering Units ASM-STR-A2281256 Versin: 2.0 Equipment Strategy fr Pst Type High Vltage Current Transfrmers and Equipment Strategy fr Pst Type High Vltage Current Transfrmers and Metering Units Current versin: 20/06/2018

More information

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare

patient education program 4156 South 52 nd Street, Omaha, NE ChildrensOmaha.org/HomeHealthcare patient educatin prgram 4156 Suth 52 nd Street, Omaha, NE 68117 800-747-7334 402-734-6741 ChildrensOmaha.rg/HmeHealthcare We knw children CHILDREN S HOME HEALTHCARE LTV 1150 Ventilatr Instructins Yur child

More information

Safety Folder Quick Start Guide

Safety Folder Quick Start Guide Safety Flder Quick Start Guide Intrductin Hw Hw Where t Safety Management Systems t get started the system will help yu cmply with the law and hw t get help Safety Flder Intrductin t Safety Management

More information

Feet. Magdalen Court School

Feet. Magdalen Court School Magdalen Curt Schl Feet These are the vain f sme f my walkers, yu can eliminate r reduce the severity & number f blisters, in the wrse cases I've seen feet falling t bits n Ten Trs, hrrific & unnecessary.

More information

PRE-FILL INSPECTION OF CUSTOMER OWNED CYLINDERS

PRE-FILL INSPECTION OF CUSTOMER OWNED CYLINDERS PRE-FILL INSPECTION OF CUSTOMER OWNED CYLINDERS IGC Dc 182/13/E EUROPEAN INDUSTRIAL GASES ASSOCIATION AISBL AVENUE DES ARTS 3-5 B 1210 BRUSSELS Tel: +32 2 217 70 98 Fax: +32 2 219 85 14 E-mail: inf@eiga.eu

More information

GALENA FIRE DEPARTMENT Standard Operating Guideline ICE AND WATER RESCUE. Fire Chief Signature

GALENA FIRE DEPARTMENT Standard Operating Guideline ICE AND WATER RESCUE. Fire Chief Signature Fire Chief Signature Date Effective: 01apr13 Revised: Page: 1 f 5 Purpse: T establish standards fr GFD peratins when facilitatings ice r water rescue incidents,including safety cnsideratins, respnsibility,

More information

LIFESAVING AWARDS KINDS OF AWARDS. Given for saving life or attempting to save life without risk to the candidate s own life.

LIFESAVING AWARDS KINDS OF AWARDS. Given for saving life or attempting to save life without risk to the candidate s own life. LIFESAVING AWARDS Part f the Girl Scut prgram since the beginning f the mvement in the United States, Lifesaving Awards are natinal awards given t a registered Girl Scut wh has saved r attempted t save

More information

Who s Your School Breakfast Star? Writing Contest Official Rules

Who s Your School Breakfast Star? Writing Contest Official Rules Wh s Yur Schl Breakfast Star? Writing Cntest Official Rules Abut the Writing Cntest As part f SNA s Natinal Schl Breakfast Week 2013, students will have the pprtunity write abut a special breakfast with

More information

MATERIAL SAFETY DATA SHEET FOR ANCHOR WINE BACTERIA

MATERIAL SAFETY DATA SHEET FOR ANCHOR WINE BACTERIA Rymc (Pty) Ltd, Registratin N. 2001/016795/07 22 Bunsen Street, Industria, Gauteng, Suth Africa PO Bx 43143, Industria, 2042, Gauteng, Suth Africa Tel N: 27 11 248 8200 Fax N: 27 11 474 2362 www.anchryeast.c.za

More information

OPERATING GUIDELINES Registration Scheduling Pre-season In-season 8:00am on Thursday of the week before Instructional Draft Procedures

OPERATING GUIDELINES Registration Scheduling Pre-season In-season 8:00am on Thursday of the week before Instructional Draft Procedures Apex Parks, Recreatin & Cultural Resurces 2019 SPRING BASEBALL LEAGUE RULES COACH PITCH DIVISION GENERAL: 1. The gal and bjective f the league shall be t prvide enjyment and instructin f the game f cach

More information

REGIONAL ADMINISTRATORS. PATRICK J. KAPUST Acting Director, Directorate of Enforcement Programs DATE: October 19, 2017

REGIONAL ADMINISTRATORS. PATRICK J. KAPUST Acting Director, Directorate of Enforcement Programs DATE: October 19, 2017 MEMORANDUM FOR: REGIONAL ADMINISTRATORS THROUGH: THOMAS GALASSI Acting Deputy Assistant Secretary FROM: PATRICK J. KAPUST Acting Directr, Directrate f Enfrcement Prgrams DATE: Octber 19, 2017 SUBJECT:

More information

Livermore Harley Owners Group RIDING WITH LIVERMORE HOG

Livermore Harley Owners Group RIDING WITH LIVERMORE HOG Livermre Harley Owners Grup RIDING WITH LIVERMORE HOG 2010 Riding with Livermre HOG Table f Cntents Page 1 Welcme Page 2 Ride Planning Page 2 Rad Captains Page 2 Grup Ride Basics Page 3 Grup Riding Prcedures

More information

Winthrop University - Safety in the Chemistry Laboratory

Winthrop University - Safety in the Chemistry Laboratory Winthrp University - Safety in the Chemistry Labratry The Department f Chemistry, Physics, and Gelgy at Winthrp University makes every effrt t prvide a safe learning envirnment fr the chemistry student.

More information

Brazed Plate Heat Exchanger Operating & Instruction Manual U K Exchangers Ltd Unit 55, Stilebrook Road Olney Buckinghamshire MK46 5EA

Brazed Plate Heat Exchanger Operating & Instruction Manual U K Exchangers Ltd Unit 55, Stilebrook Road Olney Buckinghamshire MK46 5EA Brazed Plate Heat Exchanger Operating & Instructin Manual U K Exchangers Ltd Unit 55, Stilebrk Rad Olney Buckinghamshire MK46 5EA Tel: (01234) 244320 Fax: (01234) 714978 Email: sales@ukeltd.cm Web: www.uk-exchangers.cm

More information

PA-65-x Multi-Range Air Differential Pressure Transmitter

PA-65-x Multi-Range Air Differential Pressure Transmitter Date f Issue: 06/01/2015 Page 1 f 5 PA-65-x Multi-Range Air Differential Pressure Transmitter Features: Benefits: Field selectable multi-ranges Field selectable multi-utput Simple 5 step set-up LCD Display

More information

SMALL SIDED FOOTBALL 2012

SMALL SIDED FOOTBALL 2012 Blacktwn Districts Sccer Ftball Assciatin Incrprated. SMALL SIDED FOOTBALL 2012 GUIDELINES FOR CLUB ADMINISTRATORS, SSF CO-ORDINATORS COACH S & REFEREES Nn Cmpetitive & Small Sided Ftball Frmats & Rules

More information

VERSION 1.0 MARKS & SPENCER MARCH 2014 ECP MINIMUM STANDARDS DUE DILIGENCE FOR CHEMICAL COMPLIANCE

VERSION 1.0 MARKS & SPENCER MARCH 2014 ECP MINIMUM STANDARDS DUE DILIGENCE FOR CHEMICAL COMPLIANCE ECP MINIMUM STANDARDS DUE DILIGENCE FOR CHEMICAL COMPLIANCE ENVIRONMENTAL & CHEMICAL POLICY FOR TEXTILE PROCESSING Page 1 f 6 MODULE CONTENT 1 Intrductin... 3 2 Due Diligence Testing... 4 2.1 Prduct testing...

More information

General Industry Toolbox Talks. Providing Excellence in Regulatory Compliance Management Systems

General Industry Toolbox Talks. Providing Excellence in Regulatory Compliance Management Systems General Industry Tlbx Talks Prviding Excellence in Regulatry Cmpliance Management Systems General Industry Tlbx Talks Table f Cntents Why Safety Meetings are Imprtant...- 3 - Guidelines fr Safety Training

More information

Hazard Assessment and Respiratory Protection Reference Guide (OSHA)

Hazard Assessment and Respiratory Protection Reference Guide (OSHA) Hazard Assessment and Respiratry Prtectin Reference Guide (OSHA) This infrmatin is frm the Occupatinal Safety and Health Administratin (sha.gv) What is silica? Silica is a txic respirable dust. Crystalline

More information

Friends Central Aquatics Fall Mini

Friends Central Aquatics Fall Mini Friends Central Aquatics Fall Mini Sunday Nvember 13th, 2011 Held under the sanctin f USA Swimming and Middle Atlantic Swimming Sanctin#: MA 1254 M MEET DIRECTOR: INQUIRIES: MEET LOCATION: Jim Turley:

More information

Winthrop University - Safety in the Chemistry Laboratory

Winthrop University - Safety in the Chemistry Laboratory Winthrp University - Safety in the Chemistry Labratry The Department f Chemistry, Physics, and Gelgy at Winthrp University makes every effrt t prvide a safe learning envirnment fr the chemistry student.

More information

THE UNIVERSITY OF THE WEST INDIES Mona Campus Human Resource Management Division (HRMD) SECTION I GENERAL SAFETY

THE UNIVERSITY OF THE WEST INDIES Mona Campus Human Resource Management Division (HRMD) SECTION I GENERAL SAFETY EOHS 01-011 Persnal Prtective Equipment Intrductin Purpse In sme wrk envirnments Persnal Prtective Equipment (PPE) must be prvided and used t prtect persnnel against hazards capable f causing injury, illness,

More information

Exercise 2: Reviewing the Workplace Inspection Checklist (30 min) p

Exercise 2: Reviewing the Workplace Inspection Checklist (30 min) p Exercise 2: Reviewing the Wrkplace Inspectin Checklist (30 min) p. 19-20 Part One: Behaviurs vs. Cnditins (15 min) Wrking individually: Think f 3 r 4 incidents that have ccurred r have the ptential t ccur

More information

Slim Down and Out Swivel Mount Assembly & Installation Directions

Slim Down and Out Swivel Mount Assembly & Installation Directions Slim Dwn and Out Swivel Munt Assembly & Installatin Directins Munting the Slim Dwn and Out Swivel Munt crrectly takes a lt f thught and a lt f planning. Please read the directins thrughly and plan ut hw

More information

Fall Protection Program Table of Contents

Fall Protection Program Table of Contents Fall Prtectin Prgram Table f Cntents I. Scpe.. Page 2 II. Respnsibilities Page 2 A. Risk Management and Safety. Page 2 B. Departments. Page 3 C. Affected Emplyees. Page 3 III. Fall Hazards. Page 4 A. Ladders

More information

NC Sturgeon Safety Management System

NC Sturgeon Safety Management System Preparatin: Safety Mgr Authrity: President Issuing Dept: Safety Page: Page 1 f 7 Purpse: The purpse f this prgram is t establish requirements fr the use and handling f materials that expse emplyees t cadmium

More information

Black Brant Vb. Please read and understand all instructions before building!

Black Brant Vb. Please read and understand all instructions before building! Black Brant Vb The Black Brandt VB kit cntains all the parts necessary* t build a flying high pwer rcket: (1) Pre-sltted main airframe (1) Nse cne (3) Fins (1) Pistn ejectin kit: (1) Pistn tube (1) Sltted

More information

HUS 6 HUS-S 6. Autoclaved aerated concrete. Description Authority / Laboratory No. / date of issue. IBMB, Braunschweig DIBt, Berlin

HUS 6 HUS-S 6. Autoclaved aerated concrete. Description Authority / Laboratory No. / date of issue. IBMB, Braunschweig DIBt, Berlin Screw anchr HUS 6 / HUS-S 6 Screw anchr Anchr versin Benefits HUS 6 HUS-S 6 Carbn steel Cncrete Screw - Quick and easy setting - Lw expansin frces in base materials - Thrugh fastening - Remvable Cncrete

More information

Core Measure: Functional Gait Assessment (FGA)

Core Measure: Functional Gait Assessment (FGA) Cre Measure: Functinal Gait Assessment (FGA) Overview The FGA is used t assess pstural stability during walking and assesses an individual's ability t perfrm multiple mtr tasks while walking. The tl is

More information

Workflow Description Racket Control WORKFLOW DESCRIPTION CALL AREA AND RACKET CONTROL/TESTING

Workflow Description Racket Control WORKFLOW DESCRIPTION CALL AREA AND RACKET CONTROL/TESTING Wrkflw Descriptin Racket Cntrl WORKFLOW DESCRIPTION CALL AREA AND RACKET CONTROL/TESTING 01.01.2017 1 Wrkflw Descriptin Racket Cntrl Table f Cntents 1. CALL AREA... 3 1.1. Delivery f scre sheet and team

More information

Sponge-Jet Continuous VAC- Recovery System User Manual

Sponge-Jet Continuous VAC- Recovery System User Manual Spnge-Jet Spnge Blasting System Spnge-Jet Cntinuus VAC- Recvery System User Manual Mdel CVR-P110 Headquarters/Manufactured By: Spnge-Jet, Inc. (USA) 14 Pattersn Lane, Newingtn, NH 03801 1-603-610-7950

More information

PS PERSONAL PROTECTIVE EQUIPMENT

PS PERSONAL PROTECTIVE EQUIPMENT PS PERSONAL PROTECTIVE EQUIPMENT PURPOSE AND SCOPE This standard gives instructin n selecting, prviding, fitting, using, strage and dispsal f Persnal Prtective Equipment (PPE) and applies t all persns

More information

Installing the ACT D MAND KONTROLS Systems

Installing the ACT D MAND KONTROLS Systems Installing the ACT D MAND KONTROLS Systems Mdel C1-100-PF fr Standard Piping (Nn-recirculating) Pre-Fab Systems Installatins shall be in accrdance with the manufacturer s instructins per the requirements

More information

E25 FATIGUE MANAGEMENT

E25 FATIGUE MANAGEMENT E25 FATIGUE MANAGEMENT PURPOSE AND SCOPE This Prcedure prvides the requirements and guidance needed t manage fatigue fr Laing O Rurke railway peratins. It will need t be read in cnjunctin with the rail

More information

APCF1 Model Tripod.

APCF1 Model Tripod. APCF1 Mdel Tripd www.ravellipht.cm Prduct Overview The Ravelli APCF1 is a Prfessinal Quality Carbn Fiber Tripd prviding a slid base fr high-end phtgraphic equipment. This mdel is a mix f carbn fiber and

More information